1 A WORLD POWER IN CABLE SUPPLY THE CABLE AND ACCESSORY CATALOGUE 2011
2 2 CLEVELAND CABLE LOCATIONS CLEVELAND CABLE LOCATIONS
3 3 As is illustrated within our catalogue, we stock a comprehensive range of cables for every conceivable application. All types shown are considered as standard items to our range and are always available for immediate delivery. Our stocks are extremely large and unrivalled in the industry. We are fortunate to have a very experienced and dedicated team of people who are able to assist and advise. Additionally our policy of continuing investment in the best available technology, warehousing, handling and measuring equipment and delivery vehicles enables us to guarantee all our customers an extremely high quality service. CLEVELAND CABLE COMPANY Enquiries are welcome from customers worldwide. Our export service is efficient and reliable with the ability to ship by air or sea freight to any destination. Please feel free to contact the distribution centre of your choice for an immediate, professional and trouble free service. Middlesbrough Bristol Glasgow Milton Keynes London Newcastle Warrington
4 4 CLEVELAND CABLE COMPANY CLEVELAND CABLE COMPANY Cleveland Cable Company, established in 1978, is undoubtedly the foremost distributor of electrical cables in Great Britain and possibly Europe. The Head Office and principal stocking location is located at Middlesbrough in the North East of England. This site covers an area of twelve acres and includes over 160,000 square feet of warehousing. Additionally there are regional depots at Bristol, Glasgow, London, Milton Keynes, Newcastle and Warrington. Each location holds comprehensive stocks and is equipped with the most modern handling and measuring equipment. Deliveries are made by our own fleet of purpose-designed vehicles, all of which are fitted with hydraulic lifting equipment for safe offloading onsite and also efficient collection of empty drums.
5
6 MIDDLESBROUGH HEAD OFFICE - WAREHOUSES AND STOCKYARD
7 LAND ACQUIRED FOR FUTURE DEVELOPMENT MIDDLESBROUGH HEAD OFFICE - WAREHOUSES AND STOCKYARD
8 8 GLAND SELECTION GUIDELINES There are many factors to be considered when selecting cable glands for industrial installations. Neglecting to give due attention to these factors could cause unnecessary difficulties at a crucial point in time where most inconvenience and expense can result. It is most desirable to avoid discovering that, once all other equipment is on site or installed, the glands have not been ordered or are the wrong size or type. Good practice would be to allocate some planning and preparation time to cable gland selection. This will help avoid the possible disruption which could result at a critical point of the installation process. In the event of a project schedule of cables being available Cleveland Cable Company are happy to offer a gland selection and sizing service. Please contact any of our depots for further information or assistance. Here is a summary of some aspects to carefully consider when selecting cable glands. Identify the type of cable to be used. Check the construction, size and material properties of the cable. Check the type and material of the cable armour (*) Check the short circuit fault current rating of the cable armour (**) Check the actual diameter of the inner bedding (where present) against this catalogue. Check the actual diameter of the lead covering (where present) against this catalogue. Check the actual size of the overall cable diameter against this catalogue. Check the size and type or armour or braid (where present) against this catalogue. Check any special environmental requirements in relation to corrosion protection. Check the material of the mating electrical enclosures to eliminate dis-similar metals. Consider whether any protective plating is required to be applied to the cable gland. Check the type and size of the cable entry hole in the mating electrical equipment. Check the ingress protection rating of the electrical equipment or site standard. Check whether a single or double seal cable gland is required. Check whether an entry thread seal is required for IP66 (or IP67/IP68) conditions. Check whether fixing accessories such as locknuts and serrated washers are required. Check whether earth tags are required. (**) Check whether shrouds are required. Select a corresponding cable gland type from this catalogue. For installations in Hazardous Areas, special considerations should be taken into account to ensure compliance with national or international codes of practice. Check whether a thread conversion adaptor or reducer is required to make the installation. Select corresponding adaptors or reducers from this catalogue. Check whether any stopper plugs are required to close unused cable entries. Select corresponding stopper plugs from this catalogue. Note (*): If the cable armour is of a non standard material, i.e. Aluminium Wire Armour, it may be necessary to consider an alternative cable gland material, e.g. Aluminium. Note (**): For certain medium voltage and high voltage cables where the fault current carrying capacity of the cable armour is greater that that of the standard earth tag it may be necessary to consider a cable gland utilising the a heavy Cast Integral Earth Lug (CIEL) option which can be identified in the body of this catalogue.
9 9 SECTION 1 Low Voltage PVC Fixed Wiring & Mains Cables 6491X (HO7V-R) PVC insulated wiring, 1.5mm 2 630mm Bare copper strand, soft drawn to BS6360/81, 6mm 2 400mm Y PVC insulated, PVC sheathed surface wiring, 1.0mm 2 120mm *Y PVC insulated, PVC sheathed surface wiring, 1mm 2 16mm CONTENTS BS5467 Mains & control, XLPE, PVC SWA, PVC, 1.5mm 2 16mm 2 including multicores...16 BS5467 Mains, XLPE, PVC, SWA, PVC, copper conductors, 25mm 2 400mm BS5467 Mains, XLPE, PVC, SWA, MDPE, copper conductors 4mm 2 16mm BS5467 Mains, XLPE, PVC, SWA, MDPE, copper conductors 25mm 2 400mm BS5467 Mains, XLPE, PVC, SWA, PVC, aluminium conductors, 25mm 2 300mm BS7889 Mains, single core, XLPE, PVC, non-armoured, 50mm mm BS5467 Mains, single core, XLPE, PVC, aluminium wire armoured, PVC, 50mm mm Mines & Quarries Mains, XLPE, PVC, SWA, PVC, with 60% Conductivity in armour, 10mm 2 300mm EEMUA 133 Multicore, XLPE, lead sheathed, PVC, SWA, PVC, Control cable for petro-chemical industries, 1.5mm 2 4mm EEMUA 133 Mains, XLPE, lead sheathed, PVC,SWA, PVC, for petro-chemical industries, 1.5mm 2 16mm EEMUA 133 Mains, XLPE, lead sheathed, PVC, SWA, PVC, for petro-chemical industries, 25mm 2 300mm Cathodic Protection Cables. XLPE, PVC, and XLPE, PVC, SWA, PVC, 6mm 2 185mm Concentric, split & straight, single phase service cable, 4mm 2 35mm SECTION V Mains Cable BS5467 Mains, single core XLPE, PVC, aluminium wire armoured, PVC, 3300V, 120mm2 630mm BS5467 Mains three core, XLPE, PVC, SWA, PVC, 3300V, 16mm 2 400mm Mines & Quarries Mains, XLPE, PVC, SWA, PVC, with 60% conductivity in armour, 3300V, 16mm 2 300mm EEMUA 133 Mains, XLPE, Lead sheathed, PVC, SWA, PVC, for petro-chemical industries, 3300V, 25mm 2 300mm SECTION 3 LSZH Fixed Wiring & Mains Cables 6491B (H07Z-R) LSZH insulated wiring, 1.5mm 2 630mm B XLPE insulated, LSZH sheathed, surface wiring, 1.5mm 2 35mm *B XLPE insulated, LSZH sheathed surface wiring 1.5mm 2 16mm BS6724 Mains & control, XLPE, LSZH, SWA, LSZH, 1.5mm 2 16mm 2 including multicores...38 BS6724 Mains, XLPE, LSZH, SWA, LSZH, 25mm 2 400mm BS6724 Mains, single core, XLPE, LSZH, 50mm mm
10 10 CONTENTS BS6724 Mains, single core, XLPE, LSZH, aluminium wire armoured, LSZH, 50mm mm BS8436 Protected fixed wiring cable, 1mm 2 10mm SECTION 4 Medium Voltage 11000V & above BS6622 Mains, single core, XLPE, CTS, PVC, aluminium wire armoured, PVC, 11000V, 50mm 2 630mm...44 BS6622 Mains, three core, XLPE, CTS, PVC, SWA, PVC, 11000V, 25mm 2 400mm BS6622 Mains, three core, aluminium conductor XLPE, CTS, PVC, SWA, PVC, 11000V, 95mm2 300mm Triplex, BS7870, aluminium conductor XLPE, CTS,MDPE, 11000V, utility cable, 70mm 2 300mm Paper insulated, BS6480 Mains, three core, SWA, PVC, 11000V, 25mm 2 400mm BS7835 Mains, single core, XLPE, CTS, LSZH, aluminium wire armoured, LSZH, 11000V, 50mm 2 630mm BS7835 Mains, three core, XLPE, CTS, LSZH, SWA, LSZH, 11000V, 35mm 2 400mm BS7835 Mains, three core, XLPE, CTS, LSZH, SWA, LSZH, 22000V and 33000v, 95mm2 185mm SECTION 5 High voltage 33000v service and windfarm cables BS7870 Mains, single core, aluminium conductors, XLPE, CWS, MDPE, 33000v 70mm 2 630mm BS7870 Mains, single core, copper conductors, XLPE, CWS, MDPE, 33000v 70mm 2 630mm SECTION 6 Fire Protection, Alarm & Security Cables Mineral Insulated...56 BS5839/BS7629 Fire performance alarm and security cable, 1mm 2 4mm BS5839/BS7629 Enhanced fire performance alarm and security cable 1.5mm 2 4mm BS6387 Fire performance single core cable, 1.5mm 2 16mm BS6387/BS7846 Mains and control, mica tape, XLPE, LSZH,SWA, LSZH, fire resistant,1.5mm 2 16mm 2, including multicores...60 BS6387/BS7846 Mains, mica tape, XLPE, LSZH, SWA, LSZH, fire resistant, 25mm 2 400mm BS6387/BS7846 Mains and control, mica tape, XLPE, LSZH,SWA, LSZH, fire resistant, enhanced, 1.5mm 2 16mm 2, including multicores BS6387/BS7846 Mains, mica tape, XLPE, LSZH, SWA, LSZH, fire resistant, enhanced, 25mm 2 400mm
11 11 SECTION 7 Flexible Cables, PVC and Rubber PVC and LSZH flexible cables 218*Y (H03VV-F) PVC, PVC, 0.5mm mm *Y (H05VV-F) PVC, PVC, 0.5mm 2 2.5mm *Y Heat resisting PVC, PVC, 0.5mm 2 2.5mm Arctic grade low temperature flex, 1.5mm 2 6mm *B (H05ZIZI-F) LSZH, LSZH, 0.75mm 2 2.5mm YY Control cable, 0.75mm 2 1.5mm YY Control cable, 2.5mm 2 50mm SY Control cable, 0.75mm 2 2.5mm SY Control cable, 4.0mm 2 95mm CY Control cable, 0.5mm 2 16mm YY Control cable, LSZH, 0.75mm 2 25mm CY Control cable, LSZH, 0.75mm 2 1.5mm Tri-rated and Bi-rated BS6231, switchgear and control panel wire, 0.5mm 2 400mm Y PVC, PVC, 6mm 2 400mm B/6701B (H05Z-K), flexible conductor, LSZH insulated wiring, 1.5mm 2 240mm Solar Energy Cables 1.5mm 2 35mm Rubber flexible cables BS6500 EPR insulated, CSP sheathed, flexible power & control, mm BS7919 EPR insulated, CSP sheathed, flexible mains 4mm 2 16mm BS7919 EPR insulated, CSP sheathed, flexible mains, 25mm 2 630mm HO7RN-F EPR insulated, PCP sheathed, flexible mains, 1.0mm 2 50mm HO7RN-F EPR insulated, PCP sheathed, flexible mains, 70mm 2 630mm *P EPR insulated, copper braided screen, PCP sheathed, flexible mains, 1mm 2 16mm BS6500 EPR insulated, TR sheathed, flexible power & control 0.75mm 2 2.5mm Coil lead BS6195 EPR, CSP, 0.5mm 2 400mm Welding cable, O361TQ EPR, CSP, 16mm 2 185mm Flatform and silicon cables Flatform cable, PVC, PVC, 1.5mm 2 95mm Flatform cable, EPR, PCP, 1.5mm 2 70mm Silicon insulated, silicon sheathed, flexible cable, 0.75mm 2 2.5mm CONTENTS SECTION 8 Instrumentation, Control & Communication Cables BS5308 Control and instrumentation cable, non-armoured with collective screen, 0.5mm 2 1.5mm 2, part 1 and part BS5308 Control and instrumentation cable, non-armoured with individual and collective screen, 0.5mm 2 1.5mm 2, part 1 and part BS5308 Control and instrumentation cable, armoured with collective screen, 0.5mm 2 2.5mm 2, part 1 and part BS5308 Control and instrumentation cable, armoured with individual and collective screen, 0.5mm 2 1.5mm 2, part 1 and part
12 12 CONTENTS BS5308 Control and instrumentation cable, lead sheathed, armoured with collective screen, 0.75mm 2 1.5mm 2, part 1 and part BS5308 Control and instrumentation cable, lead sheathed, armoured with individual and collective screen, 0.75mm 2 1.5mm 2, part 1 and part BS5308 part 1 core identification...96 BS5308 part 2 core identification...97 British Steel specification CES20 type 134, 0.75mm British Steel specification CES20 type 143, 0.75mm CW1308 telephone cable Telephone cable to ENATS 09-6 standard...101/102/103 Utility Industry PVC Control Cables, ENATS mm ENATS 09-6 section 3.6 core identification ENATS 09-6 section 4.5 core identification Petroleum jelly filled telephone cable to CW1128, CW1128/1198 and BS Defence standard screened cable type Defence standard parts 4 & 5 core identification Thermocouple extension and compensating cable, 0.75mm Thermocouple core identification Traffic signal cable, loop feeder cable and loop detector cable...110/111 SECTION 9 Data Cables Belden equivalents Coaxial cables Cat 5 data cables Cat 6 data cables SECTION 10 Railway Cables Signalling cable types A1, A2, A3, B1 and B2, 0.75mm 2 95mm Signalling cable types C1, C2, C3, D1, D2, D3, E1, E2 and E3, 0.75mm 2 35mm Train protection warning system cable Point heater cable Axle counting cable...119/120 Datalink cable Copper trackside cable Power cables, 16mm 2 95mm Trackfeeder cables, 150mm mm SECTION 11 Marine and Offshore Cables EPR insulated, non-armoured shipwiring cable, 1.5mm 2 6mm EPR insulated, non-armoured shipwiring cable, 10mm 2 630mm EPR insulated, braided armoured shipwiring cable, 1.5mm 2 4mm EPR insulated, braided armoured shipwiring cable, 6mm 2 300mm EPR insulated, single core braided shipwiring cable, 6mm 2 630mm SECTION 12 Installation Accessories...129
13 13 FIXED WIRING AND MAINS CABLES PVC FIXED WIRING AND MAINS CABLES PVC
14 14 FIXED WIRING AND MAINS CABLES PVC 6491X (HO7V-R) PVC Stranded plain annealed compacted circular copper conductor, PVC outer sheath. Ref 6491X. Harmonised code HO7V-R. 450/750 volts grade to BS6004. Flame propagation to BS EN CCC CONDUCTOR STRANDING WEIGHT OVERALL BRASS A2 NYLON A2 CODE SIZE (MM 2 ) (MM) KG/KM DIAMETER (MM) 6491X1/ / / X2/ / / X / / X / / X / / X / / X / S X / S X / X / X / X / X / X / X / X / X / X / S X / S 50 PVC INSULATED WIRING CABLE 6491X (1.5MM 2 TO 630MM 2 ) AND BARE COPPER STRAND (6MM 2 TO 400MM 2 ) -15 to +70 C. Bending radius: up to 10mm 2-3 x overall diameter. above 25mm 2-6 x overall diameter. Standard colours available: 1.5mm 2 & 2.5mm 2 - Brown, Black, Grey, Blue, Green/Yellow, White, Orange, Turquoise, Violet, Pink. 4mm 2-630mm 2 - Brown, Black, Grey, Blue, Green/Yellow. temperatures below 0 C or above +60 C. BARE COPPER STRAND Stranded plain annealed compacted circular copper conductor, non insulated and non sheathed. 450 volts grade, soft drawn to BS6360/81. CCC CONDUCTOR STRANDING WEIGHT OVERALL CODE SIZE (MM 2 ) (MM) KG/KM DIAMETER (MM) CB / CB / CB / CB / CB / CB / CB / CB / CB / CB / CB / CB / CB / CB / to + 70 C Up to 10mm - 3 x overall diameter. Above 25mm - 6 x overall diameter.
15 15 SURFACE WIRING CABLES PVC 6181Y Plain annealed stranded circular copper conductor, single core, PVC insulated, PVC sheathed, Ref 6181 Y. 300/500 volts grade to BS6004. Brown/Grey or Blue/Grey. Flame propagation to BS EN CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND SINGLE CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER SIZE CLEAT (MM) (MM) 6181Y / / Y1/ / / Y2/ / / Y / / Y / / Y / S Y / S Y / Y / Y / Y / Y Y / FIXED WIRING AND MAINS CABLES PVC PVC INSULATED PVC SHEATHED SURFACE WIRING CABLE TYPE 6181Y (1MM 2 TO 120MM 2 ) PVC INSULATED PVC SHEATHED WIRING CABLE TYPE 624*Y (1MM 2 TO 16MM 2 ) -15 to +70 C. Bending radius: up to 10mm 2-3 x overall diameter. over 10mm 2-4 x overall diameter. temperatures below 0 C or above +60 C. SURFACE WIRING CABLES PVC 624*Y Plain annealed copper conductor, PVC insulated one, two or three cores laid flat with an uninsulated circuit protective conductor and PVC sheathed. Grey. Ref 6241/2/3Y 300/500 V to BS6004. Flame propagation to BS EN CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER (MM) (MM) 6241Y1BR 1.0 1/ X Y1/5BR 1.5 1/ X Y / X Y1/ / X Y1/5BRBR 1.5 1/ X Y2/ / X Y / X Y / X Y / X Y X Y / X Y1/ / X Y2/ / X to +70 C. Fixed 3 x overall diameter. temperatures below 0 C or above +60 C.
16 16 FIXED WIRING AND MAINS CABLES PVC MAINS AND CONTROL CABLES PVC Stranded plain annealed copper conductors, XLPE insulated, PVC bedding, galvanised steel wire armour, PVC outer sheath. Black. 600/1000 volts grade to BS5467. Flame propagation to BS EN CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND SINGLE CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER SIZE CLEAT (MM) (MM) XLPE2X1/ / / XLPE3X1/ / / XLPE4X1/ / / XLPE5X1/ / S 0.6 XLPE7X1/ / S 0.6 XLPE8X1/ / XLPE10X1/ / XLPE12X1/ / XLPE19X1/ / XLPE27X1/ / XLPE37X1/ / XLPE48X1/ / XLPE2X2/ / S 0.5 XLPE3X2/5* 2.5 7/ S 0.6 XLPE4X2/ / S 0.6 XLPE5X2/ / S 0.6 XLPE7X2/ / XLPE10X2/ / XLPE12X2/ / XLPE19X2/ / XLPE27X2/ / XLPE37X2/ / XLPE48X2/ / XLPE2X / S 0.6 XLPE3X4* 4.0 7/ S 0.6 XLPE4X / XLPE5X / XLPE7X / XLPE12X / XLPE19X / XLPE27X / XLPE2X / S 0.6 XLPE3X6* 6.0 7/ XLPE4X / XLPE5X / XLPE7X / XLPE2X / XLPE3X10* / XLPE4X / XLPE5X / XLPE7X / XLPE2X / XLPE3X16* / XLPE4X / XLPE5X / XLPE7X / XLPE INSULATED MAINS AND CONTROL CABLE (1.5MM 2 TO 16MM 2 ) -15 to +90 C. 6 x overall diameter. 2 core - Brown, Blue. 3 core - Brown, Black, Grey. 4 core - Brown, Black, Grey, Blue. 5 core and above - up to 6mm 2 - White with Black numbers. 5 core - 10mm 2 and 16mm 2 - Brown, Black, Grey, Blue, Green/Yellow 1.5 & 2.5-2,3,4 core also available in white numbered cores to ESI 09-6 temperatures below 0 C or above +60 C. * Additionally these cables are stocked with Brown, Blue and Green/Yellow core identification.
17 17 MAINS CABLES PVC Stranded plain annealed copper conductors, XLPE insulated, PVC bedding, galvanised steel wire armour, PVC outer sheath. Black. 600/1000 volts grade to BS5467. Flame propagation to BS EN CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND SINGLE CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER SIZE CLEAT (MM) (MM) 6942X / X / X / X / X / X / X / X / X / X / X / X / X / X / X / X / S X / X / X / S X / TC9 6942X / X / S X / X / X / X / X / X / X / S TC9 6942X / X / S TC9 6944X / TC X / X / TC X / S TC X / S TC9 6943X / S TC X / TC12 FIXED WIRING AND MAINS CABLES PVC -15 to +90 C. 8 x overall diameter. 2 core - Brown, Blue. 3 core - Brown, Black, Grey. 4 core - Brown, Black, Grey, Blue. 5 core - Brown, Black, Grey, Blue, Green/Yellow. temperatures below 0 C or above +60 C. XLPE INSULATED MAINS CABLE (25MM 2 TO 400MM 2 )
18 18 FIXED WIRING AND MAINS CABLES MDPE SHEATHED MDPE SHEATHED FIXED WIRING AND MAINS CABLES MDPE SHEATHED Stranded plain annealed copper conductor, XLPE insulated, PVC bedding, galvanised steel wire armour, MDPE outer sheath. Black. 600/1000v volts grade generally to BS5467. CCC CONDUCTOR NO. OF WEIGHT OVERALL GLAND SINGLE CODE SIZE (MM) STRANDING CORES (KG/KM) DIAMETER SIZE (MM) CLEAT 6942PE / S PE / S PE / S PE / S PE / S PE / PE / PE / PE / PE / PE / PE / PE / to + 90 C 8 x Overall Diameter 2 core - Brown, Blue. 3 core - Brown, Black, Grey. also available in Brown, Blue, Green/Yellow. 4 core - Brown, Black, Grey, Blue. 5 core - Brown, Black, Grey, Blue, Green/Yellow. temperatures below 0 C or above 40 C. FIXED WIRING AND MAINS CABLES MDPE (4MM 2 TO 16MM 2 )
19 19 FIXED WIRING AND MAINS CABLES MDPE SHEATHED Stranded plain annealed copper conductor, XLPE insulated, PVC bedding, galvanised steel wire armour, MDPE outer sheath. Black. 600/1000v volts grade generally to BS5467. CCC CONDUCTOR NO. OF WEIGHT OVERALL GLAND SINGLE CODE SIZE (MM) STRANDING CORES (KG/KM) DIAMETER SIZE (MM) CLEAT 6942PE / PE / PE / PE / PE / PE / PE / PE / PE / PE / PE / PE / PE / PE / PE / PE / S PE / PE / PE / S PE / PE / PE / S PE / PE / PE / S PE / TC9 6942PE / S PE / PE / S TC9 6942PE / PE / S TC9 6944PE / TC PE / TC9 6943PE / TC PE / S TC PE / S TC PE / TC14 FIXED WIRING AND MAINS CABLES MDPE SHEATHED - 15 to + 90 C temperatures below 0 C or above 40 C. 8 x Overall Diameter 2 core - Brown, Blue. 3 core - Brown, Black, Grey. also available in Brown, Blue, Green/Yellow. 4 core - Brown, Black, Grey, Blue. 5 core - Brown, Black, Grey, Blue, Green/Yellow. FIXED WIRING AND MAINS CABLES MDPE (25MM 2 TO 400MM 2 )
20 20 FIXED WIRING AND MAINS CABLES PVC MAINS CABLES WITH ALUMINIUM CONDUCTORS PVC Solid plain aluminium sectoral conductors, XLPE insulated, PVC bedding, galvanised steel wire armour, PVC outer sheath. Black. 600/1000 volts grade to BS5467. Flame propagation to BS EN CCC CONDUCTOR NO. OF WEIGHT OVERALL GLAND SINGLE CODE SIZE (MM 2 ) CORES KG/KM DIAMETER SIZE CLEAT (MM) (MM) SAC4X SAC4X SAC4X SAC4X SAC4X SAC4X S 1.8 SAC4X SAC4X TC9 SAC4X S TC9 SAC4X TC10-15 to +90 C. 8 x overall diameter. Brown, Black, Grey, Blue. temperatures below 0 C or above +60 C. XLPE INSULATED MAINS CABLE WITH ALUMINIUM CONDUCTORS (25MM 2 TO 300MM 2 )
21 21 SINGLE CORE NON-ARMOURED MAINS CABLES PVC Plain annealed stranded compacted circular copper conductor, single core, XLPE insulated, PVC outer sheath Black. 600/1000 volts grade to BS7889/97. Flame propagation to BS EN CCC CONDUCTOR STRANDING WEIGHT OVERALL BRASS NYLON SINGLE TREFOIL CODE SIZE (MM 2 ) (MM) KG/KM DIAMETER A2 A2 CLEAT CLEAT (MM) 6181X / X / X / X / X / X / X / X / AC X / S AC X / S AC X / AC X / S AC X / TC9 376AC19 FIXED WIRING AND MAINS CABLES PVC -15 to +90 C. 8 x overall diameter. Brown inner / Black outer. temperatures below 0 C or above +60 C. XLPE INSULATED SINGLE CORE NON-ARMOURED MAINS CABLE (50MM 2 TO 1000MM 2 )
22 22 FIXED WIRING AND MAINS CABLES PVC FIXED WIRING AND MAINS CABLES Stranded plain annealed compacted circular copper conductors, XLPE insulated, PVC bedding, aluminium wire armoured, PVC outer sheath. Black. 600/100 volts grade to BS5467. Flame propagation to BS EN CCC CONDUCTOR NO. OF WEIGHT OVERALL GLAND GLAND SINGLE TREFOIL CODE SIZE (MM) STRANDING CORES (KG/KM) DIAMETER SIZECW SIZE CLEAT CLEAT ALI(MM) BRASS A2 (MM) 6941AX / AX / AX / AX / AX / AX / AC AX / S AC AX / S AC AX / AC AX / S 63S AC AX / S AC AX / S 75S TC9 376AC AX / S 75S TC10 376AC22-15 to + 90 C 6 x Overall Diameter Brown inner - Black outer temperatures below 0 C or above +60 C. XLPE INSULATED SINGLE CORE ARMOURED MAINS CABLE (50MM 2 TO 1000MM 2 )
23 23 MAINS CABLES FOR MINES & QUARRIES PVC Plain annealed stranded copper conductors, XLPE insulated, PVC extruded bedding, galvanised steel wire armour incorporating tinned copper wires to provide 60% conductivity of any one phase, PVC outer sheath. Black. 600/1000 volts grade generally to BS5467 and BC295. Flame propagation to BS EN CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND SINGLE CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER SIZE CLEAT (MM) (MM) NCB3X10/1 10 7/ NCB4X10/1 10 7/ NCB3X16/1 16 7/ NCB4X16/1 16 7/ NCB3X / NCB4X / NCB3X / NCB4X / NCB3X / NCB4X / NCB3X / NCB4X / NCB3X / NCB4X / S 1.6 NCB3X / S 1.6 NCB4X / S 2.0 NCB3X / S 1.8 NCB4X / NCB3X / NCB4X / S TC9 NCB3X / S TC9 NCB4X / TC10 NCB3X / TC10 NCB4X / S TC11 FIXED WIRING AND MAINS CABLES PVC -15 to +70 C. up to 16mm 2-6 x overall diameter. over 16mm 2-8 x overall diameter. 3 core - Brown, Black, Grey. 4 core - Brown, Black, Grey, Blue. temperatures below 0 C or above +60 C. XLPE INSULATED MAINS CABLE WITH 60% CONDUCTIVITY IN ARMOUR. (MINES & QUARRIES & BRITISH COAL) (10MM 2 TO 300MM 2 )
24 24 FIXED WIRING AND MAINS CABLES PVC EEMUA133 CONTROL CABLES PVC Plain annealed stranded copper conductors, XLPE insulated, PVC bedding, lead sheathed, PVC bedding, galvanised steel wire armour, PVC outer sheath. Cores white with black numbers. 600/1000 volts grade to BS5467 and EEMUA 133. Flame propagation to BS EN (IEC ), bunched cables to BS EN (IEC category A) and BS EN (IEC category C). CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND SINGLE CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER SIZE CLEAT (MM) (MM) EEMUA2X1/5ESI 1.5 7/ EEMUA3X1/5ESI 1.5 7/ EEMUA4X1/5ESI 1.5 7/ EEMUA5X1/ / EEMUA7X1/ / EEMUA12X1/ / EEMUA19X1/ / EEMUA27X1/ / EEMUA37X1/ / EEMUA2X2/5ESI 2.5 7/ EEMUA3X2/5ESI 2.5 7/ EEMUA4X2/5ESI 2.5 7/ EEMUA5X2/ / EEMUA7X2/ / EEMUA12X2/ / EEMUA19X2/ / EEMUA27X2/ / EEMUA37X2/ / EEMUA5X / EEMUA7X / to +90 C. 12 x overall diameter. White with Black numbers. temperatures below 0 C or above +60 C. XLPE INSULATED LEAD SHEATHED CONTROL CABLE FOR PETRO-CHEMICAL INDUSTRIES (1.5MM 2 TO 4MM 2 )
25 25 EEMUA133 MAINS CABLES PVC Plain annealed stranded copper conductors, XLPE insulated, PVC bedding, lead sheathed, PVC bedding, galvanised steel wire armour, PVC outer sheath. Black. 600/1000 volts grade to BS5467 and EEMUA 133 (formerly OCMA 4B). Flame propagation to BS EN (IEC ), bunched cables to BS EN (IEC category A) and BS EN (IEC category C). CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND SINGLE CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER SIZE CLEAT (MM) (MM) EEMUA2X1/ / EEMUA3X1/ / EEMUA4X1/ / EEMUA2X2/ / EEMUA3X2/ / EEMUA4X2/ / EEMUA2X / EEMUA3X / EEMUA4X / EEMUA2X / EEMUA3X / EEMUA4X / EEMUA2X / EEMUA3X / EEMUA4X / EEMUA2X / EEMUA3X / EEMUA4X / FIXED WIRING AND MAINS CABLES PVC -15 to +90 C. 12 x overall diameter. 2 core - Brown, Blue. 3 core - Brown, Black, Grey. 4 core - Brown, Black, Grey, Blue. temperatures below 0 C or above +60 C. XLPE INSULATED LEAD SHEATHED MAINS CABLE FOR PETRO-CHEMICAL INDUSTRIES (1.5MM 2 TO 16MM 2 )
26 26 FIXED WIRING AND MAINS CABLES PVC EEMUA133 MAINS CABLES PVC Plain annealed stranded copper conductors, XLPE insulated, PVC bedding, lead sheathed, PVC bedding, galvanised steel wire armour, PVC outer sheath. Black. 600/1000 volts grade to BS5467 and EEMUA 133 (formerly OCMA 4B). Flame propagation to BS EN (IEC ), bunched cables to BS EN (IEC category A) and BS EN (IEC category C). CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND SINGLE CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER SIZE CLEAT (MM) (MM) EEMUA2X / EEMUA3X / EEMUA4X / EEMUA2X / EEMUA3X / EEMUA4X / EEMUA2X / EEMUA3X / EEMUA4X / EEMUA2X / EEMUA3X / EEMUA4X / S 1.8 EEMUA2X / EEMUA3X / S 1.8 EEMUA4X / EEMUA2X / S 1.6 EEMUA3X / EEMUA4X / S TC9 EEMUA2X / S 1.8 EEMUA3X / TC9 EEMUA4X / S TC10 EEMUA2X / EEMUA3X / S TC9 EEMUA4X / TC11 EEMUA2X / TC9 EEMUA3X / TC10 EEMUA4X / S TC11 EEMUA2X / TC11 EEMUA3X / S TC12-15 to +90 C. 12 x overall diameter. 2 core - Brown, Blue 3 core - Brown, Black, Grey. 4 core - Brown, Black, Grey, Blue. temperatures below 0 C or above +60 C. XLPE INSULATED LEAD SHEATHED MAINS CABLE FOR PETRO-CHEMICAL INDUSTRIES (25MM 2 TO 300MM 2 )
27 27 SINGLE CORE NON-ARMOURED CATHODIC PROTECTION CABLES PVC Plain annealed compacted circular copper conductor, XLPE insulated, PVC outer sheath, 600/1000 volts grade generally to BS5467 & IEC Colours Black/Black or Red/Red. CCC CONDUCTOR STRANDING WEIGHT OVERALL GLAND CODE SIZE (MM 2 ) (MM) KG/KM DIAMETER SIZE (MM) (MM) 6181X6 6 7/ / X / / X / S 6181X / S 6181X / X / X / X / X / X / X / FIXED WIRING AND MAINS CABLES PVC 4 x overall diameter. temperatures below 0 C or above +60 C. XLPE INSULATED NON- ARMOURED AND ARMOURED SINGLE CORE CABLE FOR CATHODIC PROTECTION (6MM 2 TO 185MM 2 ) SINGLE CORE ARMOURED CATHODIC PROTECTION CABLES PVC Plain annealed compacted circular copper conductor, XLPE insulated, PVC bedding, galvanised steel wire armour, PVC outer sheath. Black. 600/1000 volts grade generally to IEC & BS5467. CCC CONDUCTOR STRANDING WEIGHT OVERALL GLAND CODE SIZE (MM 2 ) (MM) KG/KM DIAMETER SIZE (MM) (MM) 6941X6 6 7/ / X / / X / S 6941X / S 6941X / X / X / X / X / X / X / x overall diameter. temperatures below 0 C or above +60 C.
