Coveo Platform 7.0. Hardware and Software Recommendations

Size: px
Start display at page:

Download "Coveo Platform 7.0. Hardware and Software Recommendations"

Transcription

1 Cve Platfrm 7.0 Hardware and Sftware Recmmendatins

2 Ntice The cntent in this dcument represents the current view f Cve as f the date f publicatin. Because Cve cntinually respnds t changing market cnditins, infrmatin in this dcument is subject t change withut ntice. Fr the latest dcumentatin, visit ur website at Cpyright 2013, Cve Slutins Inc. All rights reserved. Cve is a trademark f Cve Slutins Inc. This dcument is prtected by cpyright and ther intellectual prperty law and is subject t the cnfidentiality and ther restrictins specified in the Cve License Agreement. Dcument part number: PM EN Publicatin date: 10/17/2015 ii

3 Table f Cntents 1. Cve Platfrm Hardware and Sftware Requirements iv 1.1 Index f up t 5 Millin Dcuments (Minimum Requirements) iv 1.2 Index Frm 5 t 20 Millin Dcuments iv 1.3 Index Frm 20 t 40 Millin Dcuments v 1.4 Index Frm 40 t 80 Millin Dcuments v 1.5 Operating System Cmpatibility vi 1.6 Index Size vi 1.7 Nn Index Files vii 1.8 RAID Cnfiguratin vii 1.9 Near Real-Time Indexing Disk viii 1.10 Third-Party Sftware Requirement viii 1.11 Relatin Between CES Features and Hardware Resurces viii 1.12 RAID Type Cmparisn and Recmmendatins x 1.13 Virtualized Server Guidelines x Guidelines xi 2. Cve Scalability Mdel xiii 2.1 One Server Cnfiguratins xiii 2.2 Larger Number f Dcuments: Add a Slice xiii 2.3 Mre Queries: Add Mirrr and Frnt-End Servers xiv 2.4 Heavy Dcument Cnversin: Add Remte Cnverter Servers xv 2.5 Indexes in Varius Lcatins: Set Up a Gegraphically Distributed Index (GDI) xv 2.6 Abut Index Slices xvi 2.7 Abut Mirrr Servers xvii 2.8 Abut Gegraphically Distributed Indexing xviii Setting up Gegraphically Distributed Indexing xx Setting up Gegraphically Distributed Indexing Using a Mirrr xx 3. Planning Repsitries t Index xxii iii

4 1. Cve Platfrm Hardware and Sftware Requirements This tpic presents the hardware, sftware, and perating system specs fr the server n which yu install Cve Enterprise Search (CES) fr varius index size ranges that ne Cve instance can manage. The system specificatins apply t back-end Cve Master and Mirrr servers. Ntes: Operate CES n a dedicated server. When ther prcesses are running in parallel r when the query activity reaches peaks and becmes missin-critical, a server meeting the specified requirements may nt be sufficient. Cve prducts wrk best n physical machines, but als supprt virtual envirnments such as VMware (ESX), Micrsft Hyper-V, Amazn Web Services (AWS), Micrsft Azure. Cnsider distributing the index ver mre than ne Cve instance when the number f dcuments t index exceeds the maximum index size presented in this tpic (see Cve Scalability Mdel). Cntact Cve Supprt fr assistance t select the best Cve cnfiguratin fr yur envirnment. 1.1 Index f up t 5 Millin Dcuments (Minimum Requirements) Cmpnent Operating System CPU - Prcessrs RAM - Memry Disk - OS and Prgram Files Disk - Index (1 slice) Disk - Near Real-Time Indexing (ptinal) Minimum Requirement Windws Server 4 Cre (1 4), 2.0 GHz r higher 16 GB 1 x 150 GB SATA 7.2/10 K RPM 1 x 300 GB SATA 7.2/10 K RPM 1 x 150 GB SSD r SATA 7.2/10 K RPM Imprtant: Ensure that yur envirnment meets the abve minimum requirements and fllws recmmendatins belw befre cntacting Cve Supprt t get help fr a perfrmance issue. 1.2 Index Frm 5 t 20 Millin Dcuments Cmpnent Operating System CPU - Prcessrs Recmmendatin Windws Server 8 Cre (1 8), 2.0 GHz r higher iv

5 Cmpnent RAM - Memry Recmmendatin 32 GB Disks - OS and Prgram Files 2 x 150 GB SAS 10/15 K RPM, RAID 1 Disks - Index (1 slice) 2 x 600 GB SAS 10/15 K RPM, RAID 1 Disks - Other CES Files 2 x 300 GB SAS 10/15 K RPM, RAID 1 Disk - Near Real-Time Indexing (ptinal) 2 x 300 GB SSD r SATA 10 K RPM, RAID Index Frm 20 t 40 Millin Dcuments Cmpnent Operating System CPU - Prcessrs RAM - Memry Recmmendatin Windws Server 16 Cre (2 8) t 24 Cre (2 12), 2.4 GHz r higher 64 GB Disks - OS and Prgram Files 2 x 150 GB SAS 10/15 K RPM, RAID 1 Disks - Index (1 slice) 4 x 600 GB SAS 10/15 K RPM, RAID 10 Disks - Other CES Files 2 x 600 GB SAS 10/15 K RPM, RAID 1 Disk - Near Real-Time Indexing (ptinal) 2 x 300 GB SSD r SATA 10 K RPM, RAID Index Frm 40 t 80 Millin Dcuments Cmpnent Operating System CPU - Prcessrs RAM - Memry Recmmendatin Windws Server 24 Cre (2 12) t 32 Cre (4 8), 2.4 GHz r higher 128 GB Disks - OS and Prgram Files 2 x 150 GB SAS 10/15 K RPM, RAID 1 Disks - Index (slice 1) 4 x 600 GB SAS 10/15 K RPM, RAID 10 Disks - Index (slice 2) 4 x 600 GB SAS 10/15 K RPM, RAID 10 Disks - Other CES Files 2 x 600 GB SAS 10/15 K RPM, RAID 1 Disk - Near Real-Time Indexing (ptinal) 2 x 300 GB SSD r SATA 10 K RPM, RAID 1 v

6 1.5 Operating System Cmpatibility The servers n which CES r Cve.NET Frnt-End run must use ne f the fllwing OS: Windws Server 2012 R2 (with IIS 8) x64 CES (Nvember 2013) Cve.NET Frnt-End (Nvember 2013) Windws Server 2012 (with IIS 8) x64 CES (December 2012) Cve.NET Frnt-End (December 2012) Windws Server 2008 R2 (with IIS 7) x64 Windws Server 2008 (with IIS 7) Imprtant: The x64 Windws OS versin is required fr indexes with mre than 500 K dcuments. Ntes: CES can perate n nn-server versins f Windws perating systems. Hwever, fr prductin purpses, Cve nly supprts and recmmends Windws Server perating systems t prevent perfrmance, stability, and scalability issues. Fr evaluatin purpse nly CES can run under: Windws 8.1 Pr r Enterprise (with IIS 8) CES (Nvember 2013) Cve.NET Frnt-End (Nvember 2013) Windws 8 Pr r Enterprise (with IIS 8) CES (December 2012) Cve.NET Frnt-End (December 2012) Windws 7 Prfessinal, Enterprise, r Ultimate (with IIS 7) 1.6 Index Size The index typically ccupies 30% t 50% f the ttal size f the riginal dcuments. Example: Yu index dcuments that ccupy 1 TB in varius repsitries. With yur mix f cntent type, the index size ends up at 42% f the riginal dcuments size (420 GB). The size f the dedicated index hard disk shuld be at least 500 GB. Dedicate a disk r disk set t the index files. Use lcal disks, direct-attached strage (DAS), r strage area netwrk (SAN). Netwrk-attached strage (NAS) as well as server message blck (SMB) and ther files shares are nt supprted. When a secnd index slice is required, yu must install each slice n separate disk sets. RAID 0 and RAID 5 are nt recmmended. Nte: The index autmatically switches t the read-nly mde t prevent errrs when the index disk free space reaches a minimum f 5 GB. vi

7 1.7 Nn Index Files Fr index sizes with mre than 5 millin dcuments, it is recmmended t stre nn index CES files n a dedicated set f disks t separate inputs/utputs fr these files frm thse fr index slices. The nn index files are: Lg files Default slice files Cnverter files Cnnectr files Cache files Cnfiguratin files Certificate stre files Nte: Yu will specify the path fr these files fllwing the CES installatin when yu create the index. 1.8 RAID Cnfiguratin It is recmmended t create a RAID vlume (a single accessible strage area) fr each f the three categries f files: OS and prgram files Index files slice Other Cve Enterprise Search (CES) files One RAID cntrller can be used fr all lgical vlumes as lng as it supprts the number f disks in yur server. vii

