BETA Protecting SITOR Semiconductor Fuses
|
|
- Junior Austin
- 7 years ago
- Views:
Transcription
1 BETA Protecting SITOR Semiconductor Fuses /2 Product overview /3 /17 SITOR, cylindrical fuse design /22 SILIZED, NEOZED and DIAZED design Siemens ET B1 /2008
2 Product overview Overview Devices Page Field of application Standards Used in /3 Fuse links in LV HRC design and a huge variety of models support a wide range of applications from 500 V to 1500 V and 150 A to 1250 A. Fuses with slotted blade contacts, bolt-on links or female thread and special designs. Non-residential buildings Residential buildings Industry SITOR, cylindrical fuse design /17 Fuse links, fuse holders can be used as fuse switch disconnectors and fuse bases to 00/90 V AC and 00/700 V DC from 1 to 0 A in sizes 38 mm, 1 51 mm and mm SILIZED, NEOZED and DIAZED design /22 NEOZED fuse links for 00 V AC and 250 V DC and DIAZED for 500 V AC and 500 V DC /2 Siemens ET B1 /2008
3 BETA Protecting Overview SITOR fuses protect power semiconductors from the effects of a short circuit because the super-quick disconnect characteristic is far quicker than that of conventional LV HRC fuses. They protect expensive devices and system components such as converters with fuses in the input and in the DC link, UPS systems and soft starters for motors. Panel mounting requirements have given rise to various connection versions and designs. The fuses with blade contacts comply with IEC and are suitable for installation in LV HRC fuse bases, in LV HRC switch disconnectors and in switch disconnectors with fuses. They also include fuses with slotted blade contacts for screw fixing with 1 mm mounting dimension, whose sizes comply with IEC Fuses with slotted blade contacts for screw fixing with 80 mm or 1 mm mounting dimension are often screwed directly onto busbars for optimum heat dissipation. Even better heat transmission is provided by the compact fuses with M or M12 female thread, which are also mounted directly onto busbars. Bolt-on links with 80 mm mounting dimension are another panel-mounting version for direct busbar mounting. The fuses for SITOR thyristor sets, railway rectifiers or electrolysis systems were developed specially for these applications. To find out which LV HRC fuse bases and safety switching devices can be used with the SITOR fuses, please refer to the chapter "Low-voltage fuse systems". The characteristic curves for the configuration and assignment of SITOR fuses to fuse bases and 3NP and 3KL safety switching devices can be found in the Catalog ET B1 Add-On Characteristic Curves and on the Internet. The new size 3 type ranges have a round ceramic body instead of a square one. Key features of these type ranges are small I²t values with low power dissipation and a high alternating load capability. The dimensions and the functional dimensions comply with the current standards IEC 029-/EN 029- (VDE 03-). Note: The ordering data of the fuses are listed in ascending order of the rated voltage in the selection tables. Benefits SITOR fuses have a high varying load factor, which ensures a high level of operating safety and plant availability even when subject to constant load change. The use of SITOR fuses in LV HRC bases or Siemens switch disconnectors has been tested with regard to heat dissipation and maximum current loading. This makes planning and dimensioning easier and prevents consequential damage. Our high standard of quality ensures good compliance with the characteristic curve and accuracy. This ensures long-term protection of devices. Operational classes Fuses are categorized according to function and operational classes. SITOR semiconductor fuses, in LV HRC design, are available in the following operational classes: ar: for the short-circuit protection of power semiconductors (partial range protection) gr: for the protection of power semiconductors (full range protection) gs: The gs operational class combines cable and line protection with semiconductor protection (full range protection). Siemens ET B1 /2008 /3
4 Selection and ordering data Size I e U e Operational classes Breaking I 2 t value Power loss Varying load factor DT Order No. Price PG PU PS*/ P. unit Weight approx. A VAC A 2 s W WL Unit(s) Unit(s) kg With slotted blade contacts for M screw fixing, mounting dimension: 1 mm, or for installation in LV HRC fuse bases or switch disconnectors gr B 3NC2 23-3C B 3NC2 25-3C B 3NC2 27-3C B 3NC2 28-3C ar B 3NC2 31-3C B 3NC2 32-3C With slotted blade contacts with two M oblong slots, or for installation in LV HRC fuse bases or switch disconnectors gr D 3NC2 23-0C D 3NC2 25-0C D 3NC2 27-0C D 3NC2 28-0C ar C 3NC2 31-0C D 3NC2 32-0C With blade contacts for mounting in LV HRC fuse bases or switch disconnectors gr D 3NE B 3NE With slotted blade contacts for M screw fixing, mounting dimension: 1 mm, or for installation in LV HRC fuse bases or switch disconnectors gr B 3NC8 23-3C B 3NC8 25-3C B 3NC8 27-3C B 3NC8 31-3C B 3NC8 3-3C ar C 3NC8-3C N With slotted blade contacts for M screw fixing, mounting dimension: 1 mm, or for installation in LV HRC fuse bases or switch disconnectors gr B 3NE B 3NE B 3NE B 3NE N With slotted blade contacts for M screw fixing, mounting dimension: 1 mm, or for installation in LV HRC fuse bases or switch disconnectors gr B 3NE B 3NE B 3NE B 3NE / Siemens ET B1 /2008 * You can order this quantity or a multiple thereof.
