2 - TeSys motor starters - enclosed version

Similar documents
Motor circuit-breakers

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

ADS8 IP54 Direct-On-Line Starter Technical Focus. Replaces ADS7 Rated up to 9kW

Pendant control stations 6

Products and solutions for lifting systems

Series 8146/5-V37 and Series 8150/5-V37

Circuit Breakers. Next Generation of Protection Capabilities

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

Plug and Socket Devices CES 63 A Series 8579

Products and solutions for pumping, irrigation and piping

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

Catalog January. Heavy industrial power applications Motor contactors and starters

US Breaker Brand 3 Pole AC Contactors (Square D Telemecanique LC1 Replacements)

PSR The compact range Description

Power Generation. Power Control PCL System Generator Set Control

Comparison of NEMA and IEC schematic diagrams

Plug and Socket Devices SolConeX 16 A Series 8570

Manual Motor Starter MS 116 up to 16 A Technical Data

Safety detection solutions

SIRCOVER. Manual changeover switches from 125 to 3200 A. Changeover switches. Function. Advantages. The solution for.

Control Panel Technical Guide

D-Line Contactors, Overload Relays and Accessories

Thermal-Magnetic Circuit Breaker M1-..

Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, "Flameproof Enclosure" Series

Circuit Breakers. NRC Series. NRC Series

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

R.C.C.B. s two-pole LEXIC

Electronic overload relay EF19 and EF45

Products and solutions for machine builders (OEM) 100% electricity

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

Electronic overload relay EF65, EF96 and EF146

THERMAL RELAYS, MOTORSTARTERS

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Technicaldata General

Tmax MCCBs. Molded case circuit breakers. Tmax

Electrical auxiliaries 0 For i DPN (DPN), C60 and C120

Mureva Assembly surface mounted wiring devices

Spare parts Catalogue

VLT Series 3500 Adjustable Frequency Drive Instruction Manual

WE-350 Series ¼ Turn Electric Actuator

Cam switches. Page. Overview 4-2. ON-OFF switches, main switches, maintenance switches 4-3. Changeover switches, reversing switches 4-5

Sentron Series Circuit Breakers

Wiring diagrams. Compact NSX. Contents

8146/5 Series Breaker Panelboards

IEC style contactors - long electrical and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide

3RV Motor Starter Protectors up to 100 A

HERZ-Thermal Actuators

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear

General Informations 2 Technical data 3 Basic designs 4-8

How can a charging station for electric vehicles be set up simply and safely?

9 Control Equipment. Control Button Series 8082

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A

BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview

Masterpact NW Circuit breakers and switch-disconnectors from 800 to 6300 A

Safety automation solutions

FIREDEX Conventional Fire Panels

UniGear ZS1. Medium voltage, arc proof, air insulated switchgear for primary distribution

Overload Relay Heater Tables

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

General 1-2-Opto-electronics Safety Switches 4-Emergency

SENTRON Switching and Protection Devices Air Circuit Breakers

AF / AF09Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

3K Load-Break Switches The Program for Safety and Performance. sentric

Unified requirements for systems with voltages above 1 kv up to 15 kv

know-how Giant in distributing electricity for industry Prisma GK

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

Data Sheet. Electro-mechanical counters Hengstler 800 series

Micro Contactors. Micro Contactor Relays. Micro Contactors With Solder Pins. Coil voltages. Micro Reversing Contactor. Technical Data.

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Safe switching and monitoring Solenoid Interlocks

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors

Safety dialogue solutions

LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE

REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO)

Renewable energy. Inverters - Socomec G-1. Load break switches (Isolators) - Socomec G-2. Fuses - df G-3. Fuse bases.

