Outside Telephone Cable
|
|
- Grace Turner
- 7 years ago
- Views:
Transcription
1 Outside Telephone Cable Filled Core. Moisture Barrier. Description Soft copper wires insulated with high density polyethylene, foam skin or solid. Filled core, conformed by groups of pairs or by unit of groups of pairs. Aluminum shield and external jacket in polyethylene type moisture barrier. Construction Conductor Soft copper wires Insulation Foam skin or solid high density polyethylene. Twisted Pairs Insulated conductors are twisted into pairs Core Assembly Up to 0 pairs, groups of 0 pairs, from 00 to pairs groups of pairs, from 0 pairs and more, units of 00 pairs (each unit is conformed by groups of pairs) Spare pairs One spare pair whitered colored at the interstices of each 00 pairs unit, to guarantee nominal numbers of pairs. Identification Pairs, groups and units that conform the core, are identified by color code (Attached) Core Wrap Nonhygroscopic dielectric tape. Offers dielectric strength between core and sheath Shield Corrugated Aluminum tape both sides covered with copolymer Jacket polyethylene, abrasion, weather, and penetration to water resistant
2 Moisture Barrier Filled Core with elastomeric compound, aluminum tape both sides covered with copolymer and polyethylene external jacket, firmly bonded to external side of aluminum tape Options Manufacturing according to REA and/or Bellcore specifications Shield in Flat Aluminum tape. Armor in corrugated and copolymer covered Steel tape for direct buried and for rodent protection. Galvanized steel wires armor for vertical installations. Other Core Assemblies are available upon request. Applications Trunk cable and distribution cable networks. Special for wet locations; the elastomeric compound filler prevents the entrance of moisture to the core. Installation in ducts or raceways; for buried direct in locations without heavy traffic. CENTELSA Outside Telephone Cable, are able for voice and data transmission up to. MHz, optimizing the bandwidth of copper cables. Standards and Specifications CENTELSA Outside Telephone Cable, are manufactured under the following standards: ANSI/ICEA S808 Telecommunications cable filled, polyolefin insulated copper conductor. ANSI/ICEA S8 Telecommunications cable aircore, polyolefin insulated copper conductor. NTC0 Telecommunications copper conductor multipair cables, polyolefin insulated and covered, filled and dry. Certifications CENTELSA Outside Telephone Cable, are certified by: ICONTEC (Colombia). Norma NTC 0. Note: Other configurations, sizes, colors and length not specified herein are available upon request. 8
3 Note:. Data herein indicated are approximated and are subject to normal manuracturing tolerances. NOMINAL PAIRS STANDARD LENGTH BY REEL (m) TOTAL WEIGTH (kg/km) OVERALL SPARE PAIRS CONDUCTOR JACKET Outside Telephone Cable. Filled Core. Moisture Barrier. FoamedSkin polyethylene insulation. Standards: ANSI/ICEA S808 Telecommunications cable filled, polyolefin insulated copper conductor. NTC0 Telecommunications copper conductor multipair cables, polyolefin insulated and covered, filled and dry.
4 0 Outside Telephone Cable. Filled Core. Moisture Barrier. Solid polyethylene insulation. Standards: ANSI/ICEA S808 Telecommunications cable filled, polyolefin insulated copper conductor. NTC0 Telecommunications copper conductor multipair cables, polyolefin insulated and covered, filled and dry. Note:. Data herein indicated are approximated and are subject to normal manuracturing tolerances NOMINAL PAIRS STANDARD LENGTH BY REEL (m) TOTAL WEIGTH (kg/km) OVERALL SPARE PAIRS CONDUCTOR JACKET
5 Outside Telephone Cable Filled Core. Double Jacket. Moisture Barrier. Description Soft copper wires insulated with high density polyethylene, foam skin or solid. Core conformed by groups of pairs or by unit of groups of pairs. Filled core Aluminum shield and double Jacket (inner and outer) in polyethylene type moisture barrier. Construction Conductor Soft copper wires Insulation Foam skin or solid high density polyethylene. Twisted Pairs Insulated conductors are twisted into pairs Core Assembly Up to 0 pairs, groups of 0 pairs, from 00 to pairs groups of pairs, from 0 pairs and more, units of 00 pairs (each unit is conformed by groups of pairs) Spare pairs One spare pair whitered colored at the interstices of each 00 pairs unit, to guarantee nominal numbers of pairs. Identification Pairs, groups and units that conform the core, are identified by color code (Attached) Inner Jacket polyethylene, abrasion, weather, and penetration to water resistant
6 Core Wrap Nonhygroscopic dielectric tape. Offers dielectric strength between core and sheath Shield Corrugated Aluminum tape both sides covered with copolymer Outer Jacket polyethylene, abrasion, weather, and penetration to water resistant Moisture Barrier Filled Core with elastomeric compound, inner polyethylene jacket, aluminum tape both sides covered with copolymer and outer polyethylene external jacket, firmly bonded to external side of aluminum tape. Options Manufacturing according to REA and/or Bellcore specifications Shield in Flat Aluminum tape. Armor in corrugated and copolymer covered Steel tape for direct buried and for rodent protection. Galvanized steel wires armor for vertical installations. Other Core Assemblies are available upon request. Applications Trunk cable and distribution cable networks. Special for wet locations; the elastomeric compound filler prevents the entrance of moisture to the core. Trunk cable and distribution cable networks. Special for wet locations; the elastomeric compound filler prevents the entrance of moisture to the core. The inner jacket offers additional blocking to the entrance of humidity to the core, increases the dielectric strength pairshield and improves cable resistance to penetration of sharp objects. CENTELSA Outside Telephone Cable, are able for voice and data transmission up to. MHz, optimizing the bandwidth of copper cables.
7 Standards and Specifications CENTELSA Outside Telephone Cable, are manufactured under the following standards: Standards: ANSI/ICEA S808 Telecommunications cable filled, polyolefin insulated copper conductor. NTC0 Telecommunications copper conductor multipair cables, polyolefin insulated and covered, filled and dry. Certifications CENTELSA Outside Telephone Cable, are certified by: ICONTEC (Colombia). Standard NTC 0. Note: Other configurations, sizes, colors and length not specified herein are available upon request.
8 Outside Telephone Cable. Filled Core. Moisture Barrier. FoamedSkin polyethylene insulation. Standards: ANSI/ICEA S808 Telecommunications cable filled, polyolefin insulated copper conductor. NTC0 Telecommunications copper conductor multipair cables, polyolefin insulated and covered, filled and dry. Note:. Data herein indicated are approximated and are subject to normal manuracturing tolerances NOMINAL PAIRS STANDARD LENGTH BY REEL (m) TOTAL WEIGTH (kg/km) OVERALL SPARE PAIRS CONDUCTOR JACKET TOTAL WEIGTH (kg/km)
9 Outside Telephone Cable Air Core. Moisture Barrier. Description Soft copper wires insulated with high density polyethylene, foam skin or solid. Air core, conformed by groups of pairs or by unit of groups of pairs. Aluminum shield and external jacket in polyethylene type moisture barrier. Construction Conductor Soft copper wires Insulation Foam skin or solid high density polyethylene. Twisted Pairs Insulated conductors are twisted into pairs Core Assembly Up to 0 pairs, groups of 0 pairs, from 00 to pairs groups of pairs, from 0 pairs and more, units of 00 pairs (each unit is conformed by groups of pairs) Spare pairs One spare pair whitered colored at the interstices of each 00 pairs unit, to guarantee nominal numbers of pairs. Identification Pairs, groups and units that conform the core, are identified by color code (Attached) Core Wrap Nonhygroscopic dielectric tape. Offers dielectric strength between core and sheath Shield Corrugated Aluminum tape both sides covered with copolymer Jacket polyethylene, abrasion, weather, and penetration to water resistant
10 Moisture Barrier Filled Core with elastomeric compound, aluminum tape both sides covered with copolymer and polyethylene external jacket, firmly bonded to external side of aluminum tape Options Manufacturing according to REA and/or Bellcore specifications Shield in Flat Aluminum tape. Armor in corrugated and copolymer covered Steel tape for direct buried and for rodent protection. Galvanized steel wires armor for vertical installations. Other Core Assemblies are available upon request. Applications Trunk cable and distribution cable networks. For use in pressurized networks. Installation in ducts or raceways CENTELSA Outside Telephone Cable, are able for voice and data transmission up to. MHz, optimizing the bandwidth of copper cables. Standards and Specifications CENTELSA Outside Telephone Cable, are manufactured under the following standards: ANSI/ICEA S8 Telecommunications cable aircore, polyolefin insulated copper conductor. NTC0 Telecommunications copper conductor multipair cables, polyolefin insulated and covered, filled and dry. Certifications CENTELSA Outside Telephone Cable, are certified by: ICONTEC (Colombia). Standard NTC 0. Note: Other configurations, sizes, colors and length not specified herein are available upon request.
