BRÖCKSKES D-VIERSEN PV1-F 4,0 mm BRÖCKSKES D-VIERSEN PV1-F 4,0 mm d d 2 2 C VDE-REG.-Nr. 8292 10/2009



Similar documents
Festoon 715 P PUR cable for flexible application in festoon systems

CONTENT. Robot cables. page. < The company < W - worldwide < Certifications < Clientele / supplier numbers... 6

< SD 200 C TP Continuously flexible TPE/PUR paired data cable with coloured cores and overall copper screen... 10

CONTENT. Robot cables NEW. page. < The company < W - worldwide < Clientele / supplier numbers < Cables for dress package...

with coloured cores and overall copper screen UL/CSA... 17

ENERGY. TECSUN DUO (PV) Twin Cables for Photovoltaics

PROFIBUS cable. for PROFIBUS-PA and -DP 10/ EN

BETAtrans. Cables and Systems for Rolling Stock. Edition 2006

CABLES FOR PHOTOVOLTAIC SOLAR ENERGY INSTALLATIONS FOR CLEAN ENERGY

The Quality Connection. BETAflam Fire Resistant Safety Cables

ENERGY. TECWATER S1BN8-F 0,6/1 kv. Cable for Water Application

FLEXIBLE INDUSTRIAL CABLES H07RN-F TENAFLEX SR

VIPERFLEX ELECTRIC CABLE

Flexible Control Cables

Flexible cables for submersible products

Flygt flexible cables

Tri-Rated Flexible PVC Equipment Wire

DATA SHEET SERVO LK SMS FX8PLUS SIGNAL

COAX Cables Radio Frequency Cables

Series 8146/5-V37 and Series 8150/5-V37

Global cable expertise for rolling stock

RADOX railway cables acc. to EN and EN Edition 2009

CONFLEX ELECTRIC CABLE

Fire retardant IEC

VDE-approved PVC-Control Cables

Traveling Cable for Crane.

LEAD FREE FIREX. Interlock Armored Cables TECK90 and MC Industrial Cables. w w w. n e x a n s e n e r g y. c o m

PROFIBUS cable. PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications

Fire Resistant Cables

Allweather and Rubber Cables

Photo: HELUKABEL. Cables according to International Approvals N 1

5SV Residual Current Protective Devices

Building Cables and Wires

Cable Plug acc. to DIN EN , Form A

Power and Wiring Cables

VDE Information. Degree of Pollution, Clearances and Creepage Distances and Insulating Materials

Instrumentation Cable Power Cable Assembly Solutions...32

Gexol. Gexol. The Global Cable Solutions Company. Designed for safe, reliable performance in the harshest oil and gas operating environments

CABLE SPECIFICATION CAN CAB RJ45-SUBD9

MNS is Switchgear System Technical Overview

Generator DoCKInG StatIonS

Precision plays a pivotal role in your cable processing No insulation is too much for our stars Let s connect.

100% EMI Emission Containment

RoHS DATA, COAXIAL AND ELECTRONIC M.R. D A TA, C O A X I A L, ECOLGICAL Telecom Cables A N D EL E CTRON I C. Cables

Marine & Shipboard Cable JIS C 3410(1999) IEC , 353, 354, 376

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.:

We specialize in low voltage cables including: Stranded Single Cable H07V-R Flexible Single Cable H05V-K

ISO 9001 ISO CABLES AND WIRES CATALOGUE 2008

Communication, Signal & Data Cables

LIFE-LINE Safety Cables Continuous Bending Hi-Flex Electrical Cables to Guarantee Safe Cable & Hose Carrier Systems

The Quality Connection. Cable Solutions for Mobile Networks Business Unit Telecom

Chemical resistance Accidental

UGVCL/SP/591/11KV HT AB CABLE

2012 CATALOG AEROSPACE VVIRE & CABLE INC. aerospacewire.com

e-mobility Special cables for electric vehicles Coroplast Fritz Müller GmbH & Co. KG Tapes Cables Cable Assemblies

Coaxial cables? Video cables Loudspeaker cables

Cable Solutions for Servo and Variable Frequency Drives (VFD)

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

HARTING Ethernet Cabling 8-poles Overview

Tel.X Ni-Cd battery. The compact maintenance-free solution for telecom networks

Comprehensive safety concepts for building applications

CLI CableLine Laser-printed Identification Cable markers and wire markers. Product information

ETHERLINE Ethernet Cable, Connectors & Tools

Control cables CF880 PVC 12,5-5/ CF881 PVC 12,5-5/ CF890 igupur 12,5-20/ CF891 igupur 12,5-20/

Temperature Permissible ambient temperature. Weather Resistance to severe weather conditions. Impacts Cable mechanical resistance to impacts

CAVEL VS80205 MADE IN ITALY 1000 V

Supplementary instructions. Connection cable IP 66/IP 68 (1 bar) Retrofitting set/accessory for instruments of the plics family. Document ID: 34107

Specializing in the cable business for over 38 years, PT. SUPREME CABLE

Do s and don'ts of connection systems Are there any options when the clearance and creepage distances are not sufficient for UL 1059?

