ISO 9001 ISO CABLES AND WIRES CATALOGUE 2008
|
|
|
- Monica Higgins
- 9 years ago
- Views:
Transcription
1 ISO 9001 ISO CABLES AND WIRES CATALOGUE 2008
2 INTRODUCTION... 4 CHAPTER I SINGLE CORE NON-SHEATHED CABLES H05V-U, H05V-R, H05V-K... 6 H05V2-U, H05V2-R, H05V2-K... 7 H07V-U, H07V-R, H07V-K... 8 H07V2-U, H07V2-R, H07V2-K... 9 H05Z-U, H05Z-K H07Z-U, H07Z-R, H07Z-K CHAPTER II FIXED INSTALLATION CABLES NYM-J,O CYKY MMJ (N) YM (ST) - J, -O NHXMH CHAPTER III PVC SHEATHED FLEXIBLE CORDS H03VV-F, H03VVH2-F H05VV-F, H05VVH2-F CHAPTER IV CABLES IN RUBBER H05RR-F H07RN-F NSGAFOU H01N2-D, H01N2-E CHAPTER V HEAT RESISTING SILICONE CABLES SIF SIHF CHAPTER VI POWER AND CONTROL CABLES NYY MMO N2XY AXMK NYCY MCMK AMCMK MCMO N2XH N2XCH FLAME-X 950, (N)HXH FE180/E FLAME-X 950, (N)HXCH FE180/E FLAME-X 950, (N)HXH FE180/E FLAME-X 950, (N)HXCH FE180/E CHAPTER VII MEDIUM AND HIGH VOLTAGE POWER CABLES AHXAMK-W (6/10/(12)) AHXAMK-W (12/20/(24)) TSLE
3 AXCEL AHXCMK-WTC (6/10/(12)) AHXCMK-WTC (12/20/(24)) HXCMK-WTC (6/10/(12)) HXCMK-WTC (12/20/(24)) AHXCMK-WTC (6/10/(12)) AHXCMK-WTC (12/20/(24)) N2XSY, N2XS2Y, NA2XSY, NA2XS2Y N2XS(F)2Y, NA2XS(F)2Y N2XS(FL)2Y, NA2XS(FL)2Y N2XSEY, NA2XSEY, N2XSE2Y, NA2XSE2Y XRUH(A)KXS, N(A)2XS(FL)2Y, TSLE, AXLJ-TT, CU/XLPE/CWS/LT/PE CHAPTER VIII SPECIAL CABLES PAS-W (6/10) PAS-W (12/20) EX AMKA ENAMELLED COPPER WIRE H ENAMELLED COPPER WIRE CX ENAMELLED COPPER WIRE C CHAPTER IX TELECOMUNICATION CABLES VMOHBU TELECOMMUNICATION CABLE MHS TELECOMMUNICATION CABLE KLM TELECOMMUNICATION CABLE KLMA TELECOMMUNICATION CABLE ADDITIONAL INFORMATION
4 INTRODUCTION TELE-FONIKA KABLE is the biggest cable producer in central and eastern europe. In terms of sales, it is europe s fourth biggest cable manufacturer and is noted as one of the world s largest suppliers of cable and wire. The present position of the company is the result of dynamic development supported by the realization of investment projects in , including the acquisition of krakowska fabryka kabli sa (1998) and elektrim kable sa (2002). Over 25,000 different types of cable and wire are produced at the company s plants located in kraków, Our goal is to deliver products of the highest quality at competitive prices. In order to meet customer expectations, international market. 4
5 CHAPTER I SINGLE CORE NON-SHEATHED CABLES
6 PVC INSULATED SINGLE CORE NON-SHEATHED CABLES H05V-U, H05V-R, H05V-K, H05V2-U, H05V2-R, H05V2-K, H07V-U, H07V-R, H07V-K, H07V2-U, H07V2-R, H07V2-K TYPE: H05V-U, H05V-R, H05V-K 300/500 V PVC insulated non sheathed single core cables for internal wiring NORM: HD 21.3, DIN VDE , BS 6004 CONSTRUCTION: Conductor: annealed copper, class 1 solid (H075-U), class 2 stranded (H05V-R) Insulation: PVC compound type TI 1 Colour of insulation: green/yellow, blue, black, brown, grey, orange, pink, red,violet, white, grenn, yellow or other colours Maximum conductor operating temperature: +70 C -30 C -5 C Maximum short-circuit conductor temperature: +160 C Test voltage 50Hz: 2000V Flame propagation: EN (IEC ) Minimum bending radius: 4 x cable diameter The product is conformed with the RoHS Direktive 2002/95/CE, Low-Voltage Direktive 73/23/EEC and 93/68/ECC Application: Fixed protected installation inside appliances and in, or on, lighting conduits, only for signalling or control circuits. Standard length cable packing: 100 m in rings or on spools, or in cardboard boxes. Other forms of packing and delivery are available on request. Nominal crosssectional area of conductor Radial thickness of insulation overall diameter H05V-U 300/500V net weight Maximum resistance of conductor at 20 C Minimum insulation resistance at 70 C mm 2 mm mm kg/km M km 0,5 0,6 2,0 8 36,0 0,014 0,75 0,6 2, ,5 0, ,6 2, ,1 0,011 H05V-R 300/500V* Nominal crosssectional area of conductor Radial thickness of insulation overall diameter net weight Maximum resistance of conductor at 20 C Minimum insulation resistance at 70 C mm 2 mm mm kg/km M km 0,5 0,6 2,1 9 36,0 0,014 0,75 0,6 2, ,5 0, ,6 2, ,1 0,011 SINGLE CORE NON-SHEATHED CABLES 6
7 Nominal crosssectional area of conductor Radial thickness of insulation H05V-K 300/500V overall diameter net weight Maximum resistance of conductor at 20 C Minimum insulation resistance at 70 C mm 2 mm mm kg/km M km 0,5 0,6 2,2 8 39,0 0,013 0,75 0,6 2, ,0 0,011 1 * in standard BS ,6 2, ,5 0,010 TYPE: H05V2-U, H05V2-R, H05V2-K 300/500 V PVC insulated non sheathed single core cables for internal wiring NORM: HD 21.7, DIN VDE , BS 6004 CONSTRUCTION: Conductor: annealed copper, class 1 solid (H052-U), class 2 stranded (H05V2-R) or Insulation: heat resistant PVC compound type TI 3 Colour of insulation: green/yellow, blue, black, brown, grey, orange, pink, red, violet, white, green, yellow or other colours Maximum conductor operating temperature: +90 C -30 C -5 C Maximum short-circuit conductor temperature: +160 C Test voltage 50Hz: 2000V Flame propagation: EN (IEC ) Minimum bending radius: 4 x cable diameter The product is conformed with the RoHS Direktive 2002/95/CE, Low-Voltage Direktive 73/23/EEC and 93/68/ ECC Application: Standard length cable packing: 100 m in rings or on spools, or in cardboard boxes. Other forms of packing and delivery are available on request. Nominal cross-sectional area of conductor H05V2-U 300/500V Radial thickness of insulation overall diameter net weight Maximum resistance of conductor at 20 C mm 2 mm mm kg/km M km 0,5 0,6 2,0 8 36,0 0,015 0,75 0,6 2, ,5 0, ,6 2, ,1 0,011 H05V2-R 300/500V Nominal cross-sectional area of conductor Minimum insulation resistance at 90 C Radial thickness of insulation overall diameter net weight Maximum resistance of conductor at 20 C mm 2 mm mm kg/km M km 0,5 0,6 2,1 8 36,0 0,014 0,75 0,6 2, ,5 0, ,6 2, ,1 0,011 Minimum insulation resistance at 90 C SINGLE CORE NON-SHEATHED CABLES 7
8 Nominal cross-sectional area of conductor H05V2-K 300/500V Radial thickness of insulation overall diameter net weight Maximum resistance of conductor at 20 C mm 2 mm mm kg/km M km 0,5 0,6 2,2 8 39,0 0,013 0,75 0,6 2, ,0 0, ,6 2, ,5 0,010 Minimum insulation resistance at 90 C TYPE: H07V-U, H07V-R, H07V-K 450/750 V PVC insulated non sheathed single core cables for general purposes NORM: HD 21.3, DIN VDE , BS 6004 CONSTRUCTION: Conductor: annealed copper, class 1 solid (H07V-U), class 2 stranded (H07V-R) Insulation: PVC compound type TI 1 Colour of insulation: green/yellow, blue, black, brown, grey, orange, pink, red, violet, white Maximum conductor operating temperature: +70 C -30 C -5 C Maximum short-circuit conductor temperature: +160 C, for cross-section > 300 mm C Test voltage 50Hz: 2500V Flame propagation: EN (IEC ) The product is conformed with the RoHS Direktive 2002/95/CE, Low-Voltage Direktive 73/23/EEC and 93/68/ECC Minimum bending radius: D 8 8 < D < D 20 D > 20 Normal use 4 D 5 D 6 D 6 D Careful bending at termination 2 D 3 D 4 D 4 D Application: installation in surface mounted or embedded conduits, or similar closed controlgear for voltages up to 1000V a.c. or, up to 750V d.c. to earth. Standard length cable packing: 100 m in rings or on spools, or 500 m on drums. Other forms of packing and delivery are available on request. Nominal cross-sectional area of conductor H07V-U 450/750V Radial thickness of insulation overall diameter net weight Maximum resistance of conductor at 20 C mm 2 mm mm kg/km M km 1,5 0,7 2, ,1 0,011 2,5 0,8 3,3 31 7,41 0, ,8 3,8 45 4,61 0, ,8 4,3 64 3,08 0, ,0 5, ,83 0,0072 Minimum insulation resistance at 70 C SINGLE CORE NON-SHEATHED CABLES 8
9 Nominal cross-sectional area of conductor H07V-R 450/750V Radial thickness of insulation overall diameter net weight Maximum resistance of conductor at 20 C mm 2 mm mm kg/km M km 1,5 0,7 2, ,1 0,010 2,5 0,8 3,6 33 7,41 0, ,8 4,1 48 4,61 0, ,8 4,5 66 3,08 0, ,0 5, ,83 0, ,0 6, ,15 0, ,2 8, ,727 0, ,2 9, ,524 0, ,4 11, ,387 0, ,4 12, ,268 0, ,6 14, ,193 0, ,6 16, ,153 0, ,8 18, ,124 0, ,0 20, ,0991 0, ,2 23, ,0754 0, ,4 26, ,0601 0, ,6 30, ,0470 0,0031 H07V-K 450/750V Nominal cross-sectional area of conductor Minimum insulation resistance at 70 C Radial thickness of insulation overall diameter net weight Maximum resistance of conductor at 20 C mm 2 mm mm kg/km M km 1,5 0,7 2, ,3 0,010 2,5 0,8 3,6 31 7,98 0, ,8 4,1 45 4,95 0, ,8 4,6 63 3,30 0, ,0 6, ,91 0, ,0 7, ,21 0, ,2 8, ,780 0, ,2 9, ,554 0, ,4 11, ,386 0, ,4 13, ,272 0, ,6 16, ,206 0, ,6 17, ,161 0, ,8 19, ,129 0, ,0 22, ,106 0, ,2 24, ,0801 0,0031 TYPE: H07V2-U, H07V2-R, H07V2-K 450/750 V Heat resisting PVC insulated non sheathed single core cable for internal wiring NORM: PN-HD 21.7, DIN VDE , BS 6004 CONSTRUCTION: Conductor: annealed copper, class 1 solid (H07V2-U), class 2 stranded (H07V2-R) or class Insulation: heat resisting PVC compound type TI 3 Minimum insulation resistance at 70 C Colour of insulation: green/yellow, blue, black, brown or other colours Maximum conductor operating temperature: +90 C -30 C -5 C SINGLE CORE NON-SHEATHED CABLES 9
10 Maximum short-circuit conductor temperature: +160 C Test voltage 50Hz: 2500V Flame propagation: EN (IEC ) The product is conformed with the RoHS Direktive 2002/95/CE, Low-Voltage Direktive 73/23/EEC and 93/68/ECC Minimum bending radius: D 8 8 < D < D 20 D > 20 Normal use 4 D 5 D 6 D 6 D Careful bending at termination 2 D 3 D 4 D 4 D Application: Standard length cable packing: Nominal cross-sectional area of conductor protected installation in, or on, lighting or controlgear for voltages up to 1000V a.c. or, up to 750V d.c. to earth. 100 m in rings or on spools, or 500 m on drums. Other forms of packing and delivery are available on request. mm 2 mm mm kg/km 1,5 0,7 2, ,1 2,5 0,8 3,3 30 7,41 H07V2-R 450/750V Nominal cross-sectional area of conductor Radial thickness of insulation overall diameter net weight Maximum resistance of conductor at temperature 20 C mm 2 mm mm kg/km 1,5 0,7 3, ,1 2,5 0,8 3,6 32 7,41 4 0,8 4,1 47 4,61 6 0,8 4,5 64 3, ,0 5, , ,0 6, , ,2 8, , ,2 9, ,524 07V2-R 450/750V 50* 1,4 11, ,387 70* 1,4 12, ,268 95* 1,6 15, , * 1,6 16, , * 1,8 18, , * 2,0 20, , * 2,2 23, ,0754 H07V2-K 450/750V Nominal cross-sectional area of conductor Radial thickness of insulation Radial thickness of insulation H07V2-U 450/750V overall diameter overall diameter net weight net weight Maximum resistance of conductor at temperature 20 C Maximum resistance of conductor at temperature 20 C mm 2 mm mm kg/km 1,5 0,7 2, ,3 2,5 0,8 3,6 30 7,98 4 0,8 4,1 43 4,95 6 0,8 4,6 61 3, ,0 6, , ,0 7, , ,2 8, , ,2 9, ,554 07V2-K 450/750V 50* 1,4 11, ,386 70* 1,4 13, ,272 95* 1,6 16, , * 1,6 17, , * 1,8 19, , * 2,0 22, , * 2,2 24, ,0801 * 07V2-R and 07V2-K adapted to HD 21.3 and HD 21.7 SINGLE CORE NON-SHEATHED CABLES 10
11 LOW SMOKE HALOGEN FREE SINGLE CORE NON-SHEATHED CABLES H05Z-U, H05Z-K, H07Z-U, H07Z-R, H07Z-K TYPE: H05Z-U, H05Z-K 300/500 V Thermosetting insulated, non-sheathed, single core cables with low emission of smoke and corrosive gases NORM: HD 22.9, DIN VDE , BS 7211 CONSTRUCTION: Conductor: Insulation: Colour of insulation: EN green/yellow, black, blue, brown, grey, orange, pink, red, white or other colours. Maximum conductor operating temperature: +90 C -5 C Maximum short-circuit temperature: +250 C Test voltage 50Hz: 2000V Minimum bending radius: 4 x D, D cable overall diameter PERFORMANCE UNDER FIRE CONDITIONS Flame propagation: EN (IEC ) Smoke emission: EN (IEC ) Corrosive and acid gas emission of insulation: The product is conformed with the RoHS Direktive 2002/95/CE, Low-Voltage Direktive 73/23/EEC and 93/68/ECC Application: Standard length cable packing: Nominal cross-sectional area of conductor particularly for situations in which low emission of smoke and corrosive gases is required in the case of burning. Suitable for installation in surface mounted or embedded conduits, only for signalling or control circuits. 100 m in coils or on spools. Other forms of packing and delivery are available on request. H05Z-U Thickness Maximum resistance of conductor at 20 o C of insulation overall diameter net weight mm 2 mm mm kg/km /km 0,5 0,6 2,0 8 36,0 0,75 0,6 2, ,5 1 0,6 2, ,1 H05Z-K Nominal cross-sectional area of conductor Thickness of insulation overall diameter net weight mm 2 mm mm kg/km /km 0,5 0,6 2,1 8 39,0 0,75 0,6 2, ,0 1 0,6 2, ,5 Maximum resistance of conductor at 20 o C SINGLE CORE NON-SHEATHED CABLES 11
12 TYPE: H07Z-U, H07Z-R, H07Z-K 450/750 V Thermosetting insutated, non-sheathed, single core cables with low emission of smoke and corrosive gases NORM: HD 22.9, DIN VDE , BS 7211 CONSTRUCTION: Conductor: Insulation: annealed copper, class 1 solid (H07Z-U), class 2 stranded Colour of insulation: green/yellow, black, blue, brown, grey, orange, pink, red, white or other colours. Maximum conductor operating temperature: +90 C -40 o C -5 C Maximum short-circuit temperature: +250 C Test voltage 50Hz: 2500V Minimum bending radius: D 8 8 < D < D 20 D > 20 Normal use 4 D 5 D 6 D 6 D Careful bending at termination 2 D 3 D 4 D 4 D PERFORMANCE UNDER FIRE CONDITIONS Flame propagation: EN (IEC ) Smoke emission:en (IEC ): Light transmittance > 70% Corrosive and acid gas emission of insulation: EN (IEC ): ph conductivity: 10 S/mm The product is conformed with the RoHS Direktive 2002/95/CE, Low-Voltage Direktive 73/23/EEC and 93/68/ECC Application: Single core, non-sheathed cables are suitable particularly for situations in which low emission of smoke and corrosive gases is required in the case of burning. H07Z-U, H07Z-R, H07Z-K - single core, non-sheathed cables are intended for installation in surface mounted or embedded installation in or on, lighting and control gear for voltages up to 1000 V a.c. or, up to 1.5 times higher for d.c. usage. Standard length cable packing: 100 m in coils or on spools, or 500 m on drums. Other forms of packing and delivery are available on request. H07Z-U 450/750V Radial thickness overall net of insulation diameter weight mm 2 mm mm kg/km /km 1,5 0,7 2, ,1 2,5 0,8 3,3 30 7,41 4 0,8 3,8 45 4,61 6 0,8 4,3 63 3, ,0 5, ,83 Nominal cross-sectional area of conductor Maximum resistance of conductor at temperature 20 C SINGLE CORE NON-SHEATHED CABLES 12
13 H07Z-R 450/750V Radial thickness overall net of insulation diameter weight mm 2 mm mm kg/km /km 1,5 0,7 3, ,1 2,5 0,8 3,6 32 7,41 4 0,8 4,1 48 4,61 6 0,8 4,5 65 3, ,0 5, , ,0 6, , ,2 8, , ,2 9, , ,4 11, , ,4 12, , ,6 15, , ,6 16, , ,8 18, , ,0 20, , ,2 23, , ,4 25, , ,6 29, ,0470 H07Z-K 450/750V Nominal cross-sectional area of conductor Nominal cross-sectional area of conductor Radial thickness of insulation overall diameter net weight Maximum resistance of conductor at temperature 20 C Maximum resistance of conductor at temperature 20 C mm 2 mm mm kg/km /km 1,5 0,7 2, ,3 2,5 0,8 3,6 30 7,98 4 0,8 4,1 44 4,95 6 0,8 4,6 62 3, ,0 6, , ,0 7, , ,2 8, , ,2 9, , ,4 11, , ,4 13, , ,6 16, , ,6 17, , ,8 19, , ,0 22, , ,2 24, , * 2,4 28, , * 2,6 30, ,0486 * Not in standard, type 07V-K SINGLE CORE NON-SHEATHED CABLES 13
14 14
15 CHAPTER II FIXED INSTALLATION CABLES 15
16 UNSCREENED FIXED INSTALLATION CABLES NYM-J, NYM-O, CYKY-J, MMJ TYPE: NYM-J,O 300/500 V PVC-sheathed cables for power installation NORM: DIN VDE CONSTRUCTION: Conductor: solid or stranded plain copper acc. to DIN EN Insulation: PVC compound type TI1 Filling: Sheath: PVC compound type TM1 Colour of sheath: grey RAL 7035 acc to DIN VDE with protective conductor-j without protective conductor-0 single-core green/yellow black twin - blue, brown 3-core green/yellow, blue, brown brown, black, grey 4-core green/yellow, brown, black, grey blue, brown, black, grey 5-core green/yellow, blue, brown, black, grey blue, brown, black, grey, black 7-core and more green/yellow, other cores black with white numbering black with white numbering Maximum conductor operating temperature: +70 C -30 o C -5 o C Maximum short-circuit conductor temperature: +160 o C Flame propagation: DIN EN Test voltage 50Hz: 2000V Minimum bending radius: 6 x cable diameter. The product is conformed with the RoHS Direktive 2002/95/CE, Low-Voltage Direktive 73/23/EEC and 93/68/ECC Application: Standard length cable packing: and concealed, as well as in masonry and in concrete, not suitable for imbedding in is protected against direct sunlight m coils or 500 m on drums. Other forms of packing and delivery are available on request.. FIXED INSTALLATION CABLES 16
17 Number and crosssectional area of conductor Nominal thickness of insulation Nominal thickness of sheath NYM 300/500 V overall diameter net weight Maximum conductor resistance at 20 C n x mm 2 mm mm mm kg/km /km 1 x 1,5 0,6 1,4 5, ,1 1 x 2,5 0,7 1,4 5,9 60 7,41 1x4 0,8 1,4 6,6 80 4,61 1x6 0,8 1,4 7, ,08 1x10 1,0 1,4 8, ,83 1x16 1,0 1,4 9, ,15 2 x 1,5 0,6 1,4 8, ,1 2 x 2,5 0,7 1,4 9, ,41 2x4 0,8 1,4 10, ,61 2x6 0,8 1,4 11, ,08 2x10 1,0 1,6 14, ,83 2x16 1,0 1,6 17, ,15 2x25 1,2 1,6 21, ,727 2x35 1,2 1,8 23, ,524 3 x 1,5 0,6 1,4 8, ,1 3 x 2,5 0,7 1,4 10, ,41 3x4 0,8 1,4 11, ,61 3x6 0,8 1,6 12, ,08 3x10 1,0 1,6 15, ,83 3x16 1,0 1,6 18, ,15 3x25 1,2 1,8 22, ,727 3x35 1,2 1,8 25, ,524 4 x 1,5 0,6 1,4 9, ,1 4 x 2,5 0,7 1,4 10, ,41 4x4 0,8 1,6 12, ,61 4x6 0,8 1,6 14, ,08 4x10 1,0 1,6 17, ,83 4x16 1,0 1,6 20, ,15 4x25 1,2 1,8 25, ,727 4x35 1,2 1,8 27, ,524 5 x 1,5 0,6 1,4 10, ,1 5 x 2,5 0,7 1,4 11, ,41 5x4 0,8 1,6 14, ,61 5x6 0,8 1,6 15, ,08 5x10 1,0 1,6 18, ,83 5x16 1,0 1,8 22, ,15 5x25 1,2 1,8 27, ,727 5x35 1,2 1,8 30, ,524 7 x 1,5 0,6 1,4 10, ,1 7 x 2,5 0,7 1,6 13, ,41 8 x 1,5* 0,6 1,4 11, ,1 10 x 1,5* 0,6 1,4 13, ,1 12 x 1,5* 0,6 1,4 14, ,1 12 x 2,5* * Adapted to DIN VDE ,7 1,6 16, ,41 Current ratings acc. to DIN VDE 0298 Part 4 Installation: - in thermally insulated walls - in insulating tubes Number of loaded cores Cross-section (mm 2 ) Multicore sheathed cables in insulating tubes, in a thermally insulated walls Multicore sheathed cables in insulating tubes on e wall Single or multicore sheathed cables on a wall Multicore sheathed cables with a space of minimum 0,3 x diameter d to wall 2 3 1) 2 3 1) 2 3 1) 2 3 1) Current ratings in Ampere (A) 1,5 15,5 13,0 16,5 15,0 19,5 17, ,5 2,5 18,5 17, FIXED INSTALLATION CABLES 17
18 Permissible operating temperature at conductor: 70 C Ambient temperature: 30 o C Conversion factors for ambient temperature over 30 C Ambient temperature, ºC Conversion factors 1,00 0,94 0,87 0,79 0,71 0,61 0,50 0,35 1) Conversion factors for multicore cable ( 5 cores) Number of loaded cores Conversion factors 5 0,75 7 0, , ,50 TYPE: CYKY 450/750 V PVC insulated and PVC sheathed power cables NORM: CSN and CSN CONSTRUCTION: Conductor: solid from copper soft wires class 1 - IEC Insulation: PVC type TI1 Inner covering: Outer sheath: Colour of sheath: PVC type TM1i Black CSN or HD 308 Dielectric test voltage 50Hz: 2,5kV Max temperature of conductor during cable operation: +70 o C Operating temperature: -15 o Cupto+70 o C Min ambient temperature at laying of cables: -5 o C Max temperature of conductor at short-circuit: +150 o C Min bending radius: 10 x D outer diameter of cable IEC Standard packing Number and cross sectional area of conductor Drums 500 or 1000 m. Other lengths and types of packing may be offered on request CYKY 450/750V Nominal Nominal Number of wires in thickness thickness overall net conductor of insulation of sheath diameter weight nxmm 2 mm mm mm mm kg/km 2 x 1,5 1 0,80 1,00 8, ,1 2 x 2,5 1 0,90 1,00 9, ,41 2x4 1 1,00 1,00 10, ,61 3 x 1,5 1 0,80 1,00 8, ,1 3 x 2,5 1 0,90 1,00 10, ,41 3x4 1 1,00 1,20 11, ,61 3x6 1 1,00 1,20 13, ,08 Maximum resistance of conductor at temperature 20 C FIXED INSTALLATION CABLES 18
19 Number and cross sectional area of conductor Number of wires in conductor Nominal thickness of insulation CYKY 450/750V Nominal thickness of sheath overall diameter net weight Maximum resistance of conductor at temperature 20 C nxmm 2 mm mm mm mm kg/km 4 x 1,5 1 0,80 1,00 9, ,1 4 x 2,5 1 0,90 1,00 11, ,41 4x4 1 1,00 1,20 12, ,61 4x6 1 1,00 1,20 14, ,08 4x10 1 1,00 1,20 16, ,83 4x16 1 1,00 1,40 19, ,15 5 x 1,5 1 0,80 1,00 10, ,1 5 x 2,5 1 0,90 1,20 12, ,41 5x4 1 1,00 1,20 13, ,61 5x6 1 1,00 1,20 15, ,08 5x10 1 1,00 1,40 17, ,83 5x16 1 1,00 1,40 21, ,15 7 x 1,5 1 0,80 1,20 11, ,1 7 x 2,5 1 0,90 1,20 13, ,41 12 x 1,5 1 0,80 1,20 15, ,1 12 x 2,5 1 0,90 1,40 18, ,41 19 x 1,5 1 0,80 1,40 18, ,1 19 x 2,5 1 0,90 1,40 21, ,41 24 x 1,5 1 0,80 1,40 21, ,1 24 x 2,5 1 0,90 1,60 24, ,41 37 x 1,5 1 0,80 1,60 24, ,1 TYPE: MMJ 300/500 V and 450/750 V PVC-sheathed cables for power installation NORM: HD 21.4 S2 and SFS 2091 CONSTRUCTION: Conductor: Insulation: Filling: Sheath: Colour of sheath: solid class 1for 1,5 and 2,5 mm 2, the other cross-sectional area stranded class 2 plain copper acc. to EN special PVC compound type TI1 special PVC compound type TM1 white QCC. to HD 308 S2 twin - blue, brown 3-core green/yellow, blue, brown brown, black, grey 4-core green/yellow, brown, black, grey blue, brown, black, grey 5-core green/yellow, blue, brown, black, grey blue, brown, black, grey, black Maximum conductor operating temperature: +70 C Lowest recommended temperature during laying: -15 o C Maximum short-circuit conductor temperature: +160 o C Flame retardant: EN Minimum bending radius: 10 x cable diameter The product is conformed with the RoHS Direktive 2002/95/CE, Low-Voltage Direktive 73/23/EEC and 93/68/ECC Application: installation at low temperature. Standard length cable packing: 100 m coils or 500 m on drums. Other forms of packing and delivery are available on request. FIXED INSTALLATION CABLES 19
