1 PVC Types Tri-Rated Single-Core : H0V-K (1X) & H0V-K (01X) Single-Core... : DEF 1-1 Equipment Wires : PVC Insulated and Sheathed Flexible Multicore (1*Y) : PVC Insulated Heat Resistant Flexible Multicore (0*Y) : UL Style Hook Up Wires :1 Automotive Wire - SXL/GXL/TXL :1 Automotive Wire FLY Standard Wall :1 Automotive Wire FLRY-B Thin Wall :0 Automotive Extra Flexible Battery/Starter Cable.. :1 Automotive FLYY-F Thin Wall Flat Twin : Automotive FLRYY Thin Wall Round : Automotive FLYZ Twin Speaker Cable : Rubber Types H0RN-F : EPR Insulated, HOFR Sheathed up to.mm.... :0 EPR Insulated, HOFR Sheathed mm and above.. : Welding Cable to BS : Coil Lead to BS : LSZH Types H0Z-K (1B) & H0Z-K (01B) Single-Core.. : LSZH Insulated and Sheathed Flexible Multicore.. :0 Technical Specifications Current Ratings for Extra Flexible Battery : Current Ratings for Thin Wall & Standard Wall Automotive Wires : Other Types :

2 1 Tri-Rated C 00/00 V Application For the internal wiring appliances and also the wiring of switch, control, metering and instrument panels of power switchgear. 1 1 Specifications In accordance with BS1 Type CK Conforms to UL subject Appliance Wiring Material (AWM) for styles 1,, 1 and 1 as applicable. RoHS Compliant Canadian Standards Association (CSA) approved. Complies with standard C. No.1, Type TEW <HAR> Approved to H0V-K, depending on manufacturer s: Flexible Class conductors to BS EN 0 Insulation: PVC insulation Normal colours available see page : Flame retardant to BS EN 0-1- and VW-1 Temperature Rating: BS1 specifies a maximum continuous conductor operating temperature of 0 C, and for limited use up to C. UL and CSA rated C Voltage Rating: 00/00 V (BS), 00 V (UL & CSA) 0/0 V (HAR)

3 Anixter Number Area Tri-Rated C 00/00 V ## = colour, -01 = white, -0 = black, -0 = red, -0 = green, -0 = yellow, -0 = blue, -0 = brown, -0 = orange, -0 = grey, - = violet, -1 = pink, -0 = green/yellow. etc. Other colours available upon request. For more technical information see page :0. Stranding mm #/mm mm kg/km O/D Approximate Weight UL Style Number TRI-000-## 0. 1/ TRI-000-## 0. / TRI-00-## 1.0 / TRI-001-## 1. 0/0.. 1 TRI-00-##. 0/0.. 1 TRI-000-##.0 / TRI-000-##.0 / TRI-00-## 0/0.. 1 TRI-010-## 1 1/ TRI-00-## 1/ TRI-00-## / TRI-000-## 0 / TRI-000-## 0 0/ TRI-00-## / TRI-0-## 0/

4 1 Single-Core PVC Insulated H0V-K & H0V-K 0 C 00/00 V and 0/0 V Application For fixed protected installation inside appliances and in/on light fittings, where increased flexibility is required to assist installation. 1 Specifications In accordance with Cenelec code H0V-K1 and H0V-K1 RoHS Compliant s: Flexible Class copper conductors to BS EN 0 Insulation: PVC Insulation Type TI.1 to BS EN 0- Flame retardant to BS EN 0-1- Temperature Rating: 0 C maximum conductor operating temperature Voltage Rating: 00/00 V, 0/0 V

5 Anixter Number Cenelec Code Area Single-Core PVC Insulated H0V-K & H0V-K 0 C 00/00 V and 0/0 V Stranding Insulation Thickness ## = colour, -01 = white, -0 = black, -0 = red, -0 = green, -0 = yellow, -0 = blue, -0 = brown, -0 = orange, -0 = grey, - = violet, -1 = pink, -0 = green/yellow. etc. Other colours available upon request. For further technical information refer to pages : (H0V-K) and : (H0V-K). Maximum O/D Approximate Weight mm #/mm mm mm kg/km HCN-K1-A-## H0V-K1 0. 1/ HCN-K1-B-## H0V-K1 0. / HCN-K1-C-## H0V-K1 1.0 / HDN-K1-D-## H0V-K1 1. 0/ HDN-K1-E-## H0V-K1. 0/ HDN-K1-F-## H0V-K1.0 / HDN-K1-G-## H0V-K1.0 / HDN-K1-H-## H0V-K1 0/ HDN-K1-I-## H0V-K1 1 1/ HDN-K1-J-## H0V-K1 1/ HDN-K1-K-## H0V-K1 / HDN-K1-L-## H0V-K1 0 / HDN-K1-M-## H0V-K1 0 0/ HDN-K1-N-## H0V-K1 / HDN-K1-P-## H0V-K1 0/ HDN-K1-Q-## H0V-K1 10 / HDN-K1-R-## H0V-K1 1 / HDN-K1-S-## H0V-K1 0 /

6 1 DEF 1-1 Equipment Wires Application For internal wiring of electronic and other equipment. 1 Specification In accordance with DEF 1-1 Part and BS0 Part RoHS Compliant s: Tinned copper conductors to BS EN 0 Insulation: PVC insulation Type to BS (Types 1 and equipment wires) - PVC insulation Type TI.1 to BS EN 0- (Types,,,, equipment wires) Normal colours available: red, blue, green, yellow, black, white, brown, violet, orange, grey, pink Temperature Rating: C maximum conductor operating temperature Voltage Rating: 0, 00, 100 V a.c. and 000 V d.c

7 Anixter Number Area Stranding Insulation Thickness DEF 1-1 Equipment Wires ## = colour, -0 = black, -0 = red, -0 = green, -0 = yellow, -0 = blue, -0 = brown, -0 = grey, -0 = green/yellow. Other colours available upon request. PVC hard grade and general purpose, available screened and PVC sheathed. For further technical information see page :. For LFH equipment wire refer to DEF 1-1 Part 1 wires in Section. Minimum O/D Maximum O/D Approximate Weight mm #/mm mm mm mm kg/km Type 1 - PVC hard grade working temp - 1ºC to +ºC 0 Vrms A-SO1-1-## 0.1 1/ A-SO1--## 0. 1/ A-SO1--## 0. / Type - PVC hard grade working temp - 1ºC to +ºC 00 Vrms A-SO1-01-## 0.1 1/ A-SO1-0-## 0. 1/ A-SO1--## 0. 1/ A-SO1-0-## 0. / A-SO1-0-## 0.0 1/ A-SO1--## 0. / Type - PVC general purpose working temp - 0ºC to +ºC 100 Vrms A-SO1-0-## 0. 1/ A-SO1--## / A-SO1-00-## 0.0 1/ A-SO1-0-## 0. / A-SO1-0-## 1.00 / A-SO1-0-##.00 / Type - PVC hard grade working temp - 0ºC to +ºC 000 V d.c. A-SO1-0-## 0.0 1/

8 1 PVC Insulated and Sheathed Flexible Cords 0 C 00/00 V 1*Y Application For external supply connection of portable appliances for medium duties in domestic or office environments. * denotes number of cores. 1 1 Specifications In accordance with BS00 (up to.sqmm) and BS1 (sqmm only) and Cenelec code H0VV-F s: Flexible Class conductors to BS EN 0 Insulation: PVC insulation Type TI. to BS EN 0- Core Identification: core - blue, brown core - green/yellow, blue, brown core - green/yellow, brown, black, grey core - green/yellow, brown, black, grey, blue Sheath: PVC sheath Type TM. to BS EN 0--1 (black or white) Flame retardant to BS EN 0-1- Temperature Rating: 0 C maximum conductor operating temperature Voltage Rating: 00/00 V

9 Anixter Number Twin Core Type 1Y Cenelec Code Area ## = sheath colour, -01 = white, -0 = black. Other colours available upon request. * Not a harmonised type (National Type). For further technical information see page :. Arctic grades also available. Details upon request. PVC Insulated and Sheathed Flexible Cords 0 C 00/00 V 1*Y Stranding Insulation Thickness Minimum O/D Maximum O/D Approximate Cable Weight mm #/mm mm mm mm kg/km 1Y-000-## H0VV-F 0. / Y-00-## H0VV-F 1.0 / Y-001*-## / Y-001-## H0VV-F 1. 0/ Y-00-## H0VV-F. 0/ Y-000-## H0VV-F.0 / Three Core Type 1Y 1Y-000-## H0VV-F 0. / Y-00-## H0VV-F 1.0 / Y-001*-## / Y-001-## H0VV-F 1. 0/ Y-00-## H0VV-F. 0/ Y-000-## H0VV-F.0 / Four Core Type 1Y 1Y-000-## H0VV-F 0. / Y-00-## H0VV-F 1.0 / Y-001-## H0VV-F 1. 0/ Y-00-## H0VV-F. 0/ Y-000-## H0VV-F.0 / Five Core Type 1Y 1Y-000-## H0VV-F 0. / Y-00-## H0VV-F 1.0 / Y-001-## H0VV-F 1. 0/ Y-00-## H0VV-F. 0/ Y-000-## H0VV-F.0 /

10 1 PVC Insulated and Sheathed Heat Resistant Flexible Cords 0 C 00/00 V 0*Y Application For external supply connection of portable or fixed electrical appliances operating in elevated temperature zones. * denotes number of cores. 1 1 Specifications In accordance with BS00 s: Flexible Class conductors to BS EN 0 Insulation: PVC insulation Type TI. to BS EN 0- Core Identification: core - blue, brown core - green/yellow, blue, brown core - green/yellow, brown, black, grey Sheath: PVC sheath Type TM. to BS EN 0--1 (white) Flame retardant to BS EN 0-1- Temperature Rating: 0 C maximum conductor operating temperature Voltage Rating: 00/00 V

11 Anixter Number PVC Insulated and Sheathed Heat Resistant Flexible Cords 0 C 00/00 V 0*Y Area Stranding Insulation Thickness Minimum O/D Maximum O/D Approximate Cable Weight mm #/mm mm mm mm kg/km Twin Core Type 0Y 0Y / Y / Y / Y / Y / Three Core Type 0Y 0Y / Y / Y / Y / Y / Four Core Type 0Y 0Y / Y / Y / Y / Y / For further technical information see page :

12 1 UL Style Single-Core Cables 0/1 Application These wires are used in small equipment or for data transmission up to 00 Volts. These cables are internationally recognised. 1 Specifications s: Flexible tinned copper (class ) Insulation: wall 0.mm Standards: UL 0 UL 1 CSA TR- (0 C) VW-1 Fire Performance: Flame retardant to VW-1 Temperature Rating: - C minimum operating temperature +0 C/ C (0/1) maximum conductor operating temperature Voltage Rating: 00 V Anixter Number Size AWG Stranding #/mm Overall Diameter mm Approximate Weight kg/km UL 0/1 Flexible Tinned s 0-/-## / /-## / /-## / /-## 0 / /1-## 1 1/ /-## 1 / /1-## 1 1/ /-## 1 / /-## /0... ## Insert appropriate suffix for required colour of core: 0 = Black, 1 = Brown, = Red, = Orange, = Yellow, = Green = Blue, = Violet, = Grey, = White, P = Pink, = Green/Yellow Above information may vary depending on manufacturer. Other cable constructions are available on request. 0 1

13 UL Style Single-Core Cables 1 1 Application This range of multi-standard cables is used for wiring in fixed installations of electric and electronic components in switch gear cabinets, up to 00 Volts. These cables are internationally recognised. Specifications s: Flexible tinned copper (class ) Insulation: wall 0.mm Standards: UL 1 CSA TEW C CSA TR- 0 C VW-1 Fire Performance: Flame retardant to VW-1 Temperature Rating: -0 C minimum operating temperature + C maximum conductor operating temperature Voltage Rating: 00 V 1 Anixter Number Size AWG Stranding #/mm Overall Diameter mm Approximate Weight kg/km UL 1 Flexible Tinned s 1-/-## / /-## / /-## 0 / /1-## 1 1/ /-## 1 / /1-## 1 1/ /-## 1 / /-## /0... ## Insert appropriate suffix for required colour of core: 0 = Black, 1 = Brown, = Red, = Orange, = Yellow, = Green = Blue, = Violet, = Grey, = White, P = Pink, = Green/Yellow Above information may vary depending on manufacturer. Other cable constructions are available on request

