Important Information: Complete Terms and Conditions are printed on sales invoices

Size: px
Start display at page:

Download "Important Information: Complete Terms and Conditions are printed on sales invoices"

Transcription

1

2 Important Information: Complete Terms and Conditions are printed on sales invoices Notice: L&H Group is continually working to improve and add new products to the Cable Express product range. For this and other reasons L&H Group may make changes to the product details set out in this Product Catalogue without further notice and any supply will be subject to availability at the time of the receipt of your order. On request, L&H Group will provide amended product particulars or details of suggested alternative or replacement products. This book was printed in September 2012 and subject to copyright, no part may be reproduced by any process without the written permission of L&H Group.

3 Welcome to Cable Express Enormous Range Comprehensive Information Immediate Availability C M Y We all understand that cable is often at the centre of everything you install. So it makes sense that the supply and availability of such a vital component in your world is made as easy as possible for you to access. Our Cable Express catalogue is one of the many ways we re trying to do exactly that. CM MY CY CMY It contains all the vital pieces of information on a large number of cables that you use everyday.as well as the ones you use every so often. We believe it is important that you can determine the best product for the job and do so quickly, easily and to the ultimate satisfaction of your customer. K More importantly, we have backed up this cable range with one of the most extensive ex stock cables services available in Australia today. Depending on where you are located, we can get cut to length cable to you same day if you don t want to drop by one of our Branches. The Cable Express catalogue is your essential guide to making your cable sourcing the easiest and quickest thing you will do all day, just another example of Our Promise, Great Service. Please talk to your local branch about our full range of cables and how we can continue to be a value adding supplier to your business.

4

5 Welcome to the L&H Group The L&H Group is a group of companies that provides products and services that meet the needs of electrical contractors, and commercial and industrial organisations across Australia and Asia Pacific. The group is made up of Lawrence and Hanson, Auslec, Pacific Datacom, Specialised Lighting Solutions (SLS), Smarter Clothing and Solar Plus Solutions. In their own way, all of these companies help fill a need. Whether that be the supply of everyday electrical products for an electrician via L&H, data solutions with Pacific Datacom, energy-efficient lighting products through SLS or a cost-effective clothing range from Smarter Clothing. Our group of companies complement each other in a way that others simply cannot offering you both product and technical expertise to help you get the most from it all. Please read on to understand how your dealings with the L&H Group can improve your overall company performance.

6 For over 125 years Australian electricians have come to Lawrence & Hanson for all of their electrical product needs. With over 165 branches around the country, L&H has a wide range of products and services that ensure electricians can get their job done quickly and efficiently. These products not only include all the well-known domestic and international electrical brands, but also include an extensive range of safety and industrial products designed to ensure electricians have all the right equipment to perform their duties. Ph:

7 Australia maintains a very strong industrial sector. With this comes the need for specialist suppliers who understand that a one solution fits all model simply doesn t work. For over 40 years, Auslec has been a leader within the industry, recognising that each product and service solution needs to be appropriately tailored to meet the needs of every customer. With branches around the country and strategic alliances with some of the world s most recognised suppliers, Auslec will deliver a result that you can be sure always meets your objectives. Ph: www. auslec.com.au

8 With the ever-increasing growth of new technologies, faster platforms of communication and an insatiable need for greater connectivity, Pacific Datacom has forged a leading reputation in the industry for supplying the appropriate products and expertise in assisting its customers. Products range from voice, video and data cabling networks through to wireless as well as fibre optic cabling solutions, racks, cabinets and critical cooling and power. You can be sure PDC has the solution for you. Pacific Datacom has a branch in each state and staff who are dedicated to ensuring its customers keep pace with change and can supply the latest innovative products in this ever-growing industry. We provide leading edge data and communications infrastructure solutions Ph:

9 Specialised Lighting Solutions (SLS) is a national leader in providing lighting services for retail, industrial, property management, hospitality and a host of other applications covering all spectrums of the market. SLS is able to provide the complete lighting solution for its customers. SLS services include: Lighting audit at site Accredited lighting design gnid Ongoing supply of replacement lamps under maintenance contract. Delivering energy efficient, environmentally friendly lamp and lighting solutions Ph:

10 A true supply innovator, Smarter Clothing prides itself on delivering tangible benefits in assisting you with your uniform management requirements. With an extensive range of garments numbering well over 40,000 and an online capability second to none, Smarter Clothing has saved thousands of dollars for its clients by providing services that its competitors can only dream of. Log on to today and complete a simple needs analysis online or simply browse the catalogue. We re sure you ll find the right solution for your business at the right price. Ph:

11 consumer demand for alternative sources of energy. Solar generated power is fast becoming a preferred source of household and industrial energy and with the experienced team at Solar Solutions, we re well placed to help connect our customers to the best product, range and support to ensure we service this industry effectively. gniworgsserd Renewable Energy Solutions Ph:

12 Index Cable and Wires Single Core Cable Building Wire, 1mm² Building Wire, 1.5mm² Building Wire, 2.5mm² Building Wire, 4mm² Building Wire, 6mm² Building Wire, 10mm² Building Wire, 16mm² Building Wire, 25mm² Building Wire, 35mm² Building Wire, 50mm² and Above Flexible,, Single Core Flexbile, Fire Rated, Single Core Flexible, Low Smoke Zero Halogen SDI, 1.0mm² SDI, 1.5mm² SDI, 2.5mm² SDI, 4mm² SDI, 6mm² SDI, 10mm² SDI, 16mm² Flexible: Versolex XLPE, SDI, 16mm² XLPE, SDI, 25mm² XLPE, SDI, 35mm² XLPE, SDI, 50mm² and Above Cable: Stranded Flat Cable Flat, 2C, 1.0mm² Flat, 2C+E, 1.0mm² Flat, 2C, 1.5mm² Flat, 2C+E, 1.5mm² Flat, 3C, 1.5mm² Flat, 3C+E, 1.5mm²

13 Index Flat, 2C, 2.5mm² Flat, 2C+E, 2.5mm² Flat, 3C+E, 2.5mm² Flat, 2C, 4mm² Flat, 2C+E, 4mm² Flat, 2C, 6mm² Flat, 2C+E, 6mm² Flat, 2C, 10mm² Flat, 2C+E, 10mm² Flat, 2C, 16mm² Flat, 2C+E, 16mm² Cable, Fire Alarm Flat 2C, 1.5mm² Low Voltage Multi Core Cable Cable Flexible: Titanex Circ, Orange, 2C+E, 1.5mm² to 4mm² (450/750V) Circ, Orange, Black 2C+E, 1.5mm² to 4mm² (0.6/1KV) Circ, Orange, 2C+E, 6mm² (450/750V) Circ, Orange, 2C+E, 6mm² to 35mm² (0.6/1KV) Circ, Orange, 3C+E, 1.5mm² to 2.5mm² (450/750V) Circ, Orange, 3C+E, 2.5mm² (0.6/1KV) Circ, Orange 3C+E, 4mm² to 6mm² (450/750V) Circ, Orange 3C+E, 4mm² to 70mm² (0.6/1KV) Circ, Orange 4C+E, 1.5mm² to 2.5mm² (450/750V) Circ, Orange 4C+E, 1.5mm² to 2.5mm² (0.6/1KV) Circ, Black 4C+E, 1.5mm² (0.6/1KV) Circ, Orange 4C+E, 4mm² to 6mm² (450/750V) Circ, Orange 4C+E, 4mm² to 16mm² (0.6/1KV) Circ, Orange 4C+E, 25mm² to 120mm² (0.6/1KV) Flex,, MultiCore O/DTY Flex,, MultiCore H/DTY SWA, 1.5mm² to 16mm² SWA, 25mm² to 240mm² XLPE,, Multicore Varolex, Circ 2.5mm² to 240mm² Cable, Fire Rated Multicore Cable, Fire Alarm Round 2C, 1.5mm² Cable: Mains

14 Index Cable:Underground Residential Distribution Cable: Mining High Voltage Power Cable Cable: High Voltage 70mm² & 95mm² Control Cable Circ, Control, 6 to 12 Core Circ, Control, 20 to 50 Core Flex, Control 6 to 17 Core SWA, Control, 6 to 30 Core Data Cable Cable, Data, Cat 5E & Cable, Data Cable, Traffic Feeder Cable: Detonator Speaker Cable Cable, Speaker, Figure Signal & Telecommunications Cable Cable: Garden Cable: Security Cable: Instrumentation Cable: Instrumentation-Fire Rated Cable: Telephone Coaxial Cable Cable: Coaxial Cable Glands Cable Gland Glands - General Purpose, for Armoured Cable Glands - General Purpose, for Unarmoured Cable Glands - Hazardous Area, for /SWA Cable Glands - Hazardous Area, for Unarmoured Cable Glands - Hazardous Area, for Unarmoured Cable Glands + Hose Adapter - Hazardous Area, for Unarmoured Cable Glands - Metal, for Emc Shielded Cables

15 Index Glands - Metal, for Screened Cables Glands - Barrier for Armoured Cables Glands - Metal, Shutter Type for Unarmoured cable Glands - S/S, Shutter Type Glands - Nylon: Alco, for Cable Glands - Nylon: Tradeforce, for Cable Sealing Disc for Cable Gland Washer - Fibre Cable Gland Shroud Glands - Shroud, Glands - Shroud, Rubber Cable Joint Branch Kit Resin Joints - Type Y Cable Resin Cast Resin - Type EG (Non-Removable) Cast Resin - Type KG (Removable) Putty - Insul/Epoxy resin Straight-through Heatshrink and Cast Joints Cast Resin Joints - Type M Cast Resin Joints - Type MZ Earthing Lug for Cable Gland Earth Tags - Metal Locknuts and Lockrings Locknuts - Metal Locknuts - Metal, For EMC Glands Pressure Spring Pressure Springs

16 Cable and Wires Single Core Cable Building Wire, 1mm² Nominal cross section conductor: Number of strand and size: Length: Outer diameter approx.: Cable application: Nominal voltage from to: Solid 1 mm² 1C 1/1.13mm 100 m 2.8 mm Building wire kv OLX1/113BWBK Sheath colour Black Red White BAAP02A1001AABK BAAP02A1001AARD BAAP02A1001AAWT OLX1/113BWBK OLX1/113BWR OLX1/113BWW Building Wire, 1.5mm² Nominal cross section conductor: Number of strand and size: Length: Outer diameter approx.: Nominal voltage from to: Stranded 1.5 mm² 1C 7/0.50mm 100 m 3.1 mm kv OLX7/050BWBK Sheath colour Black Blue Grey Red White Green-yellow Cable application Building wire Building wire Building wire Building wire Building wire Earth wire BAAP05A1001AABK BAAP05A1001AABE BAAP05A1001AAGY BAAP05A1001AARD BAAP05A1001AAWT AATP05A1001AAHN OLX7/050BWBK OLX7/050BWBL OLX7/050BWGY OLX7/050BWR OLX7/050BWW OLX7/050EW 14

17 Cable and Wires Single Core Cable Building Wire, 2.5mm² Nominal cross section conductor: Number of strand and size: Outer diameter approx.: Nominal voltage from to: Stranded 2.5 mm² 1C 7/0.67mm 3.6 mm kv OLX7/067BWBK Sheath colour Length Cable application Black 100 m Building wire Black 500 m Building wire Blue 100 m Building wire Red 100 m Building wire White 100 m Building wire Grey 100 m Building wire Red 500 m Building wire White 500 m Building wire Green-yellow 100 m Earth wire Green-yellow 500 m Earth wire BAAP07A1001AABK BAAP07A5001AABK BAAP07A1001AABE BAAP07A1001AARD BAAP07A1001AAWT BAAP07A1001AAGY BAAP07A5001AARD BAAP07A5001AAWT AATP07A1001AAHN AATP07A5001AAHN OLX7/067BWBK OLX7/067BWBKA5 OLX7/067BWBL OLX7/067BWR OLX7/067BWW OLX7/067BWGY OLX7/067BWRA5 OLX7/067BWWA5 OLX7/067EW OLX7/067EWA5 Building Wire, 4mm² Nominal cross section conductor: Number of strand and size: Outer diameter approx.: Nominal voltage from to: Stranded 4 mm² 1C 7/0.85mm 4.5 mm kv OLX7/085BWBK Sheath colour Length Cable application Black 100 m Building wire Blue 100 m Building wire Blue 500 m Building wire Green-yellow 100 m Earth wire Red 100 m Building wire White 100 m Building wire Green-yellow 500 m Earth wire BAAP09A1001AABK BAAP09A1001AABE BAAP09A5001AABE BAAP09A1001AAHN BAAP09A1001AARD BAAP09A1001AAWT BAAP09A5001AAHN OLX7/085BWBK OLX7/085BWBL OLX7/085BWBLA5 OLX7/085BWEW OLX7/085BWR OLX7/085BWW OLX7/085BWEWA5 15

18 Cable and Wires Single Core Cable Building Wire, 6mm² Nominal cross section conductor: Number of strand and size: Outer diameter approx.: Nominal voltage from to: Stranded 6 mm² 1C 7/1.04mm 5.1 mm kv OLX7/104BWBK Sheath colour Length Cable application Black 100 m Building wire Red 100 m Building wire White 100 m Building wire Black 500 m Building wire Blue 100 m Building wire Red 500 m Building wire Green-yellow 100 m Earth wire Green-yellow 500 m Earth wire BAAP11A1001AABK BAAP11A1001AARD BAAP11A1001AAWT BAAP11A5001AABK BAAP11A1001AABE BAAP11A5001AARD BAAP11A1001AAHN BAAP11A5001AAHN OLX7/104BWBK OLX7/104BWR OLX7/104BWW OLX7/104BWBKA5 OLX7/104BWBL OLX7/104BWRA5 OLX7/104BWEW OLX7/104BWEWA5 Building Wire, 10mm² Nominal cross section conductor: Number of strand and size: Outer diameter approx.: Nominal voltage from to: Stranded 10 mm² 1C 7/1.35mm 6 mm kv OLX7/135BWBK Sheath colour Length Cable application Black 100 m Building wire Black 500 m Building wire Red 100 m Building wire Blue 100 m Building wire White 100 m Building wire Red 500 m Building wire Green-yellow 100 m Earth wire Green-yellow 500 m Earth wire BAAP13A1001AABK BAAP13A5001AABK BAAP13A1001AARD BAAP13A1001AABE BAAP13A1001AAWT BAAP13A5001AARD BAAP13A1001AAHN BAAP13A5001AAHN OLX7/135BWBK OLX7/135BWBKA5 OLX7/135BWR OLX7/135BWBL OLX7/135BWW OLX7/135BWRA5 OLX7/135BWEW OLX7/135BWEWA5 16

19 Cable and Wires Single Core Cable Building Wire, 16mm² Nominal cross section conductor: Number of strand and size: Outer diameter approx.: Nominal voltage from to: Stranded 16 mm² 1C 7/1.70mm 6.9 mm kv OLX7/170BWBK Sheath colour Length Cable application Black 100 m Building wire Black 500 m Building wire Blue 100 m Building wire Blue 500 m Building wire Red 100 m Building wire Red 500 m Building wire White 100 m Building wire White 500 m Building wire Green-yellow 100 m Earth wire Green-yellow 500 m Earth wire BAAP15A1001AABK BAAP15A5001AABK BAAP15A1001AABE BAAP15A5001AABE BAAP15A1001AARD BAAP15A5001AARD BAAP15A1001AAWT BAAP15A5001AAWT BAAP15A1001AAHN BAAP15A5001AAHN OLX7/170BWBK OLX7/170BWBKA5 OLX7/170BWBL OLX7/170BWBLA5 OLX7/170BWR OLX7/170BWRA5 OLX7/170BWW OLX7/170BWWA5 OLX7/170BWEW OLX7/170BWEWA5 Building Wire, 25mm² Nominal cross section conductor: Number of strand and size: Outer diameter approx.: Nominal voltage from to: Compounded 25 mm² 1C 19/1.35mm 8.4 mm kv OLX19/135BWBKA5 Sheath colour Length Cable application Black 500 m Building wire Green-yellow Earth wire Red 500 m Building wire Red 100 m Building wire Green-yellow 100 m Earth wire Black Building wire Red Building wire Green-yellow 500 m Earth wire BAAC17A5001AABK BAAC17AA001AAHN BAAC17A5001AARD BAAC17A1001AARD BAAC17A1001AAHN BAAC17AA001AABK BAAC17AA001AARD BAAC17A5001AAHN OLX19/135BWBKA5 OLX19/135BWEW OLX19/135BWRA5 OLX19/135BERA1 OLX19/135EWA1 OLX19/135BWBK OLX19/135BWR OLX19/135BWEWA5 17

20 Cable and Wires Single Core Cable Building Wire, 35mm² Nominal cross section conductor: Number of strand and size: Outer diameter approx.: Nominal voltage from to: Compounded 35 mm² 1C 19/1.53mm 9.4 mm kv OLX19/153BWEW Sheath colour Length Cable application Green-yellow Earth wire Green-yellow 100 m Earth wire Red Building wire Red 500 m Building wire Black 500 m Building wire BAAC18AA001AAHN BAAC18A1001AAHN BAAC18AA001AARD BAAC18A5001AARD BAAC18A5001AABK OLX19/153BWEW OLX19/153BWEWA1 OLX19/153BWR OLX19/153BWRA5 OLX19/153BWBKA5 Building Wire, 50mm² and Above Nominal voltage from to: 1C kv OLX19/178BWEW Conductor category Nominal cross section conductor Number of strand and size Core insulation Sheath colour Outer diameter approx. Cable application Compounded 50 mm² 19/1.78mm Green-yellow 10.9 mm Earth wire Compounded 70 mm² 19/2.14mm Green-yellow 12.4 mm Earth wire Compounded 70 mm² 19/2.14mm Building wire Compounded 95 mm² 37/1.78mm Green-yellow 15.2 mm Earth wire Stranded 120 mm² 37/2.03mm Green-yellow 17.3 mm Earth wire Stranded 120 mm² 37/2.03mm Black 17.3 mm Building wire Compounded 240 mm² 61/2.25mm Green-yellow 24.1 mm Earth wire BAAC19AA001AAHN BAAC20AA001AAHN ACUC20AA001AAAA BAAC22AA001AAHN BAAP23AA001AAHN BAAP23AA001AABK BAAP26AA001AAHN OLX19/178BWEW OLX19/214BWEW OLX19/214BWBARE OLX37/178BWEW OLX37/203BWEW OLX37/203BWBK OLX37/288BWEW 18

21 Cable and Wires Single Core Cable Flexible,, Single Core Length: Nominal voltage from to: Flexible 1C 100 m kv OLX24/020-1BL Nominal cross section Number of strand and size Sheath colour Outer diameter approx. conductor 0.75 mm² 24/0.20mm Blue 2.7 mm 0.75 mm² 24/0.20mm Brown 2.7 mm 0.75 mm² 24/0.20mm Grey 2.7 mm 0.75 mm² 24/0.20mm Orange 2.7 mm 0.75 mm² 24/0.20mm White 2.7 mm 1 mm² 32/0.20mm Black 2.9 mm 1 mm² 32/0.20mm Brown 2.9 mm 1 mm² 32/0.20mm Orange 2.9 mm 1 mm² 32/0.20mm Red 2.9 mm 1.5 mm² 30/0.25mm Black 3.2 mm 1.5 mm² 30/0.25mm Green-yellow 3.2 mm 1.5 mm² 30/0.25mm Grey 3.2 mm 1.5 mm² 30/0.25mm Orange 3.2 mm 1.5 mm² 30/0.25mm Red 3.2 mm 1.5 mm² 30/0.25mm White 3.2 mm BAAR02A1001AABE BAAR02A1001AABN BAAR02A1001AAGY BAAR02A1001AAOG BAAR02A1001AAWT BAAR03A1001AABK BAAR03A1001AABN BAAR03A1001AAOG BAAR03A1001AARD BAAR04A1001AABK BAAR04A1001AAHN BAAR04A1001AAGY BAAR04A1001AAOG BAAR04A1001AARD BAAR04A1001AAWT OLX24/020-1BL OLX24/020-1BR OLX24/020-1GY OLX24/020-1O OLX24/020-1W OLX32/020-1BK OLX32/020-1BR OLX32/020-1O OLX32/020-1R OLX30/025-1BK OLX30/025-1EW OLX30/025-1GY OLX30/025-1O OLX30/025-1R OLX30/025-1W 19

22 Cable and Wires Single Core Cable Flexbile, Fire Rated, Single Core Series or range: Pyrolex ceramifiable Flexible 1C Sheath colour: Red Nominal voltage from to: kv Operating temperature, flexible: 110 C Halogen free: Yes OLX348/020-1CR Nominal cross section conductor Number of strand and size Outer diameter approx. 10 mm² 348/0.20mm 9.4 mm 16 mm² 528/0.20mm 10.4 mm 25 mm² 816/0.20mm 12 mm 35 mm² 1179/0.20mm 13.6 mm 50 mm² 696/0.30mm 15.6 mm 70 mm² 972/0.30mm 17.3 mm 95 mm² 1296/0.30mm 19.6 mm 120 mm² 630/0.50mm 21.7 mm 150 mm² 756/0.50mm 23.8 mm 185 mm² 924/0.50mm 26.4 mm 240 mm² 1190/0.50mm 29.6 mm 300 mm² 1491/0.50mm 32.7 mm 400 mm² 2016/0.50mm 36.6 mm 500 mm² 2520/0.50mm 41.9 mm 630 mm² 3304/0.50mm 45.6 mm PEKX01AA001JBAA PEKX02AA001JBAA PEKX03AA001JBAA PEKX04AA001JBAA PEKX05AA001JBAA PEKX06AA001JBAA PEKX07AA001JBAA PEKX08AA001JBAA PEKX09AA001JBAA PEKX10AA001JBAA PEKX11AA001JBAA PEKX68AA001JBAA PEKX69AA001JBAA PEKX70AA001JBAA PEKX71AA001JBAA OLX348/020-1CR OLX528/020-1CR OLX816/020-1CR OLX1179/020-1CR OLX696/030-1CR OLX972/030-1CR OLX1296/030-1CR OLX630/050-1CR OLX756/050-1CR OLX924/050-1CR OLX1190/050-1CR OLX1491/050-1CR OLX2016/050-1CR OLX2520/050-1CR OLX3304/050-1CR 20

23 Cable and Wires Single Core Cable Flexible, Low Smoke Zero Halogen Series or range: Versolex Flexible 1C Core colour: Natural XLPE Cable application: Welding Nominal voltage from to: kv Operating temperature, flexible: 110 C Halogen free: Yes Low smoke: Yes OLX528/020XLPE-EW Nominal cross section Number of strand and size Sheath colour Outer diameter approx. conductor 16 mm² 528/0.20mm Green-yellow 9.8 mm 25 mm² 816/0.20mm Black 11.3 mm 25 mm² 816/0.20mm Green-yellow 11.3 mm 35 mm² 1179/0.20mm Black 12.6 mm 35 mm² 1179/0.20mm Green-yellow 12.6 mm 50 mm² 696/0.30mm Black 14.2 mm 50 mm² 696/0.30mm Green-yellow 14.2 mm 70 mm² 972/0.30mm Black 16.2 mm 70 mm² 972/0.30mm Green-yellow 16.2 mm 95 mm² 1296/0.30mm Black 18.3 mm 95 mm² 1296/0.30mm Green-yellow 18.3 mm 120 mm² 630/0.50mm Black 20.7 mm 150 mm² 756/0.50mm Black 22.6 mm 185 mm² 924/0.50mm Black 24.6 mm 240 mm² 1190/0.50mm Black 27.7 mm 300 mm² 1491/0.50mm Black 31 mm 400 mm² 2016/0.50mm Black 35.4 mm 500 mm² 2520/0.50mm Black 40 mm 630 mm² 630/0.50mm Black 44 mm BZHX02AA001HTNA BZHX03AA001CXNA BZHX03AA001HTNA BZHX04AA001CXNA BZHX04AA001HTNA BZHX05AA001CXNA BZHX05AA001HTNA BZHX06AA001CXNA BZHX06AA001HTNA BZHX07AA001CXNA BZHX07AA001HTNA BZHE87AA001CXNA BZHE88AA001CXNA BZHE89AA001CXNA BZHE90AA001CXNA BZHE91AA001CXNA BZHE92AA001CXNA BZHE93AA001CXNA BZHE94AA001CXNA OLX528/020XLPE-EW OLX816/020XLPEBK OLX816/020XLPE-EW OLX1179/020XLPEBK OLX1179/020XLPE-EW OLX696/030XLPEBK OLX696/030XLPE-EW OLX972/030XLPEBK OLX972/030XLPE-EW OLX1296/030XLPEBK OLX1296/030XLPE-EW OLX630/050XLPEBK OLX756/050XLPEBK OLX924/050XLPEBK OLX1190/050XLPEBK OLX1491/050XLPEBK OLX2016/050XLPEBK OLX2520/050XLPEBK OLX3304/050XLPEBK 21

24 Cable and Wires Single Core Cable SDI, 1.0mm² Nominal cross section conductor: Number of strand and size: Sheath colour: Length: Outer diameter approx.: Double insulation: Voltage range: Solid 1 mm² 1C 1/1.13mm White 100 m 4 mm Yes 450/750 V OLX1/113-1R Core colour Red Black AABP02A1001WTRD AABP02A1001WTBK OLX1/113-1R OLX1/113-1BK SDI, 1.5mm² Nominal cross section conductor: Number of strand and size: Sheath colour: Length: Outer diameter approx.: Double insulation: Voltage range: Stranded 1.5 mm² 1C 7/0.50mm White 100 m 4.4 mm Yes 450/750 V OLX7/050-1BK Core colour Black Red White AABP05A1001WTBK AABP05A1001WTRD AABP05A1001WTWT OLX7/050-1BK OLX7/050-1R OLX7/050-1W 22

25 Cable and Wires Single Core Cable SDI, 2.5mm² Nominal cross section conductor: Number of strand and size: Sheath colour: Outer diameter approx.: Double insulation: Voltage range: Stranded 2.5 mm² 1C 7/0.67mm White 5.1 mm Yes 450/750 V OLX7/067-1BK Core colour Black Red Red White Length 100 m 100 m 500 m 100 m AABP07A1001WTBK AABP07A1001WTRD AABP07A5001WTRD AABP07A1001WTWT OLX7/067-1BK OLX7/067-1R OLX7/067-1RA5 OLX7/067-1W SDI, 4mm² Nominal cross section conductor: Number of strand and size: Sheath colour: Length: Outer diameter approx.: Double insulation: Voltage range: Stranded 4 mm² 1C 7/0.85mm White 100 m 6 mm Yes 450/750 V OLX7/085-1R Core colour Red Black AABP09A1001WTRD AABP09A1001WTBK OLX7/085-1R OLX7/085-1BK 23

