1 MV CABLE TYPE C Standards : CENELEC HD 620 C Rated voltage Rated voltage : 12/20 (24) kv Design 1 Stranded aluminium, class 2 conductor 2 Extruded conducting screen on conductor 3 XLPE insulation 4 Grooved, strippable, extruded conducting screen on insulation 5 Swellable powder for longitudinal watertightness under the metallic screen 6 Aluminium foil longitudinally applied with an overlap and stuck to the outer sheath 7 PE sheath (*) 8 The three phase conductors may be bundled with a long lay length (*) Red sheath for underground connections. Grey sheath for overhead connections and laying in tunnels Application Specially designed for power distribution networks; designed to be buried directly in the ground. Excellent Good Medium (**) (**) only the cable with a grey sheath in flame retardant (C2 of NFC or IEC ) Using minimum bending radius during laying (single core or bundle) : 26 x diameter of a phase conductor minimum bending radius after laying (single core or bundle) : 13 x diameter of a phase conductor Maximum allowable temperature During continuous service: 90 C During short-circuit: 250 C 1
2 C (continued) Identification and outer marking SILEC Day Year C Cross-section Al 12/20 (24) kv SIPRELEC 23 POPY (1) G2 SC 0,7 AT T -10/50 (2) PHASE 1 (or 2 or 3) (1) Reference for the cable fittings (2) T 0/35 for grey-sheathed cable Length marking on one conductor. Dimension CABLE outer diameter mm weight kg/km Maximum allowable pulling force, dan 1x50 mm² 29, x95 mm² 32, x150 mm² 32, x240 mm² 36, x50 mm² x95 mm² 69, x150 mm² 69, x240 mm² 78, Electrical characteristics Cross-section, mm² Item DC maximum resistance of the conductor at 20 C, Ω / km 0,641 0,320 0,206 0,125 AC apparent resistance of the conductor at 90 C, Ω / km (1) 0,820 0,410 0,265 0,160 Self-induction coefficient, mh / km (1) 0,440 0,400 0,350 0,330 Capacitance, µf / km 0,180 0,220 0,300 0,360 (1) These values are applicable to a three-phase system made of three conductors bundled or in joined trefoil formation. For other cross-sections, please contact us. 2
3 C (continued) Maximum allowable ampacity Cross section, mm² Buried Winter Summer Ampacity in Ampere is calculated for a three phase system, with the below thermal hypothesis, without any electric parallel nor thermal proximity.: SUMMER: soil temperature : 20 C soil thermal resistivity : 1,2 K m / W WINTER: soil temperature : 10 C soil thermal resistivity : 0,85 K m / W For other cross-sections, please contact us. Allowable ampacity during short-circuit in the screen Cross-section, mm² Icc, A during 1 sec For other cross-sections, please contact us. 3
4 ALL GROUND CABLE type UTE C or NF C Standards : UTE C of December 1999 CENELEC HD 620 NFC IEC Rated voltage This design can be manufactured for all rated voltage of IEC Design Stranded conductor, class 2 Extruded conducting screen on conductor XLPE insulation Grooved, strippable, extruded conducting screen on insulation Swellable powder for longitudinal watertightness under the metallic screen Aluminium foil longitudinally applied with an overlap and stuck to the outer sheath, PVC sheath, Strippable, grooved, TPR sheath The three phase conductors may be bundled with a long lay length Using Cable for MV distribution networks. It can be buried directly in all grounds, and is specially adapted for «hard» ground. Mainly, its design prevents from adding sand in the trench bottom, and the trench can be filled back with original soil. Very good Good Medium Setting up the minimum bending radius during installation is the same that NF C or UTE C (see dimension) the minimum bending radius after installation is the same that NF C or UTE C (see dimension) Fitting of a termination or a joint : - Once the grooved outer sheath has been removed with the usual tool, the fitting of a termination or a joint is the same as for NF C or UTE C
5 All Ground Cable type UTE C or NF C (continued) Maximum allowable temperatures Continuous service: 90 C Short-circuit in the conductor: 250 C Short-circuit in the metallic screen : 200 C Identification and outer marking SILEC «Batch number» «Standard» cross section AL 12/20 (24) kv SIPRELEC 23 Ec=0.2 mm PHASE 1 (or 2 or 3) ALL GROUND CABLE Length marking can be indicated on one phase conductor. Dimension outer diameter weight Minimum bending Minimum bending radius Maximum pulling force ARTICLE radius after during laying laying mm mm kg/km mm dan 1 x 50 mm² 39, x 95 mm² x 150 mm² 43, x 240 mm² 48, x 50 mm² 84, x 95 mm² 92, x 150 mm² 93, x 240 mm² 103, Electrical characteristics Cross Section, mm² Item Maximum DC resistance at 20 C, Ω / km 0,641 0,320 0,206 0,125 AC apparent resistance of the conductor at 90 C, Ω / km 0,820 0,410 0,260 0,160 Self-induction coefficient mh / km (1) 0,500 0,450 0,420 0,380 Capacitance, µf / km 0,180 0,210 0,290 0,360 (1) Calculated for three bundled cables or three cables in a joined trefoil formation. For other sections, call us. 5
