Installation Instructions Model SCM-8S / LCM-8S / FCM-6S Model CSB



Similar documents
D287/D288/D292/D293A/D293E

FN2001-A1 Network module (SAFEDLINK) Mounting Installation

Schneider Automation Modbus Plus Network Installing Clustered Node Devices Version 2.0

Lighting Controls ! WARNING RISK OF ELECTRIC SHOCK. Installation Instructions DESCRIPTION

Advantium 2 Plus Alarm

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

Product and functional description

Data sheet GIOD.1 Input/output module with CAN bus. ERP no.: Data sheet GIOD.1 V_3.0

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

LCD5500Z / PKP-LCD v3.x Installation Instructions

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit

DBS720 / FDS221-R / FDS221-W Sounder base, Alarm sounders

Reliance DuraStar ORDINARY LOCATION INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS

AC-115 Compact Networked Single Door Controller. Installation and User Manual

Digital input modules

Input module, input/output module

AIS750 Series Alarm Annunciator

SSW-iLM Keypad. Wire Harness Configuration. Note: This product is designed to be installed and serviced by security and lock industry professionals

HMI display Installation Guide

SECTION LOW VOLTAGE LIGHTING CONTROLS

FIREDEX Conventional Fire Panels

Installation Instructions. Thermo Call TC3

TR21, TR22, TR23, and TR24 Wall Modules

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

Accessories. Remote Annunciator Module RAM7 RAM7: Remote Annunciator Module. Quick reference. v. 1.0_in

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases

Intruder alarm. Pro 21 TM /Solfà TM. Installation and operating instructions N0064EG2/00

ACTIVE 5 ENGINEERING MANUAL

Liebert Universal Monitor

Installation Instructions

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

PDS-750-TR Touring Power Supply Operator s Manual

Modular I/O System Analog and Digital Interface Modules

Residential Gateway (RG) Battery Backup

WIRELESS STATUS MONITOR

Disabled Toilet Alarm. Contractor Pack. Installation & Operating Instructions

SP4-LOC SAFEPATH4 REMOTE MICROPHONE AND LOCAL OPERATOR CONSOLE

INSTALLATION INSTRUCTIONS

WxGoos-1 Climate Monitor Installation Instructions Page 1. Connections. Setting an IP Address

Installation Instructions. ThermoCall TC4. Entry/Advanced

ALARMS-xx. Remote Alarm Unit Setup Guide RESET ALL

PDS-375-TR Touring CB Power/Data Supply Operator s Manual Rev 1.2

ScreenLogic Wireless Connection Kit. Installation Guide. pool/spa control system

RM410. Hardware Installation Guide. Quick Start Guide. Rack Mounting Kit. Version 1.00 Edition 1, 12/2012

CB200W Water Leak Detection Panel Application Guide

CutMaster Major External Replacement Parts

I STAR COMPUTER CO., LTD

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

SmartWire Panel Wiring Solutions the easy way to connect

HP UPS R1500 Generation 3

FIRE ALARM PANEL & SYSTEM OPERATION ID50 SYSTEM. The Fire Alarm System can be activated in the following ways :~

TX OPEN RS232/485 module

INPUT/OUTPUT MODULE CONVERT INPUTS AND OUTPUTS TO WIRELESS

WIND ALARM. Wind Speed Alarm. Wind Speed. Set Point 2. Set Point 1 NEW BEDFORD, MA USA

Repeaters and Mimics Data Sheet

CO2 Alarm. Operation. Application

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

LOXONE 12 Channel Amplifier

T7560A,B,C Digital Wall Module

Install the DeviceNet Module using the following procedure:

How to Set Up Your NSM4000 Appliance

USER MANUAL. 914 Power Amplifier MODEL: P/N: Rev 1

HM-W536 Install Guide

SCREENLOGIC INTERFACE WIRELESS CONNECTION KIT

Operation and Installation Manual

Acano solution. Acano Solution Installation Guide. Acano. January B

STAND-ALONE PROXIMITY ACCESS CONTROL SYSTEM

Single Station Remote Alarm

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

WD-AMX Water Detection Controllers

ECR Shelf System Installation Guide Centralized Rack Mount Call Recording

Fire Control Panels. Remote Annunciator Panels. UL, ULC, CSFM Listed; FM Approved; MEA (NYC) Acceptance* Features. Introduction

Owner s Manual Ignition Upgrade Module for 2004-up Carbureted Harley Davidson Motorcycles P/N ASM5075

