MEDIUM VOLTAGE CABLES Up to and including 36 KV



Similar documents
OPTICAL FIBER CABLES

MV CABLE TYPE C

Gulf Cable & Electrical Ind. Co.

Quality Reliability Innovation. ISO 9001 : 2000 CERTIFIED BY AFAQ No. QUAL / 1997 / 7034 a COPPER TELECOMMUNICATION CABLES

3.6/6 kv XLPE insulated cables 5. 6/10 kv XLPE insulated cables /15 kv XLPE insulated cables /20 kv XLPE insulated cables 35

High Voltage Systems. Today. The history of cables

CONFLEX ELECTRIC CABLE

MEDIUM VOLTAGE POWER CABLES

Cables, Cable Laying & Accessories Manual

KNOW YOUR OPTIONS: 230 KV POWER CABLES

6 ELECTRICAL PARAMETERS

KNOW YOUR OPTIONS: 69 KV XLPE POWER CABLE

Section kv Power Cables

UGVCL/SP/591/11KV HT AB CABLE

Network Standard Advice No. 1420C 9/6/2011

INTERNATIONAL STANDARD

Corporate Profile ROYAL. MODERN ROYAL ELECTRIC Ideal Power Solution MRE ELECTRICAL, INSTRUMENTATION & COMMUNICATION SYSTEMS

THE PATHWAY TO POWER HIGH-VOLTAGE CABLES

SCHEDULE ' A ' TECHNICAL SPECIFICATION FOR SINGLE CORE,UNARMOURED L.T.XLPE POWER CABLE FOR DISTRIBUTION NETWORK IN MAHARASHTRA

FIRE RESISTANT CABLE CONSTRUCTION OF CABLES

Fault location on power cables. Fault location on power cables

Removal of EP SP High Voltage Cable

LOW VOLTAGE POWER CABLES

SCHEDULE ' A' TECHNICAL SPECIFICATION FOR 11/22/33KV H.T.XLPE POWER CABLE FOR DISTRIBUTION NETWORK IN MAHARASHTRA (SPECIFICATION NO.

APPLICATION ORIENTED DESIGN OF CABLES

EDS KV TRIPLEX CABLE

Specializing in the cable business for over 38 years, PT. SUPREME CABLE

Power and Wiring Cables

XLPE рower cables. 2 Modern solutions for power cables I Estralin HVC

ScottishPower Distribution Cables & Equipment. Metal Theft

XLPE Land Cable Systems User s Guide. Rev 5

We specialize in low voltage cables including: Stranded Single Cable H07V-R Flexible Single Cable H05V-K

COAX Cables Radio Frequency Cables

The Quality Connection. BETAflam Fire Resistant Safety Cables

Fire Resistant Cables

4 IX D N E P P A Installation methods Current-carrying capacity and voltage drop for cables Reference method IET Wiring Matters

Gulf Cable & Electrical Ind. Co.

LEAD FREE FIREX. Interlock Armored Cables TECK90 and MC Industrial Cables. w w w. n e x a n s e n e r g y. c o m

VIPERFLEX ELECTRIC CABLE

T A B L E T 1 T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A

6-36kV Medium Voltage Underground Power Cables. XLPE insulated cables

HINDUSTAN PETROLEUM CORPORATION LIMITED ENGINEERING & PROJECTS GRESHAM ASSURANCE HOUSE, 2 ND FLOOR, A-1595(3) 1-A, SIR P M ROAD, FORT MUMBAI

EARTHING AND BONDING AT SECONDARY SUBSTATIONS

TECHNICAL SPECIFICATION OF 11 / 22 KV XLPE POWER CABLE FOR SUB-STATION

ENERGY. TECWATER S1BN8-F 0,6/1 kv. Cable for Water Application

Temperature Permissible ambient temperature. Weather Resistance to severe weather conditions. Impacts Cable mechanical resistance to impacts

CURRENT RATINGS MORE THAN A CABLE

LT/HT Power & Control Cables

Current Ratings. TABLE BEC 107. (Continued) Current ratings for 6350/11000 volts grade PILC/SWA/PVC cable to BS6480/69

FLEXIBLE INDUSTRIAL CABLES H07RN-F TENAFLEX SR

Global cable expertise for rolling stock

FOREWORD ONE OF THE WORLD S BIGGEST COMPANIES IN THE SECTOR.

Fibre optic cables MDIC LSZH

100% EMI Emission Containment

Outside Telephone Cable

CABLES FOR PHOTOVOLTAIC SOLAR ENERGY INSTALLATIONS FOR CLEAN ENERGY

Tri-Rated Flexible PVC Equipment Wire

FIRE RESISTANT CABLES FP200 GOLD

VOLTS - Copper conductor PVC insulated SSA 1320, IEC & BS 6004 HO 7V - U With Solid Conductor - TYPE IEC 01. Insulation Thickness

International Electrotechnical Commission Standards

Building Cables and Wires

PROFIBUS cable. PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications

Session 14 Cable Support Systems

The Contractor shall furnish and install all shielded power cable suitable for use on this project.

Voltage Drop (Single-Phase)

AFUMEX LSX LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 BASEC APPROVED PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:

Marine & Shipboard Cable JIS C 3410(1999) IEC , 353, 354, 376

SECTION SIGNAL WIRE AND CABLE

HIGH VOLTAGE XLPE CABLE SYSTEMS. Technical User Guide

Contents. All Rights Reserved

e-mobility Special cables for electric vehicles Coroplast Fritz Müller GmbH & Co. KG Tapes Cables Cable Assemblies

RADOX railway cables acc. to EN and EN Edition 2009

BETAtrans. Cables and Systems for Rolling Stock. Edition 2006

High Voltage Cable Systems

DOUBLE STAINLESS STEEL TUBE DTS FIBER OPTIC CABLE FTSF-FSUTS(DTS)

Airdac CNE and SNE, 600/1000V, Polyethylene Sheath, SANS 1507, NRS 063 & NRS 017

TECHNICAL SPECIFICATION FOR LOW-FREQUENCY CABLES AND WIRES WITH PVC INSULATION AND PVC SHEATH

TECHNICAL SPECIFICATIONS OF 66 KV 1C 300 SQ.MM. XLPE POWER CABLE FOR UNDER GROUND LINE

TECHNICAL SPECIFICATIONS OF 66 KV 1C 630 SQ.MM. XLPE POWER CABLE FOR UNDER GROUND LINE

The color scheme for the fibers in the cable complies with the Telcordia (formerly Bellcore) specification.

2 8 k V, 1 / C, T R X L P E I N S U L A T E D, F L A T S T R A P S H I E L D E D C A B L E, C O M P R E S S E D S T R A N D I N G

Festoon 715 P PUR cable for flexible application in festoon systems

Catalogue Câbles d Energie

IEEE POWER ENGINEERING SOCIETY CHICAGO CHAPTER THE OKONITE COMPANY WEDNESDAY JANUARY 11, 2006 JIM FITZGERALD ENGINEERING LINGO

Offshore Transformer Platform. Technical Standard. Energinet.dk. HV, MV, LV and Signal Cables and Cable Routing

Comparative study for cables and busbars

The Quality Connection. Cable Solutions for Mobile Networks Business Unit Telecom

Important Information: Complete Terms and Conditions are printed on sales invoices

Session Five: Modern XLPE Materials for Extruded Energy Cable Systems

David O Brien, CMP Products (David.OBrien@cmp-products.com)

ISO 9001 ISO CABLES AND WIRES CATALOGUE 2008

Flygt flexible cables

Communication, Signal & Data Cables

Specification SFTP CAT6 Network Cable 23AWG CU

Sizing conductors and selecting protection devices

RF & Microwave cable assemblies C291

R=Required by Lab S=May be subcontracted IEC SYSTEM FOR CONFORMITY TESTING AND CERTIFICATION OF ELECTRICAL EQUIPMENT COMMITTEE OF TESTING LABORATORIES

Flexible cables for submersible products

Flexible Control Cables

Transcription:

MEDIUM VOLTAGE CABLES Up to and including 6 KV

NOTICE As this catalogue is not intendedto cover all of LIBAN CABLES SAL possibilities in special cables manufacturing, the hereafter listing of the types of cables is not retrictive but only indicative of the main and most current types we manufacture. On the other hand, our specification sheets are inspired mainly from International Electrotechnical Commision Specification (IEC) only in order to conform with the sustained trend, noticed both regionally and worlwide, towards these same IEC supposed to inspire any further standardization approaches. Whereas, in facts some special cables may require special conception, fully within the capabilities of LIBAN CABLES SAL, ISO 900 certified, precisely because in position to conceive / tailor your special needs. That is why, while consulting this brochure, it is important to take into account that any combination or change of the constructional details mentioned in this catalogue remain feasible, on base of special conception / development, matching any special or different specifications. Finally, and within our policy of constant improvement, we reserve the right to alter any part of the information contained in this publication without incurring any obligation. In all cases this brochure being only indicative, and unless expressly agreed upon, it cannot be considered by any mean as contractual document. 6

INTRODUCTION Devoted to the manufacturing of electric and telecom cables, Liban Cables is the first and largest supplier in Lebanon and a leader in the MiddleEast region. Liban Cables was founded in 968 by a group of Lebanese industrialists backed up by the technical assistance of two international leading firms : Les Cables de Lyon France Phelps Dodge U.S.A Staffed with qualified engineers and highly skilled technicians, our plant is located in NahrIbrahim at 0 Km from Beirut, where cables are designed and manufactured according to all international specifications : IEC, VDE, UTE, BS, and others on customer request. Early after its foundation, Liban Cables has become the major supplier of the Lebanese market in both the public and private sectors. The product range of Liban Cables covers all electric cables up to 45 KV, communications cables (copper and optical fiber) in addition to a wide variety of special cables manufactured on customer request. High quality cables, continuous developments of the production range, direct and fast shipments have contributed in rendering Liban Cables an important exporter for many countries on the three limitrophe continents (Asia, Europe, Africa). Liban Cables products are particularly appreciated by administrations and international contractors operating in the region and seeking reliable and direct supplies of power and communication cables. 7

