T A B L E T 1 T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A
|
|
- Joshua Washington
- 8 years ago
- Views:
Transcription
1 T A B L E T 1 1 of 7 Tests & Inspection Cable PCUT & PCUT-A (Table T1) T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A No. Test Scale MOC Requirements G 20:10:001:01 Defined Test Clause Ref. Method Other Refs a. Tests On Completed Cable Lengths (Manufacturer-100 %) MOC Inspector 10 % Of Drums Of Each Type And Size Of Cable Selection At Random Conductor Resistance at 20 C Resistance Unbalanced at 20 C Conductor Diameter Mutual Conductance 5 Mutual Capacitance 6 7 Capacitance Unbalance Insulation Resistance 5 % of Pairs in each 5 % of Pairs in each 5 % of Pairs in each Conductance Ω/Km max: Max. 2 % of loop resistance 1 pair of each 2 Micro MΩ/Km 10 % pairs of each 10 % pairs of each layer 5 % of conductance in each 8 Dielectric Strength All tested drums 9 Gas Pressure Test All tested drums Cable Over all Diameter Identification and Length marker on Sheath Cable End Treatment 13 Cable Drum IEC 28 IEC 344 DC Bridge IEC Clause 24 Clause 15.2 Clause to 0.9 mm Direct Measurement Clause 5.2 Max. Av. 55 nf/km Ind. Max. 58 nf/km Per 160 m Length Mean 100 pf Max. 250 pf 10,000 MΩ..Km at 20 C Minimum Between conductors 500 V AC for 3 seconds All conductors and sheath 1500 V AC for 3 seconds Max. leakage 100 g/cm 2 after 12 hours MOC Requirement 1000 Hz at 20 C Clause 5.4 Clause 5.5 /5.3 A to B/A to earth, B to earth with 500 V DC up to 1 min. All other conductors and sheath earthed Clause 5.2 Al conductor bonded together Pressurised at 4 kg/cm² All tested drums See Cable Spec. Direct Measurement All tested drums All completed Drums All completed Drums Type, size, gauge at 1 meter intervals White lettering on sheath i. Valve at inner end ii. Cable banded in red at clockwise (outer) end. Green at inner (anticlockwise) end. iii. Pulling eye Fitted at outer end. 1. Pressure Maintenance at 650 g/cm Sign writing No., length, type, weight etc. Appearance Check Physical Check Pressure Measured and visual checks. Clause 15.7 Clause 15.4 Clause 15.5 Clause 15.6 Clause 15.8 Clause Table 10 for Clause 11 MOC Common Technical Requirements Clause 17.2 MOC Common Technical Requirements Clause And MOC Common Technical Requirements Clause 5.1.2
2 3. Length verification from sheath marking. And of 7
3 b. Tests During Manufacture (Random Sampling Tests) Conductor Elongation to Break Conductor Tensile Strength 4 tests for each type & size of cable 4 tests for each type & size of cable 16 Jointed Conductor Sample 17 Vacuum Indicator Test 18 Lead Sheath All Lengths All Length Sample 19 Identification Tape Each type of cable PE Jacket Tensile Strength 1) Normal 2) After Aging PE Jacket Elongation 1) Normal 2) After Aging Thickness of Insulating Paper Tensile Strength of Insulating Paper Lead Sheath Thickness 25 PE Jacket Thickness 26 Diameter of Finished Cable Core 27 Twinning and lay: 5 samples Dumbbell Test Pieces 5 samples Dumbbell Test Pieces Cond. Minimum % of length % of length % of length % of length Minimum 20kg/mm² 1) Tensile Strength Min.18 Kg/mm 2 2) Elongation 90 % of un-jointed conductor 3) Resistance 105 % of un-jointed similar length conductor Partial Vacuum Seamless with no joints or cracks Expandable by 50 % Manufacturer s name, type, size, gage at 150 mm intervals 1) Min. 1 Kg/mm 2 2) Max. change 20 % after heating for 48 hours at 100 C 3) Min. 400 % 4) Max. change 25 % after heating for 48 hours at 100 C 3 of 7 Clause 3.3 Length of specimen- 200 mm Jaw Speed ± 20 mm/min. Clause 3.3 ISO R402 1) 250 mm Length sample 2) 250 mm Length sample 3) 150 mm Length sample Measured 12 hours after sealing of cable ends immediately after sheathing Clause 16.1 Clause 16.1 Clause 6.6 Clause Clause 11.1 Clause Physical Check Clause 10 IEC 538 Clause 3 IEC 538 Clause 3 and ASTM D-412 Speed of Jaw separation mm/min Clause Clause Sample 0.04 mm Minimum Direct Measurement Clause 6.3 Sample Min. 1.8 Kg i.e Kg/µm thickness of paper 25 mm wide 0.25 mm thick test piece Each Cable Type See Specification Direct Measurement Sample of each cable type Sample of each cable type 27.1 Lay of Conductor 27.2 Colour marking & Arrangement of conductors See Specification See Specification Different for adjacent pairs. Max. 200 mm See Specification Visual Direct Measurement Direct Measurement Clause 16.2 Table 8 & 9 Table 10 Table 10 Measured Clause 7 Clause 6.5 Clause 6.7
