Exane 125 Drilling Rig and Commercial Marine Cable
|
|
- Dortha Abigayle Lawrence
- 8 years ago
- Views:
Transcription
1 Exane 125 Drilling Rig and Commercial Marine Cable Over 20 Years of Superior Perfomance On Oil Rigs Around The World Engineered Wire & Cable for Demanding Applications Certified as Type P per IEEE-45 STD 1998 Listed by UL for Marine Applications to STD UL 1309 Meets IEC Category A Flame Test Approved by ABS, DNV, Lloyds, USCG and Canadian Coast Guard CSA listed to C22.2 No. 245 ITS listed to the performance requirements of IEC 92-3 ITS listed to the performance requirements of IEC
2 The Ideal Solution for Harsh Oil Rig Environments Found Anywhere in the World Wide Size Range (#18 AWG-1111 MCM) (1.0 mm mm 2 ) Single and Multiconductor Up to 91 Conductors Flexible Stranding Tinned Copper Conductors ASTM B33, B8 and B172 Irradiation Crosslinked Polyolefin (Exane ) Free Stripping without Separator over Strand High Energy Irradiation Process. Produces Thermoset Able to Withstand Thermal Overloads Heavy Duty Arctic Grade Neoprene Jacket per ICEA S Wide Temperature Range -55 C to 125 C Passes Cold Bend at -55 C, and Cold Impact at -40 C Excellent Electrical Properties Highly Flame Retardant (VW-1, IEEE-383, IEEE1202, FT-4, IEC Cat. A) Excellent Moisture Resistance Superior Oil and Chemical Resistance Superior Abrasion, Crush & High Temperature Cut Thru Resistance Easy to Handle During Installation Resistant to Oilfield Drilling Muds Note: Special wire and cable constructions available check with factory. Product available with blue jackets to indicate intrinsically safe circuit. 1
3 EXANE Product Line A Unique Combination of Features. Wire and Cable with Wide Range of World Wide Approvals. ITS Listed to IEEE & IEEE , Type P Listed UL 1309 Marine Shipboard Cable Listed CSA C22.2 No. 245 Marine Shipboard Cable ITS Type Approved in accordance with IEC 92-3 and IEC Accepted by U.S. Coast Guard Meets requirements of 46 CFR Parts 110 & 111 Accepted by Canadian Coast Guard Approved by ABS Approved by DNV Approved by Lloyd s U.K., Register of Shipping Approved by NVE Approved by Korean Register of Shipping Meets IEC Cat. A Flame Test Meets IEEE 1202 Vertical Cable Tray Flame Test Listed by UL as Type CWCMC for cables with continuously welded and corrugated aluminum armor in accordance with UL Engineering Information Ampacity Ratings Based on the Following* 95 C IEC C Ambient in Free Air 100 C IEEE-45 STD 45 C Ambient in Free Air 125 C ICEA Pub. 45 C Ambient in Free Air *Contact factory for specific installation conditions Recommended Minimum Dynamic Bend Radius Unarmored 6X Finished Cable Diameter Sheathed Cable 8X Finished Cable Diameter *Contact factory for specific installation conditions Standard O.D. Tolerances ± 10% Soft Metric Diameter Conversion Factor Inches to Millimeters: Multiply by 25.4 Electrical Values #18 AWG Pairs and Triads Capacitance pf/ft = 36 Inductance milli-henries/1000 ft =.126 Resistance Ohms/ C = 6.22 #16 AWG Pairs and Triads Capacitance pf/ft = 39 Inductance milli-henries/1000 ft =.117 Resistance Ohms/ C = 4.82 #14 AWG Pairs Capacitance pf/ft = 28 Inductance milli-henries/1000 ft =.104 Resistance Ohms/ C = 3.05 * Contact factory for special electrical requirements. 2
4 Oil Rig/Commercial Marine Cable Single Conductor Power RSCC DAA 1048B Multi-Conductor Power RSCC DAC 1048C Conductor Flexible stranded, tin-coated copper (various strandings) Conductor Flexible stranded, tin-coated copper (various strandings) Armor Crosslinked Polyolefin Crosslinked Polyolefin Armor Inner Jacket Neoprene Sheath Neoprene Outer Sheath Neoprene 600 & 2000 Volt Single Conductor Power, Unarmored or Sheathed. Conductor: Flexible, Annealed, Tinned Copper per ASTM B33, B8 and B172 : Exane -125 Crosslinked Polyolefin 125 C (Colors as Required) Armor: Bronze, Tinned Copper or Aluminum Braid Sheath: Heavy Duty Arctic Neoprene 600 Volt Multi-Conductor Power Cable, Unarmored or Armored and Sheathed. Conductors: Flexible, Annealed, Tinned Copper per ASTM B33, B8 and B172 : Exane -125 Crosslinked Polyolefin 125 C Color Code: IEEE-45, UL1309 or as Specified by Customer Fillers: When Required, Flame Retardant and Non-Hygroscopic Binder Tape: Non-Hygroscopic and Non-Wicking Inner Jacket: Heavy Duty Arctic Neoprene Armor: Bronze, Tinned Copper or Aluminum Braid Outer Sheath: Heavy Duty Arctic Neoprene 3
5 Oil Rig/Commercial Marine Cable Multi-Conductor Control RSCC DAC 1048C Multi-Conductor Instrumentation RSCC DAC 1048C Crosslinked Polyolefin Conductor Flexible stranded, tin-coated copper (various strandings) Binder Tape Conductor Flexible stranded, tin-coated copper (various strandings) Crosslinked Polyolefin Inner Jacket Neoprene Drain Wires Tin-coated copper Armor Shield Tapes Inner Jacket Neoprene Outer Sheath Neoprene Armor Outer Sheath Neoprene 600 Volt Multi-Conductor Control Cable, Unarmored or Sheathed Conductors: Annealed, Tinned Copper per ASTM B33, B8 and B172 : Exane -125 Crosslinked Polyolefin 125 C Color Code: IEEE-45, UL1309 or as Specified by Customer Fillers: When Required, Flame Retardant and Non-Hygroscopic Binder Tape: Non-Hygroscopic and Non-Wicking Inner Jacket: Heavy Duty Arctic Neoprene Armor: Bronze, Tinned Copper or Aluminum Braid Outer Sheath: Heavy Duty Arctic Neoprene 600 Volt Multi-Shielded Pairs or Triples with Overall Shield, Unarmored or Sheathed Conductors: Annealed, Tinned Copper per ASTM B33, B8 and B172 : Exane -125 Crosslinked Polyolefin 125 C Pair or Triple Assembly: Two or Three Conductors Twisted with a Tin-Coated Copper Drain Wire, a Helically Applied Aluminum/ Ployester Laminated Tape Shield Cabling: Required Number of Pairs or Triples Cabled Together Color Code: IEEE-45, UL1309 or as Specified by Customer Fillers: When Required, Flame Retardant and Non-Hygroscopic Overall Shield System: Helically Applied Aluminum/Polyester Laminated Tape Shield in Continuous Contact with Tin-Coated Copper Drain Wire Inner Jacket: Heavy Duty Arctic Neoprene Armor: Bronze, Tinned Copper or Aluminum Braid Outer Sheath: Heavy Duty Arctic Neoprene 4