14 1 UL Style Single-Core Cables 1 Application Designed to be used for internal installations and electronic control devices. These cables are internationally recognised. Specifications s: Flexible tinned copper (class ) Insulation: wall 0.mm (semi-rigid) Standards: UL 1 VW-1 CSA Type T II SR-PVC Fire Performance: Flame retardant to VW-1 Temperature Rating: - C minimum operating temperature +0 C maximum conductor operating temperature Voltage Rating: 00 V Anixter Number Size AWG Stranding #/mm Overall Diameter mm Approximate Weight kg/km UL 1 Tinned Flexible 1-/-## / /-## / /-## 0 / /-## 1 1/ /-## 1 / ## Insert appropriate suffix for required colour of core: 0 = Black, 1 = Brown, = Red, = Orange, = Yellow, = Green = Blue, = Violet, = Grey, = White, P = Pink, = Green/Yellow Above information may vary depending on manufacturer. Other cable constructions are available on request

15 0 1

16 1 Automotive Wire SXL - GXL Application For use in general wiring circuits in vehicles where severe conditions such as oxidation and high temperatures may be present. These wires are approved for use in motor and vehicle engine compartments. Specifications s: Plain stranded copper Insulation: XLPE Standards: SAE J, MIL0-A, MIL0-B, MS-1, MS-00 Fire Performance: Flame retardant to VW-1 Anixter Number Size Overall Diameter Approximate Weight AWG mm kg/km SXL SXL-001-## 0.. SXL-101-## SXL-101-## SXL-101-## 1..1 SXL-1-## SXL-01-##. 1. GXL GXL-001-## 0..1 GXL-101-## 1.. GXL-101-## GXL-101-## 1.. GXL-1-## 1..0 GXL-01-##.. ## Insert appropriate suffix for required colour of core: 0 = Black 1 = Brown = Red = Orange = Yellow = Green = Blue = Violet = Grey = White P = Pink = Green/Yellow Conversion table: See Additional Technical Information on page : and :. Other cable constructions are available on request. Temperature Rating: -1 C minimum operating temperature +1 C maximum conductor operating temperature Voltage: 0 V 0 1

17 Automotive Wire TXL 1 Application For use in general wiring circuits in vehicles where severe conditions such as oxidation and high temperatures may be present. These wires are approved for use in motor and vehicle engine compartments. Specifications s: Plain stranded copper Insulation: XLPE Standards: SAE J, MIL1-A, MS- Fire Performance: Flame retardant to VW-1 Temperature Rating: -1 C minimum operating temperature +1 C maximum conductor operating temperature Voltage: 0 V Anixter Number Size Overall Diameter Approximate Weight TXL AWG mm kg/km TXL-001-## TXL-101-## 1.0. TXL-101-## TXL-101-## TXL-1-## TXL-01-## ## Insert appropriate suffix for required colour of core: 0 = Black 1 = Brown = Red = Orange = Yellow = Green = Blue = Violet = Grey = White P = Pink = Green/Yellow Conversion table: See Additional Technical Information on page : and :. Other cable constructions are available on request

18 1 Automotive Wire FLY - Standard Wall Insulation RoHS Application Standard wall automotive cables are ideal for use in automotive and marine. The wire s lead free, PVC polymer, offers excellent resistance to petrol, chemicals, and abrasion, and in addition is suitable for both low and high temperature applications. N.B. Flexible conductors with cross sections above mm are also suitable as battery cables Specifications In accordance with ISO /BS Pt 1 and meeting LV, BMW 00-, VW 00 s: Flexible Class copper conductors to BS EN 0 with wires conforming to EN 10 for CU-ETP-1 Insulation: PVC insulation Class B to ISO (lead free) Anixter Number Area Stranding Insulation Thickness Flame retardant to BS EN 0-1- Temperature Rating: -0 C to + C (000 hours) Voltage Rating: 0 V d.c, V a.c. (suitable for 1 Volt & Volt systems) Maximum O/D Approximate Weight mm #/mm mm mm kg/km ohm/km AUTO-00MM-## 0. 1/ AUTO-0 MM-## 0. / AUTO-0MM-## 1.0 / AUTO-01MM-## 1. 0/ AUTO-00MM-##.0 / AUTO-0MM-##. 0/ AUTO-00MM-##.0 / Technical current ratings see page :. Maximum d.c. 0 C

19 Anixter Number Area Stranding Insulation Thickness Maximum O/D Approximate Weight mm #/mm mm mm kg/km ohm/km AUTO-0MM-##.0 / AUTO-00MM-##.0 / AUTO-0MM-## 10/ AUTO-10MM-## 1 1/ AUTO-0MM-## 1/ AUTO-0MM-## / AUTO-00MM-## 0 / AUTO-00MM-## 0 0/ AUTO-0MM-## 0/ AUTO-MM-## 0/ ## = colour: 01 = White 0 = Black 0 = Red 0 = Green 0 = Yellow 0 = Blue 0 = Brown 0 = Orange 0 = Grey = Violet 1 = Pink 0 = Green/Yellow Other colours available upon request. Technical current ratings see page :. Automotive Wire FLY - Standard Wall Insulation (continued) Maximum d.c. 0 C

20 1 Automotive Wire FLRY-B - Thin Wall Insulation RoHS Application These thin-wall automotive cables are ideal for use in automotive and marine applications where its reduced insulation thickness and higher current carrying capacity both help to reduce weight and volume in complex wiring harnesses. The wire s lead free, PVC polymer, hard grade insulation, also offers excellent resistance to petrol, chemicals, and abrasion, and in addition is suitable for both low and high temperature applications. Specifications In accordance with ISO and meeting BMW GS 00-1, VW 00,DBL 1/MB 01, Ford WSK 1A-A, LV, MAN 1, Bosch 0, Fiat 1/1, Fiat 1/1 requirements s: Flexible Class copper conductors to BS EN 0 with wires conforming to EN 10 for CU-ETP-1 Anixter Number Area Stranding Insulation Thickness Insulation: PVC insulation Class B to ISO (lead free) Flame retardant BS EN 0-1- Temperature Rating: -0 C + C (000 hours) mobile and fixed installations Voltage: 0 V d.c. (suitable for 1 Volt & Volt systems) O/D Approximate Weight mm #/mm mm mm kg/km ohm/km AUTO-TW00-## 0. 1/ AUTO-TW0-## 0. / AUTO-TW0-## 1.0 / AUTO-TW01-## 1. 0/ AUTO-TW00-##.0 / AUTO-TW0-##. 0/ AUTO-TW00-##.0 / AUTO-TW00-##.0 / AUTO-TW0-##. / AUTO-TW00-##.0 / AUTO-TW0-##. / AUTO-TW0-## 10/ AUTO-TW10-## 1 1/ AUTO-TW0-## 1/ ## = colour: 01 = White 0 = Black 0 = Red 0 = Green 0 = Yellow 0 = Blue 0 = Brown 0 = Orange 0 = Grey = Violet 1 = Pink 0 = Green/Yellow Other colours available upon request. Technical current ratings see page :. Maximum d.c. 0 C 0 0

21 Automotive Wire Extra-Flexible Battery/Starter Cable 1 RoHS Application These extra flexible automotive cables are ideal for use in automotive and marine applications, range of extra flexible battery/ welding cable, using fine stranded copper conductors, Class, bare copper rope stranded, with soft PVC insulation, resistant to abrasion, moisture, petrol/diesel, oil and diluted acids. Specifications Generally in accordance with ISO s: Flexible Class copper conductors to BS EN 0 Insulation: Flexible grade PVC (chromium, cadmium, lead and mercury free) Flame retardant to BS EN 0-1- Temperature Rating: -0 C +0 C fixed installation, + C +0 C mobile installation Voltage Rating: 0/0 V, 00/00 V fixed and protected installation Anixter Number Area Stranding Insulation Thickness O/D Approximate Weight mm #/mm mm mm kg/km ohm/km BATTF-0MM-## 0 / BATTF-MM-## / BATTF-MM-## / BATTF-0MM-## 0 / BATTF-0MM-## 0 / BATTF-0MM-## 0 0/ BATTF-0MM-## 0 00/ BATTF-MM-## 1/ BATTF-MM-## 1/ BATTF-10MM-## 10 0/ ## = colour: 01 = White 0 = Black 0 = Red 0 = Green 0 = Yellow 0 = Blue 0 = Brown 0 = Orange 0 = Grey = Violet 1 = Pink 0 = Green/Yellow Other colours available upon request. Technical current ratings see page :. Maximum d.c. 0 C

22 1 Flexible Cables & Cords Automotive Wire FLYYF - Thin Wall Insulation Flat Cable RoHS Application Two core flat PVC cable with thin wall automotive wire, ideal for use in automotive and marine applications where its reduced insulation thickness and higher current carrying capacity both help to reduce weight and volume in complex wiring harnesses. The wire s lead free, PVC polymer, hard grade insulation, also offers excellent resistance to petrol, chemicals, and abrasion, with a low temperature rating -0 C and high rating +0 C. Specifications In accordance with ISO s: Flexible class copper conductors to BS EN 0 with wires conforming to EN 10 for CU-ETP-1 Insulation: PVC insulation Class B to ISO (lead free) Core Identification: core - red, black or white, black Outer Sheath: Black, white, red or green PVC sheath Class B to ISO (lead free) Anixter Number Insulation Colours Area Stranding Flame retardant to BS EN 0-1- Temperature Rating: -0 C + C (000 hours) mobile and fixed installations Voltage Rating: 0 V d.c. (suitable for 1 Volt & Volt systems) Insulation Thickness O/D Approximate Weight mm #/mm mm mm kg/km ohm/km AUTO-C-TW1MM-##F-RB Red, Black 1.0 1/ x.0 1. AUTO-C-TW1MM-##F-WB White, Black 1.0 1/ x.0 1. AUTO-C-TW1MM-##F-RB Red, Black 1. 1/ x. 1. AUTO-C-TW1MM-##F-WB White, Black 1. 1/ x. 1. AUTO-C-TWMM-##F-RB Red, Black.0 / x.. AUTO-C-TWMM-##F-WB White, Black.0 / x.. AUTO-C-TWMM-##F-RB Red, Black. / x..0 AUTO-C-TWMM-##F-RB White, Black. / x..0 AUTO-C-TWMM-##F-RB Red, Black.0 / x..1 AUTO-C-TWMM-##F-RB White, Black.0 / x..1 ## = sheath colour: 01 = White 0 = Black 0 = Red 0 = Green Maximum d.c. 0 C 0

23 . Automotive Wire FLRYY - Thin Wall Insulation Round Cable 1 RoHS Application Multicore round PVC cable with thin wall automotive wire, ideal for use in automotive and marine applications where its reduced insulation thickness and higher current carrying capacity both help to reduce weight and volume in complex wiring harnesses. The wire s lead free, PVC polymer, hard grade insulation, also offers excellent resistance to petrol, chemicals, and abrasion, with a low temperature rating -0 C and high rating + C. Specifications In accordance with ISO s: Flexible Class copper conductors to BS EN 0 with wires conforming to EN 10 for CU-ETP-1 Insulation: PVC insulation Class B to ISO (lead free) Core Identification: core - red, black, green core - red, black, green, white core - brown, green, red, white, yellow core - black, red, green, yellow, brown, blue, white. core - red, brown, green, yellow, blue, black, purple ( x 1.0mm ), white (.0mm ) Anixter Number Number of Cores Area Stranding Outer Sheath: Black PVC sheath Class B to ISO (lead free) Flame retardant to BS EN 0-1- Temperature Rating: -0 C + C (000 hours) mobile and fixed installations Voltage Rating: 0 V d.c. (suitable for 1 Volt & Volt systems) Insulation Thickness O/D Approximate Weight mm #/mm mm mm kg/km ohm/km AUTO-C-TW1MM / AUTO-C-TWMM-0.0 / AUTO-C-TW1MM / AUTO-C-TW1MM / AUTO-C-TW1MM / AUTO-C-TW1MM / AUTO-C-COMPOSITE (C).0 (1C) /0. /0. 0. (1.0sqmm) 0. (.0sqmm) Maximum d.c. 0 C (1.0sqmm). (.0sqmm)