4 28 Stranding: 28.1 Formation of Unit Rayon or Cotton Whipping of Layers 1 in Unit No. of Pairs in each 2 layer of Units Helical Paper tape Lapping of Units Number of Units on Lapping Tape Rayon or Cotton Whipping of Complete Units 6 Stranding of Layer in Units 28.2 Formation Of Cable: Whipping of Units in 1 Layers Number of Units in 2 Layers Core Wrapping Colour of Core 4 Wrapping 29 Cables Only: 29.1 Diameter of Steel armouring Wire 29.2 Lay of Steel Armouring Wire Thickness of Steel 29.3 Armouring Tape (If Applicable) Overlap of Steel Armouring tapes (If Applicable) Galvanised Coating on Steel Armouring Wire Thickness of Bedding Thickness of Serving Outer Minimum 3 Strands Visual Clause See Specification Visual Clause See Specification Visual Clause At intervals of Max. 50 mm Visual Clause See Specification Visual Clause Same Direction for All Layers Visual Clause See Specification Visual Clause See Specification Visual Clause Paper Wrappings 0.12 mm thickness 30 % overlap Lead Alloy-E Green Lead Alloy-B Red See Spec Range: 3 6 mm times θ Bedding mm See Spec. Visual Clause 9.1 Visual Clause 9.1 Measured Table-8 Measured Clause Measured Table % Measured Clause Min.: 200 g/m 2 ISO Table-5 See Spec. Measured Tables 8&10 See Spec. Measured Tables 8&10 30 Resistivity of Copper Sample Ω at 20 C IEC Lead Sheath Composition PE Compound Sp. Gravity Each Cable Type Alloy E or B Chemical Analysis Sample 33 PE Carbon Content Sample 34 PE Melt Flow Index Sample Max. 0.5 Medium Density Max ± 0.5 (By Weight) IEC-538 Clause 5.1 IEC-538 Clause 5 IEC-538 Appendix (B) Method-C Clause 6.3 Clause 9.3 Clause 10.2 Clause of 7
5 35 36 Brittle Temperature Failure Environmental Stress Crack Resistance 5 Specimens at 60 C 10 Specimens after 48 hours conditioning Nil Failure ASTM D-746 Nil Failure at conditioning temperature of 50 C Reagent Igepal CO-630 in 105 Aqueous solution ASTM D1693 See Note-1 on Preparation of Test specimens Note 1 5 of 7
6 E X P L A N A T O R Y N O T E Tests & Inspection Cable PCUT & PCUT-A (Table T1) 1. NOTE 1: ENVIRONMENTAL STRESS CRACK RESISTANCE TEST 1.1. The test detailed in IEC Publication 538-A Procedure B shall be substituted for that detailed in ASTM D when the moulded sheet notch dimensions for medium density polyethylene are determined (See Note in IEC 538- A Sub-Clause 2.6.2) 1.2. The following procedures for the preparation of the moulded sheet for environmental crack resistance tests on PE Sheets are detailed as an aid and clarification to the procedures detailed in ASTM-D Preparation Of Moulded Sheet For Crack Resistance Test (Preparation Of The Mould) Using a solvent such as trichlaro-ethylene, throughly clean a piece of smooth aluminium foil 230 mm 200 mm. Place this parting sheet on a backing plate of smooth hard aluminium 230 mm 200 mm 6 mm or more thick, having a thermometer well sunk into one edge extending to the centre of the plate. On this is placed a spacing frame consisting of a 230 mm 200 m 3.30 mm thick plate of stainless steel or other suitable material having a rectangular hole 180 m 150 mm with its internal corners rounded to a radius of 3 mm. Place a calculated quantity of polyethylene compound in the opening of the spacing frame in such a way that the material will flow from the centre towards the sides of the frame and avoid leaving bubbles in the moulded sheet. (The approximate quantity of polyethylene required in grams is equal to 27 density thickness (in m) + 2. Cover the charge with a second backing plate also fitted with a thermometer Moulding Preheat the press to 170 C. Insert the mould, prepared as above and close the press using light pressure only. Hold until the thermometers indicate that the material has reached a temperature of C (Approximately five minutes) and then increase the pressure to a force of 16,000 Kg and maintain it thus for two minutes. Allow the temperature to drop to 340 C in approximately five minutes before releasing the pressure. Remove the backing plates without disturbing the aluminium parting sheets of the frame. This constitutes the annealing Annealing Apparatus A circulating-air oven, capable of maintaining a temperature of 145 ± 20 C fitted with a device for lowering the temperature at a constant rate of 5 ± 0.5 C per hour down to at least 400 C Separator plates Smooth aluminium plates 230 mm mm hick Follow-Up Plates Smooth aluminium plates 145 mm 170 m 1.6 mm thick COVER PLATES A smooth brass plate 230 mm 230 mm 10 mm thick with a thermometer well drilled into one edge and extending to the centre of the plate. Annealing Stack the annealing s horizontally on a shelf or suitable support so as to permit free circulation of air on all sides of the stack as follows: Place a separator plate at the bottom. Centre a follow-up plate plus a separator plate on each. Place the cover plate on top of the stack. The follow-up plates are extended to fit in the depression of the annealing to maintain good contact between the parting sheets and the polyethylene during the expansion on melting and contraction on cooling. After assembling the stack of annealing s in the oven, heat the oven until the thermocouple inserted in the brass cover plates records 145 C. Maintain the oven at 145 ± 2 C/hour, then begin cooling at 5.0 ± 0.50 C/hour by means of a mechanical device. The actual cooling rate should be recorded