EE-SPY801/802. Photomicrosensors for detecting wafer-carrier mounting. Wafer-carrier Mounting Photomicrosensors. Ordering Information.

Powermate Range Pitch 7.62

Cable & Accessories for Wind Turbines

FIRE RESISTANT CABLE CONSTRUCTION OF CABLES

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

KNOW YOUR OPTIONS: 230 KV POWER CABLES

VOLTS - Copper conductor PVC insulated SSA 1320, IEC & BS 6004 HO 7V - U With Solid Conductor - TYPE IEC 01. Insulation Thickness

RF cables. Edition 2015

PCB transformers. Short circuit proof PCB transformer VB. General Data. Advantages. Applications. Circuit diagram. Standards & 1 Certifications W v

Type XHHW-2 or RHH/RHW-2/USE-2 GenFree II LSZH XLPO Single Conductor

Feed-through terminal block - SSK 110 KER-EX

Gulf Cable & Electrical Ind. Co.

The Quality Connection. BETAflam Safety cables for highest demands

XG2. Flat Cable Connectors for PCBs. Achieve Total Cost Reduction through High-density Mounting and Reduced Wiring. Terminal Arrangement

Spring Cage Feed-Through Terminal Blocks ST

Product and functional description

Servo Motor & Drive Cables

PC 4/ 5-STF-7,62. Extract from the online catalog. Order No.:

Section kv Power Cables

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

High Speed Cables for Enterprise Data Solutions Business Unit Telecommunication Systems

RELIABLE AND EFFICIENT MINING MINING CABLES

POWER ROCKER SWITCH UL, CSA, VDE, TÜV, ÖVE, KEMA, SEMKO, NEMKO, DEMKO, FIMKO, SEV UL, CSA, VDE, TÜV, SEMKO, NEMKO, DEMKO, FIMKO, SEV, KEMA, ÖVE

KNOW YOUR OPTIONS: 69 KV XLPE POWER CABLE

BETA Protecting SITOR Semiconductor Fuses

HARTING Ethernet Cabling 4-poles Overview

PC 4/ 4-ST-7,62. Extract from the online catalog. Order No.:

RAIL /// WIRE & CABLE WHERE THE BEST IDEAS IN RAIL BEGIN

Automotive Wire and Cable Products

Industrial Cable Solutions for Variable Frequency Drives

Transcription:

d BRÖCKSKES BRÖCKSKES D-VIERSEN D-VIERSEN PV1-F PV1-F 4,0 mm 4,0 2 mm VDE-REG.-Nr. 2 C 8292 10/2009

s - THE COMPANY DIN EN ISO 9001 More than 60 years of experience in temperature measurement and control technique as well as in cable production have made a one man business a company with nearly 500 staff members. Our strength is not only the production of standard products but also the development and manufacturing of special products acc. to customers specifications. Every year we manufacture more than 1500 special products on our customer s request. Every single product is a challenge for our technical team. We at B Bröckskes see ourselves as manufacturer and service provider - in the sense of real partnership and customer oriented work. The quality of our products is known in more than 40 countries of the world. Our customers have tested our products intensively and confirm that they have a longer service life than others. In all product ranges we are certified acc. to ISO 9001:2008. Besides we established an environmental management system for our company acc. to ISO 14001:2004, an occupational health and safety management acc. to NLF/ILO-OSH 2001 and OHSAS 18001:2007 as well as an energy management system acc. to DIN EN 16001:2009. And our future slogan is: We go forward! founded: CEO: 1947 by Peter Bröckskes sen. an independent, middle sized company Peter Bröckskes plant/location: in Viersen (lower Rhine) 110.000 m 2 company site manufacturing from copper conductor to outer sheath, own VDE proofed burnchamber and laboratory employees/workers: approx. 420 at the plant in Viersen, 500 worldwide yearly sales: approx. 95 Mio. worldwide products: Special Cables Temperature Measurement Cable Harnessing certificates and quality management system acc. to ISO 9001:2008 for every manufacturing field approvals: environmental management system acc. to ISO 14001:2004 occupational health and safety management acc. to NLF/ILO-OSH 2001 and OHSAS 18001:2007 energy management system acc. to DIN EN 16001:2009 MIL, VDE, HAR, IEC, GL, DNV, BV, KR, ABS, NK, RINA, LR, C 2