28 28 FIXED WIRING AND MAINS CABLES PVC SPLIT CONCENTRIC CABLES PVC Plain annealed stranded copper phase conductor, XLPE insulated surrounded by a concentric layer of plain annealed solid copper neutral conductors. XLPE insulated and plain annealed solid strand bare copper earth conductors, PVC outer sheath. Black. 600/1000 volts grade to BS CCC CONDUCTOR STRANDING WEIGHT OVERALL GLAND CODE SIZE (MM 2 ) (MM) KG/KM DIAMETER SIZE (MM) (MM) 4 SPLITCON 4 7/ S 6 SPLITCON 6 7/ SPLITCON 10 7/ SPLITCON 16 7/ SPLITCON 25 **7/ SPLITCON 35 7/ **Stranding of neutral is the same as phase conductor except 25 sq mm which has 11 x 1.70mm. Conductor identification: Brown Live/Blue Neutral. temperatures below 0 C or above +60 C. Also available in Violet outer sheath in 6mm, 10mm, 16mm & 25mm. STRAIGHT CONCENTRIC CABLES PVC Plain annealed stranded copper phase conductor, PVC insulated surrounded by a concentric layer of plain annealed solid copper neutral/earth conductors in concentric layer, PVC outer sheath. Black. 600/1000 volts grade to BS 7870 & ESI Combined neutral and earth (CNE). CCC CONDUCTOR STRANDING WEIGHT OVERALL GLAND CODE SIZE (MM 2 ) (MM) KG/KM DIAMETER SIZE (MM) (MM) 4 STRCON 4 7/ S 6 STRCON 6 7/ S 16 STRCON 16 7/ STRCON 25 7/ STRCON 35 7/ to +70 C. 10 x overall diameter. temperatures below 0 C or above +60 C. XLPE INSULATED SINGLE PHASE SPLIT AND STRAIGHT CONCENTRIC SERVICE CABLE (4MM 2 TO 35MM 2 )
29 29 FIXED WIRING AND MAINS CABLES 3300V PVC FIXED WIRING AND MAINS CABLES PVC
30 30 FIXED WIRING AND MAINS CABLES PVC SINGLE CORE ARMOURED MAINS CABLES 1900/3300V Stranded plain annealed copper conductors, XLPE insulated, PVC bedding, Aluminium wire armour, PVC outer sheath. Black. 1900/3300 volts grade to BS5467. Flame propagation to BS EN CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND SINGLE TREFOIL CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER SIZE CLEAT CLEAT (MM) (MM) 6941AX120/ / AX150/ / AX185/ / AC AX240/ / AC AX300/ / AC AX400/ / S AC AX500/ / S AC AX630/ / AC15-25 to +90 C. 6 x overall diameter. Brown inner/black outer. temperatures below 0 C or above +60 C. XLPE INSULATED SINGLE CORE ARMOURED MAINS CABLE 3300V (120MM 2 TO 630MM 2 )
31 31 3 CORE MAINS CABLES 1900/3300V PVC Stranded plain annealed copper conductors, XLPE insulated, PVC bedding, galvanised steel wire armour, PVC outer sheath. Black. 1900/3300 volts grade to BS5467. Flame propagation to BS EN CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND SINGLE CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER SIZE CLEAT (MM) (MM) XLPE3X16/3 16 7/ XLPE3X25/3 25 7/ XLPE3X35/3 35 7/ XLPE3X50/ / XLPE3X70/ / XLPE3X95/ / S 1.8 XLPE3X120/ / S 1.8 XLPE3X150/ / XLPE3X185/ / TC9 XLPE3X240/ / S TC9 XLPE3X300/ / TC10 XLPE3X400/ / S TC11-15 to +90 C. 8 x overall diameter. Brown, Black, Grey. temperatures below 0 C or above +60 C. FIXED WIRING AND MAINS CABLES PVC XLPE INSULATED MAINS CABLE 3300 VOLT (16MM 2 TO 400MM 2 )
32 32 FIXED WIRING AND MAINS CABLES PVC MAINS CABLES FOR MINES & QUARRIES 1900/3300V Plain annealed stranded copper conductors, XLPE insulated, PVC extruded bedding, galvanised steel wire armour incorporating tinned copper wires to provide 60% conductivity of any one phase, PVC outer sheath. Black. 1900/3300 volts grade generally to BS5467 and BC295. Flame propagation to BS EN CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND SINGLE CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER SIZE CLEAT (MM) (MM) NCB3X16/3 16 7/ NCB3X25/ / NCB3X35/ / NCB3X50/ / NCB3X70/ / NCB3X95/ / S 1.8 NCB3X120/ / S 1.8 NCB3X150/ / NCB3X185/ / TC9 NCB3X240/ / S TC9 NCB3X300/ / TC10-15 to +70 C. up to 16mm 2-6 x overall diameter. over 16mm 2-8 x overall diameter. 3 core - Brown, Black, Grey temperatures below 0 C or above +60 C. XLPE INSULATED MAINS CABLE 3300V WITH 60% CONDUCTIVITY IN ARMOUR. (MINES & QUARRIES & BRITISH COAL) (16MM 2 TO 300MM 2 )
33 33 EEMUA133 MAINS CABLES 1900/3300V PVC Plain annealed stranded copper conductors, XLPE insulated, PVC bedding, lead sheathed, PVC bedding, galvanised steel wire armour, PVC outer sheath. Black. 1900/3300 volts grade to BS5467 and EEMUA 133 (formerly OCMA 4B). Flame propagation to BS EN (IEC ), bunched cables to BS EN (IEC category A) and BS EN (IEC category C). CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND SINGLE CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER SIZE CLEAT (MM) (MM) EEMUA3X25/3 25 7/ EEMUA3X35/ / EEMUA3X50/ / EEMUA3X70/ / S 1.8 EEMUA3X95/ / S 2.0 EEMUA3X120/ / EEMUA3X150/ / TC9 EEMUA3X185/ / S TC9 EEMUA3X240/ / TC10 EEMUA3X300/ / S TC11 FIXED WIRING AND MAINS CABLES PVC -15 to +90 C. 12 x overall diameter. Brown, Black, Grey. temperatures below 0 C or above +60 C. XLPE INSULATED LEAD SHEATHED MAINS CABLE FOR PETRO-CHEMICAL INDUSTRIES 3300 VOLT (25MM 2 TO 300MM 2 )
34
35 35 FIXED WIRING AND MAINS CABLES LSZH FIXED WIRING AND MAINS CABLES LSZH
36 36 FIXED WIRING AND MAINS CABLES LSZH 6491B (HO7Z-R) LSZH Stranded plain annealed compacted circular copper conductor, low smoke and zero halogen (LSZH) outer sheath. 450/750 volts grade to BS7211. Acid gas emission to BS EN (IEC60754), smoke emission to BS EN (IEC 61034) and flame propagation to BS EN (IEC 60332), low smoke and zero halogen (LSZH). CCC CONDUCTOR STRANDING WEIGHT OVERALL BRASS A2 NYLON A2 CODE SIZE (MM 2 ) (MM) KG/KM DIAMETER (MM) 6491B1/ / / B2/ / / B / / B / / B / / B / / B / S B / S B / B / B / B / B / B / B / B / B / B / S B / S to +90 C. up to 10mm 2-3 x overall diameter above 25mm 2-6 x overall diameter Standard colours available: 1.5mm 2 & 2.5mm 2 - Brown, Black, Grey, Blue, Green/Yellow, White, Orange, Turquoise, Violet, Pink. 4mm 2-630mm 2 - Brown, Black, Grey, Blue, Green/Yellow. temperatures below 0 C or above +40 C. LOW SMOKE ZERO HALOGEN INSULATED WIRING CABLE 6491B (1.5MM 2 TO 630MM 2 )
37 37 XLPE INSULATED LSZH SHEATHED SURFACE WIRING CABLE TYPE 6181B (1MM 2 TO 35MM 2 ) XLPE INSULATED LSZH SHEATHED WIRING CABLE TYPE 624*B (1MM 2 TO 16MM 2 ) SURFACE WIRING CABLES LSZH 6181B Plain annealed stranded circular copper conductor, single core, XLPE insulated, (LSZH) sheathed, Ref 6181B. 300/500 volts grade to BS7889. Brown/White or Grey/White. Acid gas emission to BS EN (IEC60754), smoke emission to BS EN (IEC 61034) and flame propagation to BS EN (IEC 60332), low smoke and zero halogen (LSZH). CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND CLEAT CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER REF SIZE (MM) (MM) 6181B / / B1/ / / B2/ / / B / / B / / B / S B / S B / B / to +90 C. up to 10mm 2-3 x overall diameter over 10mm 2-4 x overall diameter temperatures below 0 C or above +40 C. SURFACE WIRING CABLES LSZH 624*B Plain annealed compacted copper conductor, XLPE insulated, one, two or three cores laid flat with an uninsulated circuit protective conductor and (LSZH) sheathed. White. Ref 6241/2/3B 300/500V to BS7211 low smoke and zero halogen (LSZH). Acid gas emission to BS EN (IEC60754), smoke emission to BS EN (IEC 61034) and flame propagation to BS EN (IEC 60332), low smoke and zero halogen (LSZH). CCC CONDUCTOR STRANDING NO.OF WEIGHT OVERALL CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER (MM) 6241B1/5BR 1.5 1/ X B1/5BR 1.5 1/ X B1WH 1.0 1/ X B1/5WH 1.5 1/ X B1/5BRBR 1.5 1/ X B2/5WH 2.5 1/ X B4WH 4.0 7/ X B6WH 6.0 7/ X B10WH / X B16WH / X B1WH 1.0 1/ X B1/5WH 1.5 1/ X B2/5WH 2.5 1/ X FIXED WIRING AND MAINS CABLES LSZH -25 to +90 C. Fixed = 3 x diameter temperatures below 0 C or above +40 C.
38 38 FIXED WIRING AND MAINS CABLES LSZH MAINS AND CONTROL CABLES LSZH Plain annealed stranded copper conductors, XLPE insulated, low smoke and zero halogen (LSZH) bedding, galvanised steel wire armour, low smoke and zero halogen (LSZH) outer sheath. Black. 600/1000 volts grade to BS6724. Acid gas emission to BS EN (IEC ), smoke emission to BS EN (IEC 61034) and flame propagation to IEC , IEC , BS EN 50265, Categories C & A; BS EN 50266,low smoke and zero halogen (LSZH). CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND SINGLE CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER SIZE CLEAT (MM) (MM) LSF2X1/ / / LSF3X1/ / / LSF4X1/ / S 0.5 LSF5X1/ / S 0.6 LSF7X1/ / S 0.6 LSF12X1/ / LSF19X1/ / LSF27X1/ / LSF37X1/ / LSF48X1/ / LSF2X2/ / S 0.5 LSF3X2/ / S 0.6 LSF4X2/ / S 0.6 LSF5X2/ / LSF7X2/ / LSF12X2/ / LSF19X2/ / LSF27X2/ / LSF37X2/ / LSF48X2/ / LSF2X / S 0.6 LSF3X / S 0.6 LSF4X / LSF5X / LSF7X / LSF12X / LSF19X / LSF27X / LSF2X / LSF3X / LSF4X / LSF5X / LSF7X / LSF2X / LSF3X / LSF4X / LSF5X / LSF7X / LSF2X / LSF3X / LSF4X / LSF5X / LSF7X / XLPE INSULATED LOW SMOKE ZERO HALOGEN MAINS AND CONTROL CABLE (1.5MM 2 TO 16MM 2 ) -25 to +90 C 6 x overall diameter. 2 core - Brown, Blue. 3 core - Brown, Black, Grey. 4 core - Brown, Black, Grey, Blue. 5 core and above - Up to 6mm 2 - White with Black numbers. 5-10mm 2 and 16mm 2 - Brown, Black, Grey, Blue, Green/Yellow. 1.5 & 2.5-2,3,4 core also available in white numbered cores to ESI 09-6 temperatures below 0 C or above +40 C.
39 39 MAINS CABLES LSZH Stranded plain annealed copper conductors, XLPE insulated, low smoke and zero halogen (LSZH) extruded bedding, galvanised steel wire armour, low smoke and zero halogen (LSZH) outer sheath. Black. 600/1000 volts grade to BS6724. Acid gas emission to BS EN (IEC ), smoke emission to BS EN (IEC 61034) and flame propagation to IEC , IEC , BS EN 50265, Categories C & A; BS EN 50266,low smoke and zero halogen (LSZH). CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND SINGLE CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER SIZE CLEAT (MM) (MM) LSF2X / LSF3X / LSF4X / LSF5X / LSF2X / LSF3X / LSF4X / LSF5X / LSF2X / LSF3X / LSF4X / LSF5X / LSF2X / LSF3X / LSF4X / LSF5X / S 1.8 LSF2X / LSF3X / LSF4X / S 1.6 LSF5X / TC9 LSF2X / LSF3X / S 1.6 LSF4X / LSF5X / S TC9 LSF2X / LSF3X / S 1.8 LSF4X / LSF5X / TC11 LSF2X / S 1.8 LSF3X / LSF4X / S TC9 LSF2X / LSF3X / S TC9 LSF4X / TC10 LSF2X / LSF3X / TC10 LSF4X / S TC11 LSF3X / S TC11 LSF4X / TC12 FIXED WIRING AND MAINS CABLES LSZH XLPE INSULATED LOW SMOKE ZERO HALOGEN MAINS CABLE (25MM 2 TO 400MM 2 ) -25 to +90 C. 8 x overall diameter. 2 core - Brown, Blue. 3 core - Brown, Black, Grey. 4 core - Brown, Black, Grey, Blue. 5 core - Brown, Black, Grey, Blue, Green/Yellow. temperatures below 0 C or above +40 C.
40 40 FIXED WIRING AND MAINS CABLES LSZH SINGLE CORE NON-ARMOURED MAINS CABLES LSZH Plain annealed stranded compacted circular copper conductor, single core, XLPE insulated, low smoke and zero halogen (LSZH) outer sheath. Black. 600/1000 volts grade to BS6724. Acid gas emission to BS EN (IEC ), smoke emission to BS EN (IEC 61034) and flame propagation to IEC , IEC , BS EN 50265, Categories C & A; BS EN 50266,low smoke and zero halogen (LSZH). CCC CONDUCTOR STRANDING WEIGHT OVERALL BRASS NYLON SINGLE TREFOIL CODE SIZE (MM 2 ) (MM) KG/KM DIAMETER A2 A2 CLEAT CLEAT (MM) 6181B / B / B / B / B / B / B / B / AC B / S AC B / S AC B / AC B / S AC B / TC9 376AC19-25 to +90 C. 6 x overall diameter. Brown inner/black outer. temperatures below 0 C or above +40 C. XLPE INSULATED LOW SMOKE ZERO HALOGEN SINGLE CORE NON-ARMOURED MAINS CABLE (50MM 2 TO 1000MM 2 )
41 41 SINGLE CORE ARMOURED MAINS CABLES LSZH Stranded plain annealed compacted circular copper conductors, XLPE insulated, low smoke and zero halogen (LSZH) extruded bedding, aluminium wire armour, low smoke and zero halogen (LSZH) outer sheath. Black. 600/1000 volts grade to BS6724. Acid gas emission to BS EN (IEC ), smoke emission to BS EN (IEC 61034) and flame propagation to IEC , IEC , BS EN 50265, Categories C & A; BS EN 50266,low smoke and zero halogen (LSZH). CCC CONDUCTOR NO. OF WEIGHT OVERALLGLAND GLAND SINGLE TREFOIL CODE SIZE(MM) STRANDING CORES (KG/KM) DIAMETER SIZECW SIZE CLEAT CLEAT ALI BRASS A2 (MM) (MM) 6941AB / AB / AB / AB / AB / AB / AC AB / S AC AB / S AC AB / AC AB / S 63S AC AB / S AC AB / S 75S TC9 376AC AB / S 75S TC10 376AC22 FIXED WIRING AND MAINS CABLES LSZH - 25 to + 90 C 6 x Overall Diameter Brown inner - Black outer temperatures below 0 C or above +40 C. XLPE INSULATED LOW SMOKE ZERO HALOGEN SINGLE CORE ARMOURED MAINS CABLE (50MM 2 TO 1000MM 2 )
42 42 FIXED WIRING AND MAINS CABLES LSZH SCREENED FIXED WIRING AND MAINS CABLES TO BS 8436 Plain annealed stranded copper, XLPE insulated, tinned annealed stranded copper earth wire, bonded aluminium tube applied longitudinally, low smoke and zero halogen (LSZH) outer sheath, to BS EN :1998 and BS EN :2000, UV Stable. 600/1000v to BS8436, White. Acid gas emissions to BS EN , smoke emissions to BS EN and flame retardant to BS EN (IEC ). CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL 1 HOLE GLAND CODE SIZE (MM2) (MM) CORES KG/KM DIAMETER CLIP REF (MM) REF FSX2X1WH 1.0 7/ RCHL34 20SA2 FSX3X1WH 1.0 7/ RCHL37 20SA2 FSX4X1WH 1.0 7/ RCHL37 20A2 FSX2X1/5WH 1.5 7/ RCHL37 20A2 FSX3X1/5WH 1.5 7/ RCHL40 20A2 FSX4X1/5WH 1.5 7/ RCHL43 20A2 FSX2X2/5WH 2.5 7/ RCHL43 20A2 FSX3X2/5WH 2.5 7/ RCHL43 20A2 FSX4X2/5WH 2.5 7/ RCHL47 20A2 FSX2X4WH 4 7/ RCHL43 20A2 FSX3X4WH 4 7/ RCHL51 25A2 FSX4X4WH 4 7/ RCHL54 25A2 FSX2X6WH 6 7/ RCHL51 25A2 FSX3X6WH 6 7/ RCHL54 25A2 FSX4X6WH 6 7/ RCHL59 25A2 FSX2X10WH 10 7/ RCHL63 25A2 Minimum installation temperature: -10 C. Maximum continuous conductors operating temperature: +90 C. 2 core - Brown, Blue. 3 core - Brown, Black, Grey. 4 core - Brown, Black, Grey, Blue. Solid cores available on request. Different sheath and core colours available on request. 10mm 2 and 16mm 2 available on request Also available in 300/500 volt rating. MECHANICALLY PROTECTED WIRING CABLE
43 43 FIXED WIRING AND MAINS CABLES 11000V, 22000V, AND 33000V FIXED WIRING AND MAINS CABLES
44 44 FIXED WIRING AND MAINS CABLES SINGLE CORE ARMOURED MAINS CABLES PVC 11000V Stranded plain annealed circular compacted copper conductors, XLPE insulated, semi-conducting tape insulated, copper tape screen, PVC bedding, aluminium wire armour, PVC outer sheath - Red. 6350/11000 volts grade to BS6622 and IEC Flame propagation to BS EN Red outer sheath can be prone to fading when exposed to U.V rays. CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND SINGLE TREFOIL RAYCHEM CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER SIZE CLEAT CLEAT TERMINATION (MM) (MM) REFERENCE / AC04 EPKT 17B1XI / AC05 EPKT 17B1XI / AC06 EPKT 17C1XI / AC07 EPKT 17C1XI / AC08 EPKT 17C1XI / AC09 EPKT 17C1XI / S AC11 EPKT 17C1XI / S AC12 EPKT 17D1XI / S AC14 EPKT 17D1XI / AC17 EPKT 17E1XI / S TC9 376AC19 EPKT 17E1XI SINGLE CORE (50MM 2 TO 630MM 2 ) AND 3 CORE (25MM 2 TO 400MM 2 ) XLPE INSULATED MEDIUM VOLTAGE MAINS CABLES VOLT up to 90 C. 12 x overall diameter. Brown. temperatures below 0 C or above +60 C. 3 CORE MAINS CABLES PVC 11000V Stranded plain annealed circular compacted copper conductors, XLPE insulated, semi-conducting tape insulated, each core copper tape screened, PVC bedding, galvanised steel wire armour, PVC outer sheath - Red. 6350/11000 volts grade to BS6622 and IEC Flame propagation to BS EN Red outer sheath can be prone to fading when exposed to U.V rays. CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND SINGLE RAYCHEM CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER SIZE CLEAT TERMINATION (MM) (MM) REFERENCE 11KV XLPE3X25RD 25 7/2/ EPKT 17A3XIH2 11KV XLPE3X35RD 35 19/1/ EPKT 17B3XIH2 11KV XLPE3X50RD 50 19/1/ S TC9 EPKT 17B3XIH2 11KV XLPE3X70RD 70 19/2/ S TC9 EPKT 17B3XIH2 11KV XLPE3X95RD 95 19/2/ TC10 EPKT 17C3XIH2 11KV XLPE3X120RD /2/ S TC11 EPKT 17C3XIH2 11KV XLPE3X150RD /2/ S TC11 EPKT 17C3XIH2 11KV XLPE3X185RD /2/ TC12 EPKT 17C3XIH2 11KV XLPE3X240RD /2/ TC14 EPKT 17C3XIH2 11KV XLPE3X300RD /2/ TC14 EPKT 1D3XIH2 11KV XLPE3X400RD /2/ TC15 EPKT 17D3XIH2 up to 90 C. 12 x overall diameter. Brown, Black, Grey tapes. temperatures below 0 C or above +60 C.