6 All Ground Cable type UTE C or NF C (continued) Maximum allowable ampacity Cross section, mm² Buried cables Winter Summer Ampacity is indicated in amps for a three-phase system without any thermal or electrical proximity under following thermal conditions: SUMMER: soil temperature : 20 C soil thermal resistivity : 1,2 K m / W WINTER: soil temperature : 10 C soil thermal resistivity : 0,85 K m / W For other sections, call us. 6
7 ALL GROUND CABLE TM type C Standards : UTE C , HD 620, Rated voltage Rated voltage: 12/20 (24) kv Design Stranded conductor, class 2 Extruded conducting screen on conductor XLPE insulation Grooved, strippable, extruded conducting screen on insulation Swellable powder for longitudinal watertightness under the metallic screen Aluminium foil longitudinally applied with an overlap and stuck to the outer sheath, PE sheath, Strippable, grooved, TPR sheath The three phase conductors may be bundled with a long lay length Using Cable for MV distribution networks. It can be buried directly in all grounds, and is specially adapted for «hard» ground. Mainly, its design prevents from adding sand in the trench bottom, and the trench can be filled with original soil. Very good Good Medium Setting up the minimum bending radius during installation is the same that C (see dimension) the minimum bending radius after installation is the same C (see dimension) Fitting of a termination or a joint : - Once the grooved outer sheath has been removed with the usual tool, the fitting a termination or a joint is the same as for standard MV cables 7
8 All Ground Cable type C (continued) Maximum allowable temperatures Continuous service: 90 C Short-circuit in the conductor: 250 C Identification and outer marking SILEC Day Year C Cross-section Al 12/20 (24) kv SIPRELEC 23 POPY (1) G2 SC 0,7 AT T -10/50 (2) PHASE 1 (or 2 or 3) ALL GROUND CABLE (3) Reference for the cable fittings (4) T 0/35 for grey-sheathed cable Metric marking can be indicated on one phase conductor. Dimension ARTICLE outer diameter weight Minimum bending radius after laying Minimum bending radius during laying mm Maximum pulling force mm kg/km mm dan 1 x 50 mm² 38, x 95 mm² 41, x 150 mm² 41, x 240 mm² 45, x 50 mm² 81, x 95 mm² 88, x 150 mm² 88, x 240 mm² 97,
9 All Ground Cable type C (continued) Electrical characteristics Cross section, mm² Characteristics Maximum DC resistance at 20 C, Ω / km 0,641 0,320 0,206 0,125 AC apparent resistance of the conductor at 90 C, Ω / km 0,820 0,410 0,270 0,160 Self-induction coefficient, mh / km (1) 0,500 0,450 0,400 0,370 Capacitance, µf / km 0,180 0,220 0,300 0,360 (1) Calculated for three bundled cables or three cables in a joined trefoil formation. For other sections, please contact us. Maximum allowable ampacity under continuous load Cross section, mm² Buried cables Winter Summmer Ampacity is indicated in amps for a three-phase system without any thermal or electrical proximity under following thermal conditions: SUMMER: soil temperature : 20 C soil thermal resistivity : 1,2 K m / W WINTER: soil temperature : 10 C soil thermal resistivity : 0,85 K m / W For other sections, please contact us. Maximum allowable ampacity in the screen under short-circuit Cross Section, mm² Icc, A during 1 second For other sections, please contact us. 9
MEDIUM VOLTAGE CABLES Up to and including 36 KV
MEDIUM VOLTAGE CABLES Up to and including 6 KV NOTICE As this catalogue is not intendedto cover all of LIBAN CABLES SAL possibilities in special cables manufacturing, the hereafter listing of the types
FLEXIBLE INDUSTRIAL CABLES H07RN-F TENAFLEX SR
FLEXIBLE INDUSTRIAL CABLES H07RN-F TENAFLEX SR Standards : CENELEC HD 22.4 NF C 32-102-4 DIN VDE 0282-1 and VDE 0282-4 BS 6007 and BS 6500 IEC 60245-4 Rated voltage Rated voltage: 450/750 V (Use up to
CONFLEX ELECTRIC CABLE
CONFLEX ELECTRIC CABLE CONFLEX - 0.6/1kV Flexible VSD/EMC Cables Applications WW VSD/EMC cables are manufactured for use where electrical interference distorts signal transmission in electric motors. Standard
High Voltage Systems. Today. The history of cables
High Voltage Cables High Voltage Systems Today Prysmian Cables and Systems B.V. is part of the Prysmian Group, a leading player in the industry of high-technology cables and systems for energy and telecommunications,
Gulf Cable & Electrical Ind. Co.
