1 ENERGY TECSUN DUO (PV) Twin Cables for Photovoltaics
2 Auswahlkriterien Manufacturer Trademark Approvals Application Prysmian Kabel und Systeme GmbH Kabel- und Leitungswerk Neustadt bei Coburg / Germany TECSUN DUO (PV) PV1-F PRYSMIAN Solar cables TECSUN DUO (PV) are intented for use in photovoltaic power supply systems and similar applications as free movable, free hanging, fixed installation and buried in ground in constructional secured systems. The cables can be used indoor, outdoor, in explosion hazard areas, in industry and agriculture. They are suitable for applications in/at equipment with protective insulation (protecting class II). In other respects IEC and 61646, IEC :2002 and DIN VDE 0100 part 520 applies. Technical Data Producer 1 operating voltage in AC systems operating voltage in DC systems Test voltage 0.7/1.2 kv 0.9/1.8 kv AC 6 kv / DC 10 kv (15 min.) Ampacity According to Requirements for cables for PV systems, DKE/VDE AK Tests According to HD conductor resistance, test voltages AC and DC, electric strength, surface resistance, spark test on insulation, insulation resistance at 20 C and 90 C in water and at 120 C in air. EN Part 6 - DC-stability (10 days, 85 C, salt water, 1.5 kv DC) TECSUN DUO (PV) Twin Cables for Photovoltaics ambient temperature Minimum permissible temperature operating temperature of the conductor Short-circuit temperature +90 C (stationary and in motion) -40 C (stationary and in motion) +120 C; Interpretation according to IEC 60216: permanent temperature 120 C for h (= 2.3 years), at max. 90 C permanent temperature (= 30 years) +250 C (at the conductor max. 5 sec.) Resistance to cold Bending test at low temperature according to DIN EN Impact test similar to DIN EN Damp-Heat Test According to EN h at 90 C and 85% humidity
3 Auswahlkriterien Thermal Parameters Tensile load Minimum bending radii Abrasion 15 N/mm² in operation, 50 N/mm² during installation see selection and ordering data According to DIN EN 53516: against abrasive paper Sheath against sheath (internal testing) Sheath against metal (internal testing) Sheath against plastics (internal testing) Shrinkage test According to EN Pressure test at high temperature According to EN Dynamic penetration test According to Requirements for cables for PV systems, DKE/VDE Shore-hardness 85 according to DIN EN Gnawer resistance An optimum of safety can be achieved with protective hoses and by use of special cable types with metallic coating such as spinning or braid. Chemical Parameters Mineral oil resistance 24h, 100 C according to DIN VDE , DIN EN Acid and alkaline resistance According to EN days, 23 C (N-Oxalic acid, N-Sodium hydroxide) Ammonia resistance Weather resistance Behaviour in case of fire Ecological innocuousness 30 days in saturated ammonia atmosphere (internal testing) Ozone resistance according to DIN EN test type B, HD 22.2 test type B UV-resistance according to UL 1581 (Xeno-Test), ISO (Method A) and HD605/A Absorption of water (gravimetric) according to DIN VDE , DIN EN Flame propagation Single cable according to DIN VDE 0482 Part , DIN EN Multiple cable according to DIN VDE 0482 Part , DIN EN Low smoke emission according to DIN VDE 0482 Part 268-2, IEC (light transmittance > 70%) Corrosivity according to DIN EN Toxicity according to DIN EN 50305, ITC-index < 3 TECSUN DUO (PV) cables complies with the codes 2000/53/EG, 2002/96/EG, 2003/11/EG and exempt from metallic lead-, mercury-, hexavalent chromium- und bromine containing compounds. RoHS conform.
