The Quality Connection. BETAflam Fire Resistant Safety Cables
|
|
|
- Hannah Hilary Stokes
- 9 years ago
- Views:
Transcription
1 The Quality Connection BETAflam Fire Resistant Safety Cables
2 2 Contact Consulting and sales Switzerland Phone +41 (0) Fax +41 (0) Germany Phone +49 (0) Fax +49 (0) [email protected] Safety instructions Cables are to be used for the designated applications only. In case of failure or damage to the cable or connector, switch off power immediately and replace all damaged parts. Maintenance, repair and replacement of the cables and connectors may only be carried out by authorised and trained personnel. Waiver While the information contained in this document has been carefully compiled to the best of our knowledge, it is not intended as a representation or warranty of any kind on our part regarding the suitability of the products concerned for any particular use or purpose and neither shall any statement contained herein be construed as a recommendation to infringe any industrial property rights or as a license to use any such rights. The suitability of each product for any particular purpose must be checked beforehand with our specialists. Our policy is one of continuous material and product development. We reserve the right to offer alternatives consistent with our manufacturing programme at the time of enquiry. All information concerning material properties, fire performance, construction, electrical and technical data, prices etc. reflects our current level of knowledge and is provided without obligation. Dimensions and weights are only given as a guide. The specifications may change any time without prior notice. RoHS Compliance We confirm that from 1st January 2006 onwards, all products listed in this catalogue, are manufactured in full compliance with the EU Directive 2002/95/EG (RoHS)
3 3 Content Page Page LEONI The Quality Connection. Technical information The LEONI Group 4 People can move about in safety. 6 Safety from one source. 7 BETAflam Safety and Communication Cables Overview 8 FRT-MI 90 / Single Core / Single Insulated 10 FRT-MI 90 / Single Core / Double Insulated 13 FR-MI 90 / Single Core / Single Insulated 16 FR-MI 90 / Single Core / Double Insulated 19 FR-MI 110 / Single Core / Single Insulated 22 FR-MI 110 / Single Core / Double Insulated 25 FR-MI 110 / Multicore 28 FR-MI 110 / Multicore / Steel Tape Armour (STA) 31 FR-MI 110 / Multicore / Steel Wire Armour (SWA) 34 FR-MI 110 Comms Cables 37 Current rating 44 Core identification 48 Halogen free 49 Degree of acidity of combustion gases 49 Smoke density 50 Flame retardant 50 No flame propagation 51 Circuit integrity under fire 51 Circuit integrity with mechanical shock 52 System integrity 52 Resistance to fire alone 53 Resistance to fire with water 53 Resistance to fire with mechanical shock 54 Summary of standards 55 General handling, storage and installation Instructions 56 Duration of system circuit integrity in the building laws 60 General Conditions of Sale and Delivery 61 Further products 63 BETAflam Safety Power and Communication Cables Overview 40 BETAfixss Laying System Overview 41 Flexible BETAtherm and BETAflam Cables Overview 42 Flexible BETAtrans Cables Overview
4 4 LEONI The Quality Connection The LEONI Group Cable and cable system solutions for different industrial markets. LEONI is a leading supplier of cable systems and related services for the automotive industry and various other industrial sectors. Our group of companies employs more than 59'000 people in 33 countries. Corporate vision, highest quality and innovative power have made us one of the leading cable manufacturers in Europe. LEONI develops and produces technically sophisticated products ranging from wire and optical fibers to cables through to complete cable systems and also offers the related services. Moreover, the product portfolio comprises strands, standardised cables, hybrid cables, glass fiber as well as special cables, cable harnesses, wiring systems components and fully assembled systems for applications in various industrial markets. Products and services portfolio at a glance Service Cable harnesses Cable systems / Wiring Systems Sensors Relay and safety systems Engineering Copper cables Wires & strands Hybrid cables Optical fibers Optical cables Connectors
5 LEONI The Quality Connection 5 Your markets our strength. As diverse as our product and service range are the markets and sectors LEONI is supplying. We focus our activities on customers in the fields of Automotive & Commercial Vehicles, Industry & Healthcare, Communication & Infrastructure, Electrical Appliances and Conductors & Copper Solutions. We are among the leading European suppliers in the Communication & Infrastructure market to which at LEONI as a cable manufacturer also belong activities in the fields of infrastructure & data communications, industrial plant projects, solar- and wind power, energy & telecommunications, irradiation crosslinking and traffic engineering. Our customers benefit worldwide from innovative as well as reliable and long-lasting products of high quality. LEONI we create the best connection for your future. for further informations LEONI's core markets Automotive & Commercial Vehicles Industry & Healthcare Communication & Infrastructure Electrical Appliances Conductors & Copper Solutions
6 6 LEONI The Quality Connection People can move about in safety. Protection to life and property is assured. Public buildings Our cables and support systems energise the safety equipment and escape routes. Train stations, underground stations, airports Lighting, emergency exits and signalling ensure safety in infrastructure buildings. Thanks to their system integrity during exposure to fire, our products make a crucial contribution in critical situations. Transport routes Our products are used for the markings, illumination and control of transport routes. Tunnels With our cables and support systems we safeguard the lighting and optical control equipment as well as power supply to ventilators and escape routes for emergency situations. Building and transport infrastructure nowadays have high requirements in terms of protection against disruption and fire. Developers and planners take their responsibility seriously and impose higher expectations on the safety technology of buildings such as hospitals, event facilities and office complexes. This ensures that people can escape in the event of fire and that successful firefighting minimises the damage caused. While infrastructure is presented with fresh challenges from ever more complex applications, the obligation everywhere is to provide maximum safety. Our BETAflam products meet the key international regulations and standards in both structural and civil engineering. We are convinced that the trend towards comprehensive safety will also be the focus of much attention in the future, and that we will make a crucial contribution in this regard with our high quality products
7 LEONI The Quality Connection 7 Safety from one source. Universal application with system integrity. Certificate No. 896 BETAflam cables according BETAflam cables according BETAflam cables according BETAfixss cable support to German VDE Standard to British Standard to Swiss Standard system with total circuit integrity in fire according to German DIN Standard Wires and cables for highest Single and Multicore cables Single and Multicore cables This support system is used in safety requirements with for highest safety require- for high safety requirements electrical cable installations circuit integrity in accordance ments, in accordance with in accordance with with system integrity. They with DIN VDE 0266 BS 6387 C.W.Z. SEV TP 20B/3C. also ensure fire resistant fixing of cables laid in the area VDE approval and LPCB approval and ElectroSuisse approval between floors as well as F30 surveillance surveillance Fire resistant / retardant and F90 suspended ceilings. Fire resistant PSB Product Listing No flame propagation No flame propagation Scheme, SG System circuit integrity DIN 4102 part 12 / Cross-linked by irradiation Fire resistant / Circuit E30 ABP approval System circuit integrity to integrity Halogen and silicone free High quality materials DIN 4102 part 12, E30 - E90 No flame propagation Low smoke and gas Long laying distances Halogen and silicone free Cross-linked by irradiation emission Reduced cost of materials Low smoke and gas Halogen and silicone free In compliance with RoHS Short installation time emission Low smoke and gas directive One source for cables and In compliance with RoHS emission Operating temperature laying system directive In compliance with RoHS 90 C System circuit integrity Operating temperature directive 90 C Operating temperature 90 C and 110 C
8 BETAflam 8 Safety and Communication Cables BETAflam Safety and Communication Cables Overview FRT-MI / 1 kv LSOH FRT-MI 90 / Single Core / Single Insulated Page 10 FRT-MI 90 / Single Core / Double Insulated Page 13 FR-MI / 1 kv LSOH BS 6387 C.W.Z. FR-MI 90 / Single Core / Single Insulated Page 16 FR-MI 90 / Single Core / Double Insulated Page 19 FR-MI / 1 kv LSOH BS 6387 C.W.Z. FR-MI 110 / Single Core / Single Insulated Page 22 FR-MI 110 / Single Core / Double Insulated Page 25 FR-MI 110 armoured 0.6 / 1 kv LSOH BS 6387 C.W.Z. FR-MI 110 / Multicore / Steel Tape Armour (STA) Page 31 FR-MI 110 / Multicore / Steel Wire Armour (SWA) Page 34 FR-MI / 500 V LSOH BS 6387 C.W.Z. FR-MI 110 Comms Cables Page
9 Safety and Communication Cables 9 BETAflam FR-MI 110 / Multicore Page
10 BETAflam 10 Safety and Communication Cables FRT-MI 90 / Single Core / Single Insulated BETAflam Fire Retardant Cores & Cables, 0.6 /1 kv, LSOH Advantages Halogen and silicone free Operating temperature 90 C In compliance with RoHS directive Mineral filled fire resistant materials Space saving due to small outer diameter Easy to handle and economical to install Application Use as replacement for conventional PVC wiring to reduce hazardous gas emission and avoid secondary damage in the event of fire. Construction Conductor: Bare annealed copper, acc. IEC class 2 Insulation: BETAflam mineral copolymer Core identification: Red, Black or Green/Yellow (other colours on request) Technical specification Rated voltage: U 0 /U 0,6 / 1 kv Test voltage: 3,5 kv / 50 Hz Temperature range: Operation temperature from 30 C to + 90 C Laying temperature from 5 C to + 70 C Short circuit temperature C (temperature peak 5 s) Bending radius: During laying > 15 outer Fixed installed > 10 outer Laying conditions: For electrical installation in control cabinets, switchboards or other closed cable wiring systems. Material properties Halogen free: IEC ; BS EN ; VDE No corrosive gases: IEC ; BS EN ; VDE No toxic gases: NES ; NF C20-454; BS EN Low smoke density: IEC & -2; BS EN ; VDE & -2 Fire performance Flame retardant: IEC ; BS EN ; VDE No flame propagation: IEC ; EN ; VDE &
11 BETAflam Fire Retardant Cores & Cables, 0.6 /1 kv, LSOH Safety and Communication Cables 11 BETAflam Cross section Part no. Core colour Conductor stranding thickness insulation diameter core Approx. weight Current Rating 1 AC Voltage Drop Fire Load 1 phase 2 3 phase 3 1 phase system 3 phase system mm² LSA n mm mm mm kg / km A A mv / Am mv / Am kwh / m red black g/y red black g/y red black g/y red black g/y red black g/y red black g/y red black g/y red black g/y red black g/y red black g/y red black g/y red black g/y red black g/y red black g/y red black g/y = On request g/y = Green/Yellow 1 AC circuit, max. conductor temperature 90 C 2 Free in air, spaced 3 Open tray, touching
12 BETAflam 12 Safety and Communication Cables BETAflam Fire Retardant Cores & Cables, 0.6 /1 kv, LSOH Cross section Part no. Core colour Conductor stranding thickness insulation diameter core Approx. weight Current Rating 1 AC Voltage Drop Fire Load 1 phase 2 3 phase 3 1 phase system 3 phase system mm² LSA n mm mm mm kg / km A A mv / Am mv / Am kwh / m 300 red black g/y red black g/y red black g/y red black g/y = On request g/y = Green/Yellow 1 AC circuit, max. conductor temperature 90 C 2 Free in air, spaced 3 Open tray, touching
13 Safety and Communication Cables 13 BETAflam FRT-MI 90 / Single Core / Double Insulated BETAflam Fire Retardant Cores & Cables, 0.6 /1 kv, LSOH Advantages Halogen and silicone free Operating temperature 90 C In compliance with RoHS directive Mineral filled fire resistant materials Space saving due to small outer diameter Easy to handle and economical to install Application Use as replacement for conventional PVC wiring to reduce hazardous gas emission and avoid secondary damage in the event of fire. Construction Conductor: Bare annealed copper, acc. IEC class 2 Insulation: BETAflam mineral copolymer Core identification: Black, White or Green-Yellow (other colours on request) Sheath: BETAflam mineral copolymer, Orange (Black on request) Technical specification Rated voltage: U 0 /U 0.6 / 1 kv Test voltage: 3.5 kv / 50 Hz Temperature range: Operation temperature from 30 C to + 90 C Laying temperature from 5 C to + 70 C Short circuit temperature C (temperature peak 5 s) Bending radius: During laying > 15 outer Fixed installed > 10 outer Laying conditions: For fixed installation indoor, in air, trays or dry tubes/ducts. Outdoor laying only when protected from direct sunlight and other external impacts. Material properties Halogen free: IEC ; BS EN ; VDE No corrosive gases: IEC ; BS EN ; VDE No toxic gases: NES ; NF C20-454; BS EN Low smoke density: IEC & -2; BS EN ; VDE & -2 Fire performance Flame retardant: IEC ; BS EN ; VDE No flame propagation: IEC ; EN ; VDE &