20 Number and crosssectional area of conductor Nominal thickness of insulation MMJ 300/500V acc. to HD 21.4 and SFS 2091 Nominal thickness of sheath overall diameter net weight Maximum conductor resistance at 20 C nxmm 2 mm mm mm kg/km 2 x 1,5 0,7 1,2 8, ,1 2 x 2,5 0,8 1,2 9, ,41 3 x 1,5 0,7 1,2 9, ,1 3 x 2,5 0,8 1,2 10, ,41 3 x 4 0,8 1,2 12, ,61 4 x 1,5 0,7 1,2 9, ,1 4 x 2,5 0,8 1,2 11, ,41 4 x 4 0,8 1,4 13, ,61 5 x 1,5 0,7 1,2 10, ,1 5 x 2,5 0,8 1,2 12, ,41 5 x 4 0,8 1,4 15, ,61 5 x 6 0,8 1,4 16, ,08 5 x 10 1,0 1,4 19, ,83 5 x 16 1,0 1,6 23, ,15 MMJ 450/750V acc. to SFS x 4 0,8 1,5 12, ,61 2 x 6 0,8 1,5 12, ,08 2 x 10 1,0 1,5 15, ,83 2 x 16 1,0 1,6 18, ,15 2 x 25 1,2 1,6 21, ,727 2 x 35 1,2 1,7 24, ,524 3 x 4 0,8 1,5 12, ,61 3 x 6 0,8 1,5 13, ,08 3 x 10 1,0 1,5 16, ,83 3 x 16 1,0 1,6 19, ,15 3 x 25 1,2 1,7 23, ,727 3 x 35 1,2 1,7 25, ,524 4 x 4 0,8 1,5 13, ,61 4 x 6 0,8 1,5 15, ,08 4 x 10 1,0 1,6 18, ,83 4 x 16 1,0 1,7 21, ,15 4 x 25 1,2 1,7 25, ,727 4 x 35 1,2 1,8 28, ,524 5 x 4 0,8 1,5 15, ,61 5 x 6 0,8 1,5 16, ,08 5 x 10 1,0 1,7 20, ,83 5 x 16 1,0 1,7 23, ,15 5 x 25 1,2 1,8 28, ,727 5 x 35 1,2 1,8 31, ,524 FIXED INSTALLATION CABLES 20
21 SCREENED FIXED INSTALLATION CABLES (N) YM (St) TYPE: (N) YM (St) - J, -O 300/500 V PVC-sheathed screened cables for power installation NORM: Adapted to DIN VDE / 209 CONSTRUCTION: Conductor: solid or stranded plain copper acc. to DIN EN Insulation: PVC compound type TI1 Screen: Drain wire: Sheath: coated aluminium foil solid tinned copper wire PVC compound type TM1 Colour of sheath: grey RAL 7035 acc to DIN VDE twin blue, brown 3-core green/yellow, blue, brown 4-core green/yellow, brown, black, grey 5-core green/yellow, blue, brown, black, grey 7-core green/yellow, other cores black with white numbering Maximum conductor operating temperature: +70 C -30 o C -5 o C Maximum short-circuit conductor temperature: +160 o C Flame propagation: DIN EN ( IEC ) Minimum bending radius: 6 x cable diameter The product is conformed with the RoHS Direktive 2002/95/CE, Low-Voltage Direktive 73/23/EEC and 93/68/ECC Application: These cables with screening are also ideal for installations in the living rooms of those peoples who are extreme sensitive to radiation in computer sector, hospitals etc. The cable is suitable for laying on, in and under plaster in dry and damp places as wall as in concrete and masonry. Standard length cable packing: 100 m coils or 500 m on drums. Other forms of packing and delivery are available on request. FIXED INSTALLATION CABLES 21
22 (N) YM (St) 300/500 Nominal thickness Nominal thickness of insulation of sheath overall diameter net weight nxmm 2 mm mm mm kg/km 2 x 1,5/1,5 0,6 1,4 8, ,1 / 12,1 2 x 2,5/1,5 0,7 1,4 9, ,41 / 12,1 2 x 4 /1,5 0,8 1,4 10, ,61 / 12,1 2 x 6 /1,5 0,8 1,4 11, ,08 / 12,1 3 x 1,5/1,5 0,6 1,4 8, ,1 / 12,1 3 x 2,5/1,5 0,7 1,4 9, ,41 / 12,1 3 x 4 /1,5 0,8 1,4 11, ,61 / 12,1 3 x 6 /1,5 0,8 1,6 12, ,08 / 12,1 4 x 1,5/1,5 0,6 1,4 9, ,1 / 12,1 4 x 2,5/1,5 0,7 1,4 10, ,41 / 12,1 4 x 4 /1,5 0,8 1,6 12, ,61 / 12,1 4 x 6 /1,5 0,8 1,6 13, ,08 / 12,1 5 x 1,5/1,5 0,6 1,4 10, ,1 / 12,1 5 x 2,5/1,5 0,7 1,4 11, ,41 / 12,1 5 x 4 /1,5 0,8 1,6 13, ,61 / 12,1 5 x 6 /1,5 0,8 1,6 14, ,08 / 12,1 5 x 10/1,5 1,0 1,6 18, ,83 / x 1,5/1,5 0,6 1,4 10, ,1 / 12,1 Number and cross-sectional area of conductor Current ratings acc. to DIN VDE 0298 Part 4 Maximum conductor resistance at 20 C Installation: Number of loaded cores Cross-section (mm 2 ) Multicore sheathed cables in insulating tubes, in a thermally insulated walls Multicore sheathed cables in insulating tubes on e wall Single or multicore sheathed cables on a wall Multicore sheathed cables with a space of minimum 0,3 x diameter d to wall 2 3 1) 2 3 1) 2 3 1) 2 3 1) Current ratings in Ampere (A) 1,5 15,5 13,0 16,5 15,0 19,5 17, ,5 2,5 18,5 17, Permissible operating temperature at conductor: 70 C. Ambient temperature: 30 o C 1) Conversion factors for multicore cable ( 5 cores) Number of loaded cores Conversion factors 5 0,75 7 0,65 FIXED INSTALLATION CABLES 22
23 LOW SMOKE HALOGEN FREE FIXED INSTALLATION CABLES NHXMH-J, NHXMH-O TYPE: NHXMH 300/500 NORM: DIN VDE CONSTRUCTION: Conductor: solid or stranded plain copper acc. to DIN EN Insulation: Filling: Sheath: cross-linked polyethylene XLPE halogen-free special halogen-free thermoplastic compound acc to DIN VDE with protective conductor-j without protective conductor-0 single-core green/yellow black twin - blue, brown 3-core green/yellow, blue, brown brown, black, grey 4-core green/yellow, brown, black, grey blue, brown, black, grey 5-core green/yellow, blue, brown, black, grey blue, brown, black, grey, black 7-core and more green/yellow, other cores black with white numbering black with white numbering Maximum conductor operating temperature: +70 C -30 o C -5 o C Maximum short-circuit conductor temperature: +250 o C Flame retardant: DIN VDE C, DIN EN , IEC Category C Smoke density: VDE , IEC : light transmittance values > 70% Gases evolved during combustion: VDE , IEC : ph 100 S/cm Minimum bending radius: for single core cables: 15 x cable diameter, for multi-core cables: 10 x cable diameter The product is conformed with the RoHS Direktive 2002/95/CE, Low-Voltage Direktive 73/23/EEC and 93/68/ECC Application: Installation cables for industrial complexes, public buildings, hotels, airports, hospitals or industrial plants with high concentration of people and/or property. Usable in the open, in dry, damp and wet environments in the open and concealed, as well as in masonry and in Standard length cable packing: 100 m coils or 500 m on drums. Other forms of packing and delivery are available on request. Number and crosssectional area of conductor Nominal thickness of insulation Nominal thickness of sheath NHXMH 300/500 V overall diameter net weight Maximum conductor resistance at 20 C Caloric load nxmm 2 mm mm mm kg/km kwh/m 1 x 1,5 0,5 1,4 5, ,1 0,33 1 x 2,5 0,5 1,4 5,5 52 7,41 0,36 1 x 4 0,6 1,4 6,2 71 4,61 0,42 1x6 0,6 1,4 6,7 92 3,08 0,44 1 x 10 0,7 1,4 7, ,83 0,53 1 x 16 0,7 1,4 9, ,15 0,64 FIXED INSTALLATION CABLES 23
24 NHXMH 300/500 V Number and crosssectional area of Nominal thickness Nominal thickness overall Maximum conductor of insulation of sheath diameter net weight resistance at 20 C conductor Caloric load nxmm 2 mm mm mm kg/km kwh/m 2 x 1,5 0,5 1,4 8, ,1 0,36 2 x 2,5 0,5 1,4 8, ,41 0,42 2 x 4 0,6 1,4 10, ,61 0,56 2x6 0,6 1,4 11, ,08 0,64 2 x 10 0,7 1,6 13, ,83 0,97 2 x 16 0,7 1,6 16, ,15 1,3 2 x 25 0,9 1,6 19, ,727 1,8 2 x 35 0,9 1,8 22, ,524 2,3 3 x 1,5 0,5 1,4 8, ,1 0,42 3 x 2,5 0,5 1,4 9, ,41 0,47 3 x 4 0,6 1,4 10, ,61 0,61 3x6 0,6 1,6 12, ,08 0,78 3 x 10 0,7 1,6 14, ,83 1,1 3 x 16 0,7 1,6 17, ,15 1,5 3 x 25 0,9 1,8 21, ,727 2,1 3 x 35 0,9 1,8 24, ,524 2,5 4 x 1,5 0,5 1,4 9, ,1 0,47 4 x 2,5 0,5 1,4 10, ,41 0,56 4 x 4 0,6 1,6 12, ,61 0,78 4x6 0,6 1,6 13, ,08 0,94 4 x 10 0,7 1,6 15, ,83 1,3 4 x 16 0,7 1,6 19, ,15 1,8 4 x 25 0,9 1,8 23, ,727 2,6 4 x 35 0,9 1,8 26, ,524 3,1 5 x 1,5 0,5 1,4 9, ,1 0,56 5 x 2,5 0,5 1,4 10, ,41 0,64 5 x 4 0,6 1,6 13, ,61 0,98 5x6 0,6 1,6 14, ,08 1,1 5 x 10 0,7 1,6 17, ,83 1,5 5 x 16 0,7 1,8 21, ,15 2,2 5 x 25 0,9 1,8 25, ,727 3,1 5 x 35 0,9 1,8 29, ,524 3,7 7 x 1,5 0,5 1,4 10, ,1 0,64 7 x 2,5 0,5 1,6 12, ,41 0,81 Current ratings acc. to DIN VDE 0298 Part 4 Installation: - in thermally insulated walls - in insulating tubes Multicore sheathed cables in insulating tubes, in a thermally insulated walls Multicore sheathed cables in insulating tubes on e wall Single or multicore sheathed cables on a wall Multicore sheathed cables with a space of minimum 0,3 x diameter d to wall Number of loaded cores 2 3 1) 2 3 1) 2 3 1) 2 3 1) Cross-section (mm 2 ) Current ratings in Ampere (A) 1,5 15,5 13,0 16,5 15,0 19,5 17, ,5 2,5 18,5 17, Permissible operating temperature at conductor: 70 C Ambient temperature: 30 o C Conversion factors for ambient temperature over 30 C Ambient temperature, ºC Conversion factors 1,00 0,94 0,87 0,79 0,71 0,61 0,50 0,35 1) Conversion factors for multicore cable ( 5 cores) Number of loaded cores Conversion factors 5 0,75 7 0,65 FIXED INSTALLATION CABLES 24
25 CHAPTER III PVC SHEATHED FLEXIBLE CORDS 25
26 PVC SHEATHED FLEXIBLE CORDS H03VV-F, H03VVH2-F, H05VV-F, A05VV-F, H05VVH2-F, TYPE: H03VV-F 300/300V H03VVH2-F 300/300V NORM: DIN VDE , BS 6500, NFC , PN-HD 21.5 CONSTRUCTION: Conductor: Insulation: Sheath: PVC type TI2 PVC type TM2 twin core 3-core 4-core blue and brown green/yellow, blue and brown green/yellow, brown, black, grey Maximum conductor operating temperature: +70 C -30 o C Lowest installation temperature: +5 o C Maximum short-circuit conductor temperature: +150 o C Test voltage 50Hz: 2000V Flame retardant: EN ( IEC ) Minimum bending radius: 6 x cable diameter The product is conformed with the RoHS Direktive 2002/95/CE, Low-Voltage Direktive 73/23/EEC and 93/68/ECC Application: Number and crosssectional area of conductor Nominal thickness of insulation Nominal thickness of sheath overall diameter onductor cross-section [mm 2 ] Single phase Current rating [A] Three phase 0, , These values apply to the majority of cases. Further information should be sought in unusual cases eg.: when high ambient temperatures are involved, ie. above 30 o C where long lengths are used where ventilation is restricted where the cords are used for other purposes, eg. internal wiring of apparatus. net weight of cables Maximum conductor resistance at 20 o C nxmm 2 mm mm mm kg/km H03VV-F 2x0,5 0,5 0,6 5, ,0 2x0,75 0,5 0,6 5, ,0 3x0,5 0,5 0,6 5, ,0 3x0,75 0,5 0,6 5, ,0 4x0,5 0,5 0,6 5, ,0 4x0,75 0,5 0,6 6, ,0 H03VVH2-F 2x0,5 0,5 0,6 3,1x5, ,0 2x0,75 0,5 0,6 3,3x5, ,0 PVP SHEATHED FLEXIBLE CORDS 26
27 TYPE: H05VV-F 300/500V H05VVH2-F 300/500V NORM: DIN VDE , BS 6500, BS 7919, NFC , PN-HD 21.5 CONSTRUCTION: Conductor: Insulation: Sheath: PVC type TI2 PVC type TM2 twin core 3-core 4-core 5-core blue and brown green/yellow, blue and brown green/yellow, brown, black, grey green/yellow, blue, brown, black, grey Maximum conductor operating temperature: +70 C -30 o C Lowest installation temperature: +5 o C Maximum short-circuit conductor temperature: +150 o C Test voltage 50Hz: 2000V Flame retardant: EN ( IEC ) Minimum bending radius: 6 x cable diameter The product is conformed with the RoHS Direktive 2002/95/CE, Low-Voltage Direktive 73/23/EEC and 93/68/ECC Application: refrigerators). Number and crosssectional area of conductor Nominal thickness of insulation Nominal thickness of sheath H05VV-F overall diameter net weight of cables Maximum conductor resistance at 20 o C nxmm 2 mm mm mm kg/km 2x0,75 0,6 0,8 6, ,0 2x1 0,6 0,8 6, ,5 2x1,5 0,7 0,8 7, ,3 2x2,5 0,8 1,0 9, ,98 2x4 0,8 1,1 10, ,95 3x0,75 0,6 0,8 6, ,0 3x1 0,6 0,8 6, ,5 3x1,5 0,7 0,9 8, ,3 3x2,5 0,8 1,1 9, ,98 3x4 0,8 1,2 11, ,95 4x0,75 0,6 0,8 7, ,0 4x1 0,6 0,9 7, ,5 4x1,5 0,7 1,0 9, ,3 4x2,5 0,8 1,1 10, ,98 4x4 0,8 1,2 12, ,95 5x0,75 0,6 0,9 8, ,0 5x1 0,6 0,9 8, ,5 5x1,5 0,7 1,1 10, ,3 5x2,5 0,8 1,2 12, ,98 5x4 0,8 1,4 13, ,95 H05VVH2-F 2x0,75 0,6 0,8 3,9x6, ,0 2x1 0,6 0,8 4,0x6, ,5 PVP SHEATHED FLEXIBLE CORDS 27
28 Conductor cross-section [mm 2 ] Single phase Current rating [A] Three phase 0, , , , These values apply to the majority of cases. Further information should be sought in unusual cases eg.: when high ambient temperatures are involved, ie. above 30 o C where long lengths are used where ventilation is restricted where the cords are used for other purposes, eg. internal wiring of apparatus. PVP SHEATHED FLEXIBLE CORDS 28
29 CHAPTER IV CABLES IN RUBBER 29
30 CABLES IN RUBBER H05RR-F, H07RN-F, NSGAFOU TYPE: H05RR-F 300/500V NORM: DIN VDE , BS 6500, BS 7919, NF C , HD 22.4 S3 CONSTRUCTION: Conductor: Insulation: Sheath: Colour of sheath: EPR rubber type EI4 rubber compound type EM3 black acc. to HD 308 S2 and BS 6500, BS 7919 twin core blue and brown 3-core green/yellow, blue and brown 4-core green/yellow, brown, black, grey 4 core* green/yellow, blue, brown, black 5 - core * For certain applications only. green/yellow, blue, brown, black, grey Test voltage 50Hz: 2000V Maximum conductor operating temperature: + 60 o C -30 o C Lowest installation temperature: -25 o C Maximum short-circuit conductor temperature: +200 o C Minimum bending radius: 7,5 x D, D overall diameter of cable Flame propagation: EN , (IEC ) The product is conformed with the RoHS Direktive 2002/95/CE, Low-Voltage Direktive 73/23/EEC and 93/68/ECC Application: where the cables are subjected to low mechanical stresses (eg. vacuum cleaners, cooking appliances, soldering irons, toasters). Standard length cable packing: 100 m in coils and 500 or 1000 m on drums. Other forms of packing and delivery are available on request. Number and crosssectional area f conductor Nominal thickness of insulation Nominal thickness of sheath overall diameter net weight Maximum resistance of conductor at 20 C nxmm 2 mm mm mm kg/km 2x0,75 0,6 0,8 6, ,7 2x1 0,6 0,9 6, ,0 2x1,5 0,8 1,0 8, ,7 2x2,5 0,9 1,1 9, ,21 3x0,75 0,6 0,9 6, ,7 3x1 0,6 0,9 6, ,0 3x1,5 0,8 1,0 8, ,7 3x2,5 0,9 1,1 10, ,21 3x4 1,0 1,2 12, ,09 3x6 1,0 1,4 13, ,39 4 x 0,75 0,6 0,9 7, ,7 4 x 1 0,6 0,9 7, ,0 4 x 1,5 0,8 1,1 9, ,7 CABLES IN RUBBER 30
31 Number and crosssectional area f conductor Nominal thickness of insulation Nominal thickness of sheath overall diameter net weight nxmm 2 mm mm mm kg/km 4 x 2,5 0,9 1,2 11, ,21 4 x 4 1,0 1,3 13, ,09 4 x 6 1,0 1,5 15, ,39 5 x 0,75 0,6 1,0 8, ,7 5 x 1 0,6 1,0 8, ,0 5 x 1,5 0,8 1,1 10, ,7 5 x 2,5 0,9 1,3 12, ,21 Current ratings Ambient air temperature: 30 C; conductor operating temperature: 60 C Conductor cross-section (mm 2 ) Current ratings in Ampere (A) Single phase 0, , , These values apply to the majority of cases. Further information should be sought in unusual cases eg.: when high ambient temperatures are involved, ie. above 30 o C where long lengths are used where ventilation is restricted where the cords are used for other purposes, eg. internal wiring of apparatus. 1 TYPE: H07RN-F 450/750V NORM: DIN VDE , BS 7919, HD 22.4 Three phase Maximum resistance of conductor at 20 C CONSTRUCTION: Conductor: Insulation: Sheath: Colour of sheath: EPR rubber type EI4 black acc. to HD 308 S2 or BS 7919 Test voltage 50Hz: 2500V Maximum conductor operating temperature: + 60 o C -30 o C Lowest installation temperature: -25 o C Maximum short-circuit conductor temperature: +200 o C Minimum bending radius: 7,5 x D, D overall diameter of cable Flame propagation: EN (IEC ) The product is conformed with the RoHS Direktive 2002/95/CE, Low-Voltage Direktive 73/23/EEC and 93/68/ECC Application: damp and wet areas as well as in open air in agriculture plants, eg. for industrial and agricultural workshop appliances, large boiling installations, heating plates, inspections lamps, electrical tools such as drills, circular saws, domestic electric tools, and also for transportable motors or machines on building sites or in agricultural workings etc. and also for motor connections of hoisting motors and the like. Standard length cable packing: 500 or 1000 m on drums. Other forms of packing and delivery are available on request. CABLES IN RUBBER 31
32 Number and crosssectional area of conductor Maximum diameter of wires Nominal thickness of insulation Single layer Nominal thickness of sheath Two layers overall diameter net weight nxmm 2 mm mm mm mm mm mm kg/km 1 x 1,5 0,26 0,8 1,4 5, x 2,5 0,26 0,9 1,4 6, x 4 0,31 1,0 1,5 7, x 6 0,31 1,0 1,6 8, x 10 0,41 1,2 1,8 10, x 16 0,41 1,2 1,9 11, x 25 0,41 1,4 2,0 13, x 35 0,41 1,4 2,2 14, x 50 0,41 1,6 2,4 17, x 70 0,51 1,6 1,0 1,6 19, x 95 0,51 1,8 1,1 1,7 22, x 120 0,51 1,8 1,2 1,8 23, x 150 0,51 2,0 1,3 1,9 26, x 185 0,51 2,2 1,4 2,0 29, x 240 0,51 2,4 1,4 2,1 31, x 300 0,51 2,6 1,4 2,2 35, x 400 0,51 2,8 1,5 2,3 38, x 500 0,51 3,0 1,6 2,4 43, x 630 0,51 3,0 1,6 2,5 48, x 1 0,21 0,8 1,3 8, x 1,5 0,26 0,8 1,5 9, x 2,5 0,26 0,9 1,7 11, x 4 0,31 1,0 1,8 12, x 6 0,31 1,0 2,0 14, x 10 0,41 1,2 1,2 1,9 19, x 16 0,41 1,2 1,3 2,0 22, x 25 0,41 1,4 1,4 2,2 25, x 35* 0,41 1,4 1,5 2,30 27, x 50* 0,41 1,6 1,7 2,70 33, x 1 0,21 0,8 1,4 8, x 1,5 0,26 0,8 1,6 9, x 2,5 0,26 0,9 1,8 11, x 4 0,31 1,0 1,9 13, x 6 0,31 1,0 2,1 15, x 10 0,41 1,2 1,3 2,0 20, x 16 0,41 1,2 1,4 2,1 23, x 25 0,41 1,4 1,5 2,3 27, x 35 0,41 1,4 1,6 2,5 29, x 50 0,41 1,6 1,8 2,7 35, x 70 0,51 1,6 1,9 2,9 40, x 95 0,51 1,8 2,1 3,2 46, x 120 0,51 1,8 2,2 3,4 49, x 150 0,51 2,0 2,4 3,6 55, x 185 0,51 2,2 2,5 3,9 61, x , x 1 0,21 0,8 1,5 9, x 1,5 0,26 0,8 1,7 10, x 2,5 0,26 0,9 1,9 12, x 4 0,31 1,0 2,0 15, x 6 0,31 1,0 2,3 17, x 10 0,41 1,2 1,4 2,0 22, x 16 0,41 1,2 1,4 2,2 25, x 25 0,41 1,4 1,6 2,5 30, x 35 0,41 1,4 1,7 2,7 33, x 50 0,41 1,6 1,9 2,9 39, x 70 0,51 1,6 2,0 3,2 44, x 95 0,51 1,8 2,3 3,6 52, Inner Outer CABLES IN RUBBER 32
33 Number and crosssectional area of conductor Maximum diameter of wires Nominal thickness of insulation Single layer Nominal thickness of sheath Two layers Inner Outer overall diameter net weight nxmm 2 mm mm mm mm mm mm kg/km 4 x 120 0,51 1,8 2,4 3,6 54, x 150 0,51 2,0 2,6 3,9 61, x 185 0,51 2,2 2,8 4,2 68, x ,1 4,6 74, x 1 0,21 0,8 1,6 10, x 1,5 0,26 0,8 1,8 12, x 2,5 0,26 0,9 2,0 14, x 4 0,31 1,0 2,2 16, x 6 0,31 1,0 2,5 19, x 10 0,41 1,2 1,4 2,2 25, x 16 0,41 1,2 1,5 2,4 28, x 25 0,41 1,4 1,7 2,7 33, x 35* 0,41 1,4 1,8 2,80 36, x 50* 0,41 1,6 2,0 3,20 44, x 70* 0,51 1,6 2,2 3,40 49, x 95* 0,51 1,8 2,6 3,90 58, x 120* 0,51 1,8 2,6 4,20 61, x 150* 0,51 2,0 2,8 4,20 68, x 1* 0,21 0,8 2,4 13, x 1,5 0,26 0,8 2,5 14, x 2,5 0,26 0,9 2,7 17, x 4 0,31 1,0 2,9 20, x 1* 0,21 0,8 2,4 14, x 1,5 0,26 0,8 2,5 15, x 2,5 0,26 0,9 2,7 18, x 4 0,31 1,0 2,9 21, x 6* 0,31 1,0 3,1 23, x 10* 0,41 1,2 3,4 29, x 1,5 0,26 0,8 2,6 17, x 2,5 0,26 0,9 2,8 20, x 4 0,31 1,0 3,1 23, x 1,5 0,26 0,8 2,7 18, x 2,5 0,26 0,9 3,0 21, x 1* 0,21 0,8 2,6 17, x 1,5 0,26 0,8 2,8 18, x 2,5 0,26 0,9 3,0 21, x 4 0,31 1,0 3,3 25, x 1* 0,21 0,8 2,7 17, x 1,5 0,26 0,8 2,9 19, x 2,5 0,26 0,9 3,1 22, x 4 0,31 1,0 3,5 26, x 1* 0,21 0,8 2,8 18, x 1,5 0,26 0,8 2,9 20, x 2,5 0,26 0,9 3,2 23, x 2,5 0,26 0,9 3,3 25, x 1* 0,21 0,8 2,8 19, x 1,5 0,26 0,8 3,0 21, x 2,5 0,26 0, , x 1* 0,21 0, , x 1,5 0,26 0,8 3,2 22, x 2,5 0,26 0,9 3,5 26, x 4 0,31 1,0 3,9 31, x 1,5 0,26 0,8 3,1 23, x 2,5 0,26 0,9 3,4 27, x 1* 0,21 0, , x 1,5 0,26 0,8 3,5 26, x 2,5 0,26 0,9 3,9 30, CABLES IN RUBBER 33
34 Number and crosssectional area of conductor Maximum diameter of wires Nominal thickness of insulation Single layer Nominal thickness of sheath Two layers Inner Outer overall diameter net weight nxmm 2 mm mm mm mm mm mm kg/km 27 x 1,5 0,26 0,8 3,5 26, x 2,5 0,26 0,9 3,9 31, x 1,5 0,26 0,8 3,8 29, x 2,5 0,26 0,9 4,3 35, * Not in standard. CURRENT RATINGS FOR HEAVY DUTY RUBBER INSULATED H07RN-F Conductor cross-section, mm 2 Single phase Current rating, A Three phase , , core cables are bunched (2 cables touching side by side and 3 cables in trefoil). Conductor cross-section (mm 2 ) single core 2-core 3- core 3- core 4-core 5-core 2 cores loaded 3 cores loaded 2 cores loaded 2 cores loaded 3 cores loaded* 3 cores loaded 3 cores loaded CURRENT RATINGS (A) Temperature correction factors Ambient air temperature, C Correction factor 1,00 0,91 0,82 0,71 0,58 0,41 Conversion factors for multicore cable ( > 5 cores) valid for cross-section to 10 mm 2 Number of loaded cores Correction factor 0,75 0,65 0,55 0,50 0,45 0,40 0,35 Current ratings acc to: DIN VDE and HD 516 S2. CABLES IN RUBBER 34
35 TYPE: NSGAFOU 1,8/3 kv NORM: DIN VDE 0250 p. 602 CONSTRUCTION: Separator: Semi-conducting tape under insulation Conductor: Annealed tinned copper conductor class 5 acc. to IEC Insulation: EPR thermosetting compound type 3GI3 to DIN VDE 0207 p. 20 Outer sheath: chloroprene rubber type 5GM3 to DIN VDE 0207 p. 21 Colour of outer sheath: Features: Standard length cable packing: Bending radius: black 500 m on drums. Other forms of packing and delivery are available on request. Temperature range: 0 C, for installation -40 up to 90 0 C. Tests: DIN VDE 0250 Number and cross-sectional area of conductor Nominal thickness of insulation Nominal Thickness of sheath overall diameter net weight of cables mm 2 mm mm mm kg/km 1x ,8 6,0 44 1x ,8 6,2 57 1x ,8 6,7 74 1x ,8 7,3 99 1x ,8 8, x ,8 10, x ,0 12, x ,0 13, x ,0 15, x ,0 16, x ,0 19, x ,0 20, x ,2 23, x ,2 25, x ,2 27, x ,2 31, x400* 3.1 1,4 34, x500* 3.4 1,6 43, * Behind of standard CABLES IN RUBBER 35
36 WELDING CABLES H01N2-D, H01N2-E TYPE: H01N2-D, H01N2-E 100/100 V Neoprene insulated welding cables NORM: HD 22.6, DIN VDE , BS 638, NFC CONSTRUCTION: Conductor: Insulation: Colour of sheath: tinned or plain annealed copper stranded wires black Test voltage 50Hz: 1000V Maximum conductor operating temperature: + 85 o C -40 o C Lowest installation temperature: -20 o C Maximum short-circuit conductor temperature: +250 o C Pulling strength: the maximum static pulling strength may not exceed 15 N/mm 2 Minimum bending radius: 8 < D < D 20 D > 20 Free movement 4 D 5 D 6 D Under mechanical load 6 D 6 D 8 D Flame propagation: EN (IEC ) The product is conformed with the RoHS Direktive 2002/95/CE, Low-Voltage Direktive 73/23/EEC and 93/68/ECC Application: propagation, suitable for use in dry and damp conditions, outdoors and indoors. Nominal crosssectional area of wires weight at temperature 20 0 C Maximum diameter Maximum conductor resistance Nominal thickness of insulation overall diameter of conductor in conductor tinned plain mm 2 mm mm mm kg/km HO1N2-D 10 0,21 2,0 8, ,95 1, ,21 2,0 9, ,24 1, ,21 2,0 10, ,795 0, ,21 2,0 11, ,565 0, ,21 2,2 13, ,393 0, ,21 2,4 15, ,277 0, ,21 2,6 17, ,210 0, ,51 2,8 19, ,164 0, ,51 3,0 21, ,132 0, ,51 3,2 24, ,108 0,106 HO1N2-E 10 0,16 1,2 6, ,95 1, ,16 1,2 7, ,24 1, ,16 1,2 8, ,795 0, ,16 1,2 10, ,565 0, ,16 1,5 12, ,393 0, ,16 1,5 14, ,277 0, ,16 1,8 16, ,210 0, ,21 1,8 18, ,164 0, ,21 1,8 20, ,132 0, ,21 1,8 21, ,108 0,106 CABLES IN RUBBER 36