26 Cable and Wires Single Core Cable SDI, 6mm² Nominal cross section conductor: Number of strand and size: Sheath colour: Outer diameter approx.: Double insulation: Voltage range: Stranded 6 mm² 1C 7/1.04mm White 6.6 mm Yes 450/750 V OLX7/104-1R Core colour Red Red Black Length 100 m 500 m 100 m AABP11A1001WTRD AABP11A5001WTRD AABP11A1001WTBK OLX7/104-1R OLX7/104-1RA5 OLX7/104-1BK SDI, 10mm² Nominal cross section conductor: Number of strand and size: Sheath colour: Outer diameter approx.: Double insulation: Voltage range: Stranded 10 mm² 1C 7/1.35mm White 7.8 mm Yes 450/750 V OLX7/135-1BK Core colour Black Black Red Red Length 100 m 500 m 100 m 500 m AABP13A1001WVBK AABP13A5001WVBK AABP13A1001WVRD AABP13A5001WVRD OLX7/135-1BK OLX7/135-1BKA5 OLX7/135-1R OLX7/135-1RA5 24

27 Cable and Wires Single Core Cable SDI, 16mm² Nominal cross section conductor: Number of strand and size: Sheath colour: Outer diameter approx.: Double insulation: Voltage range: Stranded 16 mm² 1C 7/1.70mm White 8.9 mm Yes 450/750 V OLX7/170-1BK Core colour Black Black Red Red Length 100 m 500 m 100 m 500 m AABP15A1001WVBK AABP15A5001WVBK AABP15A1001WVRD AABP15A5001WVRD OLX7/170-1BK OLX7/170-1BKA5 OLX7/170-1R OLX7/170-1RA5 Flexible: Versolex Series or range: Nominal voltage from to: Versolex Flexible 1C kv OLX19/135XLPEHD Nominal cross section conductor Number of strand and size Core colour Core insulation Sheath colour Length Outer diameter approx. 25 mm² 19/1.35mm Natural XLPE Orange 11.3 mm 35 mm² 285/0.40mm Natural XLPE Orange 500 m 12.6 mm 70 mm² 936/0.30mm Natural XLPE Green-yellow 16.2 mm 70 mm² 936/0.30mm Blue XLPE Blue 16.2 mm 70 mm² 936/0.30mm Red XLPE Red 16.2 mm 95 mm² 259/0.67mm Natural XLPE Orange 18.3 mm 150 mm² 735/0.50mm Blue XLPE Blue 100 m 22.6 mm 150 mm² 735/0.50mm Red XLPE Red 100 m 22.6 mm 150 mm² 735/0.50mm Natural Green-yellow 22.6 mm BDSX03AA001OMNA BDSX04A5001OMNA BDSX06AA001HTNA BDSX06AA001BFBE BDSX06AA001JBRD BDSX07AA001OMNA BDSE88A1001BFBE BDSE88A1001JBRD BAAE88AA001AAHT OLX19/135XLPEHD OLX285/040XLPEHD OLX936/030XLPE OLX936/030XLPEBE OLX936/030XLPERD OLX259/067XLPEHD OLX735/050XLPEHDBE OLX735/050XLPEHDRD OLX735/0501EC 25

28 Cable and Wires Single Core Cable XLPE, SDI, 16mm² Nominal cross section conductor: Number of strand and size: Core colour: Sheath colour: Outer diameter approx.: Double insulation: Nominal voltage from to: Stranded 16 mm² 1C 7/1.70mm Natural XLPE Black 9.3 mm Yes kv OLX7/170XLPEA1 Length 100 m 500 m BDBP15A1001CXNA BDBP15A5001CXNA BDBP15AA001CXNA OLX7/170XLPEA1 OLX7/170XLPEA5 OLX7/170XLPE XLPE, SDI, 25mm² Nominal cross section conductor: Number of strand and size: Core colour: Sheath colour: Outer diameter approx.: Double insulation: Nominal voltage from to: Compounded 25 mm² 1C 19/1.35mm Natural XLPE Black 10.5 mm Yes kv OLX19/135XLPE Length 500 m BDBC17AA001CXNA BDBC17A5001CXNA OLX19/135XLPE OLX19/135XLPEA5 26

29 Cable and Wires Single Core Cable XLPE, SDI, 35mm² Nominal cross section conductor: Core colour: Sheath colour: Outer diameter approx.: Double insulation: Nominal voltage from to: Compounded 35 mm² 1C Natural XLPE Black 11.5 mm Yes kv OLX19/153XLPE Number of strand and size 19/1.53mm 19/1.35mm Length 500 m BDBC18AA001CXNA BDBC18A5001CXNA OLX19/153XLPE OLX19/153XLPEA5 XLPE, SDI, 50mm² and Above Core colour: Sheath colour: Double insulation: Nominal voltage from to: 1C Natural XLPE Black Yes kv OLX19/178XLPE Conductor category Nominal cross section conductor Conductor material Number of strand and size Outer diameter approx. Compounded 50 mm² 19/1.78mm 12.9 mm Compounded 70 mm² 19/2.14mm 14.7 mm Compounded 95 mm² 37/1.78mm 17.2 mm Compounded 120 mm² 37/2.03mm 19.6 mm Compounded 150 mm² 37/2.25mm 21.3 mm Compounded 185 mm² 37/2.52mm 23.5 mm Compounded 240 mm² 61/2.25mm 26.6 mm Compounded 300 mm² 61/2.52mm 29.4 mm Compounded 300 mm² Aluminium 61/2.52mm 27.6 mm Stranded 400 mm² 61/2.85mm 33.3 mm Stranded 500 mm² 61/3.20mm 37 mm Stranded 630 mm² 127/2.52mm 41.4 mm BDBC19AA001CXNA BDBC20AA001CXNA BDBC22AA001CXNA BDBP23AA001CXNA BDBP24AA001CXNA BDBP25AA001CXNA BDBP26AA001CXNA BDBP27AA001CXNA BDBA27AA001CXNA BDBP28AA001CXNA BDBP30AA001CXNA BDBP32AA001CXNA OLX19/178XLPE OLX19/214XLPE OLX37/178XLPE OLX37/203XLPE OLX37/225XLPE OLX37/252XLPE OLX61/225XLPE OLX61/252XLPE OLX61/252AXLPE OLX61/285XLPE OLX61/320XLPE OLX127/252XLPE 27

30 Cable and Wires Single Core Cable Cable: Stranded Nominal cross section conductor: Number of strand and size: Stranded 120 mm² 1C 37/2.03mm OLX37/202-1CACU ACUP23AA001AAAA OLX37/202-1CACU Flat Cable Flat, 2C, 1.0mm² Nominal cross section conductor: Sheath material: Sheath colour: Number of strand and size: Length: Voltage range: 1 mm² Solid White 1/1.13mm 2C 100 m 450/750 V OLX1/113-2RB Core colour Red-black Red-white CACP02A1002WVAA CACP02A1002WVAB OLX1/113-2RB OLX1/113-2RW 28

31 Cable and Wires Flat Cable Flat, 2C+E, 1.0mm² Nominal cross section conductor: Sheath material: Sheath colour: Number of strand and size: Core colour: Voltage range: 1 mm² Solid White 1/1.13mm 2C+E Red black and earth 450/750 V OLX1/113-2ERB Length 100 m 200 m CNCP02A1002WVAA CNCP02A2002WVAA OLX1/113-2ERB OLX1/113-2ERBA2 Flat, 2C, 1.5mm² Nominal cross section conductor: Sheath material: Sheath colour: Number of strand and size: Voltage range: 1.5 mm² Stranded White 7/0.50mm 2C 450/750 V OLX7/050-2RB Length Core colour 100 m Red-black 100 m Red-white 500 m Red-white CACP05A1002WVAA CACP05A1002WVAB CACP05A5002WVAB OLX7/050-2RB OLX7/050-2RW OLX7/050-2RWA5 29

32 Cable and Wires Flat Cable Flat, 2C+E, 1.5mm² Nominal cross section conductor: Sheath material: Sheath colour: Number of strand and size: Core colour: Voltage range: 1.5 mm² Stranded White 7/0.50mm 2C+E Red black and earth 450/750 V OLX7/050-2ERB Length 100 m 500 m CNCP05A1002WVAA CNCP05A5002WVAA OLX7/050-2ERB OLX7/050-2ERBA5 Flat, 3C, 1.5mm² Nominal cross section conductor: Sheath material: Sheath colour: Length: Core colour: Voltage range: 1.5 mm² Stranded White 3C 100 m Red white and blue 450/750 V OLX7/050-3 EACP05A1003WVAA OLX7/

33 Cable and Wires Flat Cable Flat, 3C+E, 1.5mm² Nominal cross section conductor: Sheath material: Sheath colour: Number of strand and size: Length: Core colour: Voltage range: 1.5 mm² Stranded White 7/0.50mm 3C+E 100 m Red white and blue 450/750 V OLX7/050-3E ENCP05A1003WVAA OLX7/050-3E Flat, 2C, 2.5mm² Nominal cross section conductor: Sheath material: Sheath colour: Number of strand and size: Voltage range: 2.5 mm² Stranded White 7/0.67mm 2C 450/750 V OLX7/067-2RB Length Core colour 100 m Red-black 100 m Red-white 500 m Red-white CACP07A1002WVAA CACP07A1002WVAB CACP07A5002WVAB OLX7/067-2RB OLX7/067-2RW OLX7/067-2RWA5 31

34 Cable and Wires Flat Cable Flat, 2C+E, 2.5mm² Nominal cross section conductor: Sheath material: Number of strand and size: Core colour: Voltage range: 2.5 mm² Stranded 7/0.67mm 2C+E Red black and earth 450/750 V OLX7/067-2ERB Sheath colour White White Black White Black Length 100 m 500 m 100 m 150 m 500 m CNCP07A1002WVAA CNCP07A5002WVAA CNCP07A1002BKAA CNCP07A1502WVAA CNCP07A5002BKAA OLX7/067-2ERB OLX7/067-2ERBA5 OLX7/067-2ERBB OLX7/067-2ERB150 OLX7/067-2ERBBA5 Flat, 3C+E, 2.5mm² Nominal cross section conductor: Sheath material: Sheath colour: Number of strand and size: Length: Core colour: Voltage range: 2.5 mm² Stranded White 7/0.67mm 3C+E 100 m Red white and blue 450/750 V OLX7/067-3E ENCP07A1003WVAA OLX7/067-3E 32

35 Cable and Wires Flat Cable Flat, 2C, 4mm² Nominal cross section conductor: Sheath material: Sheath colour: Number of strand and size: Length: Voltage range: 4 mm² Stranded White 7/0.85mm 2C 100 m 450/750 V OLX7/085-2RB Core colour Red-black Red-white CACP09A1002WVAA CACP09A1002WVAB OLX7/085-2RB OLX7/085-2RW Flat, 2C+E, 4mm² Nominal cross section conductor: Sheath material: Number of strand and size: Core colour: Voltage range: 4 mm² Stranded 7/0.85mm 2C+E Red black and earth 450/750 V OLX7/085-2ERB Sheath colour White White Black Length 100 m 500 m 500 m CNCP09A1002WVAA CNCP09A5002WVAA CNCP09A5002BKAA OLX7/085-2ERB OLX7/085-2ERBA5 OLX7/085-2ECBKA5 33

36 Cable and Wires Flat Cable Flat, 2C, 6mm² Nominal cross section conductor: Sheath material: Sheath colour: Number of strand and size: Length: Voltage range: 6 mm² Stranded White 7/1.04mm 2C 100 m 450/750 V OLX7/104-2RB Core colour Red-black Red-white CACP11A1002WVAA CACP11AA002WVAB OLX7/104-2RB OLX7/104-2RW Flat, 2C+E, 6mm² Nominal cross section conductor: Sheath material: Sheath colour: Number of strand and size: Core colour: Voltage range: 6 mm² Stranded White 7/1.04mm 2C+E Red black and earth 450/750 V OLX7/104-2ERB Length 100 m 500 m CNCP11A1002WVAA CNCP11A5002WVAA OLX7/104-2ERB OLX7/104-2ERBA5 34

37 Cable and Wires Flat Cable Flat, 2C, 10mm² Nominal cross section conductor: Sheath material: Number of strand and size: Length: Core colour: Voltage range: 10 mm² Stranded 7/1.35mm 2C 100 m Red-black 450/750 V OLX7/135-2RB Sheath colour White Orange CACP13A1002WVAA CACP13A1002OGAA OLX7/135-2RB OLX7/135-2RBOR Flat, 2C+E, 10mm² Nominal cross section conductor: Sheath material: Sheath colour: Number of strand and size: Core colour: Voltage range: 10 mm² Stranded White 7/1.35mm 2C+E Red black and earth 450/750 V OLX7/135-2ERB Length 100 m 500 m CNCP13A1002WVAA CNCP13A5002WVAA OLX7/135-2ERB OLX7/135-2ERBA5 35

38 Cable and Wires Flat Cable Flat, 2C, 16mm² Nominal cross section conductor: Sheath material: Number of strand and size: Core colour: Voltage range: 16 mm² Stranded 7/1.70mm 2C Red-black 450/750 V OLX7/170-2RB Sheath colour White White Orange Orange Length 100 m 500 m 100 m 500 m CACP15A1002WVAA CACP15A5002WVAA CACP15A1002OGAA CACP15A5002OGAA OLX7/170-2RB OLX7/170-2RBA5 OLX7/170-2RBOR OLX7/170-2RBORA5 Flat, 2C+E, 16mm² Nominal cross section conductor: Sheath material: Sheath colour: Number of strand and size: Core colour: Voltage range: 16 mm² Stranded White 7/1.70mm 2C+E Red black and earth 450/750 V OLX7/170-2ERB Length 100 m 500 m CNCP15A1002WVAA CNCP15A5002WVAA OLX7/170-2ERB OLX7/170-2ERBA5 36

39 Cable and Wires Flat Cable Cable, Fire Alarm Flat 2C, 1.5mm² Nominal cross section conductor: Sheath material: Sheath colour: Cable application: Number of strand and size: Core colour: Voltage range: 1.5 mm² Stranded Red Fire alarm 7/0.50mm 2C Red-white 450/750 V OLX7/050-2AR Length 100 m 500 m 200 m CACP05A1002RDAB CACP05A5002RDAB CACP05A2002RDAB OLX7/050-2AR OLX7/050-2ARA5 OLX7/050-2ARA2 Low Voltage Multi Core Cable Cable Flexible: Titanex Series or range: Sheath material: Nominal voltage from to: Titanex Rubber kv OLX30/025-2EC Nominal cross section conductor Number of cores 1.5 mm² 2C+E 2.5 mm² 2C+E 2.5 mm² 3C+E 2.5 mm² 4C+E 4 mm² 2C+E 4 mm² 3C+E 4 mm² 4C+E 6 mm² 3C+E 6 mm² 4C+E 16 mm² 3C+E 25 mm² 3C+E HAR3G1.5 HAR3G2.5 HAR4G2.5 HAR5G2.5 HAR3G4 HAR4G4 HAR5G4 HAR4G6 HAR5G6 HAR4G16 HAR4G25 OLX30/025-2EC OLX50/025-2EC OLX50/025-3EC OLX50/025-4EC OLX56/030-2EC OLX56/030-3EC OLX56/030-4EC OLX84/030-3EC OLX84/030-4EC OLX128/040-3EC OLX200/040-3EC 37

40 Cable and Wires Low Voltage Multi Core Cable Circ, Orange, 2C+E, 1.5mm² to 4mm² (450/750V) Sheath colour: Sheath material: Conductor shape: Voltage range: Stranded Orange 2C+E Circular 450/750 V OLX7/050-2ECA1 Nominal cross section conductor Outer diameter approx Number of strand and size Length 1.5 mm² 8.4 mm 7/0.50mm 100 m 1.5 mm² 8.4 mm 7/0.50mm 500 m 2.5 mm² 9.8 mm 7/0.67mm 100 m 2.5 mm² 9.8 mm 7/0.67mm 500 m 4 mm² 11.4 mm 7/0.85mm 4 mm² 11.4 mm 7/0.85mm 100 m 4 mm² 11.4 mm 7/0.85mm 500 m CNHP05A1002OMAA CNHP05A5002OMAA CNHP07A1002OMAA CNHP07A5002OMAA CNHP09AA002OMAA CNHP09A1002OMAA CNHP09A5002OMAA OLX7/050-2ECA1 OLX7/050-2ECA5 OLX7/067-2ECA1 OLX7/067-2ECA5 OLX7/085-2EC OLX7/085-2ECA1 OLX7/085-2ECA5 Circ, Orange, Black 2C+E, 1.5mm² to 4mm² (0.6/1KV) Sheath material: Nominal voltage from to: Conductor shape: Stranded kv 2C+E Circular OLX7/050-2ECCBK Sheath colour Nominal cross section conductor Number of strand and size Black 1.5 mm² 7/0.50mm Orange 1.5 mm² 7/0.50mm Orange 2.5 mm² 7/0.67mm Orange 4 mm² 7/0.85mm DNHP05AA002CXWW DNHP05AA002OMWW DNHP07AA002OMAA DNHP09AA002OMAA OLX7/050-2ECCBK OLX7/050-2ECC.6/1KV OLX7/067-2EC.6/1KV OLX7/085-2EC.6/1KV 38

41 Cable and Wires Low Voltage Multi Core Cable Circ, Orange, 2C+E, 6mm² (450/750V) Sheath colour: Sheath material: Nominal cross section conductor: Outer diameter approx: Number of strand and size: Conductor shape: Voltage range: Stranded Orange 6 mm² 12.4 mm 7/1.04mm 2C+E Circular 450/750 V OLX7/104-2EC Length 100 m 500 m CNHP11AA002OMAA CNHP11A1002OMAA CNHP11A5002OMAA OLX7/104-2EC OLX7/104-2ECA1 OLX7/104-2ECA5 Circ, Orange, 2C+E, 6mm² to 35mm² (0.6/1KV) Sheath colour: Sheath material: Nominal voltage from to: Conductor shape: Orange kv 2C+E Circular OLX7/104-2EC.6/1KV Conductor category Nominal cross section conductor Outer diameter approx Number of strand and size Length Stranded 6 mm² 12.4 mm 7/1.04mm Stranded 10 mm² 16.1 mm 7/1.35mm Stranded 10 mm² 16.1 mm 7/1.35mm 100 m Stranded 10 mm² 16.1 mm 7/1.35mm 500 m Stranded 16 mm² 16.1 mm 7/1.70mm Stranded 16 mm² 18 mm 7/1.70mm 500 m Compounded 25 mm² 20.5 mm 19/1.35mm Compounded 25 mm² 20.5 mm 19/1.35mm 500 m Compounded 35 mm² 22.5 mm 19/1.53mm DNHP11AA002OMAA DNHP13AA002OMAA DNHP13A1002OMAA DNHP13A5002OMAA DNHP15AA002OMAA DNHP15A5002OMAA DNHC17AA002OMAA DNHC17A5002OMAA DNHC18AA002OMAA OLX7/104-2EC.6/1KV OLX7/135-2EC OLX7/135-2ECA1 OLX7/135-2ECA5 OLX7/170-2EC OLX7/170-2ECA5 OLX19/135-2EC OLX19/135-2ECA5 OLX19/153-2EC 39

42 Cable and Wires Low Voltage Multi Core Cable Circ, Orange, 3C+E, 1.5mm² to 2.5mm² (450/750V) Sheath colour: Sheath material: Conductor shape: Voltage range: Stranded Orange 3C+E Circular 450/750 V OLX7/050-3ECA1 Nominal cross section conductor Outer diameter approx Number of strand and size Length 1.5 mm² 8.4 mm 7/0.50mm 100 m 1.5 mm² 9.2 mm 7/0.50mm 500 m 2.5 mm² 11.1 mm 7/0.67mm 2.5 mm² 11.1 mm 7/0.67mm 100 m 2.5 mm² 11.1 mm 7/0.67mm 500 m ENHP05A1003OMAA ENHP05A5003OMAA ENHP07AA003OMAA ENHP07A1003OMAA ENHP07A5003OMAA OLX7/050-3ECA1 OLX7/050-3ECA5 OLX7/067-3EC OLX7/067-3ECA1 OLX7/067-3ECA5 Circ, Orange, 3C+E, 2.5mm² (0.6/1KV) Sheath colour: Sheath material: Nominal cross section conductor: Nominal voltage from to: Number of strand and size: Conductor shape: Stranded Orange 2.5 mm² kv 7/0.67mm 3C+E Circular OLX7/067-3EC.6/1KV FNHP07AA003OMAA OLX7/067-3EC.6/1KV 40

43 Cable and Wires Low Voltage Multi Core Cable Circ, Orange 3C+E, 4mm² to 6mm² (450/750V) Sheath colour: Sheath material: Conductor shape: Voltage range: Stranded Orange 3C+E Circular 450/750 V OLX7/085-3EC Nominal cross section conductor Outer diameter approx Number of strand and size Length 4 mm² 12.5 mm 7/0.85mm 4 mm² 12.5 mm 7/0.85mm 500 m 6 mm² 13.5 mm 7/1.04mm 6 mm² 13.5 mm 7/1.04mm 100 m 6 mm² 13.5 mm 7/1.04mm 500 m ENHP09AA003OMAA ENHP09A5003OMAA ENHP11AA003OMAA ENHP11A1003OMAA ENHP11A5003OMAA OLX7/085-3EC OLX7/085-3ECA5 OLX7/104-3EC OLX7/104-3ECA1 OLX7/104-3ECA5 Circ, Orange 3C+E, 4mm² to 70mm² (0.6/1KV) Sheath colour: Sheath material: Nominal voltage from to: Conductor shape: Orange kv 3C+E Circular OLX7/085-3EC.6/1KV Conductor category Nominal cross section conductor Outer diameter approx Number of strand and size Length Stranded 4 mm² 12.5 mm 7/0.85mm Stranded 6 mm² 13.5 mm 7/1.04mm Stranded 10 mm² 17.5 mm 7/1.35mm Stranded 10 mm² 17.5 mm 7/1.35mm 500 m Stranded 16 mm² 19.6 mm 7/1.70mm Stranded 16 mm² 19.6 mm 7/1.70mm 500 m Compounded 25 mm² 22.2 mm 19/1.35mm Compounded 35 mm² 24.6 mm 19/1.53mm Compounded 50 mm² 28 mm 19/1.78mm Compounded 70 mm² 32 mm 19/2.14mm FNHP09AA003OMAA FNHP11AA003OMAA FNHP13AA003OMAA FNHP13A5003OMAA FNHP15AA003OMAA FNHP15A5003OMAA FNHC17AA003OMAA FNHC18AA003OMAA FNHC19AA003OMAA FNHC20AA003OMAA OLX7/085-3EC.6/1KV OLX7/104-3EC.6/1KV OLX7/135-3EC OLX7/135-3ECA5 OLX7/170-3EC OLX7/170-3ECA5 OLX19/135-3EC OLX19/153-3EC OLX19/178-3EC OLX19/214-3EC 41

44 Cable and Wires Low Voltage Multi Core Cable Circ, Orange 4C+E, 1.5mm² to 2.5mm² (450/750V) Sheath colour: Sheath material: Conductor shape: Voltage range: Stranded Orange 4C+E Circular 450/750 V OLX7/050-4EC Nominal cross section conductor Outer diameter approx Number of strand and size Length 1.5 mm² 10 mm 7/0.50mm 1.5 mm² 10 mm 7/0.50mm 100 m 1.5 mm² 10 mm 7/0.50mm 500 m 1.5 mm² 10 mm 7/0.50mm 2.5 mm² 12 mm 7/0.67mm 2.5 mm² 12 mm 7/0.67mm 100 m 2.5 mm² 12 mm 7/0.67mm 500 m GNHP05AA004OMAA GNHP05A1004OMAA GNHP05A5004OMAA GNHP05A9004OMWW GNHP07AA004OMAA GNHP07A1004OMAA GNHP07A5004OMAA OLX7/050-4EC OLX7/050-4ECA1 OLX7/050-4ECA5 OLX7/050-4ECCA9 OLX7/067-4EC OLX7/067-4ECA1 OLX7/067-4ECA5 Circ, Orange 4C+E, 1.5mm² to 2.5mm² (0.6/1KV) Sheath material: Nominal voltage from to: Conductor shape: Stranded kv 4C+E Circular OLX7/050-4ECC.6/1KV Sheath colour Nominal cross section conductor Number of strand and size Orange 1.5 mm² 7/0.50mm Black 2.5 mm² 7/0.67mm Orange 2.5 mm² 7/0.67mm HNHP05AA004OMWW HNHP07AA004CXWW HNHP07AA004OMAA OLX7/050-4ECC.6/1KV OLX7/067-4ECCBK OLX7/067-4ECCO 42

45 Cable and Wires Low Voltage Multi Core Cable Circ, Black 4C+E, 1.5mm² (0.6/1KV) Sheath colour: Sheath material: Nominal cross section conductor: Nominal voltage from to: Conductor shape: Stranded Black 1.5 mm² kv 4C+E Circular OLX7/050-4ECCBK HNHP05AA004CXWW OLX7/050-4ECCBK Circ, Orange 4C+E, 4mm² to 6mm² (450/750V) Sheath colour: Sheath material: Conductor shape: Voltage range: Stranded Orange 4C+E Circular 450/750 V OLX7/085-4EC Nominal cross section conductor Outer diameter approx Number of strand and size Length 4 mm² 13.8 mm 7/0.85mm 4 mm² 13.8 mm 7/0.85mm 100 m 4 mm² 13.8 mm 7/0.85mm 500 m 6 mm² 15 mm 7/1.04mm 6 mm² 15 mm 7/1.04mm 100 m 6 mm² 15 mm 7/1.04mm 500 m GNHP09AA004OMAA GNHP09A1004OMAA GNHP09A5004OMAA GNHP11AA004OMAA GNHP11A1004OMAA GNHP11A5004OMAA OLX7/085-4EC OLX7/085-4ECA1 OLX7/085-4ECA5 OLX7/104-4EC OLX7/104-4ECA1 OLX7/104-4ECA5 43

