Marine & Shipboard Cable JIS C 3410(1999) IEC , 353, 354, 376
|
|
- Aron Jackson
- 8 years ago
- Views:
Transcription
1 T o t a l S o l u t i o n o f M a r i n e C a b l e Marine & Shipboard Cable JIS C 3410(1999) IEC , 353, 354, 376
2 Marine & Shipboard cable Total Solution of Marine Cable JIS C 3410(1999), IEC , 353, 354, 376 TMC, a marine cable company representing Korea makes happy technology. In the fast-changing global era, when companies are repeating challenges and setbacks TMC has grown continuously creating a new paradigm in the marine cable industry in Korea. Since establishment in 1991, we have been involved in marine and other special cable business. TMC started to produce indoor optical fiber cables in 2000, and in 2005, completed the new factory in Ipjang, giving us the grandiosity of a company that is the biggest of its kind in Korea. TMC has acquired certificates from 9 classification societies around the world, and exports to many countries. A corporation marching toward the future through continuous R&D, best quality and customer service! Becoming the best brand in the world based on the management philosophy. That is the dream and vision of TMC. 02 Marine & Shipboard Cable
3 Company History July.,1991 Dec., 1998 May., 2004 Mar., 2005 Mar., 2006 May., 2006 Mar., 2007 Aug., 2007 Nov., 2007 Establishment as Seojin Industry Co., Ltd. ISO 9001 Certification by LRQA ISO Certification by LRQA Changed the name of company to TMC Co., Ltd. Selected as a supplier for DSME, Agbami FPSO Project ± Selected as Excellent Supplier for Hyundai Mipo Dockyard Co., Ltd. Received the high quality supplier Certification by DSME. Korean world-class product award 2007 Award the 700 million dollars export tower Certificates Received Type Approval Certification for the Shipboard Cables by 9 Classification (ABS, BV, CCS, DNV, GL, KR, LR, NK, RINA) Received Type Approval Certification for the NEK-606(2004) Off-shore Cables by ABS, DNV, LR Listed by ETL & Received Type Approval Certification by ABS for the Off-shore Cables Received Type Approval Certification for the PassengerShip Cables by ABS, DNV, LR, CCS Received Patent of Paint Resistant Shipboard Cable ( Patent Number ) Listed by ETL & Received Type Approval certification by ABC and DNV for the IEEE 1580 Type P Cables Received Type Approval Certification for the LNG Carrier Cables by ABS, DNV, LR Received Gost-R certification for the NEK-606(2004) Off-shore Cables by GOSSTANDART Marine & Shipboard Cable 03
4 Index of symbol Cable Designation Table 1. Symbols of number of core and main use FA- Flame retardant (IEC Cat A) T Three core for power and lighting FR- Fire resistance (IEC 60331) F Four core for power and lighting FRA- Flame retardant & Fire resistant (IEC Cat A & IEC 60331) M Multi core for control and signal S Single core for power and lighting TT Telephone and instrumentation D Double core for power and lighting P Portable or flexible Table 2. Symbols of material Sheath Armoring Protective covering Others P : EP Rubber Y : PVC C: Steel wire Y : PVC S: Common shield Y : PVC CB : Copper alloy wire -S : Individual shield C : XLPE E: Earth wire (C) : Cold type Note 1. For Telephone cable, the insulation symbols are omitted. 2. In case of copper alloy wire braid, the letter shall be CB instead of letter C. ex) : 0.6/1KV SPYCB, 0.6/1KV SPYCBY 3. In case of cable with earth wire, letter E shall be suffixed to symbol. ex) : 0.6/1kV TPYE 0.6/1kV FRA- TPYCY Voltage Fire Resistant Layer No. of (Three) (EPR) Sheath(PVC) Armor(Galvanized steel wire) Protective covering(pvc) 04 Marine & Shipboard Cable
5 JIS C 3410(1999), IEC , 353, 354, 376 Cable Type (Rated voltage) Unarmored cables Armored cables Armored & PVC Protective covered cables Page (3.6/6kV, 6/10kV, 8.7/15kV) - SPYCB TPYC SPYCBY TPYCY 7 - SPYC SPYCB SPYCY SPYCB 12 (0.6/1kV) (250V) Telephone & Instrumentation Cable (250V) (0.6/1kV) DPY DPYCY DPYCY DPYE DPYCE DPYCYE TPY TPYC TPYCY TPYE TPYCE TPYCYE FPY FPYC FPYCY 5PY 5PYC 5PYCY 6PY 6PYC 6PYCY 10PY 10PYC 10PYCY - SPYCBS SPYCBYS DPYS DPYCS DPYCYS TPYS TPYCS TPYCYS MPY MPYC MPYCY MPYE MPYCE MPYCYE MPYS MPYCS MPYCYS MPY-S MPYC-S MPYCY-S TTY TTYC TTYCY TTYS TTYCS TTYCYS TTY-S TTYC-S TTYCY-S RCOP(OS) RCOP(IS) DPNP, TPNP, FPNP SYP, SCP Marine & Shipboard Cable 05
6 Index of symbol High Voltage(3.6/6, 6/10, 8.7/15) Power Cable 3.6/6kV SPYCB(Y), FA-SPYCB(Y), TPYC(Y), FA-TPYC(Y) 6/10kV SPYCB(Y), FA-SPYCB(Y), TPYC(Y), FA-TPYC(Y) 8.7/15kV SPYCB(Y), FA-SPYCB(Y), TPYC(Y), FA-TPYC(Y) 07
7 JIS C 3410(1999), IEC , 353, 354, 376 CABLE DESIGNATION 3.6/6kV SPYCB(Y), TPYC(Y), FA-SPYCB(Y), FA-TPYC(Y) 6/10kV SPYCB(Y), TPYC(Y), FA-SPYCB(Y), FA-TPYC(Y) 8.7/15kV SPYCB(Y), TPYC(Y), FA-SPYCB(Y), FA-TPYC(Y) APPLICATION STANDARD - Design guide : IEC , Flame retardant : IEC & IEC Category A (FA-Type) - Cold bend/impact : CSA 22.2 No. 03 (-35 ) (Cold Type) - Max. conductor temperature : 90 ( 3.6/6kV,6/10kV,8.7/15kV ) CONSTRUCTION 6/10kV TPYCY Classification Code Construction Detail 1. T(S) Stranded tinned annealed copper wires as per IEC 60228, Class B 2. screen Semi-conducting layer (tape/compound) 3. P EPR as per IEC screen - Non-metallic part : Semi-conducting layer(tape/compound) - Metallic part : Copper tape. - A suitable separator tape(s) may be applied over the metallic part. - Three insulation screened conductors shall be cabled. 5. Cabling - Flame retardant & non-hygroscopic fillers may be used. - Suitable tape(s) may be applied on the cabled core. 6. Sheath Y ST2(PVC) as per IEC Armor 8. Paint C - Braid of copper alloy wires (-CB type) or galvanized steel wires (-C type). (CB) - Coverage density is minimum 90% - The red paint shall be painted uniformly on the steel wire braid - CB Type or Protective covering Type, paint is dispensable. 9. Protective covering Y - ST2 (PVC) as per IEC Outer sheath color : Red 10. Core identification 3C : Red, Yellow, Blue Note Cold type cable (-35 ) can be supplied. (Cold type abbreviation (C) is added at the end of designation.) ( 250V ) Telephone & Instrumentation Cable ( 250V ) SHIPBOARD CABLE 07
8 Index of symbol High Voltage(3.6/6, 6/10, 8.7/15) Power Cable No. of Cores 3.6/6kV SPYCB, 3.6/6kV SPYCBY No. mm 2 No./mm mm mm mm mm mm /km kg/km kg/km / / / / , / ,090 1, / ,360 1, / ,690 1, / ,990 2, / ,320 2, / ,830 3, / ,520 3, / ,250 4, / ,370 5, / ,390 6, / ,010 8, /6kV TPYC, 3.6/6kV TPYCY SPYCB SPYCBY Cable Weight Tolerance overall dia. dia. ance (Max.) approx. Toler- Strand (at 20 ) SPYCB SPYCBY Dia. overall dia. approx. TPYC TPYCY Cable Weight No. of Cores Strand (at 20 ) TPYC TPYCY Dia. Tolerance overall dia. ance (Max.) approx. approx. Toler- overall dia. No. mm 2 No./mm mm mm mm mm /km kg/km kg/km / ,620 1, / ,930 2, / ,370 2, / ,830 3, / ,370 3, / ,260 4, / ,290 5, / ,270 6, / ,310 7, / ,680 9, / ,860 11, / ,210 14, Marine & Shipboard Cable