37 Current raings and voltage drop for Arc Welding Cables HD 516 S2 Nominal cross-sectional area, copper conductor 100 % 85 % 60 % 35 % (mm 2 ) A A A A Nominal cross-sectional area, copper conductor 100% 85% 80% 60% 35% 20% 8% (mm 2 ) A A A A A A A Current rating for repear cycle operation based on a 10 minute repeat period Nominal cross-sectional area, copper conductor 100% 85% 80% 60% 35% 20% 8% (mm 2 ) A A A A A A A For cables in free air at an ambient temperature of 25 C and conductor temperature of 85 C Voltage drop at normal and elevated temperatures Nominal cross-sectional area, copper conductor d.c. voltage drop per 100A per 10 m of cable at 20 C 60 C 85 C (mm 2 ) V V V 10 1,95 2,26 2, ,24 1,430 1, ,795 0,920 0, ,565 0,654 0, ,393 0,455 0, ,277 0,321 0, ,210 0,243 0, ,164 0,190 0, ,132 0,153 0, ,108 0,125 0,136 CABLES IN RUBBER 37
38 38
39 CHAPTER V HEAT RESISTING SILICONE CABLES 39
40 RUBBER, HEAT RESISTING SINGLE CORE NON-SHEATHED CABLES SIF TYPE: SIF 300/500 V Single core silicone rubber insulated cable, halogen-free NORM: Adapted to DIN VDE 0250, HD 22 CONSTRUCTION: Conductor: Insulation: special silicone compound type EI2 natural, green/yellow, blue, black, brown or others colours Maximum conductor operating temperature: +180 o C -60 o C -25 o C Maximum short-circuit conductor temperature: +350 o C Test voltage 50Hz: 2000V Minimum bending radius: 4 x cable diameter Flame retardant: EN The product is conformed with the RoHS Direktive 2002/95/CE, Low-Voltage Direktive 73/23/EEC and 93/68/ECC Features: o C) - preservation of mechanical characteristics within a wide range of temperatures (-60 o C to +180 o C) - high auto ignition temperature fumes sunlight and weather resistant ammonium, diluted acids and alkalis, sea water Application: Silicone rubber insulated cables are intended for use wherever insulation is subjected to mechanical properties remain unaltered with time both at high and low temperatures, heat-resistant up to 180 o C. Specially recommended for: household appliances, cooking surfaces, heating apparatus, industrial converters, radiators, ovens and ventilators, electric motors, lighting (halogen lamps etc.), high voltage electrical cabins and circuits, civil and industrial plant, the automobile industry, metallurgical facilities, steel mills, hot rolling mills and casting houses. Standard length cable packing: 500 and 1000 m on spools. Other forms of packing and delivery are available on request. HEAT RESISTING SILICONE CABLES 40
41 Conductor Maximum resistance cross-section overall diameter net weight of conductor at 20 C Current ratings* mm 2 mm kg/km /km A 0,5 2,1 8 40,1 10 0,75 2, , , ,0 19 1,5 2, ,7 24 2,5 3,4 28 8, ,1 43 5, ,6 61 3, , , , , , , , , , , , , , , , , Single core cables laid in open air with a spacing at least equal to cable diameter. Power ratings for ambient temperature over 150 o C. The following conversion factors are valid: Ambient temperature C Correction factors 1,0 0,91 0,82 0,71 0,58 0,41 HEAT RESISTING SILICONE CABLES 41
42 RUBBER, HEAT RESISTING SHEATHED CABLES SIHF TYPE: SIHF 300/500 V NORM: Adapted to DIN VDE CONSTRUCTION: Conductor: Insulation: special silicone compound type EI2 DIN VDE twin core blue, brown 3-core green-yellow, blue, brown, 4-core green-yellow, brown, black, grey 5 - core green-yellow, blue, brown, black, grey Outer sheath: special silicone compound type EI2 Colour of sheath: Redbrown, white or black Maximum conductor operating temperature: +180 o C -60 o C -25 o C Maximum short-circuit conductor temperature: +350 o C Test voltage 50Hz: 2000V Minimum bending radius: 7,5 x cable diameter Maximum permissible load: 15 N/mm 2 of the total copper cross-sectional area Flame retardant: EN The product is conformed with the RoHS Direktive 2002/95/CE, Low-Voltage Direktive 73/23/EEC and 93/68/ECC Features: o C) - preservation of mechanical characteristics within a wide range of temperatures (-60 o C to +180 o C) - high auto ignition temperature fumes sunlight and weather resistant ammonium, diluted acids and alkalis, sea water Application: Silicone rubber insulated cables are intended for use wherever insulation is subjected to mechanical properties remain unaltered with time both at high and low temperatures, heat-resistant up to 180 o C. Specially recommended for: household appliances, cooking surfaces, heating apparatus, industrial converters, radiators, ovens and ventilators, electric motors, lighting (halogen lamps etc.), high voltage electrical cabins and circuits, civil and industrial plant, the automobile industry, metallurgical facilities, steel mills, hot rolling mills and casting houses. Standard length cable packing: 100 m in rings or 500 m on spools. Other forms of packing and delivery are available on request. HEAT RESISTING SILICONE CABLES 42
43 Number and crosssectional area of conductor Nominal thickness of insulation Nominal thickness of sheath overall diameter net weight Maximum resistance of conductor at 20 C nxmm 2 mm mm mm kg/km 2 x 0,5 0,6 0,8 5, ,1 2 x 0,75 0,6 0,8 6, ,7 2x1 0,6 0,9 6, ,0 2 x 1,5 0,6 1,0 7, ,7 2 x 2,5 0,7 1,1 9, ,21 2x4 1,0 1,2 11, ,09 2x6 1,0 1,3 12, ,39 2x10 1,2 2,0 16, ,95 2x16 1,2 2,2 19, ,24 3 x 0,5 0,6 0,8 6, ,1 3 x 0,75 0,6 0,9 6, ,7 3x1 0,6 0,9 6, ,0 3 x 1,5 0,6 1,0 7, ,7 3 x 2,5 0,7 1,1 9, ,21 3x4 1,0 1,2 12, ,09 3x6 1,0 1,4 13, ,39 3x10 1,2 2,2 18, ,95 3x16 1,2 2,3 21, ,24 4 x 0,5 0,6 0,9 6, ,1 4 x 0,75 0,6 0,9 7, ,7 4x1 0,6 1,0 7, ,0 4 x 1,5 0,6 1,1 8, ,7 4 x 2,5 0,7 1,2 10, ,21 4x4 1,0 1,3 13, ,09 4x6 1,0 1,5 15, ,39 4x10 1,2 2,2 20, ,95 4x16 1,2 2,3 23, ,24 4x25 1,4 2,7 27, ,795 4x35 1,4 2,9 29, ,565 5 x 0,5 6, ,1 5 x 0,75 0,6 1,0 8, ,7 5x1 0,6 1,1 8, ,0 5 x 1,5 0,6 1,2 9, ,7 5 x 2,5 0,7 1,3 11, ,21 5x4 1,0 1,4 14, ,09 5x6 1,0 1,6 16, ,39 Current ratings for multicore silicone cables Nominal crosssectional Current ratings* Nominal crosssectional Current ratings* area of conductor current-carrying capacity protective fuse area of conductor current-carrying capacity protective fuse mm 2 A A mm 2 A A 0, , , , Multi core cables laid in open air. Power ratings for ambient temperature over 150 o C. The following conversion factors are valid: Ambient temperature C Correction factors 1,0 0,91 0,82 0,71 0,58 0,41 HEAT RESISTING SILICONE CABLES 43
44 44
45 CHAPTER VI POWER AND CONTROL CABLES 45
46 LV PVC INSULATED POWER AND CONTROL CABLES NYY, MMO TYPE: NYY 0,6/1 kv PVC insulated and PVC sheathed power and control cable NORM: DIN VDE , DIN VDE CONSTRUCTION: Conductor: annealed copper solid class 1(RE), circular or circular compacted stranded conductor class 2 (RM) or stranded sector shaped conductor class 2 (SM) acc. to DIN EN Insulation: special PVC compound type DIV4 acc. to HD Inner covering: compound Sheath: special PVC compound type DMV5 acc. to HD Colour of sheath: black DIN VDE , HD 308 S2 Number of core: with protective conductor-j without protective conductor-0 single-core green/yellow black twin - blue, brown 3-core green/yellow, blue, brown brown, black, grey 4-core green/yellow, brown, black, grey blue, brown, black, grey 5-core green/yellow, blue, brown, black, grey blue, brown, black, grey, black 7-core and more green/yellow, other cores black with white numbering black with white numbering Maximum conductor operating temperature: +70 o C -30 o C Lowest installation temperature: -5 o C Maximum short-circuit conductor temperature: o C for cross-sectional area of conductor 300 mm 2 and o C for cross-sectional area of conductor > 300 mm 2 Minimum bending radius: 15 x D single core cables, 12 x D multicore cables, D overall diameter Max. permissible tensile stress with cable grip for Cu-conductor: 50 N/mm 2 Flame retardant: DIN EN The product is conformed with the RoHS Direktive 2002/95/CE, Low-Voltage Direktive 73/23/EEC and 93/68/ECC Application: Standard length cable packing: PVC insulated and sheathed power and auxiliary ontrol cables for the supply of electrical energy. Special for installations in the open air, in underground and water, indoors, in cable ducts. 500 or 100 m on drums. Other forms of packing and delivery are available on request. Number and crosssectional area of conductor Nominal thickness of insulation Nominal thickness of sheath overall diameter net weight of cables Maximum conductor resistance at 20 o C nxmm 2 mm mm mm kg/km 1 x 1,5RE 0,8 1,8 6, ,1 1 x 1,5RM 0,8 1,8 6, ,1 1 x 2,5RE 0,8 1,8 6,9 74 7,41 1 x 4RE 1,0 1,8 7, ,61 1 x 6RE 1,0 1,8 8, ,08 1 x 10RE 1,0 1,8 10, ,83 1 x 10RMC 1,0 1,8 9, ,83 POWER AND CONTROL CABLES 46
47 Number and crosssectional area of conductor Nominal thickness of insulation Nominal thickness of sheath overall diameter net weight of cables Maximum conductor resistance at 20 o C nxmm 2 mm mm mm kg/km 1 x 16RE 1,0 1,8 11, ,15 1 x 16RMC 1,0 1,8 10, ,15 1 x 25RMC 1,2 1,8 12, ,727 1 x 35RMC 1,2 1,8 13, ,524 1 x 50RMC 1,4 1,8 15, ,387 1 x 70RMC 1,4 1,8 16, ,268 1 x 95RMC 1,6 1,8 18, ,193 1 x 120RMC 1,6 1,8 20, ,153 1 x 150RMC 1,8 1,8 22, ,124 1 x 185RMC 2,0 1,8 24, , x 240RMC 2,2 1,8 27, , x 300RMC 2,4 1,9 29, , x 400RM 2,6 2,0 34, , x 500RM 2,8 2,1 38, , x 1,5RE 0,8 1,8 11, ,1 2 x 2,5RE 0,8 1,8 11, ,41 2 x 2,5RM 0,8 1,8 12, ,41 2 x 4RE 1,0 1,8 13, ,61 2 x 4RM 1,0 1,8 14, ,61 2 x 6RE 1,0 1,8 14, ,08 2 x 6RM 1,0 1,8 15, ,08 2 x 10RE 1,0 1,8 16, ,83 2 x 10RMC 1,0 1,8 16, ,83 2 x 16RE 1,0 1,8 18, ,15 2 x 16RMC 1,0 1,8 18, ,15 2 x 25RM 1,2 1,8 22, ,727 2 x 50RM 1,4 1,8 27, ,387 3 x 1,5RE 0,8 1,8 11, ,1 3 x 1,5RM 0,8 1,8 12, ,1 3 x 2,5RE 0,8 1,8 12, ,41 3 x 2,5RM 0,8 1,8 12, ,41 3 x 4RE 1,0 1,8 14, ,61 3 x 6RE 1,0 1,8 15, ,08 3 x 6RM 1,0 1,8 16, ,08 3 x 10RE 1,0 1,8 17, ,83 3 x 10RM 1,0 1,8 17, ,83 3 x 16RE 1,0 1,8 19, ,15 3 x 25RM 1,2 1,8 23, ,727 3 x 35SM 1,2 1,8 23, ,524 3 x 50SM 1,4 1,8 26, ,387 3 x 70SM 1,4 2,0 30, ,268 3 x 95SM 1,6 2,1 34, ,193 3 x 120SM 1,6 2,2 36, ,153 3 x 150SM 1,8 2,3 41, ,124 3 x 185SM 2,0 2,5 45, , x 240SM 2,2 2,7 50, , x 1,5RE 0,8 1,8 12, ,1 4 x 1,5RM 0,8 1,8 12, ,1 4 x 2,5RE 0,8 1,8 13, ,41 4 x 2,5RM 0,8 1,8 13, ,41 4 x 4RE 1,0 1,8 15, ,61 4 x 4RM 1,0 1,8 16, ,61 4 x 6RE 1,0 1,8 16, ,08 4 x 6RM 1,0 1,8 17, ,08 4 x 10RE 1,0 1,8 18, ,83 4 x 10RM 1,0 1,8 19, ,83 4 x 16RE 1,0 1,8 20, ,15 POWER AND CONTROL CABLES 47
48 Number and crossectional area of conductor Nominal thickness of insulation Nominal thickness of sheath overall diameter net weight of cables Maximum conductor resistance at 20 o C nxmm 2 mm mm mm kg/km 4 x 16RM 1,0 1,8 21, ,15 4 x 25RM 1,2 1,8 25, ,727 4 x 35RM 1,2 1,8 28, ,524 4 x 35SM 1,2 1,8 26, ,524 4 x 50SM 1,4 1,9 30, ,387 4 x 70SM 1,4 2,1 34, ,268 4 x 95SM 1,6 2,2 38, ,193 4 x 120SM 1,6 2,3 42, ,153 4 x 150SM 1,8 2,5 46, ,124 4 x 185SM 2,0 2,7 51, , x 240SM 2,2 2,9 57, , x 16RE/10RE 1,0 / 1,0 1,8 20, ,15 / 1,83 3 x 25RM/16RE 1,2 / 1,0 1,8 24, ,727 / 1,15 3 x 35RM/16RE 1,2 / 1,0 1,8 26, ,524 / 1,15 3 x 50SM/25RM 1,4 / 1,2 1,9 30, ,387 / 0,727 3 x 70SM/35SM 1,4 / 1,2 2,0 32, ,268 / 0,524 3 x 95SM/50SM 1,6 / 1,4 2,2 37, ,193 / 0,387 3 x 120SM/70SM 1,6 / 1,4 2,3 40, ,153 / 0,268 3 x 150SM/70SM 1,8 / 1,4 2,4 44, ,124 / 0,268 3 x 185SM/95SM 2,0 / 1,6 2,6 49, ,0991 / 0,193 3 x 240SM/120SM 2,2 / 1,6 2,8 56, ,0754 / 0,153 5 x 1,5RE 0,8 1,8 13, ,1 5 x 1,5RM 0,8 1,8 13, ,1 5 x 2,5RE 0,8 1,8 14, ,41 5 x 2,5RM 0,8 1,8 14, ,41 5 x 4RE 1,0 1,8 16, ,61 5 x 4RM 1,0 1,8 17, ,61 5 x 6RE 1,0 1,8 17, ,08 5 x 10RE 1,0 1,8 20, ,83 5 x 10RMC 1,0 1,8 20, ,83 5 x 16RE 1,0 1,8 22, ,15 5 x 16RMC 1,0 1,8 23, ,15 5 x 25RMC 1,2 1,8 28, ,727 5 x 35RMC 1,2 1,9 31, ,524 5 x 50RMC 1,4 2,0 36, ,387 5 x 70RMC 1,4 2,2 40, ,268 5 x 95RMC 1,6 2,4 47, ,193 6 x 1,5RE 0,8 1,8 14, ,1 6 x 2,5RE 0,8 1,8 15, ,41 6 x 2,5RM 0,8 1,8 16, ,41 7 x 1,5RE 0,8 1,8 14, ,1 7 x 1,5RM 0,8 1,8 14, ,1 7 x 2,5RE 0,8 1,8 15, ,41 7 x 2,5RM 0,8 1,8 16, ,41 7 x 4RE 1,0 1,8 17, ,61 7 x 6RE 1,0 1,8 19, ,08 7 x 10RE 1,0 1,8 21, ,83 8 x 1,5RE 0,8 1,8 15, ,1 8 x 1,5RM 0,8 1,8 15, ,1 8 x 2,5RE 0,8 1,8 16, ,41 8 x 2,5RM 0,8 1,8 17, ,41 9 x 1,5RE 0,8 1,8 16, ,1 9 x 2,5RE 0,8 1,8 17, ,41 10 x 1,5RE 0,8 1,8 17, ,1 10 x 2,5RE 0,8 1,8 18, ,41 10 x 2,5RM 0,8 1,8 19, ,41 10 x 4RE 1,0 1,8 22, ,61 POWER AND CONTROL CABLES 48
49 Number and crossectional area of conductor Nominal thickness of insulation Nominal thickness of sheath overall diameter net weight of cables Maximum conductor resistance at 20 o C nxmm 2 mm mm mm kg/km 12 x 1,5RE 0,8 1,8 17, ,1 12 x 1,5RM 0,8 1,8 18, ,1 12 x 2,5RE 0,8 1,8 19, ,41 12 x 2,5RM 0,8 1,8 20, ,41 12 x 6RE 1,0 1,8 24, ,08 14 x 1,5RE 0,8 1,8 18, ,1 14 x 2,5RE 0,8 1,8 19, ,41 14 x 4RE 1,0 1,8 23, ,61 16 x 1,5RE 0,8 1,8 19, ,1 16 x 2,5RE 0,8 1,8 20, ,41 19 x 1,5RE 0,8 1,8 20, ,1 19 x 1,5RM 0,8 1,8 21, ,1 19 x 2,5RE 0,8 1,8 21, ,41 19 x 2,5RM 0,8 1,8 23, ,41 19 x 4RE 1,0 1,8 26, ,61 20 x 2,5RE 0,8 1,8 22, ,41 21 x 1,5RE 0,8 1,8 20, ,1 21 x 2,5RE 0,8 1,8 22, ,41 24 x 1,5RE 0,8 1,8 23, ,1 24 x 1,5RM 0,8 1,8 24, ,1 24 x 2,5RE 0,8 1,8 25, ,41 24 x 2,5RM 0,8 1,8 26, ,41 25 x 1,5RE 0,8 1,8 23, ,1 27 x 1,5RE 0,8 1,8 23, ,1 27 x 2,5RE 0,8 1,8 25, ,41 30 x 1,5RE 0,8 1,8 24, ,1 30 x 1,5RM 0,8 1,8 25, ,1 30 x 2,5RE 0,8 1,8 26, ,41 31 x 1,5RE 0,8 1,8 25, ,1 31 x 2,5RE 0,8 1,8 27, ,41 33 x 1,5RE 0,8 1,8 25, ,1 37 x 1,5RE 0,8 1,8 25, ,1 40 x 1,5RE 0,8 1,8 26, ,1 40 x 2,5RE 0,8 1,9 29, ,41 40 x 2,5RM 0,8 1,9 31, ,41 52 x 1,5RE 0,8 1,9 30, ,1 52 x 2,5RE 0,8 2,0 34, ,41 61 x 1,5RE 0,8 2,0 32, ,1 61 x 2,5RE 0,8 2,1 36, ,41 Current ratings* Operating temperature at conductor 70 o o C, ground temperature 20 o C POWER AND CONTROL CABLES 49
50 Installation Number of loaded cores laying in ground laying in air Cross-section, mm 2 Current ratings in Ampere (A) 1, ,5 21 2, ) Rated current for direct current systems with a far-distanced return conductor. The values are referred to the following basic conditions: Laying in ground Laying in air Ground temperature at installation depth: 20 o C Ambient temperature: 30 o C Load factor: 0,7 Load factor: 1,0 Soil-thermal resistivity of moist area: 1,0 k m/w Arrangement: free in air, protection against direct solar radiation, no Soil-thermal resistivity of dry area: 2,5 k m/w external heat sources, unrestricted dissipation Laying depth: 0,7 m of heat. Correction factors for various ambient air temperatures Ambient temperature, C) Rating factor 1,22 1,17 1,12 1,06 1,00 0,94 0,87 0,79 0,71 Current ratings for control cables HD 627 S1 3 3 Number of loaded cores laying in ground laying in air Cross-section, mm 2 Current ratings in Ampere (A) 1, ,5 2, The conversion factors are to be used for laying the cables in ground or in air, to the values given in above tables Number of loaded cores Laying in ground Laying in air 5 0,70 0,75 7 0,60 0, ,50 0, ,45 0, ,40 0, ,35 0, ,30 0, ,25 0,30 Note: valid for cross-section 1,5 to 10 mm 2. POWER AND CONTROL CABLES 50
51 TYPE: MMO 450/750 V PVC insulated and PVCsheathed control cable NORM: SFS 3714, HD 627-4D CONSTRUCTION: Conductor: plain annealed copper circular solid class 1 acc. to EN Insulation: black lead free PVC compound type TI1 Separator: Sheath: numbering ( if required one yellow/green core) polyester tape white lead free PVC compound type TM1 Maximum continuous conductor operating temperature: +70 o C -30 o C -15 o C Maximum short-circuit conductor temperature: o C Flame propagation: EN Minimum bending radius: 12 x D multicore cables, D overall diameter The product is conformed with the RoHS Direktive 2002/95/CE, Low-Voltage Direktive 73/23/EEC and 93/68/ECC Application: and signalling circuits. Special for installations indoor and outdoors. Not to be laid in soil. Standard length cable packing: 500 m on drums. Other forms of packing and delivery are available on request. Number and crosssectional area of conductor Nominal thickness of insulation Minimum thickness of sheath overall diameter net weight of cables nxmm 2 mm mm mm kg/km 7 x 1,5 0,7 1,6 11, x 1,5 0,7 1,6 14, x 1,5 0,7 1,6 17, x 1,5 0,7 1,7 20, x 1,5 0,7 1,8 23, x 2,5 0,8 1,6 13, x 2,5 0,8 1,6 17, x 2,5 0,8 1,7 20, x 2,5 0,8 1,8 24, x 2,5 0,8 2,0 27, POWER AND CONTROL CABLES 51
52 LV XLPE INSULATED POWER AND CONTROL CABLES N2XY, AXMK TYPE: N2XY 0,6/1 kv XLPE insulated and PVC sheathed power and control cable NORM: DIN VDE , DIN VDE , IEC CONSTRUCTION: Conductor: annealed copper solid class 1(RE), circular or circular compacted stranded conductor class 2 (RM) or stranded sector shaped conductor class 2 (SM) acc. to HD 383 Insulation: special XLPE compound type DXI3 acc. to HD Inner covering: compound Sheath: special PVC compound type DMV6 acc. to HD Colour of sheath: black UV resistant DIN VDE Number of core: with protective conductor-j without protective conductor-0 single-core green/yellow black twin green-yellow, black 1) blue, brown 3-core green/yellow, blue, brown brown, black, grey 4-core green/yellow, brown, black, grey blue, brown, black, grey 5-core green/yellow, blue, brown, black, grey blue, brown, black, grey, black 7-core and more green/yellow, other cores black with white numbering black with white numbering 1) Only for cable with cross-sectional area of conductor > 10 mm 2 Maximum conductor operating temperature: +90 o C -30 o C Lowest installation temperature: -5 o C Maximum short-circuit conductor temperature: o C Minimum bending radius: 15 x D single core cables, 12 x D multicore cables, D overall diameter Max. permissible tensile stress with cable grip for Cu-conductor: 50 N/mm 2 Flame retardant: DIN EN Flame retardant: test method B according to DIN VDE 0472 part 804 and IEC Application: XLPE insulated and PVC sheathed power and auxiliary control cables for the supply of electrical energy. Special for installations in the open air, in underground and water, indoors, in cable ducts. Standard length cable packing: 1000 or 500 m on drums. Other forms of packing and delivery are available on request. Number and crosssectional area of conductor Minimum number of wires in conductor Nominal thickness of insulation Nominal thickness of sheath overall diameter net weight of cables Maximum conductor resistance at temperature 20 o C nxmm 2 n mm mm mm kg/km /km 1 x 1,5 RE 1 0,7 1,8 6, ,1 1 x 1,5 RM 7 0,7 1,8 6, ,1 1 x 2,5 RE 1 0,7 1,8 6,7 68 7,41 1 X 2,5 RM 7 0,7 1,8 7,0 72 7,41 1 x 4 RE 1 0,7 1,8 7,2 86 4,61 1 x 4 RM 7 0,7 1,8 7,5 90 4,61 1 x 6 RE 1 0,7 1,8 7, ,08 POWER AND CONTROL CABLES 52
53 Number and crosssectional area of conductor Minimum number of wires in conductor Nominal thickness of insulation Nominal thickness of sheath overall diameter net weight of cables Maximum conductor resistance at temperature 20 o C nxmm 2 n mm mm mm kg/km /km 1x6RM 7 0,7 1,8 8, ,08 1 x 10 RE 1 0,7 1,8 8, ,83 1 x 10 RM 7 0,7 1,8 9, ,83 1 x 16 RE 1 0,7 1,8 9, ,15 1 x 16 RM 7 0,7 1,8 9, ,15 1 x 25 RM 7 0,9 1,8 11, ,727 1 x 35 RM 7 0,9 1,8 12, ,524 1 x 50 RM 19 1,0 1,8 14, ,387 1 x 70 RM 19 1,1 1,8 15, ,268 1 x 95 RM 19 1,1 1,8 17, ,193 1 x 120 RM 37 1,2 1,8 19, ,153 1 x 150 RM 37 1,4 1,8 21, ,124 1 x 185 RM 37 1,6 1,8 23, , x 240 RM 61 1,7 1,8 25, , x 300 RM 61 1,8 1,8 27, , x 300 RM 61 1,8 1,8 29, , x 400 RM 61 2,0 1,9 33, , x 500 RM 61 2,2 2,0 36, , x 1,5 RE 1 0,7 1,8 10, ,1 2 x 1,5 RM 7 0,7 1,8 10, ,1 2 x 2,5 RE 1 0,7 1,8 10, ,41 2 x 2,5 RM 7 0,7 1,8 11, ,41 2 x 4 RE 1 0,7 1,8 11, ,61 2 x 4 RM 7 0,7 1,8 12, ,61 2 x 6 RE 1 0,7 1, ,08 2 x 6 RM 7 0,7 1,8 13, ,08 2 x 10 RE 1 0,7 1,8 14, ,83 2 x 10 RM 7 0,7 1,8 15, ,83 2 x 16 RE 1 0,7 1,8 16, ,15 2x16RM 7 0,7 1,8 17, ,15 2x25RM 7 0,9 1,8 20, ,727 2 x 35 RM 7 0,9 1,8 22, ,524 2 x 50 RM 19 1,0 1,8 25, ,387 2 x 70 RM 19 1,1 1,8 28, ,268 2 x 95 RM 19 1,1 2,0 33, ,193 2 x 120 RM 37 1,2 2,1 36, ,153 2 x 150 RM 37 1,4 2,2 40, ,124 2 x 185 RM 37 1,6 2,3 45, , x 240 RM 61 1,7 2,5 50, , x 1,5RE 1 0,7 1,8 10, ,1 3 x 1,5RM 7 0,7 1,8 11, ,1 3 x 2,5RE 1 0,7 1,8 11, ,41 3 x 2,5RM 7 0,7 1,8 11, ,41 3 x 4RE 1 0,7 1,8 12, ,61 3 x 4RM 7 0,7 1,8 13, ,61 3 x 6RE 1 0,7 1,8 13, ,08 3 x 6RM 7 0,7 1,8 14, ,08 3 x 10RE 1 0,7 1,8 15, ,83 3 x 10RM 7 0,7 1,8 16, ,83 3 x 16RE 1 0,7 1,8 17, ,15 3 x 16RM 7 0,7 1,8 18, ,15 3 x 25RM 7 0,9 1,8 21, ,727 3 x 35RM 7 0,9 1,8 23, ,524 4 x 1,5RE 1 0,7 1,8 11, ,1 4 x 1,5RM 7 0,7 1,8 11, ,1 4 x 2,5RE 1 0,7 1,8 12, ,41 4 x 2,5RM 7 0,7 1,8 12, ,41 POWER AND CONTROL CABLES 53
54 Number and crosssectional area of conductor Minimum number of wires in conductor Nominal thickness of insulation Nominal thickness of sheath overall diameter net weight of cables Maximum conductor resistance at temperature 20 o C nxmm 2 n mm mm mm kg/km /km 4 x 4RE 1 0,7 1,8 13, ,61 4 x 4RM 7 0,7 1,8 14, ,61 4 x 6RE 1 0,7 1,8 14, ,08 4 x 6RM 7 0,7 1,8 15, ,08 4 x 10RE 1 0,7 1,8 16, ,83 4 x 10RM 7 0,7 1,8 17, ,83 4 x 16RE 1 0,7 1,8 18, ,15 4 x 16RM 7 0,7 1,8 19, ,15 4 x 25RM 7 0,9 1,8 23, ,727 4 x 35RM 7 0,9 1,8 26, ,524 5 x 1,5RE 1 0,7 1,8 12, ,1 5 x 1,5RM 7 0,7 1,8 12, ,1 5 x 2,5RE 1 0,7 1,8 13, ,41 5 x 2,5RM 7 0,7 1,8 13, ,41 5 x 4RE 1 0,7 1,8 14, ,61 5 x 6RE 1 0,7 1,8 15, ,08 5 x 10RE 1 0,7 1,8 17, ,83 5 x 10RMC 7 0,7 1,8 18, ,83 5 x 16RE 1 0,7 1,8 20, ,15 5 x 16RMC 7 0,7 1,8 21, ,15 5 x 25RMC 7 0,9 1,8 25, ,727 5 x 35RMC 7 0,9 1,8 28, ,524 5 x 50RMC 19 1,0 2,0 33, ,387 5 x 70RMC 19 1,1 2,1 37, ,268 5 x 95RMC 19 1,1 2,3 43, ,193 5 x 120RMC 37 1,2 2,4 48, ,153 5 x 150RMC 37 1,4 2,6 54, ,124 5 x 185RMC 37 1,6 2,8 59, , x 1,5RE 1 0,7 1,8 12, ,1 7 x 1,5RE 1 0,7 1,8 12, ,1 7 x 1,5RM 7 0,7 1,8 13, ,1 7 x 2,5RE 1 0,7 1,8 14, ,41 7 x 2,5RM 7 0,7 1,8 14, ,41 7 x 4RE 1 0,7 1,8 15, ,61 9 x 1,5RE 1 0,7 1,8 14, ,1 10 x 1,5RE 1 0,7 1,8 15, ,1 10 x 1,5RM 7 0,7 1,8 16, ,1 10 x 2,5RE 1 0,7 1,8 17, ,41 10 x 2,5RM 7 0,7 1,8 18, ,41 10 x 4RE 1 0,7 1,8 19, ,61 12 x 1,5RE 1 0,7 1,8 16, ,1 12 x 1,5RM 7 0,7 1,8 16, ,1 12 x 2,5RE 1 0,7 1,8 17, ,41 12 x 2,5RM 7 0,7 1,8 18, ,41 12 x 4RE 1 0,7 1,8 19, ,61 14 x 1,5RE 1 0,7 1,8 16, ,1 14 x 1,5RM 7 0,7 1,8 17, ,1 14 x 2,5RE 1 0,7 1,8 18, ,41 14 x 2,5RM 7 0,7 1,8 19, ,41 14 x 4RE 1 0,7 1,8 20, ,61 15 x 2,5RE 1 0,7 1,8 19, ,41 16 x 1,5RE 1 0,7 1,8 17, ,1 16 x 1,5RM 7 0,7 1,8 18, ,1 17 x 4RE 1 0,7 1,8 22, ,61 19 x 1,5RE 1 0,7 1,8 18, ,1 19 x 1,5RM 7 0,7 1,8 19, ,1 19 x 2,5RE 1 0,7 1,8 20, ,41 POWER AND CONTROL CABLES 54