6 One Conductor Wire: 600 Volt Nominal Nominal Conductor Overall Weight Nominal Weight Nominal Weight Product Diameter Diameter Lbs per Diameter Lbs per Diameter Lbs per Size Number* Inches Inches M FT Inches M FT Inches M FT 22 01C22-600V C20-600V C18-600V C16-600V C14-600V C12-600V C10-600V C8-600V C6-600V C5-600V C4-600V C3-600V C2-600V C1-600V /0 01C1/0-600V /0 01C2/0-600V /0 01C3/0-600V Ampacity** ICEA IEEE-45 IEC 125 C 100 C 95 C 14 N/A Note: #18 AWG through #3/0 AWG also available in 2000V rated thicknesses when required. *Exane-125 Ordering Part Number Unarmored use product number. Example: 01C V. Armored only add the letter B. Example: 01C VB. Sheathed add the letters BN. Example: 01C V BN. **Ampacity Ratings Based on the Following 95 C IEC 92-3 Ampacity in Free 45 C Ambient 100 C IEEE-45 STD 1998 in Free 45 C Ambient 125 C ICEA Pub. P in Free 45 C Ambient **Contact Factory for sizes 4/0 AWG to 1111KCMIL. One Conductor Power Cable: 2000 Volts (Heavy Duty) Nominal Nominal Conductor Overall Weight Nominal Weight Nominal Weight Product Diameter Diameter Lbs per Diameter Lbs per Diameter Lbs per Size Number* Inches Inches M FT Inches M FT Inches M FT 4/0 01C4/0-HD C262-HD C313-HD C373-HD C444-HD C535-HD C646-HD C777-HD C1111-HD Ampacity** ICEA IEEE-45 IEC 125 C 100 C 95 C *Exane-125 Ordering Part Number Unarmored use product number. Example: 01C262-HD. Armored only add the letter B. Example: 01C262-HDB. Sheathed add the letters BN. Example: 01C262-HD BN. **Ampacity Ratings Based on the Following 95 C IEC 92-3 Ampacity in Free 45 C Ambient 100 C IEEE-45 STD 1998 in Free 45 C Ambient 125 C ICEA Pub. P in Free 45 C Ambient Contact factory for specific environmental conditions. 5
7 One Conductor Wire: 2000 Volt (Standard) Nominal Nominal Conductor Overall Weight Nominal Weight Nominal Weight Product Diameter Diameter Lbs per Diameter Lbs per Diameter Lbs per Size Number* Inches Inches M FT Inches M FT Inches M FT 18 01C18-2KV C16-2KV C14-2KV C12-2KV C10-2KV C8-2KV C6-2KV C5-2KV C4-2KV C3-2KV C2-2KV C1-2KV /0 01C1/0-2KV /0 01C2/0-2KV /0 01C3/0-2KV /0 01C4/0-2KV C262-2KV C313-2KV C373-2KV C444-2KV C535-2KV C646-2KV C777-2KV C1111-2KV Ampacity** ICEA IEEE-45 IEC 125 C 100 C 95 C *Exane-125 Ordering Part Number Unarmored use product number. Example: 01C262-2KV. Armored only add the letter B. Example: 01C262-2KVB. Sheathed add the letters BN. Example: 01C262-2KV BN. **Ampacity Ratings Based on the Following 95 C IEC 92-3 Ampacity in Free 45 C Ambient 100 C IEEE-45 STD 1998 in Free 45 C Ambient 125 C ICEA Pub. P in Free 45 C Ambient Contact factory for specific environmental conditions. *** 4/0 AWG and larger are per UL1309/CSA C22.2 No AWG to 3/0 AWG are in accordance with IEEE 45 and UL 1309/CSA C22.2 No
8 Two Conductor Power Cable: 600 Volt Nominal Weight Nominal Weight Nominal Weight Product Diameter Lbs per Diameter Lbs per Diameter Lbs per Size Number* Inches M FT Inches M FT Inches M FT 16 02C C C C C C C C C C C /0 02C1/ /0 02C2/ /0 02C3/ /0 02C4/ C C C C C C C Ampacity** ICEA IEEE-45 IEC 125 C 100 C 95 C Three Conductor Power Cable: 600 Volt Nominal Weight Nominal Weight Nominal Weight Product Diameter Lbs per Diameter Lbs per Diameter Lbs per Size Number* Inches M FT Inches M FT Inches M FT 16 03C C C C C C C C C C C /0 03C1/ /0 03C2/ /0 03C3/ /0 03C4/ C C C C C C C Ampacity** ICEA IEEE-45 IEC 125 C 100 C 95 C *Exane-125 Ordering Part Number Unarmored use product number. Example: 03C4. Armored only add the letter B. Example: 03C4B. Sheathed add the letters BN. Example: 03C4BN. **Ampacity Ratings Based on the Following 95 C IEC Ampacity Regulations in Free 45 C Ambient 100 C IEEE-45 STD 1998 in Free 45 C Ambient 125 C ICEA Pub. P in Free 45 C Ambient Contact factory for specific environmental conditions. 7
9 Four Conductor Power Cable: 600 Volt Nominal Weight Nominal Weight Nominal Weight Product Diameter Lbs per Diameter Lbs per Diameter Lbs per Size Number* Inches M FT Inches M FT Inches M FT 16 04C C C C C C C C C C C /0 04C1/ /0 04C2/ /0 04C3/ /0 04C4/ C C C C C C C Ampacity** ICEA IEEE-45 IEC 125 C 100 C 95 C Five Conductor Power Cable: 600 Volt Nominal Weight Nominal Weight Nominal Weight Product Diameter Lbs per Diameter Lbs per Diameter Lbs per Size Number* Inches M FT Inches M FT Inches M FT 16 05C C C C C C C C C C C /0 05C1/ /0 05C2/ /0 05C3/ /0 05C4/ Ampacity** ICEA IEEE-45 IEC 125 C 100 C 95 C *Exane-125 Ordering Part Number Unarmored use product number. Example: 05C2. Armored only add the letter B. Example: 05C2B. Sheathed add the letters BN. Example: 05C2BN. **Ampacity Ratings Based on the Following 95 C IEC Ampacity Regulations in Free 45 C Ambient 100 C IEEE-45 STD 1998 in Free 45 C Ambient 125 C ICEA Pub. P in Free 45 C Ambient Contact factory for specific environmental conditions. 8
10 #16 AWG Multi-Conductor Control Cable: 600 Volt Number Nominal Weight Nominal Weight Nominal Weight of Product Diameter Lbs per Diameter Lbs per Diameter Lbs per Cond. Number* Inches M FT Inches M FT Inches M FT 4 04C C C C C C C C C C C C Ampacity** ICEA IEEE-45 IEC 125 C 100 C 95 C #14 AWG Multi-Conductor Control Cable: 600 Volt Number Nominal Weight Nominal Weight Nominal Weight of Product Diameter Lbs per Diameter Lbs per Diameter Lbs per Cond. Number* Inches M FT Inches M FT Inches M FT 4 04C C C C C C C C C C C C C Ampacity** ICEA IEEE-45 IEC 125 C 100 C 95 C #12 AWG Multi-Conductor Control Cable: 600 Volt Unarmored Armored B Sheathed BN Number Nominal Weight Nominal Weight Nominal Weight of Product Diameter Lbs per Diameter Lbs per Diameter Lbs per Cond. Number* Inches M FT Inches M FT Inches M FT 4 04C C C C C C C Ampacity** ICEA IEEE-45 IEC 125 C 100 C 95 C *Exane-125 Ordering Part Number Unarmored use product number. Example: 04C16. Armored only add the letter B. Example: 04C16B. Sheathed add the letters BN. Example: 04C16BN. **Ampacity Ratings Based on the Following 95 C IEC Ampacity Regulations in Free 45 C Ambient 100 C IEEE-45 STD 1998 in Free 45 C Ambient 125 C ICEA Pub. P in Free 45 C Ambient Contact factory for specific environmental conditions. 9