SENTRON Switching and Protection Devices Air Circuit Breakers

ENGLISH

Part Name/Description Part Number Quantity. Power Cable

The RIDZ 8x2 Audio Switcher

Product and Application Description

CutMaster Major External Replacement Parts

I NTERFACE CABLE ADAPTER MODULE

Kit Watt Audio Amplifier

Telebyte 209 Short Haul Modem

WIRELESS REMOTE ASSEMBLY, 24VDC, 1 TRANS,1 REC

SIMATIC S Getting Started for First Time Users. Order No.: 6ZB5310-0NC02-0BA0 04/2007 A5E

Electro-Pneumatic Bus Door Control Mechanism

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

Alarm over IP. IRIS Touch Home Installation Manual. Version 1.0 ENGLISH. Now certified and compliant with EN50131, EN50136 Security Grade 4 ATS6

AUTODIALLER / QUICKDIALLER - SA132

Switches and Indicators. Swisstac

Wireless Base Station Single and Multiple Headsets

Version Date Author Description Jpo First version Jpo FET output descriptions made clearer

Conventional Fire Detection and Extinguishant Control System Specification

D Gas supply secure at a glance DRÄGER ALARM MANAGEMENT SYSTEM

GERONIMO ANALOGUE HEAVY DUTY TELEPHONE

JBL CINEMA SB350. Home Cinema 2.1 soundbar with wireless subwoofer

How To Use A Power Supply On A Powerline 2.2 (Ai)

PK5500 v1.1 Installation Instructions

PCS0100en Persy Control Services B.V. Netherlands

PROXIMITY CARD READERS C-10, C-20, C60, C70

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

Transcription:

s Installation Instructions Model / / FCM-6S Model CSB Switch Control Module (500-035800 / S24235-B103-A2) LED Control Module (500-035810 / S24235-B102-A2) FAN Control Module FCM-6S (500-035820 / S24235-B104-A2) CAN Sounder Board (500-033130 / S24235-A105-A2) INTRODUCTION The SIEMENS Models, and FCM-6S, are similar in appearance and identical in installation. The SIEMENS Model Switch Control Module (Figure 1) contains eight switches and eight pairs of LEDs. Each pair contains one bi-color (red/green) and one yellow LED. The functions of the switches and LEDs are programmed using the Zeus Tool. All LEDs can be programmed ON, OFF, or FLASHING. The is used for manual control of the system. The SIEMENS Model LED Control Module (Figure 2) contains eight pairs of LEDs. Each pair contains one bi-color (red/green) and one yellow LED. The functions of the LEDs are programmed using the Zeus Tool. All LEDs can be programmed ON, OFF, or FLASHING. These LEDs are used for system status annunciation. The SIEMENS Model FCM-6S Fan Control Module (Figure 3) contains six sets of three pushbutton switches and their corresponding LEDs. The ON and AUTO switches both have one bi-color (red/green) LED while the OFF switch has one bicolor and one yellow LED. The functions of the switches and LEDs are programmed using the Zeus Tool. All LEDs can be programmed ON, OFF, or FLASHING. The FCM is designed for general control requiring ON/OFF/AUTO operation. Figure 1 Switch Control Module Figure 2 LED Control Module Figure 3 FCM-6S LED Control Module s