55 Number and crosssectional area of conductor Minimum number of wires in conductor Nominal thickness of insulation Nominal thickness of sheath overall diameter net weight of cables Maximum conductor resistance at temperature 20 o C nxmm 2 n mm mm mm kg/km 19 x 2,5RM 7 0,7 1,8 21, ,41 19 x 4RE 1 0,7 1,8 22, ,61 20 x 2,5RE 1 0,7 1,8 21, ,41 24 x 1,5RE 1 0,7 1,8 21, ,1 24 x 1,5RM 7 0,7 1,8 22, ,1 24 x 2,5RE 1 0,7 1,8 23, ,41 24 x 2,5RM 7 0,7 1,8 24, ,41 30 x 1,5RE 1 0,7 1,8 22, ,1 30 x 1,5RM 7 0,7 1,8 23, ,1 30 x 2,5RE 1 0,7 1,8 24, ,41 30 x 2,5RM 7 0,7 1,8 26, ,41 37 x 1,5RE 1 0,7 1,8 23, ,1 40 x 1,5RE 1 0,7 1,8 24, ,1 40 x 2,5RE 1 0,7 1,8 27, ,41 48 x 1,5RE 1 0,7 1,8 27, ,1 52 x 1,5RE 1 0,7 1,9 28, ,1 62 x 1,5RE 1 0,7 1,9 30, ,1 3 x 35SM 19 0,9 1,8 22, ,524 3 x 50SM 19 1,0 1,8 25, ,387 3 x 70SM 19 1,1 1,9 29, ,268 3 x 95SM 19 1,1 2,0 32, ,193 3 x 120SM 19 1,2 2,2 36, ,153 3 x 150SM 19 1,4 2,3 40, ,124 3 x 185SM 37 1,6 2,4 44, , x 240SM 37 1,7 2,6 50, , x 25RM/16RE 7 / 1 0,9 / 0,7 1,8 22, ,727 / 1,15 3 x 35RM/16RE 7 / 1 0,9 / 0,7 1,8 24, ,524 / 1,15 3 x 50SM/25RM 19 / 7 1,0 / 0,9 1,8 28, ,387 / 0,727 3 x 70SM/35SM 19 / 7 1,1 / 0.9 2,0 31, ,268 / 0,524 3 x 95SM/50SM 19 / 7 1,1 / 1,0 2,1 35, ,193 / 0,387 3 x 120SM/70SM 19 / 19 1,2 / 1,1 2,2 39, ,153 / 0,268 3 x 150SM/70SM 19 / 19 1,4 / 1,1 2,3 43, ,124 / 0,268 3 x 185SM/95SM 37 / 19 1,6 / 1,1 2,5 48, ,0991 / 0,193 3 x 240SM/120SM 37 / 19 1,7 / 1,2 2,7 54, ,0754 / 0,153 4 x 35SM 19 0,9 1,8 26, ,524 4 x 50SM 19 1,0 1,9 29, ,387 4 x 70SM 19 1,1 2,0 34, ,268 4 x 95SM 19 1,1 2,2 38, ,193 4 x 120SM 19 1,2 2,3 42, ,153 4 x 150SM 19 1,4 2,5 47, ,124 4 x 185SM 37 1,6 2,6 52, , x 240Sm 37 1,7 2,8 58, , x 25RM/16RE 7 / 1 0,9 / 0,7 1,8 24, ,727 / 1,15 4 x 35RM/16RE 7 / 1 0,9 / 0,7 1,8 27, ,524 / 1,15 4 x 50RM/25RM 19 / 7 1,0 / 0,9 1,8 31, ,387 / 0,727 4 x 70RM/35RM 19 / 7 1,1 / 0,9 1,9 35, ,268 / 0,524 4 x 95RM/50RM 19 / 19 1,1 / 1,0 2,1 41, ,193 / 0,387 4 x 120RM/70RM 37 / 19 1, ,2 45, ,153 / 0,268 Current ratings* POWER AND CONTROL CABLES 55
56 Operating temperature at conductor 90 o o C, ground temperature 20 o C Installation Number of loaded cores laying in ground laying in air Cross-section, mm 2 Current ratings in Ampere (A) 1, , ) Rated current for direct current systems with a far-distanced return conductor. Current ratings for control cables HD 627 S1 3 3 Number of loaded cores laying in ground laying in air Cross-section, mm 2 Current ratings in Ampere (A) 1, , The values are referred to the following basic conditions: Laying in ground Laying in air Ground temperature at installation depth: 20 o C Ambient temperature: 30 o C Load factor: 0,7 Load factor: 1,0 Soil-thermal resistivity of moist area: 1,0 k m/w Arrangement: free in air, protection against direct solar radiation, no Soil-thermal resistivity of dry area: 2,5 k m/w external heat sources, unrestricted dissipation Laying depth: 0,7 m of heat. Correction factors for various ambient air temperatures Ambient temperature, C Rating factor 1,15 1,12 1,08 1,04 1,00 0,96 0,91 0,87 0,82 The conversion factors are to be used for laying the cables in ground or in air, to the values given in above tables Number of loaded cores Laying in ground Laying in air 5 0,70 0,75 7 0,60 0, ,50 0, ,45 0, ,40 0, ,35 0, ,30 0, ,25 0,30 Note: valid for cross-section 1,5 to 10 mm 2. POWER AND CONTROL CABLES 56
57 TYPE: AXMK 0,6/1 kv XLPE insulated and PVC sheathed power cables NORM: SFS 4879, HD 603-5D, IEC CONSTRUCTION: Conductor: Insulation: Outer Sheath: Colour of sheath: 16 mm2: Sector shaped, solid aluminium conductor, mm2: Sector shaped, stranded and compacted aluminium conductor. XLPE compound PVC compound, black yellow and green black black brown Maximum conductor operating temperature: + 90 o C Lowest installation temperature: -15 o C Maximum short-circuit conductor temperature: +250 o C Application: Laying in air and ground DESCRIPTION UNIT DETAILS Number and nominal cross-section nx of the conductors mm2 1) 1) Conductor Insulation (XLPE) thickness: - minimum average (nominal) - minimum at a point Outer sheath (extruded PVC) thickness: - minimum average (nominal), - minimum at a point overall diameter of completed cable weight of: - complete cable - aluminium mm mm mm mm CONSTRUCTION DATA Solid Stranded and compacted sector shaped aluminium conductor mm kg/km kg/km DELIVERY DATA Length per drum m Diameter of wooden drum mm Type of drum Weight of heaviest reel, including cable kg ELECTRICAL DATA Maximum D.C. resistance of phase conductor at 20 C A.C. resistance of phase conductor at 65 C A.C. resistance of phase conductor at 90 C Operating inductance mh/km Induction reactance Mutual capacitance µf/km Charging current A/km Earth fault current A/km MECHANICAL DATA Recommended min. bending radius: during installation m and smoothly as a single bend to the same direction m Maximum permissible pulling force: by pulling-head N by cable stocking N POWER AND CONTROL CABLES 57
58 DESCRIPTION UNIT DETAILS Number and nominal cross-section nx of the conductors mm2 1) 1) SHORT CIRCUIT CURRENTS Maximum permissible thermal shortcircuit Current for 1 sec. ka Phase conductor 90 C 250 C AMPACITY 2) In air A In earth A DESCRIPTION UNIT DETAILS n x mm2 1) Number and nominal cross-section of the conductors CONSTRUCTION DATA Conductor - Stranded and compacted sector shaped aluminium conductor Insulation (XLPE) thickness: - minimum average (nominal) mm minimum at a point mm Outer sheath (extruded PVC) thickness: - minimum average (nominal), mm minimum at a point mm overall diameter of by cable stocking N SHORT CIRCUIT CURRENTS Maximum permissible thermal shortcircuit Current for 1 sec. Phase conductor ka AMPACITY 2) In air A In earth A ) Acc. to IEC standard only. 2) Current rating guideline (Calculated according to IEC Publ. 287 and the following conditions) Ground temperature max. 20 C Ambient air temperature max. 25 C Laying depth 0.70m Ground thermal resistivity 1.0 K m/w mm completed cable weight of: - complete cable kg/km aluminium kg/km DELIVERY DATA Length per drum m Diameter of wooden drum mm Type of drum M 22M Weight of heaviest reel, including cable kg ELECTRICAL DATA Maximum D.C. resistance of phase conductor at 20 C A.C. resistance of phase conductor at 65 C A.C. resistance of phase conductor at 90 C Operating inductance mh/km Induction reactance Mutual capacitance µf/km Charging current A/km Earth fault current A/km MECHANICAL DATA Recommended min. bending radius: during installation m and smoothly as a single bend to the same direction m Maximum permissible pulling force: by pulling-head N POWER AND CONTROL CABLES 58
59 LV POWER CABLES WITH CONCENTRIC COPPER CONDUCTOR NYCY, MCMK, AMCMK, MCMO TYPE: NYCY 0,6/1 kv PVC insulated and PVC sheathed power and control cable with concentric copper conductor NORM: DIN VDE and DIN VDE CONSTRUCTION: Conductor: plain annealed copper circular solid class 1(RE), circular or circular compacted stranded conductor class 2 (RM) acc. to DIN EN Insulation: special PVC compound type DIV4 acc. to HD Inner sheath: Concentric conductor: special thermoplastic compound round copper wires and copper tape Sheath: special PVC compound type DMV5 acc. to HD Colour of sheath: black DIN VDE , HD 308 S2 twin blue, brown 3-core brown, black, grey 3 core:* blue, brown, black 4-core blue, brown, black, grey 5-core blue, brown, black, grey, black more 5-core: * For certain application only. black with numbering Maximum conductor operating temperature: +70 o C -30 o C Lowest installation temperature: -5 o C Maximum short-circuit conductor temperature: o C Minimum bending radius: 12 x D multicore cables, D overall diameter Max. permissible tensile stress with cable grip for Cu-conductor: 50 N/mm 2, calculated for the nominal sum of cross- Flame retardant: DIN EN The product is conformed with the RoHS Direktive 2002/95/CE, Low-Voltage Direktive 73/23/EEC and 93/68/ECC Application: PVC insulated and sheathed power and auxiliary control cables for the supply of electrical energy. Special for installations in the open air, in underground and water, indoors, in cable ducts. The concentric conductor is allowed to use as neutral, protective or earthed conductor. Simultaneously, this also is permitted to apply as a screen for example earthconnected protection against contact. Standard length cable packing: 500 or 1000 m on drums. Other forms of packing and delivery are available on request. POWER AND CONTROL CABLES 59
60 Number and crosssectional area of conductor Nominal thickness of insulation Nominal thickness of sheath overall diameter net weight of cables Maximum conductor resistance at 20 o C nxmm 2 mm mm mm kg/km 2 x 1,5RE / 1,5 0,8 1,8 12, ,1 / 12,1 2 x 2,5RE / 2,5 0,8 1,8 13, ,41 / 7,41 2 x 4RE / 4 1,0 1,8 15, ,61 / 4,61 2 x 6RE / 6 1,0 1,8 16, ,08 / 3,08 2 x 10RE / 10 1,0 1,8 18, ,83 / 1,83 2 x 16RE / 16 1,0 1,8 20, ,15 / 1,15 2 x 25RM / 16 1,2 1,8 25, ,727 / 1,15 2 x 35RM / 16 1,2 1,8 27, ,524 / 1,15 3 x 1,5RE / 1,5 0,8 1,8 12, ,1 / 12,1 3 x 2,5RE / 2,5 0,8 1,8 13, ,41 / 7,41 3 x 4RE / 4 1,0 1,8 15, ,61 / 4,61 3 x 6RE / 6 1,0 1,8 17, ,08 / 3,08 3 x 10RE / 10 1,0 1,8 19, ,83 / 1,83 3 x 16RE / 16 1,0 1,8 21, ,15 / 1,15 3 x 25RM / 16 1,2 1,8 26, ,727 / 1,15 3 x 35RM / 16 1,2 1,8 28, ,524 / 1,15 4 x 1,5RE / 1,5 0,8 1,8 13, ,1 / 12,1 4 x 2,5RE / 2,5 0,8 1,8 14, ,41 / 7,41 4 x 4RE / 4 1,0 1,8 16, ,61 / 4,61 4 x 6RE / 6 1,0 1,8 18, ,08 / 3,08 4 x 10RE / 10 1,0 1,8 20, ,83 / 1,83 4 x 16RE / 16 1,0 1,8 23, ,15 / 1,15 4 x 25RM / 16 1,2 1,8 28, ,727 / 1,15 4 x 35RM / 16 1,2 1,9 31, ,524 / 1,15 5 x 1,5RE / 1,5 0,8 1,8 14, ,1 / 12,1 5 x 2,5RE / 2,5 0,8 1,8 15, ,41 / 7,41 5 x 4RE / 4 1,0 1,8 18, ,61 / 4,61 5 x 6RE / 6 1,0 1,8 19, ,08 / 3,08 5 x 10RE / 10 1,0 1,8 22, ,83 / 1,83 5 x 16RE / 16 1,0 1,8 24, ,15 / 1,15 5 x 25RM / 16 1,2 1,8 31, ,727 / 1,15 7 x 1,5RE / 2,5 0,8 1,8 15, ,1 / 7,41 7 x 2,5RE / 2,5 0,8 1,8 16, ,41 / 7,41 7 x 4RE / 4 1,0 1,8 19, ,61 / 4,61 8 x 1,5RE / 2,5 0,8 1,8 16, ,1 / 7,41 9 x 1,5RE / 2,5 0,8 1,8 17, ,1 / 7,41 10 x 1,5RE / 2,5 0,8 1,8 18, ,1 / 7,41 10 x 2,5RE / 4 0,8 1,8 20, ,41 / 4,61 10 x 4RE / 6 1,0 1,8 23, ,61 / 3,08 12 x 1,5RE / 2,5 0,8 1,8 18, ,1 / 7,41 12 x 2,5RE / 4 0,8 1,8 20, ,41 / 4,61 12 x 4RE / 6 1,0 1,8 24, ,61 / 3,08 14 x 1,5RE / 2,5 0,8 1,8 19, ,1 / 7,41 14 x 2,5RE / 6 0,8 1,8 21, ,41 / 3,08 14 x 4RE / 6 1,0 1,8 25, ,61 / 3,08 16 x 1,5RE / 4 0,8 1,8 20, ,1 / 4,61 16 x 2,5RE / 6 0,8 1,8 22, ,41 / 3,08 19 x 1,5RE / 4 0,8 1,8 21, ,1 / 4,61 19 x 2,5RE / 6 0,8 1,8 23, ,41 / 3,08 19 x 4RE / 10 1,0 1,8 28, ,61 / 1,83 21 x 1,5RE / 6 0,8 1,8 22, ,1 / 3,08 21 x 2,5RE / 10 0,8 1,8 24, ,41 / 1,83 24 x 1,5RE / 6 0,8 1,8 24, ,1 / 3,08 24 x 2,5RE / 10 0,8 1,8 27, ,41 / 1,83 30 x 1,5RE / 6 0,8 1,8 25, ,1 / 3,08 30 x 2,5RE / 10 0,8 1,8 28, ,41 / 1,83 37 x 1,5RE / 10 0,8 1,8 27, ,1 / 1,83 40 x 1,5RE / 10 0,8 1,8 28, ,1 / 1,83 40 x 2,5RE / 10 0,8 1,9 31, ,41 / 1,83 POWER AND CONTROL CABLES 60
61 Current ratings* Operating temperature at conductor 70 o o C, ground temperature 20 o C Number of loaded cores 3 3 Laying in ground Laying in air Cross-section, mm 2 Current ratings in Ampere (A) 1, ,5 2, The values are referred to the following basic conditions: Laying in ground Laying in air Ground temperature at installation depth: 20 o C Ambient temperature: 30 o C Load factor: 0,7 Load factor: 1,0 Soil-thermal resistivity of moist area: 1,0 k. m/w Arrangement: free in air, protection against direct solar radiation, no external Soil-thermal resistivity of dry area: 2,5 k. m/w heat sources, unrestricted dissipation Laying depth: 0,7 m of heat. Correction factors for various ambient air temperatures Ambient temperature, C) Rating factor 1,22 1,17 1,12 1,06 1,00 0,94 0,87 0,79 0,71 Current ratings for control cables HD 627 S1 Number of loaded cores 3 3 Laying in ground Laying in air Cross-section, mm 2 Current ratings in Ampere (A) 1, ,5 2, The conversion factors are to be used for laying the cables in ground or in air, to the values given in above tables Number of loaded cores Laying in ground Laying in air 5 0,70 0,75 7 0,60 0, ,50 0, ,45 0, ,40 0, ,35 0, ,30 0, ,25 0,30 POWER AND CONTROL CABLES 61
62 TYPE: MCMK 0,6/1 kv PVC insulated and PVC sheathed power cable with concentric copper conductor NORM: SFS 4880, HD 603 S1-3F CONSTRUCTION: Conductor: plain annealed copper circular solid class 1(RE), circular or circular compacted stranded conductor class 2 (RM) or stranded sector shaped conductor class 2 (SM) acc. to EN Insulation: special PVC compound type DIV6 acc. to HD Inner sheath: Concentric conductor: special thermoplastic compound round copper wires and copper tape Sheath: special PVC compound type DMV9 acc. to HD Colour of sheath: black Colour code: to SFS 4880 Maximum conductor operating temperature: +70 o C -30 o C Lowest installation temperature: -15 o C Maximum short-circuit conductor temperature: o C Minimum bending radius: 15 x D for single core cables and 12 x D for multicore cables, D overall cable diameter Max. permissible tensile stress with cable grip for Cu-conductor: 50 N/mm 2, calculated for the nominal sum of cross- Flame retardant: EN (HD 405.1), IEC The product is conformed with the RoHS Direktive 2002/95/CE, Low-Voltage Direktive 73/23/EEC and 93/68/ECC Application: installations in the open air, in underground, indoors, in cable ducts. The concentric conductor is allowed to use as neutral, PE-conductor, PEN-conductor, or as a screen, in accordance with national regulations. Standard length cable packing: 500 m on drums. Other forms of packing and delivery are available on request. Number and crosssectional area of conductor Nominal thickness of insulation Nominal thickness of sheath overall diameter net weight of cables Maximum conductor resistance at temperature 20 o C nxmm 2 mm mm mm kg/km 2 x 1,5RE / 1,5 0,8 1,8 12, ,1 / 12,1 2 x 2,5RE / 2,5 0,8 1,8 13, ,41 / 7,41 2 x 4RE / 4* 1,0 1,8 14, ,61 / 4,61 2 x 6RE / 6 1,0 1,8 16, ,08 / 3,08 2 x 10RE / 10 1,0 1,8 17, ,83 / 1,83 3 x 1,5RE / 1,5 0,8 1,8 12, ,1 / 12,1 3 x 2,5RE / 2,5 0,8 1,8 13, ,41 / 7,41 3 x 4RE / 4* 1,0 1,8 15, ,61 / 4,61 3 x 6RE / 6 1,0 1,8 16, ,08 / 3,08 3 x 10RE / 10 1,0 1,8 18, ,83 / 1,83 3 x 16RE / 16 1,0 1,8 20, ,15 / 1,15 3 x 25RM / 16 1,2 1,8 25, ,727 / 1,15 3 x 35RM / 16 1,2 1,8 27, ,524 / 1,15 3 x 50SM / 25 1,4 1,9 28, ,367/ 0,727 3 x 70SM / 35 1,4 2,0 32, ,268 / 0,524 3 x 95SM / 50 1,6 2,2 37, ,193 / 0,387 3 x 120SM / 70 1,6 2,3 39, ,153 / 0,268 3 x 150SM / 70 1,8 2,4 44, ,124 / 0,268 3 x 185SM / 95 2,0 2,6 49, ,0991 / 0,193 3 x 240SM / 120 2,2 2,9 55, ,0754 / 0,153 POWER AND CONTROL CABLES 62
63 4 x 1,5RE / 1,5 0,8 1,8 13, ,1 / 12,1 4 x 2,5RE / 2,5 0,8 1,8 14, ,41 / 7,41 4 x 4RE / 4* 1,0 1,8 16, ,61 / 4,61 4 x 6RE / 6 1,0 1,8 17, ,08 / 3,08 4 x 10RE / 10 1,0 1,8 19, ,83 / 1,83 4 x 16RE / 16 1,0 1,8 22, ,15 / 1,15 4 x 25RM / 16* 1,2 1,8 27, ,727 / 1,15 4 x 35RM / 16* 1,2 1,9 30, ,524 / 1,15 4 x 50SM / 25* 1,4 2,0 32, ,367/ 0,727 * Adapted to SFS 4880 TYPE: AMCMK 0,6/1 kv PVC insulated cables with concentric conductor and PVC sheath NORM: SFS 4880, HD 603-3F CONSTRUCTION: Conductors: Aluminium stranded sector shaped class 2 (SM) acc. to HD 383 Insulation: PVC compound type DIV6 According to HD 308.S2 4-core: blue, black, black, brown Laying up: Insulated conductors are stranded together Inner covering: Concentric conductor: Outer sheath: Lapped Copper wires and copper tape helically wounded Black PVC compound type DMV9 Flame retardant: IEC Maximum conductor operating temperature: C Maximum short-circuit conductor temperature: C for cross-sectional area 300 mm 2 and C for cross-sectional area > 300 mm 2 Minimum bending radius: 12xDfor multi conductor D overall diameter of the cable Test voltage of complete cable: 4kVAC, 5 min. Number and crosssectional area of conductor Nominal thickness of insulation Nominal thickness of outer sheath overall diameter weight of cables Maximum conductor resistanceat 20 o C nxmm 2 mm mm mm 4x35SM / 16 1,2 1,8 28, ,868 / 1,15 4x50SM / 15 1,4 2,0 31, ,641 / 1,20 4x70SM / 21 1,4 2,1 37, ,443 / 0,868 4x95SM / 29 1,6 2,3 41, ,320 / 0,641 4x120SM / 41 1,6 2,4 44, ,253 / 0,443 4x150SM / 41 1,8 2,6 48, ,206 / 0,443 4x185SM / 57 2,0 2,7 55, ,164 / 0,320 4x240SM / 72 2,2 3,0 62, ,125 / 0,253 POWER AND CONTROL CABLES 63
64 TYPE: MCMO 450/750 kv PVC insulated and PVC sheathed control cable with a protecting concentric copper conductor NORM: HD 627-4D* CONSTRUCTION: Conductors: plain annealed copper circular solid class 1 acc. to EN Insulation: Inner covering: Concentric conductor: Separator: Sheath: black lead free PVC compound type TI1 numbering layer of round copper wires with a copper tape polyester tape black lead free PVC compound type TM1 Maximum conductor operating temperature: +70 o C -15 o C -30 o C Maximum short-circuit conductor temperature: o C Max. permissible tensile stress with cable grip for Cu-conductor: 50 N/mm 2, calculated for the nominal sum of cross- Flame propagation: EN Minimum bending radius: 12 x D for multicore cables, D overall cable diameter The product is conformed with the RoHS Direktive 2002/95/CE, Low-Voltage Direktive 73/23/EEC and 93/68/ECC Application: installations in measuring, control and signalling circuits. Standard length cable packing: 500 m on drums. Other forms of packing and delivery are available on request. Number and crosssectional area of conductor / concentric conductor Nominal thickness of insulation Minimum thickness of sheath overall diameter net weight of cables Maximum resistance of concentric conductor at 20 o C nxmm 2 mm mm mm kg/km 7 x 1,5 / 6 0,7 1,5 14, ,08 12 x 1,5 / 6 0,7 1,5 18, ,08 19 x 1,5 / 6 0,7 1,6 21, ,08 27 x 1,5 / 6 0,7 1,7 24, ,08 37 x 1,5 / 10 0,7 1,8 27, ,83 7 x 2,5 / 6 0,8 1,5 16, ,08 12 x 2,5 / 6 0,8 1,6 20, ,08 19 x 2,5 / 6 0,8 1,7 23, ,08 27 x 2,5 / 10 0,8 1,8 27, ,83 37 x 2,5 / 10 0,8 1,9 30, ,83 * We can also produce cable MCMO with protecting concentric copper conductor 1,5 mm 2 and 2,5 mm 2 POWER AND CONTROL CABLES 64
65 HALOGEN-FREE LOW SMOKE POWER CABLES N2XH, N2XCH TYPE: N2XH 0,6/1 kv Halogen- free low smoke power cables NORM: DIN VDE CONSTRUCTION: Conductor: Insulation: Inner covering: Sheath: Colour of sheath: bare annealed copper conductor, circular solid class 1 (RE) or circular or circular compacted stranded class 2 (RM) or stranded sector - shaped conductor class 2 (SM) acc. to EN cross-linked polyethylene thermoplastic halogen - free compound type HM4 acc. to HD 604 S1 black DIN VDE , HD 308 S2 without protective conductor with protective conductor 1-core black green-yellow 2-core blue, brown 3-core brown, black, grey green-yellow, blue, brown 3 core* blue, brown, black 4-core blue, brown, black, grey green-yellow, brown, black, grey 4-core* green-yellow, blue, brown, black 5-core blue, brown, black, grey, black green-yellow, blue, brown, black, grey more 5-core * For certain application only. black with numbering green-yellow, others cores black with numbering Maximum conductor operating temperature: +90 o C -30 o C Lowest installation temperature: -5 o C Maximum short-circuit conductor temperature: +250 o C Minimum bending radius: Maximum permissible tensile stress with cable grip for Cu-conductor: 50 N/mm 2 Flame retardant: VDE , IEC Category C Smoke density: VDE , IEC : light transmittance values > 70% Gases evolved during combustion: DIN EN 50267, IEC : ph 100 S/cm The product is conformed with the RoHS Direktive 2002/95/CE, Low-Voltage Direktive 73/23/EEC and 93/68/ECC Application: XLPE insulated and halogen-free thermoplastic compound sheathed power and auxiliary emissions of smoke and toxic fumes create a potential threat (hotels, airports, underground stations, reilway stations, hospitals, banks, theaters etc.) Not suitable for use in water. Standard length cable packing: 500 or 1000m on drums. Other forms of packing and delivery are available on request. Number and crosssectional area of conductor Nominal thickness of insulation Nominal thickness of sheath overall diameter net weight of cables Maximum conductor resistance at 20 o C n x mm 2 mm mm mm 1 x 1,5RE 0,7 1,2 5, ,1 1 x 2,5RE 0,7 1,2 5,5 51 7,41 1 x 4RE 0,7 1,2 6,0 67 4,61 1 x 6RE 0,7 1,2 6,5 88 3,08 POWER AND CONTROL CABLES 65
