International Electrotechnical Commission Standards
|
|
|
- Marjorie Francis
- 9 years ago
- Views:
Transcription
1 International Electrotechnical Commission Standards Standard IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC International standard of resistance for copper IEC standard voltages International electrotechnical vocabulary. Chapter 461: Electric Paper insulated metal sheathed for rated voltages up to 18/30kV (with copper or aluminium conductors and excluding gas pressure and oil-filled ) Part 1: tests on and their accessories Paper insulated metal sheathed for rated voltages up to 18/30kV (with copper or aluminium conductors and excluding gas pressure and oil-filled ) Part 2: general and construction requirements Electrical installations in ships Part 101: definitions and general requirements Electrical installations in ships - Part 350: shipboard power - general construction and test requirements Electrical installations in ships - Part 351: insulating materials for shipboard and offshore units, power, control, instrumentation, telecommunication and data Electrical installations in ships - Part 352: choice and installation of electrical Electrical installations in ships - Part 353: single and multicore non-radial power with extruded solid insulation for rated voltages 1kV and 3kV Electrical installations in ships - Part 354: single and 3 core power with extruded solid insulation for rated voltages 6kV up to 30kV Electrical installations in ships - Part 359: sheathing materials for shipboard power and telecommunication Electrical installations in ships. Shipboard telecommunication and radio-frequency. Shipboard flexible coaxial Electrical installations in ships. Shipboard telecommunication and radio-frequency. Telephone for non-essential communication services Electrical installations in ships. Shipboard telecommunication and radio-frequency. General instrumentation, control and communication Electrical installations in ships - Part 376: for control and instrumentation circuits 150/250V Radio frequency Part 0: guide to the design of detailed specifications. Section one: coaxial Radio frequency Part 1: general requirements and measuring methods Radio frequency Part 2: relevant cable specifications Radio frequency Part 3: general requirementsand tests for single-unit coaxial for use in cabled distribution systems Radio frequency Part 4: specification for superscreened Section1: general requirements and test methods Tests of oil-filled and gas-pressure and their accessories - Part 1: oil-filled, paper or polypropylene paper laminate insulated, metal-sheathed and accessoires for alternating voltages up to and including 500kV Tests of oil-filled and gas-pressure and their accessories - Part 2: internal gas-pressure and accessories for alternating voltages up to 275kV Radio-frequency connectors. Part 10: RF coaxial connectors with inner diameter of outer conductor 3mm with snap-on coupling. Characteristic impedance 50 ohms Radio-frequency connectors. Part 11: RF coaxial connectors with inner diameter of outer conductor 9.5mm with screw coupling. Characteristic impedance 50 ohms Radio-frequency connectors. Part 13: RF coaxial connectors with inner diameter of outer conductor 5.6mm. Characteristic impedance 75 ohms
2 IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC Radio-frequency connectors. Part 14: RF coaxial connectors with inner diameter of outer conductor 5.6mm. Characteristic impedance 75 ohms Radio-frequency connectors. Part 15: RF coaxial connectors with inner diameter of outer conductor 4.13mm with screw coupling. Characteristic impedance 50 ohms Radio-frequency connectors. Part 17: RF coaxial connectors with inner diameter of outer conductor 6.5mm with screw coupling. Characteristic impedance 50 ohms Radio-frequency connectors. Part 18: RF coaxial connectors with inner diameter of outer conductor 2.79mm with screw coupling. Characteristic impedance 50 ohms Radio-frequency connectors. Part 19: RF coaxial connectors with inner diameter of outer conductor 2.08mm with snap coupling. Characteristic impedance 50 ohms Radio-frequency connectors. Part 20: RF coaxial connectors with inner diameter of outer conductor 2.08mm with screw coupling. Characteristic impedance 50 ohms Radio-frequency connectors. Part 21: Two types of radio-frequency connectors with inner diameter of outer conductor 9.5mm with different versions of screw coupling. Characteristic impedance 50 ohms Radio-frequency connectors. Part 22: RF two-pole bayonet coupled connectors for use with shielded balanced having twin inner conductors Radio-frequency connectors. Part 24: RF coaxial connectors with screw coupling, typically for use in 75 ohm cable distribution systems (type F) Radio-frequency connectors. Part 26: RF coaxial connectors with screw coupling. Characteristic impedance 50 ohms Radio-frequency connectors. Part 27: RF coaxial connectors with screw coupling, typically for use in 75ohm cable distribution systems (Type E) Radio-frequency connectors. Part 28: RF coaxial connectors with inner diameter of outer conductor 6.5mm with snap coupling. Characteristic impedance 75 ohms Colours of the cores of flexible and cores Guide to the selection of high-voltage Low-frequency and wires with PVC insulation and PVC sheath Part 1: general test and measuring methods Low-frequency and wires with PVC insulation and PVC sheath Part 2: in pairs, triples, quads and quintuples for inside installations Low-frequency and wires with PVC insulation and PVC sheath Part 3: equipment wires with solid or stranded conductor, PVC insulated in singles, pairs and triples Conductors of insulated Test on cable oversheaths which have a special protective function and are applied by extrusion Impulse tests on and their accessories Rubber insulated - rated voltages up to and including 450/750 V Part 1: general requirements Rubber insulated - rated voltages up to and including 450/750 V Part 2: test methods Rubber insulated - rated voltages up to and including 450/750 V Part 3: heat resistant silicone insulated Rubber insulated - rated voltages up to and including 450/750 V Part 4: cords and flexible Rubber insulated - rated voltages up to and including 450/750 V Part 5: lift Rubber insulated - rated voltages up to and including 450/750 V Part 6: arc welding electrode Rubber insulated - rated voltages up to and including 450/750 V Part 7: heat resistant ethylene-vinyl acetate rubber Rubber insulated - rated voltages up to and including 450/750 V Part 8: cords for applications requiring high flexibility Polyvinyl chloride insulated for rated voltages up to and including 450/750 V Part 1: general reqiurements Polyvinyl chloride insulated for rated voltages up to and including 450/750 V Part 2: test methods Polyvinyl chloride insulated for rated voltages up to and including 450/750 V Part 3: nonsheathed for fixed wiring Polyvinyl chloride insulated for rated voltages up to and including 450/750 V Part 4: sheathed for fixed wiring