46 Cable and Wires Low Voltage Multi Core Cable Circ, Orange 4C+E, 4mm² to 16mm² (0.6/1KV) Sheath colour: Sheath material: Nominal voltage from to: Conductor shape: Stranded Orange kv 4C+E Circular OLX7/085-4EC.6/1KV Nominal cross section conductor Outer diameter approx Number of strand and size Length 4 mm² 13.8 mm 7/0.85mm 6 mm² 15 mm 7/1.04mm 10 mm² 19.2 mm 7/1.35mm 10 mm² 19.2 mm 7/1.35mm 100 m 10 mm² 19.2 mm 7/1.35mm 500 m 16 mm² 21.5 mm 7/1.70mm 16 mm² 21.5 mm 7/1.70mm 100 m 16 mm² 21.5 mm 7/1.70mm 500 m HNHP09AA004OMAA HNHP11AA004OMAA HNHP13AA004OMAA HNHP13A1004OMAA HNHP13A5004OMAA HNHP15AA004OMAA HNHP15A1004OMAA HNHP15A5004OMAA OLX7/085-4EC.6/1KV OLX7/104-4EC.6/1KV OLX7/135-4EC OLX7/135-4ECA1 OLX7/135-4ECA5 OLX7/170-4EC OLX7/170-4ECA1 OLX7/170-4ECA5 Circ, Orange 4C+E, 25mm² to 120mm² (0.6/1KV) Sheath colour: Sheath material: Nominal voltage from to: Conductor shape: Orange kv 4C+E Circular OLX19/135-4EC Conductor category Nominal cross section conductor Outer diameter approx Number of strand and size Length Compounded 25 mm² 24.5 mm 19/1.35mm Compounded 25 mm² 24.5 mm 19/1.35mm 500 m Compounded 35 mm² 27.2 mm 19/1.35mm Compounded 35 mm² 27.2 mm 19/1.53mm 500 m Compounded 50 mm² 31.2 mm 19/1.78mm Compounded 70 mm² 35.8 mm 19/2.14mm Compounded 95 mm² 42 mm 37/1.78mm Stranded 120 mm² 47.5 mm 37/2.03mm HNHC17AA004OMAA HNHC17A5004OMAA HNHC18AA004OMAA HNHC18A5004OMAA HNHC19AA004OMAA HNHC20AA004OMAA HNHC22AA004OMAA HNHP23AA004OMAA OLX19/135-4EC OLX19/135-4ECA5 OLX19/153-4EC OLX19/153-4ECA5 OLX19/178-4EC OLX19/214-4EC OLX37/178-4EC OLX37/203-4EC 44

47 Cable and Wires Low Voltage Multi Core Cable Flex,, MultiCore O/DTY Duty type: Sheath colour: Sheath material: Length: Flexible Ordinary duty Grey 2C+E 100 m OLX32/020-3GY Nominal cross section Outer diameter approx Number of strand and size Voltage range conductor 1 mm² 6.9 mm 32/0.20mm V 1.5 mm² 8.1 mm 30/0.25mm V 2.5 mm² 9.9 mm 50/0.25mm V EAHR03A1003GYAA EAHR04A1003GYAA EAHR05A1003GYAA OLX32/020-3GY OLX30/025-3GY OLX50/025-3GY Flex,, MultiCore H/DTY Duty type: Sheath colour: Sheath material: Nominal cross section conductor: Nominal voltage from to: Outer diameter approx: Number of strand and size: Length: Flexible Heavy duty Orange 1.5 mm² kv 9.9 mm 30/0.25mm 2C+E 100 m OLX30/025H3O EBGR04A1003OGAA OLX30/025H3O 45

48 Cable and Wires Low Voltage Multi Core Cable SWA, 1.5mm² to 16mm² Sheath colour: Sheath material: Nominal voltage from to: Armouring: Conductor shape: Stranded Orange kv Yes Circular OLX7/050-2ECSWA.6/1KV Nominal cross section Outer diameter approx Number of strand and size Number of cores conductor 1.5 mm² 14.1 mm 7/0.50mm 2C+E 1.5 mm² 15 mm 7/0.50mm 3C+E 1.5 mm² 15.9 mm 7/0.50mm 4C+E 2.5 mm² 15.2 mm 7/0.67mm 2C+E 2.5 mm² 15.2 mm 7/0.67mm 2C+E 2.5 mm² 16.3 mm 7/0.67mm 3C+E 4 mm² 16.9 mm 7/0.85mm 2C+E 4 mm² 20 mm 7/0.85mm 4C+E 6 mm² 18.1 mm 7/1.04mm 2C+E 6 mm² 20 mm 7/1.04mm 3C+E 6 mm² 21.4 mm 7/1.04mm 4C+E 10 mm² 16.1 mm 7/1.35mm 2C+E 10 mm² 22.1 mm 7/1.35mm 3C+E 10 mm² 19.2 mm 7/1.35mm 4C+E 16 mm² 22.5 mm 7/1.70mm 2C+E 16 mm² 24.9 mm 7/1.70mm 3C+E 16 mm² 26.8 mm 7/1.70mm 4C+E DNMP05AA002OMAA FNMP05AA003OMAA HNMP05AA004OMAA DNMP07A5002OMAA DNMP07AA002OMAA FNMP07AA003OMAA DNMP09AA002OMAA HNMP09AA004OMAA DNMP11AA002OMAA FNMP11AA003OMAA HNMP11AA004OMAA DNMP13AA002OMAA FNMP13AA003OMAA HNMP13AA004OMAA DNMP15AA002OMAA FNMP15AA003OMAA HNMP15AA004OMAA OLX7/050-2ECSWA.6/1KV OLX7/050-3ECSWA.6/1KV OLX7/050-4ECSWA.6/1KV OLX7/067-2ECSWA OLX7/067-2ECSWA.6/1KV OLX7/067-3ECSWA.6/1KV OLX7/085-2ECSWA.6/1KV OLX7/085-4ECSWA.6/1KV OLX7/104-2ECSWA.6/1KV OLX7/104-3ECSWA.6/1KV OLX7/104-4ECSWA.6/1KV OLX7/135-2SWA OLX7/135-3SWA OLX7/135-4SWA OLX7/170-2SWA OLX7/170-3SWA OLX7/170-4SWA 46

49 Cable and Wires Low Voltage Multi Core Cable SWA, 25mm² to 240mm² Sheath colour: Sheath material: Nominal voltage from to: Armouring: Conductor shape: Orange kv Yes Circular OLX19/135-3SWA Conductor category Nominal cross section conductor Core insulation Outer diameter approx Number of strand and size Number of cores Compounded 25 mm² 27.5 mm 19/1.35mm 3C+E Compounded 25 mm² 29.8 mm 19/1.35mm 4C+E Compounded 35 mm² 29.9 mm 19/1.53mm 3C+E Compounded 35 mm² XLPE 28.4 mm 19/1.53mm 3C+E Compounded 50 mm² 33.7 mm 19/1.78mm 3C+E Compounded 50 mm² 33.7 mm 19/1.78mm 3C+E Compounded 50 mm² 38.1 mm 19/1.78mm 4C+E Compounded 50 mm² XLPE 31.8 mm 19/1.78mm 3C+E Compounded 70 mm² 44.3 mm 19/2.14mm 3C+E Compounded 70 mm² 42.5 mm 19/2.14mm 4C+E Compounded 70 mm² XLPE 37.4 mm 19/2.14mm 3C+E Compounded 95 mm² 44.3 mm 37/1.78mm 3C+E Compounded 95 mm² XLPE 42.1 mm 37/1.78mm 3C+E Compounded 95 mm² 48.8 mm 37/1.78mm 4C+E Stranded 120 mm² 49.2 mm 37/2.03mm 3C+E Stranded 120 mm² XLPE 47.2 mm 37/2.03mm 3C+E Stranded 150 mm² 54.5 mm 37/2.25mm 3C+E Stranded 150 mm² XLPE 52.6 mm 37/2.25mm 3C+E Stranded 185 mm² 60.1 mm 37/2.52mm 3C+E Stranded 185 mm² XLPE 58 mm 37/2.52mm 3C+E Compounded 240 mm² XLPE 73 mm 61/2.25mm 4C+E FNMC17AA003OMAA HNMC17AA004OMAA FNMC18AA003OMAA FTMC18AA003OMRJ FNMC19AA003OMAA FNMC19DR003OMAA HNMC19AA004OMAA FTMC19AA003OMRJ FNMC20AA003OMAA HNMC20AA004OMAA FTMC20AA003OMRJ FNMC22AA003OMAA FTMC22AA003OMRJ HNMC22AA004OMAA FNMP23AA003OMAA FTMP23AA003OMRJ FNMP24AA003OMAA FTMP24AA003OMRJ FNMP25AA003OMAA FTMP25AA003OMRJ HTMP26AA004OMEM OLX19/135-3SWA OLX19/135-4SWA OLX19/153-3SWA OLX18/170-3ECSWAXLPE OLX19/178-3SWA OLX19/178-3CSWA OLX19/178-4SWA OLX18/195-3ECSWAXLPE OLX19/214-3SWA OLX19/214-4SWA OLX18/235-3ECSWAXLPE OLX37/178-3SWA OLX18/252-3ECSWAXLPE OLX37/178-4SWA OLX37/203-3SWA OLX37/203-3ECSWAXLPE OLX37/225-3SWA OLX37/225-3ECSWAXLPE OLX37/252-3SWA OLX37/252-3ECSWAXLPE OLX37/252-4ECSWAXLPE 47

50 Cable and Wires Low Voltage Multi Core Cable XLPE,, Multicore Sheath material: Nominal voltage from to: Conductor shape: XLPE kv Circular OLX18/170-3ECXLPE Conductor category Sheath colour Nominal cross section conductor Outer diameter approx Compounded Orange 35 mm² 23.2 mm 3C+E Compounded Orange 50 mm² 26.3 mm 3C+E Compounded Orange 70 mm² 30.5 mm 3C+E Compounded Orange 95 mm² 35.2 mm 3C+E Stranded Orange 120 mm² 40.3 mm 3C+E Stranded Orange 150 mm² 44.3 mm 3C+E Stranded Orange 185 mm² 49.7 mm 3C+E Compounded Orange 25 mm² 22.9 mm 4C+E Compounded Black 35 mm² 27.9 mm 4C Compounded Orange 35 mm² 25.5 mm 4C+E Compounded Orange 50 mm² 29.3 mm 4C+E Compounded Orange 70 mm² 34 mm 4C+E Compounded Orange 95 mm² 39.3 mm 4C+E Stranded Orange 120 mm² 45.2 mm 4C+E Stranded Orange 150 mm² 49.5 mm 4C+E Stranded Orange 185 mm² 55.7 mm 4C+E Compounded Orange 240 mm² 63.5 mm 4C+E Number of cores FTHC18AA003OMAA FTHC19AA003OMAA FTHC20AA003OMAA FTHC22AA003OMAA FTHP23AA003OMAA FTHP24AA003OMAA FTHP25AA003OMAA HTHC17AA004OMAA HEVC18SJ004CXEM HTHC18AA004OMAA HTHC19AA004OMAA HTHC20AA004OMAA HTHC22AA004OMAA HTHP23AA004OMAA HTHP24AA004OMEM HTHP25AA004OMAA HTHP26AA004OMAA OLX18/170-3ECXLPE OLX18/195-3ECXLPE OLX18/235-3ECXLPE OLX19/252-3ECXLPE OLX37/203-3ECXLPE OLX37/225-3ECXLPE OLX37/252-3ECXLPE OLX18/147-4ECXLPE OLX18/170-4CXLPEURD OLX18/170-4ECXLPE OLX18/195-4ECXLPE OLX18/235-4ECXLPE OLX19/252-4ECXLPE OLX37/203-4ECXLPE OLX37/225-4ECXLPE OLX37/252-4ECXLPE OLX37/288-4ECXLPE 48

51 Cable and Wires Low Voltage Multi Core Cable Varolex, Circ 2.5mm² to 240mm² Series or range: Sheath colour: Nominal voltage from to: Conductor shape: Varolex Black XLPE kv 3C+E Circular OLX7/067-3ECVA Conductor category Nominal cross section Outer diameter approx Number of strand and size conductor Stranded 2.5 mm² 14.6 mm 7/0.67mm Stranded 10 mm² 18.5 mm 7/1.35mm Compounded 25 mm² 22.8 mm 19/1.35mm Compounded 35 mm² 25.6 mm 19/1.53mm Compounded 50 mm² 28.8 mm 19/1.78mm Compounded 70 mm² 32 mm 19/2.14mm Compounded 95 mm² 38 mm 37/1.78mm Stranded 120 mm² 43.2 mm 37/2.03mm Stranded 150 mm² 47.3 mm 37/2.25mm Stranded 185 mm² 52 mm 37/2.52mm Compounded 240 mm² 58.9 mm 61/2.25mm FTDP07AA003CXRJ FTDP13AA003CXRJ FTDC17AA003CXRJ FTDC18AA003CXRJ FTDC19AA003CXRJ FTDC20AA003CXRJ FTDC22AA003CXRJ FTDP23AA003CXRJ FTDP24AA003CXRJ FTDP25AA003CXRJ FTDP26AA003CXRJ OLX7/067-3ECVA OLX7/135-3ECVA OLX19/135-3ECVA OLX19/153-3ECVA OLX19/178-3ECVA OLX19/214-3ECVA OLX37/178-3ECVA OLX37/203-3ECVA OLX37/225-3ECVA OLX37/252-3ECVA OLX37/288-3ECVA 49

52 Cable and Wires Low Voltage Multi Core Cable Cable, Fire Rated Multicore Series or range: Pyrolex ceramifiable Sheath colour: Red Operating temperature: C Nominal voltage from to: kv Halogen free: Yes Low smoke: Yes OLX46/020-2ECR Nominal cross section Outer diameter approx Number of strand and size Number of cores conductor 1.5 mm² 11.8 mm 46/0.20mm 2C+E 1.5 mm² 12.8 mm 46/0.20mm 3C+E 1.5 mm² 14 mm 46/0.20mm 4C+E 2.5 mm² 13 mm 76/0.20mm 2C+E 2.5 mm² 14 mm 76/0.20mm 3C+E 2.5 mm² 13.8 mm 76/0.20mm 4C+E 4 mm² 13.8 mm 56/0.30mm 2C+E 4 mm² 15 mm 56/0.30mm 3C+E 4 mm² 13.8 mm 56/0.30mm 4C+E 6 mm² 14.7 mm 81/0.30mm 2C+E 6 mm² 16 mm 81/0.30mm 3C+E 6 mm² 17.6 mm 81/0.30mm 4C+E 10 mm² 16.3 mm 348/0.20mm 2C+E 10 mm² 17.9 mm 348/0.20mm 3C+E 10 mm² 19.7 mm 348/0.20mm 4C+E 16 mm² 20.1 mm 528/0.20mm 2C+E 16 mm² 20.1 mm 528/0.20mm 3C+E 16 mm² 22.2 mm 528/0.20mm 4C+E 25 mm² 25 mm 816/0.20mm 4C+E 35 mm² 28 mm 1179/0.20mm 4C+E 50 mm² 32.3 mm 696/0.30mm 4C+E 0.75 mm² 10.6 mm 24/0.20mm 2C 0.75 mm² 11.1 mm 24/0.20mm 3C 0.75 mm² 12 mm 24/0.20mm 4C 1 mm² 10.7 mm 32/0.20mm 2C 1 mm² 11.2 mm 32/0.20mm 3C 1 mm² 12.1 mm 32/0.20mm 4C 1.5 mm² 11.3 mm 46/0.20mm 2C 1.5 mm² 11.8 mm 46/0.20mm 3C 1.5 mm² 12.7 mm 46/0.20mm 4C 2.5 mm² 13 mm 76/0.20mm 2C 2.5 mm² 12.3 mm 76/0.20mm 4C PDKP05AA002JBAA PDKP05AA003JBAA PDKP05AA004JBAA PDKP07AA002JBAA PDKP07AA003JBAA PDKP07AA004JBAA PDKP09AA002JBAA PDKP09AA003JBAA PDKP09AA004JBAA PDKP11AA002JBAA PDKP11AA003JBAA PDKP11AA004JBAA PDKP13AA002JBAA PDKP13AA003JBAA PDKP13AA004JBAA PDKP15AA002JBAA PDKP15AA003JBAA PDKP15AA004JBAA PDKP17AA004JBAA PDKP18AA004JBAA PDKP19AA004JBAA PEKE99AA002JBAA PEKE99AA003JBAA PEKE99AA004JBAA PEKP03AA002JBAA PEKP03AA003JBAA PEKP03AA004JBAA PEKP05AA002JBAA PEKP05AA003JBAA PEKP05AA004JBAA PEKP07AA002JBAA PEKP07AA004JBAA OLX46/020-2ECR OLX46/020-3ECR OLX46/020-4ECR OLX76/020-2ECR OLX76/020-3ECR OLX76/020-4ECR OLX56/030-2ECR OLX56/030-3ECR OLX56/030-4ECR OLX81/030-2ECR OLX81/030-3ECR OLX81/030-4ECR OLX348/020-2ECR OLX348/020-3ECR OLX348/020-4ECR OLX528/020-2ECR OLX528/020-3ECR OLX528/020-4ECR OLX816/020-4ECR OLX1179/020-4ECR OLX696/030-4ECR OLX24/020-2CR0.6/1KV OLX24/020-3CR OLX24/020-4CR0.6/1KV OLX32/020-2CR OLX32/020-3CR OLX32/020-4CR OLX46/020-2CR0.6/1KV OLX46/020-3CR OLX46/020-4CR OLX76/020-2CR OLX76/020-4CR 50

53 Cable and Wires Low Voltage Multi Core Cable Cable, Fire Alarm Round 2C, 1.5mm² Sheath colour: Nominal cross section conductor: Outer diameter approx: Screen: Cable application: Number of strand and size: Length: Red 1.5 mm² 7 mm No Fire alarm 7/0.50mm 2C 500 m OLXJRS1502A5 JRS1502A5 OLXJRS1502A5 Cable: Mains Sheath colour: Nominal cross section conductor: Screen: Number of strand and size: Black 16 mm² Yes 7/1.70mm 2C OLX7/170NS2 BAGP15AA001CXAA OLX7/170NS2 51

54 Cable and Wires Low Voltage Multi Core Cable Cable:Underground Residential Distribution Sheath colour: Sheath material: Nominal cross section conductor: Nominal voltage from to: Outer diameter approx: Number of strand and size: Black 16 mm² XLPE kv 22.1 mm 7/1.70mm 4C OLX7/170-4 HEVP15AA004CXEM HEVP15A3004CXEM OLX7/170-4 OLX7/170-4CXLPEURD Cable: Mining Sheath colour: Sheath material: Nominal voltage from to: Screen: Cable application: Black Rubber (EPR) Rubber (EPR) kv Yes Mining 3C OLX285/040-3C Nominal cross section conductor 35 mm² 50 mm² MEGR61AA003BKAA MEGR62AA003BKAA OLX285/040-3C OLX380/040-3C 52

55 Cable and Wires High Voltage Power Cable Cable: High Voltage 70mm² & 95mm² 3 XLPE Sheath material: Nominal voltage from to: kv Screened: Yes OLX19/214-3CSWAHVRD Nominal cross section conductor Sheath colour 70 mm² Black 95 mm² Red XJJP20AA003JBAA XJJP22AA003JBAA OLX19/214-3CSWAHVRD OLX37/178-3CSWAXLPEHVRD Control Cable Circ, Control, 6 to 12 Core Core identification: Sheath material: Sheath colour: Conductor shape: Nominal voltage from to: Stranded Numbers Black Circular kv OLX7/050-6EC Nominal cross section conductor Outer diameter approx. Number of strand and size Number of cores Length 1.5 mm² 13.1 mm 7/0.50mm 6C+E 100 m 1.5 mm² 13.1 mm 7/0.50mm 6C+E 500 m 1.5 mm² 15.4 mm 7/0.50mm 8C+E 100 m 1.5 mm² 16.1 mm 7/0.50mm 10C+E 100 m 1.5 mm² 17 mm 7/0.50mm 12C+E 100 m 2.5 mm² 14.6 mm 7/0.67mm 6C+E 100 m 2.5 mm² 18.1 mm 7/0.67mm 10C+E 100 m BFAP05AA006CXWW BFAP05A5006CXWW BFAP05AA008CXWW BFAP05AA010CXWW BFAP05AA012CXWW BFAP07AA006CXWW BFAP07AA010CXWW OLX7/050-6EC OLX7/050-6ECA5 OLX7/050-8ECBK OLX7/050-10EC OLX7/050-12EC OLX7/067-6EC OLX7/067-10EC 53

56 Cable and Wires Control Cable Circ, Control, 20 to 50 Core Core identification: Nominal cross section conductor: Sheath material: Sheath colour: Number of strand and size: Conductor shape: Length: Nominal voltage from to: Stranded Numbers 1.5 mm² Black 7/0.50mm Circular 100 m kv OLX7/050-20ECBK Outer diameter approx. Number of cores 20.1 mm 20C+E 24.3 mm 30C+E 29.4 mm 50C+E BFAP05AA020CXWW BFAP05AA030CXWW BFAP05AA050CXWW OLX7/050-20ECBK OLX7/050-30EC OLX7/050-50ECBK Flex, Control 6 to 17 Core Sheath material: Voltage range: Flexible V OLX24/020-6EC Nominal cross section conductor Outer diameter approx. Number of cores 0.75 mm² 8.1 mm 6C+E 0.75 mm² 9.9 mm 11C+E 1 mm² 8.6 mm 6C+E 1 mm² 12.7 mm 17C+E 1.5 mm² 9.8 mm 6C+E 1.5 mm² 12.1 mm 11C+E 1 mm² 10.7 mm 11C+E CC7G0.75 CC12G0.75 CC7G1 CC18G1 CC7G1.5 CC12G1.5 CC12G1 OLX24/020-6EC OLX24/020-11EC OLX32/020-6EC OLX32/020-17EC OLX30/025-6EC OLX30/025-11EC OLX32/020-11EC 54

57 Cable and Wires Control Cable SWA, Control, 6 to 30 Core Sheath material: Sheath colour: Armouring: Conductor shape: Nominal voltage from to: Stranded Black Yes Circular kv OLX7/050-6SWA Nominal cross section Outer diameter approx. Number of strand and size Number of cores conductor 1.5 mm² 16.9 mm 7/0.50mm 6C+E 1.5 mm² 25.4 mm 7/0.50mm 20C+E 1.5 mm² 17 mm 7/0.50mm 10C+E 1.5 mm² 29.6 mm 7/0.50mm 30C+E 2.5 mm² 28.1 mm 7/0.67mm 20C+E BFCP05AA006CXAA BFCP05AA020CXAA BFCP05AA010CXAA BFCP05AA030CXAA BFCP07AA020CXAA OLX7/050-6SWA OLX7/050-20SWA OLX7/050-10SWA OLX7/050-30SWA OLX7/067-20SWA Data Cable Cable, Data, Cat 5E & 6 Nominal cross section conductor: 0.22 mm² Polyolefin Packaging type: Roll Number of pairs: 4 Cable type: UTP OLXJCAT5E Category Conductor category Sheath material Sheath colour Outer diameter approx. Number of strand and size Jelly filled CAT5E Solid Blue 5.3 mm 1/0.50mm CAT5E Underground PE Black 5.7 mm 1/0.50mm Yes CAT6 Underground PE Black 6.3 mm 1/0.54mm Yes JCAT5E JCAT5EFPA3 JCAT6FPA3 OLXJCAT5E OLXJCAT5EFPA3 OLXJCAT6FPA3 55

58 Cable and Wires Data Cable Cable, Data Nominal cross section conductor: Screen over stranding: Sheath material: Length: Number of strand and size: Standard for interfaces: Screened: 0.22 mm² Polypropylene Foil + braiding Polypropylene 100 m 7/0.20mm RS-422 Yes OLXJD1PSAA Number of pairs 1 2 JD1PSAA JD2PSAA OLXJD1PSAA OLXJD2PSAA Cable, Traffic Feeder Length: 1000 m Sheath colour: Black Outer diameter approx.: 9.3 mm Number of pairs: 1 OLXJTCD28A9002BKAA JTCD28A9002BKAA OLXJTCD28A9002BKAA 56

59 Cable and Wires Data Cable Cable: Detonator Nominal cross section conductor: Number of strand and size: Figure 8: 0.38 mm² 1/0.71mm 2C Yes OLXJDW1PRDWTA2 JDW1PRDWTA2 OLXJDW1PRDWTA2 Speaker Cable Cable, Speaker, Figure 8 Sheath material: Figure 8: 2C Yes Stranded OLXJSF5WTBK1 Nominal cross section Core identification Core colour Number of strand and size Length conductor 0.5 mm² Stripe Black-white 14/0.20mm 100 m 0.5 mm² Stripe Black-grey 14/0.20mm 100 m 0.75 mm² Stripe Black-white 24/0.20mm 100 m 0.75 mm² Stripe Black 14/0.20mm 100 m 0.75 mm² Stripe Black-grey 24/0.20mm 100 m 0.75 mm² Stripe Red-black 24/0.20mm 100 m 0.75 mm² Stripe Black-white 24/0.20mm 100 m 0.75 mm² White 24/0.20mm 100 m 0.75 mm² Stripe Blue-white 24/0.20mm 100 m 0.75 mm² Stripe Black-white 24/0.20mm 500 m 0.75 mm² Stripe Black-white 24/0.20mm 500 m 2 mm² Stripe Clear 64/0.20mm 100 m 2.6 mm² Stripe Clear 84/0.20mm 100 m JSF.5WTBK1 JSF.5GYBK1 JSF.75BKWT1 JSF.75BK1 JSF.75GYBK1 JSF.75RDBK1 JSF.75WTBK1 JSF.75WT1 JSF.75BEWT1 JSF.75BKWT5 JSF.75WTBK5 JSF2.0CL1 JSF2.6CL1 OLXJSF5WTBK1 OLXJSF5GYBK1 OLXJSF75BKWT1 OLXJSF75BK1 OLXJSF75GYBK1 OLXJSF75RDBK1 OLXJSF75WTBK1 OLXJSF75WT1 OLXJSF75BEWT1 OLXJSF75BKWT5 OLXJSF75WTBK5 OLXJSF20CL1 OLXJSF26CL1 57

