Data Sheet 10/63-6.47-EN Rev. D PROFIBUS cable PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications PROFIBUS PA cables Non-Ex (Hazardous) applications Ex (Hazardous) applications
PROFIBUS cable PROFIBUS DP cable (solid) M10773 Application M10775 (Example Sketch) Internet NDC110-NO, NDC110-EX Standard zero halogen fieldbus cable for PROFIBUS DP/FMS and FIP, suitable for 9-pin SUB-D [IP20] and M12 [IP67] connectors. [FB-02YS(St+Ce)H] Recommended for indoor and outdoor installation, in dry and wet locations, on racks, on trys and in Not suitable for direct burial. Also especially in locations where the low smoke, zero halogen and flame retardant characteristics are important (e. g. public buildings, hospitals, power stations etc.). http://www.abb.com/fieldbus Standard IEC 61158 Part 2 Classification Typ A Interface RS 485(-IS) Conductor plain annealed copper wire, solid AWG 22/1 0.33 mm 2, ø 0.65 mm Insulation foamed polyethylene with skin layer Color code Screen Outer sheath Cable marking a(n)-core: green, b(p)-core: red plastic coated aluminum tape, metallic surface outside in contact with a tinned copper drain wire and tinned copper wire braid Low smoke, zero halogen flame retardant compound LSZH, color: violet (NDC110-NO), blue [IS] (NDC110-EX) FIELDBUS CABLE IEC 61158-2 150 Ω PLTC PROFIBUS FMS/DP 1 PR 22 AWG OS (UL) 75 C SUN RES E107687 length marking Overall diameter 7.9 ±0,5 mm Weight approx. 70 kg/km Max. pulling tension 35 N Min. bending radius 7.5 x cable overall diameter Temperature range -40... 75 C during operation, -5... 50 C during installation UV resistant UL 1581 article 1200 Oil resistant ICEA S-73-532 (Test temperature 60 C; duration 4 h. Retention: min. 60 % of tensile strength/min. 60 % of elongation) Flame propagation Test on single cable: UL 13 (vertical tray), Test on bunched cable: IEC 60332-3-24 (Cat. C) Smoke density low, IEC 61034-1 and 2 (L.T. > 60%) Halogen free yes, IEC 60754-1, 0 % Degree of acidity of gases IEC 60754-2 (ph 4.3, c 10 μs/mm) Limiting Oxygen Index (LOI) ASTM D 2863, (min. 30 %) Explosion protection (NDC110-EX only) for Ex i applications [IS], Class I / II Division 2 acc. to NEC 501.10(B) and NEC 502.10(B) or Zone 1 / 2, Group II, acc. 60079-14. FISCO-approval Approval CE, UL (listed as PLTC acc. to UL 13) 2 10/63-6.47-EN Rev. D PROFIBUS cable
PROFIBUS DP cable (solid) M10773 NDC110-NO, NDC110-EX Electrical properties at 20 C Conductor resistance (Loop) Screen resistance Attenuation at 0.25 / 0.625 / 1.25 / 3.125 / 16 MHz Inductance Mutual capacitance Capac. unbalance to earth Impedance at 3 MHz Test voltage (Core / core and core / screen) Operating voltage max. 110 Ω/km nom. 12 Ω/km nom. 6 / 9 / 12 / 18 / 40 db/km nom. 0.9 mh/km max. 30 nf/km max. 1.5 nf/km 150 ±15 Ω 1500 V max. 300 V PROFIBUS cable 10/63-6.47-EN Rev. D 3