9 JIS C 3410(1999), IEC , 353, 354, /10KV SPYCB, 6/10KV SPYCBY 16 7/ / , / ,030 1, / ,210 1, / ,490 1, / ,820 2, / ,130 2, / ,560 2, / ,980 3, / ,670 3, / ,360 4, / ,470 5, / ,430 6, / ,060 8,540 6/10KV TPYC, 6/10KV TPYCY SPYCB SPYCBY Cable Weight No. of Cores Strand (at 20 ) SPYCB SPYCBY Dia. Tolerance overall dia. ance (Max.) approx. approx. Toler- overall dia. No. mm 2 No./mm mm mm mm mm /km kg/km kg/km TPYC TPYCY Cable Weight No. of Cores Strand (at 20 ) TPYC TPYCY Dia. Tolerance overall dia. ance (Max.) approx. approx. Toler- overall dia. No. mm 2 No./mm mm mm mm mm /km kg/km kg/km / ,260 2, / ,750 3, / ,230 3, / ,800 4, / ,690 5, / ,780 6, / ,770 7, / ,860 8, / ,230 10, / ,400 12, / ,660 14,710 ( 3.6/6kV,6/10kV,8.7/15kV ) ( 250V ) Telephone & Instrumentation Cable ( 250V ) Marine & Shipboard Cable 09
10 Index of symbol 8.7/15kV SPYCB, 8.7/15kV SPYCBY / ,030 1, / ,180 1, / ,370 1, / ,650 1, / ,000 2, / ,410 2, / ,750 3, / ,200 3, / ,900 4, / ,610 4, / ,740 6, / ,710 7, / ,370 8, /15kV TPYC, 8.7/15kV TPYCY SPYCB SPYCBY Cable Weight No. of Cores Tolerance overall dia. ance (Max.) approx. approx. Toler- (at 20 ) FA-SPYCB FA-SPYCBY Strand Dia. overall dia. No. mm 2 No./mm mm mm mm mm /km kg/km kg/km TPYC TPYCY Cable Weight No. of Cores Tolerance overall dia. ance (Max.) approx. approx. Toler- (at 20 ) FA-TPYC FA-TPYCY Strand Dia. overall dia. No. mm 2 No./mm mm mm mm mm /km kg/km kg/km / ,230 3, / ,730 4, / ,350 4, / ,280 5, / ,420 7, / ,440 8, / ,580 9, / ,990 10, / ,220 13, / ,490 15, Marine & Shipboard Cable
11 JIS C 3410(1999), IEC , 353, 354, 376 ( 250V ) 0.6/1kV SPYC, SPYCY, FA-SPYC, FA-SPYCY 0.6/1kV SPYCB, SPYCBY, FA-SPYCB, FA-SPYCBY /1kV D(T,F,5,6,10)PY, FA-D(T,F,5,6,10)PY 0.6/1kV D(T,F,5,6,10)PYC, FA-D(T,F,5,6,10)PYC 0.6/1kV D(T,F,5,6,10)PYCY, FA-D(T,F,5,6,10)PYCY 0.6/1kV D(T)PYE, D(T)PYCE, D(T)PYCYE /1kV SPYCBS, FA- SPYCBYS 0.6/1kV DPYS, TPYS, FA-DPYS, FA-TPYS 0.6/1kV DPYCS, TPYCS, FA-DPYCS, FA-TPYCS 0.6/1kV DPYCYS, TPYCYS, FA-DPYCYS, FA-TPYCYS 17 ( 3.6/6kV,6/10kV,8.7/15kV ) Telephone & Instrumentation Cable ( 250V )
12 Index of symbol CABLE DESIGNATION 0.6/1kV SPYC, SPYCY, FA-SPYC, FA-SPYCY 0.6/1kV SPYCB, SPYCBY, FA-SPYCB, FA-SPYCBY APPLICATION STANDARD - Design guide : JIS C 3410(1999) - Flame retardant : IEC & IEC Category A (FA-Type) - Cold bend/impact : CSA 22.2 No. 03 (-35 ) (Cold Type) - Max. conductor temperature : 85 CONSTRUCTION Classification Code Construction Detail 1. S Stranded tinned annealed copper wires as per JIS C P EPR as per JIS C Sheath Y PVC as per JIS C Armor 5. Paint 6. Protective Covering Y C - Braid of copper alloy wires (-CB type) or galvanized steel wires (-C type). (CB) - Coverage density is minimum 90%. Note Fire resistant type ( FRA- ) & Cold type cable ( (C) ) can be supplied. - The white paint shall be painted uniformly on the steel wire braid - CB Type or Protective covering Type, paint is dispensable. - PVC as per JIS C Outer sheath color : Black 0.6/1kV SPYCBY 0.6/1kV SPYC, 0.6/1kV SPYCY, 0.6/1kV SPYCB, 0.6/1kV SPYCBY SPYC SPYCY Cable Weight (Approx.) No.of dia. over SPYCBY Cores SPYCB SPYC SPYCY Strand DIA. sheath Dia. Dia. (Max.) (Min.) SPYCB SPYCBY No. mm 2 No./mm mm mm mm mm /km km kg/km kg/km / , / , / / / / / / / / , / ,250 1, / ,510 1, / ,830 1, / ,250 2, / ,910 3, / ,680 3, Marine & Shipboard Cable
13 JIS C 3410(1999), IEC , 353, 354, 376 CABLE DESIGNATION 0.6/1kV D(T,F,5,6,10)PY, FA-D(T,F,5,6,10)PY 0.6/1kV D(T,F,5,6,10)PYC, FA-D(T,F,5,6,10)PYC 0.6/1kV D(T,F,5,6,10)PYCY, FA-D(T,F,5,6,10)PYCY 0.6/1kV D(T)PYE, D(T)PYCE, D(T)PYCYE APPLICATION STANDARD - Design guide : JIS C 3410(1999) - Flame retardant : IEC & IEC Category A (FA-Type) - Cold bend/impact : CSA 22.2 No. 03 (-35 ) (Cold Type) - Max. conductor temperature : 85 ( 3.6/6kV,6/10kV,8.7/15kV ) 0.6/1kV TPYCY CONSTRUCTION Classification Code Construction Detail 1. D(T,F,5,6,10) Stranded tinned annealed copper wires as per JIS C P EPR as per JIS C Insulated conductors shall be cabled. 3. Cabling - Flame retardant & non-hygroscopic fillers may be used. - Suitable tape(s) may be applied on the cabled core. 4. Sheath Y PVC as per JIS C Armor C 6. Paint 7. Protective Covering Y 8. Core identification - Braid of galvanized steel wires. - Coverage density is minimum 90%. Note Fire resistant type ( FRA- ) & Cold type cable ( (C) ) can be supplied. - The white paint shall be painted uniformly on the steel wire braid - Protective covering Type, paint is dispensable. - PVC as per JIS C Outer sheath color : Black No. of cores Without Earth core With Earth core 2C Black, White - 3C / 2C+E Black, White, Red Black, White, G/Y 4C / 3C+E Black, White, Red, Green Black, White, Red, G/Y 5C and over Black No. on white insulation Black No. on white insulation, G/Y ( 250V ) Telephone & Instrumentation Cable ( 250V ) Marine & Shipboard Cable 13
14 Index of symbol No.of Cores No.of Cores 0.6/1kV DPY, 0.6/1kV DPYC, 0.6/1kV DPYCY (Min.) (Min.) Cable Weight (Approx.) DPY DPYC DPYC No. mm 2 No./mm mm mm mm mm mm mm mm /km -km kg/km kg/km kg/km 1.5 7/ , / , / / / / / , / ,010 1,200 1, / ,360 1,580 1, / ,930 2,300 2, / ,550 2,960 3, / ,150 3,600 3, / ,840 4,330 4, / ,780 5,330 5, /1kV DPYE, 0.6/1kV DPYCE, 0.6/1kV DPYCYE Cable Weight (Approx.) DPYE DPYCE DPYCYE No. mm 2 No./mm mm mm mm mm mm mm mm /km -km kg/km kg/km kg/km / , / , / / / Earth 16 7 / / ,060 1,240 1, / ,390 1, / ,870 2,200 2, / ,660 3,060 3, / ,530 3,980 4,320 No.of Cores 0.6/1kV TPY, 0.6/1kV TPYC, 0.6/1kV TPYCY DPY DPYC DPYCY Tolerance Dia. ance Dia. ance Strand Toler- Toler- DIA. Dia. (Max.) DPYE DPYCE DPYCYE Tolerance Dia. ance Dia. ance Strand Toler- Toler- DIA. Dia. (Max.) TPY TPYC TPYCY Tolerance Dia. ance Dia. ance Strand Toler- Toler- DIA. Dia. (Max.) (Min.) TPY Cable Weight (Approx.) TPYC TPYCY No. mm 2 No./mm mm mm mm mm mm mm mm /km -km kg/km kg/km kg/km / , / , / / / / / ,060 1,240 1, / ,390 1,600 1, / ,870 2,200 2, / ,660 3,060 3, / ,530 3,980 4, / ,370 4,860 5, / ,340 5,870 6, / ,640 7,230 7, Marine & Shipboard Cable
15 JIS C 3410(1999), IEC , 353, 354, 376 No.of Cores 0.6/1kV TPYE, 0.6/1kV TPYCE, 0.6/1kV TPYCYE (Min.) Cable Weight (Approx.) TPYE TPYCE TPYCYE No. mm 2 No./mm mm mm mm mm mm mm mm /km -km kg/km kg/km kg/km / , / , / / / / ,120 1,250 3+Earth 25 7 / ,450 1,660 1, / ,900 2,140 2, / ,580 2,940 3, / ,630 4,050 4, / ,840 5,310 5, / ,950 6, / ,310 7,870 8, / ,080 9,700 10,340 ( 3.6/6kV,6/10kV,8.7/15kV ) No.of Cores 0.6/1kV FPY, 0.6/1kV FPYC, 0.6/1kV FPYCY TPYE TPYCE TPYCYE Tolerance Dia. ance Dia. ance Strand Toler- Toler- DIA. Dia. (Max.) FPY FPYC FPYCY Tolerance Dia. ance Dia. ance Strand Toler- Toler- DIA. Dia. (Max.) (Min.) Cable Weight (Approx.) FPY FPYC FPYCY No. mm 2 No./mm mm mm mm mm mm mm mm /km -km kg/km kg/km kg/km / , / , / / / / ,120 1, / ,450 1,660 1, / ,900 2,140 2, / ,580 2,940 3, / ,630 4, / ,840 5,310 5, / ,950 6,460 6, / ,310 7,870 8, / ,080 9,700 10,340 ( 250V ) Telephone & Instrumentation Cable ( 250V ) Marine & Shipboard Cable 15
