1 Standards Affecting a Premise T-1 Installation The T-carrier system originated many years ago as a technology developed by AT&T. The intended use of the scheme was to increase the voice channel capacity within their central offices. By the late 80 s it became apparent that the demand from subscribers for bandwidth greater than 56K was becoming a reality. The extension of the T-carrier system into the subscriber network was a natural. The technology having already been developed, the migration to the premise was about to evolve. As T-1 signaling began to migrate outward from the central office, it became evident that standards would be required to help maintain the integrity of the T-carrier system. ANSI accepted the chore and by the late 80 s a number of ANSI T1 standards had been developed and published. From the installer s perspective, two of these standards hold particular relevance. *ANSI T1.403 Carrier-to-Customer Installation - DS1 Metallic Interface *ANSI T1.102 for Telecommunications Digital Hierarchy Electrical Interfaces The content of T1.102 is primarily aimed at the signal delivered from the T-carrier to the customer interface (premise demarc). The content of T1.403 is aimed primarily at the signal and the physical layer to and from the demarc and the CPE (customer premise equipment). More specifically, only to and from the very first piece of CPE. This may be a CSU, DSU, IAD, or router. T1.403 specifically states that all wiring beyond that point (inward to the remaining CPE) should be as specified by the equipment manufacturer. In choosing the proper cable to extend the T-line (demarc extension cable) these coordinated documents call out specific physical and electrical requirements which must be met in the installation. These are summarized as follows: *Balanced pairs, 22 AWG, 100 Ohm impedance. *T-carrier to complete the demarc in RJ48 jack configurations. *T extension to be pinned in plugs configured in RJ48 C or X. (See below for plug pin-out.) Certain D.B. connectors are authorized but rarely used. *Loss budget (attenuation) allotted for this cable section should be 5.5 db. This value translates to about 1,000 feet of properly designed cable without the need for repeaters. This distance will often eliminate the need for costly demarc relocations.
2 Pin-Outs Terminating in an 8-pin modular plug is specified in ANSI T USOC RJ48 pinning is required. Step 1 Using a safety razor blade, utility knife, or similar tool, ring the plastic outer sheath approximately 1-1/2 inches from the end. Remove the 1-1/2 inch slug from the construction. The two individually shielded pairs are now exposed. (Note: If the blade modestly nicked the tape and even the insulation, continue anyway. These will be removed in future steps.) Step 2 Remove all tapes flush with the jacket line. (Tip: A simple nick at the lip of each tape will permit easy tearing around the film. This is a very simple process.) You should now have a white x orange pair and a white x blue pair exposed. Step 3 The insulation system of this construction is made up of a dual layered composite. Removing the outer layer (foam) will leave the inner insulation behind. Remove the outer insulation of all four leads leaving the inner insulation adhered to the copper wire. The trick is to cut the outer layer without injuring the inner layer. Inexpensive insulation strippers are best suited for this step. Preferably the design will permit a depth setting to be adjusted and locked with the tool. If the setting is by AWG, start with 18 AWG as the setting. If the tool uses a non-indexed setting, a trial and error approach may be necessary. In either event, the removal process must be performed using a pull direction in a straight line with the cable s construction. If the pull direction is at an angle, the inner insulation is at risk.
3 Step 4 Quabbin Wire & Cable suggests the use of modular plugs that include a load bar (however there are plugs without a load bar that are popular connectors). This type of plug GREATLY reduces termination time, frustration, and errors. The two drains may be twisted together and inserted through the same position. The load bar accommodates quick, precise arrangement of leads and drains prior to insertion into the plug cavity. The pin out (color code arrangement) for USOC connector RJ48C is as shown in the load bar figure. The jack at the demarc expects to see this arrangement. Step 5 Slide the loaded load bar toward and flush with the jacket. Measuring from the jacket s edge, cut the extended leads and drains straight across and evenly leaving 5/8 inch. Step 6 Slip the load bar outward toward the end of the cut leads. Stop the load bar just short of the immediate end. (Note: The purpose of the load bar is to aim the leads so that they enter the plug cavity precisely positioned to pass through to the correct pin positions.)