11 Note:. Data herein indicated are approximated and are subject to normal manuracturing tolerances NOMINAL PAIRS STANDARD LENGTH BY REEL (m) TOTAL WEIGTH (kg/km) OVERALL SPARE PAIRS CONDUCTOR JACKET Outside Telephone Cable. Air Core. Moisture Barrier. FoamedSkin polyethylene insulation. Standards: ANSI/ICEA S8 Telecommunications cable aircore, polyolefin insulated copper conductor. NTC0 Telecommunications copper conductor multipair cables, polyolefin insulated and covered, filled and dry.
12 8 Note:. Data herein indicated are approximated and are subject to normal manuracturing tolerances. Outside Telephone Cable. Air Core. Moisture Barrier. Solid polyethylene insulation. Standards: ANSI/ICEA S8 Telecommunications cable aircore, polyolefin insulated copper conductor. NTC0 Telecommunications copper conductor multipair cables, polyolefin insulated and covered, filled and dry NOMINAL PAIRS STANDARD LENGTH BY REEL (m) TOTAL WEIGTH (kg/km) OVERALL SPARE PAIRS CONDUCTOR JACKET
13 Outside Telephone Cable Selfsupported Figure 8. Air Core. Moisture Barrier. Description Soft copper wires insulated with high density polyethylene, foam skin or solid. Air core, conformed by groups of pairs or by unit of groups of pairs. Aluminum shield, support messenger and external jacket in polyethylene type moisture barrier. Construction Conductor Soft copper wires Insulation Foam skin or solid high density polyethylene. Twisted Pairs Insulated conductors are twisted into pairs Core Assembly Up to 0 pairs, groups of 0 pairs, from 00 to pairs groups of pairs, from 0 pairs and more, units of 00 pairs (each unit is conformed by groups of pairs) Spare pairs One spare pair whitered colored at the interstices of each 00 pairs unit, to guarantee nominal numbers of pairs. Identification Pairs, groups and units that conform the core, are identified by color code (Attached) Core Wrap Nonhygroscopic dielectric tape. Offers dielectric strength between core and sheath Shield Corrugated Aluminum tape both sides covered with copolymer Support Messenger Strand high strength galvanized steel wire. Jacket polyethylene, abrasion, weather, and penetration to water resistant
14 Moisture Barrier Air Core (for pressurerd systems) with elastomeric compound, aluminum flat tape both sides covered with copolymer and polyethylene external jacket, firmly bonded to external side of aluminum tape Options Manufacturing according to REA and/or Bellcore specifications Shield in corrugated Aluminum tape. Filled Core. Galvanized steel wires fully flooded for corrosion protection. Other Core Assemblies are available upon request. Applications For pressured systems overhead trunk cable and distribution cable networks. Aerial installation suspended from Messenger CENTELSA Outside Telephone Cable, are able for voice and data transmission up to. MHz, optimizing the bandwidth of copper cables. Standards and Specifications CENTELSA Outside Telephone Cable Figure 8, are manufactured under the following standards: ANSI/ICEA S8 Telecommunications cable aircore, polyolefin insulated copper conductor. NTC0 Telecommunications copper conductor multipair cables, polyolefin insulated and covered, filled and dry. Certifications CENTELSA Outside Telephone Cable, are certified by: ICONTEC (Colombia). Standard NTC 0. Note: Other configurations, sizes, colors and length not specified herein are available upon request. 0
15 Outside Telephone Cable. Figure 8. Air Core. Self Supported. Moisture Barrier. FoamedSkin polyethylene insulation. Standards: ANSI/ICEA S8 Telecommunications cable aircore, polyolefin insulated copper conductor. NTC0 Telecommunications copper conductor multipair cables, polyolefin insulated and covered, filled and dry. NOMINAL PAIRS SPARE PAIRS CONDUCTOR JACKET EXTERNAL DIMENSIONS 8.0 x 8.. x x..08 x..0 x.8.0 x..8 x.0 0. x.. x..0 x x. 0.0 x.. x.0. x.. x.. x.. x.0.8 x.. x 8.. x.0 STRANDS No. MESSENGER TOTAL WEIGTH (kg/km) STANDARD LENGTH BY REEL (m) 0 0 Note:. Data herein indicated are approximated and are subject to normal manuracturing tolerances.
16 Outside Telephone Cable. Figure 8. Air Core. Self Supported. Moisture Barrier. Solid polyethylene insulation. Standards: ANSI/ICEA S8 Telecommunications cable aircore, polyolefin insulated copper conductor. NTC0 Telecommunications copper conductor multipair cables, polyolefin insulated and covered, filled and dry. NOMINAL PAIRS SPARE PAIRS CONDUCTOR JACKET EXTERNAL DIMENSIONS STRANDS No. MESSENGER TOTAL WEIGTH (kg/km) STANDARD LENGTH BY REEL (m) x 8.. x x..08 x..0 x.8.0 x..8 x.0 0. x.. x..0 x 8..0 x.. x.8.8 x.. x.8. x.0. x x.. x.. x.. x Note:. Data herein indicated are approximated and are subject to normal manuracturing tolerances.
17 Outside Telephone Wire DWP Drop Wire Paralell Description Drop Wire Paralleled. Hard copper conductors or steel copper covered, polyethylene or PVC insulated. Construction Conductor Hard copper or steel copper covered (CCS) Insulation Single layer Polyethylene for DWPPE and insulation jacket integral for DWP PE, weather resistant. Polyethylene Insulation and PVC jacket for DWP PEPVC. Flame retardant PVC for DWPPVC. Paralleled conductors with polarization ridge and conductor separator membrane. Application Self supporting one pair parallel conductor Drop Wire intended for aerial service connection to the subscriber Standards CENTELSA telephone wires DWP are manufactured under the following standards: NTC Service Drop telephone wire, inside installations and jumper. Certifications CENTELSA Outside Telephone Wire, are certified by: CIDET (Colombia). Standard NTC. Package 00 or 00 meters spools in corrugated carton boxes Note: other configurations and sizes not specified in this catalogue are available upon request.
18 Outside Telephone Wire (International System Unit) Drop Wire Parallel Standards: NTC Service Drop telephone wire, inside installations and jumper. TYPE SIZE No. x AWG CONDUCTOR STRAND CROSS SECTION (mm ) MATERIAL MATERIAL AISLAMIENTO SEPARATOR JACKET EXTERNAL DIMENSIONS TOTAL WEIGTH (kg/km) DC AT 0 C (ohm/km) (Mohmkm) ONE CONDUCTOR TENSILE STRENGTH (Nominal) (MPa) DWP PVC DWP PVC CCS DWP PE CCS DWP PE DWP PE DWP PEPVC x 8 x 0 x 8 x 8 x 8 x 0 x 8 x 8 x 0 Hard Copper Hard Copper Copper Clad Steel Copper Clad Steel Hard Copper Hard Copper Hard Copper Hard Copper Hard Copper PVC PVC PVC PE PE PE PE PE PE x.. x.8. x.. x.. x.. x.8. x..0 x x Notes:. DC resistance calculated based on a 0.8 ohmcmil/ft resistivity for Hard cooper and. ohmcmil/ft for steel copper covered.. Data herein indicated are approximate and are subject to normal manufacturing tolerances. Outside Telephone Wire (International System Unit) Drop Wire Parallel Standards: NTC Service Drop telephone wire, inside installations and jumper. TYPE DWP PVC DWP PVC CCS DWP PE CCS DWP PE DWP PE DWP PEPVC SIZE No. x AWG x 8 x 0 x 8 x 8 x 8 x 0 x 8 x 8 x 0 CONDUCTOR Hard Copper Hard Copper Copper Clad Steel Copper Clad Steel Hard Copper Hard Copper Hard Copper Hard Copper Hard Copper STRAND CROSS SECTION (kcmil) MATERIAL PVC PVC PVC PE PE PE PE PE PE 8 8 SEPARATOR JACKET EXTERNAL DIMENSIONS 0 x x 0 x 0 x 0 x x x 8 8 x 0 x TOTAL WEIGTH (pound/kft) 0 DC AT 0 C (ohm/kft) (Mohm/kft) ONE CONDUCTOR TENSILE STRENGTH (Nominal) (ksi) 8 Notas:. DC resistance calculated based on a. ohmmm/km resistivity for Hard cooper and 8. ohmmm/km for steel copper covered.. Data herein indicated are approximate and are subject to normal manufacturing tolerances.
