MV CABLE TYPE C 33-226



Similar documents
MEDIUM VOLTAGE CABLES Up to and including 36 KV

FLEXIBLE INDUSTRIAL CABLES H07RN-F TENAFLEX SR

CONFLEX ELECTRIC CABLE

High Voltage Systems. Today. The history of cables

Gulf Cable & Electrical Ind. Co.

CABLES FOR PHOTOVOLTAIC SOLAR ENERGY INSTALLATIONS FOR CLEAN ENERGY

XLPE Land Cable Systems User s Guide. Rev 5

6 ELECTRICAL PARAMETERS

EDS KV TRIPLEX CABLE

THE PATHWAY TO POWER HIGH-VOLTAGE CABLES

Fibre optic cables MDIC LSZH

KNOW YOUR OPTIONS: 230 KV POWER CABLES

Current Ratings. TABLE BEC 107. (Continued) Current ratings for 6350/11000 volts grade PILC/SWA/PVC cable to BS6480/69

APPLICATION ORIENTED DESIGN OF CABLES

Section kv Power Cables

Cables, Cable Laying & Accessories Manual

Power and Wiring Cables

KNOW YOUR OPTIONS: 69 KV XLPE POWER CABLE

Network Standard Advice No. 1420C 9/6/2011

Removal of EP SP High Voltage Cable

FIRE RESISTANT CABLE CONSTRUCTION OF CABLES

HIGH VOLTAGE XLPE CABLE SYSTEMS. Technical User Guide

XLPE рower cables. 2 Modern solutions for power cables I Estralin HVC

VIPERFLEX ELECTRIC CABLE

Cable Consulting International

Chemical resistance Accidental

Fire retardant IEC

We specialize in low voltage cables including: Stranded Single Cable H07V-R Flexible Single Cable H05V-K

M. GELDON Brugg Kabel CZ. Ing. D. RÚŽEK PREdistribuce. Switzerland Czech Rep. Czech Rep. Czech Rep., Switzerland Germany

3.6/6 kv XLPE insulated cables 5. 6/10 kv XLPE insulated cables /15 kv XLPE insulated cables /20 kv XLPE insulated cables 35

The Quality Connection. BETAflam Fire Resistant Safety Cables

MEDIUM VOLTAGE POWER CABLES

How To Monitor Water Penetration In A Cable Screen

6-36kV Medium Voltage Underground Power Cables. XLPE insulated cables

Quality Reliability Innovation. ISO 9001 : 2000 CERTIFIED BY AFAQ No. QUAL / 1997 / 7034 a COPPER TELECOMMUNICATION CABLES

UGVCL/SP/591/11KV HT AB CABLE

HV Submarine Cable Systems Design, Testing and Installation

VDE-approved PVC-Control Cables

ENERGY. TECWATER S1BN8-F 0,6/1 kv. Cable for Water Application

LEAD FREE FIREX. Interlock Armored Cables TECK90 and MC Industrial Cables. w w w. n e x a n s e n e r g y. c o m

Cable flexibility Flexible. Chemical resistance Accidental

CAVEL VS80205 MADE IN ITALY 1000 V

COAX Cables Radio Frequency Cables

Offshore Transformer Platform. Technical Standard. Energinet.dk. HV, MV, LV and Signal Cables and Cable Routing

Tri-Rated Flexible PVC Equipment Wire

ENERGY. TECSUN DUO (PV) Twin Cables for Photovoltaics

R=Required by Lab S=May be subcontracted IEC SYSTEM FOR CONFORMITY TESTING AND CERTIFICATION OF ELECTRICAL EQUIPMENT COMMITTEE OF TESTING LABORATORIES

HVDC Light Cables. Submarine and land power cables

Fault location on power cables. Fault location on power cables

PROFIBUS cable. for PROFIBUS-PA and -DP 10/ EN

with coloured cores and overall copper screen UL/CSA... 17

Specializing in the cable business for over 38 years, PT. SUPREME CABLE

Product descriptions and characteristics shown in this content have no legal effect. Nexans China has the right to change product specifications

INTERNATIONAL STANDARD

Fire Resistant Cables

HIGH- AND EXTRA-HIGH-VOLTAGE GLOBAL CABLE SYSTEM SOLUTIONS Rely On Our Experience... Experience Our Capabilities

Festoon 715 P PUR cable for flexible application in festoon systems

Global cable expertise for rolling stock

Temperature Permissible ambient temperature. Weather Resistance to severe weather conditions. Impacts Cable mechanical resistance to impacts

E-Highway2050 WP3 workshop April 15 th, 2014 Brussels

Communication, Signal & Data Cables

4 IX D N E P P A Installation methods Current-carrying capacity and voltage drop for cables Reference method IET Wiring Matters

The color scheme for the fibers in the cable complies with the Telcordia (formerly Bellcore) specification.

