Quality Reliability Innovation. ISO 9001 : 2000 CERTIFIED BY AFAQ No. QUAL / 1997 / 7034 a COPPER TELECOMMUNICATION CABLES
|
|
- Bertha McCormick
- 7 years ago
- Views:
Transcription
1 Quality Reliability Innovation ISO : CERTIFIED BY AFAQ No. QUAL / 7 / 7 a COPPER TELECOMMUNICATION CABLES
2
3 COPPER TELECOMMUNICATION CABLES
4 CONTENTS 7 NOTICE INTRODUCTION QUALITY ASSURANCE RECOMMENDED ORDERING PARAMETERS OUR TYPE AND CODE DESIGNATION DUCT, UNDERGROUND NETWORK CABLES USED IN FEEDER AND DISTRIBUTION. - PE insulated, Petroleum jelly filled, PE sheathed. - PE insulated, PE sheathed DIRECT BURIAL, UNDERGROUND NETWORK CABLES USED IN FEEDER AND DISTRIBUTION 7. - PE insulated, Petroleum jelly filled, double steel tape armoured, PE sheathed 7. - PE insulated, double steel tape armoured, PE sheathed FIGURE AERIAL NETWORK CABLES USED IN DISTRIBUTION. - PE insulated, Petroleum jelly filled, PE sheathed, with steel messenger. - PE insulated, PE sheathed, with steel messenger. - PE insulated, Petroleum jelly filled, double steel tape armoured, PE sheathed, with steel messenger. - PE insulated, double steel tape armoured, PE sheathed, with steel messenger INDOOR USE TELEPHONE CABLES, PVC INSULATED AND PVC SHEATHED JUMPER WIRE DROP WIRE ANNEX A - INDENTIFICATION OF CONDUCTORS AND UNITS AND CABLE CORE CONSTRUCTION OF UNDERGROUND AND AERIAL NETWORK CABLES ANNEX B - IDENTIFICATION OF CONDUCTORS OF INDOOR USE TELEPHONE CABLE - LIBTEL P a g e 7
5 NOTICE As this catalogue is not intended to cover all of LIBAN CABLES S A L possibilities in Copper Telephone Cables manufacturing, the hereafter listing of the types of cables is not restrictive but only indicative of the main and most current types we manufacture. On the other hand, our specification sheets are inspired mainly from International Electrotechnical Commission Specifications (IEC) only in order to conform with the sustained trend, noticed both regionally and worldwide, towards these same IEC supposed to inspire any further standardization approaches. That is why, while consulting this brochure, it is important to keep in mind that: - any combination or change of the constructional details mentioned in hereafter chapter remains feasible, on base of special conception development, matching any special or different specifications, - we can offer additional possibilities and alternatives like for example: - Pair, quad, and other basic formations - Unit or concentric stranding - Comparted construction (ex: MIC cables) - our production encompasses all telecom cables of low, high or special mutual capacitance and conductor gauges mm. F i n a l l y, and within our policy of constant improvement, we reserve the right to alter any part of the information contained in this publication without incurring any obligation. In all cases this brochure being only indicatve, and unless expressly agreed upon, it cannot be considered by any mean as contractual document.
6 INTRODUCTION Devoted to the manufacturing of electric and telecom cables, Liban Cables is the first and largest supplier in Lebanon and a leader in the Middle-East region. Liban Cables was founded in 7 by a group of Lebanese industrialists backed up by the technical assistance of two international leading firms : - Les Cables de Lyon - France (became A L C AT E Lafterwards and NEXANS by end ) - Phelps Dodge - U.S.A. S t a ffed with qualified engineers and highly skilled technicians, our plant is located in Nahr-Ibrahim at Km from Beirut, where cables are designed and manufactured according to all international specifications : IEC, VDE, UTE, BS and others on customer request. Early after its foundation, Liban Cables has become the major supplier of the Lebanese market in both the public and private sectors. The product range of Liban Cables covers all Copper and Aluminium electric cables, as well as copper and fiber optic communication cables, in addition to a wide variety of special cables manufactured on customer request. High quality cables, continuous developments of the production range, direct and fast shipments have contributed in rendering Liban Cables an important exporter for many countries on the three limitrophe continents (Asia, Europe, Africa). Liban Cables products are particularly appreciated by administrations and international contractors operating in the region and seeking reliable and direct supplies of power and communication cables.
7 QUALITY Step by step, from raw material to final product, quality constitutes a major concern to Liban Cables. Raw material are continuously and repetitively tested from trial orders till the last batch received afterwards. Products are tested within two simultaneous procedures : - A built in quality control system carried out by the production itself at any step of work in process. - A parallel and contradictory procedure is also carried out on the same stages and products by independent inspectors reporting to the quality control service. End users and/or third part inspection authorities are also constantly commissioning the finished products and assessing the strict conformity to ordered specifications. In fact, our ISO certification stated in Feb 7 by the International Certification Network (EQNET) is certified by the French Association for Quality Assurance (AFAQ), the well known rigourous and independant accredited European assessor. T h i s certification, which upgraded to ISO : on February, under reference A FAQ Nº QUAL / 7 / 7 a, confirms the soundness and the performance of the Quality System we apply for the Design, the Development, the Manufacturing and the Marketing & Sales of all our products. RECOMMENDED ORDERING PARAMETERS For prompt quotation / supplies, please make sure your inquiries and your orders are securing the following data : - International or Special Standard. (Alternatively, the precise usage of the cable.) - Constructional details (Materials, Pairs / Quads, Mutual Capacitance, Filling, Screens, Armour, Messenger...etc). - Other requirements - Packing & Tolerances - Required delivery time - Required validity
8 OUR TYPE AND CODE DESIGNATION The type designation is a combination of symbols (letters and numbers) indicating the type, and the main constructional elements of the cable as follows : OUTDOOR CABLES 7 No letter - PE sheath Y - PVC sheath U - Halogen free, Low smoke and fume sheath L - Lead sheath B - Black steel tape armouring G - Galvanized steel tape armouring R - Galvanized round steel wire armouring F - Flat steel wire armouring A- Aluminium tape armouring W - Round aluminium wire armouring Z - One side coated corrugated steel tape K - Two side coated corrugated steel tape S - One side coated aluminium screen D - Two side coated aluminium screen I - Two side coated corrugated aluminium screen Z - Non coated aluminium screen O - Copper tape screen H - Corrugated copper tape screen C - Copper wire screen Q - Lacquered aluminium screen T-Telephone cables P - Solid PE insulation C - Cellular PE insulation M - (Foam / skin) PE insulation Y - PVC insulation - For cables stranded in pairs - For cables stranded in star quads A- Aerial Cables U - Underground / Armoured Cables D - Underground / Duct Cables
9 Example: TUMDG - Telephone cable, underground, pair Type, foam / skin PE insulated, two side coated Aluminium screened, galvanized steel tape armoured. N. B. : The sequence of the rd and th characters indicates whether the cable is jelly filled or not. For jelly filled cables, these two characters are interchanged, i.e. the letter indicating the type of insulation (P,C,M or T) comes before the number indicating the type of stranding ( or ). Examples : TUMDG - Telephone cable, underground, foam / skin PE insulated, pair Type, jelly filled, two side coated Aluminium screened, galvanized steel tape armoured. TUMDG - Same cable but not jelly filled. INDOOR CABLES LIBTEL LIBTLV LIBTLS LIBTLA for unscreened PVC insulated and sheathed cables for tinned copper conductor, PVC insulated and sheathed cables for screened, PVC insulated and sheathed cables for armoured, PVC insulated and sheathed cables
10 DUCTUNDERGROUND NETWORK CABLE USED IN FEEDER AND DISTRIBUTION ( FILLED ). polyethylene insulated longitudinally watertight polyethylene sheathed Specification: Based on IEC 7- and 7- Type and Application Our type TDMD Pulling in duct CONSTRUCTION Conductors Solid annealed bare copper wire of: - -. or. mm nominal. Other wire s are also available. Insulation One layer of fully coloured solid polyethylene, or one layer of colourless cellular polyethylene covered by a thin layer of fully coloured solid polyethylene (foam-skin). Radial thickness determined to satisfy the electrical characteristics. Twisting conductors are twisted into a pair. D i fferent twisting laylengths are used to minimize crosstalk. Quad cables are available upon request. Stranding In sub-units of pairs, for units of or pairs and for cables of up to pairs. In units of or pairs for cables of more than pairs. Other repartition also available. Spare pairs Located within the units or between the units of the outer layer of the cable core, they are used to replace the pairs damaged during the manufacturing process. Cable core construction, identification of conductors and units: see annex A. Longitudinal watertightness The cable core interstices are filled with a suitable compound (petroleum jelly) to avoid longitudinal water penetration inside the cable. Cable core protection One or more tapes helically or longitudinally laid with an overlap. Continuity wire (when specified) One mm tinned copper wire is longitudinally laid to ensure the electrical continuity of the screen. Moisture barrierand screen One or two side ethylene copolymere coated smooth aluminium tape is longitudinally laid with an overlap. thickness of aluminium :. mm. D i fferent or corrugated screen also available. Sheath Black, high, medium or low density polyethylene. radial thickness: as requested or as per the physical characteristics table. Marking manufacturer s identification number of pairs and conductor sequentially numbered length marking at each meter interval (or as requested).