AREAS OF APPLICATION s ROBOT INDUSTRY RAILWAY MEDICAL TECHNOLOGY AUTOMATION TECHNOLOGY AUTOMOBILE INDUSTRY SOLAR STEEL INDUSTRY TECHNOLOGY ESCALATORS / ELEVATORS WIND HOT RUNNER POWER TECHNIQUE 3

B 110361971005 CABLES FOR PHOTOVOLTAIC SYSTEMS VDE-REG. no. 8292 halogen-free cable PV1-F for photovoltaic systems +120 C The requirements acc. to the VDE application prescriptions VDE-AR-E 2283-4 are fulfilled. PV1-F 4,0 mm 2 VDE-REG.-Nr. 8292 TÜVSüd-Bauart geprüft B 110361971005 Marking for PV1-F 71913386: SAB BRÖCKSKES D-VIERSEN PV1-F 4,0 mm 2 VDE-REG.-Nr. 8292 TÜVSüd-Bauart geprüft B 110361971005 C Construction: Conductor : tinned copper strands acc. to IEC 60228, EN 60228, VDE 0295, class 5 Primary insulation: primary insulation: Secondary insulation: secondary insulation: see table below see table below Outstanding features: fulfills the requirements acc. to the VDE application prescriptions VDE-AR-E 2283-4 halogen-free no flame propagation flame retardant and self-extinguishing up to +120 C weather resistant sunlight resistance with improved fire performance expected service life: up to 25 years resistance against acids and alkaline solutions ammonia resistance absence of marten attractants Nominal voltage Uo/U: Testing voltage: Min. bending radius Ø 12 mm: Ø > 12 mm: Temperature range Technical data: 0,6/1 kv (AC) 6500 V (AC) 3 x d 4 x d for ambient temperature: up to +90 C maximum temperature at the conductor: +120 C for installation: -30/+120 C fixed laying: -40/+120 C short circuit: +250 C VDE-REG.-no. 8292 as well as TÜV SÜD type tested B 110361971005: Halogen-free : without hydrogen chloride acc. to EN 50267-2-1, without fluorine content acc. to EN 60684-2 Corrosiveness of in compliance with IEC 60754-2 + conflagration gases: EN 50267-2-2 VDE + 0482 part 267-2-2 no development of corrosive conflagration gases Fire performance: flame retardant and self-extinguishing acc. to IEC 60332-1-2 +EN 60332-1-2 Sunlight resistance: Weather resistance: yes Ozone resistance: acc. to EN 50396 Ammonia resistance: Absence of harmful substances: acc. to RoHS directive of the European Union item no. nominal outer-ø copper cable cross-section max. figure weight mm 2 mm kg/km kg/km 7191.. 82 1,50 5,0 14,4 39 7191.. 84 2,50 5,4 24,0 50 7191.. 86 4,00 5,6 38,4 67 7191.. 87 6,00 6,2 57,6 95 7191.. 88 10,0 8,9 96,0 162 7191.. 89 16,0 10,3 153,6 234 7191.. 90 25,0 12,5 240,0 353 7191.. 91 35,0 13,9 236,0 463 Other dimensions are possible on request. Marking for primary insulation and secondary insulation Primary insulation / secondary insulation 33 black / black 38 black / red 32 black / blue 83 red / black 88 red / red 22 blue / blue 23 blue / black Other colours are possible on request. suitable for protecting class II 4 4