High Voltage Cable Systems

Series 8146/5-V37 and Series 8150/5-V37

TECHNICAL SPECIFICATION OF 11 / 22 KV XLPE POWER CABLE FOR SUB-STATION

Corporate Profile ROYAL. MODERN ROYAL ELECTRIC Ideal Power Solution MRE ELECTRICAL, INSTRUMENTATION & COMMUNICATION SYSTEMS

SCHEDULE ' A ' TECHNICAL SPECIFICATION FOR SINGLE CORE,UNARMOURED L.T.XLPE POWER CABLE FOR DISTRIBUTION NETWORK IN MAHARASHTRA

ISO 9001 ISO CABLES AND WIRES CATALOGUE 2008

Standard Buccaneer - Ethernet

ECS INSTALLATION OF UNDERGROUND CABLES - LV TO 132KV

Effects of the circulating sheath currents in the magnetic field generated by an underground power line

VOLTS - Copper conductor PVC insulated SSA 1320, IEC & BS 6004 HO 7V - U With Solid Conductor - TYPE IEC 01. Insulation Thickness

100% EMI Emission Containment

Real Time Monitoring of Power Cables by Fibre Optic Technologies Tests, Applications and Outlook

Gulf Cable & Electrical Ind. Co.

Flexible Control Cables

Respecting the environment

Sizing conductors and selecting protection devices

GOWN. Central Loose Tube Cables Outdoor, Steel Wire Armor (SWA) A-DQ(ZN)2YB2Y Full Rodent Protection. Ordering Information.

Airdac CNE and SNE, 600/1000V, Polyethylene Sheath, SANS 1507, NRS 063 & NRS 017

OPTICAL FIBER CABLES

Two different types of cables are used in primary airfield lighting circuits: - unshielded cables and - shielded cables

PROFIBUS cable. PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications

TECHNICAL SPECIFICATIONS OF 66 KV 1C 300 SQ.MM. XLPE POWER CABLE FOR UNDER GROUND LINE

THORNE & DERRICK UK TEL FAX TEL FAX

Modeling of Transmission Lines

International Electrotechnical Commission Standards

TECHNICAL SPECIFICATIONS OF 66 KV 1C 630 SQ.MM. XLPE POWER CABLE FOR UNDER GROUND LINE

BETAtrans. Cables and Systems for Rolling Stock. Edition 2006

SUITABILITY OF DIFFERENT TEST VOLTAGES FOR ON-SITE TESTING OF XLPE CABLE SYSTEMS

Stephen G. Whitley, Senior Vice President & Chief Operating Officer

Instrumentation Cable Power Cable Assembly Solutions...32

Outside Telephone Cable

AORC Technical meeting 2014

Handling and Installation of Cables up to and including 33kV

CABLE ACCESSORIES kv

Ampacity simulation of a high voltage cable to connecting off shore wind farms

FIBRA OPTICA INTERIOR/EXTERIOR TIGHT BUFFER

Building Cables and Wires

Transcription:

MV CABLE TYPE C 33-226 Standards : CENELEC HD 620 C 33-226 Rated voltage Rated voltage : 12/20 (24) kv Design 1 Stranded aluminium, class 2 conductor 2 Extruded conducting screen on conductor 3 XLPE insulation 4 Grooved, strippable, extruded conducting screen on insulation 5 Swellable powder for longitudinal watertightness under the metallic screen 6 Aluminium foil longitudinally applied with an overlap and stuck to the outer sheath 7 PE sheath (*) 8 The three phase conductors may be bundled with a long lay length (*) Red sheath for underground connections. Grey sheath for overhead connections and laying in tunnels Application Specially designed for power distribution networks; designed to be buried directly in the ground. Excellent Good Medium (**) (**) only the cable with a grey sheath in flame retardant (C2 of NFC 32-070 or IEC 60332-1) Using minimum bending radius during laying (single core or bundle) : 26 x diameter of a phase conductor minimum bending radius after laying (single core or bundle) : 13 x diameter of a phase conductor Maximum allowable temperature During continuous service: 90 C During short-circuit: 250 C 1