4 Step 7 With the plug s release trigger positioned downward, and the orange conductor positioned leftmost, press the cable with load bar into the plug cavity causing the leads to now extend to the far end of the plug nose. When correctly positioned: 1. The conductors should extend to the end of the plug 2. The load bar should be firmly seated so as to resist further movement in either direction 3. The outer jacket should enter the plug cavity about 1/4 inch Step 8 Using a mod plug crimping tool containing an 8-pin compression die, press the assembled cable and modular connector into the die. Manually complete the mating of the cable and plug by compressing the handles through a complete cycle. The pins should now have continuity with the conductors and the jacket should now be held in place by an included strain relief. Remove the assembly from the crimping tool. This terminated end is ready for installation at the demarc point. Quabbin s Solution Quabbin Wire & Cable has designed part number 9720 to carry this signal. It is a true T-1 demarc extension cable. Cable specification information is shown below. Ask your preferred distributor for it by name and part number.
5 PN ) CONSTRUCTION: NOM. DIA. CONDUCTOR: 22 AWG SOLID TINNED COPPER.025" INSULATION: TWO LAYER COMPOSITE POLYOLEFIN.020 WALL THICKNESS.065" PAIRS: COLOR CODED SINGLES TWISTED WITH FILLERS INTO PAIRS WRAPPED WTH AN ALUMINUM POLYESTER FOIL SHIELD (FOIL OUT) 100% COVERAGE PER PAIR. 24 AWG SOLID TINNED COPPER DRAIN EACH PAIR..133" ISOLATOR: EACH PAIR SHALL BE ELECTRICALLY ISOLATED FROM EACH OTHER WITH A POLYESTER TAPE WRAP.136 CABLE: (2) SHIELDED PAIRS PULLED IN STRAIGHT.136" X.272" JACKET: POLYVINYLCHLORIDE, BEIGE,.022" NOM. WALL THICKNESS.178" X.315" 2) PHYSICAL PROPERTIES: TEMPERATURE RATING, MAX. 60 C WT./M', NOM., NET LBS. 3) ELECTRICAL CHARACTERISTICS: CAPACITANCE, MUTUAL DIELECTRIC WITHSTANDING, MIN VOLTAGE RATING, MAX. NEXT, TYPICAL D.C. RESISTANCE, MAX. PER ASTM B258 IMPEDANCE, CHARACTERISTIC, NOM RETURN LOSS, TYPICAL ATTENUATION: 15 PF/FT. AT 1 MHZ 1500V RMS 300V GREATER THAN 60 DB; 500KHZ TO 3.5 MHZ 16.6 OHMS/M' OHMS FROM 500 KHZ TO 3.5 MHZ (+/- 10 OHMS AT.772 MHZ AND AT MHZ) GREATER THAN 30DB; 500 KHZ TO 3.5 MHZ 4) AGENCY APPROVALS: NEC (UL) TYPE CMR CEC C(UL) TYPE CMR 5) APPLICATION: T1: LEVELS 1,1A AND 1C INTERCONNECTION COMPLIES WITH ANSI T1.403 CARRIER-TO-CUSTOMER INSTALLATION - DS1 METALLIC INTERFACE AT A MAXIMUM LENGTH OF 200M (655FT). RoHS COMPLIANT MATERIALS. NOTE: THIS CONSTRUCTION IS UNIQUELY DESIGNED TO FIT MOST POPULAR RJ-45 CONNECTORS WHEN THE OUTER PRIMARY INSULATION IS REMOVED. 6) PRINT: QUABBIN DATAMAX 100 OHM T1 (DS1) CABLE P/N 9720R -- TYPE CMR (UL) C(UL) 22 AWG SHIELDED
6 RoHS -- (LOT DESIGNATOR) (SEQUENTIAL FOOTAGE) 7) COLOR CODE: 1. ORANGE X WHITE/ORANGE 2. BLUE X WHITE/BLUE 8) PACKAGING: TO BE PACKAGED AS PER QWC'S STANDARD PACKAGING It is important that the termination be performed using the manufacturer s recommended crimping tools, procedures, and hardware. The following connectors are suggested. Contact the manufacturer for availability and details. Suggested Plug Manufacturer Connector Part Numbers Sentinel Connector Systems* ( ) Stewart Connector Systems ( ) 940SP3088OB Tyco Electronics (AMP) ( ) *This particular connector system does NOT include a load bar; it is however a popular proven connector.