3 IEC IEC IEC IEC IEC IEC IEC IEC Polyvinyl chloride insulated for rated voltages up to and including 450/750 V Part 5: flexible Polyvinyl chloride insulated for rated voltages up to and including 450/750 V Part 6: lift and for flexible connections Polyvinyl chloride insulated for rated voltages up to and including 450/750 V Part 7: flexible screened and unscreened with two or more conductors Electrical conductors of insulated cable Electric - calculation of the current rating - Part 1: current rating equations (100% load factor) and calculation of losses - Section 1:general Electric - calculation of the current rating - Part 1: current rating equations (100% load factor) and calculation of losses -Section 2:sheath eddy current loss factors for two circuits in flat formation Electric - calculation of the current rating - Part 1: current rating equations (100% load factor) and calculation of losses -Section 3:current sharing between parallel single-core and calculation of circulating current losses Electric - calculation of the current rating - Part 2: thermal resistance -Section 1:calculation of thermal resistance IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC Electric - calculation of the current rating - Part 2: thermal resistance -Section 2:a method for calculating reduction factors for groups of in free air, protected from solar radiation Electric - calculation of the current rating - Part 3: sections on operating conditions - Section1:reference operating conditions and selection of cable type Electric - calculation of the current rating - Part 3: sections on operating conditions - Section2:economic optimisation of power cable size Standard colours for insulation for low-frequency and wires Tests for electric under fire conditions - circuit integrity - Part 11: apparatus - fire alone at a flame temperature of at least 750 deg C Tests for electric under fire conditions - circuit integrity - Part 12: apparatus - fire with shock at a temperature of at least 830 deg C Tests for electric under fire conditions - circuit integrity - Part 21: procedures and requirements - of rated voltage up to and including 0.6/1.0kV Tests for electric under fire conditions - circuit integrity - Part 23: procedures and requirements - electric data Tests for electric under fire conditions - circuit integrity - Part 25: procedures and requirements - optical fibre Tests for electric under fire conditions - circuit integrity - Part 31: procedures and requirements for fire with shock - of rated voltage up to and including 0.6/1.0kV Tests on electric and optical fibre under fire conditions Part 1: test for vertical flame propagation for a single insulated wire or cable Section 1: apparatus IEC Tests on electric and optical fibre under fire conditions Part 1: test for vertical flame propagation for a single insulated wire or cable Section 2: procedure for 1kW pre-mixed flame Tests on electric and optical fibre under fire conditions Part 1: test for vertical flame IEC propagation for a single insulated wire or cable Section 3: procedure for determination of flaming droplets/particles IEC Tests on electric and optical fibre under fire conditions Part 2: test for vertical flame propagation for a single small insulated wire or cable Section 1: apparatus IEC Tests on electric and optical fibre under fire conditions Part 2: test for vertical flame propagation for a single small insulated wire or cable Section 2: procedure for diffusion flame IEC bunched wires or Section 10: apparatus IEC bunched wires or Section 21: category A F/R IEC bunched wires or Section 22: category A IEC bunched wires or Section 23: category B IEC bunched wires or Section 24 category C IEC bunched wires or Section 25 category D
4 IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC Guide to the calculation of resistance of plain and coated copper conductors of low-frequency and wires Insulating materials based on mica Part 3: specifications for individual materials Section 8: mica paper tapes for flame-resistant security Power with extruded insulation and their accessories for rated voltages from 1kV to 30kV Part 1: for rated voltages of 1kV and 3kV Power with extruded insulation and their accessories for rated voltages from 1kV to 30kV Part 2: for rated voltages from 6kV up to 30kV Power with extruded insulation and their accessories for rated voltages from 1kV to 30kV Part 4:test requirements on accessories for with rated voltages from 6kV up to 30kV Thermocouples. Part 3: extension and compensating - tolerances and identification system Mineral insulated and their terminations with a rated voltage not exceeding 750V Part 1: Mineral insulated and their terminations with a rated voltage not exceeding 750V Part 2: terminations Low-frequency with polyolefin insulation and moisture barrier polyolefin sheath Calculation of the lower and upper limits for the average outer dimensions of with circular copper conductors and of rated voltages up to and including 450/750V Short-circuit temperature limits of electric with rated voltages of 1kV and 3kV Test on gases evolved during combustion of materials from. Part 1:determination of the amount of halogen acid gas Test on gases evolved during combustion of materials from. Part 2:determination of the degree of acidity of gases evolved during the combustion of materials taken from electric by measuring ph and conductivity Optical fibres. Part 1: measurement methods and test procedures. Section 1: general & guidance Optical fibres. Part 1: measurement methods and test procedures. Section 20: fibre geometry Optical fibres. Part 1: measurement methods and test procedures. Section 21: coating geometry Optical fibres. Part 1: measurement methods and test procedures. Section 22: length measurement Optical fibres. Part 1: measurement methods and test procedures. Section 30: fibre proof test Optical fibres. Part 1: measurement methods and test procedures. Section 31: tensile strength Optical fibres. Part 1: measurement methods and test procedures. Section 