24 1 Automotive Wire FLYZ - Twin Speaker Cable RoHS Application A range of flexible, two core figure speaker cable. With polarity line indicator along one core to indicate the positive tracer, these are ideal for auto/marine loudspeaker connection. Specifications In accordance with ISO s: Flexible class copper conductors to BS EN 0 with wires conforming to EN 10 for CU-ETP-1 Insulation: PVC insulation Class B to ISO (lead free) Figure construction, available in following colours:- black-black/white, black-black/red, black-black/blue and transparent with coloured tracer Anixter Number Colour Black- Area Stranding Flame retardant to BS EN 0-1- Temperature Rating: -0 C + C (000 hours) mobile and fixed installations Voltage Rating: 0 V d.c. (suitable for 1 Volt & Volt systems) Insulation Thickness O/D Approximate Weight mm #/mm mm mm kg/km ohm/km SPC1/0./BW-P0 Black/White 0. 1/ x SPC/0.BR-P0 Black/Red 0. / x.. SPC/0.BBU-P0 Black/Blue 1.0 / x.0 1. SPC1/0.BW-P0 Black/White 1. 1/ x SPC/0.BW-P0 Black/White. / x SPC/0./BW-P0 Black/White. / x Maximum d.c. 0 C

25 0

26 1 H0RN-F 0 C 0/0 V Application For mains supply or extension leads for portable or fixed equipment operating indoors or outdoors (domestic or industrial) under conditions of frequent handling trailing or flexing. Incorporates heavy duty OFR (Oil resisting Flame Retardant) outer sheath Specifications In accordance with Cenelec code H0RN-F s: Flexible Class plain copper conductors to BS EN 0 Insulation: Rubber insulation Type EI. to BS Core Identification: core - blue, brown core - green/yellow, blue, brown core - green/yellow, brown, black, grey core - green/yellow, brown, black, grey, blue Outer Sheath: Black PCP outer sheath Type EM. to BS Flame retardant to BS EN 0-1- Temperature Rating: 0 C maximum conductor operating temperature Voltage Rating: 0/0 V For further technical information see page : (up to.sqmm conductor size) and : (.0sqmm and above)

27 Anixter Number Single-Core Type Cenelec Code Area Stranding Insulation Thickness H0RN-F 0 C 0/0 V Minimum O/D Maximum O/D Approximate Cable Weight mm #/mm mm mm mm kg/km H0RNF-1C-001 H0RN-F1 1. 0/ H0RNF-1C-00 H0RN-F1. 0/ H0RNF-1C-000 H0RN-F1.0 / H0RNF-1C-000 H0RN-F1.0 / H0RNF-1C-00 H0RN-F1 0/ H0RNF-1C-010 H0RN-F1 1 1/ H0RNF-1C-00 H0RN-F1 1/ H0RNF-1C-00 H0RN-F1 / H0RNF-1C-000 H0RN-F1 0 / H0RNF-1C-000 H0RN-F1 0 0/ H0RNF-1C-00 H0RN-F1 / H0RNF-1C-0 H0RN-F1 0/ H0RNF-1C-100 H0RN-F1 10 / H0RNF-1C-10 H0RN-F1 1 / H0RNF-1C-00 H0RN-F1 0 / H0RNF-1C-000 H0RN-F1 00 1/ H0RNF-1C-000 H0RN-F / H0RNF-1C-000 H0RN-F1 00 1/ Two Core Type H0RNF-C-00 H0RN-F 1.0 / H0RNF-C-001 H0RN-F 1. 0/ H0RNF-C-00 H0RN-F. 0/ H0RNF-C-000 H0RN-F.0 / H0RNF-C-000 H0RN-F.0 / H0RNF-C-00 H0RN-F 0/ H0RNF-C-010 H0RN-F 1 1/ H0RNF-C-00 H0RN-F 1/

28 H0RN-F 0 C 0/0 V Anixter Number Three Core Type Cenelec Code Area Stranding Insulation Thickness Minimum O/D Maximum O/D Approximate Cable Weight mm #/mm mm mm mm kg/km H0RNF-C-00 H0RN-F 1.0 / H0RNF-C-001 H0RN-F 1. 0/ H0RNF-C-00 H0RN-F. 0/ H0RNF-C-000 H0RN-F.0 / H0RNF-C-000 H0RN-F.0 / H0RNF-C-00 H0RN-F 0/ H0RNF-C-010 H0RN-F 1 1/ H0RNF-C-00 H0RN-F 1/ H0RNF-C-00 H0RN-F / H0RNF-C-000 H0RN-F 0 / H0RNF-C-000 H0RN-F 0 0/ H0RNF-C-00 H0RN-F / H0RNF-C-0 H0RN-F 0/ H0RNF-C-100 H0RN-F 10 / H0RNF-C-10 H0RN-F 1 / H0RNF-C-00 H0RN-F 0 / H0RNF-C-000 H0RN-F 00 1/ Four Core Type H0RNF-C-00 H0RN-F 1.0 / H0RNF-C-001 H0RN-F 1. 0/ H0RNF-C-00 H0RN-F. 0/ H0RNF-C-000 H0RN-F.0 / H0RNF-C-000 H0RN-F.0 / H0RNF-C-00 H0RN-F 0/ H0RNF-C-010 H0RN-F 1 1/ H0RNF-C-00 H0RN-F 1/ H0RNF-C-00 H0RN-F / H0RNF-C-000 H0RN-F 0 / H0RNF-C-000 H0RN-F 0 0/ H0RNF-C-00 H0RN-F / H0RNF-C-0 H0RN-F 0/ H0RNF-C-100 H0RN-F 10 / H0RNF-C-10 H0RN-F 1 / H0RNF-C-00 H0RN-F 0 / H0RNF-C-000 H0RN-F 00 1/

29 Anixter Number Five Core Type Cenelec Code Area Stranding Insulation Thickness Minimum O/D Maximum O/D Approximate Cable Weight mm #/mm mm mm mm kg/km H0RNF-C-00 H0RN-F 1.0 / H0RNF-C-001 H0RN-F 1. 0/ H0RNF-C-00 H0RN-F. 0/ H0RNF-C-000 H0RN-F.0 / H0RNF-C-000 H0RN-F.0 / H0RNF-C-00 H0RN-F 0/ H0RNF-C-010 H0RN-F 1 1/ H0RNF-C-00 H0RN-F 1/ Seven Core Type H0RNF-C-001 H0RN-F 1. 0/ H0RNF-C-00 H0RN-F. 0/ Twelve Core Type H0RN-F 0 C 0/0 V H0RNF-1C-001 H0RN-F1 1. 0/ H0RNF-1C-00 H0RN-F1. 0/

30 1 Rubber Flexible up to.mm EPR Insulated, HOFR Sheathed 0 C 00/00 V 1*TQ Application For mains supply or extension lead for portable or fixed equipment operating in high temperature zones. Particularly suitable for applications where contamination by oil and grease may occur. *denotes number of cores Specifications In accordance with BS00 and Cenelec Code H0BN-F s: Flexible Class tinned copper conductors to BS EN 0 Insulation: EPR insulation Type EI. to BS Core Identification: core - blue, brown core - green/yellow, blue, brown core - green/yellow, brown, black, grey core - green/yellow, brown, black, grey, blue Sheath: H.O.F.R sheath Type EM. to BS EN 0--1 (black or white) Flame retardant to BS EN 0-1- Temperature Rating: 0 C maximum conductor operating temperature Voltage Rating: 00/00 V

31 Rubber Flexible up to.mm EPR Insulated, HOFR Sheathed 0 C 00/00 V 1*TQ Anixter Number Twin Core Type 1TQ Area ## For white sheath use suffix -01 For black sheath use suffix -0 Stranding Insulation Thickness H0BN-F only valid in sizes 0. and 1.0sqmm in Two and Three core only. For further technical information see page :. Minimum O/D Maximum O/D Approximate Cable Weight mm #/mm mm mm mm kg/km 1TQ-000-## 0. 1/ TQ-000-## 0. / TQ-00-## 1.0 / TQ-001-## 1. 0/ TQ-00-##. 0/ Three Core Type 1TQ 1TQ-000-## 0. 1/ TQ-000-## 0. / TQ-00-## 1.0 / TQ-001-## 1. 0/ TQ-00-##. 0/ Four Core Type 1TQ 1TQ-000-## 0. / TQ-00-## 1.0 / TQ-001-## 1. 0/ TQ-00-##. 0/ Five Core Type 1TQ 1TQ-000-## 0. / TQ-00-## 1.0 / TQ-001-## 1. 0/ TQ-00-##. 0/

32 1 EPR Insulated, Heavy Duty HOFR Sheathed Flexible Cables 0 C 0/0 V *TQ Application For power/lighting services and mains supply or extension leads in situations requiring frequent handling, trailing and flexing applications. Incorporates heavy duty HOFR (Heat resisting Oil resisting Flame Retardant) outer sheath. *denotes number of cores Specifications In accordance with BS1 and Cenelec code H0BN-F s: Flexible Class tinned copper conductors to BS EN 0 Insulation: EPR insulation Type EI. to BS Core Identification: core - blue, brown core - green/yellow, blue, brown core - green/yellow, brown, black, grey core - green/yellow, brown, black, grey, blue Sheath: Black heavy duty HOFR Sheath Type EM. to BS EN 0--1 Flame retardant to BS EN 0-1- Temperature Rating: 0 C maximum conductor operating temperature Voltage Rating: 0/0 V For further technical information see page :. (Single-Core), and : (Multicore)

33 Anixter Number EPR Insulated, Heavy Duty HOFR Sheathed Flexible Cables C 0/0 V *TQ Area Stranding Insulation Thickness Minimum O/D Maximum O/D Approximate Cable Weight mm #/mm mm mm mm kg/km Single-Core Type 1TQ 1TQ / TQ / TQ-00 0/ TQ / TQ-00 1/ TQ-00 / TQ / TQ / TQ-00 / TQ-0 0/ TQ / TQ-10 1 / TQ-00 0 / TQ / TQ / TQ / TQ-00 0 / Two Core Type TQ TQ / TQ / TQ-00 0/ TQ / TQ-00 1/ Three Core Type TQ TQ / TQ / TQ-00 0/ TQ / TQ-00 1/ TQ-00 / TQ / TQ / TQ-00 / TQ-0 0/ TQ / TQ-10 1 / TQ-00 0 / TQ / Continued overleaf

34 1 1 1 EPR Insulated, Heavy Duty HOFR Sheathed Flexible Cables C 0/0 V *TQ (continued) Anixter Number Area Stranding Insulation Thickness Minimum O/D Maximum O/D Approximate Cable Weight mm #/mm mm mm mm kg/km Four Core Type TQ TQ / TQ / TQ-00 0/ TQ / TQ-00 1/ TQ-00 / TQ / TQ / TQ-00 / TQ-0 0/ TQ / TQ-10 1 / TQ-00 0 / Five Core Type TQ TQ / TQ / TQ-00 0/ TQ / TQ-00 1/

35 Welding Cables - Rubber Insulated C 0 V 1 Application Primary use is for the secondary (high current) connection to automatic or hand-held metal arc welding electrodes. May also be used for non-welding applications such as earth/return leads, flexible tails on power supplies, busbar connections, etc. Specification In accordance with BS Part Flexible Class copper (plain/tinned) conductors to BS EN 0 Paper or p.e.t.p. tape separator Insulation: May be single or dual layer 01TQ Dual layer insulation EPR inner layer HOFR outer layer Temperature Rating: C maximum conductor operating temperature. Minimum handling temperature: -0 C Voltage: 0 V rating when used for welding purposes. For non-welding applications, cables may be used at voltages up to and including 0 Vrms phase - phase provided that the cables are adequately protected from damage to the insulation e.g. in panels etc. 1 1 Anixter Number Area Stranding Thickness of Covering Minimum O/D Maximum O/D Approximate Weight Colour mm #/mm mm mm mm kg/km Type 01TQ - Tinned Copper s WELD / Orange WELD-00-0 / Orange WELD / Orange WELD / Orange WELD / Orange WELD-00-0 / Orange WELD-0-0 0/ Orange WELD / Orange For further technical information see page :