CONTENTS Page 4 NOTICE INTRODUCTION QUALITY ASSURANCE RECOMMENDED ORDERING PARAMETERS GENERALITIES : 6 7 8 8 9 4. 4. 4. 4.. 4.. 4.4 4.6 4.7 4.8 Choice of voltage Determination of the al area Current carrying capacities Buried cables Cables laid in the air Inductance Capacitance Conductors short circuit current Screen short circuit current Minimum bending radius 9 9 9 0 4 4 5 6 7 OUR TYPE AND CODE DESIGNATION SINGLE AND THREE CORE MEDIUM VOLTAGE CABLES According to international standard IEC 60 6..8/ (.6) KV Cables, XLPE insulated, PVC or PE sheathed 6. XLPE insulated, screened, PVC or PE sheathed cables for voltages up to and including 6 KV. 6. Insulated Bundled overhead conductors (Torsade) /0 (4) KV XLPE TECHNICAL INFORMATION 7. 7. Formulae Conversion factors and units 5 6 6 40 4 4 4

QUALITY Step by step, from raw material to final product, quality constitutes a major concern to Liban Cables. Raw material are continuously and repetitively tested from trial orders till the last batch received afterwards. In addition to the final tests carried out on finished products, work in process is already tested within two simultaneous procedures : A built in quality control system carried out by the production itself at any step of work in process. A parallel and contradictory procedure is also carried out on the same stages and products by independent inspectors reporting to the quality control service. End users and/or third part inspection authorities are also constantly commissioning the finished products and assessing the strict conformity to ordered specifications. In fact, our ISO 900 certification stated in Feb 997 by the International Certification Network (EQNET) is certified by the French Association for Quality Assurance (AFAQ), the well known rigourous and independant accredited European assessor. This certification, under reference AFAQ Nº QUAL / 997 / 4, confirms the soundness and the performance of the Quality System we apply for the Design, the Development, the Manufacturing and the Marketing & Sales of all our products. RECOMMENDED ORDERING PARAMETERS For prompt quotation / supplies please make sure your inquiries and your orders are securing the following data : International or Special Standard. (Alternatively, the precise usage of the cable.) Rated voltage. Copper or Aluminium conductors. 4 Size of each conductor. 5 Insulation material : XLPE or others. 6 Number and identification of conductors. 7 Other requirements. 8 Packing. 9 Required delivery time. 0 Required validity. 8

4 GENERALITIES 4. CHOICE OF VOLTAGE The rated voltage is specified as Uo / U where : Uo is the rated voltage between conductor and screen or outer metallic protection. U the rated voltage between any two conductors. In three phase systems Uo is U / The voltage of the cable must be chosen according to the maximum voltage Um in normal working conditions, which must not exceed the rated voltage by more than 0%. The following table gives the maximum permissible operating voltage relative to each rated voltage (Uo / U). Rated voltage Uo / U (Kv).8 /.6 / 6 6 / 0 8.7 / 5 / 0 8 / 0 Max. voltage Um (Kv).6 7. 8 4 6 4. DETERMINATION OF THE CROSS SECTIONAL AREA The determination of the al area depends on the : Current carrying capacities in continuous loading, Permissible shortcircuit current, Conditions of installation (temperature, spacing,...). 4. CURRENT CARRYING CAPACITIES The heat produced by the cable under the set conditions must be able to dissipate to the ambient environment at any point of the cable installation; therefore the loading of the cable must be limited accordingly. The current carrying capacities shown in the electrical characteristics tables are calculated according to the internationally adopted method of the IEC publication 6087 for a maximum core temperature of 90 C, at the following installation conditions : 9

4... BURIED CABLES The stated values are for cables or ducts placed in the ground at a depth of 800 mm of average thermal resistivity of 00 C.cm/w and spaced so that the temperature rise in each duct has no effect on the other ducts ( space being greater than meter ), for a soil temperature of 0 C. Where the thermal resistivity is different (not 00 Ccm/w) the current rating should be multiplied by the correction factors shown in the following table. Correction factor for different soil thermal resistivity Nature of the soil Very wet soil Normal soil Dry soil Very dry soil Soil thermal resistivity C.cm/w 40 85 00 0 00 Correction factor....05.00 0.94 0.86 0.76 0. 0.65 Where the temperature of the soil is different (not 0 C) the current rating should be multiplied by the following correction factors. Correction factor for different soil temperature Soil temperature ( C) Carrying core temperature ( C) 0 5 0 65.0.5..8.4.0 75.7..09 80.5..08 85.4..07 90..0.07..0.06 00..09.06 05..08.06 5 0 0 40 45.05 0.94 0.88 0.8 0.75 0.67 0.58.05 0. 0.89 0.84 0.77 0.7 0.6.04 0. 0.90 0.85 0.80 0.74 0.67.04 0.96 0.9 0.87 0.8 0.76 0.7.04 0.96 0.9 0.88 0.8 0.78 0.7.04 0.96 0.9 0.89 0.85 0.80 0.76.0 0.97 0.9 0.89 0.86 0.8 0.77.0 0.97 0.94 0.90 0.87 0.8 0.79.0 0.97 0.94 0.9 0.87 0.84 0.80 0

When several cables or ducts are laid underground with less than one meter spacing the current rating values should be multiplied by the following correction factors : Correction factor of proximity effect for underground cables Single or multicore cables Number of circuits 4 5 6 Touching cables 0.76 0.64 0.57 0.5 0.49 One diameter spaced cables a = D 0.79 0.67 0.6 0.56 0.5 a = 0.m a = 0.5m a =.0m 4... CABLES LAID IN AIR : The stated values are for cables or ducts laid in air with an ambient temperature of 0 C and out of direct sunlight, spaced so that the temperature rise of individual cables has no influence on others. The spacing between adjacent cables is at least twice the cable or duct diameter. When the ambient temperature is different ( not 0 C ) the current rating values should be multiplied by the following correction factors : Correction factor for different ambient temperature Ambient temperature ( C) 0 5 0 5 0 0 40 45 55 60 65 75 80 85 90 00 D = overall outer sheath diameter 0.84 0.74 0.69 0.65 0.60 0.88 0.79 0.75 0.7 0.69 a = Space between cables 0.9 0.85 0.8 0.80 0.78 Carrying core temperature ( C) 65 75 80 85 90 00 05.6...0..07 0.9 0.85 0.76 0.65 0.5 0.8..7..7..06 0.94 0.87 0.79 0.7 0.6 0. 0..9..0.5..05 0.94 0.88 0.8 0.75 0.67 0.58 0.47 0..6..8.4.0.05 0. 0.89 0.84 0.77 0.7 0.6 0.55 0.45 0..4..7..09.04 0. 0.90 0.85 0.80 0.74 0.67 0.60 0.5 0.4 0.0..9.5..08.04 0.96 0.9 0.87 0.8 0.76 0.7 0.65 0.58 0. 0.4 0.9..8.4..07.04 0.96 0.9 0.88 0.8 0.78 0.7 0.68 0.6 0.55 0.48 0.9 0.8.0.6..0.07.04 0.96 0.9 0.89 0.85 0.80 0.76 0.7 0.65 0.60 0.5 0.46 0.8 0.7.8.5..0.06.0 0.97 0.9 0.89 0.86 0.8 0.77 0.7 0.68 0.6 0.58 0.5 0.45 0.7 0.6

When several cables or ducts are grouped, the current ratings values should be corrected as follows : a D H SINGLE CORE CABLES Method of laying Touching One diameter spaced cables a = D Number of layers Number of ducts 0.97 0.94 0.9.0 0.97 0.96 0.89 0.85 0.84 0.98 0.9 0.9 0.87 0.8 0.79 0.96 0.89 0.86 cables in horizontal layer cables in triangular formation MULTICORE CABLES Method of laying Touching One diameter spaced cables a = D Number of layers Number of ducts.0.0.0.0.0.0 0.88 0.87 0.86.0 0.98 0.98 0.8 0.80 0.79 0.98 0.86 0. 4 0.78 0.76 0.75 0. 0.9 0.9 6 0.76 0.7 0.7 0.9 0.87 0.85 Note : the space H between layers must not be less than 0cm

4.4 Inductance The Inductance L depends on the geometrical characteristics of the cable as well as the disposition of conductors for unarmoured cables : L = 0.05 + 0.46 Log Dm 0 ( mh / Km ) r where : r = Conductor Radius D = Distance between Conductors Single phase system Three phase system flat formation Three phase system trefoil formation D D D D D D Dm = D Dm =,6 D Dm = D For armoured Cables increase the inductance of about 0% Capacitance C =. 8 Ln D d d = Diameter of conductor ( including the eventual semiconductive layer ) D = Diameter of insulated Conductor 4.6 Conductors short circuit current : Current densities given in the table below are in (A / mm ), for a maximum condutor temperature of C at the end of the short circuit. Temperature of conductor before overload T ( C ) 0 0 90 0. 556 57 464 49 0.5 49 4 07 96 Current density ( A / mm ) Conductor metal Copper Aluminium overload time in secs 5 0. 0.5 76 4 78 66 64 6 0 76 4 59 47 0 65 45 0 9 98 6 87 8 9 For an overload duration (t) different than those figured in the above table, the correspondant current density is given by the following formula : Current density for a duration (t) = Current density for sec t 8 79 7 64 5 5 46 40