4 Aufbaukriterien name wert Conductor Electrolytic copper, tinned, Class 5 according to IEC (DIN VDE 0295) Insulation Core identification Power Conductor Sheath Sheath-colours Marking TECSUN DUO (PV) HEPR 120 C similar to IEC (compound type EI6 / EI8) positive pole red, Negative pole black EVA 120 C based on DIN VDE 0282 part 1, HD 22.1 (compound type EM4 / EM8) Insulation and sheath are connected solidly (Two-layer-insulation ) black (rhombus) PRYSMIAN TECSUN (PV) PV1-F (cross-section) 0.6/1 KV (VDE- REG./TÜV)
5 Bestellinformationen Nennquerschnitt und Farbe Cu-Zahl Bestellnummer Leiterdurchmesser Außendurchmesser Mindestwert Außendurchmesser Höchstwert Leitungsgewicht netto ca. min. Biegeradius max. zulässige Zugbelastung Strombelastung bei 30 C [mm] (kg/km) [N] (A) test 2x 4 black each 5.6 each x 6 black each 6.1 each x10 black each 7.2 each x4 + 2x Irrtümer, Änderungen und Abweichungen vorbehalten. PRYSMIAN Germany Version: Datum:
BRÖCKSKES D-VIERSEN PV1-F 4,0 mm BRÖCKSKES D-VIERSEN PV1-F 4,0 mm d d 2 2 C VDE-REG.-Nr. 8292 10/2009
d BRÖCKSKES BRÖCKSKES D-VIERSEN D-VIERSEN PV1-F PV1-F 4,0 mm 4,0 2 mm VDE-REG.-Nr. 2 C 8292 10/2009 s - THE COMPANY DIN EN ISO 9001 More than 60 years of experience in temperature measurement and control
More informationENERGY. TECWATER S1BN8-F 0,6/1 kv. Cable for Water Application
ENERGY TECWATER S1BN8-F 0,6/1 kv Cable for Water Application Technical Data Electrical parameters Thermal parameters Trademark Type designation Specification Approval Application Rated voltage Maximum
More informationFestoon 715 P PUR cable for flexible application in festoon systems
CABLES FOR CRANE AND CONVEYOR APPLICATIONS Festoon 715 P PUR cable for flexible application in festoon systems S AB BRÖCKSKES D-VIERSEN Festoon 715 P 1 x 16.0 mm 2 C Marking for Festoon 715 P 07150162:
More informationPROFIBUS cable. for PROFIBUS-PA and -DP 10/63-6.46 EN
for PROFIBUS-PA and -DP 10/63-6.46 EN CPN 080/CPE 080-Ex PROFIBUS-PA basis cable AWG 18, 0.88 mm 2 Use For fixed installation indoor and outdoor, on racks and in conduits. Application Fieldbus cable for
More informationFLEXIBLE INDUSTRIAL CABLES H07RN-F TENAFLEX SR
FLEXIBLE INDUSTRIAL CABLES H07RN-F TENAFLEX SR Standards : CENELEC HD 22.4 NF C 32-102-4 DIN VDE 0282-1 and VDE 0282-4 BS 6007 and BS 6500 IEC 60245-4 Rated voltage Rated voltage: 450/750 V (Use up to
More informationCABLES FOR PHOTOVOLTAIC SOLAR ENERGY INSTALLATIONS FOR CLEAN ENERGY
CABLES FOR PHOTOVOLTAIC SOLAR ENERGY INSTALLATIONS FOR CLEAN ENERGY One Company Connecting The World POWERFUL PRESENCE PRODUCTS PERFORMANCE PEOPLE General Cable has been a wire and cable innovator for
More informationVIPERFLEX ELECTRIC CABLE
VIPERFLEX Flexible Low Voltage Electric Cable - 0.6/1kV (Rubber insulated) H07 RN-F & H07 BN-F Single Core 2-Core 2-Core and Earth 3-Core and Earth 4-Core and Earth Multi-Core and Earth H07 RCN-F & H07
More informationGlobal cable expertise for rolling stock
Global cable expertise for rolling stock Global cable expertise for rolling stock Single and multicore Low voltage control cables Jumper cables HV roof cables (25 kv) rubber cables for power needs of locomotives
More informationPROFIBUS cable. PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications
Data Sheet 10/63-6.47-EN Rev. D PROFIBUS cable PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications PROFIBUS PA cables Non-Ex (Hazardous) applications Ex (Hazardous) applications
More informationwith coloured cores and overall copper screen UL/CSA... 17
CONTENT Cable Track Cables y SD 200 extremely flexible TPE/PUR data cable with coloured cores for continuous movement..... 6 y S 200 extremely flexible TPE/PUR control cable with numbered cores for continuous
More informationCONFLEX ELECTRIC CABLE
CONFLEX ELECTRIC CABLE CONFLEX - 0.6/1kV Flexible VSD/EMC Cables Applications WW VSD/EMC cables are manufactured for use where electrical interference distorts signal transmission in electric motors. Standard