11 #18 AWG Instrumentation Cable Shielded Pairs, Overall Shield: 600 Volts Number Nominal Weight Nominal Weight Nominal Weight of Product Diameter Lbs per Diameter Lbs per Diameter Lbs per Pairs Number* Inches M FT Inches M FT Inches M FT 1 01P18I/S-OS P18I/S-OS P18I/S-OS P18I/S-OS P18I/S-OS P18I/S-OS P18I/S-OS P18I/S-OS P18I/S-OS P18I/S-OS P18I/S-OS P18I/S-OS #16 AWG Instrumentation Cable Shielded Pairs, Overall Shield: 600 Volts Number Nominal Weight Nominal Weight Nominal Weight of Product Diameter Lbs per Diameter Lbs per Diameter Lbs per Pairs Number* Inches M FT Inches M FT Inches M FT 1 01P16I/S-OS P16I/S-OS P16I/S-OS P16I/S-OS P16I/S-OS P16I/S-OS P16I/S-OS P16I/S-OS P16I/S-OS P16I/S-OS P16I/S-OS P16I/S-OS #14 AWG Instrumentation Cable Shielded Pairs, Overall Shield: 600 Volts Number Nominal Weight Nominal Weight Nominal Weight of Product Diameter Lbs per Diameter Lbs per Diameter Lbs per Pairs Number* Inches M FT Inches M FT Inches M FT 1 01P14I/S-OS P14I/S-OS P14I/S-OS P14I/S-OS P14I/S-OS P14I/S-OS P14I/S-OS P14I/S-OS P14I/S-OS *Exane-125 Ordering Part Number Unarmored use product number. Example: 04P14I/S-OS. Armored only add the letter B. Example: 04P14I/S-OS-B. Sheathed add the letters BN. Example: 04P14I/S-OS-BN. 10
12 #18 AWG Instrumentation Cable Shielded Triads, Overall Shield: 600 Volts Number Nominal Weight Nominal Weight Nominal Weight of Product Diameter Lbs per Diameter Lbs per Diameter Lbs per Triads Number* Inches M FT Inches M FT Inches M FT 1 01T18I/S-OS T18I/S-OS T18I/S-OS T18I/S-OS T18I/S-OS T18I/S-OS T18I/S-OS T18I/S-OS *Exane-125 Ordering Part Number Unarmored use product number. Example: 04T18I/S-OS. Armored only add the letter B. Example: 04T18I/S-OS-B. Sheathed add the letters BN. Example: 04T18I/S-OS-BN. #16 AWG Instrumentation Cable Shielded Triads, Overall Shield: 600 Volts Number Nominal Weight Nominal Weight Nominal Weight of Product Diameter Lbs per Diameter Lbs per Diameter Lbs per Triads Number* Inches M FT Inches M FT Inches M FT 1 01T16I/S-OS T16I/S-OS T16I/S-OS T16I/S-OS T16I/S-OS T16I/S-OS T16I/S-OS *Exane-125 Ordering Part Number Unarmored use product number. Example: 06T16I/S-OS. Armored only add the letter B. Example: 06T16I/S-OS-B. Sheathed add the letters BN. Example: 06T16I/S-OS-BN. 11
13 12
14 A Division of RSCC Cable Group Exane VFD Power Cable 600V 2KV 2KV (HD) Armor (Optional) Jacket Power Conductor (X3) Exane VFD Power Cable Three Conductor Rated 110 C Sheath (Optional) Shield Ground Conductors (X3) ABS, UL, CSA, Lloyds RSCC Type VFD Power Cables are high performance cables, designed for use in applications where high speed (IGBT Type) AC drives will be utilized. Type VFD cables are flexible, and employ an optimized Tinned Copper braid shield with an Aluminum/Polyester laminated tape to provide exceptional shielding characteristics. The unarmored cables are dual listed as UL Type TC, and Marine Shipboard Cables. Features Optimized tinned copper braid with Aluminum/Polyester laminated tape shielding system provides 100% coverage and an effective electrostatic shield for isolation of the high frequency currents and potentials, and an effective low impedance path to ground for A.C. drive applications. High Dielectric Strength Withstands Voltage Spikes (2-3X) Symmetrical Cable Construction 3 Phase & 3 Ground Conductors Cancellation of Magnetic Fields Lower Ground Conductor Current Flow Reduction in Common Mode Noise Flexible Cable Class I Conductor and Braid Shield High Crush and Impact Resistance Non-Armored Meets UL 2225 (Type MC) with no Armor Proven 30 Year Exane Reliability Irradiation Cross-Linked Polyolefin Performance Standards ITS and UL Listed as Marine Shipboard UL 1309 Type X110 IEEE 45 & IEEE 1580 Shipboard Un-Armored Also UL Type TC CSA Listed as Marine Ship Board CSA C22.2 No 245 Type X110 ITS Listed as Marine Shipboard IEC Meets Vertical Tray Flame Tests IEEE 1202 IEC Category A Meets Cold Temperature Requirements UL and CSA -40 C Cold Impact Rated -55 C Cold Bend Sheathed Cables Suitable for Class I, Div. 1 & Zone 1 Unarmored Cable Suitable for Class I, Div. 2 & Zone 2 Construction Conductors: Annealed, Flexible Tinned Copper, Class I per ASTM B33, B172, UL 1309 & CSA C22.2 No. 245 : Proprietary, irradiation cross-linked Polyolefin (Exane ). Circuit Identification: Power Conductors: Dark Gray, Red, Blue Ground Conductors: Green Ground Conductors: Three segmented, Green Insulated grounding conductors with the same voltage rating as the circuit conductors. Fillers: Flame retardant, fibrillated Polypropylene as required. Shield: Overall, optimized Tinned Copper braid with Aluminum/Polyester laminated tape providing 100% coverage. Jacket: Black, heavy duty, arctic grade Neoprene. Colored Neoprene available on request Armor (optional): Braided Bronze armor. Aluminum or Tinned Copper braided armor available on request. Sheath (optional): Black, heavy duty, arctic grade Neoprene. Colored Neoprene available on request 13
15 600V EXANE VFD 600V 3/C Type VFD Flexible Marine Variable Frequency Drive Cables 3/C Cables with AL/Polyester Tape Shield + T.C. Braid and 3 Insulated Tinned Copper Grounds Conductor Diameter Over T.C. Insulated Grounds Part No. VFD-3C- Unarmored Cables Armored & Sheathed Cables Nominal Diameter Weight Part No. VFD-3C- Nominal Diameter AWG Sq. mm Inches mm No.X AWG Inch mm lb/1,000ft Kg/Km Inch mm lb/1,000ft Kg/Km Weight X V V-BN X V V-BN X V V-BN X V V-BN X V V-BN X V V-BN X V V-BN X V V-BN X V V-BN X V V-BN / X 10 1/0-600V /0-600V-BN / X 10 2/0-600V /0-600V-BN / X 8 3/0-600V /0-600V-BN / X 8 4/0-600V /0-600V-BN X V V-BN X V V-BN X V V-BN X V V-BN X V V-BN X V V-BN Notes: (1) Tolerance on insulated conductor diameter = +/- 10% (= < 6 AWG) (2) Tolerance on overall cable diameters = +/- 5% Notes: (1) Tolerance on Insulated conductor diameter = +/- 5% (= > 5 AWG) 14
16 2KV Heavy Duty EXANE VFD 2 KV Heavy Duty Type VFD Flexible Marine Variable Frequency Drive Cables 3/C Cables with AL/Polyester Tape Shield + T.C. Braid and 3 Insulated Tinned Copper Grounds Conductor Diameter Over T.C. Insulated Grounds Part No. VFD-3C-HD Unarmored Cables Armored & Sheathed Cables Nominal Diameter Weight Part No. VFD-3C-HD Nominal Diameter AWG Sq. mm Inches mm No.X AWG Inch mm lb/1,000ft Kg/Km Inch mm lb/1,000ft Kg/Km Weight 4/ X 8 4/0-2KV /0-2KV-BN X KV KV-BN X KV KV-BN X KV KV-BN X KV KV-BN X KV KV-BN X KV KV-BN Notes: (1) Tolerance on insulated conductor diameter = +/- 5% (2) Tolerance on overall cable diameters = +/- 5% 15