by a graphical recorder. Remove the annealing s when they have reached 40 C or less, and remove the parting sheets and moulding frames. A properly prepared sheet should contain no bubbles or sink marks except possibly near the edge. Sheets containing such blemishes may be reprocessed at once Determination Of Residual Strain Preheat the petri dish containing 3-6 mm of talc to 140 ± 2 C in an air oven. Cut two specimens 13 mm by 38 m from different parts of the test sheet with their long axes perpendicular to each other. Place these specimens on the preheated talc, and maintain at 140 ± 20 C for 30 minutes, then remove the dish with the specimens and allow to cool to room temperature. A specimen that exhibits less than 10 percent shrinkage as measured by a scale readable to 0.1 mm and whose surface remains smooth and regular 6 of 7
7 indicates a satisfactory test sheet. The outside 6 mm of such sheets should be trimmed and discarded before the sheet is used. 7 of 7
UGVCL/SP/591/11KV HT AB CABLE
TECHNICAL SPECIFICATION FOR 11KV AERIAL BUNCHED CABLES FOR OVERHEAD LINES (CROSSED LINKED POLYTHENE DRY GAS CURED) 1. SCOPE This specification covers requirements of XLPE insulated, 11 KV Aerial Bunched
More informationQuality Reliability Innovation. ISO 9001 : 2000 CERTIFIED BY AFAQ No. QUAL / 1997 / 7034 a COPPER TELECOMMUNICATION CABLES
Quality Reliability Innovation ISO : CERTIFIED BY AFAQ No. QUAL / 7 / 7 a COPPER TELECOMMUNICATION CABLES COPPER TELECOMMUNICATION CABLES CONTENTS 7 NOTICE INTRODUCTION QUALITY ASSURANCE RECOMMENDED ORDERING
More informationKALPANA INDUSTRIES LTD. TECHNICAL DATA SHEET
1 KALPANA INDUSTRIES LTD. TECHNICAL DATA SHEET KI XL - 03 / KI-SC 10 TWO COMPONENT AMBIENT CURABLE POLYETHYLENE COMPOUND FOR INSULATION OF LOW VOLTAGE POWER CABLE DESCRIPTION : KI polyethylene compound
More informationGulf Cable & Electrical Ind. Co.
CONTENTS INTRODUCTION PRODUCT RANGE I PRODUCT DATA TABLES Irrigation 1 Coaxial s for T.V/ Satellite Antenna etc 2 Data Transmission s - 4 pair 24 AWG 3 TELEPHONE CABLES Telephone cables CCP-LAP & CCP-LAP-SS
More informationTECHNICAL SPECIFICATION FOR LOW-FREQUENCY CABLES AND WIRES WITH PVC INSULATION AND PVC SHEATH
Rev. 1:2007 TECHNICAL SPECIFICATION FOR LOW-FREQUENCY CABLES AND WIRES WITH PVC INSULATION AND PVC SHEATH Suruhanjaya Komunikasi dan Multimedia Malaysia Off Pesiaran Multimedia, 63000 Cyberjaya, Selangor
More informationR=Required by Lab S=May be subcontracted IEC SYSTEM FOR CONFORMITY TESTING AND CERTIFICATION OF ELECTRICAL EQUIPMENT COMMITTEE OF TESTING LABORATORIES
IEC SYSTEM FO CONFOMITY TESTING AND CETIFICATION OF ELECTICAL EQUIPMENT COMMITTEE OF TESTING LABOATOIES TESTING AND MEASUING EQUIPMENT/ALLOWED SUBCONTACTING Power cables with extruded insulation and their
More informationPROFIBUS cable. for PROFIBUS-PA and -DP 10/63-6.46 EN
for PROFIBUS-PA and -DP 10/63-6.46 EN CPN 080/CPE 080-Ex PROFIBUS-PA basis cable AWG 18, 0.88 mm 2 Use For fixed installation indoor and outdoor, on racks and in conduits. Application Fieldbus cable for
More informationSpecializing in the cable business for over 38 years, PT. SUPREME CABLE
Specializing in the cable business for over 38 years, PT. SUPREME CABLE MANUFACTURING & COMMERCE Tbk. (PT. SUCACO Tbk) has grown steadly to become a largest and leading cable manufacturer, with international
More informationFestoon 715 P PUR cable for flexible application in festoon systems
CABLES FOR CRANE AND CONVEYOR APPLICATIONS Festoon 715 P PUR cable for flexible application in festoon systems S AB BRÖCKSKES D-VIERSEN Festoon 715 P 1 x 16.0 mm 2 C Marking for Festoon 715 P 07150162:
More informationCable Guide. Cables, Connectors & Tools for installation of quality networks. TRIAX - your ultimate connection
Cable Guide Cables, Connectors & Tools for installation of quality networks TRIAX - your ultimate connection A Selection of the best Triax TX Cable range optimised for digital reception Simplification
More informationDuPont Kapton. polyimide film. General Specifications
DuPont Kapton polyimide film General Specifications Introduction DuPont manufactures and sells a variety of highquality polyimide film products in conformance with ISO 9002 certification. These specifications
More informationCommunication, Signal & Data Cables
Communication, Signal & Data Cables Used for indoor installation and interconnection of transmission, telephone, telegraph and electronic equipment as well as media equipments www.alfanar.com Communication
More informationHINDUSTAN PETROLEUM CORPORATION LIMITED ENGINEERING & PROJECTS GRESHAM ASSURANCE HOUSE, 2 ND FLOOR, A-1595(3) 1-A, SIR P M ROAD, FORT MUMBAI-400 001
NEW POL DEPOT AT HINDUSTAN PETROLEUM CORPORATION LIMITED ENGINEERING & S GRESHAM ASSURANCE HOUSE, 2 ND FLOOR, A-1595(3) 1-A, SIR P M ROAD, FORT MUMBAI-400 001 TECHNICAL SPECIFICATION OF XLPE, FRLS LT CABLES
More informationGulf Cable & Electrical Ind. Co.
