Telebyte 209 Short Haul Modem
|
|
|
- Kelly Eaton
- 9 years ago
- Views:
Transcription
1 Telebyte 209 This document provides installation instructions for the Telebyte 209 (Keri Systems P/N SHM-232). This short haul modem can be used to assist in long-distance, direct, connections between a host computer and an access control network. The Telebyte 209 is fully compatible with PC/AT serial communication ports and requires no external power for its operation. 1.0 Specifications 1.1 Dimensions 0.85 inches High x 1.30 inches Wide x 3.00 inches Long (2.16 cm H x 3.30 cm W x 7.62 cm L) 1.2 Connector DB-9F with screw connection terminals 1.3 Cable Run Distance Per Wire Gauge Using Belden 9502 or its equivalent, see Table 1 Data Rate (KBPS) Wire Gauge Baud 4.9 Miles 3.1 Miles 1.8 Miles 2.0 Installation The short haul modems are shipped in pairs. One modem is attached to the master controller on the access control network. The other is attached to the host computer's COM port. NOTE: Each short haul modem has a small switch allowing the modem to be set for use with either Data Terminal Equipment (DTE) or Data Communication Equipment (DCE) devices. Please ensure that each modem's switch is set correctly. The switch is used to set the modem to match the type of device it is connected to. Insert a thin-blade screwdriver into the switch slot and verify the switch is turned completely counter-clockwise for a DTE application or completely clockwise for a DCE application. Applying too much pressure while turning the switch may damage the modem. NOTE: When a KDP-252 cable is used, make sure the short haul modem switch is set for a DCE application. Web: [email protected] Page 1 of 5
2 Telebyte Connecting to a PXL-250 Controller The DB-9 connector on the short haul modem and on the PXL-250 controller are both female. To make the short haul modem to controller connection a DB-9 male-to-male connector is provided (see Figure 1). Set the switch on the short haul modem to the DCE position by gently turning the switch completely counter-clockwise. Figure 1: PXL-250 Controller to Connection 2.2 Connecting to an EntraGuard Gold Controller A short haul modem may be used with an EntraGuard Gold master controller however, due to the size of the short haul modem, an extension cable must be made to allow the modem to be located outside of the controller box so the box may close properly. The DB-9 connector on the short haul modem and on the EntraGuard Gold controller are both female. To make the short haul modem to controller connection two DB-9 male connectors are required and a minimum of 3 conductor cable (length as needed). Set the switch on the short haul modem to the DCE position by gently turning the switch completely counter-clockwise. Figure 2: EntraGuard Gold Controller to Connection Web: [email protected] Page 2 of 5
3 Telebyte Connecting to the Host Computer - DB-9 to DB-9 If the host computer's COM port uses a male DB-9 connector the short haul modem can be plugged directly to the COM port (see Figure 2). Set the switch on the short haul modem to the DCE position by gently turning the switch completely counter-clockwise. Figure 3: Host Computer to Connection 2.4 Connecting to the Host Computer - DB-9 to DB-25 If the host computer's COM port uses a DB-25 connector a DB-25 to DB-9 reduction plug must be used Using a "Straight-Through" Reduction Plug If the reduction plug uses straight-through wiring (pins 2 and 3 on the 25 pin side go straight through to pins 2 and 3 on the 9 pin side) make the connection as shown in Figure 3. Set the switch on the modem to the DTE position by gently turning the switch completely clockwise. Figure 4: Host Computer to Connection Straight Through Reduction Plug Web: [email protected] Page 3 of 5
4 Telebyte Using a "Twist" Reduction Plug If the reduction plug uses 2-3 twist wiring (pin 2 on the 25 pin side goes to pin 3 on the 9 pin side and pin 3 on the 25 pin side goes to pin 2 on the 9 pin side) make the connection as shown in Figure 4. Set the switch on the short haul modem to the DCE position by gently turning the switch completely counter-clockwise. Figure 5: Host Computer to Connection 2 3 Twisted Reduction Plug Web: [email protected] Page 4 of 5
5 Telebyte to Wiring Two sets of twisted pair cables are used to connect the short haul modems. Connect the cable between the two modems as shown in Figure 5. The shield wire is not connected at either end of the cable. Figure 6: to Wiring Diagram End of document. Web: Page 5 of 5
NOTE: It is the responsibility of the installation organization to have only technically qualified personnel performing the installation.