CONTENTS INTRODUCTION PRODUCT RANGE I PRODUCT DATA TABLES XLPE INSULATED 600/1000V CABLES Two Core Cables CU/XLPE/PVC/LC/PVC/SWA/PVC 1 Three Core Cables CU/XLPE/PVC/LC/PVC/SWA/PVC 2 Four Core Cables CU/XLPE/PVC/LC/PVC/SWA/PVC
CABLES FOR PHOTOVOLTAIC SOLAR ENERGY INSTALLATIONS FOR CLEAN ENERGY
CABLES FOR PHOTOVOLTAIC SOLAR ENERGY INSTALLATIONS FOR CLEAN ENERGY One Company Connecting The World POWERFUL PRESENCE PRODUCTS PERFORMANCE PEOPLE General Cable has been a wire and cable innovator for
XLPE Land Cable Systems User s Guide. Rev 5
XLPE Land Cable Systems User s Guide Rev 5 CONTENT XLPE Land Cable Systems Introduction... 3 Design, installation and testing... 4 XLPE cables... 4 Cable accessories... 4 Installation of XLPE cable systems...
6 ELECTRICAL PARAMETERS
6 ELECTRICAL PARAMETERS For power, low voltage and medium voltage cables, cross section nominal areas are calculated in taking into account several parameters as: permissible current carrying capacities
EDS 02-0027 11KV TRIPLEX CABLE
THIS IS AN UNCONTROLLED DOCUMENT, THE READER MUST CONFIRM ITS VALIDITY BEFORE USE Document Number: EDS 02-0027 ENGINEERING DESIGN STANDARD EDS 02-0027 11KV TRIPLEX CABLE Network(s): EPN, LPN, SPN Summary:
THE PATHWAY TO POWER HIGH-VOLTAGE CABLES
THE PATHWAY TO POWER HIGH-VOLTAGE CABLES TABLE OF CONTENTS HIGH-VOLTAGE CABLES 3 Advantages of XLPE-insulated cable systems 3 PROPOSAL 4 Cable systems 4 Providing System Solutions 4 Continuous temperature
Fibre optic cables MDIC LSZH
MDIC LSZH MDIC LSZH - Indoor Access Cable. Micro Drop Installation Cable, special Access cable with low bend radius, no waterpeak G.657.A fibres. Ruggedized construction with excellent performance, easy
KNOW YOUR OPTIONS: 230 KV POWER CABLES
KNOW YOUR OPTIONS: 230 KV POWER CABLES 71 CONDUCTOR MATERIAL AND SIZE Conductor material is a matter of both customer preference and required current carrying capacity At 230 kv, copper is most common
Current Ratings. TABLE BEC 107. (Continued) Current ratings for 6350/11000 volts grade PILC/SWA/PVC cable to BS6480/69
Ratings TBLE BEC 107. (Continued) ratings for 60/11000 volts grade PILC/SW/PVC cable to BS64/69 CBLES LID IN IR: The ratings given in the foregoing tables are based on an ambient of C. It is recommended
APPLICATION ORIENTED DESIGN OF CABLES
APPLICATION ORIENTED DESIGN OF CABLES Mrs. Rohini Bhattacharyya, Dubai cables Ltd.P. O. Box 11529,Dubai. [email protected] Mr. Nawaf Ahmad Al Mohaideb Dubai Cables Ltd. P. O. Box 11529, Dubai. [email protected]
Section 5 161 kv Power Cables
Know Your Options: 161 kv Power Cable 61 material and size material is a matter of both customer preference and required current carrying capacity Copper conductor common for larger loads When both copper
Cables, Cable Laying & Accessories Manual
Distribution Business Cables, Cable Laying & Accessories Manual Database ref: File Ref: Title Page & Revision Log For Cables & Access v4 - Nov 2003.doc Manual Name: Cables & Accessories Manual Version
Power and Wiring Cables
1 Single-Core PVC 1X...................... 1: Single-Core PVC/PVC 1Y.................. 1: Flat Twin & Flat Three Core PVC /Y........ 1: Multicore XLPE/LSF/SWA/LSF BS Control Cable.............................