8 Example: The fllwing typical Cve server hard disk RAID cnfiguratin fr a M dcument index is made f 8 disks rganized in three RAID vlumes (C:, D:, and E: in this example). 1.9 Near Real-Time Indexing Disk The Near Real-Time Indexing (NRTI) feature allws t make new dcuments searchable significantly faster fr indexes with tw millin dcuments r mre. When yu want t fully take advantage f this feature, because NRTI is I/O intensive, it is recmmended t add a NRTI dedicated disk t yur Cve Master and Mirrr servers that are serving queries and cnfigure NRTI t use the dedicated disk. The recmmended disk specificatins depend n the size f yur index as shwn in the first sub-sectins f this tpic Third-Party Sftware Requirement The CES installer adds the fllwing required sftware elements when nt already installed: Micrsft.NET Framewrk 3.5 SP1 and (side by side) Internet Infrmatin Services (IIS) 8 r 7 Micrsft Chart Cntrls fr Dtnet Framewrk 3.5 SP1 Micrsft Visual C Redistributable Package (x64) Nte: Micrsft Visual C Redistributable Package (x64) is installed thrugh the CES installer, which requires Micrsft Visual C MSXML Relatin Between CES Features and Hardware Resurces CES invlves several prcesses that are running cncurrently n ne r mre servers. Depending n the size f yur Cve installatin, the activated features, and the phases f peratin, these prcesses cnsume varius viii

9 levels f hardware resurces. The fllwing list describes Cve prcesses, cmpnents, r features that affect the hardware resurces. CPU Dcument cnversin is entirely dne in parallel. The greater number f CPU cres the better. Querying requires several CPU cres t perfrm as many steps in parallel. Queries with numerus terms, exact match peratrs, NEAR peratr, r wildcard characters can take significant amunt f CPU resurces. Nte: Yu can cnfigure the relative pririty f the main, indexing, and crawling prcesses as well as specify the number f query threads. Physical memry (RAM) Indexing uses a lt f physical memry t pre-cmpute mappings frm terms t identifiers. Mre memry is better. Querying requires a gd amunt f physical memry fr caches. Dcument cnversin typically lads dcuments in physical memry. Numerus numerical fields ften require t be kept in physical memry t achieve gd query perfrmance. Facet fields require an amunt f physical memry directly prprtinal t the number f facet values t be cached. Nt having enugh memry t cache facets is nt an ptin, as query perfrmance wuld degrade significantly. String r numerical srting fields have t be set up t be laded in physical memry. Fr string srting fields, the number f field items (cardinality) is what dictates hw much memry is needed, the higher it is, the mre memry it takes. Fr numerical srting fields, cardinality desn t matter, nly the number f dcuments in the index des. Hard disk Indexing is disk I/O intensive. Upgrading the disk subsystem has the mst impact fr better perfrmance. Querying is a prcess requiring a fast disk subsystem. Adding many string fields affects the disk subsystem, because it adds a lt f new terms t the index. Facet fields are easier t index when the number f different facet values is lw (cardinality). The higher the cardinality, the higher the stress n the disk subsystem. String srting fields put mre stress n the disk subsystem than numerical fields. Dcument summarizatin prduces a cncept list and summary sentences that are added t the index. Dcument cnversin accesses hard disk nly fr very large dcuments. ix

10 1.12 RAID Type Cmparisn and Recmmendatins A redundant array f independent disks (RAID) is a technlgy that can be used t prvide increased strage functins and reliability thrugh redundancy. The fllwing table prvides a brief descriptin f the cmmn available RAID types and usage recmmendatin fr CES. Type Brief descriptin Recmmendatin RAID 0 RAID 1 Data striping withut redundancy. Single disk failure destrys the array. High perfrmance. Mirrring. Prvides better read perfrmance than a single disk. Is fault tlerant. Nt recmmended since it is nt fault tlerant Recmmended fr a single slice RAID 10 Hybrid (r nested) RAID that is a stripe f mirrrs (a RAID 0 f RAID 1). Perfrmance is high fr reads and writes. Is fault tlerant, as lng as a mirrr des nt lse all its disks. Recmmended fr tw index slices RAID 0+1 RAID 5 RAID 1 n Offers a slightly better perfrmance but is slightly less fault tlerant than RAID 10. Data striping with blck level parity. Requires all drives but ne t perate. Drive failure requires replacement. Read perfrmance is adequate, but write perfrmance is t lw t be used in an indexing cntext. A set f mirrrs, ne fr each slice, when tw slices are needed. Write and read perfrmances are better because f the way CES evenly splits I/O peratins between the RAID arrays. Basically, CES des the ladbalancing instead f the cntrller. Mre cmplex cnfiguratin. Recmmended Nt recmmended Recmmended t achieve better perfrmances with the same number f drives 1.13 Virtualized Server Guidelines Cve prducts can perate n virtual machines as they d n real hardware. As fr real hardware, the key t a successful Cve deplyment n virtualized hardware is t respect the Cve Platfrm requirements fr the size f yur index (see "Cve Platfrm Hardware and Sftware Requirements" n page iv). Virtualized envirnments can vary greatly frm ne implementatin t anther s it is nt apprpriate t state specific virtual hardware requirements. The nature f virtualized envirnments t ptimize the usage f real hardware resurces by sharing them amng several virtual servers ges against the ideal setup where required resurces are dedicated t a server. Like many prcesses, Cve prcesses such as indexing dcuments r serving queries have varying server resurce lads ver time (see "Relatin Between CES Features and Hardware Resurces" n page viii). x

11 Yu r sme f yur clleagues are experts n yur hypervisr and virtual envirnment. Yu have the respnsibility t ensure that yur Cve virtual server implementatin maximizes the chances that required resurces will be available when they are needed Guidelines Dedicate a virtual machine (VM) respecting the Cve Platfrm requirements fr yur index size fr each Cve server (see "Cve Platfrm Hardware and Sftware Requirements" n page iv). Minimize vercmmitment f CPU and memry resurces n a hst where a virtual Cve server is running. Fr large indexes, when yur virtual envirnments des nt allw yu t create a virtual server that respects the requirements (see "Index Frm 40 t 80 Millin Dcuments " n page v), cnsider the fllwing ptins: Use gegraphically distributed indexing (GDI) t split the index in tw f mre CES instances, each n its dedicated virtual server (see "Abut Gegraphically Distributed Indexing" n page xviii). Cmmissin a dedicated hardware Cve server meeting the requirements. Disk management Many Cve prcesses are disk I/O intensive. The Cve server requirements specify using separate dedicated disks fr specific Cve server prcess categries (perating system and prgrams, index, ther Cve files, and near-real time indexing) t ptimize disk I/O perfrmances and minimize interferences. In a virtual envirnment, the pl f available strage resurces are nt nly shared amng varius prcesses f ne server, but als with prcesses frm several ther servers. Perfrmance issues with virtual Cve servers are ften linked t pr disk perfrmances. Example: The Cve server VM shares a disk resurce with ther hst VMs, including a VM n which a large repsitry is hsted. The disk resurce is able t respnd t the average traffic. Hwever, when the Cve server indexes the large repsitry, the disk resurce thrughput quickly reaches its limit because bth the Cve and the repsitry servers make significantly mre disk I/Os, respectively t index the cntent, and t respnd t the Cve crawler. The perfrmance f bth systems (and any ther hst VMs sharing the same disk resurce) drps significantly while indexing takes place. Yu are the expert with yur hypervisr and virtual envirnment: Avid sharing the same strage resurces between a Cve server and a repsitry that is indexed by Cve. Preferably use disk resurces frm a lw latency strage area netwrk SAN. Attach available virtual disk resurces (such as lgical unit number [LUN] strage) that best match the requirements fr yur index size. Distribute Cve intensive prcess schedules in time when shared resurces are mst available. When yu index mre than ne repsitry, avid starting all surce refreshes at the same time. Define surce schedules that distribute surce refreshes in time during ff-peak hurs. xi