60 Cable and Wires Signal & Telecommunications Cable Cable: Garden Sheath material: Sheath colour: Length: Cable application: Figure 8: Stranded Black 100 m Garden 2C Yes OLXJSF1.3GLBK1 Outer diameter approx. Nominal cross section conductor Number of strand and size 1.3 mm 1.3 mm² 26/0.25mm 2.5 mm 2.5 mm² 14/0.20mm 4 mm 4 mm² 84/0.20mm 6 mm 6 mm² 128/0.25mm 10 mm 10 mm² 348/0.20mm JSF1.3GLBK1 JSF2.5GLBK1 JSF4GLBK100 JSF6GLBK100 JSF10GLBK100 OLXJSF1.3GLBK1 OLXJSF2.5GLBK1 OLXJSF4GLBK100 OLXJSF6GLBK100 OLXJSF10GLBK100 Cable: Security Cable application: Security OLXJSC2WT4CB Sheath colour Outer diameter approx. Length Number of pairs Nominal cross section conductor Number of strand and size White 3.6 mm 300 m 0.22 mm² 7/0.20mm 4 White 3.6 mm 100 m 0.22 mm² 7/0.20mm 4 White 4.9 mm 100 m 0.22 mm² 7/0.20mm 6 Grey 4.7 mm 100 m 0.5 mm² 14/0.20mm 4 White 4.7 mm 100 m 0.5 mm² 14/0.20mm 4 White 4.7 mm 100 m 0.5 mm² 14/0.20mm 4 White 5.6 mm 100 m 0.5 mm² 14/0.20mm 6 White 5.6 mm 200 m 0.5 mm² 14/0.20mm 6 White 4.9 mm 300 m 0.22 mm² 7/0.20mm 6 White 4.3 mm 300 m mm² 7/0.25mm Grey 4.7 mm 300 m 0.5 mm² 14/0.20mm 4 Grey 5.6 mm 100 m 0.5 mm² 14/0.20mm 6 Number of conductors JSC.2WT4CB30 JSC.2WT4C1 JSC.2WT6C1 JSC.5GY4C1 JSC.5WT4CB30 JSC.5WT4C1 JSC.5WT6C1 JSC.5WT6CB20 JSC.2WT6CB30 JD2PISB30 JSC.5GY4CB30 JSC.5GY6C1 OLXJSC2WT4CB OLXJSC2WT4C1 OLXJSC2WT6C1 OLXJSC5GY4C1 OLXJSC5WT4CB OLXJSC5WT4C1 OLXJSC5WT6C1 OLXJSC5WT6CB20 OLXJSC2WT6CB30 OLXJD2PISB30 OLXJSC5GY4CB OLXJSC5GY6C1 58

61 Cable and Wires Signal & Telecommunications Cable Cable: Instrumentation Armouring: Sheath material: Sheath colour: Cable application: Screened: No Black Instrumentation Yes OLXIEC183-2 Outer diameter approx. Number of pairs Nominal cross section Number of strand and size conductor 7.8 mm mm² 7/0.30mm 5.2 mm mm² 7/0.30mm 8.4 mm mm² 7/0.30mm 10 mm mm² 7/0.30mm 7.8 mm mm² 7/0.30mm 10.2 mm mm² 7/0.50mm 6.6 mm mm² 7/0.50mm 6.6 mm mm² 7/0.50mm 6.6 mm mm² 7/0.50mm 6.6 mm mm² 7/0.50mm 6.6 mm mm² 7/0.50mm IEC183AA002CXAA IEB183AA001CXAA IEC183AA004CXAA IEC183AA006CXAA IEC183AA010CXAA IEF184AA001CXAA IEB184AA001CXAA IEC184AA002CXAA IEC184AA004CXAA IEC184AA010CXAA IEG184AA002CXAA OLXIEC183-2 OLXIEB183-1 OLXIEC183-4 OLXIEC183-6 OLXIEC OLXIEF184-1 OLXIEB184-1 OLXIEC184-2 OLXIEC184-4 OLXIEC OLXIEG

62 Cable and Wires Signal & Telecommunications Cable Cable: Instrumentation-Fire Rated Series or range: Pyrolex ceramifiable Stranded Sheath colour: Red Cable application: Instrumentation Halogen free: Yes Operating temperature: 90 C Low smoke: Yes OLX24/020-2PR Outer diameter approx. Number of pairs Nominal cross section Number of strand and size conductor 12.2 mm mm² 24/0.20mm 7.8 mm mm² 24/0.20mm 13.5 mm mm² 24/0.20mm 16.3 mm mm² 24/0.20mm 20.4 mm mm² 24/0.20mm 8.4 mm mm² 46/0.20mm 13.2 mm mm² 46/0.20mm 17.6 mm mm² 46/0.20mm 22.4 mm mm² 46/0.20mm PBKP03AA002JBAA PBKP03AA001JBAA PBKP03AA004JBAA PBKP03AA006JBAA PBKP03AA010JBAA PBK184AA001JBAA PBK184AA002JBAA PBK184AA006JBAA PBK184AA010JBAA OLX24/020-2PR OLX24/020-1PR OLX24/020-4PR OLX24/020-6PR OLX24/020-10PR OLX46/020-1PR OLX46/020-2PR OLX46/020-6PR OLX46/020-10PR Cable: Telephone Sheath material: Cable application: Jelly filled: PE Telephone No OLXJUMPRW250 Outer diameter approx. Length Number of pairs Number of cores Installation type 1.9 mm 250 m 2C 8.5 mm 200 m 10 Inside JUMPRW250 TINT010A2 OLXJUMPRW250 OLX1/040-10CTEL 60

63 Cable and Wires Coaxial Cable Cable: Coaxial Sheath colour: Characteristic impedance: Outer diameter approx.: Cable application: Cable design: Packaging type: Length: Black 75 Ohm 6.1 mm Cctv RG59B/U Roll 100 m 1C OLXJBCRG59BUCCTV1 JBCRG59BUCCTV1 OLXJBCRG59BUCCTV1 61

64 Cable Glands Cable Gland Glands - General Purpose, for Armoured Cable ALCAW16 Model: AW Material: Brass Surface treatment: Nickel plated Halogen free: No With locknut: Yes Operating temperature range: C Suitable for cable type: Armoured Standards compliance: AS Immersing depth: 30 m UV-protection: No Degree of protection IP: IP66/IP68 Material sealing: TPE Thread pitch: 1.5 mm Thread type: Metric Nominal thread size metric Thread length Width across flat Width across angle Seal A range Seal B range Seal A over braid max Exposed length SWA SWA diameter range Package size Suitable rubber shroud 16 mm 12 mm 27.5 mm 29.6 mm mm mm 10 mm 11.5 mm mm 20 ALCSG2S 20 mm 12 mm 24 mm 26 mm mm mm 10 mm 11.5 mm mm 14 ALCSG1S 20 mm 12 mm 32.5 mm 35 mm mm mm 14 mm 11.5 mm mm 20 ALCSG2L 20 mm 12 mm 25 mm 26.9 mm mm 11.5 mm 11.5 mm mm 20 ALCSG2S 20 mm 12 mm 32.5 mm 35 mm mm 16 mm 11.5 mm mm 20 ALCSG2L 25 mm 14 mm 37.5 mm 40.3 mm mm mm 19 mm 14 mm mm 15 ALCSG3S 32 mm 14 mm 47.5 mm 51 mm mm mm 26 mm 17 mm mm 5 ALCSG4S 40 mm 15 mm 57.5 mm 61.9 mm mm mm 33 mm 17 mm mm 5 ALCSG5S 50 mm 15 mm 70 mm 75.3 mm mm mm 42 mm 20 mm mm 2 ALCSG6S 50 mm 15 mm 70 mm 75.3 mm mm 44.5 mm 18 mm 2.5 mm 2 ALCSG6S 63 mm 19 mm 85 mm 91 mm mm mm 55 mm 20 mm mm 1 ALCSG7S 63 mm 19 mm 85 mm 91 mm mm 56.5 mm 19 mm mm 1 ALCSG7S 75 mm 19 mm 100 mm 108 mm mm mm 63 mm 26 mm mm 1 ALCSG8S 90 mm 19 mm 110 mm 119 mm mm mm 75 mm 31 mm mm 1 ALCSG9S 90 mm 19 mm 115 mm 124 mm mm 83 mm 30 mm mm 1 ALCAW16 ALCAW20SB ALCAW20 ALCAW20MR ALCAW20UR ALCAW25 ALCAW32 ALCAW40 ALCAW50 ALCAW50L ALCAW63 ALCAW63L ALCAW75 ALCAW90 ALCAW90B 62

65 Cable Glands Cable Gland Glands - General Purpose, for Unarmoured Cable ALCUW12 Model: UW Material: Brass Surface treatment: Nickel plated Halogen free: No With locknut: Yes Operating temperature range: C Suitable for cable type: Unarmoured Standards compliance: AS O-ring material: NBR UV-protection: No Degree of protection IP: IP66/IP68 Material sealing: TPE Thread pitch: 1.5 mm Thread type: Metric Nominal thread size metric Thread length Width across flat Width across angle Seal A range Seal B range Package size Suitable rubber shroud 12 mm 10 mm 17.5 mm 18.9 mm mm mm 30 ALCSG0S 16 mm 10 mm 20 mm 21.6 mm mm mm 30 ALCSG0S 20 mm 10 mm 25 mm 27.1 mm mm mm 20 ALCSG1S 20 mm 10 mm 24 mm 26 mm mm mm 20 ALCSG1S 25 mm 12 mm 32.5 mm 35.2 mm mm mm 15 ALCSG2L 32 mm 12 mm 37.5 mm 40.6 mm mm mm 10 ALCSG3S 40 mm 15 mm 47.5 mm 51.4 mm mm mm 8 ALCSG4S 50 mm 15 mm 57.5 mm 62.2 mm mm mm 5 ALCSG5S 63 mm 19 mm 70 mm 75.8 mm mm mm 2 ALCSG6S 16 mm 10 mm 20 mm 21.6 mm mm mm 30 ALCSG0S 75 mm 19 mm 90 mm 97.4 mm mm mm 2 ALCSG7S 105 mm 30 mm 120 mm 129 mm mm mm 1 ALCSG10S 120 mm 30 mm 140 mm 150 mm mm mm 1 ALCSG11S 120 mm 30 mm 140 mm 150 mm mm 1 ALCSG11S ALCUW12 ALCUW16S ALCUW20 ALCUW20A ALCUW25 ALCUW32 ALCUW40 ALCUW50 ALCUW63 ALCUW16 ALCUW75 ALCUW105 ALCUW120A ALCUW120B 63

66 Cable Glands Cable Gland Glands - Hazardous Area, for /SWA Cable ALCHAW20 Model: HAW Material: Brass Surface treatment: Nickel plated Halogen free: No With locknut: Yes Operating temperature range: C Suitable for cable type: Armoured Approval certificate number: ALCHAW20LR-ALCHAW90B AUS Ex Standards compliance: AS/NZS60079, AS/NZS , AS Hazard class I: I, IIC, IIB, IIC Explosive class: Exd, Exe Immersing depth: 30 m UV-protection: No Degree of protection IP: IP66/IP68 Material sealing: TPE Explosion safety category for dust: DIP A21 Thread pitch: 1.5 mm Thread type: Metric Nominal thread size metric Thread length Width across flat Width across angle Seal A range Seal B range Seal A outer over cable range Exposed length SWA SWA diameter range Package size Suitable rubber shroud 20 mm 20 mm 27.5 mm 29.8 mm mm mm mm 10.5 mm mm 20 ALCSG2S 20 mm 15 mm 25 mm 27.1 mm mm mm 7 mm mm 20 ALCSG1S 20 mm 16 mm 27.5 mm 29.8 mm mm mm 10.5 mm mm 20 ALCSG2S 25 mm 20 mm 30 mm 32.5 mm mm mm mm 10.5 mm mm 12 ALCSG2L 25 mm 20 mm 37.5 mm 40.6 mm mm mm mm 13 mm mm 10 ALCSG3S 32 mm 20 mm 42.5 mm 46 mm mm mm mm 16 mm mm 6 ALCSG3L 32 mm 20 mm 47.5 mm 51.4 mm mm mm mm 16 mm mm 6 ALCSG4S 40 mm 20 mm 50 mm 54.1 mm mm mm mm 16 mm mm 4 ALCSG5S 40 mm 20 mm 57.5 mm 62.6 mm mm mm mm 16 mm mm 4 ALCSG5S 50 mm 20 mm 62.5 mm 67.6 mm mm mm mm 19 mm mm 2 ALCSG6S 50 mm 20 mm 70 mm 75.8 mm mm mm mm 19 mm mm 2 ALCSG6S 63 mm 25 mm 75 mm 81.2 mm mm mm mm 19 mm mm 1 ALCSG6L 63 mm 25 mm 85 mm 92 mm mm mm mm 19 mm mm 1 ALCSG7S 75 mm 25 mm 100 mm mm mm mm mm 24 mm mm 1 ALCSG8S 75 mm 25 mm 100 mm mm mm mm mm 24 mm mm 1 ALCSG8S 90 mm 25 mm 110 mm 119 mm mm mm mm 29 mm mm 1 ALCSG9S 90 mm 25 mm 110 mm 119 mm mm mm mm 29 mm mm 1 ALCSG9S ALCHAW20 ALCHAW20LR ALCHAW20SB ALCHAW25A ALCHAW25B ALCHAW32A ALCHAW32B ALCHAW40A ALCHAW40B ALCHAW50A ALCHAW50B ALCHAW63A ALCHAW63B ALCHAW75A ALCHAW75B ALCHAW90A ALCHAW90B 64

67 Cable Glands Cable Gland Glands - Hazardous Area, for Unarmoured Cable ALCHUW20SB Model: HUW Material: Brass Surface treatment: Nickel plated Halogen free: No With locknut: Yes Operating temperature range: C Suitable for cable type: Unarmoured Approval certificate number: ALCHUW20SB-ALCHUW90 AUS Ex Standards compliance: AS/NZS60079, AS/NZS , AS Hazard class I: I, IIC, IIB, IIC Explosive class: Exd, Exe Immersing depth: 30 m UV-protection: No Degree of protection IP: IP66/IP68 Material sealing: TPE Explosion safety category for dust: DIP A21 Thread pitch: 1.5 mm Thread type: Metric Nominal thread size metric Thread length Width across flat Width across angle Seal A range Seal B range Seal C range Package size Suitable rubber shroud 20 mm 12 mm 25 mm 27.1 mm mm mm 20 ALCSG1S 20 mm 12 mm 30 mm 32.5 mm mm mm 20 ALCSG2L 20 mm 12 mm 30 mm 32.5 mm mm mm 20 ALCSG2L 25 mm 12 mm 35 mm 37.9 mm mm mm 15 ALCSG3S 32 mm 15 mm 40 mm 43.3 mm mm mm 10 ALCSG3L 40 mm 15 mm 50 mm 54.1 mm mm mm 8 ALCSG4S 50 mm 20 mm 62.5 mm 67.7 mm mm mm mm 2 ALCSG5S 63 mm 25 mm 75 mm 81.2 mm mm mm mm 2 ALCSG6L 75 mm 25 mm 90 mm 97.4 mm mm mm mm 1 ALCSG7S 90 mm 30 mm 110 mm 119 mm mm mm 1 ALCSG9S ALCHUW20SB ALCHUW20A ALCHUW20B ALCHUW25 ALCHUW32 ALCHUW40 ALCHUW50 ALCHUW63 ALCHUW75 ALCHUW90 65

68 Cable Glands Cable Gland Glands - Hazardous Area, for Unarmoured Cable ALCHUW20SB-LTA16 Series or range: Alco Model: HUW Material: Brass Surface treatment: Nickel plated Halogen free: No Multi seal area: Yes Separable screw gland: Yes Operating temperature range: C Suitable for cable type: Unarmoured Approval certificate number: ALCHUW20SB-ALCHUW90 AUS Ex Standards compliance: AS/NZS60079, AS/NZS , AS Explosive class: Exd, Exe Immersing depth: 30 m UV-protection: No Degree of protection IP: IP66/IP68 Material sealing: TPE Explosion safety category for dust: DIP A21 Thread type: Metric Package size: 1 Nominal thread size metric Thread length Width across flat Width across angle Seal A range Seal B range Seal C range Suitable rubber shroud 20 mm 12 mm 26 mm 29 mm mm mm ALCSG2S 20 mm 12 mm 29 mm 32.7 mm mm mm ALCSG2S 20 mm 12 mm 35 mm 38.6 mm mm mm ALCSG2L 25 mm 12 mm 45 mm 50 mm mm mm ALCSG4S 32 mm 15 mm 54 mm 60 mm mm mm ALCSG5S 40 mm 15 mm 63 mm 69.2 mm mm mm ALCSG6S 50 mm 20 mm 72 mm 85 mm mm mm mm ALCSG6L ALCHUW20SB-LTA16 ALCHUW20A-LTA20 ALCHUW20B-LTA25 ALCHUW25-LTA32 ALCHUW32-LTA40 ALCHUW40-LTA50 ALCHUW50-LTA63 66

69 Cable Glands Cable Gland Glands + Hose Adapter - Hazardous Area, for Unarmoured Cable ALCHUW20B-H Model: HUW barbed nut Material: Brass Surface treatment: Nickel plated Halogen free: No With locknut: Yes Operating temperature range: C Suitable for cable type: Unarmoured Approval certificate number: ALCHUW20SB-ALCHUW90 AUS Ex Standards compliance: AS/NZS60079, AS/NZS , AS Hazard class I: I, IIC, IIB, IIC Explosive class: Exd, Exe Immersing depth: 30 m UV-protection: No Degree of protection IP: IP66/IP68 Material sealing: TPE Explosion safety category for dust: DIP A21 Thread pitch: 1.5 mm Thread type: Metric Package size: 1 Nominal thread size metric Thread length Width across flat Width across angle Seal A range Seal B range Seal C range Suitable rubber shroud 20 mm 12 mm 30 mm 32.5 mm mm mm ALCSG2L 20 mm 12 mm 25 mm 27.1 mm mm mm ALCSG1S 25 mm 12 mm 35 mm 37.9 mm mm mm ALCSG3S 32 mm 15 mm 40 mm 43.3 mm mm mm ALCSG3L 40 mm 15 mm 50 mm 54.1 mm mm mm ALCSG4S 50 mm 20 mm 62.5 mm 67.7 mm mm mm mm ALCSG5S ALCHUW20B-H ALCHUW20SB-H ALCHUW25-H ALCHUW32-H ALCHUW40-H ALCHUW50-H 67

70 Cable Glands Cable Gland Glands - Metal, for Emc Shielded Cables ELMEMC12 Model: EMC Material: Brass Surface treatment: Nickel plated Halogen free: No With locknut: Yes Operating temperature range: C Suitable for cable type: Screened O-ring material: NBR Material clamp: Polyamide 6 UV-protection: No Degree of protection IP: IP68 Material sealing: Neoprene Thread pitch: 1.5 mm Thread type: Metric Nominal thread size metric Thread length Width across flat Min shielded diameter Outside diameter cable range Package size Suitable rubber shroud 12 mm 12 mm 14 mm 2 mm mm 10 xx 16 mm 12 mm 20 mm 3.5 mm mm 10 ALCSG0S 20 mm 12 mm 24 mm 5.5 mm mm mm 6 mm 24 mm 4.5 mm mm 10 ALCSG0S 20 mm 12 mm 24 mm 5.5 mm mm 10 ALCSG1S 25 mm 12 mm 30 mm 7 mm mm 10 ALCSG2S 32 mm 15 mm 40 mm 12 mm mm 5 ALCSG2L 40 mm 15 mm 50 mm 18 mm mm 5 ALCSG4S 50 mm 15 mm 58 mm 26 mm mm 1 ALCSG5S 63 mm 15 mm 64 mm 30 mm mm 1 ALCSG6S 63 mm 10 mm 75 mm 33 mm mm 1 ALCSG6S ELMEMC12 ELMEMC16 ELMEMC20G3 ELMEMC20S ELMEMC20 ELMEMC25 ELMEMC32 ELMEMC40 ELMEMC50 ELMEMC63 ELMEMC63L 68

71 Cable Glands Cable Gland Glands - Metal, for Screened Cables ALCEMC16 Model: ALCEMC Material: Brass Surface treatment: Nickel plated Halogen free: No With locknut: Yes Operating temperature range: C Suitable for cable type: Screened Standards compliance: AS Immersing depth: 30 m UV-protection: No Degree of protection IP: IP66/IP68 Material sealing: TPR Thread pitch: 1.5 mm Thread type: Metric Nominal thread size metric Thread length Width across flat Width across angle Seal A range Seal B range Outer sheath strip length Braid strip length Overscreen os range Package size Suitable rubber shroud 16 mm 12 mm 27.5 mm 29.8 mm mm 40 mm 14 mm mm 20 ALCSG2S 20 mm 12 mm 32.5 mm 35.2 mm mm 40 mm 14 mm mm 20 ALCSG2L 25 mm 12 mm 37.5 mm 40.6 mm mm 40 mm 14 mm mm 15 ALCSG3S 32 mm 12 mm 37.5 mm 40.6 mm mm 40 mm 14 mm mm 5 ALCSG3S 40 mm 15 mm 47.5 mm 51.4 mm mm mm 49 mm 16 mm mm 5 ALCSG4S 12 mm 12 mm 17.5 mm 18.9 mm mm mm 35 mm 12 mm mm 20 ALCSG0S 50 mm 15 mm 57.5 mm 62.6 mm mm mm 55 mm 20 mm mm 3 ALCSG5S 63 mm 19 mm 70 mm 75.8 mm mm mm 69 mm 26 mm mm 2 ALCSG6S 75 mm 19 mm 85 mm 92 mm mm 69 mm 26 mm mm 1 ALCSG7S 75 mm 19 mm 85 mm 92 mm mm 75 mm 29 mm mm 1 ALCSG7S 75 mm 19 mm 85 mm 92 mm mm 75 mm 29 mm mm 1 ALCSG7S ALCEMC16 ALCEMC20 ALCEMC25 ALCEMC32 ALCEMC40 ALCEMC12 ALCEMC50 ALCEMC63 ALCEMC75A ALCEMC75B ALCEMC75C 69

72 Cable Glands Cable Gland Glands - Barrier for Armoured Cables ALCHAW20-B Model: HAW barrier Material: Brass Surface treatment: Nickel plated Halogen free: No With locknut: Yes Operating temperature range: C Suitable for cable type: Armoured Approval certificate number: ALCHAW20LRB-ALCHAW90B-B AUS Ex Standards compliance: AS/NZS60079, AS/NZS , AS Hazard class I: I, IIC, IIB, IIC Explosive class: Exd, Exe Immersing depth: 30 m UV-protection: No Degree of protection IP: IP66/IP68 Material sealing: TPE epoxy resin Explosion safety category for dust: DIP A21 Thread pitch: 1.5 mm Thread type: Metric Nominal thread size metric Thread length Width across flat Width across angle Seal A outer over cable range Exposed length bedding Exposed length SWA SWA diameter range Under bedding dia max Package size Suitable rubber shroud Suitable resin pack 20 mm 20 mm 27.5 mm 29.8 mm mm 11 mm 10.5 mm mm 8 mm 20 ALCSG2S ALCIP38 x1 20 mm 15 mm 25 mm 27.1 mm mm 8 mm 7 mm mm 20 ALCSG1S ALCIP38 x1 25 mm 20 mm 30 mm 32.5 mm mm 11 mm 10.5 mm mm 12 mm 12 ALCSG2L ALCIP38 x1 20 mm 16 mm 27.5 mm 29.8 mm mm 11 mm 10.5 mm mm 10.1 mm 20 ALCSG2S ALCIP38 x1 25 mm 20 mm 37.5 mm 40.6 mm mm 14 mm 10.5 mm mm 16 mm 10 ALCSG3S ALCIP38 x1 32 mm 20 mm 42.5 mm 46 mm mm 16 mm 16 mm mm 19.5 mm 6 ALCSG3L ALCIP38 x1 32 mm 20 mm 47.5 mm 51.4 mm mm 16 mm 16 mm mm 23 mm 6 ALCSG4S ALCIP38 x1 40 mm 20 mm 50 mm 54.1 mm mm 16 mm 16 mm mm 27 mm 4 ALCSG5S ALCIP125 x1 40 mm 20 mm 57.5 mm 62.6 mm mm 16 mm 16 mm mm 31 mm 4 ALCSG5S ALCIP125 x1 50 mm 20 mm 62.5 mm 67.6 mm mm 16 mm 19 mm mm 35 mm 2 ALCSG6S ALCIP125 x1 50 mm 20 mm 70 mm 75.8 mm mm 16 mm 19 mm mm 39 mm 2 ALCSG6S ALCIP125 x1 63 mm 25 mm 75 mm 81.2 mm mm 20 mm 19 mm mm 44.5 mm 1 ALCSG6L ALCIP180 x1 63 mm 25 mm 85 mm 92 mm mm 20 mm 19 mm mm 50 mm 1 ALCSG7S ALCIP180 x1 75 mm 25 mm 100 mm mm mm 20 mm 24 mm mm 55.5 mm 1 ALCSG8S ALCIP125 x2 75 mm 25 mm 100 mm mm mm 20 mm 24 mm mm 61 mm 1 ALCSG8S ALCIP125 x2 90 mm 25 mm 110 mm 119 mm mm 20 mm 29 mm mm 66 mm 1 ALCSG9S ALCIP180 x2 90 mm 25 mm 110 mm 119 mm mm 20 mm 29 mm mm 71.5 mm 1 ALCSG9S ALCIP180 x2 ALCHAW20-B ALCHAW20LRB ALCHAW25A-B ALCHAW20SB-B ALCHAW25B-B ALCHAW32A-B ALCHAW32B-B ALCHAW40A-B ALCHAW40B-B ALCHAW50A-B ALCHAW50B-B ALCHAW63A-B ALCHAW63B-B ALCHAW75A-B ALCHAW75B-B ALCHAW90A-B ALCHAW90B-B 70

73 Cable Glands Cable Gland Glands - Metal, Shutter Type for Unarmoured cable ALCBRGM6 Model: BRGM Material: Brass Surface treatment: Nickel plated Halogen free: No With locknut: Yes Operating temperature range: C Suitable for cable type: Unarmoured O-ring material: NBR Material clamp: Polyamide 6 UV-protection: No Degree of protection IP: IP68 Material sealing: Neoprene Thread type: Metric Nominal thread size metric Thread length Width across flat Outside diameter cable range Thread pitch Package size Suitable rubber shroud 6 mm 5 mm 10 mm mm 1 mm 10 8 mm 5 mm 11 mm mm 1.25 mm mm 6 mm 13 mm mm 1.5 mm mm 12 mm 14 mm mm 1.5 mm mm 12 mm 18 mm mm 1.5 mm 15 ALCSG0S 20 mm 12 mm 22 mm mm 1.5 mm 10 ALCSG1S 25 mm 12 mm 27 mm mm 1.5 mm 10 ALCSG2S 32 mm 15 mm 34 mm mm 1.5 mm 5 ALCSG2L 40 mm 15 mm 43 mm mm 1.5 mm 4 ALCSG3L 50 mm 15 mm 55 mm mm 1.5 mm 2 ALCSG5S 63 mm 18 mm 68 mm mm 1.5 mm 1 ALCSG6S ALCBRGM6 ALCBRGM8 ALCBRGM10 ALCBRGM12 ALCBRGM16 ALCBRGM20 ALCBRGM25 ALCBRGM32 ALCBRGM40 ALCBRGM50 ALCBRGM63 71