14 BETAflam 14 Safety and Communication Cables BETAflam Fire Retardant Cores & Cables, 0.6 /1 kv, LSOH Cross section Part no. Core colour Conductor stranding thickness insulation diameter core thickness sheath Approx. diameter weight cable Current Rating 1 AC Voltage Drop Fire Load 1 phase 2 3 phase 3 1 phase system 3 phase system mm² LSA n mm mm mm mm mm kg / km A A mv / Am mv / Am kwh / m 1.5 white black g/y white black g/y white black g/y white black g/y white black g/y white black g/y white black g/y white black g/y white black g/y white black g/y white black g/y white black g/y white black g/y white black g/y white black g/y = On request g/y = Green/Yellow 1 AC circuit, max. conductor temperature 90 C 2 Free in air, spaced 3 Open tray, touching
15 BETAflam Fire Retardant Cores & Cables, 0.6 /1 kv, LSOH Safety and Communication Cables 15 BETAflam Cross section Part no. Core colour Conductor stranding thickness insulation diameter core thickness sheath Approx. diameter weight cable Current Rating 1 AC Voltage Drop Fire Load 1 phase 2 3 phase 3 1 phase system 3 phase system mm² LSA n mm mm mm mm mm kg / km A A mv / Am mv / Am kwh / m 300 white black g/y white black g/y white black g/y white black g/y = On request g/y = Green/Yellow 1 AC circuit, max. conductor temperature 90 C 2 Free in air, spaced 3 Open tray, touching
16 BETAflam 16 Safety and Communication Cables FR-MI 90 / Single Core / Single Insulated BETAflam Fire Resistant Safety Cables 0.6 /1 kv, acc. to BS 6387 C.W.Z., LSOH Advantages High safety standard: BS 6387 C.W.Z, fully tested by LPCB Halogen and silicone free Operating temperature 90 C In compliance with RoHS directive Mineral filled fire resistant materials Space saving installation due to small outer diameter Application Single cores for use in cable wiring systems with improved fire performance and circuit integrity. Use for: Fire Alarm circuits, Fire Detection circuits, Emergency signal / Control circuits, Fire fighting systems (water pumps), Smoke Exhaust Systems etc. Especially recommended in areas where human and animal live as well as valuable property are exposed to high risk in case of fire. Construction Conductor: Bare annealed copper, acc. IEC class 2 Flame barrier: MICA tape Insulation: BETAflam mineral copolymer Core identification: Red, Black or Green-Yellow (other colours on request) Material properties Halogen free: IEC ; BS EN ; VDE No corrosive gases: IEC ; BS EN ; VDE No toxic gases: NES ; NF C20-454; BS EN Low smoke density: IEC & -2; BS EN ; VDE & -2 Fire performance Flame retardant: IEC ; BS EN ; VDE No flame propagation: IEC ; EN ; VDE & -2-4 Circuit integrity: BS 6387 C.W.Z. / 20 mm IEC ; VDE Technical specification Rated voltage: U 0 /U 0.6 / 1 kv Test voltage: 4 kv / 50 Hz Temperature range: Operation temperature from 30 C to + 90 C Laying temperature from 5 C to + 70 C Short circuit temperature C (temperature peak 5 s) Bending radius: During laying > 10 outer Fixed installed > 6 outer Laying conditions: Use for electrical installations in control cabinets, switchboards, or other closed cable wiring systems
17 FR-MI 90 / Single Core / Double Insulated Safety and Communication Cables 17 BETAflam Cross section Part no. Core colour Conductor stranding thickness insulation diameter core Approx. weight Current Rating 1 AC Voltage Drop Fire Load 1 phase 2 3 phase 3 1 phase system 3 phase system mm² LSA n mm mm mm kg / km A A mv / Am mv / Am kwh / m red black g/y red black g/y red black g/y red black g/y red black g/y red black g/y red black g/y red black g/y red black g/y red black g/y red black g/y red black g/y red black g/y red black g/y red black g/y = On request g/y = Green/Yellow 1 AC circuit, max. conductor temperature 90 C 2 Free in air, spaced 3 Open tray, touching
18 BETAflam 18 Safety and Communication Cables FR-MI 90 / Single Core / Single Insulated Cross section Part no. Core colour Conductor stranding thickness insulation diameter core Approx. weight Current Rating 1 AC Voltage Drop Fire Load 1 phase 2 3 phase 3 1 phase system 3 phase system mm² LSA n mm mm mm kg / km A A mv / Am mv / Am kwh / m red black g/y red black g/y red black g/y red black g/y = On request g/y = Green/Yellow 1 AC circuit, max. conductor temperature 90 C 2 Free in air, spaced 3 Open tray, touching
19 Safety and Communication Cables 19 BETAflam FR-MI 90 / Single Core / Double Insulated BETAflam Fire Resistant Safety Cables 0.6 /1 kv, acc. to BS 6387 C.W.Z., LSOH Advantages High safety standard: BS 6387 C.W.Z, fully tested by LPCB Halogen and silicone free Operating temperature 90 C In compliance with RoHS directive Mineral filled fire resistant materials Application Power cable 0.6 / 1 kv for fixed installation in cable systems with improved fire performance and circuit integrity. Use for: Fire Alarm circuits, Fire Detection circuits, Emergency signal / Control circuits, Fire fighting systems (water pumps), Smoke Exhaust Systems etc. Especially recommended in areas where human and animal live as well as valuable property are exposed to high risk in case of fire. Construction Conductor: Bare annealed copper, acc. IEC class 2 Flame barrier: MICA tape Insulation: BETAflam mineral copolymer Core identification: White, Black or Green-Yellow (other colours on request) Sheath: BETAflam mineral copolymer, Orange Technical specification Rated voltage: U 0 /U 0.6 / 1 kv Test voltage: 4 kv / 50 Hz Temperature range: Operation temperature from 30 C to + 90 C Laying temperature from 5 C to + 70 C Short circuit temperature C (temperature peak 5 s) Bending radius: During laying > 10 outer Fixed installed > 6 outer Laying conditions: For fixed installation indoor, in air, trays or dry tubes/ducts. Outdoor laying only when protected from direct sunlight and other external impacts. Material properties Halogen free: IEC ; BS EN ; VDE No corrosive gases: IEC ; BS EN ; VDE No toxic gases: NES ; NF C20-454; BS EN Low smoke density: IEC & -2; BS EN ; VDE & -2 Fire performance Flame retardant: IEC ; BS EN ; VDE No flame propagation: IEC ; EN ; VDE & -2-4 Circuit integrity: BS 6387 C.W.Z. / 20 mm IEC ; VDE
20 BETAflam 20 Safety and Communication Cables FR-MI 90 / Single Core / Double Insulated Cross section Part no. Core colour Conductor stranding thickness insulation diameter core thickness sheath diameter cable Approx. weight Current Rating 1 AC Voltage Drop Fire Load 1 phase 2 3 phase 3 1 phase system 3 phase system mm² LSA n mm mm mm mm mm kg / km A A mv / Am mv / Am kwh / m 1.5 white black g/y white black g/y white black g/y white black g/y white black g/y white black g/y white black g/y white black g/y white black g/y white black g/y white black g/y white black g/y white black g/y white black g/y white black g/y = On request g/y = Green/Yellow 1 AC circuit, max. conductor temperature 90 C 2 Free in air, spaced 3 Open tray, touching
21 FR-MI 90 / Single Core / Double Insulated Safety and Communication Cables 21 BETAflam Cross section Part no. Core colour Conductor stranding thickness insulation diameter core thickness sheath diameter cable Approx. weight Current Rating 1 AC Voltage Drop Fire Load 1 phase 2 3 phase 3 1 phase system 3 phase system mm² LSA n mm mm mm mm mm kg / km A A mv / Am mv / Am kwh / m 300 white black g/y white black g/y white black g/y white black g/y = On request g/y = Green/Yellow 1 AC circuit, max. conductor temperature 90 C 2 Free in air, spaced 3 Open tray, touching
22 BETAflam 22 Safety and Communication Cables FR-MI 110 / Single Core / Single Insulated BETAflam Fire Resistant Safety Cables 0.6 /1 kv, acc. to BS 6387 C.W.Z., LSOH Advantages High safety standard: BS 6387 C.W.Z, fully tested by LPCB Halogen and silicone free Operating temperature 110 C In compliance with RoHS directive Mineral filled fire resistant materials Space saving installation due to small outer diameter Application Single cores for use in cable wiring systems with improved fire performance and circuit integrity. For use: Fire Alarm circuits, Fire Detection circuits, Emergency signal / Control circuits, Fire fighting systems (water pumps), Smoke Exhaust Systems etc. Especially recommended in areas where human and animal live as well as valuable property are exposed to high risk in case of fire. Construction Conductor: Bare annealed copper, acc. IEC class 2 Flame barrier: MICA tape Insulation: BETAflam mineral copolymer, cross-linked (other colours on request) Core identification: Red, Black or Green-Yellow (other colours on request) Technical specification Rated voltage: U 0 /U 0.6 / 1 kv Test voltage: 4 kv / 50 Hz Temperature range: Operation temperature from 30 C to C Laying temperature from 5 C to + 70 C Short circuit temperature C (temperature peak 5 s) Bending radius: During laying > 10 outer Fixed installed > 6 outer Laying conditions: Use for electrical installations in control cabinets, switchboards, or other closed cable wiring systems Material properties Halogen free: IEC ; BS EN ; VDE No corrosive gases: IEC ; BS EN ; VDE No toxic gases: NES ; NF C20-454; BS EN Low smoke density: IEC & -2; BS EN ; VDE & -2 Fire performance Flame retardant: IEC ; BS EN ; VDE No flame propagation: IEC ; EN ; VDE & -2-4 Circuit integrity: BS 6387 C.W.Z. / 20 mm IEC ; VDE
23 FR-MI 110 / Single Core / Single Insulated Safety and Communication Cables 23 BETAflam Cross section Part no. Core colour Conductor stranding thickness insulation diameter core Approx. weight Current Rating 1 AC Voltage Drop Fire Load 1 phase 2 3 phase 3 1 phase system 3 phase system mm² LSA n mm mm mm kg / km A A mv / Am mv / Am kwh / m red brown black blue g/y red brown black blue g/y red brown black g/y red black g/y red black g/y red black g/y red black g/y red black g/y red black g/y red black g/y red black g/y red black g/y red black g/y red black g/y = On request g/y = Green/Yellow 1 AC circuit, max. conductor temperature 90 C 2 Free in air, spaced 3 Open tray, touching
24 BETAflam 24 Safety and Communication Cables FR-MI 110 / Single Core / Single Insulated Cross section Part no. LSA Core colour Conductor stranding thickness insulation diameter core Approx. weight Current Rating 1 AC Voltage Drop Fire Load 1 phase 2 3 phase 3 1 phase system 3 phase system mm² n mm mm mm kg / km A A mv / Am mv / Am kwh / m red black g/y red black g/y red black g/y red black g/y red black g/y = On request g/y = Green/Yellow 1 AC circuit, max. conductor temperature 90 C 2 Free in air, spaced 3 Open tray, touching
25 Safety and Communication Cables 25 BETAflam FR-MI 110 / Single Core / Double Insulated BETAflam Fire Resistant Safety Cables 0.6 /1 kv, acc. to BS 6387 C.W.Z., LSOH Advantages High safety standard: BS 6387 C.W.Z, fully tested by LPCB Halogen and silicone free Operating temperature 110 C In compliance with RoHS directive Mineral filled fire resistant materials Space saving installation due to small outer diameter Application Power cable 0.6 / 1 kv for fixed installation in cable systems with improved fire performance and circuit integrity. Use for: Fire Alarm circuits, Fire Detection circuits, Emergency signal / Control circuits, Fire fighting systems (water pumps), Smoke Exhaust Systems etc. Especially recommended in areas where human and animal live as well as valuable property are exposed to high risk in case of fire. Construction Conductor: Bare annealed copper, acc. IEC class 2 Flame barrier: MICA tape Insulation: BETAflam mineral copolymer, cross-linked Core identification: White, Black or Green-Yellow (other colours on request) Sheath: BETAflam mineral copolymer, Orange (other colours on request) Technical specification Rated voltage: U 0 /U 0.6 / 1 kv Test voltage: 4 kv / 50 Hz Temperature range: Operation temperature from 30 C to C Laying temperature from 5 C to + 70 C Short circuit temperature C (temperature peak 5 s) Bending radius: During laying > 10 outer Fixed installed > 6 outer Laying conditions: For fixed installation indoor, in air, trays ore dry tubes/ducts. Outdoor laying only when protected from direct sunlight and other external impacts. Material properties Halogen free: IEC ; BS EN ; VDE No corrosive gases: IEC ; BS EN ; VDE No toxic gases: NES ; NF C20-454; BS EN Low smoke density: IEC & -2; BS EN ; VDE & -2 Fire performance Flame retardant: IEC ; BS EN ; VDE No flame propagation: IEC ; EN ; VDE & -2-4 Circuit integrity: BS 6387 C.W.Z. / 20 mm IEC ; VDE
26 BETAflam 26 Safety and Communication Cables FR-MI 110 / Single Core / Double Insulated Cross section Part no. Core colour Conductor stranding thickness insulation diameter core thickness sheath diameter cable Approx. weight Current Rating 1 AC Voltage Drop Fire Load 1 phase 2 3 phase 3 1 phase system 3 phase system mm² LSA n mm mm mm mm mm kg / km A A mv / Am mv / Am kwh / m white black g/y white black g/y white black g/y white black g/y white black g/y white black g/y white black g/y white black g/y white black g/y white black g/y white black g/y white black g/y white black g/y white black g/y white black g/y white black g/y = On request g/y = Green/Yellow 1 AC circuit, max. conductor temperature 90 C 2 Free in air, spaced 3 Open tray, touching