4.7 Screen shortcircuit current Following shortcircuit current in Ampere, are approximative, calculated for copper tape screen of 0.mm thickness applied helically with about 0% overlapping. Conductor 0.5 second second seconds Specified Voltage, KV in mm 8.7/5(8) /0(4) 8/0(6) 8.7/5(8) /0(4) 8/0(6) 8.7/5(8) /0(4) 8/0(6) 6 0 85 5 6 7 9 00 9 800 800 800 000 0 900 600 9 0 00 7 9 00 600 0 800 9 4 6 7 8 9 4 7 9 000 0 0 900 0 900 90 9 000 400 800 900 0 0 0 00 4 800 9 00 5 800 8 90 4 4.8 Minimum Bending Radius : Listed values represent the permanent bending radius the cables withstand in fixed installation and on dispatching reels. Other constraints may impose greater bending radius. Cable on drum Cable during installation Installed Cable Armoured single core 8 D 6 D 8 D Unarmoured single core 0 D 0 D 0 D Armoured multi core 7 D 6 D 7 D Unarmoured multi core 8 D 6 D 8 D D = Overall diameter in mm 4

5 OUR TYPE AND CODE DESIGNATION The type designation is a combination of abbreviations indicating the type, voltage and the main constructional elements of the cable as follows : The first symbol is the letter M for medium voltage cables The second symbol is a number (n) from to 6 indicating the voltage as follows : 4 5 6 for for for for for for.8/ (.6).6/6 (7.) 6/0 () 8.7/5 (8) /0 (4) 8/0 (6) KV KV KV KV KV KV The third symbol is a letter indicating the type of the metal as follows : N for copper conductor A for aluminium conductor The fourth symbol is a number indicating the type of the screen as follows : for semiconductor tape plus copper tape for semiconductor tape plus copper wire for extruded semiconductor plus copper tape 4 for extruded semiconductor plus copper wire Note : For cables up to and including.6 KV where the screen is not required, this number is not existing. The fifth, sixth and seventh abbreviations are eventual letters indicating the following : L B G RF A W For lead sheath For steel tape armouring For galvanized steel tape armouring For galvanized roumd steel wire armouring For flat steel wire armouring For aluminium tape armouring For round aluminium wire armouring Example : MAB Medium voltage cable, 6/0 () KV, aluminium conductor, XLPE insulation, semiconductor tape plus copper tape screen, steel tape armour. M5NLR Medium voltage cable, /0 (4) KV, copper conductor, XLPE insulation, extruded semiconductor plus copper tape screen, lead sheath, galvanized round steel wire armour. 5

6 SINGLE CORE AND THREE CORE MEDIUM VOLTAGE CABLES According to international standard IEC 60 6..8/ (.6) KV CABLES XLPE INSULATED, PVC OR PE SHEATHED. SCOPE This specification covers single core cables and three core armoured or unarmoured cables, rated at.8/ (.6) KV conforming to IEC 60 Specifications.. CONSTRUCTION. Conductor Plain, annealed electrolytic copper or Aluminium conductors, circular stranded, conforming to the applicable requirements of IEC 608.. Insulation XLPE thermosetting material conforming to the applicable requirements of IEC 60 ( flame retardant XLPE for specific applications ).. Assembly Insulated conductors are laid up, filled where necessary with non hygroscopic material, and covered with an extruded thickness of thermoplastic material, or binding tape..4 Armour Two layers of steel tape, (non magnetic tape for core cables) conforming to the applicable requirements of IEC 60 recommendations. Flat or round wires armouring can be provided upon specific customer requirements. Sheath PVC or PE (halogen free or fire retardant compound on special request) thermoplastic material, conforming to the applicable requirements of IE 60.. TESTS All tests required by the IEC 60 either on Raw material or on finished products. 6

SINGLE CORE CABLES.8 / (.6) KV MN MA 4 MNB MAB 4 5 MNFG MAFG 4 6 MNR MAR 4 7 Stranded copper or aluminium conductor 5 Double aluminium tape armour XLPE Insulation Bedding 4 PVC Sheath 6 7 Flat aluminium strips armour with one aluminium tape applied in helical form Round or flat aluminium wire armour 7

THREE CORE CABLES.8 / (.6) KV MN MA 4 MNB MAB 4 5 MNFG MAFG 4 6 MNR MAR 4 7 Stranded copper or aluminium conductor 5 Double steel tape armour XLPE Insulation Bedding 6 Galvanized flat steel strip armour with flat steel tape applied in helical form 8 4 PVC Sheath Note : Different constructions remain possible on special request. 7 Galvanized round steel wire armour

.8/ (.6) KV SINGLE CORE, XLPE INSULATED, PVC SHEATHED UNARMOURED CABLES Type MN, MA Conforming to IEC 60 DIMENSIONAL CHARACTERISTICS Radial Thickness of Diameters Inner Outer Insulation Sheath 0 6 0 85 400 60 800 000..4.6.8 Approximative net weight Copper cable Aluminium cable Sheath Conductor Insulation Overall Conductor Cable Conductor Cable.4.4.4.4.4.5.5.6.6.7.8.8.9...4.8 4.8 6.0 7.5 8. 0.0.8. 4.8 6.55 8.7. 4. 7..0 7. 4.6 7.8 8.8 0.0.5. 4.0 5.8 7. 8.8 0.55.7. 8..7.8 4. 47. 5 6 8 9 7 9 6 4 47 5 90 4 4 4 608 84 065 07 640 098 646 460 46 56 70 9080 8 4 68 8 85 6 4 98 499 68 804 05 88 758 0 60 00 90 75 475 5 665 805 990 00 8 00 740 Length on drum mm mm mm mm mm mm mm Kg/Km Kg/Km Kg/Km Kg/Km m 90 5 5 455 580 800 060 0 580 9 4 040 90 490 6 80 00 ELECTRICAL CHARACTERISTICS DC Resistance at 0 C* Current carrying capacity ** Underground Cable Cables in air Cables in duct Copper Alu 000 000 000 Copper Alu Copper Alu Copper Alu mm Ω/Km Ω/Km Amp Amp Amp Amp Amp Amp 0 6 0 85 400 60 800 000.8.5 0.77 0.54 0.87 0.68 0.9 0.5 0.4 0.099 0.0754 0.060 0.04 0.066 0.08 0.0 0.076.08.9.0 0.868 0.64 0.44 0.0 0. 0.06 0.64 0. 0.00 0.0778 0.0605 0.0469 0.067 0.09 90 0 60 0 85 40 85 40 485 560 60 70 800 90 000 085 75 80 0 60 80 440 5 640 740 80 90 65 00 60 40 475 5 6 740 860 990 40 4 75 85 0 80 4 580 680 790 90 0 0 80 05 40 65 00 05 465 5 6 740 855 000 65 40 85 05 55 75 0 65 40 4 580 6 780 90 090 * At different operating T( C) : R = R0 C {+ α (T C 0)} α : Temperature coefficient at 0 C = 0.009 for copper & 0.0040 for aluminium ** Laying conditions : Underground : Temperature of the soil 0 C Thermal resistivity 00 C cm/w In air : Ambient temperature 0 C *** Greater sizes are also available 9

.8/ (.6) KV THREE CORE, XLPE INSULATED, PVC SHEATHED UNARMOURED CABLES Type MN, MA Conforming to IEC 60 DIMENSIONAL CHARACTERISTICS 0 6 0 85 Radial Thickness of Diameters Approximative net weight Inner Outer Copper cable Aluminium cable Insulation Sheath Sheath Conductor Insulation Overall Conductor Cable Conductor Cable.8.8.8.8.9...4.7.8.8 4.8 6.0 7.5 8. 0.0.8. 4.8 6.55 8.7. 7.8 8.8 0.0.5. 4.0 5.8 7. 8.8 0.55.7. 4 6 9 40 4 46 56 6 49 679 94 74 84 5 7 960 4969 67 807 585 7 0 40 80 60 40 4990 6 77 960 8 0 06 86 87 559 776 980 04 9 4 400 6 760 940 0 580 880 0 680 0 40 Length on drum mm mm mm mm mm mm mm Kg/Km Kg/Km Kg/Km Kg/Km m ELECTRICAL CHARACTERISTICS DC Resistance at 0 C* Current carrying capacity ** Underground Cable Cables in air Cables in duct Copper Alu Copper Alu Copper Alu Copper Alu mm Ω/Km Ω/Km Amp Amp Amp Amp Amp Amp 0 6 0 85.8.5 0.77 0.54 0.87 0.68 0.9 0.5 0.4 0.099 0.0754 0.060.08.9.0 0.868 0.64 0.44 0.0 0. 0.06 0.64 0. 0.00 90 0 55 90 75 0 40 4 540 60 75 0 75 5 90 65 4 485 90 0 55 90 80 40 85 445 590 675 90 5 45 75 60 45 465 50 75 00 0 60 90 85 75 40 5 580 65 80 00 45 85 5 4 * At different operating T( C) : R = R0 C {+ α (T C 0)} α : Temperature coefficient at 0 C = 0.009 for copper & 0.0040 for aluminium ** Laying conditions : Underground : Temperature of the soil 0 C Thermal resistivity 00 C cm/w In air : Ambient temperature 0 C 0