12 Example: The default Every day surce schedule starts every day at midnight. If all yur daily refreshed surces use this schedule, they all start at midnight, ptentially verlading yur shared resurces. Rather create surce specific (like Repsitry1 daily, Repsitry2 daily,...) r time specific (like Daily at 2:00 AM, Weekdays at 3:00 AM, Saturdays at 9:00 PM...) surce schedules that yu can assign t yur surces t distribute the prcesses ver the ff-peak perid. Avid scheduling Cve intensive prcesses at the same time as ther intensive prcesses (such as backups) frm ther systems. xii

13 2. Cve Scalability Mdel The Cve Platfrm implementatin can be easily scaled t serve the search needs fr varius enterprise sizes, frm a single department t a large glbal internatinal rganizatin. The Cve scalability mdel allws t perate either with a single Cve server, with ne Cve instance cmpsed f tw r mre Cve servers, r with tw r mre inter-cnnected Cve instances. Nte: Additinal licensing is required fr Cve instances cnfigured with mre than ne server. 2.1 One Server Cnfiguratins In its simplest frm, a Cve instance is entirely hsted n ne server that perfrms all the prcesses (crawling repsitries, cnverting dcuments, hsting the index, hsting the search interface website, handling query requests, and returning query results). Cve Master server The default slice is always included in the Master server 2.2 Larger Number f Dcuments: Add a Slice When the number f dcuments t index increases, hsting the index n a single hard disk leads t size and perfrmance limitatins. On ne Cve server, the index can be divided in up t tw slices, each n a separate disk (see "Abut Index Slices" n page xvi). Cve Master server xiii

14 The default slice is always included in the Master server Extra slice When the index size exceeds the capacity f ne server, yu can create ther Cve instances and federate search results (see "Abut Gegraphically Distributed Indexing" n page xviii). 2.3 Mre Queries: Add Mirrr and Frnt-End Servers When ne Cve server handles all the CES prcesses and the rate f queries increases, the users may eventually feel that the system is slwer, typically when the results are n lnger returned within a secnd. Adding ne r mre Cve Mirrr servers allws supprting significantly mre queries while maintaining sub-secnd respnse time 90 % f the time. A Mirrr server hlds a cpy f the master index and cntinuusly receives updates frm the Master server (see "Abut Mirrr Servers" n page xvii). When IIS n the Master server is verladed and cannt adequately serve search interfaces, ne r mre Cve Frnt-End servers can als be added t distribute the website hsting f search interfaces and the handling f search queries. The Master server and the Mirrr servers are typically set up in a netwrk lad-balancing (NLB) cnfiguratin t prvide ptimized service availability and failver capability. Fr the same reasns, Frnt-End servers can als be set up in a separate NLB cluster. xiv

15 Tw Cve Frnt-End servers in a netwrk lad-balanced cluster The Cve Master server with tw Mirrr servers in anther netwrk lad-balanced cluster Cve Master server with up t tw slices First Cve Mirrr server with cpies f the Master server slices Secnd Cve Mirrr server with cpies f the Master server slices 2.4 Heavy Dcument Cnversin: Add Remte Cnverter Servers When dcument cnversin requires significant server resurces, the dcument cnversin prcess can be distributed t ne r mre Cve Remte Cnverter servers t free the Cve Master server frm this task. This is useful fr example when cnverting numerus dcuments invlving the CPU and physical memry intensive ptical character recgnitin (OCR) mdule. Cve Master server First Cve Remte Cnverter server fr nrmal dcuments Secnd Cve Remte Cnverter server fr OCR cnversin 2.5 Indexes in Varius Lcatins: Set Up a Gegraphically Distributed Index (GDI) Within an rganizatin, separate Cve instances may be distributed in different departments, buildings, cities, r even cntinents. Multiple Cve instances can be set up t frm a gegraphically distributed index (GDI). Queries entered in a search interface f ne Cve instance returns results gathered and ranked frm tw r mre Cve instances (see "Abut Gegraphically Distributed Indexing" n page xviii). xv

16 Five server Cve instance f department A in the American ffices Three server Cve instance fr department B in the American ffices Single server Cve instance fr the Eurpe ffices 2.6 Abut Index Slices An index slice is a separate physical strage lcatin fr a part f the master index. The purpse f a slice is t distribute the master index cntent t increase the available space and t speed up the indexing prcess. The Master server is always created with ne slice named default. Adding a slice is necessary when the size f the disk limits the number f dcuments that can be indexed r when its perfrmance affects the query respnse time. A slice must be added n separate disks n the Maser server. Nte: When all slices n yur Master server are getting full, cnsider federating search n tw r mre Cve instances (see "Abut Gegraphically Distributed Indexing" n page xviii). Index slices facts A slice can typically cntain up t 40 millin dcuments. One Cve server can typically hst up t tw slices and cntain up t 80 millin dcuments. These numbers can hwever vary depending n a number f factrs. Each slice shuld be created n a separate dedicated disk set. Slice files can als be hsted n a strage area netwrk (SAN). Slices are filled in a distributed fashin s they grw with the same number f dcuments. xvi

17 Nte: When yu add ne slice, because the default slice is getting clse t the limit, new dcuments will be added nly t the new slice until it reaches the number f dcuments cntained in the default slice. The dcuments are then distributed evenly in the tw slices. 2.7 Abut Mirrr Servers A Cve Mirrr server hsts a cpy f the master index lcated n the Cve Master server. A Mirrr server allws distributing queries between servers t speed up the querying prcess and t prvide failver capability. The prcess t add a Mirrr server t a Cve instance invlves the fllwing steps: 1. Installing the Cve Mirrr cmpnents n a dedicated server. 2. Cnfigure the Cve Master server t recgnize and synchrnize its index with remte Mirrr server. 3. Cnfiguring ne r mre Frnt-End servers t send queries t the new mirrr server and t ther available Back-End servers. Mirrr server facts The Cve Master server hsts the master index. In the Administratin Tl, the Master index is named the Default mirrr. A Mirrr server cntains a cpy f the master index, and therefre als duplicates the slice cnfiguratin f the Master server. A Master server sends index changes t the Mirrr servers fllwing its update schedules. The Cve administratr can als schedule Mirrr server updates, fr example t ff-peak hurs. One Mirrr server exclusively serving queries can typically respnd t 25 queries per secnd (QPS), which can be adequate fr several thusand cncurrent users. Mirrr servers prvide a failver capability when the Master server and ne r mre Mirrrs are cnfigured in a netwrk lad-balancing (NLB) cluster. As lng as ne server is up and running, the system can return results t respnd t incming queries. Yu cnsider adding ne r mre Mirrr servers: When the query respnses time increases ntably (abve ne secnd) during peak usage because the Master server is busy with the multiple Cve prcesses. When yu want t have query serving failver capability. When yu want t cmpletely free the Master server frm the query serving task. Tip: Yu can add tw r mre Mirrr servers in an NLB cluster, excluding the master server frm the cluster, and sending all queries frm the Frnt-End servers t the NLB cluster address. xvii

18 A netwrk lad-balanced (NLB) cluster including the Master server and tw Mirrr servers. The Cve Master server Up t tw index slices f the Master server A first Cve Mirrr server with its duplicate Master server index slices A secnd Cve Mirrr server with its duplicate Master server index slices 2.8 Abut Gegraphically Distributed Indexing Gegraphically Distributed Indexing (GDI) is a federated search feature which enables the cmmunicatin between different Cve instances. Its purpse is t deliver high search perfrmance and availability, cnnecting unified indexes frm ffices distributed in different departments, sites, cities, r even cuntries arund the wrld. With GDI, a user makes a single query request in the search interface f the lcal Cve instance. The query is distributed t the remte indexes participating in the federatin. The lcal Cve instance receives, merges, and ranks results frm lcal and remte indexes befre returning them t the user. The Cve scalability mdel supprts tw GDI cnfiguratins that are transparent t end-users. Query federated t the remte index In this cnfiguratin, the lcal Cve instance sends federated queries t the remte indexes ver the WAN (see "Setting up Gegraphically Distributed Indexing" n page xx). xviii