19 Outside Telephone Wire DWT Drop Wire Twisted Description Drop Wire Twisted. Hard copper conductor, individually insulated with polyethylene or PVC. Construction Conductor Hard copper Insulation Polyethylene weather resistant or flame retardat PVC. Application Self supporting one pair twisted conductor Drop Wire intended for aerial service connection to the subscriber Standards CENTELSA telephone wires DWT are manufactured under the following standards: NTC Service Drop telephone wire, inside installations and jumper. Certifications CENTELSA Outside Telephone Wire, are certified by: CIDET (Colombia). Standard NTC. Package 00 or 00 meters spools in corrugated carton boxes Note: other configurations and sizes not specified in this catalogue are available upon request.
20 Outside Telephone Wire (International System Unit) Drop Wire Twisted Standards: NTC Service Drop telephone wire, inside installations and jumper. TYPE SIZE No. x AWG STRAND CROSS SECTION (mm ) OVER EXTERNAL TOTAL WEIGTH (kg/km) DC RESISTANT AT 0 C (ohm/km) (Mohmkm) ONE CONDUCTOR TENSILE STRENGTH (Nominal) (MPa) DWT PVC DWT PVC DWT PE DWT PE x 8 x 0 x 8 x Notes:. DC resistance calculated based on a. ohmmm/km resistivity for Hard cooper.. Data herein indicated are approximate and are subject to normal manufacturing tolerances. Outside Telephone Wire Drop Wire Twisted Standards: NTC Service Drop telephone wire, inside installations and jumper. TYPE SIZE No. x AWG STRAND CROSS SECTION (kcmil) SEPARATOR EXTERNAL TOTAL WEIGTH (pound/kft) DC RESISTANT AT 0 C (ohm/kft) (Mohmkft) ONE CONDUCTOR TENSILE STRENGTH (Nominal) (ksi) DWT PVC DWT PVC DWT PE DWT PE x 8 x 0 x 8 x Notes:. DC resistance calculated based on a 0.8 ohmcmil/ft resistivity for Hard cooper.. Data herein indicated are approximate and are subject to normal manufacturing tolerances.
21 Inside Telephone Cables Description Soft copper wires insulated with flame retardant PVC, paired, unshielded or shielded with aluminum foil and drain wire, external PVC jacket. Construction Conductor Soft copper Insulation Flame retardant PVC Pairs Two insulated conductor twisted together Core Up to pairs one group of pairs, for 0 pairs and more, groups of 0 or pairs. Spare pairs One pair color coded for 0 pairs or more. Identification Pairs, groups an units in the assembly core, are identified by color code (included in this catalogue) Core Wrap Non hygroscopic polyester tape Shield Unshielded or shielded with aluminum foil and tinned copper drain wire Jacket Flame retardant PVC, gray colored. Characteristics Mutual capacitance 0 nf/km. Capacitive Unbalance 0 pf (referred to m).
22 DC Conductor Resistance.8 ohm/km. Maximum Operating Voltage 0 V. Insulation Resistance Mohmkm. Dielectric Strength (0 seg) V AC, V DC. Applications For inside residential commercial and industrial applications. Appropriate for locations with electric interference produced by near power electric circuit. Installation in dry locations in ducts trays and race ways. Standards CENTELSA Inside Cables are manufactured under the following standards: NTC8, IEC 8. Cables e hilos para bajas frecuencias con aislamiento y cubierta en PVC. Notes:. Optionally with tinned copper conductor. Other configurations and sizes not specified in this catalogue are available upon request. 8
23 Inside Unshielded Telephone Cable Standards: Low Frecuency Cables and Wire with PVC Insulation and PVC Sheat. NOMINAL PAIRS SPARE PAIRS CONDUCTOR JACKET OVERALL TOTAL WEIGTH (kg/km) STANDARD LENGTH BY REEL (m) Note: Data herein indicated are approximate and are subject to normal manufacturing tolerances. Inside Unshielded Telephone Cable Standards: Low Frecuency Cables and Wire with PVC Insulation and PVC Sheat. NOMINAL PAIRS SPARE PAIRS CONDUCTOR JACKET OVERALL TOTAL WEIGTH (kg/km) STANDARD LENGTH BY REEL (m) Note: Data herein indicated are approximate and are subject to normal manufacturing tolerances.
24 Inside Telephone Wire JWT Jumper Wire Twisted Description Twisted pair for cross connections, for inside use. Soft tinned copper insulated with PVC or PVC and Nylon, assembly in pairs, triads or quads. Construction Conductor Soft tinned copper wire Insulation Flame retardant PVC for JWT. Flame retardant PVC insulation; abrasion oil and gasoline resistant Nylon jacket for JWT PVCNY. Applications JWT: twisted telephone wire for inside use, cross connections, telephonic derivations and radio and TV equipment wiring. JWT PVCNY: connection wire in distributors, minidistributors and telephonic equipment. Nylon jacket provides abrasion resistance. JWT NY: connection wire in distributors, minidistributors and telephonic equipment. Radio and TV equipment wiring, weld able without remove the insulation, Diameter reduced tightness and low friction advantages given by Nylon insulation. Installation in dry locations, ducts or open installation. Standards CENTELSA telephone wires JWT are manufactured under the following standards: NTC Service Drop telephone wire, inside installations and jumper. 0
25 Certifications CENTELSA Outside Telephone Wire, are certified by: CIDET (Colombia). Standard NTC. Package 00 or 00 meters spools in corrugated carton boxes Note: other configurations and sizes not specified in this catalogue are available upon request. Inside Telephone Wire JWT PVC (International System Units) Jumper Wire Twisted PVC Standards: NTC Service Drop telephone wire, inside installations and jumper. SIZE AWG or mm STRAND CROSS SECTION (mm²) OVERALL EXTERNAL TOTAL WEIGTH (kg/km) DC AT 0 C¹ (ohm/km) (Mohm/km) x x x x x x x 0. x 0. x 0. x 0. x 0. x Notes:. DC resistance calculated based on a. ohmmm/km resistivity for Tinned cooper.. Data herein indicated are approximate and are subject to normal manufacturing tolerances.
26 Inside Telephone Wire JWT PVC Jumper Wire Twisted PVC Standards: NTC Service Drop telephone wire, inside installations and jumper. SIZE AWG or mm STRAND CROSS SECTION (sq inches) OVERALL EXTERNAL TOTAL WEIGTH (pound/kft) DC AT 0 C¹ (ohm/kft) (Mohm/kft) x x x x x x Notes:. DC resistance calculated based on a. ohmmm/km resistivity for Tinned cooper.. Data herein indicated are approximate and are subject to normal manufacturing tolerances. Inside Telephone Wire JWT PVCNY (International System Units) Jumper Wire Twisted PVCNylon Standards: NTC Service Drop telephone wire, inside installations and jumper. SIZE AWG or mm STRAND CROSS SECTION (mm ) NSULATION OVER JACKET OVER JACKET EXTERNAL TOTAL WEIGTH (kg/km) DC AT 0 C (ohm/km) (Mohmkm) x x x x 0. x 0. x Notes:. DC resistance calculated based on a. ohmmm/km resistivity for Tinned cooper.. Data herein indicated are approximate and are subject to normal manufacturing tolerances. Inside Telephone Wire JWT PVCNY Jumper Wire Twisted PVCNylon Standards: NTC Service Drop telephone wire, inside installations and jumper. SIZE AWG or mm STRAND CROSS SECTION (sq inches) NSULATION OVER JACKET OVER JACKET EXTERNAL TOTAL WEIGTH (kg/km) DC AT 0 C (ohm/km) (Mohmkm) x x x Notes:. DC resistance calculated based on a 0.8 ohmcmil/ft resistivity for Tinned cooper.. Data herein indicated are approximate and are subject to normal manufacturing tolerances.