5 BETA Protecting Size I e U e Operational classes Breaking I 2 t value Power loss Varying load factor DT Order No. Price PG PU PS*/ P. unit Weight approx. A VAC A 2 s W WL Unit(s) Unit(s) kg With slotted blade contacts for M12 screw fixing, mounting dimension: 1 mm, or for installation in LV HRC N fuse bases or switch disconnectors gr B 3NE B 3NE B 3NE B 3NE B 3NE B 3NE With slotted blade contacts with 2 M oblong slots for screw fixing, or for installation in LV HRC fuse bases or switch disconnectors gr B 3NC8 23-0C B 3NC8 25-0C B 3NC8 27-0C B 3NC8 31-0C B 3NC8 3-0C Size I e U e Operational classes A VAC/ V DC Breaking I 2 t value Power loss Varying load factor DT Order No. Price PG PU PS*/ P. unit A 2 s W WL Unit(s) Unit(s) kg Weight approx. With M8 bolt-on links, mounting dimension: 80 mm, for screwing onto busbars / gr B 3NE B 3NE A 3NE A 3NE A 3NE ar A 3NE } 3NE } 3NE } 3NE } 3NE } 3NE } 3NE } 3NE * You can order this quantity or a multiple thereof. Siemens ET B1 /2008 /5
6 Size I e U e Operational classes Breaking I 2 t value Power loss Varying load factor DT Order No. Price PG PU PS*/ P. unit Weight approx. A VAC A 2 s W WL Unit(s) Unit(s) kg With blade contacts for mounting in LV HRC fuse bases or switch disconnectors gs } 3NE } 3NE } 3NE } 3NE } 3NE } 3NE } 3NE } 3NE gs } 3NE } 3NE gs } 3NE } 3NE } 3NE A 3NE gs } 3NE } 3NE A 3NE A 3NE gs A 3NE A 3NE A 3NE A 3NE gr A 3NE A 3NE A 3NE gr A 3NE A 3NE A 3NE A 3NE gr A 3NE B 3NE A 3NE A 3NE gr A 3NE A 3NE A 3NE B 3NE A 3NE A 3NE / Siemens ET B1 /2008 * You can order this quantity or a multiple thereof.
7 BETA Protecting Size I e U e Operational classes Breaking I 2 t value Power loss Varying load factor DT Order No. Price PG PU PS*/ P. unit Weight approx. A VAC A 2 s W WL Unit(s) Unit(s) kg With blade contacts for mounting in LV HRC fuse bases or switch disconnectors (contd.) gr } 3NE } 3NE } 3NE } 3NE ar } 3NE } 3NE } 3NE } 3NE With slotted blade contacts for M12 screw fixing, mounting dimension: 80 mm ar C 3NC D 3NC C 3NC D 3NC C 3NC D 3NC C 3NC D 3NC D 3NC With M12 female thread at both ends for direct busbar mounting ar C 3NC D 3NC C 3NC D 3NC C 3NC D 3NC C 3NC C 3NC C 3NC With slotted blade contacts for M screw fixing, mounting dimension: 1 mm, or for installation in LV HRC fuse bases or switch disconnectors ar } 3NE 327-0B } 3NE 330-0B } 3NE 333-0B } 3NE 33-0B } 3NE With blade contacts for mounting in LV HRC fuse bases or switch disconnectors gr } 3NE } 3NE } 3NE ar } 3NE } 3NE } 3NE } 3NE } 3NE * You can order this quantity or a multiple thereof. Siemens ET B1 /2008 /7
8 Size I e U e Operational classes Breaking I 2 t value Power loss Varying load factor DT Order No. Price PG PU PS*/ P. unit Weight approx. A VAC A 2 s W WL Unit(s) Unit(s) kg With slotted blade contacts for M screw fixing, mounting dimension: 1 mm, or for installation in LV HRC fuse bases or switch disconnectors ar A 3NE A 3NE } 3NE } 3NE } 3NE } 3NE B A 3NE A 3NE B } 3NE ar A 3NE B A 3NE } 3NE3 33-0B } 3NE } 3NE ar } 3NE } 3NE } 3NE With slotted blade contacts for M screw fixing, mounting dimension: 130 mm ar D 3NE3 21-0C B 3NE3 2-0C B 3NE3 30-0C B 3NE3 32-0C B 3NE3 35-0C B 3NE3 3-0C D 3NE3 3-0C D 3NE3 37-0C With M female thread at both ends for direct mounting on busbars ar D 3NE With slotted blade contacts for M12 screw fixing, mounting dimension: mm ar D 3NE3 37-1C With slotted blade contacts for M12 screw fixing, mounting dimension: 1 mm, or for installation in LV HRC fuse bases or switch disconnectors ar C 3NC D 3NC C 3NC D 3NC C 3NC D 3NC D 3NC /8 Siemens ET B1 /2008 * You can order this quantity or a multiple thereof.
9 BETA Protecting Size I e U e Operational classes Breaking I 2 t value Power loss Varying load factor DT Order No. Price PG PU PS*/ P. unit Weight approx. A VAC A 2 s W WL Unit(s) Unit(s) kg With M12 female thread at both ends for direct busbar mounting ar C 3NC D 3NC C 3NC D 3NC C 3NC D 3NC C 3NC With slotted blade contacts for M12 screw fixing, mounting dimension: 1 mm N ar B 3NC B 3NC B 3NC B 3NC B 3NC N With M12 female thread at both ends for direct busbar mounting ar B 3NC B 3NC B 3NC B 3NC B 3NC With slotted blade contacts for M screw fixing, mounting dimension: 2 mm ar D 3NE5 2-0C C 3NE5 2-0C D 3NE5 30-0C D 3NE5 31-0C D 3NE5 33-0C D 3NE5 33-1C With slotted blade contacts for M screw fixing, mounting dimension: 170 mm ar D 3NE5 27-0C B 3NE5 33-0C D 3NE5 3-0C With slotted blade contacts for M screw fixing, mounting dimension: 2 mm ar D 3NE7 25-0C D 3NE7 27-0C D 3NE7 31-0C D 3NE7 32-0C D 3NE7 33-0C D 3NE7 3-0C With slotted blade contacts for M12 screw fixing, mounting dimension: 2 mm ar C 3NE7 33-1C D 3NE7 8-1C C 3NE7 3-1C B 3NE7 37-1C * You can order this quantity or a multiple thereof. Siemens ET B1 /2008 /9
10 Size I e U e Operational classes Breaking I 2 t value Power loss Varying load factor DT Order No. Price PG PU PS*/ P. unit Weight approx. A VAC A 2 s W WL Unit(s) Unit(s) kg With slotted blade contacts for M12 screw fixing, mounting dimension: 20 mm ar D 3NE9 32-1C D 3NE9 3-1C D 3NE9 3-1C Fuses for special applications For screwing onto water-cooled busbars, for rectifiers in electrolysis systems -- 1) ar X 3NC D 3NC C 3NC D 3NC D 3NE D 3NE With M female thread at both ends for direct mounting on busbars, for air-cooled rectifiers in electrolysis systems -- 1) gr D 3NE D 3NE ar C 3NE D 3NE Fuses with installation holder for SITOR QG thyristor sets ar D 3NE D 3NE Fuses with installation holder for SITOR QG11 thyristor sets -- 1) gr C 3NE ar B 3NE ar B 3NE Fuses female thread at both ends for SITOR QG12 thyristor sets -- 1) ar } 3NE 327-B } 3NE 330-B } 3NE 333-B } 3NE 33-B } 3NE With M12 female thread at both ends for direct mounting on busbars for railway supply rectifiers -- 1) ar D 3NC D 3NC ) Special design. / Siemens ET B1 /2008 * You can order this quantity or a multiple thereof.