45 45 3 CORE MAINS CABLES PVC 11000V Plain stranded aluminium conductors, XLPE insulated, semi-conducting tape insulated, each core copper tape screened, PVC bedding (extruded), galvanised steel wire armour, PVC outer sheath. Red. 6350/11000 volts grade to BS6622 and IEC Flame propagation to BS EN Red outer sheath can be prone to fading when exposed to U.V rays. CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND SINGLE RAYCHEM CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER SIZE CLEAT TERMINATION (MM) (MM) REFERENCE 10115RD 95 19/ TC10 EPKT 17C3XIH RD / S TC11 EPKT 17C3XIH RD / S TC11 EPKT 17C3XIH RD / TC12 EPKT 17C3XIH RD / TC14 EPKT 17C3XIH RD / TC15 EPKT 17D3XIH2 up to 90 C. 13 x overall diameter. Brown, Black, Grey tapes. temperatures below 0 C or above +60 C. FIXED WIRING AND MAINS CABLES XLPE INSULATED MEDIUM VOLTAGE MAINS CABLE VOLT (95MM 2 TO 300MM 2 )
46 46 FIXED WIRING AND MAINS CABLES TRIPLEX CABLES 11000V Solid or stranded aluminium conductor, XLPE insulated, copper wire screen (35mm2). MDPE outer sheath. Red. 6350/11000 volts grade to BS7870. Red outer sheath can be prone to fading when exposed to U.V rays. CCC CONDUCTOR CONDUCTOR NOMINAL NO. OF WEIGHT DIAMETER CODE SIZE (MM 2 ) TYPE CONDUCTOR CORES KG/KM IN TRIPLEX DIAMETER FORMATION 11KVTRIP3X70AL 70 SOLID KVTRIP3X70AL 70 STRANDED KVTRIP3X95AL 95 SOLID KVTRIP3X95AL 95 STRANDED KVTRIP3X185AL 185 SOLID KVTRIP3X185AL 185 STRANDED KVTRIP3X300AL SOLID KVTRIP3X300AL STRANDED to +90 C. 15 x overall diameter. Brown, Black, Grey tapes. temperatures below 0 C. 3 CORE UTILITY CABLE TRIPLEX FORMATION XLPE INSULATED MEDIUM VOLTAGE CABLE VOLT (70MM 2 TO 300MM 2 )
47 47 PAPER INSULATED MAINS CABLES PVC 11000V COPPER CONDUCTOR Plain annealed copper conductors, paper insulated, paper belted, semiconducting carbon paper tape bedding, lead sheathed, textile compound bedding, galvanised steel wire armour, PVC outer sheath - Red. 6350/11000 volts grade to BS6480/88. Flame propagation to BS EN Red outer sheath can be prone to fading when exposed to U.V rays. CCC CONDUCTOR STRANDING No. OF WEIGHT OVERALL SINGLE RAYCHEM CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER CLEAT TERMINATION (MM) REFERENCE PILC3X25RD 25 7/ EPKT 17A3MIH2 PILC3X35RD 35 19/ EPKT 17B3MIH2 PILC3X50RD 50 19/ EPKT 17B3MIH2 PILC3X70RD 70 19/ EPKT 17B3MIH2 PILC3X95RD 95 19/ TC9 EPKT 17C3MIH2 PILC3X120RD / TC9 EPKT 17C3MIH2 PILC3X150RD / TC10 EPKT 17C3MIH2 PILC3X185RD / TC10 EPKT 17C3MIH2 PILC3X240RD / TC11 EPKT 17C3MIH2 PILC3X300RD / TC12 EPKT 17D3MIH2 PILC3X400RD / TC14 EPKT 17D3MIH2 FIXED WIRING AND MAINS CABLES PAPER INSULATED MEDIUM VOLTAGE MAINS CABLE VOLT (25MM 2 TO 400MM 2 ) up to 65 C. 13 x overall diameter. White printed numbers on insulating papers. temperatures below 0 C or above +60 C. ALUMINIUM CONDUCTOR Plain aluminium stranded conductors, paper insulated, paper belted, semiconducting carbon paper tape bedding, lead sheathed, textile compound bedding, galvanised steel wire armour, PVC outer sheath - Red. 6350/11000 volts grade to BS6480/88. Flame propagation to BS EN Red outer sheath can be prone to fading when exposed to U.V rays. CCC CONDUCTOR STRANDING No. OF WEIGHT OVERALL SINGLE RAYCHEM CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER CLEAT TERMINATION (MM) REFERENCE 10100RD 95 19/ TC9 EPKT 17C3MIH RD / TC11 EPKT 17C3MIH RD / TC12 EPKT 17D3MIH2 up to 65 C. 13 x overall diameter. White printed numbers on insulating papers. temperatures below 0 C or above +60 C.
48 48 FIXED WIRING AND MAINS CABLES SINGLE CORE (50MM 2 TO 630MM 2 ) AND 3 CORE (25MM 2 TO 400MM 2 ) XLPE INSULATED LOW SMOKE ZERO HALOGEN MEDIUM VOLTAGE MAINS CABLES VOLT SINGLE CORE ARMOURED MAINS CABLES LSZH 11000V Stranded plain annealed compacted circular copper conductor, XLPE insulated, semi-conducting tape insulated, copper tape screen, low smoke and zero halogen (LSZH) bedding, aluminium wire armour, low smoke and zero halogen (LSZH) outer sheath - Red. 6350/11000 volts grade to BS7835. Acid gas emission to BS EN (IEC60754), smoke emission to BS EN (IEC 61034) and flame propagation to BS EN 50265, BS EN (IEC 60332). Due to poor U.V resistant qualities, red outer sheath cables are not recomended for outdoor installation. CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND SINGLE TREFOIL RAYCHEM CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER SIZE CLEAT CLEAT TERMINATION (MM) (MM) REFERENCE / AC04 EPKT 17B1XI / AC05 EPKT 17B1XI / AC06 EPKT 17C1XI / AC07 EPKT 17C1XI / AC08 EPKT 17C1XI / AC09 EPKT 17C1XI / S AC11 EPKT 17C1XI / S AC12 EPKT 17D1XI / S AC14 EPKT 17D1XI X AC17 EPKT 17E1XI X S TC9 376AC19 EPKT 17E1XI up to 90 C. 15 x overall diameter. Brown. temperatures below 0 C or above +40 C. 3 CORE MAINS CABLES LSZH 11000V Stranded plain annealed compacted circular copper conductors, XLPE insulated, semi-conducting tape insulated, each core copper tape screened, low smoke and zero halogen (LSZH) bedding, galvanised steel wire armour, low smoke and zero halogen (LSZH) outer sheath - Red. 6350/11000 volts grade to BS7835. Acid gas emission to BS EN (IEC60754), smoke emission to BS EN (IEC 61034) and flame propagation to BS EN 50265, BS EN (IEC 60332). Due to poor U.V resistant qualities red outer sheath cables are not recomended for outdoor installation. CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND SINGLE RAYCHEM CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER SIZE CLEAT TERMINATION (MM) (MM) REFERENCE 10302RD 35 19/ TC9 EPKT 17B3XIH RD 50 19/ S TC9 EPKT 17B3XIH RD 70 19/ S TC9 EPKT 17B3XIH RD 95 19/ TC10 EPKT 17C3XIH RD / S TC11 EPKT 17C3XIH RD / TC11 EPKT 17C3XIH RD / TC12 EPKT 17C3XIH RD / TC14 EPKT 17C3XIH RD / TC14 EPKT 17D3XIH RD / TC15 - up to 90 C. 12 x overall diameter. temperatures below 0 C or above +40 C. Brown, Black, Grey tapes.
49 49 THREE CORE MAINS CABLES 22KV AND 33KV Compacted circular stranded annealed copper conductor, extruded semiconductive conductor screen, XLPE insulated, extruded strippable semiconductive insulation screen helically overlapped copper tape metallic screen, extruded low smoke zero halogen(lszh) bedding, galvanised steel wire armour, extruded low smoke zero halogen (LSZH) sheath - Red /22000 volts grade to BS7835. Due to poor U.V resistant qualities red outer sheath cables are not recommended for outdoor installation. CCC CODE CONDUCTOR STRANDING NO. OF WEIGHT OVERALL SIZE (MM) CORES (KG/KM) DIAMETER 22KVXLPE3X95RD / to + 90 C temperatures below 0 C or * above +40 C. Bending radius: 12 x overall diameter Brown, Black, Grey tapes. FIXED WIRING AND MAINS CABLES Compacted circular stranded annealed copper conductor, extruded semiconductive conductor screen, XLPE insulated, extruded strippable semiconductive insulation screen helically overlapped copper tape metallic screen, extruded low smoke zero halogen(lszh) bedding, galvanised steel wire armour, extruded low smoke zero halogen (LSZH) sheath - Red /33000 volts grade to BS7835. Due to poor U.V resistant qualities red outer sheath cables are not recommended for outdoor installation. CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL CODE SIZE (MM) CORES (KG/KM) DIAMETER 33KVLSF3X95RD / KVLSF3X185RD / to + 90 C 12 x overall diameter Brown, Black, Grey tapes. temperatures below 0 C or above +40 C. 3 CORE XLPE INSULATED LOW SMOKE ZERO HALOGEN MEDIUM VOLTAGE MAINS CABLE VOLT (95MM 2 ) AND VOLT (95MM 2 / 185MM 2 )
50
51 51 FIXED WIRING AND MAINS CABLES 33000V - SERVICE AND WINDFARM FIXED WIRING AND MAINS CABLES
52 52 FIXED WIRING AND MAINS CABLES SINGLE CORE MAINS CABLE MDPE 33000V WINDFARM CABLE Round stranded compacted aluminium conductor, inner semi-conductive layer XLPE insulated, outer semi-conductive layer, semi-conductive swelling tape insulation screen, copper wire and tape metallic screen (35mm2), polyester tape/water blocking swelling tape seperator, extruded black MDPE outer sheath volts grade to BS7870, IEC CCC CODE CONDUCTOR STRANDING NO. OF WEIGHT OVERALL SIZE (MM) CORES (KG/KM) DIAMETER 33KV1X70AL / KV1X95AL / KV1X120AL / KV1X150AL / KV1X185AL / KV1X240AL / KV1X300AL / KV1X400AL / KV1X500AL / KV1X630AL / Rated voltage Uo/U 19/33 Kv Max operating voltage 36 kv Test voltage 75 kv Partial discharge level with voltage 2Uo Kv max. 5pC Max. perm conductor temperature 90 C Max. perm operating temperature 130 C Short circuit temperature 250 C *Minimum bending radius 12 x overall diameter SINGLE CORE VOLT RATED WINDFARM CABLE ALUMINIUM CONDUCTOR (70MM TO 630MM)
53 53 SINGLE CORE MAINS CABLE MDPE 33000V SERVICE CABLE Round stranded compacted copper conductor, inner semi-conductive layer XLPE insulated, outer semi-conductive layer, semi-conductive swelling tape insulation screen, copper wire and tape metallic screen (35mm2), polyester tape/water blocking swelling tape seperator, extruded black MDPE outer sheath volts grade to BS7870, IEC CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL CODE SIZE (MM) CORES (KG/KM) DIAMETER 33KVCU1X70BK / KVCU1X95BK / KVCU1X120BK / KVCU1X150BK / KVCU1X185BK / KVCU1X240BK / KVCU1X300BK / KVCU1X400BK / KVCU1X500BK / KVCU1X630BK / FIXED WIRING AND MAINS CABLES Rated voltage Uo/U 19/33 Kv Max operating voltage 36 kv Test voltage 75 kv Partial discharge level with voltage 2Uo Kv max. 5pC Max. perm conductor temperature 90 C Max. perm operating temperature 130 C Short circuit temperature 250 C *Minimum bending radius 12 x overall diameter SINGLE CORE VOLT RATED SERVICE CABLE COPPER CONDUCTOR (70MM TO 630MM)
54
55 55 FIREPROOF CABLES FIREPROOF CABLES
56 56 FIREPROOF CABLES FIREPROOF CABLES - MINERAL INSULATED Solid plain annealed copper conductors, magnesium oxide insulated, solid copper sheath to BS6207, IEC 331 and BS 6387 CWZ. Available in the following options: (a) Light Duty = 500 volts grade Heavy Duty = 1000 volts grade (b) Outer sheath finishes, bare copper, PVC or LSZH (c) Outer sheath colours. Orange, Red, White or Black. SIZE BARE SHEATHED OVERALL OVERALL GLAND SINGLE HOLE CLIP NOMINAL REF. KG/KM KG/KM DIAMETER DIAMETER FOR USE REFERENCE STD DRUM BARE SHEATHED WITH RPS BARE SHEATHED LTHS (MTS) (MM) (MM) SEALS 2L L L L L L L L L L L L H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H PVC sheath -20 to +70 C. LSF sheath -20 to +80 C. 6 x overall diameter. temperatures below 0 C. MINERAL INSULATED CABLE (1.0MM 2 TO 240MM 2 )
57 57 STANDARD FIRE ALARM AND SECURITY WIRING CABLES Plain annealed copper conductor, silicon rubber insulated aluminium/polyester tape screen, tinned annealed copper earth wire, low smoke zero halogen (LSZH) outer sheath. Red, White, Orange or Black. Fire resistant to IEC 331 and BS6387. Flame retardant to BS5839-1:2003 and IEC CAT CWZ, BS Acid gas emission to BS EN (IEC60754), smoke emission to BS EN (IEC 61034) and flame propagation to BS EN 50265, BS EN (IEC 60332). FIREPROOF CABLES CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND 1 HOLE GLAND CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER SIZE CLIP REF REF (MM) (MM) FP2X / E FP3X / E FP4X / E FP7X / E FP12X / E FP2X1/ / E FP3X1/ / E FP4X1/ / E FP7X1/ / D FP12X1/ / D FP19X1/ / D FP2X2/ / E FP3X2/ / E FP4X2/ / E FP7X2/ / D FP12X2/ / D FP19X2/ / D FP2X / E FP3X / E FP4X / E E = Bare earth conductor. D = Drain wire -10 to +80 C. 6 x overall diameter. 2 core - Brown, Blue. 3 core - Brown, Black, Grey. 4 core - Brown, Black, Grey, Blue. 7 core and above - White with Black numbers. temperatures below 0 C or above +40 C. FIRE RESISTANT FIRE ALARM & SECURITY CABLE STANDARD (1.0MM 2 TO 4MM 2 )
58 58 FIREPROOF CABLES ENHANCED FIRE ALARM AND SECURITY WIRING CABLES Plain annealed copper conductor, enhanced silicon rubber insulated, enhanced aluminium/polyester tape screen, tinned annealed copper earth wire, enhanced low smoke zero halogen outer sheath. Red or white. Manufactured to meet the Enhanced standard of BS A2:2008 Clause 26.2e Enhanced and also the requirements of BS8434-2: minutes and BS EN Class PH120. Fire resistant to BS7629-1:2008, BS6387:1994 clause 11 CWZ, halogen emissions to bs en :1999 and low smoke standard BS EN :2005. CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND 1 HOLE GLAND CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER SIZE CLIP REF REF (MM) (MM) ENH2X1/ / E ENH3X1/ / E ENH4X1/ / E ENH2X2/ / E ENH3X2/ / E ENH4X2/ / E ENH2x / E ENH3x / E ENH4x / E E = Bare earth conductor. -40 to +90 C. 6 x overall diameter. 2 core - Brown, Blue. 3 core - Brown, Black, Grey. 4 core - Brown, Black, Grey, Blue. temperatures below 0 C or above +40 C. FIRE RESISTANT FIRE ALARM & SECURITY CABLE ENHANCED (1.5MM 2 TO 4MM 2 )
59 59 FIREPROOF CABLES - SINGLES Plain annealed copper conductor, mica fire resistant tape, low smoke zero halogen (LSZH) insulation. 600/1000 volts grade. Fire resistant to IEC 331 and BS6387, CWZ when tested in steel conduit. Manufactured to meet the following standards - acid gas emission to BS EN 50267, flame retardant to BS EN and smoke emission to BS7211. CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL CODE SIZE (MM) CORES (KG/KM) DIAMETER 6491F1/ / F2/ / F / F / F / F / FIREPROOF CABLES - 40 to + 90 C 8 x Overall Diameter Standard colours available: Brown, Blue, Grey, Black, Green/Yellow. temperatures below 0 C or above 40 C. FIRE RESISTANT SINGLE CORE CABLES (1.5MM 2 TO 16MM 2 )
60 60 FIREPROOF CABLES FIREPROOF MAINS AND CONTROL CABLES LSZH Plain annealed stranded copper conductor, mica fire resistant tape, XLPE insulated, low smoke & zero halogen (LSZH) bedding, galvanised steel wire armour, low smoke & zero halogen (LSZH) outer sheath. Black. 600/1000 volts. Fire resistant to IEC 331 & BS7846 F2 / BS6387 & CWZ. Acid gas emission to BS EN (IEC60754), smoke emission to BS EN (IEC 61034) and flame propagation to BS EN 50265, BS EN (IEC ). CCC CONDUCTOR STRANDING NO. OF WEIGHT OUTSIDE GLAND SINGLE CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER SIZE CLEAT (MM) (MM) 6942F1/ / / F1/ / / F1/ / S F1/ / S /12F1/ / /19F1/ / /27F1/ / /37F1/ / F2/ / S F2/ / S F2/ / S F2/ / /12F2/ / /19F2/ / /27F2/ / /37F2/ / F4 4 7/ S F4 4 7/ S F4 4 7/ F4 4 7/ F4 4 7/ F6 6 7/ F6 6 7/ F6 6 7/ F6 6 7/ F / F / F / F / F / F / F / F / FIRE RESISTANT POWER AND CONTROL CABLE (1.5MM 2 TO 16MM 2 ) -40 to +90 C. 8 x overall diameter. 2 core - Brown, Blue. 3 core - Brown, Black, Grey. 4 core - Brown, Black, Grey, Blue. 5 core and above 4mm 2 and 6mm 2 - White with Black numbers. 5 core - 10mm 2 and 16mm 2 - Brown, Black, Grey, Blue, Green/Yellow. temperatures below 0 C or above 40 C.
61 61 FIREPROOF MAINS CABLES LSZH Plain annealed stranded copper conductor, mica fire resistant tape, XLPE insulated, low smoke, zero halogen (LSZH) bedding, galvanised steel wire armour, low smoke, zero halogen (LSZH) outer sheath. Black. 600/1000 volts grade. Fire resistant to BS6387/BS7846 F2 & CWZ. Acid gas emission to BS EN (IEC60754), smoke emission to BS EN (IEC 61034) and flame propagation to BS EN 50265, BS EN (IEC ). FIREPROOF CABLES CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND SINGLE CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER SIZE CLEAT (MM) (MM) FP2X / FP3X / FP4X / FP5X / FP2X / FP3X / FP4X / FP2X / FP3X / FP4X / FP2X / FP3X / FP4X / FP2X / FP3X / FP4X / S 1.8 FP2X / FP3X / S 1.8 FP4X / FP2X / S 1.8 FP3X / FP4X / TC9 FP2X / FP3X / TC9 FP4X / S TC10 FP2X / TC9 FP3X / S TC9 FP4X / TC11 FP2X / S TC9 FP3X / TC10 FP4X / S TC12 FP3X / S TC11 FP4X / TC14-40 to +90 C. 8 x overall diameter. 2 core - Brown, Blue. 3 core - Brown, Black, Grey. 4 core - Brown, Black, Grey, Blue. 5 core - Brown, Black, Grey, Blue, Green/Yellow. temperatures below 0 C or above 40 C. FIRE RESISTANT POWER CABLE (25MM 2 TO 400MM 2 )
62 62 FIREPROOF CABLES FIREPROOF MAINS AND CONTROL CABLES LSZH - ENHANCED Plain annealed stranded copper conductor, mica fire resistant tape, XLPE insulated, polyester tape, low smoke zero halogen (LSZH) bedding, fire barrier tape, galvanised steel wire armour, low smoke zero halogen (LSZH) outer sheath.black. 600/1000 grade volts. Manufactured to meet the following standards - circuit integrity: BS minutes/bs8491, acid gas emission to IEC 60754, BS EN 50267, flame propagation to IEC , BS EN 50265, BS EN50266 and smoke emission to IEC 61034, BS EN CCC CONDUCTOR NO. OF WEIGHT OVERALL GLAND SINGLE CODE SIZE (MM) STRANDING CORES (KG/KM) DIAMETER SIZE (MM) CLEAT FPE2X / FPE3X / FPE4X / FPE2X / FPE3X / FPE4X / FPE2X / FPE3X / FPE4X / FPE2X / FPE3X / FPE4X / to + 90 C 8 x Overall Diameter 2 core - Brown. Blue. 3 core - Brown, Black, Grey. 4 core - Brown, Black, Grey, Blue. temperatures below 0 C or above 40 C. FIRE RESISTANT POWER AND CONTROL CABLE - ENHANCED (4MM 2 TO 16MM 2 )
63 63 FIREPROOF MAINS CABLES LSZH - ENHANCED Plain annealed stranded copper conductor, mica fire resistant tape, XLPE insulated, polyester tape, low smoke zero halogen (LSZH) bedding, fire barrier tape, galvanised steel wire armour, low smoke zero halogen (LSZH) outer sheath.black. 600/1000 grade volts. Manufactured to meet the following standards - circuit integrity: BS minutes/bs8491, acid gas emission to IEC 60754, BS EN 50267, flame propagation to IEC , BS EN 50265, BS EN50266 and smoke emission to IEC 61034, BS EN FIREPROOF CABLES CCC CONDUCTOR NO. OF WEIGHT OVERALL GLAND SINGLE CODE SIZE (MM) STRANDING CORES (KG/KM) DIAMETER SIZE (MM) CLEAT FPE2X / FPE3X / FPE4X / FPE2X / FPE3X / FPE4X / FPE2X / FPE3X / FPE4X / FPE2X / FPE3X / FPE4X / FPE2X / FPE3X / S 1.8 FPE4X / FPE2X / S 1.6 FPE3X / S 1.8 FPE4X / TC9 FPE2X / S 1.8 FPE3X / FPE4X / S TC9 FPE2X / FPE3X / S TC9 FPE4X / TC10 FPE2X / TC9 FPE3X / TC10 FPE4X / S TC11 FPE2X / S TC9 FPE3X / TC10 FPE4X / TC12 FPE3X / S TC12 FPE4X / TC14-40 to + 90 C 8 x Overall Diameter 2 core - Brown. Blue. 3 core - Brown, Black, Grey. 4 core - Brown, Black, Grey, Blue. temperatures below 0 C or above 40 C. FIRE RESISTANT POWER AND CONTROL CABLE - ENHANCED (25MM 2 TO 400MM 2 )
64
65 65 FLEXIBLE CABLES FLEXIBLE CABLES
66 66 FLEXIBLE CABLES PVC INSULATED FLEXIBLE CORDS 218*Y - 318*Y Plain annealed flexible copper conductors, PVC insulated, PVC outer sheath. Black or White. 300/500 volts grade to BS6500. (Harmonized code HO5VV-F). Flame propagation to BS EN CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER SIZE (MM) (MM) **2182Y/ / /16 **2182Y/ / /16 **2183Y/ / /16 **2183Y/ / / Y/ / / Y/ / / Y/ / / Y/ / / Y/ / / Y/ / S 3182Y / / Y / / Y / S 3185Y / S 3182Y1/ / / Y1/ / S 3184Y1/ / S 3185Y1/ / Y2/ / S 3183Y2/ / S 3184Y2/ / Y2/ / Fixed - -5 to +60 C. Flexing - +5 to +60 C. Fixed 2 x overall diameter. Flexing 6 x overall diameter. 2 core - Blue, Brown. 3 core - Blue, Brown, Green/Yellow. 4 core - Blue, Brown, Black, Green/Yellow (ccc standard stock) as per Cenelec HD 308 four core is available in an alternative core identification - brown, black, grey, green/yellow. 5 core - Blue, Brown, Black, Grey, Green/Yellow. temperatures below 0 C. **Light flexible cords 300/300 volts grade PVC INSULATED FLEXIBLE CORDS TYPE 218*Y & 318*Y (0.5MM 2 TO 2.5MM 2 )
67 67 PVC INSULATED FLEXIBLE CORDS 309*Y Plain annealed flexible copper conductors heat resisting PVC outer sheath. White 300/500 volts grade to BS6141. Flame propagation to BS EN CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER SIZE (MM) (MM) 3092Y/ / / Y/ / / Y/ / / Y/ / S 3093Y/ / S 3094Y/ / S 3095Y/ / S 3092Y / S 3093Y / S 3094Y / S 3092Y1/ / S 3093Y1/ / S 3094Y1/ / Y2/ / S 3093Y2/ / Y2/ / FLEXIBLE CABLES PVC INSULATED FLEXIBLE CORDS TYPE 309*Y (0.5MM 2 TO 2.5MM 2 ) AND ARTIC GRADE (1.5MM 2 TO 4MM 2 ) Fixed - -5 to +90 C. Flexing - +5 to +90 C. Fixed - 2 x overall diameter. Flexing - 6 x overall diameter. 2 core - Blue, Brown. 3 core - Blue, Brown, Green/Yellow. 4 core - Blue, Brown, Black, Green/Yellow. temperatures below 0 C. ARCTIC GRADE FLEXIBLE CORDS Plain annealed flexible copper conductors, low temperature PVC insulation, low temperature PVC outer sheath. Blue or Yellow. 300/500 volts grade to BS7919 table 44 and BS6500. Flame propagation to BS EN CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER SIZE (MM) (MM) 3183AG1/ / S 3184AG1/ / S 3183AG2/ / S 3184AG2/ / AG4 4 56/ AG6 6 76/ Flexing - 40 to + 70 C 6 x overall diameter. 3 core - Blue, Brown, Green/Yellow. 4 core - Blue, Brown, Black, Green/Yellow.