36 1 Coil Lead 0 C/10 C Application Coil leads are designed for direct and permanent connection to coil winding of motors and other electrical apparatus. When used in coil lead applications, cable may also be required to withstand high temperatures or immersion in varnish or compound. May also be used for other applications such as flexible power leads Specifications In accordance with BS1 s: Flexible Class tinned copper conductors to BS EN 0 Insulation: Type - Rubber insulation Type OR1 to BS (HOFR Type) Type - Composite insulation Type FR1 (Voltage Categories A & C) or Type FR (Voltage Categories D, E & F) to BS. Inner Layer EPR or Butyl, Outer Layer HOFR) Type - Silicone rubber insulation Type EI. to BS Temperature Rating: 0 C maximum conductor operating temperature (Types & ). 10 C maximum conductor operating temperature (Type ) Voltage Rating: Voltage ratings for coil leads are divided into categories and define the maximum voltage between conductor and earth, to which the cable is liable to be subjected during a 1 minute test of the equipment to which it is connected The nominal voltage rating denotes the continuous operating voltage that the cable may be used at during service. Voltage Category Maximum Equipment Test Voltage (a.c. rms) Voltage Ratings of Cable Uo/U A. 00/00 V C.0 00/00 V D. 0/00 V E 1 00/00 V F 0/100 V 1 0 0

37 Anixter Number* Type, Category C Area mm Stranding #/mm Insulation Thickness (mm) Maximum O/D (mm) COIL-C / COIL-C / COIL-C / COIL-C / COIL-C-00. 0/ COIL-C / COIL-C / COIL-C-00 0/ COIL-C / COIL-C-00 1/ COIL-C-00 / COIL-C / COIL-C / Coil Lead 0 C/10 C COIL-C-00 / COIL-C-0 0/ COIL-C / COIL-C-10 1 /0... COIL-C-00 0 / COIL-C / COIL-C / For further technical information see page :. Approximate Cable Weight kg/km

38 1 Single-Core LSF Insulated 01B (1B up to and including 1.0mm ) 0 C 00/00 and 0/0 V Application For use in applications where greater flexibility is required to assist installation. Incorporates low smoke zero halogen insulation for use in areas where dense smoke and toxic fumes may cause a threat to life and equipment Specifications In accordance with BS and Cenelec Harmonised codes - H0Z-K (00/00 V cable) RoHS Compliant H0Z-K (0/0 V cable) RoHS Compliant s: Flexible Class copper conductors to BS EN 0 Insulation: Low smoke zero halogen thermosetting insulation Type EI. to BS EN 0-, having following characteristics: - Minimum oxygen index: 0% - Maximum HCL 00 C: 0.% Flame retardant to BS EN 0-- (up to and incl. 1.0mm ) and BS EN 0-1- (above 1.0mm ) Normal colours available see : Temperature Rating: 0 C maximum conductor operating temperature Voltage Rating: Up to and including 1.0mm - 00/00 V 1.mm and above - 0/0 V

39 Anixter Number Cenelec Code Area ## = colour, -01 = white, -0 = black, -0 = red, -0 = green, -0 = yellow, -0 = blue, -0 = brown, -0 = orange, -0 = grey, - = violet, -1 = pink, -0 = green/yellow. etc. Other colours available upon request. For further technical information see page :. Single-Core LSF Insulated 01B (1B up to and including 1.0mm ) Stranding Insulation Thickness 0 C 00/00 and 0/0 V Maximum O/D Approximate Weight mm #/mm mm mm kg/km ABS-000-## H0Z-K1 0. 1/ ABS-000-## H0Z-K1 0. / ABS-00-## H0Z-K1 1.0 / ABS-001-## H0Z-K1 1. 0/ ABS-00-## H0Z-K1. 0/ ABS-000-## H0Z-K1.0 / ABS-000-## H0Z-K1.0 / ABS-00-## H0Z-K1 0/ ABS-010-## H0Z-K1 1 1/ ABS-00-## H0Z-K1 1/ ABS-00-## H0Z-K1 / ABS-000-## H0Z-K1 0 / ABS-000-## H0Z-K1 0 0/ ABS-00-## H0Z-K1 / ABS-0-## H0Z-K1 0/ ABS-100-## H0Z-K1 10 / ABS-10-## H0Z-K1 1 / ABS-00-## H0Z-K1 0 /

40 1 LSZH Insulated and Sheathed Flexible Cords 0 C 00/00 V 1*B H0Z1Z1-F Application For external supply connection of portable appliances for medium duties in domestic or office environments. * denotes number of cores. 1 1 Specifications Generally in accordance with BS00 and meeting Harmonised code H0Z1Z1-F s: Flexible Class conductors to BS EN 0 Insulation: LSZH insulation Type TI. to HD 1.1 S1 Core Identification: core - blue, brown core - green/yellow, blue, brown core - green/yellow, brown, black, grey core - green/yellow, brown, black, grey, blue Sheath: LSZH sheath Type TM. to HD 1.1 S1 (white) Flame retardant to BS EN 0-1- Temperature Rating: 0 C maximum conductor operating temperature Voltage Rating: 00/00 V

41 Anixter Number Twin Core Type 1B Area LSZH Insulated and Sheathed Flexible Cords 0 C 00/00 V 1*B Stranding Insulation Thickness Minimum O/D Maximum O/D Approximate Cable Weight mm #/mm mm mm mm 1B-000-## 0. / B-00-## 1.0 / B-001-## 1. 0/ B-001-## 1. 0/ B-00-##. 0/ B-000-##.0 / Three Core Type 1B 1B-000-## 0. / B-00-## 1.0 / B-001-## 1. 0/ B-001-## 1. 0/ B-00-##. 0/ B-000-##.0 / Four Core Type 1B 1B-000-## 0. / B-00-## 1.0 / B-001-## 1. 0/ B-00-##. 0/ B-000-##.0 / Five Core Type 1B 1B-000-## 0. / B-00-## 1.0 / B-001-## 1. 0/ B-00-##. 0/ B-000-##.0 / ## = sheath colour, -01 = white, -0 = black. Other colours available upon request. For further technical information see page :

42 Flexible Cables & Cords Automotive Wire Current Ratings for Automotive Cables Current Ratings for Extra-Flexible Battery/Starter Cables Size Current Rating for Specified Duty Cycle (A) mm 0% 0% 0% % The above ratings are based on the following standard conditions: 0 C ambient air temperature 0 C maximum conductor temperature Current rating for repeat cycle operation based on a 1 minute repeat period: Repeat cycle operation used above is defined as a periodically switched constant load with an on-load period followed by an off-load period, which is repeated. The on-load time period is expressed as a percentage of the repeat period, and is called the percentage duty cycle. For on-load percentage greater than 0%, the 0% rating should be used

43 Flexible Cables & Cords Automotive Wire Current Ratings for Automotive Cables Ratings for other types of automotive wires should be based on the following table: Size Ambient Air Temperature Approximate Current Rating (0 C Temp) mm C A A Approximate Current Rating ( C Temp) N.B. Ratings are for guidance only, and assume single cable isolated in free air. If wires are to be grouped and touching, the following rating factors should be applied: No. cables in group Rating factor

44 1 1 1 Technical Specifications for Flexible Cords Applicable to: 1X, 1*Y, 1*Y, 0*Y, 1*B, 1*P, 1*TQ, *P H0V-K, H0VV-F, H0VV-F, H0VV-F, H0Z1Z1-F, H0RN-F, H0BN-F, H0RN-F CORRECTION FACTOR FOR AMBIENT TEMPERATURE 0 C rubber and PVC cords: Ambient air temp C 0 0 Rating factor C rubber cords having a HOFR sheath or a heat-resisting PVC sheath and for 0 C heat-resisting PVC cords: Ambient air temp C Rating factor C rubber cords: Ambient air temp C Rating factor For cables where four or more cores or loaded, the following factors should be applied: No. of cores loaded Rating factor No. of cores loaded Rating factor These factors need not be applied if the number of cores loaded does not exceed the square root of the total number of cores in the cable

45 Technical Specifications for Flexible Cords BS00, H0V-K, H0VV-F, H0VV-F, H0VV-F, H0Z1Z1-F, H0RN-F, H0BN-F, H0RN-F CURRENT CARRYING CAPACITY (Amperes): Cross Sectional Area 1 VOLTAGE DROP (per Ampere per metre): operating temperature: 0 C* Current Carrying Capacity Single Phase a.c. mm A A Cross Sectional Area 1 d.c. or Single Phase a.c. mm mv mv Three Phase a.c. Three Phase a.c. *NOTE: The tabulated values above are for 0 C rubber insulated and PVC-insulated flexible cords and for other types of flexible cords they are to be multiplied by the following factors: For 0 C rubber or PVC insulated C rubber insulated

46 Technical Specifications for H0V-K CURRENT CARRYING CAPACITY (Amperes): Cross Sectional Area Reference Method A (enclosed in conduit in thermally insulating wall etc) Cables, Single Phase a.c. or d.c. or Cables, Three Phase a.c. BS00-01X Types, PVC insulated only. Ambient temperature: 0 C operating temperature: 0 C. Reference Method B (enclosed in conduit on a wall or in trunking etc) Cables, Single Phase a.c. or d.c. 1 mm A A A A or Cables, Three Phase a.c

47 For ambient air temperatures other than 0 C, the following factors should be applied. Technical Specifications for H0V-K Ambient air temp C Rating factor VOLTAGE DROP (per Ampere per metre): Cross Sectional Area Cables d.c. Reference Methods A & B (enclosed in conduit etc in or on a wall) Cables Single Phase a.c. 1 mm mv mv mv Reference Methods A & B (enclosed in conduit etc in or on a wall) / Cables Three Phase a.c. r x z r x z

48 Technical Specifications for 01B CURRENT CAPACITY (Amperes): Cross Sectional Area Reference Method A (enclosed in conduit in thermally insulating wall etc) Cables, Single Phase a.c. or d.c. or Cables, Three Phase a.c. BS Ambient temperature: 0 C operating temperature: 0 C. For ambient air temperatures other than 0 C, the following factors should be applied. Ambient air temp C Rating factor Ambient air temp C 0 0 Rating factor Reference Method B (enclosed in conduit on a wall or in trunking etc) Cables, Single Phase a.c. or d.c. 1 mm A A A A or Cables, Three Phase a.c. 0 0

49 Technical Specifications for 01B 1 VOLTAGE DROP (per Ampere per metre): Cross Sectional Area Cables d.c. Reference Methods & (enclosed in conduit etc in or on a wall) Cables Single Phase a.c. Reference Methods & (enclosed in conduit etc in or on a wall) / Cables Three Phase a.c. 1 mm mv mv mv r x z r x z

50 Technical Specifications for Tri-Wire Area Stranding Current Rating Voltage Drop* mm #/mm A mv/a/m 0. 1/ / / / / / /0.. 0/ / / / / /0. 0. / / / / / Current ratings are based on a conductor operating temperature of C and an ambient air temperature of C and assumes single cable isolated in free air. The ratings do not apply if the cable is protected by a semi-enclosed fuse to BS0. For further guidance refer to the BS1 Requirements for Electrical Installations (IEE Wiring Regulations - latest edition). For ambient air temperature other than C the following rating factors should be applied: Ambient air temp C Rating factor Where cables are to be grouped, the following factors should be applied: No of cables in group Rating factor * The voltage drop figures quoted are for one cable only. For other circuit arrangements they should be adjusted as follows: Single phase 0Hz a.c. or -wire d.c. x Three phase a.c. x

51 Technical Specifications for Equipment Wires The upper temperature limits in the table opposite refer to the maximum continuous temperature of the conductor due to the combination of ambient temperature and temperature rise due to current flow. The lower values quoted are the minimum temperatures for equipment wire, which may be subject to slight flexing during their normal operating life. The current carrying capacities quoted are for wires carrying a continuous current in free air at an ambient temperature. NOTE: Current carrying capacities will depend on circumstances but for general guidance the quoted current values will give a temperature rise of about 1 C, in ambient temperatures up to 0 C for single, freely ventilated, insulated wires. Different values will apply when equipment wires are bunched