11 Dimensional drawings ,5 1 71, ,5 Ø75 59, I2_13719a 17, 11,5 Ø75 59, , I2_13721a 17, 19 3NC2..-0C, 3NC8..-0C 3NC2..-3C, 3NC8..-3C 8 2, f 8 2, I2_ c 12,512,5,5 b 73,5 a 0, 82,1 I2_0717 3NE1 3.-0, 3NE NE NE , 3NE , 82,1 70 Type I2_073b d f g e Dimensions (mm) a b c d e f g 3NE NE Siemens ET B1 /2008 /11
12 I2_ I2_ ,5 I2_ , ,3 2,3 20 0,5 35,8 53,3 53,8 79,9 21 9, 2,2 8 35, NE NE NE , 3NE , 3NE , ,5 3, I2_0715,5 3 $! 25 7, I2_ $ & # %! $ " & %! %! # 1 " % 3NE , 3NE NE , 3NE NE1..-2 /12 Siemens ET B1 /2008
13 32,2 Ø75 Ø30 0,7 2 d 1 13 b c a I2_139 b a M12 13 Ø75 I2_1370 2, ,5 19 3NC , 3NC NC3 2..-, 3NC Type Dimensions (mm) Type Dimensions (mm) a b c d a b 3NC NC NC NC ,5 11,5 1,5 12,5 73,5 f,5 11,5 8 2, ,512,5 73,5 a I2_050a b c,5 11,5 1,5 12, ,5 0 I2_073b d f g e I2_ NE 3..-0B, 3NE 337 3NE 1.. 3NE3 22., 3NE3 23., 3NE3 3.. Type Dimensions (mm) a b c d e f g 3NE NE NE Siemens ET B1 /2008 /13
14 32 32,2 Ø75 Ø30 0,7 a 2 d 1 13 b c a I2_139 b a 81 91,5 129 b M12 13 Ø75 I2_1370 a Ø75 I2_13722a 2, , 17, 19 17,5 19 3NE3...-0C, 3NE3..-1C 3NC NC3..- Type Dimensions (mm) Type Dimensions (mm) Type Dimensions (mm) a b a b c d a b 3NE3...-0C NC NC NE3..-1C Ø28 M 70 I2_1130a ,5 9 3NE3 35- /1 Siemens ET B1 /2008
15 BETA Protecting e a ,5 219, , c d b a e Ø75 I2_ , 17, 9 a Ø75 59, I2_1372a 17, 13 Ø75 I2_13725a , 17, 19 3NE5..-0C 3NE5..-0C, 3NE5..-1C; 3NE7...-0C, 3NE7...-1C 3NE9..-1C Type Dimensions (mm) Type Dimensions (mm) a b c d e a 3NE5..-0C NE5..-0C NE5..-1C 13 3NE7...-0C NE7...-1C 13 Siemens ET B1 /2008 /15
16 I2_1139a Ø50 Ø28 Ø50 M M 9 2,5 0,3 SW I2_11370a Ø73 M2 Ø0 M M SW1 b a c I2_11372a Ø11 Ø M 75, ,5 I2_11371a Ø28 70 M 70 b 81,5 a 3NC NC NE..-7, 3NE NE.., 3NE9.. Type Dimensions (mm) a b c 3NC NC NC Type Dimensions (mm) a b 3NE NE NE NE 99 8 Ø20 M, Ø20 M 55 77, ,5 73 I2_11373a I2_11375a I2_1137a , ,5, I2_1137a NE NE NE 3..-B, 3NE 337-3NC /1 Siemens ET B1 /2008
17 BETA Protecting SITOR, cylindrical fuse design Overview SITOR cylindrical fuses protect power semiconductors against the effects of short circuits because the super quick disconnect characteristic is far quicker than that of conventional fuses. They protect expensive devices and system components such as semiconductor contactors, electronic relays (solid state), converters with fuses in the input and in the DC link, UPS systems and soft starters for motors up to 0 A. The cylindrical design is approved for industrial applications. The cylindrical fuse links comply with IEC 029. Cylindrical fuse holders also comply with IEC 029 and UL 512. The cylindrical fuse holders for x 38 mm and 1 x 51 mm have been tested and approved as fuse switch disconnectors and the cylindrical fuse holders for 22 x 58 mm as fuse disconnectors according to the switching device standard IEC The utilization category and the tested current and voltage values are specified in the Table "Technical Specifications". The cylindrical fuse holders have been specially developed for the application of SITOR fuse links with regard to heat tolerance and heat dissipation and are therefore not recommended for standard applications. Cylindrical fuse bases do not offer the same comprehensive touch protection as the fuse holders, but have better heat dissipation. The single-pole cylindrical fuse bases for 1 x 51 mm and 22 x 58 mm allow modular expansion to multipole bases. Benefits Cylindrical fuses have an extremely compact design and a correspondingly small footprint. The cylindrical fuses have IEC and UL approval and are suitable for universal use worldwide. The use of SITOR cylindrical fuses in the cylindrical fuse holders and bases has been tested with regard to heat dissipation and maximum current loading. This makes planning and dimensioning easier and prevents consequential damage. The use of fuse holders as switch disconnectors expands the area of application of these devices and increases operating safety. Technical specifications Sizes mm mm Cylindrical fuse links 3NC1 0, 3NC1, 3NC2 2 Standards IEC 029-; UL 28-13; CSA C22.2 No Approved acc. to UL 28-13; UL File No. E17357; CSA C22.2 No Fuse holders, fuse bases 3NC1, 3NC2 Standards IEC 029-2; EN 097-3;UL 512; CSA C22.2 No. 39-M Approved acc. to UL 512; UL File No. E22003; CSA C22.2 No. 39-M Rated voltage VAC 90 Rated current I n A Max. power dissipation of fuse links (conductor cross-section used) W 3 ( mm 2 ).3 ( mm 2 ) 5 ( mm 2 ).5 (25 mm 2 ) 9.5 (35 mm 2 ) 11 (50 mm 2 ) Feeder terminals mm Conductor cross-sections Solid and stranded mm AWG Conductor cross-section, solid and stranded AWG /0 Utilization category Acc. to AC 22B/32 A/00 V AC 22B/50 A/00 V AC 20B/90 V IEC AC 22B/ A/90 V AC 22B/20 A/90 V Rated conditional short-circuit current At 00V ka 50 (32 A gg) 0 (50 A gg) 0 (0 A gg) 80 (80 A gg) Siemens ET B1 /2008 /17