27 Inside Telephone Wire JWT NY (International System Units) Jumper Wire Twisted PVCNylon Standards: NTC Service Drop telephone wire, inside installations and jumper. SIZE AWG or mm STRAND CROSS SECTION (mm²) OVER EXTERNAL TOTAL WEIGTH (kg/km) DC AT 0 C¹ (ohm/km) (Mohm/km) x x x x 0. x 0. x Notes:. DC resistance calculated based on a. ohmmm/km resistivity for Tinned cooper.. Data herein indicated are approximate and are subject to normal manufacturing tolerances. Inside Telephone Wire JWT NY Jumper Wire Twisted PVCNylon Standards: NTC Service Drop telephone wire, inside installations and jumper. SIZE AWG or mm STRAND CROSS SECTION (sq inches) OVER EXTERNAL TOTAL WEIGTH (pound/kft) DC AT 0 C¹ (ohm/kft) (Mohm/kft) x x x Notes:. DC resistance calculated based on a 0.8 ohmcmil/ft resistivity for Tinned cooper.. Data herein indicated are approximate and are subject to normal manufacturing tolerances.
28 Inside Telephone Wire JWP Jumper Wire Parallel Description Inside drop wire paralleled. Soft copper insulated with PVC. Construction Conductor Soft copper wire Insulation Flame retardant white PVC, paralleled conductors with polarization ridge. Applications Paralleled telephone wire for inside use from the interior box to exterior box; telephonic derivations. Installation in dry locations, ducts or open installation. Standards CENTELSA telephone wires JWP are manufactured under the following standards: NTC Service Drop telephone wire, inside installations and jumper. Certifications CENTELSA Outside Telephone Wire, are certified by: CIDET (Colombia). Standard NTC. Package 00 or 00 meters spools in corrugated carton boxes Note: other configurations and sizes not specified in this catalogue are available upon request.
29 Inside Telephone Wire JWP (International System Units) Jumper Wire Parallel Standards: NTC Service Drop telephone wire, inside installations and jumper. SIZE AWG or mm STRAND CROSS SECTION (mm²) EXTERNAL TOTAL WEIGTH (kg/km) DC AT 0 C¹ (ohm/km) (Mohm/km) x 0 x x.0.8 x Notes:. DC resistance calculated based on a. ohmmm/km resistivity for Soft cooper.. Data herein indicated are approximate and are subject to normal manufacturing tolerances. Inside Telephone Wire JWP Jumper Wire Parallel Standards: NTC Service Drop telephone wire, inside installations and jumper. SIZE AWG or mm STRAND CROSS SECTION (kcmil) EXTERNAL TOTAL WEIGTH (pound/kft) DC AT 0 C¹ (ohm/kft) (Mohm/kft) x 0 x x 8.. x Notes:. DC resistance calculated based on a 0. ohmcmil/ft resistivity for Soft cooper.. Data herein indicated are approximate and are subject to normal manufacturing tolerances.
30 Inside Telephone Wire JWP Jumper Wire Parallel Description Inside drop wire paralleled. Soft copper insulated with PVC. Construction Conductor Soft copper wire Insulation Flame retardant white PVC, paralleled conductors with polarization ridge. Applications Paralleled telephone wire for inside use from the interior box to exterior box; telephonic derivations. Installation in dry locations, ducts or open installation. Standards CENTELSA telephone wires JWP are manufactured under the following standards: NTC Service Drop telephone wire, inside installations and jumper. Certifications CENTELSA Outside Telephone Wire, are certified by: CIDET (Colombia). Standard NTC. Package 00 or 00 meters spools in corrugated carton boxes Note: other configurations and sizes not specified in this catalogue are available upon request.
31 Inside Telephone Wire JWP (International System Units) Jumper Wire Parallel Standards: NTC Service Drop telephone wire, inside installations and jumper. SIZE AWG or mm STRAND CROSS SECTION (mm²) EXTERNAL TOTAL WEIGTH (kg/km) DC AT 0 C¹ (ohm/km) (Mohm/km) x 0 x x.0.8 x Notes:. DC resistance calculated based on a. ohmmm/km resistivity for Soft cooper.. Data herein indicated are approximate and are subject to normal manufacturing tolerances. Inside Telephone Wire JWP Jumper Wire Parallel Standards: NTC Service Drop telephone wire, inside installations and jumper. SIZE AWG or mm STRAND CROSS SECTION (kcmil) EXTERNAL TOTAL WEIGTH (pound/kft) DC AT 0 C¹ (ohm/kft) (Mohm/kft) x 0 x x 8.. x Notes:. DC resistance calculated based on a 0. ohmcmil/ft resistivity for Soft cooper.. Data herein indicated are approximate and are subject to normal manufacturing tolerances.
32 Electrical Characteristics Outside Telephone Cables MUTUAL CAPACITANCE (nf/km) Nominal Maximum average Maximum individual 0. SIZE CAPACITIVE UNBALANCE (pf refered to m) INDIVIDUAL VALUE % OF VALUES Pair to pair (pf refered to m) Pair to shield (pf/km) 0 Frequency khz mm 0. mm CROSSTALK Power Sum db/0m ELFEXT Average 0. mm Worst Pair 0., 0. and 0. mm Average 0., 0. and 0. mm 8 8 ELNEXT Worst Pair 0., 0. and 0. mm 8 Conductor DC Resistance (ohm/km) Maximum average Maximum individual SIZE RESISTIVE UNBALANCE (%) Maximum average Maximum individual SIZE DIELECTRIC STRENGTH (Volts) SOLID POLYETHYLENE FOAM SKIN POLYETHYLENE Conductor A vs Conductor B Conductor vs Shield 000V, s V, 0s 000V, s 0V, 0s V, s V, 0s 000V, s V, 0s (Mohmkm) Filled Core Air Core 0 MAXIMUM AVERAGE ATENUATION (db/km) A Hz A 0 khz A khz SIZE Notes:. Test or value not indicated in Standard NTC 0.. Data herein indicated are subject to normal tolerances.
33 Pairs Codes in Pairs Groups Inside¹ and Outside Telephone Cables PAIRS CODES IN PAIRS GROUPS PAIR No. CONDUCTOR A COLOR CONDUCTOR B PAIR No PAIRS GROUP COLOR CODE CONDUCTOR A WHITE WHITE WHITE WHITE WHITE RED RED RED RED RED COLOR CONDUCTOR B BLUE ORANGE GREEN BROWN GREY BLUE NARANJA GREEN BROWN GREY WHITE WHITE WHITE WHITE WHITE RED RED RED RED RED BLACK BLACK BLACK BLACK BLACK YELLOW YELLOW YELLOW YELLOW YELLOW PURPLE PURPLE PURPLE PURPLE PURPLE BLUE ORANGE GREEN BROWN GREY BLUE ORANGE GREEN BROWN GREY BLUE ORANGE GREEN BROWN GREY BLUE ORANGE GREEN BROWN GREY BLUE ORANGE GREEN BROWN GREY GROUP IDENTIFICATION CONSTRUCTION GROUP No. PAIRS 0 PAIR GROUPS PAIR GROUPS 8 0 to 0 to 0 to 0 to to 0 to 0 to 0 to to 0 to to 00 0 to to 0 to to 00 0 to to to to BINDER COLOR WHITE BLUE WHITE ORANGE WHITE GREEN WHITE BROWN WHITE GREY RED BLUE RED ORANGE WHITE BLUE WHITE ORANGE WHITE GREEN WHITE BROWN WHITE GREY RED BLUE RED ORANGE RED GREEN RED BROWN RED GREY BLACK BLUE BLACK ORANGE Note:. Specifications for inside telephone cables up to 00 pairs.
