Specializing in the cable business for over 38 years, PT. SUPREME CABLE
|
|
- Bethanie Logan
- 8 years ago
- Views:
Transcription
1 Specializing in the cable business for over 38 years, PT. SUPREME CABLE MANUFACTURING & COMMERCE Tbk. (PT. SUCACO Tbk) has grown steadly to become a largest and leading cable manufacturer, with international reputation for quality and reliablity. Established in 1970, PT SUCACO Tbk. is a pioneer in the modern industry. With technical assistance from Furukawa Electric Co Ltd Japan and International Executives Service Corp, USA, the company began commercial opens in We produce and markets power cable upto 150 kv, optical and telecommunication cables, control cables, instrumentation cables, coaxial cables and enamelled s under brand name of SUPREME. The Company is also involved through its affiliated companies, in various line of business. The company has a Quality Assurance Program and ISO 9001 certificate from SGS international certification body of quality management system. Today, PT SUCACO Tbk. has grown to become a reliable partner in infrastructures, buildings and various projects.
2 PE/XLPE insulation PAGE PVC insulation PAGE CSEV 3 ~ 4 Single and multi, PE insulation,, PVC outer sheath. CSCV-TCWB 5 ~ 6 Single and multi, XLPE insulation,, braiding, PVC outer sheath. PSEV 7 ~ 8 Single and multi, PE insulation, Individual and, PVC outer sheath. PSCV-TCWB 9 ~ 10 Single and multi, XLPE insulation, Individual and, braiding, PVC outer sheath. CSEV-SWA 11 ~ 12 Single and multi, PE insulation,, galvanized round steel armour, PVC outer sheath. PSEV-SWA 13 ~ 14 Single and multi, PE insulation, Individual and overall, galvanized round steel armour, PVC outer sheath. CSEV-LS/SWA 15 ~ 16 Single and multi, PE insulation,, lead sheath, galvanized round steel armour, PVC outer sheath. PSEV-LS/SWA 17 ~ 18 Single and multi, PE insulation, Individual and overall, lead sheath, galvanized round steel armour, PVC outer sheath. CSVV 25 ~ 26 Single and multi, PVC insulation,, PVC outer sheath. CSVV-TCWB 27 ~ 28 Single and multi, PVC insulation,, braiding, PVC outer sheath PSVV 29 ~ 30 Single and multi, PVC insulation, Individual and, PVC outer sheath. PSVV-TCWB 31 ~ 32 Single and multi, PVC insulation, Individual and, braiding, PVC outer sheath. MSVV 33 ~ 34 Multi cores, PVC insulation,, PVC outer sheath. CSVV-SWA 35 ~ 36 Single and multi, PVC insulation,, galvanized round steel armour, PVC outer sheath. PSVV-SWA 37 ~ 38 Single and multi, PVC insulation, Individual and overall, galvanized round steel armour, PVC outer sheath. MSVV-SWA 39 ~ 40 Multi cores, PVC insulation,, galvanized round steel armour, PVC outer sheath. CSEV ALCA 19 ~ 20 Single and multi, PE insulation,, aluium corrugated armour, PVC outer sheath. PSEV ALCA 21 ~ 22 Single and multi, PE insulation, Individual and overall, aluium corrugated armour, PVC outer sheath.
3
4 csev Suitable used in duct, cable tray or conduit for control, service typically in industrial project, petroleum or oil and gas industry. Conductor : or. 1, 2 or 5 based on IEC or BS : Polyethylene (PE) type 03 to BS Pairs colour code Triads colour code ing : Black, White with number printing on insulation. : Black, White, Red with number printing on insulation. : Twisted are assembled with non-hygrscopic fillers tape and with strand copper and aluium foil tape. Orange colour. marking CSEV Single & multi, PE insulated,, PVC sheathed BS mm 2 : SUPREME CABLE CSEV SIZE 300/500 V with interval marking thickness Weight mm Kg/km m mm / / / / / / / / / / / / / / / / , / / / / / / / , / , / / / / / / / / , Conductor, max copper - pf/250 m pf/m radius, Unbalance Core to Volt / 1 ute O
5 cscv-tcwb thickness Outer sheath Diameter of copper braiding Weight radius, CSCV-TCWB 300 Volt Single & multi, XLPE insulated,, braiding, PVC sheathed BS EN mm 2 mm mm Kg/km m mm / / / / / / / Conductor, max any core or pf/m Volt / 1 ute Core to service typically in industrial project, petroleum or oil and gas industry. Conductor : XLPE to BS Pairs colour code Triads colour code : or. 1, 2 or 5 based on IEC or BS : Black, White with number printing on insulation. : Black, White, Red with number printing on insulation. ing Braid ing : Twisted are assembled with non-hygroscopic fillers tape and with strand copper and aluium foil tape. : Extruded Polyvinyl Chloride (PVC), : to protect against electromagnetic noise.. : Extruded Polyvinyl Chloride (PVC), TM1 type to BS 6746, marking : SUPREME CABLE CSCV-TCWB SIZE 300 V with interval marking Operating temperature maximum 90 C 5 6
6 Suitable used in duct, cable tray or conduit for control, communication, data (analog/digital) and voice transmission signals and service typically in industrial project, petroleum or oil and gas industry. PSEV Single & multi, PE insulated, Individual and overall, PVC sheathed BS Conductor : or. 1, 2 or 5 based on IEC or BS : Polyethylene (PE) type 03 to BS Pairs colour code Triads colour code Individual ing ing : Black, White with number printing on insulation. : Black, White, Red with number printing on insulation. : Each pair is with strand copper and aluium foil tape to give a maximum protection against electrostatic noise and crosstalk interference. : All s are isolated from each other. Individually are assembled with non-hygroscopic fillers tape and with strand copper and aluium foil tape. psev thickness Ind. and overall Weight mm Kg/km m mm / / / / / / / , / / / / / / , / , / / / / / , / , / , / / / / / / , / , , s Unbalance - pf/250 m pf/m radius, Core to Volt / 1 ute marking : SUPREME CABLE PSEV SIZE 300/500 V with interval marking 7 8