18 SITOR, cylindrical fuse design Selection and ordering data Size I e U e Breaking I 2 t value Power loss DT Order No. Price PG PU PS*/ P. unit Weight approx. mm mm A V AC/ A 2 s W Unit(s) Unit(s) kg V DC Cylindrical fuse links, operational class ar / A 3NC } 3NC B 3NC } 3NC B 3NC } 3NC } 3NC } 3NC } 3NC / B 3NC } 3NC B 3NC } 3NC / B 3NC } 3NC } 3NC } 3NC } 3NC } 3NC B 3NC } 3NC } 3NC } 3NC / B 3NC B 3NC B 3NC B 3NC } 3NC } 3NC } 3NC / } 3NC Cylindrical fuse links with striking pin, operational class ar / B 3NC B 3NC B 3NC C 3NC C 3NC B 3NC B 3NC B 3NC / C 3NC C 3NC B 3NC B 3NC B 3NC B 3NC B 3NC / B 3NC / Siemens ET B1 /2008 * You can order this quantity or a multiple thereof.
19 BETA Protecting SITOR, cylindrical fuse design Size Version Rated voltage DT Order No. Price PG PU PS*/ P. unit mm mm V AC Unit(s) Unit(s) kg Cylindrical fuse holders Can be used as fuse switch disconnectors 1) Weight approx. 38 1P 90 } 3NC P } 3NC P } 3NC P } 3NC P } 3NC P B 3NC P } 3NC P } 3NC P B 3NC Cylindrical fuse holders Can be used as fuse switch disconnectors, with alarm switches for fuse links with striking pin 1) P 90 B 3NC P B 3NC Cylindrical fuse bases 38 1P 00 B 3NC P C 3NC P B 3NC P 90 B 3NC P B 3NC Cylindrical fuse clips For fuses 38 C 3NC For fuses 1 51 B 3NC Fuse tongs 38, 1 51, B 3NC ) Please observe the utilization category and current/voltage values specified in the "Technical specifications" table. Dimensional drawings Cylindrical fuse links I2_11377 Ø,2 1,3 9, NC NC1.. 3NC2 2.. I2_11379 I2_11380 Ø 22,2 * You can order this quantity or a multiple thereof. Siemens ET B1 /2008 /19
20 SITOR, cylindrical fuse design Cylindrical fuse holders I2_11382a NC I2_11383a NC I2_1138a NC1 29. Cylindrical fuse holders with alarm switch I2_ I2_ NC NC /20 Siemens ET B1 /2008
21 BETA Protecting SITOR, cylindrical fuse design Cylindrical fuse bases 21, ,5 2 3NC to 3NC ,5 7 I2_1138a I2_11385a 2 3NC ,5 1,8 12,5 I2_ NC ,2,5 Siemens ET B1 /2008 /21
22 SILIZED, NEOZED and DIAZED design Overview SILIZED is the brand name of the NEOZED fuses (D0 fuses) and the DIAZED fuses (D fuses) with super quick characteristic for semiconductor protection. The fuses are used together with fuse bases, fuse screw caps and accessories of the standard fuse system. SILIZED fuses protect power semiconductors from the effects of short circuits because the super quick disconnect characteristic is far quicker than that of conventional fuses. They protect expensive devices and system components such as semiconductor contactors, static relays, converters with fuses in the input and in the DC link, UPS systems and soft starters for motors up to 0 A. If using fuse bases and fuse screw caps made of molded plastic, always take into account the maximum permissible values of power loss due to the high power dissipation (power loss) of the SILIZED fuses. If using these components, the following maximum permissible power losses apply: NEOZED D02: 5.5 W DIAZED DII:.5 W DIAZED DIII: 7.0 W. For this reason, in some cases, a thermal permanent load of only 50 % is possible. The DIAZED screw adapter DII for 25 A is used for the 30 A fuse link. Benefits SILIZED fuses have an extremely compact design. This means they have a very small footprint particularly the NEOZED version. The rugged and well-known DIAZED design complies with IEC It is globally renowned and can be used in many countries. A huge range of fuse bases and accessories are available for the NEOZED and DIAZED versions of the SILIZED fuses. This increases the application options in many devices. Technical specifications SILIZED fuse links, NEOZED design 5SE1 3 Standards DIN VDE 03-3; IEC 029-3; DIN VDE 03-; IEC 029- Operational class gr Characteristic Super quick Selection and ordering data SILIZED fuse links, DIAZED design 5SD Rated voltage U n VAC VDC Rated current I n A Rated breaking capacity ka AC 50 ka DC 8 Mounting position Any, but preferably vertical Non-interchangeability Using adapter sleeves Using screw adapter or adapter sleeves Resistance to climate C Up to 5 at 95 % rel. humidity Ambient temperature C , humidity 90 % at 20 Size I e U e Breaking I 2 t value A VAC/ V DC SILIZED fuse links, NEOZED design Operational class gr Power loss DT Order No. Price PG PU PS*/ P. unit A 2 s W Unit(s) Unit(s) kg Weight approx. D01 00/ B 5SE B 5SE D B 5SE B 5SE B 5SE B 5SE B 5SE /22 Siemens ET B1 /2008 * You can order this quantity or a multiple thereof.