CONTENTS INTRODUCTION PRODUCT RANGE I PRODUCT DATA TABLES XLPE INSULATED 600/1000V CABLES Two Core Cables CU/XLPE/PVC/LC/PVC/SWA/PVC 1 Three Core Cables CU/XLPE/PVC/LC/PVC/SWA/PVC 2 Four Core Cables CU/XLPE/PVC/LC/PVC/SWA/PVC
More informationIEEE POWER ENGINEERING SOCIETY CHICAGO CHAPTER THE OKONITE COMPANY WEDNESDAY JANUARY 11, 2006 JIM FITZGERALD ENGINEERING LINGO
IEEE POWER ENGINEERING SOCIETY CHICAGO CHAPTER THE OKONITE COMPANY WEDNESDAY JANUARY 11, 2006 JIM FITZGERALD ENGINEERING LINGO WHEN YOU HEAR AN ENGINEER SAY A NUMBER OF DIFFERENT APPROACHES ARE BEING IMPLEMENTED
More informationSCHEDULE ' A' TECHNICAL SPECIFICATION FOR 11/22/33KV H.T.XLPE POWER CABLE FOR DISTRIBUTION NETWORK IN MAHARASHTRA (SPECIFICATION NO.
SCHEDULE ' A' TECHNICAL SPECIFICATION FOR 11/22/33KV H.T.XLPE POWER CABLE FOR DISTRIBUTION NETWORK IN MAHARASHTRA (SPECIFICATION NO.MM/I/HTXLPE/2006) MAHARASHTRA STATE ELECTRICITY DISTRIBUTION CO.LTD.
More informationRE-ENTERABLE SPLICE CLOSURE KITS. (For Air Core None Pressurized Cable)
Triple T Broadband Public Co., Ltd. Outside Plant Standard Sector Specification No. OES-001-027-04 Issued: RE-ENTERABLE SPLICE CLOSURE KITS (For Air Core None Pressurized Cable) 1. SCOPE 1.1. This specification
More informationDraka Industrial Cable GmbH
A) Preparation of cable ends To enable the stranding of the cores after connecting main and earth cores, each of the cable ends to be connected are laid in a double loop with righthand turn and then fixed
More informationPROFIBUS cable. PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications
Data Sheet 10/63-6.47-EN Rev. D PROFIBUS cable PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications PROFIBUS PA cables Non-Ex (Hazardous) applications Ex (Hazardous) applications
More informationPRODUCT SPECIFICATION
ipass TM / ipass+ TM 0.8 mm PITCH I/O CONNECTOR SYSTEM EXTERNAL ipass / ipass+ of TABLE OF CONTENTS.0 SCOPE... 3.0 PRODUCT DESCRIPTION... 3. PRODUCT NAME AND SERIES NUMBER(S)... 3. DIMENSION, MATERIALS,
More informationMICROCABLES. A complete vision of your connectivity needs. Catalogue
MICROCABLES A complete vision of your connectivity needs Catalogue ELECTRONIC Filotex Introduction Application Nexans s line of microcables is designed towards the increasing requirements of electronics
More informationTwo Position Cable-to-Board Power Connector System (Right Angle/Straight) with Coding Contacts
Product Specification 108-19346 17 APR 2013 Rev F Two Position Cable-to-Board Power Connector System (Right Angle/Straight) with Coding Contacts 1. SCOPE 1.1. Content NOTE The product may not perform according
More informationCables, Cable Laying & Accessories Manual
Distribution Business Cables, Cable Laying & Accessories Manual Database ref: File Ref: Title Page & Revision Log For Cables & Access v4 - Nov 2003.doc Manual Name: Cables & Accessories Manual Version
More informationTECHNICAL SPECIFICATION
TECHNICAL SPECIFICATION 4 PAIR UTP CABLE (ENHANCED CATEGORY 5) PVC (CM Grade) Page 1 of 6 1. SCOPE This specification is based on the specifications of UL 444, ANSI/TIA/EIA-568-B.2, UL 1685 and covers
More informationFLEXIBLE COPPER & ALUMINIUM CONNECTIONS. Product Range 1 VGL - ALLIED CONNECTORS
Product Range ROUND STRANDED COPPER CABLE Electrolytic Copper / Oxygen Free Copper Conforms to DIN 46438 Standards Finish: Bare Copper / Tinned / Silver-plated ROUND BRAID / ROUND STRANDED CABLE WITH OVERALL
More informationDOUBLE STAINLESS STEEL TUBE DTS FIBER OPTIC CABLE FTSF-FSUTS(DTS)
DOUBLE STAINLESS STEEL TUBE DTS FIBER OPTIC CABLE FTSF-FSUTS(DTS) Double Jelly Filled Stainless Steel Tube General Description This document specifies non armour sensing fiber cable with double stainless
More informationProduct Specification
Product Specification Model No.: DC-240-L01-00-TR Description: H=3.00mm Horizontal SMD DC Power Jacks Pin Shaft Diameter: 0.65mm Packing Method: Tape & Reel (600pcs./R) 1. General 1a. Scope The jacks should
More informationTECHNICAL DATA SHEET GRILON BG-15 S
TECHNICAL DATA SHEET GRILON BG-1 S Grilon BG-1 S is a heat stabilised PA6 injection moulding grade with 1% glass fibres. Grilon BG-1 S has the following important properties: Excellent surface finish Easy
More informationGUARDRAIL POST STEEL