27 FR-MI 110 / Single Core / Double Insulated Safety and Communication Cables 27 BETAflam Cross section Part no. Core colour Conductor stranding thickness insulation diameter core thickness sheath diameter cable Approx. weight Current Rating 1 AC Voltage Drop Fire Load 1 phase 2 3 phase 3 1 phase system 3 phase system mm² LSA n mm mm mm mm mm kg / km A A mv / Am mv / Am kwh / m 400 white black g/y white black g/y white black g/y = On request g/y = Green/Yellow 1 AC circuit, max. conductor temperature 90 C 2 Free in air, spaced 3 Open tray, touching
28 BETAflam 28 Safety and Communication Cables FR-MI 110 / Multicore BETAflam Fire Resistant Safety Cables 0.6 /1 kv, acc. to BS 6387 C.W.Z., LSOH Advantages High safety standard: BS 6387 C.W.Z, fully tested by LPCB Halogen and silicone free Operating temperature up to +110 C In compliance with RoHS directive Application Multicore Power Cable 0.6 /1 kv for fixed installation in cable systems with improved fire performance and circuit integrity. Use for: Fire Alarm circuits, Fire Detection circuits, Emergency signal / Control circuits, Fire fighting systems (water pumps), Smoke Exhaust Systems etc. Especially recommended in areas where human and animal live as well as valuable property are exposed to risk in case of fire. Construction Conductor: Bare annealed copper, acc. IEC class 2 Flame barrier: MICA tape Insulation: BETAflam mineral copolymer, cross-linked Inner covering: Glass fiber tape Core identification: See technical information (other colours on request) Sheath: BETAflam mineral copolymer, orange (other colours on request) Bending radius: During laying > 12 outer Fixed installed > 7 outer Laying conditions: For fixed indoor installation in trays, ladders, ducts or concretes. Laying in earth or water only in water-proof dry tubes/ducts. Outdoor use only when protected from direct sunlight and other external impacts. Special designs with additional UV-, anti termite-, anti rodentresistance are available on request. Material properties Halogen free: IEC ; BS EN ; VDE No corrosive gases: IEC ; BS EN ; VDE No toxic gases: NES ; NF C20-454; BS EN Low smoke density: IEC & -2; BS EN ; VDE & -2 Technical specification Rated voltage: U 0 /U 0.6 / 1 kv Test voltage: 4 kv / 50 Hz Temperature range: Operation temperature from 30 C to C Laying temperature from 5 C to + 70 C Short circuit temperature C (temperature peak 5 s) Fire performance Flame retardant: IEC ; BS EN ; VDE No flame propagation: IEC ; EN ; VDE & -2-4 Circuit integrity: BS 6387 C.W.Z. / 20 mm IEC ; VDE
29 FR-MI 110 / Multicore Safety and Communication Cables 29 BETAflam Cross section Part no. Number of cores Conductor stranding thickness insulation diameter core thickness sheath diameter cable Approx. weight Current Rating 1 AC Voltage Drop Fire Load 1 phase 2 3 phase 2 1 phase 2 3 phase 2 mm² LSA n mm mm mm mm mm kg / km A A mv / Am mv / Am kwh / m C C+E C C+E C C+E C C C C C C C C C C C+E C C+E C C+E C C C C C C C C C+E C C+E C C+E C C C C+E C C+E C C+E C C+E C C+E C C+E C+E C C+E C C+E = On request 1 AC circuit, max. conductor temperature 90 C 2 Open tray, touching
30 BETAflam 30 Safety and Communication Cables FR-MI 110 / Multicore Cross section Part no. Number of cores Conductor stranding thickness insulation diameter core thickness sheath diameter cable Approx. weight Current Rating 1 AC Voltage Drop Fire Load 1 phase 2 3 phase 2 1 phase 2 3 phase 2 mm² LSA n mm mm mm mm mm kg / km A A mv / Am mv / Am kwh / m C+E C C+E C C+E C+E C C+E C C+E C+E C C+E C C+E C+E C C+E C C+E C+E C C+E C C+E C+E C C+E C C+E C C+E C+E C C+E C+E C C+E C+E C C+E C+E C C+E = On request 1 AC circuit, max. conductor temperature 90 C 2 Open tray, touching
31 FR-MI 110 / Multicore / Steel Tape Armour (STA) BETAflam Fire Resistant Safety Cables 0.6 /1 kv, acc. to BS 6387 C.W.Z., LSOH Safety and Communication Cables 31 BETAflam Advantages High safety standard: BS 6387 C.W.Z, fully tested by LPCB Halogen and silicone free Operating temperature up to +110 C In compliance with RoHS directive Robust cable with increased resistance to mechanical impact Application Armoured Power Cable 0.6 /1 kv with improved fire performance and circuit integrity. Suitable for fixed installation in areas with increased demand to mechanical stress. Typical applications: Fire Alarm circuits, Fire Detection circuits, Emergency signal / Control circuits, Fire fighting systems (water pumps), Smoke Exhaust Systems etc. Especially recommended in areas where human and animal live as well as valuable property are exposed to risk in case of fire. Construction Conductor: Bare annealed copper, acc. IEC class 2 Flame barrier: MICA tape Insulation: BETAflam mineral copolymer, cross-linked Inner covering: Glass fiber tape Inner sheath: BETAflam mineral copolymer Armouring: Steel tape armour (STA) Core identification: See technical information (other colours on request) Sheath: BETAflam mineral copolymer, orange (other colours on request) Technical specification Rated voltage: U 0 /U 0.6 / 1 kv Test voltage: 4 kv / 50 Hz Temperature range: Operation temperature from 30 C to C Laying temperature from 5 C to + 70 C Short circuit temperature C (temperature peak 5 s) Bending radius: During laying > 15 outer Fixed installed > 9 outer Laying conditions: For fixed indoor installation in trays, ladders, ducts or concretes. Direct laying in earth or water only in water-proof dry tubes/ducts. Outdoor use if protected from direct sunlight only. Special designs with additional UV or anti termite-resistance are available on request. Material properties Halogen free: IEC ; BS EN ; VDE No corrosive gases: IEC ; BS EN ; VDE No toxic gases: NES ; NF C20-454; BS EN Low smoke density: IEC & -2; BS EN ; VDE & -2 Fire performance Flame retardant: IEC ; BS EN ; VDE No flame propagation: IEC ; EN ; VDE & -2-4 Circuit integrity: BS 6387 C.W.Z. / 20 mm IEC ; VDE
32 BETAflam 32 Safety and Communication Cables FR-MI 110 / Multicore / Steel Tape Armour (STA) Cross section Part no. Number of cores Conductor stranding diameter under STA diameter over STA thickness sheath diameter cable Approx. weight Current Rating 1 AC Voltage Drop Fire Load 1 phase 2 3 phase 2 1 phase 2 3 phase 2 mm² LSA n mm mm mm mm mm kg / km A A mv / Am mv / Am kwh / m C C+E C C+E C C+E C+E C+E C+E C+E C+E C+E C+E C+E C C+E C C+E C C+E C+E C+E C+E C+E C C+E C C+E C C+E C+E C C+E C C+E C C+E C C+E C C+E C C+E C+E C+E C C+E C+E C+E C C+E C+E C+E C C+E = On request 1 AC circuit, max. conductor temperature 90 C 2 Open tray, touching
33 FR-MI 110 / Multicore / Steel Tape Armour (STA) Safety and Communication Cables 33 BETAflam Cross section Part no. Number of cores Conductor stranding diameter under STA diameter over STA thickness sheath diameter cable Approx. weight Current Rating 1 AC Voltage Drop Fire Load 1 phase 2 3 phase 2 1 phase 2 3 phase 2 mm² LSA n mm mm mm mm mm kg / km A A mv / Am mv / Am kwh / m 50 2C+E C+E C C+E C+E C+E C C+E C+E C+E C C+E C+E C+E C C+E C+E C C+E C+E C C+E C+E C C+E C+E C C+E C+E C = On request 1 AC circuit, max. conductor temperature 90 C 2 Open tray, touching
34 BETAflam 34 Safety and Communication Cables FR-MI 110 / Multicore / Steel Wire Armour (SWA) BETAflam Fire Resistant Safety Cables 0.6 /1 kv, acc. to BS 6387 C.W.Z., LSOH Advantages High safety standard: BS 6387 C.W.Z, fully tested by LPCB Halogen and silicone free Operating temperature up to C In compliance with RoHS directive Robust cable with increased resistance to mechanical impact Application Armoured Power Cable 0.6 / 1 kv with improved fire performance and circuit integrity. Suitable for fixed installation in areas with increased demand to mechanical stress. Typical applications: Fire Alarm circuits, Fire Detection circuits, Emergency signal / Control circuits, Fire fighting systems (water pumps), Smoke Exhaust Systems etc. Especially recommended in areas where human and animal live as well as valuable property are exposed to risk in case of fire. Construction Conductor: Bare annealed copper, acc. IEC class 2 Flame barrier: MICA tape Insulation: BETAflam mineral copolymer, cross-linked Inner covering: Glass fiber tape Inner sheath: BETAflam mineral copolymer Armouring: Steel wire armour (SWA) Core identification: See technical information (other colours on request) Sheath: BETAflam mineral copolymer, Orange (other colours on request) Technical specification Rated voltage: U 0 /U 0.6 / 1 kv Test voltage: 4 kv / 50 Hz Temperature range: Operation temperature from 30 C to C Laying temperature from 5 C to + 70 C Short circuit temperature C (temperature peak 5 s) Bending radius: During laying > 15 outer Fixed installed > 9 outer Laying conditions: For fixed indoor installation in trays, ladders, ducts or concretes. Direct laying in earth or water only in water-proof dry tubes/ducts. Outdoor use if protected from direct sunlight only. Special designs with additional UV or anti termite-resistance are available on request. Material properties Halogen free: IEC ; BS EN ; VDE No corrosive gases: IEC ; BS EN ; VDE No toxic gases: NES ; NF C20-454; BS EN Low smoke density: IEC & -2; BS EN ; VDE & -2 Fire performance Flame retardant: IEC ; BS EN ; VDE No flame propagation: IEC ; EN ; VDE & -2-4 Circuit integrity: BS 6387 C.W.Z. / 20 mm IEC ; VDE
35 FR-MI 110 / Multicore / Steel Wire Armour (SWA) Safety and Communication Cables 35 BETAflam Cross section Part no. Number of cores Conductor stranding diameter diameter under SWA over SWA thickness sheath diameter cable Approx. weight Current Rating 1 AC Voltage Drop Fire Load 1 phase 2 3 phase 2 1 phase 2 3 phase 2 mm² LSA n mm mm mm mm mm kg / km A A mv / Am mv / Am kwh / m C+E C C+E C C+E C+E C C+E C C+E C+E C C+E C C+E C+E C C+E C C+E C+E C+E C C+E C+E C C+E C C+E C+E C+E C C+E C+E C+E C C+E C C+E C C+E C+E C C+E C+E C C+E C+E C = On request 1 AC circuit, max. conductor temperature 90 C 2 Open tray, touching
36 BETAflam 36 Safety and Communication Cables FR-MI 110 / Multicore / Steel Wire Armour (SWA) Cross section Part no. Number of cores Conductor stranding diameter diameter under SWA over SWA thickness sheath diameter cable Approx. weight Current Rating 1 AC Voltage Drop Fire Load 1 phase 2 3 phase 2 1 phase 2 3 phase 2 mm² LSA n mm mm mm mm mm kg / km A A mv / Am mv / Am kwh / m 185 2C+E C+E C C+E C+E C C+E C+E C C+E C+E C = On request 1 AC circuit, max. conductor temperature 90 C 2 Open tray, touching
37 FR-MI 110 Comms Cables Shielded/Unshielded Twisted Pair (S/UTP) BETAflam Fire Resistant Comms Cables screened 300 / 500 V, acc. to BS 6387 C.W.Z. Safety and Communication Cables 37 BETAflam Advantages High safety standard: BS 6387 C.W.Z LPCB listed and certified Halogen and silicone free Operating temperature up to C In compliance with RoHS directive Mineral filled materials Application Shielded communication cable 300 / 500 V for fixed installation in cable systems with excellent fire performance and circuit integrity. For Fire Alarm Circuits, Fire Detection Circuits, Emergency Signal / Control Circuits, Fire Fighting Systems (water pumps) and Smoke Exhaust Systems etc. Especially recommended in areas where human and animal live as well as valuable property are exposed to risk in case of fire. Construction Conductors: Tinned annealed copper, acc. IEC class 2 Flame barrier: MICA tape Insulation: BETAflam mineral copolymer, cross linked Inner covering: Plastic tape Screening: Aluminium laminated foil with drain wire Sheath: BETAflam mineral copolymer Core identification: White cores with black number marking (other colours on request) Sheath colour: Red or Orange (other colours on request) Technical specification Rated voltage: U 0 /U 300 / 500 V Test voltage: 0.5 / 2 kv / 50 Hz (core-screen / core-core) Temperature range: Operation temperature from 30 C to C Laying temperature from 5 C to + 70 C Short circuit temperature C (temperature peak 5 s) Bending radius: During laying > 12 outer Fixed installed > 8 outer Laying conditions: For fixed indoor installation in trays, ladders, ducts or concretes. Laying in earth or water only in water-proof dry tubes/ducts. Outdoor use only when protected from direct sunlight and other external impacts. Material properties Halogen free: IEC ; BS EN ; VDE No corrosive gases: IEC ; BS EN ; VDE No toxic gases: NF X Low smoke density: IEC & -2; BS EN (as certified) Fire performance Flame retardant: IEC ; BS EN ; VDE No flame propagation: IEC ; EN ; VDE Circuit integrity FE 180: IEC ; VDE Circuit integrity: BS 6387 C.W.Z. (as certified)
38 BETAflam 38 Safety and Communication Cables FR-MI 110 Comms Cables Cross section Part no. Sheath colour Number of pairs Conductor stranding thickness insulation diameter core thickness sheath diameter cable Approx. weight Fire Load mm² LSA n mm mm mm mm mm kg / km kwh / m red 1P (BK. WH) orange 1P orange 2P orange 3P orange 5P orange 7P orange 10P red 1P (BK. WH) red 1P orange 2P orange 3P orange 5P orange 7P orange 10P red 1P (BK. WH) red 1P orange 2P orange 3P orange 5P orange 7P orange 10P red 1P (BK. WH) red 1P orange 2P orange 3P orange 5P orange 7P orange 10P = On request P = Pair BK = Black WH = White
39 Safety and Communication Cables 39 BETAflam