More informationCOAX Cables Radio Frequency Cables
COAX Cables Radio Frequency Cables Contents Page Table of contents Pictographs General information Introduction Types and abbreviations Temparature range Construction Characteristics Special constructions
More informationFire Resistant Cables
109/4 Fire Resistant Cables SR 114H Standard - SR 114E Enhanced BS 5839-1 BS 7629-1 BS 6387 BS 8434-1/2 BS 6425 BS 7622 EN 50200 World-wide recognized high quality cables Firecel SR114 are used in: Data
More informationBETAtrans. Cables and Systems for Rolling Stock. Edition 2006
BETAtrans Cables and Systems for Rolling Stock. Edition 2006 Info Consulting and Sales By Phone To ask for Information or to place an order please use the following number: +49 (0)9172-6844-11 By Fax For
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 60502-1 Second edition 2004-04 Power cables with extruded insulation and their accessories for rated voltages from 1 kv (U m = 1,2 kv) up to 30 kv (U m = 36 kv) Part 1: Cables
More informationMV CABLE TYPE C 33-226
MV CABLE TYPE C 33-226 Standards : CENELEC HD 620 C 33-226 Rated voltage Rated voltage : 12/20 (24) kv Design 1 Stranded aluminium, class 2 conductor 2 Extruded conducting screen on conductor 3 XLPE insulation
More informationPower and Wiring Cables
1 Single-Core PVC 1X...................... 1: Single-Core PVC/PVC 1Y.................. 1: Flat Twin & Flat Three Core PVC /Y........ 1: Multicore XLPE/LSF/SWA/LSF BS Control Cable.............................
More informationThe Quality Connection. BETAflam Fire Resistant Safety Cables
The Quality Connection BETAflam Fire Resistant Safety Cables 2 Contact Consulting and sales Switzerland Phone +41 (0)62 288 82 82 Fax +41 (0)62 288 83 83 sales@leoni-studer.ch www.leoni-infrastructure-datacom.com
More informationVDE-approved PVC-Control Cables
Works photo: HELUKAEL VDE-approved PVC-Control Cables VDE-approved PVC-Control Cables This certification/licency is issued according to the rules of the HAR Agreement, wherein the certification/ licency
More informationRADOX railway cables acc. to EN 50264 and EN 50306. Edition 2009
RADO railway cables acc. to EN 50264 and EN 50306 Edition 2009 Bridging our know how Interdisciplinary knowledge The HUBER+SUHNER Group is a leading international manufacturer of electrical and optical
More informationInternational Electrotechnical Commission Standards
International Electrotechnical Commission Standards Standard IEC 60028 IEC 60038 IEC 60050-461 IEC 60055-1 IEC 60055-2 IEC 60092-101 IEC 60092-350 IEC 60092-351 IEC 60092-352 IEC 60092-353 IEC 60092-354
More informationAFUMEX LSX LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 BASEC APPROVED PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:
PRODUCT DATASHEET & APPLICATIONS GUIDE BASEC APPROVED AFUMEX LSX LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 KEY BENEFITS: BASEC approved for the full size range of BS8436 (1.0mm 2 to 2.5mm 2
More informationKAT0130-0002a-E. Product Overview Cables
KAT0130-0002a-E Product Overview Cables Known brands - provided by experts Advantage 1 Safe choice of cables understanding the needs of our customers applications, we offer the safety of the right cable
More informationRELIABLE AND EFFICIENT MINING MINING CABLES
RELIABLE AND EFFICIENT MINING MINING CABLES 2 TABLE OF CONTENTS MINING CABLES 2 TELE-FONIKA KABLE 3 PRODUCTION POTENTIAL 5 VDE STANDARDS AND (HD) HARMONIZED STANDARDS OPEN PIT MINES R- (N)TSCGE WÖU 3.6/6
More informationRAIL /// WIRE & CABLE WHERE THE BEST IDEAS IN RAIL BEGIN
RAIL /// WIRE & CABLE WHERE THE BEST IDEAS IN RAIL BEGIN RAIL /// WIRE & CABLE EVERY CONNECTION COUNTS The Rail industry is changing rapidly, to match global demands for greener, more intelligent transportation.