19 This cnfiguratin is very simple t set up and has negligible impact n the WAN bandwidth. The query perfrmance may hwever be affected by the time required fr the rund trip t the remte Cve instance. Example: Users wrking in the Pal Alt and Chicag ffices must be able t search cntent frm the Cve instance in the ther ffice. In the Pal Alt ffice, yu cnfigure the Cve instance t accept queries frm the Cve instance in the Chicag ffice. In the Chicag ffice, yu cnfigure the Cve instance t accept queries frm the Cve instance in the Pal Alt ffice. Query federated t a lcal mirrr f a remte index In this cnfiguratin, yu lcally install a Cve Mirrr server f the remte index. Yu cnfigure the remte Cve instance t synchrnize its index with this Mirrr server ver the WAN. The lcal Cve instance sends federated queries t the lcal mirrr f the remte index (see "Setting up Gegraphically Distributed Indexing Using a Mirrr" n page xx). Example: In the Pal Alt ffice, yu deply a Cve Mirrr server f the Chicag index ffice. Yu cnfigure the Chicag Cve instance t synchrnize its index with the Pal Alt mirrr server. Yu cnfigure the Pal Alt Cve instance t use the mirrr server as the Chicag remte index. In the Chicag ffice, yu can d the same thing fr the Pal Alt ffice. xix

20 2.8.1 Setting up Gegraphically Distributed Indexing Yu can easily create a ne way intercnnectin between a lcal and a remte Cve instance t create a gegraphically distributed index (GDI) using the CES remte index features (see "Abut Gegraphically Distributed Indexing" n page xviii). The cnfiguratin cnsists in enabling the remte Cve instance t accept remte queries, add the remte index t the lcal Cve instance, and cnfigure a lcal search interface t include results frm the remte index. Users frm the lcal Cve instance can then search cntent in the remte index. Nte: Yu can create a tw-way intercnnectin between Cve instances by repeating the fllwing prcedure fr the ther directin. T set up a gegraphically distributed index 1. Ensure that the Cve instances that yu want t intercnnect meet the fllwing requirements: All Cve instances f the gegraphically distributed indexing setup must reside n the same dmain. The CES search applicatin pl fr the lcal Cve instance must run under a dmain accunt. It is a best practice t create a dedicated accunt fr this purpse with a strng passwrd that never changes. 2. On the Cve Master server f the lcal Cve instance: a. Add the remte index. b. Cnfigure a scpe that includes the remte index. 3. On the Cve Frnt-End server f the lcal Cve instance, assign the scpe that includes the remte index t the desired.net search interface. 4. Using the.net search interface fr which yu mdified the scpe, perfrm queries t validate that cntent frm the remte index is returned. Tip: If needed, n the Cve Master server f the remte Cve instance, pen the CES Cnsle t validate that the remte index receives the queries sent frm the lcal.net search interface Setting up Gegraphically Distributed Indexing Using a Mirrr Yu can set up gegraphically distributed indexing using a lcal mirrr f a remte index (see "Abut Gegraphically Distributed Indexing" n page xviii). Nte: Yu can create a tw-way intercnnectin between Cve instances by repeating the fllwing prcedure fr the ther directin. T set up a gegraphically distributed index using a mirrr 1. Ensure that the Cve instances that yu want t intercnnect meet the fllwing requirements: All Cve instances f the gegraphically distributed indexing setup must reside n the same dmain. The CES search applicatin pl fr the lcal Cve instance must run under a dmain accunt. It is a xx

21 best practice t create a dedicated accunt fr this purpse with a strng passwrd that never changes. 2. Physically install a lcal server and install the Cve Mirrr sftware cmpnents withut the web interfaces. 3. Fr the remte Cve instance, cnfigure the Master server t recgnize and synchrnize its index with yur new lcal Mirrr server. 4. On the Cve Master server f the lcal Cve instance: a. Add the remte index. b. Cnfigure a scpe that includes the remte index. 5. On the Cve Frnt-End server f the lcal Cve instance, assign the scpe that includes the remte index t the desired.net search interface. 6. Using the.net search interface fr which yu mdified the scpe, perfrm queries t validate that cntent frm the remte index is returned. Tip: If needed, n the Cve Master server f the remte Cve instance, pen the CES Cnsle t validate that the remte index receives the queries sent frm the lcal.net search interface. xxi

22 3. Planning Repsitries t Index Bringing structured and unstructured data frm multiple repsitries in ne unified index is the great benefit f the Cve Platfrm. When a unified index is available, the Cve slutins allw yu t search, cnslidate, crrelate, and analyze infrmatin frm s, knwledge based dcuments, custmer relatin management (CRM) system, database entries, peple infrmatin, etc. One f the basic tasks when planning a Cve installatin is t identify all the repsitries that yu want t index within yur rganizatin. Cve Enterprise Search (CES) can index many types f repsitries and supprts many specific systems. Analyze the cntent f each repsitry: Estimate the number f dcuments in the repsitry. Estimate the ttal size f the riginal dcuments List the main types f repsitry dcuments. Example: Micrsft Office, PDF, text, html, , database recrds Identify if sme cntent requires special cnversin tls. Example: Text extractin using ptical character recgnitin (OCR) in images. Fr repsitries and desktps, estimate the number f users. Estimate the yearly grwth fr: Number f dcuments Number f users Nte the values fr each repsitry in a table similar t the fllwing ne and cntact the Cve Supprt t help yu plan yur Cve installatin. Repsitry Dcuments Users Type Example Number Ttal size (MB) Annual grwth (%) Number Annual grwth (%) Web pages File share Micrsft Exchange Ltus Ntes Enterprise Vault Website Extranet Netwrk drives xxii

23 Repsitry Dcuments Users Type Example Number Ttal size (MB) Annual grwth (%) Number Annual grwth (%) Lcal files Peple infrmatin Database CMS CRM Wiki Desktps Laptps Micrsft Active Directry Micrsft SQL Server Micrsft SharePint Sitecre Salesfrce Cnfluence xxiii

24 xxiv

SBClient and Microsoft Windows Terminal Server (Including Citrix Server)

SBClient and Microsoft Windows Terminal Server (Including Citrix Server) SBClient and Micrsft Windws Terminal Server (Including Citrix Server) Cntents 1. Intrductin 2. SBClient Cmpatibility Infrmatin 3. SBClient Terminal Server Installatin Instructins 4. Reslving Perfrmance

More information

Licensing Windows Server 2012 for use with virtualization technologies

Licensing Windows Server 2012 for use with virtualization technologies Vlume Licensing brief Licensing Windws Server 2012 fr use with virtualizatin technlgies (VMware ESX/ESXi, Micrsft System Center 2012 Virtual Machine Manager, and Parallels Virtuzz) Table f Cntents This

More information

Licensing Windows Server 2012 R2 for use with virtualization technologies

Licensing Windows Server 2012 R2 for use with virtualization technologies Vlume Licensing brief Licensing Windws Server 2012 R2 fr use with virtualizatin technlgies (VMware ESX/ESXi, Micrsft System Center 2012 R2 Virtual Machine Manager, and Parallels Virtuzz) Table f Cntents

More information

Ten Steps for an Easy Install of the eg Enterprise Suite

Ten Steps for an Easy Install of the eg Enterprise Suite Ten Steps fr an Easy Install f the eg Enterprise Suite (Acquire, Evaluate, and be mre Efficient!) Step 1: Dwnlad the eg Sftware; verify hardware and perating system pre-requisites Step 2: Obtain a valid

More information

1)What hardware is available for installing/configuring MOSS 2010?

1)What hardware is available for installing/configuring MOSS 2010? 1)What hardware is available fr installing/cnfiguring MOSS 2010? 2 Web Frnt End Servers HP Prliant DL 380 G7 2 quad cre Intel Xen Prcessr E5620, 2.4 Ghz, Memry 12 GB, 2 HP 146 GB drives RAID 5 2 Applicatin

More information

How To Install An Orin Failver Engine On A Network With A Network Card (Orin) On A 2Gigbook (Orion) On An Ipad (Orina) Orin (Ornet) Ornet (Orn

How To Install An Orin Failver Engine On A Network With A Network Card (Orin) On A 2Gigbook (Orion) On An Ipad (Orina) Orin (Ornet) Ornet (Orn SlarWinds Technical Reference Preparing an Orin Failver Engine Installatin Intrductin t the Orin Failver Engine... 1 General... 1 Netwrk Architecture Optins and... 3 Server Architecture Optins and... 4

More information

Instant Chime for IBM Sametime Quick Start Guide

Instant Chime for IBM Sametime Quick Start Guide Instant Chime fr IBM Sametime Quick Start Guide Fall 2014 Cpyright 2014 Instant Technlgies. All rights reserved. Cpyright and Disclaimer This dcument, as well as the sftware described in it, is furnished

More information

AccessData Corporation AD Lab System Specification Guide v1.1

AccessData Corporation AD Lab System Specification Guide v1.1 AccessData Crpratin AD Lab System Specificatin Guide v1.1 The AD Lab system specificatin guide was created t ensure the apprpriate is in place supprt an enterprise deplyment f AccessData Lab. The AccessData