34 Unit Color Code Identification Outside Telephone Cables IDENTIFICATION FOR GROUPS IN 00 PAIRS UNITS CONSTRUCTION GROUP No. BINDER COLOR PAIRS WHITE BLUE WHITE ORANGE WHITE GREEN WHITE BROWN UNITS IDENTIFICATION CONSTRUCTION UNIT No. PAIRS BINDER COLOR 00 PAIRS UNIT ( GROUPS OF PAIRS EACH) to 00 0 to 00 0 to 0 to 0 to 0 to 00 0 to 00 0 to to 00 0 to 00 to 00 0 to 00 0 to 0 to 0 to 0 to 00 0 to 00 0 to to 00 0 to to 00 0 to 00 0 to 0 to 0 WHITE BLUE WHITE ORANGE WHITE GREEN WHITE BROWN WHITE GREY RED BLUE RED ORANGE RED GREEN RED BROWN RED GREY BLACK BLUE BLACK ORANGE BLACK GREEN BLACK BROWN BLACK GREY YELLOW BLUE YELLOW ORANGE YELLOW GREEN YELLOW BROWN YELLOW GREY PURPLE BLUE PURPLE ORANGE PURPLE GREEN PURPLE BROWN 8
35 Unit Color Code Identification Outside Telephone Cables CORE ASSEMBLY IN GROUPS OR UNITS PAIRS ASSEMBLY PAIRS BY GROUP GROUPS BY UNIT (0+) (0+) (0+) (0+) (0+) (+) (0+) (+) (+) (+) (0+) (0+) (+) (+) (+) (++) (++0) (+8+) (+8+) GROUPS GROUPS GROUPS GROUPS GROUPS GROUPS GROUPS GROUPS GROUPS GROUPS UNITS UNITS UNITS UNITS UNITS UNITS UNITS UNITS UNITS
36 Assembly and Identification for Multipair Telephone Cable Core Inside¹ and Outside Telephone Cables 0 PAIRS GROUP CABLES PAIRS GROUP CABLES 0 to 0 pairs 00 to pairs 0 Pairs Assembly (0+) 00 Pairs Assembly (0+) 0 Pairs Assembly (0+) 0 Pairs Assembly (+) Pairs Assembly (0+) 00 Pairs Assembly (+) 0 Pairs Assembly (0+) Pairs Assembly (+) 0 Pairs Assembly (+) Blanco Verde Note::.Specifications for telephone cables up to 00 pairs.
37 Assembly and Identification for Multipair Telephone Cable Core Inside¹ and Outside Telephone Cables 0 Pairs Assembly (0+) Pairs Assembly (0+) 00 Pairs Assembly (+) 00 Pairs Assembly (+) 00 Pairs Assembly (+) Rojo Gris 00 PAIRS UNIT CABLES (EACH UNIT GROUPS OF PAIRS) 0 to 0 pairs Pairs Assembly (++) Orng Yellow Yellow Orng 800 Pairs Yellow Assembly (++0) 00 Pairs Assembly (+8+) Yellow Yellow Purple Yellow Yellow Yellow 0 Pairs Purple Assembly (+8+) Purple Purple Yellow Purple Yellow Yellow Yellow Yellow
Communication, Signal & Data Cables
Communication, Signal & Data Cables Used for indoor installation and interconnection of transmission, telephone, telegraph and electronic equipment as well as media equipments www.alfanar.com Communication
More informationQuality Reliability Innovation. ISO 9001 : 2000 CERTIFIED BY AFAQ No. QUAL / 1997 / 7034 a COPPER TELECOMMUNICATION CABLES
Quality Reliability Innovation ISO : CERTIFIED BY AFAQ No. QUAL / 7 / 7 a COPPER TELECOMMUNICATION CABLES COPPER TELECOMMUNICATION CABLES CONTENTS 7 NOTICE INTRODUCTION QUALITY ASSURANCE RECOMMENDED ORDERING
More informationGulf Cable & Electrical Ind. Co.
CONTENTS INTRODUCTION PRODUCT RANGE I PRODUCT DATA TABLES Irrigation 1 Coaxial s for T.V/ Satellite Antenna etc 2 Data Transmission s - 4 pair 24 AWG 3 TELEPHONE CABLES Telephone cables CCP-LAP & CCP-LAP-SS
More informationSpecializing in the cable business for over 38 years, PT. SUPREME CABLE
Specializing in the cable business for over 38 years, PT. SUPREME CABLE MANUFACTURING & COMMERCE Tbk. (PT. SUCACO Tbk) has grown steadly to become a largest and leading cable manufacturer, with international
More informationLEAD FREE FIREX. Interlock Armored Cables TECK90 and MC Industrial Cables. w w w. n e x a n s e n e r g y. c o m
FIREX Interlock Armored Cables TECK90 and MC Industrial Cables LEAD FREE O V E R 1 8 0 Y E A R S O F E X P E R I E N C E 866-663-9267 w w w. n e x a n s e n e r g y. c o m Interlock Armored Cables Introduction....2
More informationRoHS DATA, COAXIAL AND ELECTRONIC M.R. D A TA, C O A X I A L, ECOLGICAL Telecom Cables A N D EL E CTRON I C. Cables
RoHS DATA, COAXIAL AND ELECTRONIC D A TA, C O A X I A L, A N D EL E CTRON I C Cables Index SOLID MULTI-CONDUCTOR CABLES STRANDED MULTI-CONDUCTOR CABLES SPEAKER/ZIP WIRE THERMOSTAT CABLE FIRE ALARM CABLE
More informationTFC/U-JIN Coaxial Cable Product Information Sheet Type: TU6T60-JVB
Type: TU6T60-JVB Dielectric 2nd Outer (w/optional Floodant) Series 6 Coaxial Cable Copper Clad Steel Foamed Polyethylene Dielectric Bonded AP Laminate Shield 60% Aluminum Braid "Life Time" compound AP
More informationCIR. Index. Gexol. Standard CIR UL Listed Type TC-ER. Crush and Impact Resistant Without External Armoring. Arctic CIR UL Listed Type TC-ER-HL*
Gexol CIR Crush and Impact Resistant Without External Armoring Passes the same stringent crush and impact testing required by UL 2225 for Type MC-HL n Available in Standard and Arctic Grade Jackets n Highly
More informationThe National Armored Cable Manufacturers Association Presents. Installation Standard for Types AC and MC Cables
The National Armored Cable Manufacturers Association Presents Installation Standard for Types AC and MC Cables An ANSI Standard Original document jointly produced by NECA and NACMA as Standard for Installing
More informationExane 125 Drilling Rig and Commercial Marine Cable
Exane 125 Drilling Rig and Commercial Marine Cable Over 20 Years of Superior Perfomance On Oil Rigs Around The World Engineered Wire & Cable for Demanding Applications Certified as Type P per IEEE-45 STD
More informationCOAX Cables Radio Frequency Cables
COAX Cables Radio Frequency Cables Contents Page Table of contents Pictographs General information Introduction Types and abbreviations Temparature range Construction Characteristics Special constructions
More informationPROFIBUS cable. for PROFIBUS-PA and -DP 10/63-6.46 EN
for PROFIBUS-PA and -DP 10/63-6.46 EN CPN 080/CPE 080-Ex PROFIBUS-PA basis cable AWG 18, 0.88 mm 2 Use For fixed installation indoor and outdoor, on racks and in conduits. Application Fieldbus cable for
More information100% EMI Emission Containment
100% EMI Emission Containment Designed for Longer Service Life Highly Flexible for Easier Handling and Faster Installation Authorized Distributor Industrial VFD Cables Index n Variable Frequency Drive
More informationInstrumentation Cable...14-17. Power Cable...2-11. Assembly Solutions...32
Severe Cold Durability Exceeds CSA Cold Bend / Cold Impact (-0 C/-35 C) Drilling Mud Resistant Flame Retardant Certified to IEC 9-3 (33-3A) and IEEE 580 Oil Resistant Assemblies...3-33 Ester Based Mud
More informationBuilding Cables and Wires
Building Cables and Wires 4 Introduction alfanar is equipped with state-of-the-art manufacturing facilities such as latest machineries, instrumentation, quality control and testing laboratory, etc., for
More informationGexol. Gexol. The Global Cable Solutions Company. Designed for safe, reliable performance in the harshest oil and gas operating environments
Gexol Gexol World Class World Class Designed for safe, reliable performance in the harshest oil and gas operating environments Power Control Instrument VFD The Global Cable Solutions Company Gexol World
More informationSpecification SFTP CAT6 Network Cable 23AWG CU
Specification SFTP CAT6 Network Cable 23AWG CU S/FTP CAT6 Shielded S/FTP PVC Cable 23AWG 4pair Solid, Wooden drum 1000 Grey CAT6 600MHZ CM Shielded (S/FTP) Solid Cable: Our CAT6 600MHZ Shielded (S/FTP)
More informationCommercial Coaxial Cable
Commercial Coaxial Cable For the Best in COMMERCIAL TV Reception Solutions! Do you require a Digital TV reception system for your next project? Matchmaster can supply For The Best Design and supply of
More informationETHERLINE Ethernet Cable, Connectors & Tools
Ethernet Cable, ors & Tools 2 Pair 242 4 Pair 249 Industrial Ethernet ors & Tools 256 Ethernet Cable, ors & Tools ETHERNET CABLE, CONNECTORS & TOOLS Quick Select Chart 240 2 Pair 2 Pair: CAT.5/5e; Stationary
More informationIEEE POWER ENGINEERING SOCIETY CHICAGO CHAPTER THE OKONITE COMPANY WEDNESDAY JANUARY 11, 2006 JIM FITZGERALD ENGINEERING LINGO
IEEE POWER ENGINEERING SOCIETY CHICAGO CHAPTER THE OKONITE COMPANY WEDNESDAY JANUARY 11, 2006 JIM FITZGERALD ENGINEERING LINGO WHEN YOU HEAR AN ENGINEER SAY A NUMBER OF DIFFERENT APPROACHES ARE BEING IMPLEMENTED
More informationMacArtney Underwater Cables - In stock
MacArtney Underwater Cables - In stock The MacArtney Group depends on the support of a number of major cable manufacturers to supply a range of cables that are designed, manufactured and tested to meet
More informationCAVEL VS80205 MADE IN ITALY 1000 V
0,05 9,00 x 7,20 (Pet) (LSZH) Attached CE01 CE02 Sheath Colour black black red Non-migrating Polyester tape longitudinally overlapped (Pet) 25 x 23 µm Outer sheath of Thermoplastic material - black - halogen-free,
More informationKNOW YOUR OPTIONS: 230 KV POWER CABLES
KNOW YOUR OPTIONS: 230 KV POWER CABLES 71 CONDUCTOR MATERIAL AND SIZE Conductor material is a matter of both customer preference and required current carrying capacity At 230 kv, copper is most common
More informationMICROCABLES. A complete vision of your connectivity needs. Catalogue
MICROCABLES A complete vision of your connectivity needs Catalogue ELECTRONIC Filotex Introduction Application Nexans s line of microcables is designed towards the increasing requirements of electronics
More informationcoaxial cable coaxial Cable CERTIFIED 100% certified coaxial cable A cable that is marked Televés, no doubt is a certified cable
COAXIAL CABLE coaxial Cable 100% certified coaxial cable coaxial cable CERTIFIED The step ahead undertaken by Televés to improve its service and technical excellence, is now reflected in this new challenge.