More informationFlygt flexible cables
Flygt flexible cables Contents Standards General SUBCAB 4 Screened SUBCAB 6 Rubber cable type: NSSHÖU-J 7 Screened rubber cable type: NSSHÖU../E + ST 8 FGB screened rubber cable 9 PUR control cable 0 HCR
More informationFlexible cables for submersible products
Flexible cables for submersible products Standards SUBCAB cables complies with the following general standards: IEC 6045 (general) IEC 608 class 5 (conductor) IEC 608-- CLAUSE 9 (oil resistant) IEC 608--
More informationFire retardant IEC 60332-1
300 / 500 V Description Approval Certificates VDE Reg N 7691 Application In dry and moist rooms for light mechanical stresses. Outdoors only when protected. Not in water. As supply and interconnecting
More informationFIRE RESISTANT CABLES FP200 GOLD
FIRE RESISTANT CABLES FP200 GOLD FIRE RESISTANT CABLES FP200 GOLD BS7629-1:2008 Certificate No 077f Certificate No 077k FP200 GOLD The original highly durable and dressable, easy to terminate and install
More informationConductix-Wampfler Cables for Reeling Systems
Conductix-Wampfler Cables for Reeling Systems Cables for systems in motion selected from experts Advantage 1 Secure choice of cables Comprehension of our customers applications and needs is the foundation
More informationSeries 8146/5-V37 and Series 8150/5-V37
www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection
More informationISO 9001 ISO 14001 CABLES AND WIRES CATALOGUE 2008
ISO 9001 ISO 14001 CABLES AND WIRES CATALOGUE 2008 INTRODUCTION... 4 CHAPTER I SINGLE CORE NON-SHEATHED CABLES H05V-U, H05V-R, H05V-K... 6 H05V2-U, H05V2-R, H05V2-K... 7 H07V-U, H07V-R, H07V-K... 8 H07V2-U,
More informationTraveling Cable for Crane. www.tmc-cable.com. www.tmc-cable.com
Head Office / Ipjang Factory 443, Yeongok-gil, Ipjang-myeon, Seobuk-gu, Cheonan-si, Chungcheongnam-do, Korea Tel. +82-41-589-6500 Fax. +82-41-589-6400 Bukmyeon Factory 5, Myungduk 1-gil, Buk-myeon, Dongnam-gu,
More informationFlexible Control Cables
Works photo: KUKA Flexible Control Cables A Flexible Control Cables Since generations people try to build machines and plants which shall take on different functions. To raise, sink, slide, drill, transport
More informationRenewable energy. Inverters - Socomec G-1. Load break switches (Isolators) - Socomec G-2. Fuses - df G-3. Fuse bases.
G Product page Inverters - Socomec G-1 Load break switches (Isolators) - Socomec G-2 Fuses - df G-3 Fuse bases Surge protection - df G-3 - Wohner G-5 - CPT G-4 - Dehn G-5 Connectors - Wieland G-6 Cable
More informationDATA SHEET SERVO LK SMS FX8PLUS SIGNAL
Application LAPP servo cables according to Siemens * (see footnote) Standard FX8008 PLUS SIGNAL are a new generation of very highly flexible screened signal (encoder and resolver)- cables (P/Ns 00277101
More information< SD 200 C TP Continuously flexible TPE/PUR paired data cable with coloured cores and overall copper screen... 10
CONTENT General < The Company..................................................................................... 3 Customized cables for different applications < Data / POF Cables POF-LWL and hybrid
More informationAmpacity simulation of a high voltage cable to connecting off shore wind farms
Ampacity simulation of a high voltage cable to connecting off shore wind farms Eva Pelster 1, Dr. David Wenger 1 1 Wenger Engineering GmbH, Einsteinstr. 55, 89077 Ulm, mail@wenger-engineering.com Abstract:
More informationFIBER-OPTIC CABLES LWL-KABEL
FIBER-OPTIC CABLES LWL-KABEL FIBER-OPTIC LOOSE TUBE OUTDOOR CABLE LWL-BÜNDELADER AUSSENKABEL TECHNISCHE DATEN - Technical Data A-DQ(ZN)B2Y 1200 N A-DQ(ZN)B2Y 2500 N ECO-KABEL - ECO cable STANDARDKABEL
More informationAllweather and Rubber Cables