40 40 BETAflam Safety Power and Communication Cables BETAflam Safety Power and Communication Cables Overview German DIN VDE cables, with circuit and system integrity E30, E60, E90, LSOH Swiss cables, with circuit integrity E30, LSOH Optimised fire protection properties Circuit and system integrity Halogen and silicone free No corrosive gases and low smoke density Irradiation crosslinked Universal use (N)HXH-J FE180 / E90 (N)HXH-J FE180 / E30 - E60 N2XH-J (N)HXH-J FE180 / E90 (N)HXH-J FE180 / E30 - E60 N2XCH (N)HXCH FE180 / E90 (N)HXH-J FE180 / E30 - E60 NHXMH-J (N)HXCH FE180 / E30 - E60 (N)HXCH FE180 / E30 - E60 JE-H(St)H FE180 / E30 - E90 J-H(St)H BMK red JE-H(St)H FE180 / E30 - E90 BMK JE-H(St)HRH FE180 / E30 - E90 BMK JE-H(St)H FE180 / E30 J-H(St)H grey FE180 / E30 FE5 FE
41 BETAfixss Laying System 41 BETAfixss Laying System Overview Certified cable laying system with system integrity in the event of fire Long laying distances Reduced cost of materials and installation Short fitting times High quality materials Cable and laying system from one source DIN 4102 part 12 tested and approved 3000 mm Mounting distance WSB X Span tray 20 kg/m, E30 / E mm Mounting distance KR 20 and KR 25 Cable rack 20 and 25 kg/m, E30 / E90 MB 20 and MB 25 Multi tray system 20 and 25 kg/m, E30 / E90 GK Mesh tray 10 kg/m, E30 / E90 STR Vertical riser 20 kg/rung, E30 / E mm Mounting distance ES und GSM Single clamp and Joint clamp 2.5 kg/clamp, E30 / E90 RES Tube laying 10 kg/m, E30 / E90 BAC U-clamp with System track 2.5 kg/clamp, E30 / E90 RBS Tube and clamp with System track 10 kg/m, E30/E mm Mounting distance ES und GSM Single clamp and Joint clamp 7.5 kg/clamp, E30 / E90 BAC U-clamp with System track 7.5 kg/clamp, E30 / E90 DWS Ceiling/wall hanger 7.5 kg/clamp, E30 / E90 Insta-Clic Cable holder and conduit 2-in-1 E30 / E mm Mounting distance F Single clamp E30 / E90 RF Plastic tube halogen free with F-Single clamp, E30 / E90 Accessories
42 42 Flexible BETAtherm and BETAflam Cables Flexible BETAtherm and BETAflam Cables Overview LSOH Universal industrial use Single Core with increased environmental compatibility Flame retardant No flame propagation BETAtherm 90 1 mm² SO 05Z1- K, 300 / 500 V 1.5 mm² SO 07Z1- K, 450 / 750 V BETAtherm mm² H05Z - K, 300 / 500 V 1.5 mm² H07Z - K, 450 / 750 V BETAtherm mm² SO 05Z- K, 300 / 500 V 1.5 mm² SO 07Z - K, 450 / 750 V BETAtherm 145 UL / CSA UL 3266 / CSA AWM I A/B 125 C / 300 V UL 3271 / CSA AWM I A/B 125 C / 600 V Single Core with maximum resistance to temperature Flame retardant BETAtherm mm² 300 / 500 V 1.5 mm² 450 / 750 V BETAtherm 155 UL / CSA UL 3289 / CSA CL 1503 / 600 V BETAtherm smart-f 1 mm² 300 / 500 V 1.5 mm² 450 / 750 V Multicore with increased environmental compatibility Flame retardant No flame propagation BETAflam 145 flex 450 / 750 V, temperature resistant BETAflam CHEMAflex 450 / 750 V, oil and chemical resistant BETAflam 145 C-flex 450 / 750 V, temperature resistant BETAflam CHEMA C-flex 600 / 1000 V, oil and chemical resistant BETAflam CHEMAflex R 300 / 500 V, oil and chemical resistant BETAflam CHEMA C-flex R 300 / 500 V, oil and chemical resistant Shielded connection cable for motors EMC optimized With symmetrical conductor layout No flame propagation BETAdrive C-flex 600 / 1000 V
43 Flexible BETAtrans Cables 43 Flexible BETAtrans Cables Overview LSOH Rolling Stock applications Universal use Single Core with increased dielectric strength Temperature resistant 120 C Flame retardant BETAtrans 3 GKW 1.8 / 3 kv BETAtrans GKW R volume optimised 300 / 500 V BETAtrans 4 GKW-AXplus 1.8 / 3 kv BETAtrans 4 GKW-AXplus C-flex 1.8 / 3 kv BETAtrans 9 GKW-AXplus 3.6 / 6 kv BETAtrans 9 GKW-AXplus C-flex 3.6 / 6 kv Multicore Temperature resistant 120 C Flame retardant BETAtrans GKW flex R 300 / 500 V BETAtrans GKW C-flex R volume optimised 300 / 500 V BETAtrans 3 GKW flex 0.6 / 1 kv BETAtrans 3 GKW C-flex 0.6 / 1 kv Single Core Temperature resistant 120 C Flame resistant Insulation integrity Multicore Temperature resistant 120 C Flame resistant Insulation integrity BETAtrans 3 GKW FE180 flex 0.6 / 1 kv BETAtrans 3 GKW FE180 flex 0.6 / 1 kv BETAtrans 3 GKW FE180 C-flex 0.6 / 1 kv Single Core with increased dielectric strength Temperature resistant 120 C Flame resistant Insulation integrity BETAtrans 4 GKW-AXplus FE180 flex 1.8 / 3 kv
44 44 Technical information Current rating Single Core / Single Insulated Cables, Conductor temperature 90 C with copper conductors, ambient temperature 30 C Cross section Mode of laying i n tubes, on or in wall or in closed conduits Mode of laying free in air spaced Mode of laying on surface spaced Mode of laying Mode of laying on surface touching Open laying on perforated trays or in air 2 cores 3 cores 2 cores 2 cores 3 cores 2 cores 3 cores mm² A A A A A A A Valid for continuous operation. For operating conditions different from the above, corrective factors must be taken into account (multiple cables, other load factors, ambient temperatures or multicore cables). Conversion factors for grouping 2 / 3 cores 2 cores 3 cores 2 / 3 cores Number Factor Factor Factor Factor
45 Technical information 45 Single Core / Double Insulated Cables, Conductor temperature 90 C with copper conductors, ambient temperature 30 C Cross section Mode of laying In tubes, on or in wall or in closed conduits Mode of laying free in air spaced Mode of laying on surface spaced Mode of laying Mode of laying on surface touching Open laying on perforated trays or in air 2 cores 3 cores 2 cores 2 cores 3 cores 2 cores 3 cores mm² A A A A A A A Valid for continuous operation. For operating conditions different from the above, corrective factors must be taken into account (multiple cables, other load factors, ambient temperatures or multicore cables). Conversion factors for grouping 2 / 3 cores 2 cores 3 cores 2 / 3 cores Number Factor Factor Factor Factor
46 46 Technical information Multicore Cables, Conductor temperature 90 ºC with copper conductors, ambient temperature 30 ºC (Number of energized cores 2 / 3) Cross section Mode of laying In tubes, on or in wall or in closed conduits Mode of laying Clipped direct or laid in open troughs or ducts Mode of laying Open laying on perforated trays or in air mm² A A A Valid for continuous operation. For operating conditions different from the above, corrective factors must be taken into account (multiple cables, other load factors, ambient temperatures or multicore cables). Conversion factors for grouping: Touching Number Factor Factor Factor Conversion factors for grouping: Spaced 1 Number Factor Factor Factor
47 Technical information 47 Conversion factors Ambient air temperature 30 C / Free in air / Conductor temperature 90 C 0 C 5 C 10 C 15 C 20 C 25 C 30 C 35 C 40 C 45 C 50 C 55 C 60 C Factor Factor Factor Factor Factor Factor Factor Factor Factor Factor Factor Factor Factor Conversion factors Duct in soil / Ambient soil temperature 20 C / depth of laying 0.5 m / Conductor temperature 90 C 0 C 5 C 10 C 15 C 20 C 25 C 30 C 35 C 40 C 45 C 50 C 55 C 60 C Factor Factor Factor Factor Factor Factor Factor Factor Factor Factor Factor Factor Factor Conversion factors Conductor temperature 90 C 40 C 50 C 60 C 70 C 80 C 90 C 100 C 110 C 120 C Factor Factor Factor Factor Factor Factor Factor Factor Factor
48 48 Technical information Core identification Hong Kong Colour Code current Core numbers Core function Without Green/Yellow core With Green/Yellow core 1 1C Red, Yellow, Blue, Black Green/Yellow 2 2C Black, Red 3 2C+E Black, Red, Green/Yellow 3C Red, Blue, Yellow 4 3C+E Red, Blue, Yellow, Green/Yellow 4C Black, Red, Blue, Yellow 5 4C+E Black, Red, Blue, Yellow, Green/Yellow 5C White, numbered from inside to outside 6 C see footnote 1 C+E see footnote 1 Core Colours: Phase: Red, Yellow, White, Blue Neutral: Black Earth: Green/Yellow 1 With 6 or more conductors the phase cores are of white colour and black numbering, numbering sequence from the inside to the outside. The earth conductor is always the last and the neutral conductor the second last core of the outer layer. The numbering sequence of the stranded conductors shall be the same at any cut end of the cable. European Harmonised Colour Code DIN VDE ; CENELEC HD 308 S2; BS 7671:2001 (on request) Core numbers Core function Without Green/Yellow core With Green/Yellow core 1 1C Black Green/Yellow 2 2C Blue, Brown 3 2C+E Green/Yellow, Blue, Brown 3C Brown, Black, Grey 4 3C+E Green/Yellow, Blue, Brown, Black 3C+E Green/Yellow, Brown, Black, Grey 4C Blue, Brown, Black, Grey 5 4C+E Green/Yellow, Blue, Brown, Black, Grey 5C Blue, Brown, Black, Grey, Black 6 C see footnote 2 C+E see footnote 2 Core Colours: Phase: Brown, Black, Grey Neutral: Blue Earth: Green/Yellow 2 With 6 or more conductors the phase cores are of Black colour and White numbering, sequence from the inside to the outside. The earth conductor is always the last and the neutral conductor the second last core of the outer layer. The numbering sequence of the stranded conductors shall be the same at any cut end of the cable
49 Fire performance Halogen free Degree of acidity of combustion gases Technical information 49 The halogens are the elements of the 7th group in the Periodic Table of Elements: Chlorine (Cl) Fluorine (F) Bromine (Br) Iodine (I) Halogen free cables must be free of chlorine, fluorine and bromine (PVC cables contain halogen, PVC = Polyvinylchloride). The halogens are an integrated component of many acids HCl = Salt acid (hydrochloric acid) HF = Hydrogenfluorid HBr = Hydrogenbromid The most popular plastic containing halogens is PVC (polyvinylchloride). In case of fire or at high temperature PVC starts to degradate. Hydrochloric acid and other fission products are generated and leads to extremely aggressive corrosion. Therefore the current trend is to replace the halogen containing plastics with halogen free ones. For instance PVC is currently being replaced at a large scale with polyolefin i.e. polyethylene. Thanks to halogen free cables the formation of corrosive and toxic gases can be prevented. Test procedures 1000 mg of the testing material must be hold at one termination of an pre-annealed copper wire in a gas flame. The material is considered to be halogen free if no green to blue-green flame discolouration occurs. The chlorine and the bromine would cause such a discolouration, however the existence of fluorine cannot be proven like that. Corrosive gases act with moisture to produce aggressive acids which corrode metal parts and cause extensive long-term damage, even though the fire damage may only be limited; this is because corrosive gases often spread throughout a building through the ventilation system or withing whole installations. The damage may not be limited to the area immediately affected by the fire. Electronic units and electronic contacts are particularly vulnerable, as are free-standing or concrete enclosed steel constructions. Test procedures 1000 mg insulation material is burned in a combustion furnace at 935 C with pre-defined air supply for over 30 minutes. By means of two gas washing containers, held in the airflow the conductivity and the ph-value are measured. Like that even small quantities of halogen containing substances can be detected and proven. The test is considered to be passed when the ph-value > 4.3 the conductivity < 10 µs/mm Test standards IEC , EN IEC , EN Combustion furnace Test standards IEC , EN Air supply Testing material Gas washing containers Testing material IEC 60754, EN IEC , EN Combustion furnace Air supply Testing material Gas washing containers Temperature sensor
50 50 Technical information Fire performance Smoke density Flame retardant The formation of smoke has several un pleasant consequences. On one hand it considerably lowers the visibility in a fire event, thus impeding the people trapped inside closed rooms escape of and the efforts of the firemen to carry on their rescue and fire fighting actions. On the other hand it produces smoke poisoning because of the carbon monoxide. Regarding the formation of the combustion gases the PVC comes off quite badly. Flame retardant cables are cables which, when installed as a single cable, although ignitable on exposure to flame source, will greatly reduce flame spread and selfextinguish once the flame source is removed. However in a vertical cable bundle, e.g. in vertical risers, fire can spread along the cables (chimney effect). In order to avoid this danger, the so called «no flame propagating» cables should be used. Test procedures The density of smoke emission can be determined by measuring of the light penetrability. Cable samples are lit with alcohol in a test chamber (cubical with an edge length of 3 m). The so formed smoke is uniformly spread by a ventilator and influences the light measuring section. The test is considered to be passed when the following light penetrability is reached: Dangerous level Requirements HL 1 HL 2 and HL 3 60 % HL 4 70 % Test standards IEC 61034, EN IEC , EN Test procedures This test procedure describes the minimum requirements for flame retardant cables and it is valid for lead wires or on single cables only. A lead wire or a cable is being aflamed with a propane-air-burner (1 kw flame). Test duration > 75 = 60 s = 120 s = 240 s = 480 s The burning cable should self-extinguish as soon as the fire source has been removed. The fire damage may not be higher than 60 cm. The test is considered to be passed if the sample has not burned and the damage (carbonisation) has not reached any of the terminations of the sample (> 50 mm). Test standards IEC , EN Convection shield Light receiver 3000 Ventilator Def.-St (ehemals NES 711) Convection shield Light receiver Ventilator