74 Cable Glands Cable Gland Glands - S/S, Shutter Type ALCBRGM16-SS Model: BRGM Material: Stainless steel Halogen free: No With locknut: Yes Operating temperature range: C Suitable for cable type: Unarmoured O-ring material: NBR Material clamp: Polyamide 6 UV-protection: No Degree of protection IP: IP68 Material sealing: Neoprene Thread pitch: 1.5 mm Thread type: Metric Nominal thread size metric Thread length Width across flat Outside diameter cable range Package size Suitable rubber shroud 16 mm 12 mm 19 mm mm 15 ALCSG0S 20 mm 12 mm 22 mm mm 10 ALCSG1S 25 mm 12 mm 27 mm mm 10 ALCSG2S 32 mm 15 mm 36 mm mm 5 ALCSG3S 40 mm 15 mm 46 mm mm 4 ALCSG3L 50 mm 15 mm 55 mm mm 2 ALCSG5S 63 mm 18 mm 70 mm mm 1 ALCSG6S ALCBRGM16-SS ALCBRGM20-SS ALCBRGM25-SS ALCBRGM32-SS ALCBRGM40-SS ALCBRGM50-SS ALCBRGM63-SS 72

75 Cable Glands Cable Gland Glands - Nylon: Alco, for Cable ALCMG12 Model: MG Material: Polyamide Halogen free: Yes Colour: Black With locknut: Yes Operating temperature range: C Suitable for cable type: UV-protection: Yes Degree of protection IP: IP66/IP68 Material sealing: Neoprene Thread type: Metric Nominal thread size metric Thread length Width across flat Outside diameter cable range Thread pitch Package size Suitable rubber shroud 12 mm 8 mm 15 mm mm 1.25 mm mm 15 mm 22 mm mm 1.5 mm 25 ALCSG1S 20 mm 15 mm 27 mm mm 1.5 mm 25 ALCSG2S 25 mm 15 mm 29 mm mm 1.5 mm 15 ALCSG2L 32 mm 15 mm 42 mm mm 1.5 mm 5 ALCSG3L 40 mm 18 mm 53 mm mm 1.5 mm 4 ALCSG5S 50 mm 18 mm 60 mm mm 1.5 mm 2 ALCSG5S 63 mm 18 mm 65 mm mm 1.5 mm 2 ALCSG6S ALCMG12 ALCMG16 ALCMG20 ALCMG25 ALCMG32 ALCMG40 ALCMG50 ALCMG63 73

76 Cable Glands Cable Gland Glands - Nylon: Tradeforce, for Cable TRFMG12 Series or range: Tradeforce Model: MG Material: Polyamide Halogen free: Yes Colour: Black Bend radius protection/trumpet flare: No With locknut: Yes Multi seal area: No Type of sealing: Sealing ring Operating temperature range: C Suitable for cable type: Shock resistant: No UV-protection: Yes Degree of protection IP: IP66/IP68 Material sealing: Neoprene Thread type: Metric Nominal thread size metric Thread length Outside diameter cable range Thread pitch Package size Suitable rubber shroud 12 mm 8 mm mm 1.25 mm mm 15 mm mm 1.5 mm 25 ALCSG1S 20 mm 15 mm mm 1.5 mm 25 ALCSG2S 25 mm 15 mm mm 1.5 mm 15 ALCSG2L 32 mm 15 mm mm 1.5 mm 5 ALCSG3L 40 mm 18 mm mm 1.5 mm 4 ALCSG5S 50 mm 18 mm mm 1.5 mm 2 ALCSG5S TRFMG12 TRFMG16 TRFMG20 TRFMG25 TRFMG32 TRFMG40 TRFMG50 74

77 Cable Glands Sealing Disc for Cable Gland Washer - Fibre ALCFW12 Material: Fibre Colour: Red Type of sealing: Washer Package size: 10 Suitable for nominal thread metric/pg Inner diameter 12 mm 12 mm 16 mm 16 mm 20 mm 20 mm 25 mm 25 mm 32 mm 32 mm 40 mm 40 mm 50 mm 50 mm 63 mm 63 mm 75 mm 75 mm ALCFW12 ALCFW16 ALCFW20 ALCFW25 ALCFW32 ALCFW40 ALCFW50 ALCFW63 ALCFW75 75

78 Cable Glands Cable Gland Shroud Glands - Shroud, ALCSG1 Shore A hardness: 73 Elongation at break: 370 % Tensile strength: 12 mpa UV resistant: No Relative density: 1.3 g/cm³ Operating temperature range: C Cable diameter Total length Inner diameter Outer diameter Colour Package size 7 mm 70 mm 25 mm 27 mm Orange 50 7 mm 70 mm 25 mm 27 mm Black mm 70 mm 29 mm 33 mm Orange mm 70 mm 29 mm 33 mm Black mm 85 mm 39.8 mm 41 mm Orange mm 85 mm 39.8 mm 41 mm Black mm 85 mm 48 mm 50 mm Orange mm 85 mm 48 mm 50 mm Black mm 97 mm 56 mm 58 mm Orange 5 30 mm 97 mm 56 mm 58 mm Black mm 110 mm 71 mm 73 mm Orange mm 110 mm 71 mm 73 mm Black mm 125 mm 73 mm 75 mm Orange mm 125 mm 73 mm 75 mm Black 5 ALCSG1 ALCSG1B ALCSG2 ALCSG2B ALCSG3 ALCSG3B ALCSG4 ALCSG4B ALCSG5 ALCSG5B ALCSG6 ALCSG6B ALCSG7 ALCSG7B 76

79 Cable Glands Cable Gland Shroud Glands - Shroud, Rubber ALCSG0S Material: Silicone rubber Tensile strength: 10 mpa Tear strength: 13.5 mpa UV resistant: Yes Low smoke: Yes Operating temperature range: C Cable diameter Total length Inner diameter Outer diameter Sleeve length Colour Package size 2 mm 44 mm 20 mm 22 mm 20 mm Orange mm 69 mm 25 mm 27 mm 43 mm Orange mm 87 mm 35 mm 38 mm 55 mm Orange mm 100 mm 44 mm 47 mm 65 mm Orange mm 127 mm 81 mm 85 mm 80 mm Orange 5 62 mm 140 mm 104 mm 109 mm 90 mm Orange 1 62 mm 170 mm 114 mm 120 mm 110 mm Orange 1 78 mm 135 mm 124 mm 130 mm 88 mm Orange 1 87 mm 137 mm 144 mm 150 mm 88 mm Orange 1 6 mm 69 mm 25 mm 27 mm 43 mm Black mm 87 mm 35 mm 38 mm 55 mm Black mm 76 mm 29 mm 31 mm 50 mm Orange mm 76 mm 29 mm 31 mm 50 mm Black mm 96 mm 40 mm 42 mm 60 mm Orange mm 96 mm 40 mm 42 mm 60 mm Black mm 108 mm 51 mm 53 mm 65 mm Orange mm 115 mm 62 mm 65 mm 70 mm Orange 5 38 mm 126 mm 75 mm 78 mm 75 mm Orange 5 48 mm 135 mm 91 mm 95 mm 85 mm Orange 4 20 mm 108 mm 51 mm 53 mm 65 mm Black mm 115 mm 62 mm 65 mm 70 mm Black 1 42 mm 127 mm 81 mm 85 mm 80 mm Black 5 38 mm 126 mm 75 mm 78 mm 75 mm Black 5 48 mm 135 mm 91 mm 95 mm 85 mm Black 4 62 mm 140 mm 104 mm 109 mm 90 mm Black 1 62 mm 170 mm 114 mm 120 mm 110 mm Black 1 ALCSG0S ALCSG1S ALCSG2L ALCSG3L ALCSG6L ALCSG8S ALCSG9S ALCSG10S ALCSG11S ALCSG1BS ALCSG2LB ALCSG2S ALCSG2SB ALCSG3S ALCSG3SB ALCSG4S ALCSG5S ALCSG6S ALCSG7S ALCSG4SB ALCSG5SB ALCSG6LB ALCSG6SB ALCSG7SB ALCSG8SB ALCSG9SB 77

80 Cable Glands Cable Joint Branch Kit Resin Joints - Type Y ALC133Y00 Model: Cast resin Voltage range: kv Type Cable diameter branch cable Cable diameter main cable Length Height Inner height Width Y00 23 mm 23 mm 150 mm 75 mm 38 mm 50 mm Y0 17 mm 17 mm 185 mm 80 mm 45 mm 55 mm Y1 22 mm 22 mm 240 mm 110 mm 60 mm 70 mm Y2 33 mm 37 mm 285 mm 120 mm 65 mm 75 mm Y3 37 mm 42 mm 240 mm 145 mm 100 mm 110 mm Y mm 54 mm 300 mm 150 mm 110 mm 120 mm Y4 37 mm 53 mm 285 mm 170 mm 110 mm 120 mm Y mm 56 mm 335 mm 193 mm 120 mm 130 mm Y5 52 mm 62 mm 382 mm 220 mm 140 mm 150 mm Y6 80 mm 90 mm 570 mm 275 mm 180 mm 190 mm ALC133Y00 ALC133Y0 ALC133Y1 ALC133Y2 ALC133Y3 ALC133Y3.5 ALC133Y4 ALC133Y4.5 ALC133Y5 ALC133Y6 78

81 Cable Glands Cable Resin Cast Resin - Type EG (Non-Removable) ALC124EG80 Material: 2-component polyurethane resin Storage time in months: 40 Type EG80 EG143 EG286 EG370 EG464 EG730 EG1000 EG1150 EG1500 EG2000 Volume 80 ml 143 ml 286 ml 370 ml 464 ml 730 ml 1000 ml 1150 ml 1500 ml 2000 ml ALC124EG80 ALC124EG143 ALC124EG286 ALC124EG370 ALC124EG464 ALC124EG730 ALC124EG1000 ALC124EG1150 ALC124EG1500 ALC124EG

82 Cable Glands Cable Resin Cast Resin - Type KG (Removable) ALC125KG143 Material: 2-component polyurethane resin Storage time in months: 24 Working time: 60 min Working time temperature: 20 C Tensile strength: 7 N/cm² Shore A hardness: 10 Relative density: 1 g/cm³ Type KG143 KG286 KG730 Volume 143 ml 286 ml 730 ml ALC125KG143 ALC125KG286 ALC125KG730 80

83 Cable Glands Cable Resin Putty - Insul/Epoxy resin ALCIP38 Material: Epoxy resin Mining sector approval: Yes Setting time from/to: min Working time: min Working time temperature: 23 C Length 38 mm 125 mm 180 mm ALCIP38 ALCIP125 ALCIP180 81

84 Cable Glands Straight-through Heatshrink and Cast Joints Cast Resin Joints - Type M ALC124M11 Voltage range: kv Model: Cast resin Type Max cross section per cndtr 4C plastic insulated Max cross section per cndtr 4C armoured Tube length Inner height Height Cable diameter range M11 10 mm² 190 mm 36 mm 50 mm mm M12 25 mm² 260 mm 47 mm 63 mm mm M13 50 mm² 35 mm² 360 mm 55 mm 75 mm mm M14 95 mm² 70 mm² 400 mm 70 mm 95 mm mm M mm² 120 mm² 530 mm 100 mm 120 mm mm M mm² 240 mm² 700 mm 125 mm 160 mm mm ALC124M11 ALC124M12 ALC124M13 ALC124M14 ALC124M15 ALC124M16 82

85 Cable Glands Straight-through Heatshrink and Cast Joints Cast Resin Joints - Type MZ ALC124MZ0 Voltage range: kv Model: Cast resin Type Number of conductors for 1.5 dia wire Number of conductors for 2.5 dia wire Tube length Inner height Height MZ mm 35 mm 55 mm MZ mm 23 mm 35 mm ALC124MZ0 ALC124MZ00 83

86 Cable Glands Earthing Lug for Cable Gland Earth Tags - Metal ALCET16 Surface treatment: Material: Nickel plated Brass Suitable for nominal thread metric/pg Material thickness Width largest end Radius small hole Radius large hole Centre to centre Total length Width small Package size mm 1.8 mm mm 10 mm mm 30 mm 55 mm 7 mm mm 1.8 mm mm 10 mm mm 30 mm 55 mm 7 mm mm 1.8 mm mm 12 mm mm 41.3 mm 69 mm 10.5 mm mm 1.8 mm 43.3 mm 12 mm mm 51 mm 85 mm 12 mm mm 1.8 mm mm 20 mm mm 54 mm 100 mm 13.5 mm mm 2 mm 66.4 mm 20 mm 33.2 mm 62 mm 120 mm 13.5 mm mm 2 mm mm 20 mm mm 84 mm 141 mm 13.5 mm mm 2 mm mm 20 mm mm 100 mm 172 mm 13.5 mm 1 ALCET16 ALCET20 ALCET25 ALCET32 ALCET40 ALCET50 ALCET63 ALCET75 84

87 Cable Glands Locknuts and Lockrings Locknuts - Metal ALCPLN12 Material: Shape: Surface treatment: Brass Hexagonal Nickel plated Nominal thread size metric Thread pitch Depth Width across angle Width across flat Package size 12 mm 1.25 mm 4 mm 22 mm 14.4 mm mm 1.5 mm 4 mm 24 mm 19.2 mm mm 1.5 mm 4 mm 30 mm 24 mm mm 1.5 mm 5 mm 37 mm 30 mm mm 1.5 mm 5 mm 45 mm 38.4 mm mm 1.5 mm 8 mm 55 mm 48 mm mm 1.5 mm 8 mm 65 mm 60 mm mm 1.5 mm 8 mm 83 mm 75.6 mm 5 75 mm 1.5 mm 9.5 mm 110 mm 90 mm 1 90 mm 1.5 mm 9.5 mm 124 mm 108 mm mm 1.5 mm 9.5 mm 144 mm 126 mm mm 1.5 mm 9.5 mm 165 mm 144 mm 1 ALCPLN12 ALCPLN16 ALCPLN20 ALCPLN25 ALCPLN32 ALCPLN40 ALCPLN50 ALCPLN63 ALCPLN75 ALCPLN90 ALCPLN105 ALCPLN120 85

88 Cable Glands Locknuts and Lockrings Locknuts - Metal, For EMC Glands ALCEMC20-LN Material: Thread pitch: Shape: Surface treatment: Brass 1.5 mm Hexagonal Nickel plated Nominal thread size metric Depth Width across angle Width across flat Package size 20 mm 4 mm 30 mm 24 mm mm 5 mm 37 mm 30 mm mm 8 mm 83 mm 75.6 mm 5 ALCEMC20-LN ALCEMC25-LN ALCEMC63-LN 86

89 Cable Glands Pressure Spring Pressure Springs ALC126PS0 Material: Colour: Corrosion resistant: Special stainless steel Yes Suitable for cable diameter from/to Width Type mm 16 mm RF mm 16 mm RF mm 16 mm RF mm 16 mm RF mm 16 mm RF mm 20 mm RF mm 20 mm RF mm 16 mm RF0.5 ALC126PS0 ALC126PS1 ALC126PS2 ALC126PS3 ALC126PS4 ALC126PS5 ALC126PS6 ALC126PS0.5 87

90 Index - By Page ALCET16 84 ALCET20 84 ALCET25 84 ALCET32 84 ALCET40 84 ALCET50 84 ALCET63 84 ALCET75 84 ALCFW12 75 ALCFW16 75 ALCFW20 75 ALCFW25 75 ALCFW32 75 ALCFW40 75 ALCFW50 75 ALCFW63 75 ALCMG12 73 ALCMG16 73 ALCMG20 73 ALCMG25 73 ALCMG32 73 ALCMG40 73 ALCMG50 73 ALCMG63 73 ALCPLN12 85 ALCPLN16 85 ALCPLN20 85 ALCPLN25 85 ALCPLN32 85 ALCPLN40 85 ALCPLN50 85 ALCPLN63 85 ALCSG1 76 ALCSG1B 76 ALCSG2 76 ALCSG2B 76 ALCSG3 76 ALCSG3B 76 ALCSG4 76 ALCSG4B 76 ALCSG5 76 ALCSG5B 76 ALCSG6 76 ALCSG6B 76 ALCSG7 76 ALCSG7B 76 OLXIEB OLXIEB OLXIEC OLXIEC OLXIEC OLXIEC OLXIEC OLXIEC OLXIEC OLXIEF OLXJBCRG59BUCCTV1 61 OLXJCAT5E 55 OLXJD1PSAA 56 OLXJD2PSAA 56 OLXJSC2WT4CB 58 OLXJSC2WT4C1 58 OLXJSC2WT6C1 58 OLXJSC5GY4CB 58 OLXJSC5GY4C1 58 Page OLXJSC5GY6C1 58 OLXJSC5WT4CB 58 OLXJSC5WT4C1 58 OLXJSC5WT6C1 58 OLXJSF26CL1 57 OLXJSF5GYBK1 57 OLXJSF5WTBK1 57 OLXJSF75BEWT1 57 OLXJSF75BKWT1 57 OLXJSF75BKWT5 57 OLXJSF75BK1 57 OLXJSF75GYBK1 57 OLXJSF75RDBK1 57 OLXJSF75WTBK1 57 OLXJSF75WTBK5 57 OLXJSF75WT1 57 OLXJUMPRW OLX1/040-10CTEL 60 OLX1/113-1BK 22 OLX1/113-1R 22 OLX1/113-2ERB 29 OLX1/113-2ERBA2 29 OLX1/113-2RB 28 OLX1/113-2RW 28 OLX1/113BWBK 14 OLX1/113BWR 14 OLX1/113BWW 14 OLX127/252XLPE 27 OLX19/135-2EC 39 OLX19/135-2ECA5 39 OLX19/135-3EC 41 OLX19/135-3ECVA 49 OLX19/135-3SWA 47 OLX19/135-4EC 44 OLX19/135-4ECA5 44 OLX19/135-4SWA 47 OLX19/135BWBK 17 OLX19/135BWBKA5 17 OLX19/135BWEWA5 17 OLX19/135BWEW 17 OLX19/135BWR 17 OLX19/135BWRA5 17 OLX19/135XLPE 26 OLX19/135XLPEA5 26 OLX19/153-2EC 39 OLX19/153-3EC 41 OLX19/153-3ECVA 49 OLX19/153-3SWA 47 OLX19/153-4EC 44 OLX19/153-4ECA5 44 OLX19/153BWBKA5 18 OLX19/153BWEW 18 OLX19/153BWEWA1 18 OLX19/153BWR 18 OLX19/153BWRA5 18 OLX19/153XLPE 27 OLX19/178-3EC 41 OLX19/178-3ECVA 49 OLX19/178-3SWA 47 OLX19/178-4EC 44 OLX19/178-4SWA 47 OLX19/178BWEW 18 OLX19/178XLPE 27 OLX19/214-3EC 41 OLX19/214-3ECVA 49 Page OLX19/214-3SWA 47 OLX19/214-4EC 44 OLX19/214-4SWA 47 OLX19/214BWEW 18 OLX19/214XLPE 27 OLX24/020-1BL 19 OLX24/020-1BR 19 OLX24/020-1GY 19 OLX24/020-1O 19 OLX24/020-1W 19 OLX30/025-1BK 19 OLX30/025-1EW 19 OLX30/025-1GY 19 OLX30/025-1O 19 OLX30/025-1R 19 OLX30/025-1W 19 OLX30/025-3GY 45 OLX30/025H3O 45 OLX32/020-1BK 19 OLX32/020-1BR 19 OLX32/020-1O 19 OLX32/020-1R 19 OLX32/020-3GY 45 OLX37/178-3ECVA 49 OLX37/178-3SWA 47 OLX37/178-4EC 44 OLX37/178-4SWA 47 OLX37/178BWEW 18 OLX37/178XLPE 27 OLX37/203-3ECVA 49 OLX37/203-3SWA 47 OLX37/203-4EC 44 OLX37/203BWBK 18 OLX37/203BWEW 18 OLX37/203XLPE 27 OLX37/225-3SWA 47 OLX37/225XLPE 27 OLX37/252-3SWA 47 OLX37/252XLPE 27 OLX50/025-3GY 45 OLX61/225XLPE 27 OLX61/252AXLPE 27 OLX61/252XLPE 27 OLX61/285XLPE 27 OLX61/320XLPE 27 OLX7/050-1BK 22 OLX7/050-1R 22 OLX7/050-1W 22 OLX7/050-10EC 53 OLX7/050-10SWA 55 OLX7/050-12EC 53 OLX7/050-2AR 37 OLX7/050-2ARA2 37 OLX7/050-2ARA5 37 OLX7/050-2ECA1 38 OLX7/050-2ECA5 38 OLX7/050-2ERB 30 OLX7/050-2ERBA5 30 OLX7/050-2RB 29 OLX7/050-2RW 29 OLX7/050-2RWA5 29 OLX7/050-20ECBK 54 OLX7/050-20SWA 55 OLX7/ OLX7/050-3E 31 88

91 Index - By Page OLX7/050-3ECA1 40 OLX7/050-3ECA5 40 OLX7/050-30EC 54 OLX7/050-30SWA 55 OLX7/050-4EC 42 OLX7/050-4ECA1 42 OLX7/050-4ECA5 42 OLX7/050-6EC 53 OLX7/050-6ECA5 53 OLX7/050-6SWA 55 OLX7/050BWBK 14 OLX7/050BWBL 14 OLX7/050BWGY 14 OLX7/050BWR 14 OLX7/050BWW 14 OLX7/050EW 14 OLX7/067-1BK 23 OLX7/067-1R 23 OLX7/067-1RA5 23 OLX7/067-1W 23 OLX7/067-10EC 53 OLX7/067-2ECA1 38 OLX7/067-2ECA5 38 OLX7/067-2ERB 32 OLX7/067-2ERBA5 32 OLX7/067-2ERBB 32 OLX7/067-2RB 31 OLX7/067-2RW 31 OLX7/067-2RWA5 31 OLX7/067-20SWA 55 OLX7/067-3E 32 OLX7/067-3EC 40 OLX7/067-3ECA1 40 OLX7/067-3ECA5 40 OLX7/067-3ECVA 49 OLX7/067-4EC 42 OLX7/067-4ECA1 42 OLX7/067-4ECA5 42 OLX7/067-6EC 53 OLX7/067BWBK 15 OLX7/067BWBKA5 15 OLX7/067BWBL 15 OLX7/067BWGY 15 OLX7/067BWR 15 OLX7/067BWRA5 15 OLX7/067BWW 15 OLX7/067BWWA5 15 OLX7/067EW 15 OLX7/067EWA5 15 OLX7/067-2ERBBA5 32 OLX7/085-1BK 23 OLX7/085-1R 23 OLX7/085-2EC 38 OLX7/085-2ECA1 38 OLX7/085-2ECA5 38 OLX7/085-2ERB 33 OLX7/085-2ERBA5 33 OLX7/085-2RB 33 OLX7/085-2RW 33 OLX7/085-3EC 41 OLX7/085-3ECA5 41 OLX7/085-4EC 43 OLX7/085-4ECA1 43 OLX7/085-4ECA5 43 OLX7/085BWBK 15 Page OLX7/085BWBL 15 OLX7/085BWBLA5 15 OLX7/085BWEW 15 OLX7/085BWEWA5 15 OLX7/085BWR 15 OLX7/085BWW 15 OLX7/104-1BK 24 OLX7/104-1R 24 OLX7/104-1RA5 24 OLX7/104-2EC 39 OLX7/104-2ECA1 39 OLX7/104-2ECA5 39 OLX7/104-2ERB 34 OLX7/104-2ERBA5 34 OLX7/104-2RB 34 OLX7/104-3EC 41 OLX7/104-3ECA1 41 OLX7/104-3ECA5 41 OLX7/104-4EC 43 OLX7/104-4ECA1 43 OLX7/104-4ECA5 43 OLX7/104BWBK 16 OLX7/104BWBKA5 16 OLX7/104BWBL 16 OLX7/104BWEW 16 OLX7/104BWEWA5 16 OLX7/104BWR 16 OLX7/104BWRA5 16 OLX7/104BWW 16 OLX7/135-1BK 24 OLX7/135-1BKA5 24 OLX7/135-1R 24 OLX7/135-1RA5 24 OLX7/135-2EC 39 OLX7/135-2ECA1 39 OLX7/135-2ECA5 39 OLX7/135-2ERB 35 OLX7/135-2ERBA5 35 OLX7/135-2RB 35 OLX7/135-2SWA 46 OLX7/135-3EC 41 OLX7/135-3ECA5 41 OLX7/135-3SWA 46 OLX7/135-4EC 44 OLX7/135-4ECA1 44 OLX7/135-4ECA5 44 OLX7/135-4SWA 46 OLX7/135BWBK 16 OLX7/135BWBKA5 16 OLX7/135BWBL 16 OLX7/135BWEW 16 OLX7/135BWEWA5 16 OLX7/135BWR 16 OLX7/135BWRA5 16 OLX7/135BWW 16 OLX7/170-1BK 25 OLX7/170-1BKA5 25 OLX7/170-1R 25 OLX7/170-1RA5 25 OLX7/170-2EC 39 OLX7/170-2ECA5 39 OLX7/170-2ERB 36 OLX7/170-2ERBA5 36 OLX7/170-2RB 36 OLX7/170-2RBA5 36 Page OLX7/170-2SWA 46 OLX7/170-3EC 41 OLX7/170-3ECA5 41 OLX7/170-3SWA 46 OLX7/170-4EC 44 OLX7/170-4ECA1 44 OLX7/170-4ECA5 44 OLX7/170-4SWA 46 OLX7/170BWBK 17 OLX7/170BWBKA5 17 OLX7/170BWBL 17 OLX7/170BWBLA5 17 OLX7/170BWEW 17 OLX7/170BWEWA5 17 OLX7/170BWR 17 OLX7/170BWRA5 17 OLX7/170BWW 17 OLX7/170BWWA5 17 OLX7/170NS2 51 OLX7/170XLPEA1 26 OLX7/170XLPEA5 26 ALCAW16 62 ALCAW20 62 ALCAW25 62 ALCAW32 62 ALCAW40 62 ALCAW50 62 ALCAW63 62 ALCAW75 62 ALCAW90 62 ALCEMC16 69 ALCEMC20 69 ALCEMC25 69 ALCEMC32 69 ALCEMC40 69 ALCEMC50 69 ALCEMC63 69 ALCEMC75A 69 ALCEMC75B 69 ALCHAW20 64 ALCHAW32A 64 ALCHAW32B 64 ALCHAW40A 64 ALCHAW40B 64 ALCHAW50A 64 ALCHAW50B 64 ALCHAW63A 64 ALCHAW63B 64 ALCHAW75A 64 ALCHAW75B 64 ALCHAW90A 64 ALCHAW90B 64 ALCHUW25 65 ALCHUW32 65 ALCHUW40 65 ALCHUW50 65 ALCHUW63 65 ALCHUW75 65 ALCHUW90 65 ALCPLN75 85 ALCPLN90 85 ALCPLN ALCPLN ALCUW12 63 ALCUW