52 Technical Specifications for Equipment Wires Type of Equipment Wire Description Maximum a.c. (rms) d.c. 1 Hard PVC insulated 0 - Hard PVC insulated 1,000 - SB As Type, screened 1,000 - SBM As Type SB, with PVC sheath 1,000 - General purpose PVC insulated 1,00 - SB As Type, screened 1,00 - SBM As Type SB with PVC sheath 1,00 - Polyethylene insulated 1,00 - SB As Type, screened 1,00 - Silicone rubber insulated 0 - SB As Type, screened 0 - General purpose PVC insulated -,000 General purpose, PVC insulated -,000 General purpose, PVC insulated -,000 General purpose, PVC insulated - 1,000 Polyethylene insulated -,00 1 Polyethylene insulated - 1,000 1 Polyethylene insulated - 0,000 1 Silicone rubber insulated - 1,000 Type of Insulation Temperature Range Current Ratings PVC Hard grade -1º to +ºC 1/0. 0.A PVC General purpose -0º to +ºC /0. 1.A Polyethylene -0º to +ºC 1/0. 1.A Silicone rubber -0º to +10ºC 1/0..0A - - 1/0..0A - - /0..A - - 1/1.1.0A - - /0..0A - - /0..0A 0

53 Single-core, EPR insulated, HOFR sheathed. BS1-1TQ. Ambient temperature: 0 C operating temperature: 0 C. Technical Specifications for 1TQ 1 CURRENT CARRYING CAPACITY (Amperes): Cross Sectional Area Reference Method B (enclosed in conduit etc in or on a wall) Cables, Single Phase a.c. or d.c. or Cables, Three Phase a.c. Reference Method C (clipped direct) Cables, Single Phase a.c. or d.c. flat and touching 1 mm A A A A or Cables, Three Phase a.c. flat and touching or trefoil

54 Technical Specifications for 1TQ Ratings do not apply if the cable is protected by a semi-enclosed fuse to BS0. For further guidance refer to the BS1. Requirements for Electrical Installations (IEE Wiring Regulations - latest edition). For ambient air temperatures other than 0 C, the following factors should be applied. Ambient air temp C Rating factor Reference Method F (on a perforated cable tray) Horizontal or Vertical Cables, Single Phase a.c. or d.c. Flat and Touching or Cables, Three Phase a.c. Flat and Touching Reference Method G (Free Air) Single Phase a.c. or d.c. or Cables, Three Phase a.c. Flat Horizontal (H) or Vertical (V) Horizontal (H) Vertical (V) A A A A Cables Trefoil Three Phase a.c. Ratings shown in Column, also apply to cables in trefoil formation on a perforated cable tray, Reference Method F. 0 0

55 VOLTAGE DROP (per Amperes per metre): Cross Sectional Area * Spaced by one cable diameter. operating temperature: 0 C. Technical Specifications for 1TQ (continued) Cables - Single Phase a.c. Cables d.c. Reference Method B (enclosed in conduit etc in or on a wall) Reference Methods C & F (clipped direct or on trays, touching) 1 mm mv mv mv mv Reference Method G (spaced*) r x z r x z r x z

56 1 Technical Specifications for 1TQ Reference Method B (enclosed in conduit etc in or on a wall) Reference Methods C, F & G (in trefoil touching) or Cables - Three Phase a.c. Reference Methods C & F (flat touching) mv mv mv mv Reference Method G (flat spaced*) r x z r x z r x z r x z

57 CURRENT CARRYING CAPACITY (Amperes): Cross Sectional Area d.c. or Single Phase a.c. (1 Two Core cable, with or without protective conductor) Technical Specifications for *TQ Three Phase a.c. (1 Three Core, Four Core or Five Core cable) mm A A A Single Phase a.c. or d.c. Single-Core Cables Touching

58 1 Technical Specifications for *TQ The ratings do not apply if the cable is protected by a semi-enclosed fuse to BS0. For further guidance refer to the BS1 Requirements for Electrical Installations (IEE Wiring Regulations - latest edition). For ambient air temperature other than 0 C the following rating factors should be applied: Ambient air temp C Rating factor Ambient temperature: 0 C. operating temperature: C. NOTE: The current ratings tabulated are for cables in free air but may also be used for cables resting on a surface. See page : for Voltage Drops

59 VOLTAGE DROP (per Ampere per metre): Cross Sectional Area 1 Two Core or two Single-Core Cables d.c. * A larger voltage drop will result if cables are spaced. operating temperature: C. Technical Specifications for *TQ (continued) Two Core Cable Single Phase a.c. mm mv mv mv Three Core, Four Core or Five Core Cable Three Phase a.c. r x z r x z

60 1 Technical Specifications for *TQ Two Single-Core Cables Touching, Single Phase a.c.* mv r x z

61 Technical Specifications for H0RN-F The ratings do not apply if the cable is protected by a semi-enclosed fuse to BS0. For further guidance refer to the BS1 Requirements for Electrical Installations (IEE Wiring Regulations - latest edition). For ambient air temperature other than 0 C the following rating factors should be applied: Ambient air temp C Rating factor Ambient temperature: 0 C. operating temperature: 0 C. NOTE: The current ratings tabulated are for cables in free air but may also be used for cables resting on a surface. 1 VOLTAGE DROP (per Ampere per metre): Cross Sectional Area Two Core Cable d.c. Two Core Cable Single Phase a.c. 1 Three Core, Four Core or Five Core Cable Three Phase a.c. 1 mm mv mv mv r x z r x z

62 Technical Specifications for H0RN-F CURRENT CAPACITY (per Ampere per metre): Cross Sectional Area Single Phase a.c. or d.c. (1 two core cable, with or without protective conductor) Three Phase a.c. (1 three core, four core or five core cable) mm A A A Two Single-Core Cables Touching d.c. Single Phase a.c.* mv mv r x z * A larger voltage drop will result if cables are spaced. Single Phase a.c. or d.c. Single-Core Cables Touching 0

63 Technical Specifications for Welding Cables Welding cables are now used for many duties ranging from automatic welding machines where the current is carried continuously, to hand welding equipment which is used intermittently and where the cable has time to cool between the periods on load. In order to provide current ratings for intermittently loaded cables, the term duty cycle, sometimes called arcing time factor or load factor has been introduced. Duty cycle is defined as the ratio of the duration of operation under load, to the duration of a complete cycle. This ratio, lying between 0 and 1, may be expressed as a percentage. For example, if a cable carries its load current for six minutes followed by a period of four minutes off load and this cycle is repeated, every ten minutes, this gives a duty cycle of 0%. Welding equipment to BS is rated for repeat cycle operation based on a ten minute period. When authorised, a repeat cycle based on a five minute period may be used. The current rating tables give ratings corresponding to various duty cycles in common use. The following are typical duty cycles for various welding processes and applications. Automatic welding up to 0% Semi-Automatic welding 0-% Manual welding 0-0% Very intermittent or occasional welding up to 0%

64 Technical Specifications for Welding Cables CURRENT RATINGS OF CABLES WITH COPPER CONDUCTORS FOR REPEAT CYCLE BASED ON A MINUTE PERIOD Cross Current Rating at a Maximum Duty Cycle of Sectional Area of Cond 0% % 0% 0% % 0% % mm A A A A A A A Ambient air temperature C operating temperature: C Derating factors for higher ambient temperatures: 0 C C 0 C C NOTE: Cables operating at conductor temperatures of C, with the outer surface of the covering approximately C lower, could cause injury if carelessly handled after a period of use at the maximum rated current. CURRENT RATINGS OF CABLES WITH COPPER CONDUCTORS FOR REPEAT CYCLE BASED ON A MINUTE PERIOD Cross Current Rating at a Maximum Duty Cycle of Sectional Area of Cond 0% % 0% 0% % 0% % mm A A A A A A A Ambient air temperature C operating temperature: C Derating factors for higher ambient temperatures: 0 C C 0 C C NOTE: Cables operating at conductor temperatures of C, with the outer surface of the covering approximately C lower, could cause injury if carelessly handled after a period of use at the maximum rated current. 0

65 Technical Specifications for Welding Cables VOLTAGE DROP IN COPPER CONDUCTORS AT NORMAL AND ELEVATED TEMPERATURES Cross Sectional Area of Cond. d.c.* Voltage Drop/0A/m of Cable at 0ºC 0ºC ºC mm V V V The voltage drop values given above are for metres of cable carrying 0 amperes. For longer lengths of cable and heavier currents, the voltage drop value should be increased proportionally. *The corresponding values when using a.c. may be much higher depending on the inductance of the circuit

66 Technical Specifications for Coil Leads For ambient air temperatures other than 0/0 C, the following factors should be applied. Types and : Ambient temp C Rating factor Type : Ambient temp C Rating factor Where cables are to be grouped in free air, the following factors should be applied: Number of cables in group Rating factor Ambient air temperature 0 C, operating temperature 0 C. Area Stranding Maximum d.c. Resistance at 0ºC mm #/mm ohm/km amp 0. 1/ / / / /0.. /0.0. /0.0. 0/ / / / / / / / / / / / / Maximum Continuous Current Ratings (BS1) Types 0 0

67 GUIDE TO MINIMUM BENDING RADII ON FLEXIBLE CORDS AND CABLES 1 Cable Type Flexible Cable Thermoplastic (e.g. PVC) Cable Diameter (mm) > 1 >1 0 >0 M.B.R. (Minimum Bending Radius) Fixed installation D D D D Free movement* D D D D Flexible Cable Elastomeric (e.g. rubber) Fixed installation D D D D Free movement* D D D D Where D = cable diameter. The above values are based on recommendations given in BS0 Use of cables with a rated voltage not exceeding 0/0 V. *These values do not apply to cables used on festoon, reeling drum, cranes, robotics, etc., where repetitive flexing and/or twisting is anticipated. For further details refer to BS

68 0

Power and Wiring Cables

Power and Wiring Cables 1 Single-Core PVC 1X...................... 1: Single-Core PVC/PVC 1Y.................. 1: Flat Twin & Flat Three Core PVC /Y........ 1: Multicore XLPE/LSF/SWA/LSF BS Control Cable.............................

More information

Tri-Rated Flexible PVC Equipment Wire

Tri-Rated Flexible PVC Equipment Wire Application: High temperature, flame retardant wire designed for use in the switch control, relay and instrumentation panels of power switchgear and for purposes such as internal connectors in rectifier

More information

CURRENT RATINGS MORE THAN A CABLE

CURRENT RATINGS MORE THAN A CABLE CURRENT RTINGS Updated for the 17th Edition of the IEE Wiring Regulations MORE THN CBLE C O M P N Y EI CBLES, DURHM ROD, BIRTLEY, CO DURHM. DH3 2R Tel: +44 (0)191 410 3111 Fax: +44 (0)191 410 8312 E-mail:

More information

CONFLEX ELECTRIC CABLE

CONFLEX ELECTRIC CABLE CONFLEX ELECTRIC CABLE CONFLEX - 0.6/1kV Flexible VSD/EMC Cables Applications WW VSD/EMC cables are manufactured for use where electrical interference distorts signal transmission in electric motors. Standard

More information

FLEXIBLE INDUSTRIAL CABLES H07RN-F TENAFLEX SR

FLEXIBLE INDUSTRIAL CABLES H07RN-F TENAFLEX SR FLEXIBLE INDUSTRIAL CABLES H07RN-F TENAFLEX SR Standards : CENELEC HD 22.4 NF C 32-102-4 DIN VDE 0282-1 and VDE 0282-4 BS 6007 and BS 6500 IEC 60245-4 Rated voltage Rated voltage: 450/750 V (Use up to

More information

VIPERFLEX ELECTRIC CABLE

VIPERFLEX ELECTRIC CABLE VIPERFLEX Flexible Low Voltage Electric Cable - 0.6/1kV (Rubber insulated) H07 RN-F & H07 BN-F Single Core 2-Core 2-Core and Earth 3-Core and Earth 4-Core and Earth Multi-Core and Earth H07 RCN-F & H07

More information

ISO 9001 ISO 14001 CABLES AND WIRES CATALOGUE 2008

ISO 9001 ISO 14001 CABLES AND WIRES CATALOGUE 2008 ISO 9001 ISO 14001 CABLES AND WIRES CATALOGUE 2008 INTRODUCTION... 4 CHAPTER I SINGLE CORE NON-SHEATHED CABLES H05V-U, H05V-R, H05V-K... 6 H05V2-U, H05V2-R, H05V2-K... 7 H07V-U, H07V-R, H07V-K... 8 H07V2-U,

More information

ScottishPower Distribution Cables & Equipment. Metal Theft

ScottishPower Distribution Cables & Equipment. Metal Theft ScottishPower Distribution Cables & Equipment Metal Theft April 2012 As an aid to deterring to metal theft this booklet has been put together to help identify the types of utility power cables and associated

More information

Building Cables and Wires

Building Cables and Wires Building Cables and Wires 4 Introduction alfanar is equipped with state-of-the-art manufacturing facilities such as latest machineries, instrumentation, quality control and testing laboratory, etc., for

More information

with coloured cores and overall copper screen UL/CSA... 17

with coloured cores and overall copper screen UL/CSA... 17 CONTENT Cable Track Cables y SD 200 extremely flexible TPE/PUR data cable with coloured cores for continuous movement..... 6 y S 200 extremely flexible TPE/PUR control cable with numbered cores for continuous

More information

LEAD FREE FIREX. Interlock Armored Cables TECK90 and MC Industrial Cables. w w w. n e x a n s e n e r g y. c o m

LEAD FREE FIREX. Interlock Armored Cables TECK90 and MC Industrial Cables. w w w. n e x a n s e n e r g y. c o m FIREX Interlock Armored Cables TECK90 and MC Industrial Cables LEAD FREE O V E R 1 8 0 Y E A R S O F E X P E R I E N C E 866-663-9267 w w w. n e x a n s e n e r g y. c o m Interlock Armored Cables Introduction....2

More information

Gulf Cable & Electrical Ind. Co.