17 2KV EXANE VFD 2KV 3/C Type VFD Flexible Marine Variable Frequency Drive Cables 3/C Cables with AL/Polyester Tape Shield + T.C. Braid and 3 Insulated Tinned Copper Grounds Conductor Diameter Over T.C. Insulated Grounds Part No. VFD-3C- Unarmored Cables Armored & Sheathed Cables Nominal Diameter Weight Part No. VFD-3C- Nominal Diameter AWG Sq. mm Inches mm No.X AWG Inch mm lb/1,000ft Kg/Km Inch mm lb/1,000ft Kg/Km Weight X KV KV-BN X KV KV-BN X KV KV-BN X KV KV-BN X KV KV-BN X KV KV-BN X KV KV-BN X KV KV-BN X KV KV-BN X KV KV-BN / X10 1/0-2KV /0-2KV-BN / X 10 2/0-2KV /-2KV-BN / X 8 3/0-2KV /0-2KV-BN / X 8 4/0-2KV /0-2KV-BN X KV KV-BN X KV KV-BN X KV KV-BN X KV KV-BN X KV KV-BN X KV KV-BN Notes: (1) Tolerance on insulated conductor diameter = +/- 10% (= < 6 AWG) (2) Tolerance on overall cable diameters = +/- 5% Notes: (1) Tolerance on Insulated conductor diameter = +/- 5% (= > 5 AWG) 16
18 17
19 World Class Engineered Cable Exane MR Power, Control & Instrumentation Cables Armored & Unarmored (Offshore & Land Rigs) Outer Sheath Mud & Oil Resistant Inner Jacket Mud & Oil Resistant Conductor Tin-Coated Copper IEEE 1580 Drilling Fluid Resistant 1KV; 2KV; 2KV(HD); 125 C UL/CSA Marine Shipboard Rated at 110 C Armor Crosslinked Polyolefin Features Thermoset insulation Heat, sunlight, & moisture resistant Extremely flame retardant Easy to install Easy to strip has no separator tape Extremely flexible Flexible Tin-coated conductors for improved terminations and corrosion resistance Pigmented insulation with vivid colors Passes the UL 2225 Crush & Impact Test requirements for Type MC-HL Passes minus 55 C cold bend Passes minus 40 C cold impact Performance Standards IEEE 45/1580 Type P UL 1309 X110 Marine Shipboard Cable CSA C22.2 No. 245 X110 Marine Shipboard Intertek Testing Service (ETL) certified as Type P Passes IEEE 1202 & FT-4, 70,000 Btu/hr Vertical Tray Flame Tests Passes the IEC Category A/F Flame Test Type Approved by ABS, DNV and Lloyd s Register NA Armored & Sheathed cables are suitable for use in Class 1, Division 1 and Zone 1 hazardous locations Unarmored cables are suitable for use in Class 1, Div 2 & Zone 2 Passes mud & oil resistance per IEC Annex D Scope Exane MR multi-conductor power cables, armored & unarmored, rated 1KV, 2KV and 2KVHD are an extremely tough construction ideally suited for use in rugged marine/oil rig applications exposed to drilling fluids and muds. The Exane insulation is radiation crosslinked and provides outstanding physical properties, resistance to abrasion, cut-through, low and high temperatures, drilling fluids and muds, sunlight, flame, and moisture. Exane MR is extremely tough and durable and withstands the arduous environmental conditions experienced in offshore mobile drilling units (MODU), FPSO s, TLP s and land rigs for oil and gas drilling rigs. Exane MR s 125 C temperature rating for short durations lends itself to handle higher ampacity levels and higher safety margins in the field. It s extremely flexible design and tightly controlled dimensions lead to benefits regarding lower weight, tray fill, ease of installation and long service life in drag chains. Construction Conductor: Flexible, soft annealed tinned copper per ASTM B33 & IEEE 1580 : Irradiation cross-linked Polyolefin, Exane 125 C Circuit Identification: Standard Vivid pigmented insulation colors per IEEE Optional Dk. Gray + No s Fillers: When required, flame retardant and non-hygroscopic Inner Jacket: Black, cross-linked chlorosulfonated Polyethylene (CSPE). Sunlight resistant Armor (optional): Bronze Braid Standard. Tinned Copper Braid Optional Outer Jacket (optional): Black, cross-linked chlorosulfonated Polyethylene (CSPE). Sunlight resistant Temperature Rating: RSCC Wire & Cable rated 125 C, UL/CSA 110 C, IEEE 100 C A Marmon Wire & Cable / Berkshire Hathaway Company RSCC Wire & Cable LLC Bradley Park Road East Granby, CT USA Tel: Fax: For more information contact the RSCC factory at
20 YES How To Handle Cable Reels NO Always load and store reels upright on their flanges and block securely. Upended heavy reels will often be damaged. Reels can be hoisted with a properly secured shaft extending through both flanges. Do not lift by a single reel flange. Cable or reel may be damaged. Cradle both reel flanges between fork tines. Never allow fork tines to touch the cable surface or reel wrap. Lower reels from a truck using a hydraulic gate, hoist or fork lift. LOWER CAREFULLY. Never drop reels. A Division of RSCC Cable Group EX-125 Rev. 6 (April 2013) East Granby, CT 20 Bradley Park Road East Granby, CT Tel: Fax: ISO 9001 REGISTERED Houston, Texas Office RSCC 2203 Timberloch Place Suite 132 The Woodlands, Texas Tel: Fax: RSCC Wire & Cable LLC A Marmon Wire & Cable Berkshire Hathaway Company
Instrumentation Cable...14-17. Power Cable...2-11. Assembly Solutions...32
Severe Cold Durability Exceeds CSA Cold Bend / Cold Impact (-0 C/-35 C) Drilling Mud Resistant Flame Retardant Certified to IEC 9-3 (33-3A) and IEEE 580 Oil Resistant Assemblies...3-33 Ester Based Mud
More informationGexol. Gexol. The Global Cable Solutions Company. Designed for safe, reliable performance in the harshest oil and gas operating environments
Gexol Gexol World Class World Class Designed for safe, reliable performance in the harshest oil and gas operating environments Power Control Instrument VFD The Global Cable Solutions Company Gexol World
More information100% EMI Emission Containment
100% EMI Emission Containment Designed for Longer Service Life Highly Flexible for Easier Handling and Faster Installation Authorized Distributor Industrial VFD Cables Index n Variable Frequency Drive
More informationCIR. Index. Gexol. Standard CIR UL Listed Type TC-ER. Crush and Impact Resistant Without External Armoring. Arctic CIR UL Listed Type TC-ER-HL*
Gexol CIR Crush and Impact Resistant Without External Armoring Passes the same stringent crush and impact testing required by UL 2225 for Type MC-HL n Available in Standard and Arctic Grade Jackets n Highly
More informationIndustrial Cable Solutions for Variable Frequency Drives
Industrial Cable Solutions for Variable Frequency Drives Tough challenges call for innovative solutions, and General Cable is your worldwide source for new products and a wide range of industry-leading
More informationLEAD FREE FIREX. Interlock Armored Cables TECK90 and MC Industrial Cables. w w w. n e x a n s e n e r g y. c o m