More information

Improved Data Center Power Consumption and Streamlining Management in Windows Server 2008 R2 with SP1

Improved Data Center Power Consumption and Streamlining Management in Windows Server 2008 R2 with SP1 Imprved Data Center Pwer Cnsumptin and Streamlining Management in Windws Server 2008 R2 with SP1 Disclaimer The infrmatin cntained in this dcument represents the current view f Micrsft Crpratin n the issues

More information

SMART Active Directory Migrator 9.0.2. Requirements

SMART Active Directory Migrator 9.0.2. Requirements SMART Active Directry Migratr 9.0.2 January 2016 Table f Cntents... 3 SMART Active Directry Migratr Basic Installatin... 3 Wrkstatin and Member Server System... 5 Netwrking... 5 SSL Certificate... 6 Service

More information

Serv-U Distributed Architecture Guide

Serv-U Distributed Architecture Guide Serv-U Distributed Architecture Guide Hrizntal Scaling and Applicatin Tiering fr High Availability, Security, and Perfrmance Serv-U Distributed Architecture Guide v15.1.2.0 Page 1 f 20 Intrductin Serv-U

More information

Installation Guide Marshal Reporting Console

Installation Guide Marshal Reporting Console Installatin Guide Installatin Guide Marshal Reprting Cnsle Cntents Intrductin 2 Supprted Installatin Types 2 Hardware Prerequisites 2 Sftware Prerequisites 3 Installatin Prcedures 3 Appendix: Enabling

More information

Helpdesk Support Tickets & Knowledgebase

Helpdesk Support Tickets & Knowledgebase Helpdesk Supprt Tickets & Knwledgebase User Guide Versin 1.0 Website: http://www.mag-extensin.cm Supprt: http://www.mag-extensin.cm/supprt Please read this user guide carefully, it will help yu eliminate

More information

MaaS360 Cloud Extender

MaaS360 Cloud Extender MaaS360 Clud Extender Installatin Guide Cpyright 2012 Fiberlink Cmmunicatins Crpratin. All rights reserved. Infrmatin in this dcument is subject t change withut ntice. The sftware described in this dcument

More information

State of Wisconsin. File Server Service Service Offering Definition

State of Wisconsin. File Server Service Service Offering Definition State f Wiscnsin File Server Service Service Offering Definitin Dcument Revisin Histry Date Versin Creatr Ntes 2/16/2008 1.0 JD Urfer First pass 2/16/2008 2.0 Tm Runge Editing changes 2/19/2009 2.1 Tm

More information

Caching Software Performance Test: Microsoft SQL Server Acceleration with FlashSoft Software 3.8 for Windows Server

Caching Software Performance Test: Microsoft SQL Server Acceleration with FlashSoft Software 3.8 for Windows Server The linked image cannt be displayed. The file may have been mved, renamed, r deleted. Verify that the link pints t the crrect file and lcatin. Technical Brief Caching Sftware Perfrmance Test: Micrsft SQL

More information

Implementing ifolder Server in the DMZ with ifolder Data inside the Firewall

Implementing ifolder Server in the DMZ with ifolder Data inside the Firewall Implementing iflder Server in the DMZ with iflder Data inside the Firewall Nvell Cl Slutins AppNte www.nvell.cm/clslutins JULY 2004 OBJECTIVES The bjectives f this dcumentatin are as fllws: T cnfigure

More information

Restricted Document. Pulsant Technical Specification

Restricted Document. Pulsant Technical Specification Pulsant Technical Specificatin Title Pulsant Dedicated Server Department Prduct Develpment Cntributrs RR Classificatin Restricted Versin 1.0 Overview Pulsant ffer a Dedicated Server service t underpin

More information

Avatier Identity Management Suite

Avatier Identity Management Suite Avatier Identity Management Suite AIMS Versin 9 System Requirements Versin 9 2603 Camin Ramn Suite 110 San Ramn, CA 94583 Phne: 800-609-8610 925-217-5170 FAX: 925-217-0853 Email: supprt@avatier.cm Page

More information

Introduction to Mindjet MindManager Server

Introduction to Mindjet MindManager Server Intrductin t Mindjet MindManager Server Mindjet Crpratin Tll Free: 877-Mindjet 1160 Battery Street East San Francisc CA 94111 USA Phne: 415-229-4200 Fax: 415-229-4201 mindjet.cm 2013 Mindjet. All Rights

More information

Microsoft Exchange 2010 on VMware Design and Sizing Examples

Microsoft Exchange 2010 on VMware Design and Sizing Examples Micrsft Exchange 2010 n VMware Micrsft Exchange 2010 n VMware This prduct is prtected by U.S. and internatinal cpyright and intellectual prperty laws. This prduct is cvered by ne r mre patents listed at

More information

Serv-U Distributed Architecture Guide

Serv-U Distributed Architecture Guide Serv-U Distributed Architecture Guide Hrizntal Scaling and Applicatin Tiering fr High Availability, Security, and Perfrmance Serv-U Distributed Architecture Guide v14.0.1.0 Page 1 f 16 Intrductin Serv-U

More information

Deployment Overview (Installation):

Deployment Overview (Installation): Cntents Deplyment Overview (Installatin):... 2 Installing Minr Updates:... 2 Dwnlading the installatin and latest update files:... 2 Installing the sftware:... 3 Uninstalling the sftware:... 3 Lgging int

More information

xdb Configuration Guide

xdb Configuration Guide Sitecre 7.5 xdb Cnfiguratin Guide Rev: 9 April 2015 Sitecre 7.5 xdb Cnfiguratin Guide Cnfiguratin guide fr Sitecre administratrs and develpers Sitecre 7.5 Table f Cntents Chapter 1 Intrductin... 3 1.1

More information

This guide is intended for administrators, who want to install, configure, and manage SAP Lumira, server for BI Platform

This guide is intended for administrators, who want to install, configure, and manage SAP Lumira, server for BI Platform Hw T install SAP Lumira, server n SAP BusinessObjects BI platfrm Distributed Install Applies t: SAP Lumira, server versin fr the SAP BusinessObjects BI platfrm Summary This guide is intended fr administratrs,

More information

URM 11g Implementation Tips, Tricks & Gotchas ALAN MACKENTHUN FISHBOWL SOLUTIONS, INC.

URM 11g Implementation Tips, Tricks & Gotchas ALAN MACKENTHUN FISHBOWL SOLUTIONS, INC. URM 11g Implementatin Tips, Tricks & Gtchas ALAN MACKENTHUN FISHBOWL SOLUTIONS, INC. i Fishbwl Slutins Ntice The infrmatin cntained in this dcument represents the current view f Fishbwl Slutins, Inc. n

More information

Disk Redundancy (RAID)

Disk Redundancy (RAID) A Primer fr Business Dvana s Primers fr Business series are a set f shrt papers r guides intended fr business decisin makers, wh feel they are being bmbarded with terms and want t understand a cmplex tpic.

More information

The Relativity Appliance Installation Guide

The Relativity Appliance Installation Guide The Relativity Appliance Installatin Guide February 4, 2016 - Versin 9 & 9.1 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

More information

Using Sentry-go Enterprise/ASPX for Sentry-go Quick & Plus! monitors

Using Sentry-go Enterprise/ASPX for Sentry-go Quick & Plus! monitors Using Sentry-g Enterprise/ASPX fr Sentry-g Quick & Plus! mnitrs 3Ds (UK) Limited, February, 2014 http://www.sentry-g.cm Be Practive, Nt Reactive! Intrductin Sentry-g Enterprise Reprting is a self-cntained

More information

An Oracle White Paper January 2014. Oracle WebLogic Server on Oracle Database Appliance

An Oracle White Paper January 2014. Oracle WebLogic Server on Oracle Database Appliance An Oracle White Paper January 2014 Oracle WebLgic Server n Oracle Database Appliance Intrductin This white paper describes the architecture and highlights the value prpsitin f Oracle WebLgic Server n Oracle

More information

Learn More Cloud Extender Requirements Cheat Sheet

Learn More Cloud Extender Requirements Cheat Sheet MaaS360.cm > Learn Mre Learn Mre Clud Extender Requirements Cheat Sheet OVERVIEW This dcument defines all requirements t ensure a successfully installatin f the Clud Extender t enable use f ActiveSync

More information

E2E Express 3.0. Requirements

E2E Express 3.0. Requirements E2E Express 3.0 Requirements February 2016 Table f Cntents Requirements... 3 Hardware Prerequisites... 3 General Installatin Requirements... 3 Netwrk Requirement... 4 SQL Server Installatin Requirements...