More informationTECHNICAL SPECIFICATION
TECHNICAL SPECIFICATION 4 PAIR UTP CABLE (ENHANCED CATEGORY 5) PVC (CM Grade) Page 1 of 6 1. SCOPE This specification is based on the specifications of UL 444, ANSI/TIA/EIA-568-B.2, UL 1685 and covers
More informationSECTION 18370 SIGNAL WIRE AND CABLE
SECTION 18370 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for all cable and wire required for signal and signal power system wiring to wayside shelters, junction boxes, and factory
More informationSection 5 161 kv Power Cables
Know Your Options: 161 kv Power Cable 61 material and size material is a matter of both customer preference and required current carrying capacity Copper conductor common for larger loads When both copper
More informationCONFLEX ELECTRIC CABLE
CONFLEX ELECTRIC CABLE CONFLEX - 0.6/1kV Flexible VSD/EMC Cables Applications WW VSD/EMC cables are manufactured for use where electrical interference distorts signal transmission in electric motors. Standard
More informationHIGH SPEED COMMUNICATIONS PLENUM CABLE CATEGORY 5e CMP FEP JACKETED, PVC-FREE UNSHIELDED TWISTED PAIR (UTP)
Cable Specification Category 5e CMP HIGH SPEED COMMUNICATIONS PLENUM CABLE CATEGORY 5e CMP FEP JACKETED, PVC-FREE UNSHIELDED TWISTED PAIR (UTP) This cable specification complies with the electrical transmission
More informationCHARACTERISTICS AND ADVANTAGES OF OPTICAL FIBER CABLES
AND ADVANTAGES OF OPTICAL FIBER CABLES ADVANTAGES Low attenuation. Long repeater spacings or repeaterless networks. Wide bandwidth. Large transmission capacity with simultaneous voice, data and video transmission
More informationCable Products HONEYWELL SECURITY & CUSTOM ELECTRONICS. Honeywell's Genesis Series provides a full range
HONEYWELL SECURITY & CUSTOM ELECTRONICS Cable Products Honeywell's Genesis Series provides a full range of low voltage cables for security, fire, sound, voice and data, video, structured cabling and other
More informationKNOW YOUR OPTIONS: 69 KV XLPE POWER CABLE
Know Your Options: 69 kv XLPE Power Cable 3 material and size material is a matter of both customer preference and required current carrying capacity Copper conductor common for larger loads When both
More informationIndustrial Cable Solutions for Variable Frequency Drives
Industrial Cable Solutions for Variable Frequency Drives Tough challenges call for innovative solutions, and General Cable is your worldwide source for new products and a wide range of industry-leading
More informationwith coloured cores and overall copper screen UL/CSA... 17
CONTENT Cable Track Cables y SD 200 extremely flexible TPE/PUR data cable with coloured cores for continuous movement..... 6 y S 200 extremely flexible TPE/PUR control cable with numbered cores for continuous
More informationStandards Affecting a Premise T-1 Installation
Standards Affecting a Premise T-1 Installation The T-carrier system originated many years ago as a technology developed by AT&T. The intended use of the scheme was to increase the voice channel capacity
More informationPROFIBUS cable. PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications
Data Sheet 10/63-6.47-EN Rev. D PROFIBUS cable PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications PROFIBUS PA cables Non-Ex (Hazardous) applications Ex (Hazardous) applications
More informationDATA SHEET SERVO LK SMS FX8PLUS SIGNAL
Application LAPP servo cables according to Siemens * (see footnote) Standard FX8008 PLUS SIGNAL are a new generation of very highly flexible screened signal (encoder and resolver)- cables (P/Ns 00277101
More information450-750 VOLTS - Copper conductor PVC insulated SSA 1320, IEC 60227 & BS 6004 HO 7V - U With Solid Conductor - TYPE 60227 IEC 01. Insulation Thickness
450 50 VOLTS Copper conductor PVC insulated SSA 320, IEC 6022 & BS 6004 HO V U With Solid TYPE 6022 IEC 0 For internal wiring equipment rated voltage up to 000 V AC and up to 50 V to earth. Catalogue Number
More informationTECHNICAL SPECIFICATION FOR LOW-FREQUENCY CABLES AND WIRES WITH PVC INSULATION AND PVC SHEATH
Rev. 1:2007 TECHNICAL SPECIFICATION FOR LOW-FREQUENCY CABLES AND WIRES WITH PVC INSULATION AND PVC SHEATH Suruhanjaya Komunikasi dan Multimedia Malaysia Off Pesiaran Multimedia, 63000 Cyberjaya, Selangor
More informationBroadcast and Commercial AV Cabling MASTER CATALOG
Broadcast and Commercial AV Cabling MASTER CATALOG Clark Wire & Cable 408 Washington Blvd. Mundelein, IL 60060 800-222-5348 toll free 847-949-9944 local 847-949-9595 fax www.clarkwire.com Specifications
More informationCable Guide. Cables, Connectors & Tools for installation of quality networks. TRIAX - your ultimate connection
Cable Guide Cables, Connectors & Tools for installation of quality networks TRIAX - your ultimate connection A Selection of the best Triax TX Cable range optimised for digital reception Simplification
More informationFestoon 715 P PUR cable for flexible application in festoon systems
CABLES FOR CRANE AND CONVEYOR APPLICATIONS Festoon 715 P PUR cable for flexible application in festoon systems S AB BRÖCKSKES D-VIERSEN Festoon 715 P 1 x 16.0 mm 2 C Marking for Festoon 715 P 07150162:
More informationStandard Buccaneer - Ethernet
IP6 rated compliant PUR jacket on cable Shielded system shielded coupler Shroud on RJ45 Screw coupling Rewireable flex connector PCB mounted panel connector IDC termination panel connector Earth lead version
More informationPresenters Brett Weiss, Gabe Martinez, Brian Kroeger.
1 Presenters Brett Weiss, Gabe Martinez, Brian Kroeger. Topics to be covered: Cable identification Purpose of the various cable types Installation techniques Building Infrastructure Overview of networking
More information2012 CATALOG AEROSPACE VVIRE & CABLE INC. aerospacewire.com
* 2012 CATALOG AEROSPACE VVIRE & CABLE INC. A VV aerospacewire.com W e p r o u d l y m a n u f a c t u r e h i - t e m p w i r e & c a b l e. PLENUM CABLE. INDUSTRIAL CABLE. TRAY CABLE. MILITARY WIRE.