11 Usual electrical characteristics Loop resistance at ºC in direct current Diameter mm..... value Ω/km Maximum individual value Ω/km Dielectric strength during mn in direct current* Between conductors: kv Between conductors and screen : kv * the test can be achieved under alternative current with half of above voltages. Insulation resistance under V minimum direct current Lowest value after mn minimum : MΩ.km. Mutual capacitance at Hz Maximum individual: nf/km. For cables of equal or more than pairs: maximum average: nf/km. cables of low level mutual capacitance ( nf/km) are also available Maximum capacitance unbalance at Hz in pf per meters length of cable. Individual value (pf) % values (pf), &. mm. mm, &. mm. mm Pair-to-pair Side-to-side Pair-to-earth 7 Side-to-earth 7 Maximum calculated attenuation at Hz and ºC ø mm.7 db/km ø mm. db/km ø. mm. db/km ø. mm. db/km 7
12 DUCT UNDERGROUND NETWORK CABLE USED IN FEEDER AND DISTRIBUTION Foam-skin Polyethylene insulated - Petroleum Jelly filled - Polyethylene sheathed (maximum average mutual capacitance nf/km) number of pairs Conductor Usual number of spare pairs Usual nominal delivery length (m) Approx. cable core sheath thickness Approx. nominal outer lineic weight (Kg/Km) * Other conductor gauges, mutual capacitances, different pair count cables and different delivery lengths are also available
13 DUCTUNDERGROUND NETWORK CABLE USED IN FEEDER AND DISTRIBUTION ( AIRCORE ). polyethylene insulated polyethylene sheathed Specification: Based on IEC 7- and 7- Type and Application Our type TDPD Pulling in duct CONSTRUCTION Conductors Solid annealed bare copper wire of: - -. or. mm nominal. Other wire s are also available. Insulation Fully coloured s o l i d (or foam skin when specified) polyethylene. Radial thickness determined to satisfy the electrical characteristics. Twisting conductors are twisted into a pair. D i fferent twisting laylengths are used to minimize crosstalk. Quad cables are available upon request. Stranding In sub-units of pairs, for units of or pairs and for cables of up to pairs. In units of or pairs for cables of more than pairs. Other repartition also available. Spare pairs Located within the units or between the units of the outer layer of the cable core, they are used to replace the pairs damaged during the manufacturing process. Cable core construction, identification of conductors and units: see annex A. Cable core protection One or more tapes helically or longitudinally laid with an overlap. Continuity wire (when specified) One mm tinned copper wire is longitudinally laid to ensure the electrical continuity of the screen. Moisture barrierand screen One or two side ethylene copolymere coated smooth aluminium tape is longitudinally laid with an overlap. thickness of aluminium :. mm. D i fferent or corrugated screen also available. Sheath Black, high, medium or low density polyethylene. radial thickness: as requested or as per the physical characteristics table. Marking manufacturer s identification number of pairs and conductor sequentially numbered length marking at each meter interval (or as requested).
14 Usual electrical characteristics Loop resistance at ºC in direct current Diameter mm..... value Ω/km Maximum individual value Ω/km Dielectric strength during mn in direct current* Between conductors: kv Between conductors and screen : kv * the test can be achieved under alternative current with half of above voltages. Insulation resistance under V minimum direct current Lowest value after mn minimum : MΩ.km. Mutual capacitance at Hz Maximum individual: nf/km. For cables of equal or more than pairs: maximum average: nf/km. cables of low level mutual capacitance ( nf/km) are also available Maximum capacitance unbalance at Hz in pf per meters length of cable. Individual value (pf) % values (pf), &. mm. mm, &. mm. mm Pair-to-pair Side-to-side Pair-to-earth 7 Side-to-earth 7 Maximum calculated attenuation at Hz and ºC ø mm.7 db/km ø mm. db/km ø. mm. db/km ø. mm. db/km
15 number of pairs Conductor DUCT UNDERGROUND NETWORK CABLE USED IN FEEDER AND DISTRIBUTION Solid PE insulated - PE sheathed (maximum average mutual capacitance nf/km) Usual number of spare pairs Approx. cable core sheath thickness Approx. nominal outer lineic weight (Kg/Km) * Other conductor gauges, mutual capacitances, different pair count cables and different delivery lengths are also available Usual nominal delivery length (m)
16 7 DIRECT BURIALUNDERGROUND NETWORK CABLE USED IN FEEDER AND DISTRIBUTION ( FILLED ) 7. polyethylene insulated longitudinally watertight double steel tape armoured polyethylene sheathed CONSTRUCTION Conductors Solid annealed bare copper wire of: - -. or. mm nominal. Other wire s are also available. Insulation One layer of fully coloured s o l i d polyethylene or one layer of colourless c e l l u l a r polyethylene covered by a thin layer of fully coloured solid polyethylene (foam-skin). Radial thickness determined to satisfy the electrical characteristics. Twisting conductors are twisted into a pair. D i fferent twisting laylengths are used to minimize crosstalk. Quad cables are available upon request. Stranding In sub-units of pairs, for units of or pairs and for cables of up to pairs. In units of or pairs for cables of more than pairs. Other repartition also available. Spare pairs Located within the units or between the units of the outer layer of the cable core, they are used to replace the pairs damaged during the manufacturing process. Cable core construction, identification of conductors and units: see annex A. Longitudinal watertightness The cable core interstices are filled with a suitable compound (petroleum jelly) to avoid longitudinal water penetration inside the cable. Cable core protection One or more tapes helically or longitudinally laid with an overlap. Continuity wire (when specified) One mm tinned copper wire is longitudinally laid to ensure the electrical continuity of the screen. Moisture barrierand screen One or two side ethylene copolymere coated smooth aluminium tape is longitudinally laid with an overlap. Specification: Based on IEC 7- and 7- Type and Application Our type TUΜDG Directly buried thickness of aluminium :. mm. D i fferent or corrugated screen also available. Innersheath Colourless or black high (or low when specified) density polyethylene. radial thickness: as requested or as per the physical characteristics table. Armour Double steel tape helically laid on a crepe paper bedding (facultative). The nominal thickness of each tape is. mm or mm (see the physical characteristics table). Outersheath Black low density polyethylene. radial thickness: as requested or as per the physical characteristics table. Marking manufacturer s identification number of pairs and conductor sequentially numbered length marking at each meter interval (or as requested).
17 Usual electrical characteristics Loop resistance at ºC in direct current Diameter mm..... value Ω/km Maximum individual value Ω/km Dielectric strength during mn in direct current* Between conductors: kv Between conductors and screen : kv * the test can be achieved under alternative current with half of above voltages. Insulation resistance under V minimum direct current Lowest value after mn minimum : MΩ.km. Mutual capacitance at Hz Maximum individual: nf/km. For cables of equal or more than pairs: maximum average: nf/km. cables of low level mutual capacitance ( nf/km) are also available Maximum capacitance unbalance at Hz in pf per meters length of cable. Individual value (pf) % values (pf), &. mm. mm, &. mm. mm Pair-to-pair Side-to-side Pair-to-earth 7 Side-to-earth 7 Maximum calculated attenuation at Hz and ºC ø mm.7 db/km ø mm. db/km ø. mm. db/km ø. mm. db/km
18 DIRECT BURIAL UNDERGROUND NETWORK CABLE USED IN FEEDER AND DISTRIBUTION Foam-skin Polyethylene insulated - Petroleum Jelly filled Double steel tape armoured - Polyethylene sheathed (maximum average mutual capacitance nf/km) Number of pairs Conductor Usual number of spare pairs Steel tape thickness Approx. nominal outer Usual nominal delivery length (m) lineic weight (Kg/Km) sheath thickness Approx. cable core inner outer * Other conductor gauges, mutual capacitances, different pair count cables and different delivery lengths are also available
19 7 DIRECTBURIALUNDERGROUND NETWORK CABLE USED IN FEEDER AND DISTRIBUTION ( AIRCORE ) 7. polyethylene insulated double steel tape armoured polyethylene sheathed Specification: Based on IEC 7- and 7- Type and Application Our type TUPDG Directly buried CONSTRUCTION Conductors Solid annealed bare copper wire of: - -. or. mm nominal. Other wire s are also available. Insulation Fully coloured solid (or foam skin when specified) polyethylene. Radial thickness determined to satisfy the electrical characteristics. Twisting conductors are twisted into a pair. D i fferent twisting laylengths are used to minimize crosstalk. Quad cables are available upon request. Stranding In sub-units of pairs, for units of or pairs and for cables of up to pairs. In units of or pairs for cables of more than pairs. Other repartition also available. Spare pairs Located within the units or between the units of the outer layer of the cable core, they are used to replace the pairs damaged during the manufacturing process. Cable core construction, identification of conductors and units: see annex A. Cable core protection One or more tapes helically or longitudinally laid with an overlap. Continuity wire (when specified) One mm tinned copper wire is longitudinally laid to ensure the electrical continuity of the screen. Moisture barrierand screen One or two side ethylene copolymere coated smooth aluminium tape is longitudinally laid with an overlap. thickness of aluminium :. mm. Different or corrugated screen also available. Inner sheath Colourless or black high (or low when specified) density polyethylene. radial thickness: as requested or as per the physical characteristics table. Armour Double steel tape helically laid on a crepe paper bedding (facultative). The nominal thickness of each tape is. mm or mm (see the physical characteristics table). Outer sheath Black low density polyethylene. radial thickness: as requested or as per the physical characteristics table. Marking manufacturer s identification number of pairs and conductor sequentially numbered length marking at each meter interval (or as requested).