7 pscv - tcwb thickness Ind. and overall copper drain Diameter of braiding Weight PSCV-TCWB 300 Volt Single & multi, XLPE insulated, Individual and overall, braiding, PVC sheathed BS EN pcs/mm mm mm 2 mm mm Kg/km m mm / / / / , s any core or pf/m Max. L/R Core to Volt / 1 ute service typically in industrial project, petroleum or oil and gas industry. Conductor : or. 1, 2 or 5 based on IEC or BS : XLPE to BS Pairs colour code : Black, White with number printing on insulation. Triads colour code : Black, White, Red with number printing on insulation. Individual ing ing Braid ing : Each pair is with strand copper and aluium foil tape to give a maximum protection against electrostatic noise and crosstalk interference. : All s are isolated from each other. Individually are assembled with non-hygroscopic fillers tape and with strand copper and aluium foil tape. : Extruded Polyvinyl Chloride (PVC), : to protect against electromagnetic noise. : Extruded Polyvinyl Chloride (PVC), TM1 type to BS 6746, marking : SUPREME CABLE PSCV-TCWB SIZE 300 V with interval marking Operating temperature maximum 90 C 9 10
8 service typically in industrial project, petroleum or oil and gas industry. CSEV-SWA Single & multi, PE insulated,, Armoured, PVC sheathed BS Conductor : or. 1, 2 or 5 based on IEC or BS : Polyethylene (PE) type 03 to BS Pairs colour code Triads colour code ing Armouring : Black, White with number printing on insulation. : Black, White, Red with number printing on insulation. : Twisted are assembled with non-hygroscopic fillers tape and with strand copper and aluium foil tape. : Extruded Polyvinyl Chloride (PVC), : Galvanized round steel. marking : SUPREME CABLE CSEV-SWA SIZE 300/500 V with interval marking csev - swa thickness Outer sheath Dia of armour Weight mm mm Kg/km m mm / / / / / / , / , / , / / / / , / , / , / , / , / / / / , / , / , / , / , / / / / / , / , / , / , Unbalance - pf/250 m pf/m Max. L/R Volt / 1 ute Core to 11 12
9 service typically in industrial project, petroleum or oil and gas industry. INSTRUMENTATIO CABLE PSEV-SWA Single & multi, PE insulated, Individual and overall, Armoured, PVC sheathed BS Conductor : or. 1, 2 or 5 based on IEC or BS : Polyethylene (PE) type 03 to BS Pairs colour code : Black, White with number printing on insulation. Triads colour code : Black, White, Red with number printing on insulation. Individual ing ing : Each pair is with strand copper and aluium foil tape to give a maximum protection against electrostatic noise and crosstalk interference. : All s are isolated from each other. Individually are assembled with non- hygroscopic fillers tape and with strand copper and aluium foil tape. : Extruded Polyvinyl Chloride (PVC), Armouring : Galvanized round steel. Blue colour. marking : SUPREME CABLE PSEV-SWA SIZE 300/500 V with interval marking psev-swa thickness Ind. and overall Dia of armour Weight - pcs/mm mm mm 2 mm mm Kg/km m mm / / / , / , / , / , / , / / / , / , / , / , / , / / , / , / , / , / , / , / / / , / , / , / , / , , s Unbalance - pf/250 m pf/m Core to Volt / 1 ute 13 14
10 csev - LS/swa thickness Lead sheath Dia of armour Weight service typically in industrial project, petroleum or oil and gas industry chemical plant and in in which ground water contains waste oils or sulfides. CSEV-LS/SWA CSEV-LS/SWA Single & multi, PE insulated,, Lead sheathed, Armoured, PVC sheathed BS Conductor : or. 1, 2 or 5 based on IEC or BS : Polyethylene (PE) type 03 to BS Pairs colour code : Black, White with number printing on insulation. Triads colour code ing Bedding/filler Lead sheath Armouring : Black, White, Red with number printing on insulation. : Twisted are assembled with non-hygroscopic fillers tape and with strand copper and aluium foil tape. : Extruded Polyvinyl Chloride (PVC) filler. : Lead alloy E grade. : Extruded Polyvinyl Chloride (PVC), : Galvanized round steel. : Extruded Polyvinyl Chloride (PVC), TM1 type to BS 6746, Orange colour. marking. : SUPREME CABLE CSEV-LS/SWA SIZE 300/500 V with interval marking mm mm Kg/km m mm / / / , / , / , / , / , / , / / / , / , / , / , / , / , / / , / , / , / , / , / , / , / / / , / , / , / , / , / , Unbalance - pf/250 m pf/m Volt / 1 ute Core to 15 16
11 psev LS swa thickness Lead sheath Ind. and Dia of armour Weight service typically in industrial project, petroleum or oil and gas industry, chemical plant and in in which ground water contains waste oils or sulfides. PSEV-LS/SWA Single & multi, PE insulated, Individual and overall, Lead sheathed, Armoured, PVC sheathed BS Conductor : or. 1, 2 or 5 based on IEC or BS : Polyethylene (PE) type 03 to BS Pairs colour code : Black, White with number printing on insulation. Triads colour code : Black, White, Red with number printing on insulation. Individual ing ing : Each pair is with strand copper and aluium foil tape to give a maximum protection against electrostatic noise and crosstalk interference. : All s are isolated from each other. Individually are assembled with non-hygroscopic fillers tape and with strend copper and aluium foil tape. Bedding/filler : Extruded Polyvinyl Chloride (PVC) filler. Lead sheath : Lead alloy E grade. : Extruded Polyvinyl Chloride (PVC), Armouring : Galvanized round steel. marking : SUPREME CABLE PSEV-LS/SWA SIZE 300/500 V with interval marking mm mm Kg/km m / , / , / , / , / , / , / , / , / , / , / , / , / , / , / , / , / , / , / , / , / , / , / , / , / , / , / , / , , s Unbalance Core to - pf/250 m pf/m Volt / 1 ute
12 csev alca thickness Dia of corrugated armour Weight service typically in industrial project, petroleum or oil and gas industry. available upon the customer request. CSEV ALCA Single & multi, PE insulated,, Corrugated armoured, PVC sheathed BS Conductor : or. 1, 2 or 5 based on IEC or BS : Polyethylene (PE) type 03 to BS Pairs colour code Triads colour code ing : Black, White with number printing on insulation. : Black, White, Red with number printing on insulation. : Twisted are assembled with non-hygroscopic fillers tape and with strand copper and aluium foil tape. : Extruded Polyvinyl Chloride (PVC), Armouring : Corrugated aluium tape : Extruded Polyvinyl Chloride (PVC), TM1 type to BS 6746, marking Operating temperature maximum 70 C : SUPREME CABLE CSEV ALCA SIZE 300/500 V with interval marking mm mm Kg/km m mm / / / / / / / , / , / / / / / , / , / , / , / / / / , / , / , / , / , / / / / / / / , / , Conductor, max Unbalance Core to - pf/250 m pf/m Volt / 1 ute