KNOW YOUR OPTIONS: 69 KV XLPE POWER CABLE
Know Your Options: 69 kv XLPE Power Cable 3 material and size material is a matter of both customer preference and required current carrying capacity Copper conductor common for larger loads When both
Network Standard Advice No. 1420C 9/6/2011
Network Standard Advice No. 1420C 9/6/2011 TO: Customers, Service Providers and Ausgrid Staff. Advisory Note on Changes to the Use of 11kV Cable Types. Introduction This Network Standard Advice (NSA) provides
Removal of EP 20 10 00 02 SP High Voltage Cable
TN 018: 2014 Technical Note For queries regarding this document [email protected] www.asa.transport.nsw.gov.au TN 018: 2014 Issued date 12 March 2014 Effective dates 12 March 2014 Subject:
FIRE RESISTANT CABLE CONSTRUCTION OF CABLES
FIRE RESISTANT CABLE In all fire disasters, fire smoke, heat and toxic fumes are the main obstacles to safe evacuation of a building or area. A major contribution towards overcoming these hazards is the
HIGH VOLTAGE XLPE CABLE SYSTEMS. Technical User Guide
HIGH VOLTAGE XLPE CABLE SYSTEMS Technical User Guide Content 1. General information on High Voltage XLPE Cable Systems 1.1. Introduction 1.2. Cable selection process 1.3. Service life 3 3 3 4 2. Cable
XLPE рower cables. 2 Modern solutions for power cables I Estralin HVC
XLPE рower cables...2 Production technology...3 Estralin HVC a pioneer in Russia s XLPE cable production...4 Main types of products and services...5 Markings...6 XLPE cables 6-35 kv...7 Comparative characteristics
VIPERFLEX ELECTRIC CABLE
VIPERFLEX Flexible Low Voltage Electric Cable - 0.6/1kV (Rubber insulated) H07 RN-F & H07 BN-F Single Core 2-Core 2-Core and Earth 3-Core and Earth 4-Core and Earth Multi-Core and Earth H07 RCN-F & H07
Cable Consulting International
Cable Consulting International Brian Gregory BSc, CEng, MIEEE, FIEE Technical Director www.cableconsulting.net Alan Williams BSc, CEng, MIEE Senior Consultant 1 FEASIBILITY STUDY for 500 kv AC UNDERGROUND
Chemical resistance Accidental
Industrial flexible cable, insulation and outer sheath in elastomer Description Application TITANEX flexible cable is intended for installations with moving equipment, electric appliances and for building
Fire retardant IEC 60332-1
300 / 500 V Description Approval Certificates VDE Reg N 7691 Application In dry and moist rooms for light mechanical stresses. Outdoors only when protected. Not in water. As supply and interconnecting
www.ptranscable.com We specialize in low voltage cables including: Stranded Single Cable H07V-R Flexible Single Cable H05V-K
P-trans, meaning power transistor, is a well known cable manufacturer based in Aan - Jordan. The production plant produces all sorts of high quality low tension cables and is a leader in the industry supplying
M. GELDON Brugg Kabel CZ. Ing. D. RÚŽEK PREdistribuce. Switzerland Czech Rep. Czech Rep. Czech Rep., Switzerland Germany
21, rue d Artois, F-75008 PARIS Paper number CIGRE 2012 http : //www.cigre.org 6 characters (to be provided later) Correlation between calculated transmission capacity and actual one D. WALD* Eifelkabel
3.6/6 kv XLPE insulated cables 5. 6/10 kv XLPE insulated cables 15. 8.7/15 kv XLPE insulated cables 25. 12/20 kv XLPE insulated cables 35
CONTENTS INTRODUCTION 1 Cable selection, cable specification, cable services CABLES Constructional data: 3.6/6 kv XLPE insulated cables 5 SECTION 1 6/10 kv XLPE insulated cables 15 SECTION 2 8.7/15 kv
The Quality Connection. BETAflam Fire Resistant Safety Cables
The Quality Connection BETAflam Fire Resistant Safety Cables 2 Contact Consulting and sales Switzerland Phone +41 (0)62 288 82 82 Fax +41 (0)62 288 83 83 [email protected] www.leoni-infrastructure-datacom.com
MEDIUM VOLTAGE POWER CABLES
MEDIUM VOLTAGE POWER CABLES CONTENTS 1 GENERAL INTRODUCTION 4 TECHNICAL INFORMATION 15 25 35 45 Single Core XLPE Insulated PVC Sheathed Cables UNARMOURED CABLES COPPER UNARMOURED CABLES ALUMINUM ALUMINUM
How To Monitor Water Penetration In A Cable Screen
Detection and location of high voltage cable sheath damage with Water Penetration Monitoring*) Purpose of Monitoring System The expected lifetime of high voltage underground cables is more than 40 years,
6-36kV Medium Voltage Underground Power Cables. XLPE insulated cables
6-36kV Medium Voltage Underground Power Cables XLPE insulated cables Cable solutions to ensure the reliability of your energy network 2 With energy as the basis of its development, Nexans, the worldwide
Quality Reliability Innovation. ISO 9001 : 2000 CERTIFIED BY AFAQ No. QUAL / 1997 / 7034 a COPPER TELECOMMUNICATION CABLES