.8/ (.6) KV THREE CORE, XLPE INSULATED, PVC SHEATHED, DOUBLE STEEL TAPE ARMOURED CABLES Type MNB, MAB Conforming to IEC 60 DIMENSIONAL CHARACTERISTICS 0 6 0 85 Radial Thickness of Diameters Approximative net weight Inner Outer Copper cable Aluminium cable Insulation Sheath Sheath Conductor Insulation Overall Conductor Cable Conductor Cable.0.0.0......4.5.6.6.8.8.9.9...4.7.8.0.8 4.8 6.0 7.5 8. 0.0.8. 4.8 6.55 8.7. 7.8 8.8 0.0.5. 4.0 5.8 7. 8.8 0.55.7. 4 7 9 40 44 48 5 56 6 67 49 679 94 74 84 5 7 960 4969 67 807 8 060 40 7 00 0 460 0 60 7 900 8 0 06 86 87 559 776 980 04 9 4 6 760 940 0 0 00 480 860 0 90 4660 55 Length on drum mm mm mm mm mm mm mm Kg/Km Kg/Km Kg/Km Kg/Km m ELECTRICAL CHARACTERISTICS DC Resistance at 0 C* Current carrying capacity ** Underground Cable Cables in air Cables in duct Copper Alu Copper Alu Copper Alu Copper Alu mm Ω/Km Ω/Km Amp Amp Amp Amp Amp Amp 0 6 0 85.8.5 0.77 0.54 0.87 0.68 0.9 0.5 0.4 0.099 0.0754 0.060.08.9.0 0.868 0.64 0.44 0.0 0. 0.06 0.64 0. 0.00 90 0 55 90 75 0 40 4 540 60 75 0 75 5 90 65 4 485 90 0 55 90 80 40 85 445 590 675 90 5 45 75 60 45 465 50 75 00 0 60 90 85 75 40 5 580 65 80 00 45 85 5 4 * At different operating T( C) : R = R0 C {+ α (T C 0)} α : Temperature coefficient at 0 C = 0.009 for copper & 0.0040 for aluminium ** Laying conditions : Underground : Temperature of the soil 0 C Thermal resistivity 00 C cm/w In air : Ambient temperature 0 C

6. XLPE INSULATED, SCREENED, PVC OR PE SHEATHED CABLES FOR VOLTAGES UP TO AND INCLUDING 6 KV.. SCOPE This specification covers single core cables and three core cables, armoured or unarmoured, rated at voltages up to and including 6 KV conforming to IEC 60.. CONSTRUCTION. Conductor Plain, annealed electrolytic copper or Aluminium conductors, circular stranded conforming to the applicable requirements of IEC 608.. Conductor Screening Semiconducting layer extruded or lapped, completely covering the conductors, conforming to the applicable requirements of IEC 60 recommendations.. Insulation XLPE thermosetting material conforming to the applicable requirements of IEC 60 ( flame retardant XLPE for specific applications )..4 Insulation Screening Semi conducting layer extruded (bonded or strippable) or lapped, completely covering the insulated conductors, and a copper or aluminium tape or wire completely covering the semiconducting layer, conforming to the applicable requirements of IEC 60 recommendations. N.B.: Lead sheathed cables are also available. Assembly Insulated and screened conductors are laid up, filled where necessary with non hygroscopic material and covered with an extruded thickness of thermoplastic material, or binding tape..6 Armour Two layers of steel tape (non magnetic tape for core cables), conforming to the applicable requirements of IEC 60 recommendation. Flat or round wires armouring can be provided upon specific customer requirements..7 Sheath PVC or PE (halogen free or fire retardant compound on special request) thermoplastic material conforming to the applicable requirements of IEC 60.. TESTS All tests required by the IEC 60, either on raw materials or on finished products.

SINGLE CORE CABLES From 6 to 6 KV MN MA MN MA M4N M4A M5N M5A M6N M6A 7 5 4 MNB MAB MNB MAB M4NB M4AB M5NB M5AB M6NB M6AB 7 8 6 5 4 MNFG MAFG MNFG MAFG M4NFG M4AFG M5NFG M5AFG M6NFG M6AFG 7 9 6 5 4 MNR MAR MNR MAR M4NR M4AR M5NR M5AR M6NR M6AR 7 0 6 5 4 Stranded copper or aluminium conductor Conductor screen XLPE insulation 4 Insulation screen 5 Copper or Aluminium tape or wires screen (or extruded lead sheath) 6 Bedding 7 PVC sheath 8 Double aluminium tape armour Flat aluminium strips armour 9 with one aluminium tape applied in helical form Round or flat aluminium 0 wire armour

THREE CORE CABLES From 6 to 6 KV MN MA MN MA M4N M4A M5N M5A M6N M6A 7 6 5 4 MNB MAB MNB MAB M4NB M4AB M5NB M5AB M6NB M6AB 7 8 6 5 4 MNFG MAFG MNFG MAFG M4NFG M4AFG M5NFG M5AFG M6NFG M6AFG 7 9 6 5 4 MNR MAR MNR MAR M4NR M4AR M5NR M5AR M6NR M6AR 7 0 6 5 4 4 Stranded copper or aluminium conductor Conductor screen XLPE insulation 4 Insulation screen 5 Copper tape screen Notes : Different constructions remain possible on special request. Lead sheathed cables are also available. 6 Bedding 7 PVC sheath 8 Double steel tape armour 9 0 Galvanized flat steel strips armour with flat steel tape applied in helical form Galvanized round steel wire armour

.6/6 (7.) KV SINGLE CORE, XLPE INSULATED, PVC SHEATHED, SCREENED, UNARMOURED CABLES Type MN, MA Conforming to IEC 60 DIMENSIONAL CHARACTERISTICS Radial Thickness of Diameters Inner Outer Insulation Sheath Approximative net weight Copper cable Aluminium cable Sheath Conductor Insulation Overall Conductor Cable Conductor Cable Length on drum mm mm mm mm mm mm mm Kg/Km Kg/Km Kg/Km Kg/Km m 0 6 0 85 400 60 800 000.6.8.0.....4.4.5.5.6.6.7.7.8.8.9....6.8 4.8 6.0 7.5 8. 0.0.8. 4.8 6.55 8.7. 4. 7..0 7. 4.6 9.8 0.8.5 4. 6.0 7.8 9. 0.8 4.9 7.9. 4.9 9.0 45.0 49.6 5 6 7 9 0 4 7 9 7 4 45 5 56 90 4 4 4 608 84 065 07 640 098 646 460 46 56 70 080 0 85 60 755 985 50 80 00 740 40 480 5 60 8 05 8 4 68 8 85 6 4 98 499 68 804 05 88 758 45 85 400 465 560 685 790 90 0 80 5 8 80 780 480 400 ELECTRICAL CHARACTERISTICS DC Resistance at Current carrying capacity ** 0 C* inductance Underground Cables in air Cables in duct Cable Copper Alu Trefoil Flat capacity formation formation Copper Alu Copper Alu Copper Alu mm Ω/Km Ω/Km mh/km mh/km µf/km Amp Amp Amp Amp Amp Amp 0.8.08 0.46 0.646 0.69 90 75 75 80 6.5.9 0.48 0.6 0. 0 05 85 0.77.0 0.96 0.580 0. 60 65 40 05 0.54 0.868 0.84 0.568 0.4 00 65 0.87 0.64 0.64 0.549 0.8 0 80 85 00 55 0.68 0.44 0.46 0.5 0. 85 0 0 0.9 0.0 0.0 0.55 0. 40 60 60 80 05 0 0.5 0. 0. 0.499 0.407 85 40 75 0.4 0.06 0.08 0.49 0.444 40 475 0 85 0.099 0.64 0.0 0.485 0.487 485 80 5 4 465 65 0.0754 0. 0.89 0.474 0.5 560 440 6 5 40 0.060 0.00 0.88 0.47 0.548 60 740 580 6 4 400 0.04 0.0778 0.74 0.459 0.598 70 5 860 680 740 580 0.066 0.0605 0. 0.454 0.6 800 640 990 790 855 6 60 0.08 0.0469 0.6 0.448 0.7 90 740 40 90 000 780 800 0.0 0.067 0. 0.47 0.8 000 80 0 65 90 000 0.076 0.09 0.48 0.4 0.9 090 90 4 0 40 090 * At different operating T( C) : R = R0 C {+ α (T C 0)} α : Temperature coefficient at 0 C = 0.009 for copper & 0.0040 for aluminium ** Laying conditions : Underground : Temperature of the soil 0 C Thermal resistivity 00 C cm/w In air : Ambient temperature 0 C *** Greater sizes are also available

.6/6 (7.) KV THREE CORE, XLPE INSULATED, PVC SHEATHED, SCREENED, UNARMOURED CABLES Type MN, MA Conforming to IEC 60 DIMENSIONAL CHARACTERISTICS 0 6 0 85 Radial Thickness of Diameters Approximative net weight Inner Outer Copper cable Aluminium cable Insulation Sheath Sheath Conductor Insulation Overall Conductor Cable Conductor Cable.6.8.9.....6.7.8.0..8 4.8 6.0 7.5 8. 0.0.8. 4.8 6.55 8.7. 9.8 0.8.5 4. 6.0 7.8 9. 0.8 4.9 7.9 0 8 40 44 48 5 55 59 65 7 49 679 94 74 84 5 7 960 4969 67 807 000 60 9 40 80 4090 4940 58 87 09 8 0 06 86 87 559 776 980 04 9 4 85 945 40 0 50 900 0 690 080 440 5400 Length on drum mm mm mm mm mm mm mm Kg/Km Kg/Km Kg/Km Kg/Km m ELECTRICAL CHARACTERISTICS mm 0 6 0 85 DC Resistance at 0 C* Copper Ω/Km.8.5 0.77 0.54 0.87 0.68 0.9 0.5 0.4 0.099 0.0754 0.060 Alu Ω/Km.08.9.0 0.868 0.64 0.44 0.0 0. 0.06 0.64 0. 0.00 inductance mh/km 0.408 0.78 0. 0.4 0.9 0.0 0.88 0.79 0.7 0.65 0.8 0.6 Current carrying capacity ** Underground capacity Cable Cables in air Cables in duct Copper Alu Copper Alu Copper Alu µf/km Amp Amp Amp Amp Amp Amp 0.69 90 75 90 75 65 0. 0 0 90 00 80 0. 55 0 55 5 0 00 0.4 90 90 45 60 0.8 75 75 90 45 0. 75 80 85 0. 0 5 40 60 85 0.407 90 85 5 0.444 40 445 45 75 0.487 4 65 40 0.5 540 4 590 465 5 0.548 60 485 675 50 580 4 * At different operating T( C) : R = R0 C {+ α (T C 0)} α : Temperature coefficient at 0 C = 0.009 for copper & 0.0040 for aluminium ** Laying conditions : Underground : Temperature of the soil 0 C Thermal resistivity 00 C cm/w In air : Ambient temperature 0 C 6