66 Number and crosssectional area of conductor Nominal thickness of insulation Nominal thickness of sheath overall diameter net weight of cables Maximum conductor resistance at 20 o C n x mm 2 mm mm mm 1 x 10RE 0,7 1,2 7, ,83 1 x 16RE 0,7 1,2 8, ,15 1 x 25RM 0,9 1,2 10, ,727 1 x 35RM 0,9 1,2 11, ,524 1 x 50RM 1,0 1,2 12, ,387 1 x 70RM 1,1 1,2 14, ,268 1 x 95RM 1,1 1,3 16, ,193 1 x 120RM 1,2 1,3 18, ,153 1 x 150RM 1,4 1,3 20, ,124 1 x 185RM 1,6 1,4 22, , x 240RM 1,7 1,4 25, , x 300RM 1,8 1,5 28, , x 400RM 2,0 1,5 32, , x 500RM 2,2 1,6 36, , x 1,5RE 0,7 1,2 8, ,1 2 x 2,5RE 0,7 1,2 9, ,41 2 x 4RE 0,7 1,2 10, ,61 2 x 6RE 0,7 1,2 11, ,08 2 x 10RE 0,7 1,2 13, ,83 2 x 16RE 0,7 1,3 15, ,15 3 x 1,5RE 0,7 1,2 9, ,1 3 x 2,5RE 0,7 1,2 10, ,41 3 x 4RE 0,7 1,2 11, ,61 3 x 6RE 0,7 1,2 12, ,08 3 x 10RE 0,7 1,2 13, ,83 3 x 16RE 0,7 1,3 16, ,15 3 x 25RM 0,9 1,3 20, ,727 3 x 35RM 0,9 1,4 23, ,524 3 x 35SM 0,9 1,4 20, ,524 3 x 50SM 1,0 1,5 23, ,387 3 x 70SM 1,1 1,5 27, ,268 3 x 95SM 1,1 1,6 30, ,193 3 x 120SM 1,2 1,7 33, ,153 3 x 150SM 1,4 1,7 37, ,124 3 x 185SM 1,6 1,8 41, , x 240SM 1,7 1,9 46, , x 25RM/16RE 0,9 / 0,7 1,4 21, ,727 / 1,15 3 x 35RM/16RE 0,9 / 0,7 1,4 23, ,524 / 1,15 3 x 50SM/25RM 1,0 / 0,9 1,5 26, ,387 / 0,727 3 x 70SM/35SM 1,1 / 0,9 1,5 29, ,268 / 0,524 3 x 95SM/50SM 1,1 / 1,0 1,6 33, ,193 / 0,387 3 x 120SM/70SM 1,2 / 1,4 1,7 36, ,153 / 0,268 3 x 150SM/70SM 1,4 / 1,4 1,8 40, ,124 / 0,268 3 x 185SM/95SM 1,6 / 1,1 1,9 44, ,0991/ 0,193 3 x 240SM/120SM 1,7 / 1,2 2,0 50, ,0754 / 0,153 4 x 1,5RE 0,7 1,2 10, ,1 4 x 2,5RE 0,7 1,2 11, ,41 4 x 4RE 0,7 1,2 12, ,61 4 x 6RE 0,7 1,2 13, ,08 4 x 10RE 0,7 1,3 15, ,83 4 x 16RE 0,7 1,3 17, ,15 4 x 25RM 0,9 1,4 22, ,727 4 x 35RM 0,9 1,4 25, ,524 4 x 35SM 0,9 1,4 23, ,524 4 x 50SM 1,0 1,5 26, ,387 4 x 70SM 1,1 1,6 30, ,268 4 x 95SM 1,1 1,7 34, ,193 4 x 120SM 1,2 1,7 38, ,153 4 x 150SM 1,4 1,8 42, ,124 4 x 185SM 1,6 1,9 46, , x 240SM 1,7 2,0 52, , x 1,5RE 0,7 1,2 10, ,1 POWER AND CONTROL CABLES 66
67 Number and crosssectional area of conductor Nominal thickness of insulation Nominal thickness of sheath overall diameter net weight of cables Maximum conductor resistance at 20 o C n x mm 2 mm mm mm 5 x 2,5RE 0,7 1,2 11, ,41 5 x 4RE 0,7 1,2 13, ,61 5 x 6RE 0,7 1,2 14, ,08 5 x 10RE 0,7 1,3 16, ,83 5 x 16RE 0,7 1,3 19, ,15 7 x 1,5RE 0,7 1,2 11, ,1 7 x 2,5RE 0,7 1,2 12, ,41 7 x 4RE 0,7 1,2 14, ,61 9 x 1,5RE 0,7 1,2 13, ,1 10 x 1,5RE 0,7 1,2 14, ,1 10 x 2,5RE 0,7 1,3 16, ,41 10 x 4RE 0,7 1,3 18, ,61 12 x 1,5RE 0,7 1,2 14, ,1 12 x 2,5RE 0,7 1,3 16, ,41 12 x 4RE 0,7 1,3 18, ,61 14 x 1,5RE 0,7 1,3 15, ,1 14 x 2,5RE 0,7 1,3 17, ,41 14 x 4RE 0,7 1,3 19, ,61 15 x 2,5RE 0,7 1,3 18, ,41 16 x 1,5RE 0,7 1,3 17, ,1 17 x 4RE 0,7 1,4 21, ,61 19 x 1,5RE 0,7 1,3 17, ,1 19 x 2,5RE 0,7 1,3 19, ,41 19 x 4RE 0,7 1,4 21, ,61 20 x 2,5RE 0,7 1,4 20, ,41 24 x 1,5RE 0,7 1,4 20, ,1 24 x 2,5RE 0,7 1,4 22, ,41 30 x 1,5RE 0,7 1,4 21, ,1 30 x 2,5RE 0,7 1,4 23, ,41 37 x 1,5RE 0,7 1,4 23, ,1 40 x 1,5RE 0,7 1,4 23, ,1 40 x 2,5RE 0,7 1,5 26, ,41 Current ratings* Operating temperature at conductor 70 o o C Installation Number of loaded cores laying in air Cross-section, mm 2 Current ratings in Ampere (A) 1, , ) Rated current for direct current systems with a far-distanced return conductor. POWER AND CONTROL CABLES 67
68 Correction factors for various ambient air temperatures Ambient temperature, C) Rating factor 1,22 1,17 1,12 1,06 1,00 0,94 0,87 0,79 0,71 Current ratings for control cables HD 627 S1 Number of loaded cores 3 laying in air Cross-section, mm 2 Current ratings in Ampere (A) 1,5 24 2, The conversion factors are to be used for laying the cables in ground or in air, to the values given in above tables Number of loaded cores Laying in air 5 0,75 7 0, , , , , , ,30 TYPE: N2XCH 0,6/1 kv Halogen- free low smoke power cables with copper concentric conductor NORM: DIN VDE CONSTRUCTION: Conductor: Insulation: Inner covering: Separator: Sheath: Colour of sheath: bare annealed copper conductor, circular solid class 1 (RE) or circular or circular compacted stranded class 2 (RM) or stranded sector - shaped conductor class 2 (SM) acc. to EN cross-linked polyethylene tape thermoplastic halogen - free compound type HM4 acc. to HD 604 S1 black acc. to HD 308 S2 or HD 186 without protective conductor 2-core blue, brown 3-core brown, black, grey 3 core* blue, brown, black 4-core blue, brown, black, grey 5-core blue, brown, black, grey, black * For certain application only. black with numbering Maximum conductor operating temperature: +90 o C -30 o C Lowest installation temperature: -5 o C Maximum short-circuit conductor temperature: +250 o C Minimum bending radius: Maximum permissible tensile stress with cable grip for Cu-conductor: 50 N/mm 2 Flame retardant: VDE , IEC Category C POWER AND CONTROL CABLES 68
69 Smoke density: VDE , IEC : light transmittance values > 70% Gases evolved during combustion: The product is conformed with the RoHS Direktive 2002/95/CE, Low-Voltage Direktive 73/23/EEC and 93/68/ECC Application: XLPE insulated and halogen-free thermoplastic compound sheathed power and auxiliary emissions of smoke and toxic fumes create a potential threat (hotels, airports, underground stations, reilway stations, hospitals, banks, theaters etc.). The concentric conductor with a traverse spiral of copper serves as a screen and can be used as PE or PEN conductor. Not suitable for use in water. Standard length cable packing: 500 or 100 m on drums. Other forms of packing and delivery are available on request. Number and crosssectional area of conductor Nominal thickness of insulation Nominal thickness of sheath overall diameter net weight of cables Maximum conductor resistance at 20 o C n x mm 2 mm mm mm 2 x 1.5RE/1,5 0,7 1,2 10, ,1 / 12,1 2 x 2.5RE/2,5 0,7 1,2 11, ,41 / 7,41 2 x 4RE/4 0,7 1,2 12, ,61 / 4,61 2 x 6RE/6 0,7 1,2 14, ,08 / 3,08 2 x 10RE/10 0,7 1,2 15, ,83 / 1,83 2 x 16RE/16 0,7 1,3 18, ,15 / 1,15 2 x 16RM/16 0,7 1,3 19, ,15 / 1,15 2 x 25RM/16 0,9 1,3 22, ,727 / 1,15 3 x 1,5RE/1,5 0,7 1,2 11, ,1 / 12,1 3 x 2,5RE/2,5 0,7 1,2 12, ,41 / 7,41 3 x 4RE/4 0,7 1,2 13, ,61 / 4,61 3 x 6RE/6 0,7 1,2 14, ,08 / 3,08 3 x 10RE/10 0,7 1,3 16, ,83 / 1,83 3 x 16RE/16 0,7 1,3 19, ,15 / 1,15 3 x 16RM/16 0,7 1,3 20, ,15 / 1,15 3 x 25RM/16 0,9 1,4 24, ,727 / 1,15 3 x 35RM/16 0,9 1,4 26, ,524 / 1,15 3 x 50 SM /25 1,0 1,5 29, ,367/ 0,727 3 x 70 SM /35 1,1 1,6 34, ,268 / 0,524 3 x 95 SM /50 1,1 1,6 37, ,193 / 0,387 3 x 120 SM /70 1,2 1,7 42, ,153 / 0,268 3 x 150 SM /70 1,4 1,8 46, ,124 / 0,268 3 x 185 SM /95 1,6 1,9 51, ,0991 / 0,193 3 x 240 SM /120 1,7 2,0 56, ,0754 / 0,153 4 x 1,5RE/1,5 0,7 1,2 11, ,1 / 12,1 4 x 2,5RE/2,5 0,7 1,2 12, ,41 / 7,41 4 x 4RE/4 0,7 1,2 14, ,61 / 4,61 4 x 6RE/6 0,7 1,2 15, ,08 / 3,08 4 x 10RE/10 0,7 1,3 18, ,83 / 1,83 4 x 16RE/16 0,7 1,3 20, ,15 / 1,15 4 x 16RM/16 0,7 1,3 21, ,15 / 1,15 4 x 25RM/16 0,9 1,4 26, ,727 / 1,15 4 x 35RM/16 0,9 1,5 29, ,524 / 1,15 4 x 35 SM /16 0,9 1,5 26, ,524 / 1,15 4 x 50 SM /25 1,0 1,5 29, ,367/ 0,727 4 x 70 SM /35 1,1 1,6 34, ,268 / 0,524 4 x 95 SM /50 1,1 1,7 38, ,193 / 0,387 4 x 120 SM /70 1,2 1,8 42, ,153 / 0,268 4 x 150 SM /70 1,4 1,9 47, ,124 / 0,268 4 x 185 SM /95 1,6 2,0 51, ,0991 / 0,193 4 x 240 SM /120 1,7 2,1 57, ,0754 / 0,153 7 x 1,5RE/2,5 0,7 1,2 13, ,1 / 7,41 7 x 2,5RE/2,5 0,7 1,2 14, ,41 / 7,41 7 x 4RE/4 0,7 1,3 16, ,61 / 4,61 10 x 1,5RE/2,5 0,7 1,3 16, ,1 / 7,41 10 x 2,5RE/4 0,7 1,3 18, ,41 / 4,61 10 x 4RE/6 0,7 1,3 20, ,61 / 3,08 12 x 1,5RE/2,5 0,7 1,3 16, ,1 / 7,41 12 x 2,5RE/4 0,7 1,3 18, ,41 / 4,61 12 x 4RE/6 0,7 1,3 21, ,61 / 3,08 POWER AND CONTROL CABLES 69
70 14 x 1,5RE/2,5 0,7 1,3 17, ,1 / 7,41 14 x 2,5RE/4 0,7 1,3 19, ,41 / 4,61 14 x 4RE/6 0,7 1,4 22, ,61 / 3,08 15 x 1,5RE/2,5 0,7 1,3 18, ,1 / 7,41 16 x 1,5RE/4 0,7 1,3 18, ,1 / 4,61 16 x 2,5RE/6 0,7 1,3 20, ,41 / 3,08 19 x 1,5RE/4 0,7 1,3 19, ,1 / 4,61 19 x 2,5RE/6 0,7 1,4 22, ,41 / 3,08 19 x 4RE/10 0,7 1,4 24, ,61 / 1,83 24 x 1,5RE/6 0,7 1,4 22, ,1 / 3,08 24 x 2,5RE/10 0,7 1,4 25, ,41 / 1,83 30 x 1,5RE/6 0,7 1,4 23, ,1 / 3,08 30 x 1,5RE/10 0,7 1,4 24, ,1 / 1,83 30 x 2,5RE/10 0,7 1,5 26, ,41 / 1,83 40 x 1,5RE/10 0,7 1,5 26, ,1 / 1,83 40 x 2,5RE/10 0,7 1,5 29, ,41 / 1,83 Current ratings* Operating temperature at conductor 70 o o C Installation Number of loaded cores 3 3 laying in air Cross-section, mm 2 Current ratings in Ampere (A) 1, , ) Rated current for direct current systems with a far-distanced return conductor. Correction factors for various ambient air temperatures Ambient temperature, C) Rating factor 1,22 1,17 1,12 1,06 1,00 0,94 0,87 0,79 0,71 Current ratings for control cables HD 627 S1 Number of loaded cores 3 laying in air Cross-section, mm 2 Current ratings in Ampere (A) 1,5 25 2, The conversion factors are to be used for laying the cables in ground or in air, to the values given in above tables Number of loaded cores Laying in air 5 0,75 7 0, , , , , , ,30 POWER AND CONTROL CABLES 70
71 HALOGEN-FREE LOW SMOKE FIRE RESISTANT POWER CABLES (N)HXH FE180/E 30, (N)HXCH FE180/E 30, (N)HXH FE180/E 90, (N)HXCH FE180/E 90 TYPE: FLAME-X 950, (N)HXH FE180/E 30 0,6/1 kv NORM: DIN VDE 0266, DIN CONSTRUCTION: Conductor: Insulation: Inner covering: Sheath: Colour of sheath: bare copper conductor, circular solid class 1 (RE) or stranded circular or circular compacted class 2 (RM) acc. to EN thermoplastic halogen- free compound type HM4 acc. to HD 604 S1 orange DIN VDE , HD 308 S2 1-core black green-yellow 2-core blue, brown 3-core brown, black, grey green-yellow, blue, brown 3 core* blue, brown, black 4-core blue, brown, black, grey green-yellow, brown, black, grey 4-core* green-yellow, blue, brown, black 5-core blue, brown, black, grey, black green-yellow, blue, brown, black, grey more 5-core * For certain application only. black with numbering green-yellow, others cores black with numbering Maximum conductor operating temperature: +90 o C -30 o C Lowest installation temperature: -5 o C Maximum short-circuit conductor temperature: +250 o C Minimum bending radius: Maximum permissible tensile stress with cable grip for Cu-conductor: 50 N/mm 2 DIN VDE (800 o C, 180 min.), IEC System integrity E30: DIN (30 min.) Flame retardant: DIN VDE C, IEC Category A Smoke density: VDE , IEC : light transmittance values > 70% Gases evolved during combustion: VDE , IEC : ph 2,5 S/mm The product is conformed with the RoHS Direktive 2002/95/CE, Low-Voltage Direktive 73/23/EEC and 93/68/ECC Application: Fire resistant security cables for installation everywhere where high safety requirements hotels, underground railway systems, hospitals etc. Standard length cable packing: 500 m on drums. Other forms of packing and delivery are available on request. Number and cross-sectional area of conductor overall diameter net weight of cables n x mm 2 mm 1 x 1,5 RE 6, ,1 1 x 2,5 RE 6,7 69 7,41 1x4RE 7,2 87 4,61 1x6RE 7, ,08 Maximum conductor resistance at 20 o C POWER AND CONTROL CABLES 71
72 Number and cross-sectional area of conductor overall diameter net weight of cables n x mm 2 mm 1x10RE 8, ,83 1x16RM 9, ,15 1x25RM 11, ,727 1x35RM 12, ,524 1x50RM 14, ,387 1x70RM 15, ,268 1x95RM 18, ,193 1 x 120 RM 20, ,153 1 x 150 RM 22, ,124 1 x 185 RM 24, , x 240 RM 27, , x 300 RM 29, , x 1,5 RE 11, ,1 2 x 2,5 RE 12, ,41 2x4RE 13, ,61 2x6RE 14, ,08 2x10RE 15, ,83 2x16RM 18, ,15 2x25RM 22, ,727 3 x 1,5 RE 12, ,1 3 x 2,5 RE 12, ,41 3x4RE 13, ,61 3x6RE 14, ,08 3x10RE 16, ,83 3x16RM 19, ,15 3x25RM 23, ,727 3x35RM 25, ,524 3x50RM 29, ,387 3x70RM 33, ,268 3x95RM 38, ,193 3 x 120 RM 41, ,153 3 x 150 RM 46, ,124 3 x 185 RM 51, , x 240 RM 57, , x 1,5 RE 13, ,1 4 x 2,5 RE 13, ,41 4x4RE 15, ,61 4x6RE 16, ,08 4x10RE 18, ,83 4x16RM 21, ,15 4x25RM 25, ,727 4 x 35 RM 28, ,524 4x50RM 33, ,387 4x70RM 36, ,268 4x95RM 43, ,193 4 x 120 RM 46, ,153 4 x 150 RM 51, ,124 4 x 185 RM 57, , x 240 RM 64, , x 1,5 RE 14, ,1 5 x 2,5 RE 15, ,41 5x4RE 16, ,61 5x6RE 17, ,08 5x10RE 19, ,83 5x10RM 20, ,83 5x16RM 23, ,15 5x25RM 28, ,727 5x35RM 31, ,524 5 x 50 RM 36, ,387 5x70RM 40, ,268 5x95RM 47, ,193 5 x 120 RM 51, ,153 5 x 150 RM 57, ,124 Maximum conductor resistance at 20 o C POWER AND CONTROL CABLES 72
73 Number and cross-sectional area of conductor overall diameter net weight of cables n x mm 2 mm 5 x 185 RM 63, , x 240 RM 71, , x 1,5 RE 15, ,1 7 x 2,5 RE 16, ,41 7x4RM 18, ,61 10 x 1,5 RM 19, ,1 10 x 2,5 RM 21, ,41 12 x 1,5 RM 20, ,1 12 x 2,5 RM 22, ,41 14 x 1,5 RM 21, ,1 14 x 2,5 RM 23, ,41 16 x 1,5 RM 22, ,1 16 x 2,5 RM 24, ,41 19 x 1,5 RM 23, ,1 19 x 2,5 RM 25, ,41 24 x 1,5 RM 27, ,1 24 x 2,5 RM 29, ,41 30 x 1,5 RE 28, ,1 Maximum conductor resistance at 20 o C 30 x 2,5 RE 31, ,41 3 x 25RM/16RM 24, ,727 / 1,15 3 x 35RM/16RM 26, ,524 / 1,15 3 x 50RM/25RM 31, ,387 / 0,727 3 x 70RM/35RM 34, ,268 / 0,524 3 x 95RM/50RM 40, ,193 / 0,387 3 x 120RM/70RM 44, ,153 / 0,268 3 x 150RM/70RM 48, ,124 / 0,268 3 x 185RM/95RM 53, ,0991 / 0,193 3 x 240RM/120RM 59, ,0754 / 0,153 4 x 50RMC+25RMC 35, ,387 / 0,727 4 x 70RMC+35RMC 38, ,268 / 0,524 4 x 95RMC+50RMC 45, ,193 / 0,387 4 x 120RMC+70RMC 49, ,153 / 0,268 4 x 150RMC+70RMC 54, ,124 / 0,268 TYPE: FLAME-X 950, (N)HXCH FE180/E 30 0,6/1 kv NORM: DIN VDE 0266, DIN CONSTRUCTION: Conductor: Insulation: Inner covering: Concentric conductor: Separator: Sheath: Colour of sheath: bare copper conductor, circular solid class 1 (RE) or stranded circular or circular compacted class 2 (RM) acc. to EN inner layer - round copper wires, outer layer - copper tape tape thermoplastic halogen- free compound type HM4 acc. to HD 604 S1 orange DIN VDE , HD 308 S2 2-core blue, brown 3-core brown, black, grey 3 core* blue, brown, black 4-core blue, brown, black, grey more 7-core black with numbering * For certain application only. POWER AND CONTROL CABLES 73
74 Maximum conductor operating temperature: +90 o C -30 o C Lowest installation temperature: -5 o C Maximum short-circuit conductor temperature: +250 o C Minimum bending radius: Maximum permissible tensile stress with cable grip for Cu-conductor: 50 N/mm 2 DIN VDE (800 o C, 180 min.), IEC System integrity E30: DIN VDE (30 min.) Flame retardant: DIN VDE C, IEC Category A Smoke density: DIN VDE , IEC : light transmittance values > 70% Gases evolved during combustion: DIN EN (VDE ), IEC : ph 2,5 S/mm The product is conformed with the RoHS Direktive 2002/95/CE, Low-Voltage Direktive 73/23/EEC and 93/68/ECC Application: Fire resistant security cables for installation everywhere where high safety requirements hotels, underground railway systems, hospitals etc. Standard length cable packing: 500 m or 1000m on drums. Other forms of packing and delivery are available on request. Number and cross-sectional area of conductor overall diameter net weight of cables Maximum conductor resistance at 20 o C n x mm 2 mm 2 x 1,5 RE/1,5 13, ,1 / 12,1 2 x 2,5 RE/2,5 14, ,41 / 7,41 2x4RE/4 15, ,61 / 4,61 2x6RE/6 16, ,08 / 3,08 2 x 10 RE/10 18, ,83 / 1,83 2 x 16 RM/16 21, ,15 / 1,15 3 x 1,5 RE/1,5 14, ,1 / 12,1 3 x 2,5 RE/2,5 15, ,41 / 7,41 3x4RE/4 16, ,61 / 4,61 3x6RE/6 17, ,08 / 3,08 3 x 10 RE/10 19, ,83 / 1,83 3 x 16 RM/16 22, ,15 / 1,15 3 x 25 RM/16 26, ,727 / 1,15 3 x 35 RM/16 28, ,524 / 1,15 3 x 50 RM/25 32, ,387 / 0,727 3 x 70 RM/35 36, ,268 / 0,524 3 x 95 RM/50 42, ,193 / 0,387 3 x 120 RM/70 46, ,135 / 0,268 3 x 150 RM/70 51, ,124 / 0,268 3 x 185 RM/95 56, ,0991 / 0,193 3 x 240 RM/120 63, ,0754 / 0,153 4 x 1,5 RE/1,5 15, ,1 / 12,1 4 x 2,5 RE/2,5 16, ,41 / 7,41 4x4RE/4 17, ,61 / 4,61 4x6RE/6 19, ,08 / 3,08 4 x 10 RE/10 20, ,83 / 1,83 4 x 16 RM/16 24, ,15 / 1,15 4 x 25 RM/16 28, ,727 / 1,15 4 x 35 RM/16 31, ,524 / 1,15 4 x 50 RM/25 36, ,387 / 0,727 4 x 70 RM/35 40, ,268 / 0,524 4 x 95 RM/50 47, ,193 / 0,387 4 x 120 RM/70 51, ,153 / 0,268 4 x 150 RM/70 56, ,124 / 0,268 4 x 185 RM/95 61, ,0991 / 0,193 4 x 240 RM/120 70, ,0754 / 0,153 7 x 1,5 RE/2,5 17, ,1 / 7,41 7 x 2,5 RE/2,5 18, ,41 / 7,41 8 x 1,5 RM/2,5 19, ,5 / 7,41 8 x 2,5 RM/4 20, ,41 / 4,61 10 x 1,5 RM/2,5 21, ,1 / 7,41 10 x 2,5 RM/4 23, ,41 / 4,61 POWER AND CONTROL CABLES 74
75 Number and cross-sectional area of conductor overall diameter net weight of cables Maximum conductor resistance at 20 o C n x mm 2 mm 12 x 1,5 RM/2,5 22, ,1 / 7,41 12 x 2,5 RM/4 24, ,41 / 4,61 14 x 1,5 RM/2,5 23, ,1 / 7,41 16 x 1,5 RM/4 24, ,1 / 4,61 19 x 1,5 RM/4 25, ,1 / 4,61 21 x 1,5 RM/6 26, ,1 / 3,08 21 x 2,5 RM/10 29, ,41 / 1,83 24 x 1,5 RM/6 29, ,1 / 3,08 24 x 2,5 RM/10 32, ,41 / 1,83 30 x 1,5 RM/6 31, ,1 / 3,08 30 x 2,5 RM/10 34, ,41 / 1,83 TYPE: FLAME-X 950, (N)HXH FE180/E 90 0,6/1 kv NORM: DIN VDE 0266, DIN CONSTRUCTION: Conductor: Insulation: Inner covering: Sheath: Colour of sheath: bare copper conductor, circular solid class 1 (RE) or stranded circular or circular compacted class 2 (RM) acc. to EN thermoplastic halogen- free compound type HM4 acc. to HD 604 S1 orange DIN VDE , HD 308 S2 1-core black green-yellow 2-core blue, brown 3-core brown, black, grey green-yellow, blue, brown 3 core* blue, brown, black 4-core blue, brown, black, grey green-yellow, brown, black, grey 4-core* green-yellow, blue, brown, black 5-core blue, brown, black, grey, black green-yellow, blue, brown, black, grey more 5-core * For certain application only. black with numbering green-yellow, others cores black with numbering Maximum conductor operating temperature: +90 o C -30 o C Lowest installation temperature: -5 o C Maximum short-circuit conductor temperature: +250 o C Minimum bending radius: Maximum permissible tensile stress with cable grip for Cu-conductor: 50 N/mm 2 DIN VDE (800 o C, 180 min.), IEC DIN VDE (90 min.) Flame retardant: DIN VDE C, IEC Category A Smoke density: DIN VDE , IEC : light transmittance values > 70% Gases evolved during combustion: VDE , IEC : ph 2,5 S/mm The product is conformed with the RoHS Direktive 2002/95/CE, Low-Voltage Direktive 73/23/EEC and 93/68/ECC Application: Fire resistant security cables for installation everywhere where high safety requirements hotels, underground railway systems, hospitals etc. Standard length cable packing: 500 m on drums. Other forms of packing and delivery are available on request. POWER AND CONTROL CABLES 75
76 Number and cross-sectional area of conductor overall diameter net weight of cables n x mm 2 mm 1 x 1,5RE 7, ,1 1 x 2,5RE 7,7 84 7,41 1 x 4RE 8, ,61 1 x 6RE 8, ,08 1 x 10RE 9, ,83 1 x 16RMC 10, ,15 1 x 25RMC 12, ,727 1 x 35RMC 13, ,524 1 x 50RMC 15, ,387 1 x 70RMC 17, ,268 1 x 95RMC 19, ,193 1 x 120RMC 21, ,153 1 x 150RMC 23, ,124 1 x 185RMC 25, , x 240RMC 29, , x 300RMC 31, , x 1,5RE 14, ,1 2 x 2,5RE 14, ,41 2 x 4RE 15, ,61 2 x 6RE 16, ,08 2 x 10RE 18, ,83 2 x 16RMC 21, ,15 2 x 25RMC 24, ,727 3 x 1,5RE 14, ,1 3 x 2,5RE 15, ,41 3 x 4RE 16, ,61 3 x 6RE 17, ,08 3 x 10RE 19, ,83 3 x 16RMC 22, ,15 3 x 25RMC 25, ,727 3 x 35RMC 28, ,524 3 x 50RMC 32, ,387 3 x 70RMC 36, ,268 3 x 95RMC 41, ,193 3 x 120RMC 45, ,153 3 x 150RMC 50, ,124 3 x 185RMC 55, , x 240RMC 62, , x 1,5RE 16, ,1 4 x 2,5RE 16, ,41 4 x 4RE 18, ,61 4 x 6RE 19, ,08 4 x 10RE 21, ,83 4 x 16RMC 24, ,15 4 x 25RMC 28, ,727 4 x 35RMC 31, ,524 4 x 50RMC 36, ,387 4 x 70RMC 39, ,268 4 x 95RMC 46, ,193 4 x 120RMC 50, ,153 4 x 150RMC 56, ,124 4 x 185RMC 61, , x 240RMC 69, , x 1,5RE 17, ,1 5 x 2,5RE 18, ,41 5 x 4RE 19, ,61 5 x 6RE 20, ,08 5 x 10RE 23, ,83 5 x 16RMC 26, ,15 5 x 25RMC 31, ,727 5 x 35RMC 34, ,524 5 x 50RMC 40, ,387 5 x 70RMC 44, ,268 Maximum conductor resistance at 20 o C POWER AND CONTROL CABLES 76
77 Number and cross-sectional area of conductor overall diameter net weight of cables n x mm 2 mm 5 x 95RMC 51, ,193 5 x 120RMC 55, ,153 5 x 150RMC 62, ,124 5 x 185RMC 68, , x 240RMC 77, , x 1,5RE 18, ,1 7 x 2,5RE 19, ,41 7 x 4RM 22, ,61 8 x 1,5RM 20, ,1 10 x 1,5RM 24, ,1 10 x 2,5RM 25, ,41 12 x 1,5RM 24, ,1 12 x 2,5RM 26, ,41 14 x 1,5RM 26, ,1 14 x 2,5RM 27, ,41 19 x 1,5RM 28, ,1 19 x 2,5RM 31, ,41 24 x 1,5RM 34, ,1 24 x 2,5RM 36, ,41 30 x 1,5RM 36, ,1 Maximum conductor resistance at 20 o C 30 x 2,5RM 39, ,41 3 x 25RMC+16RMC 27, ,727 / 1,15 3 x 35RMC+16RMC 29, ,524 / 1,15 3 x 50RMC+25RMC 34, ,387 / 0,727 3 x 70RMC+35RMC 37, ,268 / 0,524 3 x 95RMC+50RMC 44, ,193 / 0,387 3 x 120RMC+70RMC 47, ,153 / 0,268 3 x 150RMC+70RMC 51, ,124 / 0,268 3 x 185RMC+95RMC 57, ,0991 / 0,193 3 x 240RMC+120RMC 64, ,0754 / 0,153 4 x 50RMC+25RMC 38, ,387 / 0,727 4 x 70RMC+35RMC 42, ,268 / 0,524 4 x 95RMC+50RMC 49, ,193 / 0,387 4 x 120RMC+70RMC 53, ,153 / 0,268 4 x 150RMC+70RMC 58, ,124 / 0,268 TYPE: FLAME-X 950, (N)HXCH FE180/E 90 0,6/1 kv NORM: DIN VDE 0266, DIN CONSTRUCTION: Conductor: Insulation: bare copper conductor, circular solid class 1 (RE) or stranded circular or circular compacted class 2 (RM) acc. to EN Inner covering: Concentric conductor: Separator: Sheath: Colour of sheath: inner layer - round copper wires, outer layer - copper tape tape thermoplastic halogen- free compound type HM4 acc. to HD 604 S1 orange DIN VDE , HD 308 S2 2-core blue, brown 3-core brown, black, grey 3 core* blue, brown, black 4-core blue, brown, black, grey more 7-core black with numbering * For certain application only. POWER AND CONTROL CABLES 77
78 Maximum conductor operating temperature: +90 o C -30 o C Lowest installation temperature: -5 o C Maximum short-circuit conductor temperature: +250 o C Minimum bending radius: Maximum permissible tensile stress with cable grip for Cu-conductor: 50 N/mm 2 DIN VDE (800 o C, 180 min.), IEC DIN VDE (90 min.) Flame retardant: DIN VDE C, IEC Category A Smoke density: DIN VDE , IEC : light transmittance values > 70% Gases evolved during combustion: DIN EN (VDE ), IEC : ph 2,5 S/mm The product is conformed with the RoHS Direktive 2002/95/CE, Low-Voltage Direktive 73/23/EEC and 93/68/ECC Application: Fire resistant security cables for installation everywhere where high safety requirements hotels, underground railway systems, hospitals etc. Standard length cable packing: 500 m on drums. Other forms of packing and delivery are available on request. Number and cross-sectional area of conductor overall diameter net weight of cables Maximum conductor resistance at 20 o C n x mm 2 mm 2 x 1,5 RE/1,5 15, ,1 / 12,1 2 x 2,5 RE/2,5 16, ,41 / 7,41 2x4RE/4 17, ,61 / 4,61 2x6RE/6 18, ,08 / 3,08 2 x 10 RE/10 20, ,83 / 1,83 2 x 16 RM/16 23, ,15 / 1,15 2 x 25 RM/16 26, ,727 / 1,15 2 x 35 RM/16 28, ,524 / 1,15 3 x 1,5 RE/1,5 16, ,1 / 12,1 3 x 2,5 RE/2,5 17, ,41 / 7,41 3x4RE/4 18, ,61 / 4,61 3x6RE/6 19, ,08 / 3,08 3 x 10 RE/10 21, ,83 / 1,83 3 x 16 RM/16 24, ,15 / 1,15 3 x 25 RM/16 28, ,727 / 1,15 3 x 35 RM/16 30, ,524 / 1,15 3 x 50 RM/25 35, ,387 / 0,727 3 x 70 RM/35 39, ,268 / 0,524 3 x 95 RM/50 45, ,193 / 0,387 3 x 120 RM/70 49, ,153 / 0,268 3 x 150 RM/70 54, ,124 / 0,268 3 x 185 RM/95 59, ,0991 / 0,193 4 x 1,5 RE/1,5 17, ,1 / 12,1 4 x 2,5 RE/2,5 18, ,41 / 7,41 4x4RE/4 20, ,61 / 4,61 4x6RE/6 21, ,08 / 3,08 4 x 10 RE/10 23, ,83 / 1,83 4 x 16 RM/16 26, ,15 / 1,15 4 x 25 RM/16 30, ,727 / 1,15 4 x 35 RM/16 33, ,524 / 1,15 4 x 50 RM/25 39, ,387 / 0,727 4 x 70 RM/35 43, ,268 / 0,524 4 x 95 RM/50 49, ,193 / 0,268 4 x 120 RM/70 54, ,153 / 0,268 4 x 150 RM/70 60, ,124 / 0,268 4 x 185 RM/95 65, ,0991 / 0,193 4 x 240 RM/120 74, ,754 / 0,153 7 x 1,5 RE/2,5 20, ,1 / 7,41 7 x 2,5 RE/2,5 21, ,41 / 7,41 7x4RE/4 24, ,61 / 4,61 10 x 1,5 RM/2,5 25, ,1 / 7,41 10 x 2,5 RM/4 27, ,41 / 4,61 POWER AND CONTROL CABLES 78