51 Fire performance No flame propagation Technical information Circuit integrity under fire 51 No flame propagating cables are those cables which can be ignited by a flame source, however they do not allow the fire to spread even if the cable bundle is placed vertically; they are self extinguishing once the fire source is removed. Test procedures This test simulates the chimney effect in vertical cable installations. In a standardized cabinet the cable bundle is kept in a burner fire for minutes (gas burner 75 ± 5 MJ/h). Thereby the temperature is kept constant to 750 C. Depending on the volume of the non-metal (combustible) materials per running meter it can be differentiated in the categories A F/R, A, B, C und D as follows. Category A F/R A B C D Liter (dm³) of insulation material per 1 m sample Aflame time (min) The circuit integrity indicates, how long a free cable retains its isolation in a fire without causing a short-circuit. According to its international standard, a cable is laid horizontally over a burner for three hours. The temperature is set at 800 C. The circuit integrity is designated with FE (e.g. FE180 = circuit integrity of 180 min): BETAflam FE180 / E30 Test procedures The sample is fastened at definited distances above the burner. The conductor is connected to a power source at nominal voltage via an 2 A fuse. The test is considered to be passed, if during the test no short circuit or circuit interruption occurs. Test standards DIN VDE IEC Apparatus 750 C IEC Cables rated up to 0.6 / 1.0 kv The cables must self-extinguish after removing the fire source. The fire may not have propagated any further than 2,5 m from the burner. With the cables of LEONI Studer AG this should reach no further than 50 to 60 cm. Test standards Category IEC EN VDE 0482 A F/R part A part B part C part D part Apparatus part ± R S T N, PE 1200 Cable 70 ± 10 Air
52 52 Technical information Fire performance Circuit integrity with mechanical shock System integrity Cables for emergency circuits up to 20 mm diameter are subject and tested to fire with mechanical shock during a survival time of maximum 90 minutes. Maintaining the functionality of cable installations in event of fire. The test involves the cable and the laying resp. fastening system. Test procedures A single cable is fastened to a test wall under conditions of minimum bending radii and is tested at a minimum test temperature of 830 C and impacts on the cable support. During the test no rupture of conductors shall appear and voltage must be maintained. For the purposes of the European Construction Products Directive the survival time serves to classify the cables into PH classes from PH15 to PH90. The test is considered to be passed, if during the test no short circuit occurred. Test standards DIN EN 50200, classes PH 15, 30, 60, 90 VDE 0482 part 1 IEC Apparatus 830 C IEC Fire with shock, up to 0.6 / 1.0 kv Test procedures The profiles are installed together with the fastening system in a testing oven with a minimum length of 3 m. The conductors are connected to a 400 V (for control cables 110 V) power source and fused with 2 A. The testing temperature is 850 C up to 1000 C. The test is considered to be passed, if during the test there is no Short circuit or circuit interruption in the cable system. The classification E30, E60, E90 bases on the least favourable result obtained on at least two identical specimens. The heat-induced increase in conductor resistance is not taken into account during the test. Test standard DIN 4102 part 12: E C to 900 C for 30 min E C to 970 C for 60 min E C to 1000 C for 90 min
53 Fire performance Resistance to fire alone Technical information Resistance to fire with water 53 When the cable sample is tested, no fuse shall be ruptured nor any lamp extinguished during the period of the test. When the cable sample is tested, no fuse shall be ruptured nor any lamp extinguished during the period of the test. Test procedures The cable is held horizontally by suitable clamps and adjusted to the metal support rings above the burner. Each conductor is connected to a transformer output with a 3 A fuse and adjusted to the rated voltage. The test is considered to be passed, if during the test no short circuit or circuit interruption occurs. Test procedures The cable is held horizontally by suitable clips above the burner. Each conductor is connected to a transformer output with a 3 A fuse and adjusted to the rated voltage. The test is considered to be passed, if during the test no short circuit or circuit interruption occurs. Test standard BS 6387:1994 Test A Test B Test C Test S 650 C for 3 h 750 C for 3 h 950 C for 3 h 950 C for 20 min Test standard BS 6387:1994 Test W 650 C for 30 min first 15 min burner only second 15 min burner with water sprinkler turned on R S T Cable Sprinkler water 350 N, PE
54 54 Technical information Fire performance Resistance to fire with mechanical shock When the cable sample is tested, no fuse shall be ruptured nor any lamp extinguished during the period of the test. Test procedures The cable is bent and mounted to the vertical wall using clips. Each conductor is connected to a transformer output with a 3 A fuse and adjusted to the rated voltage. The test is considered to be passed, if during the test no short circuit or circuit interruption occurs. Test standard BS 6387:1994 Test X Test Y Test Z 650 C for 15 min 750 C for 15 min 950 C for 15 min 900 Ø 25 D 6 D
55 Technical information 55 Summary of standards Requirements International IEC Europe CENELEC Germany VDE Halogen free IEC BS EN VDE NF C others No corrosive gases IEC BS EN VDE NF C No toxic gases BS EN NES ; NF C Low smoke density IEC and 2 BS EN and 2 VDE and 2 BS Armoured cables BS 7846 Flame retardant IEC BS EN VDE BS No flame propagation Flame spread IEC (AF/R) EN VDE IEC (A) EN VDE IEC (B) EN VDE IEC (C) EN VDE IEC (D) EN VDE Circuit integrity FE180 IEC VDE BS 6387 C With mechanical shock IEC EN / EN VDE BS 6387 Z With water sprinkler BS 6387 W System circuit integrity DIN 4102 part 12 E30, E60, E90 Limited Oxygen Index ASTM D 2863 EN ISO NES
56 56 Technical information General handling, storage and installation Instructions This information is intended to offer recommendations related to the installation of power cables, in order to prevent damage or deterioration, to ensure safety, functionality and protection from inappropriate handling before and during installation. Correct Load with flanges on edge and chock securely. Handling Upon receipt, and before acceptance of a shipment, all reels should be inspected for evidence of damage during shipment. This damage would include broken flanges, damaged wrapping or lagging, interlocked flanges, reels broken loose from their ties or blocking, check by defect or missing end caps etc. Any signs of such damage should immediately be reported to the carrier. Incorrect Winch Line Reel Tongs If the protective wrapping or lagging is removed to inspect for possible damage during shipment, it should be replaced prior to placing the reel into long term storage. Spacer Bar Correct Reels should be liftet with a shaft extending through both flanges Unloading of reels from the delivery truck must be accomplished in a manner that prevents the transfer equipment from coming into contact with either the cable itself or the protective covering over the reel. Incorrect A crane may be used to lift reels using a steel shaft of sufficient strength placed through the arbour holes. The shaft must be lifted using a spreader bar to prevent the lifting cable or chain from pressing against the reel flanges. The force exerted by improperly positioned slings has been known to break reel flanges, resulting in damaging the cable. Reels never should be dropped from the delivery vehicle to the ground. Never drop reels from trailer Correct Reels should be lowered using hydraulic gate, hoist or forklift LOWER CAREFULLY Lifting of specific cable lengths on the site shall respect the same handling procedure mentioned above, i.e. by using drums. Incorrect Inspect all reels. Reels laying flat should be refused or received subject to inspection
57 General handling, storage and installation Instructions Technical information 57 If a fork lift truck is used, the forks shall be placed at a 90 angle to the flanges, and must be long enough to make contact with both flanges. Under no circumstances should the forks directly touch the cable or protective covering. Incorrect Do not allow forks to touch cable or reel wrap. Incorrect Do not allow forks to touch cable or reel wrap. Incorrect Do not allow forks to touch cable or reel wrap. Incorrect Do not allow forks to touch cable or reel wrap. Correct This method OK for Low Voltage Cable ONLY. When a reel is rolled from one point to another, care shall be taken to ensure that the reel does not straddle objects such as rocks, pipes, or wooden blocks which could damage the cable or protective covering. Incorrect A reel should always be rolled in the direction indicated by arrows on the flange in order to avoid unintended uncoiling. Correct Special care shall be taken during uncoiling or unreeling cables since their performance is substantially influenced by the way in which they are handled. Reverse bending or twisting can cause internal damage which can adversely affect the lifetime of the cable. Incorrect The cable should never be pulled over the flange of a reel, or pulled off the side of a coil. The mechanical forces occurring due to torsion can seriously damage the cable or cable elements such as the armour, braid, shielding etc. Correct
58 58 Technical information General handling, storage and installation Instructions Storage Reels should be stored in an area reserved for this purpose. The location shall be accessible to forklifts and trucks, but apart from areas of constant traffic. Suitable barriers should be erected to prevent damage from moving equipment. Reels must be stored in an area where they cannot be damaged by falling objects, chemical spills including oil and grease, open flames or welding operations, and excessive heat. Whenever possible, reels should be stored indoors to provide maximum protection. If the cable must be stored outside, the reels should be placed on a hard, well-drained surface with an overhead protection or be covered with a suitable material such as canvas or opaque polyethylene to avoid prolonged exposure to sunlight or rain. If only a portion of the cable is used, the open end of the cable remaining on the reel should be re-sealed in a manner equivalent to the factory seal (with end caps) to prevent the entrance of moisture. After re-sealing, the cut end should be fixed to the inside edge of the reel flange to prevent the end from extending beyond the flanges during reel movement. Reels should always be stored with their flanges vertical. They shall not be stored on their sides or stacked one on top of another. Care should be taken that reels cannot roll into one another, so that the flange of one reel hits the surface of cable on another reel. If necessary, reel flanges should be chocked to prevent movement.storage of cable drums shall respect the environment temperature range as mentioned in the specific cable data sheets. Installation Minimum temperature during installation To avoid risk of damage during handling, the cable should be installed only when both the cable and ambient temperature are above + 5 C and precautions have been taken to maintain the cable above this temperature. Low temperatures create handling and pulling difficulties of varying degrees depending on cable construction and installation location. Laying Drums should be mounted in a manner that the cable is pulled from the top of the drum. Cable rollers are recommended to prevent the cable from touching the ground. Correct positioning of rollers is important to keep friction to a minimum. The cable should preferably be drawn to its final position in a continuous manner. During stops, the cable will settle between rollers and may cause high strain on men and machines during restarting. Whether the pulling is manual or with a winch, it is necessary for one man to be stationed at the drum with a plank of wood wedged against the flange of the drum so that over-running of the drum is prevented if the pulling stops. Otherwise, many loose turns can easily develop on the drum. In any case the maximum pulling load must be strictly observed. The pulling load shall be increased constantly up to the maximum allowed values without jerky movement. Under no circumstances should the bending radius be less than the minimum permissible limits. It is particularly important to have a generous bending radius when cables are to be pulled by a power winch, so as to keep within the maximum permissible pulling tension and to prevent the cable being flattened around bends or in cable laying systems (ducts, trays, etc.)