Actuator-Sensor-Interface

ABB. Installation Enclosures Meter Boxes. SMB s. DMB s. Enclosures

Type: DILM50(230V50HZ,240V60HZ) Article No.:

Industrial Automation Commonly-Used Terms

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

Notes on Product Changeover

Cable Plug acc. to DIN EN , Form A

more than a breaker it s a breakthrough Compact NSX

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA

Trade of Electrician. Three-phase Distribution Boards And Socket Circuits

ACS-30-EU-EMDR-10-MOD

Dimensions, Inches (mm) No. of Poles Width Height Depth 2, (210) 16 (407) 5.5 (140) (283) 16 (407) 5.5 (140)

Manual motor starter MS116

Type: DILM9 10(24VDC) Article No.:

REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16

3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,

THE ADVANTAGES ARE YOURS

Control. Overview. Contents

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Type: DILM32 10(24V50HZ) Article No.:

SMS 4 / SMS 5 safety mat Product information

Product and functional description

ATS - Automatic Changeover

Transcription:

Contents 0 << Back - TeSys motor starters - enclosed version Selection guide..............................................page / VARIO enclosed switch disconnectors b Pre-assembled............................................. page / b Assembled by user.......................................... page /5 b Add-on modules............................................ page /6 thermal-magnetic motor circuit-breakers b Type GV ME v Standard............................................... page /10 v Assembly of a safety enclosure............................. page /1 D.O.L. starters for motor control b 0.55 to 30 kw v With manual control and with magnetic circuit-breakers........... page /1 b. to 5 kw v Without isolating device................................... page /16 v With isolating device...................................... page /0 b 0.5 to 7.5 kw v With 3-phase thermal overload relay......................... page / b 0.37 to 5.5 kw v With thermal magnetic circuit-breaker and contactor............. page /6 Star-delta starters for motor control b 5.5 to 13 kw v Without isolating device................................... page /8 b 7.5 to 75 kw v With isolating device...................................... page /3 b 90 to 375 kw v Without isolating device................................... page /38 D.O.L. starters for control in category AC-1 b Without isolating device..................................... page /0 b With isolating device........................................ page / integral 18, 3 and 63 contactor breakers and reversing contactor breakers b Enclosures and door interlock mechanisms for customer assembly... page /8 /0

integral 3 and 63 contactor breakers and reversing contactor breakers b Enclosures............................................... page /5 b Door interlock mechanisms.................................. page /55 b For control and protection of motors........................... page /56 b For control and protection of resistive circuits in category AC-1...... page /58 b Auxiliary contact blocks and accessories....................... page /59 D.O.L. starters for motor control for use on a machine subject to the application of Machinery Directive 98/37/CE b Non-reversing starters...................................... page /6 b Reversing starters......................................... page /6 Soft starters for asynchronous motors Selection guide............................................ page /7 D.O.L. starters for AS-Interface cabling system Selection guide............................................ page /7 b Models LF1, LF, LF7 and LF8............................... page /76 b Models LF1 P, LF P....................................... page /86 b Models LF1 M, LF M...................................... page /87 b Model LF7 P............................................. page /88 b Model LF8 P............................................. page /89 LA9 Z modules for AS-Interface cabling system b For D.O.L. starters........................................ page /10 /1

General selection guide TeSys enclosed starters Applications D.O.L. starters Type Standard starters Standard power ratings of 3-phase motors in AC-3 00/15 V 37 kw 0.06 5 kw 0.55 30 kw 0.37 5.5 kw 0.5 5 kw Starters Manual p p p Auto p p Isolation Switch p Circuit-breaker p p p Disconnector Protection Short-circuit p p p Overload p p p p Communication References Non-reversing VpF VCFN VpFX GV ME GV3 CE GV LC GV NGC LE1 GVME LE1 M LE1 D Reversing LE K LE D Pages / and /5 /10 and /11 /1 /6 /16, /17 and / /

Soft start units Starters for safety applications Starters for use on AS-Interface line Standard star-delta starters. 5 kw 0.06 11 kw 0.06 9 kw 0.06 9 kw 0.06 5.5 kw 5.5 13 kw 7.5 75 kw p p p p p p p p p p p p p p p p p p p p p p p p p p p p LE K LE D GV ME LG1 K LG1 D LG7 K LG7 D LJ7 K LF1 M LF1 P LF7 P LE3 K LE3 D LE3 F LE6 D LE3 D LE8 K LE8 D LE D LG8 K LJ8 K LF M LF P LF8 P /0 and /1 /1 and /13 /63 /6, /63, /68 and /69 /86 to /89 /8, /9 and /38 /3 and /33 /3