Quality Reliability Innovation ISO : CERTIFIED BY AFAQ No. QUAL / 7 / 7 a COPPER TELECOMMUNICATION CABLES COPPER TELECOMMUNICATION CABLES CONTENTS 7 NOTICE INTRODUCTION QUALITY ASSURANCE RECOMMENDED ORDERING
UGVCL/SP/591/11KV HT AB CABLE
TECHNICAL SPECIFICATION FOR 11KV AERIAL BUNCHED CABLES FOR OVERHEAD LINES (CROSSED LINKED POLYTHENE DRY GAS CURED) 1. SCOPE This specification covers requirements of XLPE insulated, 11 KV Aerial Bunched
HV Submarine Cable Systems Design, Testing and Installation
HV Submarine Cable Systems Design, Testing and Installation CIGRE Ireland Technical Seminar 6 th October 2010 Robert Donaghy Senior Consultant Engineer, ESB International Presentation Overview Applications
VDE-approved PVC-Control Cables
Works photo: HELUKAEL VDE-approved PVC-Control Cables VDE-approved PVC-Control Cables This certification/licency is issued according to the rules of the HAR Agreement, wherein the certification/ licency
ENERGY. TECWATER S1BN8-F 0,6/1 kv. Cable for Water Application
ENERGY TECWATER S1BN8-F 0,6/1 kv Cable for Water Application Technical Data Electrical parameters Thermal parameters Trademark Type designation Specification Approval Application Rated voltage Maximum
LEAD FREE FIREX. Interlock Armored Cables TECK90 and MC Industrial Cables. w w w. n e x a n s e n e r g y. c o m
FIREX Interlock Armored Cables TECK90 and MC Industrial Cables LEAD FREE O V E R 1 8 0 Y E A R S O F E X P E R I E N C E 866-663-9267 w w w. n e x a n s e n e r g y. c o m Interlock Armored Cables Introduction....2
Cable flexibility Flexible. Chemical resistance Accidental
H07RN-F Industrial flexible cable, insulation and outer sheath in elastomer Description pplication H07RN-F flexible cable is intended for installations with moving equipment, electric appliances and for
CAVEL VS80205 MADE IN ITALY 1000 V
0,05 9,00 x 7,20 (Pet) (LSZH) Attached CE01 CE02 Sheath Colour black black red Non-migrating Polyester tape longitudinally overlapped (Pet) 25 x 23 µm Outer sheath of Thermoplastic material - black - halogen-free,
COAX Cables Radio Frequency Cables
COAX Cables Radio Frequency Cables Contents Page Table of contents Pictographs General information Introduction Types and abbreviations Temparature range Construction Characteristics Special constructions
Offshore Transformer Platform. Technical Standard. Energinet.dk. HV, MV, LV and Signal Cables and Cable Routing
Offshore Transformer Platform Technical Standard Energinet.dk HV, MV, LV and Signal Cables and Cable Routing ETS - 03 Rev. 1 Acadre doc. 44858-09 Revision survey Chpt. Description Revision Date Resp. -
Tri-Rated Flexible PVC Equipment Wire
Application: High temperature, flame retardant wire designed for use in the switch control, relay and instrumentation panels of power switchgear and for purposes such as internal connectors in rectifier
ENERGY. TECSUN DUO (PV) Twin Cables for Photovoltaics
ENERGY TECSUN DUO (PV) Twin Cables for Photovoltaics Auswahlkriterien Manufacturer Trademark Approvals Application Prysmian Kabel und Systeme GmbH Kabel- und Leitungswerk Neustadt bei Coburg / Germany
R=Required by Lab S=May be subcontracted IEC SYSTEM FOR CONFORMITY TESTING AND CERTIFICATION OF ELECTRICAL EQUIPMENT COMMITTEE OF TESTING LABORATORIES
IEC SYSTEM FO CONFOMITY TESTING AND CETIFICATION OF ELECTICAL EQUIPMENT COMMITTEE OF TESTING LABOATOIES TESTING AND MEASUING EQUIPMENT/ALLOWED SUBCONTACTING Power cables with extruded insulation and their
HVDC Light Cables. Submarine and land power cables
HV Light Cables Submarine and land s The HV Light s to offshore platform The light and robust HV Light s can be laid with very cost effecient methods HV Light System HV Light is a transmission system in
Fault location on power cables. Fault location on power cables
Fault location on power cables Fault location on power cables Contents: 1. Introduction 2. Construction of power cables 3. Cable faults 01. Introduction Fault location on communication and power cables
PROFIBUS cable. for PROFIBUS-PA and -DP 10/63-6.46 EN
for PROFIBUS-PA and -DP 10/63-6.46 EN CPN 080/CPE 080-Ex PROFIBUS-PA basis cable AWG 18, 0.88 mm 2 Use For fixed installation indoor and outdoor, on racks and in conduits. Application Fieldbus cable for
with coloured cores and overall copper screen UL/CSA... 17
CONTENT Cable Track Cables y SD 200 extremely flexible TPE/PUR data cable with coloured cores for continuous movement..... 6 y S 200 extremely flexible TPE/PUR control cable with numbered cores for continuous
Specializing in the cable business for over 38 years, PT. SUPREME CABLE
Specializing in the cable business for over 38 years, PT. SUPREME CABLE MANUFACTURING & COMMERCE Tbk. (PT. SUCACO Tbk) has grown steadly to become a largest and leading cable manufacturer, with international