GUARDRAIL POST STEEL Guardrail posts meeting materials certification are evaluated and checked for: 1. Dimensional acceptance 2. Physical test results a. Chemical b. Physical 3. Galvanized or painted coating
More informationOutside Telephone Cable
Outside Telephone Cable Filled Core. Moisture Barrier. Description Soft copper wires insulated with high density polyethylene, foam skin or solid. Filled core, conformed by groups of pairs or by unit of
More informationKNOW YOUR OPTIONS: 230 KV POWER CABLES
KNOW YOUR OPTIONS: 230 KV POWER CABLES 71 CONDUCTOR MATERIAL AND SIZE Conductor material is a matter of both customer preference and required current carrying capacity At 230 kv, copper is most common
More informationCommercial Coaxial Cable
Commercial Coaxial Cable For the Best in COMMERCIAL TV Reception Solutions! Do you require a Digital TV reception system for your next project? Matchmaster can supply For The Best Design and supply of
More informationFigure 1 (end) Updated document to corporate requirements Added text to Paragraph 2.4
This specification covers the requirements for application of ELCON Drawer Series Connectors: True Hot Plug, Blind Mating Mixed Signal and Power Connectors. These connectors are designed for use in pluggable
More informationHIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS
BSW HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS BSW is a fully reinforced Pre-Applied system membrane designed for horizontal and vertical external blind-side
More informationKNOW YOUR OPTIONS: 69 KV XLPE POWER CABLE
Know Your Options: 69 kv XLPE Power Cable 3 material and size material is a matter of both customer preference and required current carrying capacity Copper conductor common for larger loads When both
More informationGood Boards = Results
Section 2: Printed Circuit Board Fabrication & Solderability Good Boards = Results Board fabrication is one aspect of the electronics production industry that SMT assembly engineers often know little about.
More informationEDS 02-0027 11KV TRIPLEX CABLE
THIS IS AN UNCONTROLLED DOCUMENT, THE READER MUST CONFIRM ITS VALIDITY BEFORE USE Document Number: EDS 02-0027 ENGINEERING DESIGN STANDARD EDS 02-0027 11KV TRIPLEX CABLE Network(s): EPN, LPN, SPN Summary:
More information6 ELECTRICAL PARAMETERS
6 ELECTRICAL PARAMETERS For power, low voltage and medium voltage cables, cross section nominal areas are calculated in taking into account several parameters as: permissible current carrying capacities
More informationTransformer Bushings for GIS
Transformer Bushings for GIS Oil to SF6 Connections GARIP RTKG 725-55 kv SQS certified ISO 91 / ISO 141 Bushings RIP - Technology for SF6 / Oil - Bushings In modern metal enclosed switchgear SF6 -gas is
More informationDC RESISTANCE TEST AND WEIGHT MEASUREMENT TEST ON PRAGUE ACCC/TW CONDUCTOR STRANDED BY PT KMI WIRE AND CABLE Tbk COMPANY
To: Dr. Eric Bosze CTC Cable Corporation 2026 McGaw Avenue Irvine, CA 92614 USA DC RESISTANCE TEST AND WEIGHT MEASUREMENT TEST ON PRAGUE ACCC/TW CONDUCTOR STRANDED BY PT KMI WIRE AND CABLE Tbk COMPANY
More informationCompany and Product Presentation
Company and Product Presentation Company Presentation NBG Systems & FCT are private companies owned by NBG Holding Both are Austrian companies, operating under the highest European Union requirements &
More information2 8 k V, 1 / C, T R X L P E I N S U L A T E D, F L A T S T R A P S H I E L D E D C A B L E, C O M P R E S S E D S T R A N D I N G
Seattle Cit y Light 1 of 4 2 8 k V, 1 / C, T R X L P E I N S U L A T E D, F L A T S T R A P S H I E L D E D C A B L E, C O M P R E S S E D S T R A N D I N G 1. Scope This standard covers the detailed requirements
More informationSection 5 161 kv Power Cables
Know Your Options: 161 kv Power Cable 61 material and size material is a matter of both customer preference and required current carrying capacity Copper conductor common for larger loads When both copper
More informationcoaxial cable coaxial Cable CERTIFIED 100% certified coaxial cable A cable that is marked Televés, no doubt is a certified cable
COAXIAL CABLE coaxial Cable 100% certified coaxial cable coaxial cable CERTIFIED The step ahead undertaken by Televés to improve its service and technical excellence, is now reflected in this new challenge.