This quick start guide provides, basic installation information, drawings, first time power-on instructions, and short descriptions of key terms and concepts for installing the EntraGuard Platinum Telephone
PXL-500 / PXL-510 Tiger Controller Quick Start Guide
This quick start guide provides, basic installation information, drawings, first time power-on instructions, and short descriptions of key terms and concepts for installing controllers. These instructions
Cable Specifications and Information
APPENDIX A This appendix provides the connector and pinout information you need for making or purchasing cables used with Cisco VG224 voice gateway. To order cables from Cisco, see the Obtaining Technical
Cable Specifications and Information
APPENDIXA This appendix provides the connector and pinout information you need for making or purchasing cables used with Cisco VG350 Voice Gateway. To order cables from Cisco, see the Obtaining Technical
Cabling Specifications
APPENDIX A This appendix provides cabling and pinout information for feature cards on the Cisco AS5350XM and Cisco AS5400XM universal gateways. It contains the following sections: 2-Port and 4-Port T1
PXL-250: Network Wiring
This document provides the network wiring requirements for a PXL-250 access control network. Network Requirements The PXL-250 uses a half-duplex, RS-485 communication bus. Per the RS-485 specification,
Serial Cables & Adapters
WTI Part No. 9 Rev. B Serial Cables & Adapters for WTI Products . Introduction This publication describes the serial cables and snap adapters that are used to connect your RSM-R series or MPC series unit
Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000
Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000 1.0 Introduction A Technical Application Note from Doppler System July 5, 1999 Version 3.x of the DDF6000, running version
RS-232 COMMUNICATIONS
Technical Note D64 0815 RS-232 COMMUNICATIONS RS-232 is an Electronics Industries Association (EIA) standard designed to aid in connecting equipment together for serial communications. The standard specifies
RJ11 RS-232 Interface
H NS TN30 RJ11 RS-232 Interface 1.0 General The back panel of the CPP-3794 provides a combination of 9 pin DB connectors and RJ11 connectors for connecting RS-232 serial cables. The 9 pin DB connector
No Phone Line System. Quick Start Guide NPL II. 1.0 Installation
Used in conjunction with EntraGuard Gold Telephone Entry Systems, the provides No Phone Line communication and door or gate control through existing building telephone lines without the need purchase phone
Cabling Guide for Console and AUX Ports
Cabling Guide for Console and AUX Ports Contents Introduction Prerequisites Requirements Components Used Conventions Table of Routers with Console and AUX Ports Console Port Settings for Terminal Connection
FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology
FOSTCDR pn 8684R1 FOSTCDR-0812ds page 1/5 Industrial Serial to Multimode Fiber Optic Converter Data Rates up to 115.2 kbps 2.5 Mile (4 km) Range 10 to 30 VDC Input Voltage Wide Operating Temperature 2000V
QSE-CI-NWK-E Control Interface
QSE-CI-NWK-E Control Interface 369373e 1 04.05.16 The QSE-CI-NWK-E is a versatile integration access point for Lutron QS-based systems. Through either RS232 or TCP / IP over Ethernet, third-party devices
Configuring the Siemens TC35 modems for use with the MI2292
Configuring the Siemens TC35 modems for use with the MI2292 The following instruction describe how to set up GSM communication between an MI2292 Power Quality Analyser Plus and a computer 1. Equipment
Troubleshooting and Diagnostics
Troubleshooting and Diagnostics The troubleshooting and diagnostics guide provides instructions to assist in tracking down the source of many basic controller installation problems. If there is a problem
No Phone Line II-48 System
Used in conjunction with an EntraGuard Telephone Entry System, the -48 provides No Phone Line communication and door or gate control through existing building telephone lines without the need to purchase
Data Bulletin. Communications Wiring for POWERLINK G3 Systems Class 1210 ABOUT THIS BULLETIN APPLICATION INTRODUCTION.