59 General handling, storage and installation Instructions Technical information 59 Installation parameters Recommended standard values for the minimum bending radius Type of cable Min. bending radius Cable factor Single core unarmoured 18 Single core armoured 20 Multicore unarmoured > 95 mm² 15 Multicore unarmoured > 120 mm² 18 Multicore armoured 20 Maximum permissible tensile load during installation Type of cable Formula Factor P N/mm² Single core unarmoured (Cu) σ A σ = 50 Single core unarmoured (Al) σ A σ = 30 Multicore unarmoured (Cu) σ A σ = 50 Multicore unarmoured (Al) σ A σ = 30 Single core steel wire armoured K d2 K = 9 Multicore steel wire armoured K d2 K = 9 Fire resistant cables with halogen free flame retardant outer sheath need to be handled with specific care during installation. While special additives are used in the formulation of their compounds to achieve the typical characteristics e.g.: Limited Oxygen Index, Low Smoke Density, No Acid Gas Release and Flame Retardancy, some of their mechanical properties are decreasing. When pulled on cable trays special attention is required to avoid scrubbing on any uneven or unusually rough surface. Rollers and bends should not have any sharpness which may damage the outer sheath. Note: Discrepancies with the above mentioned instructions require to be coordinated/clarified with the manufacturer. Particular attention should be paid to relevant local Safety Regulations, Technical Specifications and Environmental Prescriptions. Single core steel tape armoured K d2 K = 3 Multicore steel tape armoured K d2 K = 3 P = Pulling load in N σ = Maximum permissible tensile load in N/mm² A = Algebraic sum of conductor cross sections in mm² (without elements such as braid, shielding etc.) d = Overall cable diameter in mm K = Empirically calculated factor
60 60 Technical information Duration of system circuit integrity in the building laws The duration of the system circuit integrity depends on how long the supply of electrical services must continue in the event of a fire. National legislations in most countries provide requirements for safety systems which have to be met. Evacuation In many countries a duration of 30 minutes is considered sufficient for alarm and evacuation of people. Compliance with this requirement with regard to the systems (fire alarm systems, emergency lighting, passenger hoists, smoke exhaust, voice alarm and acoustic signalling, escape route signalling) can be achieved by means of a «Class E30» cable system. For special buildings like high-rise buildings, hospitals, shopping centres, tunnels, prisons, a duration of 60 to 90 minutes can also be adequate. In this case a «Class E60» or even «E90» cable system could be required (e.g. for the supply of lifts for in-patients etc.). Fire fighting Besides rescuing time for people extra time for the work of the fire brigades must be allocated. Mostly 90 minutes after the fire starts are regarded sufficient for fire fighting. The uninterrupted power supply of the electrical systems used for this (e.g. sprinkler water pumps, mechanical smoke exhausts, firemen lifts) can be attained with «Class E90» cable systems. Planning Planning an electrical safety system means finding answers to the questions: Which parts of the building requires which level of safety? Which electrical system has to operate for how long? Which circuits are involved (safety circuits)? Which is the best cable routing for these circuits? Are there restrictions concerning fire load, etc.? Only then the selection of appropriate cables and support systems can begin
61 61 General Conditions of Sale and Delivery of LEONI Studer AG, Däniken. Valid July 2007 (replaces all previous versions) Unless agreed to the contrary, the following conditions shall apply to all deliveries: 1. Conclusion of contract 1.1 These General Conditions of Sale and Delivery shall be deemed to be accepted at the latest upon acceptance of our goods. Amendments to any of these Conditions of Sale and Delivery shall be invalid unless confirmed by LEONI Studer AG in writing. 1.2 All our offers are prepared on the basis of the details or planning materials placed at our disposal or transmitted to LEONI Studer AG. Our offers shall no longer be binding if details, dimensions or plans are subsequently amended. Unless otherwise agreed in writing, the prices and conditions offered shall remain valid only as long as the raw material costs remain unchanged; increases in the prices of raw materials occurring before the definitive award of the contract will be charged additionally. Brochures and catalogues shall not be binding unless agreed elsewhere in writing. Details contained in technical documentation shall only be binding if they have been expressly promised by LEONI Studer AG in a separate written contract. 1.3 An order shall only be valid upon confirmation by us in writing. If the goods ordered are on stock, the order shall be deemed to be accepted if it is received by LEONI Studer AG and not refused within one working day; basic agreement orders remain reserved. Our confirmations of order shall be checked in detail. Any discrepancies must be notified to LEONI Studer AG within three working days at the latest after the date of the confirmation of order. Silence on the part of the purchaser until the expiry of this period shall be deemed to be acceptance of our order confirmation. After expiry of this period, we shall be free to manufacture and invoice the goods ordered in accordance with the order confirmation. 1.4 Any requests for changes received after the contract has been concluded may only be taken into account if we are able to agree to a change in the light of the state of the preliminary works. The costs and delivery delays resulting from such subsequent changes shall be borne by the purchaser. 1.5 If any of the provisions of these Conditions of Sale and Delivery shall prove to be null and void or non-binding in whole or in part, such nullity or non-binding character shall only apply to the provision concerned. Such null and void or non-binding provision shall be replaced by such substitute solution that comes closest to the intended purpose of the null and void or non-binding provision in question. 2. Termination of contract by the supplier If LEONI Studer AG wishes to terminate the contract, it shall inform the purchaser immediately after discovery of the significance of the event; this shall also apply if an extension of the delivery period has initially been agreed. In the event of a termination of the contract, we shall be entitled to remuneration for those deliveries and services already rendered. The purchaser shall not be entitled to any claims for damages by virtue of such termination of contract. 3. Exclusion of further liability of the supplier and consequential losses The cases of substantial breach of contract, the legal consequences thereof and all claims by the purchaser for whatever legal reason are regulated definitively in these Conditions. In particular all claims for damage, diminution, termination of the contract or withdrawal from the contract not expressly specified shall be excluded. In no case shall the purchaser be entitled to claims for compensation for damage which has not been incurred by the delivered item itself, such as loss of production, loss of use, loss of orders, lost profit and other direct or indirect losses. These restrictions shall not apply in the case of unlawful intent or gross negligence on the part of LEONI Studer AG, but they shall also apply in the case of unlawful intent or gross negligence on the part of auxiliary personnel. 4. Supplier s right of recourse Should any person be injured or third party property be damaged as a result of the acts or omissions of the purchaser or its auxiliary personnel, and should claims be made against LEONI Studer AG on this basis, the latter shall have a right of recourse against the purchaser. 5. Order quantity 5.1 Shortage- or excess lengths of +/ 10 % are permitted. 5.2 We are allowed to deliver in different part lengths, because of production and commercial reasons. The accuracy of measuring is +/ 0.5%. 6. Details of dimensions and weight and structural variations All details of diameters and weights of products are without obligation and are approximate. We reserve the right to make variations in the structure of products for production or raw material reasons. 7. Prices 7.1 The prices for deliveries within Switzerland are exclusive of VAT, without spools but with packaging, carriage paid to the recipient for rail parcels or to the Swiss destination station for wagonloads. For deliveries up to 30 kg by post or parcel service, the purchaser shall be charged for the entire postage. For small quantities an additional processing fee will be charged based on the actual valid price list. 7.2 The prices for deliveries abroad are ex works (Incoterms 2000), including packaging and non-returnable packing containers plus applicable taxes and other levies. If dispatched on spools of Kabeltrommel GmbH & Co. KG, D Cologne (KTG), the provision of Art shall be complied with. The list of prices for deliveries abroad include a fixed basic metal price which may vary in the individual product segments. The calculation basis for the metal selling price shall be the price on the relevant metal exchange on the day preceding the receipt of the order. A metal cost procurement supplement may be charged. The selling price shall be increased or reduced by the difference between the basic metal price and the metal exchange price. 8. Terms of payment 8.1 The period of payment shall be 30 days net for all deliveries after date of invoice. Deductions of discounts without entitlement shall be reclaimed. 8.2 We reserve the right to request payment in advance and immediate payment. 8.3 In the event of a delay in payment, we reserve the right to withhold planned deliveries and to charge interest on arrears at the usual bank discount rate applicable at the place of our company s head office, at least, however, 0,6 % per month. 8.4 Payments shall be made by the purchaser to our domicile in cash or by bank transfer free of deductions for charges, taxes or fees, and excluding set-off against other claims. In the case of payment by cheque or bill of exchange, the collection charges, the discount charges and interest shall be refunded to us. 8.5 The date of payment shall be deemed to be the date on which the money is at our disposal. 8.6 In the event of a failure to comply with our terms of payment for goods supplied, we reserve the right to withdraw from the contract (Swiss Code of Obligations, art. 214). 9. Delivery period and delivery delay 9.1 The delivery dates confirmed by us shall be ex Däniken works and shall be specified such that they can normally be met. A delivery delay resulting from force majeure, operating interruptions, difficulties in the procurement of materials and the like shall not entitle the purchaser to withdraw from the contract nor represent grounds for compensation for direct and indirect losses caused by the delay. 9.2 The purchaser shall be entitled to claim compensation for delays which are demonstrably due to our fault and where the purchaser can furnish evidence of direct losses resulting from this delay. If the purchaser receives a substitute delivery, the claim for compensation for delay shall be forfeit. 9.3 Compensation for delay shall amount to 0.5 % for each full week of the delay, and shall be limited to a total of 5 % of the contractual price for the delayed part of the delivery. The first two weeks delay shall not give rise to any claim to compensation for delay
62 Dispatch, transport and insurance 10.1 Special wishes concerning dispatch, transport and insurance shall be notified to us in good time. Transport shall always be at the purchaser s risk. Complaints in connection with the dispatch or transport shall be addressed by the purchaser to the last haulage contractor without delay after receipt of the delivery or the freight documents; the goods being complained of are to be accepted with reservations The purchaser shall be responsible for insurance against damage of any kind. 11. Transfer of benefit and risk 11.1 Benefit and risk shall pass to the purchaser when the consignment (goods and packaging) leave the works or are ready for dispatch or collection, even if the place of dispatch is not the place of performance If dispatch is delayed at the purchaser s request or for other reasons for which we are not responsible, the risk shall pass to the purchaser at the time originally intended for delivery ex works. From this time on, the deliveries shall be stored and insured at the purchaser s cost and risk. 12. Loaned spools and packaging 12.1 Cardboard, plastic and paper packaging is included in the price for all deliveries For deliveries within Switzerland, dispatch spools will be made available to purchasers free of charge for a maximum of 6 months from the date of delivery. The loaned spools shall be returned at our expense either by LEONI Studer AG s own trucks, by hauliers authorised by LEONI Studer AG or by Cargo Domizil. The spools must be in good condition. The purchaser shall be liable for loss or damage. After expiry of the 6 months period, we shall send a reminder concerning the loaned spools, after which they shall be charged to the purchaser If delivery is made on the spools of KTG, KTG shall charge for the spool rental directly in accordance with their conditions. After becoming free, these spools shall be notified to KTG as being free. The appropriate conditions of KTG shall be deemed to be an integral part of our General Conditions of Sale and Delivery and shall be sent on request. 13. Warranty / complaint 13.1 The purchaser shall examine the objects delivered immediately upon arrival for shortages and obvious defects. These shall be notified in writing within 10 days after arrival of the goods, with details of the order and delivery note number, failing which no right may be derived from such defects If significant defects are established or if a test shows that the agreed construction conditions have not been fulfilled, we shall supply a replacement free of charge within a reasonable period of time, provided that we are responsible for the faults For all LEONI Studer AG cables, we warrant a perfect finish of the material supplied for a period of two years. The warranty shall begin upon dispatch of the delivery ex works or with start-up if we are responsible for installation. In particular, we assume the following liability for defects: all faults for which we are responsible and which are reported to us within the said period without delay and which under normal conditions with proper handling have led to disruption shall be remedied as quickly as possible at our expense by means of repair or replacement of the defective part. The parts replaced shall become our property. However, we shall only be responsible for such faults as shall be demonstrably attributable to material defects or faulty workmanship of LEONI Studer AG. If the laying did not take place through our personnel or under our supervision, or if fittings of third-party origin are incorporated in the cables by the purchaser, we shall, in case of doubt, be entitled to regard third-party fault as the cause of the disruption. We shall not accept any claims based on the faults beyond the obligation to replace as described above, in particular claims for compensation for indirect losses. In the event that a defective stretch of cable is replaced, the warranty does not apply to the remaining network. More extensive claims for direct or indirect losses shall be excluded. 14. Returns Goods returned for reason of non-use, unsuitable length etc. shall only be accepted on the basis of a prior written agreement. Expenses incurred shall be deducted from credit notes. No credit can be given for goods not in accordance with the catalogue, goods supplied according to particular specifications, goods used rarely or no longer, or incomplete goods or goods no longer in perfect condition. 15. Laying and installation If laying and installation are an integral part of our scope of performance, they shall be carried out in accordance with separate installation conditions. The liability shall apply in each case only to such parts as are supplied by us, except for a faulty installation of the equipment or parts of the equipment caused by us. 16. Proprietary rights Technical materials such as drawings, descriptions, illustrations and the like are our intellectual property and may be neither copied nor reproduced nor made available to third parties or rival companies without our express consent. The purchaser shall bear all risks if third party proprietary rights are infringed by a delivery according to its drawings or other details. 17. Reservation of title 17.1 We reserve title to the delivery until it has been paid in full. The purchaser shall be obliged to take the measures necessary for the protection of our title We shall be entitled to have the reservation of title entered in the appropriate register with the co-operation of the ordering party. 18. LEONI Social Charter The purchaser is obligated to respect the Declaration on Social Rights and Industrial Relationships at LEONI (LEONI Social Charter). The purchaser has access to the LEONI Social Charter via the website of LEONI ( or may request a copy of the LEONI Social Charter from LEONI Studer AG at any time. Any serious infringement or recurrent infringements of the LEONI Social Charter by the purchaser establishes the right of LEONI Studer AG to termination without cause and notice for individual as frame contracts with the purchaser. 19. Applicable law and legal venue 19.1 Swiss substantive law shall apply to the exclusion of the UN-Convention on Contracts for the International Sale of Goods The legal venue for all disputes in connection with this contract shall be Olten, Switzerland. However, we also reserve the right to assert our rights at the purchaser s domicile. Däniken, July
63 63 Further products BETAtherm Premium, halogen free and electron-beam cross-linked lead wires Temperature resistant, increased dielectric strength, easy stripping BETAflam flex Premium flexible connection and power cables Good resistance to aggressive media, halogen free and flame retardant BETAflam CHEMAflex Oil and chemical resistant connection and power cables Temperature resistant, halogen free, flame retardant, easy stripping BETAtrans Premium flexible halogen free connection and power cables Excellent mechanical and dielectric strength BETAjet 400 Hz ground power cable systems For mobile and static applications BETAlux Media resistance 5 kv-primary cables Feeder cables for airfield lighting BETAflam Fire resistant safety cables for highest demand Flame retardant, low smoke density, no flame propagation BETAfixss Laying systems with circuit integrity under fire BETApower Medium voltage power cables TRI-DELTA Low voltage power cables GKN and GN-CLN Flexible single-core cable BETAflam TRAFO-FLEX Accessories for cables BETAflam Solar Double insulated lead wires Electron-beam cross-linked and halogen free For solar power applications PV connection systems BETAsolution We are always at your disposal cable management as complete support
64 Find out more: Business Unit Infrastructure & Datacom LEONI Kerpen GmbH Zweifaller Strasse Postfach 63 D Stolberg Germany Phone +49 (0) Fax +49 (0) [email protected] LEONI Studer AG Herrenmattstrasse 20 Postfach 63 CH Däniken Switzerland Phone +41 (0) Fax +41 (0) [email protected] / e / 1500 Expl.