B 110361971005 CABLES FOR PHOTOVOLTAIC SYSTEMS halogen-free twin cable PV1-F dual for photovoltaic systems VDE-REG. no. 8292 +120 C The requirements acc. to the VDE application prescriptions VDE-AR-E 2283-4 are fulfilled. D-VIERSEN PV1-F 2x6,0 mm 2 VDE-REG.-Nr. 8292 TÜVSüd-Bauart geprüft B 1 Construction: Conductor : tinned copper strands acc. to IEC 60228, EN 60228, VDE 0295, class 5 Primary insulation: primary insulation: Secondary insulation: secondary insulation: black / red or black / blue black Outstanding features: fulfills the requirements acc. to the VDE application prescriptions VDE-AR-E 2283-4 halogen-free no flame propagation flame retardant and self-extinguishing up to +120 C weather resistant sunlight resistance with improved fire performance expected service life: up to 25 years resistance against acids and alkaline solutions ammonia resistance SAB BRÖCKSKES D-VIERSEN absence of marten attractants Marking for PV1-F dual 71918317: PV1-F 2x6,0 mm 2 VDE-REG.-Nr. 8292 TÜVSüd-Bauart geprüft B 110361971005 C Nominal voltage Uo/U: Testing voltage: Min. bending radius Ø 12 mm: Ø > 12 mm: Temperature range Technical data: 0,6/1 kv (AC) 6500 V (AC) 3 x d 4 x d for ambient temperature: up to +90 C maximum temperature at the conductor: +120 C for installation: -30/+120 C fixed laying: -40/+120 C short circuit: +250 C VDE-REG.-no. 8292 as well as TÜV SÜD type tested B 110361971005: Halogen-free : without hydrogen chloride acc. to EN 50267-2-1, without fluorine content acc. to EN 60684-2 Corrosiveness of in compliance with IEC 60754-2 + conflagration gases: EN 50267-2-2 VDE + 0482 part 267-2-2 no development of corrosive conflagration gases Fire performance: flame retardant and self-extinguishing acc. to IEC 60332-1-2 +EN 60332-1-2 Sunlight resistance: Weather resistance: yes Ozone resistance: acc. to EN 50396 Ammonia resistance: Absence of harmful substances: acc. to RoHS directive of the European Union item no. no. of nominal outer-ø copper cable conductors cross-section approx. figure weight mm 2 mm kg/km kg/km 7191.. 16 2 4,00 6,0 x 11,9 76,8 140 7191.. 17 2 6,00 6,9 x 13,8 115,2 190 7191.. 18 2 10,0 8,7 x 17,4 192,0 323 Other dimensions are possible on request. Marking for primary insulation and secondary insulation Primary insulation / secondary insulation 83 red / black 23 blue / black Other colours are possible on request. suitable for protecting class II 4 5

CABLES FOR PHOTOVOLTAIC SYSTEMS PV Wire halogen-free cable for photovoltaic systems Photovoltaic Wire Service- Entrance Cable sunlight-resistant -40 C ( U L) Service-Entrance Cable Type USE-2 600V Single Conductor C Marking for PV Wire 71813386: SAB BRÖCKSKES D-VIERSEN 12 AWG ( U L) Photovoltaic Wire 600V 90 C dry 90 C wet sunlight-resistant -40 C ( U L) Service-Entrance Cable Type USE-2 600V Single Conductor C Construction: Conductor : tinned copper strands acc. to IEC 60228, EN 60228, VDE 0295, class 5 and UL standard 758 table 5.1 + UL 1581 table 20.1 Primary insulation: A 285 primary insulation: see table below Secondary insulation: A 285 secondary insulation: see table below Outstanding features: UL Subject 4703 PV Wire UL 854 USE-2 halogen-free flame retardant and self-extinguishing weather resistant sunlight resistance resistance against acids and alkaline solutions connection cable for photovoltaic modules acc. to NEC Section 690.31 (A) ammonia resistance absence of marten attractants Nominal voltage: Technical data: 600 V (AC) Testing voltage: 3000 V (AC) Min. bending radius Ø 12 mm: 3 x d Ø > 12 mm: 4 x d Temperature range for ambient temperature: -40 C/+90 C Halogen-free : without hydrogen chloride acc. to EN 50267-2-1, without fluorine content acc. to EN 60684-2 Corrosiveness of in compliance with IEC 60754-2 + conflagration gases: EN 50267-2-2 VDE + 0482 part 267-2-2 no development of corrosive conflagration gases. Fire performance: flame retardant and self-extinguishing acc. to IEC 60332-1-2 +EN 60332-1-2 and (UL) FT1 Sunlight resistance: yes Weather resistance: Ozone resistance: acc. to EN 50396 Ammonia resistance: Absence of harmful substances: acc. to RoHS directive of the European Union item no. AWG outer-ø copper cable max. figure weight mm kg/km kg/km 7181.. 86 12 6,6 38,4 77 7181.. 87 10 7,1 57,6 97 7181.. 88 8 8,9 84,5 151 Other dimensions are possible on request. Marking for primary insulation and secondary insulation Primary insulation / secondary insulation 33 black / black 23 blue / black 63 white / black 83 red / black Other colours for the primary insulation possible on request. 6