.6/6 (7.) KV THREE CORE, XLPE INSULATED, PVC SHEATHED, SCREENED, DOUBLE STEEL TAPE ARMOURED CABLES. Type MNB, MAB Conforming to IEC 60 DIMENSIONAL CHARACTERISTICS 0 6 0 85 Radial Thickness of Diameters Approximative net weight Inner Outer Copper cable Aluminium cable Insulation Sheath Sheath Conductor Insulation Overall Conductor Cable Conductor Cable.6.8......4.4.5.6.6.7.8....4.6.8.9.0..8 4.8 6.0 7.5 8. 0.0.8. 4.8 6.55 8.7. 9.8 0.8.5 4. 6.0 7.8 9. 0.8 4.9 7.9 7 40 4 45 49 54 57 6 65 7 79 49 679 94 74 84 5 7 960 4969 67 807 60 9 80 60 4 500 600 700 8 0400 800 8 0 06 86 87 559 776 980 04 9 4 80 6 90 4 960 440 9 4460 6000 7 Length on drum mm mm mm mm mm mm mm Kg/Km Kg/Km Kg/Km Kg/Km m ELECTRICAL CHARACTERISTICS mm 0 6 0 85 DC Resistance at 0 C* Copper Alu Ω/Km Ω/Km.8.08.5.9 0.77.0 0.54 0.868 0.87 0.64 0.68 0.44 0.9 0.0 0.5 0. 0.4 0.06 0.099 0.64 0.0754 0. 0.060 0.00 inductance mh/km 0.449 0.46 0.87 0.67 0. 0. 0.7 0.07 0.99 0.9 0.84 0.8 Current carrying capacity ** Underground capacity Cable Cables in air Cables in duct Copper Alu Copper Alu Copper Alu µf/km Amp Amp Amp Amp Amp Amp 0.69 90 75 90 75 65 0. 0 0 90 00 80 0. 55 0 55 5 0 00 0.4 90 90 45 60 0.8 75 75 90 45 0. 75 80 85 0. 0 5 40 60 85 0.407 90 85 5 0.444 40 445 45 75 0.487 4 65 40 0.5 540 4 590 465 5 0.548 60 485 675 50 580 4 * At different operating T( C) : R = R0 C {+ α (T C 0)} α : Temperature coefficient at 0 C = 0.009 for copper & 0.0040 for aluminium ** Laying conditions : Underground : Temperature of the soil 0 C Thermal resistivity 00 C cm/w In air : Ambient temperature 0 C 7

6/0 () KV SINGLE CORE, XLPE INSULATED, PVC SHEATHED, SCREENED, UNARMOURED CABLES. Type MN, MA Conforming to IEC 60 DIMENSIONAL CHARACTERISTICS Radial Thickness of Diameters Approximative net weight Inner Outer Copper cable Aluminium cable Insulation Sheath Sheath Conductor Insulation Overall Conductor Cable Conductor Cable Length on drum mm mm mm mm mm mm mm Kg/Km Kg/Km Kg/Km Kg/Km m 6 0 85 400 60 800 000 ELECTRICAL CHARACTERISTICS.5.5.6.6.7.7.8.8.9...4.6 4.8 6.0 7.5 8. 0.0.8. 4.8 6.55 8.7. 4. 7..0 7. 4.6.6.8 4. 6. 7.8 9.6..6 4. 6.5 9... 9.4 45.4.0 8 9 4 7 9 6 8 4 46 5 57 4 4 4 608 84 065 07 640 098 646 460 46 56 70 9080 4 565 685 8 0 60 90 0 8 490 4 5 67 85 05 4 68 8 85 6 4 98 499 68 804 05 88 758 40 4 5 645 765 885 000 400 6 940 0 80 4 DC Resistance at Current carrying capacity ** 0 C* inductance Underground Cables in air Cables in duct Cable Copper Alu Trefoil Flat capacity formation formation Copper Alu Copper Alu Copper Alu Ω/Km Ω/Km mh/km mh/km µf/km Amp Amp Amp Amp Amp Amp.5.9 0.45 0.66 0.58 0 0 85 05 80 0.77.0 0.48 0.60 0.8 60 0 5 00 0.54 0.868 0.404 0.588 0.0 00 65 0.87 0.64 0.8 0.568 0.4 0 80 85 00 55 0.68 0.44 0.6 0.548 0.6 85 0 0 0.9 0.0 0.8 0.5 0.89 40 60 60 80 05 0.5 0. 0.0 0.55 0.7 85 40 75 0.4 0.06 0. 0.8 0.45 40 475 0 0.099 0.64 0.4 0.498 0.77 485 80 5 4 465 65 0.0754 0. 0.0 0.486 0.47 560 440 6 5 40 0.060 0.00 0.9 0.478 0.464 60 740 580 6 4 0.04 0.0778 0.79 0.464 0.56 70 5 860 680 740 580 0.066 0.0605 0. 0.454 0.597 800 640 990 790 855 6 0.08 0.0469 0.67 0.45 0.67 90 740 40 90 000 780 0.0 0.067 0.6 0.44 0.787 000 80 0 65 90 0.076 0.09 0. 0.46 0.87 0 90 455 0 40 090 mm 6 0 85 400 60 800 000 * At different operating T( C) : R = R0 C {+ α (T C 0)} α : Temperature coefficient at 0 C = 0.009 for copper & 0.0040 for aluminium ** Laying conditions : Underground : Temperature of the soil 0 C Thermal resistivity 00 C cm/w In air : Ambient temperature 0 C *** Greater sizes are also available 8

6/0 () KV THREE CORE, XLPE INSULATED, PVC SHEATHED, SCREENED, UNARMOURED CABLES. Type MN, MA Conforming to IEC 60 DIMENSIONAL CHARACTERISTICS 6 0 85 Radial Thickness of Diameters Approximative net weight Inner Outer Copper cable Aluminium cable Insulation Sheath Sheath Conductor Insulation Overall Conductor Cable Conductor Cable....4.6.7.8.9.. 4.8 6.0 7.5 8. 0.0.8. 4.8 6.55 8.7..6.8 4. 6. 7.8 9.6..6 4. 6.5 9. 6 9 4 45 48 5 56 59 6 69 75 49 679 94 74 84 5 7 960 4969 67 807 4 8 0 4 4400 5 6 7400 900 0 06 86 87 559 776 980 04 9 4 80 580 80 90 60 0 40 90 4790 50 Length on drum mm mm mm mm mm mm mm Kg/Km Kg/Km Kg/Km Kg/Km m ELECTRICAL CHARACTERISTICS mm 6 0 85 DC Resistance at 0 C* Copper Ω/Km.5 0.77 0.54 0.87 0.68 0.9 0.5 0.4 0.099 0.0754 0.060 Alu Ω/Km.9.0 0.868 0.64 0.44 0.0 0. 0.06 0.64 0. 0.00 inductance mh/km 0.405 0.77 0.7 0.40 0. 0.06 0.96 0.87 0.79 0.7 0.64 Current carrying capacity ** Underground capacity Cable Cables in air Cables in duct Copper Alu Copper Alu Copper Alu µf/km Amp Amp Amp Amp Amp Amp 0.58 0 0 90 00 80 0.8 55 55 0 0 00 0.0 90 90 45 60 0.4 75 75 90 45 0.6 75 80 85 0.89 0 5 40 60 85 0.7 90 85 5 0.45 40 445 45 75 0.77 4 65 40 0.47 540 4 590 465 5 0.464 60 485 680 5 590 460 * At different operating T( C) : R = R0 C {+ α (T C 0)} α : Temperature coefficient at 0 C = 0.009 for copper & 0.0040 for aluminium ** Laying conditions : Underground : Temperature of the soil 0 C Thermal resistivity 00 C cm/w In air : Ambient temperature 0 C 9

6/0 () KV THREE CORE, XLPE INSULATED, PVC SHEATHED, SCREENED, DOUBLE STEEL TAPE ARMOURED CABLES. Type MNB, MAB Conforming to IEC 60 DIMENSIONAL CHARACTERISTICS 6 0 85 Radial Thickness of Diameters Approximative net weight Inner Outer Copper cable Aluminium cable Insulation Sheath Sheath Conductor Insulation Overall Conductor Cable Conductor Cable....4.5.5.6.6.7.8.9...4.7.8.9.0...5 4.8 6.0 7.5 8. 0.0.8. 4.8 6.55 8.7..6.8 4. 6. 7.8 9.6..6 4. 6.5 9. 4 44 47 54 58 6 65 69 75 8 49 679 94 74 84 5 7 960 4969 67 807 0 7 90 740 46 56 66 76 9000 000 0 06 86 87 559 776 980 04 9 4 00 80 40 860 60 890 490 4890 55 6600 76 Length on drum mm mm mm mm mm mm mm Kg/Km Kg/Km Kg/Km Kg/Km m ELECTRICAL CHARACTERISTICS mm 6 0 85 DC Resistance at 0 C* Copper Ω/Km.5 0.77 0.54 0.87 0.68 0.9 0.5 0.4 0.099 0.0754 0.060 Alu Ω/Km.9.0 0.868 0.64 0.44 0.0 0. 0.06 0.64 0. 0.00 inductance mh/km 0.445 0.45 0.9 0.74 0. 0.6 0. 0.6 0.07 0. 0.9 Current carrying capacity ** Underground capacity Cable Cables in air Cables in duct Copper Alu Copper Alu Copper Alu µf/km Amp Amp Amp Amp Amp Amp 0.58 0 0 90 00 80 0.8 55 55 0 0 00 0.0 90 90 45 60 0.4 75 75 90 45 0.6 75 80 85 0.89 0 5 40 60 85 0.7 90 85 5 0.45 40 445 45 75 0.77 4 65 40 0.47 540 4 590 465 5 0.464 60 485 680 5 590 460 * At different operating T( C) : R = R0 C {+ α (T C 0)} α : Temperature coefficient at 0 C = 0.009 for copper & 0.0040 for aluminium ** Laying conditions : Underground : Temperature of the soil 0 C Thermal resistivity 00 C cm/w In air : Ambient temperature 0 C 0