The Quality Connection. BETAflam Fire safety cables
The Quality Connection BETAflam Fire safety cables 2 We connect tomorrow's world already today. BETAflam Safety cables Halogen-free and environmentally friendly cables and single cores for applications
FIRE RESISTANT CABLE CONSTRUCTION OF CABLES
FIRE RESISTANT CABLE In all fire disasters, fire smoke, heat and toxic fumes are the main obstacles to safe evacuation of a building or area. A major contribution towards overcoming these hazards is the
BETAtrans. Cables and Systems for Rolling Stock. Edition 2006
BETAtrans Cables and Systems for Rolling Stock. Edition 2006 Info Consulting and Sales By Phone To ask for Information or to place an order please use the following number: +49 (0)9172-6844-11 By Fax For
The Quality Connection. BETAflam Safety cables for highest demands
The Quality Connection BETAflam Safety cables for highest demands 2 For solutions that will still be standard tomorrow. BETAflam Safety cables Thanks to their proven quality, BETAflam safety cables are
Fire Resistant Cables
109/4 Fire Resistant Cables SR 114H Standard - SR 114E Enhanced BS 5839-1 BS 7629-1 BS 6387 BS 8434-1/2 BS 6425 BS 7622 EN 50200 World-wide recognized high quality cables Firecel SR114 are used in: Data
RADOX railway cables acc. to EN 50264 and EN 50306. Edition 2009
RADO railway cables acc. to EN 50264 and EN 50306 Edition 2009 Bridging our know how Interdisciplinary knowledge The HUBER+SUHNER Group is a leading international manufacturer of electrical and optical
FLEXIBLE INDUSTRIAL CABLES H07RN-F TENAFLEX SR
FLEXIBLE INDUSTRIAL CABLES H07RN-F TENAFLEX SR Standards : CENELEC HD 22.4 NF C 32-102-4 DIN VDE 0282-1 and VDE 0282-4 BS 6007 and BS 6500 IEC 60245-4 Rated voltage Rated voltage: 450/750 V (Use up to
BRÖCKSKES D-VIERSEN PV1-F 4,0 mm BRÖCKSKES D-VIERSEN PV1-F 4,0 mm d d 2 2 C VDE-REG.-Nr. 8292 10/2009
d BRÖCKSKES BRÖCKSKES D-VIERSEN D-VIERSEN PV1-F PV1-F 4,0 mm 4,0 2 mm VDE-REG.-Nr. 2 C 8292 10/2009 s - THE COMPANY DIN EN ISO 9001 More than 60 years of experience in temperature measurement and control
Chemical resistance Accidental
Industrial flexible cable, insulation and outer sheath in elastomer Description Application TITANEX flexible cable is intended for installations with moving equipment, electric appliances and for building
Festoon 715 P PUR cable for flexible application in festoon systems
CABLES FOR CRANE AND CONVEYOR APPLICATIONS Festoon 715 P PUR cable for flexible application in festoon systems S AB BRÖCKSKES D-VIERSEN Festoon 715 P 1 x 16.0 mm 2 C Marking for Festoon 715 P 07150162:
www.ptranscable.com We specialize in low voltage cables including: Stranded Single Cable H07V-R Flexible Single Cable H05V-K
P-trans, meaning power transistor, is a well known cable manufacturer based in Aan - Jordan. The production plant produces all sorts of high quality low tension cables and is a leader in the industry supplying
CONFLEX ELECTRIC CABLE
CONFLEX ELECTRIC CABLE CONFLEX - 0.6/1kV Flexible VSD/EMC Cables Applications WW VSD/EMC cables are manufactured for use where electrical interference distorts signal transmission in electric motors. Standard
Fire retardant IEC 60332-1
300 / 500 V Description Approval Certificates VDE Reg N 7691 Application In dry and moist rooms for light mechanical stresses. Outdoors only when protected. Not in water. As supply and interconnecting
AFUMEX LSX LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 BASEC APPROVED PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:
PRODUCT DATASHEET & APPLICATIONS GUIDE BASEC APPROVED AFUMEX LSX LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 KEY BENEFITS: BASEC approved for the full size range of BS8436 (1.0mm 2 to 2.5mm 2
Corporate Profile ROYAL. MODERN ROYAL ELECTRIC Ideal Power Solution MRE ELECTRICAL, INSTRUMENTATION & COMMUNICATION SYSTEMS
Corporate Profile MODERN ROYAL ELECTRIC Ideal Power Solution ROYAL MRE ELECTRICAL, INSTRUMENTATION & COMMUNICATION SYSTEMS MAJOR STOCKIST >>> CATHODIC PROTECTION CABLES >>> LOW VOLTAGE CABLES >>> MEDIUM
Global cable expertise for rolling stock
Global cable expertise for rolling stock Global cable expertise for rolling stock Single and multicore Low voltage control cables Jumper cables HV roof cables (25 kv) rubber cables for power needs of locomotives
CABLES FOR PHOTOVOLTAIC SOLAR ENERGY INSTALLATIONS FOR CLEAN ENERGY
CABLES FOR PHOTOVOLTAIC SOLAR ENERGY INSTALLATIONS FOR CLEAN ENERGY One Company Connecting The World POWERFUL PRESENCE PRODUCTS PERFORMANCE PEOPLE General Cable has been a wire and cable innovator for
Power and Wiring Cables
1 Single-Core PVC 1X...................... 1: Single-Core PVC/PVC 1Y.................. 1: Flat Twin & Flat Three Core PVC /Y........ 1: Multicore XLPE/LSF/SWA/LSF BS Control Cable.............................
with coloured cores and overall copper screen UL/CSA... 17
CONTENT Cable Track Cables y SD 200 extremely flexible TPE/PUR data cable with coloured cores for continuous movement..... 6 y S 200 extremely flexible TPE/PUR control cable with numbered cores for continuous
ScottishPower Distribution Cables & Equipment. Metal Theft
ScottishPower Distribution Cables & Equipment Metal Theft April 2012 As an aid to deterring to metal theft this booklet has been put together to help identify the types of utility power cables and associated
VIPERFLEX ELECTRIC CABLE
VIPERFLEX Flexible Low Voltage Electric Cable - 0.6/1kV (Rubber insulated) H07 RN-F & H07 BN-F Single Core 2-Core 2-Core and Earth 3-Core and Earth 4-Core and Earth Multi-Core and Earth H07 RCN-F & H07
FIRE RESISTANT CABLES FP200 GOLD
FIRE RESISTANT CABLES FP200 GOLD FIRE RESISTANT CABLES FP200 GOLD BS7629-1:2008 Certificate No 077f Certificate No 077k FP200 GOLD The original highly durable and dressable, easy to terminate and install
ENERGY. TECWATER S1BN8-F 0,6/1 kv. Cable for Water Application
ENERGY TECWATER S1BN8-F 0,6/1 kv Cable for Water Application Technical Data Electrical parameters Thermal parameters Trademark Type designation Specification Approval Application Rated voltage Maximum
International Electrotechnical Commission Standards
International Electrotechnical Commission Standards Standard IEC 60028 IEC 60038 IEC 60050-461 IEC 60055-1 IEC 60055-2 IEC 60092-101 IEC 60092-350 IEC 60092-351 IEC 60092-352 IEC 60092-353 IEC 60092-354
LEAD FREE FIREX. Interlock Armored Cables TECK90 and MC Industrial Cables. w w w. n e x a n s e n e r g y. c o m
FIREX Interlock Armored Cables TECK90 and MC Industrial Cables LEAD FREE O V E R 1 8 0 Y E A R S O F E X P E R I E N C E 866-663-9267 w w w. n e x a n s e n e r g y. c o m Interlock Armored Cables Introduction....2
INTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 60502-1 Second edition 2004-04 Power cables with extruded insulation and their accessories for rated voltages from 1 kv (U m = 1,2 kv) up to 30 kv (U m = 36 kv) Part 1: Cables
COAX Cables Radio Frequency Cables
COAX Cables Radio Frequency Cables Contents Page Table of contents Pictographs General information Introduction Types and abbreviations Temparature range Construction Characteristics Special constructions
PROFIBUS cable. PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications
Data Sheet 10/63-6.47-EN Rev. D PROFIBUS cable PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications PROFIBUS PA cables Non-Ex (Hazardous) applications Ex (Hazardous) applications
The most important matter is to select the right product based on the environment in which it will be installed and on its use or application.
Communication cables and burning behaviour international regulations Different regulations and standards apply depending on the geographic location. Europe is normally governed by CENELEC (EN), but in
Important Information: Complete Terms and Conditions are printed on sales invoices
Important Information: Complete Terms and Conditions are printed on sales invoices Notice: L&H Group is continually working to improve and add new products to the Cable Express product range. For this
3.6/6 kv XLPE insulated cables 5. 6/10 kv XLPE insulated cables 15. 8.7/15 kv XLPE insulated cables 25. 12/20 kv XLPE insulated cables 35
CONTENTS INTRODUCTION 1 Cable selection, cable specification, cable services CABLES Constructional data: 3.6/6 kv XLPE insulated cables 5 SECTION 1 6/10 kv XLPE insulated cables 15 SECTION 2 8.7/15 kv
PROFIBUS cable. for PROFIBUS-PA and -DP 10/63-6.46 EN
for PROFIBUS-PA and -DP 10/63-6.46 EN CPN 080/CPE 080-Ex PROFIBUS-PA basis cable AWG 18, 0.88 mm 2 Use For fixed installation indoor and outdoor, on racks and in conduits. Application Fieldbus cable for
Flexible cables for submersible products
Flexible cables for submersible products Standards SUBCAB cables complies with the following general standards: IEC 6045 (general) IEC 608 class 5 (conductor) IEC 608-- CLAUSE 9 (oil resistant) IEC 608--
Series 8146/5-V37 and Series 8150/5-V37
www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection
Comprehensive safety concepts for building applications
Comprehensive safety concepts for building applications Preventive fire protection Experience, know-how, competence, quality and safety pyrofil for safety Fire reaction Dätwyler is the first european manufacturer
Fibre optic cables MDIC LSZH
MDIC LSZH MDIC LSZH - Indoor Access Cable. Micro Drop Installation Cable, special Access cable with low bend radius, no waterpeak G.657.A fibres. Ruggedized construction with excellent performance, easy
Flexible Control Cables
Works photo: KUKA Flexible Control Cables A Flexible Control Cables Since generations people try to build machines and plants which shall take on different functions. To raise, sink, slide, drill, transport
Gulf Cable & Electrical Ind. Co.
CONTENTS INTRODUCTION PRODUCT RANGE I PRODUCT DATA TABLES XLPE INSULATED 600/1000V CABLES Two Core Cables CU/XLPE/PVC/LC/PVC/SWA/PVC 1 Three Core Cables CU/XLPE/PVC/LC/PVC/SWA/PVC 2 Four Core Cables CU/XLPE/PVC/LC/PVC/SWA/PVC
CLEVELAND CABLE LOCATIONS
A WORLD POWER IN CABLE SUPPLY THE CABLE AND ACCESSORY CATALOGUE 2011 2 CLEVELAND CABLE LOCATIONS CLEVELAND CABLE LOCATIONS 3 As is illustrated within our catalogue, we stock a comprehensive range of cables
ISO 9001 ISO 14001 CABLES AND WIRES CATALOGUE 2008
ISO 9001 ISO 14001 CABLES AND WIRES CATALOGUE 2008 INTRODUCTION... 4 CHAPTER I SINGLE CORE NON-SHEATHED CABLES H05V-U, H05V-R, H05V-K... 6 H05V2-U, H05V2-R, H05V2-K... 7 H07V-U, H07V-R, H07V-K... 8 H07V2-U,
Tri-Rated Flexible PVC Equipment Wire
Application: High temperature, flame retardant wire designed for use in the switch control, relay and instrumentation panels of power switchgear and for purposes such as internal connectors in rectifier
< SD 200 C TP Continuously flexible TPE/PUR paired data cable with coloured cores and overall copper screen... 10
CONTENT General < The Company..................................................................................... 3 Customized cables for different applications < Data / POF Cables POF-LWL and hybrid
Offshore Transformer Platform. Technical Standard. Energinet.dk. HV, MV, LV and Signal Cables and Cable Routing
Offshore Transformer Platform Technical Standard Energinet.dk HV, MV, LV and Signal Cables and Cable Routing ETS - 03 Rev. 1 Acadre doc. 44858-09 Revision survey Chpt. Description Revision Date Resp. -
MV CABLE TYPE C 33-226
MV CABLE TYPE C 33-226 Standards : CENELEC HD 620 C 33-226 Rated voltage Rated voltage : 12/20 (24) kv Design 1 Stranded aluminium, class 2 conductor 2 Extruded conducting screen on conductor 3 XLPE insulation
Fire Performance Standard
Fire Performance Standard At present, in cable industry, Fire Retardant, Low Smoke Halogen Free (LSZH), Low Smoke Fume (LSF) and Fire Resistant cables are all described as Fire survival Cables. Flame Retardant
High Speed Cables for Enterprise Data Solutions Business Unit Telecommunication Systems
High Speed Cables for Enterprise Data Solutions Business Unit Telecommunication Systems 2 The LEONI Group Cable competence for different industrial markets LEONI is a leading supplier of cable systems
Specializing in the cable business for over 38 years, PT. SUPREME CABLE
Specializing in the cable business for over 38 years, PT. SUPREME CABLE MANUFACTURING & COMMERCE Tbk. (PT. SUCACO Tbk) has grown steadly to become a largest and leading cable manufacturer, with international
108-93018 05 APR 2016 Rev M
Product Specification 108-93018 05 APR 2016 Rev M Copper LAN Cable 1. SCOPE 1.1. Content This specification describes the general requirements for CommScope copper LAN cable. 2. APPLICABLE DOCUMENTS The
Flexible and safe solutions, for decades. Cables for alarmand safety systems
Flexible and safe solutions, for decades. Cables for alarmand safety systems 2 We offer the widest range of cables on the market for every kind of installation. It s all about reliability. It is always
Gulf Cable & Electrical Ind. Co.