92 Index - By Page ALCUW20 63 ALCUW25 63 ALCUW32 63 ALCUW40 63 ALCUW50 63 ALCUW63 63 ALCUW75 63 OLXJSF1.3GLBK1 58 OLXJSF4GLBK OLXJSF6GLBK OLXJSF10GLBK ALCHAW25A 64 ALCHAW25B 64 ALCHUW20A 65 ALCHUW20B 65 TRFMG12 74 TRFMG16 74 TRFMG20 74 TRFMG25 74 TRFMG32 74 TRFMG40 74 TRFMG50 74 OLX19/135XLPEHD 25 OLX285/040XLPEHD 25 OLX259/067XLPEHD 25 ALCHAW20-B 70 ALCHAW25A-B 70 ALCHAW25B-B 70 ALCHAW32A-B 70 ALCHAW32B-B 70 ALCHAW40A-B 70 ALCHAW40B-B 70 ALCHAW50A-B 70 ALCHAW50B-B 70 ALCHAW63A-B 70 ALCHAW63B-B 70 ALCHAW75A-B 70 ALCHAW75B-B 70 ALCHAW90A-B 70 ALCHAW90B-B 70 OLX19/214-3CSWAHVRD 53 OLX936/030XLPEBE 25 OLX936/030XLPERD 25 OLX735/050XLPEHDBE 25 OLX735/050XLPEHDRD 25 OLX19/135BERA1 17 OLX19/135EWA1 17 OLX19/153XLPEA5 27 OLX7/050-2ECC.6/1KV 38 OLX7/050-2ECSWA.6/1KV 46 OLX7/050-3ECSWA.6/1KV 46 OLX7/050-4ECC.6/1KV 42 OLX7/050-4ECCA9 42 OLX7/050-4ECSWA.6/1KV 46 OLX7/067-2EC.6/1KV 38 OLX7/067-2ECSWA.6/1KV 46 OLX7/067-2ERB OLX7/067-3EC.6/1KV 40 OLX7/067-3ECSWA.6/1KV 46 OLX7/085-2EC.6/1KV 38 OLX7/085-2ECSWA.6/1KV 46 OLX7/085-3EC.6/1KV 41 OLX7/085-4EC.6/1KV 44 OLX7/085-4ECSWA.6/1KV 46 OLX7/104-3EC.6/1KV 41 Page OLX7/104-3ECSWA.6/1KV 46 OLX7/104-4EC.6/1KV 44 OLX7/104-4ECSWA.6/1KV 46 OLX7/104-2EC.6/1KV 39 OLX7/104-2ECSWA.6/1KV 46 OLX7/135-2RBOR 35 OLX7/170-2RBOR 36 OLX7/170-2RBORA5 36 OLX7/ OLX7/170XLPE 26 OLX936/030XLPE 25 OLX24/020-11EC 54 OLX32/020-11EC 54 OLX30/025-11EC 54 OLX32/020-17EC 54 OLX24/020-6EC 54 OLX32/020-6EC 54 OLX30/025-6EC 54 ALCAW20SB 62 ALCAW20MR 62 ALCAW20UR 62 OLXJSC5WT6CB20 58 OLX37/225-3ECXLPE 48 OLXJSC2WT6CB30 58 OLXJD2PISB30 58 OLXJSF20CL1 57 OLXJTCD28A9002BKAA 56 OLXJRS1502A5 51 OLXJCAT5EFPA3 55 OLXJDW1PRDWTA2 57 OLX7/104-2RW 34 ALC124MZ00 83 ALC124M11 82 ALC124EG ALC124EG ALC124MZ0 83 ALC124M12 82 ALC124M13 82 ALC124M14 82 ALC124M15 82 ALC124M16 82 ALC133Y00 78 ALC124EG80 79 ALC124EG ALC124EG ALC126PS0 87 ALC126PS1 87 ALC126PS2 87 ALC126PS3 87 ALC126PS4 87 ALC126PS5 87 ALC126PS6 87 OLX285/040-3C 52 ALCBRGM20 71 OLX30/025-2EC 37 OLX50/025-2EC 37 OLX56/030-2EC 37 OLX50/025-3EC 37 OLX56/030-3EC 37 OLX84/030-3EC 37 OLX128/040-3EC 37 OLX200/040-3EC 37 OLX50/025-4EC 37 OLX56/030-4EC 37 OLX84/030-4EC 37 Page ALCHAW20LR 64 ALCUW20A 63 ALCSG0S 77 ALCHAW20SB 64 ALCUW16S 63 ALCAW50L 62 ALCAW63L 62 ALCEMC12 69 ALCEMC75C 69 ALCHAW20LRB 70 ALCHAW20SB-B 70 ALCHUW20SB 65 ALCSG1S 77 ALCSG2L 77 ALCSG3L 77 ALCSG6L 77 ALCSG8S 77 ALCSG9S 77 ALCSG10S 77 ALCSG11S 77 ALCUW ALCUW120A 63 ALCUW120B 63 ALCFW75 75 OLX46/020-2CR0.6/1KV 50 OLX46/020-3CR 50 OLX46/020-4CR 50 OLX76/020-2CR 50 OLX735/0501EC 25 OLXJCAT6FPA3 55 ALC126PS ALCBRGM12 71 ALCBRGM16 71 ALCBRGM16-SS 72 ALCBRGM20-SS 72 ALCBRGM25 71 ALCBRGM25-SS 72 ALCBRGM32 71 ALCBRGM32-SS 72 ALCBRGM40 71 ALCBRGM40-SS 72 ALCBRGM50 71 ALCBRGM50-SS 72 ALCBRGM63 71 ALCBRGM63-SS 72 ALCHUW20A-LTA20 66 ALCHUW20B-H 67 ALCHUW20B-LTA25 66 ALCHUW20SB-H 67 ALCHUW20SB-LTA16 66 ALCHUW25-H 67 ALCHUW25-LTA32 66 ALCHUW32-H 67 ALCHUW32-LTA40 66 ALCHUW40-H 67 ALCHUW40-LTA50 66 ALCHUW50-H 67 ALCHUW50-LTA63 66 ALCIP ALCIP ALCIP38 81 ALCSG1BS 77 ALCSG2LB 77 ALCSG2S 77 ALCSG2SB 77 90

93 Index - By Page ALCSG3S 77 ALCSG3SB 77 ALCSG4S 77 ALCSG5S 77 ALCSG6S 77 ALCSG7S 77 ALCEMC20-LN 86 ALCEMC25-LN 86 ALCEMC63-LN 86 ELMEMC16 68 ELMEMC20 68 ELMEMC20G3 68 ELMEMC25 68 ELMEMC32 68 ELMEMC40 68 ELMEMC50 68 ELMEMC63 68 OLX24/020-1PR 60 OLX24/020-2PR 60 OLX24/020-4PR 60 OLX24/020-6PR 60 OLX24/020-10PR 60 OLX46/020-1PR 60 OLX46/020-2PR 60 OLX46/020-6PR 60 OLX46/020-10PR 60 ALC124EG ALC124EG ALC124EG ALC124EG ALC124EG ALC125KG ALC125KG ALC125KG ALC133Y0 78 ALC133Y1 78 ALC133Y2 78 ALC133Y3 78 ALC133Y ALC133Y4 78 ALC133Y ALC133Y5 78 ALC133Y6 78 ALCBRGM10 71 ALCBRGM6 71 ALCBRGM8 71 ELMEMC20S 68 ELMEMC63L 68 ALCAW90B 62 ELMEMC12 68 ALCSG4SB 77 ALCSG5SB 77 ALCSG6LB 77 ALCSG6SB 77 ALCSG7SB 77 ALCSG8SB 77 ALCSG9SB 77 OLX7/085-2ECBKA5 33 OLX7/050-4ECCBK 43 OLX7/067-4ECCBK 42 OLX7/067-4ECCO 42 OLX7/050-2ECCBK 38 OLX7/050-8ECBK 53 OLX7/050-50ECBK 54 OLX18/147-4ECXLPE 48 Page OLX18/170-4ECXLPE 48 OLX18/195-4ECXLPE 48 OLX18/235-4ECXLPE 48 OLX19/252-4ECXLPE 48 OLX37/203-4ECXLPE 48 OLX37/252-4ECSWAXLPE 47 OLX7/135-3ECVA 49 OLX37/225-3ECVA 49 OLX37/252-3ECVA 49 OLX37/288-3ECVA 49 OLX18/170-3ECXLPE 48 OLX18/195-3ECXLPE 48 OLX18/235-3ECXLPE 48 OLX19/252-3ECXLPE 48 OLX37/203-3ECXLPE 48 OLX37/252-3ECXLPE 48 OLX18/170-3ECSWAXLPE 47 OLX18/195-3ECSWAXLPE 47 OLX18/235-3ECSWAXLPE 47 OLX18/252-3ECSWAXLPE 47 OLX37/203-3ECSWAXLPE 47 OLX37/225-3ECSWAXLPE 47 OLX37/252-3ECSWAXLPE 47 OLX76/020-4CR 50 OLX630/050XLPEBK 21 OLX756/050XLPEBK 21 OLX924/050XLPEBK 21 OLX1190/050XLPEBK 21 OLX1491/050XLPEBK 21 OLX2016/050XLPEBK 21 OLX2520/050XLPEBK 21 OLX18/170-4CXLPEURD 48 OLX7/170-4CXLPEURD 52 OLXIEG OLXJSF2.5GLBK1 58 OLX37/288BWEW 18 OLX19/214BWBARE 18 OLX1190/050-1CR 20 OLX630/050-1CR 20 OLX1296/030-1CR 20 OLX972/030-1CR 20 OLX696/030-1CR 20 OLX816/020-1CR 20 OLX37/202-1CACU 28 OLX1296/030XLPEBK 21 OLX37/225-4ECXLPE 48 OLX37/252-4ECXLPE 48 OLX37/288-4ECXLPE 48 OLX19/178-3CSWA 47 OLX7/067-2ECSWA 46 OLX3304/050XLPEBK 21 OLX972/030XLPEBK 21 OLX380/040-3C 52 OLX37/178-3CSWAXLPEHVRD 53 OLX24/020-2CR0.6/1KV 50 OLX24/020-3CR 50 OLX24/020-4CR0.6/1KV 50 OLX348/020-1CR 20 OLX528/020-1CR 20 OLX1179/020-1CR 20 OLX56/030-2ECR 50 OLX56/030-4ECR 50 OLX56/030-3ECR 50 OLX32/020-3CR 50 OLX32/020-4CR 50 Page OLX32/020-2CR 50 OLX46/020-2ECR 50 OLX46/020-3ECR 50 OLX46/020-4ECR 50 OLX76/020-2ECR 50 OLX76/020-3ECR 50 OLX81/030-2ECR 50 OLX81/030-3ECR 50 OLX81/030-4ECR 50 OLX756/050-1CR 20 OLX924/050-1CR 20 OLX1491/050-1CR 20 OLX2016/050-1CR 20 OLX2520/050-1CR 20 OLX76/020-4ECR 50 OLX348/020-2ECR 50 OLX348/020-3ECR 50 OLX348/020-4ECR 50 OLX528/020-2ECR 50 OLX528/020-4ECR 50 OLX816/020-4ECR 50 OLX1179/020-4ECR 50 OLX696/030-4ECR 50 OLX528/020-3ECR 50 OLX3304/050-1CR 20 OLX528/020XLPE-EW 21 OLX816/020XLPEBK 21 OLX816/020XLPE-EW 21 OLX1179/020XLPEBK 21 OLX1179/020XLPE-EW 21 OLX696/030XLPEBK 21 OLX696/030XLPE-EW 21 OLX972/030XLPE-EW 21 OLX1296/030XLPE-EW 21 91

94 REFERENCE SECTION TABLE OF CONTENTS FLEXIBLE CABLE CORD COLOURS... CURRENT RATINGS - FLEXIBLE CORDS... CABLE SELECTION... CABLE INSTALLATION... GENERAL APPLICATION DATA... ABBREVIATIONS... R1 R2 R3 - R4 R5 R6 - R16 R17

95 REFERENCE SECTION FLEXIBLE CABLE CORD COLOURS Colour sequences are valid for standard light ordinary and heavy duty cords. Preferred Core Colours For cords not installed as fixed wiring: Olex Colour Code 2 Core Brown, Light Blue JJ 3 Core Brown, Light Blue, Green/Yellow KA 4 Core Brown, Light Blue, White, Green/Yellow DV 5 Core Brown, Light Blue, Orange, White, Green/Yellow FS Light blue is normally used as a neutral (where applicable). Information supplied courtesy of Cooper Olex Cables Electrical Australia R1

96 REFERENCE SECTION CURRENT RATINGS FLEXIBLE CORDS Electrical Data & Current Ratings In accordance with AS/NZS Nominal conductor area mm 2 Current carrying capacity A Maximum DC resistance at 20 C Multicore Ω/km Voltage drop Single phase mv/a.m Voltage drop Three phase mv/a.m PACW TACW Where a flexible cord is wound on a drum, multiply current carrying capacities by the following factor: Number of layers: Derating factor: Information supplied courtesy of Cooper Olex Cables Electrical Australia R2

97 REFERENCE SECTION CABLE SELECTION The size and type of cable required for a given application should be selected according to the following criteria: 1. Current carrying capacity and voltage drop Conductor sizes are nominated by the Wiring Rules (AS/NZS 3000) for the wiring of socket outlets and lighting circuits in domestic and commercial buildings. For other types of installations: a) The cable must be capable of carrying the maximum continuous load of the circuit, with due regard for the insulating material and conditions of installation. b) The voltage drop from the consumer s terminals to any point in the installation must not exceed 5% of the nominal system voltage. Simplified tables of current ratings and voltage drops for commonly used cables are given on pages In large installations where current ratings are critical, attention is drawn to the comprehensive tables given in AS/NZS : Installation conditions Olex cables are available for aerial, underground and submarine installations as well as in conduit, on racks or trays in air. Special constructions available include: Brass or copper taped or nylon sheathed cables for resistance to termite and marine borer. Steel wire armoured for areas where there is a high risk of mechanical damage. Alsecure fire performance low smoke halogen free cables for emergency power and lighting and other purposes in areas of high fire risk. Alsecure Ceramifiable is a world first in fire performance cable with a polymer layer that hardens into a protective shield when exposed to fire. Versolex, the new high performance multipurpose cable for fixed & flexible applications. Lead alloy sheathing as a barrier to moisture or hydrocarbons. Alsecure Envirolex cables with low smoke emission and no halogen or lead for environmentally sensitive areas. Flexolex cables for flexible applications and where flexibility provides advantages during installation. Information supplied courtesy of Cooper Olex Cables Electrical Australia R3 3. Cable insulating and sheathing materials Standard Olex cables are available in a number of materials, including: Olex (Polyvinyl Chloride) insulated and sheathed cables are the economic choice for general wiring. They are resistant to occasional contact with most oils and solvents, clean and easy to handle and coloured to assist phase identification. is suitable for operating temperatures up to 90 C and 90 HT, subject to the requirements of AS/NZS is inherently resistant to ultraviolet radiation and although some colours may fade the material will not significantly degrade due to the effects of sunlight and weather, maintaining its physical integrity if not physically abused. Care should be taken where cables are subjected to extremes of temperature or contact with crude petroleum, caustic materials or aromatic solvents. Olex synthetic rubber (EPR/CPE) insulated and sheathed cables are more flexible and have better resistance to oils and solvents than. Olex EPR (Ethylene Propylene Rubber), while not oil resistant, has excellent dielectric properties and high voltage grades are available for cables up to 33kV. In addition, EPR is halogen free and therefore does not emit toxic or corrosive by-products when burnt. Olex CPE (Chlorinated Polyethylene) is an excellent flexible insulation and heavy duty sheathing material. Although having lower insulation resistance than EPR it is suitable for low voltage cable insulation and is used as such in welding cables because of its oil resistance. For special purposes a sheath of Olex EA (Ethylene Acrylic) material can be provided subject to special order. This material is halogen free, extremely flame retardant and has better oil resistance than CPE. EPR/EA cables can safely be used in-plenum air ducts and other applications where high flame retardance and freedom from acid gas emission is required. EPR, CPE and EA are all suitable for continuous operation up to 90 C. XLPE (Cross-linked Polyethylene) has the highest dielectric properties of Olex insulation materials, and is used in a wide range of cables from low voltage up to 275kV. It is halogen-free and also free of heavy metals such as lead and antimony. It has low smoke and toxicity when burned. It is a suitable alternative to and is becoming more widely specified where there are environmental concerns.

98 REFERENCE SECTION CABLE SELECTION Ceramifiable An insulation material that is polymeric in its normal state, but converts to an insulating ceramic that provides circuit integrity when burned. Normal state properties are suitable for continuous operation at 110 C. It is halogen-free, lead and antimony-free, and does not emit toxic or corrosive products when burned. HFS-110-TP. Olex offers this thermoplastic, halogen and heavy metal-free sheathing as an alternative to when these characteristics are required. The material has reasonable oil resistance and flexibility, with a high resistance to spread of fire. Information supplied courtesy of Cooper Electrical Australia R4

99 REFERENCE SECTION CABLE INSTALLATION In all cases, cables must be installed in compliance with the safety requirements of AS/NZS Particular attention should be paid to the following: Current carrying capacities of cables depend on the temperature of the air or ground in which they are installed and the degree to which heat can escape. Except for a group of single core cables carrying the phase currents of a circuit, cables should be spaced to allow heat to escape. Wherever cables are installed in close proximity, especially in the ground, or enclosed in such a way as to restrict heat loss, their current carrying capacities must be reduced using a derating factor appropriate to the situation. For minimum voltage drop single core cables carrying the phase currents of a single circuit should be installed as closely as possible together, to minimise inductive reactance. The preferred formation for three phase conductors is a trefoil or cloverleaf pattern although flat formation may also be used. Sheaths should be in contact with one another in either case. A single core cable generates an alternating magnetic field around itself which can cause large increases in voltage drop and power loss due to transformer effect when ferrous metal (iron and steel) is allowed to encircle the cable. Steel racking or ladder will not cause trouble, but the following must be observed: Steel wire or tape armour is never used on a single core cable for AC use. Where three single phase cables pass through a steel bulkhead all must pass through the same hole. Where glanding is required it is usual to cut out a panel and replace this with a non-ferrous (metal or plastic) plate in which the three or four glands are mounted. Should plastic or non-ferrous gland plate material not be available, an alternative is to cut a slot (hacksaw blade width is adequate) between adjacent gland holes. This will provide physical and electrical isolation for the eddy current paths and stop the cable from overheating. Information supplied courtesy of Cooper Olex Cables Electrical Australia R5

100 REFERENCE SECTION GENERAL APPLICATION DATA Minimum size of copper earthing conductors. Nominal area active conductors mm 2 For copper active conductors mm 2 For aluminium active conductors mm * * *Refer Wiring Rules, AS/NZS 3000 regarding 1.5 earthing conductors. Maximum operating temperatures for various types of cable insulants. Type Normal use* C Max permissible C Thermoplastic () V V V-90HT 90* 90** Elastomer R-EP R-CPE R-S Polyethylene Low Density Cross linked polyethylene (X-90) Olex Ceramifiable R-E *As defined in AS/NZS **V-90HT may be operated up to 105ºC for restricted periods only. Information supplied courtesy of Cooper Olex Cables Electrical Australia R6

101 REFERENCE SECTION GENERAL APPLICATION DATA DC Conductor resistances for insulated cables for fixed installations. Solid, stranded conductors; also refer to AS/NZS Nominal conductor area mm 2 Conductor type *Single strand conductors only (solid). **Single core values. Single Core or Multicore Maximum DC resistance at 20 C/Ω/km Plain Tinned Aluminium 0.5 Solid * Solid Stranded * Solid Stranded * Solid Stranded Stranded Stranded Stranded Stranded Stranded Stranded Stranded Stranded Stranded Stranded Stranded Stranded Stranded Stranded Stranded Stranded ** ** ** 630 Stranded ** ** ** Information supplied courtesy of Cooper Olex Cables Electrical Australia R7

102 REFERENCE SECTION GENERAL APPLICATION DATA Useful 3 phase formulae. kw = kva x pf kw = hp x x Eff kw = Line Amps x Line Volts x1.732 x pf 1000 kva = kw pf kwa = hp x x Eff x pf kwa = Line Amps x Line Volts x Line Amps = kw x 1000 Line Volts x x pf Line Amps = kwa x 1000 Line Volts x Line Amps = hp x 746 Line Volts x x Eff x pf Horsepower (hp) = kw x1000 x Eff 746 Horsepower (hp) = kva x 1000 x Eff x pf 746 Horsepower (hp) = Line Amps x Line Volts x x Eff x pf 746 Line Current = 5 5 x Supply Voltage x 100 Route Length x Voltage Drop Factor Information supplied courtesy of Cooper Olex Cables Electrical Australia R8

103 REFERENCE SECTION GENERAL APPLICATION DATA American conductor sizes M.C.M. & A.W.G. conversion to mm 2 M.C.M. mm 2 M.C.M. mm Note: The American term mil refers to a milli-inch (1/1000N) NOT a millimetre. A Circular Mil. (C.M.) is the area of a circle 1 mil in diameter. The term M.C.M. refers to an area of 1000 Circular Mils and is the same as kcmil. 1.0mm2 is approximately 1974 Circular Mils. A.W.G. Diameter mm mm 2 A.W.G. Diameter mm mm Note: The American Wire Gauge (AWG) was originally known as the Brown & Sharp (B&S) Gauge and both terms are synonymous. The gauge number can apply to a single wire or to a stranded or bunched conductor. The cross-sectional areas given apply to single wire only. The larger gauges are sometimes written using a number to denote the number of zeroes, e.g. 0 gauge can be written 1/0 and 000 as 3/0. Information supplied courtesy of Cooper Olex Cables Electrical Australia R9

104 REFERENCE SECTION GENERAL APPLICATION DATA Cable minimum installed bending radii. Type Voltage Instal. During instal. Fixed wiring or Elastomer or XLPE (1) Single and Multicore (a) Overall diameter to & including 25mm 0.6/1kV 4 6 (b) Overall diameter over 25mm 0.6/1kV 6 9 (2) Multicore SWA or metal tape 0.6/1kV (3) Solid aluminium, compacted or sector 0.6/1kV 8 12 Flexible Cords or Elastomer 250/440V 4 0.6/1kV 4 Flexible Cables or Elastomer (incl. Versolex ) 0.6/1kV 4 Lead Sheath or Elastomer 0.6/1kV Paper Insulated Single Up to 11kV Multicore Up to 11kV Single Core 22kV Multicore 22kV Single Core 33kV Multicore 33kV Trailing Elastomer (1) Single and Multicore 1.1kV 6 (2) Single and Multicore 3.3kV & above 12 Welding or Elastomer 0.6/1kV 6 Nylon Covered All Cables HDPE Sheathed All Cables Information supplied courtesy of Cooper Olex Cables Electrical Australia R10

105 REFERENCE SECTION GENERAL APPLICATION DATA Motor current table, Amperes (approx). Power kw hp Single phase 230V Three phase 400V Single phase 240V Three phase 415V Information supplied courtesy of Cooper Olex Cables Electrical Australia R11

106 REFERENCE SECTION GENERAL APPLICATION DATA Number of Cables in Conduit. Recommended maximum number of thermoplastic insulated unsheathed single core 0.6/1kV copper or aluminium cables Nominal size of conduit (mm) Nominal area mm LD LD HD LD HD LD HD LD HD LD HD LD HD HD Notes: 1. For flexible conduits, the recommendations are based on conduits used without fittings or with fittings only at the ends of the conduit run. Where intermediate fittings are used in a run of flexible conduit, an appropriate reduction should be made in the number of cables drawn into the conduit. 2. One earth wire of appropriate size, as determined by the requirements of AS/NZS 3000, may be inserted in all conduits, provided that its insertion does not prevent easy drawing in of cables. 3. Table suitable for use with Olex manufactured product only. Information supplied courtesy of Cooper Olex Cables Electrical Australia R12

107 REFERENCE SECTION GENERAL APPLICATION DATA Number of Cables in Conduit. Calculated maximum number of thermoplastic insulated and sheathed single core copper or aluminium cables permitted in /750V as/nzs /1 V AS/NZS Nominal size of conduit (mm) Nominal area mm HD HD HD HD HD HD HD HD HD Notes: 1. For flexible conduits, the recommendations are based on conduits used without fittings or with fittings only at the ends of the conduit run. Where intermediate fittings are used in a run of flexible conduit, an appropriate reduction should be made in the number of cables drawn into the conduit. 2. One earth wire of appropriate size, as determined by the requirements of AS/NZS 3000, may be inserted in all conduits, provided that its insertion does not prevent easy drawing in of cables. 3. Table suitable for use with Olex manufactured product only. Information supplied courtesy of Cooper Olex Cables Electrical Australia R13

108 REFERENCE SECTION GENERAL APPLICATION DATA Cables in conduit and pipe space factors. One cable in conduit or pipe 50% Two cables in conduit or pipe 33% Three or more in conduit or pipe 40% Notes: 1. The above values should not be exceeded. Maximum safe pulling tension. Maximum tension kn per conductor Conductor Conductor Maximum tension kn per conductor area mm 2 Aluminium area mm 2 Aluminium (1kN = 102kgf) Information supplied courtesy of Cooper Olex Cables Electrical Australia R14

109 REFERENCE SECTION GENERAL APPLICATION DATA Maximum number of cables Recommended maximum number of thermoplastic insulated unsheathed single core 0.6/1 kv or Aluminium cables permitted in metallic and nonmetallic conduit or pipe. Notes; 1. For flexible conduits, the recommendations are based on conduits used without fittings or with fitting only at the ends of the conduit run. Where intermediate fittings are used in a run of flexible conduit, an appropriate reduction should be made in the number of cables drawn into the conduit. 2. One earth wire of appropriate size, as determined by the requirements of AS/ NZS3000, may be inserted in all conduits, provided that its insertion does not prevent easy drawing in of cables. Nominal area mm 2 16 LD 20 LD 20 HD 25 LD 25 HD Nominal size of conduit (mm) 32 LD 32 HD LD 40 HD 50 LD 50 HD 63 LD 63 HD 65 HD 80 HD Maximum number of cables Recommended maximum number of thermoplastic insulated and sheathed single core or Aluminium cables permitted in metallic and non-metallic conduit or pipe. 1.0 to 25mm 2 450/750V to AS/ NZS to 630mm 2 0.6/1 kv to AS/ NZS Notes; 1. For flexible conduits, the recommendations are based on conduits used without fittings or with fitting only at the ends of the conduit run. Where intermediate fittings are used in a run of flexible conduit, an appropriate reduction should be made in the number of cables drawn into the conduit. 2. One earth wire of appropriate size, as determined by the requirements of AS/ NZS3000, may be inserted in all conduits, provided that its insertion does not prevent easy drawing in of cables. Nominal area mm 2 20 HD 25 HD 32 HD Nominal size of conduit (mm) 40 HD 50 HD 63 HD 65 HD 80 HD 100 HD 150 HD R15