68 68 FLEXIBLE CABLES ZERO HALOGEN FLEXIBLE CORDS (HO5 ZIZI-F) Plain annealed copper conductors, Low smoke and zero halogen (LSZH) insulated, low smoke and zero halogen (LSZH) outer sheath. Black or white. 300/500 volts grade (Generally to BS6500) Harmonised code HO5 ZIZI-F. Acid gas emission to BS EN (IEC ), smoke emission to BS EN (IEC 61034) and flame propagation to BS EN (IEC ). CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER SIZE (MM) (MM) 3182B/ / / B/ / / B/ / / B/ / S 3182B / / B / / B / S 3185B / S 3182B1/ / / B1/ / S 3184B1/ / S 3185B1/ / B2/ / S 3183B2/ / S 3184B2/ / B2/ / to +70 c Fixed 4x overall diameter Flexing 6x overall diameter 2 core - Brown, Blue. 3 core - Blue, Brown, Green/Yellow. 4 core - Blue, Brown, Black, Green/Yellow (ccc standard stock) as per Cenelec HD 308 four core is available in an alternative core identification - brown, black, grey, green/yellow. 5 core - Blue, Brown, Black, Grey, Green/Yellow. temperatures below 0 C. LOW SMOKE ZERO HALOGEN FLEXIBLE CORDS TYPE 318*B (0.75MM 2 TO 2.5MM 2 )
69 69 TYPE YY CONTROL CABLES Plain annealed flexible copper conductors, PVC insulated, PVC sheathed. Grey. 300/500 volts grade, generally to BS6500 and VDE CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER SIZE (MM) (MM) YY2X/ / /16 YY3X/ / /16 YY4X/ / /16 YY5X/ / /16 YY7X/ / /16 YY12X/ / S YY18X/ / YY25X/ / YY34X/ / YY50X/ / YY65X/ / YY2X / /16 YY3X / /16 YY4X / /16 YY5X / /16 YY7X / S YY12X / S YY18X / YY25X / YY34X / YY41X / YY50X / YY65X / YY2X1/ / /16 YY3X1/ / /16 YY4X1/ / /16 YY5X1/ / S YY7X1/ / S YY8X1/ / YY10X1/ / YY12X1/ / YY18X1/ / YY25X1/ / YY34X1/ / YY50X1/ / YY65X1/ / FLEXIBLE CABLES -5 to +70 C. Static - 6 x overall diameter. Flexing - 15 x overall diameter. 2 core - Black with White numbers. 3 core and above - Black with White numbers plus Green/Yellow. temperatures below -5 C. Also available with coloured cores as follows: 2 core - Blue, Brown. 3 core - Blue, Brown, Green/Yellow. 4 core - Blue, Brown, Black, Green/Yellow (ccc standard stock) as per Cenelec HD 308 four core is available in an alternative core identification - brown, black, grey, green/yellow. 5 core - Blue, Brown, Black, Grey, Green/Yellow. 7 core - Blue, Brown, Black, Grey, White, Red, Green/Yellow. PVC INSULATED FLEXIBLE POWER AND CONTROL CABLE TYPE YY (0.75MM 2 TO 1.5MM 2 )
70 70 FLEXIBLE CABLES TYPE YY CONTROL CABLES Plain annealed flexible copper conductors, PVC insulated, PVC sheathed. Grey. 300/500 volts grade, generally to BS6500 and VDE CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER SIZE (MM) (MM) YY2X2/ / /16 YY3X2/ / S YY4X2/ / S YY5X2/ / S YY7X2/ / S YY8X2/ / YY12X2/ / YY18X2/ / YY25X2/ / YY34X2/ / YY3X / S YY4X / S YY5X / YY7X / YY3X / YY4X / YY5X / YY7X / YY3X / YY4X / YY5X / YY3X / YY4X / YY5X / YY3X / YY4X / YY5X / YY4X / YY5X / YY4X / S -5 to +70 C. Static - 6 x overall diameter. Flexing - 15 x overall diameter. 2 core - Black with White numbers. 3 core and above - Black with White numbers plus Green/Yellow. temperatures below -5 C. Also available with coloured cores as follows: 2 core - Blue, Brown. 3 core - Blue, Brown, Green/Yellow. 4 core - Blue, Brown, Black, Green/Yellow (ccc standard stock) as per Cenelec HD 308 four core is available in an alternative core identification - brown, black, grey, green/yellow. 5 core - Blue, Brown, Black, Grey, Green/Yellow. 7 core - Blue, Brown, Black, Grey, White, Red, Green/Yellow. PVC INSULATED FLEXIBLE POWER AND CONTROL CABLE TYPE YY (2.5MM 2 TO 50MM 2 )
71 71 TYPE SY CONTROL CABLES Plain annealed flexible copper conductors, PVC insulated, extruded PVC bedding, galvanised steel wire braid armour, transparent PVC outer sheath. 300/500 volts grade generally to BS6500 and VDE 0250 class 5. CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER SIZE (MM) (MM) SY2X/ / /16 SY3X/ / /16 SY4X/ / /16 SY5X/ / /16 SY7X/ / /16 SY12X/ / S SY18X/ / S SY25X/ / S SY34X/ / SY2X / /16 SY3X / /16 SY4X / /16 SY5X / /16 SY7X / /16 SY12X / S SY18X / SY25X / SY34X / SY50X / SY2X1/ / /16 SY3X1/ / /16 SY4X1/ / /16 SY5X1/ / /16 SY7X1/ / /16 SY12X1/ / S SY18X1/ / SY25X1/ / SY34X1/ / SY50X1/ / SY2X2/ / /16 SY3X2/ / /16 SY4X2/ / /16 SY5X2/ / S SY7X2/ / S SY12X2/ / SY18X2/ / SY25X2/ / SY34X2/ / FLEXIBLE CABLES -5 to +70 C. Static - 10 x overall diameter. Flexing - 20 x overall diameter. 2 core - Black with White numbers. 3 core and above - Black with White numbers plus Green/Yellow. temperatures below -5 C. Also available with coloured cores as follows: 2 core - Blue, Brown. 3 core - Blue, Brown, Green/Yellow. 4 core - Blue, Brown, Black, Green/Yellow (ccc standard stock) as per Cenelec HD 308 four core is available in an alternative core identification - brown, black, grey, green/yellow. 5 core - Blue, Brown, Black, Grey, Green/Yellow. PVC INSULATED BRAIDED FLEXIBLE CONTROL CABLE TYPE SY (0.75MM 2 TO 2.5MM 2 )
72 72 FLEXIBLE CABLES TYPE SY CONTROL CABLES Plain annealed flexible copper conductors, PVC insulated, extruded PVC bedding, galvanised steel wire braid armour, transparent PVC outer sheath. 300/500 volts grade generally to BS6500 and VDE 0250 class 5. CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER SIZE (MM) (MM) SY3X / S SY4X / S SY5X / SY7X / SY3X / S SY4X / S SY5X / SY7X / SY3X / SY4X / SY5X / SY3X / SY4X / SY5X / SY4X / SY5X / SY4X / SY5X / SY4X / SY4X / S SY4X / to +70 C. Static - 10 x overall diameter. Flexing - 20 x overall diameter. 2 core - Black with White numbers. 3 core and above - Black with White numbers plus Green/Yellow. temperatures below -5 C. Also available with coloured cores as follows: 2 core - Blue, Brown. 3 core - Blue, Brown, Green/Yellow. 4 core - Blue, Brown, Black, Green/Yellow (ccc standard stock) as per Cenelec HD 308 four core is available in an alternative core identification - brown, black, grey, green/yellow. 5 core - Blue, Brown, Black, Grey, Green/Yellow. PVC INSULATED BRAIDED FLEXIBLE CONTROL CABLE TYPE SY (4MM 2 TO 95MM 2 )
73 73 TYPE CY CONTROL CABLES Plain annealed flexible copper conductors, PVC insulated, mylar taped, tinned copper wire braid screen, PVC outer sheath. Grey. 300/500 volts grade generally to BS6500 and VDE CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER SIZE (MM) (MM) BRASS A2 CY2X/ / /16 CY3X/ / /16 CY4X/ / /16 CY5X/ / /16 CY7X/ / /16 CY2X/ / /16 CY3X/ / /16 CY4X/ / /16 CY5X/ / /16 CY7X/ / /16 CY12X/ / S CY18X/ / CY25X/ / CY2X / /16 CY3X / /16 CY4X / /16 CY5X / /16 CY7X / /16 CY12X / S CY18X / CY25X / CY34X / CY2X1/ / /16 CY3X1/ / /16 CY4X1/ / /16 CY5X1/ / S CY7X1/ / CY12X1/ / CY18X1/ / CY25X1/ / CY34X1/ / CY42X1/ / CY2X2/ / /16 CY3X2/ / /16 CY4X2/ / S CY5X2/ / S CY7X2/ / S CY12X2/ / CY2X / S CY3X / S CY4X / S CY5X / S CY4X / S CY4X / CY4X / FLEXIBLE CABLES PVC INSULATED BRAID SCREENED FLEXIBLE POWER AND CONTROL CABLE TYPE CY (0.75MM 2 TO 16MM 2 ) Static to +80 C. Flexing - -5 to +70 C. Static - 6 x overall diameter. Flexing - 15 x overall diameter. 2 core - Black with White numbers. 3 core and above - Black with White numbers plus Green/Yellow. temperatures below -5 C. Also available with coloured cores as follows: 2 core - Blue, Brown. 3 core - Blue, Brown, Green/Yellow. 4 core - Blue, Brown, Black, Green/Yellow o(ccc standard stock) as per Cenelec HD 308 four core is available in an alternative core identification - brown, black, grey, green/yellow. 5 core - Blue, Brown, Black, Grey, Green/Yellow.
74 74 FLEXIBLE CABLES TYPE YY CONTROL CABLES LSZH Plain annealed flexible copper conductors, low smoke and zero halogen (LSZH) insulated, low smoke and zero halogen (LSZH) sheathed. Grey. 300/500 volts grade, generally to BS6500 and VDE CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER SIZE (MM) (MM) YY2X/75LSF / /16 YY3X/75LSF / /16 YY4X/75LSF / /16 YY5X/75LSF / /16 YY2X1LSF / /16 YY3X1LSF / /16 YY4X1LSF / /16 YY5X1LSF / /16 YY2X1/5LSF / /16 YY3X1/5LSF / /16 YY4X1/5LSF / /16 YY5X1/5LSF / S YY7X1/5LSF / S YY12X1/5LSF / YY18X1/5LSF / YY25X1/5LSF / YY34X1/5LSF / YY2X2/5LSF / /16 YY3X2/5LSF / S YY4X2/5LSF / S YY5X2/5LSF / S YY3X4LSF / S YY4X4LSF / S YY5X4LSF / YY3X6LSF / YY4X6LSF / YY5X6LSF / YY3X10LSF / YY4X10LSF / YY5X10LSF / YY3X16LSF / YY4X16LSF / YY3X25LSF / to +70 C Static - 6 x Overall Diameter Flexible - 15 x Overall Diameter 2 Core - Black with white numbers 3 Core and above Black with white numbers plus Green/Yellow temperatures below -5 C. TYPE CY CONTROL CABLES LSZH Plain annealed flexible copper conductors, low smoke and zero halogen (LSZH) insulated, mylar taped, tinned copper wire braid, low smoke and zero halogen (LSZH) outer sheath. Grey. 300/500 volts grade, generally to BS6500 and VDE CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER SIZE (MM) (MM) CY2X/75LSF / /16 CY3X/75LSF / /16 CY4X/75LSF / /16 CY5X/75LSF / /16 CY2X1/5LSF / /16 CY3X1/5LSF / /16 CY4X1/5LSF / /16 CY5X1/5LSF / /16 LSZH SHEATHED POWER AND CONTROL CABLE TYPE YY (0.75MM 2 TO 25MM 2 ) AND TYPE CY (0.75MM 2 TO 1.5MM 2 ) -5 to 70 C Static - 6 x Overall Diameter Flexible - 15 x Overall Diameter 2 Core - Black with White numbers 3 Core and above Black with White numbers plus Green/Yellow temperatures below -5 C. Also available with coloured cores as follows: 2 core - Blue, Brown. 3 core - Blue, Brown, Green/Yellow. 4 core - Blue, Brown, Black, Green/Yellow (ccc standard stock) as per Cenelec HD 308 four core is available in an alternative core identification - brown, black, grey, green/yellow. 5 core - Blue, Brown, Black, Grey, Green/Yellow.
75 75 TRI-RATED EQUIPMENT WIRES Plain annealed stranded circular copper conductors, circular high temperature PVC outer sheath. UL & CSA approved also to BS /1000 volts grade. Flame propagation to BS EN and IEC CCC CONDUCTOR STRANDING WEIGHT OVERALL GLAND CODE SIZE (MM 2 ) (MM) KG/KM DIAMETER SIZE (MM) (MM) TRI0/ / TRI/ / TRI / TRI1/ / /16 TRI2/ / /16 TRI / /16 TRI / /16 TRI / /16 TRI / S TRI / S TRI / TRI / TRI / TRI / TRI / BI / BI / BI / BI / S BI / FLEXIBLE CABLES -30 to +105 C. temperatures below 0 C. Standard colours available: 0.5mm 2-2.5mm 2 - Brown, Black, Grey, Blue, Green/Yellow, Red, Yellow, White, Orange, Pink, Violet. 4.0mm 2-16mm 2 - Brown, Black, Grey, Blue, Green/Yellow, Red, Yellow, White. 25.0mm 2-120mm 2 - Brown, Black, Grey, Blue, Green/Yellow, Red, Yellow. 150mm 2 - Black, Green/Yellow. 185mm 2-400mm 2 - Black. TRI-RATED SWITCHGEAR AND CONTROL PANEL WIRE (0.5MM 2 TO 400MM 2 )
76 76 FLEXIBLE CABLES LOW SMOKE ZERO HALOGEN SHEATHED FLEXIBLE CABLE (1.5MM 2 TO 240MM 2 ) PVC INSULATED PVC SHEATHED FLEXIBLE CABLE (6MM 2 TO 400MM 2 ) 2491B/6701B LSZH FLEXIBLE SINGLE CORES Flexible plain annealed copper conductor, low smoke zero halogen (LSZH) outer sheath to BS mm/1.0mm rated at 300/500 volts grade, harmonised code HO5Z-K. 1.5mm to 240mm rated at 450/750 volts grade, harmonised code HO7Z-K. Fire resistant to BS EN :2001 (formerly BS4066:PT1). CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL CODE SIZE (MM) CORES (KG/KM) DIAMETER 2491B/ / B / B1/ / B2/ / B / B / B / B / B / B / B / B / B / B / B / B / B / to + 90 C up to 35mm2-3 x Overall Diameter 50mm2 and above - 4 x Overall Diameter Standard colours available: 1.5mm to 6mm - Black, Blue, Brown, Grey, Orange, White, Red, Yellow, Green/Yellow. 10mm2-240mm2 - Black, Blue, Brown, Grey. SINGLE CORE PVC FLEXIBLE MAINS CABLES Plain annealed flexible copper conductor, PVC insulated PVC sheathed, 450/750 volts, generally to BS6004 & IEC Flame propogation to BS4066 PT1 & IEC332 PT1. CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER SIZE (MM) (MM) 6381Y / / Y / S 6381Y / S 6381Y / Y / Y / Y / Y / Y / Y / Y / Y / Y / Y / S -15 to +70 C. Up to 50mm 3 x overall diameter. Over 70mm 5 x overall diameter. Standard core colours available: Black, grey, blue, brown, green/yellow. temperatures below 0 C.
77 77 SOLAR ENERGY CABLES Electroltic annealed tinned flexible copper conductor, halogen free thermosetting rubber insulation, type EI6 according to EN and table 4 of the TUV standard, halogen free thermosetting rubber outer sheath, type EM8 according to EN and table 4 of the TUV standard. Black. CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL CODE SIZE (MM) CORES (KG/KM) DIAMETER SOLAR1X1/5BK / SOLAR1X2/5BK / SOLAR1X4BK / SOLAR1X6BK / SOLAR1X10BK / SOLAR1X16BK / SOLAR1X25BK / SOLAR1X35BK / FLEXIBLE CABLES Characteristics. Nominal voltage: AC: 0,6/1 kv; DC: 1,8 kv Ambient temperature range: -40 C to + 90 ºC. Maximum conductor temperature: 120 ºC. Maximum short-circuit temperature: 250 C (maximum 5 s). *Minimum bending radius (fixed): 5 x cable Ø. No flame propagation: EN / IEC No fire propagation: EN / IEC Halogen free: according to EN / IEC HCl content < 0,5%. ph > 4,3; conductivity < 10!S/mm. Smoke density: light transmittance > 60% (according to EN / IEC 61034). SOLAR ENERGY CABLES
78 78 FLEXIBLE CABLES FLEXIBLE MAINS AND CONTROL CABLES EPR,CSP Tinned annealed flexible copper conductors, ethylene propylene rubber (EPR) insulated, chlorosulphonated polyethylene (CSP) outer sheath. 300/500 volts grade to BS6500. Black or White. Heat and oil resistant and flame retardant (HOFR). Flame retardant to BS EN (BS EN ). Harmonised code H07BN4-F. CCC CONDUCTOR STRANDING NO. OF WEIGHT MEAN OVERALLDIAMETER CODE SIZE (MM 2 ) (MM) CORES KG/KM (MM) LOWER LIMIT UPPER LIMIT 3182TQ/ / TQ/ / TQ/ / TQ / TQ / TQ / TQ1/ / TQ1/ / TQ1/ / TQ1/ / TQ1/ / TQ1/ / TQ1/ / /12TQ1/ / /16TQ1/ / /20TQ1/ / /27TQ1/ / /37TQ1/ / TQ2/ / TQ2/ / TQ2/ / TQ2/ / TQ2/ / TQ2/ / /12TQ2/ / /16TQ2/ / /20TQ2/ / /27TQ2/ / /37TQ2/ / to +90 C. Fixed - 6 x overall diameter. Flexing - 15 x overall diameter. 2 core - Blue, Brown. 3 core - Blue, Brown, Green/Yellow. 4 core - Grey, Black, Brown, Green/Yellow. 5 core - Grey, Black, Brown, Blue, Green/Yellow. 6 core and above - Black with White numbers plus Green/Yellow. temperatures below -25 C. EPR INSULATED HOFR SHEATHED FLEXIBLE POWER AND CONTROL CABLE (0.75MM 2 TO 2.5MM 2 )
79 79 FLEXIBLE MAINS CABLES EPR,CSP Tinned annealed flexible copper conductors, ethylene propylene rubber (EPR) insulated, chlorosulphonated polyethylene (CSP) outer sheath. Black. 450/750 volts grade to BS7919. Heat and oil resistant and flame retardant (HOFR). Flame retardant to BS EN (BS EN ). Harmonised code H07BN4-F. FLEXIBLE CABLES CCC CONDUCTOR STRANDING NO. OF WEIGHT MEAN OVERALLDIAMETER CODE SIZE (MM 2 ) (MM) CORES KG/KM (MM) LOWER LIMIT UPPER LIMIT 6381TQ / TQ / TQ / TQ / TQ / TQ / /12TQ / TQ6 6 84/ TQ6 6 84/ TQ6 6 84/ TQ6 6 84/ TQ6 6 84/ TQ6 6 84/ TQ6 6 84/ TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / to +90 C. Fixed - 6 x overall diameter. Flexing - 7 x overall diameter. 2 core - Blue, Brown. 3 core - Blue, Brown, Green/Yellow. 4 core - Grey, Black, Brown, Green/Yellow. 5 core - Grey, Black, Brown, Blue, Green/Yellow. 6 core and above - Black with White numbers plus Green/Yellow. temperatures below -25 C. EPR INSULATED HEAVY DUTY HOFR SHEATHED FLEXIBLE MAINS CABLE (4MM 2 TO 16MM 2 )
80 80 FLEXIBLE CABLES FLEXIBLE MAINS CABLES EPR,CSP Tinned annealed flexible copper conductors, ethylene propylene rubber (EPR) insulated, chlorosulphonated polyethylene (CSP) outer sheath. Black. 450/750 volts grade to BS7919. Heat and oil resistant and flame retardant (HOFR). Flame retardant to BS EN (BS EN ). Harmonised code H07BN4-F. CCC CONDUCTOR STRANDING NO. OF WEIGHT MEAN OVERALLDIAMETER CODE SIZE (MM 2 ) (MM) CORES KG/KM (MM) LOWER LIMIT UPPER LIMIT 6381TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / to +90 C. Fixed - 5 x overall diameter. Flexing - 7 x overall diameter. 2 core - Blue, Brown. 3 core - Blue, Brown, Green/Yellow. 4 core - Grey, Black, Brown, Green/Yellow. 5 core - Grey, Black, Brown, Blue, Green/Yellow. 6 core and above - Black with White numbers plus Green/Yellow. temperatures below -25 C. EPR INSULATED HOFR SHEATHED POWER AND CONTROL CABLE (25MM 2 TO 630MM 2 )
81 81 FLEXIBLE MAINS AND CONTROL CABLES HO7RN-F Plain annealed flexible copper conductors, rubber insulated, heavy duty polychloroprene (PCP) outer sheath 450/750 volts grade. Black. Harmonized code type HO7RN-F. Flame propagation to EN CCC CONDUCTOR STRANDING NO. OF WEIGHT MEAN OVERALLDIAMETER CODE SIZE (MM 2 ) (MM) CORES KG/KM (MM) LOWER LIMIT UPPER LIMIT 3182P / P / P / P1/ / P1/ / P1/ / P1/ / P1/ / /12P1/ / P2/ / P2/ / P2/ / P2/ / P2/ / /12P2/ / P / P / P / P / P / P / P / P / P / P / P / P / P / P / P / P / P / P / P / P / P / P / P / P / P / P / P / P / P / P / P / FLEXIBLE CABLES RUBBER INSULATED NEOPRENE SHEATHED FLEXIBLE POWER CABLE (1MM 2 TO 50MM 2 ) -25 to +60 C. Can be supplied suitable for up to 85 C upon special request. Static - 6 x overall diameter. Flexing - 15 x overall diameter. 2 core - Blue, Brown. 3 core - Blue, Brown, Green/Yellow. 4 core - Grey, Black, Brown, Green/Yellow. 5 core - Grey, Black, Brown, Blue, Green/Yellow. 6 core and above - Black with White numbers plus Green/Yellow. temperatures below 0 C.
82 82 FLEXIBLE CABLES FLEXIBLE MAINS AND CONTROL CABLES HO7RN-F Plain annealed flexible copper conductors, rubber insulated, heavy duty polychloroprene (PCP) outer sheath 450/750 volts grade. Black. Harmonized code type HO7RN-F. Flame propagation to EN CCC CONDUCTOR STRANDING NO. OF WEIGHT MEAN OVERALLDIAMETER CODE SIZE (MM 2 ) (MM) CORES KG/KM (MM) LOWER LIMIT UPPER LIMIT 6381P / P / P / P / P / P / P / P / P / P / P / P / P / P / P / P / P / P / P / P / P / P / P / P / to +60 C. Can be supplied suitable for up to 85 C upon special request. Static - 6 x overall diameter. Flexing - 15 x overall diameter. 2 core - Blue, Brown. 3 core - Blue, Brown, Green/Yellow. 4 core - Grey, Black, Brown, Green/Yellow. 5 core - Grey, Black, Brown, Blue, Green/Yellow. 6 core and above - Black with White numbers plus Green/Yellow. temperatures below 0 C. RUBBER INSULATED NEOPRENE SHEATHED FLEXIBLE POWER CABLE (70MM 2 TO 630MM 2 )
83 83 TOUGH RUBBER SHEATH FLEXIBLE CORDS Flexible tinned annealed copper conductors, ethylene propylene rubber insulated, tough rubber sheath. Black. 300/500 volts grade to BS6500 and BS7919. CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER SIZE (MM) (MM) 3182/ / / / / / / / / / / / / / / / / S 31831/ / S 31841/ / S 31851/ / S 31822/ / S 31832/ / S 31842/ / / / FLEXIBLE CABLES EPR INSULATED TOUGH RUBBER SHEATH (0.75MM 2 TO 2.5MM 2 ) EPR INSULATED BRAIDED SCREEN FLEXIBLE MAINS AND CONTROL CABLE (1.0MM 2 TO 16MM 2 ) +60 C. 6 x overall diameter. 2 core - Blue, Brown. 3 core - Blue, Brown, Green/Yellow. 4 core - Grey, Black, Brown, Green/Yellow. 5 core - Grey, Black, Brown, Blue, Green/Yellow. BRAIDED TOUGH RUBBER SHEATH FLEXIBLE CORDS Flexible tinned annealed copper conductors, ethylene propylene rubber insulated, chlorosulphonated polyethylene bedding (CSP), tinned copper wire braid screen, chlorosulphonated polyethylene (CSP) outer sheath. 300/500 volts grade to BS6500/75 and 450/750 Volts grade to BS6007/75 (where applicable). Black. Flame propogation to BS 4066 PT1 and IEC 332 PT1. Heat and oil resistant and flame retardant (HOFR). CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER SIZE (MM) (MM) 3802TQ / / TQ / / TQ / / TQ1/ / / TQ1/ / S 3804TQ1/ / S 3802TQ2/ / S 3803TQ2/ / TQ2/ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / to +90 C. 8 x overall diameter. 2 core - Blue, Brown. 3 core - Blue, Brown, Green/Yellow. 4 core - Grey, Black, Brown, Blue, Green/Yellow. temperatures below 0 C.
84 84 FLEXIBLE CABLES COIL END LEAD FLEXIBLE MAINS CABLES Flexible tinned annealed copper conductors composite ethylene propylene rubber chlorosulphonated polyethylene (EPR-CSP) insulation to BS6195/69 Type 4. A. 300/500 volts grade E. 3800/6600 volts grade C. 600/1000 volts grade F. 6350/11000 volts grade D. 1900/3300 volts grade CONDUCTOR RADIAL THICKNESS OF INSULATION VOLTAGE CATEGORY SIZE STRANDING MAX APPROX. A C D E F CCC CODE (MM 2 ) (MM 2 ) DIA. OF DIA. OF (MM) (MM) (MM) (MM) (MM) WIRES COND. (MM) (MM) / / / TYPE 4 1/ / TYPE 4 2/ / TYPE / TYPE / TYPE / TYPE / TYPE / TYPE / TYPE / TYPE / TYPE / TYPE / TYPE / TYPE / TYPE / TYPE / TYPE / TYPE / MINIMUM OVERALL DIAMETER WEIGHT VOLTAGE CATEGORY VOLTAGE CATEGORY CCC CODE A C D E F A C D E F (MM) (MM) (MM) (MM) (MM) KG/KM KG/KM KG/KM KG/KM KG/KM TYPE 4 1/ TYPE 4 2/ TYPE TYPE TYPE TYPE TYPE TYPE TYPE TYPE TYPE TYPE TYPE TYPE TYPE TYPE TYPE TYPE EPR INSULATED FLEXIBLE COIL LEAD (0.5MM 2 TO 400MM 2 ) -20 to +90 C. 6 x overall diameter. temperatures below -25 C.
85 85 WELDING CABLES 0361TQ Tinned annealed flexible circular copper conductors, ethylene propylene rubber (EPR) insulated, chlorosulphonated polyethylene (CSP) outer sheath. Orange. Ref 0361TQ. To BS638 Part 4. Flame retardant to BS EN (BS EN ). CCC CONDUCTOR STRANDING WEIGHT OUTSIDE GLAND CODE SIZE (MM 2 ) (MM) KG/KM DIAMETER SIZE (MM) (MM) 0361TQ16OR / S 0361TQ25OR / TQ35OR / TQ50OR / TQ70OR / TQ95OR / TQ120OR / TQ185OR / FLEXIBLE CABLES -20 to +85 C. 8 x overall diameter. EPR INSULATED FLEXIBLE WELDING CABLE TYPE 0361TQ (16MM 2 TO 185MM 2 )
86 86 FLEXIBLE CABLES RUBBER FLATFORM CABLES Flexible plain copper conductors, thermoplastic rubber insulated (TPR) thermoplastic outer sheath (TPR). Black. 600/1000 volts grade. CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL MAX CURRENT CODE SIZE (MM 2 ) (MM) CORES KG/KM DIMENSIONS RATINGS (MM) (AMPS) FLAT4X1/5R / X5 22 FLAT12X1/5R / X5 12 FLAT4X2/5R / X6 30 FLAT7X2/5R / X7 20 FLAT12X2/5R / X6 20 FLAT4X4R 4 56/ X7 40 FLAT4X6R 6 84/ X7 52 FLAT4X10R 10 80/ X9 70 FLAT4X16R / X10 95 FLAT4X25R / X FLAT4X35R / X FLAT4X50R / X FLAT4X70R / X to +85 C. 10 x overall diameter. 4 core - Black, Grey, Brown, Green/Yellow. 7 and 12 core - Black cores with White numbers and one Green/Yellow. temperatures below 0 C. PVC FLATFORM CABLES Flexible plain copper conductors, PVC insulated, special PVC outer sheath. Black. 450/750 volts grade type H07VVH6-F. CENELEC HD 359 S2 IEC 227 part 6. CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL MAX CURRENT CODE SIZE (MM 2 ) (MM) CORES KG/KM DIMENSIONS RATINGS (MM) (AMPS) FLAT4X1/5V / X5 20 FLAT12X1/5V / X5 11 FLAT4X2/5V / X6 27 FLAT12X2/5V / X6 16 FLAT4X4V 4 56/ X7 36 FLAT4X6V 6 84/ X7 48 FLAT4X10V 10 80/ X9 63 FLAT4X16V / X11 85 FLAT4X25V / X FLAT4X35V / X FLAT4X50V / X FLAT4X70V / X FLAT4X95V / X RUBBER INSULATED FLAT CABLE (1.5MM 2 TO 70MM 2 ) AND PVC INSULATED FLAT CABLE (1.5MM 2 TO 95MM 2 ) -25 to +70 C. 10 x overall diameter. 4 core - Black, Grey, Brown, Green/Yellow. 12 core - Black cores with white numbers and one Green/Yellow. temperatures below 0 C.