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 21 Owings Mills, MD 211 USA web: http://mdmetric.com ph: ()353130 (00)3130 fx: ()3532 (00)729329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
More informationChemical resistance Accidental
Industrial flexible cable, insulation and outer sheath in elastomer Description Application TITANEX flexible cable is intended for installations with moving equipment, electric appliances and for building
More informationCAVEL VS80205 MADE IN ITALY 1000 V
0,05 9,00 x 7,20 (Pet) (LSZH) Attached CE01 CE02 Sheath Colour black black red Non-migrating Polyester tape longitudinally overlapped (Pet) 25 x 23 µm Outer sheath of Thermoplastic material - black - halogen-free,
More informationLEAD FREE FIREX. Interlock Armored Cables TECK90 and MC Industrial Cables. w w w. n e x a n s e n e r g y. c o m
FIREX Interlock Armored Cables TECK90 and MC Industrial Cables LEAD FREE O V E R 1 8 0 Y E A R S O F E X P E R I E N C E 866-663-9267 w w w. n e x a n s e n e r g y. c o m Interlock Armored Cables Introduction....2
More informationInstrumentation Cable...14-17. Power Cable...2-11. Assembly Solutions...32
Severe Cold Durability Exceeds CSA Cold Bend / Cold Impact (-0 C/-35 C) Drilling Mud Resistant Flame Retardant Certified to IEC 9-3 (33-3A) and IEEE 580 Oil Resistant Assemblies...3-33 Ester Based Mud
More informationPVC YALITIMLI SÝNYAL VE KONTROL KABLOLARI PVC INSULATED SIGNAL AND CONTROL CABLES (VDE 0812-VDE 0814-VDE 0245)
LÝYY KABLO YAPISI: CONSTRUCTION: 1- ÝLETKEN : IEC-228 ;DIN VDE 0295;HD 383 SINIF-5 ELEKTROLÝTÝK BÜKÜLÜ BAKIR 2- YALITKAN : DIN VDE 0207 BÖLÜM-4 YI2 PVC KOMPAUND 3- YALITIM RENK : DIN 47100 4- BÜKÜM : UYGUN
More informationCIR. Index. Gexol. Standard CIR UL Listed Type TC-ER. Crush and Impact Resistant Without External Armoring. Arctic CIR UL Listed Type TC-ER-HL*
Gexol CIR Crush and Impact Resistant Without External Armoring Passes the same stringent crush and impact testing required by UL 2225 for Type MC-HL n Available in Standard and Arctic Grade Jackets n Highly
More informationThe Quality Connection. Cable Solutions for Mobile Networks Business Unit Telecom
The Quality Connection Cable Solutions for Mobile Networks Business Unit Telecom Connection Technology for Wireless Communication Systems A consistent focus on the market, in-depth sector and product knowledge,
More informationPCB transformers. Short circuit proof PCB transformer VB. General Data. Advantages. Applications. Circuit diagram. Standards & 1 Certifications W v
Short circuit PCB transformer General Data Rated input 230 Vac Rated output 6-2 x 24 Vac Rated power 0.35-3.2 VA Insulation class B Maximum ambient temperature 70 C Efficiency up to 58 % Degree of protection
More informationCABLE CLAMPS FOR SINGLE- AND MULTI-CORE CABLES
Î d - T CABLE CLAMPS FOR SINGLE- AND MULTI-CORE CABLES îd-t GmbH Hohe Straße 34-36 ph.: +49 6203 107 98 66 www.id-t.com 68526 Ladenburg fax: +49 6203 107 95 52 info@id-t.com Germany Version August 2014
More informationUGVCL/SP/591/11KV HT AB CABLE
TECHNICAL SPECIFICATION FOR 11KV AERIAL BUNCHED CABLES FOR OVERHEAD LINES (CROSSED LINKED POLYTHENE DRY GAS CURED) 1. SCOPE This specification covers requirements of XLPE insulated, 11 KV Aerial Bunched
More informationFIRE RESISTANT CABLE CONSTRUCTION OF CABLES
FIRE RESISTANT CABLE In all fire disasters, fire smoke, heat and toxic fumes are the main obstacles to safe evacuation of a building or area. A major contribution towards overcoming these hazards is the
More informationHigh-ohmic/high-voltage resistors
FEATURES These resistors meet the safety requirements of: UL1676 (range 510 kω to 11 MΩ) EN60065 BS60065 (U.K.) NFC 92-130 (France) VDE 0860 (Germany) High pulse loading capability Small size. APPLICATIONS