79 Number and cross-sectional area of conductor overall diameter net weight of cables Maximum conductor resistance at 20 o C n x mm 2 mm 12 x 1,5 RM/2,5 26, ,1 / 7,41 12 x 2,5 RM/4 28, ,41 / 4,61 16 x 2,5 RM/6 31, ,41 / 3,08 19 x 1,5 RM/4 30, ,1 / 4,61 19 x 2,5 RM/6 33, ,41 / 3,08 21 x 1,5 RM/6 32, ,1 / 3,08 21 x 2,5 RM/10 35, ,41 / 1,83 24 x 1,5 RM/6 36, ,1 / 3,08 24 x 2,5 RM/10 39, ,41 / 1,83 POWER AND CONTROL CABLES 79
80 80
81 CHAPTER VII MEDIUM AND HIGH VOLTAGE POWER CABLES 81
82 MEDIUM VOLTAGE XLPE INSULATED POWER CABLES AHXAMK-W, TSLE, AXCEL, AHXCMK-WTC, MV_HV_EHVP TYPE: AHXAMK-W 6/10/(12) kv Completely Watertight Power Cable NORM: SFS 5636, HD 620 5F, IEC CONSTRUCTION: 1. - Round, stranded and compacted watertight aluminium conductor 2. - Three cores are stranded around the centre copper conductor 3. - Semi-conductive XLPE 4. - XLPE compound 5. - Semi-conductive XLPE and water swellable semi-conductive tape 6. - Aluminium foil bonded tightly to sheath providing radial waterightness 7. - Black weather resistant PE Application: - Laying in ground - Laying in air Highest permissible conductor temperature: Lowest recommended temperature during laying: - Continous operation 90 C - Short circuit (duration max 5 s) 250 C -20 C DESCRIPTION UNIT DETAILS CONSTRUCTION DATA 3x x x x Conductor Nominal cross sectional area sqmm Conductor diameter and tolerance mm , , , , , , ,4 Minimum thickness semi-conducting XLPE on conductor mm Insulation thickness: minimum average XLPE mm Insulation thickness: minimum at a point mm Diameter over insulation mm Metalling screen Aluminium foil bonded tightly to sheath providing radial watertightness Oversheath thickness nominal PE mm overall diameter - completed cable (De) mm Centre conductor Round, stranded and compacted copper conductor Weight of complete cable (Approx.) kg/km DELIVERY DATA Diameter of wooden drum mm type K20 K22 K22 K24 K24 K24 K24 Maximum length per drum m Weight of heaviest reel, including cable kg ELECTRICAL DATA Maximum D.C. resistance of phase conductor at 20 C A.C. resistance of phase conductor at 90 C Induction reactance Capacitance reactance MEDIUM AND HIGH VOLTAGE POWER CABLES 82
83 MECHANICAL DATA Recommended min. bending radius for laying - phase m cable m Recommended permissible - phase m cable m SHORT CIRCUIT CURRENTS Maximum permissible thermal short-circuit Current for 1 sec. (IEC 949) ka AMPACITY in earth A in air A Current rating guideline (Calculated according to IEC Publ. 287 and the following conditions) Ground temperature max. 20 C Ambient air temperature max. 25 C Laying depth 0.70m Ground thermal resistivity 1.0 K m/w TYPE: AHXAMK-W 12/20/(24) kv Completely Watertight Power Cable NORM: SFS 5636, HD 620 5F, IEC CONSTRUCTION: 1. Round, stranded and compacted watertight aluminium conductor 2. Three cores are stranded around the centre copper conductor 3. Semi-conductive XLPE 4. XLPE compound 5. Semi-conductive XLPE and water swellable semi-conductive tape 6. Aluminium foil bonded tightly to sheath providing radial waterightness 7. Black weather resistant PE Application: - Laying in ground - Laying in air Highest permissible conductor temperature: Lowest recommended temperature during laying: - Continous operation 90 C - Short circuit (duration max 5 s) 250 C -20 C DESCRIPTION UNIT DETAILS CONSTRUCTION DATA 3x x x x Conductor Nominal cross sectional area sqmm Conductor diameter and tolerance mm , , , , , , ,4 Minimum thickness semi-conducting XLPE on conductor mm Insulation thickness: minimum average XLPE mm Insulation thickness: minimum at a point mm Diameter over insulation mm Metalling screen Aluminium foil bonded tightly to sheath providing radial watertightness Oversheath thickness nominal PE mm overall diameter - completed cable (De) mm Centre conductor Round, stranded and compacted copper conductor Weight of complete cable (Approx.) kg/km MEDIUM AND HIGH VOLTAGE POWER CABLES 83
84 DELIVERY DATA Diameter of wooden drum mm type K24 K24 K24 K24 K24 K24 K24 Maximum length per drum m Weight of heaviest reel, including cable kg ELECTRICAL DATA Maximum D.C. resistance of phase conductor at 20 C A.C. resistance of phase conductor at 90 C Induction reactance Capacitance reactance MECHANICAL DATA Recommended min. bending radius for laying - phase m cable m Recommended permissible bending - phase m cable m SHORT CIRCUIT CURRENTS Maximum permissible thermal short-circuit Current for 1 sec. (IEC 949) ka AMPACITY in earth A in air A Current rating guideline (Calculated according to IEC Publ. 287 and the following conditions) Ground temperature max. 20 C Ambient air temperature max. 25 C Laying depth 0.70m Ground thermal resistivity 1.0 K m/w TYPE: TSLE 6/10 kv * Completely Watertight Power Cable NORM: SFS 5636, HD 620 5F, IEC CONSTRUCTION: 1. Round, stranded and compacted aluminium conductor. Class B. Longitudinally watertight 2. Extruded semi-conducting conductor screen 3. Insulation XLPE - Dry cured 4. Extruded semi-conducting insulation screen fully bonded 5. Semi-conducting swelling tape 6. Metallic screen: copper wires helix and copper counter helix tape 7. Semi-conducting swelling tape 8. Laminated aluminium foil 9. Sheath: MDPE Application: Highest permissible conductor temperature: Lowest recommended temperature during laying: * We offer also: 7/12 kv, 14/24 kv - Laying in ground - Laying in ducts - Laying in air - Continous operation 90 C - Overload 130 C - Short circuit (duration max 5 s) 250 C -20 C MEDIUM AND HIGH VOLTAGE POWER CABLES 84
85 DESCRIPTION UNIT DETAILS CONSTRUCTION DATA 1x50/16 1x70/16 1x95/25 1x120/25 1x150/25 1x185/35 1x240/35 1x300/35 1x400/35 1x500/35 1x630/35 1x800/35 Conductor - mataerial Aluminium Aluminium Aluminium Aluminium Aluminium Aluminium Aluminium Aluminium Aluminium Aluminium Aluminium Aluminium Nominal cross sectional mm area Conductor diameter and tolerance Minimum thickness semiconducting XLPE on mm 8,5 +0,10 9,5 +0,20 11,3 +0,20 12,5 +0,20 14,7 +0,20 15,8 +0,20 17,8 +0,10 20,3 +0,40 22,9 +0,30 25,7 +0,40 29,3 +0,40 33,0 +0,50 mm 0,3 0,3 0,3 0,3 0,3 0,3 0,3 0,3 0,3 0,3 0,3 0,5 conductor Insulation thickness: minimum average XLPE mm 3,40 3,40 3,40 3,40 3,40 3,40 3,40 3,40 3,40 3,40 3,40 3,40 Insulation thickness: minimum at a point mm 2,96 2,96 2,96 2,96 2,96 2,96 2,96 2,96 2,96 2,96 2,96 2,96 Diameter over insulation -nominal mm 16,6 17,7 19,5 20,7 22,9 24,0 25,9 29,0 31,5 34,4 38,4 42,6 Metallic screen Copper Wires No x mm 22x0,95 22x0,95 36x0,95 36x0,95 36x0,95 50x0,95 50x0,95 50x0,95 50x0,95 50x0,95 50x0,95 50x0,95 Copper counter helix tape Noxmm 1x10x0,10 1x10x0,10 1x10x0,10 1x10x0,10 1x10x0,10 1x10x0,10 1x10x0,10 1x10x0,10 1x10x0,10 1x10x0,10 1x10x0,10 1x10x0,10 Thickness of semiconductive swelling tape mm ~ 0,5 ~ 0,5 ~ 0,5 ~ 0,5 ~ 0,5 ~ 0,5 ~ 0,5 ~ 0,5 ~ 0,5 ~ 0,5 ~ 0,5 ~ 0,5 Thickness of aluminium foil mm 0,25 0,25 0,25 0,25 0,25 0,25 0,25 0,25 0,25 0,25 0,25 0,25 mm 1,7 1,7 1,8 1,8 1,9 1,9 2,0 2,1 2,2 2,3 2,4 2,5 Nominal outer sheath thickness overall diameter completed cable (De) Weight of complete cable (Approx.) Diameter of wooden drum mm 25,7 26,8 28,8 30,0 32,4 33,5 35,6 39,1 41,8 44,9 49,5 53,9 kg/km DELIVERY DATE m 1,6 1,6 1,6 1,8 1,8 1,8 1,8 2,0 2,2 2,2 2,2 2,2 - type 16A 16A 16A B 22M 22A 22M 22M Maximum length per drum Weight of heaviest reel, including cable Maximum D.C. conductor resistance at 20 C m kg ELECTRICAL DATA 0,6410 0,4430 0,3200 0,2530 0,2060 0,1640 0,1250 0,1000 0,0778 0,0605 0,0469 0,0367 Maximum A.C. conductor resistance at 90 C 0,8250 0,5690 0,4150 0,3250 0,2650 0,2150 0,2650 0,1300 0,1050 0,8000 0,0650 0,0550 Operating inductance - trefoil formation mh/km 0,422 0,398 0,378 0,366 0,347 0,340 0,329 0,318 0,308 0,299 0,293 0,286 MEDIUM AND HIGH VOLTAGE POWER CABLES 85
86 - at formation (*) mh/km 0,607 0,583 0,563 0,551 0,532 0,525 0,514 0,503 0,493 0,484 0,477 0,470 Induction reactance - trefoil formation 0,133 0,125 0,119 0,115 0,109 0,107 0,104 0,100 0,097 0,094 0,092 0,090 0,191 0,183 0,177 0,173 0,167 0,165 0,162 0,158 0,155 0,152 0,150 0,148 Mutual capacitance µf/km 0,236 0,257 0,291 0,314 0,355 0,376 0,411 0,467 0,514 0,567 0,642 0,720 Capacitance reactance 13,50 12,40 10,95 10,20 9,00 8,45 7,75 6,85 6,20 5,65 4,95 4,45 MECHANICAL DATA Recommended min. bending radius for laying m 0,64 0,67 0,72 0,75 0,81 0,84 0,89 0,98 1,04 1,12 1,24 1,35 Recommended permissible bending Maximum permissible pulling force with a pulling: Maximum permissible thermal short-circuit Current for 1 sec. (IEC949) Phase conductor m 0,52 0,54 0,58 0,60 0,65 0,68 0,72 0,80 0,84 0,90 1,00 1,08 kn 1,5 2,1 2,85 3,6 4,5 5,55 7,2 9, ,9 24 SHORT CIRCUIT CURRENTS ka 4,9 6,8 9,2 11,6 14,5 17,8 23,1 28,8 38,3 47,9 60,2 76,4 AMPACITY in earth - trefoil formation A A in air - trefoil formation A A Current rating guideline (Calculated according to IEC Publ. 287 and the following conditions) Ground temperature 20 C Ambient air temperature 30 C Load factor 0.7 Ground thermal resistivity 1.0 K m/w Laying depth 0.7 MEDIUM AND HIGH VOLTAGE POWER CABLES 86
87 TYPE: AXCEL 7/12 kv ** Longitudinally Watertight Power Cable NORM: SS , IEC CONSTRUCTION: 1. Round, stranded and compacted aluminium. Conductor class B. Longitudinally watertight 2. Extruded semi-conducting conductor screen 3. Insulation XLPE - dry cured 4. Extruded semi-conducting insulation screen 5. Separate screen ( semi-cobnductive band for each conductor ) 7. Separator 8. Sheath: black PE Application: - Laying in ground - Laying in air Highest permissible conductor temperature: Lowest recommended temperature during laying: - Continous operation 90 C - Short circuit (duration max 5 s) 250 C -20 C DESCRIPTION UNIT DETAILS CONSTRUCTION DATA Conductor Aliuminium Nominal cross sectional area Conductor diameter and tolerance m , , , ,1 Minimum thickness semi-conducting XLPE on conductor mm Insulation thickness: minimum average XLPE mm Insulation thickness: minimum at a point mm Diameter over insulation mm Minimum thickness semi-conducting XLPE on insulation mm Thickness semi-conductove tape mm Diameter over stranded cable core mm Thickness semi-conductove tape mm Metalling screen Copper Wires No x mm 22 x x x x 0.95 Noxmmxmm 1 x 10 x x 10 x x 10 x x 10 x 0.10 Thickness of separate tape mm Oversheath thickness minimum at a point mm Oversheath thickness nominal PE mm overall diameter completed cable (De) mm Weight of complete cable (Approx.) kg/km DELIVERY DATA Diameter of wooden drum m type K18 K20 K24 K24 Maximum length per drum m Weight of heaviest reel, including cable kg MEDIUM AND HIGH VOLTAGE POWER CABLES 87
88 ELECTRICAL DATA Maximum D.C. conductor resistance at 20 C A.C. conductor resistance at 90 C Maximum D.C. screen resistance at 20 C A.C. screen resistance at 80 C Operating inductance mh/km Induction reactance Mutual capacitance µf/km Capacitance reactance MECHANICAL DATA Recommended min. bending radius for laying m m Maximum permissible pulling force with a pulling: kn SHORT CIRCUIT CURRENTS Maximum permissible thermal short-circuit Current for 1 sec. (IEC 949) ka ka AMPACITY in earth A in air A Ground temperature 20 C Ambient air temperature 25 C Load factor 0.7 Ground thermal resistivity 1.0 K m/w TYPE: AHXCMK-WTC 6/10/(12) kv NORM: HD620-5F CONSTRUCTION: 2. Extruded semi-conducting conductor screen 3. Insulation XLPE 4. Extruded semi-conducting insulation screen, fully bonded 5. Semi-conducting tape 6. Metallic screen of copper wires and copper counter tape 7. Polyester tape 8. Outer sheath of black PVC Application Laying in ground Laying in air Highest permissible conductor temperature Continuous operation 90 C Overload 130 C Short circuit 250 C(duration max 5 s) Laying is possible without any special measures at natural cable temperatures not lower than -5 C AHXCMK-WTC DESCRIPTION UNIT DETAILS CONSTRUCTION DATA AHXCMK-WTC Conductor -material - alluminium alluminium -number of wires No Nominal cross sectional area sqmm Conductor diameter mm Minimum thickness of semi-conducting XLPE on conductor mm Insulation thickness: minimum average mm Insulation thickness: minimum at a point mm MEDIUM AND HIGH VOLTAGE POWER CABLES 88
89 AHXCMK-WTC AHXCMK-WTC DESCRIPTION UNIT DETAILS diameter over insulation mm Nominal thickness of semi-conducting tape mm Metallic screen - nominal cross sectional area sqmm copper wires No x mm 36 x x 0.95 Noxmmxmm 1x10x0.1 1x10x0.1 Nominal thickness of polyester tape mm Nominal thickness of outer sheath mm overall diameter of complete cable mm weight of complete cable kg/km DELIVERY DATA m x m 2.2 x x type 22A 22A Maximum length per drum m weight of heaviest reel, including cable kg MECHANICAL DATA Recommended min. bending radius for laying mm Maximum permissible pulling force with a pulling eye on conductor kn ELECTRICAL DATA Maximum D.C. conductor resistance at 20ºC Maximum A.C. conductor resistance at 90ºC SHORT CIRCUIT CURRENTS Maximum permissible thermal short-circuit current for 1 sec. ka ka in earth - trefoil formation A in duct - trefoil formation A in air - trefoil formation A TYPE: AHXCMK-WTC 12/20/(24) kv NORM: HD620-5F CONSTRUCTION: 2. Extruded semi-conducting conductor screen 3. Insulation XLPE 4. Extruded semi-conducting insulation screen, fully bonded 5. Semi-conducting tape 6. Metallic screen of copper wires and copper counter tape 7. Polyester tape 8. Outer sheath of black PVC Application Laying in ground Laying in air Highest permissible conductor temperature Continuous operation 90 C Overload 130 C Short circuit 250 C(duration max 5 s) Laying is possible without any special measures at natural cable temperatures not lower than -5 C MEDIUM AND HIGH VOLTAGE POWER CABLES 89
90 AHXCMK-WTC AHXCMK-WTC AHXCMK-WTC AHXCMK-WTC DESCRIPTION UNIT DETAILS CONSTRUCTION DATA Conductor -material - alluminium alluminium alluminium alluminium -number of wires No Nominal cross sectional area sqmm Conductor diameter mm Minimum thickness of semi-conducting XLPE on mm conductor Insulation thickness: minimum average mm Insulation thickness: minimum at a point mm diameter over insulation mm Nominal thickness of semi-conducting tape mm Metallic screen - nominal cross sectional area sqmm copper wires No x mm 22 x x x x 0.95 No x mm x mm 1 x 10 x x 10 x x 10 x x 10 x 0.1 Nominal thickness of polyester tape mm Nominal thickness of outer sheath mm overall diameter of complete cable mm weight of complete cable kg/km DELIVERY DATA m x m 2 x x x x type Maximum length per drum m weight of heaviest reel, including cable kg MECHANICAL DATA Recommended min. bending radius for laying mm Maximum permissible pulling force with a pulling eye on conductor kn ELECTRICAL DATA Maximum D.C. conductor resistance at 20ºC Maximum A.C. conductor resistance at 90ºC SHORT CIRCUIT CURRENTS Maximum permissible thermal short-circuit current for 1 sec. ka ka in earth - trefoil formation A in duct -trefoil formation A in air - trefoil formation A Ground temperature 20 C Ambient air temperature 30 C Laying depth 0.7 m Ground thermal resistivity 1 K m/w MEDIUM AND HIGH VOLTAGE POWER CABLES 90
91 TYPE: HXCMK-WTC 6/10/(12) kv NORM: HD620-5F CONSTRUCTION: 2. Extruded semi-conducting conductor screen 3. Insulation XLPE 4. Extruded semi-conducting insulation screen, fully bonded 5. Semi-conducting tape 6. Metallic screen of copper wires and copper counter tape 7. Polyester tape 8. Outer sheath of black PVC Application Laying in ground Laying in air Highest permissible conductor temperature Continuous operation 90 C Overload 130 C Short circuit 250 C(duration max 5 s) Laying is possible without any special measures at natural cable temperatures not lower than -5 C HXCMK-WTC HXCMK-WTC HXCMK-WTC DESCRIPTION UNIT DETAILS CONSTRUCTION DATA Conductor - material - copper copper copper - number of wires No Nominal cross sectional area sqmm Conductor diameter mm Minimum thickness of semi-conducting XLPE on conductor mm Insulation thickness: minimum average mm Insulation thickness: minimum at a point mm diameter over insulation mm Nominal thickness of semi-conducting tape mm Metallic screen - nominal cross sectional area sqmm copper wires No x mm 22 x x x 0.95 No x mm x mm 1 x 10 x x 10 x x 10 x 0.1 Nominal thickness of polyester tape mm Nominal thickness of outer sheath mm overall diameter of complete cable mm weight of complete cable kg/km DELIVERY DATA m x m 1.6 x x x 1.7 -type Maximum length per drum m weight of heaviest reel, including cable kg MECHANICAL DATA Recommended min. bending radius for laying mm Maximum permissible pulling force with a pulling eye on conductor kn ELECTRICAL DATA Maximum D.C. conductor resistance at 20ºC Maximum A.C. conductor resistance at 90ºC MEDIUM AND HIGH VOLTAGE POWER CABLES 91
92 SHORT CIRCUIT CURRENTS Maximum permissible thermal short-circuit current for 1 sec. ka ka in earth - trefoil formation A in duct - trefoil formation A in air - trefoil formation A Ground temperature 20 C Ambient air temperature 30 C Laying depth 0.7 m Ground thermal resistivity 1 K m/w TYPE: HXCMK-WTC 12/20/(24) kv NORM: HD620-5F CONSTRUCTION: 2. Extruded semi-conducting conductor screen 3. Insulation XLPE 4. Extruded semi-conducting insulation screen, fully bonded 5. Semi-conducting tape 6. Metallic screen of copper wires and copper counter tape 7. Polyester tape 8. Outer sheath of black PVC Application Laying in ground Laying in air Highest permissible conductor temperature Continuous operation 90 C Overload 130 C Short circuit 250 C(duration max 5 s) Laying is possible without any special measures at natural cable temperatures not lower than -5 C HXCMK-WTC HXCMK-WTC DESCRIPTION UNIT DETAILS CONSTRUCTION DATA Conductor - material - copper copper - number of wires No 7 36 Nominal cross sectional area sqmm Conductor diameter mm Minimum thickness of semi-conducting XLPE on conductor mm Insulation thickness: minimum average mm Insulation thickness: minimum at a point mm diameter over insulation mm Nominal thickness of semi-conducting tape mm Metallic screen - nominal cross sectional area sqmm copper wires No x mm 22 x x 0.95 Noxmmxmm 1x10x0.1 1x10x0.1 Nominal thickness of polyester tape mm Nominal thickness of outer sheath mm overall diameter of complete cable mm weight of complete cable kg/km MEDIUM AND HIGH VOLTAGE POWER CABLES 92
93 DELIVERY DATA m x m 2 x x type Maximum length per drum m weight of heaviest reel, including cable kg MECHANICAL DATA Recommended min. bending radius for laying mm Maximum permissible pulling force with a pulling eye on conductor kn ELECTRICAL DATA Maximum D.C. conductor resistance at 20ºC Maximum A.C. conductor resistance at 90ºC SHORT CIRCUIT CURRENTS Maximum permissible thermal short-circuit current for 1 sec. ka ka in earth - trefoil formation A in duct - trefoil formation A in air - trefoil formation A Ground temperature 20 C Ambient air temperature 30 C Laying depth 0.7 m Ground thermal resistivity 1 K m/w TYPE: AHXCMK-WTC 6/10/(12) kv NORM: HD-620 6F CONSTRUCTION: 1. Round, stranded and compacted WTC aluminium conductor. Class Extruded semi-conducting conductor screen 3. Insulation XLPE, dry cured 4. Extruded semi-conducting insulation screen, fully bonded 5.Semiconducting tape 6. Assembly of cores 7. Semi-conducting tape 8. Metallic screen of copper wires and counter copper tape 9. Polyester tape 10. Outer sheath of black PE Application Laying in ground Laying in air Highest permissible conductor temperature Continuous operation 90 C Overload 130 C Short circuit 250 C(duration max 5 s) Laying is possible without any special measures at natural cable temperatures not lower than -20 C MEDIUM AND HIGH VOLTAGE POWER CABLES 93
94 AHXCMK-WTC AHXCMK-WTC DESCRIPTION UNIT DETAILS CONSTRUCTION DATA Conductor - material - aluminium aluminium - number of wires No Nominal cross sectional area sqmm Conductor diameter mm Minimum thickness of semi-conducting XLPE on conductor mm Insulation thickness: minimum average mm Insulation thickness: minimum at a point mm diameter over insulation mm Nominal thickness of semi-conducting tape mm Metallic screen - nominal cross sectional area sqmm copper wires No x mm 36 x x 0.95 Noxmmxmm 1x10x0.1 1x10x0.1 Nominal thickness of polyester tape mm Nominal thickness of outer sheath mm overall diameter of complete cable mm weight of complete cable kg/km DELIVERY DATA m x m 2.8 x x type 28 A 24 A Maximum length per drum m weight of heaviest reel, including cable kg MECHANICAL DATA Recommended min. bending radius for laying mm Maximum permissible pulling force with a pulling eye on conductor kn ELECTRICAL DATA Maximum D.C. conductor resistance at 20ºC Maximum A.C. conductor resistance at 90ºC SHORT CIRCUIT CURRENTS Maximum permissible thermal short-circuit current for 1 sec. ka ka in earth - trefoil formation A in duct - trefoil formation A in air - trefoil formation A Ground temperature 20 C Ambient air temperature 25 C Laying depth 0.7 m Ground thermal resistivity 1 K m/w MEDIUM AND HIGH VOLTAGE POWER CABLES 94