16 Index of symbol No.of Cores 0.6/1kV 5PY, 0.6/1kV 5PYC, 0.6/1kV 5PYCY (Min.) 5PY Cable Weight (Approx.) 5PYC 5PYCY No. mm 2 No./mm mm mm mm mm mm mm mm /km -km kg/km kg/km kg/km / , / , / / / , / ,100 1,270 1,370 No.of Cores 0.6/1kV 6PY, 0.6/1kV 6PYC, 0.6/1kV 6PYCY (Min.) 6PY Cable Weight (Approx.) 6PYC 6PYCY No. mm 2 No./mm mm mm mm mm mm mm mm /km -km kg/km kg/km kg/km / , / , / / No.of Cores 0.6/1kV 10PY, 0.6/1kV 10PYC, 0.6/1kV 10PYCY 5PY 5PYC 5PYCY Tolerance Dia. ance Dia. ance Strand Toler- Toler- DIA. Dia. (Max.) 6PY 6PYC 6PYCY Tolerance Dia. ance Dia. ance Strand Toler- Toler- DIA. Dia. (Max.) 10PY 10PYC 10PYCY Tolerance Dia. ance Dia. ance Strand Toler- Toler- DIA. Dia. (Max.) (Min.) Cable Weight (Approx.) 10PY 10PYC 10PYCY No. mm 2 No./mm mm mm mm mm mm mm mm /km -km kg/km kg/km kg/km / , / , / , Marine & Shipboard Cable
17 JIS C 3410(1999), IEC , 353, 354, 376 CABLE DESIGNATION 0.6/1kV SPYCBS, FA- SPYCBS 0.6/1kV SPYCBYS, FA- SPYCBYS 0.6/1kV DPYS, TPYS, FA-DPYS, FA-TPYS 0.6/1kV DPYCS, TPYCS, FA-DPYCS, FA-TPYCS 0.6/1kV DPYCYS, TPYCYS, FA-DPYCYS, FA-TPYCYS APPLICATION STANDARD - Design guide : JIS C 3410(1999) - Flame retardant : IEC & IEC Category A (FA-Type) - Cold bend/impact : CSA 22.2 No. 03 (-35 ) (Cold Type) - Max. conductor temperature : 85 CONSTRUCTION Classification Code Construction Detail 1. S(D,T) Stranded tinned annealed copper wires as per JIS C P EPR as per JIS C Insulated conductors shall be cabled. ( 3.6/6kV,6/10kV,8.7/15kV ) ( 250V ) 3. Cabling - Flame retardant & non-hygroscopic fillers may be used. 0.6/1kV TPYCYS - Suitable tape(s) may be applied on the cabled core. 4. Common shield S Tinned copper wire braid 5. Sheath Y PVC as per JIS C Armor 7. Paint 8. Protective Covering Y 9. Core identification C Note Fire resistant type ( FRA- ) & Cold type cable ( (C) ) can be supplied. - Braid of copper alloy wires (-CB type) or galvanized steel wires (-C type). (CB) - Coverage density is minimum 90%. - The white paint shall be painted uniformly on the steel wire braid - Protective covering Type, paint is dispensable. - PVC as per JIS C Outer sheath color : Black No. of cores 1C 2C 3C Color Black Black, White Black, White, Red Telephone & Instrumentation Cable ( 250V ) Marine & Shipboard Cable 17
18 Index of symbol No.of Cores 0.6/1kV SPYCBS, 0.6/1kV SPYCBYS Strand DIA. dia. over sheath Dia. SPYCBS SPYCBYS Dia. (Max.) (Min.) Cable Weight (Approx.) SPYCBS SPYCBYS No. mm 2 No./mm mm mm mm mm mm mm /km -km kg/km kg/km / , / , / / / / / / / / ,070 1, / ,370 1, / ,660 1,820 No.of Cores 0.6/1kV DPYS, 0.6/1kV DPYCS, 0.6/1kV DPYCYS Strand DIA. Dia. DPYS DPYCS Dia. DPYCYS Dia. (Max.) (Min.) Cable Weight (Approx.) DPYS DPYCS DPYCYS No. mm 2 No./mm mm mm mm mm mm mm mm /km -km kg/km kg/km kg/km / , / , / / / / ,080 1, / , / ,480 1,730 1, / ,070 2,440 2, / ,750 3,170 3, / 2, ,360 3,820 4,170 No.of Cores 0.6/1kV TPYS, 0.6/1kV TPYCS, 0.6/1kV TPYCYS TPYS TPYCS TPYCYS Strand DIA. Dia. Dia. Dia. Tolerance Tolerance Tolerance Tolerance Tolerance Tolerance Tolerance Tolerance (Max.) (Min.) Cable Weight (Approx.) TPYS TPYCS TPYCYS No. mm 2 No./mm mm mm mm mm mm mm mm /km -km kg/km kg/km kg/km / , / , / / / / , / ,170 1,380 1, / ,520 1,750 1, / ,040 2,390 2, / ,880 3,290 3, / ,770 4,220 4, / ,630 5,120 5, Marine & Shipboard Cable
19 JIS C 3410(1999), IEC , 353, 354, 376 ( 250V ) ( 3.6/6kV,6/10kV,8.7/15kV ) 250V MPY, MPYE, FA- MPY, FA-MPYE 250V MPYC, MPYCE, FA- MPYC, FA-MPYCE 250V MPYCY, MPYCYE, FA- MPYCY, FA-MPYCYE V MPYS, FA-MPYS 250V MPYCS, FA-MPYCS 250V MPYCYS, FA-MPYCYS V MPY-S, FA-MPY-S 250V MPYC-S, FA-MPYC-S 250V MPYCY-S, FA-MPYCY-S 23 Telephone & Instrumentation Cable ( 250V )
20 Index of symbol CABLE DESIGNATION 250V MPY, MPYE, FA- MPY, FA-MPYE 250V MPYC, MPYCE, FA- MPYC, FA-MPYCE 250V MPYCY, MPYCYE, FA- MPYCY, FA-MPYCYE APPLICATION STANDARD - Design guide : JIS C 3410(1999) - Flame retardant : IEC & IEC Category A (FA-Type) - Cold bend/impact : CSA 22.2 No. 03 (-35 ) (Cold Type) - Max. conductor temperature : 85 CONSTRUCTION Classification Code Construction Detail 1. M Stranded tinned annealed copper wires as per JIS C P EPR as per JIS C Cabling - Insulated conductors shall be cabled. - Flame retardant & non-hygroscopic fillers may be used. - Suitable tape(s) may be applied on the cabled core. 4. Sheath Y PVC as per JIS C Armor C 6. Paint 7. Protective Covering Y - Braid of galvanized steel wires. - Coverage density is minimum 90%. - The white paint shall be painted uniformly on the steel wire braid - Protective covering Type, paint is dispensable. - PVC as per JIS C Outer sheath color : BlacK 8. Core identification Without Earth core Black No. on white insulation With Earth core Black No. on white insulation, G/Y 250V MPYCY Note Fire resistant type ( FRA- ) & Cold type cable ( (C) ) can be supplied. 20 Marine & Shipboard Cable
21 JIS C 3410(1999), IEC , 353, 354, 376 No.of Cores No.of Cores 250V MPY, 250V MPYC, 250V MPYCY 250V MPYE, 250V MPYCE, 250V MPYCYE (Min.) MPY MPYC MPYCY Tolerance Dia. ance Dia. ance Toler- Toler- Strand DIA. Dia. (Max.) MPYE MPYCE MPYCYE Tolerance Dia. ance Dia. ance (Max.) Toler- Toler- Strand DIA. Dia. (Min.) Cable Weight (Approx.) MPY MPYC MPYCY No. mm 2 No./mm mm mm mm mm mm mm mm /km -km kg/km kg/km kg/km / , , ,070 1, ,160 1,290 1, ,790 2,180 2,470 Cable Weight (Approx.) MPYE MPYCE MPYCYE No. mm 2 No./mm mm mm mm mm mm mm mm /km -km kg/km kg/km kg/km 2 + Earth Earth Earth Earth 1.0 7/ , Earth Earth Earth ,100 1, Earth ,100 1,300 1,480 ( 3.6/6kV,6/10kV,8.7/15kV ) ( 250V ) Telephone & Instrumentation Cable ( 250V ) Marine & Shipboard Cable 21
22 Index of symbol CABLE DESIGNATION 250V MPYS, FA-MPYS 250V MPYCS, FA-MPYCS 250V MPYCYS, FA-MPYCYS APPLICATION STANDARD - Design guide : JIS C 3410(1999) - Flame retardant : IEC & IEC Category A (FA-Type) - Cold bend/impact : CSA 22.2 No. 03 (-35 ) (Cold Type) - Max. conductor temperature : 85 CONSTRUCTION Classification Code Construction Detail 1. M Stranded tinned annealed copper wires as per JIS C P EPR as per JIS C Cabling - Insulated conductors shall be cabled. - Flame retardant & non-hygroscopic fillers may be used. - Suitable tape(s) may be applied on the cabled core. 4. Common shield S Tinned copper wire braid 5. Sheath Y PVC as per JIS C Armor C - Braid of galvanized steel wires. - Coverage density is minimum 90%. 7. Paint - The white paint shall be painted uniformly on the steel wire braid - Protective covering Type, paint is dispensable. 8. Protective Covering Y - PVC as per JIS C Outer sheath color : Black 9. Core identification Black No. on white insulation Note Fire resistant type ( FRA- ) & Cold type cable ( (C) ) can be supplied. 250V MPYCYS No.of Cores Strand 250V MPYS, 250V MPYCS, 250V MPYCYS DIA. MPYC MPYCS Dia. MPYCYS (Max.) (Min.) Cable Weight (Approx.) MPYC MPYCS MPYCYS No. mm 2 No./mm mm mm /km km kg/km kg/km kg/km / , , ,100 1, ,070 1,240 1, ,290 1,480 1, ,300 2,480 2, Marine & Shipboard Cable