Data Bulletin 1210DB0002R3/05 03/2005 LaVergne, TN, USA Communications Wiring for POWERLINK G3 Systems Class 1210 Retain for future use. ABOUT THIS BULLETIN This data bulletin describes the proper wiring
Cable Pinouts. SRP I/O Module
Cable Pinouts C This appendix lists the cables and connector pinout assignments for the cables used with the ERX-700 series and ERX-1400 series. Topic Page SRP I/O Module C-1 CT1 and CE1 I/O Modules C-4
2 To 1 Serial (RS-232) AUTO SWITCH. AS-251S User Manual
2 To 1 Serial (RS-232) AUTO SWITCH AS-251S User Manual Read this manual thoroughly and follow the installation procedures carefully to prevent any damage to the AS-251S and/or the devices it connects to.
Console Cables for GarrettCom Managed Products
Console Cables for GarrettCom Managed Products The table below guides users through the Console cables for GarrettCom Inc. products Product Family Magnum DX Series Magnum 6K 19 rack switches, plus 6K16,
2S RS232 Multi Serial PCI Card Installation Guide
2S RS232 Multi Serial PCI Card Installation Guide 1. Introduction Congratulations on purchasing this high performance PCI multi serial card. The card is high speed PCI bus based and plug-and-play compliant.
1-Port R422/485 Serial PCIe Card
1-Port R422/485 Serial PCIe Card Installation Guide 1. Introduction Thank you for purchasing this 1-Port RS422/485 Serial PCI Express (PCIe) Card. It is a universal add in card that connects to a PC or
Cable Specifications. T3 Trunk Cabling APPENDIX
APPENDIX B This appendix contains details on the MGX 8230 cabling. It includes the following sections: T3 Trunk Cabling Frame Relay Cabling DC Power Cabling AC Power Cabling Control and Clock Cabling External
USER MANUAL. MODEL 460 Series G.703 Coax to Twisted Pair Adapter (Balun)
USER MANUAL MODEL 460 Series G.703 Coax to Twisted Pair Adapter (Balun) An ISO-9001 Certified Company Part #07M460-E Doc. #019021UE Revised 02/23/00 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301)
Cable Guide Including all PortServer TS, Digi Connect, and Digi One Products
Cable Guide Including all PortServer TS, Digi Connect, and Digi One Products 90000253_E Digi International Inc. 2005. Digi, Digi International, the Digi logo, the Making Device Networking Easy logo, Digi
Introduction: Implementation of the MVI56-MCM module for modbus communications:
Introduction: Implementation of the MVI56-MCM module for modbus communications: Initial configuration of the module should be done using the sample ladder file for the mvi56mcm module. This can be obtained
Troubleshooting and Diagnostics
Troubleshooting and Diagnostics The troubleshooting and diagnostics guide provides instructions to assist in tracking down the source of many basic controller installation problems. If there is a problem
Cable Guide For all PortServer TS, Digi Connect, and Digi One Products
Cable Guide For all PortServer TS, Digi Connect, and Digi One Products 90000253_F Digi International Inc. 2011. Digi, Digi International, the Digi logo, Digi One, Digi Connect, PortServer TS, and RealPort
Cable Guide For all PortServer TS, Digi Connect, and Digi One Products