More informationMEDIUM VOLTAGE CABLES Up to and including 36 KV
MEDIUM VOLTAGE CABLES Up to and including 6 KV NOTICE As this catalogue is not intendedto cover all of LIBAN CABLES SAL possibilities in special cables manufacturing, the hereafter listing of the types
More informationFLEXIBLE CIRCUITS MANUFACTURING
IPC-DVD-37 FLEXIBLE CIRCUITS MANUFACTURING Below is a copy of the narration for DVD-37. The contents of this script were developed by a review group of industry experts and were based on the best available
More informationPressure monitoring equipment for oil-sf 6. bushings, type GOEK
Pressure monitoring equipment for oil-sf 6 bushings, type GOEK Installation and maintenance guide 5693 827-6 en, Rev. 3, 2002-01-30 This document must not be copied without our written permission, and
More information3.6/6 kv XLPE insulated cables 5. 6/10 kv XLPE insulated cables 15. 8.7/15 kv XLPE insulated cables 25. 12/20 kv XLPE insulated cables 35
CONTENTS INTRODUCTION 1 Cable selection, cable specification, cable services CABLES Constructional data: 3.6/6 kv XLPE insulated cables 5 SECTION 1 6/10 kv XLPE insulated cables 15 SECTION 2 8.7/15 kv
More informationA World Class Manufacturer of Induction Bends
A World Class Manufacturer of Induction Bends COFELY FABRICOM BENDING A leading position in bending High Flexibility and Close Tolerances As a world leading manufacturer of pipe bends, produced by induction
More information1ZSE 2750-105 en, Rev. 8. Transformer bushings, type GOE and GOE(2) Technical guide
1ZSE 2750-105 en, Rev. 8 Transformer bushings, type GOE and GOE(2) Technical guide Original instruction The information provided in this document is intended to be general and does not cover all possible
More informationMILMAN & ASSOCIATES STRUCTURAL CONSULTING ENGINEERS/ PROJECT MANAGERS
MILMAN & ASSOCIATES STRUCTURAL CONSULTING ENGINEERS/ PROJECT MANAGERS May 29, 2013 Revision B Structural Guideline for Design and Installation Holes in Composite Floor Slab Terminal 3, Departure Level
More informationFIRE RESISTANT CABLE CONSTRUCTION OF CABLES
FIRE RESISTANT CABLE In all fire disasters, fire smoke, heat and toxic fumes are the main obstacles to safe evacuation of a building or area. A major contribution towards overcoming these hazards is the
More information140 146 rue E. Delacroix / BP 1 F 91211 Draveil cedex FRANCE Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70. Issue 2 01/10/2003-2 -
Space cables Issue 2 01/10/2003-2 - C O N T E N T ESCC Qualified Products Nexans P/N ESCC SP Pages 1871-871 3901/001 359 3/8 1872-872 3901/002 358 9/14 MTV - BTV 3901/013 199 15/19 50 CIS 3902/001.01 189
More informationCOAXICON Contacts. RF Coax Connectors. Product Facts
COXICON Contacts Product Facts Tyco Electronics provides a variety of contacts for coaxial connectors Contacts are available in a range of sizes that may be used with the various types of coaxial cable
More informationDENSO WATERPROOFING SYSTEMS
DENSO WATERPROOFING SYSTEMS Approved Quality Management System AS/NZS ISO 9001:2008 Lloyds Register Certificate N o Mel 0927759 Denso (Australia) Pty Ltd A MEMBER OF WINN & COALES INTERNATIONAL 411 413
More informationTITANIUM FABRICATION CORP.
TITANIUM FABRICATION CORP. Titanium, Zirconium, and Tantalum Clad Construction General Considerations In many applications, particularly for large pressure vessels designed for high temperature and pressure,
More information114-22008. 8-Position Cat5e (EMT) Modular Plug Connectors. Application Specification
Application Specification 114-22008 02/May/2008 Rev H 8-Position Cat5e (EMT) Modular Plug Connectors NOTE All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are
More informationINJECTION MOULD DESIGN: MARPLEX PVC RESINS
MACHINE RECCOMENDATIONS PVC requires reciprocating screw injection moulding machine with a plasticising screw to produce homogeneous melt. It is recommended that a shot weight of the part should take two
More informationDirectory chapter 04
M Directory chapter 04 D-Sub Mixed subminiature D connectors New Page D-Sub mixed connector system general information................... 04.02 Contact arrangements............................................
More informationULTIMATE SNAP-N-SEAL
ULTIMATE SNAP-N-SEAL F Series Compression Connectors Thomas & Betts introduces the Ultimate Snap-N-Seal Compression Connector, the newest addition to the Snap-N-Seal system. Look for the classic design
More informationConnect. Cable preparation and cutting tools
Connect Cable preparation and cutting tools 390 Our range of cable preparation tools includes hand-operated & ratchet action cable cutting tools, wire preparation & stripping tools and SWA & hydraulic
More informationQUASAR ELECTRONICS KIT No. 1015 ELECTRONIC MOSQUITO REPELLER
QUASAR ELECTRONICS KIT No. 1015 ELECTRONIC MOSQUITO REPELLER General Description This simple circuit can prove itself worth many times its value (which is very reasonable anyway) in getting rid of mosquitoes
More informationStandard Buccaneer - Ethernet
IP6 rated compliant PUR jacket on cable Shielded system shielded coupler Shroud on RJ45 Screw coupling Rewireable flex connector PCB mounted panel connector IDC termination panel connector Earth lead version
More informationMETHOD OF STATEMENT FOR STATIC LOADING TEST
Compression Test, METHOD OF STATEMENT FOR STATIC LOADING TEST Tension Test and Lateral Test According to the American Standards ASTM D1143 07, ASTM D3689 07, ASTM D3966 07 and Euro Codes EC7 Table of Contents
More informationElectrical Safety Products
Electrical Safety Products Trelleborg Electrical Safety Products A safe working environment is important in all industries, but in the electrical generation and supply industry, it is paramount. Trelleborg
More informationitaltec PRINTED CIRCUITS EQUIPMENT PRINTED CIRCUITS EQUIPMENT Insulator machines Echting machines Special equipment and machines
PRINTED CIRCUITS EQUIPMENT PRINTED CIRCUITS EQUIPMENT Insulator machines Echting machines Special equipment and machines On customer request it is possible to supply: Benches for PCB Oven for PCB Chemicals
More informationThe Contractor shall furnish and install all shielded power cable suitable for use on this project.