FIREX Interlock Armored Cables TECK90 and MC Industrial Cables LEAD FREE O V E R 1 8 0 Y E A R S O F E X P E R I E N C E 866-663-9267 w w w. n e x a n s e n e r g y. c o m Interlock Armored Cables Introduction....2
More informationCCW Continuously Corrugated Welded Cable A RMORED CAB LE FO R HAZAR D O U S LOCATI O N S
CCW Continuously Corrugated Welded Cable A RMORED CAB LE FO R HAZAR D O U S LOCATI O N S OCTOBER 2014 CCW Servicing Industrial and Specialty Applications This catalog contains in-depth information on the
More informationOutside Telephone Cable
Outside Telephone Cable Filled Core. Moisture Barrier. Description Soft copper wires insulated with high density polyethylene, foam skin or solid. Filled core, conformed by groups of pairs or by unit of
More informationCommunication, Signal & Data Cables
Communication, Signal & Data Cables Used for indoor installation and interconnection of transmission, telephone, telegraph and electronic equipment as well as media equipments www.alfanar.com Communication
More informationIEEE POWER ENGINEERING SOCIETY CHICAGO CHAPTER THE OKONITE COMPANY WEDNESDAY JANUARY 11, 2006 JIM FITZGERALD ENGINEERING LINGO
IEEE POWER ENGINEERING SOCIETY CHICAGO CHAPTER THE OKONITE COMPANY WEDNESDAY JANUARY 11, 2006 JIM FITZGERALD ENGINEERING LINGO WHEN YOU HEAR AN ENGINEER SAY A NUMBER OF DIFFERENT APPROACHES ARE BEING IMPLEMENTED
More informationKNOW YOUR OPTIONS: 69 KV XLPE POWER CABLE
Know Your Options: 69 kv XLPE Power Cable 3 material and size material is a matter of both customer preference and required current carrying capacity Copper conductor common for larger loads When both
More informationKNOW YOUR OPTIONS: 230 KV POWER CABLES
KNOW YOUR OPTIONS: 230 KV POWER CABLES 71 CONDUCTOR MATERIAL AND SIZE Conductor material is a matter of both customer preference and required current carrying capacity At 230 kv, copper is most common
More informationTFC/U-JIN Coaxial Cable Product Information Sheet Type: TU6T60-JVB
Type: TU6T60-JVB Dielectric 2nd Outer (w/optional Floodant) Series 6 Coaxial Cable Copper Clad Steel Foamed Polyethylene Dielectric Bonded AP Laminate Shield 60% Aluminum Braid "Life Time" compound AP
More informationUnarmored Variable Frequency Drive (VFD) Cable Termination Guide
Authorized Distributor Unarmored Variable Frequency Drive (VFD) Cable Termination Guide Be Certain with Belden A Step-by-Step Look at the Connection/Termination of Unarmored VFD Cables Terminating Unarmored
More informationSection 5 161 kv Power Cables
Know Your Options: 161 kv Power Cable 61 material and size material is a matter of both customer preference and required current carrying capacity Copper conductor common for larger loads When both copper
More informationwith coloured cores and overall copper screen UL/CSA... 17
CONTENT Cable Track Cables y SD 200 extremely flexible TPE/PUR data cable with coloured cores for continuous movement..... 6 y S 200 extremely flexible TPE/PUR control cable with numbered cores for continuous
More informationMarine & Shipboard Cable JIS C 3410(1999) IEC 60092-350, 353, 354, 376
T o t a l S o l u t i o n o f M a r i n e C a b l e Marine & Shipboard Cable JIS C 3410(1999) IEC 60092-350, 353, 354, 376 Marine & Shipboard cable Total Solution of Marine Cable JIS C 3410(1999), IEC
More informationYour Only Solution for All Variable Frequency Drive Applications
ASD/VFD Cable System ASDBrochure.indd 1 Your Only Solution for All Variable Frequency Drive Applications 11/2/12 9:23 AM Inadequacies in Standard VFD Cables: EMC-Electro Magnetic Compatibility Electromagnetic
More informationA quick product finder for commercial applications JUDD WIRE INC. A member of the Sumitomo Electric Industries group of companies
A quick product finder for commercial applications JUDD WIRE INC. A member of the Sumitomo Electric Industries group of companies Select, Customize, Order & Receive Products with Ease This catalog contains
More informationDIRECTCONNECT SERVICE
DIRECTCONNECT SERVICE PRE-ASSEMBLED: LEADS, GROUNDS AND STINGERS/WHIPS Save Time, Labor and Money Lead Stinger/Whip Stock Colors (Blue, Green, Red, Yellow) available Stocked genuine Lenco and Tweco Connectors
More information2012 CATALOG AEROSPACE VVIRE & CABLE INC. aerospacewire.com
* 2012 CATALOG AEROSPACE VVIRE & CABLE INC. A VV aerospacewire.com W e p r o u d l y m a n u f a c t u r e h i - t e m p w i r e & c a b l e. PLENUM CABLE. INDUSTRIAL CABLE. TRAY CABLE. MILITARY WIRE.
More informationFlexible cables for submersible products
Flexible cables for submersible products Standards SUBCAB cables complies with the following general standards: IEC 6045 (general) IEC 608 class 5 (conductor) IEC 608-- CLAUSE 9 (oil resistant) IEC 608--
More informationThe National Armored Cable Manufacturers Association Presents. Installation Standard for Types AC and MC Cables
The National Armored Cable Manufacturers Association Presents Installation Standard for Types AC and MC Cables An ANSI Standard Original document jointly produced by NECA and NACMA as Standard for Installing
More informationFLEXIBLE INDUSTRIAL CABLES H07RN-F TENAFLEX SR
FLEXIBLE INDUSTRIAL CABLES H07RN-F TENAFLEX SR Standards : CENELEC HD 22.4 NF C 32-102-4 DIN VDE 0282-1 and VDE 0282-4 BS 6007 and BS 6500 IEC 60245-4 Rated voltage Rated voltage: 450/750 V (Use up to
More informationMarineTuff Offshore and Marine Cable Solutions
Offshore and Marine Cable Solutions Belden offers the industry s largest selection of industrial cables for offshore and marine certified applications Whether you are handling oil, natural gas or petrochemicals,
More informationFlygt flexible cables
Flygt flexible cables Contents Standards General SUBCAB 4 Screened SUBCAB 6 Rubber cable type: NSSHÖU-J 7 Screened rubber cable type: NSSHÖU../E + ST 8 FGB screened rubber cable 9 PUR control cable 0 HCR
More informationGenerator DoCKInG StatIonS
Generator DOCKING STATIONS TRYSTAR Portable Power Cable Cam to cam cable extensions 2000V, 100A-400A rated to NEC table 400.5 (B) All portable power cable sold is highly flexible and UL & C-UL or CSA Listed
More informationOFFICE OF CIVIL ENGINEERING UNITED STATES COAST GUARD WASHINGTON, D.C. APRIL 1996 MARINE CABLE, POWER AND CONTROL SPECIFICATION NO.