Cable Guide For all PortServer TS, Digi Connect, and Digi One Products 90000253_G Digi International Inc. 2013. Digi, Digi International, the Digi logo, Digi One, Digi Connect, PortServer TS, and RealPort
omega.com ΩOMEGA RS232 Multi-Drop www.omega.com FMA1600-MDB Multi-Drop Box
omega.com ΩOMEGA RS232 Multi-Drop www.omega.com FMA1600-MDB Multi-Drop Box 1 3/29/2010 Rev.0 DOC-OMEGABB9MAN 2 Introduction FMA1600-MDB Multi-Drop Box Operating Bulletin The FMA1600-MDB Multi-Drop Box
16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide
16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide 1. Introduction Thank you for purchasing this 16-Port RS232 to USB2.0 High Speed Multi Serial Adapter. It is an
Cable Guide. Click on the subject to view the information. Digi Cables Building Cables General Cable Information
Cable Guide Click on the subject to view the information. Digi Cables Building Cables General Cable Information Digi Cables Click on the subject to view the information. Digi Connector Options Digi Connector
Model 201 Wiegand Touchpad Reader Installation Guide
Model 201 Wiegand Touchpad Reader Installation Guide P/N 460353001C 15AUG11 2011 UTC Fire & Security. All rights reserved. This document may not be copied in whole or in part or otherwise reproduced without
RS232C < - > RS485 CONVERTER S MANUAL. Model: LD15U. Phone: 91-79-4002 4896 / 97 / 98 (M) 0-98253-50221 www.interfaceproducts.info
RS232C < - > RS485 CONVERTER S MANUAL Model: LD15U INTRODUCTION Milestone s model LD-15U is a RS232 to RS 485 converter is designed for highspeed data transmission between computer system and or peripherals
Instructions on How to Use HyperTerminal to Test Serial Ports ...
Print Date: 04.03.2010 Testing Serial Cards Instructions on How to Use HyperTerminal to Test Serial Ports... Brain Boxes Limited, Unit 3C, Wavertree Boulevard South, Wavertree Technology Park, Liverpool,
RS-232 Baud Rate Converter CE Model 232BRC Documentation Number 232BRC-3903 (pn5104-r003)
S-232 Baud ate Converter CE Model 232BC Documentation Number 232BC-3903 (pn5104-r003) International Headquarters B&B Electronics Mfg. Co. Inc. 707 Dayton oad -- P.O. Box 1040 -- Ottawa, IL 61350 USA Phone
IMMS-CCC. IMMS-CCC Hardwire Central Interface. Installation Instructions
IMMS-CCC IMMS-CCC Hardwire Central Interface Installation Instructions TABLE OF CONTENTS... Choose a Location... 1 Connections... 2 Operations... 3 Software Configuration... 4 Troubleshooting... 5 Loopback
Advanced Data Capture and Control Systems
Advanced Data Capture and Control Systems Tronisoft Limited Email: [email protected] Web: www.tronisoft.com RS232 To 3.3V TTL User Guide RS232 to 3.3V TTL Signal Converter Modules P/N: 9651 Document
Connector and Cable Specifications
APPENDIX B This appendix provides the following cabling and pinout information for the Cisco IAD1101 integrated access device: Console Port Signals and Pinouts Ethernet Connector Pinouts Analog Subscriber
SCREENLOGIC INTERFACE WIRELESS CONNECTION KIT
SCREENLOGIC INTERFACE WIRELESS CONNECTION KIT FOR INTELLITOUCH AND EASYTOUCH CONTROL SYSTEMS INSTALLATION GUIDE IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS Technical
Mini Effect Gizmo. User s Manual. RJM Music Technology, Inc.