Communication, Signal & Data Cables
Communication, Signal & Data Cables Used for indoor installation and interconnection of transmission, telephone, telegraph and electronic equipment as well as media equipments www.alfanar.com Communication
Jack to Jack adapters Plug to Plug U-Link connectors PCB Right angle plastic PCB Right angle - metal. Ordering Codes
BNC 75Ω RF CONNECTORS BNC 75Ω RF CONNECTORS To meet the need for higher performance, impedance matched cable interconnections, Amphenol offers a full line of 75 ohm BNC connectors. These connectors can
1394 locking cables. Your locking cables for AVT IEEE 1394 cameras
Your locking cables for AVT IEEE 1394 cameras AVT locking cables are ideal for connection of IEEE 1394 cameras in any industrial application. The high quality cables guarantee low damping and best signal
Network Engineers Everywhere:
Network Engineers Everywhere: Relax Your Minds Not Your Standards DataMax Commercial Ethernet Patch Cable The Strongest Link. DataMax Commercial Ethernet Patch Cable The Strongest Link. DataMax Patch Cable
114-22008. 8-Position Cat5e (EMT) Modular Plug Connectors. Application Specification
Application Specification 114-22008 02/May/2008 Rev H 8-Position Cat5e (EMT) Modular Plug Connectors NOTE All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are
400 Series - Mini USB Buccaneer
IP68 Sealed IP68 rated USB V2.0 performance Plug and play capability Shielded system Overmoulded cables Screw coupling PCB versions Dust and waterproof to EN60529 Data rates up to 480Mbs Hot pluggable,
RoHS DATA, COAXIAL AND ELECTRONIC M.R. D A TA, C O A X I A L, ECOLGICAL Telecom Cables A N D EL E CTRON I C. Cables
RoHS DATA, COAXIAL AND ELECTRONIC D A TA, C O A X I A L, A N D EL E CTRON I C Cables Index SOLID MULTI-CONDUCTOR CABLES STRANDED MULTI-CONDUCTOR CABLES SPEAKER/ZIP WIRE THERMOSTAT CABLE FIRE ALARM CABLE
Serial Data Grade Cables
VGA INPUT MONITOR OUT VGA INPUT MONITOR OUT 3.5mm STEREO MINI 3.5mm STEREO MINI L R Audio L R Audio AUDIO INPUTS + - + - AUDIO INPUTS + - + - AMPLIFIED OUTPUT 4/8 ohm COM 70V 100V AMPLIFIED OUTPUT 4/8
ULTIMATE SNAP-N-SEAL
ULTIMATE SNAP-N-SEAL F Series Compression Connectors Thomas & Betts introduces the Ultimate Snap-N-Seal Compression Connector, the newest addition to the Snap-N-Seal system. Look for the classic design
Directory chapter 04
M Directory chapter 04 D-Sub Mixed subminiature D connectors New Page D-Sub mixed connector system general information................... 04.02 Contact arrangements............................................
HIGH SPEED COMMUNICATIONS PLENUM CABLE CATEGORY 5e CMP FEP JACKETED, PVC-FREE UNSHIELDED TWISTED PAIR (UTP)
Cable Specification Category 5e CMP HIGH SPEED COMMUNICATIONS PLENUM CABLE CATEGORY 5e CMP FEP JACKETED, PVC-FREE UNSHIELDED TWISTED PAIR (UTP) This cable specification complies with the electrical transmission
Broadcast and Commercial AV Cabling MASTER CATALOG
Broadcast and Commercial AV Cabling MASTER CATALOG Clark Wire & Cable 408 Washington Blvd. Mundelein, IL 60060 800-222-5348 toll free 847-949-9944 local 847-949-9595 fax www.clarkwire.com Specifications
Specification SFTP CAT6 Network Cable 23AWG CU
Specification SFTP CAT6 Network Cable 23AWG CU S/FTP CAT6 Shielded S/FTP PVC Cable 23AWG 4pair Solid, Wooden drum 1000 Grey CAT6 600MHZ CM Shielded (S/FTP) Solid Cable: Our CAT6 600MHZ Shielded (S/FTP)
ETHERLINE Ethernet Cable, Connectors & Tools
Ethernet Cable, ors & Tools 2 Pair 242 4 Pair 249 Industrial Ethernet ors & Tools 256 Ethernet Cable, ors & Tools ETHERNET CABLE, CONNECTORS & TOOLS Quick Select Chart 240 2 Pair 2 Pair: CAT.5/5e; Stationary
TFC/U-JIN Coaxial Cable Product Information Sheet Type: TU6T60-JVB
Type: TU6T60-JVB Dielectric 2nd Outer (w/optional Floodant) Series 6 Coaxial Cable Copper Clad Steel Foamed Polyethylene Dielectric Bonded AP Laminate Shield 60% Aluminum Braid "Life Time" compound AP
Cable Products HONEYWELL SECURITY & CUSTOM ELECTRONICS. Honeywell's Genesis Series provides a full range
HONEYWELL SECURITY & CUSTOM ELECTRONICS Cable Products Honeywell's Genesis Series provides a full range of low voltage cables for security, fire, sound, voice and data, video, structured cabling and other
MICRO SFP+ CONNECTOR & CABLE ASSEMBLY
MICRO SFP+ CONNECTOR & CABLE ASSEMBLY micro SFP+ Connector and Cable Assembly TE Connectivity s (TE) micro SFP+ connector and cable assembly empower you to dream big when designing your communication system.