23 BETA Protecting SILIZED, NEOZED and DIAZED design Size I e U e Breaking I 2 t value A VAC/ V DC SILIZED fuse links, DIAZED design Operational class gr Power loss DT Order No. Price PG PU PS*/ P. unit A 2 s W Unit(s) Unit(s) kg Weight approx. DII 1 500/ A 5SD A 5SD A 5SD A 5SD DIII A 5SD A 5SD A 5SD DIV B 5SD B 5SD Dimensional drawings 5SE1 Size D01 D02 I2_0252d h Ød Rated current in A Dimension d Dimension h 3 3 5SD 20, 5SD 30, 5SD 0, 5SD 80 Size/thread DII/E27 I2_027b Ød Ø22,5 9 Rated current in A Dimension d SD 50, 5SD 0, 5SD 70 Size/thread DIII/E33 I2_028b Ød Ø28 Rated current in A Dimension d SD5, 5SD5 20 Size/thread DIV/R1¼" Ød I2_082a Rated current in A 80 0 Dimension d 5 7 Ø3,5 57 * You can order this quantity or a multiple thereof. Siemens ET B1 /2008 /23
24 Notes /2 Siemens ET B1 /2008
5SV Residual Current Protective Devices
s Siemens AG 2013 SENTRON 5SV Residual Current Protective Devices New portfolio for reliable personnel, material and fire protection Safe protection against residual currents Residual current protective
More informationRelés e Contatores de Estado Sólido SIRIUS
Relés e Contatores de Estado Sólido SIRIUS Coletânea de dados técnicos ( product data sheet ) Agosto/212 SSR - 3RF21 22,5 mm Ponto Zero SSR - 3RF2 45 mm Ponto Zero SSR - 3RF22 45 mm Ponto Zero Trifásico
More informationBETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview
BETA Switching Siemens AG 200 5TT5 Insta contactors, AC technology Overview The 5TT5 Insta contactors are equipped with an AC magnetic system and are ideal for use under harsh conditions. The auxiliary
More information3K Load-Break Switches The Program for Safety and Performance. sentric
3K Load-Break Switches The Program for Safety and Performance sentric Whether for reliable switching and isolation under load, or for protection against overload or short-circuits our 3K range of load-break
More informationSwitching Devices Contactors and Contactor Assemblies Special Applications
Switching Devices Contactors and Contactor Assemblies Special Applications Price groups PG 1B, 1H /2 Introduction Contactors for special applications / SIRIUS 3RT1 contactors for resistive loads (AC-1),
More informationSeries 8146/5-V37 and Series 8150/5-V37
www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection
More informationSwitching Devices. 8/2 Introduction. 8/5 5TE8 control switches. 8/8 5TE4 pushbuttons. 8/11 5TE5 light indicators. 8/13 5TE On/Off switches
Siemens AG 2014 Switching Devices /2 Introduction /5 5TE control switches / 5TE4 pushbuttons /11 5TE5 light indicators /13 5TE On/Off switches /20 5TE DC isolators /22 5ST busbars for modular installation
More informationCurrent transformers (CT) & Shunts
Current transformers (CT) & Shunts Genreal overview LV CURRENT TRANSFORMERS Product selection guide Standard industrial transformers?????? TCR - TCRO range NEW 9 9 9 Current summation JVM 0 9 TCR usbar
More informationIEC 60269 gg & am STANDARD LOW VOLTAGE FUSE
IEC 60269 gg & am STANDARD LOW VOLTAGE FUSE. INTRODUCTION 2. INTRODUCTION TO THE IEC 60269 STANDARD 3. COMPARISON OF THE TIME CURRENT CURVES OF DIFFERENT FUSE TYPES 3.. Comparison of IEC and UL fuses 3.2.
More informationCurrent valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
More informationControls Solid-State Switching Devices
Controls Solid-State Switching Devices Introduction Overview 3RF21 3RF20 3RF23 3RF29 SIRIUS SC solid-state switching devices Solid-state relays 22.5 mm solid-state relays, 5 mm solid-state relays Solid-state
More informationFuses for Semiconductor Protection - Cylindrical Fuses. Class: Voltage ratings: Current ratings: Standards: Approvals: Features and Benefits
Fuses for Semiconductor Protection - Cylindrical Fuses SIBA cylindrical Ultra-Rapid fuses are available in six different sizes They can be ordered with an integral striker for blown fuse indication or
More informationType: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information
Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC
More information3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,
Automation Technology > Industrial Controls > Switching Devices > Contactors and Contactor Assemblies > Power Contactors for Switching Motors > Contactors SIRIUS 3RT10, 3-pole, 3... 250 kw 3RT1015-1BB41
More informationPower Supplies 3. SDN-P DIN Rail Series
SDN-P DIN Rail Series The SDN DIN Rail power supplies provide industry leading performance. Sag Immunity, transient suppression and noise tolerant, the SDN series ensures compatibility in demanding applications.
More informationMagnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...
Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast
More informationAF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101403D0201 24/03/11 AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF09(Z) contactors are used for controlling power circuits
More informationPlug and Socket Devices CES 63 A Series 8579
www.stahl.de > Switch socket / plug 63 A > Large switch handle with clear switch position indication padlockable in 0- and I-position > Low insertion and withdrawal forces through individually encapsulated
More informationElectronic overload relay EF19 and EF45
Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor
More informationSENTRON Switching and Protection Devices Air Circuit Breakers
Siemens AG 9 SENTRON Switching and rotection Devices Air Circuit reakers 5 5/ Introduction 3WL Air Circuit reakers 3WL Air Circuit reakers/ Non-Automatic Air Circuit reakers up to 63 A (AC) 5/6 General
More informationEmergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN 60204-1, VDE 0113 Part 1
MainswitchSurfacemounting Partno. P3-63/I4/SVB Articleno. 207343 CatalogNo. SP3-063-I4CRQ IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual
More informationSTEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase
Extract from the online catalog STEP-PS/1AC/12DC/1.5 Order No.: 2868567 DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Commercial data EAN 4046356292924 Pack 1 pcs. Customs tariff
More informationManual Motor Starter MS 116 up to 16 A Technical Data
Manual Motor Starter MS 116 up to 16 A Technical Data Type MS 116 Standards: Major International IEC 60 947-4-1 / IEC 60 947-2 and European Standards EN 60 947-4-1 / EN 60 947-2 Approvals, Certificates
More informationHERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
More informationThyristor-controlled power supplies and battery chargers
Thyristor-controlled power supplies and battery chargers Input voltage: 115 / 230 VAC, single phase, 50 / 60 Hz or 208 / 400 / 480 VAC, three phases, 50 / 60 Hz Output voltage: 12 / 24 / 48 / 60 / 72 /
More informationTechnical data UNIBLOCK UBSF 180 625
Data TECHNICL DT Technical data UNIBLOCK UBSF 80 6 Output data Type UBSF 80 UBSF 0 UBSF 00 UBSF 6 Output power 80 kv 0 kv 00 kv 6 kv Output voltage 80/77 V 0/ V 0/ V 0/ V Output current 7 8 66 80 Power
More informationD-Line Contactors, Overload Relays and Accessories
D-Line Contactors, Overload Relays and Accessories Class 850 CONTENTS Description......................................................Page General Information...............................................
More informationPhotovoltaic System Overcurrent Protection
Photovoltaic System Overcurrent Protection Photovoltaic System Overcurrent Protection Introduction Solar Photovoltaic (PV) systems have, over the last fifty years, evolved into a mature, sustainable and
More informationDEK-REL- 24/1/SEN. Extract from the online catalog. Order No.: 2964050
Extract from the online catalog DEK-REL- 24/1/SEN Order No.: 2964050 Relay terminal block for sensor, with soldered-in miniature relays, contact (AgNi+Au): small to medium loads, 1 N/O contact, input voltage
More informationFeed-through terminal block - SSK 110 KER-EX - 0502058
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid
More informationBimetallic Overload Relay Specifications
Technical Data Bimetallic Overload Relay Specifications Bulletin Number 193K, 193T1 Topic Page Product Overview 2 Standards compliance and Certifications 2 General Specifications 193K 3 Approximate Dimensions
More informationTechnicaldata General
Currenttransformer-operatedoverloadrelay,60-90A,1N/O+1N/C Partno. ZW7-90 Articleno. 002618 CatalogNo. XTOT090C3S Deliveryprogramme Product range ZW7 current transformer-operated overload relays Description
More informationElectronic overload relay EF65, EF96 and EF146
Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays.
More informationActuator-Sensor-Interface
Selection and ordering data Design Order No. Price Pack 3RX9 307-0AA00 3RX9 307-1AA00 4FD5 213-0AA10-1A 3RX9 305-1AA00 3RX9 306-1AA00 Single output IP 65 current 2.4 A Rated input voltage DC 24 V current
More informationSICONT Limit Switches Type 3SE3 upto 500 VAC, 600 VDC, 10A
s SICONT Limit Switches Type 3SE3 upto 500 VAC, 600 VDC, 10A Introduction The technical and descriptive information on the function, construction and selection of the new types of 3SE3 limit switches is
More informationHigh Speed Fuses. High Speed Fuses
Section Contents Page General Applications........................ 9-95 North American fuses & accessories............9-113 DFJ - High speed Class J fuse...................97 Square Body fuses & accessories............
More informationRenewable energy. Inverters - Socomec G-1. Load break switches (Isolators) - Socomec G-2. Fuses - df G-3. Fuse bases.
G Product page Inverters - Socomec G-1 Load break switches (Isolators) - Socomec G-2 Fuses - df G-3 Fuse bases Surge protection - df G-3 - Wohner G-5 - CPT G-4 - Dehn G-5 Connectors - Wieland G-6 Cable
More informationProduct and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.
Product and Applications Description The power supply units N 125/x2 can supply DC 24 V power from an additional pair of terminals (yellowwhite). This DC 24 V output voltage can be used to power e.g. an
More informationPower Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1
Power Supply Unit, Primary Switched, Narrow Design MINI POWER provides: Extra narrow design with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide-range input
More informationR4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0
FieldBarrier Features Assembly 8... 12 outputs Ex ia IIC, FISCO and Entity Advanced fault isolation and diagnostics at the spur FieldBarrier in Zone 1/Div. 2 Instruments in Zone 0...1/Div. 1 For FOUNDATION
More informationMicro Contactors. Micro Contactor Relays. Micro Contactors With Solder Pins. Coil voltages. Micro Reversing Contactor. Technical Data.
Micro Contactors Micro Contactor Relays 0 Micro Contactors Micro Contactors With Solder Pins Coil voltages Micro Reversing Contactor 3 Technical Data 4 Dimensions 8 9 Micro Contactor Relays 4pole C Operated
More informationPositive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous
Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of
More informationCONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.
425 CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE General purpose single phase thyristors and solid state relays Product data abc 425 EUROCUBE A complete range of low cost solid state relays and
More informationCompactLogix Power Supplies Specifications
Technical Data CompactLogix Power Supplies Specifications 1768 CompactLogix Power Supplies Catalog Numbers 1768-PA3, 1768-PB3 1769 Compact I/O Power Supplies Catalog Numbers 1769-PA2, 1769-PB2, 1769-PA4,
More informationMini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear
Mini Motor Contactor J7KNA ) Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN-rail) Range from 4 to 5.5 (AC 3, 380/415V) 4 -main pole version (4 AC
More informationResidual Current Protective Devices
Residual Current Protective Devices /2 Introduction / 5SM3 RCCBs /9 SIQUENCE, 5SM3 and 5SU1 universal -sensitive RCCBs, type B and type B+ /12 Additional components /1 5SM2 RC units /18 5SU1 RCBOs /25
More informationUncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M
Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M The details make the difference MCB S 200/S 200 M A range designed to ensure efficiency and protection
More information40.3. Control Relays and Timers
.3 Contents EASY500/700/800 Intelligent Relays........ EASY/MFD Expansion Modules............ MFD Intelligent Relays................... EASY/MFD Communication Modules....... EASY/MFD Power Supplies, Accessories
More informationNF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101433D0201 28/03/11 NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits.
More informationElectronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet
Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order
More informationPCS0100en 02.2008. Persy Control Services B.V. Netherlands
P-Bus Gateway PBGW2.128 Universal gateway between the P-bus protocol and open standard protocols. The variety of available electrical interfaces on the gateway offers a wide range of possibilities for
More informationType: DILM32 10(24V50HZ) Article No.: 277247
Type: DILM32 10(24V50HZ) Article No.: 277247 Ordering information Rated operational current AC 3 400 V I e A 32 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors,
More informationComparative study for cables and busbars
Comparative study for cables and busbars Preliminary considerations To compare the prices of two categories of product as different as traditional cables and busbars, it is necessary to make some preliminary
More informationProtection Equipment
Protection Equipment Price groups 14O, 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J, 4N1 /2 Introduction Motor starter protectors/ circuit breakers SIRIUS 3RV2 motor starter protectors/ circuit breakers up to
More informationType: DILM50(230V50HZ,240V60HZ) Article No.: 277830
Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830 Ordering information Rated operational current AC 3 400 V I e A 50 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase
More informationMolded Case Circuit Breaker Specifications Bulletin Number 140U-D
Technical Data Molded Case Circuit Breaker Specifications Bulletin Number 140U-D Topic Page Product Line Overview 2 Specifications 3 Trip Curves 4 Approximate Dimensions 6 Additional Resources These documents
More informationR.C.C.B. s two-pole LEXIC
87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s two-pole LEXIC 089 06/09/10/11/12/15/16/17/18/ 27/28/29/30/35, CONTENTS PAGES 1. Electrical and mechanical characteristics...
More informationDirectory chapter 02 - DIN Power (to 6 A) Types D, E, F, FM, 2F, F9, interface connectors I/U 02. 01. Technical characteristics types D and E... 02.
Directory chapter 02 - () Types D, E, F, FM, 2F, F9, interface connectors I/U Page Technical characteristics types D and E.............................. 02.10 Type D connectors.................... 02.11
More informationExample of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.
Overview Switch and button modules The dimensions of the switch and button modules are adapted to the electronic components in the integral housing. The modules are equipped with the universal clip-on
More informationCircuit Breakers. Next Generation of Protection Capabilities
Circuit Breakers Next Generation of Protection Capabilities Circuit Breaker Offering Rockwell Automation offers a full line of Allen-Bradley circuit breakers and motor protection devices to help meet many
More informationDigital input modules
8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a
More informationPressure Switch for gas and air
Switch for gas and air GAO-A4 GMH-A4 GML-A4 UL Listed UL 353 File # MH 16628 CSA Certified CSA C22.2 No. LR 53222 Certification file # 201527 FM Approved Class 3510, 3530 File # J.I. 1Y919.AF Commonwealth
More informationSEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use
s 5 146 Synco 200 Signal Converter SEZ220 With preprogrammed standard applications Freely programmable enu-driven operation Use The signal converter is for use in HVAC plant to provide minimum / maximum
More informationYour Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.
Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description
More informationSafety Relays ESM/ESM-F
Safety Relays ESM/ESM-F More than safety. Safety More than safety. Emil Euchner, the company s founder and inventor of the multiple limit switch, circa 1928. Around the world the Swabian specialists in
More informationCQM1-SF200/CS1W-SF200
Safety Relay Unit ( I/O Unit Type) CQM1-SF200/CS1W-SF200 CSM_CQM1-SF200_CS1W-SF200_DS_E_2_1 A Safety Relay Unit That Functions as a I/O Unit. Less Installation Space and Wiring Required. Safety Relay Unit
More informationCircuit Breakers. NRC Series. NRC Series. 900 www.idec.com
Switches & Pilot Lights Display Lights NRC series circuit breakers offer circuit protection which is far superior to using fuses in applications containing relay circuits, motor circuits, heater circuits,
More informationSafety along the complete line: SIRIUS 3SE7 cable-operated switches. sirius COMMANDING & SIGNALING
Safety along the complete line: 3SE7 cable-operated switches sirius COMMANDING & SIGNALING Everything well under control. 3SE7 cable-operated switches With cable-operated switches from our 3SE7 product
More information8146/5 Series Breaker Panelboards
8146/5 Series Breaker Panelboards DISTRIBUTION BREAKER PANELBOARDS FOR HAZARDOUS & CORROSIVE ENVIRONMENTS Breaker Panels Features: Wide variety of Flameproof branch circuit breakers for Zone 1 & Division
More informationVario-Series Accessories
Accessories and spare parts for GMW analogue panel meters and controllers Current Transformers pages 2-9 Shunt Resistors 10-11 Voltage Dividers 12 Power supply for indicator/controllers 13 Blanking Plates
More informationMessko. Messko. MTraB - Maintenance Free Dehydrating Breather Ordering specifications 686 - XX - XX - XXX - XX
Ordering specifications MTraB -Series Maintenance Free Dehydrating Breather Part no.: 686 - - - - Form your part number by selecting the individual parameters: For example: 686-10--103- Part no.: Parameter
More informationBritish BS 88 Fuses. Introduction
British BS 88 Introduction British BS 88 Contents Fuse Volts Amp Range Page 0-900 188-190 90-791-19 Accessories Indicator System & Fuse Bases 195 British BS 88 Fuse Ranges Amps Vac Vdc -900 0 150-710 90
More informationSecondary Unit Substations
14 SWITCHGEAR Secondary Unit Substations Overview Siemens offers a wide variety of unit substation designs to meet customer requirements. A unit substation consists of one or more transformers mechanically
More informationBRITISH STYLE SEMICONDUCTOR PROTECTION FUSES
The Edison British Style semiconductor protection fuses include a 660VAC line utilizing new filler technology. These new fuses have greatly reduced peak let-through current and energy under fault conditions
More informationABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG 110 084 R0011
, 2CDG 110 084 R0011 2CDC 071 112 F0008 The Fan Coil Actuator is a modular installation device (MDRC) in pro M design. It is intended for installation in the distribution board on 35 mm mounting rails.