References starters VARIO enclosed switch disconnectors, pre-assembled 58058 58057 58056 58055 VCF 0GE VCF 3GE VBF 0GE switch disconnectors for high performance applications b Marking on operator O. b 3-pole rotary switch disconnectors, 10 to 10 A, conforming to IEC 6097--1 and IEC 600. b Padlockable operating handle (padlocks not included). b IP 65 degree of protection enclosures, sealable and lockable. b Cover lockable in position I (ON) up to 63 A rating. 3-pole main and emergency stop switch disconnectors (1) Operator lthe Power Handle Front plate AC-3 Dimensions at 00 V Red, padlockable with up to 3 padlocks (Ø to Ø 8 shank) Red, padlockable with up to 3 padlocks (Ø to Ø 8 shanks) Incorporated switch body Possible attachments () b 3-pole rotary switch disconnectors, 10 to 3 A, conforming to IEC 6097--1. b Degree of protection IP 55. Reference Weight mm A kw kg Yellow 60 x 60 Yellow 90 x 90 3-pole main switch disconnectors (1) Black, padlockable with up to 3 padlocks (Ø to Ø 8 shank) Black, padlockable with up to 3 padlocks (Ø to Ø 8 shank) Black 60 x 60 Black 90 x 90 10 V0 VCF 0GE 0.500 16 5.5 V01 VCF 01GE 0.500 0 7.5 V0 VCF 0GE 0.500 5 11 V1 VCF 1GE 0.500 3 15 V VCF GE 0.500 50 V3 3 VCF 3GE 0.930 63 30 V 3 VCF GE 0.930 100 37 V5 1 VCF 5GE.190 10 5 V6 1 VCF 6GE.190 10 V0 VBF 0GE 0.500 16 5.5 V01 VBF 01GE 0.500 0 7.5 V0 VBF 0GE 0.500 5 11 V1 VBF 1GE 0.500 3 15 V VBF GE 0.500 50 V3 3 VBF 3GE 0.930 63 30 V 3 VBF GE 0.930 100 37 V5 VBF 5GE.190 10 5 V6 VBF 6GE.190 switch disconnectors for standard applications 3-pole main and emergency stop switch disconnectors (1) Operator lthe Power Incorporated Handle Front plate AC-3 Dimensions at 00 V switch body Red Padlockable, either by 1 (Ø 8 shank) or by 3 padlocks (Ø 6 shank) Possible attachments () Reference Weight mm A kw kg Yellow 60 x 60 10 VN 1 VCFN 1GE () 0. 16 5.5 VN 0 VCFN 0GE () 0. 0 7.5 V0 0 VCFN 5GE 0.51 5 11 V1 0 VCFN 3GE 0.51 3 15 V 0 VCFN 0GE 0.51 (1) For characteristics of switch disconnectors, please consult your Regional Sales Office. () For VCF and VBF enclosures, see page /6. For VCFN enclosures, see page /7. VCFN 1GE Dimensions : page /8 / Schemes : page /9

References starters VARIO enclosed switch disconnectors, assembled by the user 58059 VBFX GE Empty enclosures IP 65 enclosure with red padlockable handle operator and yellow front plate (for mounting a main or emergency stop switch disconnector) For switch body lthe Possible attachments (1) Reference Weight A kg VN 1, VN 0 V0 V 10 3 VCFX GE1 0.30 V0 V 10 3 VCFX GE 0.660 V3 50 3 VCFX GE 0.660 IP 65 enclosure with black padlockable handle and black front plate (for mounting a main switch disconnector) VN 1, VN 0 V0 V 10 3 VBFX GE1 0.30 V0 V 10 3 VBFX GE 0.660 V3 50 3 VBFX GE 0.660 Switch bodies for standard applications () Description Rating Reference Weight A kg 3-pole 10 VN 1 0.110 switch disconnectors 16 VN 0 0.110 580550 Switch bodies for high performance applications () Description Rating Reference Weight A kg 3-pole 10 V0 0.00 switch disconnectors 16 V01 0.00 0 V0 0.00 5 V1 0.00 3 V 0.00 V0 50 V3 0.00 63 V 0.00 (1) See pages /6 and /7. () For characteristics of switch disconnectors, please consult your Regional Sales Office. Dimensions : pages /8 and /9 Schemes : page /9 /5