CONTENTS INTRODUCTION PRODUCT RANGE I PRODUCT DATA TABLES Irrigation 1 Coaxial s for T.V/ Satellite Antenna etc 2 Data Transmission s - 4 pair 24 AWG 3 TELEPHONE CABLES Telephone cables CCP-LAP & CCP-LAP-SS
Fire Resistance and Safety in Case of Fire
Fire Resistance and Safety in Case of Fire Franck GYPPAZ Nexans Research Center [email protected] April 2014 Page 1/12 Table of content 1 Introduction... 3 2 Fire development... 3 2.1 Ignition...
WHITE PAPER Fire & safety performance standards
WHITE PAPER Fire & safety performance standards Terminologies describing Fire Performance Terminologies describing Fire Performance often present a challenge to understand as how they apply to a cable
Cable flexibility Flexible. Chemical resistance Accidental
H07RN-F Industrial flexible cable, insulation and outer sheath in elastomer Description pplication H07RN-F flexible cable is intended for installations with moving equipment, electric appliances and for
e-mobility Special cables for electric vehicles Coroplast Fritz Müller GmbH & Co. KG Tapes Cables Cable Assemblies
www.echtzeit.com e-mobility Coroplast Fritz Müller GmbH & Co. KG Tapes Cables Cable Assemblies Special cables for electric vehicles Wittener Straße 271 D-42279 Wuppertal Phone +49(0)202.2681.228 Fax +49(0)202.2681.360
The Quality Connection. Underwater cables for Oceanography & Seismic Systems
The Quality Connection Underwater cables for Oceanography & Seismic Systems 2 Welcome www.leoni-marine-technologies.com Cable Solutions for Marine Technologies A consistent focus on the market, in-depth
Airdac CNE and SNE, 600/1000V, Polyethylene Sheath, SANS 1507, NRS 063 & NRS 017
Airdac CNE and SNE, 600/1000V, Polyethylene Sheath, SANS 1507, NRS 063 & NRS 017 Conductor: Hard Drawn Copper Conductor Class 2 Insulation: LV-XLPE Phase Color Code(SNE): Red, Black & Bare Copper Phase
DATA SHEET SERVO LK SMS FX8PLUS SIGNAL
Application LAPP servo cables according to Siemens * (see footnote) Standard FX8008 PLUS SIGNAL are a new generation of very highly flexible screened signal (encoder and resolver)- cables (P/Ns 00277101
Flygt flexible cables
Flygt flexible cables Contents Standards General SUBCAB 4 Screened SUBCAB 6 Rubber cable type: NSSHÖU-J 7 Screened rubber cable type: NSSHÖU../E + ST 8 FGB screened rubber cable 9 PUR control cable 0 HCR
6 ELECTRICAL PARAMETERS
6 ELECTRICAL PARAMETERS For power, low voltage and medium voltage cables, cross section nominal areas are calculated in taking into account several parameters as: permissible current carrying capacities
C a b l i n g s o l u t i o n s a t t h e c o r e o f R a i l w a y N e t w o r k s
C a b l i n g s o l u t i o n s a t t h e c o r e o f R a i l w a y N e t w o r k s High Speed Line (HSL) Zuid The Netherlands - Siemens project Dedicated 100 km high speed rail line between Antwerp (Belgium)
KNOW YOUR OPTIONS: 230 KV POWER CABLES
KNOW YOUR OPTIONS: 230 KV POWER CABLES 71 CONDUCTOR MATERIAL AND SIZE Conductor material is a matter of both customer preference and required current carrying capacity At 230 kv, copper is most common
High Voltage Systems. Today. The history of cables
High Voltage Cables High Voltage Systems Today Prysmian Cables and Systems B.V. is part of the Prysmian Group, a leading player in the industry of high-technology cables and systems for energy and telecommunications,
MEDIUM VOLTAGE CABLES Up to and including 36 KV
MEDIUM VOLTAGE CABLES Up to and including 6 KV NOTICE As this catalogue is not intendedto cover all of LIBAN CABLES SAL possibilities in special cables manufacturing, the hereafter listing of the types
VDE-approved PVC-Control Cables
Works photo: HELUKAEL VDE-approved PVC-Control Cables VDE-approved PVC-Control Cables This certification/licency is issued according to the rules of the HAR Agreement, wherein the certification/ licency
CABLE SPECIFICATION CAN CAB RJ45-SUBD9
CABLE SPECIFICATION All technical information contained in this document is the exclusive property of STI and may neither be used nor disclosed without its prior written consent. AAV 33801 1/8 Connector
Section 5 161 kv Power Cables
Know Your Options: 161 kv Power Cable 61 material and size material is a matter of both customer preference and required current carrying capacity Copper conductor common for larger loads When both copper
CONTENT. Robot cables. page. < The company... 3. < W - worldwide... 4. < Certifications... 5. < Clientele / supplier numbers... 6
CONTENT page < The company............................................................................... 3 < W - worldwide...............................................................................
Communication, Signal & Data Cables
Communication, Signal & Data Cables Used for indoor installation and interconnection of transmission, telephone, telegraph and electronic equipment as well as media equipments www.alfanar.com Communication
ENERGY. TECSUN DUO (PV) Twin Cables for Photovoltaics
ENERGY TECSUN DUO (PV) Twin Cables for Photovoltaics Auswahlkriterien Manufacturer Trademark Approvals Application Prysmian Kabel und Systeme GmbH Kabel- und Leitungswerk Neustadt bei Coburg / Germany
FOREWORD ONE OF THE WORLD S BIGGEST COMPANIES IN THE SECTOR.
OFFSHORE CABLES FOREWORD ONE OF THE WORLD S BIGGEST COMPANIES IN THE SECTOR. General Cable Corporation is one of the world s leading cable manufacturing companies. In its work it has contributed decisively
5SV Residual Current Protective Devices
s Siemens AG 2013 SENTRON 5SV Residual Current Protective Devices New portfolio for reliable personnel, material and fire protection Safe protection against residual currents Residual current protective
INTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 61156-5 First edition 2002-03 Multicore and symmetrical pair/quad cables for digital communications Part 5: Symmetrical pair/quad cables with transmission characteristics up
The color scheme for the fibers in the cable complies with the Telcordia (formerly Bellcore) specification.
10 Cables The cables referred to below are provided with standard single- and multimode fibers. Other commercially available fibers can be provided on request. The bare fibers are colored in all cases
KNOW YOUR OPTIONS: 69 KV XLPE POWER CABLE
Know Your Options: 69 kv XLPE Power Cable 3 material and size material is a matter of both customer preference and required current carrying capacity Copper conductor common for larger loads When both
EXAMPLE OF RELEVANT STANDARDS
Optical Cables Electronics market NEXANS a n d Th e El e c t r o n i c s Ma r k e t Nexans products offer a high technology knowledge and an international know-how, which has been experienced in different
Quality Reliability Innovation. ISO 9001 : 2000 CERTIFIED BY AFAQ No. QUAL / 1997 / 7034 a COPPER TELECOMMUNICATION CABLES
Quality Reliability Innovation ISO : CERTIFIED BY AFAQ No. QUAL / 7 / 7 a COPPER TELECOMMUNICATION CABLES COPPER TELECOMMUNICATION CABLES CONTENTS 7 NOTICE INTRODUCTION QUALITY ASSURANCE RECOMMENDED ORDERING
ALARMLINE ANALOGUE Linear Heat Detection System
ALARMLINE ANALOGUE Alarmline Analogue sensor cable senses temperature variations by continuously monitoring the resistance of specially doped N.T.C. polymeric insulation. A change in temperature produces
01. HARTING RJ INDUSTRIAL RJ45 ETHERNET CONNECTORS
. HARTING RJ INDUSTRIAL ETHERNET CONNECTORS Ethernet is is coming up to standard industrial interface. Therefore, automation devices such as controllers, sensors and actuators feature possess on one or
DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155
DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155 Technical information Version: 07.14 General Function The speed sensors family DSD.70 are suitable for generating
The Handbook 2013 EDITION
The Handbook 2013 EDITION Trust Als you safe Alsecure is the cable you can stake your reputation on when safety and security are critical to maintain circuit integrity for mains power, lighting, alarms,
Cables and Accessories Selection Guide
Cables and Accessories Selection Guide From data centers to robotics to patient monitoring equipment, we re committed to enabling the next generation of faster, smaller and smarter design. 3M offers an
The Quality Connection. Cable Solutions for Mobile Networks Business Unit Telecom
The Quality Connection Cable Solutions for Mobile Networks Business Unit Telecom Connection Technology for Wireless Communication Systems A consistent focus on the market, in-depth sector and product knowledge,
Pressure monitoring equipment for oil-sf 6. bushings, type GOEK
Pressure monitoring equipment for oil-sf 6 bushings, type GOEK Installation and maintenance guide 5693 827-6 en, Rev. 3, 2002-01-30 This document must not be copied without our written permission, and
The optimum material solution for Low Voltage energy cables
The optimum material solution for Low Voltage energy cables About Borealis and Borouge Borealis is a leading provider of innovative solutions in the fields of polyolefins, base chemicals and fertilizers.
FIBER-OPTIC CABLES LWL-KABEL
FIBER-OPTIC CABLES LWL-KABEL FIBER-OPTIC LOOSE TUBE OUTDOOR CABLE LWL-BÜNDELADER AUSSENKABEL TECHNISCHE DATEN - Technical Data A-DQ(ZN)B2Y 1200 N A-DQ(ZN)B2Y 2500 N ECO-KABEL - ECO cable STANDARDKABEL
Commercial Coaxial Cable
Commercial Coaxial Cable For the Best in COMMERCIAL TV Reception Solutions! Do you require a Digital TV reception system for your next project? Matchmaster can supply For The Best Design and supply of
HIGH SPEED COMMUNICATIONS PLENUM CABLE CATEGORY 5e CMP FEP JACKETED, PVC-FREE UNSHIELDED TWISTED PAIR (UTP)
Cable Specification Category 5e CMP HIGH SPEED COMMUNICATIONS PLENUM CABLE CATEGORY 5e CMP FEP JACKETED, PVC-FREE UNSHIELDED TWISTED PAIR (UTP) This cable specification complies with the electrical transmission
Comparative study for cables and busbars
Comparative study for cables and busbars Preliminary considerations To compare the prices of two categories of product as different as traditional cables and busbars, it is necessary to make some preliminary
MEDIUM VOLTAGE POWER CABLES
MEDIUM VOLTAGE POWER CABLES CONTENTS 1 GENERAL INTRODUCTION 4 TECHNICAL INFORMATION 15 25 35 45 Single Core XLPE Insulated PVC Sheathed Cables UNARMOURED CABLES COPPER UNARMOURED CABLES ALUMINUM ALUMINUM
RF & Microwave cable assemblies C291
ERTIFIED C AS 9100 RF & Microwave cable assemblies C291 B CONTENTS Pages Introduction... B-4 Specify the right cable for your application... B-5 Finder guide cables vs insertion loss... B-6 to B-7 Flexible
EE-SPY801/802. Photomicrosensors for detecting wafer-carrier mounting. Wafer-carrier Mounting Photomicrosensors. Ordering Information.
Wafer-carrier Mounting Photomicrosensors EE-SPY1/ CSM_EE-SPY1 DS_E_3_ Photomicrosensors for detecting wafer-carrier mounting. The mounting position is set with a pedestal. The contact surface with the
Please also see 10 golden rules for correct Saniflo installation on www.saniflo.co.uk
1. Description Sanicom is a lifting pump for wastewater used in commercial applications (restaurants, hairdressing salons, the catering industry etc.). The unit operates automatically, has a high performance
The Quality Connection. BETAflam Solar Photovoltaic power cables
The Quality Connection Photovoltaic power cables 2 We connect technology, efficiency & ecological awareness already today. Clean cables for clean energy. Whether it is an off-grid application or a grid
The best connection in plant engineering Industrial Projects
The best connection in plant engineering Industrial Projects The Quality Connection 2 The optimum solution for any plant. LEONI Business Unit Industrial Projects your expert for a market that requires
08. SEK IDC CONNECTORS
. IDC CONNECTORS connectors for flat cables enable simple and, cost-optimized device configuration. connectors are preferably used for connection within the device. HARTING offers a broad range of these
RF cables. Edition 2015
RF cables Edition 2015 Developed for highest expectations Your partner for system solutions HUBER+SUHNER is a leading international producer and supplier of electrical and optical interconnectivity components
Control cables CF880 PVC 12,5-5/ +70 3 20 2 CF881 PVC 12,5-5/ +70 3 20 4. CF890 igupur 12,5-20/ +80 3 20 6. CF891 igupur 12,5-20/ +80 3 20 8
ables......chainflex M...11.2013...plastics for longer life....eu 1million hainflexm...cost-efficient cable program for machine tools... The new igus chainflex M cables chainflex M type Rainer Rössel Head
Catalogue Câbles d Energie
Catalogue Câbles d Energie Conductores Tecnológicos S.A. www.contecsa.es Index Page Introduction 13 RV 14 RVMV 15 RVSV 16 RVFV 17 Conductores Tecnológicos S.A. 2 www.contecsa.es INTRODUCTION Câbles d Energie
British Standards BSEN 3475-513:2005
s British Standard BS 91:1998 BS 215:1970 BS 638-4:1996 BS 1990-1:1984 BSEN 3475-100:2002 BSEN 3475-201:2002 BSEN 3475-301:2002 BSEN 3475-302:2002 BSEN 3475-303:2002 BSEN 3475-305:2002 BSEN 3475-306:2005
CAVEL VS80205 MADE IN ITALY 1000 V
0,05 9,00 x 7,20 (Pet) (LSZH) Attached CE01 CE02 Sheath Colour black black red Non-migrating Polyester tape longitudinally overlapped (Pet) 25 x 23 µm Outer sheath of Thermoplastic material - black - halogen-free,