Product descriptions and characteristics shown in this content have no legal effect. Nexans China has the right to change product specifications
Power Cable Product descriptions and characteristics shown in this content have no legal effect. Nexans China has the right to change product specifications without prior notice. Any unauthorized dissemination,
INTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 60502-1 Second edition 2004-04 Power cables with extruded insulation and their accessories for rated voltages from 1 kv (U m = 1,2 kv) up to 30 kv (U m = 36 kv) Part 1: Cables
Fire Resistant Cables
109/4 Fire Resistant Cables SR 114H Standard - SR 114E Enhanced BS 5839-1 BS 7629-1 BS 6387 BS 8434-1/2 BS 6425 BS 7622 EN 50200 World-wide recognized high quality cables Firecel SR114 are used in: Data
HIGH- AND EXTRA-HIGH-VOLTAGE GLOBAL CABLE SYSTEM SOLUTIONS Rely On Our Experience... Experience Our Capabilities
HIGH- AND EXTRA-HIGH-VOLTAGE GLOBAL CABLE SYSTEM SOLUTIONS Rely On Our Experience... Experience Our Capabilities RELY ON OUR EXPERIENCE... EXPERIENCE OUR CAPABILITIES For close to half a century, Silec
Festoon 715 P PUR cable for flexible application in festoon systems
CABLES FOR CRANE AND CONVEYOR APPLICATIONS Festoon 715 P PUR cable for flexible application in festoon systems S AB BRÖCKSKES D-VIERSEN Festoon 715 P 1 x 16.0 mm 2 C Marking for Festoon 715 P 07150162:
Global cable expertise for rolling stock
Global cable expertise for rolling stock Global cable expertise for rolling stock Single and multicore Low voltage control cables Jumper cables HV roof cables (25 kv) rubber cables for power needs of locomotives
Temperature Permissible ambient temperature. Weather Resistance to severe weather conditions. Impacts Cable mechanical resistance to impacts
Airfield Cables Issue 10/2003 Piktogramme Temperature Permissible ambient temperature Weather Resistance to severe weather conditions Impacts Cable mechanical resistance to impacts Chemical attacks Resistance
E-Highway2050 WP3 workshop April 15 th, 2014 Brussels
E-Highway2050 WP3 workshop April 15 th, 2014 Brussels High voltage underground and subsea cable technology options for future transmission in Europe Ernesto Zaccone, Chairman Europacable High Voltage Systems
Communication, Signal & Data Cables
Communication, Signal & Data Cables Used for indoor installation and interconnection of transmission, telephone, telegraph and electronic equipment as well as media equipments www.alfanar.com Communication
4 IX D N E P P A Installation methods Current-carrying capacity and voltage drop for cables Reference method IET Wiring Matters
8 Appendix 4 of BS 7671 by Mark Coles Appendix 4, Current-carrying capacity and voltage drop for cables and flexible cords, has seen significant changes with the publishing of BS 7671:2008. This article
The color scheme for the fibers in the cable complies with the Telcordia (formerly Bellcore) specification.
10 Cables The cables referred to below are provided with standard single- and multimode fibers. Other commercially available fibers can be provided on request. The bare fibers are colored in all cases
High Voltage Cable Systems
High Voltage Cable Systems Cables and Accessories up to 550 kv Completing the picture nkt cables part of a world, counting on reliable and available electrical power Today a world without electrical power
Series 8146/5-V37 and Series 8150/5-V37
www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection
TECHNICAL SPECIFICATION OF 11 / 22 KV XLPE POWER CABLE FOR SUB-STATION
GUJARAT ENERGY TRANSMISSION CORPORATION LTD. Sardar Patel Vidyut Bhavan, Race Course, Vadodara 390 007 TECHNICAL SPECIFICATION OF 11 / 22 KV XLPE POWER CABLE FOR SUB-STATION GETCO/E/TS PCBL025/RO DT.07-03-2008
Corporate Profile ROYAL. MODERN ROYAL ELECTRIC Ideal Power Solution MRE ELECTRICAL, INSTRUMENTATION & COMMUNICATION SYSTEMS
Corporate Profile MODERN ROYAL ELECTRIC Ideal Power Solution ROYAL MRE ELECTRICAL, INSTRUMENTATION & COMMUNICATION SYSTEMS MAJOR STOCKIST >>> CATHODIC PROTECTION CABLES >>> LOW VOLTAGE CABLES >>> MEDIUM
SCHEDULE ' A ' TECHNICAL SPECIFICATION FOR SINGLE CORE,UNARMOURED L.T.XLPE POWER CABLE FOR DISTRIBUTION NETWORK IN MAHARASHTRA
SCHEDULE ' A ' TECHNICAL SPECIFICATION FOR SINGLE CORE,UNARMOURED L.T.XLPE POWER CABLE FOR DISTRIBUTION NETWORK IN MAHARASHTRA (SPECIFICATION NO.MM/I/ 1 X C-UA- LTXLPE/2006) MAHARASHTRA STATE ELECTRICITY
ISO 9001 ISO 14001 CABLES AND WIRES CATALOGUE 2008