Mini Effect Gizmo User s Manual RJM Music Technology, Inc. Mini Effect Gizmo User s Manual Version 1.3 September 26, 2013 RJM Music Technology, Inc. 2525 Pioneer Ave #1 Vista, CA 92081 E-mail: [email protected]
INTRODUCTION FEATURES OF THE ICM
INTRODUCTION The ICM, Internet Control Module, is a remote controller device accessible via the Internet that allows operational access to the IPS (and other base units available). Through the ICM you
PCMCIA 1 Port RS232 2.1 EDITION OCTOBER 1999
232 232232 PCMCIA 1 Port RS232 2.1 EDITION OCTOBER 1999 Guarantee. FULL 36 MONTHS GUARANTEE. We guarantee your interface card for a full 36 months from purchase, parts and labour, provided it has been
Configuring IP to Serial with Auto Answer and Serial to IP
Configuring IP to Serial with Auto Answer and Serial to IP You can configure the AirLink device to: Auto answer incoming TCP/IP or UDP/IP connections and send the packet payload out the AirLink device
No Rainfall Data is Collected
No Rainfall Data is Collected There are a number of issues that can cause the system to not collect rainfall data, from clogged collectors to hardware failure or improper part replacement. The most common
RS-422/485 Multiport Serial PCI Card. RS-422/485 Multiport Serial PCI Card Installation Guide
RS-422/485 Multiport Serial PCI Card Installation Guide 21 Contents 1. Introduction...1 2. Package Check List...2 3. Board Layouts and Connectors...3 3.1 2S with DB9 Male Connectors...3 3.1.1 JP5: UART
Frame Relay Cabling This section describes the cabling and connector pinouts for the Frame Relay cards.
A P P E N D I B Cabling Summary Introduction This appendix contains details on the MG 8850 cabling. Note In all cable references, the transmit direction is away from the switch, and the receive direction
SolarEdge. RS485 Expansion Kit Installation Guide. Version 1.0
SolarEdge RS485 Expansion Kit Installation Guide Version 1.0 Disclaimers Disclaimers Important Notice Copyright SolarEdge Inc. All rights reserved. No part of this document may be reproduced, stored in
Extender for HDMI Long Range. www.gefentv.com GTV-HDMI-CAT5LR. User Manual
Extender for HDMI Long Range GTV-HDMI-CAT5LR User Manual www.gefentv.com Technical Support: Telephone (818) 772-9100 (800) 545-6900 Fax (818) 772-9120 Technical Support Hours: 8:00 AM to 5:00 PM Monday
FOM-5A, 6A. Asynchronous Fiber Optic Modem
FOM-5A, 6A Asynchronous Fiber Optic Modem FEATURES Asynchronous transmission at up to 19.2 kbps Transmission range up to 3 km (1.8 mi), regardless of data rate Full- or half-duplex Transfers one control
s!nus-elektrotechnikai bt. Industrial IT & Automation
USB/PPI+ Optoelectronic isolated USB/PPI adapter Optoelectronic isolated USB/PPI adapter, can replace Siemens 6ES7 901-3DB30-0XA0, the largest communication distance of up to 2 kilometers. Not support
LED Wiring and Connections
LED Wiring and Connections A Handbook of How-to Manuals 2009 usledsupply. All Rights Reserved. Index These step by step how to manuals will give you the foundation necessary to use your new LED lights.
Comtrol Cable User Guide
Comtrol Cable User Guide Trademark Notices Comtrol and DeviceMaster are trademarks of Comtrol Corporation. PortVision is a registered trademark of Comtrol Corporation. Microsoft and Windows are registered
User Manual IC-485AI 2002-09-27
User Manual IC-485AI Note: This equipment has been tested and found to comply ith the limits for a Class A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
EQUIPMENT SPECIFICATIONS
EQUIPMENT SPECIFICATIONS IC-1600 Intelligent Controller The IC-1600 Intelligent Controller is a fully intelligent panel that has a complete database on board. It operates in conjunction with the Access
IPG/7700 Hardware Manual SYSTECH. Document number 80-001099-7 Revision A
IPG/7700 Hardware Manual SYSTECH C O R P O R A T I O N Document number 80-001099-7 Revision A Created 2010, and Protected Under the U.S. Copyright Act of 1976. Copyright 2010, SYSTECH Corporation All Rights
Integration Note. Manufacturer: OVERVIEW AND SUPPORTED FEATURES. OMNISTAT 2 (RC-1000 and RC-2000) WIRED MODELS ONLY.