Rutenbeck Network Connection Box Cat. 5, shielded. Cable installation. UAE Connection Box Cat. 5 Operating Instructions.
Rutenbeck Network Connection Box Cat. 5, shielded 1-gang, 1 x 8-pole Order No.: 0180 00 2-gang, 2 x 8-pole Order No.: 0178 00 1-gang, (especially for channel construction) Order No.: 0802 00 2-gang, (especially
CABLE SPECIFICATION CAN CAB RJ45-SUBD9
CABLE SPECIFICATION All technical information contained in this document is the exclusive property of STI and may neither be used nor disclosed without its prior written consent. AAV 33801 1/8 Connector
DIVISION 26 - ELECTRICAL SECTION 26 05 20 CABLES FOR INSTRUMENTATION
DIVISION 26 - ELECTRICAL PART 1 - GENERAL 1.01 SUMMARY A. Section Includes 1. Instrumentation Cables 1.02 SUBMITTALS A. Submit in accordance with requirements of Section 01 33 00. B. Product Data: Submit
West Penn Wire. Access Control Systems and Cables WEST PENN WIRE CABLE WITH CONFIDENCE
West Penn Wire Access Control Systems and Cables Access Control Cables AWG Size CARD READER CABLES # of Cond. CMR Shielded CMP Shielded CMR Unshielded CMP Unshielded 22 4 3241 253241B 241 25241B 22 6 3270
DATA SHEET SERVO LK SMS FX8PLUS SIGNAL
Application LAPP servo cables according to Siemens * (see footnote) Standard FX8008 PLUS SIGNAL are a new generation of very highly flexible screened signal (encoder and resolver)- cables (P/Ns 00277101
Installation & Weatherproofing Guide for ENCOM Broadband Radios
Installation & Weatherproofing Guide for ENCOM Broadband Radios Read the following instructions before proceeding with your ENCOM Wireless Radio installation. Keep these instructions in safe location for
Standard Buccaneer - Ethernet
IP6 rated compliant PUR jacket on cable Shielded system shielded coupler Shroud on RJ45 Screw coupling Rewireable flex connector PCB mounted panel connector IDC termination panel connector Earth lead version
Outside Telephone Cable
Outside Telephone Cable Filled Core. Moisture Barrier. Description Soft copper wires insulated with high density polyethylene, foam skin or solid. Filled core, conformed by groups of pairs or by unit of
" EXCEEDING EXPECTATIONS WITH PERFORMANCE "
" EXCEEDING EXPECTATIONS WITH PERFORMANCE " Broadcast Cable Video Sales and Ordering Information: -800-245-4964 Technical Questions: E-Mail us at [email protected] Sales Department: E-Mail us at [email protected]
SMZ type 43 INTRODUCTION. The Radiall Type 43 coaxial connector range. Type 43 series - Features and benefits
INTRODUCTION The Radiall Type 43 coaxial connector range The Radiall range of Type 43 series connectors is fully approved (where applicable) to BT (British Telecom) standards as well as to British Standard
01. HARTING RJ INDUSTRIAL RJ45 ETHERNET CONNECTORS
. HARTING RJ INDUSTRIAL ETHERNET CONNECTORS Ethernet is is coming up to standard industrial interface. Therefore, automation devices such as controllers, sensors and actuators feature possess on one or
ATT-TP-76440 Ethernet Copper Cable & Ethernet Copper Assembly Specification
ATT-TP-76440 Ethernet Copper Cable & Ethernet Copper Assembly Specification Abstract Presented in this document are the standards to implement Electrical & Optical Ethernet components, cabling, connections,
Terminating 25-Pair Cable and 4-Pair Cross Connects
Terminating 25-Pair Cable and 4-Pair Cross Connects Estimated Time: 90 minutes Number of Teams: 2 Number of Team Members: one to four This Lab has four major parts that will be addressed separately. 1.