References starters VARIO enclosed switch disconnectors Add-on modules 580589 58059 Add-on modules for enclosures VCF and VBF Description Rating Reference Weight A kg VZ 0 VZ 11 Main pole module (mounted in enclosure) 10 VZ 0 0.050 16 VZ 01 0.050 0 VZ 0 0.050 5 VZ 1 0.050 3 VZ 0.050 50 VZ 3 0.100 63 VZ 0.100 580595 580596 Neutral pole modules with early make and late break contacts 10 to 3 VZ 11 0.050 50 and 63 VZ 1 0.100 100 and 10 VZ 13 0.50 Earthing modules 10 to 3 VZ 1 0.050 50 and 63 VZ 15 0.100 100 and 10 VZ 16 0.50 VZ 15 VZ 0 Description Type of contacts Reference Weight kg Auxiliary contact block modules with auxiliary contacts N/O + N/C (1) VZ 7 0.050 N/O + N/O VZ 0 0.050 Maximum number of add-on modules that can be fitted on a switch body 1 add-on module on each side of the switch body VZ 7 or VZ 0 + V0p + VZ 7 or VZ 0 or or VZ 11 or VZ 1 + V0 + VZ 11 or VZ 1 or or VZ 1 or VZ 15 + to + VZ 1 or VZ 15 or or VZ 0p/VZ 0 to VZ + V + VZ 0p/VZ 0 to VZ add-on modules on each side of the switch body VZ 0p + VZ 0p + V0p + VZ 0p + VZ 7 or VZ 0 or VZ 11 or VZ 1 VZ 0 + VZ 0 + V0 + VZ 0 + VZ 7 or VZ 0 or VZ 11 or VZ 1 VZ 1 + VZ 1 + V1 + VZ 1 + VZ 7 or VZ 0 or VZ 11 or VZ 1 VZ + VZ + V + VZ + VZ 7 or VZ 0 or VZ 11 or VZ 1 VZ 3 + VZ 3 + V3 + VZ 3 + VZ 7 or VZ 0 or VZ 1 or VZ 15 VZ + VZ + V + VZ + VZ 7 or VZ 0 or VZ 1 or VZ 15 Note: The add-on modules mounted next to the switch body are main pole modules. Maximum of 3 main pole modules per switch body. (1) Late make N/O, early break N/C contacts Schemes : page /9 /6

References (continued) starters VARIO enclosed switch disconnectors Add-on modules 580597 Add-on modules for enclosures VCFN 1GE and 0GE Description Rating Reference Weight A kg Main pole modules 10 VZN 1 0.00 16 VZN 0 0.00 VZN 11 Neutral pole module 10 and 16 VZN 11 0.00 with early make and late break contacts Earthing module 10 and 16 VZN 1 0.016 580598 Description Type of contacts Reference Weight kg Auxiliary contact block modules 1 N/O late make contact VZN 05 0.00 1 N/C early break contact VZN 06 0.00 VZN 1 Maximum number of add-on modules that can be fitted on a switch body 580599 VZN 1 or VZN 0 + VN 1 + VZN 1 or VZN 0 or VZN 11 or or or VZN 05 VN 0 VZN 05 or VZN 06 or VZN 05 or VZN 06 VZN 1 Schemes : page /9 /7

Dimensions starters VARIO enclosed switch disconnectors Dimensions VCFN 1GE to VCFN 0GE 90 131 106 8,5 Cable glands: x 16 P top and bottom. VCF or VBF 0GE to GE VCFX or VBFX GE1 to GE b c1 c a a b c c1 H VpF 0GE to VpF GE, VpFX GE1 (1) 90 16 85 131 130 VpF 3GE and VpF GE () 150 170 106 15 16 VpFX GE and VpFX GE () 150 170 106 15 16 (1) Cable glands: x 16 P top and bottom. () Cable glands: x 16/1/9 P top and bottom. VCF or VBF 5GE and 6GE 01 80 H 191 16 190 0 References : pages / and /5 Schemes : page /9 /8

Schemes starters VARIO enclosed switch disconnectors Schemes Switch disconnectors or switch bodies Main pole module Neutral pole module Auxiliary contact blocks VZ 7 VZ 0 VZN 05 VZN 06 1 13 1 1 13 3 /T1 /T 6/T3 1 13 1/L1 1 3/L 5/L3 References : pages /5, /6 and /7 /9