20 Usual electrical characteristics Loop resistance at ºC in direct current Diameter mm..... value Ω/km Maximum individual value Ω/km Dielectric strength during mn in direct current* Between conductors: kv Between conductors and screen : kv * the test can be achieved under alternative current with half of above voltages. Insulation resistance under V minimum direct current Lowest value after mn minimum : MΩ.km. Mutual capacitance at Hz Maximum individual: nf/km. For cables of equal or more than pairs: maximum average: nf/km. cables of low level mutual capacitance ( nf/km) are also available Maximum capacitance unbalance at Hz in pf per meters length of cable. Individual value (pf) % values (pf), &. mm. mm, &. mm. mm Pair-to-pair Side-to-side Pair-to-earth 7 Side-to-earth 7 Maximum calculated attenuation at Hz and ºC ø mm.7 db/km ø mm. db/km ø. mm. db/km ø. mm. db/km
21 DIRECT BURIAL UNDERGROUND NETWORK CABLE USED IN FEEDER AND DISTRIBUTION Solid Polyethylene insulated - Double steel tape armoured - Polyethylene sheathed (maximum average mutual capacitance nf/km) Number of pairs Conductor Usual number of spare pairs Steel tape thickness Approx. nominal outer Usual nominal delivery length (m) lineic weight (Kg/Km) sheath thickness Approx. cable core inner outer * Other conductor gauges, mutual capacitances, different pair count cables and different delivery lengths are also available
22 AERIALNETWORK CABLE USED IN DISTRIBUTION ( FILLED ). polyethylene insulated longitudinally watertight polyethylene sheathed steel messenger CONSTRUCTION Conductors Solid annealed bare copper wire of: - -. or. mm nominal. Other wire s are also available. Insulation One layer of fully coloured s o l i d polyethylene or one layer of colourless c e l l u l a r polyethylene covered by a thin layer of fully coloured s o l i d polyethylene (foam-skin). Radial thickness determined to satisfy the electrical characteristics. Twisting conductors are twisted into a pair. D i fferent twisting laylengths are used to minimize crosstalk. Quad cables are available upon request. Stranding In sub-units of pairs, for units of or pairs and for cables of up to pairs. In units of or pairs for cables of more than pairs. Other repartition also available. Spare pairs Located within the units or between the units of the outer layer of the cable core, they are used to replace the pairs damaged during the manufacturing process. Cable core construction, identification of conductors and units: see annex A. Longitudinal watertightness The cable core interstices are filled with a suitable compound (petroleum jelly) to avoid longitudinal water penetration inside the cable. Cable core protection One or more tapes helically or longitudinally laid with an overlap. Continuity wire (when specified) One mm tinned copper wire is longitudinally laid to ensure the electrical continuity of the screen. Moisture barrierand screen One or two side ethylene copolymere Specification: Based on IEC 7- and 7- Type and Application Our type TΑΜD Self- supported aerial laying coated smooth aluminium tape is longitudinally laid with an overlap. thickness of aluminium :. mm. Different or corrugated screen also available. Messenger One strand of galvanized steel wires. Diameter of wires, number of wires and minimum breaking strength : as requested or as per the physical characteristics table. Sheath Black, high, medium or low density, figure shaped polyethylene i n c l u d i n g the cable core and the messenger. radial thickness : as requested or as per the physical characteristics table. Marking manufacturer s identification number of pairs and conductor sequentially numbered length marking at each meter interval (or as required).
23 Usual electrical characteristics Loop resistance at ºC in direct current Diameter mm..... value Ω/km Maximum individual value Ω/km Dielectric strength during mn in direct current* Between conductors: kv Between conductors and screen : kv * the test can be achieved under alternative current with half of above voltages. Insulation resistance under V minimum direct current Lowest value after mn minimum : MΩ.km. Mutual capacitance at Hz Maximum individual: nf/km. For cables of equal or more than pairs: maximum average: nf/km. cables of low level mutual capacitance ( nf/km) are also available Maximum capacitance unbalance at Hz in pf per meters length of cable. Individual value (pf) % values (pf), &. mm. mm, &. mm. mm Pair-to-pair Side-to-side Pair-to-earth 7 Side-to-earth 7 Maximum calculated attenuation at Hz and ºC ø mm.7 db/km ø mm. db/km ø. mm. db/km ø. mm. db/km
24 number of pairs Conductor AERIAL NETWORK CABLE USED IN DISTRIBUTION Foam skin Polyethylene insulated - Petroleum jelly filled Polyethylene sheathed - Steel messenger (maximum average mutual capacitance nf/km) Usual number of spare pairs Approx. cable core sheath thickness... Messenger Dim. Nbr.X dia. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. Mini. break load (dan) Nom. outer dimension hght. X dia. X. X. X. X. X.7 X. X. X 7 X. X. X. X. X 7. X.7 X X X. X. X. X. X 7 X X 7 X X. X. X. X X X X * Other conductor gauges, mutual capacitances, different pair count cables and different delivery lengths are also available lineic weight (Kg/Km) Usual nominal delivery length (m) Typical conditions of laying: Maximal distance between the supports (span): m. sag for a m span at ºC without overload:. m. security coefficient > in the following extreme climatic conditions: Hypothesis A: km/h wind speed (pressure: pa) at ºC. Hypothesis B: km/h wind speed (pressure: pa) - ºC without ice. security coefficient > in the following extreme climatic conditions: Hypothesis C: ice sleeve of mm thickness at - ºC without wind.
25 AERIALNETWORK CABLE USED IN DISTRIBUTION ( AIRCORE ). polyethylene insulated polyethylene sheathed steel messenger Specification: Based on IEC 7- and 7- Type and Application Our type TΑΜD Self- supported aerial laying CONSTRUCTION Conductors Solid annealed bare copper wire of: - -. or. mm nominal. Other wire s are also available. Insulation One layer of fully coloured s o l i d polyethylene or one layer of colourless c e l l u l a r polyethylene covered by a thin layer of fully coloured s o l i d polyethylene (foam-skin). Radial thickness determined to satisfy the electrical characteristics. Twisting conductors are twisted into a pair. D i fferent twisting laylengths are used to minimize crosstalk. Quad cables are available upon request. Stranding In sub-units of pairs, for units of or pairs and for cables of up to pairs. In units of or pairs for cables of more than pairs. Other repartition also available. Spare pairs Located within the units or between the units of the outer layer of the cable core, they are used to replace the pairs damaged during the manufacturing process. Cable core construction, identification of conductors and units: see annex A. Cable core protection One or more tapes helically or longitudinally laid with an overlap. Continuity wire (when specified) One mm tinned copper wire is longitudinally laid to ensure the electrical continuity of the screen. Moisture barrierand screen One or two side ethylene copolymere coated smooth aluminium tape is longitudinally laid with an overlap. thickness of aluminium :. mm. Different or corrugated screen also available. Messenger One strand of galvanized steel wires. Diameter of wires, number of wires and minimum breaking strength : as requested or as per the physical characteristics table. Sheath Black, high, medium or low density, figure shaped polyethylene including the cable core and the messenger. radial thickness : as requested or as per the physical characteristics table. Marking manufacturer s identification number of pairs and conductor sequentially numbered length marking at each meter interval (or as required).
26 Usual electrical characteristics Loop resistance at ºC in direct current Diameter mm..... value Ω/km Maximum individual value Ω/km Dielectric strength during mn in direct current* Between conductors: kv Between conductors and screen : kv * the test can be achieved under alternative current with half of above voltages. Insulation resistance under V minimum direct current Lowest value after mn minimum : MΩ.km. Mutual capacitance at Hz Maximum individual: nf/km. For cables of equal or more than pairs: maximum average: nf/km. cables of low level mutual capacitance ( nf/km) are also available Maximum capacitance unbalance at Hz in pf per meters length of cable. Individual value (pf) % values (pf), &. mm. mm, &. mm. mm Pair-to-pair Side-to-side Pair-to-earth 7 Side-to-earth 7 Maximum calculated attenuation at Hz and ºC ø mm.7 db/km ø mm. db/km ø. mm. db/km ø. mm. db/km
27 number of pairs AERIAL NETWORK CABLE USED IN DISTRIBUTION Foam skin Polyethylene insulated - Polyethylene sheathed - Steel messenger (maximum average mutual capacitance nf/km) Conductor Usual number of spare pairs Approx. cable core sheath thickness. Messenger Dim. Nbr.X dia. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. Mini. break load (dan) Nom. outer dimension hght. X dia. X. X. X.7 X. X. X.7 X. X 7 X. X. X.7 X. X. X. X X X. X. X. X. X. X X X X. X 7 X 7. X 7 X X X 7 * Other conductor gauges, mutual capacitances, different pair count cables and different delivery lengths are also available lineic weight (Kg/Km) Usual nominal delivery length (m) Typical conditions of laying: Maximal distance between the supports (span): m. sag for a m span at ºC without overload:. m. security coefficient > in the following extreme climatic conditions: Hypothesis A : km/h wind speed (pressure: pa) at ºC. Hypothesis B : km/h wind speed (pressure: pa) - ºC without ice. security coefficient > in the following extreme climatic conditions: Hypothesis C : ice sleeve of mm thickness at - ºC without wind.