32: coating strippability Optical fibres. Part 1: measurement methods and test procedures. Section 33: stress corrosion susceptibility Optical fibres. Part 1: measurement methods and test procedures. Section 34: fibre curl Optical fibres. Part 1: measurement methods and test procedures. Section 40: attenuation Optical fibres. Part 1: measurement methods and test procedures. Section 41: bandwidth Optical fibres. Part 1: measurement methods and test procedures. Section 42: chromatic dispersion Optical fibres. Part 1: measurement methods and test procedures. Section 43: numerical aperture Optical fibres. Part 1: measurement methods and test procedures. Section 44: cutt-off wavelength Optical fibres. Part 1: measurement methods and test procedures. Section 45: mode field diameter Optical fibres. Part 1: measurement methods and test procedures. Section 46: monitoring of changes in optical transmittance IEC Optical fibres. Part 1: measurement methods and test procedures. Section 47: macrobending loss IEC Optical fibres. Part 1: measurement methods and test procedures. Section 46: polarisation mode dispersion IEC Optical fibres. Part 1: measurement methods and test procedures. Section 49: differential mode delay IEC Optical fibres. Part 1: measurement methods and test procedures. Section 50: damp heat IEC Optical fibres. Part 1: measurement methods and test procedures. Section 51: dry heat IEC Optical fibres. Part 1: measurement methods and test procedures. Section 52: change of temperautre
5 IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC Optical fibres. Part 1: measurement methods and test procedures. Section 53: water immersion Optical fibres. Part 1: measurement methods and test procedures. Section 54: gamma irradiation Optical fibres. Part 2: product specifications - general Optical fibre Part 1: generic specification Section 1: general Optical fibre Part 1: generic specification Section 2: basic optical cable test procedures Optical fibre. Part 2: Indoor Section 10:sectional specification Optical fibre. Part 2: Indoor Section 11:detailed specification for simplex and duplex for use in premises cabling Optical fibre. Part 2: Indoor Section 21:detailed specification for multi-fibre optical distribution for use in premises cabling Optical fibre. Part 3: sectional specification - outdoor Optical fibre. Part 3: sectional specification - outdoor Section 10: family specification for duct and directly buried optical telecommunication Optical fibre. Part 3: sectional specification - outdoor Section 12: detailed specification for duct and directly buried optical telecommunication for use in premises cabling Part 1: methods for general application Section 1:measurement of thickness and overall dimensions - tests for determining the mechanical properties Part 1: methods for general application Section 2: thermal ageing methods Part 1: methods for general application Section 3:methods for determining the density - water absorption tests - shrinkage test Part 1: methods for general application Section 4: test at low temperature Part 2: methods specific to elastomeric compounds Section 1:ozone resistance, hot set and mineral oil immersion tests Common test methods for insulating and sheathing materials of electric. Part 3: methods specific to PVC compounds Section 1:pressure test at high temperature - tests for resistance to cracking Common test methods for insulating and sheathing materials of electric. Part 3: methods specific to PVC compounds Section 2:loss of mass test - thermal stability test Common test methods for insulating and sheathing materials of electric and optical. Part 4: methods specific to polyethylene and polypropylene compounds Section 1: resistance to environmental stress cracking - measurement of the melt flow index, carbon black and/or mineral filler content measurement in polyethylene by direct combustion - measurement of carbon black content by thermogravimetric analysis Common test methods for insulating and sheathing materials of electric and optical. Part 4: methods specific to polyethylene and polypropylene compounds Section 2: tensile strength and elongation at break after conditioning at elevated temperature - wrapping test after conditioning at elevated temperature - wrapping test after thermal ageing in air - measurement of mass increase - long-term stability test - test method for copper-catalyzed oxidative degradation Common test methods for insulating and sheathing materials of electric and optical. Part 5: methods specific to filling compounds Section 1: drop-point - separation of oil -lower temperature brittleness - total acid number - absence of corrosive components Power with extruded insulation and their accessories for rated voltages above 30kV up to 150kV- test methods and requirements Connectors for optical fibres and. Part 1: generic specification Electrical test methods for electric. Part 1: electrical test for, cords and wires for voltages up to and including 450/750V Electrical test methods for electric. Part 2: partial discharge tests Electrical test methods for electric. Part 3: test methods for partial discharge measurements on lengths of extruded power Zinc-coated steel wires for stranded conductors Hard-drawn aluminium wire for overhead line conductors Radio frequency and coaxial cable assemblies. Part 1: generic specification - general requirements and test methods
6 IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC/TR 6222 ISO/IEC ISO/IEC ISO/IEC ISO/IEC ISO/IEC ISO/IEC/TR ISO/IEC/TR Radio frequency and coaxial cable assemblies. Part 2: sectional specification for flexible coaxial cable assemblies Arc welding equipment. Part 12: coupling devices for welding Measurement of smoke density of burning under defined conditions Part 1: test apparatus Measurement of smoke density of burning under defined conditions Part 2: test procedure and requirements Mechanical splices and fusion splice protectors for optical fibres and Part 1: generic specification Cable trunking and ducting systems for electrical installations Part 1: general requirements Cable trunking and ducting systems for electrical installations Part 2: particular requirements Section 1: cable trunking and ducting systems intended for mounting on walls or ceilings systems Part 1: overview and guidance systems Part 2: physical layer specification and service definition systems Part 3: data link service definition systems Part 4: data link protocol systems Part 5: application layer service definition systems