Manufacturer: Model Number(s): Minimum Core Module Version: Comments: HAI Document Revision Date: 4/18/2013 OMNISTAT 2 (RC-1000 and RC-2000) WIRED MODELS ONLY Firmware V. 1.03 Tested Integration Note OVERVIEW
How to setup a serial Bluetooth adapter Master Guide
How to setup a serial Bluetooth adapter Master Guide Nordfield.com Our serial Bluetooth adapters part UCBT232B and UCBT232EXA can be setup and paired using a Bluetooth management software called BlueSoleil
OPT-700 - SERIAL TO FIBER OPTIC CONVERTER
USER S MANUAL OPT-700 - SERIAL TO FIBER OPTIC CONVERTER JUL / 05 OPT-700 VERSION 1 TM FOUNDATION OPT700ME smar www.smar.com Specifications and information are subject to change without notice. Up-to-date
Balun Bulletin- CCTV Systems- Termination
Balun Bulletin- CCTV Systems- Termination Baluns- CCTV Types 1 Balanced Cables: Category Cables 2 Balanced Cables: V/Cat 3 Connecting Balanced Lines 4 Unbalanced Cables: Coax 5 Connecting Unbalanced Lines
Connectors and Cables
APPENDIX B This appendix describes the connectors, cables, and adapters that you use to connect the switch to other devices. Connector Specifications 10/100 Ports The 10/100 Ethernet ports use standard
SVA025 Netcom2 FAQ Rev 1. Mitsubishi Netcom 2 FAQ
SVA025 Netcom2 FAQ Rev 1 Mitsubishi Netcom 2 FAQ SVA025 Netcom2 FAQ Rev 1 2 What series of Netcom did we purchase? Netcom 2 FAQ Mitsubishi has several different versions of communications available. 1.
OMX-RS232 Control Interface
GAFIK Systems Control Interface omx-rs- 09..0 Description Integrates GAFIK 000/6000/7000 Systems with a touchscreen or other digital equipment that supports S communication. Provides S monitoring commands
5 Printing Reports and Labels
Printing Reports and Labels 5 1 5 Printing Reports and Labels 5.1 Printing Cable Documentation Print complete documentation on any cable you test, or any cable in the database. Each page includes the wiring
INSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS Accessory Application Publications No. ACCORD All 30209 2-AND 4-DOOR SYSTEM (VP, LX, SE) Issue Date AUG 2005 PARTS LIST Security System Attachment: P/N 08E55-SDA-100A Unit panel
Serial/ Parallel Combo PCi Card user manual
Serial/ Parallel Combo PCi Card user manual Model 158251 MAN-158251-UM-0409-02 introduction Thank you for purchasing this MANHATTAN Serial/Parallel Combo PCI Card, Model 158251. Compatible with most RS-232
UPGRADING AND SERVICING GUIDE
UPGRADING AND SERVICING GUIDE HPTouchSmart 610 PC Computer features may vary by model. Removing and Replacing a CD/DVD Drive...2 Removing the CD/DVD Drive... 2 Installing a New CD/DVD Drive... 5 Removing
RMS U GSM USB GSM Modem
RMS U GSM USB GSM Modem 2012 CONTEG, spol. s r.o. All rights reserved. No part of this publication may be used, reproduced, photocopied, transmitted or stored in any retrieval system of any nature, without
2-Port RS232/422/485 Combo Serial to USB2.0 Adapter (w/ Metal Case and Screw Lock Mechanism) Installation Guide
2-Port RS232/422/485 Combo Serial to USB2.0 Adapter (w/ Metal Case and Screw Lock Mechanism) Installation Guide 1. Introduction Thank you for purchasing this 2-Port RS232/422/485 Combo Serial to USB Adapter.
Technical Note A007 Modbus Gateway Vantage Pro2 25/09/2009 Rev. A 1 de 7
1 de 7 1. Introduction This Technical Note explains how to configure the Modbus Gateway for Vantage Pro2. The Modbus Gateway allows the easy connection of a PLC (Programmable Logic Controller), RTU (Remote
Installation & User Guide
For use with: Power Pucks Amplifier System (p/n: 2120-0149) Power Pucks + 5-1/4" Coaxial Speakers (p/n: 2120-0151) Power Pucks + 6-1/2" Coaxial Speakers (p/n: 2120-0152) Installation & User Guide Specifications:
HDCATS-100. Installation Guide
HDCATS-100 Installation Guide 1 Contents Description... 3 Features... 4 Application Diagram... 4 Installation... 5 Local HD port... 6 IR Configuration... 7 Serial Data(RS232)... 8 Ethernet Data... 9 Specifications...