C 33-226 (continued) Identification and outer marking SILEC Day Year C 33 226 Cross-section Al 12/20 (24) kv SIPRELEC 23 POPY (1) G2 SC 0,7 AT T -10/50 (2) PHASE 1 (or 2 or 3) (1) Reference for the cable fittings (2) T 0/35 for grey-sheathed cable Length marking on one conductor. Dimension CABLE outer diameter mm weight kg/km Maximum allowable pulling force, dan 1x50 mm² 29,0 700 150 1x95 mm² 32,0 950 285 1x150 mm² 32,0 1000 450 1x240 mm² 36,5 1400 720 3x50 mm² 62.5 2100 450 3x95 mm² 69,0 2800 855 3x150 mm² 69,0 3050 1350 3x240 mm² 78,5 4150 2160 Electrical characteristics Cross-section, mm² Item 50 95 150 240 DC maximum resistance of the conductor at 20 C, Ω / km 0,641 0,320 0,206 0,125 AC apparent resistance of the conductor at 90 C, Ω / km (1) 0,820 0,410 0,265 0,160 Self-induction coefficient, mh / km (1) 0,440 0,400 0,350 0,330 Capacitance, µf / km 0,180 0,220 0,300 0,360 (1) These values are applicable to a three-phase system made of three conductors bundled or in joined trefoil formation. For other cross-sections, please contact us. 2

C 33-226 (continued) Maximum allowable ampacity Cross section, mm² Buried Winter Summer 50 205 170 95 300 245 150 385 310 240 505 410 Ampacity in Ampere is calculated for a three phase system, with the below thermal hypothesis, without any electric parallel nor thermal proximity.: SUMMER: soil temperature : 20 C soil thermal resistivity : 1,2 K m / W WINTER: soil temperature : 10 C soil thermal resistivity : 0,85 K m / W For other cross-sections, please contact us. Allowable ampacity during short-circuit in the screen Cross-section, mm² Icc, A during 1 sec 50 2500 95 2700 150 2700 240 3200 For other cross-sections, please contact us. 3

ALL GROUND CABLE type UTE C 33-223 or NF C 33-223 Standards : UTE C 33-223 of December 1999 CENELEC HD 620 NFC 33-223 IEC 60 502-2 Rated voltage This design can be manufactured for all rated voltage of IEC 60502-2 Design Stranded conductor, class 2 Extruded conducting screen on conductor XLPE insulation Grooved, strippable, extruded conducting screen on insulation Swellable powder for longitudinal watertightness under the metallic screen Aluminium foil longitudinally applied with an overlap and stuck to the outer sheath, PVC sheath, Strippable, grooved, TPR sheath The three phase conductors may be bundled with a long lay length Using Cable for MV distribution networks. It can be buried directly in all grounds, and is specially adapted for «hard» ground. Mainly, its design prevents from adding sand in the trench bottom, and the trench can be filled back with original soil. Very good Good Medium Setting up the minimum bending radius during installation is the same that NF C 33-223 or UTE C 33-223 (see dimension) the minimum bending radius after installation is the same that NF C 33-223 or UTE C 33-223 (see dimension) Fitting of a termination or a joint : - Once the grooved outer sheath has been removed with the usual tool, the fitting of a termination or a joint is the same as for NF C 33-223 or UTE C 33-223 4

All Ground Cable type UTE C 33-223 or NF C 33-223 (continued) Maximum allowable temperatures Continuous service: 90 C Short-circuit in the conductor: 250 C Short-circuit in the metallic screen : 200 C Identification and outer marking SILEC «Batch number» «Standard» cross section AL 12/20 (24) kv SIPRELEC 23 Ec=0.2 mm PHASE 1 (or 2 or 3) ALL GROUND CABLE Length marking can be indicated on one phase conductor. Dimension outer diameter weight Minimum bending Minimum bending radius Maximum pulling force ARTICLE radius after during laying laying mm mm kg/km mm dan 1 x 50 mm² 39,5 1400 400 800 150 1 x 95 mm² 42.5 1700 450 900 285 1 x 150 mm² 43,5 1850 450 900 450 1 x 240 mm² 48,0 2350 500 1000 720 3 x 50 mm² 84,5 4200 400 800 450 3 x 95 mm² 92,0 5100 450 900 855 3 x 150 mm² 93,5 5500 450 900 1350 3 x 240 mm² 103,5 7000 500 1000 2160 Electrical characteristics Cross Section, mm² 50 95 150 240 Item Maximum DC resistance at 20 C, Ω / km 0,641 0,320 0,206 0,125 AC apparent resistance of the conductor at 90 C, Ω / km 0,820 0,410 0,260 0,160 Self-induction coefficient mh / km (1) 0,500 0,450 0,420 0,380 Capacitance, µf / km 0,180 0,210 0,290 0,360 (1) Calculated for three bundled cables or three cables in a joined trefoil formation. For other sections, call us. 5