More information

Level 1 Technical. RealPresence Web Suite and Web Suite Pro. Contents

Level 1 Technical. RealPresence Web Suite and Web Suite Pro. Contents Level 1 Technical RealPresence Web Suite and Web Suite Pr Cntents 1 - Glssary... 2 2 Features... 3 RealPresence Platfrm integratin... 3 RealPresence Web Suite Sftware... 3 Sftware Keys... 3 3 - Web Client

More information

Release Notes. Dell SonicWALL Email Security 7.4.3 firmware is supported on the following appliances: Dell SonicWALL Email Security 200

Release Notes. Dell SonicWALL Email Security 7.4.3 firmware is supported on the following appliances: Dell SonicWALL Email Security 200 Release Ntes Email Security Dell SnicWALL Email Security 7.4.3 SnicOS Cntents System Cmpatibility... 1 Enhancements in Email Security 7.4.3... 2 Knwn Issues... 3 Upgrading t Email Security 7.4.3... 4 Related

More information

CSC IT practix Recommendations

CSC IT practix Recommendations CSC IT practix Recmmendatins CSC Healthcare 28th January 2014 Versin 3 www.csc.cm/glbalhealthcare Cntents 1 Imprtant infrmatin 3 2 IT Specificatins 4 2.1 Wrkstatins... 4 2.2 Minimum Server with 1-5 wrkstatins

More information

System Business Continuity Classification

System Business Continuity Classification Business Cntinuity Prcedures Business Impact Analysis (BIA) System Recvery Prcedures (SRP) System Business Cntinuity Classificatin Cre Infrastructure Criticality Levels Critical High Medium Lw Required

More information

Installation Guide Marshal Reporting Console

Installation Guide Marshal Reporting Console INSTALLATION GUIDE Marshal Reprting Cnsle Installatin Guide Marshal Reprting Cnsle March, 2009 Cntents Intrductin 2 Supprted Installatin Types 2 Hardware Prerequisites 3 Sftware Prerequisites 3 Installatin

More information

State of Wisconsin Division of Enterprise Technology (DET) Distributed Database Hosting Service Offering Definition (SOD)

State of Wisconsin Division of Enterprise Technology (DET) Distributed Database Hosting Service Offering Definition (SOD) State f Wiscnsin Divisin f Enterprise Technlgy (DET) Distributed Database Hsting Service Offering Definitin (SOD) Distributed Database Hsting SOD Page 1 12/9/2010 Dcument Revisin Histry (Majr Pst Publishing

More information

How to deploy IVE Active-Active and Active-Passive clusters

How to deploy IVE Active-Active and Active-Passive clusters Hw t deply IVE Active-Active and Active-Passive clusters Overview Juniper Netscreen SA and SM series appliances supprt Active/Passive r Active/Active cnfiguratins acrss a LAN r a WAN t prvide high availability,

More information

DVS Enterprise Test Results for Microsoft Lync 2013 and Citrix XenDesktop 7. Dell Client Cloud Computing Engineering Revision: 1.

DVS Enterprise Test Results for Microsoft Lync 2013 and Citrix XenDesktop 7. Dell Client Cloud Computing Engineering Revision: 1. DVS Enterprise Test Results fr Micrsft Lync 2013 and Citrix XenDesktp 7 Dell Client Clud Cmputing Engineering Revisin: 1.0 11/6/13 THIS DOCUMENT IS FOR INFORMATIONAL PURPOSES ONLY, AND MAY CONTAIN TYPOGRAPHICAL

More information

Readme File. Purpose. Introduction to Data Integration Management. Oracle s Hyperion Data Integration Management Release 9.2.

Readme File. Purpose. Introduction to Data Integration Management. Oracle s Hyperion Data Integration Management Release 9.2. Oracle s Hyperin Data Integratin Management Release 9.2.1 Readme Readme File This file cntains the fllwing sectins: Purpse... 1 Intrductin t Data Integratin Management... 1 Data Integratin Management Adapters...

More information

Information Services Hosting Arrangements

Information Services Hosting Arrangements Infrmatin Services Hsting Arrangements Purpse The purpse f this service is t prvide secure, supprted, and reasnably accessible cmputing envirnments fr departments at DePaul that are in need f server-based

More information

Licensing the Core Client Access License (CAL) Suite and Enterprise CAL Suite

Licensing the Core Client Access License (CAL) Suite and Enterprise CAL Suite Vlume Licensing brief Licensing the Cre Client Access License (CAL) Suite and Enterprise CAL Suite Table f Cntents This brief applies t all Micrsft Vlume Licensing prgrams. Summary... 1 What s New in This

More information

State of Wisconsin DET Dedicated Virtual Host Services Offering Definition

State of Wisconsin DET Dedicated Virtual Host Services Offering Definition State f Wiscnsin DET Dedicated Virtual Hst Services Offering Definitin Dcument Revisin Histry Date Versin Creatr Ntes 10/29/2010 1.0 Phil Staley Initial draft 11/3/2010 1.1 Phil Staley Ryan McKee Secnd

More information

Getting Started Guide

Getting Started Guide AnswerDash Resurces http://answerdash.cm Cntextual help fr sales and supprt Getting Started Guide AnswerDash is cmmitted t helping yu achieve yur larger business gals. The utlined pre-launch cnsideratins

More information

StoneFly M-Series DR Backup Appliance

StoneFly M-Series DR Backup Appliance StneFly M-Series DR Backup Appliance StneFly M-Series f DR Backup Appliances is a purpse-built backup system in ne easy t manage appliance. The StneFly M-Series prvides yu with an affrdable and ttal backup

More information

SANsymphony-V Storage Virtualization Software Installation and Getting Started Guide. February 5, 2015 www.datacore.com

SANsymphony-V Storage Virtualization Software Installation and Getting Started Guide. February 5, 2015 www.datacore.com SANsymphny-V Strage Virtualizatin Sftware Installatin and Getting Started Guide February 5, 2015 www.datacre.cm This dcument is the prperty f DataCre Sftware. It is intended slely as an aid fr installing

More information

Readme File. Purpose. What is Translation Manager 9.3.1? Hyperion Translation Manager Release 9.3.1 Readme

Readme File. Purpose. What is Translation Manager 9.3.1? Hyperion Translation Manager Release 9.3.1 Readme Hyperin Translatin Manager Release 9.3.1 Readme Readme File This file cntains the fllwing sectins: Purpse... 1 What is Translatin Manager 9.3.1?... 1 Cmpatible Sftware... 2 Supprted Internatinal Operating

More information

April 3, 2014. Release Notes

April 3, 2014. Release Notes April 3, 2014 Release Ntes Cntacting Lestream Lestream Crpratin 411 Waverley Oaks Rd. Suite 316 Waltham, MA 02452 USA http://www.lestream.cm Telephne: +1 781 890 2019 Fax: +1 781 688 9338 T submit an enhancement

More information

AvePoint High Speed Migration Supplementary Tools

AvePoint High Speed Migration Supplementary Tools AvePint High Speed Migratin Supplementary Tls User Guide Issued April 2016 1 Table f Cntents Intrductin... 3 MD5 Value Generatr Tl... 3 Azure Data Uplad Tl... 3 Dwnlading and Unpacking the Tl... 4 Using

More information

Understand Business Continuity

Understand Business Continuity Understand Business Cntinuity Lessn Overview In this lessn, yu will learn abut: Business cntinuity Data redundancy Data availability Disaster recvery Anticipatry Set What methds can be emplyed by a system

More information

The Importance Advanced Data Collection System Maintenance. Berry Drijsen Global Service Business Manager. knowledge to shape your future

The Importance Advanced Data Collection System Maintenance. Berry Drijsen Global Service Business Manager. knowledge to shape your future The Imprtance Advanced Data Cllectin System Maintenance Berry Drijsen Glbal Service Business Manager WHITE PAPER knwledge t shape yur future The Imprtance Advanced Data Cllectin System Maintenance Cntents

More information

StoneFly Z-Series DR Backup Appliance

StoneFly Z-Series DR Backup Appliance StneFly Z-Series DR Backup Appliance StneFly Z-Series f DR Backup Appliances is a purpse-built backup system in ne easy t manage appliance. The StneFly Z-Series prvides yu with a ttal backup slutin fr

More information

2008 BA Insurance Systems Pty Ltd

2008 BA Insurance Systems Pty Ltd 2008 BA Insurance Systems Pty Ltd BAIS have been delivering insurance systems since 1993. Over the last 15 years, technlgy has mved at breakneck speed. BAIS has flurished in this here tday, gne tmrrw sftware

More information

SaaS Listing CA Cloud Service Management

SaaS Listing CA Cloud Service Management SaaS Listing CA Clud Service Management 1. Intrductin This dcument prvides standards and features that apply t the CA Clud Service Management (CSM) SaaS ffering prvided t the Custmer and defines the parameters

More information

Identify Major Server Hardware Components

Identify Major Server Hardware Components 98-365 Windws Server Administratin Fundamentals Identify Majr Server Hardware Cmpnents 98-365 Windws Server Administratin Fundamentals Lessn Overview In this lessn, yu will learn: Server frm factrs Server

More information

Implementing SQL Manage Quick Guide

Implementing SQL Manage Quick Guide Implementing SQL Manage Quick Guide The purpse f this dcument is t guide yu thrugh the quick prcess f implementing SQL Manage n SQL Server databases. SQL Manage is a ttal management slutin fr Micrsft SQL

More information

Have some knowledge of how queries execute. Must be able to read a query execution plan and understand what is happening.