87 87 SILICON FLEXIBLE CABLES SIHF Flexible tinned annealed copper conductors, silicone insulated, silicone outer sheath. 300/500 volts grade to VDE 0250 PT816. CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER SIZE (MM) (MM) BIHF2X/ / /16 BIHF3X/ / /16 BIHF4X/ / /16 BIHF5X/ / S BIHF7X/ / S BIHF2X / /16 BIHF3X / /16 BIHF4X / S BIHF5X / S BIHF7X / S BIHF2X1/ / /16 BIHF3X1/ / /16 BIHF4X1/ / S BIHF5X1/ / S BIHF7X1/ / S BIHF2X2/ / S BIHF3X2/ / S BIHF4X2/ / S BIHF5X2/ / S BIHF7X2/ / FLEXIBLE CABLES -60 to +180 C. Fixed - 5 x overall diameter. Flexing - 15 x overall diameter. 2 core - Blue, Brown. 3 core - Blue, Brown, Green/Yellow. 4 core - Grey, Black, Brown, Green/Yellow. 5 core and above - Grey, Black, Brown, Blue, Green/Yellow 6 core and above - Black with White numbers plus Green/Yellow. temperatures below 0 C. SILICONE INSULATED FLEXIBLE CABLE (0.75MM 2 TO 2.5MM 2 )
88
89 89 INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES
90 90 INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES INSTRUMENTATION AND CONTROL CABLES - PAS5308 PAS5308 PART 1, TYPE 1 CONSTRUCTION, OVERALL SCREENED Plain annealed flexible copper conductors, polyethylene insulated, laid up to form pairs, collective aluminium/mylar tape screen complete with 0.5mm 2 drain wire, PVC outer sheath reduced propagation, Blue or Black. Flame propagation to BS4066 PT1, BS EN and IEC PAS5308 PART 2, TYPE 1 CONSTRUCTION, OVERALL SCREENED Plain annealed flexible copper conductors, PVC insulated, laid up to form pairs, collective aluminium/mylar tape screen complete with 0.5mm 2 drain wire, PVC outer sheath reduced propagation. Blue or Black. Flame propagation to BS4066 PT1, BS EN and IEC CCC CODE CONDUCTOR STRANDING NO. OF WEIGHT OUTSIDE BRASS PT1 PT2 SIZE (MM 2 ) (MM) PAIRS KG/KM DIAMETER A2 (MM) GLAND / / / / / / / / / S / TRIPLE / / / / / / / / / / S / TRIPLE / / / / S / / / N/A N/A 1.5 7/ S N/A N/A 1.5 7/ S / TRIPLE S PAS5308 PART 1, TYPE 1 CONSTRUCTION, OVERALL SCREENED LSZH Plain annealed flexible copper conductors, XLPE insulated, laid up to form pairs, collective aluminium/mylar tape screen complete with 0.5mm 2 drain wire, low smoke zero halogen (LSZH) sheath, Blue or Black, to PAS5308 Part 1, Type 1 LSZH. CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL BRASS CODE SIZE (MM 2 ) (MM) PAIRS KG/KM DIAMETER A2 (MM) GLAND / / / / / / / / INSTRUMENTATION AND CONTROL CABLES NON-ARMOURED WITH COLLECTIVE SCREEN (0.5MM 2 TO 1.5MM 2 ) -20 to +65 C. 5 x overall diameter. Part 1 colour code chart on page 96. Part 2 colour code chart on page 97. temperatures below 0 C.
91 91 INSTRUMENTATION AND CONTROL CABLES - PAS5308 PAS5308 PART 1, TYPE 1 CONSTRUCTION, INDIVIDUALLY SCREENED Plain annealed flexible copper conductors, polyethylene insulated, laid up to form pairs, each pair individually aluminium/mylar foil tape screened, complete with 0.5mm 2 drain wire, collective aluminium/mylar foil tape screen complete with 0.5mm 2 drain wire, PVC outer sheath reduced propagation. Blue or Black. Flame propagation to BS4066 PT1, BS EN and IEC PAS5308 PART 2, TYPE 1 CONSTRUCTION, INDIVIDUALLY SCREENED Plain annealed flexible copper conductors, PVC insulated, laid up to form pairs, each pair individually aluminium/mylar foil tape screened complete with 0.5mm 2 drain wire, collective aluminium/mylar foil tape screen complete with 0.5mm 2 drain wire, PVC outer sheath reduced propagation. Blue or Black. Flame propagation to BS4066 PT1, BS EN and IEC CCC CODE CONDUCTOR STRANDING NO. OF WEIGHT OUTSIDE BRASS PT1 PT2 SIZE (MM 2 ) (MM) PAIRS KG/KM DIAMETER A2 (MM) GLAND / S / / / / / * / / / / / S / S / / / / S / / INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES PAS5308 PART 1, TYPE 1 CONSTRUCTION, INDIVIDUALLY SCREENED LSZH Plain annealed flexible copper conductors, XLPE insulated, laid up to form pairs, each pair individually aluminium/mylar tape screened. Complete with 0.5mm 2 drain wire, collective aluminium/mylar tape screen complete with 0.5mm 2 drain wire, low smoke zero halogen (LSZH) outer sheath, Black or Blue, generally to PAS5308 Part 1, Type 1 LSZH. CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL BRASS CODE SIZE (MM 2 ) (MM) PAIRS KG/KM DIAMETER A2 (MM) GLAND / / / / / S INSTRUMENTATION AND CONTROL CABLES NON-ARMOURED WITH INDIVIDUAL AND COLLECTIVE SCREENS (0.5MM 2 TO 1.5MM 2 ) -20 to +65 C. 5 x overall diameter. Part 1 colour code chart on page 96. Part 2 colour code chart on page 97. temperatures below 0 C.
92 92 INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES INSTRUMENTATION AND CONTROL CABLES - PAS5308 PAS5308 PART 1, TYPE 2 CONSTRUCTION, OVERALL SCREENED Plain annealed flexible copper conductors, polyethylene insulated, laid up to form pairs, collective aluminium/mylar foil tape screen, complete with 0.5mm 2 drain wire, Polytheylene bedding, galvanised steel wire armour, PVC outer sheath reduced propagation. Blue or Black. Flame propagation to BS4066 Parts 1 and 3, BS EN 50265, BS EN 50266, IEC and IEC 332-3C. PAS5308 PART 2, TYPE 2 CONSTRUCTION, OVERALL SCREENED Plain annealed flexible copper conductors, PVC insulated, laid up to form pairs, collective aluminium/mylar foil tape screen complete with 0.5mm 2 drain wire, Polytheylene bedding, galvanised steel wire armour, PVC outer sheath reduced propagation. Blue or Black. Flame propagation to BS4066 Parts 1 and 3, BS EN 50265, BS EN 50266, IEC and IEC 332-3C. CCC CODE CONDUCTOR STRANDING No. OF WEIGHT OVERALL GLAND CLEAT PT1 PT2 SIZE (MM 2 ) (MM) PAIRS KG/KM DIAMETER SIZE SIZE (MM) (MM) (MM) / / / S / / / / / S / TRIPLE / / / / S / / / / / S / TRIPLE S / S / S / / / / S / S TC / TRIPLE S / S / / / / / TRIPLE S 0.6 PAS5308 PART 1, TYPE 2 CONSTRUCTION, OVERALL SCREENED LSZH Plain annealed flexible copper conductors, XLPE insulated, laid up to form pairs, collective aluminium/mylar foil tape screen, complete with 0.5mm 2 drain wire, low smoke zero halogen bedding (LSZH), galvanised steel wire armour, low smoke zero halogen (LSZH) sheath, Black or Blue, generally to PAS5308 Part 1, Type 2 LSZH. CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND CLEAT CODE SIZE (MM 2 ) (MM) PAIRS KG/KM DIAMETER SIZE SIZE (MM) (MM) (MM) / / / S / / / / / S / S / S / / / INSTRUMENTATION AND CONTROL CABLES ARMOURED WITH COLLECTIVE SCREEN (0.5MM 2 TO 2.5MM 2 ) -20 to +65 C. 6 x overall diameter.. Part 1 colour code chart on page 96. Part 2 colour code chart on page 97. temperatures below 0 C.
93 93 INSTRUMENTATION AND CONTROL CABLES - PAS5308 PAS5308 PART 1, TYPE 2 CONSTRUCTION, INDIVIDUALLY SCREENED Plain annealed flexible copper conductors, polyethylene insulated, laid up to form pairs, each pair individually aluminium/mylar foil tape screened, complete with 0.5mm 2 drain wire, collective aluminium/mylar foil tape screen, complete with 0.5mm 2 drain wire, polyethylene bedding, galvanised steel wire armour, PVC outer sheath reduced propagation. Blue or Black. Flame propagation to BS4066 Parts 1 and 3, BS EN 50265, BS EN 50266, IEC and IEC 332-3C. PAS5308 PART 2, TYPE 2 CONSTRUCTION, INDIVIDUALLY SCREENED Plain annealed flexible copper conductors, PVC insulated, laid up to form pairs, each pair individually aluminium/mylar foil tape screened, complete with 0.5mm 2 drain wire, collective aluminium/mylar foil tape screen complete with 0.5mm 2 drain wire, PVC bedding, galvanised steel wire armour, PVC outer sheath reduced propagation. Blue or Black. Flame propagation to BS4066 Parts 1 and 3, BS EN 50265, BS EN 50266, IEC and IEC 332-3C. CCC CODE CONDUCTOR STRANDING No. OF WEIGHT OVERALL GLAND CLEAT PT1 PT2 SIZE (MM 2 ) (MM) PAIRS KG/KM DIAMETER SIZE SIZE (MM) (MM) (MM) / / / / / S / TC / / / / / S / S TC / / / / S / TC / TC10 INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES PAS5308 PART 1, TYPE 2 CONSTRUCTION, INDIVIDUALLY SCREENED LSZH Plain annealed flexible copper conductors, XLPE insulated, laid up to form pairs, each pair individually aluminium/mylar foil tape screened, complete with 0.5mm 2 drain wire, collective aluminium/mylar foil tape screen, complete with 0.5mm 2 drain wire, low smoke zero halogen (LSZH) bedding, galvanised steel wire armour, low smoke zero halogen (LSZH) sheath, Blue or Black, generally to PAS5308 Part 1, Type 2 LSZH. CCC CODE CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND CLEAT SIZE (MM 2 ) (MM) PAIRS KG/KM DIAMETER SIZE SIZE (MM) (MM) (MM) / / / / / / / / S 1.8 INSTRUMENTATION AND CONTROL CABLES ARMOURED WITH INDIVIDUAL AND COLLECTIVE SCREEN (0.5MM 2 TO 1.5MM 2 ) -20 to +65 C. 6 x overall diameter. Part 1 colour code chart on page 96. Part 2 colour code chart on page 97. temperatures below 0 C.
94 94 INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES INSTRUMENTATION AND CONTROL CABLES - PAS5308 PAS5308 PART 1, TYPE 3 CONSTRUCTION, OVERALL SCREENED Plain annealed copper conductors, polyethylene insulated, laid up to form pairs, each pair individually aluminium/mylar foil tape screened complete with 0.5mm 2 drain wire, collective aluminium/mylar foil tape screen complete with 0.5mm 2 drain wire, polyethylene bedding, lead sheathed, galvanised steel wire armour, PVC outer sheath reduced propagation. Blue or Black. PAS5308 PART 2, TYPE 3 CONSTRUCTION, OVERALL SCREENED Plain annealed flexible copper conductors, PVC insulated laid up to form pairs, each pair individually aluminium/mylar foil tape screened complete with 0.5mm 2 drain wire, collective aluminium/mylar foil tape screen complete with 0.5mm 2 drain wire, PVC bedding, lead sheathed, galvanised steel wire armour, PVC outer sheath reduced propagation. Blue or Black. CCC CODE CONDUCTOR STRANDING No. OF WEIGHT OVERALL GLAND CLEAT PT1 PT2 SIZE (MM 2 ) (MM) PAIRS KG/KM DIAMETER SIZE SIZE (MM) (MM) (MM) / / / / / / S / S TC / / / / / / S / S TC / / / / / S / / TC10-20 to +63 C. 5 x overall diameter. Part 1 colour code chart on page 96. Part 2 colour code chart on page 97. temperatures below 0 C. INSTRUMENTATION AND CONTROL CABLES LEAD SHEATHED ARMOURED WITH COLLECTIVE SCREEN (0.75MM 2 TO 1.5MM 2 )
95 95 INSTRUMENTATION AND CONTROL CABLES - PAS5308 PAS5308 PART 1, TYPE 3 CONSTRUCTION, INDIVIDUALLY SCREENED Plain annealed flexible copper conductors, polyethylene insulated, laid up to form pairs, collective aluminium/mylar tape screen, complete with 0.5mm 2 drain wire, polyethylene bedding, lead sheathed, galvanised steel wire armour, PVC outer sheath reduced propagation. Blue or Black. Flame propagation to BS4066 Parts 1 and 3, BS EN 50265, BS EN 50266, IEC and IEC 332-3C. PAS5308 PART 2, TYPE 3 CONSTRUCTION, INDIVIDUALLY SCREENED Plain annealed flexible copper conductors, PVC insulated, laid up to form pairs, collective aluminium/mylar foil tape screen complete with 0.5mm 2 drain wire, PVC bedding, lead sheathed, galvanised steel wire armour, PVC outer sheath reduced propagation. Blue or Black. Flame propagation to BS4066 Parts 1 and 3, BS EN 50265, BS EN 50266, IEC and IEC 332-3C. CCC CODE CONDUCTOR STRANDING No. OF WEIGHT OVERALL GLAND CLEAT PT1 PT2 SIZE (MM 2 ) (MM) PAIRS KG/KM DIAMETER SIZE SIZE (MM) (MM) (MM) / / / / S / S / S TC10 N/A N/A 1.0 1/ N/A N/A 1.0 1/ N/A N/A 1.0 1/ N/A N/A 1.0 1/ S 1.8 N/A N/A 1.0 1/ TC9 N/A N/A 1.0 1/ TC / / / S / / S TC / S TC12 INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES -20 to +65 C. 15 x overall diameter. Part 1 colour code chart on page 96. Part 2 colour code chart on page 97. temperatures below 0 C. INSTRUMENTATION AND CONTROL CABLES LEAD SHEATHED ARMOURED WITH INDIVIDUAL AND COLLECTIVE SCREENS (0.75MM 2 TO 1.5MM 2 )
96 96 INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES INSTRUMENTATION AND CONTROL CABLES PAS5308 PART 1 COLOUR CODING PAIR A B PAIR A B NUMBER WIRE WIRE NUMBER WIRE WIRE 1 BLACK BLUE 26 WHITE YELLOW 2 BLACK GREEN 27 RED YELLOW 3 BLUE GREEN 28 ORANGE YELLOW 4 BLACK BROWN 29 BLACK GREY 5 BLUE BROWN 30 BLUE GREY 6 GREEN BROWN 31 GREEN GREY 7 BLACK WHITE 32 BROWN GREY 8 BLUE WHITE 33 WHITE GREY 9 GREEN WHITE 34 RED GREY 10 BROWN WHITE 35 ORANGE GREY 11 BLACK RED 36 YELLOW GREY 12 BLUE RED 37 BLACK VIOLET 13 GREEN RED 38 BLUE VIOLET 14 BROWN RED 39 GREEN VIOLET 15 WHITE RED 40 BROWN VIOLET 16 BLACK ORANGE 41 WHITE VIOLET 17 BLUE ORANGE 42 RED VIOLET 18 GREEN ORANGE 43 ORANGE VIOLET 19 BROWN ORANGE 44 YELLOW VIOLET 20 WHITE ORANGE 45 GREY VIOLET 21 RED ORANGE 46 BLACK TURQUOISE 22 BLACK YELLOW 47 BLUE TURQUOISE 23 BLUE YELLOW 48 GREEN TURQUOISE 24 GREEN YELLOW 49 BROWN TURQUOISE 25 BROWN YELLOW 50 WHITE TURQUOISE For individual screened pairs, identification will be Black/Blue numbered pairs. Two pair collectively screened cables are in quad formation colour coded in rotation, Black, Blue, Green, Brown. Single triple will be Blue, Black, Green. PAS5308 PART 1 CORE IDENTIFICATION
97 97 INSTRUMENTATION AND CONTROL CABLES PAS5308 PART 2 COLOUR CODING PAIR A B PAIR A B NUMBER WIRE WIRE NUMBER WIRE WIRE 1 WHITE BLUE 26 RED/BLUE BLUE 2 WHITE ORANGE 27 RED/BLUE ORANGE 3 WHITE GREEN 28 RED/BLUE GREEN 4 WHITE BROWN 29 RED/BLUE BROWN 5 WHITE GREY 30 RED/BLUE GREY 6 RED BLUE 31 BLUE/BLACK BLUE 7 RED ORANGE 32 BLUE/BLACK ORANGE 8 RED GREEN 33 BLUE/BLACK GREEN 9 RED BROWN 34 BLUE/BLACK BROWN 10 RED GREY 35 BLUE/BLACK GREY 11 BLACK BLUE 36 YELLOW/BLUE BLUE 12 BLACK ORANGE 37 YELLOW/BLUE ORANGE 13 BLACK GREEN 38 YELLOW/BLUE GREEN 14 BLACK BROWN 39 YELLOW/BLUE BROWN 15 BLACK GREY 40 YELLOW/BLUE GREY 16 YELLOW BLUE 41 WHITE/ORANGE BLUE 17 YELLOW ORANGE 42 WHITE/ORANGE ORANGE 18 YELLOW GREEN 43 WHITE/ORANGE GREEN 19 YELLOW BROWN 44 WHITE/ORANGE BROWN 20 YELLOW GREY 45 WHITE/ORANGE GREY 21 WHITE/BLUE BLUE 46 ORANGE/RED BLUE 22 WHITE/BLUE ORANGE 47 ORANGE/RED ORANGE 23 WHITE/BLUE GREEN 48 ORANGE/RED GREEN 24 WHITE/BLUE BROWN 49 ORANGE/RED BROWN 25 WHITE/BLUE GREY 50 ORANGE/RED GREY For individual screened pairs, identification will be White/Blue numbered pairs. Two pair collectively screened cables are in quad formation colour coded in rotation, Black, Blue, Green, Brown. Single triple will be Blue, White, Orange. INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES PAS5308 PART 2 CORE IDENTIFICATION
98 98 INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES INSTRUMENTATION AND CONTROL CABLES BSC (CORUS) STANDARD Plain annealed flexible copper conductors, PVC bedding, tinned annealed copper wire braid screen, PVC bedding, galvanised steel wire armour, PVC outer sheath. Grey. 300/500 volts grade to British Steel specification CES 20 part 4, Type 134. Flame propagation to BS EN and IEC CCC CONDUCTOR STRANDING NO. OF WEIGHT OUTSIDE GLAND SINGLE CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER SIZE CLEAT (MM) (MM) BSC1342C / S 0.6 BSC1343C / S 0.6 BSC1344C / S 0.6 BSC1347C / S 0.7 BSC13412C / BSC13419C / BSC13427C / BSC13437C / to +70 C. 6 x overall diameter. CORE IDENTIFICATION: temperatures below 0 C. NO. OF COLOUR CORES 2 BROWN BLUE 3 BROWN BLUE GREEN/YLW 4 BROWN GREY GREEN/YLW BLACK 7 RED BLUE GREEN YELLOW WHITE BLACK BROWN 12 RED BLUE GREEN YELLOW WHITE BLACK BROWN VIOLET ORANGE PINK TURQUOISE GREY 19 RED BLUE GREEN YELLOW WHITE BLACK BROWN VIOLET ORANGE PINK TURQUOISE GREY RED/BLUE RED/GREEN RED/YELLOW RED/WHITE RED/BLACK RED/BROWN BLUE/YELLOW 27 RED BLUE GREEN YELLOW WHITE BLACK BROWN VIOLET ORANGE PINK TURQUOISE GREY RED/BLUE RED/GREEN RED/YELLOW RED/WHITE RED/BLACK RED/BROWN BLUE/YELLOW BLUE/WHITE BLUE/BLACK BLUE/ORANGE BLUE/GREEN BLUE./GREY GREEN/YLW GREEN/WHITE GREEN/BLACK 37 RED BLUE GREEN YELLOW WHITE BLACK BROWN VIOLET ORANGE PINK TURQUOISE GREY RED/BLUE RED/GREEN RED/YELLOW RED/WHITE RED/BLACK RED/BROWN BLUE/YELLOW BLUE/WHITE BLUE/BLACK BLUE/ORANGE BLUE/GREEN BLUE./GREY GREEN/YLW GREEN/WHITE GREEN/BLACK GRN/ORANGE GREEN/GREY BROWN/YLW BRN/WHITE BRN/BLACK BROWN/GREY VIOLET/YLW VIOLET/BLACK VIOLET/WHT RED/GREY INSTRUMENTATION CABLE TO BRITISH STEEL SPECIFICATION CES20 TYPE 134 (0.75MM 2 )
99 99 INSTRUMENTATION AND CONTROL CABLES BSC (CORUS) STANDARD Tinned annealed flexible copper conductors, PVC insulated and laid up to form pairs, collective aluminium/mylar foil tape screen, complete with 0.5mm 2 drain wire, PVC bedding, galvanised steel wire armour, PVC outer sheath. Orange. 300/500 volts grade. Type 143. Flame propagation to BS EN and IEC CCC CONDUCTOR STRANDING NO. OF WEIGHT OUTSIDE GLAND SINGLE CODE SIZE (MM 2 ) (MM) PAIRS KG/KM DIAMETER SIZE CLEAT (MM) (MM) BSC1431P / / BSC1432P / S 0.5 BSC1435P / BSC14310P / BSC14320P / BSC14330P / BSC14350P / to +70 C. 6 x overall diameter. temperatures below 0 C. CORE IDENTIFICATION ACCORDING TO ENATS 09-6 SECTION 3 PAIR A B PAIR A B NUMBER WIRE WIRE NUMBER WIRE WIRE 1 BLACK BLUE 26 WHITE YELLOW 2 BLACK ORANGE 27 WHITE VIOLET 3 BLACK GREEN 28 BLUE RED 4 BLACK BROWN 29 BLUE YELLOW 5 BLACK GREY 30 BLUE VIOLET 6 BLUE WHITE 31 GREEN RED 7 BLUE ORANGE 32 GREEN YELLOW 8 BLUE GREEN 33 GREEN VIOLET 9 BLUE BROWN 34 RED GREY 10 BLUE GREY 35 RED ORANGE 11 ORANGE WHITE 36 RED YELLOW 12 ORANGE GREEN 37 RED BROWN 13 ORANGE BROWN 38 RED VIOLET 14 ORANGE GREY 39 GREY YELLOW 15 GREEN WHITE 40 GREY VIOLET 16 GREEN BROWN 41 ORANGE YELLOW 17 GREEN GREY 42 ORANGE VIOLET 18 BROWN WHITE 43 YELLOW BROWN 19 BROWN GREY 44 YELLOW VIOLET 20 GREY WHITE 45 BROWN VIOLET 21 BLACK WHITE 46 TURQUOISE BLACK 22 BLACK RED 47 TURQUOISE BLUE 23 BLACK YELLOW 48 TURQUOISE RED 24 BLACK VIOLET 49 TURQUOISE ORANGE 25 WHITE RED 50 TURQUOISE YELLOW INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES INSTRUMENTATION CABLE TO BRITISH STEEL SPECIFICATION CES20 TYPE 143 (0.75MM 2 )
100 100 INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES INTERNAL TELEPHONE CABLES TYPE CW1308 Solid tinned annealed copper conductors, PVC insulated, polyester taped, PVC sheathed. To BPO CW(M) Sheath colour: White. Flame propagation to BS4066 PT1 and IEC 332 PT1. CCC STRANDING No. OF WEIGHT OVERALL GLAND CODE (MM 2 ) PAIRS KGS/KM DIAMETER SIZE (MM) (MM) / / / / / / / / / / / E S / S / S / E / E / E / E / E / E / E / E / E / E E. denotes earth core. -20 to +70 C. CORE IDENTIFICATION: 5 x overall diameter. temperatures below 0 C. PAIR A B PAIR A B NUMBER WIRE WIRE NUMBER WIRE WIRE 1 WHITE/BLUE BLUE/WHITE 16 YELLOW/BLUE BLUE/YELLOW 2 WHITE/ORANGE ORANGE/WHITE 17 YELLOW/ORANGE ORANGE/YELLOW 3 WHITE/GREEN GREEN/WHITE 18 YELLOW/GREEN GREEN/YELLOW 4 WHITE/BROWN BROWN/WHITE 19 YELLOW/BROWN BROWN/YELLOW 5 WHITE/GREY GREY/WHITE 20 YELLOW/GREY GREY/YELLOW 6 RED/BLUE BLUE/RED 21 VIOLET/BLUE BLUE/VIOLET 7 RED/ORANGE ORANGE/RED 22 VIOLET/ORANGE ORANGE/VIOLET 8 RED/GREEN GREEN/RED 23 VIOLET/GREEN GREEN/VIOLET 9 RED/BROWN BROWN/RED 24 VIOLET/BROWN BROWN/VIOLET 10 RED/GREY GREY/RED 25 VIOLET/GREY GREY/VIOLET 11 BLACK/BLUE BLUE/BLACK 26 PINK/BLUE BLUE/PINK 12 BLACK/ORANGE ORANGE/BLACK 27 PINK/ORANGE ORANGE/PINK 13 BLACK/GREEN GREEN/BLACK 28 PINK/GREEN GREEN/PINK 14 BLACK/BROWN BROWN/BLACK 29 PINK/BROWN BROWN/PINK 15 BLACK/GREY GREY/BLACK 30 PINK/GREY GREY/PINK INTERNAL TELEPHONE CABLE TYPE CW1308
101 101 COMMUNICATION CABLES - TELEPHONE ENATS 09-6 Solid tinned annealed copper conductors, PVC insulated, twisted to form pairs, PVC bedding, galvanised steel wire armour, PVC outer sheath. Black. To ENATS 09-6: Issue 5 Section 3.6. Flame propagation to BS4066 PT1 and IEC 332 PT1. CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND CLEAT CODE SIZE (MM 2 ) (MM) PAIRS KG/KM DIAMETER SIZE SIZE (MM) (MM) SINGLE /0.6 ** / / S / / / / / ** 2 pair laid up in quad formation. -20 to +70 C. See colour chart on page 104. temperatures below 0 C. Solid tinned annealed copper conductors, PVC insulated, twisted to form pairs, PVC bedding, galvanised steel wire armour, PVC outer sheath. Black. To ENATS 09-6: Issue 5 Section 3.6. Flame propagation to BS4066 PT1 and IEC 332 PT1. CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND CLEAT CODE SIZE (MM 2 ) (MM) PAIRS KG/KM DIAMETER SIZE SIZE (MM) (MM) SINGLE /0.9 ** S / S / / / / / / / / / / S 1.8 INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES Solid tinned annealed copper conductors, PVC insulated, twisted to form pairs, collective aluminium/mylar foil tape screen complete with 0.5mm 2 drain wire, PVC bedding, galvanised steel wire armour, PVC outer sheath. Black. To ENATS 09-6: Issue 5 Section 3.6. Flame propagation to BS4066 PT1 and IEC 332 PT1. CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND CLEAT CODE SIZE (MM 2 ) (MM) PAIRS KG/KM DIAMETER SIZE SIZE (MM) (MM) SINGLE /0.9 ** / / S / / / / / / / / S 1.8 PVC INSULATED MULTIPAIR ARMOURED CABLE TO ESI STANDARD ** 2 pair laid up in quad formation. -20 to +70 C. 6 x overall diameter. See colour chart on page 104. temperatures below 0 C.