23 JIS C 3410(1999), IEC , 353, 354, V MPYCY-S CABLE DESIGNATION 250V MPY-S, FA-MPY-S 250V MPYC-S, FA-MPYC-S 250V MPYCY-S, FA-MPYCY-S APPLICATION STANDARD - Design guide : JIS C 3410(1999) - Flame retardant : IEC & IEC Category A (FA-Type) - Cold bend/impact : CSA 22.2 No. 03 (-35 ) (Cold Type) - Max. conductor temperature : 85 CONSTRUCTION Classification Code Construction Detail 1. M Stranded tinned annealed copper wires as per JIS C P EPR as per JIS C Individual shield -S Tinned copper wire braid 4. Cabling - Insulated conductors shall be cabled. - Flame retardant & non-hygroscopic fillers may be used. - Suitable tape(s) may be applied on the cabled core. 5. Sheath Y PVC as per JIS C Armor C - Braid of galvanized steel wires. - Coverage density is minimum 90%. 7. Paint - The white paint shall be painted uniformly on the steel wire braid - Protective covering Type, paint is dispensable. 8. Protective Covering Y - PVC as per JIS C Outer sheath color : Black 9. Core identification Black No. on white insulation Note Fire resistant type ( FRA- ) & Cold type cable ( (C) ) can be supplied. No.of Cores Strand 250V MPY-S, 250V MPYC-S, 250V MPYCY-S DIA. MPY-S MPYC-S Dia. MPYCY-S (Max.) (Min.) Cable Weight (Approx.) MPY-S MPYC-S MPYCY-S No. mm 2 No./mm mm mm /km km kg/km kg/km kg/km / , , ,070 1, ,200 1,360 1, ,300 1,450 1, ,600 1,760 1, ,000 2,240 2, ,100 3,350 3,720 ( 3.6/6kV,6/10kV,8.7/15kV ) ( 250V ) Telephone & Instrumentation Cable ( 250V ) Marine & Shipboard Cable 23
24 Index of symbol Telephone & Instrumentation Cable Telephone & Instrumentation Cable 250V TTY, FA-TTY 250V TTYC, FA-TTYC 250V TTYCY, FA-TTYCY 250V TTYS, FA- TTYS 250V TTYCS, FA- TTYCS 250V TTYCYS, FA- TTYCYS 250V TTY-S, FA- TTY-S 250V TTYC-S, FA- TTYC-S 250V TTYCY-S, FA- TTYCY-S V RCOP(OS) V RCOP(IS) 30
25 JIS C 3410(1999), IEC , 353, 354, V TTYC CABLE DESIGNATION 250V TTY, FA-TTY 250V TTYC, FA-TTYC 250V TTYCY, FA-TTYCY APPLICATION STANDARD - Design guide : JIS C 3410(1999) - Flame retardant : IEC & IEC Category A (FA-Type) - Cold bend/impact : CSA 22.2 No. 03 (-35 ) (Cold Type) - Max. conductor temperature : 60 CONSTRUCTION Classification Code Construction Detail 1. TT Stranded plain annealed copper wires as per JIS C PVC as per JIS C Twisting Two Insulated cores shall be twisted together to form a pair 4. Cabling - Twisted pairs shall be cabled. - Flame retardant & non-hygroscopic fillers may be used. - Suitable tape(s) may be applied on the cabled core. 5. Sheath Y PVC as per JIS C Armor C - Braid of galvanized steel wires. - Coverage density is minimum 90%. 7. Paint - The white paint shall be painted uniformly on the steel wire braid - Protective covering Type, paint is dispensable. 8. Protective Covering Y - PVC as per JIS C Outer sheath color : Black 9. Core identification - Printed pair number and Alphabet letter on the white insulation. ex) 4P : (1A, 1B), (2A, 2B), (3A, 3B), (4A, 4B) - 1T, 1Q cable shall be identified by the black number on the white insulation Note Fire resistant type ( FRA- ) & Cold type cable ( (C) ) can be supplied. No.of pair, No.of Triad or Cores Quad 250V TTY, 250V TTYC, 250V TTYCY Strand DIA. TTY TTYC Dia. TTYCY (Max.) (Min.) Cable Weight (Approx.) mm 2 No./mm mm mm /km km kg/km kg/km kg/km T Q / , ,030 1,380 1, ,220 1,590 1, ,450 1,860 2, ,910 2,380 2,760 TTY TTYC TTYCY ( 3.6/6kV,6/10kV,8.7/15kV ) ( 250V ) Telephone & Instrumentation Cable ( 250V ) Marine & Shipboard Cable 25
26 Index of symbol Telephone & Instrumentation Cable CABLE DESIGNATION 250V TTYS, FA- TTYS 250V TTYCS, FA- TTYCS 250V TTYCYS, FA- TTYCYS APPLICATION STANDARD - Design guide : JIS C 3410(1999) - Flame retardant : IEC & IEC Category A (FA-Type) - Cold bend/impact : CSA 22.2 No. 03 (-35 ) (Cold Type) - Max. conductor temperature : 60 CONSTRUCTION Classification Code Construction Detail 1. TT Stranded plain annealed copper wires as per JIS C PVC as per JIS C Twisting Two Insulated cores shall be twisted together to form a pair 4. Cabling - Twisted pairs shall be cabled. - Flame retardant & non-hygroscopic fillers may be used. - Suitable tape(s) may be applied on the cabled core. 5. Common shield S Tinned copper wire braid 6. Sheath Y PVC as per JIS C Armor C - Braid of galvanized steel wires. - Coverage density is minimum 90%. 8. Paint - The white paint shall be painted uniformly on the steel wire braid - Protective covering Type, paint is dispensable. 9. Protective Covering Y - PVC as per JIS C Outer sheath color : Black 10. Core identification - Printed pair number and Alphabet letter on the white insulation ex) 4P : (1A,1B), (2A,2B), (3A,3B), (4A,4B) - 1T, 1Q cable shall be identified by the black number on the white insulation Note Fire resistant type ( FRA- ) & Cold type cable ( (C) ) can be supplied. 250V TTYCYS No.of pair, No.of Triad or Cores Quad 250V TTYS, 250V TTYCS, 250V TTYCYS Strand DIA. TTYS TTYCS Dia. TTYCYS (Max.) (Min.) Cable Weight (Approx.) TTYS TTYCS TTYCYS mm 2 No./mm mm mm /km km kg/km kg/km kg/km T Q / ,160 1, ,290 1,600 1, ,620 1,950 2, ,890 2,250 2, ,420 2,830 3, Marine & Shipboard Cable
27 JIS C 3410(1999), IEC , 353, 354, V TTYC-S CABLE DESIGNATION 250V TTY-S, FA- TTY-S 250V TTYC-S, FA- TTYC-S 250V TTYCY-S, FA- TTYCY-S APPLICATION STANDARD - Design guide : JIS C 3410(1999) - Flame retardant : IEC & IEC Category A (FA-Type) - Cold bend/impact : CSA 22.2 No. 03 (-35 ) (Cold Type) - Max. conductor temperature : 60 CONSTRUCTION Classification Code Construction Detail 1. TT Stranded plain annealed copper wires as per JIS C PVC as per JIS C Twisting Two Insulated cores shall be twisted together to form a pair 4. Individual shield -S Tinned copper wire braid 5. Cabling - Twisted pairs shall be cabled. - Flame retardant & non-hygroscopic fillers may be used. - Suitable tape(s) may be applied on the cabled core. 6. Sheath Y PVC as per JIS C Armor C - Braid of galvanized steel wires. - Coverage density is minimum 90%. 8. Paint - The white paint shall be painted uniformly on the steel wire braid - Protective covering Type, paint is dispensable. 9. Protective Covering Y - PVC as per JIS C Outer sheath color : Black 10. Core identification Printed pair number and Alphabet letter on the white insulation ex) 4P : (1A,1B), (2A,2B), (3A,3B), (4A,4B) Note Fire resistant type ( FRA- ) & Cold type cable ( (C) ) can be supplied. No.of pair, No.of Triad or Cores Quad 250V TTY-S, 250V TTYC-S, 250V TTYCY-S Strand DIA. TTY-S TTYC-S Dia. TTYCY-S (Max.) (Min.) Cable Weight (Approx.) TTY-S TTYC-S TTYCY-S mm 2 No./mm mm mm /km km kg/km kg/km kg/km ,070 1, / ,190 1,400 1, ,470 1,780 2, ,930 2,300 2, ,280 2,680 3, ,740 3,170 3, ,590 4,090 4,630 ( 3.6/6kV,6/10kV,8.7/15kV ) ( 250V ) Telephone & Instrumentation Cable ( 250V ) Marine & Shipboard Cable 27