B 110361971005 +120 C CABLES FOR PHOTOVOLTAIC SYSTEMS VDE-REG. no. 8292 Construction: PV1-F halogen-free cable for photovoltaic systems with UL The requirements acc. to the VDE application prescriptions VDE-AR-E 2283-4 are fulfilled. 90 C wet sunlight-resistant -40 C ( U L) Service-Entrance Cable Type USE-2 600V Single Condu Technical data: Photovoltaic Wire Service- Entrance Cable Marking for PV1-F with UL 71913346: SAB BRÖCKSKES D-VIERSEN PV1-F 4,0 mm 2 VDE-REG.-Nr. 8292 TÜVSüd-Bauart geprüft B 110361971005 AWG12 (UL) Photovoltaic Wire 600V 90 C dry 90 C wet sunlight-resistant -40 C ( U L) Service-Entrance Cable Type USE-2 600V Single Conductor C Conductor : tinned copper strands acc. to IEC 60228, EN 60228, VDE 0295, class 5 and UL standard 758 table 5.1 + UL 1581 table 20.1 Primary insulation: primary insulation: see table below Secondary insulation: secondary insulation: see table below Outstanding features: fulfills the requirements acc. to the VDE application prescriptions VDE-AR-E 2283-4 UL Subject 4703 PV Wire UL 854 USE-2 halogen-free no flame propagation flame retardant and self-extinguishing up to +120 C weather resistant sunlight resistance with improved fire performance expected service life: up to 25 years resistance against acids and alkaline solutions connection cable for photovoltaic modules acc. to NEC Section 690.31 (A) ammonia resistance absence of marten attractants item no. nominal outer-ø copper cable cross-section mm figure weight mm 2 kg/km kg/km 7191.. 46 4,00 6,8 38,4 79 7191.. 47 6,00 7,5 57,6 114 Nominal voltage Uo/U: 0,6/1 kv (AC) (UL): 600 V (AC) Testing voltage: 6500 V (AC) (UL): 3000 V (AC) Min. bending radius Ø 12 mm: 3 x d Ø > 12 mm: 4 x d Temperature range VDE-REG.-no. 8292 as well as TÜV SÜD type tested B 110361971005: for ambient temperature: up to +90 C (UL): -40 C/+90 C maximum temperature at the conductor: +120 C for installation: -30/+120 C fixed laying: -40/+120 C short circuit: +250 C Halogen-free : without hydrogen chloride acc. to EN 50267-2-1, without fluorine content acc. to EN 60684-2 Corrosiveness of in compliance with IEC 60754-2 + conflagration gases: EN 50267-2-2 VDE + 0482 part 267-2-2 no development of corrosive conflagration gases Fire performance: flame retardant and self-extinguishing acc. to IEC 60332-1-2 +EN 60332-1-2 and (UL) FT1 Sunlight resistance: yes Weather resistance: Ozone resistance: acc. to EN 50396 Ammonia resistance: Absence of harmful substances: acc. to RoHS directive of the European Union Marking for primary insulation and secondary insulation Primary insulation / secondary insulation 33 black / black 83 red / black 23 blue / black 63 white / black Other colours are possible on request. Other dimensions are possible on request. suitable for protecting class II 4 7

PRODUCT RANGE FLEXIBLE CABLES Halogen-free cables Cable track cables Servo motor cables ETFE, FEP, PFA cables Bus cables Torsion cables Hybrid and special cables Control and connection cables Data cables Besilen (Silicone) cables Compensating and extension cables Tray cables TEMPERATURE MEASUREMENT Protecting armatures and gauge slides Mineral insulated thermocouples and Mineral insulated resistance thermometers Temperature measurement in plastic processing industry/hot runner technique Diesel thermocouples Probe with stainless steel sleeve Temperature measurement in test vehicles Measurement techniques CABLE HARNESSING Harnessed cables acc. to customer s specification Harnessed cable track cables Helix cables Cable harnesses Harnessed motor and transmission cables for Siemens and Indramat drives 8 S Bröckskes GmbH & Co. KG Grefrather Str. 204-212 b 41749 Viersen GERMANY Tel.: +49/2162/898-0 Fax: +49/2162/898-101 www.sab-worldwide.com info@sab-broeckskes.de 03/2012