28 AERIALNETWORK CABLE USED IN DISTRIBUTION ( FILLED ). polyethylene insulated longitudinally watertight double steel tape armoured polyethylene sheathed steel messenger CONSTRUCTION Conductors Solid annealed bare copper wire of: - -. or. mm nominal. other wire s are also available. Insulation One layer of fully coloured s o l i d polyethylene or one layer of colourless c e l l u l a r polyethylene covered by a thin layer of fully coloured s o l i d polyethylene (foam-skin). Radial thickness determined to satisfy the electrical characteristics. Twisting conductors are twisted into a pair. D i fferent twisting laylengths are used to minimize crosstalk. Quad cables are available upon request. Stranding In sub-units of pairs, for units of or pairs and for cables of up to pairs. In units of or pairs for cables of more than pairs. Other repartition also available. Spare pairs Located within the units or between the units of the outer layer of the cable core, they are used to replace the pairs damaged during the manufacturing process. Cable core construction, identification of conductors and units: see annex A. Longitudinal watertightness The cable core interstices are filled with a suitable compound (petroleum jelly) to avoid longitudinal water penetration inside the cable. Cable core protection One or more tapes helically or longitudinally laid with an overlap. Continuity wire (when specified) One mm tinned copper wire is longitudinally laid to ensure the electrical continuity of the screen. Specification: Based on IEC 7- and 7- Type and Application Our type TΑΜDG Self- supported aerial laying Moisture barrierand screen One or two side ethylene copolymere coated smooth aluminium tape is longitudinally laid with an overlap. thickness of aluminium :. mm. Different or corrugated screen also available. Innersheath Colourless or black high (or low when specified) density polyethylene. radial thickness: as requested or as per the physical characteristics table. Armour Double steel tape helically laid on a crepe paper bedding (facultative). The nominal thickness of each tape is. mm or mm. Outer sheath Black low density polyethylene. radial thickness: as requested or as per the physical characteristics table. Marking manufacturer s identification number of pairs and conductor sequentially numbered length marking at each meter interval (or as required).
29 Usual electrical characteristics Loop resistance at ºC in direct current Diameter mm..... value Ω/km Maximum individual value Ω/km Dielectric strength during mn in direct current* Between conductors: kv Between conductors and screen : kv * the test can be achieved under alternative current with half of above voltages. Insulation resistance under V minimum direct current Lowest value after mn minimum : MΩ.km. Mutual capacitance at Hz Maximum individual: nf/km. For cables of equal or more than pairs: maximum average: nf/km. cables of low level mutual capacitance ( nf/km) are also available Maximum capacitance unbalance at Hz in pf per meters length of cable Individual value (pf) % values (pf), &. mm. mm, &. mm. mm Pair-to-pair Side-to-side Pair-to-earth 7 Side-to-earth 7 Maximum calculated attenuation at Hz and ºC ø mm.7 db/km ø mm. db/km ø. mm. db/km ø. mm. db/km
30 AERIAL NETWORK CABLE USED IN DISTRIBUTION Foam skin Polyethylene insulated - Petroleum jelly filled - Double steel tape armoured Polyethylene sheathed - Steel messenger (maximum average mutual capacitance nf/km) number of pairs Conductor Usual number of spare pairs Approx. cable core sheath thickness Inner Outer... Messenger Dim. Nbr.X dia. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. Mini. break load (dan) Nom. outer dimension hght. X dia. X. X.7 X. X 7. X.7 X X X X. X. X. X. X X X X X.7 7 X 7. X. X 7 X 7 X 7 X X X 7. X X X X X X 7 * Other conductor gauges, mutual capacitances, different pair count cables and different delivery lengths are also available..... lineic weight (Kg/Km) Usual nominal delivery length (m) Typical conditions of laying: Maximal distance between the supports (span): m. sag for a m span at ºC without overload:. m. security coefficient > in the following extreme climatic conditions: Hypothesis A : km/h wind speed (pressure: pa) at ºC. Hypothesis B : km/h wind speed (pressure: pa) - ºC without ice. security coefficient > in the following extreme climatic conditions: Hypothesis C : ice sleeve of mm thickness at - ºC without wind.
31 AERIALNETWORK CABLE USED IN DISTRIBUTION ( AIRCORE ). polyethylene insulated double steel tape armoured polyethylene sheathed steel messenger Specification: Based on IEC 7- and 7- Type and Application Our type TΑΜDG Self- supported aerial laying CONSTRUCTION Conductors Solid annealed bare copper wire of: - -. or. mm nominal. Insulation One layer of fully coloured s o l i d polyethylene or one layer of colourless c e l l u l a r polyethylene covered by a thin layer of fully coloured s o l i d polyethylene (foam-skin). Radial thickness determined to satisfy the electrical characteristics. Twisting conductors are twisted into a pair. D i fferent twisting laylengths are used to minimize crosstalk. Quad cables are available upon request. Stranding In sub-units of pairs, for units of or pairs and for cables of up to pairs. In units of or pairs for cables of more than pairs. Other repartition also available. Spare pairs Located within the units or between the units of the outer layer of the cable core, they are used to replace the pairs damaged during the manufacturing process. Cable core construction, identification of conductors and units: see annex A. Cable core protection One or more tapes helically or longitudinally laid with an overlap. Continuity wire (when specified) One mm tinned copper wire is longitudinally laid to ensure the electrical continuity of the screen. Moisture barrierand screen One or two side ethylene copolymere coated smooth aluminium tape is longitudinally laid with an overlap. thickness of aluminium :. mm. Different or corrugated screen also available. Inner sheath Colourless or black high (or low when specified) density polyethylene. radial thickness: as requested or as per the physical characteristics table. Armour Double steel tape helically laid on a crepe paper bedding (facultative). The nominal thickness of each tape is. mm or mm Outersheath Black low density polyethylene. radial thickness: as requested or as per the physical characteristics table. Marking manufacturer s identification number of pairs and conductor sequentially numbered length marking at each meter interval (or as required). 7
32 Usual electrical characteristics Loop resistance at ºC in direct current Diameter mm..... value Ω/km Maximum individual value Ω/km Dielectric strength during mn in direct current* Between conductors: kv Between conductors and screen : kv * the test can be achieved under alternative current with half of above voltages. Insulation resistance under V minimum direct current Lowest value after mn minimum : MΩ.km. Mutual capacitance at Hz Maximum individual: nf/km. For cables of equal or more than pairs: maximum average: nf/km. cables of low level mutual capacitance ( nf/km) are also available Maximum capacitance unbalance at Hz in pf per meters length of cable Individual value (pf) % values (pf), &. mm. mm, &. mm. mm Pair-to-pair Side-to-side Pair-to-earth 7 Side-to-earth 7 Maximum calculated attenuation at Hz and ºC ø mm.7 db/km ø mm. db/km ø. mm. db/km ø. mm. db/km
33 number of pairs AERIAL NETWORK CABLE USED IN DISTRIBUTION Foam skin Polyethylene insulated - Double steel tape armoured Polyethylene sheathed - Steel messenger (maximum average mutual capacitance nf/km) Conductor Usual number of spare pairs Approx. cable core 7 7 sheath thickness Inner Outer. Messenger Dim. Nbr.X dia. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. Mini. break load (dan) Nom. outer dimension hght. X dia. X. X. X. X 7. X. X X X X.7 X. X. 7 X. X X 7 X 7 X X. X. 7 X 7. X X X X 7 X X. X. X 7 X 7 X X X * Other conductor gauges, mutual capacitances, different pair count cables and different delivery lengths are also available.... lineic weight (Kg/Km) Usual nominal delivery length (m) Typical conditions of laying: Maximal distance between the supports (span): m. sag for a m span at ºC without overload:. m. security coefficient > in the following extreme climatic conditions: Hypothesis A : km/h wind speed (pressure: pa) at ºC. Hypothesis B : km/h wind speed (pressure: pa) - ºC without ice. security coefficient > in the following extreme climatic conditions: Hypothesis C : ice sleeve of mm thickness at - ºC without wind.