110 REFERENCE SECTION GENERAL APPLICATION DATA Conduction resistances Conductor resistances for insulated cables for fixed installations. Solid, stranded conductors; also refer to AS1125. Nominal conductor area mm 2 Conductor type Single Core or Multicore Maximum DC resistance at 20 C/n/km Tinned Plain Aluminium 0.5 Solid * Solid Stranded * Solid Stranded * Solid Stranded Stranded Stranded Stranded Stranded Stranded Stranded Stranded Stranded Stranded Stranded Stranded Stranded Stranded Stranded Stranded Stranded Stranded Minimum size copper earthing conductors Nominal area ACTIVE conductors mm 2 For COPPER active conductors mm2 For ALUMINIUM active conductors mm * * *Refer Wiring Rules. AS/NZS3000 regarding 1.5 earthing conductors *Single strand conductors only (solid). R16

111 REFERENCE SECTION ABBREVIATIONS A.m Ampere metre ABC aerial bundled cable AC alternating current Al aluminium AS Australian Standard C core C degree Celsius CPE Chlorinated Polyethylene CSA cross-sectional area CSP Chlorosulphonated Polyethylene Cu copper db decibel DC direct current E earth EA Ethylene Acrylic Eff efficiency ELV Extra Low Voltage EPR Ethylene Propylene Rubber HD hard drawn H.D. heavy duty HFS-90-TP halogen free sheath 90 C thermoplastic HF-110-R halogen free 110 C rubber (sheath) hp horsepower HR heat resistant HRC high rupture capacity ISDN Integrated Services Digital Network kg kilogram kn kilonewton kv kilovolt kva kilovoltamp kw kilowatt LAN local area network L.D. light duty mm millimetre MM Multi Mode (Fibre) nf/km nanofarad/kilometre OD outside diameter O.D. ordinary duty PACW plain annealed copper wire PE Polyethylene pf power factor pf/m picofarad/metre PILC paper insulated lead covered Polyvinyl Chloride R-CPE-90 rubber Chlorinated Polyethylene 90 C R-EP-90 rubber Ethylene Propylene 90 C R-HF-110 rubber halogen free 110 C (insulation) SM Single Mode (Fibre) SWA steel wire armoured TACW tinned annealed copper wire TPE thermoplastic elastomer UTP unshielded twisted pairs V volt V C rated V C rated V-90HT 90 C rated 105 C for restricted periods X-HF-90 XLPE halogen free 90 C X-90 Cross-linked Polyethylene Information supplied courtesy of Cooper Olex Cables Electrical Australia R17

112 BRANCH LOCATIONS OUR AUSTRALIA WIDE NETWORK VICTORIA BRANCH PHONE FAX L&H* AIRPORT WEST UNIT 1&2/2-4 KINGS ST (03) (03) L&H* ALBURY 474 MACAULEY ST (02) (02) L&H BALLARAT (8am-12am) 12 ARARAT ST (03) (03) AUS BALLARAT UNIT 4/5 CARAVAN ST (03) (03) L&H * BAYSWATER (8am-12am) LOT 12/260 CANTERBURY RD (03) (03) L&H BENDIGO (8am-12am) 19 DEBORAH ST (03) (03) L&H BULLEEN (8am-12am) 204 BULLEEN RD (03) (03) AUS CAMPBELLFIELD 366 BARRY RD (03) (03) L&H* CASTLEMAINE UNIT 1/2-4 RAILWAY AVE (03) (03) L&H COBURG (7am-11am) 35 ESSEX ST (03) (03) L&H DANDENONG (8am-12am) FACTORY 1/2 GREENS RD (03) (03) L&H Delocombe 28 Wiltshire Ln (03) (03) AUS DOVETON UNIT 2&3/37 PRINCES HIGHWAY (03) (03) L&H* DRYSDALE UNIT 20/34 MURRADOC RD (03) (03) L&H* EPPING UNIT 2/222 COOPER ST (03) (03) L&H FRANKSTON (8am-12am) UNIT 1/37 WELLS RD (03) (03) L&H GEELONG 200 LATROBE TCE (03) (03) AUS GEELONG 304 THOMPSONS RD (03) (03) L&H HAMILTON 15 PECK ST (03) (03) L&H HOPPERS CROSSING (8am-12am) 94 OLD GEELONG RD (03) (03) L&H HORSHAM 13 SLOSS ST (03) (03) L&H LILYDALE MAIN RD (03) (03) L&H MILDURA (8am-12am) 270 ETIWANDA AVE (03) (03) L&H * MOORABBIN (8am-12am) WICKHAM RD (03) (03) L&H MORNINGTON 12 Bruce st (03) (03) L&H MORWELL 9 CHICKERELL ST (03) (03) L&H MULGRAVE 36 GEDDES ST (03) (03) L&H NUNAWADING UNIT 2/38-42 ROOKS RD (03) (03) L&H* PAKENHAM 1/1225 KOO WEE RUP RD (03) (03) L&H PORTLAND 4 KUNARA CRES (03) (03) L&H* PRESTON 44 QUINN ST (03) (03) L&H RINGWOOD CNR MOLAN ST & YALLOURN PDE (03) (03) L&H SALE 22 BOND ST (03) (03) L&H SCORESBY 71 RUSHDALE ST (03) (03) L&H SHEPPARTON 9 CALLISTER ST (03) (03) L&H * SOUTH MELBOURNE (8am-12am) 142 DORCAS ST (03) (03) L&H SUNSHINE UNIT 6/34 MCINTYRE RD (03) (03) AUS SUNSHINE WEST UNIT 11&12/ FAIRBAIRN RD (03) (03) L&H SWAN HILL 4 QUEEN ST (03) (03) L&H * THOMASTOWN (8am-12am) 26 DALTON RD (03) (03) L&H TRARALGON 89 PRINCES ST (03) (03) L&H WANGARATTA CHISHOLM ST (03) (03) Tasmania BRANCH PHONE FAX AUS BURNIE 20 WELLINGTON ST (03) (03) L&H DEVONPORT 31 DON RD (03) (03) L&H * HOBART (8am-12am) ARGYLE ST (03) (03) aus HOBART 6 LAMPTON AVE (03) (03) L&H LAUNCESTON (8am-12am) 25 FREDERICK ST (03) (03) L&H Lawrence & Hanson AUS Auslec Branch open Saturday (trading hours) * Data & Comms specialist branch Industrial Outlet Scan for store locator & map

113 BRANCH LOCATIONS OUR AUSTRALIA WIDE NETWORK NEW SOUTH WALES BRANCH PHONE FAX L&H* ALEXANDRIA UNIT 2/6-8 HUNTLEY ST (02) (02) L&H* ARTARMON 13/87 RESERVE RD (02) (02) L&H BALLINA (7am-10am) 33 SHEATHER ST (02) (02) L&H BANKSTOWN 1 MARIGOLD ST (02) (02) L&H BATHURST 122 BENTINCK ST (02) (02) L&H BLACKTOWN (7am-12am) UNIT 1/3 CHICAGO AVE (02) (02) AUS BROKEN HILL (7:30am-12am) 352 BLENDE ST (08) (08) L&H BROOKVALE UNIT 4H/9-13 WINBOURNE RD (02) (02) L&H* CAMPBELLTOWN 1B ROSE ST (02) (02) L&H * CARDIFF (8am-12am) 33 MUNIBUNG RD (02) (02) L&H CASTLE HILL UNIT 1/2 CNR ANELLA & VICTORIA AVE (02) (02) AUS COBAR 15 THIRTEENTH ST (02) (02) L&H COFFS HARBOUR 1/9 SECCOMBE CL (02) (02) L&H DUBBO CNR COBBORA RD & KING ST (02) (02) L&H * FYSHWICK (8am-12am) UNIT 4/3 BARRIER ST (02) (02) L&H GOSFORD (8am-12am) UNIT 1/16 ENTERPRISE CL (02) (02) L&H GOULBURN 21 BRADLEY ST (02) (02) L&H GRIFFITH (8am-12am) 3 FAVELL ST (02) (02) L&H HURSTVILLE UNIT 3/61-63 FOREST RD (02) (02) L&H INVERELL BYRON ST (02) (02) L&H MITCHELL (8am-12am) UNIT 2/67-71 VICARS ST (02) (02) L&H NEWCASTLE 218 MAITLAND RD (02) (02) AUS NEWCASTLE 3 REVELATION CL (02) (02) L&H * NORTHmead unit 3c/6 boundary rd (02) (02) L&H NOWRA 59 GRAHAM ST (02) (02) L&H ORANGE UNIT 5/ MARCH ST (02) (02) AUS ORANGE 1&3/16 ASH ST (02) (02) L&H PAMBULA 35 BULLARA ST (02) (02) AUS PARKES DALTON ST (02) (02) L&H * PENRITH (8am-12am) 96 BATT ST (02) (02) L&H TAMWORTH 103 KABLE AVE (02) (02) L&H * TAREN POINT (8am-12am) 5/ TAREN POINT RD (02) (02) L&H TWEED HEADS SHOP 2B/13 GREENWAY DR (07) (07) L&H WAGGA WAGGA UNIT 1&2/91 COPLAND ST (02) (02) AUS WETHERILL PARK UNIT 1/ VICTORIA ST (02) (02) L&H WINDSOR (8am-12am) UNIT 2/3 BLACKMAN CRES (02) (02) L&H WOLLONGONG CNR KENNY & WEST ST (02) (02) AUS WOLLONGONG 185 BERKELEY RD (02) (02) L&H Lawrence & Hanson AUS Auslec Branch open Saturday (trading hours) * Data & Comms specialist branch Industrial Outlet Scan for store locator & map

114 BRANCH LOCATIONS OUR AUSTRALIA WIDE NETWORK queensland BRANCH PHONE FAX L&H AYR (8am-11am) 101 GRAHAM ST (07) (07) L&H BEENLEIGH UNIT 1/104 HARBURG DR (07) (07) L&H BROWNS PLAINS 13 CENTRAL CT (07) (07) L&H BUNDABERG 14 ELECTRA ST (07) (07) L&H CABOOLTURE (8am-11am) CNR MORAYFIELD RD & GAFFIELD ST (07) (07) L&H CAIRNS (7am-10am) 210 McCORMACK ST (07) (07) L&H CAPALABA 54 NEUMANN RD (07) (07) L&H CHINCHILLA (8am-12am) 12 MALDUF ST (07) (07) L&H COORPAROO 15 BIRUBI ST (07) (07) L&H EMERALD (7am-10am) INDUSTRIAL DR (07) (07) L&H * FORTITUDE VALLEY (8am-11am) 34 CHESTER ST (07) (07) AUS GEEBUNG 410 NEWMAN RD (07) (07) AUS GLADSTONE 63 LORD ST (07) (07) L&H GYMPIE 47 TOZER ST (07) (07) L&H HERVEY BAY (8am-11am) SHOP 1&2 / 6/8 CARLO ST (07) (07) L&H IPSWICH 2 LOWRY ST (07) (07) L&H LAWNTON UNIT 1/10 PAISLEY DR (07) (07) L&H LISMORE UNIT 1/36-38 WYARALLAH RD (02) (02) L&H MACKAY 7 INDUSTRIAL ST (07) (07) L&H* MAROOCHYDORE 10 TRINDER AVE (07) (07) L&H NAMBOUR 17 MITCHELL ST (07) (07) L&H NERANG (7am-11am) UNIT 1/ SPENCER RD (07) (07) L&H NOOSA UNIT 1&2/8 ACTION ST (07) (07) L&H REDCLIFFE 83 ANZAC AVE (07) (07) L&H ROCKHAMPTON (8am-11am) 215 FARM ST (07) (07) L&H * ROCKLEA (7am-12am) 30 MEDWAY ST (07) (07) AUS SALISBURY UNIT 2&3/241 EVANS RD (07) (07) L&H SLACKS CREEK 3347 PACIFIC HIGHWAY (07) (07) L&H SUMNER PARK (7am-10am) 1/57 SPINE ST (07) (07) L&H SURFERS PARADISE (7am-11am) UNIT 1/11 STRATHAIRD RD (07) (07) L&H * TOOWOOMBA (7am-10am) 5-7 MARKELEE ST (07) (07) aus TOOWOOMBA 5-7 MARKELEE ST (07) (07) L&H TOWNSVILLE (7am-11am) 301 BAYSWATER RD (07) (07) AUS TOWNSVILLE UNIT 16/ WOOLCOCK ST (07) (07) L&H YEPPOON 35 TANBY RD (07) (07) Northern territory BRANCH PHONE FAX L&H ALICE SPRINGS (8am-12am) UNIT 1/9 WHITTAKER ST (08) (08) L&H * DARWIN (8am-12am) UNIT 2/524 STUART HIGHWAY (08) (08) L&H KATHERINE (8am-12am) 60 CRAWFORD ST (08) (08) L&H PALMERSTON (8am-12am) UNIT 1/28 TOUPEIN RD (08) (08) L&H Lawrence & Hanson AUS Auslec Branch open Saturday (trading hours) * Data & Comms specialist branch Industrial Outlet Scan for store locator & map

115 BRANCH LOCATIONS OUR AUSTRALIA WIDE NETWORK South australia BRANCH PHONE FAX L&H ADELAIDE 200 GOUGER ST (08) (08) L&H BERRI 25 JELLETT RD (08) (08) L&H CLOVELLY PARK (8am-12am) SOUTH RD (08) (08) L&H* GAWLER LOT 3&4/5 LITTLE PAXTON CT (08) (08) L&H * GLYNDE (8am-12am) 25 GLYNBURN RD (08) (08) L&H KILKENNY CNR REGENCY RD & HUMPHRIES TCE (08) (08) L&H KLEMZIG 300 NORTH EAST RD (08) (08) L&H * KURRALTA PARK (8am-12am) 504 SOUTH RD (08) (08) L&H LONSDALE (8am-12am) CNR ALDERSHOT & O SULLIVAN BEACH RD (08) (08) L&H MOUNT BARKER LOT 20 DIAGONAL RD (08) (08) L&H MOUNT GAMBIER 201 COMMERCIAL ST WEST (08) (08) L&H NURIOOTPA 7 RAILWAY TCE (08) (08) L&H PORT ADELAIDE 2 CLEAVE ST (08) (08) L&H PORT AUGUSTA LOT 4 MAIN NORTH RD (08) (08) L&H PORT LINCOLN (8am-12am) 63 MORTLOCK TCE (08) (08) L&H PORT PIRIE CNR WANDEARAH RD & GREY TCE (08) (08) AUS ROXBY DOWNS 16 GOSSE ST (08) (08) L&H SALISBURY SOUTH (8am-12am) 5 PENTLAND RD (08) (08) AUS WHYALLA 8 COOK ST (08) (08) AUS WINGFIELD 203 CORMACK RD (08) (08) western australia BRANCH PHONE FAX L&H ALBANY 52 SANFORD RD (08) (08) L&H * BALCATTA (8am-12am) UNIT 9/86 ERINDALE RD (08) (08) L&H BELMONT (8am-12am) UNIT 1/92 FRANCISCO ST (08) (08) AUS BROOME UNIT 1/15 BLACKMAN ST (08) (08) AUS BUNBURY (8am-11am) UNIT 2/17 DENNING RD (08) (08) L&H BUSSELTON UNIT 2/151 PONSFORD CHS (08) (08) AUS CANNING VALE 211 BANNISTER RD (08) (08) L&H EMBLETON (8am-12am) 20 EMBLETON AVE (08) (08) AUS GERALDTON 270 PLACE RD (08) (08) AUS JOONDALUP (8am-12am) 1-43 WINTON RD (08) (08) AUS KALGOORLIE (8am-12am) 172 BOULDER RD (08) (08) AUS KARRATHA (8am-12am) LOT 1415 CRANE CIR (08) (08) L&H KELMSCOTT (8am-12am) UNIT 1/17 GILLAM DR (08) (08) L&H KENWICK (8am-12am) 24 AUSTIN AVE (08) (08) L&H KUNUNURRA 39 BANDICOOT DR (08) (08) L&H MALAGA (8am-12am) UNIT 1/1890 BEACH RD (08) (08) L&H MANDURAH (8am-11am) LOT 6/63 RESERVE DR (08) (08) L&H MIDLAND (8am-12am) 37 FARRALL RD (08) (08) L&H * MYAREE (8am-12am) 80 MCCOY ST (08) (08) L&H * OSBORNE PARK (8am-12am) 41 GUTHRIE ST (08) (08) AUS PORT HEDLAND LOT 1421 HARDIES ST (08) (08) L&H ROCKINGHAM (8am-12am) UNIT 2/2 PICKARD AVE (08) (08) L&H WANNEROO 9 BENEFICIAL WAY (08) (08) AUS* WELSHPOOL 27A COLIN JAMIESON DR (08) (08) L&H Lawrence & Hanson AUS Auslec Branch open Saturday (trading hours) * Data & Comms specialist branch Industrial Outlet Scan for store locator & map

116

Corporate Profile ROYAL. MODERN ROYAL ELECTRIC Ideal Power Solution MRE ELECTRICAL, INSTRUMENTATION & COMMUNICATION SYSTEMS

Corporate Profile ROYAL. MODERN ROYAL ELECTRIC Ideal Power Solution MRE ELECTRICAL, INSTRUMENTATION & COMMUNICATION SYSTEMS Corporate Profile MODERN ROYAL ELECTRIC Ideal Power Solution ROYAL MRE ELECTRICAL, INSTRUMENTATION & COMMUNICATION SYSTEMS MAJOR STOCKIST >>> CATHODIC PROTECTION CABLES >>> LOW VOLTAGE CABLES >>> MEDIUM

More information

FIRE RESISTANT CABLE CONSTRUCTION OF CABLES

FIRE RESISTANT CABLE CONSTRUCTION OF CABLES FIRE RESISTANT CABLE In all fire disasters, fire smoke, heat and toxic fumes are the main obstacles to safe evacuation of a building or area. A major contribution towards overcoming these hazards is the

More information

ScottishPower Distribution Cables & Equipment. Metal Theft

ScottishPower Distribution Cables & Equipment. Metal Theft ScottishPower Distribution Cables & Equipment Metal Theft April 2012 As an aid to deterring to metal theft this booklet has been put together to help identify the types of utility power cables and associated

More information

BETAtrans. Cables and Systems for Rolling Stock. Edition 2006

BETAtrans. Cables and Systems for Rolling Stock. Edition 2006 BETAtrans Cables and Systems for Rolling Stock. Edition 2006 Info Consulting and Sales By Phone To ask for Information or to place an order please use the following number: +49 (0)9172-6844-11 By Fax For

More information

The Quality Connection. BETAflam Fire Resistant Safety Cables

The Quality Connection. BETAflam Fire Resistant Safety Cables The Quality Connection BETAflam Fire Resistant Safety Cables 2 Contact Consulting and sales Switzerland Phone +41 (0)62 288 82 82 Fax +41 (0)62 288 83 83 [email protected] www.leoni-infrastructure-datacom.com

More information

3.6/6 kv XLPE insulated cables 5. 6/10 kv XLPE insulated cables 15. 8.7/15 kv XLPE insulated cables 25. 12/20 kv XLPE insulated cables 35

3.6/6 kv XLPE insulated cables 5. 6/10 kv XLPE insulated cables 15. 8.7/15 kv XLPE insulated cables 25. 12/20 kv XLPE insulated cables 35 CONTENTS INTRODUCTION 1 Cable selection, cable specification, cable services CABLES Constructional data: 3.6/6 kv XLPE insulated cables 5 SECTION 1 6/10 kv XLPE insulated cables 15 SECTION 2 8.7/15 kv

More information

CONFLEX ELECTRIC CABLE

CONFLEX ELECTRIC CABLE CONFLEX ELECTRIC CABLE CONFLEX - 0.6/1kV Flexible VSD/EMC Cables Applications WW VSD/EMC cables are manufactured for use where electrical interference distorts signal transmission in electric motors. Standard

More information

CLEVELAND CABLE LOCATIONS

CLEVELAND CABLE LOCATIONS A WORLD POWER IN CABLE SUPPLY THE CABLE AND ACCESSORY CATALOGUE 2011 2 CLEVELAND CABLE LOCATIONS CLEVELAND CABLE LOCATIONS 3 As is illustrated within our catalogue, we stock a comprehensive range of cables

More information

www.ptranscable.com We specialize in low voltage cables including: Stranded Single Cable H07V-R Flexible Single Cable H05V-K

www.ptranscable.com We specialize in low voltage cables including: Stranded Single Cable H07V-R Flexible Single Cable H05V-K P-trans, meaning power transistor, is a well known cable manufacturer based in Aan - Jordan. The production plant produces all sorts of high quality low tension cables and is a leader in the industry supplying

More information

Chemical resistance Accidental

Chemical resistance Accidental Industrial flexible cable, insulation and outer sheath in elastomer Description Application TITANEX flexible cable is intended for installations with moving equipment, electric appliances and for building

More information

Specializing in the cable business for over 38 years, PT. SUPREME CABLE

Specializing in the cable business for over 38 years, PT. SUPREME CABLE Specializing in the cable business for over 38 years, PT. SUPREME CABLE MANUFACTURING & COMMERCE Tbk. (PT. SUCACO Tbk) has grown steadly to become a largest and leading cable manufacturer, with international

More information

The Handbook 2013 EDITION

The Handbook 2013 EDITION The Handbook 2013 EDITION Trust Als you safe Alsecure is the cable you can stake your reputation on when safety and security are critical to maintain circuit integrity for mains power, lighting, alarms,

More information

Gulf Cable & Electrical Ind. Co.

Gulf Cable & Electrical Ind. Co. CONTENTS INTRODUCTION PRODUCT RANGE I PRODUCT DATA TABLES Irrigation 1 Coaxial s for T.V/ Satellite Antenna etc 2 Data Transmission s - 4 pair 24 AWG 3 TELEPHONE CABLES Telephone cables CCP-LAP & CCP-LAP-SS

More information

Flexible cables for submersible products

Flexible cables for submersible products Flexible cables for submersible products Standards SUBCAB cables complies with the following general standards: IEC 6045 (general) IEC 608 class 5 (conductor) IEC 608-- CLAUSE 9 (oil resistant) IEC 608--

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60502-1 Second edition 2004-04 Power cables with extruded insulation and their accessories for rated voltages from 1 kv (U m = 1,2 kv) up to 30 kv (U m = 36 kv) Part 1: Cables

More information

Fault location on power cables. Fault location on power cables

Fault location on power cables. Fault location on power cables Fault location on power cables Fault location on power cables Contents: 1. Introduction 2. Construction of power cables 3. Cable faults 01. Introduction Fault location on communication and power cables

More information

AFUMEX LSX LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 BASEC APPROVED PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:

AFUMEX LSX LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 BASEC APPROVED PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS: PRODUCT DATASHEET & APPLICATIONS GUIDE BASEC APPROVED AFUMEX LSX LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 KEY BENEFITS: BASEC approved for the full size range of BS8436 (1.0mm 2 to 2.5mm 2

More information

VIPERFLEX ELECTRIC CABLE

VIPERFLEX ELECTRIC CABLE VIPERFLEX Flexible Low Voltage Electric Cable - 0.6/1kV (Rubber insulated) H07 RN-F & H07 BN-F Single Core 2-Core 2-Core and Earth 3-Core and Earth 4-Core and Earth Multi-Core and Earth H07 RCN-F & H07

More information

Flygt flexible cables

Flygt flexible cables Flygt flexible cables Contents Standards General SUBCAB 4 Screened SUBCAB 6 Rubber cable type: NSSHÖU-J 7 Screened rubber cable type: NSSHÖU../E + ST 8 FGB screened rubber cable 9 PUR control cable 0 HCR

More information

I N D U S T R I A L C A B L E G L A N D S

I N D U S T R I A L C A B L E G L A N D S Introduction 1/2 Industrial Cable Gland W Industrial Cable Gland WL Heavy Duty Industrial Cable Gland CW Industrial Cable Gland CZ Industrial Cable Gland 1W Industrial Cable Gland 1Z Industrial Cable Gland

More information

Technical cable guide

Technical cable guide Technical cable guide November 2014 One stop-shop for all your cable needs Welcome to the latest edition of the Technical Cable Guide. Following the recent acquisition of Draka, the Prysmian Group is now

More information

Electrical Safety Products

Electrical Safety Products Electrical Safety Products Trelleborg Electrical Safety Products A safe working environment is important in all industries, but in the electrical generation and supply industry, it is paramount. Trelleborg

More information

David O Brien, CMP Products ([email protected])

David O Brien, CMP Products (David.OBrien@cmp-products.com) David O Brien, CMP Products ([email protected]) 1) Main Function of Cable Glands 2) Common Issues with Cable Glands 3) Compliance / Standards, changing times 4) How do we select Cable Glands?