102 102 INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES PVC INSULATED MULTIPAIR ARMOURED CABLE TO ESI STANDARD COMMUNICATION CABLES - TELEPHONE ENATS 09-6 Solid tinned annealed copper conductors, PVC insulated, twisted to form pairs, PVC bedding, galvanised steel wire armour, PVC outer sheath. Black. To ENATS 09-6: Issue 6 Section 4.5. Flame propagation to BS4066 PT1 and IEC 332 PT1. CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND CLEAT CODE SIZE (MM 2 ) (MM) PAIRS KG/KM DIAMETER SIZE SIZE (MM) (MM) SINGLE /0.8 ** S / S / / / / / / / / S 1.8 Solid tinned annealed copper conductors, PVC insulated, twisted to form pairs, collective aluminium/mylar foil tape screen complete with 0.5mm 2 drain wire, PVC bedding, galvanised steel wire armour, PVC outer sheath. Black. To ENATS 09-6: Section 4.5. Flame propagation to BS4066 PT1 and IEC 332 PT1. CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND CLEAT CODE SIZE (MM 2 ) (MM) PAIRS KG/KM DIAMETER SIZE SIZE (MM) (MM) SINGLE /0.8 ** S / S / / / / / / / / S 1.8 Solid tinned annealed copper, polyethylene insulated, low smoke and zero halogen (LSZH) bedding, galvanised steel wire armour, low smoke and zero halogen (LSZH) sheath. Black. Generally to ENATS 09-6: Issue 6 Section 4.5. CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND CLEAT CODE SIZE (MM 2 ) (MM) PAIRS KG/KM DIAMETER SIZE SIZE (MM) (MM) SINGLE /0.8 ** / / S / / / / S 1.8 Solid tinned, annealed copper conductors, polyethylene insulated, twisted to form pairs, collective aluminium/mylar foil tape screen complete with 0.5mm 2 drain, wire, low smoke zero halogen (LSZH) bedding, galvanised steel wire armour, low smoke and zero halogen (LSZH) sheath. Black. Generally to ENATS 09-6: Issue 6 Section 4.5. CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND CLEAT CODE SIZE (MM 2 ) (MM) PAIRS KG/KM DIAMETER SIZE SIZE (MM) (MM) SINGLE /0.8 ** S / S / / **2 pair laid up in quad formation. -20 to +70 C. 8 x overall diameter. See colour chart on page 104. temperatures below 0 C or 40 C.
103 103 PVC AND PE INSULATED ARMOURED CABLES TO ENATS STANDARD UTILITY INDUSTRY PVC CONTROL CABLES, ENATS 09-6 Stranded plain annealed copper conductor,pvc insulated, PVC bedding, galvanised steel wire armour, PVC outer sheath. Black. 600/1000 volts grade to BS6346 / ENATS Flame retardant to IEC c. CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND SIZE SINGLE CODE SIZE (MM) CORES (KG/KM) DIAMETER (MM) CLEAT 6942X2/5ESI 2.5 7/ S X2/5ESI 2.5 7/ S X2/5ESI 2.5 7/ X2/5/ / /12X2/5/ / /19X2/5/ / /27X2/5/ / /37X2/5/ / to +70 C 6 x Overall Diameter White numbered cores. temperatures below 0 C or above 40 C. COMMUNICATION CABLES - TELEPHONE ENATS 09-6 Solid plain annealed copper conductor, polyethylene insulated, polyethylene bedding, galvanised steel wire armour, PVC outer sheath. Black. To ENATS 09-6 issue 6 section 3 table 2 - induced voltage between the pairs up to 15kv. CCC CODE CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND SINGLE SIZE (MM) PAIRS DIAMETER SIZE (MM) CLEAT / / / S 1.8 INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES -20 to +70 C 8 x Overall Diameter 7 pair: centre - red & yellow. outer layer - black & violet, orange & grey**, green & brown, orange & blue**, green & brown, orange & white**. 19 pair: centre - centre and first layer as 7 pair. outer layer - black & violet, odd pairs red & yellow, even pairs green & brown, blue & white. 37 pair: centre, first and second layer as 19 pair. outer layer - black & violet, odd pairs red & yellow, even pairs green & brown, blue & white. **denotes carrier pairs. temperatures below 0 C or above 40 C.
104 104 INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES ENATS 09-6 SECTION 3.6 AND 4.5 CORE IDENTIFICATION CORE IDENTIFICATION ACCORDING TO ENATS 3.6 AND 4.5 SECTION 3.6 COLOUR CODING PAIR A B PAIR A B NUMBER WIRE WIRE NUMBER WIRE WIRE 1 BLACK BLUE 26 WHITE YELLOW 2 BLACK ORANGE 27 WHITE VIOLET 3 BLACK GREEN 28 BLUE RED 4 BLACK BROWN 29 BLUE YELLOW 5 BLACK GREY 30 BLUE VIOLET 6 BLUE WHITE 31 GREEN RED 7 BLUE ORANGE 32 GREEN YELLOW 8 BLUE GREEN 33 GREEN VIOLET 9 BLUE BROWN 34 RED GREY 10 BLUE GREY 35 RED ORANGE 11 ORANGE WHITE 36 RED YELLOW 12 ORANGE GREEN 37 RED BROWN 13 ORANGE BROWN 38 RED VIOLET 14 ORANGE GREY 39 GREY YELLOW 15 GREEN WHITE 40 GREY VIOLET 16 GREEN BROWN 41 ORANGE YELLOW 17 GREEN GREY 42 ORANGE VIOLET 18 BROWN WHITE 43 YELLOW BROWN 19 BROWN GREY 44 YELLOW VIOLET 20 GREY WHITE 45 BROWN VIOLET 21 BLACK WHITE 46 TURQUOISE BLACK 22 BLACK RED 47 TURQUOISE BLUE 23 BLACK YELLOW 48 TURQUOISE RED 24 BLACK VIOLET 49 TURQUOISE ORANGE 25 WHITE RED 50 TURQUOISE YELLOW All two pair cables are in quad formation and colour coded in rotation - Blue, Orange, Green, Brown. SECTION 4.5 COLOUR CODING PAIR A B NUMBER WIRE WIRE 1 WHITE BLUE 2 WHITE ORANGE 3 WHITE GREEN 4 WHITE BROWN 5 WHITE GREY 6 RED BLUE 7 RED ORANGE 8 RED GREEN 9 RED BROWN 10 RED GREY 11 BLACK BLUE 12 BLACK ORANGE 13 BLACK GREEN 14 BLACK BROWN 15 BLACK GREY 16 YELLOW BLUE 17 YELLOW ORANGE 18 YELLOW GREEN 19 YELLOW BROWN 20 YELLOW GREY Each unit is lapped with coloured tape for identification as follows UNIT 1 UNIT 2 UNIT 3 UNIT 4 UNIT 5 UNIT 6 UNIT 7 UNIT 8 UNIT 9 UNIT10 If sub-units are used, binders for corresponding sub-units shall be the same colour. BLUE ORANGE GREEN BROWN GREY WHITE RED BLACK YELLOW VIOLET All two pair cables are in quad formation and colour coded in rotation - White, Red, Blue, Orange. For 30 pair cables the formation will be 3 X 10 pair units numbered - 1, 2 and 3. For 40 pair cables the formation will be 2 X 20 pair units numbered - 1 and 2. For 50 pair cables the formation will be 5 X 10 pair units numbered - 1, 2 3, 4 and 5. For 100 pair cables the formation will be 5 X 20 pair units numbered - 1, 2, 3, 4 and 5.
105 105 PETROLEUM JELLY FILLED TELEMETRY CABLE TO CW1128, CW1128/1198 AND BS3573 COMMUNICATION CABLES PETROLEUM JELLY FILLED Solid plain annealed copper conductors, cellular polyethylene insulated, petroleum jelly filled, PE outer sheath. Black. To CW1128A. Flame propogation to BS4066 PT1 and IEC 332 PT1. CCC STRANDING NO. OF WEIGHT OVERALL GLAND CLEAT CODE (MM) CORES KG/KM DIAMETER SIZE SIZE (MM) / / / / / / / Solid plain annealed copper conductors, cellular polyethylene insulated, petroleum jelly filled solid polyethylene bedding, galvanised steel wire armour, PE outer sheath. Black. To BPO CW 1128A/1198A. (Concentric construction). Flame propagation to BS4066 PT1 and IEC 332 PT1. CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND CLEAT CODE SIZE (MM 2 ) (MM) PAIRS KG/KM DIAMETER SIZE SIZE (MM) (MM) SINGLE / S / S / / / Solid plain annealed copper conductors, cellular polyethylene insulated, petroleum jelly filled, collective aluminium/mylar tape screen, polyethylene bedding, galvanised steel wire armour, PVC outer sheath. Black. To BS3573 and CW1128/1198. Flame propagation to BS4066 PT1 and IEC 332 PT1. INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND CLEAT CODE SIZE (MM 2 ) (MM) PAIRS KG/KM DIAMETER SIZE SIZE (MM) (MM) SINGLE / / / / COLOUR SCHEME FOR BS UNIT CONSTRUCTION PAIR A B NUMBER WIRE WIRE 1 WHITE BLUE 2 WHITE ORANGE 3 WHITE GREEN 4 WHITE BROWN 5 WHITE GREY 6 RED BLUE 7 RED ORANGE 8 RED GREEN 9 RED BROWN 10 RED GREY Cables may be manufactured using 5- pair sub-units coloured as 1-5 and 6-10 UNIT 1 UNIT 2 UNIT 3 UNIT 4 UNIT 5 UNIT 6 UNIT 7 UNIT 8 UNIT 9 UNIT 10 BLUE ORANGE GREEN BROWN GREY WHITE RED BLACK YELLOW VIOLET If sub-units are used binders for corresponding sub-units shall be the same colour.
106 106 INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES DEFENCE STANDARD CONTROL CABLES Tinned annealed flexible copper conductors, PVC insulated, non-hygroscopic binder tape, tinned annealed copper wire braid screen, PVC outer sheath. Black. 440 volts grade. To Ministry of Defence Standard DEF (Part 4 for 7/0.2 conductors, Part 5 for 16/0.2 conductors). Flame propogation to BS4066 PT1 and IEC 332 PT1. CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND CODE SIZE (MM 2 ) (MM 2 ) CORES KG/KM DIAMETER SIZE (MM) (MM) 722C / C / C / C / C / C / C / C / C / C / C / C / C / C / C / C / C /0.20 ** C / C / C / C / C / C / Tinned annealed flexible copper conductors, low smoke and zero halogen (LSZH) insulation, non-hygroscopic binder tape, tinned annealed copper wire braid screen, low smoke and zero halogen (LSZH) outer sheath. Black. 440 volt grade. Generally to ministry of Defence Standard DEF61-12 Part 5 LSF. CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND CODE SIZE (MM 2 ) (MM 2 ) CORES KG/KM DIAMETER SIZE (MM) (MM) LSF1622C / LSF1623C / LSF1624C / LSF1626C / LSF16212C / LSF16218C / LSF16225C / ** Laid up in a pair configuration. -55 to +70 C. 6 x overall diameter. See colour chart on page 107. temperatures below 0 C. DEFENCE STANDARD SCREENED MULTICORE CABLE C TYPE
107 107 DEFENCE STANDARD CONTROL CABLES COLOUR CODING CORE COLOUR NUMBER 1 RED 2 BLUE 3 GREEN 4 YELLOW 5 WHITE 6 BLACK 7 BROWN 8 VIOLET 9 ORANGE 10 PINK 11 TURQUOISE 12 GREY 13 RED/BLUE 14 GREEN/RED 15 YELLOW/RED 16 WHITE/RED 17 RED/BLACK 18 YELLOW/BLUE 19 YELLOW/BLUE 20 WHITE/BLUE 21 BLUE/BLACK 22 ORANGE/BLUE 23 GREEN/BLUE 24 GREY/BLUE 25 YELLOW/GREEN 26 WHITE/GREEN 27 GREEN/BLACK 28 ORANGE/GREEN 29 GREY/GREEN 30 YELLOW/BROWN 31 WHITE/BROWN 32 BROWN/BLACK 33 GREY/BROWN 34 YELLOW/VIOLET 35 VIOLET/BLACK 35 VIOLET/BLACK 36 WHITE/VIOLET INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES Where 2 colours are shown the core is striped e.g. Red/Blue - the core is striped Red with Blue. DEFENCE STANDARD PARTS 4 & 5 CORE IDENTIFICATION
108 108 INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES COMPENSATING AND THERMOCOUPLE CABLES NON-ARMOURED Plain annealed flexible conductors, PVC insulated, laid up to form pairs, collective aluminium mylar foil tape screen, complete with 0.5mm 2 drain wire, PVC outer sheath. Thermocouple wires calibrated to BS4937, ANSI 96.1 and IEC Flame propagation to BS4066 PT1 and IEC 332 PT1. NO OF SIZE STRANDING OVERALL GLAND JX KCB KX TX PAIRS (MM 2 ) (MM) DIAMETER SIZE CCC CCC CCC CCC (MM) (MM) CODE CODE CODE CODE (WAS VX) / / / / / / / to +105 C. 5 x overall diameter. See colour chart on page 93. temperatures below 0 C. ARMOURED Plain annealed flexible conductors, PVC insulated, laid up to form pairs, collective aluminium mylar foil tape screen, complete with 0.5mm 2 drain wire, PVC bedding, galvanised steel wire armour, PVC outer sheath. Thermocouple wires calibrated to BS4937, ANSI 96.1 and IEC Flame propagation to BS4066 PT1 and IEC 332 PT1. NO OF SIZE STRANDING OVERALL GLAND JX KCB KX TX PAIRS (MM 2 ) (MM) DIAMETER SIZE CCC CCC CCC CCC (MM) (MM) CODE CODE CODE CODE (WAS VX) / / / / / / / to +105 C. 6 x overall diameter. See colour chart on page 109. temperatures below 0 C. PVC INSULATED COLLECTIVE SCREENED THERMOCOUPLE EXTENSION AND COMPENSATING CABLE (0.75MM 2 )
109 109 COMPENSATING AND THERMOCOUPLE CABLES COLOUR CODING EX JX KX NX TX UX VX CODE BRITISH BS1843: 1952 AMERICAN ANSI INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES GERMAN DIN RC/SC KCB IEC COLOUR CODING OF THERMOCOUPLE EXTENSION AND COMPENSATING CABLE IEC INTRINSICALLY SAFE
110 110 INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES PVC INSULATED ARMOURED TRAFFIC SIGNAL CABLE, LOOP FEEDER CABLE AND LOOP DETECTOR CABLE TRAFFIC SIGNALLING CABLES TRAFFIC CONTROL CABLE WITH ARMOUR Plain annealed solid copper conductors, PVC insulated, PVC bedding, galvanised steel wire armour, PVC outer sheath, colour orange, generally to BS6346/87 CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND CODE SIZE (MM2) (MM) CORES KG/KM DIAMETER SIZE (MM) (MM) TRAF4X / S TRAF8X / S TRAF12X / TRAF16X / TRAF20X / TRAF4X1/ / S TRAF8X1/ / TRAF12X1/ / TRAF16X1/ / TRAF20X1/ / TRAF8X1ESWA* 1.0 1/ LOOP FEEDER CABLE NON ARMOURED Plain annealed solid copper conductors, PVC insulated, PVC sheathed, colour orange, generally to BS6346/87, 600/1000v grade. CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL BRASS CODE SIZE (MM2) (MM) CORES KG/KM DIAMETER A2 (MM) GLAND TRAF8X1NA 1.0 1/ TRAF12X1NA 1.0 1/ TRAF8X1E* 1.0 1/ to +70 C. 4 core - Red, Blue, Yellow, Green. 8 core - Brown, Yellow, Green, Red, White, Blue, Black, Orange. * includes additional 6mm2 integral earth conductor 12 core - Brown, Yellow, Green, Red, White, Blue, Black, Orange, Red/White, Grey, Red/Blue Violet. 16 core - Brown, Yellow, Green, Red, White, Blue, Black, Orange, Red/White, Grey, Red/Blue, Violet, Brown/Red, Yellow/Red, Grey/Red, Black/Red. 20 core - Brown, Yellow, Green, Red, White, Blue, Black, Orange, Red/White, Grey, Red/Blue, Violet, Brown/Red, Yellow/Red, Grey/Red, Black/Red, Violet/Red, Orange/Red, Green/Red, Blue/White. temperatures below 0 C.
111 111 TRAFFIC SIGNALLING CABLES LOOP FEEDER CABLE NON ARMOURED Plain annealed solid copper conductors, polyethylene insulated, polyethylene outer sheath, colour orange, 600/1000v grade. CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER SIZE (MM) (MM) LOOP2X1/ / (1pr) S LOOP4X1/ / (2pr) S LOOP2X2/ / (1pr) S LOOP4X2/ / (2pr) S -15 to +70 C. 6 x overall diameter. TRAFFIC CONTROL CABLE ARMOURED Plain annealed solid copper conductors, polyethylene insulated, polyethylene bedding, galvanised steel wire armour, polyethylene outer sheath. Generally to BS6346/87. Outer sheath colour: Orange. 600/1000 volts grade. CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER SIZE (MM) (MM) LOOP2X1/5SWA 1.5 1/ (1pr) S LOOP4X1/5SWA 1.5 1/ (2pr) S LOOP2X2/5SWA 2.5 1/ (1pr) S LOOP4X2/5SWA 2.5 1/ (2pr) to +70 C. 6 x overall diameter. 2 core - Brown, Blue 4 core - Brown, Black, Grey, Blue. temperatures below 0 C. 2 core - Brown, Blue 4 core - Brown, Black, Grey, Blue. temperatures below 0 C. INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES LOOP DETECTOR CABLE Tinned flexible copper conductor, ethylene propylene rubber insulated (EPR), polychloroprene sheathed (PCP), 600/100v generally to BS BS6195, sheath colour black. CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER SIZE (MM) (MM) LOOP1/ / S LOOP2/ / S -30 to +85 C. 6 x overall diameter. temperatures below -25 C. PVC INSULATED ARMOURED TRAFFIC SIGNAL CABLE, LOOP FEEDER CABLE AND LOOP DETECTOR CABLE
112
113 113 DATA AND COAXIAL CABLES DATA AND COAXIAL CABLES
114 114 DATA, COAXIAL AND LAN CABLES BELDEN EQUIVALENTS: 8138/SWA/LSF 8 PAIR 28AWG COLLECTIVE SCREEN PLUS STEELWIRE ARMOUR,LSF SHEATH PAIR 16AWG UNSCREENED, PVC SHEATH. 8471/LSF 1 PAIR 16AWG UNSCREENED, PVC SHEATH PAIR 16AWG COLLECTIVE SCREEN, PVC SHEATH. 8719/LSF 1 PAIR 16AWG COLLECTIVE SCREEN, LSF SHEATH. 8723/LSF 2 PAIR 22AWG INDIVIDUAL SCREEN,LSOH SHEATH. 8723/SWA/LSF 2 PAIR 22AWG INDIVIDUAL SCREEN PLUS STEELWIRE ARMOUR, LSF SHEATH PAIR 18AWG COLLECTIVE SCREEN. PVC SHEATH. 8760/LSF 1 PAIR 18AWG COLLECTIVE SCREEN. LSOH SHEATH PAIR 22AWG INDIVIDUAL SCREEN, PVC SHEATH. 8761/LSF 1 PAIR 22AWG INDIVIDUAL SCREEN, LSOH SHEATH PAIR 20AWG COLLECTIVE SCREEN, PVC SHEATH. 8762/LSF 1 PAIR 20AWG COLLECTIVE SCREEN, LSOH SHEATH PAIR 22AWG INDIVIDUAL SCREEN, PVC SHEATH PAIR 22AWG INDIVIDUAL SCREEN, PVC SHEATH PAIR 22AWG COLLECTIVE SCREEN, PVC SHEATH TWIN AXIAL 20AWG, PVC SHEATH. 9463/SWA/PVC TWIN AXIAL 20AWG PLUS STEELWIRE ARMOUR, PVC SHEATH PAIR 24AWG COLLECTIVE SCREEN, PVC SHEATH. 9501/LSF 1 PAIR 24AWG COLLECTIVE SCREEN, LSOH SHEATH PAIR 24AWG COLLECTIVE SCREEN, PVC SHEATH. 9502/LSF 2 PAIR 24AWG COLLECTIVE SCREEN, LSOH SHEATH PAIR 24AWG COLLECTIVE SCREEN, PVC SHEATH. 9503LSF 3 PAIR 24AWG COLLECTIVE SCREEN, LSOH SHEATH PAIR 24AWG COLLECTIVE SCREEN, PVC SHEATH. 9504LSF 4 PAIR 24AWG COLLECTIVE SCREEN, LSOH SHEATH. 9505LSF 5 PAIR 24AWG COLLECTIVE SCREEN, LSOH SHEATH PAIR 24AWG COLLECTIVE SCREEN, PVC SHEATH. 9506LSF 6 PAIR 24AWG COLLECTIVE SCREEN, LSOH SHEATH PAIR 24AWG INDIVIDUAL SCREEN, PVC SHEATH PAIR 18AWG INDIVIDUAL SCREEN, PVC SHEATH. 9841LSF 1 PAIR 24AWG COLLECTIVE SCREEN, LSOH SHEATH. 9842LSF 2 PAIR 24AWG COLLECTIVE SCREEN, LSOH SHEATH. COAXIAL CABLES CT100 CT100LSOH WF100BK WC100BK WF125BR CT125 CT125LSOH CT125BR CT125RBS CT167 CT167RBS RG11AU RG11SWA RG58 RG59BU RG59LSOH RG59SWA RG62AU RG62SWA URM202 URM203 URM70 75 OHM DOUBLE SCREENED, LOW LOSS COAX, AIR SPACED, PVC SHEATH. 75 OHM DOUBLE SCREENED, LOW LOSS COAX, AIR SPACED, LSOH SHEATH. 75 OHM DOUBLE SCREENED, LOW LOSS COAX, FOAM FILLED, PVC SHEATH. 75 OHM DOUBLE SCREENED, LOW LOSS COAX, PE DIELECTRIC, PVC SHEATH. 75 OHM DOUBLE SCREENED, LOW LOSS COAX, FOAM FILLED, PVC SHEATH. 75 OHM DOUBLE SCREENED, LOW LOSS COAX, AIR SPACED, PVC SHEATH. 75 OHM DOUBLE SCREENED, LOW LOSS COAX, AIR SPACED, LSOH SHEATH. 75 OHM DOUBLE SCREENED, LOW LOSS COAX, FOAM FILLED, PVC SHEATH. 75 OHM DOUBLE SCREENED, LOW LOSS COAX, AIR SPACED, DIRECT BURIAL SHEATH. 75 OHM DOUBLE SCREENED, LOW LOSS COAX, FOAM FILLED, PVC SHEATH. 75OHMDOUBLESCREENED, LOWLOSSCOAX, FOAMFILLED, DIRECTBURIALSHEATH. 75 OHM BRAIDED SCREEN, SOLID PE DIELECTRIC, PVC SHEATH. 75OHMBRAIDEDSCREEN,SOLIDPEDIELECTRICPLUSSTEELWIREARMOUR,PVCSHEATH. 50 OHM BRAIDED SCREEN, SOLID PE DIELECTRIC, PVC SHEATH. 75 OHM BRAIDED SCREEN, SOLID PE DIELECTRIC, PVC SHEATH. 75 OHM BRAIDED SCREEN, SOLID PE DIELECTRIC, LSOH SHEATH. 75OHMBRAIDEDSCREEN,SOLIDPEDIELECTRICPLUSSTEELWIREARMOUR,PVCSHEATH. 93 OHM BRAIDED SCREEN, PETUBE ANDTHREAD, PVC SHEATH. 93 OHM BRAIDED SCREEN, PETUBE ANDTHREAD PLUS SWA, PVC SHEATH. 75 OHM BRAIDED SCREEN, CELLULAR PE DIALECTRIC, PVC SHEATH. 75 OHM BRAIDED SCREEN, CELLULAR PE DIALECTRIC, PVC SHEATH. 75 OHM BRAIDED SCREEN, SOLID PE DIELECTRIC, PVC SHEATH. DATA AND COAXIAL CABLES UTP CABLES 4UTPCAT5E ENHANCED UNSCREENED 4 PAIR CAT 5 E, GREY PVC SHEATH. 4UTPCAT5EBU ENHANCED UNSCREENED 4 PAIR CAT 5 E, BLUE PVC SHEATH. 4UTPCAT5ELSF ENHANCED UNSCREENED 4 PAIR CAT 5 E, LSFVIOLET SHEATH. 4FTPCAT5E ENHANCED SCREENED 4 PAIR CAT 5 E, GREY PVC SHEATH. 4FTPCAT5ELSF ENHANCED SCREENED 4 PAIR CAT 5 E, LSFVIOLET SHEATH. 4UTPCAT5EDUCT ENHANCED UNSCREENED 4 PAIR CAT 5 E, DUCT GRADE SHEATH. 4FTPCAT5EDUCT ENHANCED SCREENED 4 PAIR CAT 5 E, DUCT GRADE SHEATH. 4FTPCAT5ESWA ENHANCED SCREENED 4 PAIR CAT 5 E PLUS SWA, LSF BLACK SHEATH. 4UTPCAT6 UNSCREENED 4 PAIR CAT 6, GREY PVC SHEATH. 4UTPCAT6LSF UNSCREENED 4 PAIR CAT 6, LSFVIOLET SHEATH.