Part : application layer protocol specification Test methods for accessories for power with rated voltage from 6kV up to 30kV Cable tray systems and cable ladder systems for cable management Testing of balanced communication cabling in accordance with ISO/IEC Part 1: installed cabling Testing of balanced communication cabling in accordance with ISO/IEC Part 2: patch cords and work area cords Fire performance of communication installed in buildings Information technology - generic cabling for customer premises Information technology - configuration of customer premises cabling for applications Part 1: Integrated Services Digital Network (ISDN) basic access Information technology - configuration of customer premises cabling for applications Part 2: Integrated Services Digital Network (ISDN) primary rate Information technology - implementation and operation of customer premises cabling Part 1: administration Information technology - generic cabling for homes Information technology - implementation and operation of customer premises cabling Part 2: planning and installation Information technology - implementation and operation of customer premises cabling Part 3: testing of optical fibre cabling NEK 606 EEMUA 133 SIWO-KUL Cables for offshore installation halogen-free or mud resistant Specification for underground armoured cable protected against solvent penetration and corrosive attack Silicone single core cable with overall polyester braid
INTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 60502-1 Second edition 2004-04 Power cables with extruded insulation and their accessories for rated voltages from 1 kv (U m = 1,2 kv) up to 30 kv (U m = 36 kv) Part 1: Cables
British Standards BSEN 3475-513:2005
s British Standard BS 91:1998 BS 215:1970 BS 638-4:1996 BS 1990-1:1984 BSEN 3475-100:2002 BSEN 3475-201:2002 BSEN 3475-301:2002 BSEN 3475-302:2002 BSEN 3475-303:2002 BSEN 3475-305:2002 BSEN 3475-306:2005
INTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 61156-5 First edition 2002-03 Multicore and symmetrical pair/quad cables for digital communications Part 5: Symmetrical pair/quad cables with transmission characteristics up
R=Required by Lab S=May be subcontracted IEC SYSTEM FOR CONFORMITY TESTING AND CERTIFICATION OF ELECTRICAL EQUIPMENT COMMITTEE OF TESTING LABORATORIES
IEC SYSTEM FO CONFOMITY TESTING AND CETIFICATION OF ELECTICAL EQUIPMENT COMMITTEE OF TESTING LABOATOIES TESTING AND MEASUING EQUIPMENT/ALLOWED SUBCONTACTING Power cables with extruded insulation and their
Offshore Transformer Platform. Technical Standard. Energinet.dk. HV, MV, LV and Signal Cables and Cable Routing
Offshore Transformer Platform Technical Standard Energinet.dk HV, MV, LV and Signal Cables and Cable Routing ETS - 03 Rev. 1 Acadre doc. 44858-09 Revision survey Chpt. Description Revision Date Resp. -
The Quality Connection. BETAflam Fire Resistant Safety Cables
The Quality Connection BETAflam Fire Resistant Safety Cables 2 Contact Consulting and sales Switzerland Phone +41 (0)62 288 82 82 Fax +41 (0)62 288 83 83 [email protected] www.leoni-infrastructure-datacom.com
Global cable expertise for rolling stock
Global cable expertise for rolling stock Global cable expertise for rolling stock Single and multicore Low voltage control cables Jumper cables HV roof cables (25 kv) rubber cables for power needs of locomotives
FIRE RESISTANT CABLE CONSTRUCTION OF CABLES
FIRE RESISTANT CABLE In all fire disasters, fire smoke, heat and toxic fumes are the main obstacles to safe evacuation of a building or area. A major contribution towards overcoming these hazards is the
3.6/6 kv XLPE insulated cables 5. 6/10 kv XLPE insulated cables 15. 8.7/15 kv XLPE insulated cables 25. 12/20 kv XLPE insulated cables 35
CONTENTS INTRODUCTION 1 Cable selection, cable specification, cable services CABLES Constructional data: 3.6/6 kv XLPE insulated cables 5 SECTION 1 6/10 kv XLPE insulated cables 15 SECTION 2 8.7/15 kv
Removal of EP 20 10 00 02 SP High Voltage Cable
TN 018: 2014 Technical Note For queries regarding this document [email protected] www.asa.transport.nsw.gov.au TN 018: 2014 Issued date 12 March 2014 Effective dates 12 March 2014 Subject:
TECHNICAL SPECIFICATION FOR LOW-FREQUENCY CABLES AND WIRES WITH PVC INSULATION AND PVC SHEATH
Rev. 1:2007 TECHNICAL SPECIFICATION FOR LOW-FREQUENCY CABLES AND WIRES WITH PVC INSULATION AND PVC SHEATH Suruhanjaya Komunikasi dan Multimedia Malaysia Off Pesiaran Multimedia, 63000 Cyberjaya, Selangor
Communication, Signal & Data Cables
Communication, Signal & Data Cables Used for indoor installation and interconnection of transmission, telephone, telegraph and electronic equipment as well as media equipments www.alfanar.com Communication
KNOW YOUR OPTIONS: 230 KV POWER CABLES
KNOW YOUR OPTIONS: 230 KV POWER CABLES 71 CONDUCTOR MATERIAL AND SIZE Conductor material is a matter of both customer preference and required current carrying capacity At 230 kv, copper is most common
4 IX D N E P P A Installation methods Current-carrying capacity and voltage drop for cables Reference method IET Wiring Matters
8 Appendix 4 of BS 7671 by Mark Coles Appendix 4, Current-carrying capacity and voltage drop for cables and flexible cords, has seen significant changes with the publishing of BS 7671:2008. This article
ScottishPower Distribution Cables & Equipment. Metal Theft
ScottishPower Distribution Cables & Equipment Metal Theft April 2012 As an aid to deterring to metal theft this booklet has been put together to help identify the types of utility power cables and associated
Section 5 161 kv Power Cables
Know Your Options: 161 kv Power Cable 61 material and size material is a matter of both customer preference and required current carrying capacity Copper conductor common for larger loads When both copper
UGVCL/SP/591/11KV HT AB CABLE
TECHNICAL SPECIFICATION FOR 11KV AERIAL BUNCHED CABLES FOR OVERHEAD LINES (CROSSED LINKED POLYTHENE DRY GAS CURED) 1. SCOPE This specification covers requirements of XLPE insulated, 11 KV Aerial Bunched
FOREWORD ONE OF THE WORLD S BIGGEST COMPANIES IN THE SECTOR.
OFFSHORE CABLES FOREWORD ONE OF THE WORLD S BIGGEST COMPANIES IN THE SECTOR. General Cable Corporation is one of the world s leading cable manufacturing companies. In its work it has contributed decisively
B05: Cable protection and sheathing
SHEATHING MATERIALS MDPE, BLACK This is the standard sheathing material for cables for outdoor use. The material is UV stabilised with using 2.5 ± 0.5 % carbon black. It has excellent weathering resistance.