All Ground Cable type UTE C 33-223 or NF C 33-223 (continued) Maximum allowable ampacity Cross section, mm² Buried cables Winter Summer 50 195 160 95 285 235 150 360 300 240 480 395 Ampacity is indicated in amps for a three-phase system without any thermal or electrical proximity under following thermal conditions: SUMMER: soil temperature : 20 C soil thermal resistivity : 1,2 K m / W WINTER: soil temperature : 10 C soil thermal resistivity : 0,85 K m / W For other sections, call us. 6

ALL GROUND CABLE TM type C 33-226 Standards : UTE C 33 226, HD 620, Rated voltage Rated voltage: 12/20 (24) kv Design Stranded conductor, class 2 Extruded conducting screen on conductor XLPE insulation Grooved, strippable, extruded conducting screen on insulation Swellable powder for longitudinal watertightness under the metallic screen Aluminium foil longitudinally applied with an overlap and stuck to the outer sheath, PE sheath, Strippable, grooved, TPR sheath The three phase conductors may be bundled with a long lay length Using Cable for MV distribution networks. It can be buried directly in all grounds, and is specially adapted for «hard» ground. Mainly, its design prevents from adding sand in the trench bottom, and the trench can be filled with original soil. Very good Good Medium Setting up the minimum bending radius during installation is the same that C 33-226 (see dimension) the minimum bending radius after installation is the same C 33-226 (see dimension) Fitting of a termination or a joint : - Once the grooved outer sheath has been removed with the usual tool, the fitting a termination or a joint is the same as for standard MV cables 7

All Ground Cable type C 33-226 (continued) Maximum allowable temperatures Continuous service: 90 C Short-circuit in the conductor: 250 C Identification and outer marking SILEC Day Year C 33 226 Cross-section Al 12/20 (24) kv SIPRELEC 23 POPY (1) G2 SC 0,7 AT T -10/50 (2) PHASE 1 (or 2 or 3) ALL GROUND CABLE (3) Reference for the cable fittings (4) T 0/35 for grey-sheathed cable Metric marking can be indicated on one phase conductor. Dimension ARTICLE outer diameter weight Minimum bending radius after laying Minimum bending radius during laying mm Maximum pulling force mm kg/km mm dan 1 x 50 mm² 38,0 1200 400 800 150 1 x 95 mm² 41,0 1450 450 900 285 1 x 150 mm² 41,0 1550 450 900 450 1 x 240 mm² 45,5 1950 500 1000 720 3 x 50 mm² 81,0 3550 400 800 450 3 x 95 mm² 88,0 4350 450 900 855 3 x 150 mm² 88,0 4600 450 900 1350 3 x 240 mm² 97,5 5900 500 1000 2160 8

All Ground Cable type C 33-226 (continued) Electrical characteristics Cross section, mm² 50 95 150 240 Characteristics Maximum DC resistance at 20 C, Ω / km 0,641 0,320 0,206 0,125 AC apparent resistance of the conductor at 90 C, Ω / km 0,820 0,410 0,270 0,160 Self-induction coefficient, mh / km (1) 0,500 0,450 0,400 0,370 Capacitance, µf / km 0,180 0,220 0,300 0,360 (1) Calculated for three bundled cables or three cables in a joined trefoil formation. For other sections, please contact us. Maximum allowable ampacity under continuous load Cross section, mm² Buried cables Winter Summmer 50 195 165 95 290 240 150 370 305 240 490 400. Ampacity is indicated in amps for a three-phase system without any thermal or electrical proximity under following thermal conditions: SUMMER: soil temperature : 20 C soil thermal resistivity : 1,2 K m / W WINTER: soil temperature : 10 C soil thermal resistivity : 0,85 K m / W For other sections, please contact us. Maximum allowable ampacity in the screen under short-circuit Cross Section, mm² Icc, A during 1 second 50 1250 95 2200 150 2500 240 2500 For other sections, please contact us. 9