AMPSEAL* Automotive Plug Connector and Header Assembly
AMPSEAL* Automotive Plug Connector and Header Assembly Application Specification 24 SEP 97 Rev E All dimensions are given in millimeters unless otherwise specified. All dimensional tolerances are +0.2
ENGINEERING COMMITTEE
ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 02 2006 Specification for F Port, Female, Indoor NOTICE The Society of Cable Telecommunications Engineers (SCTE)
Unarmored Variable Frequency Drive (VFD) Cable Termination Guide
Authorized Distributor Unarmored Variable Frequency Drive (VFD) Cable Termination Guide Be Certain with Belden A Step-by-Step Look at the Connection/Termination of Unarmored VFD Cables Terminating Unarmored
Sound, Alarm & Security Cable 7
Electronics Sound, Alarm & Security Cable 7 Index Page The sound and security industry in the United States has grown from a simple and unsophisticated business, begun some 45 years ago, to one which has
Accelerating Light. Copper Cabling Solutions. Category 6A
Accelerating Light Copper Cabling Solutions Category 6A Category 6A Copper Cabling Solutions Fibernet designs and manufactures premium, high performance copper communication infrastructure and connectivity
Outdoor Use Waterproof I/O Connectors (Optical / Modular / Electrical) FO-BH, FO-BC, NT5, JN2 / W Series
COMPONENTS PRODUCT INFORMATION RoHS Compliant NEW Outdoor Use Waterproof I/O Connectors (Optical / Modular / Electrical) FO-BH, FO-BC, NT5, JN2 / W Series Optical FO-BH Series (Compact Type) CONNECTOR
Standard Buccaneer - USB
IP68 rated USB version 2.0 performance Plug and play capability Visual mating indication Shielded system Single and double ended cables Screw coupling PCB versions Dust and waterproof sealing when mated
INDOOR PHONE INSTALLATION (CONCEALED) TECHNICAL SPECIFICATION
TÜRK TELEKOMÜNİKASYON KASYON A.Ş. DIRECTORSHIP OF OPERATION AND MAINTENANCE Operation Directorate of Access Networks INDOOR PHONE INSTALLATION (CONCEALED) TECHNICAL SPECIFICATION ANKARA 2008 CONTENTS 1.
User s Manual. BNC Mini-High Res, 75 Ohm Termination Kit Connector Installation Guide (60-073-01)
User s Manual BNC Mini-High Res, 75 Ohm Termination Kit Connector Installation Guide (60-073-01) BNC Termination Kit Instructions This document is a compilation of Extron s instructions, together with
CIR. Index. Gexol. Standard CIR UL Listed Type TC-ER. Crush and Impact Resistant Without External Armoring. Arctic CIR UL Listed Type TC-ER-HL*
Gexol CIR Crush and Impact Resistant Without External Armoring Passes the same stringent crush and impact testing required by UL 2225 for Type MC-HL n Available in Standard and Arctic Grade Jackets n Highly
T-Extender E-Extender
T-Extender E-Extender TABLE OF CONTENTS SECTION - DESCRIPTION... SECTION - SPECIFICATIONS...3 SECTION 3 - INSTALLATION... SECTION - FRONT PANEL INDICATORS...7 SECTION - INTERFACE SIGNALS AND CABLES...8
Cable Guide. Cables, Connectors & Tools for installation of quality networks. TRIAX - your ultimate connection
Cable Guide Cables, Connectors & Tools for installation of quality networks TRIAX - your ultimate connection A Selection of the best Triax TX Cable range optimised for digital reception Simplification
6000 Series Buccaneer
Robust, instant connections for harsh environments 6000 Series Buccaneer - circular connectors that combine the ease of use of a push/pull coupling mechanism with proven environmental sealing. Available
6000 Series Buccaneer. 30 twist locking Tamperproof lock prevents accidental un-mating. Cat 5e shielded coupler Maintains shielding
circular connectors that combine the ease of use of a push/pull coupling mechanism with proven environmental sealing. Available with metal or plastic bodies, the range supports both data (USB and Ethernet),
Presenters Brett Weiss, Gabe Martinez, Brian Kroeger.
1 Presenters Brett Weiss, Gabe Martinez, Brian Kroeger. Topics to be covered: Cable identification Purpose of the various cable types Installation techniques Building Infrastructure Overview of networking
Security & Control Cables
Security & Control Cables Our multi-conductor cables are manufactured in a wide variety of gage sizes, shielding configurations and jacketing materials including plenum, riser and general purpose. Applications
ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 123 2011
ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 123 2011 Specification for F Connector, Male, Feed-Through NOTICE The Society of Cable Telecommunications Engineers
PCb Cable mount twinax. ConneCtorS
PCb Cable mount twinax ConneCtorS technical CharaCteriStiCS SPeCiFiCationS temperature rating: -55 C to + 125 C Corrosion: MIL-STD-202 Method 101, Test Condition B Shock: MIL-STD-202 Method 213, Test Condition
COAXICON Contacts. RF Coax Connectors. Product Facts
COXICON Contacts Product Facts Tyco Electronics provides a variety of contacts for coaxial connectors Contacts are available in a range of sizes that may be used with the various types of coaxial cable
MICROCABLES. A complete vision of your connectivity needs. Catalogue
MICROCABLES A complete vision of your connectivity needs Catalogue ELECTRONIC Filotex Introduction Application Nexans s line of microcables is designed towards the increasing requirements of electronics
Digital Systems Ribbon Cables I CMPE 650. Ribbon Cables A ribbon cable is any cable having multiple conductors bound together in a flat, wide strip.