8.7/5 (8) KV SINGLE CORE, XLPE INSULATED, PVC SHEATHED, SCREENED, UNARMOURED CABLES. Type M4N, M4A Conforming to IEC 60 DIMENSIONAL CHARACTERISTICS Radial Thickness of Diameters Approximative net weight Inner Outer Copper cable Aluminium cable Insulation Sheath Sheath Conductor Insulation Overall Conductor Cable Conductor Cable Length on drum mm mm mm mm mm mm mm Kg/Km Kg/Km Kg/Km Kg/Km m 0 85 400 60 800 000 ELECTRICAL CHARACTERISTICS.6.7.7.7.8.9.9....4.6.7 6.0 7.5 8. 0.0.8. 4.8 6.55 8.7. 4. 7..0 7. 4.6 6.0 7.5 8. 0.0.8. 4.8 6.55 8.7. 4. 7.5 4.6 47.6 5. 4 6 8 0 6 8 40 44 48 54 59 4 4 608 84 065 07 640 098 646 460 46 56 70 9080 655 780 9 4 7 040 4 0 6 4 55 69 87 0800 68 8 85 6 4 98 499 68 804 05 88 758 565 6 745 885 00 0 0 540 80 090 490 740 4490 DC Resistance at Current carrying capacity ** 0 C* inductance Underground Cables in air Cables in duct Cable Copper Alu Trefoil Flat capacity formation formation Copper Alu Copper Alu Copper Alu Ω/Km Ω/Km mh/km mh/km µf/km Amp Amp Amp Amp Amp Amp 0.77.0 0.447 0.6 0. 60 40 05 0.54 0.868 0.4 0.607 0.66 00 60 0 0.87 0.64 0.40 0.585 0.8 0 80 45 90 05 60 0.68 0.44 0.79 0.564 0.07 80 0 05 5 00 0.9 0.0 0.6 0.546 0. 60 75 90 0 45 0.5 0. 0. 0.56 0.4 85 4 0 5 80 0.4 0.06 0.6 0.5 0.76 40 485 75 40 0 0.099 0.64 0.6 0.5 0. 490 80 560 40 465 65 0.0754 0. 0.9 0.4 0. 560 440 660 555 4 0.060 0.00 0.04 0.489 0.67 640 7 590 640 0.04 0.0778 0.90 0.474 0.40 70 5 8 680 740 580 0.066 0.0605 0.84 0.468 0.466 80 640 000 790 855 6 0.08 0.0469 0.76 0.46 0.5 90 740 90 00 790 0.0 0.067 0.6 0.448 0.609 005 80 90 060 60 900 0.076 0.09 0.8 0.44 0.674 00 90 460 0 40 090 mm 0 85 400 60 800 000 * At different operating T( C) : R = R0 C {+ α (T C 0)} α : Temperature coefficient at 0 C = 0.009 for copper & 0.0040 for aluminium ** Laying conditions : Underground : Temperature of the soil 0 C Thermal resistivity 00 C cm/w In air : Ambient temperature 0 C *** Greater sizes are also available

8.7/5 (8) KV THREE CORE, XLPE INSULATED, PVC SHEATHED, SCREENED, UNARMOURED CABLES. Type M4N, M4A Conforming to IEC 60 DIMENSIONAL CHARACTERISTICS 0 85 Radial Thickness of Diameters Approximative net weight Inner Outer Copper cable Aluminium cable Insulation Sheath Sheath Conductor Insulation Overall Conductor Cable Conductor Cable.4.4.7.8.9.0.. 6.0 7.5 8. 0.0.8. 4.8 6.55 8.7. 6.0 7.5 8. 0.0.8. 4.8 6.55 8.7. 44 47 54 58 6 65 69 75 80 679 94 74 84 5 7 960 4969 67 807 80 060 8 4840 50 66 8000 9800 800 06 86 87 559 776 980 04 9 4 70 90 90 060 4 900 4540 5 600 Length on drum mm mm mm mm mm mm mm Kg/Km Kg/Km Kg/Km Kg/Km m ELECTRICAL CHARACTERISTICS mm 0 85 DC Resistance at 0 C* Copper Ω/Km 0.77 0.54 0.87 0.68 0.9 0.5 0.4 0.099 0.0754 0.060 Alu Ω/Km.0 0.868 0.64 0.44 0.0 0. 0.06 0.64 0. 0.00 inductance mh/km 0.404 0.8 0.64 0.4 0.6 0.4 0.04 0.99 0.87 0.78 Current carrying capacity ** Underground capacity Cable Cables in air Cables in duct Copper Alu Copper Alu Copper Alu µf/km Amp Amp Amp Amp Amp Amp 0. 55 5 60 0 00 0.66 90 45 65 0.8 75 0 75 0.07 0 80 0 85 0. 0 5 45 65 85 0.4 90 05 0 60 0.76 45 0 4 45 75 0. 465 60 40 0. 540 40 600 4 400 0.67 60 490 685 5 585 455 * At different operating T( C) : R = R0 C {+ α (T C 0)} α : Temperature coefficient at 0 C = 0.009 for copper & 0.0040 for aluminium ** Laying conditions : Underground : Temperature of the soil 0 C Thermal resistivity 00 C cm/w In air : Ambient temperature 0 C

8.7/5 (8) KV THREE CORE, XLPE INSULATED, PVC SHEATHED, SCREENED, DOUBLE STEEL TAPE ARMOURED CABLES. Type M4NB, M4AB Conforming to IEC 60 DIMENSIONAL CHARACTERISTICS 0 85 Radial Thickness of Diameters Approximative net weight Inner Outer Copper cable Aluminium cable Insulation Sheath Sheath Conductor Insulation Overall Conductor Cable Conductor Cable.4.4.5.5.6.7.7.8.9.6.7.8.0....5.7 6.0 7.5 8. 0.0.8. 4.8 6.55 8.7. 6.0 7.5 8. 0.0.8. 4.8 6.55 8.7. 5 55 59 6 67 76 8 88 679 94 74 84 5 7 960 4969 67 807 0 690 460 5 6 7 8 9800 0 4800 06 86 87 559 776 980 04 9 4 740 00 860 4490 0 55 6 7 900 Length on drum mm mm mm mm mm mm mm Kg/Km Kg/Km Kg/Km Kg/Km m ELECTRICAL CHARACTERISTICS mm 0 85 DC Resistance at 0 C* Copper Ω/Km 0.77 0.54 0.87 0.68 0.9 0.5 0.4 0.099 0.0754 0.060 Alu Ω/Km.0 0.868 0.64 0.44 0.0 0. 0.06 0.64 0. 0.00 inductance mh/km 0.444 0.40 0.400 0.77 0.8 0.45 0. 0.9 0.6 0.06 Current carrying capacity ** Underground capacity Cable Cables in air Cables in duct Copper Alu Copper Alu Copper Alu µf/km Amp Amp Amp Amp Amp Amp 0. 55 5 60 0 00 0.66 90 45 65 0.8 75 0 75 0.07 0 80 0 85 0. 0 5 45 65 85 0.4 90 05 0 60 0.76 45 0 4 45 75 0. 465 60 40 0. 540 40 600 4 400 0.67 60 490 685 5 585 455 * At different operating T( C) : R = R0 C {+ α (T C 0)} α : Temperature coefficient at 0 C = 0.009 for copper & 0.0040 for aluminium ** Laying conditions : Underground : Temperature of the soil 0 C Thermal resistivity 00 C cm/w In air : Ambient temperature 0 C