28 Index of symbol Telephone & Instrumentation Cable CABLE DESIGNATION 250V RCOP(OS) APPLICATION STANDARD - Design guide : IEC , Flame retardant : IEC & IEC Category A - Cold bend/impact : CSA 22.2 No. 03 (-35 ) (Cold Type) - Max. conductor temperature : 90 CONSTRUCTION Classification Code Construction Detail 1. Stranded tinned annealed copper wires as per IEC 60228, Class 2 2. R EPR as per IEC Twisting Two/Three Insulated cores shall be twisted together to form a pair/triad. 4. Cabling Note Fire resistant type ( FR- ) & Cold type cable ( (C) ) can be supplied. - Twisted pairs/triads shall be cabled. - Flame retardant & non-hygroscopic fillers may be used. - Suitable tape(s) may be applied on the cabled core. 5. Collective screen (OS) - AL/PS tape + Tinned copper drain wire (0.75mm 2 ) - A suitable tape may be applied on the collective screen 6. Inner sheath C - SE1 as per IEC Armor O 8. Outer sheath P 9. Core identification - Braid of plain annealed copper wires - Coverage density is minimum 90%. - ST2 (PVC) as per IEC Outer sheath color : Grey (for Non-IS Type) or Blue (for IS Type) Printed pair/triad number and Alphabet letter on the white insulation. ex) 4P : (1A,1B), (2A,2B), (3A,3B), (4A,4B) 250V RCOP(OS) 28 Marine & Shipboard Cable
29 JIS C 3410(1999), IEC , 353, 354, 376 (PAIR TYPE) No. of Pairs 250V RCOP(OS) Strand DIA. (ca.) *. 1 Quad cable shall be twisted quad formation Dia. inner sheath Overall diameter Tolerance (Max.) (Min.) Cable Weight Approx. No. SQMM No./mm mm mm mm mm /km km kg/km 1Q P P P P P P P 1.0 7/ , P P ,040 16P ,160 19P ,300 20P ,350 24P ,590 30P ,000 37P ,310 ( 3.6/6kV,6/10kV,8.7/15kV ) ( 250V ) (TRIAD TYPE) No. of Triads 250V RCOP(OS) Strand DIA. (ca.) Dia. inner sheath Overall diameter Tolerance (Max.) (Min.) Cable Weight Approx. No. SQMM No./mm mm mm mm mm /km km kg/km 2T T T T T T T 1.0 7/ ,050 1,130 12T ,280 14T ,410 16T ,590 19T ,810 20T ,980 24T ,280 30T ,730 37T ,260 Telephone & Instrumentation Cable ( 250V ) Marine & Shipboard Cable 29
30 Index of symbol Telephone & Instrumentation Cable CABLE DESIGNATION 250V RCOP(IS) APPLICATION STANDARD - Design guide : IEC , Flame retardant : IEC & IEC Category A - Cold bend/impact : CSA 22.2 No. 03 (-35 ) (Cold Type) - Max. conductor temperature : 90 CONSTRUCTION Classification Code Construction Detail 1. Stranded tinned annealed copper wires as per IEC 60228, Class 2 2. R EPR as per IEC Twisting Two/Three Insulated cores shall be twisted together to form a pair/triad. 4. Individual screen (IS) Note Fire resistant type ( FR- ) & Cold type cable ( (C) ) can be supplied. - AL/PS tape + Tinned copper drain wire (0.75mm 2 ) - A suitable tape may be applied on the individual screen - Twisted pairs/triads shall be cabled. 5. Cabling - Flame retardant & non-hygroscopic fillers may be used. - Suitable tape(s) may be applied on the cabled core. 6. Inner sheath C - SE1 as per IEC Armor O 8. Outer sheath P 9. Core identification - Braid of plain annealed copper wires - Coverage density is minimum 90%. - ST2 (PVC) as per IEC Outer sheath color : Grey (for Non-IS Type) or Blue (for IS Type) Printed pair/triad number and Alphabet letter on the white insulation. ex) 4P : (1A,1B), (2A,2B), (3A,3B), (4A,4B) 250V RCOP(IS) 30 Marine & Shipboard Cable
31 JIS C 3410(1999), IEC , 353, 354, 376 (PAIR TYPE) No. of Pairs 250V RCOP(IS) Strand DIA. (ca.) Dia inner sheath Overall diameter Toler ance (Max.) (Min.) Cable Weight Approx. No. SQMM No./mm mm mm mm mm /km km kg/km 1P P P P P P P / , P P ,100 14P ,220 16P ,370 19P ,510 20P ,590 24P ,980 30P ,350 37P ,750 ( 3.6/6kV,6/10kV,8.7/15kV ) ( 250V ) (TRIAD TYPE) No. of Triads 250V RCOP(IS) Strand DIA. (ca.) Dia. inner sheath Overall diameter Tolerance (Max.) (Min.) Cable Weight Approx. No. SQMM No./mm mm mm mm mm /km km kg/km 1T T T T T T T ,050 10T / ,050 1,270 12T ,430 14T ,610 16T ,780 19T ,150 20T ,230 24T ,630 30T ,160 37T ,720 Telephone & Instrumentation Cable ( 250V ) Marine & Shipboard Cable 31
32 Index of symbol 0.6/1kV DPNP 0.6/1kV TPNP 0.6/1kV FPNP /1kV SYP 0.6/1kV SCP 34
33 JIS C 3410(1999), IEC , 353, 354, 376 CABLE DESIGNATION 0.6/1kV DPNP, 0.6/1kV TPNP, 0.6/1kV FPNP APPLICATION STANDARD - Design guide : JIS C 3410(1999) - Flame retardant : IEC Cold bend/impact : CSA 22.2 No. 03 (-35 ) (Cold Type) - Max. conductor temperature : 85 CONSTRUCTION Classification Code Construction Detail ( 3.6/6kV,6/10kV,8.7/15kV ) 0.6/1kV TPNP 1. D(T,F) Bunch stranded tinned annealed copper wires as per JIS C P EPR as per JIS C Cabling 4. Sheath NP 4. Core identification No.of Cores Size - Insulated conductors shall be cabled. - Suitable tape(s) may be applied on the cabled core. - PCP as per JIS C Outer sheath color : Black No. of cores 2C 3C 4C 0.6/1kV DPNP, 0.6/1kV TPNP, 0.6/1kV FPNP Diameter Color Black, White Black, White, Red Black, White, Red, Green Overall diameter DPNP, TPNP, FPNP (20 ) Weight (Approx.) mm 2 Stranding mm mm mm km kg/km / , / / , / / / / , / , / , / , / / / , / , / , / , / / ( 250V ) Telephone & Instrumentation Cable ( 250V ) Marine & Shipboard Cable 33
34 Index of symbol CABLE DESIGNATION 0.6/1kV SYP 0.6/1kV SCP APPLICATION STANDARD - Design guide : JIS C 3410(1999) - Flame retardant : IEC Cold bend/impact : CSA 22.2 No. 03 (-35 ) (Cold Type) - Max. conductor temperature : 75 (0.6/1kV SYP) 85 (0.6/1kV SCP) Construction Classification Code Construction Detail 1. S 2. Size 0.6/1kV SYP - Bunch stranded plain or tinned annealed copper wires as per JIS C A suitable tape may be applied on conductor. YP PVC as per JIS C CP FR-XLPE as per JIS C Diameter Overall diameter (20 ) Weight (Approx.) mm 2 Stranding mm mm mm km kg/km / / / / / / / /18/ /1kV SYP Size 0.6/1kV SCP Diameter Overall diameter (20 ) Weight (Approx.) mm 2 Stranding mm mm mm km kg/km / / / / / /18/ /28/ /39/ /21/ /19/ /25/ , Marine & Shipboard Cable
Traveling Cable for Crane. www.tmc-cable.com. www.tmc-cable.com
Head Office / Ipjang Factory 443, Yeongok-gil, Ipjang-myeon, Seobuk-gu, Cheonan-si, Chungcheongnam-do, Korea Tel. +82-41-589-6500 Fax. +82-41-589-6400 Bukmyeon Factory 5, Myungduk 1-gil, Buk-myeon, Dongnam-gu,
More informationSpecializing in the cable business for over 38 years, PT. SUPREME CABLE
Specializing in the cable business for over 38 years, PT. SUPREME CABLE MANUFACTURING & COMMERCE Tbk. (PT. SUCACO Tbk) has grown steadly to become a largest and leading cable manufacturer, with international
More informationCommunication, Signal & Data Cables
Communication, Signal & Data Cables Used for indoor installation and interconnection of transmission, telephone, telegraph and electronic equipment as well as media equipments www.alfanar.com Communication
More informationFIRE RESISTANT CABLE CONSTRUCTION OF CABLES
FIRE RESISTANT CABLE In all fire disasters, fire smoke, heat and toxic fumes are the main obstacles to safe evacuation of a building or area. A major contribution towards overcoming these hazards is the
More informationExane 125 Drilling Rig and Commercial Marine Cable
Exane 125 Drilling Rig and Commercial Marine Cable Over 20 Years of Superior Perfomance On Oil Rigs Around The World Engineered Wire & Cable for Demanding Applications Certified as Type P per IEEE-45 STD
More informationCONFLEX ELECTRIC CABLE
CONFLEX ELECTRIC CABLE CONFLEX - 0.6/1kV Flexible VSD/EMC Cables Applications WW VSD/EMC cables are manufactured for use where electrical interference distorts signal transmission in electric motors. Standard
More informationGulf Cable & Electrical Ind. Co.