Ribbon Cables A ribbon cable is any cable having multiple conductors bound together in a flat, wide strip. Each dielectric configuration has different high-frequency characteristics. All configurations
MYTHBUSTING Takes on Shielded Cabling
MYTHBUSTING Takes on Shielded Cabling Herb Congdon Brian Davis Objectives Take on myths of shielded cabling and use modern-day science to show what's real and what's fiction - through trial and error actually
Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System
Revised Sept--22-2009 Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System Description The sealed circular RJ45 connector system is designed for use in harsh environments. The connector
LocoNet, the Digitrax Difference
LocoNet, the Digitrax Difference LocoNet is Digitrax's method of communication between LocoNet compatible devices on a model railroad layout. LocoNet Compatible devices are designed to work together on
BIX Cross-Connect System Distribution Connectors, Multiplying Connectors and Modular Jack Connectors
C O M M E R C I A L N E T W O R K I N G C O P P E R 15.13 Distribution Connectors, Multiplying Connectors and Modular Jack Connectors A0393146 QCBIX1A4 Connector BIX Distribution Connector The BIX Distribution
Generator DoCKInG StatIonS
Generator DOCKING STATIONS TRYSTAR Portable Power Cable Cam to cam cable extensions 2000V, 100A-400A rated to NEC table 400.5 (B) All portable power cable sold is highly flexible and UL & C-UL or CSA Listed
Ethernet Cat 5e & Cat 6 Patch Panels
Ethernet Cat e & Cat Patch Panels Copper :: RJ/IDC Models EPPE-CTE & EPPE-CAT User Manual Applys to : EPPE-CTE :: EPPE-CAT Telect, Inc., All Rights Reserved, 9- A0.09.9.000 :: telect.com Ethernet Cat e
Outside Plant DS3 Deployment Connectivity Hardware TROMPETER
Outside Plant DS3 Deployment Connectivity Hardware TROMPETER E L E C T R O N I C S, I N C. 3G -WIRELESS PASS THRU JACK MODULE WITH NON-INTRUSIVE SIGNAL MONITORING PORTS One of the problems involved with
Analog Multi-Pair Snake Cable High-Flex and NEC Rated Cables
B R I L L I A N C E B R O A D C A S T C A B L E S 19.16 High-Flex and Rated Cables Especially designed for the broadcast industry, Belden s full faily ulti-pair audio Snake cables feature options and construction
Microphone and Musical Instrument Cable Overview
B R I L L I A N C E B R O A D C A S T C A B L E S 19.3 Microphone and Musical Instruent Cable Overview Flexible Microphone Cables Belden icrophone cable is used for connecting low level icrophones or usical
Times Microwave Systems Hermetically Sealed Assemblies
SCOPE This Specification details the Electrical, Mechanical and Environmental Characteristics of Times Microwave Systems MILTECH 340.34 Diameter Hermetically Sealed Coaxial Transmission Lines. This product
Gulf Cable & Electrical Ind. Co.
CONTENTS INTRODUCTION PRODUCT RANGE I PRODUCT DATA TABLES Irrigation 1 Coaxial s for T.V/ Satellite Antenna etc 2 Data Transmission s - 4 pair 24 AWG 3 TELEPHONE CABLES Telephone cables CCP-LAP & CCP-LAP-SS
Shielding Effectiveness Test Method. Harbour s LL, SB, and SS Coaxial Cables. Designs for Improved Shielding Effectiveness
Shielding Effectiveness Test Method Harbour s LL, SB, and SS Coaxial Cables Designs for Improved Shielding Effectiveness Harbour Industries 4744 Shelburne Road Shelburne Vermont 05482 USA 802-985-3311
Network Cabling Guide
Network Cabling Guide Poor or incorrectly installed network cabling can cause numerous problems with your computer network. Whilst we recommend that you employ a network / cabling specialist to wire and
RF & Microwave cable assemblies C291
ERTIFIED C AS 9100 RF & Microwave cable assemblies C291 B CONTENTS Pages Introduction... B-4 Specify the right cable for your application... B-5 Finder guide cables vs insertion loss... B-6 to B-7 Flexible
Outdoor Carrier Class Shielded Ethernet Cable. Datasheet. Models: PRO, CARRIER, Connectors. Increase Performance. Extreme Weatherproof
Datasheet Outdoor Carrier Class Shielded Ethernet Cable Models: PRO, CARRIER, Connectors Increase Performance Extreme Weatherproof ESD Damage Protection Extended Cable Support 1 2Datasheet Protect your
Why FOUNDATION Fieldbus?