PROFIBUS cable PROFIBUS PA cable Application M10772 (Example Sketch) Internet NPC080-NO, NPC080-EX NPC150-NO, NPC150-EX NPC250-NO, NPC250-EX Standard fieldbus cable for PROFIBUS Long-distance fieldbus cable for PROFIBUS PA with additional power supply for PA with additional power supply for the the devices, cable with low voltage drop along the line. devices, suitable for insulation [FB-2Y(St+Ce)Y-fl] displacement connections or M12 connectors. [FB-02YS(St+Ce)Y-fl] Recommended for indoor and outdoor installation, in dry and wet locations, on racks, on trys and in Not suitable for direct burial. http://www.abb.com/fieldbus Standard IEC 61158 Part 2 Classification Typ A Interface MBP-LP(-IS), IEC 61158 Conductor plain annealed copper wire, stranded AWG 18/7 0.88 mm 2 AWG 16/7 1.3 mm 2 AWG 14/7 2.1 mm 2 Insulation foamed polyethylene with skin layer polyethylene Color code Screen Outer sheath Cable marking a(-)-core: green, b(+)-core: red plastic coated aluminium tape, metallic surface outside in contact with a tinned copper drain wire and tinned copper wire braid polyvinyl chloride PVC, color: black (NPCnnn-NO), blue [IS] (NPCnnn-EX) FIELDBUS CABLE IEC 61158-2 100 Ω PLTC PROFIBUS PA 1 PR xx AWG OS (UL) 75 C SUN RES E107687 length marking Overall diameter 7.6 ±0,4 mm 9.4 ±0,6 mm 11.5 ±1.0 mm Weight approx. 75 kg/km approx. 114 kg/km approx. 166 kg/km Max. pulling tension 90 N 130 N 200 N Min. bending radius 7.5 x cable overall diameter Temperature range -40... 75 C during operation, -5... 50 C for installation UV resistant UL 1581 article 1200 Oil resistant ICEA S-73-532 Flame propagation Test on single cable: UL 13 (vertical tray), Test on bunched cable: IEC 60332-3-24 (Cat. C) Smoke density Halogen free HCL emission IEC 60754-1, max. 17 % Oxygen index of outer sheath ASTM D 2863 (min. 30 %) Explosion protection (NPCnnn-EX only) for Ex i applications [IS], Class I / II Division 2 acc. to NEC 501.10(B) and NEC 502.10(B) or Zone 1 / 2, Group II, acc. to IEC 60079-14. FISCO approval FISCO not for passive components Approval CE, UL (listed as PLTC acc. to UL 13) 4 10/63-6.47-EN Rev. D PROFIBUS cable
PROFIBUS PA cable NPC080-NO, NPC080-EX NPC150-NO, NPC150-EX NPC250-NO, NPC250-EX Electrical properties at 20 C Conductor resista. max. 43.6 Ω/km max. 28.5 Ω/km max. 17.9 Ω/km (Loop) (R c ) Screen resistance nom. 12 Ω/km Attenuation at 39 khz max. 3.0 db/km Inductance (L c ) nom. 0.7 mh/km Mutual capacitance (C c ) nom. 60 nf/km Capac. unbalance to max. 4 nf/km earth Impedance 100 ±20 Ω Propagation delay max. 1.7 μs/km change (7.9 khz 39 khz) Test voltage 1500 V (Core / core and core / screen) Operating voltage max. 300 V PROFIBUS cable 10/63-6.47-EN Rev. D 5
PROFIBUS cable Ordering information PROFIBUS DP cable Catalog No. NDC110-NO 65 m (79260301) 9890140 PROFIBUS DP cable solid, violet, 2 x 0.33 mm 2 (AWG22/1), Type A. 330 m (79260301) (Note 1) 9890141 PROFIBUS DP cable solid, violet, 2 x 0.33 mm 2 (AWG22/1), Type A. 1000 m (79260301) (Note 1) 9890142 PROFIBUS DP cable solid, violet, 2 x 0.33 mm 2 (AWG22/1), Type A. NDC110-EX 65 m (79260302) 9890143 PROFIBUS DP cable solid, blue!, 2 x 0.33 mm 2 (AWG22/1), Type A, for intrinsic safety applications (Ex i). 330 m (79260302) (Note 1) 9890144 PROFIBUS DP cable solid, blue!, 2 x 0.33 mm 2 (AWG22/1), Type A, for intrinsic safety applications (Ex i). 1000 m (79260302) (Note 1) 9890145 PROFIBUS DP cable solid, blue!, 2 x 0.33 mm 2 (AWG22/1), Type A, for intrinsic safety applications (Ex i). Note 1: incl. no-return cable drum 6 10/63-6.47-EN Rev. D PROFIBUS cable