OFFICE OF CIVIL ENGINEERING UNITED STATES COAST GUARD WASHINGTON, D.C. APRIL 1996 MARINE CABLE, POWER AND CONTROL SPECIFICATION NO. G-SEC-390E 1. SCOPE 1.1 Purpose. This specification establishes the basic
More informationSpecializing in the cable business for over 38 years, PT. SUPREME CABLE
Specializing in the cable business for over 38 years, PT. SUPREME CABLE MANUFACTURING & COMMERCE Tbk. (PT. SUCACO Tbk) has grown steadly to become a largest and leading cable manufacturer, with international
More information< SD 200 C TP Continuously flexible TPE/PUR paired data cable with coloured cores and overall copper screen... 10
CONTENT General < The Company..................................................................................... 3 Customized cables for different applications < Data / POF Cables POF-LWL and hybrid
More informationHook-Up and Lead Wire
3.1 Hook-Up and Lead Wire 3 Table of Contents Hook-Up & Lead Wire Page Introduction: UL Style & CSA Type Listings 3.2 PVC 3.3 3.8 300V, 80 C 3.3 300V, 105 C 3.4 600V, 105 C 3.5 (Type MW) MIL-W-76C-PVC:
More informationPROFIBUS cable. PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications
Data Sheet 10/63-6.47-EN Rev. D PROFIBUS cable PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications PROFIBUS PA cables Non-Ex (Hazardous) applications Ex (Hazardous) applications
More informationGlobal cable solutions for harsh environment upstream applications, offshore topside and land drilling
Global cable solutions for harsh environment upstream applications, offshore topside and land drilling Oil & gas challenges Your offshore and land drilling projects need to operate more safely and profitably.
More informationType XHHW-2 or RHH/RHW-2/USE-2 GenFree II LSZH XLPO Single Conductor
TABLE OF CONTENTS SECTION I. SUBJECT SCOPE 2 II. APPLICABLE DOCUMENTS 2 III. CONDUCTOR 3 IV. SEPARATOR 3 V. INSULATION 3 A. 3-4 B. Electrical Properties 4 C. Flame Resistance 5 D. Smoke and Halogen Testing
More informationSECTION 18370 SIGNAL WIRE AND CABLE
SECTION 18370 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for all cable and wire required for signal and signal power system wiring to wayside shelters, junction boxes, and factory
More informationCONFLEX ELECTRIC CABLE
CONFLEX ELECTRIC CABLE CONFLEX - 0.6/1kV Flexible VSD/EMC Cables Applications WW VSD/EMC cables are manufactured for use where electrical interference distorts signal transmission in electric motors. Standard
More informationTop Drive Service Loops. Conventional, Enhanced and Superior Solutions for Drilling Applications
Top Drive Service Loops Conventional, Enhanced and Superior Solutions for Drilling Applications Linking the future As the worldwide leader in the cable industry, Prysmian Group believes in the effective,
More informationSpecification SFTP CAT6 Network Cable 23AWG CU
Specification SFTP CAT6 Network Cable 23AWG CU S/FTP CAT6 Shielded S/FTP PVC Cable 23AWG 4pair Solid, Wooden drum 1000 Grey CAT6 600MHZ CM Shielded (S/FTP) Solid Cable: Our CAT6 600MHZ Shielded (S/FTP)
More informationW-2. Stranding Comparison
Wire Knowledge W-1 W-2 Stranding Comparison Conductor Coatings/Coverings PURPOSE To facilitate stripping of components applied over the conductor To prevent compound fall-in Improve solderability Prevent
More information2 8 k V, 1 / C, T R X L P E I N S U L A T E D, F L A T S T R A P S H I E L D E D C A B L E, C O M P R E S S E D S T R A N D I N G
Seattle Cit y Light 1 of 4 2 8 k V, 1 / C, T R X L P E I N S U L A T E D, F L A T S T R A P S H I E L D E D C A B L E, C O M P R E S S E D S T R A N D I N G 1. Scope This standard covers the detailed requirements
More informationServo Motor & Drive Cables
Servo Motor & Drive Cables Servo-Motor & Drive Cable Contents Servo-SM (Servo-Motor & Feedback Cables to Siemens Specifications) 970 SERVO-SM5-6FX5008-1BD.. UL/CSA/CE SHLD PVC Feedback Cable- Green 971
More informationPROFIBUS cable. for PROFIBUS-PA and -DP 10/63-6.46 EN
for PROFIBUS-PA and -DP 10/63-6.46 EN CPN 080/CPE 080-Ex PROFIBUS-PA basis cable AWG 18, 0.88 mm 2 Use For fixed installation indoor and outdoor, on racks and in conduits. Application Fieldbus cable for
More informationCOAX Cables Radio Frequency Cables
COAX Cables Radio Frequency Cables Contents Page Table of contents Pictographs General information Introduction Types and abbreviations Temparature range Construction Characteristics Special constructions
More informationUGVCL/SP/591/11KV HT AB CABLE
TECHNICAL SPECIFICATION FOR 11KV AERIAL BUNCHED CABLES FOR OVERHEAD LINES (CROSSED LINKED POLYTHENE DRY GAS CURED) 1. SCOPE This specification covers requirements of XLPE insulated, 11 KV Aerial Bunched
More informationWhy FOUNDATION Fieldbus?
Product Bulletin PB 244-R3 Fieldbus Cables Fieldbus Tye A cables rovide installation flexibility in many different environments, including outdoors and where multile or extended cable runs are required.
More informationFestoon 715 P PUR cable for flexible application in festoon systems
CABLES FOR CRANE AND CONVEYOR APPLICATIONS Festoon 715 P PUR cable for flexible application in festoon systems S AB BRÖCKSKES D-VIERSEN Festoon 715 P 1 x 16.0 mm 2 C Marking for Festoon 715 P 07150162:
More informationPETROCHEMICAL CATALOG
PETROCHEMICAL CATALOG East Granby, Connecticut Facility Introduction The Rockbestos-Surprenant Cable Corporation is a world leader in the design and manufacture of insulated high performance control, power,
More informationRoHS DATA, COAXIAL AND ELECTRONIC M.R. D A TA, C O A X I A L, ECOLGICAL Telecom Cables A N D EL E CTRON I C. Cables
RoHS DATA, COAXIAL AND ELECTRONIC D A TA, C O A X I A L, A N D EL E CTRON I C Cables Index SOLID MULTI-CONDUCTOR CABLES STRANDED MULTI-CONDUCTOR CABLES SPEAKER/ZIP WIRE THERMOSTAT CABLE FIRE ALARM CABLE
More information140 146 rue E. Delacroix / BP 1 F 91211 Draveil cedex FRANCE Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70. Issue 2 01/10/2003-2 -
Space cables Issue 2 01/10/2003-2 - C O N T E N T ESCC Qualified Products Nexans P/N ESCC SP Pages 1871-871 3901/001 359 3/8 1872-872 3901/002 358 9/14 MTV - BTV 3901/013 199 15/19 50 CIS 3902/001.01 189
More informationETHERLINE Ethernet Cable, Connectors & Tools
Ethernet Cable, ors & Tools 2 Pair 242 4 Pair 249 Industrial Ethernet ors & Tools 256 Ethernet Cable, ors & Tools ETHERNET CABLE, CONNECTORS & TOOLS Quick Select Chart 240 2 Pair 2 Pair: CAT.5/5e; Stationary
More informationdb MISER ULTRA LOW LOSS CABLE ASSEMBLIES Are you a design or test engineer fighting a challenging loss budget?