13 psev alca thickness Ind. and overall Dia of corrugated armour Weight service typically in industrial project, petroleum or oil and gas industry. available upon the customer request. PSEV ALCA Conductor Single & multi, PE insulated, Individual and overall, Corrugated armoured, PVC sheathed BS : or. 1, 2 or 5 based on IEC or BS : Polyethylene (PE) type 03 to BS Pairs colour code : Black, White with number printing on insulation. Triads colour code : Black, White, Red with number printing on insulation. Individual ing ing Armouring : Each pair is with strand copper and aluium foil tape to give a maximum protection against electrostatic noise and crosstalk interference. : All s are isolated from each other. Individually are assembled with non-hygroscopic fillers tape and with strand copper and aluium foil tape. : Extruded Polyvinyl Chloride (PVC), : Corrugated aluium tape. Orange colour. marking : SUPREME CABLE PSEV ALCA SIZE 300/500 V with interval marking mm mm Kg/km m mm / / / / , / , / , / , / / / , / , / , / , / , / / / , / , / , / , / , / / / / , / , / , / , , s Unbalance Core to - pf/250 m pf/m Volt / 1 ute
14
15 csvv thickness Weight Suitable used in duct, cable tray or conduit for control, communication, data (analog/digital) and voice transmission signals and service typically in industrial project, petroleum or oil and gas industry. Conductor CSVV Single & multi, PVC insulated,, PVC sheathed BS : or. 1, 2 or 5 based on IEC or BS : Polyvinyl Chloride (PVC) type T1 to BS Pairs colour code Triads colour code ing : Black, White with number printing on insulation. : Black, White, Red with number printing on insulation. : Twisted are assembled with non-hygroscopic fillers tape and with strand copper and aluium foil tape. Orange colour. marking : SUPREME CABLE CSVV SIZE 300/500 V with interval marking mm 2 mm Kg/km m mm / / / / / / / / , / / / / / / / / , / / / / / / , / , / , any core or pf/m Max. L/R Volt / 1 ute Core to 25 26
16 csvv-tcwb CSVV-TCWB 300 Volt Single & multi, PVC insulated,, braiding, PVC sheathed BS EN thickness any core or Diameter of braiding - pf/m Weight mm mm Kg/km m mm / / / / / / / Volt / 1 ute Core to service typically in industrial project, petroleum or oil and gas industry. Conductor : or. 1, 2 or 5 based on IEC or BS : Polyvinyl Chloride (PVC) type T1 to BS Pairs colour code : Black, White with number printing on insulation. Triads colour code : Black, White, Red with number printing on insulation. ing Braid ing : Twisted are assembled with non-hygroscopic fillers tape and with strand copper and aluium foil tape. : Extruded Polyvinyl Chloride (PVC), : to protect against electro magnetic noise. marking : SUPREME CABLE CSVV-TCWB SIZE 300 V with interval marking Operting temperature maximum 70 C 27 28
17 psvv thickness Ind. and overall Weight PSVV Single & multi, PVC insulated, Individual and overall, PVC sheathed BS mm Kg/km m mm / / / / / / , / , / / / / / , / , / , / / / / , / , / , / , Suitable used in duct, cable tray or conduit for control, service typically in industrial project, petroleum or oil and gas industry. halogen. Conductor : or. 1, 2 or 5 based on IEC or BS : Polyvinyl Chloride (PVC) type T1 to BS Pairs colour code : Black, White with number printing on insulation. Triads colour code Individual ing : Black, White, Red with number printing on insulation. : Each pair is with strand copper and aluium foil tape to give a maximum protection against electrostatic noise and crosstalk interference. ing : All s are isolated from each other. Individually are assembled with non-hygroscopic fillers tape and with strand copper and aluium foil tape. Conductor, max, s any core or pf/m Core to Volt / 1 ute marking : SUPREME CABLE PSVV SIZE 300/500 V with interval marking 29 30
18 psvv- tcwb thickness Ind. and overall Diameter of braiding Weight PSVV-TCWB 300 Volt Single & multi, PVC insulated, Individual and overall, braiding, PVC sheathed BS EN mm Kg/km m mm / / / / , s any core or pf/m Volt / 1 ute Core to service typically in industrial project, petroleum or oil and gas industry. Conductor : or. 1, 2 or 5 based on IEC or BS : Polyvinyl Chloride (PVC) type T1 to BS 7655 Pairs colour code : Black, White with number printing on insulation. Triads colour code : Black, White, Red with number printing on insulation. Individual ing ing Braid ing : Each pair is with strand copper and aluium foil tape to give a maximum protection against electrostatic noise and crosstalk interference. : All s are isolated from each other. Individually are assembled with non-hygroscopic fillers tape and with strand copper and aluium foil tape. : Extruded Polyvinyl Chloride (PVC), : to protect against electromagnetic noise. marking : SUPREME CABLE PSVV-TCWB SIZE 300 V with interval marking every (one) meter
19 msvv cores thickness Weight Suitable used in duct, cable tray or conduit for control, service typically in industrial project, petroleum or oil and gas industry. MSVV Multicores, PVC insulated,, PVC sheathed BS Conductor : or. 1, 2 or 5 based on IEC or BS : Polyvinyl Chloride (PVC) type T1 to BS Identification of cores Cores lay-up ing : Black with white number printing on insulation. : All cores are concentrically laid-up to counter electro magnetic noise. : Multicores are assembled with non-hygroscopic fillers tape and with strand copper and aluium foil tape. marking : SUPREME CABLE MSVV SIZE 300/500 V with interval marking mm Kg/km m mm / / / / / / / / / / / / / / / / / / / ~ / / , any core or pf/m Volt / 1 ute Core to 33 34