PROFIBUS PA cable Catalog No. NPC080-NO 65 m (76770101) 9890130 PROFIBUS PA cable, black, 2 x 0.88 mm 2 (AWG18/7), Type A. Loop resistance 43.6 Ω/km, UL approval, incl. special drain wire, for fixed installation indoor and outdoor, on racks and in 330 m (76770101) (Note 1) 9890131 PROFIBUS PA cable, black, 2 x 0.88 mm 2 (AWG18/7), Type A. Loop resistance 43.6 Ω/km, UL approval, incl. special drain wire, for fixed installation indoor and outdoor, on racks and in 1000 m (76770101) (Note 1) 9890132 PROFIBUS PA cable, black, 2 x 0.88 mm 2 (AWG18/7), Type A. Loop resistance 43.6 Ω/km, UL approval, incl. special drain wire, for fixed installation indoor and outdoor, on racks and in NPC150-NO 1000 m (79290101) (Note 1) 9890133 PROFIBUS PA cable, black, 2 x 1.3 mm 2 (AWG16/7), Type A. Loop resistance 28.5 Ω/km, UL approval, incl. special drain wire, for fixed installation indoor and outdoor, on racks and in NPC250-NO 1000 m (79290103) (Note 1) 9890138 PROFIBUS PA cable, black, 2 x 2.1 mm 2 (AWG14/7), Type A. Loop resistance 17.9 Ω/km, UL approval, incl. special drain wire, for fixed installation indoor and outdoor, on racks and in NPC080-EX 65 m (76770100) 9890134 PROFIBUS PA cable, blue, 2 x 0.88 mm 2 (AWG18/7), Type A, for intrinsic safety applications (Ex i). Loop resistance 43.6 Ω/km, UL approval, incl. special drain wire, for fixed installation indoor and outdoor, on racks and in 330 m (76770100) (Note 1) 9890135 PROFIBUS PA cable, blue, 2 x 0.88 mm 2 (AWG18/7), Type A, for intrinsic safety applications (Ex i). Loop resistance 43.6 Ω/km, UL approval, incl. special drain wire, for fixed installation indoor and outdoor, on racks and in 1000 m (76770100) (Note 1) 9890136 PROFIBUS PA cable, blue, 2 x 0.88 mm 2 (AWG18/7), Type A, for intrinsic safety applications (Ex i). Loop resistance 43.6 Ω/km, UL approval, incl. special drain wire, for fixed installation indoor and outdoor, on racks and in NPC150-EX 1000 m (79290100) (Note 1) 9890137 PROFIBUS PA cable, blue, 2 x 1.3 mm 2 (AWG16/7), Type A, for intrinsic safety applications (Ex i). Loop resistance 28.5 Ω/km, UL approval, incl. special drain wire, for fixed installation indoor and outdoor, on racks and in NPC250-EX 1000 m (79290102) (Note 1) 9890139 PROFIBUS PA cable, blue, 2 x 2.1 mm 2 (AWG14/7), Type A, for intrinsic safety applications (Ex i). Loop resistance 17.9 Ω/km, UL approval, incl. special drain wire, for fixed installation indoor and outdoor, on racks and in Note 1: incl. no-return cable drum PROFIBUS cable 10/63-6.47-EN Rev. D 7
Contact us ABB Automation GmbH Service Instrumentation Kallstadter Straße 1 68309 Mannheim, Germany Customer service center: +49 (0)180 5 222 580 * E-Mail: automation.service@de.abb.com www.abb.com * 14 cents/minute from German landlines, max. 42 cents/minute from mobiles. Note We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents - in whole or in parts is forbidden without prior written consent of ABB. 10/63-6.47-EN Rev. D 11.2012 Copyright 2012 ABB All rights reserved 3KXN647000R1001 Sales Service