Using the Parani SD1000U/SD1000 with Carlson SurvCE
Using the Parani SD1000U/SD1000 with Carlson SurvCE Table of Contents Installing the Radio Driver...2 Pair the Radios...3 Connecting the Radio to the Total Station...4 Configuring SurvCE...5 Parts List...6
Schneider Automation Modbus Plus Network Installing Clustered Node Devices 31000939 00 Version 2.0
Schneider Automation Modbus Plus Network Installing Clustered Node Devices 3000939 00 Version.0 Modbus Plus devices must be installed as specified in a network layout plan, showing each device s mounting
Draper Low Voltage, Remote Control, Serial and Network Wiring Guide
Draper Low Voltage, Remote Control, Serial and Network Wiring Guide Copyright 2007 Draper Inc. Form LV-RC-Serial-Network_Wiring07 Print ed in U.S.A. Draper Low Voltage, Remote Control, Serial and Network
Global Water Instrumentation, Inc.
Global Water Instrumentation, Inc. 11390 Amalgam Way Gold River, CA 95670 T: 800-876-1172 Int l: (916) 638-3429, F: (916) 638-3270 6 Tipping Bucket: RG200 02/05/10 01-343 - 1 - Congratulations on your
FlexPoint T1/E1 Copper to Fiber Line Driver
BLACK BOX NETWORK SERVICES MT660A-MM MT661A-SM MT660A-MM-E MT661A-SM-E FlexPoint T1/E1 Copper to Fiber Line Driver CUSTOMER Order toll-free in the U.S.: Call 877-877-BBOX SUPPORT (outside U.S. call 724-746-5500)
STATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625 METRIC SPECIFICATIONS FOR RS232 LEASED LINE MODEMS (LOW SPEED MODEL 400)
STATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625 METRIC SPECIFICATIONS FOR RS232 LEASED LINE MODEMS (LOW SPEED MODEL 400) N.J. Specification No. Effective Date: July 1, 2001 New
Communication Setup Application Note
Communication Setup Application Note This Application Note describes how to install and set up communication between the inverter and the SolarEdge Monitoring Server. This document contains the following
MS830 / MS833 Barcode Reader v1.0 9-December-2014
MS830 / MS833 Barcode Reader v1.0 9-December-2014 Publication Information 2014 Imagine Communications Corp. Proprietary and Confidential. Imagine Communications considers this document and its contents
System Wiring Design Guide
System Wiring Design Guide This guide will help demonstrate the various types of wiring solutions available when connecting video surveillance cameras to EZ Watch Pro and Armor Pro Digital Video Recorders.
Instructions - THP-700RTS Telephone Headset Radio Transfer Switch with Dry Switch Closure Output
This document applies to all THP-700RTS family members Instructions - THP-700RTS Telephone Headset Radio Transfer Switch The THP-700RTS is an interface between telephones or Automatic Call Directors and
Model 2120 Single Port RS-232 Terminal Server Frequently Asked Questions
Applications What are some of the applications for the Model 2120 Single Port Terminal Server? The Patton Single Port RS-232 Terminal Server provides the ability to bring virtually any RS-232 device onto
Network Cabling Guide
Network Cabling Guide Poor or incorrectly installed network cabling can cause numerous problems with your computer network. Whilst we recommend that you employ a network / cabling specialist to wire and
Technical Note #14. Phone Modem Device Support. GE ED&C Home Search ED&C GE ED&C Power Management Home GE ED&C PMCS Home
1 of 7 GE ED&C Home Search ED&C GE ED&C Power Management Home GE ED&C PMCS Home GE Power Management Control System Description Software Hardware Operation Product Support Operator Interfaces F A Q s App
ALL-USB-RS422/485. User Manual. USB to Serial Converter RS422/485. ALLNET GmbH Computersysteme 2015 - Alle Rechte vorbehalten
ALL-USB-RS422/485 USB to Serial Converter RS422/485 User Manual ALL-USB-RS422/485 USB to RS-422/485 Plugin Adapter This mini ALL-USB-RS422/485 is a surge and static protected USB to RS-422/485 Plugin Adapter.