More informationTemperature Permissible ambient temperature. Weather Resistance to severe weather conditions. Impacts Cable mechanical resistance to impacts
Airfield Cables Issue 10/2003 Piktogramme Temperature Permissible ambient temperature Weather Resistance to severe weather conditions Impacts Cable mechanical resistance to impacts Chemical attacks Resistance
More informationCorporate Profile ROYAL. MODERN ROYAL ELECTRIC Ideal Power Solution MRE ELECTRICAL, INSTRUMENTATION & COMMUNICATION SYSTEMS
Corporate Profile MODERN ROYAL ELECTRIC Ideal Power Solution ROYAL MRE ELECTRICAL, INSTRUMENTATION & COMMUNICATION SYSTEMS MAJOR STOCKIST >>> CATHODIC PROTECTION CABLES >>> LOW VOLTAGE CABLES >>> MEDIUM
More informationROLLING STOCK CABLES
CABLES UNIPOLAIRES EXTRA-SOUPLE SANS GAINE UNSHEATHED SINGLE CORE CABLES WITH EXTRA-FLEXIBLE CONDUCTOR CARACTERISTIQUES DU CABLE CABLE CHARACTERISTICS - 40 C Bon Résistant à Bon / Good Tenue au feu Zero
More informationGexol. Gexol. The Global Cable Solutions Company. Designed for safe, reliable performance in the harshest oil and gas operating environments
Gexol Gexol World Class World Class Designed for safe, reliable performance in the harshest oil and gas operating environments Power Control Instrument VFD The Global Cable Solutions Company Gexol World
More informationTri-Rated Flexible PVC Equipment Wire
Application: High temperature, flame retardant wire designed for use in the switch control, relay and instrumentation panels of power switchgear and for purposes such as internal connectors in rectifier
More informationDigital input modules
8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a
More informationCLI CableLine Laser-printed Identification Cable markers and wire markers. Product information
CLI CableLine Laser-printed Identification Cable markers and wire markers Product information CLI CableLine Laser-printed Identification Introduction 4 s 5 Weidmüller tests and test procedures 6 Selection
More informationCABLE 101. The Basics of Wire & Cable. Copyright 2007, Belden Inc.
CABLE 101 The Basics of Wire & Cable Copyright 2007, Belden Inc. KEY TERMS Insulations Jacket Capacitance Attenuation Velocity of propagation Dielectric strength Dielectric constant Working voltage Elongation
More informationFlexible and safe solutions, for decades. Cables for alarmand safety systems
Flexible and safe solutions, for decades. Cables for alarmand safety systems 2 We offer the widest range of cables on the market for every kind of installation. It s all about reliability. It is always
More informationCABLE SPECIFICATION CAN CAB RJ45-SUBD9
CABLE SPECIFICATION All technical information contained in this document is the exclusive property of STI and may neither be used nor disclosed without its prior written consent. AAV 33801 1/8 Connector
More information3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance
SPECIFICATION FOR LOW VOLTAGE SWITCHBOARD SEN I N D E X Description 10 STANDARD TECHNICAL REQUIREMENTS 11 Standards 12 General Operating Conditions 13 General Description Of Switchboard 131 Structure 132
More information6000 Series Buccaneer
Robust, instant connections for harsh environments 6000 Series Buccaneer - circular connectors that combine the ease of use of a push/pull coupling mechanism with proven environmental sealing. Available
More informationRM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC
Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage
More information1 POLE 5 A (CADMIUM FREE CONTACTS TYPE) NY SERIES
POWER RELAY 1 POLE 5 A (CADMIUM FREE CONTACTS TYPE) NY SERIES RoHS compliant FEATURES Ultra slim type with 5 mm thickness Good for high density mounting Low power consumption and high sensitivity Nominal
More informationFOREWORD ONE OF THE WORLD S BIGGEST COMPANIES IN THE SECTOR.