More information

Network Standard Advice No. 1420C 9/6/2011

Network Standard Advice No. 1420C 9/6/2011 Network Standard Advice No. 1420C 9/6/2011 TO: Customers, Service Providers and Ausgrid Staff. Advisory Note on Changes to the Use of 11kV Cable Types. Introduction This Network Standard Advice (NSA) provides

More information

Fire Resistant Cables

Fire Resistant Cables 109/4 Fire Resistant Cables SR 114H Standard - SR 114E Enhanced BS 5839-1 BS 7629-1 BS 6387 BS 8434-1/2 BS 6425 BS 7622 EN 50200 World-wide recognized high quality cables Firecel SR114 are used in: Data

More information

FIRE RESISTANT CABLES FP200 GOLD

FIRE RESISTANT CABLES FP200 GOLD FIRE RESISTANT CABLES FP200 GOLD FIRE RESISTANT CABLES FP200 GOLD BS7629-1:2008 Certificate No 077f Certificate No 077k FP200 GOLD The original highly durable and dressable, easy to terminate and install

More information

Flexible and safe solutions, for decades. Cables for alarmand safety systems

Flexible and safe solutions, for decades. Cables for alarmand safety systems Flexible and safe solutions, for decades. Cables for alarmand safety systems 2 We offer the widest range of cables on the market for every kind of installation. It s all about reliability. It is always

More information

Flexible Control Cables

Flexible Control Cables Works photo: KUKA Flexible Control Cables A Flexible Control Cables Since generations people try to build machines and plants which shall take on different functions. To raise, sink, slide, drill, transport

More information

HOW TO CORRECTLY CONNECT DEEP CYCLE BATTERIES AND CHOOSE THE RIGHT CABLE SIZING

HOW TO CORRECTLY CONNECT DEEP CYCLE BATTERIES AND CHOOSE THE RIGHT CABLE SIZING HOW TO CORRECTLY CONNECT DEEP CYCLE BATTERIES AND CHOOSE THE RIGHT CABLE SIZING There are several ways to wire multiple batteries to achieve the correct battery voltage or capacity for a particular DC

More information

Power and Wiring Cables

Power and Wiring Cables 1 Single-Core PVC 1X...................... 1: Single-Core PVC/PVC 1Y.................. 1: Flat Twin & Flat Three Core PVC /Y........ 1: Multicore XLPE/LSF/SWA/LSF BS Control Cable.............................

More information

Unarmored Variable Frequency Drive (VFD) Cable Termination Guide

Unarmored Variable Frequency Drive (VFD) Cable Termination Guide Authorized Distributor Unarmored Variable Frequency Drive (VFD) Cable Termination Guide Be Certain with Belden A Step-by-Step Look at the Connection/Termination of Unarmored VFD Cables Terminating Unarmored

More information

The Quality Connection. LEONI Industrial Solutions Custom-Made Cables

The Quality Connection. LEONI Industrial Solutions Custom-Made Cables The Quality Connection LEONI Industrial Solutions Custom-Made Cables 2 www.leoni-industrial-solutions.com The LEONI Group is one of the world s largest suppliers of wires, cables and wiring systems, with

More information

Cables, Cable Laying & Accessories Manual

Cables, Cable Laying & Accessories Manual Distribution Business Cables, Cable Laying & Accessories Manual Database ref: File Ref: Title Page & Revision Log For Cables & Access v4 - Nov 2003.doc Manual Name: Cables & Accessories Manual Version

More information

Global cable expertise for rolling stock

Global cable expertise for rolling stock Global cable expertise for rolling stock Global cable expertise for rolling stock Single and multicore Low voltage control cables Jumper cables HV roof cables (25 kv) rubber cables for power needs of locomotives

More information

with coloured cores and overall copper screen UL/CSA... 17

with coloured cores and overall copper screen UL/CSA... 17 CONTENT Cable Track Cables y SD 200 extremely flexible TPE/PUR data cable with coloured cores for continuous movement..... 6 y S 200 extremely flexible TPE/PUR control cable with numbered cores for continuous

More information

e-mobility Special cables for electric vehicles Coroplast Fritz Müller GmbH & Co. KG Tapes Cables Cable Assemblies

e-mobility Special cables for electric vehicles Coroplast Fritz Müller GmbH & Co. KG Tapes Cables Cable Assemblies www.echtzeit.com e-mobility Coroplast Fritz Müller GmbH & Co. KG Tapes Cables Cable Assemblies Special cables for electric vehicles Wittener Straße 271 D-42279 Wuppertal Phone +49(0)202.2681.228 Fax +49(0)202.2681.360

More information

KNOW YOUR OPTIONS: 230 KV POWER CABLES

KNOW YOUR OPTIONS: 230 KV POWER CABLES KNOW YOUR OPTIONS: 230 KV POWER CABLES 71 CONDUCTOR MATERIAL AND SIZE Conductor material is a matter of both customer preference and required current carrying capacity At 230 kv, copper is most common

More information

5.2. Overview. The better method to install solderless compression connectors on power cable

5.2. Overview. The better method to install solderless compression connectors on power cable 5.2 Overview The better method to install solderless compression connectors on power cable The Thomas & Betts method of installing compression connectors on power cables is designed to provide a high degree

More information

TECHNICAL SPECIFICATION FOR HIGH TENSION LINE HARDWARE AND ACCESSORIES FOR ACSR PANTHER & WOLF CONDUCTOR

TECHNICAL SPECIFICATION FOR HIGH TENSION LINE HARDWARE AND ACCESSORIES FOR ACSR PANTHER & WOLF CONDUCTOR TECHNICAL SPECIFICATION FOR HIGH TENSION LINE HARDWARE AND ACCESSORIES FOR ACSR PANTHER & WOLF CONDUCTOR 1.1.0 SCOPE : This specification covers design, manufacture, testing at manufacture s works before

More information

Gulf Cable & Electrical Ind. Co.

Gulf Cable & Electrical Ind. Co. CONTENTS INTRODUCTION PRODUCT RANGE I PRODUCT DATA TABLES XLPE INSULATED 600/1000V CABLES Two Core Cables CU/XLPE/PVC/LC/PVC/SWA/PVC 1 Three Core Cables CU/XLPE/PVC/LC/PVC/SWA/PVC 2 Four Core Cables CU/XLPE/PVC/LC/PVC/SWA/PVC

More information

Trial Exams C. Standards and Regulations. Examination No: GH-08-C- 1 hour and 5 minutes plus 10 minutes reading time

Trial Exams C. Standards and Regulations. Examination No: GH-08-C- 1 hour and 5 minutes plus 10 minutes reading time Trial Exams C Standards and Regulations Examination No: GH-08-C- This test is intended to gauge your knowledge of essential information contained within AS/CA S009:2013. To qualify for an allpication to

More information

The Quality Connection. High Performance Cable Solutions for the World of Semiconductors

The Quality Connection. High Performance Cable Solutions for the World of Semiconductors The Quality Connection High Performance Cable Solutions for the World of Semiconductors 2 Total Flexibility for Applications with the Toughest Requirements LEONI is your long-term, reliable partner supplying

More information

The Quality Connection. High Performance Cable Solutions for the World of Semiconductors

The Quality Connection. High Performance Cable Solutions for the World of Semiconductors The Quality Connection High Performance Cable Solutions for the World of Semiconductors 2 Total Flexibility for Applications with the Toughest Requirements LEONI is your long-term, reliable partner supplying

More information

Control cables CF880 PVC 12,5-5/ +70 3 20 2 CF881 PVC 12,5-5/ +70 3 20 4. CF890 igupur 12,5-20/ +80 3 20 6. CF891 igupur 12,5-20/ +80 3 20 8

Control cables CF880 PVC 12,5-5/ +70 3 20 2 CF881 PVC 12,5-5/ +70 3 20 4. CF890 igupur 12,5-20/ +80 3 20 6. CF891 igupur 12,5-20/ +80 3 20 8 ables......chainflex M...11.2013...plastics for longer life....eu 1million hainflexm...cost-efficient cable program for machine tools... The new igus chainflex M cables chainflex M type Rainer Rössel Head

More information

6 ELECTRICAL PARAMETERS

6 ELECTRICAL PARAMETERS 6 ELECTRICAL PARAMETERS For power, low voltage and medium voltage cables, cross section nominal areas are calculated in taking into account several parameters as: permissible current carrying capacities

More information

Section 5 161 kv Power Cables

Section 5 161 kv Power Cables Know Your Options: 161 kv Power Cable 61 material and size material is a matter of both customer preference and required current carrying capacity Copper conductor common for larger loads When both copper

More information

Speciality Cabling Solutions

Speciality Cabling Solutions Speciality Cabling Solutions About Brand-Rex Brand-Rex Limited was established in the UK in 1972, whilst the company s roots stretch back to 1942 in the United States when the original Brand Corp and Rex

More information

Cutting and stripping tools

Cutting and stripping tools Cutting and stripping tools Introduction 2 Cutting and stripping tool 0.02-10 mm² (16 mm²) 3 Stripping tool for cables Ø 2.5-40 mm 4 Tools for cutting and stripping of conductors 0.5-6 mm² and for cutting

More information

RADOX railway cables acc. to EN 50264 and EN 50306. Edition 2009

RADOX railway cables acc. to EN 50264 and EN 50306. Edition 2009 RADO railway cables acc. to EN 50264 and EN 50306 Edition 2009 Bridging our know how Interdisciplinary knowledge The HUBER+SUHNER Group is a leading international manufacturer of electrical and optical

More information

International Electrotechnical Commission Standards

International Electrotechnical Commission Standards International Electrotechnical Commission Standards Standard IEC 60028 IEC 60038 IEC 60050-461 IEC 60055-1 IEC 60055-2 IEC 60092-101 IEC 60092-350 IEC 60092-351 IEC 60092-352 IEC 60092-353 IEC 60092-354

More information

Connect. Cable preparation and cutting tools

Connect. Cable preparation and cutting tools Connect Cable preparation and cutting tools 390 Our range of cable preparation tools includes hand-operated & ratchet action cable cutting tools, wire preparation & stripping tools and SWA & hydraulic

More information

KNOW YOUR OPTIONS: 69 KV XLPE POWER CABLE

KNOW YOUR OPTIONS: 69 KV XLPE POWER CABLE Know Your Options: 69 kv XLPE Power Cable 3 material and size material is a matter of both customer preference and required current carrying capacity Copper conductor common for larger loads When both

More information

Cabling & Connectivity

Cabling & Connectivity Cabling & Connectivity Communication, Mining + Industrial, Security + Integration, Transport www.madisontech.com.au We get you. TM Madison Cabling & Connectivity We manufacture and distribute a wide range

More information

EcoFlex Cable. Smaller. Lighter. Tougher. 100% Recyclable.

EcoFlex Cable. Smaller. Lighter. Tougher. 100% Recyclable. EcoFlex Cable Smaller. Lighter. Tougher. 100% Recyclable. Total Performance, Completely Recyclable EcoFlex cable is Alpha Wire s newest innovation in control cabling. A true engineering breakthrough, EcoFlex

More information

Presenters Brett Weiss, Gabe Martinez, Brian Kroeger.

Presenters Brett Weiss, Gabe Martinez, Brian Kroeger. 1 Presenters Brett Weiss, Gabe Martinez, Brian Kroeger. Topics to be covered: Cable identification Purpose of the various cable types Installation techniques Building Infrastructure Overview of networking

More information

Standard Buccaneer - Ethernet

Standard Buccaneer - Ethernet IP6 rated compliant PUR jacket on cable Shielded system shielded coupler Shroud on RJ45 Screw coupling Rewireable flex connector PCB mounted panel connector IDC termination panel connector Earth lead version

More information

No Heat. No Flames. No Shoving. No Special Tools. 3M Cold Shrink. 3M Cold Shrink. Medium Voltage Joints & Terminations. 3M Cold Shrink Joint

No Heat. No Flames. No Shoving. No Special Tools. 3M Cold Shrink. 3M Cold Shrink. Medium Voltage Joints & Terminations. 3M Cold Shrink Joint M Cold Shrink Medium Voltage Joints & Terminations M Cold Shrink Joint Splice bodies 00% factory tested - ensures reliability Capacitive Stress Relief No Heat No Flames No Special Tools No Shoving Unique

More information

Offshore Transformer Platform. Technical Standard. Energinet.dk. HV, MV, LV and Signal Cables and Cable Routing

Offshore Transformer Platform. Technical Standard. Energinet.dk. HV, MV, LV and Signal Cables and Cable Routing Offshore Transformer Platform Technical Standard Energinet.dk HV, MV, LV and Signal Cables and Cable Routing ETS - 03 Rev. 1 Acadre doc. 44858-09 Revision survey Chpt. Description Revision Date Resp. -

More information

Marine & Shipboard Cable JIS C 3410(1999) IEC 60092-350, 353, 354, 376

Marine & Shipboard Cable JIS C 3410(1999) IEC 60092-350, 353, 354, 376 T o t a l S o l u t i o n o f M a r i n e C a b l e Marine & Shipboard Cable JIS C 3410(1999) IEC 60092-350, 353, 354, 376 Marine & Shipboard cable Total Solution of Marine Cable JIS C 3410(1999), IEC

More information

Supplementary instructions. Connection cable IP 66/IP 68 (1 bar) Retrofitting set/accessory for instruments of the plics family. Document ID: 34107

Supplementary instructions. Connection cable IP 66/IP 68 (1 bar) Retrofitting set/accessory for instruments of the plics family. Document ID: 34107 Supplementary instructions Connection cable IP 66/IP 68 (1 bar) Retrofitting set/accessory for instruments of the plics family Document ID: 4107 Contents Contents 1 For your safety 1.1 Appropriate use...

More information

Airdac CNE and SNE, 600/1000V, Polyethylene Sheath, SANS 1507, NRS 063 & NRS 017

Airdac CNE and SNE, 600/1000V, Polyethylene Sheath, SANS 1507, NRS 063 & NRS 017 Airdac CNE and SNE, 600/1000V, Polyethylene Sheath, SANS 1507, NRS 063 & NRS 017 Conductor: Hard Drawn Copper Conductor Class 2 Insulation: LV-XLPE Phase Color Code(SNE): Red, Black & Bare Copper Phase

More information

SCHEDULE ' A' TECHNICAL SPECIFICATION FOR 11/22/33KV H.T.XLPE POWER CABLE FOR DISTRIBUTION NETWORK IN MAHARASHTRA (SPECIFICATION NO.

SCHEDULE ' A' TECHNICAL SPECIFICATION FOR 11/22/33KV H.T.XLPE POWER CABLE FOR DISTRIBUTION NETWORK IN MAHARASHTRA (SPECIFICATION NO. SCHEDULE ' A' TECHNICAL SPECIFICATION FOR 11/22/33KV H.T.XLPE POWER CABLE FOR DISTRIBUTION NETWORK IN MAHARASHTRA (SPECIFICATION NO.MM/I/HTXLPE/2006) MAHARASHTRA STATE ELECTRICITY DISTRIBUTION CO.LTD.

More information

MICROCABLES. A complete vision of your connectivity needs. Catalogue

MICROCABLES. A complete vision of your connectivity needs. Catalogue MICROCABLES A complete vision of your connectivity needs Catalogue ELECTRONIC Filotex Introduction Application Nexans s line of microcables is designed towards the increasing requirements of electronics

More information

ENERGY. TECWATER S1BN8-F 0,6/1 kv. Cable for Water Application

ENERGY. TECWATER S1BN8-F 0,6/1 kv. Cable for Water Application ENERGY TECWATER S1BN8-F 0,6/1 kv Cable for Water Application Technical Data Electrical parameters Thermal parameters Trademark Type designation Specification Approval Application Rated voltage Maximum

More information

CMP PRODUCTS CMP. Terminating Cables is our Business. Onshore Offshore Marine Mining Surface Underground

CMP PRODUCTS CMP. Terminating Cables is our Business. Onshore Offshore Marine Mining Surface Underground PRODUCTS Industrial and Explosive Atmosphere s and Conduit Accessories Terminating s is our Business Onshore Offshore Marine Mining Surface Underground Solutions complying with BS 6121, EN 50262, IEC 62444,

More information

<< Previous Page Next Page >>

<< Previous Page Next Page >> > CONTENTS INTRODUCTION 01 INDUSTRIAL CABLE GLANDS 03-09 COMPRESSION TERMINALS 10-22 CABLE CLEATING & FIXING SYSTEMS 23-33 STANDARD SELECTOR CHARTS 34-37

More information

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155 DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155 Technical information Version: 07.14 General Function The speed sensors family DSD.70 are suitable for generating

More information

HIGH- AND EXTRA-HIGH-VOLTAGE GLOBAL CABLE SYSTEM SOLUTIONS Rely On Our Experience... Experience Our Capabilities

HIGH- AND EXTRA-HIGH-VOLTAGE GLOBAL CABLE SYSTEM SOLUTIONS Rely On Our Experience... Experience Our Capabilities HIGH- AND EXTRA-HIGH-VOLTAGE GLOBAL CABLE SYSTEM SOLUTIONS Rely On Our Experience... Experience Our Capabilities RELY ON OUR EXPERIENCE... EXPERIENCE OUR CAPABILITIES For close to half a century, Silec

More information

PROFIBUS cable. PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications

PROFIBUS cable. PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications Data Sheet 10/63-6.47-EN Rev. D PROFIBUS cable PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications PROFIBUS PA cables Non-Ex (Hazardous) applications Ex (Hazardous) applications

More information

HINDUSTAN PETROLEUM CORPORATION LIMITED ENGINEERING & PROJECTS GRESHAM ASSURANCE HOUSE, 2 ND FLOOR, A-1595(3) 1-A, SIR P M ROAD, FORT MUMBAI-400 001

HINDUSTAN PETROLEUM CORPORATION LIMITED ENGINEERING & PROJECTS GRESHAM ASSURANCE HOUSE, 2 ND FLOOR, A-1595(3) 1-A, SIR P M ROAD, FORT MUMBAI-400 001 NEW POL DEPOT AT HINDUSTAN PETROLEUM CORPORATION LIMITED ENGINEERING & S GRESHAM ASSURANCE HOUSE, 2 ND FLOOR, A-1595(3) 1-A, SIR P M ROAD, FORT MUMBAI-400 001 TECHNICAL SPECIFICATION OF XLPE, FRLS LT CABLES

More information

LEAD FREE FIREX. Interlock Armored Cables TECK90 and MC Industrial Cables. w w w. n e x a n s e n e r g y. c o m

LEAD FREE FIREX. Interlock Armored Cables TECK90 and MC Industrial Cables. w w w. n e x a n s e n e r g y. c o m FIREX Interlock Armored Cables TECK90 and MC Industrial Cables LEAD FREE O V E R 1 8 0 Y E A R S O F E X P E R I E N C E 866-663-9267 w w w. n e x a n s e n e r g y. c o m Interlock Armored Cables Introduction....2

More information

Connecting your business

Connecting your business mobiles Connecting your business fixed voice & data digital & IT autovoice managed services adsi energy About us Founded in 2002, ADSI are dedicated to reducing business costs by offering high-quality

More information

Bespoke, Own Label Lifejackets

Bespoke, Own Label Lifejackets Bespoke, Own Label Lifejackets SUPERYACHT SPARES Specify your own lifejacket to suit your market needs: Choosing from: A wide range of cover options in design, fabric or colour 5 Different Bladder styles

More information

CABLE ACCESSORIES 110-220 kv

CABLE ACCESSORIES 110-220 kv CABLE ACCESSORIES 110-220 kv Termination 110 kv Technical description Termination MKB 126 / 145 with composite type insulator uses for cable line joints with other elements of power-supply systems. Termination

More information

PROFIBUS cable. for PROFIBUS-PA and -DP 10/63-6.46 EN

PROFIBUS cable. for PROFIBUS-PA and -DP 10/63-6.46 EN for PROFIBUS-PA and -DP 10/63-6.46 EN CPN 080/CPE 080-Ex PROFIBUS-PA basis cable AWG 18, 0.88 mm 2 Use For fixed installation indoor and outdoor, on racks and in conduits. Application Fieldbus cable for

More information

COAX Cables Radio Frequency Cables

COAX Cables Radio Frequency Cables COAX Cables Radio Frequency Cables Contents Page Table of contents Pictographs General information Introduction Types and abbreviations Temparature range Construction Characteristics Special constructions

More information

Coaxial Cables for Medium-Frequency Applications

Coaxial Cables for Medium-Frequency Applications Coaxial Cables for Medium-Frequency Applications Coaxial Cables for Medium-Frequency Applications Introduction Telecommunications technology is moving forward rapidly and the need for fast and reliable

More information

ALARMLINE ANALOGUE Linear Heat Detection System

ALARMLINE ANALOGUE Linear Heat Detection System ALARMLINE ANALOGUE Alarmline Analogue sensor cable senses temperature variations by continuously monitoring the resistance of specially doped N.T.C. polymeric insulation. A change in temperature produces

More information

GUIDE TO THE AM2 EXAM

GUIDE TO THE AM2 EXAM AM2 GUIDE TO THE AM2 EXAM What is AM2? AM2 or the Achievement Measurement 2 is a practical performance skill test administered by the National Electrotechnical Training (NET). You must take the AM2 test

More information

Fibre optic cables MDIC LSZH

Fibre optic cables MDIC LSZH MDIC LSZH MDIC LSZH - Indoor Access Cable. Micro Drop Installation Cable, special Access cable with low bend radius, no waterpeak G.657.A fibres. Ruggedized construction with excellent performance, easy

More information

UGVCL/SP/591/11KV HT AB CABLE

UGVCL/SP/591/11KV HT AB CABLE TECHNICAL SPECIFICATION FOR 11KV AERIAL BUNCHED CABLES FOR OVERHEAD LINES (CROSSED LINKED POLYTHENE DRY GAS CURED) 1. SCOPE This specification covers requirements of XLPE insulated, 11 KV Aerial Bunched

More information

Draka Industrial Cable GmbH

Draka Industrial Cable GmbH A) Preparation of cable ends To enable the stranding of the cores after connecting main and earth cores, each of the cable ends to be connected are laid in a double loop with righthand turn and then fixed

More information

Caledonian Submersible Pump Cables for Oil Industry >> IEEE 1018 >> IEEE 1019 >> API RP 11S5

Caledonian Submersible Pump Cables for Oil Industry >> IEEE 1018 >> IEEE 1019 >> API RP 11S5 Caledonian Submersible Pump Cables for Oil Industry >> IEEE 1018 >> IEEE 1019 >> API RP 11S5 Caledonian Windmill Cables COMPANY PROFILE Table of Content Caledonian, established in 1978, offers one of the

More information

800 Communications Circuits

800 Communications Circuits ARTICLE 800 Communications Circuits INTRODUCTION TO ARTICLE 800 COMMUNICATIONS CIRCUITS This article has its roots in telephone technology. Consequently, it addresses telephone and related systems that

More information

Trade of Electrician. Three-phase Distribution Boards And Socket Circuits

Trade of Electrician. Three-phase Distribution Boards And Socket Circuits Trade of Electrician Standards Based Apprenticeship Three-phase Distribution Boards And Socket Circuits Phase 2 Module No. 2.3 Unit No. 2.3.2 COURSE NOTES Created by Charlie Walsh - Athlone TC Revision

More information

EDS 02-0027 11KV TRIPLEX CABLE

EDS 02-0027 11KV TRIPLEX CABLE THIS IS AN UNCONTROLLED DOCUMENT, THE READER MUST CONFIRM ITS VALIDITY BEFORE USE Document Number: EDS 02-0027 ENGINEERING DESIGN STANDARD EDS 02-0027 11KV TRIPLEX CABLE Network(s): EPN, LPN, SPN Summary:

More information

APPLICATION ORIENTED DESIGN OF CABLES

APPLICATION ORIENTED DESIGN OF CABLES APPLICATION ORIENTED DESIGN OF CABLES Mrs. Rohini Bhattacharyya, Dubai cables Ltd.P. O. Box 11529,Dubai. [email protected] Mr. Nawaf Ahmad Al Mohaideb Dubai Cables Ltd. P. O. Box 11529, Dubai. [email protected]

More information

NORTH ORANGE COUNTY COMMUNITY COLLEGE DISTRICT SECTION 27 05 26 GROUNDING AND BONDING FOR COMMUNICATION SYSTEMS

NORTH ORANGE COUNTY COMMUNITY COLLEGE DISTRICT SECTION 27 05 26 GROUNDING AND BONDING FOR COMMUNICATION SYSTEMS SECTION GROUNDING AND BONDING FOR COMMUNICATION SYSTEMS RELATED SECTIONS: Section 27 00 00 General Requirements Section 27 02 00 Communication General Requirements Section 27 05 28 Pathways for Communications

More information

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK Pressure monitoring equipment for oil-sf 6 bushings, type GOEK Installation and maintenance guide 5693 827-6 en, Rev. 3, 2002-01-30 This document must not be copied without our written permission, and

More information

CABLES FOR PHOTOVOLTAIC SOLAR ENERGY INSTALLATIONS FOR CLEAN ENERGY

CABLES FOR PHOTOVOLTAIC SOLAR ENERGY INSTALLATIONS FOR CLEAN ENERGY CABLES FOR PHOTOVOLTAIC SOLAR ENERGY INSTALLATIONS FOR CLEAN ENERGY One Company Connecting The World POWERFUL PRESENCE PRODUCTS PERFORMANCE PEOPLE General Cable has been a wire and cable innovator for

More information

Operating Instructions

Operating Instructions Operating Instructions Cable Glands Ex d and Ex e with Compound > Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Safety Information...3 4 Designated Use...4 5 Technical Data...4

More information

Linking sustainable ideas to real-world results

Linking sustainable ideas to real-world results Linking sustainable ideas to real-world results Prysmian Group, members of: Prysmian Group 700 Industrial Drive, Lexington, SC 29072 Tel: 1-800-845-8507 www.prysmianusa.com 137 Commerce Drive R.R. #3 Prescott,

More information

Specifying an IT Cabling System

Specifying an IT Cabling System Specifying an IT Cabling System This guide will help you produce a specification for an IT cabling system that meets your organisation s needs and gives you value for money. You will be able to give your

More information

Amphenol Cable Glands and Cord Grips 12-055-1. Amphenol

Amphenol Cable Glands and Cord Grips 12-055-1. Amphenol Amphenol Cable Glands and Cord Grips 12-055-1 Amphenol Table of Contents Page Number Introduction 1 Amphenol Cable Glands 2-3 ATEX Approved Glands Featuring Elastometric Seals EX-20 4-5 EX-25 6-7 EE-30

More information

MEDIUM VOLTAGE CABLES Up to and including 36 KV

MEDIUM VOLTAGE CABLES Up to and including 36 KV MEDIUM VOLTAGE CABLES Up to and including 6 KV NOTICE As this catalogue is not intendedto cover all of LIBAN CABLES SAL possibilities in special cables manufacturing, the hereafter listing of the types

More information

Cables and Accessories Selection Guide

Cables and Accessories Selection Guide Cables and Accessories Selection Guide From data centers to robotics to patient monitoring equipment, we re committed to enabling the next generation of faster, smaller and smarter design. 3M offers an

More information

Top Drive Service Loops. Conventional, Enhanced and Superior Solutions for Drilling Applications

Top Drive Service Loops. Conventional, Enhanced and Superior Solutions for Drilling Applications Top Drive Service Loops Conventional, Enhanced and Superior Solutions for Drilling Applications Linking the future As the worldwide leader in the cable industry, Prysmian Group believes in the effective,

More information

Cable flexibility Flexible. Chemical resistance Accidental

Cable flexibility Flexible. Chemical resistance Accidental H07RN-F Industrial flexible cable, insulation and outer sheath in elastomer Description pplication H07RN-F flexible cable is intended for installations with moving equipment, electric appliances and for

More information