db MISER ULTRA LOW LOSS ASSEMBLIES Are you a design or test engineer fighting a challenging loss budget? Consider db Miser ultra low loss cable assemblies. High performance materials, careful attention
More informationMICROCABLES. A complete vision of your connectivity needs. Catalogue
MICROCABLES A complete vision of your connectivity needs Catalogue ELECTRONIC Filotex Introduction Application Nexans s line of microcables is designed towards the increasing requirements of electronics
More informationBRÖCKSKES D-VIERSEN PV1-F 4,0 mm BRÖCKSKES D-VIERSEN PV1-F 4,0 mm d d 2 2 C VDE-REG.-Nr. 8292 10/2009
d BRÖCKSKES BRÖCKSKES D-VIERSEN D-VIERSEN PV1-F PV1-F 4,0 mm 4,0 2 mm VDE-REG.-Nr. 2 C 8292 10/2009 s - THE COMPANY DIN EN ISO 9001 More than 60 years of experience in temperature measurement and control
More informationCable Solutions for Servo and Variable Frequency Drives (VFD)
Cable Solutions for Servo and Variable Frequency Drives (VFD) Electric drive systems with continuous torque and speed control are widespread today. They allow an optimal adjustment of the drive with respect
More informationVIPERFLEX ELECTRIC CABLE
VIPERFLEX Flexible Low Voltage Electric Cable - 0.6/1kV (Rubber insulated) H07 RN-F & H07 BN-F Single Core 2-Core 2-Core and Earth 3-Core and Earth 4-Core and Earth Multi-Core and Earth H07 RCN-F & H07
More informationGlobal cable expertise for rolling stock
Global cable expertise for rolling stock Global cable expertise for rolling stock Single and multicore Low voltage control cables Jumper cables HV roof cables (25 kv) rubber cables for power needs of locomotives
More informationCABLE GLANDS AND CONNECTORS FOR THE IEC & NEC WORLD ATEX 95 & BEYOND ATEX 95 CMP PRODUCTS. Triple Certified
IECEx & ATEX 95 CMP PRODUCTS S AND CONNECTORS FOR THE IEC & NEC WORLD ATEX 95 & BEYOND Triple Certified Single Solution Three Forms of Protection Ex d / Ex e / Ex nr N O O T H E R M A CONTENTS Leading
More informationSelf-Regulating Low Temperature Heating Cable
PDS SRL Self-Regulating Low Temperature Heating Cable Self-Regulating, Energy Efficient 16 AWG Buss Wire Circuit Lengths to 660 Feet Process Temperature Maintenance to 150 F (65 C) Maximum Continuous Exposure
More informationCorporate Profile ROYAL. MODERN ROYAL ELECTRIC Ideal Power Solution MRE ELECTRICAL, INSTRUMENTATION & COMMUNICATION SYSTEMS
Corporate Profile MODERN ROYAL ELECTRIC Ideal Power Solution ROYAL MRE ELECTRICAL, INSTRUMENTATION & COMMUNICATION SYSTEMS MAJOR STOCKIST >>> CATHODIC PROTECTION CABLES >>> LOW VOLTAGE CABLES >>> MEDIUM
More informationRF & Microwave cable assemblies C291
ERTIFIED C AS 9100 RF & Microwave cable assemblies C291 B CONTENTS Pages Introduction... B-4 Specify the right cable for your application... B-5 Finder guide cables vs insertion loss... B-6 to B-7 Flexible
More informationStandards Affecting a Premise T-1 Installation
Standards Affecting a Premise T-1 Installation The T-carrier system originated many years ago as a technology developed by AT&T. The intended use of the scheme was to increase the voice channel capacity
More informationStandard Buccaneer - Ethernet
IP6 rated compliant PUR jacket on cable Shielded system shielded coupler Shroud on RJ45 Screw coupling Rewireable flex connector PCB mounted panel connector IDC termination panel connector Earth lead version
More informationDATA SHEET SERVO LK SMS FX8PLUS SIGNAL
Application LAPP servo cables according to Siemens * (see footnote) Standard FX8008 PLUS SIGNAL are a new generation of very highly flexible screened signal (encoder and resolver)- cables (P/Ns 00277101
More informationGulf Cable & Electrical Ind. Co.
CONTENTS INTRODUCTION PRODUCT RANGE I PRODUCT DATA TABLES Irrigation 1 Coaxial s for T.V/ Satellite Antenna etc 2 Data Transmission s - 4 pair 24 AWG 3 TELEPHONE CABLES Telephone cables CCP-LAP & CCP-LAP-SS
More informationCommercial Coaxial Cable
Commercial Coaxial Cable For the Best in COMMERCIAL TV Reception Solutions! Do you require a Digital TV reception system for your next project? Matchmaster can supply For The Best Design and supply of
More informationFire Resistant Cables
109/4 Fire Resistant Cables SR 114H Standard - SR 114E Enhanced BS 5839-1 BS 7629-1 BS 6387 BS 8434-1/2 BS 6425 BS 7622 EN 50200 World-wide recognized high quality cables Firecel SR114 are used in: Data
More informationCable Products HONEYWELL SECURITY & CUSTOM ELECTRONICS. Honeywell's Genesis Series provides a full range
HONEYWELL SECURITY & CUSTOM ELECTRONICS Cable Products Honeywell's Genesis Series provides a full range of low voltage cables for security, fire, sound, voice and data, video, structured cabling and other
More informationFlexible Control Cables
Works photo: KUKA Flexible Control Cables A Flexible Control Cables Since generations people try to build machines and plants which shall take on different functions. To raise, sink, slide, drill, transport
More informationWest Penn Wire. Access Control Systems and Cables WEST PENN WIRE CABLE WITH CONFIDENCE
West Penn Wire Access Control Systems and Cables Access Control Cables AWG Size CARD READER CABLES # of Cond. CMR Shielded CMP Shielded CMR Unshielded CMP Unshielded 22 4 3241 253241B 241 25241B 22 6 3270
More informationEcoFlex Cable. Smaller. Lighter. Tougher. 100% Recyclable.
EcoFlex Cable Smaller. Lighter. Tougher. 100% Recyclable. Total Performance, Completely Recyclable EcoFlex cable is Alpha Wire s newest innovation in control cabling. A true engineering breakthrough, EcoFlex
More informationThe Instrumentation Cable Experts
1 The Instrumentation Cable Experts Facilities Head office & factory 1300 Industrial Boulevard Mt Pleasant, Texas 75455, USA www.dekoroncable.com Stocking Centres USA Mt Pleasant and Houston Singapore
More informationThe Contractor shall furnish and install all shielded power cable suitable for use on this project.
Section 16122 PRIMARY POWER CABLES PART 1 GENERAL: WORK INCLUDED The Contractor shall furnish and install all shielded power cable suitable for use on this project. RELATED WORK Section 16020: Tests SUBMITTALS
More informationBasic Cable Assemblies DELIVERING QUALITY SINCE 1952.
Basic Cable Assemblies DELIVERING QUALITY SINCE 1952. Cable Types Cable Types Hook-up & Lead Wire Most Basic 2 Cable Types Cable Types Twisted Pair Cable A type of cable that consists of two independently
More informationIntroduction. Benefits of Variable Frequency Drives
Introduction Choosing the Right Cable for Your Variable Frequency Drive (VFD) System By Brian Shuman, Senior Product Development Engineer, Belden Inc. Table of Contents Introduction...1 Benefits of Variable
More informationMESSENGERS FOR AERIAL CABLE
MESSENGERS FOR AERIAL CABLE COPPERWELD - EHS, 30% CONDUCTIVITY MES(size)CUWELD Size O.D. Stranding Breaking Strength Wgt./Mft. MES1/4CUWELD 1/4".242 7 #12 5,783 lbs. 128 MES5/16CUWELD 5/16".306 7 # 10
More informationFOREWORD ONE OF THE WORLD S BIGGEST COMPANIES IN THE SECTOR.