ISO 9001 ISO 14001 CABLES AND WIRES CATALOGUE 2008 INTRODUCTION... 4 CHAPTER I SINGLE CORE NON-SHEATHED CABLES H05V-U, H05V-R, H05V-K... 6 H05V2-U, H05V2-R, H05V2-K... 7 H07V-U, H07V-R, H07V-K... 8 H07V2-U,
Standard Buccaneer - Ethernet
IP6 rated compliant PUR jacket on cable Shielded system shielded coupler Shroud on RJ45 Screw coupling Rewireable flex connector PCB mounted panel connector IDC termination panel connector Earth lead version
ECS 02-0019 INSTALLATION OF UNDERGROUND CABLES - LV TO 132KV
THIS IS AN UNCONTROLLED DOCUMENT, THE READER MUST CONFIRM ITS VALIDITY BEFORE USE Document Number: ECS 02-0019 ENGINEERING CONSTRUCTION STANDARD ECS 02-0019 INSTALLATION OF UNDERGROUND CABLES - LV TO 132KV
Effects of the circulating sheath currents in the magnetic field generated by an underground power line
Effects of the circulating sheath currents in the magnetic field generated by an underground power line J.R. Riba Ruiz 1, X. Alabern Morera 2 1 Department d'enginyeria Elèctrica, UPC EUETII-"L'Escola d'adoberia"
450-750 VOLTS - Copper conductor PVC insulated SSA 1320, IEC 60227 & BS 6004 HO 7V - U With Solid Conductor - TYPE 60227 IEC 01. Insulation Thickness
450 50 VOLTS Copper conductor PVC insulated SSA 320, IEC 6022 & BS 6004 HO V U With Solid TYPE 6022 IEC 0 For internal wiring equipment rated voltage up to 000 V AC and up to 50 V to earth. Catalogue Number
100% EMI Emission Containment
100% EMI Emission Containment Designed for Longer Service Life Highly Flexible for Easier Handling and Faster Installation Authorized Distributor Industrial VFD Cables Index n Variable Frequency Drive
Real Time Monitoring of Power Cables by Fibre Optic Technologies Tests, Applications and Outlook
Real Time Monitoring of Power Cables by Fibre Optic Technologies Tests, Applications and Outlook LUTON Marie-Hélène SAGEM SA, Activité Câbles Rue de Varennes Prolongée 77876 Montereau Cedex France Phone
Gulf Cable & Electrical Ind. Co.
CONTENTS INTRODUCTION PRODUCT RANGE I PRODUCT DATA TABLES Irrigation 1 Coaxial s for T.V/ Satellite Antenna etc 2 Data Transmission s - 4 pair 24 AWG 3 TELEPHONE CABLES Telephone cables CCP-LAP & CCP-LAP-SS
Flexible Control Cables
Works photo: KUKA Flexible Control Cables A Flexible Control Cables Since generations people try to build machines and plants which shall take on different functions. To raise, sink, slide, drill, transport
Respecting the environment
MAIN FEATURE CHAPTER I RESEARCH WITH AN EYE ON THE FUTURE Respecting the environment Low power losses and a lesser visual impact on the landscape make Gas-Insulated Lines (GIL) a very environmentally friendly
Sizing conductors and selecting protection devices
Sizing conductors and selecting protection devices 04 PowEr guide 2009 / BOOk 04 INTRO Careful selection of the sizes of the conductors in wiring systems and the characteristics of protection devices will
GOWN. Central Loose Tube Cables Outdoor, Steel Wire Armor (SWA) A-DQ(ZN)2YB2Y Full Rodent Protection. Ordering Information.
GOWN Central Loose Tube Cables Outdoor, Steel Wire Armor (SWA) A-DQ(ZN)2YB2Y Full Rodent Protection Ordering Information Belden European Part Numbers Fibre type / count 2 4 6 8 12 16 24 62.5/125-OM1 GOWN102
Airdac CNE and SNE, 600/1000V, Polyethylene Sheath, SANS 1507, NRS 063 & NRS 017
Airdac CNE and SNE, 600/1000V, Polyethylene Sheath, SANS 1507, NRS 063 & NRS 017 Conductor: Hard Drawn Copper Conductor Class 2 Insulation: LV-XLPE Phase Color Code(SNE): Red, Black & Bare Copper Phase
OPTICAL FIBER CABLES
OPTICAL FIBER CABLES CONTENTS INTRODUCTION QUALITY ASSURANCE RECOMMENDED ORDERING PARAMETERS GENERALITIES :. Advantage. General Description.. Construction.. Principle TYPICAL SPECIFICATIONS OF OPTICAL
Two different types of cables are used in primary airfield lighting circuits: - unshielded cables and - shielded cables
Two different types of cables are used in primary airfield lighting circuits: - unshielded cables and - shielded cables Classically both cables have a single AWG 8 copper conductor or a cross section of
PROFIBUS cable. PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications
Data Sheet 10/63-6.47-EN Rev. D PROFIBUS cable PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications PROFIBUS PA cables Non-Ex (Hazardous) applications Ex (Hazardous) applications
TECHNICAL SPECIFICATIONS OF 66 KV 1C 300 SQ.MM. XLPE POWER CABLE FOR UNDER GROUND LINE
GUJARAT ENERGY TRANSMISSION CORPORATION LTD. Sardar Patel Vidyut Bhavan, Race Course, Vadodara: 390 007 TECHNICAL SPECIFICATIONS OF 66 KV 1C 300 SQ.MM. XLPE POWER CABLE FOR UNDER GROUND LINE GETCO/E /TS
WWW.CABLEJOINTS.CO.UK THORNE & DERRICK UK TEL 0044 191 490 1547 FAX 0044 477 5371 TEL 0044 117 977 4647 FAX 0044 977 5582 WWW.THORNEANDDERRICK.CO.