Gulf Cable & Electrical Ind. Co. CONTENTS INTRODUCTION PRODUCT RANGE I PRODUCT DATA TABLES XLPE INSULATED 600/1000V CABLES Two Core Cables CU/XLPE/PVC/LC/PVC/SWA/PVC 1 Three Core Cables CU/XLPE/PVC/LC/PVC/SWA/PVC 2 Four Core Cables CU/XLPE/PVC/LC/PVC/SWA/PVC

More information

FIRE RESISTANT CABLES FP200 GOLD

FIRE RESISTANT CABLES FP200 GOLD FIRE RESISTANT CABLES FP200 GOLD FIRE RESISTANT CABLES FP200 GOLD BS7629-1:2008 Certificate No 077f Certificate No 077k FP200 GOLD The original highly durable and dressable, easy to terminate and install

More information

Flexible cables for submersible products

Flexible cables for submersible products Flexible cables for submersible products Standards SUBCAB cables complies with the following general standards: IEC 6045 (general) IEC 608 class 5 (conductor) IEC 608-- CLAUSE 9 (oil resistant) IEC 608--

More information

FIRE RESISTANT CABLE CONSTRUCTION OF CABLES

FIRE RESISTANT CABLE CONSTRUCTION OF CABLES FIRE RESISTANT CABLE In all fire disasters, fire smoke, heat and toxic fumes are the main obstacles to safe evacuation of a building or area. A major contribution towards overcoming these hazards is the

More information

Flygt flexible cables

Flygt flexible cables Flygt flexible cables Contents Standards General SUBCAB 4 Screened SUBCAB 6 Rubber cable type: NSSHÖU-J 7 Screened rubber cable type: NSSHÖU../E + ST 8 FGB screened rubber cable 9 PUR control cable 0 HCR

More information

Airdac CNE and SNE, 600/1000V, Polyethylene Sheath, SANS 1507, NRS 063 & NRS 017

Airdac CNE and SNE, 600/1000V, Polyethylene Sheath, SANS 1507, NRS 063 & NRS 017 Airdac CNE and SNE, 600/1000V, Polyethylene Sheath, SANS 1507, NRS 063 & NRS 017 Conductor: Hard Drawn Copper Conductor Class 2 Insulation: LV-XLPE Phase Color Code(SNE): Red, Black & Bare Copper Phase

More information

e-mobility Special cables for electric vehicles Coroplast Fritz Müller GmbH & Co. KG Tapes Cables Cable Assemblies

e-mobility Special cables for electric vehicles Coroplast Fritz Müller GmbH & Co. KG Tapes Cables Cable Assemblies www.echtzeit.com e-mobility Coroplast Fritz Müller GmbH & Co. KG Tapes Cables Cable Assemblies Special cables for electric vehicles Wittener Straße 271 D-42279 Wuppertal Phone +49(0)202.2681.228 Fax +49(0)202.2681.360

More information

Fire Resistant Cables

Fire Resistant Cables 109/4 Fire Resistant Cables SR 114H Standard - SR 114E Enhanced BS 5839-1 BS 7629-1 BS 6387 BS 8434-1/2 BS 6425 BS 7622 EN 50200 World-wide recognized high quality cables Firecel SR114 are used in: Data

More information

Contact Hueson Corporation for additional information or details. http://www.huesonwire.com 38 Sutton Street Northbridge, MA 01534 508-234-6372

Contact Hueson Corporation for additional information or details. http://www.huesonwire.com 38 Sutton Street Northbridge, MA 01534 508-234-6372 Hueson Corporation of Northbridge MA, a specialty wire and cable manufacturer has recently introduced a solution to a long term industry challenge in the Trailer Cable Industry. Their solution involves

More information

www.ptranscable.com We specialize in low voltage cables including: Stranded Single Cable H07V-R Flexible Single Cable H05V-K

www.ptranscable.com We specialize in low voltage cables including: Stranded Single Cable H07V-R Flexible Single Cable H05V-K P-trans, meaning power transistor, is a well known cable manufacturer based in Aan - Jordan. The production plant produces all sorts of high quality low tension cables and is a leader in the industry supplying

More information

Flexible Control Cables

Flexible Control Cables Works photo: KUKA Flexible Control Cables A Flexible Control Cables Since generations people try to build machines and plants which shall take on different functions. To raise, sink, slide, drill, transport

More information

Global cable expertise for rolling stock

Global cable expertise for rolling stock Global cable expertise for rolling stock Global cable expertise for rolling stock Single and multicore Low voltage control cables Jumper cables HV roof cables (25 kv) rubber cables for power needs of locomotives

More information

Of wires & cables having nominal voltage up to 1000 V and heat resistant wire & cables, ambient temperature 30 C. Cable or lead category

Of wires & cables having nominal voltage up to 1000 V and heat resistant wire & cables, ambient temperature 30 C. Cable or lead category Table 12-1: Power rating : Power Rating Basic Table ÖLFLEX Of wires & cables having nominal voltage up to 1000 V and heat resistant wire & cables, ambient temperature 30 C Method of installation A Single

More information

Automotive Wire and Cable Products

Automotive Wire and Cable Products Automotive Wire and Cable Products Primary Wires: ISO: Classes B - H JASO: AEX, AESSX, AVX, AVSSX : TXL, GXL, STX Engine Harness Wire: AutoRad Transmission Wire: Silicon & Non-Silicon Blocked Sensor Cables:

More information

AFUMEX LSX LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 BASEC APPROVED PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:

AFUMEX LSX LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 BASEC APPROVED PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS: PRODUCT DATASHEET & APPLICATIONS GUIDE BASEC APPROVED AFUMEX LSX LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 KEY BENEFITS: BASEC approved for the full size range of BS8436 (1.0mm 2 to 2.5mm 2

More information

CLEVELAND CABLE LOCATIONS

CLEVELAND CABLE LOCATIONS A WORLD POWER IN CABLE SUPPLY THE CABLE AND ACCESSORY CATALOGUE 2011 2 CLEVELAND CABLE LOCATIONS CLEVELAND CABLE LOCATIONS 3 As is illustrated within our catalogue, we stock a comprehensive range of cables

More information

The Quality Connection. BETAflam Fire Resistant Safety Cables

The Quality Connection. BETAflam Fire Resistant Safety Cables The Quality Connection BETAflam Fire Resistant Safety Cables 2 Contact Consulting and sales Switzerland Phone +41 (0)62 288 82 82 Fax +41 (0)62 288 83 83 [email protected] www.leoni-infrastructure-datacom.com

More information

Hook-Up and Lead Wire

Hook-Up and Lead Wire 3.1 Hook-Up and Lead Wire 3 Table of Contents Hook-Up & Lead Wire Page Introduction: UL Style & CSA Type Listings 3.2 PVC 3.3 3.8 300V, 80 C 3.3 300V, 105 C 3.4 600V, 105 C 3.5 (Type MW) MIL-W-76C-PVC:

More information

WHITE PAPER Fire & safety performance standards

WHITE PAPER Fire & safety performance standards WHITE PAPER Fire & safety performance standards Terminologies describing Fire Performance Terminologies describing Fire Performance often present a challenge to understand as how they apply to a cable

More information

Generator DoCKInG StatIonS

Generator DoCKInG StatIonS Generator DOCKING STATIONS TRYSTAR Portable Power Cable Cam to cam cable extensions 2000V, 100A-400A rated to NEC table 400.5 (B) All portable power cable sold is highly flexible and UL & C-UL or CSA Listed

More information

Festoon 715 P PUR cable for flexible application in festoon systems

Festoon 715 P PUR cable for flexible application in festoon systems CABLES FOR CRANE AND CONVEYOR APPLICATIONS Festoon 715 P PUR cable for flexible application in festoon systems S AB BRÖCKSKES D-VIERSEN Festoon 715 P 1 x 16.0 mm 2 C Marking for Festoon 715 P 07150162:

More information

Terminal Cleaning and Protection

Terminal Cleaning and Protection Terminal Cleaning and Protection East Penn offers the most complete line of terminal cleaning and protection products. Boots Heat Shrink Tubing Cleaner and Protection Sprays Terminal Protectors 33 PAGES

More information

PROFIBUS cable. for PROFIBUS-PA and -DP 10/63-6.46 EN

PROFIBUS cable. for PROFIBUS-PA and -DP 10/63-6.46 EN for PROFIBUS-PA and -DP 10/63-6.46 EN CPN 080/CPE 080-Ex PROFIBUS-PA basis cable AWG 18, 0.88 mm 2 Use For fixed installation indoor and outdoor, on racks and in conduits. Application Fieldbus cable for

More information

108-93018 05 APR 2016 Rev M

108-93018 05 APR 2016 Rev M Product Specification 108-93018 05 APR 2016 Rev M Copper LAN Cable 1. SCOPE 1.1. Content This specification describes the general requirements for CommScope copper LAN cable. 2. APPLICABLE DOCUMENTS The

More information

ENERGY. TECWATER S1BN8-F 0,6/1 kv. Cable for Water Application

ENERGY. TECWATER S1BN8-F 0,6/1 kv. Cable for Water Application ENERGY TECWATER S1BN8-F 0,6/1 kv Cable for Water Application Technical Data Electrical parameters Thermal parameters Trademark Type designation Specification Approval Application Rated voltage Maximum

More information

100% EMI Emission Containment

100% EMI Emission Containment 100% EMI Emission Containment Designed for Longer Service Life Highly Flexible for Easier Handling and Faster Installation Authorized Distributor Industrial VFD Cables Index n Variable Frequency Drive

More information

< SD 200 C TP Continuously flexible TPE/PUR paired data cable with coloured cores and overall copper screen... 10

< SD 200 C TP Continuously flexible TPE/PUR paired data cable with coloured cores and overall copper screen... 10 CONTENT General < The Company..................................................................................... 3 Customized cables for different applications < Data / POF Cables POF-LWL and hybrid

More information

Chemical resistance Accidental

Chemical resistance Accidental Industrial flexible cable, insulation and outer sheath in elastomer Description Application TITANEX flexible cable is intended for installations with moving equipment, electric appliances and for building

More information

Standard Buccaneer - Ethernet

Standard Buccaneer - Ethernet IP6 rated compliant PUR jacket on cable Shielded system shielded coupler Shroud on RJ45 Screw coupling Rewireable flex connector PCB mounted panel connector IDC termination panel connector Earth lead version

More information

the quality par excellence Meghna Industries Manufacturer of : All types of fiberglass Cables

the quality par excellence Meghna Industries Manufacturer of : All types of fiberglass Cables the quality par excellence Meghna Industries Manufacturer of : All types of fiberglass Cables ABOUT US Since our beginning in 1995, We - MEGHNA INDUSTRIES have been one of the fastest growing manufacturer

More information

600V Power Cable 600V SOOW SOW

600V Power Cable 600V SOOW SOW 600V Power Cable Type SOOW UL/CSA 90 C 600V Part AWG No of Insulation Jacket Nominal Wieght/Mft Number Stranding conductors Thickness Thickness O.D. Nom. 18 2 SOOW 18 AWG 2.30 71 18 3 SOOW 16/.010 3.030

More information

CABLES FOR PHOTOVOLTAIC SOLAR ENERGY INSTALLATIONS FOR CLEAN ENERGY

CABLES FOR PHOTOVOLTAIC SOLAR ENERGY INSTALLATIONS FOR CLEAN ENERGY CABLES FOR PHOTOVOLTAIC SOLAR ENERGY INSTALLATIONS FOR CLEAN ENERGY One Company Connecting The World POWERFUL PRESENCE PRODUCTS PERFORMANCE PEOPLE General Cable has been a wire and cable innovator for

More information

Instrumentation Cable...14-17. Power Cable...2-11. Assembly Solutions...32

Instrumentation Cable...14-17. Power Cable...2-11. Assembly Solutions...32 Severe Cold Durability Exceeds CSA Cold Bend / Cold Impact (-0 C/-35 C) Drilling Mud Resistant Flame Retardant Certified to IEC 9-3 (33-3A) and IEEE 580 Oil Resistant Assemblies...3-33 Ester Based Mud

More information

From a single wire harness to an entire Electrical Distribution System (EDS), PKC delivers power where and when you need it.