Outside Telephone Cable
Outside Telephone Cable Filled Core. Moisture Barrier. Description Soft copper wires insulated with high density polyethylene, foam skin or solid. Filled core, conformed by groups of pairs or by unit of
108-93018 05 APR 2016 Rev M
Product Specification 108-93018 05 APR 2016 Rev M Copper LAN Cable 1. SCOPE 1.1. Content This specification describes the general requirements for CommScope copper LAN cable. 2. APPLICABLE DOCUMENTS The
PROFIBUS cable. PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications
Data Sheet 10/63-6.47-EN Rev. D PROFIBUS cable PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications PROFIBUS PA cables Non-Ex (Hazardous) applications Ex (Hazardous) applications
Corporate Profile ROYAL. MODERN ROYAL ELECTRIC Ideal Power Solution MRE ELECTRICAL, INSTRUMENTATION & COMMUNICATION SYSTEMS
Corporate Profile MODERN ROYAL ELECTRIC Ideal Power Solution ROYAL MRE ELECTRICAL, INSTRUMENTATION & COMMUNICATION SYSTEMS MAJOR STOCKIST >>> CATHODIC PROTECTION CABLES >>> LOW VOLTAGE CABLES >>> MEDIUM
Aerial Fibre Optics. Complete One Stop Solution for Aerial Fibre Optics. OPGW Cable and Fittings for OPGW
Complete One Stop Solution for OPGW Cable and Fittings for OPGW 53, Justice Chandra Madhav Road, Kolkata - 700020. India. Phone: 91-33-24748575 / 7565 Fax: 91-33-2476-1955 Email: [email protected] Website:
KNOW YOUR OPTIONS: 69 KV XLPE POWER CABLE
Know Your Options: 69 kv XLPE Power Cable 3 material and size material is a matter of both customer preference and required current carrying capacity Copper conductor common for larger loads When both
COAX Cables Radio Frequency Cables
COAX Cables Radio Frequency Cables Contents Page Table of contents Pictographs General information Introduction Types and abbreviations Temparature range Construction Characteristics Special constructions
Fire Resistant Cables
109/4 Fire Resistant Cables SR 114H Standard - SR 114E Enhanced BS 5839-1 BS 7629-1 BS 6387 BS 8434-1/2 BS 6425 BS 7622 EN 50200 World-wide recognized high quality cables Firecel SR114 are used in: Data
Fault location on power cables. Fault location on power cables
Fault location on power cables Fault location on power cables Contents: 1. Introduction 2. Construction of power cables 3. Cable faults 01. Introduction Fault location on communication and power cables
INTERNATIONAL TELECOMMUNICATION UNION #/.3425#4)/. ).34!,,!4)/.!.$ 02/4%#4)/. /& #!",%3!.$ /4(%2 %,%-%.43 /& /543)$% 0,!.43
INTERNATIONAL TELECOMMUNICATION UNION )454, TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU #/.3425#4)/. ).34!,,!4)/.!.$ 02/4%#4)/. /& #!",%3!.$ /4(%2 %,%-%.43 /& /543)$% 0,!.43 /04)#!, &)"2% #!",%3 &/2
Festoon 715 P PUR cable for flexible application in festoon systems
CABLES FOR CRANE AND CONVEYOR APPLICATIONS Festoon 715 P PUR cable for flexible application in festoon systems S AB BRÖCKSKES D-VIERSEN Festoon 715 P 1 x 16.0 mm 2 C Marking for Festoon 715 P 07150162:
IEEE POWER ENGINEERING SOCIETY CHICAGO CHAPTER THE OKONITE COMPANY WEDNESDAY JANUARY 11, 2006 JIM FITZGERALD ENGINEERING LINGO
IEEE POWER ENGINEERING SOCIETY CHICAGO CHAPTER THE OKONITE COMPANY WEDNESDAY JANUARY 11, 2006 JIM FITZGERALD ENGINEERING LINGO WHEN YOU HEAR AN ENGINEER SAY A NUMBER OF DIFFERENT APPROACHES ARE BEING IMPLEMENTED
INTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 60227-1 Edition 2.2 1998-03 Edition 2:1993 consolidated with amendments 1:1995 and 2:1997 Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V
BETAtrans. Cables and Systems for Rolling Stock. Edition 2006
BETAtrans Cables and Systems for Rolling Stock. Edition 2006 Info Consulting and Sales By Phone To ask for Information or to place an order please use the following number: +49 (0)9172-6844-11 By Fax For
Fibre optic cables MDIC LSZH
MDIC LSZH MDIC LSZH - Indoor Access Cable. Micro Drop Installation Cable, special Access cable with low bend radius, no waterpeak G.657.A fibres. Ruggedized construction with excellent performance, easy
RADOX railway cables acc. to EN 50264 and EN 50306. Edition 2009
RADO railway cables acc. to EN 50264 and EN 50306 Edition 2009 Bridging our know how Interdisciplinary knowledge The HUBER+SUHNER Group is a leading international manufacturer of electrical and optical
HINDUSTAN PETROLEUM CORPORATION LIMITED ENGINEERING & PROJECTS GRESHAM ASSURANCE HOUSE, 2 ND FLOOR, A-1595(3) 1-A, SIR P M ROAD, FORT MUMBAI-400 001
NEW POL DEPOT AT HINDUSTAN PETROLEUM CORPORATION LIMITED ENGINEERING & S GRESHAM ASSURANCE HOUSE, 2 ND FLOOR, A-1595(3) 1-A, SIR P M ROAD, FORT MUMBAI-400 001 TECHNICAL SPECIFICATION OF XLPE, FRLS LT CABLES
Power and Wiring Cables
1 Single-Core PVC 1X...................... 1: Single-Core PVC/PVC 1Y.................. 1: Flat Twin & Flat Three Core PVC /Y........ 1: Multicore XLPE/LSF/SWA/LSF BS Control Cable.............................