115 115 RAILWAY CABLES RAILWAY CABLES
116 116 RAILWAY CABLES RAILWAY CABLES SIGNALING (0.75MM 2-95MM 2 ) RAILWAY SIGNALLING CABLES Stranded or flexible tinned copper conductors to BS6360, EPR insulated to BS for types B1, LSZH insulated for types A1, A2, A3. Heavy duty PCP RS2 sheath for types A1 & B1, LSZH sheath for types A2 & A3. Manufactured to Network Rail specification NR/PS/SIG/00005 (formerly RT/E/PS/00005). CCC RAIL RAIL CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND CODE CODE TYPE SIZE CORES (KG/KM) DIAMETER SIZE (MM 2 ) A11X/75BR 6/ A1 Brown / N/A A11X/75RD 6/ A1 Red / N/A A11X/75OR 6/ A1 Orange / N/A A11X/75GY 6/ A1 Grey / N/A A11X/75VIR 6/ A1 Violet / N/A A11X/75BK 6/ A1 Black / N/A A11X115BK 6/ A1 Black / N/A A21X/75 6/ A / N/A A21X115 6/ A / /16 A32X/75 6/ A / /16 A34X/75 6/ A / S A36X/75 6/ A / S A310X/75 6/ A / A314X/75 6/ A / A336X/75 6/ A / A348X/75 6/ A / B11X2/5 6/ B / /16 B11X10 6/ B1 10 7/ S B11X35 6/ B / B22X1/5 6/ B / S B22X2/5 6/ B / B22X10 6/ B2 10 7/ B22X16 6/ B2 16 7/ B22X35 6/ B / B22X70 6/ B / B22X95 6/ B / B24X/75 6/ B / S B24X1/5 6/ B / B24X2/5 6/ B / B24X10 - B2 10 7/ B27X/75 6/ B / B27X1/5 6/ B / B27X2/5 6/ B / B210X/75 6/ B / B210X1/5 6/ B / B210X2/5 6/ B / B212X/75 6/ B / B26PX/75 6/ B /0.37 6pr B212X1/5 6/ B / B212X2/5 6/ B / B219X/75 6/ B / B219X1/5 6/ B / B219X2/5 6/ B / B227X/75 6/ B / B227X1/5 6/ B / B227X2/5 6/ B / B237X/75 6/ B / B237X1/5 6/ B / B237X2/5 6/ B / B248X/75 6/ B / B248X1/5 6/ B / B248X2/5 6/ B / S -25 to +85 C. 8 x overall diameter. Black with white numbers.
117 117 RAILWAY SIGNALLING CABLES Stranded or flexible tinned copper conductors to BS6360, EPR insulated to BS Heavy duty PCP RS2 sheath for types C1 + C2, LSZH sheath for types D1, D2, E1+E2. Manufactured to Network Rail specification NR/PS/SIG/00005 (formerly RT/E/PS/00005). CCC RAIL RAIL CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND CODE CODE TYPE SIZE CORES (KG/KM) DIAMETER SIZE (MM 2 ) C11X2/5 6/ C / C22X2/5 6/ C / C24X2/5 6/ C / C27X2/5 6/ C / C210X2/5 6/ C / C212X2/5 6/ C / C216X2/5 6/ C / D11X/75 6/ D / /16 D11X1/5 6/ D / /16 D11X2/5 6/ D / /16 D11X10 6/ D1 10 7/ S D11X35 6/ D / D22X1/5 6/ D / S D22X2/5 6/ D / D22X10 6/ D2 10 7/ D22X16 6/ D2 16 7/ D22X35 6/ D / D24X1/5 6/ D / D27X1/5 6/ D / D210X1/5 6/ D / D212X1/5 6/ D / D219X1/5 6/ D / D227X/75 6/ D / D227X1/5 6/ D / D227X2/5 6/ D / D237X/75 6/ D / D237X1/5 6/ D / D237X2/5 6/ D / D248X/75 6/ D / D248X1/5 6/ D / D248X2/5 6/ D / S E11X2/5 6/ E / E22X2/5 6/ E / E24X2/5 6/ E / E27X2/5 6/ E / E210X2/5 6/ E / E212X2/5 6/ E / RAILWAY CABLES -25 to +85 C. 8 x overall diameter. Black with white numbers. RAILWAY CABLES SIGNALING (0.75MM 2-35MM 2 )
118 118 RAILWAY CABLES RAILWAY TRAIN PROTECTION WARNING CABLES Flexible tinned copper conductors to BS6360, EPR insulated to BS , separate drain wire,single aluminium tape screen (polyester backed). Black Heavy duty PCP RS2 sheath to BS7655 for type C3, LSZH sheath for type E3. Manufactured to Network Rail specification NR/PS/SIG/OOOO5 (formerly RT/E/PS/00005). CCC RAIL RAIL CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND CODE CODE TYPE SIZE CORES (KG/KM) DIAMETER SIZE (MM) C3TPWS 6/ C3TPWS /0.25 1PR E3TPWS 6/ E3TPWS /0.25 1PR to +85 C. 8 x overall diameter. RAILWAY CABLES TRAIN PROTECTION WARNING POINT HEATER RAILWAY POINT HEATER CABLES Flexible tinned copper conductor to B6360, EPR insulation type GP4 to BS7655, black PCP type EM2 sheath to BS7655. Manufactured to Network Rail specification NR/SP/ELP/40045 (formerly R/E/PS/40045). CCC RAIL CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND CODE CODE SIZE CORES (KG/KM) DIAMETER SIZE (MM 2 ) 3184PH1/5 6/ / PH1/5 6/ / PH2/ / PH4 6/ / PH / PH / PH / S -30 to +70 C. 4 core - Yellow, Yellow, Blue, Blue. 8 core - Yellow, Yellow, Blue, Blue, Brown, Brown, Black, Black.
119 119 RAILWAY AXLE COUNTING CABLES Solid plain annealed copper conductors, polyethylene insulation, petroleum jelly filled, polyethylene outer sheath. Manufactured to Network Rail specification RT/E/PS/0031. CCC RAIL CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND CODE CODE SIZE PAIRS (KG/KM) DIAMETER SIZE (MM 2 ) F1D0902 6/ / F1D0910 6/ / F1D0912 6/ / F1D0919 6/ / F1D0924 6/ / S F1D1402 6/ / F1D1410 6/ / F1D1412 6/ / S F1D1419 6/ / S F1D1424 6/ / S RAILWAY CABLES RAILWAY CABLES AXLE COUNTING CABLES AND DATALINK PAIR NO A WIRE B WIRE PAIR NO A WIRE B WIRE 1 WHITE BLUE 13 YELLOW GREEN 2 WHITE ORANGE 14 YELLOW BROWN 3 WHITE GREEN 15 YELLOW GREY 4 WHITE BROWN 16 VIOLET BLUE 5 WHITE GREY 17 VIOLET ORANGE 6 RED BLUE 18 VIOLET GREEN 7 RED ORANGE 19 VIOLET BROWN 8 RED GREEN 20 VIOLET GREY 9 RED BROWN 21 TURQUOISE BLUE 10 RED GREY 22 TURQUOISE ORANGE 11 YELLOW BLUE 23 TURQUOISE GREEN 12 YELLOW ORANGE 24 TURQUOISE BROWN Two pair cables laid up in quad formation colour coded in rotation, Orange, White, Green, Black. -40 to +70 C. 15 x overall diameter RAILWAY DATALINK CABLE Solid copper conductor, polythylene insulation, aluminium/polyethylene laminated moisture barrier, polyethylene sheath black or blue. To BR1932. CCC RAIL STRANDING NO. OF WEIGHT OVERALL GLAND CODE CODE CORES (KG/KM) DIAMETER SIZE DATALINK2X1/27 6/ / DATALINK2X1/27BU 6/ / DATALINK2X1/27LSF 6/ / PE sheath -40 to + 70 C LSZH sheath -10 to + 50 C 15 x overall diameter Blue, Red.
120 120 RAILWAY CABLES RAILWAY AXLE COUNTING CABLE NON ARMOURED Solid tinned annealed copper conductors, polyethylene insulation (type 03 to BS6234), petroleum jelly filled (XPS and XQS types only), glass fibre weave, aluminium/polymer laminate tape, polyetheylene sheath XPS type (type 03C to BS6234) or LSZH XPZ type. Manufactured to Network Rail specification RT/E/PS/0031. Spec AzLM axle counter cable NRL2SIG CCC RAIL CABLE CONDUCTOR STANDING NO. OF WEIGHT OVERALL CODE CODE TYPE SIZE (MM) PAIRS (KG/KM) DIAMETER XPS / XPS / XPS / XPS / XPS / XPS / XPS / XPS / XPS / XPS / XPS / XPS 1.5 1/ XPS / XPS 1.5 1/ XPS / XPS 1.5 1/ XPS / XPS 1.5 1/ XPS / XPS 1.5 1/ XPZ / XPZ / XPZ / XPZ / XPZ / XPZ / XPZ / XPZ / XPZ / XPZ / XPZ / XPZ 1.5 1/ XPZ / XPZ 1.5 1/ XPZ / XPZ 1.5 1/ XPZ / XPZ 1.5 1/ XPZ / XPZ 1.5 1/ to + 85 C 7.5 x overall diameter Table 6 core colours: RAILWAY AXLE COUNTING CABLE NON ARMOURED PAIR CORE COLOURS 1 White Blue 2 White Orange 3 White Green 4 White Brown 5 White Grey 6 Red Blue 7 Red Orange 8 Red Green 9 Red Brown 10 Red Grey 11 Yellow Blue 12 Yellow Orange 13 Yellow Green 14 Yellow Brown 15 Yellow Grey 16 Violet Blue 17 Violet Orange 18 Violet Green 19 Violet Brown 20 Violet Grey 21 Turquoise Blue 22 Turquoise Orange 23 Turquoise Green 24 Turquoise Brown Table 7 layer make-up: PAIR NOS. IN EACH LAYER NO. OF PAIRS CENTRE 1ST LAYER 2 1 & & 2 3 -> > 3 4 -> > & 2 3 -> 10
121 121 RAILWAY COPPER TRACKSIDE COMMUNICATION CABLES Solid plain annealed copper conductors to BS6360, polytheylene insulation, petroleum jelly filled, corrugated steel armour, polytheylene outer sheath. Manufactured to Network Rail specification NR/PS/TEL/00015 (formerly RT/E/PS/00015). CCC RAIL CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND CODE CODE SIZE PAIRS (KG/KM) DIAMETER SIZE (MM 2 ) / / / / / / / / / / RAILWAY CABLES -25 to +85 C. 2 PAIR (laid up in quad formation) Bending radius: 10 x overall diameter. PAIR A B NUMBER WIRE WIRE 1 WHITE BLUE 2 WHITE ORANGE 3 WHITE GREEN 4 WHITE BROWN 5 WHITE GREY 6 RED BLUE 7 RED ORANGE 8 RED GREEN 9 RED BROWN 10 RED GREY 20 PAIR (laid up in 4x5 pair) SUB-UNIT (CODE A) PAIR A B NUMBER WIRE WIRE 1 WHITE BLUE 2 WHITE ORANGE 3 WHITE GREEN 4 WHITE BROWN 5 WHITE GREY SUB-UNIT (CODE B) PAIR A B NUMBER WIRE WIRE 1 RED BLUE 2 RED ORANGE 3 RED GREEN 4 RED BROWN 5 RED GREY Each unit is lapped with coloured tape for identification as follows: UNIT UNIT COLOUR OF NUMBER CODE BINDINGS 1 A BLUE 2 B BLUE 3 C ORANGE 4 D ORANGE 30 PAIR (laid up in 3x10 pair) 50 PAIR (laid up in 5x10 pair) Each unit is lapped with coloured tape for identification as follows: COPPER TRACKSIDE CABLE SUB-UNIT (CODE A) PAIR A B NUMBER WIRE WIRE 1 WHITE BLUE 2 WHITE ORANGE 3 WHITE GREEN 4 WHITE BROWN 5 WHITE GREY 6 RED BLUE 7 RED ORANGE 8 RED GREEN 9 RED BROWN 10 RED GREY UNIT COLOUR OF BINDINGS NUMBER 1 BLUE 2 ORANGE 3 GREEN 4 BROWN 5 GREY
122 122 RAILWAY CABLES RAILWAY POWER AND TRACK FEEDER CABLES POWER CABLES Solid plain aluminium sectoral conductors XLPE insulated, PVC outer sheath, Black to BR880 06/ /1000 volts grade to BS CCC RAIL CONDUCTOR NO. OF WEIGHT OVERALL GLAND CODE CODE SIZE CORES (KG/KM) DIAMETER SIZE (MM 2 ) SAC2X16NA 6/ SAC2X25NA 6/ SAC2X35NA 6/ SAC2X50NA 6/ SAC2X70NA 6/ SAC2X95NA 6/ SAC4X70NA 6/ C. 8 x overall diameter. 2 core - Brown, Blue. 4 core - Blue, Brown, Black, Grey. RAILWAY CABLES POWER & TRACK FEEDER TRACK FEEDER CABLES Uncompacted circular stranded aluminium to BS6360 or uncompacted circular stranded tinned copper to BS6360. CSP sheathed type RS4 to BS6899, black. Manufactured to Network Rail specification NR/PS/ELP/21101 (formerly RT/E/S/21101). CCC RAIL POLARITY CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND CODE CODE SIZE CORES (KG/KM) DIAMETER SIZE (MM 2 ) TRACK150 6/ NEGATIVE 150 AL 37/ TRACK161 6/ NEGATIVE 161 CU 91/ TRACK240 6/ NEGATIVE 240 AL 61/ TRACK500 6/ POSITIVE 500 AL 61/ TRACK500CU 6/ NEGATIVE 500 CU 91/ TRACK630CU 6/ POSITIVE 630 CU 127/ S TRACK800 6/ NEGATIVE 800 AL 127/ S TRACK1000 6/ POSITIVE 1000 AL 127/ TRACK240LSF - NEGATIVE 240 AL 61/ TRACK800LSF - NEGATIVE 800 AL 127/ S TRACK1000LSF - POSITIVE 1000 AL 127/ C to +85 C. Aluminium conductor - 10x overall diameter Copper conductor - 8x overall diameter
123 123 MARINE AND OFFSHORE CABLES MARINE AND OFFSHORE CABLES
124 124 MARINE AND OFFSHORE CABLES MARINE AND OFFSHORE CABLES Tinned annealed stranded copper conductors, ethylene propylene rubber (EPR) insulated, low smoke, zero halogen (LSZH) SW4 outer sheath. Black. 600/1000 volts grade to BS6883, IEC , IEC , IEC ,2 and IEC ,2. CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL UKOOA CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER CODE (MM) 6571TQ1/ / WF TQ1/ / WF TQ1/ / WF TQ1/ / WF TQ1/ / WF TQ1/ / TQ1/ / WF TQ1/ / /10TQ1/ / /12TQ1/ / WFA /19TQ1/ / WFB /27TQ1/ / WFC /30TQ1/ / /37TQ1/ / WFD TQ2/ / WF TQ2/ / WF TQ2/ / WF TQ2/ / WF TQ2/ / WF TQ2/ / TQ2/ / WF TQ2/ / /10TQ2/ / /12TQ2/ / WFA /19TQ2/ / WFB /27TQ2/ / WFC /30TQ2/ / /37TQ2/ / WFD TQ / WF TQ / WF TQ / WF TQ / WF TQ / WF TQ / WF TQ / WF TQ / WF TQ / WF TQ / WF406 White with Black numbers. Single cores available in either Black or Green/Yellow outer sheath. temperatures below -15 C. EPR INSULATED NON-ARMOURED SHIPWIRING CABLE (1.5MM 2 TO 6MM 2 )
125 125 MARINE AND OFFSHORE CABLES Tinned annealed stranded copper conductors, ethylene propylene rubber (EPR) insulated, low smoke, zero halogen (LSZH) SW4 outer sheath. Black. 600/1000 volts grade to BS6883, IEC , IEC , IEC ,2 and IEC ,2. CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL UKOOA CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER CODE (MM) 6571TQ / WF TQ / WF TQ / WF TQ / WF TQ / WF TQ / WF TQ / WF TQ / WF TQ / WF TQ / WF TQ / WF TQ / WF TQ / WF TQ / WF TQ / WF TQ / WF TQ / WF TQ / WF TQ / WF TQ / WF TQ / WF TQ / WF TQ / WF TQ / WF TQ / WF TQ / WF TQ / WF10A 6573TQ / WF30A 6571TQ / WF10B 6571TQ / WF10C 6571TQ / WF10D 6571TQ / WF10E 6571TQ / WF10F 6571TQ / WF10G 6571TQ / WF10H MARINE AND OFFSHORE CABLES Single core cables are available in Black or Green/Yellow outer sheath. -30 to +85 C. up to 25mm - 4 x overall diameter. above 25mm - 6 x overall diameter. White with Black numbers. temperatures below -15 C. EPR INSULATED NON-ARMOURED SHIPWIRING CABLE (10MM 2 TO 630MM 2 )
126 126 MARINE AND OFFSHORE CABLES MARINE AND OFFSHORE CABLES Tinned annealed stranded copper conductors, ethylene propylene rubber (EPR) insulated, low smoke, zero halogen (LSZH) bedding, galvanised steel wire braid armour, low smoke, zero halogen (LSZH) SW4 outer sheath. Black. 600/1000 volts grade to BS6883, IEC , IEC , IEC ,2 and IEC ,2. CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL UKOOA CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER CODE (MM) 6582TQ1/ / WB TQ1/ / WB TQ1/ / WB TQ1/ / TQ1/ / TQ1/ / WB /12TQ1/ / WBA /19TQ1/ / WBB /27TQ1/ / WBC /37TQ1/ / WBD TQ2/ / WB TQ2/ / WB TQ2/ / WB TQ2/ / WB TQ2/ / TQ2/ / WB /12TQ2/ / WBA /19TQ2/ / WBB /27TQ2/ / WBC /37TQ2/ / WBD TQ / WB TQ / WB TQ / WB TQ / WB TQ / WB to +85 C. 6 x overall diameter. White with Black numbers. temperatures below -15 C. EPR INSULATED BRAIDED ARMOUR SHIPWIRING CABLE (1.5MM 2 TO 4MM 2 )
127 127 MARINE AND OFFSHORE CABLES Tinned annealed stranded copper conductors, ethylene propylene rubber (EPR) insulated, low smoke, zero halogen (LSZH) bedding, galvanised steel wire braid armour, low smoke, zero halogen (LSZH) outer sheath. Black. 600/1000 volts grade to BS6883, IEC , IEC , IEC ,2 and IEC ,2. CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL UKOOA CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER CODE (MM) 6582TQ6 6 7/ WB TQ6 6 7/ WB TQ6 6 7/ WB TQ / WB TQ / WB TQ / WB TQ / WB TQ / WB TQ / WB TQ / WB TQ / WB TQ / WB TQ / WB TQ / WB TQ / WB TQ / WB TQ / WB TQ / WB TQ / WB TQ / WB TQ / WB TQ / WB TQ / WB TQ / WB TQ / WB20A 6583TQ / WB30A 6584TQ / WB40A 6582TQ / WB20B 6583TQ / WB30B 6584TQ / WB40B 6583TQ / WB30C 6584TQ / WB40C 6583TQ / WB30D 6584TQ / WB40D 6583TQ / WB30E 6584TQ / WB40E MARINE AND OFFSHORE CABLES -30 TO +85 C. 6 x overall diameter White with Black numbers. temperatures below -15 C. EPR INSULATED BRAIDED ARMOURED SHIPWIRING CABLE (6MM 2 TO 300MM 2 )
128 128 MARINE AND OFFSHORE CABLES MARINE AND OFFSHORE CABLES Tinned annealed stranded copper conductors, ethylene propylene rubber (EPR) insulated, low smoke, zero halogen (LSZH) bedding tinned phosphor bronze braid armour, low smoke, zero halogen (LSZH) SW4 outer sheath. Black. 600/1000 volts grade to IEC , IEC , IEC , IEC , IEC ,2 and IEC ,2. CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL UKOOA CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER CODE (MM) 6591TQ6 6 7/ WAB TQ / WAB TQ / WAB TQ / WAB TQ / WAB TQ / WAB TQ / WAB TQ / WAB TQ / WABOA 6591TQ / WABOB 6591TQ / WABOC 6591TQ / WABOD 6591TQ / WABOE 6591TQ / WABOF 6591TQ / WABOG 6591TQ / WABOH -30 to +85 C. 6 x overall diameter. White. temperatures below -15 C. EPR INSULATED SINGLE CORE BRAIDED SHIPWIRING CABLE (6MM 2 TO 630MM 2 )
129 129 INSTALLATION ACCESSORIES INSTALLATION ACCESSORIES
130
131 131 LML LML Products Limited Since its inception in 1968, LML has designed, manufactured and supplied a comprehensive range of copper tube terminals including bespoke specials. With in-house tooling and electroplating facilities, LML will always provide a solution for its quality focused customers in compliance with BS EN ISO 9001:2000 Copper Tube Terminals LML terminals are manufactured from seamless copper tube to BS EN and feature bell mouth entry up to 400mm 2 and chamfered entry from 500mm 2 to 1000mm 2. All terminals and splices (other than parallel splices) are provided with an inspection hole to ensure the conductor is fully inserted before crimping. Internal barrel diameters suit standard cables as defined in BS EN Standard finish is bright electro tin plating to BS EN Other finishes can be provided, e.g. nickel or silver. Terminals are independently tested to comply with BS EN , and are also approved for military use and by London Underground. Crimp Tooling LML Products also supply a large range of manual hydraulic tools for crimping terminals from 1.5mm 2 to 1000mm 2. LML also supplies a range of hydraulic crimping tools with rechargeable battery. Med/High Voltage Crimp Terminals LML Products manufactures a range of copper tube terminals to suit 11kv and 33kv. We also manufacture water blocked splices and terminals.
132
133
134 www. cmp-products.com CMP CMP PRODUCTS SERVICES AND SUPPORT FROM CMP PRODUCTS CMP Products offers a comprehensive training program for the installation of it's products. Whether you just need a video to show you how it's done, require practicaldemonstrations at your premises or indeed you require training on site for large groups, CMP is able to assist. We offer certified training on all of our products with all attendees receiving a training certificate following successfulcompletion of the course to demonstrate competence. CERTIFIED TRAINING AVAILABLE for designers/specifiers for installers for a QA, QC Personnel installation video's available for all products in multiple languages for design engineers to assist with correct product selection to keep up with the latest standards wherever you need it, when you need it ALSO AVAILABLE from CMP Products Breather Drain Plugs Adaptors & Reducers Stopper Plugs Unions Locknuts Serrated Washers Earth Tags Entry Thread Seals Shrouds
135 135 RAXTON LIMITED Raxton products are designed to solve the fundamental difficulties which exist due to the variety of thread forms currently in use within the electrical industry. These thread forms are predominantly Isometric, Imperial, N.P.T., BSP and PG. Problems caused by dissimilar threads can occur in many environments including industrial, EExd, EExe and mining. Raxton conversions are fully approved to meet these requirements, being certified by leading test authorities including BASEEFA, SIRA, ISSEP, KEMA, DET NORSKE VERITAS and Standards Association of Australia. They are marked accordingly. Standard material is brass and readily available alternatives include mild steel, stainless steel and aluminium. Our EExe range is also available in glass filled nylon. ADAPTORS REDUCERS HEXAGON HEAD PLUGS RIGHT ANGLE ADAPTORS MALE TO MALE ADAPTORS UNIONS STOPPING PLUGS EARTH LEAD ADAPTORS THREADED EARTH PLATES NYLON GLANDS SCREWED NIPPLING COUPLERS BUSHES SHROUDS LOCKNUTS/LOCKRINGS EARTH TAGS WASHERS
136 Legrand cable management solutions... LEGRAND CABLE MANAGEMENT
137
138 138 W. J. FURSE & COMPANY LIMITED E-Klips is a division of W J Furse & Co Ltd, a multi-disciplined engineering and marketing company employing nearly 200 people worldwide. We are the largest UK manufacturer of a comprehensive range of industrial fasteners, which are made available to the electrical/mechanical industry. They provide a quick, efficient method of fixing without drilling or bracket making. Our commitment to quality has set industry standards while our new designs bring you all the benefits of E-Klips continuous product development philosophy. Wholly manufactured in the UK, E-Klips fasteners can be found throughout Europe and in many other countries in the world where our unequalled combination of speed and quality is properly appreciated. This combination can give you savings of up to 60% over a complete installation a very significant competitive advantage! E-Klips are available for every type of installation through our established distributor network who are fully supported by our stocks and service. So, if you would like to use the faster fastener, simply specify E-Klips and put your opposition in the shade.
139 139 W. J. FURSE & COMPANY LIMITED As a recognised world leader in the Earthing and Lightning Protection Industry, W J Furse has a proven track record spanning over one hundred years. The range complies with the requirements of relevant British and World standards, and our design and manufacturing quality control systems are independently assessed and approved to ISO9001. W J Furse can also offer a level of competitiveness, service and technical support that is the envy of competitors both in the UK and overseas. Our extensive range includes the following: Earth Rods Copperbond, solid copper and stainless steel. Earth Pits Lightweight, high performance plastic and regular duty concrete pits. Fittings Clamps, bonds, clips and accessories in copper and aluminium alloys and plastics suitable for flat tape and solid circular conductor systems. Conductors An extensive range of copper and aluminium conductors available bare and PVC covered. Specialist Products Including weldable and adhesive conductor clips and earth rod seals. Furseweld Process An exothermic welding process with a simple self contained method of forming high quality electrical connections which do not require external power or heat source, making the process completely portable.
140 140 FRAMING AND SUPPORT SYSTEMS AVAILABLE IN HOT DIP GALVANISED OR STAINLESS STEEL
141 141 AVAILABLE IN HOT DIP GALVANISED OR STAINLESS STEEL *These items require a separate M10X40 cone bolt
142
143 Tel: Fax: Cables & leads Cable management Heating & ventilation Distribution, switchgear & enclosures Lamps Lighting products Security & emergency Site equipment. tools & fixings Wiring accessories MEMBER offering a great deal more
144 Middlesbrough Branch Riverside Park Road, Middlesbrough, Cleveland TS2 1QW Tel: Sales / Admin Fax: Sales / Admin [email protected] Website: Milton Keynes Branch 7 Fitzhamon Court, Wolverton Mill South, Milton Keynes MK12 6LB Tel: Fax: [email protected] Warrington Branch 2 Bishops Court, Calver Road, Winwick Quay, Warrington WA2 8QY Tel: Fax: [email protected] Bristol Branch St. Georges Industrial Estate, St. Andrews Road, Avonmouth, Bristol BS11 9HS Tel: Fax: [email protected] London Branch Crabtree Manorway South, Belvedere, Kent DA17 6AB Tel: Fax: [email protected] Bilcourt Electrical Distributors Ltd Riverside Park Road, Middlesbrough, Cleveland TS2 1QW Tel: Fax: [email protected] Glasgow Branch 56 Clydesmill Road, Cambuslang Investment Park, Cambuslang, Glasgow G32 8RE Tel: Fax: [email protected] Newcastle Branch Fisher Street Industrial Estate, Walker, Newcastle Upon Tyne NE6 4LT Tel: Fax: [email protected] Aberdeen Office Westhill Business Centre, Arnhall Business Park, Westhill, Aberdeen AB32 6UF Tel: Sales Fax: Sales
Corporate Profile ROYAL. MODERN ROYAL ELECTRIC Ideal Power Solution MRE ELECTRICAL, INSTRUMENTATION & COMMUNICATION SYSTEMS
Corporate Profile MODERN ROYAL ELECTRIC Ideal Power Solution ROYAL MRE ELECTRICAL, INSTRUMENTATION & COMMUNICATION SYSTEMS MAJOR STOCKIST >>> CATHODIC PROTECTION CABLES >>> LOW VOLTAGE CABLES >>> MEDIUM
Important Information: Complete Terms and Conditions are printed on sales invoices
Important Information: Complete Terms and Conditions are printed on sales invoices Notice: L&H Group is continually working to improve and add new products to the Cable Express product range. For this
Fire Resistant Cables
109/4 Fire Resistant Cables SR 114H Standard - SR 114E Enhanced BS 5839-1 BS 7629-1 BS 6387 BS 8434-1/2 BS 6425 BS 7622 EN 50200 World-wide recognized high quality cables Firecel SR114 are used in: Data
The Quality Connection. BETAflam Fire Resistant Safety Cables
The Quality Connection BETAflam Fire Resistant Safety Cables 2 Contact Consulting and sales Switzerland Phone +41 (0)62 288 82 82 Fax +41 (0)62 288 83 83 [email protected] www.leoni-infrastructure-datacom.com
FIRE RESISTANT CABLE CONSTRUCTION OF CABLES
FIRE RESISTANT CABLE In all fire disasters, fire smoke, heat and toxic fumes are the main obstacles to safe evacuation of a building or area. A major contribution towards overcoming these hazards is the
Power and Wiring Cables
1 Single-Core PVC 1X...................... 1: Single-Core PVC/PVC 1Y.................. 1: Flat Twin & Flat Three Core PVC /Y........ 1: Multicore XLPE/LSF/SWA/LSF BS Control Cable.............................