CONTENTS INTRODUCTION PRODUCT RANGE I PRODUCT DATA TABLES Irrigation 1 Coaxial s for T.V/ Satellite Antenna etc 2 Data Transmission s - 4 pair 24 AWG 3 TELEPHONE CABLES Telephone cables CCP-LAP & CCP-LAP-SS
More informationInstrumentation Cable...14-17. Power Cable...2-11. Assembly Solutions...32
Severe Cold Durability Exceeds CSA Cold Bend / Cold Impact (-0 C/-35 C) Drilling Mud Resistant Flame Retardant Certified to IEC 9-3 (33-3A) and IEEE 580 Oil Resistant Assemblies...3-33 Ester Based Mud
More informationCIR. Index. Gexol. Standard CIR UL Listed Type TC-ER. Crush and Impact Resistant Without External Armoring. Arctic CIR UL Listed Type TC-ER-HL*
Gexol CIR Crush and Impact Resistant Without External Armoring Passes the same stringent crush and impact testing required by UL 2225 for Type MC-HL n Available in Standard and Arctic Grade Jackets n Highly
More informationGexol. Gexol. The Global Cable Solutions Company. Designed for safe, reliable performance in the harshest oil and gas operating environments
Gexol Gexol World Class World Class Designed for safe, reliable performance in the harshest oil and gas operating environments Power Control Instrument VFD The Global Cable Solutions Company Gexol World
More informationwww.ptranscable.com We specialize in low voltage cables including: Stranded Single Cable H07V-R Flexible Single Cable H05V-K
P-trans, meaning power transistor, is a well known cable manufacturer based in Aan - Jordan. The production plant produces all sorts of high quality low tension cables and is a leader in the industry supplying
More informationVIPERFLEX ELECTRIC CABLE
VIPERFLEX Flexible Low Voltage Electric Cable - 0.6/1kV (Rubber insulated) H07 RN-F & H07 BN-F Single Core 2-Core 2-Core and Earth 3-Core and Earth 4-Core and Earth Multi-Core and Earth H07 RCN-F & H07
More informationCorporate Profile ROYAL. MODERN ROYAL ELECTRIC Ideal Power Solution MRE ELECTRICAL, INSTRUMENTATION & COMMUNICATION SYSTEMS
Corporate Profile MODERN ROYAL ELECTRIC Ideal Power Solution ROYAL MRE ELECTRICAL, INSTRUMENTATION & COMMUNICATION SYSTEMS MAJOR STOCKIST >>> CATHODIC PROTECTION CABLES >>> LOW VOLTAGE CABLES >>> MEDIUM
More informationwith coloured cores and overall copper screen UL/CSA... 17
CONTENT Cable Track Cables y SD 200 extremely flexible TPE/PUR data cable with coloured cores for continuous movement..... 6 y S 200 extremely flexible TPE/PUR control cable with numbered cores for continuous
More informationPROFIBUS cable. PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications
Data Sheet 10/63-6.47-EN Rev. D PROFIBUS cable PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications PROFIBUS PA cables Non-Ex (Hazardous) applications Ex (Hazardous) applications
More information100% EMI Emission Containment
100% EMI Emission Containment Designed for Longer Service Life Highly Flexible for Easier Handling and Faster Installation Authorized Distributor Industrial VFD Cables Index n Variable Frequency Drive
More informationAirdac CNE and SNE, 600/1000V, Polyethylene Sheath, SANS 1507, NRS 063 & NRS 017
Airdac CNE and SNE, 600/1000V, Polyethylene Sheath, SANS 1507, NRS 063 & NRS 017 Conductor: Hard Drawn Copper Conductor Class 2 Insulation: LV-XLPE Phase Color Code(SNE): Red, Black & Bare Copper Phase
More informationPROFIBUS cable. for PROFIBUS-PA and -DP 10/63-6.46 EN
for PROFIBUS-PA and -DP 10/63-6.46 EN CPN 080/CPE 080-Ex PROFIBUS-PA basis cable AWG 18, 0.88 mm 2 Use For fixed installation indoor and outdoor, on racks and in conduits. Application Fieldbus cable for
More informationFire Resistant Cables
109/4 Fire Resistant Cables SR 114H Standard - SR 114E Enhanced BS 5839-1 BS 7629-1 BS 6387 BS 8434-1/2 BS 6425 BS 7622 EN 50200 World-wide recognized high quality cables Firecel SR114 are used in: Data
More informationOutside Telephone Cable
Outside Telephone Cable Filled Core. Moisture Barrier. Description Soft copper wires insulated with high density polyethylene, foam skin or solid. Filled core, conformed by groups of pairs or by unit of
More informationLEAD FREE FIREX. Interlock Armored Cables TECK90 and MC Industrial Cables. w w w. n e x a n s e n e r g y. c o m
FIREX Interlock Armored Cables TECK90 and MC Industrial Cables LEAD FREE O V E R 1 8 0 Y E A R S O F E X P E R I E N C E 866-663-9267 w w w. n e x a n s e n e r g y. c o m Interlock Armored Cables Introduction....2
More informationIndustrial Cable Solutions for Variable Frequency Drives
Industrial Cable Solutions for Variable Frequency Drives Tough challenges call for innovative solutions, and General Cable is your worldwide source for new products and a wide range of industry-leading
More informationCAVEL VS80205 MADE IN ITALY 1000 V
0,05 9,00 x 7,20 (Pet) (LSZH) Attached CE01 CE02 Sheath Colour black black red Non-migrating Polyester tape longitudinally overlapped (Pet) 25 x 23 µm Outer sheath of Thermoplastic material - black - halogen-free,
More informationBRÖCKSKES D-VIERSEN PV1-F 4,0 mm BRÖCKSKES D-VIERSEN PV1-F 4,0 mm d d 2 2 C VDE-REG.-Nr. 8292 10/2009
d BRÖCKSKES BRÖCKSKES D-VIERSEN D-VIERSEN PV1-F PV1-F 4,0 mm 4,0 2 mm VDE-REG.-Nr. 2 C 8292 10/2009 s - THE COMPANY DIN EN ISO 9001 More than 60 years of experience in temperature measurement and control
More informationFestoon 715 P PUR cable for flexible application in festoon systems
CABLES FOR CRANE AND CONVEYOR APPLICATIONS Festoon 715 P PUR cable for flexible application in festoon systems S AB BRÖCKSKES D-VIERSEN Festoon 715 P 1 x 16.0 mm 2 C Marking for Festoon 715 P 07150162:
More informationCOAX Cables Radio Frequency Cables
COAX Cables Radio Frequency Cables Contents Page Table of contents Pictographs General information Introduction Types and abbreviations Temparature range Construction Characteristics Special constructions
More informationCCW Continuously Corrugated Welded Cable A RMORED CAB LE FO R HAZAR D O U S LOCATI O N S
CCW Continuously Corrugated Welded Cable A RMORED CAB LE FO R HAZAR D O U S LOCATI O N S OCTOBER 2014 CCW Servicing Industrial and Specialty Applications This catalog contains in-depth information on the
More informationUGVCL/SP/591/11KV HT AB CABLE
TECHNICAL SPECIFICATION FOR 11KV AERIAL BUNCHED CABLES FOR OVERHEAD LINES (CROSSED LINKED POLYTHENE DRY GAS CURED) 1. SCOPE This specification covers requirements of XLPE insulated, 11 KV Aerial Bunched
More informationFlygt flexible cables
Flygt flexible cables Contents Standards General SUBCAB 4 Screened SUBCAB 6 Rubber cable type: NSSHÖU-J 7 Screened rubber cable type: NSSHÖU../E + ST 8 FGB screened rubber cable 9 PUR control cable 0 HCR
More informationSpecification SFTP CAT6 Network Cable 23AWG CU
Specification SFTP CAT6 Network Cable 23AWG CU S/FTP CAT6 Shielded S/FTP PVC Cable 23AWG 4pair Solid, Wooden drum 1000 Grey CAT6 600MHZ CM Shielded (S/FTP) Solid Cable: Our CAT6 600MHZ Shielded (S/FTP)
More informationFOREWORD ONE OF THE WORLD S BIGGEST COMPANIES IN THE SECTOR.
OFFSHORE CABLES FOREWORD ONE OF THE WORLD S BIGGEST COMPANIES IN THE SECTOR. General Cable Corporation is one of the world s leading cable manufacturing companies. In its work it has contributed decisively
More informationFlexible cables for submersible products
Flexible cables for submersible products Standards SUBCAB cables complies with the following general standards: IEC 6045 (general) IEC 608 class 5 (conductor) IEC 608-- CLAUSE 9 (oil resistant) IEC 608--
More information3.6/6 kv XLPE insulated cables 5. 6/10 kv XLPE insulated cables 15. 8.7/15 kv XLPE insulated cables 25. 12/20 kv XLPE insulated cables 35
CONTENTS INTRODUCTION 1 Cable selection, cable specification, cable services CABLES Constructional data: 3.6/6 kv XLPE insulated cables 5 SECTION 1 6/10 kv XLPE insulated cables 15 SECTION 2 8.7/15 kv
More informationQuality Reliability Innovation. ISO 9001 : 2000 CERTIFIED BY AFAQ No. QUAL / 1997 / 7034 a COPPER TELECOMMUNICATION CABLES
Quality Reliability Innovation ISO : CERTIFIED BY AFAQ No. QUAL / 7 / 7 a COPPER TELECOMMUNICATION CABLES COPPER TELECOMMUNICATION CABLES CONTENTS 7 NOTICE INTRODUCTION QUALITY ASSURANCE RECOMMENDED ORDERING
More informationMICROCABLES. A complete vision of your connectivity needs. Catalogue
MICROCABLES A complete vision of your connectivity needs Catalogue ELECTRONIC Filotex Introduction Application Nexans s line of microcables is designed towards the increasing requirements of electronics
More information< SD 200 C TP Continuously flexible TPE/PUR paired data cable with coloured cores and overall copper screen... 10
CONTENT General < The Company..................................................................................... 3 Customized cables for different applications < Data / POF Cables POF-LWL and hybrid
More informationFIBER OPTIC Cables. Cable for Indoor and Outdoor & Hybrid & Marine fiber optic cables
FIBER OPTIC Cables Cable for Indoor and Outdoor & Hybrid & Marine fiber optic cables TMC Co., Ltd has been pursuing innovation in technology and products for Ship and Information & Telecommunication industry.