20 csvv-swa thickness Dia of armour Weight service typically in industrial project, petroleum or oil and gas industry. CSVV-SWA Single & multi, PVC insulated,, Armoured, PVC sheathed BS Conductor : or. 1, 2 or 5 based on IEC or BS : Polyvinyl Chloride (PVC) type T1 to BS 7655 Pairs colour code : Black, White with number printing on insulation. Triads colour code ing Armouring : Black, White, Red with number printing on insulation. : Twisted are assembled with non-hygroscopic fillers tape and with strand copper and aluium foil tape. : Extruded Polyvinyl Chloride (PVC), : Galvanized round steel. : Extruded Polyvinyl Chloride (PVC), TM1 type to BS 6746, mm 2 mm mm Kg/km m mm / / / / , / , / , / , / , / / / / , / , / , / , / , / / / / , / , / , / , / , any core or pf/m Volt / 1 ute Core to marking : SUPREME CABLE CSVV-SWA SIZE 300/500 V with interval marking Operating temperature maximum 70 C 35 36
21 psvv-swa thickness Ind. and overall Dia of armour Weight service typically in industrial project, petroleum or oil and gas industry. PSVV-SWA Single & multi, PVC insulated, Individual and overall, Armoured, PVC sheathed BS Conductor : or. 1, 2 or 5 based on IEC or BS : Polyvinyl Chloride (PVC) type T1 to BS 7655 Pairs colour code : Black, White with number printing on insulation. Triads colour code : Black, White, Red with number printing on insulation. Individual ing ing : Each pair is with strand copper and aluium foil tape to give a maximum protection against electrostatic noise and cross talk interference. : All s are isolated from each other. Individually are assembled with non-hygroscopic fillers tape and with strand copper and aluium foil tape. : Extruded Polyvinyl Chloride (PVC), Armouring : Galvanized round steel. Blue colour. marking : SUPREME CABLE PSVV-SWA SIZE 300/500 V with interval marking mm mm Kg/km m mm / / / , / , / , / , / , / / / , / , / , / , / , / / , / , / , / , / , / , , s any core or pf/m Max. L/R Core to Volt / 1 ute 37 38
22 msvv-swa cores thickness Dia of armour Weight (analog/digital) and voice transmission signals and service typically in industrial project, petroleum or oil and gas industry. Other construction suchas MSVV-SWA Conductor : or. 1, 2 or 5 based on IEC or BS : Polyvinyl Chloride (PVC) type T1 to BS Identification of cores : Black with white number printing on insulation. Cores lay-up ing : All cores are concentrically laid-up to counter electro magnetic noise. : Multicores are assembled with non-hygroscopic fillers tape and with strand copper and aluium foil tape. : Extruded Polyvinyl Chloride (PVC), Armouring : Galvanized round steel. : Extruded Polyvinyl Chloride (PVC), TM1 type to BS 6746, marking Multicores, PVC insulated,, Armoured, PVC sheathed BS : SUPREME CABLE MSVV-SWA SIZE 300/500 V with interval marking mm mm Kg/km m mm / / / / / / / , / / / / / / / , / / / / / / , / , any core or pf/m Volt / 1 ute Core to 39 40
23 Notes
CONFLEX ELECTRIC CABLE
CONFLEX ELECTRIC CABLE CONFLEX - 0.6/1kV Flexible VSD/EMC Cables Applications WW VSD/EMC cables are manufactured for use where electrical interference distorts signal transmission in electric motors. Standard
More informationQuality Reliability Innovation. ISO 9001 : 2000 CERTIFIED BY AFAQ No. QUAL / 1997 / 7034 a COPPER TELECOMMUNICATION CABLES
Quality Reliability Innovation ISO : CERTIFIED BY AFAQ No. QUAL / 7 / 7 a COPPER TELECOMMUNICATION CABLES COPPER TELECOMMUNICATION CABLES CONTENTS 7 NOTICE INTRODUCTION QUALITY ASSURANCE RECOMMENDED ORDERING
More informationOutside Telephone Cable
Outside Telephone Cable Filled Core. Moisture Barrier. Description Soft copper wires insulated with high density polyethylene, foam skin or solid. Filled core, conformed by groups of pairs or by unit of
More information3.6/6 kv XLPE insulated cables 5. 6/10 kv XLPE insulated cables 15. 8.7/15 kv XLPE insulated cables 25. 12/20 kv XLPE insulated cables 35
CONTENTS INTRODUCTION 1 Cable selection, cable specification, cable services CABLES Constructional data: 3.6/6 kv XLPE insulated cables 5 SECTION 1 6/10 kv XLPE insulated cables 15 SECTION 2 8.7/15 kv
More informationFIRE RESISTANT CABLE CONSTRUCTION OF CABLES
FIRE RESISTANT CABLE In all fire disasters, fire smoke, heat and toxic fumes are the main obstacles to safe evacuation of a building or area. A major contribution towards overcoming these hazards is the
More informationCommunication, Signal & Data Cables
Communication, Signal & Data Cables Used for indoor installation and interconnection of transmission, telephone, telegraph and electronic equipment as well as media equipments www.alfanar.com Communication
More informationGulf Cable & Electrical Ind. Co.
CONTENTS INTRODUCTION PRODUCT RANGE I PRODUCT DATA TABLES Irrigation 1 Coaxial s for T.V/ Satellite Antenna etc 2 Data Transmission s - 4 pair 24 AWG 3 TELEPHONE CABLES Telephone cables CCP-LAP & CCP-LAP-SS
More informationMarine & Shipboard Cable JIS C 3410(1999) IEC 60092-350, 353, 354, 376
T o t a l S o l u t i o n o f M a r i n e C a b l e Marine & Shipboard Cable JIS C 3410(1999) IEC 60092-350, 353, 354, 376 Marine & Shipboard cable Total Solution of Marine Cable JIS C 3410(1999), IEC
More informationUGVCL/SP/591/11KV HT AB CABLE
TECHNICAL SPECIFICATION FOR 11KV AERIAL BUNCHED CABLES FOR OVERHEAD LINES (CROSSED LINKED POLYTHENE DRY GAS CURED) 1. SCOPE This specification covers requirements of XLPE insulated, 11 KV Aerial Bunched
More informationwww.ptranscable.com We specialize in low voltage cables including: Stranded Single Cable H07V-R Flexible Single Cable H05V-K
P-trans, meaning power transistor, is a well known cable manufacturer based in Aan - Jordan. The production plant produces all sorts of high quality low tension cables and is a leader in the industry supplying
More informationCorporate Profile ROYAL. MODERN ROYAL ELECTRIC Ideal Power Solution MRE ELECTRICAL, INSTRUMENTATION & COMMUNICATION SYSTEMS
Corporate Profile MODERN ROYAL ELECTRIC Ideal Power Solution ROYAL MRE ELECTRICAL, INSTRUMENTATION & COMMUNICATION SYSTEMS MAJOR STOCKIST >>> CATHODIC PROTECTION CABLES >>> LOW VOLTAGE CABLES >>> MEDIUM
More informationMICROCABLES. A complete vision of your connectivity needs. Catalogue
MICROCABLES A complete vision of your connectivity needs Catalogue ELECTRONIC Filotex Introduction Application Nexans s line of microcables is designed towards the increasing requirements of electronics
More informationGulf Cable & Electrical Ind. Co.