PROFIBUS cable. for PROFIBUS-PA and -DP 10/63-6.46 EN
for PROFIBUS-PA and -DP 10/63-6.46 EN CPN 080/CPE 080-Ex PROFIBUS-PA basis cable AWG 18, 0.88 mm 2 Use For fixed installation indoor and outdoor, on racks and in conduits. Application Fieldbus cable for
High Voltage Systems. Today. The history of cables
High Voltage Cables High Voltage Systems Today Prysmian Cables and Systems B.V. is part of the Prysmian Group, a leading player in the industry of high-technology cables and systems for energy and telecommunications,
VIPERFLEX ELECTRIC CABLE
VIPERFLEX Flexible Low Voltage Electric Cable - 0.6/1kV (Rubber insulated) H07 RN-F & H07 BN-F Single Core 2-Core 2-Core and Earth 3-Core and Earth 4-Core and Earth Multi-Core and Earth H07 RCN-F & H07
Fire Performance Standard
Fire Performance Standard At present, in cable industry, Fire Retardant, Low Smoke Halogen Free (LSZH), Low Smoke Fume (LSF) and Fire Resistant cables are all described as Fire survival Cables. Flame Retardant
CHARACTERISTICS AND ADVANTAGES OF OPTICAL FIBER CABLES
AND ADVANTAGES OF OPTICAL FIBER CABLES ADVANTAGES Low attenuation. Long repeater spacings or repeaterless networks. Wide bandwidth. Large transmission capacity with simultaneous voice, data and video transmission
Uniprise Solutions COAX 101. White Paper. www.commscope.com
Uniprise Solutions COAX 101 White Paper www.commscope.com Structured cable systems have very thorough standards for fiber optic and twisted pair installations. The cabling components and installed systems
Specializing in the cable business for over 38 years, PT. SUPREME CABLE
Specializing in the cable business for over 38 years, PT. SUPREME CABLE MANUFACTURING & COMMERCE Tbk. (PT. SUCACO Tbk) has grown steadly to become a largest and leading cable manufacturer, with international
Flexible and safe solutions, for decades. Cables for alarmand safety systems
Flexible and safe solutions, for decades. Cables for alarmand safety systems 2 We offer the widest range of cables on the market for every kind of installation. It s all about reliability. It is always
T A B L E T 1 T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A
T A B L E T 1 1 of 7 Tests & Inspection Cable PCUT & PCUT-A (Table T1) T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A No. Test Scale MOC Requirements G 20:10:001:01 Defined Test
LEAD FREE FIREX. Interlock Armored Cables TECK90 and MC Industrial Cables. w w w. n e x a n s e n e r g y. c o m
FIREX Interlock Armored Cables TECK90 and MC Industrial Cables LEAD FREE O V E R 1 8 0 Y E A R S O F E X P E R I E N C E 866-663-9267 w w w. n e x a n s e n e r g y. c o m Interlock Armored Cables Introduction....2
CABLE 101. The Basics of Wire & Cable. Copyright 2007, Belden Inc.
CABLE 101 The Basics of Wire & Cable Copyright 2007, Belden Inc. KEY TERMS Insulations Jacket Capacitance Attenuation Velocity of propagation Dielectric strength Dielectric constant Working voltage Elongation
CAVEL VS80205 MADE IN ITALY 1000 V
0,05 9,00 x 7,20 (Pet) (LSZH) Attached CE01 CE02 Sheath Colour black black red Non-migrating Polyester tape longitudinally overlapped (Pet) 25 x 23 µm Outer sheath of Thermoplastic material - black - halogen-free,
)454, !,5-).)5- #!",% 3(%!4(3 #/.3425#4)/. ).34!,,!4)/.!.$ 02/4%#4)/. /& #!",%3!.$ /4(%2 %,%-%.43 /& /543)$% 0,!.43. )454 Recommendation,
INTERNATIONAL TELECOMMUNICATION UNION )454, TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU #/.3425#4)/. ).34!,,!4)/.!.$ 02/4%#4)/. /& #!",%3!.$ /4(%2 %,%-%.43 /& /543)$% 0,!.43!,5-).)5- #!",% 3(%!4(3
WHITE PAPER Fire & safety performance standards
WHITE PAPER Fire & safety performance standards Terminologies describing Fire Performance Terminologies describing Fire Performance often present a challenge to understand as how they apply to a cable
Optical Fibers Fiber Optic Cables Indoor/Outdoor
presents Optical Fibers Fiber Optic Cables Indoor/Outdoor Content Optical fiber function, types optical effects applications production of optical fibre Cable - general types Indoor Indoor / outdoor Outdoor
CONFLEX ELECTRIC CABLE
CONFLEX ELECTRIC CABLE CONFLEX - 0.6/1kV Flexible VSD/EMC Cables Applications WW VSD/EMC cables are manufactured for use where electrical interference distorts signal transmission in electric motors. Standard
Screened cable and data cable segregation
December 2007 Screened cable and data cable segregation Can an armoured power cable be considered a screened cable and how does this relate to power and data cable segregation? The short answer is yes;
ACCESSORIES FOR HV CABLES WITH EXTRUDED INSULATION
ACCESSORIES FOR HV CABLES WITH EXTRUDED INSULATION Ref: WG 21.06 (TB 177) JTF 21.15 (TB 210) TF B1.10 (Electra 212) Henk Geene Presentation overview Accessories function Accessory design Accessory types
MEDIUM VOLTAGE CABLES Up to and including 36 KV
MEDIUM VOLTAGE CABLES Up to and including 6 KV NOTICE As this catalogue is not intendedto cover all of LIBAN CABLES SAL possibilities in special cables manufacturing, the hereafter listing of the types
Gulf Cable & Electrical Ind. Co.
CONTENTS INTRODUCTION PRODUCT RANGE I PRODUCT DATA TABLES Irrigation 1 Coaxial s for T.V/ Satellite Antenna etc 2 Data Transmission s - 4 pair 24 AWG 3 TELEPHONE CABLES Telephone cables CCP-LAP & CCP-LAP-SS
David O Brien, CMP Products ([email protected])
David O Brien, CMP Products ([email protected]) 1) Main Function of Cable Glands 2) Common Issues with Cable Glands 3) Compliance / Standards, changing times 4) How do we select Cable Glands?
RoHS DATA, COAXIAL AND ELECTRONIC M.R. D A TA, C O A X I A L, ECOLGICAL Telecom Cables A N D EL E CTRON I C. Cables
RoHS DATA, COAXIAL AND ELECTRONIC D A TA, C O A X I A L, A N D EL E CTRON I C Cables Index SOLID MULTI-CONDUCTOR CABLES STRANDED MULTI-CONDUCTOR CABLES SPEAKER/ZIP WIRE THERMOSTAT CABLE FIRE ALARM CABLE
Stephen G. Whitley, Senior Vice President & Chief Operating Officer
Peter T. Brandien Vice President, System Operations To: Stephen G. Whitley, Senior Vice President & Chief Operating Officer From: Peter T. Brandien Re: Discussion of Cable Technologies Under Evaluation
01. HARTING RJ INDUSTRIAL RJ45 ETHERNET CONNECTORS
. HARTING RJ INDUSTRIAL ETHERNET CONNECTORS Ethernet is is coming up to standard industrial interface. Therefore, automation devices such as controllers, sensors and actuators feature possess on one or
Gulf Cable & Electrical Ind. Co.