34 INDOOR USE TELEPHONE CABLES USED FOR TELEPHONE EXCHANGES, SWITCHBOARD & PRIVATE TELEPHONE Specification: Based on IEC -/ PVC insulated PVC sheathed Types and Applications LIBTEL LIBTLV LIBTLS LIBTLA Indoor surface and conduit wiring Switchboard cable, tinned conductors Screened Armoured for use where mechanical stresses are encountered CONSTRUCTION Conductors Copper -. mm bare or tinned. Insulation PVC coloured in the mass with surface ring marking for identification. Twisting Pair or other as request. Stranding Concentric including earth continuity insulated tinned wire, protected with overlapped non-hygroscopic tape. Identification of conductors : see annex B. Moisture barrierand screen ( S - type ) Aluminium foil applied with overlap. Armour ( A - type ) double steel tape applied on inner PVC sheath. Outersheath Grey PVC : A rip cord is laid up under the sheath for easy stripping. LIBTEL LIBTLS LIBTLA Usual electrical characteristics Loop resistance at ºC in direct current, max mm tinned. mm tinned.. ohm / km ohm / km ohm / km ohm / km Mutual capacitance at Hz Maximum : nf/km. Insulation resistance min. MΩ.km
35 INDOOR USE TELEPHONE CABLES PVC insulated and PVC sheathed Type LIBTEL LIBTLV Type LIBTELS Type LIBTELA number of pairs Overall Net weight kg / km Overall Net weight kg / km Overall Net weight kg / km Standard Packing Delivery length m CONDUCTOR DIAMETER mm C C C C C C C C C D D D / / / D D D / / / D D D / / / Standard Packing : C : Coils D : Drums Other Sizes are also available
36 JUMPER WIRE Application These cables are intended for inside distributing frame jumper wiring Types JW JWV JWN JWVN PVC insulated tinned copper wire, PVC insulated PVC insulated, nylon jacketed same as JWN but with tinned conductor CONSTRUCTION Conductor Solid, annealed, bare or tinned copper wire, mm. Insulation PVC coloured for identification. Jacket (type JWN and JWVN) abrasion resistant nylon. Stranding Two to five conductors twisted together. Electrical characteristics at ºC Conductor resistance : max Ω / km Insulation resistance : min MΩ / km DIMENSIONAL CHARACTERISTICS Type JW/V Type JWN Number of conductors Overall Net weight kg / km Overall Net weight kg / km Delivery length ( coils ) m CONDUCTOR DIAMETER mm
37 DROP WIRE Application These cables are intended for connecting telephone aerial cable to the subscriber s premises Types DWIRE DWIREY Hard copper conductor, PE jacketed Hard copper conductor, PVC jacketed CONSTRUCTION Conductor Hard copper wire Laid-Up The two conductors are laid-up parallel and jacketed. A ridge is longitudinally extruded along one edge for conductor identification Jacket DWIRE type : Black polyethylene type C to BS DWIREY type: Hard PVC tightly adhered to the conductor type to BS 7 Type DWIRE Electrical characteristics at ºC Conductor resistance, max. - Hard drawn copper. mm. mm. mm... Insulation resistance, min. - PE jacketed - PVC jacketed MΩ. km MΩ. km Copper Conductor mm... DIMENSIONAL CHARACTERISTICS Jacket nature PE PE PE Overall dimensions width x height mm. X.7.7 X.. X. Ω / km Ω / km Ω / km Net weight kg / km Delivery length (coils) m DWIREY... PVC PVC PVC. X.7.7 X.. X. 7
38 ANNEX A IDENTIFICATION OF CONDUCTORS AND UNITS AND CABLE CORE CONSTRUCTION OF UNDERGROUND AND AERIAL NETWORK CABLES ( any othercombination remaining also available on request ) Identification of conductors Pair Nº Colourof insulation Cond. A Cond. B Pair Nº Colourof insulation Cond. A Cond. B blue orange green brown grey 7 red red red red red blue orange green brown grey sub-unit of base ( pairs ) Identification of basic sub-units, construction of and pair units, and cable cores of up to pairs pairs pairs pairs 7 pairs pairs Identification of basic units and cable core constructions forcables of more than pairs - Numbered units 7 pairs ( x p) pairs ( x p) pairs ( x p) pairs ( x p) 7 7 pairs ( x p) pairs ( x p) pairs ( x p) pairs ( x p)
39 Identification of basic units and cable core constructions forcables of more than pairs - Numbered units ( continuation ) 7 7 pairs ( x p) pairs ( x p) pairs ( x p) pairs ( x p) 7 7 pairs ( x p) 7 7 pairs ( x p) pairs (7 x p) pairs ( x p)
40 ANNEX B Identification of conductors in Indooruse telephone cables - LIBTEL Pair Nº etc... WireA Red Blue Yellow Green Black Red Blue Yellow Green Black Red Blue Yellow Green Black Red Blue Yellow Green Black Red Blue Yellow Green Black Red Blue Yellow Green Black Red Blue Colorcode Wire B Basic Ring Red Red Red Red Red Blue Blue Blue Blue Blue Yellow Yellow Yellow Yellow Yellow Green Green Green Green Green Black Black Black Black Black - Color of insulation of triad Wire A : Blue Wire B : Wire C : Red
MEDIUM VOLTAGE CABLES Up to and including 36 KV
MEDIUM VOLTAGE CABLES Up to and including 6 KV NOTICE As this catalogue is not intendedto cover all of LIBAN CABLES SAL possibilities in special cables manufacturing, the hereafter listing of the types
More informationOutside Telephone Cable
Outside Telephone Cable Filled Core. Moisture Barrier. Description Soft copper wires insulated with high density polyethylene, foam skin or solid. Filled core, conformed by groups of pairs or by unit of
More informationOPTICAL FIBER CABLES
OPTICAL FIBER CABLES CONTENTS INTRODUCTION QUALITY ASSURANCE RECOMMENDED ORDERING PARAMETERS GENERALITIES :. Advantage. General Description.. Construction.. Principle TYPICAL SPECIFICATIONS OF OPTICAL
More informationGulf Cable & Electrical Ind. Co.
CONTENTS INTRODUCTION PRODUCT RANGE I PRODUCT DATA TABLES Irrigation 1 Coaxial s for T.V/ Satellite Antenna etc 2 Data Transmission s - 4 pair 24 AWG 3 TELEPHONE CABLES Telephone cables CCP-LAP & CCP-LAP-SS
More informationT A B L E T 1 T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A
T A B L E T 1 1 of 7 Tests & Inspection Cable PCUT & PCUT-A (Table T1) T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A No. Test Scale MOC Requirements G 20:10:001:01 Defined Test
More informationSpecializing in the cable business for over 38 years, PT. SUPREME CABLE
Specializing in the cable business for over 38 years, PT. SUPREME CABLE MANUFACTURING & COMMERCE Tbk. (PT. SUCACO Tbk) has grown steadly to become a largest and leading cable manufacturer, with international
More informationCommunication, Signal & Data Cables
Communication, Signal & Data Cables Used for indoor installation and interconnection of transmission, telephone, telegraph and electronic equipment as well as media equipments www.alfanar.com Communication
More informationTECHNICAL SPECIFICATION FOR LOW-FREQUENCY CABLES AND WIRES WITH PVC INSULATION AND PVC SHEATH
Rev. 1:2007 TECHNICAL SPECIFICATION FOR LOW-FREQUENCY CABLES AND WIRES WITH PVC INSULATION AND PVC SHEATH Suruhanjaya Komunikasi dan Multimedia Malaysia Off Pesiaran Multimedia, 63000 Cyberjaya, Selangor
More informationPROFIBUS cable. for PROFIBUS-PA and -DP 10/63-6.46 EN
for PROFIBUS-PA and -DP 10/63-6.46 EN CPN 080/CPE 080-Ex PROFIBUS-PA basis cable AWG 18, 0.88 mm 2 Use For fixed installation indoor and outdoor, on racks and in conduits. Application Fieldbus cable for
More informationPROFIBUS cable. PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications
Data Sheet 10/63-6.47-EN Rev. D PROFIBUS cable PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications PROFIBUS PA cables Non-Ex (Hazardous) applications Ex (Hazardous) applications
More informationUGVCL/SP/591/11KV HT AB CABLE
TECHNICAL SPECIFICATION FOR 11KV AERIAL BUNCHED CABLES FOR OVERHEAD LINES (CROSSED LINKED POLYTHENE DRY GAS CURED) 1. SCOPE This specification covers requirements of XLPE insulated, 11 KV Aerial Bunched
More informationGulf Cable & Electrical Ind. Co.