OFFSHORE CABLES FOREWORD ONE OF THE WORLD S BIGGEST COMPANIES IN THE SECTOR. General Cable Corporation is one of the world s leading cable manufacturing companies. In its work it has contributed decisively
More informationElectrical Safety Products
Electrical Safety Products Trelleborg Electrical Safety Products A safe working environment is important in all industries, but in the electrical generation and supply industry, it is paramount. Trelleborg
More informationCables for Cranes, Lifts and Handling Systems
Cables for Cranes, Lifts and Handling Systems Cables for Cranes, Lifts and Handling Systems Edition 2003 Weights, dimensions and characteristics data are approximate. Deviations due to raw materials or
More informationCopper Cables CONNECTIVITY & CABLING SYSTEM
Copper Cables CONNECTIVITY & CABLING SYSTEM Category 5E M0502057-91 EN CPR 6707 U/UTP tested up to 200 MHz U/UTP CAT5E, unshielded 4-pair cable (100 Ohm), with PVC or LSZH (Low Smoke Zero Halogen) outer
More information100% EMI Emission Containment
100% EMI Emission Containment Designed for Longer Service Life Highly Flexible for Easier Handling and Faster Installation Authorized Distributor Industrial VFD Cables Index n Variable Frequency Drive
More informationNew Cable Tie Type Classifications
1 New Cable Tie Type Classifications UL 62275 United States CSA C22.2 No. 62275 Canada NMX-J-623-ANCE Mexico Technically Equivalent to IEC 62275 All cable ties are not created equal!!! With an increasing
More informationVdS 2100-09en. VdS Guidelines for water extinguishing systems. Non-return valves. Requirements and test methods. VdS 2100-09en : 2011-05 (01)
VdS Guidelines for water extinguishing systems VdS 2100-09en Requirements and test methods VdS 2100-09en : 2011-05 (01) Publishing house: VdS Schadenverhütung GmbH Amsterdamer Str. 172-174 50735 Köln,
More information7 Lighting Technology
7 Lighting Technology Series HS6145 For use in Zone 1 and Zone 2 Comply with requirements of Fire Department standard DIN 14 462 Battery state display Deep discharge protection Open circuit monitor Light
More informationHigh Ohmic/High Voltage Metal Glaze Leaded Resistors
High Ohmic/High Voltage Metal Glaze Leaded Resistors FEATURES Technology: Metal glaze A metal glazed film is deposited on a high grade ceramic body. After a helical groove has been cut in the resistive
More informationCoaxial cables? Video cables Loudspeaker cables
Photo: ELUKABEL Coaxial cables? Video cables Loudspeaker cables Coaxial cables? Video cables Loudspeaker cables Coaxial cables are used in all areas of the high frequency transmission technology, for example
More informationContact Hueson Corporation for additional information or details. http://www.huesonwire.com 38 Sutton Street Northbridge, MA 01534 508-234-6372
Hueson Corporation of Northbridge MA, a specialty wire and cable manufacturer has recently introduced a solution to a long term industry challenge in the Trailer Cable Industry. Their solution involves
More informationTechnical application guide IP codes in accordance with IEC 60529
www.osram.com Technical application guide IP codes in accordance with IEC 60529 What are IP codes? Depending on their potential exposure to foreign objects, electrical devices (e.g. luminaires, LED modules
More informationType XHHW-2 or RHH/RHW-2/USE-2 GenFree II LSZH XLPO Single Conductor
TABLE OF CONTENTS SECTION I. SUBJECT SCOPE 2 II. APPLICABLE DOCUMENTS 2 III. CONDUCTOR 3 IV. SEPARATOR 3 V. INSULATION 3 A. 3-4 B. Electrical Properties 4 C. Flame Resistance 5 D. Smoke and Halogen Testing
More informationHigh Voltage Systems. Today. The history of cables
High Voltage Cables High Voltage Systems Today Prysmian Cables and Systems B.V. is part of the Prysmian Group, a leading player in the industry of high-technology cables and systems for energy and telecommunications,
More informationPressure monitoring equipment for oil-sf 6. bushings, type GOEK
Pressure monitoring equipment for oil-sf 6 bushings, type GOEK Installation and maintenance guide 5693 827-6 en, Rev. 3, 2002-01-30 This document must not be copied without our written permission, and
More informationB05: Cable protection and sheathing
SHEATHING MATERIALS MDPE, BLACK This is the standard sheathing material for cables for outdoor use. The material is UV stabilised with using 2.5 ± 0.5 % carbon black. It has excellent weathering resistance.
More informationSection 5 161 kv Power Cables
Know Your Options: 161 kv Power Cable 61 material and size material is a matter of both customer preference and required current carrying capacity Copper conductor common for larger loads When both copper
More informationComprehensive safety concepts for building applications
Comprehensive safety concepts for building applications Preventive fire protection Experience, know-how, competence, quality and safety pyrofil for safety Fire reaction Dätwyler is the first european manufacturer
More information5SV Residual Current Protective Devices
s Siemens AG 2013 SENTRON 5SV Residual Current Protective Devices New portfolio for reliable personnel, material and fire protection Safe protection against residual currents Residual current protective
More informationPTC-Resistor Temperature-Sensors MINIKA to DIN 44 081 and DIN 44 082
PTC-Resistor Temperature-Sensors MINIKA to DIN 44 081 and DIN 44 082 General PTC-resistor temperature sensors (also called PTC-resistors or thermistors) are temperatur dependent semiconductor resistors
More informationR.C.C.B. s two-pole LEXIC
87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s two-pole LEXIC 089 06/09/10/11/12/15/16/17/18/ 27/28/29/30/35, CONTENTS PAGES 1. Electrical and mechanical characteristics...