More informationUGVCL/SP/591/11KV HT AB CABLE
TECHNICAL SPECIFICATION FOR 11KV AERIAL BUNCHED CABLES FOR OVERHEAD LINES (CROSSED LINKED POLYTHENE DRY GAS CURED) 1. SCOPE This specification covers requirements of XLPE insulated, 11 KV Aerial Bunched
More informationRF & Microwave cable assemblies C291
ERTIFIED C AS 9100 RF & Microwave cable assemblies C291 B CONTENTS Pages Introduction... B-4 Specify the right cable for your application... B-5 Finder guide cables vs insertion loss... B-6 to B-7 Flexible
More informationWest Penn Wire. Access Control Systems and Cables WEST PENN WIRE CABLE WITH CONFIDENCE
West Penn Wire Access Control Systems and Cables Access Control Cables AWG Size CARD READER CABLES # of Cond. CMR Shielded CMP Shielded CMR Unshielded CMP Unshielded 22 4 3241 253241B 241 25241B 22 6 3270
More informationFire Resistant Cables
109/4 Fire Resistant Cables SR 114H Standard - SR 114E Enhanced BS 5839-1 BS 7629-1 BS 6387 BS 8434-1/2 BS 6425 BS 7622 EN 50200 World-wide recognized high quality cables Firecel SR114 are used in: Data
More informationCopper Cables CONNECTIVITY & CABLING SYSTEM
Copper Cables CONNECTIVITY & CABLING SYSTEM Category 5E M0502057-91 EN CPR 6707 U/UTP tested up to 200 MHz U/UTP CAT5E, unshielded 4-pair cable (100 Ohm), with PVC or LSZH (Low Smoke Zero Halogen) outer
More informationDIVISION 26 - ELECTRICAL SECTION 26 05 20 CABLES FOR INSTRUMENTATION
DIVISION 26 - ELECTRICAL PART 1 - GENERAL 1.01 SUMMARY A. Section Includes 1. Instrumentation Cables 1.02 SUBMITTALS A. Submit in accordance with requirements of Section 01 33 00. B. Product Data: Submit
More informationAnalog Multi-Pair Snake Cable High-Flex and NEC Rated Cables
B R I L L I A N C E B R O A D C A S T C A B L E S 19.16 High-Flex and Rated Cables Especially designed for the broadcast industry, Belden s full faily ulti-pair audio Snake cables feature options and construction
More informationUniprise Solutions COAX 101. White Paper. www.commscope.com
Uniprise Solutions COAX 101 White Paper www.commscope.com Structured cable systems have very thorough standards for fiber optic and twisted pair installations. The cabling components and installed systems
More informationCable Solutions for Servo and Variable Frequency Drives (VFD)
Cable Solutions for Servo and Variable Frequency Drives (VFD) Electric drive systems with continuous torque and speed control are widespread today. They allow an optimal adjustment of the drive with respect
More informationOutdoor Carrier Class Shielded Ethernet Cable. Datasheet. Models: PRO, CARRIER, Connectors. Increase Performance. Extreme Weatherproof
Datasheet Outdoor Carrier Class Shielded Ethernet Cable Models: PRO, CARRIER, Connectors Increase Performance Extreme Weatherproof ESD Damage Protection Extended Cable Support 1 2Datasheet Protect your
More information1236421A5-N/3GT30G-FLEX3-75 Conector Hembra, Crimp Tipo 1.0/2.3 (PUSH-PULL), 75 Ohm. Cable:Flex 3 /75
CONECTORES COAXIALES RF 1.0/2.3 1.0/2.3 1.0/2.3 www.intersac.pe 1231111L1-002-N/5GT5G-75 Conector Macho, Crimp Tipo 1.0/2.3 (PUSH-PULL), 75 Ohm. Cable:Flex 3 /75 1236421A5-N/3GT30G-FLEX3-75 Conector Hembra,
More informationSecurity & Control Cables
Security & Control Cables Our multi-conductor cables are manufactured in a wide variety of gage sizes, shielding configurations and jacketing materials including plenum, riser and general purpose. Applications
More informationFlexible cables for submersible products
Flexible cables for submersible products Standards SUBCAB cables complies with the following general standards: IEC 6045 (general) IEC 608 class 5 (conductor) IEC 608-- CLAUSE 9 (oil resistant) IEC 608--
More informationCopper Cabling Infrastructure Offering
Copper Cabling Infrastructure Offering High-Speed Copper Cabling Systems The deployment of high speed cabling systems has been increasing rapidly as data centers enable their physical infrastructure with
More informationCables and Accessories Selection Guide
Cables and Accessories Selection Guide From data centers to robotics to patient monitoring equipment, we re committed to enabling the next generation of faster, smaller and smarter design. 3M offers an
More informationRADOX railway cables acc. to EN 50264 and EN 50306. Edition 2009
RADO railway cables acc. to EN 50264 and EN 50306 Edition 2009 Bridging our know how Interdisciplinary knowledge The HUBER+SUHNER Group is a leading international manufacturer of electrical and optical
More informationFault location on power cables. Fault location on power cables
Fault location on power cables Fault location on power cables Contents: 1. Introduction 2. Construction of power cables 3. Cable faults 01. Introduction Fault location on communication and power cables
More informationCCW Continuously Corrugated Welded Cable A RMORED CAB LE FO R HAZAR D O U S LOCATI O N S
CCW Continuously Corrugated Welded Cable A RMORED CAB LE FO R HAZAR D O U S LOCATI O N S OCTOBER 2014 CCW Servicing Industrial and Specialty Applications This catalog contains in-depth information on the
More informationSUBJECT: NO MORE 300 VOLTS IN PLTC PRINT LEGEND
Belden Electronics Division P.O. Box 1980 Richmond, Indiana 47375-1980 2200 U.S. Highway 27 South Richmond, Indiana 47374-7279 Telephone: 765 983 5200 Facsimile: 765 983 5825 SUBJECT: NO MORE 300 VOLTS
More informationCorporate Profile ROYAL. MODERN ROYAL ELECTRIC Ideal Power Solution MRE ELECTRICAL, INSTRUMENTATION & COMMUNICATION SYSTEMS
Corporate Profile MODERN ROYAL ELECTRIC Ideal Power Solution ROYAL MRE ELECTRICAL, INSTRUMENTATION & COMMUNICATION SYSTEMS MAJOR STOCKIST >>> CATHODIC PROTECTION CABLES >>> LOW VOLTAGE CABLES >>> MEDIUM
More informationFlexible Control Cables
Works photo: KUKA Flexible Control Cables A Flexible Control Cables Since generations people try to build machines and plants which shall take on different functions. To raise, sink, slide, drill, transport
More information144Fibre SM (G.652) Loose Tube Micro Lite Duct Optical Fibre Cable PRODUCT INFORMATION
Fiber Single Mode Optical Fibre 144 Nos. Sterlite Fiber ITU.T - G.652 D Maximum Cabled Fibre Attenuation db/km 1310nm : 0.36 & 1550nm : 0.23 Loose Tube Filling Jelly Fiber/Tube 24 Nos. Thixotropic jelly
More informationMagnet Wire Hermincel 200 C
Magnet Wire Hermincel 200 C Description HERMINCEL is the generic name of multipurpose Magnet Wire produced based on polyester (Amide-Imide) insulation overcoated with polyamideimide. This wire has excellent
More informationMarine & Shipboard Cable JIS C 3410(1999) IEC 60092-350, 353, 354, 376
T o t a l S o l u t i o n o f M a r i n e C a b l e Marine & Shipboard Cable JIS C 3410(1999) IEC 60092-350, 353, 354, 376 Marine & Shipboard cable Total Solution of Marine Cable JIS C 3410(1999), IEC
More informationGlobal cable expertise for rolling stock
Global cable expertise for rolling stock Global cable expertise for rolling stock Single and multicore Low voltage control cables Jumper cables HV roof cables (25 kv) rubber cables for power needs of locomotives
More information75 Ω Transmission System
NRAO NTC-DSL Laboratory Report Dynamic Spectroscopy Laboratory Report Series Report 03 September, 2006 75 Ω Transmission System Chaitali R. Parashare Department of Electrical and Computer Engineering,
More informationT A B L E T 1 T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A
T A B L E T 1 1 of 7 Tests & Inspection Cable PCUT & PCUT-A (Table T1) T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A No. Test Scale MOC Requirements G 20:10:001:01 Defined Test