CONTENTS INTRODUCTION PRODUCT RANGE I PRODUCT DATA TABLES XLPE INSULATED 600/1000V CABLES Two Core Cables CU/XLPE/PVC/LC/PVC/SWA/PVC 1 Three Core Cables CU/XLPE/PVC/LC/PVC/SWA/PVC 2 Four Core Cables CU/XLPE/PVC/LC/PVC/SWA/PVC
ENERGY. TECSUN DUO (PV) Twin Cables for Photovoltaics
ENERGY TECSUN DUO (PV) Twin Cables for Photovoltaics Auswahlkriterien Manufacturer Trademark Approvals Application Prysmian Kabel und Systeme GmbH Kabel- und Leitungswerk Neustadt bei Coburg / Germany
APPLICATION ORIENTED DESIGN OF CABLES
APPLICATION ORIENTED DESIGN OF CABLES Mrs. Rohini Bhattacharyya, Dubai cables Ltd.P. O. Box 11529,Dubai. [email protected] Mr. Nawaf Ahmad Al Mohaideb Dubai Cables Ltd. P. O. Box 11529, Dubai. [email protected]
Commercial Coaxial Cable
Commercial Coaxial Cable For the Best in COMMERCIAL TV Reception Solutions! Do you require a Digital TV reception system for your next project? Matchmaster can supply For The Best Design and supply of
BRÖCKSKES D-VIERSEN PV1-F 4,0 mm BRÖCKSKES D-VIERSEN PV1-F 4,0 mm d d 2 2 C VDE-REG.-Nr. 8292 10/2009
d BRÖCKSKES BRÖCKSKES D-VIERSEN D-VIERSEN PV1-F PV1-F 4,0 mm 4,0 2 mm VDE-REG.-Nr. 2 C 8292 10/2009 s - THE COMPANY DIN EN ISO 9001 More than 60 years of experience in temperature measurement and control
ELEVATOR TRAVELING CABLE - DESIGN EVOLUTION
ELEVATOR TRAVELING CABLE - DESIGN EVOLUTION by Richard Laney Introduction Elevator traveling cable is a vital link between the elevator car and controller. In conventional elevators, all power and signal
D A T A C O M M U N I C A T I O N S C O M P E T E N C E C E N T E R
F l a m e T e s t S t a n d a r d s f o r D a t a C o m m u n i c a t i o n s C a b l e M a r c h 2 0 0 7 D A T A C O M M U N I C A T I O N S C O M P E T E N C E C E N T E R Table of Contents Executive
Design Techniques for High Power RF Coaxial Cable Assemblies
Design Techniques for High Power RF Coaxial Cable Assemblies Tony Martiniello Chief Technology Officer Primary Considerations Performance Electrical-Mechanical-Environmental Application Prioritizing-Trade-offs
INTERNATIONAL TELECOMMUNICATION UNION SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT
INTERNATIONAL TELECOMMUNICATION UNION )454, TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU (10/96) SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT /PTICAL
RF & Microwave cable assemblies C291
ERTIFIED C AS 9100 RF & Microwave cable assemblies C291 B CONTENTS Pages Introduction... B-4 Specify the right cable for your application... B-5 Finder guide cables vs insertion loss... B-6 to B-7 Flexible
Unified requirements for systems with voltages above 1 kv up to 15 kv
(1991) (Rev.1 May 2001) (Rev.2 July 2003) (Rev.3 Feb 2015) Unified requirements for systems with voltages above 1 kv up to 15 kv 1. General 1.1 Field of application The following requirements apply to
Cables, Cable Laying & Accessories Manual
Distribution Business Cables, Cable Laying & Accessories Manual Database ref: File Ref: Title Page & Revision Log For Cables & Access v4 - Nov 2003.doc Manual Name: Cables & Accessories Manual Version
PVC Insulating Tape. Electrical Tapes
Electrical Tapes 7 3M offer a range of over 30 electrical tapes and mastics for insulation, jointing, corrosion protection, all weather protection and environmental sealing. From Scotch 33+ Vinyl tape
XLPE Land Cable Systems User s Guide. Rev 5
XLPE Land Cable Systems User s Guide Rev 5 CONTENT XLPE Land Cable Systems Introduction... 3 Design, installation and testing... 4 XLPE cables... 4 Cable accessories... 4 Installation of XLPE cable systems...