Have some knowledge of how queries execute. Must be able to read a query execution plan and understand what is happening. Curse 2786B: Designing a Micrsft SQL Server 2005 Infrastructure Abut this Curse This tw-day instructr-led curse prvides database administratrs wrking in enterprise envirnments with the knwledge and skills

More information

BASIC TECHNICAL FEATURE DESCRIPTION

BASIC TECHNICAL FEATURE DESCRIPTION BASIC TECHNICAL FEATURE DESCRIPTION AUDRIGA EMAIL AND GROUPWARE MIGRATION SERVICE Versin 1.3 Datum 20.09.2013 Kntakt Hans-Jörg Happel (happel@audriga.cm) TECHNICAL FEATURE DESCRIPTION This is a basic technical

More information

Optimal Payments Extension. Supporting Documentation for the Extension Package. 20140225 v1.1

Optimal Payments Extension. Supporting Documentation for the Extension Package. 20140225 v1.1 Optimal Payments Extensin Supprting Dcumentatin fr the Extensin Package 20140225 v1.1 Revisin Histry v1.1 Updated Demac Media branding v1.0 Initial Dcument fr Distributin supprt@ptimalpayments.cm Page

More information

Copyright 2013, SafeNet, Inc. All rights reserved. http://www.safenet-inc.com/ We have attempted to make these documents complete, accurate, and

Copyright 2013, SafeNet, Inc. All rights reserved. http://www.safenet-inc.com/ We have attempted to make these documents complete, accurate, and ii Cpyright 2013, SafeNet, Inc. All rights reserved. http://www.safenet-inc.cm/ We have attempted t make these dcuments cmplete, accurate, and useful, but we cannt guarantee them t be perfect. When we

More information

System Business Continuity Classification

System Business Continuity Classification System Business Cntinuity Classificatin Business Cntinuity Prcedures Infrmatin System Cntingency Plan (ISCP) Business Impact Analysis (BIA) System Recvery Prcedures (SRP) Cre Infrastructure Criticality

More information

2. When logging is used, which severity level indicates that a device is unusable?

2. When logging is used, which severity level indicates that a device is unusable? Last updated by Admin at March 3, 2015. 1. What are the mst cmmn syslg messages? thse that ccur when a packet matches a parameter cnditin in an access cntrl list link up and link dwn messages utput messages

More information

Microsoft Certified Database Administrator (MCDBA)

Microsoft Certified Database Administrator (MCDBA) Micrsft Certified Database Administratr (MCDBA) 460 hurs Curse Overview/Descriptin The MCDBA prgram and credential is designed fr individuals wh want t demnstrate that they have the necessary skills t

More information

Best Practices for Optimizing Performance and Availability in Virtual Infrastructures

Best Practices for Optimizing Performance and Availability in Virtual Infrastructures Best Practices fr Optimizing Perfrmance and Availability in Virtual Infrastructures www.nimsft.cm Best Practices fr Optimizing Perfrmance and Availability in Virtual Infrastructures PAGE 2 Table f Cntents

More information

FUJITSU Software ServerView Suite ServerView PrimeCollect

FUJITSU Software ServerView Suite ServerView PrimeCollect User Guide - English FUJITSU Sftware ServerView Suite ServerView PrimeCllect Editin February 2015 Cmments Suggestins Crrectins The User Dcumentatin Department wuld like t knw yur pinin f this manual. Yur

More information

ATL: Atlas Transformation Language. ATL Installation Guide

ATL: Atlas Transformation Language. ATL Installation Guide ATL: Atlas Transfrmatin Language ATL Installatin Guide - versin 0.1 - Nvember 2005 by ATLAS grup LINA & INRIA Nantes Cntent 1 Intrductin... 3 2 Installing ADT frm binaries... 3 2.1 Installing Eclipse and

More information

A Beginner s Guide to Building Virtual Web Servers

A Beginner s Guide to Building Virtual Web Servers A Beginner s Guide t Building Virtual Web Servers Cntents Intrductin... 1 Why set up a web server?... 2 Installing Ubuntu 13.04... 2 Netwrk Set Up... 3 Installing Guest Additins... 4 Updating and Upgrading

More information

Release Notes. Dell SonicWALL Email Security 8.0 firmware is supported on the following appliances: Dell SonicWALL Email Security 200

Release Notes. Dell SonicWALL Email Security 8.0 firmware is supported on the following appliances: Dell SonicWALL Email Security 200 Email Security Dell SnicWALL Email Security 8.0 SnicOS Cntents System Cmpatibility... 1 Enhancements in Email Security 8.0... 3 Knwn Issues... 13 Reslved Issues... 13 Upgrading t Email Security 8.0...

More information

Cloud Services Frequently Asked Questions FAQ

Cloud Services Frequently Asked Questions FAQ Clud Services Frequently Asked Questins FAQ Revisin 1.0 6/05/2015 List f Questins Intrductin What is the Caradigm Intelligence Platfrm (CIP) clud? What experience des Caradigm have hsting prducts like

More information

Integrating With incontact dbprovider & Screen Pops

Integrating With incontact dbprovider & Screen Pops Integrating With incntact dbprvider & Screen Pps incntact has tw primary pints f integratin. The first pint is between the incntact IVR (script) platfrm and the custmer s crprate database. The secnd pint

More information

Release Notes. V8 Peregrine

Release Notes. V8 Peregrine Release Ntes V8 Peregrine Nvember 2014 Table f Cntents IMPORTANT NOTES FOR THIS RELEASE... 3 WHAT S NEW... 3 ENTERPRISE SERVER EDITION (ESE)... 3 New indexing engine that has the fllwing advantages:...

More information

GETTING STARTED With the Control Panel Table of Contents

GETTING STARTED With the Control Panel Table of Contents With the Cntrl Panel Table f Cntents Cntrl Panel Desktp... 2 Left Menu... 3 Infrmatin... 3 Plan Change... 3 Dmains... 3 Statistics... 4 Ttal Traffic... 4 Disk Quta... 4 Quick Access Desktp... 4 MAIN...

More information

ScaleIO Security Configuration Guide

ScaleIO Security Configuration Guide ScaleIO Security Cnfiguratin Guide 1 Intrductin This sectin prvides an verview f the settings available in ScaleIO t ensure secure peratin f the prduct: Security settings are divided int the fllwing categries:

More information

Best Practice - Pentaho BA for High Availability

Best Practice - Pentaho BA for High Availability Best Practice - Pentah BA fr High Availability This page intentinally left blank. Cntents Overview... 1 Pentah Server High Availability Intrductin... 2 Prerequisites... 3 Pint Each Server t Same Database

More information

Telelink 6. Installation Manual

Telelink 6. Installation Manual Telelink 6 Installatin Manual Table f cntents 1. SYSTEM REQUIREMENTS... 3 1.1. Hardware Requirements... 3 1.2. Sftware Requirements... 3 1.2.1. Platfrm... 3 1.2.1.1. Supprted Operating Systems... 3 1.2.1.2.