CONTENTS INTRODUCTION PRODUCT RANGE I PRODUCT DATA TABLES XLPE INSULATED 600/1000V CABLES Two Core Cables CU/XLPE/PVC/LC/PVC/SWA/PVC 1 Three Core Cables CU/XLPE/PVC/LC/PVC/SWA/PVC 2 Four Core Cables CU/XLPE/PVC/LC/PVC/SWA/PVC
More informationScottishPower Distribution Cables & Equipment. Metal Theft
ScottishPower Distribution Cables & Equipment Metal Theft April 2012 As an aid to deterring to metal theft this booklet has been put together to help identify the types of utility power cables and associated
More informationwww.ptranscable.com We specialize in low voltage cables including: Stranded Single Cable H07V-R Flexible Single Cable H05V-K
P-trans, meaning power transistor, is a well known cable manufacturer based in Aan - Jordan. The production plant produces all sorts of high quality low tension cables and is a leader in the industry supplying
More information3.6/6 kv XLPE insulated cables 5. 6/10 kv XLPE insulated cables 15. 8.7/15 kv XLPE insulated cables 25. 12/20 kv XLPE insulated cables 35
CONTENTS INTRODUCTION 1 Cable selection, cable specification, cable services CABLES Constructional data: 3.6/6 kv XLPE insulated cables 5 SECTION 1 6/10 kv XLPE insulated cables 15 SECTION 2 8.7/15 kv
More information450-750 VOLTS - Copper conductor PVC insulated SSA 1320, IEC 60227 & BS 6004 HO 7V - U With Solid Conductor - TYPE 60227 IEC 01. Insulation Thickness
450 50 VOLTS Copper conductor PVC insulated SSA 320, IEC 6022 & BS 6004 HO V U With Solid TYPE 6022 IEC 0 For internal wiring equipment rated voltage up to 000 V AC and up to 50 V to earth. Catalogue Number
More informationCorporate Profile ROYAL. MODERN ROYAL ELECTRIC Ideal Power Solution MRE ELECTRICAL, INSTRUMENTATION & COMMUNICATION SYSTEMS
Corporate Profile MODERN ROYAL ELECTRIC Ideal Power Solution ROYAL MRE ELECTRICAL, INSTRUMENTATION & COMMUNICATION SYSTEMS MAJOR STOCKIST >>> CATHODIC PROTECTION CABLES >>> LOW VOLTAGE CABLES >>> MEDIUM
More informationCOAX Cables Radio Frequency Cables
COAX Cables Radio Frequency Cables Contents Page Table of contents Pictographs General information Introduction Types and abbreviations Temparature range Construction Characteristics Special constructions
More informationCONFLEX ELECTRIC CABLE
CONFLEX ELECTRIC CABLE CONFLEX - 0.6/1kV Flexible VSD/EMC Cables Applications WW VSD/EMC cables are manufactured for use where electrical interference distorts signal transmission in electric motors. Standard
More informationGlobal cable expertise for rolling stock
Global cable expertise for rolling stock Global cable expertise for rolling stock Single and multicore Low voltage control cables Jumper cables HV roof cables (25 kv) rubber cables for power needs of locomotives
More informationFire Resistant Cables
109/4 Fire Resistant Cables SR 114H Standard - SR 114E Enhanced BS 5839-1 BS 7629-1 BS 6387 BS 8434-1/2 BS 6425 BS 7622 EN 50200 World-wide recognized high quality cables Firecel SR114 are used in: Data
More informationFibre optic cables MDIC LSZH
MDIC LSZH MDIC LSZH - Indoor Access Cable. Micro Drop Installation Cable, special Access cable with low bend radius, no waterpeak G.657.A fibres. Ruggedized construction with excellent performance, easy
More informationRF & Microwave cable assemblies C291
ERTIFIED C AS 9100 RF & Microwave cable assemblies C291 B CONTENTS Pages Introduction... B-4 Specify the right cable for your application... B-5 Finder guide cables vs insertion loss... B-6 to B-7 Flexible
More informationAirdac CNE and SNE, 600/1000V, Polyethylene Sheath, SANS 1507, NRS 063 & NRS 017
Airdac CNE and SNE, 600/1000V, Polyethylene Sheath, SANS 1507, NRS 063 & NRS 017 Conductor: Hard Drawn Copper Conductor Class 2 Insulation: LV-XLPE Phase Color Code(SNE): Red, Black & Bare Copper Phase
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 60502-1 Second edition 2004-04 Power cables with extruded insulation and their accessories for rated voltages from 1 kv (U m = 1,2 kv) up to 30 kv (U m = 36 kv) Part 1: Cables
More informationMICROCABLES. A complete vision of your connectivity needs. Catalogue
MICROCABLES A complete vision of your connectivity needs Catalogue ELECTRONIC Filotex Introduction Application Nexans s line of microcables is designed towards the increasing requirements of electronics
More informationHINDUSTAN PETROLEUM CORPORATION LIMITED ENGINEERING & PROJECTS GRESHAM ASSURANCE HOUSE, 2 ND FLOOR, A-1595(3) 1-A, SIR P M ROAD, FORT MUMBAI-400 001
NEW POL DEPOT AT HINDUSTAN PETROLEUM CORPORATION LIMITED ENGINEERING & S GRESHAM ASSURANCE HOUSE, 2 ND FLOOR, A-1595(3) 1-A, SIR P M ROAD, FORT MUMBAI-400 001 TECHNICAL SPECIFICATION OF XLPE, FRLS LT CABLES
More informationGOWN. Central Loose Tube Cables Outdoor, Steel Wire Armor (SWA) A-DQ(ZN)2YB2Y Full Rodent Protection. Ordering Information.
GOWN Central Loose Tube Cables Outdoor, Steel Wire Armor (SWA) A-DQ(ZN)2YB2Y Full Rodent Protection Ordering Information Belden European Part Numbers Fibre type / count 2 4 6 8 12 16 24 62.5/125-OM1 GOWN102
More information144Fibre SM (G.652) Loose Tube Micro Lite Duct Optical Fibre Cable PRODUCT INFORMATION
Fiber Single Mode Optical Fibre 144 Nos. Sterlite Fiber ITU.T - G.652 D Maximum Cabled Fibre Attenuation db/km 1310nm : 0.36 & 1550nm : 0.23 Loose Tube Filling Jelly Fiber/Tube 24 Nos. Thixotropic jelly
More informationCommercial Coaxial Cable
Commercial Coaxial Cable For the Best in COMMERCIAL TV Reception Solutions! Do you require a Digital TV reception system for your next project? Matchmaster can supply For The Best Design and supply of
More informationVIPERFLEX ELECTRIC CABLE
VIPERFLEX Flexible Low Voltage Electric Cable - 0.6/1kV (Rubber insulated) H07 RN-F & H07 BN-F Single Core 2-Core 2-Core and Earth 3-Core and Earth 4-Core and Earth Multi-Core and Earth H07 RCN-F & H07
More informationCAVEL VS80205 MADE IN ITALY 1000 V
0,05 9,00 x 7,20 (Pet) (LSZH) Attached CE01 CE02 Sheath Colour black black red Non-migrating Polyester tape longitudinally overlapped (Pet) 25 x 23 µm Outer sheath of Thermoplastic material - black - halogen-free,
More informationAPPLICATION ORIENTED DESIGN OF CABLES
APPLICATION ORIENTED DESIGN OF CABLES Mrs. Rohini Bhattacharyya, Dubai cables Ltd.P. O. Box 11529,Dubai. rohinib@ducab.com Mr. Nawaf Ahmad Al Mohaideb Dubai Cables Ltd. P. O. Box 11529, Dubai. Nawaf@ducab.com
More informationRoHS DATA, COAXIAL AND ELECTRONIC M.R. D A TA, C O A X I A L, ECOLGICAL Telecom Cables A N D EL E CTRON I C. Cables
RoHS DATA, COAXIAL AND ELECTRONIC D A TA, C O A X I A L, A N D EL E CTRON I C Cables Index SOLID MULTI-CONDUCTOR CABLES STRANDED MULTI-CONDUCTOR CABLES SPEAKER/ZIP WIRE THERMOSTAT CABLE FIRE ALARM CABLE
More informationThe Quality Connection. BETAflam Fire Resistant Safety Cables
The Quality Connection BETAflam Fire Resistant Safety Cables 2 Contact Consulting and sales Switzerland Phone +41 (0)62 288 82 82 Fax +41 (0)62 288 83 83 sales@leoni-studer.ch www.leoni-infrastructure-datacom.com
More informationGOSB. Central Loose Tube Cables Outdoor A-DQ(ZN)B2Y Standard Rodent Protection. Ordering Information. Applications. Features & Benefits
GOSB Central Loose Tube Cables Outdoor A-DQ(ZN)B2Y Standard Rodent Protection Ordering Information Belden European Part Numbers Fibre type / count 2 4 6 8 12 16 24 62.5/125-OM1 GOSB102 GOSB104 GOSB106
More informationCables, Cable Laying & Accessories Manual
Distribution Business Cables, Cable Laying & Accessories Manual Database ref: File Ref: Title Page & Revision Log For Cables & Access v4 - Nov 2003.doc Manual Name: Cables & Accessories Manual Version
More informationNetwork Standard Advice No. 1420C 9/6/2011
Network Standard Advice No. 1420C 9/6/2011 TO: Customers, Service Providers and Ausgrid Staff. Advisory Note on Changes to the Use of 11kV Cable Types. Introduction This Network Standard Advice (NSA) provides
More informationCHAPTER VIII LINE PLANT SYSTEM COMMUNICATION THROUGH RE CABLE
CHAPTER VIII LINE PLANT SYSTEM COMMUNICATION THROUGH RE CABLE 8.1 SYSTEM 8.1.1 Armoured, screened underground cables are used for control communication in electrified areas to limit induction effect. 8.2
More informationBuilding Cables and Wires
Building Cables and Wires 4 Introduction alfanar is equipped with state-of-the-art manufacturing facilities such as latest machineries, instrumentation, quality control and testing laboratory, etc., for
More informationMarine & Shipboard Cable JIS C 3410(1999) IEC 60092-350, 353, 354, 376
T o t a l S o l u t i o n o f M a r i n e C a b l e Marine & Shipboard Cable JIS C 3410(1999) IEC 60092-350, 353, 354, 376 Marine & Shipboard cable Total Solution of Marine Cable JIS C 3410(1999), IEC
More information108-93018 05 APR 2016 Rev M
Product Specification 108-93018 05 APR 2016 Rev M Copper LAN Cable 1. SCOPE 1.1. Content This specification describes the general requirements for CommScope copper LAN cable. 2. APPLICABLE DOCUMENTS The
More informationFault location on power cables. Fault location on power cables
Fault location on power cables Fault location on power cables Contents: 1. Introduction 2. Construction of power cables 3. Cable faults 01. Introduction Fault location on communication and power cables
More informationTFC/U-JIN Coaxial Cable Product Information Sheet Type: TU6T60-JVB
Type: TU6T60-JVB Dielectric 2nd Outer (w/optional Floodant) Series 6 Coaxial Cable Copper Clad Steel Foamed Polyethylene Dielectric Bonded AP Laminate Shield 60% Aluminum Braid "Life Time" compound AP
More informationMV CABLE TYPE C 33-226
MV CABLE TYPE C 33-226 Standards : CENELEC HD 620 C 33-226 Rated voltage Rated voltage : 12/20 (24) kv Design 1 Stranded aluminium, class 2 conductor 2 Extruded conducting screen on conductor 3 XLPE insulation
More informationLEAD FREE FIREX. Interlock Armored Cables TECK90 and MC Industrial Cables. w w w. n e x a n s e n e r g y. c o m
FIREX Interlock Armored Cables TECK90 and MC Industrial Cables LEAD FREE O V E R 1 8 0 Y E A R S O F E X P E R I E N C E 866-663-9267 w w w. n e x a n s e n e r g y. c o m Interlock Armored Cables Introduction....2
More informationCable Guide. Cables, Connectors & Tools for installation of quality networks. TRIAX - your ultimate connection
Cable Guide Cables, Connectors & Tools for installation of quality networks TRIAX - your ultimate connection A Selection of the best Triax TX Cable range optimised for digital reception Simplification
More informationINTERNATIONAL TELECOMMUNICATION UNION #/.3425#4)/. ).34!,,!4)/.!.$ 02/4%#4)/. /& #!",%3!.$ /4(%2 %,%-%.43 /& /543)$% 0,!.43
INTERNATIONAL TELECOMMUNICATION UNION )454, TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU #/.3425#4)/. ).34!,,!4)/.!.$ 02/4%#4)/. /& #!",%3!.$ /4(%2 %,%-%.43 /& /543)$% 0,!.43 /04)#!, &)"2% #!",%3 &/2
More informationSCHEDULE ' A' TECHNICAL SPECIFICATION FOR 11/22/33KV H.T.XLPE POWER CABLE FOR DISTRIBUTION NETWORK IN MAHARASHTRA (SPECIFICATION NO.