More informationTechnical catalogue. Modular DIN rail components Installation contactors
Technical catalogue Modular DIN rail components Installation contactors Installation Contactors Overview... ESB Installation Contactors 0 A / AC-/AC-7a ESB0...4 4 A / AC-/AC-7a ESB4...5 40 A / AC-/AC-7a
More informationPCB transformers. Short circuit proof PCB transformer VB. General Data. Advantages. Applications. Circuit diagram. Standards & 1 Certifications W v
Short circuit PCB transformer General Data Rated input 230 Vac Rated output 6-2 x 24 Vac Rated power 0.35-3.2 VA Insulation class B Maximum ambient temperature 70 C Efficiency up to 58 % Degree of protection
More informationPHOENIX CONTACT - 2012-12-14. Features
Electronic monitoring relay for phase sequence, phase failure, and asymmetry monitoring Data sheet 101748_en_03 1 Description PHOEIX COTACT - 2012-12-14 Features Increasingly higher demands are being placed
More informationApplication Switchgear for industrial and commercial applications. U e V AC 230/400. 48 (per pole)
Overcurrentswitch,6A,2p,D-Char,AC Partno. FAZ-D6/2 Articleno. 278777 CatalogNo. FAZ-D6/2 Similar to illustration Deliveryprogramme Basic function Miniature circuit breakers Pole 2 pole Tripping characteristic
More informationCatalog. Modular DIN rail components Installation contactors
Catalog Modular DIN rail components Installation contactors 0 CDC00C00 Installation contactors Benefits and features Overview Ordering details ESB installation contactors ESB0 ESB ESB0 ESB 7 EN installation
More informationType: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description
Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display
More informationProduct and functional description
Product and functional description The KNX / DALI gateway N 141/02 is a 4 MU wide, DINrail mounted KNX device with one DALI interface to which up to 64 DALI actuators (e.g. DALI ballasts) can be connected
More informationIEC style contactors - long electrical and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide
- long al and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide range coils +0% to -30% Finger safe terminals Four-pole versions available NO + NC and
More informationTX OPEN RS232/485 module
s 8 185 8185P01 TX-I/O ; DESIGO OPEN TX OPEN RS/485 module for integrating third-party systems and devices to DESIGO (V4 or higher) TXI1.OPEN Platform to integrate third-party systems and devices to the
More informationLC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil
Product data sheet Characteristics LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationABB Inc. April 19, 2011 Slide 1
ABB Automation & Power World: April 18-21, 2011 Allen Austin - Solar Segment Manager North America, Low Voltage Products WLP-123-1-CEU Solar applications for low voltage products ABB Inc. April 19, 2011
More informationFuse Selection Guide
Fuse Selection Guide Although care is taken to properly design electrical and electronic circuits; overcurrents in the form of short-circuits and overload can occur. The sole purpose of fuses and circuit
More informationPlug and Socket Devices SolConeX 16 A Series 8570
www.stahl.de > Switch socket / plug 16 A > Minimal force required to insert and remove > Can be optionally equipped with an auxiliary contact for control and signalling purposes > arge switching handle
More informationOur brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy
Our brand A strong brand for strong products: The ENERGOLINE brand represents our product portfolio of INDUSTRIAL SWITCHGEAR SYSTEMS. Our products are characterized by a high degree of safety, flexibility
More informationElectric Rotary Actuator - On/Off or programmable control actuator
Electric Rotary Actuator - On/Off or programmable control actuator Direct mounting on quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Multi-voltage version Type
More informationMINI MCR-SL-R-UI(-SP)
Resistance/potiposition transducer INTERFACE Data Sheet 0807_en_05 Description PHOENIX CONTACT - 0/008 Features The slim MINI MCR-SL-R-UI... potiposition transducer has a width of only 6. mm and converts
More informationRM4TG20 three-phase network control relay RM4-T - range 200..500 V
Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking
More informationType: DILM9 10(24VDC) Article No.: 276705
Type: DILM9 10(24VDC) Article No.: 276705 Ordering information Rated operational current AC 3 400 V I e A 9 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors, 50
More informationPC 4/ 4-ST-7,62. Extract from the online catalog. Order No.: 1804920
Extract from the online catalog PC 4/ 4-ST-7,62 Order No.: 1804920 The figure shows a 5-pos. version of the product Plug component, nominal current:, rated voltage: 400 V, pitch: 7.62 mm, no. of positions:
More informationPLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357
Series Features: Color coding and pin configuration makes it physically impossible to mate plugs and receptacles of different voltages and current ratings (per IEC 60 309-2). Interlocked switch mechanism
More informationACS-30-EU-EMDR-10-MOD
Multi-application heat tracing Control and Monitoring in commercial and residential buildings Roof & Gutter de-icing sensor module Technical Information Approvals Module IP rating Ambient operating temperature
More information36T Series Snap-Action Temperature Controls
36T Series Snap-Action Temperature Controls Snap-Action Temperature Control The 36T series of 1/2 bimetal temperature controls from Therm-O-Disc offers proven reliability in a compact, versatile, cost-effective
More informationG7SA. Ordering Information. Slim Plug-In Safety Relay. Slim Safety Relay for Machine Control. H Slim body only 13 x 24 x 50 mm
Slim Plug-In Safety Relay Slim Safety Relay for Machine Control H Slim body only 13 x 24 x 50 mm (six poles) H Four-pole and six-pole models are available H Terminal arrangement simplifies PCB pattern
More informationSiemens AG 2011. Switching Devices. Configuration Manual 10/2010 SENTRON. Answers for infrastructure.
Siemens AG 20 Switching Devices Configuration Manual 0/200 SETRO Answers for infrastructure. Siemens AG 20 Siemens AG 20 Switching Devices 4 Introduction 7 Control switches, 5TE8 9 Pushbuttons, 5TE4 Light
More informationControl Devices Catalogue. Control Devices. Preferred and Standard Products
Control Devices Catalogue Control Devices Preferred and Standard Products KOP.J Timer Electronic 22.5 mm Characteristics Mounting KOP.J 22.5 mm mono or multifunction high immunity to interference surface
More information