More information

webnetwork Pre-Installation Configuration Checklist

webnetwork Pre-Installation Configuration Checklist webnetwrk Pre-Installatin Cnfiguratin Checklist Stneware, Inc. Prduct: webnetwrk versin 6.2 and higher Dcument revisin: 2-10-2015 1 Intrductin This dcument is intended t prvide infrmatin that will assist

More information

risk2value System Requirements

risk2value System Requirements aveds business slutins gmbh risk2value System Requirements March 2014 aveds business slutins gmbh Page 1 RISK2VALUE SYSTEM REQUIREMENTS aveds risk2value is based n Micrsft-Technlgy. This dcument gives

More information

TaskCentre v4.5 MS SQL Server Trigger Tool White Paper

TaskCentre v4.5 MS SQL Server Trigger Tool White Paper TaskCentre v4.5 MS SQL Server Trigger Tl White Paper Dcument Number: PD500-03-02-1_0-WP Orbis Sftware Limited 2010 Table f Cntents COPYRIGHT... 1 TRADEMARKS... 1 INTRODUCTION... 2 Overview... 2 Features...

More information

o 1.1 - How AD Query Works o 1.2 - Installation Requirements o 2.1 - Inserting your License Key o 2.2 - Selecting and Changing your Search Domain

o 1.1 - How AD Query Works o 1.2 - Installation Requirements o 2.1 - Inserting your License Key o 2.2 - Selecting and Changing your Search Domain SysOp Tls Active Directry Management sftware Active Directry Query v1.x Sftware Installatin and User Guide Updated September 29, 2008 In This Dcument: 1.0 Intrductin 1.1 - Hw AD Query Wrks 1.2 - Installatin

More information

Blue Link Solutions Terminal Server Configuration How to Install Blue Link Solutions in a Terminal Server Environment

Blue Link Solutions Terminal Server Configuration How to Install Blue Link Solutions in a Terminal Server Environment Blue Link Slutins Terminal Server Cnfiguratin Hw t Install Blue Link Slutins in a Terminal Server Envirnment Prepared by: Darren Myher April 9, 2002 Table f Cntents Backgrund... 2 Applicatin Server mde

More information

Diagnostic Manager Change Log

Diagnostic Manager Change Log Diagnstic Manager Change Lg Updated: September 8, 2015 4.4.4090 Features and Issues Supprt fr Office 365 Tenants Yu can nw: Mnitr the status f Office 365 Services (including SharePint Online, Exchange

More information

Software Distribution

Software Distribution Sftware Distributin Quantrax has autmated many f the prcesses invlved in distributing new cde t clients. This will greatly reduce the time taken t get fixes laded nt clients systems. The new prcedures

More information

Systems Support - Extended

Systems Support - Extended 1 General Overview This is a Service Level Agreement ( SLA ) between and the Enterprise Windws Services t dcument: The technlgy services the Enterprise Windws Services prvides t the custmer. The targets

More information

INTERMEDIATE CAD FILE MANAGEMENT

INTERMEDIATE CAD FILE MANAGEMENT INTERMEDIATE CAD FILE MANAGEMENT Intrductin File mismanagement is the dwnfall f many brilliant individuals. If yu are wise, yu wn't be ne f the peple wh meet disaster due t pr file management. Cmputers

More information

HP ExpertOne. HP2-T21: Administering HP Server Solutions. Table of Contents

HP ExpertOne. HP2-T21: Administering HP Server Solutions. Table of Contents HP ExpertOne HP2-T21: Administering HP Server Slutins Industry Standard Servers Exam preparatin guide Table f Cntents Overview 2 Why take the exam? 2 HP ATP Server Administratr V8 certificatin 2 Wh shuld

More information

Service Level Agreement (SLA) Hosted Products. Netop Business Solutions A/S

Service Level Agreement (SLA) Hosted Products. Netop Business Solutions A/S Service Level Agreement (SLA) Hsted Prducts Netp Business Slutins A/S Cntents 1 Service Level Agreement... 3 2 Supprt Services... 3 3 Incident Management... 3 3.1 Requesting service r submitting incidents...

More information

Access the SQLsafe Release Notes

Access the SQLsafe Release Notes Access the SQLsafe Release Ntes SQLsafe is a pwerful backup and recvery slutin that greatly reduces backup and recvery time, minimizes strage requirements, and prvides enterprise management capabilities

More information

Bitrix Intranet. Product Requirements

Bitrix Intranet. Product Requirements Bitrix Intranet Prduct Requirements Bitrix Intranet: Prduct Requirements Bitrix Intranet is a highly secure, turnkey intranet slutin fr small and medium-sized businesses designed fr effective cllabratin,

More information

Identify Storage Technologies and Understand RAID

Identify Storage Technologies and Understand RAID 98-365 Windws Server Administratin Fundamentals Identify Strage Technlgies and Understand RAID 98-365 Windws Server Administratin Fundamentals Lessn Overview In this lessn, yu will learn: Lcal strage ptins

More information

Preparing to Deploy Reflection : A Guide for System Administrators. Version 14.1

Preparing to Deploy Reflection : A Guide for System Administrators. Version 14.1 Preparing t Deply Reflectin : A Guide fr System Administratrs Versin 14.1 Table f Cntents Table f Cntents... 2 Preparing t Deply Reflectin 14.1:... 3 A Guide fr System Administratrs... 3 Overview f the

More information

Volume Licensing reference guide. Windows Server 2012 R2

Volume Licensing reference guide. Windows Server 2012 R2 Vlume Licensing reference guide Windws Server 2012 R2 Intrductin This guide can help Micrsft Vlume Licensing custmers understand hw Windws Server 2012 R2 is licensed thrugh Micrsft Vlume Licensing prgrams.

More information

Project Startup Report Presented to the IT Committee June 26, 2012

Project Startup Report Presented to the IT Committee June 26, 2012 Prject Name: SOS File 2.0 Agency: Secretary f State Business Unit/Prgram Area: Secretary f State Prject Spnsr: Al Jaeger Prject Manager: Beverly Maitland Prject Startup Reprt Presented t the IT Cmmittee

More information

Table of Contents. This document is for informational purposes only. MICROSOFT MAKES NO WARRANTIES, EXPRESS OR IMPLIED, IN THIS SUMMARY.

Table of Contents. This document is for informational purposes only. MICROSOFT MAKES NO WARRANTIES, EXPRESS OR IMPLIED, IN THIS SUMMARY. Table f Cntents Tp Pricing and Licensing Questins... 2 Why shuld custmers be excited abut Micrsft SQL Server 2012?... 2 What are the mst significant changes t the pricing and licensing fr SQL Server?...

More information

Tech Notes Promise RAID

Tech Notes Promise RAID Tech Ntes Prmise RAID 03/05/ Purpse: T increase familiarity with the Prmise RAID systems in bth Windws Based and DOS based sftware, including the crrect methd fr rebuilding arrays, crrecting drive errrs,

More information

ROSS RepliWeb Operations Suite for SharePoint. SSL User Guide

ROSS RepliWeb Operations Suite for SharePoint. SSL User Guide ROSS RepliWeb Operatins Suite fr SharePint SSL User Guide Sftware Versin 2.5 March 18, 2010 RepliWeb, Inc., 6441 Lyns Rad, Ccnut Creek, FL 33073 Tel: (954) 946-2274, Fax: (954) 337-6424 E-mail: inf@repliweb.cm,

More information

STIOffice Integration Installation, FAQ and Troubleshooting

STIOffice Integration Installation, FAQ and Troubleshooting STIOffice Integratin Installatin, FAQ and Trubleshting Installatin Steps G t the wrkstatin/server n which yu have the STIDistrict Net applicatin installed. On the STI Supprt page at http://supprt.sti-k12.cm/,

More information

Architecting HP Server Solutions

Architecting HP Server Solutions HP ExpertOne exam preparatin guide Architecting HP Server Slutins Exam descriptin This certificatin attests that yu can: gather and analyze business and technical requirements and then plan and design

More information

E-Biz Web Hosting Control Panel

E-Biz Web Hosting Control Panel 1 f 38 E-Biz Web Hsting Cntrl Panel This dcument has been created t give yu a useful insight in t the Hsting Cntrl Panel available with E-Biz hsting services. Please nte: Optins available are dependent

More information

TaskCentre v4.5 Send Message (SMTP) Tool White Paper

TaskCentre v4.5 Send Message (SMTP) Tool White Paper TaskCentre v4.5 Send Message (SMTP) Tl White Paper Dcument Number: PD500-03-17-1_0-WP Orbis Sftware Limited 2010 Table f Cntents COPYRIGHT 1 TRADEMARKS 1 INTRODUCTION 2 Overview 2 FEATURES 2 GLOBAL CONFIGURATION

More information