CONTENTS INTRODUCTION PRODUCT RANGE I PRODUCT DATA TABLES XLPE INSULATED 600/1000V CABLES Two Core Cables CU/XLPE/PVC/LC/PVC/SWA/PVC 1 Three Core Cables CU/XLPE/PVC/LC/PVC/SWA/PVC 2 Four Core Cables CU/XLPE/PVC/LC/PVC/SWA/PVC
More informationCOAX Cables Radio Frequency Cables
COAX Cables Radio Frequency Cables Contents Page Table of contents Pictographs General information Introduction Types and abbreviations Temparature range Construction Characteristics Special constructions
More informationT A B L E T 1 T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A
T A B L E T 1 1 of 7 Tests & Inspection Cable PCUT & PCUT-A (Table T1) T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A No. Test Scale MOC Requirements G 20:10:001:01 Defined Test
More informationwith coloured cores and overall copper screen UL/CSA... 17
CONTENT Cable Track Cables y SD 200 extremely flexible TPE/PUR data cable with coloured cores for continuous movement..... 6 y S 200 extremely flexible TPE/PUR control cable with numbered cores for continuous
More informationLEAD FREE FIREX. Interlock Armored Cables TECK90 and MC Industrial Cables. w w w. n e x a n s e n e r g y. c o m
FIREX Interlock Armored Cables TECK90 and MC Industrial Cables LEAD FREE O V E R 1 8 0 Y E A R S O F E X P E R I E N C E 866-663-9267 w w w. n e x a n s e n e r g y. c o m Interlock Armored Cables Introduction....2
More informationScottishPower Distribution Cables & Equipment. Metal Theft
ScottishPower Distribution Cables & Equipment Metal Theft April 2012 As an aid to deterring to metal theft this booklet has been put together to help identify the types of utility power cables and associated
More informationCatalogue Câbles d Energie
Catalogue Câbles d Energie Conductores Tecnológicos S.A. www.contecsa.es Index Page Introduction 13 RV 14 RVMV 15 RVSV 16 RVFV 17 Conductores Tecnológicos S.A. 2 www.contecsa.es INTRODUCTION Câbles d Energie
More informationHINDUSTAN PETROLEUM CORPORATION LIMITED ENGINEERING & PROJECTS GRESHAM ASSURANCE HOUSE, 2 ND FLOOR, A-1595(3) 1-A, SIR P M ROAD, FORT MUMBAI-400 001
NEW POL DEPOT AT HINDUSTAN PETROLEUM CORPORATION LIMITED ENGINEERING & S GRESHAM ASSURANCE HOUSE, 2 ND FLOOR, A-1595(3) 1-A, SIR P M ROAD, FORT MUMBAI-400 001 TECHNICAL SPECIFICATION OF XLPE, FRLS LT CABLES
More informationSpecification SFTP CAT6 Network Cable 23AWG CU
Specification SFTP CAT6 Network Cable 23AWG CU S/FTP CAT6 Shielded S/FTP PVC Cable 23AWG 4pair Solid, Wooden drum 1000 Grey CAT6 600MHZ CM Shielded (S/FTP) Solid Cable: Our CAT6 600MHZ Shielded (S/FTP)
More informationGlobal cable expertise for rolling stock
Global cable expertise for rolling stock Global cable expertise for rolling stock Single and multicore Low voltage control cables Jumper cables HV roof cables (25 kv) rubber cables for power needs of locomotives
More informationBuilding Cables and Wires
Building Cables and Wires 4 Introduction alfanar is equipped with state-of-the-art manufacturing facilities such as latest machineries, instrumentation, quality control and testing laboratory, etc., for
More informationMacArtney Underwater Cables - In stock
MacArtney Underwater Cables - In stock The MacArtney Group depends on the support of a number of major cable manufacturers to supply a range of cables that are designed, manufactured and tested to meet
More informationFire Resistant Cables
109/4 Fire Resistant Cables SR 114H Standard - SR 114E Enhanced BS 5839-1 BS 7629-1 BS 6387 BS 8434-1/2 BS 6425 BS 7622 EN 50200 World-wide recognized high quality cables Firecel SR114 are used in: Data
More informationMEDIUM VOLTAGE CABLES Up to and including 36 KV
MEDIUM VOLTAGE CABLES Up to and including 6 KV NOTICE As this catalogue is not intendedto cover all of LIBAN CABLES SAL possibilities in special cables manufacturing, the hereafter listing of the types
More informationCAVEL VS80205 MADE IN ITALY 1000 V
0,05 9,00 x 7,20 (Pet) (LSZH) Attached CE01 CE02 Sheath Colour black black red Non-migrating Polyester tape longitudinally overlapped (Pet) 25 x 23 µm Outer sheath of Thermoplastic material - black - halogen-free,
More informationTFC/U-JIN Coaxial Cable Product Information Sheet Type: TU6T60-JVB
Type: TU6T60-JVB Dielectric 2nd Outer (w/optional Floodant) Series 6 Coaxial Cable Copper Clad Steel Foamed Polyethylene Dielectric Bonded AP Laminate Shield 60% Aluminum Braid "Life Time" compound AP
More informationAirdac CNE and SNE, 600/1000V, Polyethylene Sheath, SANS 1507, NRS 063 & NRS 017
Airdac CNE and SNE, 600/1000V, Polyethylene Sheath, SANS 1507, NRS 063 & NRS 017 Conductor: Hard Drawn Copper Conductor Class 2 Insulation: LV-XLPE Phase Color Code(SNE): Red, Black & Bare Copper Phase
More informationThe Quality Connection. BETAflam Fire Resistant Safety Cables
The Quality Connection BETAflam Fire Resistant Safety Cables 2 Contact Consulting and sales Switzerland Phone +41 (0)62 288 82 82 Fax +41 (0)62 288 83 83 sales@leoni-studer.ch www.leoni-infrastructure-datacom.com
More informationPROFIBUS cable. for PROFIBUS-PA and -DP 10/63-6.46 EN
for PROFIBUS-PA and -DP 10/63-6.46 EN CPN 080/CPE 080-Ex PROFIBUS-PA basis cable AWG 18, 0.88 mm 2 Use For fixed installation indoor and outdoor, on racks and in conduits. Application Fieldbus cable for
More informationSCHEDULE ' A' TECHNICAL SPECIFICATION FOR 11/22/33KV H.T.XLPE POWER CABLE FOR DISTRIBUTION NETWORK IN MAHARASHTRA (SPECIFICATION NO.
SCHEDULE ' A' TECHNICAL SPECIFICATION FOR 11/22/33KV H.T.XLPE POWER CABLE FOR DISTRIBUTION NETWORK IN MAHARASHTRA (SPECIFICATION NO.MM/I/HTXLPE/2006) MAHARASHTRA STATE ELECTRICITY DISTRIBUTION CO.LTD.