Section 16122 PRIMARY POWER CABLES PART 1 GENERAL: WORK INCLUDED The Contractor shall furnish and install all shielded power cable suitable for use on this project. RELATED WORK Section 16020: Tests SUBMITTALS
More informationTS 813 GROUNDING AND BONDING TTD 813.001 TRAFFIC SIGNAL INSTALLATION AND CONTROLLER CABINET GROUNDING SYSTEM TTD 813.005 CONTROLLER CABINET GROUNDING
TORONTO TRANSPORTATION January 2012 TS 813 GROUNDING AND BONDING TABLE OF CONTENTS 1. DRAWINGS TTD 813.001 TRAFFIC SIGNAL INSTALLATION AND CONTROLLER CABINET GROUNDING SYSTEM TTD 813.005 CONTROLLER CABINET
More informationNetwork Standard Advice No. 1420C 9/6/2011
Network Standard Advice No. 1420C 9/6/2011 TO: Customers, Service Providers and Ausgrid Staff. Advisory Note on Changes to the Use of 11kV Cable Types. Introduction This Network Standard Advice (NSA) provides
More informationHigh Voltage Systems. Today. The history of cables
High Voltage Cables High Voltage Systems Today Prysmian Cables and Systems B.V. is part of the Prysmian Group, a leading player in the industry of high-technology cables and systems for energy and telecommunications,
More informationInternational Electrotechnical Commission Standards
International Electrotechnical Commission Standards Standard IEC 60028 IEC 60038 IEC 60050-461 IEC 60055-1 IEC 60055-2 IEC 60092-101 IEC 60092-350 IEC 60092-351 IEC 60092-352 IEC 60092-353 IEC 60092-354
More informationCABLE SPECIFICATION CAN CAB RJ45-SUBD9
CABLE SPECIFICATION All technical information contained in this document is the exclusive property of STI and may neither be used nor disclosed without its prior written consent. AAV 33801 1/8 Connector
More informationCOATING & WRAPPING OF UNDERGROUND PIPING
CONSTRUCTION STANDARD SPECIFICATION DOCUMENT NO :SEC-PJ-000-SPC-PI-008 TOTAL PAGES : 8 Page 1 of 8 CONTENTS 1. SCOPE 2. DEFINITION 3. CODES AND STANDARDS 4. MATERIALS Page 2 of 8 1. SCOPE This specification
More informationCables. Accessories. For Force, Torque and Strain Sensors
Accessories Cables For Force, Torque and Strain Sensors Charge mode, high impedance piezoelectric measurement demands highly insulated coaxial cables and connectors to ensure an insulation resistance greater
More informationCHAPTER VIII LINE PLANT SYSTEM COMMUNICATION THROUGH RE CABLE
CHAPTER VIII LINE PLANT SYSTEM COMMUNICATION THROUGH RE CABLE 8.1 SYSTEM 8.1.1 Armoured, screened underground cables are used for control communication in electrified areas to limit induction effect. 8.2
More informationCORNING CABLE SYSTEMS GENERIC SPECIFICATION FOR TIGHT BUFFER OPTICAL FIBER CABLES FOR INTER- AND INTRABUILDING APPLICATIONS.
CORNING CABLE SYSTEMS GENERIC SPECIFICATION FOR TIGHT BUFFER OPTICAL FIBER CABLES FOR INTER- AND INTRABUILDING APPLICATIONS September 2006 Revision 7 Corning Cable Systems reserves the right to update
More informationFault location on power cables. Fault location on power cables
Fault location on power cables Fault location on power cables Contents: 1. Introduction 2. Construction of power cables 3. Cable faults 01. Introduction Fault location on communication and power cables
More informationApr 17, 2000 LAB MANUAL 1811.0
Apr 17, 2000 LAB MANUAL 1811.0 1811 BULK SPECIFIC GRAVITY (GMB) AND DENSITY OF COMPACTED BITUMINOUS SPECIMENS USING PARAFFIN OR PARAFILM ASTM Designation D 1188 (MN/DOT Modified) 1811.1 SCOPE This test
More informationAluminium foil properties: Applications of aluminium foils and thin gauge strips in thickness below 0,50 mm:
1 ALUMINIUM FOILS AND THIN GAUGE STRIPS The year 2010 has been celebrated as the 100th anniversary of aluminium foil. Ever since the beginning in 1910 the usage of foil has been growing and products developed
More informationSERIES NG 1800 STRUCTURAL STEELWORK
MANUAL OF CONTRACT DOCUMENTS FOR HIGHWAY WORKS VOLUME 2 NOTES FOR GUIDANCE ON THE SPECIFICATION FOR HIGHWAY WORKS SERIES NG 1800 STRUCTURAL STEELWORK Contents Clause Title Page NG 1800 (08/14) General
More informationOperating Instructions
Operating Instructions Cable Glands Ex d and Ex e with Compound > Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Safety Information...3 4 Designated Use...4 5 Technical Data...4
More informationMEDIUM VOLTAGE POWER CABLES
MEDIUM VOLTAGE POWER CABLES CONTENTS 1 GENERAL INTRODUCTION 4 TECHNICAL INFORMATION 15 25 35 45 Single Core XLPE Insulated PVC Sheathed Cables UNARMOURED CABLES COPPER UNARMOURED CABLES ALUMINUM ALUMINUM
More informationFlex Circuit Design and Manufacture.