able leats Section 6 able leats for Power Transmission ables Glass reinforced composite cable cleats general information type able cleat U type able cleat (channel mounted) T type able cleat (trefoil configuration)
Modeling of Transmission Lines
Modeling of Transmission Lines Electric Power Transmission The electric energy produced at generating stations is transported over high-voltage transmission lines to utilization points. The trend toward
International Electrotechnical Commission Standards
International Electrotechnical Commission Standards Standard IEC 60028 IEC 60038 IEC 60050-461 IEC 60055-1 IEC 60055-2 IEC 60092-101 IEC 60092-350 IEC 60092-351 IEC 60092-352 IEC 60092-353 IEC 60092-354
TECHNICAL SPECIFICATIONS OF 66 KV 1C 630 SQ.MM. XLPE POWER CABLE FOR UNDER GROUND LINE
GUJARAT ENERGY TRANSMISSION CORPORATION LTD. Sardar Patel Vidyut Bhavan, Race Course, Vadodara: 390 007 TECHNICAL SPECIFICATIONS OF 66 KV 1C 630 SQ.MM. XLPE POWER CABLE FOR UNDER GROUND LINE GETCO/E/TS
BETAtrans. Cables and Systems for Rolling Stock. Edition 2006
BETAtrans Cables and Systems for Rolling Stock. Edition 2006 Info Consulting and Sales By Phone To ask for Information or to place an order please use the following number: +49 (0)9172-6844-11 By Fax For
SUITABILITY OF DIFFERENT TEST VOLTAGES FOR ON-SITE TESTING OF XLPE CABLE SYSTEMS
SUITABILITY OF DIFFERENT TEST VOLTAGES FOR ON-SITE TESTING OF XLPE CABLE SYSTEMS Michael Hensel HIGHVOLT Prüftechnik Dresden GmbH 2 3 Content 1 Introduction Test parameters and their significance Differences
Stephen G. Whitley, Senior Vice President & Chief Operating Officer
Peter T. Brandien Vice President, System Operations To: Stephen G. Whitley, Senior Vice President & Chief Operating Officer From: Peter T. Brandien Re: Discussion of Cable Technologies Under Evaluation
Instrumentation Cable...14-17. Power Cable...2-11. Assembly Solutions...32
Severe Cold Durability Exceeds CSA Cold Bend / Cold Impact (-0 C/-35 C) Drilling Mud Resistant Flame Retardant Certified to IEC 9-3 (33-3A) and IEEE 580 Oil Resistant Assemblies...3-33 Ester Based Mud
Outside Telephone Cable
Outside Telephone Cable Filled Core. Moisture Barrier. Description Soft copper wires insulated with high density polyethylene, foam skin or solid. Filled core, conformed by groups of pairs or by unit of
AORC Technical meeting 2014
http : //www.cigre.org B1-1055 AORC Technical meeting 2014 220 kv Long Distance Underground HVAC Cable Circuit NAVEED RAHMAN Nexans Olex Melbourne, Australia SUMMARY In 2009, the Victorian state government
Handling and Installation of Cables up to and including 33kV
1 SCOPE This document details ScottishPower EnergyNetworks (SPEN) technical requirements for the handling and installation of power cables up to onto the Company network. 2 ISSUE RECORD This is a maintained
CABLE ACCESSORIES 110-220 kv
CABLE ACCESSORIES 110-220 kv Termination 110 kv Technical description Termination MKB 126 / 145 with composite type insulator uses for cable line joints with other elements of power-supply systems. Termination
Ampacity simulation of a high voltage cable to connecting off shore wind farms
Ampacity simulation of a high voltage cable to connecting off shore wind farms Eva Pelster 1, Dr. David Wenger 1 1 Wenger Engineering GmbH, Einsteinstr. 55, 89077 Ulm, [email protected] Abstract:
FIBRA OPTICA INTERIOR/EXTERIOR TIGHT BUFFER
FIBRA OPTICA INTERIOR/EXTERIOR TIGHT BUFFER 1. Applications - Be suitable for the cable of communication,communication device pigtail and the movable connection wire jumper wire - Short and medium distance,
Building Cables and Wires
Building Cables and Wires 4 Introduction alfanar is equipped with state-of-the-art manufacturing facilities such as latest machineries, instrumentation, quality control and testing laboratory, etc., for