6 ELECTRICAL PARAMETERS
6 ELECTRICAL PARAMETERS For power, low voltage and medium voltage cables, cross section nominal areas are calculated in taking into account several parameters as: permissible current carrying capacities
OPTICAL FIBER CABLES
OPTICAL FIBER CABLES CONTENTS INTRODUCTION QUALITY ASSURANCE RECOMMENDED ORDERING PARAMETERS GENERALITIES :. Advantage. General Description.. Construction.. Principle TYPICAL SPECIFICATIONS OF OPTICAL
ENERGY. TECWATER S1BN8-F 0,6/1 kv. Cable for Water Application
ENERGY TECWATER S1BN8-F 0,6/1 kv Cable for Water Application Technical Data Electrical parameters Thermal parameters Trademark Type designation Specification Approval Application Rated voltage Maximum
C A B L E P R O T E C T I O N
Safe cable protection! Elematic Cabling Systems produces in own plants a wide range of products for the cable protection, such as wiring spirals, insulated tubing, heat shrinkable tubing, etc. These products
Fiber Optic Specifications
Fiber Optic Specifications All Fiber Optic shall be Corning Altos Single Mode OS1 Outdoor Loose Tube Gel Free Cable Corning Fiber Products only will be accepted and no substitutions or alternates will
Accelerating Light. Copper Cabling Solutions. Category 6A
Accelerating Light Copper Cabling Solutions Category 6A Category 6A Copper Cabling Solutions Fibernet designs and manufactures premium, high performance copper communication infrastructure and connectivity
Network Standard Advice No. 1420C 9/6/2011
Network Standard Advice No. 1420C 9/6/2011 TO: Customers, Service Providers and Ausgrid Staff. Advisory Note on Changes to the Use of 11kV Cable Types. Introduction This Network Standard Advice (NSA) provides
Building Cables and Wires
Building Cables and Wires 4 Introduction alfanar is equipped with state-of-the-art manufacturing facilities such as latest machineries, instrumentation, quality control and testing laboratory, etc., for
White paper. SACE Tmax XT Circuit-Breaker Terminals and Connection
White paper SACE Tmax XT Circuit-Breaker Terminals and Connection Circuit-Breaker Terminals and Connections Index Introduction... 2 1. Components used for wiring... 3 1.1. Electrical...3 1.2. Flexibility
e-mobility Special cables for electric vehicles Coroplast Fritz Müller GmbH & Co. KG Tapes Cables Cable Assemblies
www.echtzeit.com e-mobility Coroplast Fritz Müller GmbH & Co. KG Tapes Cables Cable Assemblies Special cables for electric vehicles Wittener Straße 271 D-42279 Wuppertal Phone +49(0)202.2681.228 Fax +49(0)202.2681.360
The color scheme for the fibers in the cable complies with the Telcordia (formerly Bellcore) specification.
10 Cables The cables referred to below are provided with standard single- and multimode fibers. Other commercially available fibers can be provided on request. The bare fibers are colored in all cases
CABLE SPECIFICATION CAN CAB RJ45-SUBD9
CABLE SPECIFICATION All technical information contained in this document is the exclusive property of STI and may neither be used nor disclosed without its prior written consent. AAV 33801 1/8 Connector
HIGH- AND EXTRA-HIGH-VOLTAGE GLOBAL CABLE SYSTEM SOLUTIONS Rely On Our Experience... Experience Our Capabilities
HIGH- AND EXTRA-HIGH-VOLTAGE GLOBAL CABLE SYSTEM SOLUTIONS Rely On Our Experience... Experience Our Capabilities RELY ON OUR EXPERIENCE... EXPERIENCE OUR CAPABILITIES For close to half a century, Silec
Specification SFTP CAT6 Network Cable 23AWG CU
Specification SFTP CAT6 Network Cable 23AWG CU S/FTP CAT6 Shielded S/FTP PVC Cable 23AWG 4pair Solid, Wooden drum 1000 Grey CAT6 600MHZ CM Shielded (S/FTP) Solid Cable: Our CAT6 600MHZ Shielded (S/FTP)
Standard Buccaneer - Ethernet
IP6 rated compliant PUR jacket on cable Shielded system shielded coupler Shroud on RJ45 Screw coupling Rewireable flex connector PCB mounted panel connector IDC termination panel connector Earth lead version
Caledonian Submersible Pump Cables for Oil Industry >> IEEE 1018 >> IEEE 1019 >> API RP 11S5
Caledonian Submersible Pump Cables for Oil Industry >> IEEE 1018 >> IEEE 1019 >> API RP 11S5 Caledonian Windmill Cables COMPANY PROFILE Table of Content Caledonian, established in 1978, offers one of the
Fire retardant IEC 60332-1
300 / 500 V Description Approval Certificates VDE Reg N 7691 Application In dry and moist rooms for light mechanical stresses. Outdoors only when protected. Not in water. As supply and interconnecting
Temperature Permissible ambient temperature. Weather Resistance to severe weather conditions. Impacts Cable mechanical resistance to impacts
Airfield Cables Issue 10/2003 Piktogramme Temperature Permissible ambient temperature Weather Resistance to severe weather conditions Impacts Cable mechanical resistance to impacts Chemical attacks Resistance
Trial Exams C. Standards and Regulations. Examination No: GH-08-C- 1 hour and 5 minutes plus 10 minutes reading time
Trial Exams C Standards and Regulations Examination No: GH-08-C- This test is intended to gauge your knowledge of essential information contained within AS/CA S009:2013. To qualify for an allpication to
Session 14 Cable Support Systems
Session 14 Cable Support Systems Cable Support Systems in the IEC World A new IEC Standard, IEC61537 2001 has been developed If full details of the cabling layout are available then the likely cable load
HIGH VOLTAGE XLPE CABLE SYSTEMS. Technical User Guide
HIGH VOLTAGE XLPE CABLE SYSTEMS Technical User Guide Content 1. General information on High Voltage XLPE Cable Systems 1.1. Introduction 1.2. Cable selection process 1.3. Service life 3 3 3 4 2. Cable
(PREVIEW) Indian Standard COMMON SPECIFICATION FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR STANDARDS
(PREVIEW) Indian Standard COMMON SPECIFICATION FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR STANDARDS IS 12729:2004 IEC 60694(2002) 1.1 Scope This International Standard applies to a.c. switchgear and controlgear,
Trunk Cables. www.teletronik.com
Trunk Cables www.teletronik.com Brief Introduction Teletronik TC series coaxial cable was developed to meet the increasing demand of tomorrow's broadband networks. TC series cable has the highest reliability
100% EMI Emission Containment
100% EMI Emission Containment Designed for Longer Service Life Highly Flexible for Easier Handling and Faster Installation Authorized Distributor Industrial VFD Cables Index n Variable Frequency Drive
SCHEDULE ' A' TECHNICAL SPECIFICATION FOR 11/22/33KV H.T.XLPE POWER CABLE FOR DISTRIBUTION NETWORK IN MAHARASHTRA (SPECIFICATION NO.
SCHEDULE ' A' TECHNICAL SPECIFICATION FOR 11/22/33KV H.T.XLPE POWER CABLE FOR DISTRIBUTION NETWORK IN MAHARASHTRA (SPECIFICATION NO.MM/I/HTXLPE/2006) MAHARASHTRA STATE ELECTRICITY DISTRIBUTION CO.LTD.