/0 (4) KV SINGLE CORE, XLPE INSULATED, PVC SHEATHED, SCREENED, UNARMOURED CABLES. Type M5N, M5A Conforming to IEC 60 DIMENSIONAL CHARACTERISTICS Radial Thickness of Diameters Approximative net weight Inner Outer Copper cable Aluminium cable Insulation Sheath Sheath Conductor Insulation Overall Conductor Cable Conductor Cable Length on drum mm mm mm mm mm mm mm Kg/Km Kg/Km Kg/Km Kg/Km m 0 85 400 60 800 000 ELECTRICAL CHARACTERISTICS mm 0 85 400 60 800 000.7.8.8.9.9....4.6.8 7.5 8. 0.0.8. 4.8 6.55 8.7. 4. 7..0 7. 4.6 9.5 0..8. 6.8 8.55 0.7. 6.5 9.7 44.4.4 55.0 6 8 0 4 8 4 4 46 5 57 6 4 608 84 065 07 640 098 646 460 46 56 70 9080 865 00 590 860 90 90 40 80 4680 50 700 90 8 85 6 4 98 499 68 804 05 88 758 6 7 8 000 0 80 4 680 960 680 80 400 480 DC Resistance at Current carrying capacity ** 0 C* inductance Underground Cables in air Cables in duct Cable Copper Alu Trefoil Flat capacity formation formation Copper Alu Copper Alu Copper Alu Ω/Km Ω/Km mh/km mh/km µf/km Amp Amp Amp Amp Amp Amp 0.54 0.868 0.49 0.6 0.45 00 60 0 0.87 0.64 0.47 0.60 0.59 0 80 45 90 05 60 0.68 0.44 0.94 0.579 0.80 80 0 05 5 00 0.9 0.0 0.75 0.560 0.0 60 75 90 0 45 0.5 0. 0.64 0.549 0.9 85 4 0 5 80 0.4 0.06 0.5 0.59 0.6 40 485 75 40 0 0.099 0.64 0.8 0.5 0.7 490 80 560 40 465 65 0.0754 0. 0.0 0.54 0.8 560 440 660 555 4 0.060 0.00 0.9 0.4 0. 640 7 590 640 0.04 0.0778 0.04 0.489 0.6 70 5 8 680 740 580 0.066 0.0605 0.9 0.477 0.94 80 640 000 790 855 6 0.08 0.0469 0.88 0.47 0.448 90 740 90 00 790 0.0 0.067 0.74 0.459 0.59 00 80 90 060 55 900 0.076 0.09 0.68 0.45 0.57 05 90 460 0 40 090 * At different operating T( C) : R = R0 C {+ α (T C 0)} α : Temperature coefficient at 0 C = 0.009 for copper & 0.0040 for aluminium ** Laying conditions : Underground : Temperature of the soil 0 C Thermal resistivity 00 C cm/w In air : Ambient temperature 0 C *** Greater sizes are also available 4

/0 (4) KV THREE CORE, XLPE INSULATED, PVC SHEATHED, SCREENED, UNARMOURED CABLES. Type M5N, M5A Conforming to IEC 60 DIMENSIONAL CHARACTERISTICS Radial Thickness of Diameters Approximative net weight Inner Outer Copper cable Aluminium cable Insulation Sheath Sheath Conductor Insulation Overall Conductor Cable Conductor Cable 0 85 Length on drum mm mm mm mm mm mm mm Kg/Km Kg/Km Kg/Km Kg/Km m.6.7.8.9.0...6 7.5 8. 0.0.8. 4.8 6.55 8.7. 9.5 0..8. 6.8 8.55 0.7. 5 54 58 6 66 74 79 85 94 74 84 5 7 960 4969 67 807 900 440 4 500 600 700 84 0 0 86 87 559 776 980 04 9 4 960 440 860 440 49 58 6800 ELECTRICAL CHARACTERISTICS mm 0 85 DC Resistance at 0 C* Copper Ω/Km 0.54 0.87 0.68 0.9 0.5 0.4 0.099 0.0754 0.060 Alu Ω/Km 0.868 0.64 0.44 0.0 0. 0.06 0.64 0. 0.00 inductance mh/km 0.40 0.8 0.60 0.4 0.0 0. 0. 0. 0.90 Current carrying capacity ** Underground capacity Cable Cables in air Cables in duct Copper Alu Copper Alu Copper Alu µf/km Amp Amp Amp Amp Amp Amp 0.45 90 45 65 0.59 75 0 75 0.80 0 80 0 85 0.0 0 5 45 65 85 0.9 90 05 0 60 0.6 45 0 4 45 75 0.7 465 60 40 0.8 540 40 600 4 400 0. 60 490 685 5 585 455 * At different operating T( C) : R = R0 C {+ α (T C 0)} α : Temperature coefficient at 0 C = 0.009 for copper & 0.0040 for aluminium ** Laying conditions : Underground : Temperature of the soil 0 C Thermal resistivity 00 C cm/w In air : Ambient temperature 0 C

/0 (4) KV THREE CORE, XLPE INSULATED, PVC SHEATHED, SCREENED, DOUBLE STEEL TAPE ARMOURED CABLES. Type M5NB, M5AB Conforming to IEC 60 DIMENSIONAL CHARACTERISTICS Radial Thickness of Diameters Approximative net weight Inner Outer Copper cable Aluminium cable Insulation Sheath Sheath Conductor Insulation Overall Conductor Cable Conductor Cable 0 85.5.6.6.7.8.8.9. Length on drum mm mm mm mm mm mm mm Kg/Km Kg/Km Kg/Km Kg/Km m.8.9.0....5.7.8 7.5 8. 0.0.8. 4.8 6.55 8.7. 9.5 0..8. 6.8 8.55 0.7. 57 60 64 68 7 76 80 87 9 94 74 84 5 7 960 4969 67 807 4 4780 50 6800 7900 9000 0400 5 86 87 559 776 980 04 9 4 890 4400 0 55 600 6900 87 99 ELECTRICAL CHARACTERISTICS mm 0 85 DC Resistance at 0 C* Copper Ω/Km 0.54 0.87 0.68 0.9 0.5 0.4 0.099 0.0754 0.060 Alu Ω/Km 0.868 0.64 0.44 0.0 0. 0.06 0.64 0. 0.00 inductance mh/km 0.44 0.4 0.96 0.76 0.6 0. 0.4 0.0 0.45 Current carrying capacity ** Underground capacity Cable Cables in air Cables in duct Copper Alu Copper Alu Copper Alu µf/km Amp Amp Amp Amp Amp Amp 0.45 90 45 65 0.59 75 0 75 0.80 0 80 0 85 0.0 0 5 45 65 85 0.9 90 05 0 60 0.6 45 0 4 45 75 0.7 465 60 40 0.8 540 40 600 4 400 0. 60 490 685 5 585 455 * At different operating T( C) : R = R0 C {+ α (T C 0)} α : Temperature coefficient at 0 C = 0.009 for copper & 0.0040 for aluminium ** Laying conditions : Underground : Temperature of the soil 0 C Thermal resistivity 00 C cm/w In air : Ambient temperature 0 C 6

8/0 (6) KV SINGLE CORE, XLPE INSULATED, PVC SHEATHED, SCREENED, UNARMOURED CABLES. Type M6N, M6A Conforming to IEC 60 DIMENSIONAL CHARACTERISTICS Radial Thickness of Diameters Approximative net weight Inner Outer Copper cable Aluminium cable Insulation Sheath Sheath Conductor Insulation Overall Conductor Cable Conductor Cable Length on drum mm mm mm mm mm mm mm Kg/Km Kg/Km Kg/Km Kg/Km m 0 85 400 60 800 000......4.6.7.8.9 8. 0.0.8. 4.8 6.55 8.7. 4. 7..0 7. 4.6 6. 9.8..8 5 6.7 9. 4. 45. 49.4 55.4 60.0 7 8 40 4 44 48 49 5 56 6 67 4 608 84 065 07 640 098 646 460 46 56 70 9080 90 660 990 80 60 00 60 4 5 6 70 9600 0 8 85 6 4 98 499 68 804 05 88 758 090 60 400 540 690 890 760 0 790 4580 5400 ELECTRICAL CHARACTERISTICS mm 0 85 400 60 800 000 DC Resistance at Current carrying capacity ** 0 C* inductance Underground Cables in air Cables in duct Cable Copper Alu Trefoil Flat capacity formation formation Copper Alu Copper Alu Copper Alu Ω/Km Ω/Km mh/km mh/km µf/km Amp Amp Amp Amp Amp Amp 0.87 0.64 0.464 0.649 0.6 0 80 45 90 05 60 0.68 0.44 0.49 0.6 0.5 80 0 05 5 00 0.9 0.0 0.47 0.60 0.66 60 75 90 0 45 0.5 0. 0.98 0.58 0.79 85 4 0 5 80 0.4 0.06 0.87 0.57 0.9 40 485 75 40 0 0.099 0.64 0.75 0.559 0.05 490 80 560 40 465 65 0.0754 0. 0.9 0.544 0. 560 440 660 555 4 0.060 0.00 0. 0.5 0.44 640 7 590 640 0.04 0.0778 0.0 0.55 0.67 70 5 8 680 740 580 0.066 0.0605 0.7 0. 0.9 80 640 000 790 855 6 0.08 0.0469 0.07 0.49 0.6 90 740 90 00 790 0.0 0.067 0.9 0.476 0.75 05 80 90 060 55 900 0.076 0.09 0.84 0.468 0.4 0 9 465 0 40 090 * At different operating T( C) : R = R0 C {+ α (T C 0)} α : Temperature coefficient at 0 C = 0.009 for copper & 0.0040 for aluminium ** Laying conditions : Underground : Temperature of the soil 0 C Thermal resistivity 00 C cm/w In air : Ambient temperature 0 C *** Greater sizes are also available 7

8/0 (6) KV THREE CORE, XLPE INSULATED, PVC SHEATHED, SCREENED, UNARMOURED CABLES. Type M6N, M6A Conforming to IEC 60 DIMENSIONAL CHARACTERISTICS Radial Thickness of Diameters Approximative net weight Inner Outer Copper cable Aluminium cable Insulation Sheath Sheath Conductor Insulation Overall Conductor Cable Conductor Cable 0 85....5.6.8 4.0 8. 0.0.8. 4.8 6.55 8.7. 6. 9.8..8 5 6.7 9. 69 7 77 80 84 88 9 00 74 84 5 7 960 4969 67 807 470 5600 60 76 87 0 0 4400 87 559 776 980 04 9 4 840 40 4900 5400 59 6 7600 88 Length on drum mm mm mm mm mm mm mm Kg/Km Kg/Km Kg/Km Kg/Km m 00 00 00 ELECTRICAL CHARACTERISTICS mm 0 85 DC Resistance at 0 C* Copper Ω/Km 0.87 0.68 0.9 0.5 0.4 0.099 0.0754 0.060 Alu Ω/Km 0.64 0.44 0.0 0. 0.06 0.64 0. 0.00 inductance mh/km 0.4 0.409 0.88 0.7 0.6 0.48 0. 0.4 Current carrying capacity ** Underground capacity Cable Cables in air Cables in duct Copper Alu Copper Alu Copper Alu µf/km Amp Amp Amp Amp Amp Amp 0.6 75 0 75 0.5 0 80 0 85 0.66 0 5 45 65 85 0.79 90 05 0 60 0.9 45 0 4 45 75 0.05 465 60 40 0. 540 40 600 4 400 0.44 60 490 685 5 585 455 * At different operating T( C) : R = R0 C {+ α (T C 0)} α : Temperature coefficient at 0 C = 0.009 for copper & 0.0040 for aluminium ** Laying conditions : Underground : Temperature of the soil 0 C Thermal resistivity 00 C cm/w In air : Ambient temperature 0 C 8