More informationMEDIUM VOLTAGE CABLES Up to and including 36 KV
MEDIUM VOLTAGE CABLES Up to and including 6 KV NOTICE As this catalogue is not intendedto cover all of LIBAN CABLES SAL possibilities in special cables manufacturing, the hereafter listing of the types
More informationCopper Cables CONNECTIVITY & CABLING SYSTEM
Copper Cables CONNECTIVITY & CABLING SYSTEM Category 5E M0502057-91 EN CPR 6707 U/UTP tested up to 200 MHz U/UTP CAT5E, unshielded 4-pair cable (100 Ohm), with PVC or LSZH (Low Smoke Zero Halogen) outer
More informationFlexible Control Cables
Works photo: KUKA Flexible Control Cables A Flexible Control Cables Since generations people try to build machines and plants which shall take on different functions. To raise, sink, slide, drill, transport
More informationBuilding Cables and Wires
Building Cables and Wires 4 Introduction alfanar is equipped with state-of-the-art manufacturing facilities such as latest machineries, instrumentation, quality control and testing laboratory, etc., for
More informationDATA SHEET SERVO LK SMS FX8PLUS SIGNAL
Application LAPP servo cables according to Siemens * (see footnote) Standard FX8008 PLUS SIGNAL are a new generation of very highly flexible screened signal (encoder and resolver)- cables (P/Ns 00277101
More informationETHERLINE Ethernet Cable, Connectors & Tools
Ethernet Cable, ors & Tools 2 Pair 242 4 Pair 249 Industrial Ethernet ors & Tools 256 Ethernet Cable, ors & Tools ETHERNET CABLE, CONNECTORS & TOOLS Quick Select Chart 240 2 Pair 2 Pair: CAT.5/5e; Stationary
More informationIEEE POWER ENGINEERING SOCIETY CHICAGO CHAPTER THE OKONITE COMPANY WEDNESDAY JANUARY 11, 2006 JIM FITZGERALD ENGINEERING LINGO
IEEE POWER ENGINEERING SOCIETY CHICAGO CHAPTER THE OKONITE COMPANY WEDNESDAY JANUARY 11, 2006 JIM FITZGERALD ENGINEERING LINGO WHEN YOU HEAR AN ENGINEER SAY A NUMBER OF DIFFERENT APPROACHES ARE BEING IMPLEMENTED
More informationTECHNICAL SPECIFICATION FOR LOW-FREQUENCY CABLES AND WIRES WITH PVC INSULATION AND PVC SHEATH
Rev. 1:2007 TECHNICAL SPECIFICATION FOR LOW-FREQUENCY CABLES AND WIRES WITH PVC INSULATION AND PVC SHEATH Suruhanjaya Komunikasi dan Multimedia Malaysia Off Pesiaran Multimedia, 63000 Cyberjaya, Selangor
More informationHINDUSTAN PETROLEUM CORPORATION LIMITED ENGINEERING & PROJECTS GRESHAM ASSURANCE HOUSE, 2 ND FLOOR, A-1595(3) 1-A, SIR P M ROAD, FORT MUMBAI-400 001
NEW POL DEPOT AT HINDUSTAN PETROLEUM CORPORATION LIMITED ENGINEERING & S GRESHAM ASSURANCE HOUSE, 2 ND FLOOR, A-1595(3) 1-A, SIR P M ROAD, FORT MUMBAI-400 001 TECHNICAL SPECIFICATION OF XLPE, FRLS LT CABLES
More informationCONTENT. Robot cables. page. < The company... 3. < W - worldwide... 4. < Certifications... 5. < Clientele / supplier numbers... 6
CONTENT page < The company............................................................................... 3 < W - worldwide...............................................................................
More informationLIFE-LINE Safety Cables Continuous Bending Hi-Flex Electrical Cables to Guarantee Safe Cable & Hose Carrier Systems
LIFE-LINE Safety Cables Continuous Bending Hi-Flex Electrical Cables to Guarantee Safe Cable & Hose Carrier Systems Cost-Effective Safe Reliable: LIFE-LINE Cable Carrier Systems Designed by the Experts
More informationThe Quality Connection. BETAflam Fire Resistant Safety Cables
The Quality Connection BETAflam Fire Resistant Safety Cables 2 Contact Consulting and sales Switzerland Phone +41 (0)62 288 82 82 Fax +41 (0)62 288 83 83 sales@leoni-studer.ch www.leoni-infrastructure-datacom.com
More informationImportant Information: Complete Terms and Conditions are printed on sales invoices
Important Information: Complete Terms and Conditions are printed on sales invoices Notice: L&H Group is continually working to improve and add new products to the Cable Express product range. For this
More informationTFC/U-JIN Coaxial Cable Product Information Sheet Type: TU6T60-JVB
Type: TU6T60-JVB Dielectric 2nd Outer (w/optional Floodant) Series 6 Coaxial Cable Copper Clad Steel Foamed Polyethylene Dielectric Bonded AP Laminate Shield 60% Aluminum Braid "Life Time" compound AP
More informationRemoval of EP 20 10 00 02 SP High Voltage Cable
TN 018: 2014 Technical Note For queries regarding this document standards@asa.transport.nsw.gov.au www.asa.transport.nsw.gov.au TN 018: 2014 Issued date 12 March 2014 Effective dates 12 March 2014 Subject:
More informationGlobal cable expertise for rolling stock
Global cable expertise for rolling stock Global cable expertise for rolling stock Single and multicore Low voltage control cables Jumper cables HV roof cables (25 kv) rubber cables for power needs of locomotives
More informationPVC YALITIMLI SÝNYAL VE KONTROL KABLOLARI PVC INSULATED SIGNAL AND CONTROL CABLES (VDE 0812-VDE 0814-VDE 0245)
LÝYY KABLO YAPISI: CONSTRUCTION: 1- ÝLETKEN : IEC-228 ;DIN VDE 0295;HD 383 SINIF-5 ELEKTROLÝTÝK BÜKÜLÜ BAKIR 2- YALITKAN : DIN VDE 0207 BÖLÜM-4 YI2 PVC KOMPAUND 3- YALITIM RENK : DIN 47100 4- BÜKÜM : UYGUN
More informationRADOX railway cables acc. to EN 50264 and EN 50306. Edition 2009
RADO railway cables acc. to EN 50264 and EN 50306 Edition 2009 Bridging our know how Interdisciplinary knowledge The HUBER+SUHNER Group is a leading international manufacturer of electrical and optical
More informationNetwork Standard Advice No. 1420C 9/6/2011
Network Standard Advice No. 1420C 9/6/2011 TO: Customers, Service Providers and Ausgrid Staff. Advisory Note on Changes to the Use of 11kV Cable Types. Introduction This Network Standard Advice (NSA) provides
More informationOFFICE OF CIVIL ENGINEERING UNITED STATES COAST GUARD WASHINGTON, D.C. APRIL 1996 MARINE CABLE, POWER AND CONTROL SPECIFICATION NO.
OFFICE OF CIVIL ENGINEERING UNITED STATES COAST GUARD WASHINGTON, D.C. APRIL 1996 MARINE CABLE, POWER AND CONTROL SPECIFICATION NO. G-SEC-390E 1. SCOPE 1.1 Purpose. This specification establishes the basic
More informationStandard Buccaneer - Ethernet
IP6 rated compliant PUR jacket on cable Shielded system shielded coupler Shroud on RJ45 Screw coupling Rewireable flex connector PCB mounted panel connector IDC termination panel connector Earth lead version
More informationInternational Electrotechnical Commission Standards
International Electrotechnical Commission Standards Standard IEC 60028 IEC 60038 IEC 60050-461 IEC 60055-1 IEC 60055-2 IEC 60092-101 IEC 60092-350 IEC 60092-351 IEC 60092-352 IEC 60092-353 IEC 60092-354
More informationKNOW YOUR OPTIONS: 230 KV POWER CABLES
KNOW YOUR OPTIONS: 230 KV POWER CABLES 71 CONDUCTOR MATERIAL AND SIZE Conductor material is a matter of both customer preference and required current carrying capacity At 230 kv, copper is most common
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 60502-1 Second edition 2004-04 Power cables with extruded insulation and their accessories for rated voltages from 1 kv (U m = 1,2 kv) up to 30 kv (U m = 36 kv) Part 1: Cables
More information108-93018 05 APR 2016 Rev M
Product Specification 108-93018 05 APR 2016 Rev M Copper LAN Cable 1. SCOPE 1.1. Content This specification describes the general requirements for CommScope copper LAN cable. 2. APPLICABLE DOCUMENTS The
More informationRoHS DATA, COAXIAL AND ELECTRONIC M.R. D A TA, C O A X I A L, ECOLGICAL Telecom Cables A N D EL E CTRON I C. Cables
RoHS DATA, COAXIAL AND ELECTRONIC D A TA, C O A X I A L, A N D EL E CTRON I C Cables Index SOLID MULTI-CONDUCTOR CABLES STRANDED MULTI-CONDUCTOR CABLES SPEAKER/ZIP WIRE THERMOSTAT CABLE FIRE ALARM CABLE
More informationBETAtrans. Cables and Systems for Rolling Stock. Edition 2006
BETAtrans Cables and Systems for Rolling Stock. Edition 2006 Info Consulting and Sales By Phone To ask for Information or to place an order please use the following number: +49 (0)9172-6844-11 By Fax For
More informationFlexible and safe solutions, for decades. Cables for alarmand safety systems
Flexible and safe solutions, for decades. Cables for alarmand safety systems 2 We offer the widest range of cables on the market for every kind of installation. It s all about reliability. It is always
More informationSection 5 161 kv Power Cables
Know Your Options: 161 kv Power Cable 61 material and size material is a matter of both customer preference and required current carrying capacity Copper conductor common for larger loads When both copper
More informationSCHEDULE ' A' TECHNICAL SPECIFICATION FOR 11/22/33KV H.T.XLPE POWER CABLE FOR DISTRIBUTION NETWORK IN MAHARASHTRA (SPECIFICATION NO.
SCHEDULE ' A' TECHNICAL SPECIFICATION FOR 11/22/33KV H.T.XLPE POWER CABLE FOR DISTRIBUTION NETWORK IN MAHARASHTRA (SPECIFICATION NO.MM/I/HTXLPE/2006) MAHARASHTRA STATE ELECTRICITY DISTRIBUTION CO.LTD.
More informationTri-Rated Flexible PVC Equipment Wire
Application: High temperature, flame retardant wire designed for use in the switch control, relay and instrumentation panels of power switchgear and for purposes such as internal connectors in rectifier
More informationCONTENT. Robot cables NEW. page. < The company... 3. < W - worldwide... 4. < Clientele / supplier numbers... 5. < Cables for dress package...