More informationCommunication, Signal & Data Cables
Communication, Signal & Data Cables Used for indoor installation and interconnection of transmission, telephone, telegraph and electronic equipment as well as media equipments www.alfanar.com Communication
More informationWHITE PAPER Fire & safety performance standards
WHITE PAPER Fire & safety performance standards Terminologies describing Fire Performance Terminologies describing Fire Performance often present a challenge to understand as how they apply to a cable
More informationRedundancy Module QUINT-DIODE/40
Redundancy Module QUT DIODE provides: 00% decoupling of power supplies connected in parallel Can be installed in potentially explosive areas Load currents up to 60 A supported Easy assembly by snapping
More informationCompactLogix Power Supplies Specifications
Technical Data CompactLogix Power Supplies Specifications 1768 CompactLogix Power Supplies Catalog Numbers 1768-PA3, 1768-PB3 1769 Compact I/O Power Supplies Catalog Numbers 1769-PA2, 1769-PB2, 1769-PA4,
More information6 ELECTRICAL PARAMETERS
6 ELECTRICAL PARAMETERS For power, low voltage and medium voltage cables, cross section nominal areas are calculated in taking into account several parameters as: permissible current carrying capacities
More informationETHERLINE Ethernet Cable, Connectors & Tools
Ethernet Cable, ors & Tools 2 Pair 242 4 Pair 249 Industrial Ethernet ors & Tools 256 Ethernet Cable, ors & Tools ETHERNET CABLE, CONNECTORS & TOOLS Quick Select Chart 240 2 Pair 2 Pair: CAT.5/5e; Stationary
More informationHARTING Ethernet Cabling 4-poles Overview
Overview RJ45 Connectors [on page 8] System cables [on page 10] Distribution modules and Outlets [on page 20] HARTING PushPull Connectors [on page 22] System cables [on page 24] Panel feed-throughs [on
More information1 POLE - 5A SLIM POWER RELAY
POWER RELAY POLE - A SLIM POWER RELAY FTR-MY Series RoHS compliant FEATURES Width mm, height mm,(% smaller than NY series) area mm, super slim, low power, compact and light weight.gr. Nominal power: mw
More informationPOWER ROCKER SWITCH UL, CSA, VDE, TÜV, ÖVE, KEMA, SEMKO, NEMKO, DEMKO, FIMKO, SEV UL, CSA, VDE, TÜV, SEMKO, NEMKO, DEMKO, FIMKO, SEV, KEMA, ÖVE
POWER ROCKER SWITCH SWITCHES AJ8 switch standard actuator AJ8 switch Wide actuator RoHS Directive compatibility information http://www.nais-e.com/ FEATURES 1. Power rocker switches for safety requirements.
More informationThe optimum material solution for Low Voltage energy cables
The optimum material solution for Low Voltage energy cables About Borealis and Borouge Borealis is a leading provider of innovative solutions in the fields of polyolefins, base chemicals and fertilizers.
More information1.5. UL flammability ratings. *Nylon 6.6 = Polyamide 6.6 is Halogen-free and Silicone-free.
1.5 UL flammability ratings WWW.CABLEJOINTS.CO.UK THORNE & DERRICK UK TEL 0044 191 490 1547 FAX 0044 191 477 5371 TEL 0044 117 977 4647 FAX 0044 117 977 5582 WWW.THORNEANDDERRICK.CO.UK Flammability ratings
More informationThermal-Magnetic Circuit Breaker 3120-...-M1-..
Thermal-Magnetic Circuit Breaker -...-M-.. Description Single or two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 34). The addition of a magnetic tripping
More informationStandard Buccaneer - Ethernet
IP6 rated compliant PUR jacket on cable Shielded system shielded coupler Shroud on RJ45 Screw coupling Rewireable flex connector PCB mounted panel connector IDC termination panel connector Earth lead version
More information