SCHEDULE ' A' TECHNICAL SPECIFICATION FOR 11/22/33KV H.T.XLPE POWER CABLE FOR DISTRIBUTION NETWORK IN MAHARASHTRA (SPECIFICATION NO.MM/I/HTXLPE/2006) MAHARASHTRA STATE ELECTRICITY DISTRIBUTION CO.LTD.
More informationGOSN. Central Loose Tube Cables Outdoor A-DQ(ZN)B2Y Standard Rodent Protection. Ordering Information. Applications. Features & Benefits
GOSN Central Loose Tube Cables Outdoor A-DQ(ZN)B2Y Standard Rodent Protection Ordering Information Belden European Part Numbers Fibre type / count 2 4 6 8 12 16 24 62.5/125-OM1 GOSN102 GOSN104 GOSN106
More informationDATA SHEET SERVO LK SMS FX8PLUS SIGNAL
Application LAPP servo cables according to Siemens * (see footnote) Standard FX8008 PLUS SIGNAL are a new generation of very highly flexible screened signal (encoder and resolver)- cables (P/Ns 00277101
More informationCoaxial cables? Video cables Loudspeaker cables
Photo: ELUKABEL Coaxial cables? Video cables Loudspeaker cables Coaxial cables? Video cables Loudspeaker cables Coaxial cables are used in all areas of the high frequency transmission technology, for example
More informationChemical resistance Accidental
Industrial flexible cable, insulation and outer sheath in elastomer Description Application TITANEX flexible cable is intended for installations with moving equipment, electric appliances and for building
More informationCORNING CABLE SYSTEMS GENERIC SPECIFICATION FOR TIGHT BUFFER OPTICAL FIBER CABLES FOR INTER- AND INTRABUILDING APPLICATIONS.
CORNING CABLE SYSTEMS GENERIC SPECIFICATION FOR TIGHT BUFFER OPTICAL FIBER CABLES FOR INTER- AND INTRABUILDING APPLICATIONS September 2006 Revision 7 Corning Cable Systems reserves the right to update
More informationSECTION 18370 SIGNAL WIRE AND CABLE
SECTION 18370 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for all cable and wire required for signal and signal power system wiring to wayside shelters, junction boxes, and factory
More informationSpecification SFTP CAT6 Network Cable 23AWG CU
Specification SFTP CAT6 Network Cable 23AWG CU S/FTP CAT6 Shielded S/FTP PVC Cable 23AWG 4pair Solid, Wooden drum 1000 Grey CAT6 600MHZ CM Shielded (S/FTP) Solid Cable: Our CAT6 600MHZ Shielded (S/FTP)
More information6 ELECTRICAL PARAMETERS
6 ELECTRICAL PARAMETERS For power, low voltage and medium voltage cables, cross section nominal areas are calculated in taking into account several parameters as: permissible current carrying capacities
More informationTrunk Cables. www.teletronik.com
Trunk Cables www.teletronik.com Brief Introduction Teletronik TC series coaxial cable was developed to meet the increasing demand of tomorrow's broadband networks. TC series cable has the highest reliability
More informationThe Quality Connection. Cable Solutions for Mobile Networks Business Unit Telecom
The Quality Connection Cable Solutions for Mobile Networks Business Unit Telecom Connection Technology for Wireless Communication Systems A consistent focus on the market, in-depth sector and product knowledge,
More informationFibre Optic Indoor/Outdoor Cable
Volition TM Fibre Optic Indoor/Outdoor Cable Tough enough to take it. Easy to handle. The Volition Network Solutions Indoor/Outdoor Fibre Optic Cable from 3M includes horizontal and backbone cable with
More informationTENDER: Tf{/0006120151 A
/ %] *-@*telecom W* namibia TENDER: Tf{/0006120151 A The Supply and Delivery of Various optic fiber cables for the period of thre years For Telecom Namibia Tenderer name: { Total offer: N$. Page 1 of 19
More informationThe color scheme for the fibers in the cable complies with the Telcordia (formerly Bellcore) specification.