More informationFestoon 715 P PUR cable for flexible application in festoon systems
CABLES FOR CRANE AND CONVEYOR APPLICATIONS Festoon 715 P PUR cable for flexible application in festoon systems S AB BRÖCKSKES D-VIERSEN Festoon 715 P 1 x 16.0 mm 2 C Marking for Festoon 715 P 07150162:
More informationRoHS DATA, COAXIAL AND ELECTRONIC M.R. D A TA, C O A X I A L, ECOLGICAL Telecom Cables A N D EL E CTRON I C. Cables
RoHS DATA, COAXIAL AND ELECTRONIC D A TA, C O A X I A L, A N D EL E CTRON I C Cables Index SOLID MULTI-CONDUCTOR CABLES STRANDED MULTI-CONDUCTOR CABLES SPEAKER/ZIP WIRE THERMOSTAT CABLE FIRE ALARM CABLE
More informationCables. Accessories. For Force, Torque and Strain Sensors
Accessories Cables For Force, Torque and Strain Sensors Charge mode, high impedance piezoelectric measurement demands highly insulated coaxial cables and connectors to ensure an insulation resistance greater
More informationImportant Information: Complete Terms and Conditions are printed on sales invoices
Important Information: Complete Terms and Conditions are printed on sales invoices Notice: L&H Group is continually working to improve and add new products to the Cable Express product range. For this
More informationThe Instrumentation Cable Experts
1 The Instrumentation Cable Experts Facilities Head office & factory 1300 Industrial Boulevard Mt Pleasant, Texas 75455, USA www.dekoroncable.com Stocking Centres USA Mt Pleasant and Houston Singapore
More informationUnarmored Variable Frequency Drive (VFD) Cable Termination Guide
Authorized Distributor Unarmored Variable Frequency Drive (VFD) Cable Termination Guide Be Certain with Belden A Step-by-Step Look at the Connection/Termination of Unarmored VFD Cables Terminating Unarmored
More informationFlexible Control Cables
Works photo: KUKA Flexible Control Cables A Flexible Control Cables Since generations people try to build machines and plants which shall take on different functions. To raise, sink, slide, drill, transport
More informationIndustrial Cable Solutions for Variable Frequency Drives
Industrial Cable Solutions for Variable Frequency Drives Tough challenges call for innovative solutions, and General Cable is your worldwide source for new products and a wide range of industry-leading
More informationCopper Cables CONNECTIVITY & CABLING SYSTEM
Copper Cables CONNECTIVITY & CABLING SYSTEM Category 5E M0502057-91 EN CPR 6707 U/UTP tested up to 200 MHz U/UTP CAT5E, unshielded 4-pair cable (100 Ohm), with PVC or LSZH (Low Smoke Zero Halogen) outer
More informationKNOW YOUR OPTIONS: 230 KV POWER CABLES
KNOW YOUR OPTIONS: 230 KV POWER CABLES 71 CONDUCTOR MATERIAL AND SIZE Conductor material is a matter of both customer preference and required current carrying capacity At 230 kv, copper is most common
More informationTri-Rated Flexible PVC Equipment Wire
Application: High temperature, flame retardant wire designed for use in the switch control, relay and instrumentation panels of power switchgear and for purposes such as internal connectors in rectifier
More information144Fibre SM (G.652) Loose Tube Micro Lite Duct Optical Fibre Cable PRODUCT INFORMATION
Fiber Single Mode Optical Fibre 144 Nos. Sterlite Fiber ITU.T - G.652 D Maximum Cabled Fibre Attenuation db/km 1310nm : 0.36 & 1550nm : 0.23 Loose Tube Filling Jelly Fiber/Tube 24 Nos. Thixotropic jelly
More informationTechnical cable guide
Technical cable guide November 2014 One stop-shop for all your cable needs Welcome to the latest edition of the Technical Cable Guide. Following the recent acquisition of Draka, the Prysmian Group is now
More informationSession 14 Cable Support Systems
Session 14 Cable Support Systems Cable Support Systems in the IEC World A new IEC Standard, IEC61537 2001 has been developed If full details of the cabling layout are available then the likely cable load
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 60502-1 Second edition 2004-04 Power cables with extruded insulation and their accessories for rated voltages from 1 kv (U m = 1,2 kv) up to 30 kv (U m = 36 kv) Part 1: Cables
More informationBroadcast and Commercial AV Cabling MASTER CATALOG
Broadcast and Commercial AV Cabling MASTER CATALOG Clark Wire & Cable 408 Washington Blvd. Mundelein, IL 60060 800-222-5348 toll free 847-949-9944 local 847-949-9595 fax www.clarkwire.com Specifications
More information< SD 200 C TP Continuously flexible TPE/PUR paired data cable with coloured cores and overall copper screen... 10
CONTENT General < The Company..................................................................................... 3 Customized cables for different applications < Data / POF Cables POF-LWL and hybrid
More informationDavid O Brien, CMP Products (David.OBrien@cmp-products.com)
David O Brien, CMP Products (David.OBrien@cmp-products.com) 1) Main Function of Cable Glands 2) Common Issues with Cable Glands 3) Compliance / Standards, changing times 4) How do we select Cable Glands?
More informationInternational Electrotechnical Commission Standards
International Electrotechnical Commission Standards Standard IEC 60028 IEC 60038 IEC 60050-461 IEC 60055-1 IEC 60055-2 IEC 60092-101 IEC 60092-350 IEC 60092-351 IEC 60092-352 IEC 60092-353 IEC 60092-354
More informationVIPERFLEX ELECTRIC CABLE
VIPERFLEX Flexible Low Voltage Electric Cable - 0.6/1kV (Rubber insulated) H07 RN-F & H07 BN-F Single Core 2-Core 2-Core and Earth 3-Core and Earth 4-Core and Earth Multi-Core and Earth H07 RCN-F & H07
More informationSection 5 161 kv Power Cables
Know Your Options: 161 kv Power Cable 61 material and size material is a matter of both customer preference and required current carrying capacity Copper conductor common for larger loads When both copper
More informationLT/HT Power & Control Cables
LT/HT Power & Control s Catalogue 2014 HT Power s upto 66kV 1.1 kv Power s 1.1 kv Copper Control s ISO-9001/ 14001/18001 Certified Certification Building customer confidence by providing a wide range of
More informationTemperature Permissible ambient temperature. Weather Resistance to severe weather conditions. Impacts Cable mechanical resistance to impacts