More informationC 060 CCTV Coaxial Cable
C 060 CCTV Coaxial Cable These cables are used for video transmissons of CCTV applications..4...... Coaxial Cable (C 060).. Inner Conductor : Ø 0.60 mm Bare Copper.. Insulation : Ø.80 mm Gas-injected Foam
More informationGenerator DoCKInG StatIonS
Generator DOCKING STATIONS TRYSTAR Portable Power Cable Cam to cam cable extensions 2000V, 100A-400A rated to NEC table 400.5 (B) All portable power cable sold is highly flexible and UL & C-UL or CSA Listed
More informationWIRE & CABLE PRODUCTS
WIRE & CABLE PRODUCTS Parallel Speaker Wire 1 leg printed for polarity, ETL or UL Listed CM 77001 UZ1802-9B5 White 18/2 conductor (7/26) parallel speaker wire, 1 leg printed "UL NEC 800 or ETL listed"
More informationDIRECTCONNECT SERVICE
DIRECTCONNECT SERVICE PRE-ASSEMBLED: LEADS, GROUNDS AND STINGERS/WHIPS Save Time, Labor and Money Lead Stinger/Whip Stock Colors (Blue, Green, Red, Yellow) available Stocked genuine Lenco and Tweco Connectors
More informationSound, Alarm & Security Cable 7
Electronics Sound, Alarm & Security Cable 7 Index Page The sound and security industry in the United States has grown from a simple and unsophisticated business, begun some 45 years ago, to one which has
More informationHINDUSTAN PETROLEUM CORPORATION LIMITED ENGINEERING & PROJECTS GRESHAM ASSURANCE HOUSE, 2 ND FLOOR, A-1595(3) 1-A, SIR P M ROAD, FORT MUMBAI-400 001
NEW POL DEPOT AT HINDUSTAN PETROLEUM CORPORATION LIMITED ENGINEERING & S GRESHAM ASSURANCE HOUSE, 2 ND FLOOR, A-1595(3) 1-A, SIR P M ROAD, FORT MUMBAI-400 001 TECHNICAL SPECIFICATION OF XLPE, FRLS LT CABLES
More informationDrop cables. Vorstadt 32 CH, 6304 Zug Switzerland. teletronik@teletronik.com www.teletronik.com
Drop cables Vorstadt 32 CH, 6304 Zug Switzerland AG teletronik@teletronik.com www.teletronik.com Brief Introduction Teletronik RG series coaxial cable was developed to meet the increasing demand of tomorrow's
More informationAirdac CNE and SNE, 600/1000V, Polyethylene Sheath, SANS 1507, NRS 063 & NRS 017
Airdac CNE and SNE, 600/1000V, Polyethylene Sheath, SANS 1507, NRS 063 & NRS 017 Conductor: Hard Drawn Copper Conductor Class 2 Insulation: LV-XLPE Phase Color Code(SNE): Red, Black & Bare Copper Phase
More informationInternational Electrotechnical Commission Standards
International Electrotechnical Commission Standards Standard IEC 60028 IEC 60038 IEC 60050-461 IEC 60055-1 IEC 60055-2 IEC 60092-101 IEC 60092-350 IEC 60092-351 IEC 60092-352 IEC 60092-353 IEC 60092-354
More informationMEDIUM VOLTAGE CABLES Up to and including 36 KV
MEDIUM VOLTAGE CABLES Up to and including 6 KV NOTICE As this catalogue is not intendedto cover all of LIBAN CABLES SAL possibilities in special cables manufacturing, the hereafter listing of the types
More information3.6/6 kv XLPE insulated cables 5. 6/10 kv XLPE insulated cables 15. 8.7/15 kv XLPE insulated cables 25. 12/20 kv XLPE insulated cables 35
CONTENTS INTRODUCTION 1 Cable selection, cable specification, cable services CABLES Constructional data: 3.6/6 kv XLPE insulated cables 5 SECTION 1 6/10 kv XLPE insulated cables 15 SECTION 2 8.7/15 kv
More informationOFFICE OF CIVIL ENGINEERING UNITED STATES COAST GUARD WASHINGTON, D.C. APRIL 1996 MARINE CABLE, POWER AND CONTROL SPECIFICATION NO.
OFFICE OF CIVIL ENGINEERING UNITED STATES COAST GUARD WASHINGTON, D.C. APRIL 1996 MARINE CABLE, POWER AND CONTROL SPECIFICATION NO. G-SEC-390E 1. SCOPE 1.1 Purpose. This specification establishes the basic
More informationThe Quality Connection. Cable Solutions for Mobile Networks Business Unit Telecom
The Quality Connection Cable Solutions for Mobile Networks Business Unit Telecom Connection Technology for Wireless Communication Systems A consistent focus on the market, in-depth sector and product knowledge,
More informationScreened cable and data cable segregation
December 2007 Screened cable and data cable segregation Can an armoured power cable be considered a screened cable and how does this relate to power and data cable segregation? The short answer is yes;
More information6 ELECTRICAL PARAMETERS
6 ELECTRICAL PARAMETERS For power, low voltage and medium voltage cables, cross section nominal areas are calculated in taking into account several parameters as: permissible current carrying capacities
More informationCoaxial Cable 5. Electronics
Electronics Coaxial Cable 5 Index Page Coaxial Solutions Guide 86-87 88-93 RG 8/U Type 94-95 96-99 To meet the needs of today s sophisticated, high-speed, wide bandwidth electronics over long distances,
More information< SD 200 C TP Continuously flexible TPE/PUR paired data cable with coloured cores and overall copper screen... 10
CONTENT General < The Company..................................................................................... 3 Customized cables for different applications < Data / POF Cables POF-LWL and hybrid
More informationFlygt flexible cables
Flygt flexible cables Contents Standards General SUBCAB 4 Screened SUBCAB 6 Rubber cable type: NSSHÖU-J 7 Screened rubber cable type: NSSHÖU../E + ST 8 FGB screened rubber cable 9 PUR control cable 0 HCR
More informationwww.ptranscable.com We specialize in low voltage cables including: Stranded Single Cable H07V-R Flexible Single Cable H05V-K
P-trans, meaning power transistor, is a well known cable manufacturer based in Aan - Jordan. The production plant produces all sorts of high quality low tension cables and is a leader in the industry supplying
More informationThe Instrumentation Cable Experts
1 The Instrumentation Cable Experts Facilities Head office & factory 1300 Industrial Boulevard Mt Pleasant, Texas 75455, USA www.dekoroncable.com Stocking Centres USA Mt Pleasant and Houston Singapore
More informationMESSENGERS FOR AERIAL CABLE
MESSENGERS FOR AERIAL CABLE COPPERWELD - EHS, 30% CONDUCTIVITY MES(size)CUWELD Size O.D. Stranding Breaking Strength Wgt./Mft. MES1/4CUWELD 1/4".242 7 #12 5,783 lbs. 128 MES5/16CUWELD 5/16".306 7 # 10
More informationCoaxial Cables for Medium-Frequency Applications
Coaxial Cables for Medium-Frequency Applications Coaxial Cables for Medium-Frequency Applications Introduction Telecommunications technology is moving forward rapidly and the need for fast and reliable
More informationCoaxial Cable Solutions Guide
Coaxial Solutions Guide General offers a complete line of Carol Brand Coaxial s for today s sophisticated high-speed, wide-bandwidth electronics products that run over long distances with minimal signal
More informationLS Data Communication Product
www.lscable.com 2007 LS Cable, Ltd. All right reserved. This product or document is protected by copyright and distributed under licenses restricting its use, copying, distribution, and decompilation.
More informationThermocouple Wire & Cable
Thermocouple Wire & Cable TRM Ltd & MICC Ltd Temperature House 21 Sedling Road Wear Industrial Estate Washington Tyne & Wear NE38 9BZ PVC Extruded Example Applications: Permanent Sensor Fabrication, Laboratories,
More informationMicrophone and Musical Instrument Cable Overview
B R I L L I A N C E B R O A D C A S T C A B L E S 19.3 Microphone and Musical Instruent Cable Overview Flexible Microphone Cables Belden icrophone cable is used for connecting low level icrophones or usical
More informationThe Quality Connection. Cables for Data Transmission in Industrial Automation
The Quality Connection Cables for Data Transmission in Industrial Automation Product range Instrumentation- and control cables Thermocouple extension and compensating cables Power cables (low and medium
More information