From a single wire harness to an entire Electrical Distribution System (EDS), PKC delivers power where and when you need it. CATALOG INDEX Introduction 2 Overview 3 PVC-Automotive 5 PVC-UL and CSA 6 XLPE-Automotive 9 XLPE-UL and CSA 10 Metric Wire 11 Automotive Battery Cable 12 Boat Cable 12 Introduction PKC Group PKC Group

More information

Gulf Cable & Electrical Ind. Co.

Gulf Cable & Electrical Ind. Co. CONTENTS INTRODUCTION PRODUCT RANGE I PRODUCT DATA TABLES Irrigation 1 Coaxial s for T.V/ Satellite Antenna etc 2 Data Transmission s - 4 pair 24 AWG 3 TELEPHONE CABLES Telephone cables CCP-LAP & CCP-LAP-SS

More information

450-750 VOLTS - Copper conductor PVC insulated SSA 1320, IEC 60227 & BS 6004 HO 7V - U With Solid Conductor - TYPE 60227 IEC 01. Insulation Thickness

450-750 VOLTS - Copper conductor PVC insulated SSA 1320, IEC 60227 & BS 6004 HO 7V - U With Solid Conductor - TYPE 60227 IEC 01. Insulation Thickness 450 50 VOLTS Copper conductor PVC insulated SSA 320, IEC 6022 & BS 6004 HO V U With Solid TYPE 6022 IEC 0 For internal wiring equipment rated voltage up to 000 V AC and up to 50 V to earth. Catalogue Number

More information

4 IX D N E P P A Installation methods Current-carrying capacity and voltage drop for cables Reference method IET Wiring Matters

4 IX D N E P P A Installation methods Current-carrying capacity and voltage drop for cables Reference method IET Wiring Matters 8 Appendix 4 of BS 7671 by Mark Coles Appendix 4, Current-carrying capacity and voltage drop for cables and flexible cords, has seen significant changes with the publishing of BS 7671:2008. This article

More information

RADOX railway cables acc. to EN 50264 and EN 50306. Edition 2009

RADOX railway cables acc. to EN 50264 and EN 50306. Edition 2009 RADO railway cables acc. to EN 50264 and EN 50306 Edition 2009 Bridging our know how Interdisciplinary knowledge The HUBER+SUHNER Group is a leading international manufacturer of electrical and optical

More information

UGVCL/SP/591/11KV HT AB CABLE

UGVCL/SP/591/11KV HT AB CABLE TECHNICAL SPECIFICATION FOR 11KV AERIAL BUNCHED CABLES FOR OVERHEAD LINES (CROSSED LINKED POLYTHENE DRY GAS CURED) 1. SCOPE This specification covers requirements of XLPE insulated, 11 KV Aerial Bunched

More information

PROFIBUS cable. PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications

PROFIBUS cable. PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications Data Sheet 10/63-6.47-EN Rev. D PROFIBUS cable PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications PROFIBUS PA cables Non-Ex (Hazardous) applications Ex (Hazardous) applications

More information

BRÖCKSKES D-VIERSEN PV1-F 4,0 mm BRÖCKSKES D-VIERSEN PV1-F 4,0 mm d d 2 2 C VDE-REG.-Nr. 8292 10/2009

BRÖCKSKES D-VIERSEN PV1-F 4,0 mm BRÖCKSKES D-VIERSEN PV1-F 4,0 mm d d 2 2 C VDE-REG.-Nr. 8292 10/2009 d BRÖCKSKES BRÖCKSKES D-VIERSEN D-VIERSEN PV1-F PV1-F 4,0 mm 4,0 2 mm VDE-REG.-Nr. 2 C 8292 10/2009 s - THE COMPANY DIN EN ISO 9001 More than 60 years of experience in temperature measurement and control

More information

6 ELECTRICAL PARAMETERS

6 ELECTRICAL PARAMETERS 6 ELECTRICAL PARAMETERS For power, low voltage and medium voltage cables, cross section nominal areas are calculated in taking into account several parameters as: permissible current carrying capacities

More information

CIR. Index. Gexol. Standard CIR UL Listed Type TC-ER. Crush and Impact Resistant Without External Armoring. Arctic CIR UL Listed Type TC-ER-HL*

CIR. Index. Gexol. Standard CIR UL Listed Type TC-ER. Crush and Impact Resistant Without External Armoring. Arctic CIR UL Listed Type TC-ER-HL* Gexol CIR Crush and Impact Resistant Without External Armoring Passes the same stringent crush and impact testing required by UL 2225 for Type MC-HL n Available in Standard and Arctic Grade Jackets n Highly

More information

Electrical Safety Products

Electrical Safety Products Electrical Safety Products Trelleborg Electrical Safety Products A safe working environment is important in all industries, but in the electrical generation and supply industry, it is paramount. Trelleborg

More information

British Wire & Cable Manufacturers

British Wire & Cable Manufacturers British Wire & Cable Manufacturers Introduction For over 70 years Permanoid has been producing high quality cables, and today the company s wealth of experience in cable design, manufacture and polymer

More information

Cable flexibility Flexible. Chemical resistance Accidental

Cable flexibility Flexible. Chemical resistance Accidental H07RN-F Industrial flexible cable, insulation and outer sheath in elastomer Description pplication H07RN-F flexible cable is intended for installations with moving equipment, electric appliances and for

More information

LOW VOLTAGE POWER CABLES

LOW VOLTAGE POWER CABLES LOW VOLTAGE POWER CABLES CONTENTS 1 4 GENERAL INTRODUCTION TECHNICAL BARE SOFT DRAWN STRANDED CONDUCTORS 38 39 44 48 52 53 56 59 60 63 68 72 75 76 79 82 83 INFORMATION COPPER PVC INSULATED PVC SHEATHED

More information

Fire Performance Standard

Fire Performance Standard Fire Performance Standard At present, in cable industry, Fire Retardant, Low Smoke Halogen Free (LSZH), Low Smoke Fume (LSF) and Fire Resistant cables are all described as Fire survival Cables. Flame Retardant

More information

Gexol. Gexol. The Global Cable Solutions Company. Designed for safe, reliable performance in the harshest oil and gas operating environments

Gexol. Gexol. The Global Cable Solutions Company. Designed for safe, reliable performance in the harshest oil and gas operating environments Gexol Gexol World Class World Class Designed for safe, reliable performance in the harshest oil and gas operating environments Power Control Instrument VFD The Global Cable Solutions Company Gexol World

More information

DATA SHEET SERVO LK SMS FX8PLUS SIGNAL

DATA SHEET SERVO LK SMS FX8PLUS SIGNAL Application LAPP servo cables according to Siemens * (see footnote) Standard FX8008 PLUS SIGNAL are a new generation of very highly flexible screened signal (encoder and resolver)- cables (P/Ns 00277101

More information

UNDERSTANDING. C&M Corporation 51 South Walnut Street, Wauregan, CT 06387 Phone: 860.774.4812 Fax: 860.774.7330 www.cmcorporation.

UNDERSTANDING. C&M Corporation 51 South Walnut Street, Wauregan, CT 06387 Phone: 860.774.4812 Fax: 860.774.7330 www.cmcorporation. UNDERSTANDING UNDERSTANDING NFPA 79 By Ned Lloyd and Mike Levesque NFPA-79 is the electrical standard that has been developed by the National Fire Protection Association (NFPA) and is intended to minimize

More information

DIRECTCONNECT SERVICE

DIRECTCONNECT SERVICE DIRECTCONNECT SERVICE PRE-ASSEMBLED: LEADS, GROUNDS AND STINGERS/WHIPS Save Time, Labor and Money Lead Stinger/Whip Stock Colors (Blue, Green, Red, Yellow) available Stocked genuine Lenco and Tweco Connectors

More information

VDE-approved PVC-Control Cables

VDE-approved PVC-Control Cables Works photo: HELUKAEL VDE-approved PVC-Control Cables VDE-approved PVC-Control Cables This certification/licency is issued according to the rules of the HAR Agreement, wherein the certification/ licency

More information

Specializing in the cable business for over 38 years, PT. SUPREME CABLE

Specializing in the cable business for over 38 years, PT. SUPREME CABLE Specializing in the cable business for over 38 years, PT. SUPREME CABLE MANUFACTURING & COMMERCE Tbk. (PT. SUCACO Tbk) has grown steadly to become a largest and leading cable manufacturer, with international

More information

EcoFlex Cable. Smaller. Lighter. Tougher. 100% Recyclable.

EcoFlex Cable. Smaller. Lighter. Tougher. 100% Recyclable. EcoFlex Cable Smaller. Lighter. Tougher. 100% Recyclable. Total Performance, Completely Recyclable EcoFlex cable is Alpha Wire s newest innovation in control cabling. A true engineering breakthrough, EcoFlex

More information

MEDIUM VOLTAGE POWER CABLES

MEDIUM VOLTAGE POWER CABLES MEDIUM VOLTAGE POWER CABLES CONTENTS 1 GENERAL INTRODUCTION 4 TECHNICAL INFORMATION 15 25 35 45 Single Core XLPE Insulated PVC Sheathed Cables UNARMOURED CABLES COPPER UNARMOURED CABLES ALUMINUM ALUMINUM

More information

Trade of Electrician. Three-phase Distribution Boards And Socket Circuits

Trade of Electrician. Three-phase Distribution Boards And Socket Circuits Trade of Electrician Standards Based Apprenticeship Three-phase Distribution Boards And Socket Circuits Phase 2 Module No. 2.3 Unit No. 2.3.2 COURSE NOTES Created by Charlie Walsh - Athlone TC Revision

More information

WIRE, TERMINAL AND CONNECTOR REPAIR CONDUCTORS

WIRE, TERMINAL AND CONNECTOR REPAIR CONDUCTORS CONDUCTORS Conductors are needed to complete the path for electrical current to flow from the power source to the working devices and back to the power source. Special wiring is needed for battery cables

More information

BETAtrans. Cables and Systems for Rolling Stock. Edition 2006

BETAtrans. Cables and Systems for Rolling Stock. Edition 2006 BETAtrans Cables and Systems for Rolling Stock. Edition 2006 Info Consulting and Sales By Phone To ask for Information or to place an order please use the following number: +49 (0)9172-6844-11 By Fax For

More information

Outside Telephone Cable

Outside Telephone Cable Outside Telephone Cable Filled Core. Moisture Barrier. Description Soft copper wires insulated with high density polyethylene, foam skin or solid. Filled core, conformed by groups of pairs or by unit of