Product Bulletin PB 244-R3 Fieldbus Cables Fieldbus Tye A cables rovide installation flexibility in many different environments, including outdoors and where multile or extended cable runs are required.
Schneider Automation Modbus Plus Network Installing Clustered Node Devices 31000939 00 Version 2.0
Schneider Automation Modbus Plus Network Installing Clustered Node Devices 3000939 00 Version.0 Modbus Plus devices must be installed as specified in a network layout plan, showing each device s mounting
LOW LOSS CABLE PAG. 1
LOW LOSS CABLE PAG. 1 INTRODUCTION Following many requests we received regarding the need for low-loss custom cable assemblies, we have set up a special production of high performance coaxial cable assemblies
KNOW YOUR OPTIONS: 230 KV POWER CABLES
KNOW YOUR OPTIONS: 230 KV POWER CABLES 71 CONDUCTOR MATERIAL AND SIZE Conductor material is a matter of both customer preference and required current carrying capacity At 230 kv, copper is most common
EH-20 20m antenna. By VE3RGW
EH-20 20m antenna By VE3RGW Equivalent circuit of EH-20 (prototype 2A) antenna system. Upper cylinder Lower cylinder Ground Counter pose Phasing coil Impedance transformer and tune circuit Tune coil Feed
CIN::APSE MICROMINIATURE D-SUB
INTRODUCTION CINCH has been producing filter connectors for years and has acquired an in depth knowledge of EMC protection. CINCH offers fast delivery on a wide range of standard filtered connectors and
EMC Test Chamber Solutions RF Cable Assemblies and Connectors
EMC Test Chamber Solutions RF Cable Assemblies and Connectors RF CABLE ASSEMBLY AND CONNECTOR SOLUTONS FOR EMC MMUNTY AND EMSSON COMPLANCE TESTNG E X T N T R A T E D E P T H --> POWER LEVEL: -40.00 dbm
Cables and Accessories Selection Guide
Cables and Accessories Selection Guide From data centers to robotics to patient monitoring equipment, we re committed to enabling the next generation of faster, smaller and smarter design. 3M offers an
Testing, Repairing & Installing Home Telephone Wiring Disclaimer
Testing, Repairing & Installing Home Telephone Wiring Disclaimer This information is intended to assist customers of telephone service to understand the telephone wiring in their home. This information,
Cat7/Class F New Installation Concept New infrastructure. Handbook
Cat7/Class F New Installation Concept New infrastructure Handbook contents 1 Introduction 3 2 What is the Cat7/Class F installation concept 3 3 Distribution centre 3 3.1 Patch Modules 3 4 How to handle
Cable Specifications. T3 Trunk Cabling APPENDIX
APPENDIX B This appendix contains details on the MGX 8230 cabling. It includes the following sections: T3 Trunk Cabling Frame Relay Cabling DC Power Cabling AC Power Cabling Control and Clock Cabling External
Patch Cords / Cable / Cable Assemblies. Patch. Cords/Cable/ Premise Connectivity Systems. Cable Assemblies
Patch Cords / Cable / Cable Assemblies Premise Connectivity Systems Patch Cords/Cable/ Cable Assemblies w w w. s i g n a m a x. c o m Category 6A 10G Patch Cords C1 Patch Panels and Cross- Category 6 Patch
LS Data Communication Product
www.lscable.com 2007 LS Cable, Ltd. All right reserved. This product or document is protected by copyright and distributed under licenses restricting its use, copying, distribution, and decompilation.