10 Cables The cables referred to below are provided with standard single- and multimode fibers. Other commercially available fibers can be provided on request. The bare fibers are colored in all cases
More informationMacArtney Underwater Cables - In stock
MacArtney Underwater Cables - In stock The MacArtney Group depends on the support of a number of major cable manufacturers to supply a range of cables that are designed, manufactured and tested to meet
More information)454, !,5-).)5- #!",% 3(%!4(3 #/.3425#4)/. ).34!,,!4)/.!.$ 02/4%#4)/. /& #!",%3!.$ /4(%2 %,%-%.43 /& /543)$% 0,!.43. )454 Recommendation,
INTERNATIONAL TELECOMMUNICATION UNION )454, TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU #/.3425#4)/. ).34!,,!4)/.!.$ 02/4%#4)/. /& #!",%3!.$ /4(%2 %,%-%.43 /& /543)$% 0,!.43!,5-).)5- #!",% 3(%!4(3
More information2 8 k V, 1 / C, T R X L P E I N S U L A T E D, F L A T S T R A P S H I E L D E D C A B L E, C O M P R E S S E D S T R A N D I N G
Seattle Cit y Light 1 of 4 2 8 k V, 1 / C, T R X L P E I N S U L A T E D, F L A T S T R A P S H I E L D E D C A B L E, C O M P R E S S E D S T R A N D I N G 1. Scope This standard covers the detailed requirements
More informationKNOW YOUR OPTIONS: 230 KV POWER CABLES
KNOW YOUR OPTIONS: 230 KV POWER CABLES 71 CONDUCTOR MATERIAL AND SIZE Conductor material is a matter of both customer preference and required current carrying capacity At 230 kv, copper is most common
More informationFlexible Control Cables
Works photo: KUKA Flexible Control Cables A Flexible Control Cables Since generations people try to build machines and plants which shall take on different functions. To raise, sink, slide, drill, transport
More informationTemperature Permissible ambient temperature. Weather Resistance to severe weather conditions. Impacts Cable mechanical resistance to impacts
Airfield Cables Issue 10/2003 Piktogramme Temperature Permissible ambient temperature Weather Resistance to severe weather conditions Impacts Cable mechanical resistance to impacts Chemical attacks Resistance
More informationETHERLINE Ethernet Cable, Connectors & Tools
Ethernet Cable, ors & Tools 2 Pair 242 4 Pair 249 Industrial Ethernet ors & Tools 256 Ethernet Cable, ors & Tools ETHERNET CABLE, CONNECTORS & TOOLS Quick Select Chart 240 2 Pair 2 Pair: CAT.5/5e; Stationary
More informationKNOW YOUR OPTIONS: 69 KV XLPE POWER CABLE
Know Your Options: 69 kv XLPE Power Cable 3 material and size material is a matter of both customer preference and required current carrying capacity Copper conductor common for larger loads When both
More informationHigh Voltage Systems. Today. The history of cables
High Voltage Cables High Voltage Systems Today Prysmian Cables and Systems B.V. is part of the Prysmian Group, a leading player in the industry of high-technology cables and systems for energy and telecommunications,
More informationStandard Buccaneer - Ethernet
IP6 rated compliant PUR jacket on cable Shielded system shielded coupler Shroud on RJ45 Screw coupling Rewireable flex connector PCB mounted panel connector IDC termination panel connector Earth lead version
More informationCHARACTERISTICS AND ADVANTAGES OF OPTICAL FIBER CABLES
AND ADVANTAGES OF OPTICAL FIBER CABLES ADVANTAGES Low attenuation. Long repeater spacings or repeaterless networks. Wide bandwidth. Large transmission capacity with simultaneous voice, data and video transmission
More informationTECHNICAL SPECIFICATION
TECHNICAL SPECIFICATION 4 PAIR UTP CABLE (ENHANCED CATEGORY 5) PVC (CM Grade) Page 1 of 6 1. SCOPE This specification is based on the specifications of UL 444, ANSI/TIA/EIA-568-B.2, UL 1685 and covers
More informationMEDIUM VOLTAGE POWER CABLES
MEDIUM VOLTAGE POWER CABLES CONTENTS 1 GENERAL INTRODUCTION 4 TECHNICAL INFORMATION 15 25 35 45 Single Core XLPE Insulated PVC Sheathed Cables UNARMOURED CABLES COPPER UNARMOURED CABLES ALUMINUM ALUMINUM
More informationSection 5 161 kv Power Cables
Know Your Options: 161 kv Power Cable 61 material and size material is a matter of both customer preference and required current carrying capacity Copper conductor common for larger loads When both copper
More informationThe Quality Connection. Cables for Data Transmission in Industrial Automation
The Quality Connection Cables for Data Transmission in Industrial Automation Product range Instrumentation- and control cables Thermocouple extension and compensating cables Power cables (low and medium
More informationFlexible cables for submersible products
Flexible cables for submersible products Standards SUBCAB cables complies with the following general standards: IEC 6045 (general) IEC 608 class 5 (conductor) IEC 608-- CLAUSE 9 (oil resistant) IEC 608--
More informationFlygt flexible cables
Flygt flexible cables Contents Standards General SUBCAB 4 Screened SUBCAB 6 Rubber cable type: NSSHÖU-J 7 Screened rubber cable type: NSSHÖU../E + ST 8 FGB screened rubber cable 9 PUR control cable 0 HCR
More informationCatalogue Câbles d Energie
Catalogue Câbles d Energie Conductores Tecnológicos S.A. www.contecsa.es Index Page Introduction 13 RV 14 RVMV 15 RVSV 16 RVFV 17 Conductores Tecnológicos S.A. 2 www.contecsa.es INTRODUCTION Câbles d Energie
More informationFIRE RESISTANT CABLE CONSTRUCTION OF CABLES
FIRE RESISTANT CABLE In all fire disasters, fire smoke, heat and toxic fumes are the main obstacles to safe evacuation of a building or area. A major contribution towards overcoming these hazards is the
More informationFlexible and safe solutions, for decades. Cables for alarmand safety systems
Flexible and safe solutions, for decades. Cables for alarmand safety systems 2 We offer the widest range of cables on the market for every kind of installation. It s all about reliability. It is always
More informationBroadcast and Commercial AV Cabling MASTER CATALOG
Broadcast and Commercial AV Cabling MASTER CATALOG Clark Wire & Cable 408 Washington Blvd. Mundelein, IL 60060 800-222-5348 toll free 847-949-9944 local 847-949-9595 fax www.clarkwire.com Specifications
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 61156-5 First edition 2002-03 Multicore and symmetrical pair/quad cables for digital communications Part 5: Symmetrical pair/quad cables with transmission characteristics up
More informationInstrumentation Cable...14-17. Power Cable...2-11. Assembly Solutions...32
Severe Cold Durability Exceeds CSA Cold Bend / Cold Impact (-0 C/-35 C) Drilling Mud Resistant Flame Retardant Certified to IEC 9-3 (33-3A) and IEEE 580 Oil Resistant Assemblies...3-33 Ester Based Mud
More informationStandards Affecting a Premise T-1 Installation
Standards Affecting a Premise T-1 Installation The T-carrier system originated many years ago as a technology developed by AT&T. The intended use of the scheme was to increase the voice channel capacity
More informationOPTICAL FIBRE CABLES. for very-high bit transmission and FTTx networks
OPTICAL FIBRE CABLES for very-high bit transmission and FTTx networks OPTICAL FIBRE CABLES SILEC CABLE REFERENCES AND KNOW-HOW Since 1983, Silec Cable has successfully supplied the major telecom operators,
More informationImportant Information: Complete Terms and Conditions are printed on sales invoices
Important Information: Complete Terms and Conditions are printed on sales invoices Notice: L&H Group is continually working to improve and add new products to the Cable Express product range. For this
More informationwww.klmtechgroup.com TABLE OF CONTENT
Page : 1 of 13 Project Engineering Standard www.klmtechgroup.com KLM Technology #03-12 Block Aronia, Jalan Sri Perkasa 2 Taman Tampoi Utama 81200 Johor Bahru Malaysia ELECTIRAL GROUNDING TABLE OF CONTENT
More information140 146 rue E. Delacroix / BP 1 F 91211 Draveil cedex FRANCE Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70. Issue 2 01/10/2003-2 -
Space cables Issue 2 01/10/2003-2 - C O N T E N T ESCC Qualified Products Nexans P/N ESCC SP Pages 1871-871 3901/001 359 3/8 1872-872 3901/002 358 9/14 MTV - BTV 3901/013 199 15/19 50 CIS 3902/001.01 189
More informationDrop cables. Vorstadt 32 CH, 6304 Zug Switzerland. teletronik@teletronik.com www.teletronik.com
Drop cables Vorstadt 32 CH, 6304 Zug Switzerland AG teletronik@teletronik.com www.teletronik.com Brief Introduction Teletronik RG series coaxial cable was developed to meet the increasing demand of tomorrow's
More informationRADOX railway cables acc. to EN 50264 and EN 50306. Edition 2009
RADO railway cables acc. to EN 50264 and EN 50306 Edition 2009 Bridging our know how Interdisciplinary knowledge The HUBER+SUHNER Group is a leading international manufacturer of electrical and optical
More informationThe National Armored Cable Manufacturers Association Presents. Installation Standard for Types AC and MC Cables
The National Armored Cable Manufacturers Association Presents Installation Standard for Types AC and MC Cables An ANSI Standard Original document jointly produced by NECA and NACMA as Standard for Installing
More informationDraka Industrial Cable GmbH
A) Preparation of cable ends To enable the stranding of the cores after connecting main and earth cores, each of the cable ends to be connected are laid in a double loop with righthand turn and then fixed
More informationGexol. Gexol. The Global Cable Solutions Company. Designed for safe, reliable performance in the harshest oil and gas operating environments
Gexol Gexol World Class World Class Designed for safe, reliable performance in the harshest oil and gas operating environments Power Control Instrument VFD The Global Cable Solutions Company Gexol World
More informationwith coloured cores and overall copper screen UL/CSA... 17
CONTENT Cable Track Cables y SD 200 extremely flexible TPE/PUR data cable with coloured cores for continuous movement..... 6 y S 200 extremely flexible TPE/PUR control cable with numbered cores for continuous
More informationFestoon 715 P PUR cable for flexible application in festoon systems
CABLES FOR CRANE AND CONVEYOR APPLICATIONS Festoon 715 P PUR cable for flexible application in festoon systems S AB BRÖCKSKES D-VIERSEN Festoon 715 P 1 x 16.0 mm 2 C Marking for Festoon 715 P 07150162:
More informationOffshore Transformer Platform. Technical Standard. Energinet.dk. HV, MV, LV and Signal Cables and Cable Routing
Offshore Transformer Platform Technical Standard Energinet.dk HV, MV, LV and Signal Cables and Cable Routing ETS - 03 Rev. 1 Acadre doc. 44858-09 Revision survey Chpt. Description Revision Date Resp. -
More informationThe Contractor shall furnish and install all shielded power cable suitable for use on this project.
Section 16122 PRIMARY POWER CABLES PART 1 GENERAL: WORK INCLUDED The Contractor shall furnish and install all shielded power cable suitable for use on this project. RELATED WORK Section 16020: Tests SUBMITTALS
More informationIEEE POWER ENGINEERING SOCIETY CHICAGO CHAPTER THE OKONITE COMPANY WEDNESDAY JANUARY 11, 2006 JIM FITZGERALD ENGINEERING LINGO
IEEE POWER ENGINEERING SOCIETY CHICAGO CHAPTER THE OKONITE COMPANY WEDNESDAY JANUARY 11, 2006 JIM FITZGERALD ENGINEERING LINGO WHEN YOU HEAR AN ENGINEER SAY A NUMBER OF DIFFERENT APPROACHES ARE BEING IMPLEMENTED
More information