95 TYPE: AHXCMK-WTC 12/20/(24) kv NORM: HD-620 6F CONSTRUCTION: 1. Round, stranded and compacted WTC aluminium conductor. Class Extruded semi-conducting conductor screen 3. Insulation XLPE, dry cured 4. Extruded semi-conducting insulation screen, fully bonded 5.Semiconducting tape 6. Assembly of cores 7. Semi-conducting tape 8. Metallic screen of copper wires and counter copper tape 9. Polyester tape 10. Outer sheath of black PE Application Laying in ground Laying in air Highest permissible conductor temperature Continuous operation 90 C Overload 130 C Short circuit 250 C(duration max 5 s) Laying is possible without any special measures at natural cable temperatures not lower than -20 C AHXCMK-WTC AHXCMK-WTC AHXCMK-WTC AHXCMK-WTC DESCRIPTION UNIT DETAILS CONSTRUCTION DATA Conductor -material - aluminium aluminium aluminium aluminium -number of wires No Nominal cross sectional area sqmm Conductor diameter mm Minimum thickness of semi-conducting XLPE on mm conductor Insulation thickness: minimum average mm Insulation thickness: minimum at a point mm diameter over insulation mm Nominal thickness of semi-conducting tape mm Metallic screen - nominal cross sectional area sqmm copper wires No x mm 42 x x x x 0.95 No x mm x mm 1 x 10 x x 10 x x x 10 x 0.1 Nominal thickness of polyester tape mm Nominal thickness of outer sheath mm overall diameter of complete cable mm weight of complete cable kg/km DELIVERY DATA m x m 2.8 x x x x type Maximum length per drum m weight of heaviest reel, including cable kg MECHANICAL DATA Recommended min. bending radius for laying mm Maximum permissible pulling force with a pulling eye on conductor kn MEDIUM AND HIGH VOLTAGE POWER CABLES 95
96 ELECTRICAL DATA Maximum D.C. conductor resistance at 20ºC Maximum A.C. conductor resistance at 90ºC SHORT CIRCUIT CURRENTS Maximum permissible thermal short-circuit current for 1 sec. ka ka in earth - trefoil formation A in duct - trefoil formation A in air - trefoil formation A Ground temperature 20 C Ambient air temperature 25 C Laying depth 0.7 m Ground thermal resistivity 1 K m/w MEDIUM AND HIGH VOLTAGE POWER CABLES 96
97 MV, HV, EHV POWER CABLES type: N2XSY, N2XS2Y, NA2XSY, NA2XS2Y * we offer also single core cables in triplex formation type: N2XS(F)2Y, NA2XS(F)2Y * we offer also single core cables in triplex formation type: N2XS(FL)2Y, NA2XS(FL)2Y * we offer also single core cables in triplex formation type: N2XSEY, NA2XSEY, N2XSE2Y, NA2XSE2Y Power cables with copper or aluminium conductors, extruded XLPE insulation, longitudinally and radial type: XRUH(A)KXS, N(A)2XS(FL)2Y, TSLE, AXLJ-TT, Cu/XLPE/CWS/LT/PE MEDIUM AND HIGH VOLTAGE POWER CABLES 97
98 MEDIUM AND HIGH VOLTAGE POWER CABLES 98
99 CHAPTER VIII SPECIAL CABLES 99
100 XLPE-COVERED OVERHEAD CONDUCTORS PAS TYPE: PAS-W 6/10 kv Medium voltage covered overhead conductor NORM: Adapted to SFS 5790 CONSTRUCTION: Conductor: Insulation: Round stranded aluminium alloy conductor water blocking system XLPE (cross-linked polyethylene) References standards: IEC Aluminium - magnesium - silicon alloy wire for overhead line conductor IEC Aluminium stranded conductor IEC Calculation of the continuous current rating of cables IEC Extruded solid dielectric insulated power cables voltages from 1 kv to 30 kv 1kVto30kV SFS Electrical and mechanical design of PAS - line Medium voltage covered overhead conductor and accesories (such as: Insulation Piercing Conector, Arcing protection device, Dead - end Clamp, Suspension Pulley Clamp) were tested in ENSTO SEKKO Laboratory. All tests complies with the requirements in the standard SFS No. Parameter Nominal cross-section [mm 2 ] Conductor material AlMgSi Alloy 2. Insulation material Flame retardant XLPE 3. Insulation thickness[mm] 2,0 4. Cable outer dia. [mm] 10,9 12,5 13,9 15,3 16,8 18,3 22,2 5. Cable conductor dia. [mm] 6,9 8,5 9,9 11,3 12,8 14,2 18,1 6. Cable weight [kg/km] Breaking load [kn] 10,3 14,2 20,6 28,2 35,2 43,0 71,0 8. Permissible normal tensile stress [MPa] Permissible reduced tensile stress [MPa] Permissible normal critical stress [MPa] Permissible reduced critical stress [MPa] x ,9 14,9 14,9 15,2 15,2 15,4 15, ,6 15,6 15,6 15,9 15, ,1 15. Recommended min. cable loading [kn] 0,7 1,0 1,4 1,9 2,4 2,7 3,1 16. Creep resistance for 25 % R m loading [mm/m] 0,5 17. Continuous rating at ambient temp (A) SPECIAL CABLES 100
101 TYPE: PAS-W 12/20 kv Medium voltage covered overhead conductor NORM: SFS 5790 CONSTRUCTION: Conductor: Insulation: Round stranded aluminium alloy conductor water blocking system XLPE (cross-linked polyethylene) References standards: IEC Aluminium - magnesium - silicon alloy wire for overhead line conductor IEC Aluminium stranded conductor IEC Calculation of the continuous current rating of cables IEC Extruded solid dielectric insulated power cables voltages from 1 kv to 30 kv 1kVto30kV SFS Electrical and mechanical design of PAS - line Medium voltage covered overhead conductor and accesories (such as: Insulation Piercing Conector, Arcing protection device, Dead - end Clamp, Suspension Pulley Clamp) were tested in ENSTO SEKKO Laboratory. All tests complies with the requirements in the standard SFS No. Parameter Nominal cross-section [mm 2 ] Conductor material AlMgSi Alloy 2. Insulation material Flame retardant XLPE 3. Insulation thickness[mm] 2,3 4. Cable outer dia. [mm] 11,5 13,1 14,5 15,9 17,4 18,9 22,8 5. Cable conductor dia. [mm] 6,9 8,5 9,9 11,3 12,8 14,2 18,1 6. Cable weight [kg/km] Breaking load [kn] 10,2 14,6 20,7 28,2 35,9 43,0 71,0 8. Permissible normal tensile stress [MPa] Permissible reduced tensile stress [MPa] Permissible normal critical stress [MPa] Permissible reduced critical stress [MPa] x ,9 14,9 14,9 15,2 15,2 15,4 15, ,6 15,6 15,6 15,9 15, ,1 15. Recommended min. cable loading [kn] 0,7 1,0 1,4 1,9 2,4 2,7 3,1 16. Creep resistance for 25 % R m loading [mm/m] 0,5 17. Continuous rating at ambient temp (A) SPECIAL CABLES 101
102 AERIAL BUNDLED CONDUCTORS EX, AMKA TYPE: EX 0,6/1 kv Self-supporting, bundle assembled, aerial cables with aluminium conductors and polyethylene insulation for overhead power lines NORM: NEN CONSTRUCTION: Conductor: phase, neutral conductors are made as stranded, compacted conductors with 7 or 19 aluminium wires Insulation: is made with sun radiation resistant thermoplastic polyethylene and is applied by extrusion method Aluminium wires properties Insulation properties - phase cores: Longitudinal, embossed ribs on insulation in amount 1, 2, 3, visible with the naked eye and checked by touch - neutral core: Embedded print, giving type of cable, cross-section area of phase and neutral conductors, manufacturer name, production year, nominal voltage (0.6/1 kv) or thread under insulation identifying of manufacturer- kind of marking subject to agreement with customer Parameter Unit Value Resistivity at 20 0 C max Elongation at break % min. 1.3 Tensile strength MPa min / 0 C 23x10-6 1/ 0 C 4.03x10-3 Parameter Unit Value Permissible long-lasting operation temperature of cable 0 C 70 Tensile strength before and after ageing MPa min Elongation at break before ageing % min. 350 Elongation at break after ageing kv min. 300 Resistance of insulation for testing voltage after 24h immersion in water kv 4 Minimum permissible ambient temperature during cable installation 0 C -20 Parameters of cores Nominal cross-sectional area of conductor mm Nominal diameter of conductor mm Nominal diameter over insulation mm Permissible continuous current ratings A Calculated minimum tensile strength kn Conductor dc resistance at 20 0 C /MPa 18.2 x 10-6 SPECIAL CABLES 102
103 Parameters of bundle assembled cables Number of cores & cross-section area diameter of bundle weight n x mm 2 mm kn 2x16 14, ,8 2x25 17, ,0 2x35 19, ,6 2x50 22, ,3 2x95 29, ,8 3x16 15, ,1 3x25 18, ,1 3x35 21, ,0 3x50 24, ,5 3x95 32, ,3 4x16 17, ,5 4x25 20, ,1 4x35 23, ,3 4x50 27, ,6 4x95 36, ,7 Calculated minimum tensile strength of bundle TYPE: AMKA 0,6/1 kv Low overhead voltage cable NORM: SFS 2200 CONSTRUCTION: Conductor: Supporting conductor: Insulation: 16 mm2: Round and solid aluminium conductor mm2: Round stranded aluminium conductor Round stranded aluminium alloy conductor Black PE Highest permissible conductor temperature: References standards: - continuous operation 70 0 C - short circuit ( up to 1s) C Phase conductors: 2, 3, or 4 longitudinal ridges SFS Self-supporting overhead cable AMKA IEC Aluminium - magnesium - silicon alloy wire for overhead line conductors conductor IEC Aluminium stranded conductor IEC Calculation of the continuous current rating of cables IEC Extruded solid dielectric insulated power cables voltages from 1 kv to 30 kv HD 626 S1/A2 - Overhead distribution cables of rated voltage Uo/U/Um: 0,6/1/1,2 kv No. Parameter of phase conductor Nominal cross-section [mm2] Conductor bare diameter (min). [mm] 4,4 5,9 7,0 8,2 9,6 13,0 2. Insulation thickness [mm] 1,4 1,4 1,6 1,6 1,8 2,0 3. Resistance max (at 20 0 /km] 1,91 1,20 0,868 0,641 0,443 0, Resistance max (at 70 0 /km] 2,29 1,44 1,04 0,770 0,532 0, Tensile strength [N/mm2] 120 SPECIAL CABLES 103
104 Parameter of supporting conductor Nominal cross-section [mm2] Supporting conductor material AlMgSi Alloy 7. Conductor diameter (min). [mm] 6,1 7,0 8,2 9,9 11,5 8. Resistance max (at 20 0 C, DC)) 1, ,720 0,493 0, Calculated strength of conductor [kn] ,3 14,2 20,6 27,9 10. Tensile strength [N/mm2] Parameter of cable Size of cable [no of cores x mm2] 1x x x x x x x Cable weight [kg/km] Outer diameter [mm] current carring capacity [A] Modulus of elasticity [N/mm2] ,0x Cable weight [kg/km] ??? 17 Outer diametrer [mm] ??? SPECIAL CABLES 104
105 ENAMELLED COPPER WIRES H 180, CX 200, C 200 TYPE: ENAMELLED COPPER WIRE H 180 NORM: IEC , DIN EN , NEMA MW 30-C, MW 74-C, UL approval File No E CONSTRUCTION: Production range Insulation: Features Applications Grade 1-0,03 2,00 mm Grade 2-0,03 2,00 mm Temperature index of 180, good resistance to heat shock and thermal overloads Used for the motors for household appliances, hermetic motors, transformers Overall diameter max 1,094 Mechanical properties Flexibility 10% 1 d Pencil hardness 4/5 H Elongation Temperature index >180 Thermal properties Cut through Heat shock at 200 C 1xd Electrical properties Breakdown voltage > 1,5 IEC Tangent delta /TD 300/ >180 Resistance to standard solvents good Chemical properties Resistance to refrigerants good Resistance to transformer oils good TYPE: ENAMELLED COPPER WIRE CX 200 NORM: IEC , DIN EN , NEMA MW 35C CONSTRUCTION: Production range Insulation: Grade 1-0,15 2,00 mm Grade 2-0,15 2,00 mm Features High temperature index of 200, good resistance to high temperture overload, excellent mechanical and chemical characteristics Applications Used in motors, transformers, ballasts, and hermetic motors, coils designed for class H, windings produced on high speed automatic machines SPECIAL CABLES 105
106 Mechanical properties Thermal properties Electrical properties Chemical properties Overall diameter max 1,094 Flexibility 10% 1 d Pencil hardness 6 H Elongation Temperature index >200 Cut through Heat shock at 220 C 1xd Breakdown voltage > 1,5 IEC Tangent delta /TD 300/ Resistance to standard solvents very good Resistance to transformer oils very good Resistance to refrigerants very good TYPE: ENAMELLED COPPER WIRE C 200 NORM: IEC , DIN EN , NEMA MW 35C, UL approval File No E CONSTRUCTION: Production range Insulation: Features Applications Grade 1-0,71 4,00 mm Grade 2-0,71 4,00 mm Very high thermal properties and high adhesion to copper, excellent mechanical and chemical characteristics Used in motors, transformers, windings for the automotive industry and severe winding conditions Overall diameter max 1,094 Mechanical properties Flexibility 10% 1 d Pencil hardness 6 H Elongation Temperature index >200 Thermal properties Cut through Heat shock at 220 C 1xd Electrical properties Breakdown voltage > 1,5 IEC Tangent delta /TD 300/ Chemical properties Resistance to standard solvents very good Resistance to transformer oils very good SPECIAL CABLES 106
107 CHAPTER IX TELECOMUNICATION CABLES 107
108 TELECOMMUNICATION LOCAL UNIT CABLES PE INSULATED AND SHEATHED VMOHBU TYPE: VMOHBU TELECOMMUNICATION CABLE CONSTRUCTION: Description: 1. Insulated wires twisted into pairs 2. Polyester tape 3. Aluminium tape 4. PE outer sheath Colours - of conductors insulation pair a wire b wire 1 white blue 2 white orange 3 white green white brown 5 white grey 6 black blue 7 black orange black green black brown 10 black grey - of outer sheath: black Cable Cable weight Cable diameter Sheath thickness [mm] [mm] 3x2x0,5 73,2 8,8 1,8 5x2x0,5 96,3 10,0 1,8 10x2x0,5 145,4 12,3 1,8 20x2x0,5 236,2 15,5 1,8 30x2x0,5 322,5 18,0 1,8 50x2x0,5 491,3 22,0 1,8 100x2x0,5 905,9 29,8 2,0 200x2x0,5 1686,2 40,3 2,2 400x2x0,5 3192,7 55,2 2,4 5x2x0,6 117,4 11,1 1,8 10x2x0,6 185,4 13,7 1,8 20x2x0,6 307,0 17,5 1,8 30x2x0,6 423,3 20,4 1,8 50x2x0,6 660,4 25,2 1,8 100x2x0,6 1223,1 34,1 2,0 10x2x0,8 268,5 16,3 1,8 20x2x0,8 467,6 21,1 1,8 30x2x0,8 658,0 24,8 1,8 50x2x0,8 1059,2 31,3 2,0 100x2x0,8 2047,1 44,6 2,2 TELECOMUNICATION CABLES 108
109 TELECOMMUNICATION LOCAL CABLES PAIRED MHS TYPE: MHS TELECOMMUNICATION CABLE CONSTRUCTION: Description: 1. Insulated wires, twisted into pairs (quad for 1x4x0,5) 2. Drain wire 3. Polyester tape 4. Al./Pet tape 5. Rip-cord 6. Control wire 7. PVC outer sheath Colours - of insulation quad second pair wire a wire b wire c wire d 1 blue white orange white pair wire a wire b 1 blue white 2 orange white 3 green white 4 brown white 5 grey white 6 blue black 7 orange black 8 green black 9 brown black 10 grey black - of control wire: red - of outer sheath: black Cable Cable weight Cable diameter Sheath thickness [mm] [mm] 1x4x0,5 32,77 5,1 0,8 3x2x0,5 39,91 5,6 0,8 5x2x0,5 52,77 6,4 0,8 10x2x0,5 81,83 7,9 0,8 20x2x0,5 136,21 10,1 0,8 30x2x0,5 193,26 12,0 0,9 50x2x0,5 295,36 14,7 0,9 100x2x0,5 550,03 19,9 1,0 TELECOMUNICATION CABLES 109
110 TELECOMMUNICATION INDOOR CABLES MANUFACTURED ACC. TO INTER- NATIONAL STANDARDS KLM, KLMA TYPE: KLM TELECOMMUNICATION CABLE CONSTRUCTION: Description: 1. Insulated conductors 2. Polyester tape 3. PVC sheath Colours - of insulation Number of wire Colour 1 blue 2 yellow 3 white 4 red - of outer sheath: grey Cable Sheath thickness Cable weight Cable diameter [mm] nominal [mm] approx. 2x0,8 0,5 26,7 4,6 4x0,8 0,6 46,7 6,0 TYPE: KLMA TELECOMMUNICATION CABLE CONSTRUCTION: Description: 1. Insulated conductors 2. Drain wire 3. Polyester tape 4. Al/Pet type 5. PVC sheath Colours - of insulation Number of wire Colour 1 blue 2 yellow 3 white 4 red - of outer sheath: grey Cable Sheath thickness Cable weight Cable diameter [mm] nominal [mm] approx. 2x0,8+0,8 0,5 33,5 5,0 4x0,8+0,8 0,6 54,1 6,3 TELECOMUNICATION CABLES 110
111 ADDITIONAL INFORMATION WE PRODUSE ALSO
112 1. SINGLE CORE NON-SHEATHED CABLES RUBBER, HEAT RESISTING SINGLE CORE NON-SHEATHED CABLES H05G-U; H05G-K; H07G-U; H07G-R; H07G-K 2.FIXED INSTALLATION CABLES UNSCREENED FIXED INSTALLATION CABLES YDY; YLY; EKK, FKK; FR-N05VV-U; FR-N05VV-R; PFXP; VMvK; PVC-insulated and PVC-sheathed cables with circuit protective conductor; PVC-insulated and PVC-sheathed cables SCREENED LOW SMOKE HALOGEN FREE FIXED INSTALLATION CABLES HALOGEN-FREE LOW SMOKE FIRE RESISTANT FIXED INSTALLATION CABLES 3. PVC SHEATHED FLEXIBLE CORDS H03V2V2-F; H03V2V2H2-F; H05V2V2-F; H05V2V2H2-F 4.HALOGEN-FREE THERMOPLASTIC INSULATED AND SHEATHED FLEXIBLE CORDS H03Z1Z1-F; H03Z1Z1H2-F; H05Z1Z1-F; H05Z1Z1H2-F 5.CABLES IN RUBBER 6.HEAT RESISTING SILICONE CABLES RUBBER, HEAT RESISTING SINGLE CORE NON-SHEATHED CABLES SID; H05S-U; H05S-K RUBBER, HEAT RESISTING SHEATHED CABLES H05SS-F 7.PUR - SHEATHED CABLES H05BQ-F; 05BQ-F; H07BQ-F; 07BQ-F; NYMH11YO 8.POWER AND CONTROL LV PVC INSULATED POWER AND CONTROL CABLES NAYY; NYK; NYKY; NFYw;YKY;1-CYKY; CBT; YAKY; 1-YAKY, CABT, LV XLPE INSULATED POWER AND CONTROL CABLES LV POWER CABLES WITH CONCENTRIC COPPER CONDUCTOR NAYCY; NYCWY; NAYCWY; PFSP; TFSP; EKKJFKKJ; AKKJ;Single-phase split concentric cables; Single-phase helical concentric LV ARMOURED POWER CABLES ARMOURED HALOGEN-FREE LOW SMOKE POWER CABLES 9.MEDIUM and HIGH VOLTAGE POWER CABLES MEDIUM VOLTAGE XLPE INSULATED POWER CABLES 112
113 SABS MEDIUM VOLTAGE POWER CABLES MEDIUM VOLTAGE PAPER INSULATED POWER CABLES NKBA; NKBY; NAKBA; NAKBY; NKRA; NAKRA; NKFA; NAKFA; NKFY; NAKFY; NKRY; NAKRY; NHKBA; NAHKBA; NHKY; NAHKY 10.CONTROL AND INSTRUMENTATION CABLES FLEXIBLE CONTROL CABLES INSTRUMENTATION CABLES Polyethylene insulated instrumentation cables Type 1 and Type 2; PVC insulated instrumentation cables Type 1 and Type 2 11.SHIPBOARD CABLES XLPE INSULATED POWER SHIPBOARD CABLES YKOXS; YKOXSek; YKOXSuy HALOGEN FREE LOW SMOKE POWER SHIPBOARD CABLES HALOGEN-FREE LOW SMOKE FIRE RESISTANT POWER SHIPBOARD CABLES XLPE INSULATED TELECOMMUNICATION SHIPBOARD CABLES YTKOXSekw HALOGEN-FREE LOW SMOKE TELECOMMUNICATION SHIPBOARD CABLES NTKOXSekw HALOGEN-FREE LOW SMOKE FIRE RESISTANT TELECOMMUNICATION SHIPBOARD CABLES 12.CABLES ACCORDING TO UL STANDARDS SPT-1, SPT-2, SPT-3; SJTW, SJT; ST, STW; SO, SOW; SO; SEOOW; SJ, SJO, SJOW; SJOW BREATHER CABLE; SOOW; Type S.C Stage 13. SPECIAL CABLES ENAMELLED COPPER WIRES VEHICLE CABLES IGNITION CABLES FZLY; FZL2G; FZL2GF2G; FZL2G2G; FZLW2GF2G; FZLW2G2G COAXIAL CABLES SPEAKER CABLES Speaker cables HEATING CABLES MINING CABLES PVC-COVERED OVERHEAD CONDUCTORS 113
114 covered aluminium conductors, steel reinforced Type 16 PLAIN AND TINNED COPPER WIRES PLAIN AND TINNED COPPER CONDUCTORS Flexible copper bunched conductors, plain or tinned; Round and shaped copper conductors for power cables COPPER TROLLEY WIRES BARE CONDUCTORS FOR OVERHEAD POWER TRANSMISSION Copper stranded conductors; AAC; AAAC; ACSR WINDING WIRES 14.TELECOMUNICATION CABLES TELECOMMUNICATION LOCAL UNIT CABLES PE INSULATED AND SHEATHED XzTKMXw; XzTKMXpw; XzTKMXwFtlx; XzTKMXwFtly; XzTKMXpwFtlx; XzTKMXpwFtly; XzTKMXwFfx; XzTKMXpwFfx; XzTKMXwAlfFfx; TELECOMMUNICATION INDOOR CABLES MANUFACTURED ACC. TO INTERNATIONAL STANDARDS TELECOMMUNICATION LOCAL CABLES PAIRED XTKMXw; XTKMXpw; XzTKMXw; XzTKMXpw; XzTKMXwn; XzTKMXpwn; XzTKMXwn; XzTKMXpwn; TKMXn; NTKMXFtlN; TKSY; YTKSY; TELECOMMUNICATION INDOOR CABLES MANUFACTURED ACC. TO INTERNATIONAL STANDARDS TELECOMMUNICATIONS LOW FREQUENCY INDOOR CABLES YTKSYekw; YnTKSYekw; YTKSYlekw TELECOMMUNICATIONS LOW FREQUENCY INDOOR CABLES, SCREENED PAIRS YTKSYekp TELECOMMUNICATIONS LOW FREQUENCY INDOOR CABLES UP TO 2 Mbit/s YTKSXpekp; YnTKSXpekp; YTKSXpekp; YTKSXekp; YnTKSXekp; YnTKSXpekp; Y-YTKSXekp; Yn-YTKSXekp; Y-YTKSXpekp; Yn- YTKSXpekp; YTKSXpekteko;NTKSXpekteko TELECOMMUNICATIONS LOW FREQUENCY INDOOR CABLES IN FLAME RETARDANT INSULATION NTKSXekw; NzTKX; YnTKSXekw DATA TELECOMMUNICATIONS LOW FREQUENCY TERMINATING CABLES YTKZYekw BUILDING CORDS TDY; TDX TELECOMMUNICATION BUILDING CORDS FOR WRAPPED CONNECTIONS TDYo TELECOMMUNICATION BUILDING CORDS Y; J-FY BROADCASTING CORDS RPX; YRPX; YnRPX 15.DATA COMMUNICATION CABLES UTP Cat. 5, 5e; UTP DUAL Cat. 5, 5e; FTP, S-FTP Cat. 5, 5e; STP, S-STP Cat. 5, 5e; UTP FLEX Cat. 5, 5e; FTP FLEX Cat. 5, 5e; UTP OUT DOOR, UTPf OUT DOOR Cat. 5; FTP OUT DOOR, FTPf OUT DOOR, FTPn OUT DOOR, FTPnf OUT DOOR Cat OPTICAL FIBRE CABLES OPTICAL FIBRE OUTDOOR CABLE OF LOOSE TUBE CONSTRUCTION Z-XOTKtsd; Z-XzOTKs; Z-XOTKtsdD; Z-XXOTKtsdD; Z-XzOTKtsD; Z-XXzOTKtsD; Z-XOTKtcdD; Z-XOTKtcd; ZW-NOTKtcdD; ZW- OPTICAL FIBRE MINING CABLES YOTKGtsFoyn; NOTKGtsFoN; YOTKGtsFfyn; NOTKGtsFfN; YOTKGtsDFoyn; NOTKGtsDFoN; YOTKGtsDFfyn; NOTKGtsDFfN 114
115 OPTICAL FIBRE OUTDOOR, SELF-SUPPORTING CABLE OF LOOSE TUBE CONSTRUCTION ADSS-XXOTKtsdD; ADSS; S-XOTKtsd; S-XOTKtsdD; S-XzOTKts; S-XzOTKtsD OPTICAL FIBRE INDOOR CABLES OF LOOSE TUBE CONSTRUCTION OPTICAL FIBRE INDOOR-OUTDOOR CABLES OF LOOSE TUBE CONSTRUCTION OPTICAL FIBRE INDOOR ASSEMBLE CABLES W-NOTKSd; W-YOTKSd OPTICAL FIBRE INDOOR BREAKOUT CABLES W-NNOTKSd; W-YYOTKSd OPTICAL FIBRE CABLES FOR MILITARY PSKD OPTICAL FIBRE CABLES CERTIFICATED VDE OPTICAL FIBRE CABLES CERTIFICATED UKRSEPRO (Ukraine) OPTICAL FIBRE CABLES VDE CERTIFICATED UKRSEPRO (Ukraine) W-YOTKS; W-YnOTKS; W-NOTKS 115
116 Spausdino UAB Judex, Europos pr. 122, LT Kaunas
VIPERFLEX ELECTRIC CABLE
VIPERFLEX Flexible Low Voltage Electric Cable - 0.6/1kV (Rubber insulated) H07 RN-F & H07 BN-F Single Core 2-Core 2-Core and Earth 3-Core and Earth 4-Core and Earth Multi-Core and Earth H07 RCN-F & H07
FLEXIBLE INDUSTRIAL CABLES H07RN-F TENAFLEX SR
FLEXIBLE INDUSTRIAL CABLES H07RN-F TENAFLEX SR Standards : CENELEC HD 22.4 NF C 32-102-4 DIN VDE 0282-1 and VDE 0282-4 BS 6007 and BS 6500 IEC 60245-4 Rated voltage Rated voltage: 450/750 V (Use up to
www.ptranscable.com We specialize in low voltage cables including: Stranded Single Cable H07V-R Flexible Single Cable H05V-K
P-trans, meaning power transistor, is a well known cable manufacturer based in Aan - Jordan. The production plant produces all sorts of high quality low tension cables and is a leader in the industry supplying
Power and Wiring Cables
1 Single-Core PVC 1X...................... 1: Single-Core PVC/PVC 1Y.................. 1: Flat Twin & Flat Three Core PVC /Y........ 1: Multicore XLPE/LSF/SWA/LSF BS Control Cable.............................