Airfield Cables Issue 10/2003 Piktogramme Temperature Permissible ambient temperature Weather Resistance to severe weather conditions Impacts Cable mechanical resistance to impacts Chemical attacks Resistance
More informationMV CABLE TYPE C 33-226
MV CABLE TYPE C 33-226 Standards : CENELEC HD 620 C 33-226 Rated voltage Rated voltage : 12/20 (24) kv Design 1 Stranded aluminium, class 2 conductor 2 Extruded conducting screen on conductor 3 XLPE insulation
More informationFire retardant IEC 60332-1
300 / 500 V Description Approval Certificates VDE Reg N 7691 Application In dry and moist rooms for light mechanical stresses. Outdoors only when protected. Not in water. As supply and interconnecting
More informationCLEVELAND CABLE LOCATIONS
A WORLD POWER IN CABLE SUPPLY THE CABLE AND ACCESSORY CATALOGUE 2011 2 CLEVELAND CABLE LOCATIONS CLEVELAND CABLE LOCATIONS 3 As is illustrated within our catalogue, we stock a comprehensive range of cables
More informationTECHNICAL SPECIFICATION
TECHNICAL SPECIFICATION 4 PAIR UTP CABLE (ENHANCED CATEGORY 5) PVC (CM Grade) Page 1 of 6 1. SCOPE This specification is based on the specifications of UL 444, ANSI/TIA/EIA-568-B.2, UL 1685 and covers
More informationInstrumentation Cable...14-17. Power Cable...2-11. Assembly Solutions...32
Severe Cold Durability Exceeds CSA Cold Bend / Cold Impact (-0 C/-35 C) Drilling Mud Resistant Flame Retardant Certified to IEC 9-3 (33-3A) and IEEE 580 Oil Resistant Assemblies...3-33 Ester Based Mud
More informationAPPLICATION ORIENTED DESIGN OF CABLES
APPLICATION ORIENTED DESIGN OF CABLES Mrs. Rohini Bhattacharyya, Dubai cables Ltd.P. O. Box 11529,Dubai. rohinib@ducab.com Mr. Nawaf Ahmad Al Mohaideb Dubai Cables Ltd. P. O. Box 11529, Dubai. Nawaf@ducab.com
More informationIEEE POWER ENGINEERING SOCIETY CHICAGO CHAPTER THE OKONITE COMPANY WEDNESDAY JANUARY 11, 2006 JIM FITZGERALD ENGINEERING LINGO
IEEE POWER ENGINEERING SOCIETY CHICAGO CHAPTER THE OKONITE COMPANY WEDNESDAY JANUARY 11, 2006 JIM FITZGERALD ENGINEERING LINGO WHEN YOU HEAR AN ENGINEER SAY A NUMBER OF DIFFERENT APPROACHES ARE BEING IMPLEMENTED
More informationDIVISION 26 - ELECTRICAL SECTION 26 05 20 CABLES FOR INSTRUMENTATION
DIVISION 26 - ELECTRICAL PART 1 - GENERAL 1.01 SUMMARY A. Section Includes 1. Instrumentation Cables 1.02 SUBMITTALS A. Submit in accordance with requirements of Section 01 33 00. B. Product Data: Submit
More informationC 060 CCTV Coaxial Cable
C 060 CCTV Coaxial Cable These cables are used for video transmissons of CCTV applications..4...... Coaxial Cable (C 060).. Inner Conductor : Ø 0.60 mm Bare Copper.. Insulation : Ø.80 mm Gas-injected Foam
More informationThe Handbook 2013 EDITION
The Handbook 2013 EDITION Trust Als you safe Alsecure is the cable you can stake your reputation on when safety and security are critical to maintain circuit integrity for mains power, lighting, alarms,
More informationFault location on power cables. Fault location on power cables
Fault location on power cables Fault location on power cables Contents: 1. Introduction 2. Construction of power cables 3. Cable faults 01. Introduction Fault location on communication and power cables
More informationKNOW YOUR OPTIONS: 69 KV XLPE POWER CABLE
Know Your Options: 69 kv XLPE Power Cable 3 material and size material is a matter of both customer preference and required current carrying capacity Copper conductor common for larger loads When both
More information100% EMI Emission Containment
100% EMI Emission Containment Designed for Longer Service Life Highly Flexible for Easier Handling and Faster Installation Authorized Distributor Industrial VFD Cables Index n Variable Frequency Drive
More informationGexol. Gexol. The Global Cable Solutions Company. Designed for safe, reliable performance in the harshest oil and gas operating environments
Gexol Gexol World Class World Class Designed for safe, reliable performance in the harshest oil and gas operating environments Power Control Instrument VFD The Global Cable Solutions Company Gexol World
More informationALARMLINE ANALOGUE Linear Heat Detection System
ALARMLINE ANALOGUE Alarmline Analogue sensor cable senses temperature variations by continuously monitoring the resistance of specially doped N.T.C. polymeric insulation. A change in temperature produces
More informationChemical resistance Accidental
Industrial flexible cable, insulation and outer sheath in elastomer Description Application TITANEX flexible cable is intended for installations with moving equipment, electric appliances and for building
More informationTECHNICAL SPECIFICATION FOR LOW-FREQUENCY CABLES AND WIRES WITH PVC INSULATION AND PVC SHEATH
Rev. 1:2007 TECHNICAL SPECIFICATION FOR LOW-FREQUENCY CABLES AND WIRES WITH PVC INSULATION AND PVC SHEATH Suruhanjaya Komunikasi dan Multimedia Malaysia Off Pesiaran Multimedia, 63000 Cyberjaya, Selangor
More information)454, !,5-).)5- #!",% 3(%!4(3 #/.3425#4)/. ).34!,,!4)/.!.$ 02/4%#4)/. /& #!",%3!.$ /4(%2 %,%-%.43 /& /543)$% 0,!.43. )454 Recommendation,
INTERNATIONAL TELECOMMUNICATION UNION )454, TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU #/.3425#4)/. ).34!,,!4)/.!.$ 02/4%#4)/. /& #!",%3!.$ /4(%2 %,%-%.43 /& /543)$% 0,!.43!,5-).)5- #!",% 3(%!4(3
More informationBRÖCKSKES D-VIERSEN PV1-F 4,0 mm BRÖCKSKES D-VIERSEN PV1-F 4,0 mm d d 2 2 C VDE-REG.-Nr. 8292 10/2009
d BRÖCKSKES BRÖCKSKES D-VIERSEN D-VIERSEN PV1-F PV1-F 4,0 mm 4,0 2 mm VDE-REG.-Nr. 2 C 8292 10/2009 s - THE COMPANY DIN EN ISO 9001 More than 60 years of experience in temperature measurement and control
More informationRF & Microwave cable assemblies C291
ERTIFIED C AS 9100 RF & Microwave cable assemblies C291 B CONTENTS Pages Introduction... B-4 Specify the right cable for your application... B-5 Finder guide cables vs insertion loss... B-6 to B-7 Flexible
More informationFlexible and safe solutions, for decades. Cables for alarmand safety systems
Flexible and safe solutions, for decades. Cables for alarmand safety systems 2 We offer the widest range of cables on the market for every kind of installation. It s all about reliability. It is always
More informationRutenbeck Network Connection Box Cat. 5, shielded. Cable installation. UAE Connection Box Cat. 5 Operating Instructions.