The SIEMENS Model CSB CAN Sounder Board (P/N 500-033130 / S24235-A105-A2) is an optional module that can be ordered separately. It contains a sounder (buzzer) that Figure 4 can be used with the or FCM-6S to CSB CAN Sounder Board provide audible feedback to indicate that a switch closed properly and communication was successful. The CSB requires no programming. All modules mount on the inner door of an enclosure. OPERATION SCM Controls and Indicators The contains eight switches and eight pairs of LEDs. Each switch is associated with a pair of LEDs. Pressing of any of the eight switches generates a unique CAN message on the bus that indicates which switch was pressed. A CAN message to the produces a preprogrammed output to the corresponding LED (ON, FLASHING or OFF). An open collector is provided for connection to the CAN Sounder Board (CSB), a separate audio module. The CSB provides an audible feedback to indicate that the switch closed properly. LCM Controls and Indicators The contains eight pairs of LEDs. A CAN message from to the LCM- 8S produces a preprogrammed output to any of the corresponding LEDs (ON, FLASHING, or OFF). FCM Controls and Indicators The FCM-6S contains six sets of three pushbutton switches and their corresponding LEDs. Pressing any of the six ON, OFF or AUTO switches generates a unique CAN message on the bus that indicates which switch was pressed. A CAN message to the FCM-6S produces a preprogrammed output to the corresponding LED (ON, FLASHING or OFF). An open collector is provided for connection to the CAN Sounder Board (CSB), a separate audio module. The CSB provides an audible feedback to indicate that the switch closed properly. CSB Controls and Indicators The CSB contains a sounder (buzzer) that sounds when any switch on an FCM-6S or is pressed. Only one CSB is required for audible feedback; more can be connected to increase the volume if needed. PRE-INSTALLATION Set the board address for each / / FCM-6S using both of the ten-position rotary switches located on the back of the board (See Figure 5). Each of these addresses must be a sub-address of the DAC-NET and must be the same as the addresses assigned in the Zeus Programming Tool. The CSB does not require address setting. After setting the address, label each switch or LED. When viewed from the front panel of the / / FCM-6S, the labels are on the left and the control switches and LEDs are on the right. Refer to the Zeus configuration for the address of each module and its assigned functions. Remove the label strip from its slot and type or print a brief function identifier for each switch. After completing the label strip, insert in back into its slot (See Figure 6). 2

ROTARY ADDRESS SWITCHES PLUG-IN CABLE CONNECTION Figure 5 / / FCM-6S Address Switches And Cable Connections Figure 6 Inserting A Label into The Back Of The FCM-6S INSTALLATION CAN Sounder Board The CSB is normally positioned at the last, or FCM-6S. If desired, multiple CSBs can be installed. The CSB mounts on the stud of the / / FCM-6S module that it connects to. 1. Determine the position of the CSB. (This is normally at the last SCM- 8S, or FCM-6S module.) 2. If necessary, remove nut from stud of / / FCM-6S where CSB is to be mounted. 2. Place mounting hole on the CSB over stud. 3. Secure with nut supplied with / / FCM-6S. 3

WIRING (Refer to Figure 7.) Remove ELECTRICAL POWER prior to working on equipment. Each / / FCM-6S module is a node in the CAN bus. Each / / FCM-6S connects through the CC-5/CC-2 CAN bus via a plug-in cable to the DAC-NET or to another / / FCM-6S module. Up to 99 / / FCM-6S modules, in any combination, can be connected to the CAN bus of each DAC-NET. Each / / FCM-6S module is shipped with one CCS cable. INSTALL CAN TERMINAT P/N 110-134215 (SHIPPED WITH NIC-C) or CAN TERMINAT C24235-A1-K2 (SHIPPED WITH DAC-NET) TO CC-5/CC-2, P3 CABLE MODEL # CCL FCM-6S FCM-6S Buzzer CSB CABLE MODEL # CCS Figure 7 Typical Wiring For / / FCM-6S And CSB 4

Cable connections for / / FCM-6S / CSB modules are shown in the following table and in Figure 7: / / FCM-6S / CSB CABLE CONNECTIONS Cable Description Part Number Connection CCL CAN-CABLE- Long 30 in. (100cm), 6- conductor 599-634214 C24235-A1-K6 Connects from row to row (on door) for / / FCM-6S / CSB / modules. Also connects from P3 on CC- 5/CC-2 to first / LCM- 8S / FCM-6S CCS CAN-CABLE- Short 5½ in. (14cm), 6- conductor 555-133539 C24235-A1-K4 Connects / / FCM-6S / CSB modules to / / FCM-6S / CSB modules in a single row Figure 8 Connecting Power For / / FCM-6S Modules 5

ELECTRICAL RATINGS 24V Back Plane Current 0 24V Screw Terminal Current 14mA max + 1mA per active LED 6.2V Back Plane Current 0 24V Standby Current 14mA max + 1mA per active LED For CE applications in Cerberus E100 systems refer to Installation Instruction A24205-A334-B844 (English) or A24205-A334-A844 (German) Siemens AG, I BT DE FS SYS, 2003 Siemens Building Technologies, Inc. Florham Park, New Jersey 07932 Siemens Building Technologies, Ltd. Brampton, Ontario L6T 5E4 CN Issued by Siemens AG I BT DE FS SYS D-81379 Munich Delivery subject to availability; right of technical modifications reserved. Order No. A24205-A334-B812 (Edition 2) Printed in the Federal Republic of Germany on environmental chlorine-free paper.