Technical Manual. For use with Caller ID signaling types: Belcore 202, British Telecom, & ETSI
Technical Manual For use with Caller ID signaling types: Belcore 202, British Telecom, & ETSI Caller ID.com WHOZZ CALLING? POS 2 Caller ID Monitoring Unit Technical Manual For use with Caller ID signaling
CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)
TECHNICAL DATASHEET #TD1102AX CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version) Part Number: Connector Amplifier CAPV-H-4-20MA-x complete with cable CAPV-4C-yM Where: x = current output
Hardware Installation and Configuration Guide
Hardware Installation and Configuration Guide Trademark Notices Comtrol, DeviceMaster, and PortVision are registered trademarks of Comtrol Corporation. Ethernet is a registered trademark of Digital Equipment
When we look at the connector pinout of the RS232 port, we see two pins which are certainly used
1 Null modem - an introduction Serial communications with RS232 1. One of the oldest and most widely spread communication methods in computer world. The way this type of communication can be performed
PL-1, Pocket Logger 11-0135B
PL-1, Pocket Logger 1 PL-1... 2 2 Wiring... 3 2.1.1 Single Innovate Device Relay Wiring Instructions... 3 3 Mounting... 4 4 Connecting the PL-1 to the MTS serial chain... 4 5 Recording... 5 6 LogWorks...
Options for ABB drives, converters and inverters. User s manual FDPI-02 diagnostics and panel interface
Options for ABB drives, converters and inverters User s manual FDPI-02 diagnostics and panel interface Table of contents Table of contents 3 1. FDPI-02 diagnostics and panel interface Safety..............................................
QSE-CI-DMX Control Interface
Control Interface 369372c 1 04.05.16 Description The operates either in a standalone QS system or a Quantum system. It performs different functions depending on the system in which it is operating. QS
RJ45 Shielded (standard) port pinout. CS9000, Jetstream 4000 + 8500, Lanstream 2000, RTA8/RJX, RRC16, MTA8/RJX & SXDC8/RJX
Shielded (standard) port pinout Pin Circuit Function 1 DCD Input Data Carrier Detect 2 DSR Output Data Set Ready 3 DTR Input Data Terminal Ready 4 S/GND Signal Ground 5 TXD Output Transmit Data 6 RXD Input
Model CFA-24 Transparent Cable Farm Automation Switch
Model CFA-24 Transparent Cable Farm Automation Switch Ideal for Broadband Forum s ID-337 G.fast Certification and TR-249 VDSL2 Vectoring Testing High performance transparent solution designed to automate
GEU-0822 8-Port Gigabit Switch
GEU-0822 8-Port Gigabit Switch 1 V1. 1_20150622 1. INTRODUCTION... 3 1.1 Product Briefs... 3 1.2 Product Features... 3 1.3 Hardware Introduction... 4 2. CONNECTING THE SWITCH... 5 2.1 Package Contents...
Building A Computer: A Beginners Guide
Building A Computer: A Beginners Guide Mr. Marty Brandl The following was written to help an individual setup a Pentium 133 system using an ASUS P/I- P55T2P4 motherboard. The tutorial includes the installation
s!nus-elektrotechnikai bt. Industrial IT & Automation
USER MANUAL s!nus-elektrotechnikai bt. USB/PPIM+ Siemens S7-200 USB/PPI Multi-Master Cable USB/RS485 Isolated For all PPI-Bus System Summary: USB / PPIM + is the PPI Multi-Master programming Cable which