Rutenbeck Network Connection Box Cat. 5, shielded 1-gang, 1 x 8-pole Order No.: 0180 00 2-gang, 2 x 8-pole Order No.: 0178 00 1-gang, (especially for channel construction) Order No.: 0802 00 2-gang, (especially
More informationCIR. Index. Gexol. Standard CIR UL Listed Type TC-ER. Crush and Impact Resistant Without External Armoring. Arctic CIR UL Listed Type TC-ER-HL*
Gexol CIR Crush and Impact Resistant Without External Armoring Passes the same stringent crush and impact testing required by UL 2225 for Type MC-HL n Available in Standard and Arctic Grade Jackets n Highly
More informationRADOX railway cables acc. to EN 50264 and EN 50306. Edition 2009
RADO railway cables acc. to EN 50264 and EN 50306 Edition 2009 Bridging our know how Interdisciplinary knowledge The HUBER+SUHNER Group is a leading international manufacturer of electrical and optical
More informationCables, Cable Laying & Accessories Manual
Distribution Business Cables, Cable Laying & Accessories Manual Database ref: File Ref: Title Page & Revision Log For Cables & Access v4 - Nov 2003.doc Manual Name: Cables & Accessories Manual Version
More informationPVC YALITIMLI SÝNYAL VE KONTROL KABLOLARI PVC INSULATED SIGNAL AND CONTROL CABLES (VDE 0812-VDE 0814-VDE 0245)
LÝYY KABLO YAPISI: CONSTRUCTION: 1- ÝLETKEN : IEC-228 ;DIN VDE 0295;HD 383 SINIF-5 ELEKTROLÝTÝK BÜKÜLÜ BAKIR 2- YALITKAN : DIN VDE 0207 BÖLÜM-4 YI2 PVC KOMPAUND 3- YALITIM RENK : DIN 47100 4- BÜKÜM : UYGUN
More informationA cable for International Quality Standard
www.calendarkabel.com KAB I N T E R N A T I O N A L A cable for International Quality Standard COMMUNICATION CABLES MULTICORE CABLES Highly flexible Non Shielded Multicore Cable. Conforms to EU low-voltage
More informationCommercial Coaxial Cable
Commercial Coaxial Cable For the Best in COMMERCIAL TV Reception Solutions! Do you require a Digital TV reception system for your next project? Matchmaster can supply For The Best Design and supply of
More informationBETAtrans. Cables and Systems for Rolling Stock. Edition 2006
BETAtrans Cables and Systems for Rolling Stock. Edition 2006 Info Consulting and Sales By Phone To ask for Information or to place an order please use the following number: +49 (0)9172-6844-11 By Fax For
More informationThermocouple Wire & Cable
Thermocouple Wire & Cable TRM Ltd & MICC Ltd Temperature House 21 Sedling Road Wear Industrial Estate Washington Tyne & Wear NE38 9BZ PVC Extruded Example Applications: Permanent Sensor Fabrication, Laboratories,
More informationcoaxial cable coaxial Cable CERTIFIED 100% certified coaxial cable A cable that is marked Televés, no doubt is a certified cable
COAXIAL CABLE coaxial Cable 100% certified coaxial cable coaxial cable CERTIFIED The step ahead undertaken by Televés to improve its service and technical excellence, is now reflected in this new challenge.
More information450-750 VOLTS - Copper conductor PVC insulated SSA 1320, IEC 60227 & BS 6004 HO 7V - U With Solid Conductor - TYPE 60227 IEC 01. Insulation Thickness
450 50 VOLTS Copper conductor PVC insulated SSA 320, IEC 6022 & BS 6004 HO V U With Solid TYPE 6022 IEC 0 For internal wiring equipment rated voltage up to 000 V AC and up to 50 V to earth. Catalogue Number
More informationOPTICAL FIBER CABLES
OPTICAL FIBER CABLES CONTENTS INTRODUCTION QUALITY ASSURANCE RECOMMENDED ORDERING PARAMETERS GENERALITIES :. Advantage. General Description.. Construction.. Principle TYPICAL SPECIFICATIONS OF OPTICAL
More informationSCHEDULE ' A ' TECHNICAL SPECIFICATION FOR SINGLE CORE,UNARMOURED L.T.XLPE POWER CABLE FOR DISTRIBUTION NETWORK IN MAHARASHTRA
SCHEDULE ' A ' TECHNICAL SPECIFICATION FOR SINGLE CORE,UNARMOURED L.T.XLPE POWER CABLE FOR DISTRIBUTION NETWORK IN MAHARASHTRA (SPECIFICATION NO.MM/I/ 1 X C-UA- LTXLPE/2006) MAHARASHTRA STATE ELECTRICITY
More informationCoaxial Cables for Medium-Frequency Applications
Coaxial Cables for Medium-Frequency Applications Coaxial Cables for Medium-Frequency Applications Introduction Telecommunications technology is moving forward rapidly and the need for fast and reliable
More informationCHARACTERISTICS AND ADVANTAGES OF OPTICAL FIBER CABLES
AND ADVANTAGES OF OPTICAL FIBER CABLES ADVANTAGES Low attenuation. Long repeater spacings or repeaterless networks. Wide bandwidth. Large transmission capacity with simultaneous voice, data and video transmission
More information6 ELECTRICAL PARAMETERS
6 ELECTRICAL PARAMETERS For power, low voltage and medium voltage cables, cross section nominal areas are calculated in taking into account several parameters as: permissible current carrying capacities
More informationFLEXIBLE INDUSTRIAL CABLES H07RN-F TENAFLEX SR
FLEXIBLE INDUSTRIAL CABLES H07RN-F TENAFLEX SR Standards : CENELEC HD 22.4 NF C 32-102-4 DIN VDE 0282-1 and VDE 0282-4 BS 6007 and BS 6500 IEC 60245-4 Rated voltage Rated voltage: 450/750 V (Use up to
More informationLOW LOSS CABLE PAG. 1
LOW LOSS CABLE PAG. 1 INTRODUCTION Following many requests we received regarding the need for low-loss custom cable assemblies, we have set up a special production of high performance coaxial cable assemblies
More informationCABLE SPECIFICATION CAN CAB RJ45-SUBD9
CABLE SPECIFICATION All technical information contained in this document is the exclusive property of STI and may neither be used nor disclosed without its prior written consent. AAV 33801 1/8 Connector
More informationIMVIB. Online vibration monitoring for Ariel compressors
IMVIB Online vibration monitoring for Ariel compressors The cost-effective way to add spectral vibration measurement & trending on critical machinery Monitoring vibration trends of your industrial equipment
More informationPROFIBUS cable. PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications
Data Sheet 10/63-6.47-EN Rev. D PROFIBUS cable PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications PROFIBUS PA cables Non-Ex (Hazardous) applications Ex (Hazardous) applications
More informationHARTING Ethernet Cabling 8-poles Overview
Ethernet Cabling 8-poles Overview RJ45 Connectors [on page 8] System cables [on page 12] Distribution modules and Outlets [on page 17] Connectors [on page 20] System cables [on page 26] Panel feed-throughs
More informationFlexible cables for submersible products
Flexible cables for submersible products Standards SUBCAB cables complies with the following general standards: IEC 6045 (general) IEC 608 class 5 (conductor) IEC 608-- CLAUSE 9 (oil resistant) IEC 608--
More informationThe Quality Connection. Cables for Data Transmission in Industrial Automation
The Quality Connection Cables for Data Transmission in Industrial Automation Product range Instrumentation- and control cables Thermocouple extension and compensating cables Power cables (low and medium
More information