ScottishPower Distribution Cables & Equipment. Metal Theft
ScottishPower Distribution Cables & Equipment Metal Theft April 2012 As an aid to deterring to metal theft this booklet has been put together to help identify the types of utility power cables and associated
VIPERFLEX ELECTRIC CABLE
VIPERFLEX Flexible Low Voltage Electric Cable - 0.6/1kV (Rubber insulated) H07 RN-F & H07 BN-F Single Core 2-Core 2-Core and Earth 3-Core and Earth 4-Core and Earth Multi-Core and Earth H07 RCN-F & H07
FIRE RESISTANT CABLES FP200 GOLD
FIRE RESISTANT CABLES FP200 GOLD FIRE RESISTANT CABLES FP200 GOLD BS7629-1:2008 Certificate No 077f Certificate No 077k FP200 GOLD The original highly durable and dressable, easy to terminate and install
CONFLEX ELECTRIC CABLE
CONFLEX ELECTRIC CABLE CONFLEX - 0.6/1kV Flexible VSD/EMC Cables Applications WW VSD/EMC cables are manufactured for use where electrical interference distorts signal transmission in electric motors. Standard
AFUMEX LSX LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 BASEC APPROVED PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:
PRODUCT DATASHEET & APPLICATIONS GUIDE BASEC APPROVED AFUMEX LSX LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 KEY BENEFITS: BASEC approved for the full size range of BS8436 (1.0mm 2 to 2.5mm 2
<< Previous Page Next Page >>
> CONTENTS INTRODUCTION 01 INDUSTRIAL CABLE GLANDS 03-09 COMPRESSION TERMINALS 10-22 CABLE CLEATING & FIXING SYSTEMS 23-33 STANDARD SELECTOR CHARTS 34-37
Airdac CNE and SNE, 600/1000V, Polyethylene Sheath, SANS 1507, NRS 063 & NRS 017
Airdac CNE and SNE, 600/1000V, Polyethylene Sheath, SANS 1507, NRS 063 & NRS 017 Conductor: Hard Drawn Copper Conductor Class 2 Insulation: LV-XLPE Phase Color Code(SNE): Red, Black & Bare Copper Phase
Cables, Cable Laying & Accessories Manual
Distribution Business Cables, Cable Laying & Accessories Manual Database ref: File Ref: Title Page & Revision Log For Cables & Access v4 - Nov 2003.doc Manual Name: Cables & Accessories Manual Version
www.ptranscable.com We specialize in low voltage cables including: Stranded Single Cable H07V-R Flexible Single Cable H05V-K
P-trans, meaning power transistor, is a well known cable manufacturer based in Aan - Jordan. The production plant produces all sorts of high quality low tension cables and is a leader in the industry supplying
Standard Buccaneer - Ethernet
IP6 rated compliant PUR jacket on cable Shielded system shielded coupler Shroud on RJ45 Screw coupling Rewireable flex connector PCB mounted panel connector IDC termination panel connector Earth lead version
Gulf Cable & Electrical Ind. Co.
CONTENTS INTRODUCTION PRODUCT RANGE I PRODUCT DATA TABLES Irrigation 1 Coaxial s for T.V/ Satellite Antenna etc 2 Data Transmission s - 4 pair 24 AWG 3 TELEPHONE CABLES Telephone cables CCP-LAP & CCP-LAP-SS
International Electrotechnical Commission Standards
International Electrotechnical Commission Standards Standard IEC 60028 IEC 60038 IEC 60050-461 IEC 60055-1 IEC 60055-2 IEC 60092-101 IEC 60092-350 IEC 60092-351 IEC 60092-352 IEC 60092-353 IEC 60092-354
Gulf Cable & Electrical Ind. Co.
CONTENTS INTRODUCTION PRODUCT RANGE I PRODUCT DATA TABLES XLPE INSULATED 600/1000V CABLES Two Core Cables CU/XLPE/PVC/LC/PVC/SWA/PVC 1 Three Core Cables CU/XLPE/PVC/LC/PVC/SWA/PVC 2 Four Core Cables CU/XLPE/PVC/LC/PVC/SWA/PVC
PROFIBUS cable. PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications
Data Sheet 10/63-6.47-EN Rev. D PROFIBUS cable PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications PROFIBUS PA cables Non-Ex (Hazardous) applications Ex (Hazardous) applications
Global cable expertise for rolling stock
Global cable expertise for rolling stock Global cable expertise for rolling stock Single and multicore Low voltage control cables Jumper cables HV roof cables (25 kv) rubber cables for power needs of locomotives
INTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 60502-1 Second edition 2004-04 Power cables with extruded insulation and their accessories for rated voltages from 1 kv (U m = 1,2 kv) up to 30 kv (U m = 36 kv) Part 1: Cables
Network Standard Advice No. 1420C 9/6/2011
Network Standard Advice No. 1420C 9/6/2011 TO: Customers, Service Providers and Ausgrid Staff. Advisory Note on Changes to the Use of 11kV Cable Types. Introduction This Network Standard Advice (NSA) provides
3.6/6 kv XLPE insulated cables 5. 6/10 kv XLPE insulated cables 15. 8.7/15 kv XLPE insulated cables 25. 12/20 kv XLPE insulated cables 35
CONTENTS INTRODUCTION 1 Cable selection, cable specification, cable services CABLES Constructional data: 3.6/6 kv XLPE insulated cables 5 SECTION 1 6/10 kv XLPE insulated cables 15 SECTION 2 8.7/15 kv
CABLES FOR PHOTOVOLTAIC SOLAR ENERGY INSTALLATIONS FOR CLEAN ENERGY
CABLES FOR PHOTOVOLTAIC SOLAR ENERGY INSTALLATIONS FOR CLEAN ENERGY One Company Connecting The World POWERFUL PRESENCE PRODUCTS PERFORMANCE PEOPLE General Cable has been a wire and cable innovator for
Contents. All Rights Reserved
Electricity Specification 400C8 Issue 6 October 2015 LV Service Cables Contents 1 Scope 2 Definitions 3 General Requirements for Approvals and Assurance 4 Conditions of Installation 5 Conditions of Operation
Specializing in the cable business for over 38 years, PT. SUPREME CABLE
Specializing in the cable business for over 38 years, PT. SUPREME CABLE MANUFACTURING & COMMERCE Tbk. (PT. SUCACO Tbk) has grown steadly to become a largest and leading cable manufacturer, with international
Flygt flexible cables
Flygt flexible cables Contents Standards General SUBCAB 4 Screened SUBCAB 6 Rubber cable type: NSSHÖU-J 7 Screened rubber cable type: NSSHÖU../E + ST 8 FGB screened rubber cable 9 PUR control cable 0 HCR
ISO 9001 ISO 14001 CABLES AND WIRES CATALOGUE 2008
ISO 9001 ISO 14001 CABLES AND WIRES CATALOGUE 2008 INTRODUCTION... 4 CHAPTER I SINGLE CORE NON-SHEATHED CABLES H05V-U, H05V-R, H05V-K... 6 H05V2-U, H05V2-R, H05V2-K... 7 H07V-U, H07V-R, H07V-K... 8 H07V2-U,
6000 Series Buccaneer
Robust, instant connections for harsh environments 6000 Series Buccaneer - circular connectors that combine the ease of use of a push/pull coupling mechanism with proven environmental sealing. Available
Flexible cables for submersible products
Flexible cables for submersible products Standards SUBCAB cables complies with the following general standards: IEC 6045 (general) IEC 608 class 5 (conductor) IEC 608-- CLAUSE 9 (oil resistant) IEC 608--
MEDIUM VOLTAGE CABLES Up to and including 36 KV
MEDIUM VOLTAGE CABLES Up to and including 6 KV NOTICE As this catalogue is not intendedto cover all of LIBAN CABLES SAL possibilities in special cables manufacturing, the hereafter listing of the types
CURRENT RATINGS MORE THAN A CABLE
CURRENT RTINGS Updated for the 17th Edition of the IEE Wiring Regulations MORE THN CBLE C O M P N Y EI CBLES, DURHM ROD, BIRTLEY, CO DURHM. DH3 2R Tel: +44 (0)191 410 3111 Fax: +44 (0)191 410 8312 E-mail:
British Standards BSEN 3475-513:2005
s British Standard BS 91:1998 BS 215:1970 BS 638-4:1996 BS 1990-1:1984 BSEN 3475-100:2002 BSEN 3475-201:2002 BSEN 3475-301:2002 BSEN 3475-302:2002 BSEN 3475-303:2002 BSEN 3475-305:2002 BSEN 3475-306:2005
EARTHING AND BONDING AT SECONDARY SUBSTATIONS
DISTRIBUTION CONSTRUCTION MANUAL SECTION 4 - SUBSTATIONS ISSUE B SEPT 1996 4.4.4 EARTHING AND BONDING AT SECONDARY SUBSTATIONS 1 SCOPE This section of the Distribution Construction Manual lays down the
Festoon 715 P PUR cable for flexible application in festoon systems
CABLES FOR CRANE AND CONVEYOR APPLICATIONS Festoon 715 P PUR cable for flexible application in festoon systems S AB BRÖCKSKES D-VIERSEN Festoon 715 P 1 x 16.0 mm 2 C Marking for Festoon 715 P 07150162:
Amphenol Cable Glands and Cord Grips 12-055-1. Amphenol
Amphenol Cable Glands and Cord Grips 12-055-1 Amphenol Table of Contents Page Number Introduction 1 Amphenol Cable Glands 2-3 ATEX Approved Glands Featuring Elastometric Seals EX-20 4-5 EX-25 6-7 EE-30
LEAD FREE FIREX. Interlock Armored Cables TECK90 and MC Industrial Cables. w w w. n e x a n s e n e r g y. c o m
FIREX Interlock Armored Cables TECK90 and MC Industrial Cables LEAD FREE O V E R 1 8 0 Y E A R S O F E X P E R I E N C E 866-663-9267 w w w. n e x a n s e n e r g y. c o m Interlock Armored Cables Introduction....2
APPLICATION ORIENTED DESIGN OF CABLES
APPLICATION ORIENTED DESIGN OF CABLES Mrs. Rohini Bhattacharyya, Dubai cables Ltd.P. O. Box 11529,Dubai. [email protected] Mr. Nawaf Ahmad Al Mohaideb Dubai Cables Ltd. P. O. Box 11529, Dubai. [email protected]
PROFIBUS cable. for PROFIBUS-PA and -DP 10/63-6.46 EN
for PROFIBUS-PA and -DP 10/63-6.46 EN CPN 080/CPE 080-Ex PROFIBUS-PA basis cable AWG 18, 0.88 mm 2 Use For fixed installation indoor and outdoor, on racks and in conduits. Application Fieldbus cable for
Offshore Transformer Platform. Technical Standard. Energinet.dk. HV, MV, LV and Signal Cables and Cable Routing
Offshore Transformer Platform Technical Standard Energinet.dk HV, MV, LV and Signal Cables and Cable Routing ETS - 03 Rev. 1 Acadre doc. 44858-09 Revision survey Chpt. Description Revision Date Resp. -
Building Cables and Wires
Building Cables and Wires 4 Introduction alfanar is equipped with state-of-the-art manufacturing facilities such as latest machineries, instrumentation, quality control and testing laboratory, etc., for
BETAtrans. Cables and Systems for Rolling Stock. Edition 2006
BETAtrans Cables and Systems for Rolling Stock. Edition 2006 Info Consulting and Sales By Phone To ask for Information or to place an order please use the following number: +49 (0)9172-6844-11 By Fax For
Instrumentation Cable...14-17. Power Cable...2-11. Assembly Solutions...32
Severe Cold Durability Exceeds CSA Cold Bend / Cold Impact (-0 C/-35 C) Drilling Mud Resistant Flame Retardant Certified to IEC 9-3 (33-3A) and IEEE 580 Oil Resistant Assemblies...3-33 Ester Based Mud
Pressure monitoring equipment for oil-sf 6. bushings, type GOEK
Pressure monitoring equipment for oil-sf 6 bushings, type GOEK Installation and maintenance guide 5693 827-6 en, Rev. 3, 2002-01-30 This document must not be copied without our written permission, and
RADOX railway cables acc. to EN 50264 and EN 50306. Edition 2009
RADO railway cables acc. to EN 50264 and EN 50306 Edition 2009 Bridging our know how Interdisciplinary knowledge The HUBER+SUHNER Group is a leading international manufacturer of electrical and optical
Unarmored Variable Frequency Drive (VFD) Cable Termination Guide
Authorized Distributor Unarmored Variable Frequency Drive (VFD) Cable Termination Guide Be Certain with Belden A Step-by-Step Look at the Connection/Termination of Unarmored VFD Cables Terminating Unarmored
CAVEL VS80205 MADE IN ITALY 1000 V
0,05 9,00 x 7,20 (Pet) (LSZH) Attached CE01 CE02 Sheath Colour black black red Non-migrating Polyester tape longitudinally overlapped (Pet) 25 x 23 µm Outer sheath of Thermoplastic material - black - halogen-free,
The Handbook 2013 EDITION
The Handbook 2013 EDITION Trust Als you safe Alsecure is the cable you can stake your reputation on when safety and security are critical to maintain circuit integrity for mains power, lighting, alarms,
MEDIUM VOLTAGE POWER CABLES
MEDIUM VOLTAGE POWER CABLES CONTENTS 1 GENERAL INTRODUCTION 4 TECHNICAL INFORMATION 15 25 35 45 Single Core XLPE Insulated PVC Sheathed Cables UNARMOURED CABLES COPPER UNARMOURED CABLES ALUMINUM ALUMINUM
Gexol. Gexol. The Global Cable Solutions Company. Designed for safe, reliable performance in the harshest oil and gas operating environments
Gexol Gexol World Class World Class Designed for safe, reliable performance in the harshest oil and gas operating environments Power Control Instrument VFD The Global Cable Solutions Company Gexol World
e-mobility Special cables for electric vehicles Coroplast Fritz Müller GmbH & Co. KG Tapes Cables Cable Assemblies
www.echtzeit.com e-mobility Coroplast Fritz Müller GmbH & Co. KG Tapes Cables Cable Assemblies Special cables for electric vehicles Wittener Straße 271 D-42279 Wuppertal Phone +49(0)202.2681.228 Fax +49(0)202.2681.360
Flexible and safe solutions, for decades. Cables for alarmand safety systems
Flexible and safe solutions, for decades. Cables for alarmand safety systems 2 We offer the widest range of cables on the market for every kind of installation. It s all about reliability. It is always
CMP PRODUCTS CMP. Terminating Cables is our Business. Onshore Offshore Marine Mining Surface Underground
PRODUCTS Industrial and Explosive Atmosphere s and Conduit Accessories Terminating s is our Business Onshore Offshore Marine Mining Surface Underground Solutions complying with BS 6121, EN 50262, IEC 62444,
100% EMI Emission Containment
100% EMI Emission Containment Designed for Longer Service Life Highly Flexible for Easier Handling and Faster Installation Authorized Distributor Industrial VFD Cables Index n Variable Frequency Drive
Marine & Shipboard Cable JIS C 3410(1999) IEC 60092-350, 353, 354, 376
T o t a l S o l u t i o n o f M a r i n e C a b l e Marine & Shipboard Cable JIS C 3410(1999) IEC 60092-350, 353, 354, 376 Marine & Shipboard cable Total Solution of Marine Cable JIS C 3410(1999), IEC
Session 14 Cable Support Systems
Session 14 Cable Support Systems Cable Support Systems in the IEC World A new IEC Standard, IEC61537 2001 has been developed If full details of the cabling layout are available then the likely cable load
Fault location on power cables. Fault location on power cables
Fault location on power cables Fault location on power cables Contents: 1. Introduction 2. Construction of power cables 3. Cable faults 01. Introduction Fault location on communication and power cables
Flexible Cables and Cords
PVC Types Tri-Rated Single-Core....................... : H0V-K (1X) & H0V-K (01X) Single-Core... : DEF 1-1 Equipment Wires.................. : PVC Insulated and Sheathed Flexible Multicore (1*Y).........................
108-93018 05 APR 2016 Rev M
Product Specification 108-93018 05 APR 2016 Rev M Copper LAN Cable 1. SCOPE 1.1. Content This specification describes the general requirements for CommScope copper LAN cable. 2. APPLICABLE DOCUMENTS The
Tri-Rated Flexible PVC Equipment Wire
Application: High temperature, flame retardant wire designed for use in the switch control, relay and instrumentation panels of power switchgear and for purposes such as internal connectors in rectifier
with coloured cores and overall copper screen UL/CSA... 17
CONTENT Cable Track Cables y SD 200 extremely flexible TPE/PUR data cable with coloured cores for continuous movement..... 6 y S 200 extremely flexible TPE/PUR control cable with numbered cores for continuous
I N D U S T R I A L C A B L E G L A N D S
Introduction 1/2 Industrial Cable Gland W Industrial Cable Gland WL Heavy Duty Industrial Cable Gland CW Industrial Cable Gland CZ Industrial Cable Gland 1W Industrial Cable Gland 1Z Industrial Cable Gland
CABLE GLANDS AND CONNECTORS FOR THE IEC & NEC WORLD ATEX 95 & BEYOND ATEX 95 CMP PRODUCTS. Triple Certified
IECEx & ATEX 95 CMP PRODUCTS S AND CONNECTORS FOR THE IEC & NEC WORLD ATEX 95 & BEYOND Triple Certified Single Solution Three Forms of Protection Ex d / Ex e / Ex nr N O O T H E R M A CONTENTS Leading
DOMESTIC ELECTRICAL INSTALLATION CERTIFICATE (Requirements for Electrical Installations BS 7671 IEE Wiring Regulations)
DOMESTIC ELECTRICAL INSTALLATION CERTIFICATE (Requirements for Electrical Installations BS 7671 IEE Wiring Regulations) DETAILS OF THE CLEINT Client and address ADDRESS OF THE INSTALLATION Installation
Mini USB and USB 2.0-IP67 Connector System
Mini USB and USB 2.0-IP67 Connector System Section 12 Mini USB and USB 2.0-IP67 Connector System CONEC has added the Mini-USB connector. This Mini-USB IP67 receptacle and plug family, feature a bayonet
4 IX D N E P P A Installation methods Current-carrying capacity and voltage drop for cables Reference method IET Wiring Matters
8 Appendix 4 of BS 7671 by Mark Coles Appendix 4, Current-carrying capacity and voltage drop for cables and flexible cords, has seen significant changes with the publishing of BS 7671:2008. This article
Operating Instructions
Operating Instructions Cable Glands Ex d and Ex e with Compound > Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Safety Information...3 4 Designated Use...4 5 Technical Data...4
HINDUSTAN PETROLEUM CORPORATION LIMITED ENGINEERING & PROJECTS GRESHAM ASSURANCE HOUSE, 2 ND FLOOR, A-1595(3) 1-A, SIR P M ROAD, FORT MUMBAI-400 001
NEW POL DEPOT AT HINDUSTAN PETROLEUM CORPORATION LIMITED ENGINEERING & S GRESHAM ASSURANCE HOUSE, 2 ND FLOOR, A-1595(3) 1-A, SIR P M ROAD, FORT MUMBAI-400 001 TECHNICAL SPECIFICATION OF XLPE, FRLS LT CABLES
FOREWORD ONE OF THE WORLD S BIGGEST COMPANIES IN THE SECTOR.
OFFSHORE CABLES FOREWORD ONE OF THE WORLD S BIGGEST COMPANIES IN THE SECTOR. General Cable Corporation is one of the world s leading cable manufacturing companies. In its work it has contributed decisively
CMP PRODUCTS. Ex d / Ex e / Ex nr CABLE GLANDS AND CONNECTORS. Triple Certified. www.cmp-products.com www.cmp-products.ru
www.cmp-products.com www.cmp-products.ru IECEx & ATEX 95 CMP PRODUCTS CABLE GLANDS AND CONNECTORS FOR THE IEC & NEC WORLD ATEX 95 & BEYOND C US Triple Certified Single Solution - Three Forms of Protection
UGVCL/SP/591/11KV HT AB CABLE
TECHNICAL SPECIFICATION FOR 11KV AERIAL BUNCHED CABLES FOR OVERHEAD LINES (CROSSED LINKED POLYTHENE DRY GAS CURED) 1. SCOPE This specification covers requirements of XLPE insulated, 11 KV Aerial Bunched
LT/HT Power & Control Cables
LT/HT Power & Control s Catalogue 2014 HT Power s upto 66kV 1.1 kv Power s 1.1 kv Copper Control s ISO-9001/ 14001/18001 Certified Certification Building customer confidence by providing a wide range of
Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, 2016. Underground branch circuit feeding a detached garage:
Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, 2016 * Garage construction requires permits (electrical, building) * Permits must be applied for at the time. * Dial
Screened cable and data cable segregation
December 2007 Screened cable and data cable segregation Can an armoured power cable be considered a screened cable and how does this relate to power and data cable segregation? The short answer is yes;
Technical cable guide
Technical cable guide November 2014 One stop-shop for all your cable needs Welcome to the latest edition of the Technical Cable Guide. Following the recent acquisition of Draka, the Prysmian Group is now
Communication, Signal & Data Cables
Communication, Signal & Data Cables Used for indoor installation and interconnection of transmission, telephone, telegraph and electronic equipment as well as media equipments www.alfanar.com Communication
GUIDE TO THE AM2 EXAM
AM2 GUIDE TO THE AM2 EXAM What is AM2? AM2 or the Achievement Measurement 2 is a practical performance skill test administered by the National Electrotechnical Training (NET). You must take the AM2 test
The Instrumentation Cable Experts
1 The Instrumentation Cable Experts Facilities Head office & factory 1300 Industrial Boulevard Mt Pleasant, Texas 75455, USA www.dekoroncable.com Stocking Centres USA Mt Pleasant and Houston Singapore
5.2. Overview. The better method to install solderless compression connectors on power cable
5.2 Overview The better method to install solderless compression connectors on power cable The Thomas & Betts method of installing compression connectors on power cables is designed to provide a high degree
Copper Cables CONNECTIVITY & CABLING SYSTEM
Copper Cables CONNECTIVITY & CABLING SYSTEM Category 5E M0502057-91 EN CPR 6707 U/UTP tested up to 200 MHz U/UTP CAT5E, unshielded 4-pair cable (100 Ohm), with PVC or LSZH (Low Smoke Zero Halogen) outer
Industrial Cable Solutions for Variable Frequency Drives
Industrial Cable Solutions for Variable Frequency Drives Tough challenges call for innovative solutions, and General Cable is your worldwide source for new products and a wide range of industry-leading
MV CABLE TYPE C 33-226
MV CABLE TYPE C 33-226 Standards : CENELEC HD 620 C 33-226 Rated voltage Rated voltage : 12/20 (24) kv Design 1 Stranded aluminium, class 2 conductor 2 Extruded conducting screen on conductor 3 XLPE insulation
FLEXIBLE INDUSTRIAL CABLES H07RN-F TENAFLEX SR
FLEXIBLE INDUSTRIAL CABLES H07RN-F TENAFLEX SR Standards : CENELEC HD 22.4 NF C 32-102-4 DIN VDE 0282-1 and VDE 0282-4 BS 6007 and BS 6500 IEC 60245-4 Rated voltage Rated voltage: 450/750 V (Use up to
David O Brien, CMP Products ([email protected])
David O Brien, CMP Products ([email protected]) 1) Main Function of Cable Glands 2) Common Issues with Cable Glands 3) Compliance / Standards, changing times 4) How do we select Cable Glands?
COAX Cables Radio Frequency Cables
COAX Cables Radio Frequency Cables Contents Page Table of contents Pictographs General information Introduction Types and abbreviations Temparature range Construction Characteristics Special constructions
RF & Microwave cable assemblies C291
ERTIFIED C AS 9100 RF & Microwave cable assemblies C291 B CONTENTS Pages Introduction... B-4 Specify the right cable for your application... B-5 Finder guide cables vs insertion loss... B-6 to B-7 Flexible
Terminal Boxes Series 8146
Series > Enclosures in shock-resistant glass fibre reinforced polyester resin > basic enclosure sizes various heights > Fitted according to the customer's requirements > For terminals up to max. 00 mm
Flexible Control Cables
Works photo: KUKA Flexible Control Cables A Flexible Control Cables Since generations people try to build machines and plants which shall take on different functions. To raise, sink, slide, drill, transport
6 ELECTRICAL PARAMETERS
6 ELECTRICAL PARAMETERS For power, low voltage and medium voltage cables, cross section nominal areas are calculated in taking into account several parameters as: permissible current carrying capacities
Chemical resistance Accidental
Industrial flexible cable, insulation and outer sheath in elastomer Description Application TITANEX flexible cable is intended for installations with moving equipment, electric appliances and for building
SECTION 18370 SIGNAL WIRE AND CABLE
SECTION 18370 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for all cable and wire required for signal and signal power system wiring to wayside shelters, junction boxes, and factory
6000 Series Buccaneer. 30 twist locking Tamperproof lock prevents accidental un-mating. Cat 5e shielded coupler Maintains shielding
circular connectors that combine the ease of use of a push/pull coupling mechanism with proven environmental sealing. Available with metal or plastic bodies, the range supports both data (USB and Ethernet),
< SD 200 C TP Continuously flexible TPE/PUR paired data cable with coloured cores and overall copper screen... 10
CONTENT General < The Company..................................................................................... 3 Customized cables for different applications < Data / POF Cables POF-LWL and hybrid
Fire retardant IEC 60332-1
300 / 500 V Description Approval Certificates VDE Reg N 7691 Application In dry and moist rooms for light mechanical stresses. Outdoors only when protected. Not in water. As supply and interconnecting
Removal of EP 20 10 00 02 SP High Voltage Cable
TN 018: 2014 Technical Note For queries regarding this document [email protected] www.asa.transport.nsw.gov.au TN 018: 2014 Issued date 12 March 2014 Effective dates 12 March 2014 Subject:
Fire Performance Standard
Fire Performance Standard At present, in cable industry, Fire Retardant, Low Smoke Halogen Free (LSZH), Low Smoke Fume (LSF) and Fire Resistant cables are all described as Fire survival Cables. Flame Retardant
450-750 VOLTS - Copper conductor PVC insulated SSA 1320, IEC 60227 & BS 6004 HO 7V - U With Solid Conductor - TYPE 60227 IEC 01. Insulation Thickness
450 50 VOLTS Copper conductor PVC insulated SSA 320, IEC 6022 & BS 6004 HO V U With Solid TYPE 6022 IEC 0 For internal wiring equipment rated voltage up to 000 V AC and up to 50 V to earth. Catalogue Number
T A B L E T 1 T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A
T A B L E T 1 1 of 7 Tests & Inspection Cable PCUT & PCUT-A (Table T1) T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A No. Test Scale MOC Requirements G 20:10:001:01 Defined Test
MICROCABLES. A complete vision of your connectivity needs. Catalogue
MICROCABLES A complete vision of your connectivity needs Catalogue ELECTRONIC Filotex Introduction Application Nexans s line of microcables is designed towards the increasing requirements of electronics