More information

ENERGY. TECSUN DUO (PV) Twin Cables for Photovoltaics

ENERGY. TECSUN DUO (PV) Twin Cables for Photovoltaics ENERGY TECSUN DUO (PV) Twin Cables for Photovoltaics Auswahlkriterien Manufacturer Trademark Approvals Application Prysmian Kabel und Systeme GmbH Kabel- und Leitungswerk Neustadt bei Coburg / Germany

More information

International Electrotechnical Commission Standards

International Electrotechnical Commission Standards International Electrotechnical Commission Standards Standard IEC 60028 IEC 60038 IEC 60050-461 IEC 60055-1 IEC 60055-2 IEC 60092-101 IEC 60092-350 IEC 60092-351 IEC 60092-352 IEC 60092-353 IEC 60092-354

More information

IEEE POWER ENGINEERING SOCIETY CHICAGO CHAPTER THE OKONITE COMPANY WEDNESDAY JANUARY 11, 2006 JIM FITZGERALD ENGINEERING LINGO

IEEE POWER ENGINEERING SOCIETY CHICAGO CHAPTER THE OKONITE COMPANY WEDNESDAY JANUARY 11, 2006 JIM FITZGERALD ENGINEERING LINGO IEEE POWER ENGINEERING SOCIETY CHICAGO CHAPTER THE OKONITE COMPANY WEDNESDAY JANUARY 11, 2006 JIM FITZGERALD ENGINEERING LINGO WHEN YOU HEAR AN ENGINEER SAY A NUMBER OF DIFFERENT APPROACHES ARE BEING IMPLEMENTED

More information

MICROCABLES. A complete vision of your connectivity needs. Catalogue

MICROCABLES. A complete vision of your connectivity needs. Catalogue MICROCABLES A complete vision of your connectivity needs Catalogue ELECTRONIC Filotex Introduction Application Nexans s line of microcables is designed towards the increasing requirements of electronics

More information

Type XHHW-2 or RHH/RHW-2/USE-2 GenFree II LSZH XLPO Single Conductor

Type XHHW-2 or RHH/RHW-2/USE-2 GenFree II LSZH XLPO Single Conductor TABLE OF CONTENTS SECTION I. SUBJECT SCOPE 2 II. APPLICABLE DOCUMENTS 2 III. CONDUCTOR 3 IV. SEPARATOR 3 V. INSULATION 3 A. 3-4 B. Electrical Properties 4 C. Flame Resistance 5 D. Smoke and Halogen Testing

More information

CONTENT. Robot cables. page. < The company... 3. < W - worldwide... 4. < Certifications... 5. < Clientele / supplier numbers... 6

CONTENT. Robot cables. page. < The company... 3. < W - worldwide... 4. < Certifications... 5. < Clientele / supplier numbers... 6 CONTENT page < The company............................................................................... 3 < W - worldwide...............................................................................

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60502-1 Second edition 2004-04 Power cables with extruded insulation and their accessories for rated voltages from 1 kv (U m = 1,2 kv) up to 30 kv (U m = 36 kv) Part 1: Cables

More information

HINDUSTAN PETROLEUM CORPORATION LIMITED ENGINEERING & PROJECTS GRESHAM ASSURANCE HOUSE, 2 ND FLOOR, A-1595(3) 1-A, SIR P M ROAD, FORT MUMBAI-400 001

HINDUSTAN PETROLEUM CORPORATION LIMITED ENGINEERING & PROJECTS GRESHAM ASSURANCE HOUSE, 2 ND FLOOR, A-1595(3) 1-A, SIR P M ROAD, FORT MUMBAI-400 001 NEW POL DEPOT AT HINDUSTAN PETROLEUM CORPORATION LIMITED ENGINEERING & S GRESHAM ASSURANCE HOUSE, 2 ND FLOOR, A-1595(3) 1-A, SIR P M ROAD, FORT MUMBAI-400 001 TECHNICAL SPECIFICATION OF XLPE, FRLS LT CABLES

More information

Network Standard Advice No. 1420C 9/6/2011

Network Standard Advice No. 1420C 9/6/2011 Network Standard Advice No. 1420C 9/6/2011 TO: Customers, Service Providers and Ausgrid Staff. Advisory Note on Changes to the Use of 11kV Cable Types. Introduction This Network Standard Advice (NSA) provides

More information

HOW TO CORRECTLY CONNECT DEEP CYCLE BATTERIES AND CHOOSE THE RIGHT CABLE SIZING

HOW TO CORRECTLY CONNECT DEEP CYCLE BATTERIES AND CHOOSE THE RIGHT CABLE SIZING HOW TO CORRECTLY CONNECT DEEP CYCLE BATTERIES AND CHOOSE THE RIGHT CABLE SIZING There are several ways to wire multiple batteries to achieve the correct battery voltage or capacity for a particular DC

More information

MEDIUM VOLTAGE CABLES Up to and including 36 KV

MEDIUM VOLTAGE CABLES Up to and including 36 KV MEDIUM VOLTAGE CABLES Up to and including 6 KV NOTICE As this catalogue is not intendedto cover all of LIBAN CABLES SAL possibilities in special cables manufacturing, the hereafter listing of the types

More information

Fire retardant IEC 60332-1

Fire retardant IEC 60332-1 300 / 500 V Description Approval Certificates VDE Reg N 7691 Application In dry and moist rooms for light mechanical stresses. Outdoors only when protected. Not in water. As supply and interconnecting

More information

Corporate Profile ROYAL. MODERN ROYAL ELECTRIC Ideal Power Solution MRE ELECTRICAL, INSTRUMENTATION & COMMUNICATION SYSTEMS

Corporate Profile ROYAL. MODERN ROYAL ELECTRIC Ideal Power Solution MRE ELECTRICAL, INSTRUMENTATION & COMMUNICATION SYSTEMS Corporate Profile MODERN ROYAL ELECTRIC Ideal Power Solution ROYAL MRE ELECTRICAL, INSTRUMENTATION & COMMUNICATION SYSTEMS MAJOR STOCKIST >>> CATHODIC PROTECTION CABLES >>> LOW VOLTAGE CABLES >>> MEDIUM

More information

Current Ratings. TABLE BEC 107. (Continued) Current ratings for 6350/11000 volts grade PILC/SWA/PVC cable to BS6480/69

Current Ratings. TABLE BEC 107. (Continued) Current ratings for 6350/11000 volts grade PILC/SWA/PVC cable to BS6480/69 Ratings TBLE BEC 107. (Continued) ratings for 60/11000 volts grade PILC/SW/PVC cable to BS64/69 CBLES LID IN IR: The ratings given in the foregoing tables are based on an ambient of C. It is recommended

More information

KNOW YOUR OPTIONS: 230 KV POWER CABLES

KNOW YOUR OPTIONS: 230 KV POWER CABLES KNOW YOUR OPTIONS: 230 KV POWER CABLES 71 CONDUCTOR MATERIAL AND SIZE Conductor material is a matter of both customer preference and required current carrying capacity At 230 kv, copper is most common

More information

Arbiter Systems Test Leads: Engineered for Optimum Performance and Safety

Arbiter Systems Test Leads: Engineered for Optimum Performance and Safety Arbiter Systems Test Leads: Engineered for Optimum Performance and Safety Arbiter Systems, Inc. test equipment offers outstanding performance, flexibility, and value. Our test leads offer nothing less.

More information

6000 Series Buccaneer

6000 Series Buccaneer Robust, instant connections for harsh environments 6000 Series Buccaneer - circular connectors that combine the ease of use of a push/pull coupling mechanism with proven environmental sealing. Available

More information

SCHEDULE ' A' TECHNICAL SPECIFICATION FOR 11/22/33KV H.T.XLPE POWER CABLE FOR DISTRIBUTION NETWORK IN MAHARASHTRA (SPECIFICATION NO.

SCHEDULE ' A' TECHNICAL SPECIFICATION FOR 11/22/33KV H.T.XLPE POWER CABLE FOR DISTRIBUTION NETWORK IN MAHARASHTRA (SPECIFICATION NO. SCHEDULE ' A' TECHNICAL SPECIFICATION FOR 11/22/33KV H.T.XLPE POWER CABLE FOR DISTRIBUTION NETWORK IN MAHARASHTRA (SPECIFICATION NO.MM/I/HTXLPE/2006) MAHARASHTRA STATE ELECTRICITY DISTRIBUTION CO.LTD.

More information

MV CABLE TYPE C 33-226

MV CABLE TYPE C 33-226 MV CABLE TYPE C 33-226 Standards : CENELEC HD 620 C 33-226 Rated voltage Rated voltage : 12/20 (24) kv Design 1 Stranded aluminium, class 2 conductor 2 Extruded conducting screen on conductor 3 XLPE insulation

More information

Athena is the name given to our assortment of electronic tapes. products of the very highest quality. These tapes both conduct and

Athena is the name given to our assortment of electronic tapes. products of the very highest quality. These tapes both conduct and Electric Athena. Athena is the name given to our assortment of electronic tapes products of the very highest quality. These tapes both conduct and insulate against electricity, in addition to warmth and

More information

C A B L E P R O T E C T I O N

C A B L E P R O T E C T I O N Safe cable protection! Elematic Cabling Systems produces in own plants a wide range of products for the cable protection, such as wiring spirals, insulated tubing, heat shrinkable tubing, etc. These products

More information

CAVEL VS80205 MADE IN ITALY 1000 V

CAVEL VS80205 MADE IN ITALY 1000 V 0,05 9,00 x 7,20 (Pet) (LSZH) Attached CE01 CE02 Sheath Colour black black red Non-migrating Polyester tape longitudinally overlapped (Pet) 25 x 23 µm Outer sheath of Thermoplastic material - black - halogen-free,

More information

3.6/6 kv XLPE insulated cables 5. 6/10 kv XLPE insulated cables 15. 8.7/15 kv XLPE insulated cables 25. 12/20 kv XLPE insulated cables 35

3.6/6 kv XLPE insulated cables 5. 6/10 kv XLPE insulated cables 15. 8.7/15 kv XLPE insulated cables 25. 12/20 kv XLPE insulated cables 35 CONTENTS INTRODUCTION 1 Cable selection, cable specification, cable services CABLES Constructional data: 3.6/6 kv XLPE insulated cables 5 SECTION 1 6/10 kv XLPE insulated cables 15 SECTION 2 8.7/15 kv

More information

Cables, Cable Laying & Accessories Manual

Cables, Cable Laying & Accessories Manual Distribution Business Cables, Cable Laying & Accessories Manual Database ref: File Ref: Title Page & Revision Log For Cables & Access v4 - Nov 2003.doc Manual Name: Cables & Accessories Manual Version

More information

A quick product finder for commercial applications JUDD WIRE INC. A member of the Sumitomo Electric Industries group of companies

A quick product finder for commercial applications JUDD WIRE INC. A member of the Sumitomo Electric Industries group of companies A quick product finder for commercial applications JUDD WIRE INC. A member of the Sumitomo Electric Industries group of companies Select, Customize, Order & Receive Products with Ease This catalog contains

More information

Section 5 161 kv Power Cables

Section 5 161 kv Power Cables Know Your Options: 161 kv Power Cable 61 material and size material is a matter of both customer preference and required current carrying capacity Copper conductor common for larger loads When both copper

More information

Offshore Transformer Platform. Technical Standard. Energinet.dk. HV, MV, LV and Signal Cables and Cable Routing

Offshore Transformer Platform. Technical Standard. Energinet.dk. HV, MV, LV and Signal Cables and Cable Routing Offshore Transformer Platform Technical Standard Energinet.dk HV, MV, LV and Signal Cables and Cable Routing ETS - 03 Rev. 1 Acadre doc. 44858-09 Revision survey Chpt. Description Revision Date Resp. -

More information

Industrial Cable Solutions for Variable Frequency Drives

Industrial Cable Solutions for Variable Frequency Drives Industrial Cable Solutions for Variable Frequency Drives Tough challenges call for innovative solutions, and General Cable is your worldwide source for new products and a wide range of industry-leading

More information

The Handbook 2013 EDITION

The Handbook 2013 EDITION The Handbook 2013 EDITION Trust Als you safe Alsecure is the cable you can stake your reputation on when safety and security are critical to maintain circuit integrity for mains power, lighting, alarms,

More information