OFFSHORE CABLES FOREWORD ONE OF THE WORLD S BIGGEST COMPANIES IN THE SECTOR. General Cable Corporation is one of the world s leading cable manufacturing companies. In its work it has contributed decisively
More informationTELE-FONIKA CABLE AMERICAS
TELE-FONIKA CABLE AMERICAS TELE-FONIKA CABLE AMERICAS (TF KABLE) is a US firm with corporate offices and main facility located in Bolingbrook, IL and is a wholly owned subsidiary of Tele-Fonika Kable SA.
More informationSerial Data Grade Cables
VGA INPUT MONITOR OUT VGA INPUT MONITOR OUT 3.5mm STEREO MINI 3.5mm STEREO MINI L R Audio L R Audio AUDIO INPUTS + - + - AUDIO INPUTS + - + - AMPLIFIED OUTPUT 4/8 ohm COM 70V 100V AMPLIFIED OUTPUT 4/8
More informationCable Tray Selection-
Cable Selection- For allowable cable types see the Appendix page A-9. The following guidelines are based on the 2002 National Electrical Code, Article 392. I) Number of Multiconductor Cables rated 2000
More informationTri-Rated Flexible PVC Equipment Wire
Application: High temperature, flame retardant wire designed for use in the switch control, relay and instrumentation panels of power switchgear and for purposes such as internal connectors in rectifier
More informationProtection Systems. A UTC Fire & Security Company F-73-01. Linear Heat Detector FEATURES DESCRIPTION APPLICATIONS BENEFITS
Effective: May 2007 AlarmLine TM R Protection Systems Linear Heat Detector A UTC Fire & Security Company F-73-01 FEATURES Integrating Type Linear Heat Detector Analog Sensing Field Adjustable Alarm Set
More informationCoaxial Cables for Medium-Frequency Applications
Coaxial Cables for Medium-Frequency Applications Coaxial Cables for Medium-Frequency Applications Introduction Telecommunications technology is moving forward rapidly and the need for fast and reliable
More informationCABLE SPECIFICATION CAN CAB RJ45-SUBD9
CABLE SPECIFICATION All technical information contained in this document is the exclusive property of STI and may neither be used nor disclosed without its prior written consent. AAV 33801 1/8 Connector
More informationSTABILOY BRAND FEEDER SOLUTIONS ASSISTED LIVING FACILITIES
STABILOY BRAND FEEDER SOLUTIONS ASSISTED LIVING FACILITIES Introduction General Cable understands that assisted living facilities require complex building designs that must address a wide range of systems
More informationThe Quality Connection. Cable Solutions for Mobile Networks Business Unit Telecom
The Quality Connection Cable Solutions for Mobile Networks Business Unit Telecom Connection Technology for Wireless Communication Systems A consistent focus on the market, in-depth sector and product knowledge,
More information450-750 VOLTS - Copper conductor PVC insulated SSA 1320, IEC 60227 & BS 6004 HO 7V - U With Solid Conductor - TYPE 60227 IEC 01. Insulation Thickness
450 50 VOLTS Copper conductor PVC insulated SSA 320, IEC 6022 & BS 6004 HO V U With Solid TYPE 6022 IEC 0 For internal wiring equipment rated voltage up to 000 V AC and up to 50 V to earth. Catalogue Number
More informationSecurity & Control Cables
Security & Control Cables Our multi-conductor cables are manufactured in a wide variety of gage sizes, shielding configurations and jacketing materials including plenum, riser and general purpose. Applications
More informationSPEC 55. Wire and cable. Applications. SPEC 55PC wire and cable insulation system. Features and benefits. Physical characteristics
SPEC 55 Wire and cable Applications SPEC 55 wire is insulated with modified radiation cross-linked ETFE polymer. It has a temperature rating of -65 C to 200 C continuous using a silver plated copper conductor,
More informationSound, Alarm & Security Cable 7
Electronics Sound, Alarm & Security Cable 7 Index Page The sound and security industry in the United States has grown from a simple and unsophisticated business, begun some 45 years ago, to one which has
More informationTraveling Cable for Crane. www.tmc-cable.com. www.tmc-cable.com
Head Office / Ipjang Factory 443, Yeongok-gil, Ipjang-myeon, Seobuk-gu, Cheonan-si, Chungcheongnam-do, Korea Tel. +82-41-589-6500 Fax. +82-41-589-6400 Bukmyeon Factory 5, Myungduk 1-gil, Buk-myeon, Dongnam-gu,
More informationMarmon Engineered Wire & Cable is a unique group of 13 major cable manufacturers whose synergy offers tremendous breadth of product offering,
Marmon Engineered Wire & Cable is a unique group of 13 major cable manufacturers whose synergy offers tremendous breadth of product offering, advanced R&D, continuous innovation and the financial strengths
More informationMEDIUM VOLTAGE POWER CABLES
MEDIUM VOLTAGE POWER CABLES CONTENTS 1 GENERAL INTRODUCTION 4 TECHNICAL INFORMATION 15 25 35 45 Single Core XLPE Insulated PVC Sheathed Cables UNARMOURED CABLES COPPER UNARMOURED CABLES ALUMINUM ALUMINUM
More informationAll Wires and Cables Are Not Created Equal
All Wires and Cables Are Not Created Equal When comparing life cycle costs for wires and cables in wind systems, consider the specific applications, cost per failure and dielectric losses to determine
More informationInternational Electrotechnical Commission Standards
International Electrotechnical Commission Standards Standard IEC 60028 IEC 60038 IEC 60050-461 IEC 60055-1 IEC 60055-2 IEC 60092-101 IEC 60092-350 IEC 60092-351 IEC 60092-352 IEC 60092-353 IEC 60092-354
More informationDIVISION 26 - ELECTRICAL SECTION 26 05 20 CABLES FOR INSTRUMENTATION
DIVISION 26 - ELECTRICAL PART 1 - GENERAL 1.01 SUMMARY A. Section Includes 1. Instrumentation Cables 1.02 SUBMITTALS A. Submit in accordance with requirements of Section 01 33 00. B. Product Data: Submit
More informationSUBJECT: NO MORE 300 VOLTS IN PLTC PRINT LEGEND
Belden Electronics Division P.O. Box 1980 Richmond, Indiana 47375-1980 2200 U.S. Highway 27 South Richmond, Indiana 47374-7279 Telephone: 765 983 5200 Facsimile: 765 983 5825 SUBJECT: NO MORE 300 VOLTS
More information6000 Series Buccaneer
Robust, instant connections for harsh environments 6000 Series Buccaneer - circular connectors that combine the ease of use of a push/pull coupling mechanism with proven environmental sealing. Available
More informationCABLE 101. The Basics of Wire & Cable. Copyright 2007, Belden Inc.
CABLE 101 The Basics of Wire & Cable Copyright 2007, Belden Inc. KEY TERMS Insulations Jacket Capacitance Attenuation Velocity of propagation Dielectric strength Dielectric constant Working voltage Elongation
More informationCABLES FOR PHOTOVOLTAIC SOLAR ENERGY INSTALLATIONS FOR CLEAN ENERGY
CABLES FOR PHOTOVOLTAIC SOLAR ENERGY INSTALLATIONS FOR CLEAN ENERGY One Company Connecting The World POWERFUL PRESENCE PRODUCTS PERFORMANCE PEOPLE General Cable has been a wire and cable innovator for
More informationMicrophone and Musical Instrument Cable Overview
B R I L L I A N C E B R O A D C A S T C A B L E S 19.3 Microphone and Musical Instruent Cable Overview Flexible Microphone Cables Belden icrophone cable is used for connecting low level icrophones or usical
More information