Section 5 161 kv Power Cables
Know Your Options: 161 kv Power Cable 61 material and size material is a matter of both customer preference and required current carrying capacity Copper conductor common for larger loads When both copper
Wiring with this step-by-step guide, you can make telephone, Internet, video, and audio connections anywhere in the house
Multimedia Wiring with this step-by-step guide, you can make telephone, Internet, video, and audio connections anywhere in the house BY BRIaN walo voice & DATA video AuDIO Because I m an electrician, the
75 Ω Transmission System
NRAO NTC-DSL Laboratory Report Dynamic Spectroscopy Laboratory Report Series Report 03 September, 2006 75 Ω Transmission System Chaitali R. Parashare Department of Electrical and Computer Engineering,
Sunridge MCB Series Miniature Coaxial Interconnect, 2.5mm or 2.0mm Mated Height
Sunridge MCB series coaxial product fulfills the rigorous requirements of high frequency data transmission in digital world. Constructed in supreme Teflon coax cable and advanced mechanical design, MCB
Universal MATE-N-LOK Connectors
Product Facts Pins and sockets can be intermixed in the same housing Positive polarization Rear cavity identification completely enclosed in housings Positive locking housings Insulation capability to.00
Networking 101 (Networking Basics) Presentation to UCHUG - 1/03/07 G. Skalka
Networking 101 (Networking Basics) Presentation to UCHUG - 1/03/07 G. Skalka What is a network? A computer network is two or more computers connected together using a telecommunication system for the purpose
UTP Video Cables. Pair 2 - Category 5E Type 100Ω. The first pair is used for video transmission.
UTP Video Cables West Penn Wire introduces its new line of UTP security cables,v/cat. The V/CAT ( Video over Category 5E) is designed for the video over UTP applications. The cables are constructed with
Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH
Amphenol C 091 A/B/D Circular Connectors Amphenol-Tuchel Electronics GmbH C 091 A Main Features Metal threaded coupling acc. to IEC. Number of contacts are 2 to 8, 12 and 14. Internal metal strain relief
FN2001-A1 Network module (SAFEDLINK) Mounting Installation
FN00-A Network module (SAFEDLINK) Mounting Installation A6V050_f_en_-- 05-0-6 Building Technologies Division Legal notice Legal notice Technical specifications and availability subject to change without
XG2. Flat Cable Connectors for PCBs. Achieve Total Cost Reduction through High-density Mounting and Reduced Wiring. Terminal Arrangement
Flat Cable Connectors for PCBs XG2 Achieve Total Cost Reduction through High-density Mounting and Reduced Wiring IDC connections allow you to wire all terminals at once without terminating the cable. Can
Gexol. Gexol. The Global Cable Solutions Company. Designed for safe, reliable performance in the harshest oil and gas operating environments
Gexol Gexol World Class World Class Designed for safe, reliable performance in the harshest oil and gas operating environments Power Control Instrument VFD The Global Cable Solutions Company Gexol World
PROFIBUS cable. PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications
Data Sheet 10/63-6.47-EN Rev. D PROFIBUS cable PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications PROFIBUS PA cables Non-Ex (Hazardous) applications Ex (Hazardous) applications
E Series. E Series. Category 6 and 5e. Features
E Series Category 6 and 5e CommScope, world leader in copper and fiber connectivity, offers the E Series product line as the ideal solution to all your infrastructure needs for safe and reliable data transmission.
KNOW YOUR OPTIONS: 69 KV XLPE POWER CABLE
Know Your Options: 69 kv XLPE Power Cable 3 material and size material is a matter of both customer preference and required current carrying capacity Copper conductor common for larger loads When both
CAVEL VS80205 MADE IN ITALY 1000 V
0,05 9,00 x 7,20 (Pet) (LSZH) Attached CE01 CE02 Sheath Colour black black red Non-migrating Polyester tape longitudinally overlapped (Pet) 25 x 23 µm Outer sheath of Thermoplastic material - black - halogen-free,
CAT 5 Cable / RJ 45 Connectors and Making Cables for different connections
CAT 5 Cable / RJ 45 Connectors and Making Cables for different connections RJ 45: (RJ xx: telephone connection interfaces, registered with the FCC, the U.S. Federal Communications Commission.) Pins: When
Ethernet Patch Cord Wiring
Ethernet Patch Cord Wiring C ONTENTS Ethernet Patch Cords & RJ-45 Connectors... 2 Ethernet Patch Cords and UTP Cabling... 3 What s all the twisting about?... 4 Ethernet Applications... 5 568A & 568B Wiring
INNOVATION SUPPORTED BY A TRULY SOLID INDUSTRIAL ORGANIZATION.
CONNECTORS 2014 INNOVATION SUPPORTED BY A TRULY SOLID INDUSTRIAL ORGANIZATION. Stelvio Kontek S.p.A. is one of the leading groups in the connectors market. With a solid background in the sector and having