Flex Circuit Design and Manufacture. Hawarden Industrial Park, Manor Lane, Deeside, Flintshire, CH5 3QZ Tel 01244 520510 Fax 01244 520721 Sales@merlincircuit.co.uk www.merlincircuit.co.uk Flex Circuit
More informationNaue GmbH&Co.KG. Quality Control and. Quality Assurance. Manual. For Geomembranes
Naue GmbH&Co.KG Quality Control and Quality Assurance Manual For Geomembranes July 2004 V.O TABLE OF CONTENTS 1. Introduction 2. Quality Assurance and Control 2.1 General 2.2 Quality management acc. to
More informationCONFLEX ELECTRIC CABLE
CONFLEX ELECTRIC CABLE CONFLEX - 0.6/1kV Flexible VSD/EMC Cables Applications WW VSD/EMC cables are manufactured for use where electrical interference distorts signal transmission in electric motors. Standard
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 60502-1 Second edition 2004-04 Power cables with extruded insulation and their accessories for rated voltages from 1 kv (U m = 1,2 kv) up to 30 kv (U m = 36 kv) Part 1: Cables
More informationScreened cable and data cable segregation
December 2007 Screened cable and data cable segregation Can an armoured power cable be considered a screened cable and how does this relate to power and data cable segregation? The short answer is yes;
More informationINTERNATIONAL HOCKEY FEDERATION PERFORMANCE REQUIREMENTS AND TEST PROCEDURES FOR HOCKEY BALLS. Published: April 1999
INTERNATIONAL HOCKEY FEDERATION PERFORMANCE REQUIREMENTS AND TEST PROCEDURES FOR HOCKEY BALLS Published: April 1999 CONTENTS 1 Introduction 2 Test Procedures General 3 Standards and Specific Test Procedures
More informationSeawater corrosion resistant piping systems for large diameters up to 100 / 2.5 metres O.D.
OSNA -10 Copper-Nickel Lined Pipes Seawater corrosion resistant piping systems for large diameters up to 100 / 2.5 metres O.D. KME Germany AG & Co. KG Copper-Nickel Lined Pipes [GB] Member of the KME Group
More informationAMP Standard Terminals and Splices. RoHS. Ready
AMP Standard Terminals and Splices RoHS Ready Table of Contents Product Facts Solderless terminals and splices performs up to today s standards for reliable termination in applications ranging from control
More informationCable Installation Notes
Cable Installation Notes June 2006 Table of Contents Cable Pulling... 2 Bending Radius... 2 Pulling Tension... 3 Friction... 3 Installation with Rollers... 4 Installation without Rollers... 4 Pulling Tension
More informationMorgue refrigeration unit
Morgue refrigeration unit The Morgue refrigeration units are made of sturdy, self-supporting walls, floor and ceiling elements. They are delivered in separate components and are to be assembled on site
More informationVIPERFLEX ELECTRIC CABLE
VIPERFLEX Flexible Low Voltage Electric Cable - 0.6/1kV (Rubber insulated) H07 RN-F & H07 BN-F Single Core 2-Core 2-Core and Earth 3-Core and Earth 4-Core and Earth Multi-Core and Earth H07 RCN-F & H07
More informationFlexible Circuit Simple Design Guide
Flexible Circuit Simple Design Guide INDEX Flexible Circuit Board Types and Definitions Design Guides and Rules Process Flow Raw Material Single Side Flexible PCB Single Side Flexible PCB (Cover layer
More informationTECHICAL SPECIFICATION Conductive Elastomer Extruded Gaskets
Pag. 1/8 TECHICAL SPECIFICATION Conductive Elastomer Extruded Gaskets Electrically conductive silicone gaskets are manufactured in different standard profiles and upon client request, in silicone and fluorosilicone,
More information100% EMI Emission Containment
100% EMI Emission Containment Designed for Longer Service Life Highly Flexible for Easier Handling and Faster Installation Authorized Distributor Industrial VFD Cables Index n Variable Frequency Drive
More informationSIGRAFLEX EMAIL. Properties. Applications
Multilayer sealing sheet, adhesive-free made from flexible graphite foil reinforced with stainless steel foils especially for use in PTFE envelope gaskets SIGRAFLEX EMAIL has been developed specially for
More informationThermocouple Wire & Cable
Thermocouple Wire & Cable TRM Ltd & MICC Ltd Temperature House 21 Sedling Road Wear Industrial Estate Washington Tyne & Wear NE38 9BZ PVC Extruded Example Applications: Permanent Sensor Fabrication, Laboratories,
More information08. SEK IDC CONNECTORS
. IDC CONNECTORS connectors for flat cables enable simple and, cost-optimized device configuration. connectors are preferably used for connection within the device. HARTING offers a broad range of these
More information