CONTENT page < The company............................................................................... 3 < W - worldwide...............................................................................
More informationScottishPower Distribution Cables & Equipment. Metal Theft
ScottishPower Distribution Cables & Equipment Metal Theft April 2012 As an aid to deterring to metal theft this booklet has been put together to help identify the types of utility power cables and associated
More informationPower and Wiring Cables
1 Single-Core PVC 1X...................... 1: Single-Core PVC/PVC 1Y.................. 1: Flat Twin & Flat Three Core PVC /Y........ 1: Multicore XLPE/LSF/SWA/LSF BS Control Cable.............................
More informationKNOW YOUR OPTIONS: 69 KV XLPE POWER CABLE
Know Your Options: 69 kv XLPE Power Cable 3 material and size material is a matter of both customer preference and required current carrying capacity Copper conductor common for larger loads When both
More informationMacArtney Underwater Cables - In stock
MacArtney Underwater Cables - In stock The MacArtney Group depends on the support of a number of major cable manufacturers to supply a range of cables that are designed, manufactured and tested to meet
More information450-750 VOLTS - Copper conductor PVC insulated SSA 1320, IEC 60227 & BS 6004 HO 7V - U With Solid Conductor - TYPE 60227 IEC 01. Insulation Thickness
450 50 VOLTS Copper conductor PVC insulated SSA 320, IEC 6022 & BS 6004 HO V U With Solid TYPE 6022 IEC 0 For internal wiring equipment rated voltage up to 000 V AC and up to 50 V to earth. Catalogue Number
More informationCLEVELAND CABLE LOCATIONS
A WORLD POWER IN CABLE SUPPLY THE CABLE AND ACCESSORY CATALOGUE 2011 2 CLEVELAND CABLE LOCATIONS CLEVELAND CABLE LOCATIONS 3 As is illustrated within our catalogue, we stock a comprehensive range of cables
More informationVDE-approved PVC-Control Cables
Works photo: HELUKAEL VDE-approved PVC-Control Cables VDE-approved PVC-Control Cables This certification/licency is issued according to the rules of the HAR Agreement, wherein the certification/ licency
More information1394 locking cables. Your locking cables for AVT IEEE 1394 cameras
Your locking cables for AVT IEEE 1394 cameras AVT locking cables are ideal for connection of IEEE 1394 cameras in any industrial application. The high quality cables guarantee low damping and best signal
More informationThe Instrumentation Cable Experts
1 The Instrumentation Cable Experts Facilities Head office & factory 1300 Industrial Boulevard Mt Pleasant, Texas 75455, USA www.dekoroncable.com Stocking Centres USA Mt Pleasant and Houston Singapore
More informationChemical resistance Accidental
Industrial flexible cable, insulation and outer sheath in elastomer Description Application TITANEX flexible cable is intended for installations with moving equipment, electric appliances and for building
More informationFLEXIBLE INDUSTRIAL CABLES H07RN-F TENAFLEX SR
FLEXIBLE INDUSTRIAL CABLES H07RN-F TENAFLEX SR Standards : CENELEC HD 22.4 NF C 32-102-4 DIN VDE 0282-1 and VDE 0282-4 BS 6007 and BS 6500 IEC 60245-4 Rated voltage Rated voltage: 450/750 V (Use up to
More informationENERGY. TECWATER S1BN8-F 0,6/1 kv. Cable for Water Application
ENERGY TECWATER S1BN8-F 0,6/1 kv Cable for Water Application Technical Data Electrical parameters Thermal parameters Trademark Type designation Specification Approval Application Rated voltage Maximum
More informationC 060 CCTV Coaxial Cable
C 060 CCTV Coaxial Cable These cables are used for video transmissons of CCTV applications..4...... Coaxial Cable (C 060).. Inner Conductor : Ø 0.60 mm Bare Copper.. Insulation : Ø.80 mm Gas-injected Foam
More informationOutdoor Use Waterproof I/O Connectors (Optical / Modular / Electrical) FO-BH, FO-BC, NT5, JN2 / W Series
COMPONENTS PRODUCT INFORMATION RoHS Compliant NEW Outdoor Use Waterproof I/O Connectors (Optical / Modular / Electrical) FO-BH, FO-BC, NT5, JN2 / W Series Optical FO-BH Series (Compact Type) CONNECTOR
More information6000 Series Buccaneer
Robust, instant connections for harsh environments 6000 Series Buccaneer - circular connectors that combine the ease of use of a push/pull coupling mechanism with proven environmental sealing. Available
More informationDIVISION 26 - ELECTRICAL SECTION 26 05 20 CABLES FOR INSTRUMENTATION
DIVISION 26 - ELECTRICAL PART 1 - GENERAL 1.01 SUMMARY A. Section Includes 1. Instrumentation Cables 1.02 SUBMITTALS A. Submit in accordance with requirements of Section 01 33 00. B. Product Data: Submit
More informationGulf Cable & Electrical Ind. Co.
CONTENTS INTRODUCTION PRODUCT RANGE I PRODUCT DATA TABLES XLPE INSULATED 600/1000V CABLES Two Core Cables CU/XLPE/PVC/LC/PVC/SWA/PVC 1 Three Core Cables CU/XLPE/PVC/LC/PVC/SWA/PVC 2 Four Core Cables CU/XLPE/PVC/LC/PVC/SWA/PVC
More informationCABLES FOR PHOTOVOLTAIC SOLAR ENERGY INSTALLATIONS FOR CLEAN ENERGY
CABLES FOR PHOTOVOLTAIC SOLAR ENERGY INSTALLATIONS FOR CLEAN ENERGY One Company Connecting The World POWERFUL PRESENCE PRODUCTS PERFORMANCE PEOPLE General Cable has been a wire and cable innovator for
More informationSuper-Flex Traveling Cable Type ETT/300V
Cable and Super-Flex Traveling Cable Type ETT/300V Jute center - UL listed, CSA certified, NEC/CEC compliant - Power and signal conductors Part Product Number/Size Max. Hang Length Cable Nom. OD Cable
More informationTECHNICAL SPECIFICATION OF 11 / 22 KV XLPE POWER CABLE FOR SUB-STATION
GUJARAT ENERGY TRANSMISSION CORPORATION LTD. Sardar Patel Vidyut Bhavan, Race Course, Vadodara 390 007 TECHNICAL SPECIFICATION OF 11 / 22 KV XLPE POWER CABLE FOR SUB-STATION GETCO/E/TS PCBL025/RO DT.07-03-2008
More informationThe Handbook 2013 EDITION
The Handbook 2013 EDITION Trust Als you safe Alsecure is the cable you can stake your reputation on when safety and security are critical to maintain circuit integrity for mains power, lighting, alarms,
More informationCABLE SPECIFICATION CAN CAB RJ45-SUBD9
CABLE SPECIFICATION All technical information contained in this document is the exclusive property of STI and may neither be used nor disclosed without its prior written consent. AAV 33801 1/8 Connector
More informationPressure monitoring equipment for oil-sf 6. bushings, type GOEK
Pressure monitoring equipment for oil-sf 6 bushings, type GOEK Installation and maintenance guide 5693 827-6 en, Rev. 3, 2002-01-30 This document must not be copied without our written permission, and
More informatione-mobility Special cables for electric vehicles Coroplast Fritz Müller GmbH & Co. KG Tapes Cables Cable Assemblies
www.echtzeit.com e-mobility Coroplast Fritz Müller GmbH & Co. KG Tapes Cables Cable Assemblies Special cables for electric vehicles Wittener Straße 271 D-42279 Wuppertal Phone +49(0)202.2681.228 Fax +49(0)202.2681.360
More informationCatalogue Câbles d Energie
Catalogue Câbles d Energie Conductores Tecnológicos S.A. www.contecsa.es Index Page Introduction 13 RV 14 RVMV 15 RVSV 16 RVFV 17 Conductores Tecnológicos S.A. 2 www.contecsa.es INTRODUCTION Câbles d Energie
More informationFault location on power cables. Fault location on power cables
Fault location on power cables Fault location on power cables Contents: 1. Introduction 2. Construction of power cables 3. Cable faults 01. Introduction Fault location on communication and power cables
More informationLT/HT Power & Control Cables
LT/HT Power & Control s Catalogue 2014 HT Power s upto 66kV 1.1 kv Power s 1.1 kv Copper Control s ISO-9001/ 14001/18001 Certified Certification Building customer confidence by providing a wide range of
More informationFIBRA OPTICA INTERIOR/EXTERIOR TIGHT BUFFER
FIBRA OPTICA INTERIOR/EXTERIOR TIGHT BUFFER 1. Applications - Be suitable for the cable of communication,communication device pigtail and the movable connection wire jumper wire - Short and medium distance,
More informationProduct descriptions and characteristics shown in this content have no legal effect. Nexans China has the right to change product specifications
Power Cable Product descriptions and characteristics shown in this content have no legal effect. Nexans China has the right to change product specifications without prior notice. Any unauthorized dissemination,
More informationAPPLICATION ORIENTED DESIGN OF CABLES
APPLICATION ORIENTED DESIGN OF CABLES Mrs. Rohini Bhattacharyya, Dubai cables Ltd.P. O. Box 11529,Dubai. rohinib@ducab.com Mr. Nawaf Ahmad Al Mohaideb Dubai Cables Ltd. P. O. Box 11529, Dubai. Nawaf@ducab.com
More informationNSW OFFSHORE AND SPECIAL CABLES. Cables for the future, delivered today.
NSW OFFSHORE AND SPECIAL CABLES. Cables for the future, delivered today. NORDDEUTSCHE SEEKABELWERKE GMBH (NSW) The submarine competence center within the General Cable Group NSW was founded in 1899 by
More information