8/0 (6) KV THREE CORE, XLPE INSULATED, PVC SHEATHED, SCREENED, DOUBLE STEEL TAPE ARMOURED CABLES. Type M6NB, M6AB Conforming to IEC 60 DIMENSIONAL CHARACTERISTICS Radial Thickness of Diameters Approximative net weight Inner Outer Copper cable Aluminium cable Insulation Sheath Sheath Conductor Insulation Overall Conductor Cable Conductor Cable 0 85.8.8.9.....5.7.8.9 4. 4. 8. 0.0.8. 4.8 6.55 8.7. 6. 9.8..8 5 6.7 9. 75 79 8 88 9 96 0 08 74 84 5 7 960 4969 67 807 6 74 86 06 800 400 55 800 87 559 776 980 04 9 4 0 600 6900 8400 90 99 00 6 Length on drum mm mm mm mm mm mm mm Kg/Km Kg/Km Kg/Km Kg/Km m 00 00 00 ELECTRICAL CHARACTERISTICS mm 0 85 DC Resistance at 0 C* Copper Ω/Km 0.87 0.68 0.9 0.5 0.4 0.099 0.0754 0.060 Alu Ω/Km 0.64 0.44 0.0 0. 0.06 0.64 0. 0.00 inductance mh/km 0.479 0.4 0.47 0.4 0.97 0.8 0.68 0.7 Current carrying capacity ** Underground capacity Cable Cables in air Cables in duct Copper Alu Copper Alu Copper Alu µf/km Amp Amp Amp Amp Amp Amp 0.6 75 0 75 0.5 0 80 0 85 0.66 0 5 45 65 85 0.79 90 05 0 60 0.9 45 0 4 45 75 0.05 465 60 40 0. 540 40 600 4 400 0.44 60 490 685 5 585 455 * At different operating T( C) : R = R0 C {+ α (T C 0)} α : Temperature coefficient at 0 C = 0.009 for copper & 0.0040 for aluminium ** Laying conditions : Underground : Temperature of the soil 0 C Thermal resistivity 00 C cm/w In air : Ambient temperature 0 C 9

6. /0 (4) KV THREE CORE XLPE INSULATED BUNDLED OVERHEAD CONDUCTORS (TORSADE) OUR TYPES: M5AT M5AT M5A4T. SCOPE This specification covers three core overhead insulated cables, rated /0 (4) KV generally conforming to IEC 60.. CONSTRUCTION. Conductor Aluminium, circular stranded and compacted conforming to IEC 608 Class.. Conductor Screening Extruded thermosetting semiconductor layer, conforming to IEC 60.. Insulation XLPE thermosetting material conforming to IEC 60..4 Insulation Screening.4. Semi conducting screen: Extruded thermosetting semiconducting layer, applied under a swellable semiconducting tape for watertightness..4. Metal screen: Plain soft copper wire and / or copper tape applied helically, or aluminium tape applied longitudinally bonded to the outer PE sheath. Outer sheath Extruded black PE sheath, or PVC upon specific customer requirements, conforming to IEC 60..7 Steel Messenger or mm steel stranded wires, covered with black PE, or PVC upon specific customer requirements.. TESTS All tests required by the IEC 60, either on raw materials or on finished products. 40

/0 (4) KV THREE CORE, XLPE INSULATED, BUNDLED OVERHEAD CONDUCTORS (TORSADE) Type M5A4T Conforming to IEC 60 DIMENSIONAL CHARACTERISTICS mm x / 6 x / 6 x / 6 x0 / 6 x / x85 / x / Radial Thickness of Insulation mm Outer Sheath mm.8.9.9.. Diameters Approximative Suspension Over Over net weight bunched Conductor Strand Jacket Conductors Conductor Cable 8. 0..0 4.6 6. 8.8 8 0 7 40 74 54 74 4 4 460 86 80 00 890 44 4960 56 Length on drum mm mm mm mm Kg/Km Kg/Km m 67 7 75 78 8 85 90 ELECTRICAL CHARACTERISTICS mm 0 85 DC Resistance at 0 C* Alu Ω/Km 0.64 0.44 0.0 0. 0.06 0.64 0. inductance mh/km 0.46 0.405 0.85 0.76 0.6 0. 0.7 capacity µf/km 0.75 0.04 0.7 0. 0.60 0.8 0.4 Current carrying capacity ** Cables in air Amp 76 0 69 0 405 480 * At different operating T( C) : R = R0 C {+ α (T C 0)} α : Temperature coefficient at 0 C = 0.009 for copper & 0.0040 for aluminium ** Laying conditions : Underground : Temperature of the soil 0 C Thermal resistivity 00 C cm/w In air : Ambient temperature 0 C *** Greater sizes are also available 4

7 TECHNICAL INFORMATION 7. Formulae Ohms law Joules law Resistance of a line (feed and return) DC Power Single phase Power Three phase Power DC Current AC Single core current AC Three phase current Efficiency U = RI W = RI t R= L x S P(w) = U I P(w) = U I cos ϕ P(w) = U I cos ϕ P (w) I= U P(VA) I = = U P(VA) I= = e= U P output P input P (W) U cos ϕ U P (W) cos ϕ U I R W t L x S P Cosϕ e u = = = = = = = = = = = = Rated Voltage in V (volts) (between phase in three phase system). Current in A (Amperes). Resistance in (ohms). Energy in Ws (Watt second). Time in s (second) Length of cable in m (meter). Conductivity (56 for copper and 4 for Aluminium). Cross al area in mm. Power in W (Watt) or VA (Volt Ampere). Power factor. Efficiency. Voltage drop sending to receiving end of line in V(Volts). Voltage drop Nature of the current Single phase AC/DC systems Three phase system Voltage drop Size u (v) mm u = L I x S L P(w) u = x S U If current known L I x u If power known L P(w) L P(w) u = S = x S U x u U If current known.7 L I cos ϕ.7 L I cos ϕ u = S = x S x u If power known S = L P(w) S = x u U 4

7. Conversion factors and units Length : The SI unit for length is the m m = 0 cm = 0 mm = 0 Km m = 9.7 in =.8 ft =.096 Yd = 0.64 x 0 miles in = 0.04 m = 0.08 ft = 0.077 Yd = 0.058 x 0 miles ft = 0.048 m = in = 0. Yd = 0.89 x 0 miles Yd = 0.944 m = 6 in = ft = 0.568 x 0 miles mile = 609 m = 660 in = 580 ft = 760 Yd m = meters, in = inches, ft = feet, Yd = Yards Weight : The SI unit for weight is the Kg Kg = 0 g = 0 T (metric ton) Kg =.046 lb =.7 oz oz = 8.49 x 0 Kg = 0.06 lb Kg = Kilogrammes, lb = pounds, oz = ounces Volume : The SI unit for volume is the m m = 0 dm = 0 6 cm = 0 9 mm m = 000 L =. ft = 9.97 I.gal = 64.7 U.S. gal L = 0.00 m = 0.0 ft = 0.997 I.gal = 0.647 U.S. gal ft = 8.7x0 m = 8.7 L = 6.88 I.gal = 7.479 U.S. gal I.gal = 46 x 0 m = 46 L = 0.605 ft =.009 U.S. gal U.S. gal =.7854 x 0 m =.785 L = 0.66 ft = 0.87 I. gal l = liters, ft = feet, I.gal = Imperial gallon, U.S.gal = United States gallon Force : The SI unit for force is the N N = 0.097 Kgf = 0.48 Lbf Kgf = 9.80665 N =.046 Lbf Lbf = 4.448 N = 0.456 Kgf N = Newton, Kgf = Kilogram force, Lbf = pound force Power : The SI unit for power is the W W = 0.0 Kgm / s =.9 x 0 HP = BTU / h Kgm / s = 9.8 W = 0.0 HP = 7 BTU / h HP = 7.5 W = 75 Kgm / s = Btu /h BTu /h = 0.9 W = 0.098 Kgm / s = 0.9 x 0 HP w = watt, Kgm / s = Kilogramme meter per second, HP = metric Horse power, BTU /h = British thermal unit per hour 4

Pressure : The SI unit for pressure is the Pa = N/m N /m = 0 5 Kgf / cm = 0 5 bar Kgf / cm = 0 5 N / m = bar Pa = Pascal, N/m = Newton per square meter Kgf / cm = Kilogramme force per square centimeter Work : The SI unit for work is the J J = Ws (Wattsecond) = Nm (Newton meter) J = 0.778 x 0 6 Kwh = 0.9 x 0 Kcal Kwh =.6 x 0 6 J = 859.8 Kcal Kcal = 486.8 J =.6 x 0 Kwh J = Joules, Kwh = Kilowatt hour, Kcal = Kilocalories Temperature : The SI unit for Temperature is the Kelvin (K) Temperature in o C = Temperature in o K 7 = 5/9 (Temperature in o F ) Temperature in o K = Temperature in o C + 7 o C = degree celcius, o K = degree Kelvin, o F = degree Fahrenheit 44