CONFLEX ELECTRIC CABLE
CONFLEX ELECTRIC CABLE CONFLEX - 0.6/1kV Flexible VSD/EMC Cables Applications WW VSD/EMC cables are manufactured for use where electrical interference distorts signal transmission in electric motors. Standard
Chemical resistance Accidental
Industrial flexible cable, insulation and outer sheath in elastomer Description Application TITANEX flexible cable is intended for installations with moving equipment, electric appliances and for building
The Quality Connection. BETAflam Fire Resistant Safety Cables
The Quality Connection BETAflam Fire Resistant Safety Cables 2 Contact Consulting and sales Switzerland Phone +41 (0)62 288 82 82 Fax +41 (0)62 288 83 83 [email protected] www.leoni-infrastructure-datacom.com
Of wires & cables having nominal voltage up to 1000 V and heat resistant wire & cables, ambient temperature 30 C. Cable or lead category
Table 12-1: Power rating : Power Rating Basic Table ÖLFLEX Of wires & cables having nominal voltage up to 1000 V and heat resistant wire & cables, ambient temperature 30 C Method of installation A Single
Flexible Control Cables
Works photo: KUKA Flexible Control Cables A Flexible Control Cables Since generations people try to build machines and plants which shall take on different functions. To raise, sink, slide, drill, transport
Global cable expertise for rolling stock
Global cable expertise for rolling stock Global cable expertise for rolling stock Single and multicore Low voltage control cables Jumper cables HV roof cables (25 kv) rubber cables for power needs of locomotives
Allweather and Rubber Cables
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 21 Owings Mills, MD 211 USA web: http://mdmetric.com ph: ()353130 (00)3130 fx: ()3532 (00)729329 email: [email protected] RFQ form: http://mdmetric.com/rfq.htm
Fire Resistant Cables
109/4 Fire Resistant Cables SR 114H Standard - SR 114E Enhanced BS 5839-1 BS 7629-1 BS 6387 BS 8434-1/2 BS 6425 BS 7622 EN 50200 World-wide recognized high quality cables Firecel SR114 are used in: Data
Festoon 715 P PUR cable for flexible application in festoon systems
CABLES FOR CRANE AND CONVEYOR APPLICATIONS Festoon 715 P PUR cable for flexible application in festoon systems S AB BRÖCKSKES D-VIERSEN Festoon 715 P 1 x 16.0 mm 2 C Marking for Festoon 715 P 07150162:
ENERGY. TECWATER S1BN8-F 0,6/1 kv. Cable for Water Application
ENERGY TECWATER S1BN8-F 0,6/1 kv Cable for Water Application Technical Data Electrical parameters Thermal parameters Trademark Type designation Specification Approval Application Rated voltage Maximum
with coloured cores and overall copper screen UL/CSA... 17
CONTENT Cable Track Cables y SD 200 extremely flexible TPE/PUR data cable with coloured cores for continuous movement..... 6 y S 200 extremely flexible TPE/PUR control cable with numbered cores for continuous
BETAtrans. Cables and Systems for Rolling Stock. Edition 2006
BETAtrans Cables and Systems for Rolling Stock. Edition 2006 Info Consulting and Sales By Phone To ask for Information or to place an order please use the following number: +49 (0)9172-6844-11 By Fax For
BRÖCKSKES D-VIERSEN PV1-F 4,0 mm BRÖCKSKES D-VIERSEN PV1-F 4,0 mm d d 2 2 C VDE-REG.-Nr. 8292 10/2009
d BRÖCKSKES BRÖCKSKES D-VIERSEN D-VIERSEN PV1-F PV1-F 4,0 mm 4,0 2 mm VDE-REG.-Nr. 2 C 8292 10/2009 s - THE COMPANY DIN EN ISO 9001 More than 60 years of experience in temperature measurement and control
INTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 60502-1 Second edition 2004-04 Power cables with extruded insulation and their accessories for rated voltages from 1 kv (U m = 1,2 kv) up to 30 kv (U m = 36 kv) Part 1: Cables
Flexible cables for submersible products
Flexible cables for submersible products Standards SUBCAB cables complies with the following general standards: IEC 6045 (general) IEC 608 class 5 (conductor) IEC 608-- CLAUSE 9 (oil resistant) IEC 608--
PROFIBUS cable. for PROFIBUS-PA and -DP 10/63-6.46 EN
for PROFIBUS-PA and -DP 10/63-6.46 EN CPN 080/CPE 080-Ex PROFIBUS-PA basis cable AWG 18, 0.88 mm 2 Use For fixed installation indoor and outdoor, on racks and in conduits. Application Fieldbus cable for
Flygt flexible cables
Flygt flexible cables Contents Standards General SUBCAB 4 Screened SUBCAB 6 Rubber cable type: NSSHÖU-J 7 Screened rubber cable type: NSSHÖU../E + ST 8 FGB screened rubber cable 9 PUR control cable 0 HCR
RADOX railway cables acc. to EN 50264 and EN 50306. Edition 2009
RADO railway cables acc. to EN 50264 and EN 50306 Edition 2009 Bridging our know how Interdisciplinary knowledge The HUBER+SUHNER Group is a leading international manufacturer of electrical and optical
Building Cables and Wires
Building Cables and Wires 4 Introduction alfanar is equipped with state-of-the-art manufacturing facilities such as latest machineries, instrumentation, quality control and testing laboratory, etc., for
Fire retardant IEC 60332-1
300 / 500 V Description Approval Certificates VDE Reg N 7691 Application In dry and moist rooms for light mechanical stresses. Outdoors only when protected. Not in water. As supply and interconnecting
VDE-approved PVC-Control Cables
Works photo: HELUKAEL VDE-approved PVC-Control Cables VDE-approved PVC-Control Cables This certification/licency is issued according to the rules of the HAR Agreement, wherein the certification/ licency
PROFIBUS cable. PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications
Data Sheet 10/63-6.47-EN Rev. D PROFIBUS cable PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications PROFIBUS PA cables Non-Ex (Hazardous) applications Ex (Hazardous) applications
Cable flexibility Flexible. Chemical resistance Accidental
H07RN-F Industrial flexible cable, insulation and outer sheath in elastomer Description pplication H07RN-F flexible cable is intended for installations with moving equipment, electric appliances and for
DATA SHEET SERVO LK SMS FX8PLUS SIGNAL
Application LAPP servo cables according to Siemens * (see footnote) Standard FX8008 PLUS SIGNAL are a new generation of very highly flexible screened signal (encoder and resolver)- cables (P/Ns 00277101
ENERGY. TECSUN DUO (PV) Twin Cables for Photovoltaics
ENERGY TECSUN DUO (PV) Twin Cables for Photovoltaics Auswahlkriterien Manufacturer Trademark Approvals Application Prysmian Kabel und Systeme GmbH Kabel- und Leitungswerk Neustadt bei Coburg / Germany
International Electrotechnical Commission Standards
International Electrotechnical Commission Standards Standard IEC 60028 IEC 60038 IEC 60050-461 IEC 60055-1 IEC 60055-2 IEC 60092-101 IEC 60092-350 IEC 60092-351 IEC 60092-352 IEC 60092-353 IEC 60092-354
FIRE RESISTANT CABLE CONSTRUCTION OF CABLES
FIRE RESISTANT CABLE In all fire disasters, fire smoke, heat and toxic fumes are the main obstacles to safe evacuation of a building or area. A major contribution towards overcoming these hazards is the
UGVCL/SP/591/11KV HT AB CABLE
TECHNICAL SPECIFICATION FOR 11KV AERIAL BUNCHED CABLES FOR OVERHEAD LINES (CROSSED LINKED POLYTHENE DRY GAS CURED) 1. SCOPE This specification covers requirements of XLPE insulated, 11 KV Aerial Bunched
Airdac CNE and SNE, 600/1000V, Polyethylene Sheath, SANS 1507, NRS 063 & NRS 017
Airdac CNE and SNE, 600/1000V, Polyethylene Sheath, SANS 1507, NRS 063 & NRS 017 Conductor: Hard Drawn Copper Conductor Class 2 Insulation: LV-XLPE Phase Color Code(SNE): Red, Black & Bare Copper Phase
Gulf Cable & Electrical Ind. Co.
CONTENTS INTRODUCTION PRODUCT RANGE I PRODUCT DATA TABLES Irrigation 1 Coaxial s for T.V/ Satellite Antenna etc 2 Data Transmission s - 4 pair 24 AWG 3 TELEPHONE CABLES Telephone cables CCP-LAP & CCP-LAP-SS
Gulf Cable & Electrical Ind. Co.
CONTENTS INTRODUCTION PRODUCT RANGE I PRODUCT DATA TABLES XLPE INSULATED 600/1000V CABLES Two Core Cables CU/XLPE/PVC/LC/PVC/SWA/PVC 1 Three Core Cables CU/XLPE/PVC/LC/PVC/SWA/PVC 2 Four Core Cables CU/XLPE/PVC/LC/PVC/SWA/PVC
THE WAY FOR ENERGY HALOGEN FREE, LOW SMOKE AND FIRE RESISTANT CABLES
THE WAY FOR ENERGY HALOGEN FREE, LOW SMOKE AND FIRE RESISTANT CABLES Table of Contents FIRE SAFETY 002 TELE-FONIKA Kable 004 PRODUCTION POTENTIAL 006 LEADING STANDARDS, TESTING AND REGULATIONS 008 FIRE
FIRE RESISTANT CABLES FP200 GOLD
FIRE RESISTANT CABLES FP200 GOLD FIRE RESISTANT CABLES FP200 GOLD BS7629-1:2008 Certificate No 077f Certificate No 077k FP200 GOLD The original highly durable and dressable, easy to terminate and install
AFUMEX LSX LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 BASEC APPROVED PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:
PRODUCT DATASHEET & APPLICATIONS GUIDE BASEC APPROVED AFUMEX LSX LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 KEY BENEFITS: BASEC approved for the full size range of BS8436 (1.0mm 2 to 2.5mm 2
Flexible Cables and Cords
PVC Types Tri-Rated Single-Core....................... : H0V-K (1X) & H0V-K (01X) Single-Core... : DEF 1-1 Equipment Wires.................. : PVC Insulated and Sheathed Flexible Multicore (1*Y).........................
RELIABLE AND EFFICIENT MINING MINING CABLES
RELIABLE AND EFFICIENT MINING MINING CABLES 2 TABLE OF CONTENTS MINING CABLES 2 TELE-FONIKA KABLE 3 PRODUCTION POTENTIAL 5 VDE STANDARDS AND (HD) HARMONIZED STANDARDS OPEN PIT MINES R- (N)TSCGE WÖU 3.6/6
MEDIUM VOLTAGE CABLES Up to and including 36 KV
MEDIUM VOLTAGE CABLES Up to and including 6 KV NOTICE As this catalogue is not intendedto cover all of LIBAN CABLES SAL possibilities in special cables manufacturing, the hereafter listing of the types
LEAD FREE FIREX. Interlock Armored Cables TECK90 and MC Industrial Cables. w w w. n e x a n s e n e r g y. c o m
FIREX Interlock Armored Cables TECK90 and MC Industrial Cables LEAD FREE O V E R 1 8 0 Y E A R S O F E X P E R I E N C E 866-663-9267 w w w. n e x a n s e n e r g y. c o m Interlock Armored Cables Introduction....2
< SD 200 C TP Continuously flexible TPE/PUR paired data cable with coloured cores and overall copper screen... 10
CONTENT General < The Company..................................................................................... 3 Customized cables for different applications < Data / POF Cables POF-LWL and hybrid
MV CABLE TYPE C 33-226
MV CABLE TYPE C 33-226 Standards : CENELEC HD 620 C 33-226 Rated voltage Rated voltage : 12/20 (24) kv Design 1 Stranded aluminium, class 2 conductor 2 Extruded conducting screen on conductor 3 XLPE insulation
The Quality Connection. BETAflam Safety cables for highest demands
The Quality Connection BETAflam Safety cables for highest demands 2 For solutions that will still be standard tomorrow. BETAflam Safety cables Thanks to their proven quality, BETAflam safety cables are
FOREWORD ONE OF THE WORLD S BIGGEST COMPANIES IN THE SECTOR.
OFFSHORE CABLES FOREWORD ONE OF THE WORLD S BIGGEST COMPANIES IN THE SECTOR. General Cable Corporation is one of the world s leading cable manufacturing companies. In its work it has contributed decisively
Communication, Signal & Data Cables
Communication, Signal & Data Cables Used for indoor installation and interconnection of transmission, telephone, telegraph and electronic equipment as well as media equipments www.alfanar.com Communication
THE PATHWAY TO POWER HIGH-VOLTAGE CABLES
THE PATHWAY TO POWER HIGH-VOLTAGE CABLES TABLE OF CONTENTS HIGH-VOLTAGE CABLES 3 Advantages of XLPE-insulated cable systems 3 PROPOSAL 4 Cable systems 4 Providing System Solutions 4 Continuous temperature
Photo: HELUKABEL. Cables according to International Approvals N 1
Photo: HELUKABEL Cables according to International Approvals N 1 Cables according to International Approvals The installation of cables and wires according to overseas standards is getting more and more
CLEVELAND CABLE LOCATIONS
A WORLD POWER IN CABLE SUPPLY THE CABLE AND ACCESSORY CATALOGUE 2011 2 CLEVELAND CABLE LOCATIONS CLEVELAND CABLE LOCATIONS 3 As is illustrated within our catalogue, we stock a comprehensive range of cables
CAVEL VS80205 MADE IN ITALY 1000 V
0,05 9,00 x 7,20 (Pet) (LSZH) Attached CE01 CE02 Sheath Colour black black red Non-migrating Polyester tape longitudinally overlapped (Pet) 25 x 23 µm Outer sheath of Thermoplastic material - black - halogen-free,
4 IX D N E P P A Installation methods Current-carrying capacity and voltage drop for cables Reference method IET Wiring Matters
8 Appendix 4 of BS 7671 by Mark Coles Appendix 4, Current-carrying capacity and voltage drop for cables and flexible cords, has seen significant changes with the publishing of BS 7671:2008. This article
Flexible and safe solutions, for decades. Cables for alarmand safety systems
Flexible and safe solutions, for decades. Cables for alarmand safety systems 2 We offer the widest range of cables on the market for every kind of installation. It s all about reliability. It is always
Specializing in the cable business for over 38 years, PT. SUPREME CABLE
Specializing in the cable business for over 38 years, PT. SUPREME CABLE MANUFACTURING & COMMERCE Tbk. (PT. SUCACO Tbk) has grown steadly to become a largest and leading cable manufacturer, with international
CURRENT RATINGS MORE THAN A CABLE
CURRENT RTINGS Updated for the 17th Edition of the IEE Wiring Regulations MORE THN CBLE C O M P N Y EI CBLES, DURHM ROD, BIRTLEY, CO DURHM. DH3 2R Tel: +44 (0)191 410 3111 Fax: +44 (0)191 410 8312 E-mail:
Quality Reliability Innovation. ISO 9001 : 2000 CERTIFIED BY AFAQ No. QUAL / 1997 / 7034 a COPPER TELECOMMUNICATION CABLES
Quality Reliability Innovation ISO : CERTIFIED BY AFAQ No. QUAL / 7 / 7 a COPPER TELECOMMUNICATION CABLES COPPER TELECOMMUNICATION CABLES CONTENTS 7 NOTICE INTRODUCTION QUALITY ASSURANCE RECOMMENDED ORDERING
T A B L E T 1 T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A
T A B L E T 1 1 of 7 Tests & Inspection Cable PCUT & PCUT-A (Table T1) T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A No. Test Scale MOC Requirements G 20:10:001:01 Defined Test
450-750 VOLTS - Copper conductor PVC insulated SSA 1320, IEC 60227 & BS 6004 HO 7V - U With Solid Conductor - TYPE 60227 IEC 01. Insulation Thickness
450 50 VOLTS Copper conductor PVC insulated SSA 320, IEC 6022 & BS 6004 HO V U With Solid TYPE 6022 IEC 0 For internal wiring equipment rated voltage up to 000 V AC and up to 50 V to earth. Catalogue Number
KNOW YOUR OPTIONS: 230 KV POWER CABLES
KNOW YOUR OPTIONS: 230 KV POWER CABLES 71 CONDUCTOR MATERIAL AND SIZE Conductor material is a matter of both customer preference and required current carrying capacity At 230 kv, copper is most common
Network Standard Advice No. 1420C 9/6/2011
Network Standard Advice No. 1420C 9/6/2011 TO: Customers, Service Providers and Ausgrid Staff. Advisory Note on Changes to the Use of 11kV Cable Types. Introduction This Network Standard Advice (NSA) provides
Temperature Permissible ambient temperature. Weather Resistance to severe weather conditions. Impacts Cable mechanical resistance to impacts
Airfield Cables Issue 10/2003 Piktogramme Temperature Permissible ambient temperature Weather Resistance to severe weather conditions Impacts Cable mechanical resistance to impacts Chemical attacks Resistance
108-93018 05 APR 2016 Rev M
Product Specification 108-93018 05 APR 2016 Rev M Copper LAN Cable 1. SCOPE 1.1. Content This specification describes the general requirements for CommScope copper LAN cable. 2. APPLICABLE DOCUMENTS The
Instrumentation Cable...14-17. Power Cable...2-11. Assembly Solutions...32
Severe Cold Durability Exceeds CSA Cold Bend / Cold Impact (-0 C/-35 C) Drilling Mud Resistant Flame Retardant Certified to IEC 9-3 (33-3A) and IEEE 580 Oil Resistant Assemblies...3-33 Ester Based Mud
COAX Cables Radio Frequency Cables
COAX Cables Radio Frequency Cables Contents Page Table of contents Pictographs General information Introduction Types and abbreviations Temparature range Construction Characteristics Special constructions
Conductix-Wampfler Cables for Reeling Systems
Conductix-Wampfler Cables for Reeling Systems Cables for systems in motion selected from experts Advantage 1 Secure choice of cables Comprehension of our customers applications and needs is the foundation
Series 8146/5-V37 and Series 8150/5-V37
www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection
Tri-Rated Flexible PVC Equipment Wire
Application: High temperature, flame retardant wire designed for use in the switch control, relay and instrumentation panels of power switchgear and for purposes such as internal connectors in rectifier
Section 5 161 kv Power Cables
Know Your Options: 161 kv Power Cable 61 material and size material is a matter of both customer preference and required current carrying capacity Copper conductor common for larger loads When both copper
CABLES FOR PHOTOVOLTAIC SOLAR ENERGY INSTALLATIONS FOR CLEAN ENERGY
CABLES FOR PHOTOVOLTAIC SOLAR ENERGY INSTALLATIONS FOR CLEAN ENERGY One Company Connecting The World POWERFUL PRESENCE PRODUCTS PERFORMANCE PEOPLE General Cable has been a wire and cable innovator for
HINDUSTAN PETROLEUM CORPORATION LIMITED ENGINEERING & PROJECTS GRESHAM ASSURANCE HOUSE, 2 ND FLOOR, A-1595(3) 1-A, SIR P M ROAD, FORT MUMBAI-400 001
NEW POL DEPOT AT HINDUSTAN PETROLEUM CORPORATION LIMITED ENGINEERING & S GRESHAM ASSURANCE HOUSE, 2 ND FLOOR, A-1595(3) 1-A, SIR P M ROAD, FORT MUMBAI-400 001 TECHNICAL SPECIFICATION OF XLPE, FRLS LT CABLES
CABLE SPECIFICATION CAN CAB RJ45-SUBD9
CABLE SPECIFICATION All technical information contained in this document is the exclusive property of STI and may neither be used nor disclosed without its prior written consent. AAV 33801 1/8 Connector
e-mobility Special cables for electric vehicles Coroplast Fritz Müller GmbH & Co. KG Tapes Cables Cable Assemblies
www.echtzeit.com e-mobility Coroplast Fritz Müller GmbH & Co. KG Tapes Cables Cable Assemblies Special cables for electric vehicles Wittener Straße 271 D-42279 Wuppertal Phone +49(0)202.2681.228 Fax +49(0)202.2681.360
TECHNICAL SPECIFICATION FOR LOW-FREQUENCY CABLES AND WIRES WITH PVC INSULATION AND PVC SHEATH
Rev. 1:2007 TECHNICAL SPECIFICATION FOR LOW-FREQUENCY CABLES AND WIRES WITH PVC INSULATION AND PVC SHEATH Suruhanjaya Komunikasi dan Multimedia Malaysia Off Pesiaran Multimedia, 63000 Cyberjaya, Selangor
MEDIUM VOLTAGE POWER CABLES
MEDIUM VOLTAGE POWER CABLES CONTENTS 1 GENERAL INTRODUCTION 4 TECHNICAL INFORMATION 15 25 35 45 Single Core XLPE Insulated PVC Sheathed Cables UNARMOURED CABLES COPPER UNARMOURED CABLES ALUMINUM ALUMINUM
ScottishPower Distribution Cables & Equipment. Metal Theft
ScottishPower Distribution Cables & Equipment Metal Theft April 2012 As an aid to deterring to metal theft this booklet has been put together to help identify the types of utility power cables and associated
KAT0130-0002a-E. Product Overview Cables
KAT0130-0002a-E Product Overview Cables Known brands - provided by experts Advantage 1 Safe choice of cables understanding the needs of our customers applications, we offer the safety of the right cable
100% EMI Emission Containment
100% EMI Emission Containment Designed for Longer Service Life Highly Flexible for Easier Handling and Faster Installation Authorized Distributor Industrial VFD Cables Index n Variable Frequency Drive
KNOW YOUR OPTIONS: 69 KV XLPE POWER CABLE
Know Your Options: 69 kv XLPE Power Cable 3 material and size material is a matter of both customer preference and required current carrying capacity Copper conductor common for larger loads When both
Corporate Profile ROYAL. MODERN ROYAL ELECTRIC Ideal Power Solution MRE ELECTRICAL, INSTRUMENTATION & COMMUNICATION SYSTEMS
Corporate Profile MODERN ROYAL ELECTRIC Ideal Power Solution ROYAL MRE ELECTRICAL, INSTRUMENTATION & COMMUNICATION SYSTEMS MAJOR STOCKIST >>> CATHODIC PROTECTION CABLES >>> LOW VOLTAGE CABLES >>> MEDIUM
High Voltage Systems. Today. The history of cables
High Voltage Cables High Voltage Systems Today Prysmian Cables and Systems B.V. is part of the Prysmian Group, a leading player in the industry of high-technology cables and systems for energy and telecommunications,
3.6/6 kv XLPE insulated cables 5. 6/10 kv XLPE insulated cables 15. 8.7/15 kv XLPE insulated cables 25. 12/20 kv XLPE insulated cables 35
CONTENTS INTRODUCTION 1 Cable selection, cable specification, cable services CABLES Constructional data: 3.6/6 kv XLPE insulated cables 5 SECTION 1 6/10 kv XLPE insulated cables 15 SECTION 2 8.7/15 kv
PVC YALITIMLI SÝNYAL VE KONTROL KABLOLARI PVC INSULATED SIGNAL AND CONTROL CABLES (VDE 0812-VDE 0814-VDE 0245)
LÝYY KABLO YAPISI: CONSTRUCTION: 1- ÝLETKEN : IEC-228 ;DIN VDE 0295;HD 383 SINIF-5 ELEKTROLÝTÝK BÜKÜLÜ BAKIR 2- YALITKAN : DIN VDE 0207 BÖLÜM-4 YI2 PVC KOMPAUND 3- YALITIM RENK : DIN 47100 4- BÜKÜM : UYGUN
The Handbook 2013 EDITION
The Handbook 2013 EDITION Trust Als you safe Alsecure is the cable you can stake your reputation on when safety and security are critical to maintain circuit integrity for mains power, lighting, alarms,
Gexol. Gexol. The Global Cable Solutions Company. Designed for safe, reliable performance in the harshest oil and gas operating environments
Gexol Gexol World Class World Class Designed for safe, reliable performance in the harshest oil and gas operating environments Power Control Instrument VFD The Global Cable Solutions Company Gexol World
3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance
SPECIFICATION FOR LOW VOLTAGE SWITCHBOARD SEN I N D E X Description 10 STANDARD TECHNICAL REQUIREMENTS 11 Standards 12 General Operating Conditions 13 General Description Of Switchboard 131 Structure 132
EDS 02-0027 11KV TRIPLEX CABLE
THIS IS AN UNCONTROLLED DOCUMENT, THE READER MUST CONFIRM ITS VALIDITY BEFORE USE Document Number: EDS 02-0027 ENGINEERING DESIGN STANDARD EDS 02-0027 11KV TRIPLEX CABLE Network(s): EPN, LPN, SPN Summary:
Important Information: Complete Terms and Conditions are printed on sales invoices
Important Information: Complete Terms and Conditions are printed on sales invoices Notice: L&H Group is continually working to improve and add new products to the Cable Express product range. For this
Removal of EP 20 10 00 02 SP High Voltage Cable
TN 018: 2014 Technical Note For queries regarding this document [email protected] www.asa.transport.nsw.gov.au TN 018: 2014 Issued date 12 March 2014 Effective dates 12 March 2014 Subject:
YOUR SAFETY IS IMPORTANT. Low fire hazard cables. PRAKAB
PRAGUE SAINT PETERSBURG YOUR SAFETY IS IMPORTANT. Low fire hazard cables. PRAKAB PRAGUE SCHWECHAT NITRA KIEV PRAKAB PRAŽSKÁ KABELOVNA, s.r.o. Ke Kablu 278 CZ-102 09 Praha 15 Tel. +420 272 070-111 Fax +420
Marine & Shipboard Cable JIS C 3410(1999) IEC 60092-350, 353, 354, 376
T o t a l S o l u t i o n o f M a r i n e C a b l e Marine & Shipboard Cable JIS C 3410(1999) IEC 60092-350, 353, 354, 376 Marine & Shipboard cable Total Solution of Marine Cable JIS C 3410(1999), IEC
CONTENT. Robot cables. page. < The company... 3. < W - worldwide... 4. < Certifications... 5. < Clientele / supplier numbers... 6
CONTENT page < The company............................................................................... 3 < W - worldwide...............................................................................
VDE Information. Degree of Pollution, Clearances and Creepage Distances and Insulating Materials
VDE Information General Information The voltage which can be applied to a terminal depends on the relevant regulations, the installation conditions and, of course, the dimensions and insulating materials
Outside Telephone Cable
Outside Telephone Cable Filled Core. Moisture Barrier. Description Soft copper wires insulated with high density polyethylene, foam skin or solid. Filled core, conformed by groups of pairs or by unit of
Offshore Transformer Platform. Technical Standard. Energinet.dk. HV, MV, LV and Signal Cables and Cable Routing
Offshore Transformer Platform Technical Standard Energinet.dk HV, MV, LV and Signal Cables and Cable Routing ETS - 03 Rev. 1 Acadre doc. 44858-09 Revision survey Chpt. Description Revision Date Resp. -
MICROCABLES. A complete vision of your connectivity needs. Catalogue
MICROCABLES A complete vision of your connectivity needs Catalogue ELECTRONIC Filotex Introduction Application Nexans s line of microcables is designed towards the increasing requirements of electronics
Copper Cables CONNECTIVITY & CABLING SYSTEM
Copper Cables CONNECTIVITY & CABLING SYSTEM Category 5E M0502057-91 EN CPR 6707 U/UTP tested up to 200 MHz U/UTP CAT5E, unshielded 4-pair cable (100 Ohm), with PVC or LSZH (Low Smoke Zero Halogen) outer
FIBER-OPTIC CABLES LWL-KABEL
FIBER-OPTIC CABLES LWL-KABEL FIBER-OPTIC LOOSE TUBE OUTDOOR CABLE LWL-BÜNDELADER AUSSENKABEL TECHNISCHE DATEN - Technical Data A-DQ(ZN)B2Y 1200 N A-DQ(ZN)B2Y 2500 N ECO-KABEL - ECO cable STANDARDKABEL
Industrial Cable Solutions for Variable Frequency Drives
Industrial Cable Solutions for Variable Frequency Drives Tough challenges call for innovative solutions, and General Cable is your worldwide source for new products and a wide range of industry-leading
CABLE 101. The Basics of Wire & Cable. Copyright 2007, Belden Inc.
CABLE 101 The Basics of Wire & Cable Copyright 2007, Belden Inc. KEY TERMS Insulations Jacket Capacitance Attenuation Velocity of propagation Dielectric strength Dielectric constant Working voltage Elongation
6 ELECTRICAL PARAMETERS
6 ELECTRICAL PARAMETERS For power, low voltage and medium voltage cables, cross section nominal areas are calculated in taking into account several parameters as: permissible current carrying capacities