References TeSys enclosed starters thermal-magnetic motor circuit-breakers type GV ME and accessories, for customer assembly Thermal-magnetic motor circuit-breakers GV ME For motor circuit-breakers and accessories: see pages 508/3. 51/3 and 51/ 9. Starters consisting of a GV ME motor circuit-breaker in an enclosure conform to standard IEC 6097--1. 50077_1 GV Ithe in enclosure (A) ME 01 ME 0 ME 03 ME 0 ME 05 ME 06 ME 07 ME 08 ME 10 ME 1 ME 16 ME 0 ME 1 0.16 0.5 0. 0.63 1 1.6.5 6.3 9 13 17 1 3 Enclosures for thermal-magnetic circuit-breakers GV ME ME Type Degree of protection Possible number of Reference side-mounting auxiliary contact blocks on GV ME Weight LH side RH side kg 50080_1 GV MC Surface mounting, double insulated with protective conductor. Sealable cover Flush mounting, with protective conductor IP 1 1 1 GV MC01 0.90 IP 55 1 1 GV MC0 0.300 or GV MCK0 (1) 0.0 IP 55 for 1 1 GV MC03 0.300 temperature < + 5 C IP 1 (front face) 1 1 GV MP01 0.115 IP 1 (reduced flush mounting) 1 GV MP03 0.115 IP 55 (front face) 1 1 GV MP0 0.130 GV MP IP 55 (reduced flush mounting) 1 GV MP0 0.130 50078_1 Front plate Description Reference Weight kg For direct control, through a panel, of a chassis mounted GV ME IP 55 GV CP1 0.800 GV CP Accessories common to all enclosures (to be ordered separately) Description Padlocking devices () for GV ME operator (padlocking is only possible in the O position) 1 to 3 padlocks Ø to 8 mm Sold in lots of Unit reference Weight kg 1 GV V01 0.075 50079_1 Mushroom head Stop pushbutton Ø 0 mm, red Spring return () 1 GV K011 0.05 Latching () IP 55 Key release. key n 55 1 GV K01 0.160 Turn to release 1 GV K031 0.115 1 GV K0 (3) 0.10 GV K011 Sealing kit For enclosures and front plate IP 55 10 GV E01 0.01 IP 55 for θ < + 5 C 10 GV E0 0.01 Neutral terminal 100 AB1 VV635UBL 0.015 Partition 50 AB1 AC6BL 0.003 (1) Enclosure GV MCK0 is fitted with a GV K0 mushroom head Stop pushbutton as standard. () Supplied with IP 55 sealing kit. To be fitted with enclosure GV Mp01. (3) Padlockable in Off position using Ø to 8 mm shank padlocks. /10

References TeSys enclosed starters thermal-magnetic motor circuit-breakers type GV3 ME and accessories, for customer assembly 8118 8119 GV3 CE01 Thermal-magnetic motor circuit-breakers GV3 ME For motor circuit-breakers and accessories: see pages 508/5 and 51/5. GV3 ME0: operational current in enclosure limited to 30 A. Starters consisting of a GV3 ME motor circuit-breaker in an enclosure conform to standard IEC 6097--1. Enclosures for thermal-magnetic circuit-breakers GV3 ME Application Type Degree of protection of enclosure Reference Weight kg Motor circuit-breaker up to 30 A with or without accessories Surface mounting IP 55 GV3 CE01.000 Enclosure accessories (to be ordered separately) Description Sealing membrane (1) Sold in lots of Unit reference Weight kg For θ u 5 C 10 GV1 EA01 0.01 For θ < 5 C (silicone) 10 GV1 EA0 0.01 IP 55 padlocking device for operators (when padlocked, the motor circuit is automatically in the Open (OFF) position) 1 GV1 V01 0.0 GV1 V01 Stop pushbutton Ø 0 mm, red mushroom head (supplied with IP 55 sealing kit) Spring return 1 GV1 K01 0.05 Latching Key release, key n 55 Turn to release 1 GV1 K0 0.095 1 GV1 K03 0.05 530080 (1) Spare part GV1 K01 /11

References TeSys enclosed starters thermal-magnetic motor circuit-breakers type GV ME and accessories Assembly of a safety enclosure References Thermal-magnetic motor circuit-breakers GV ME For motor circuit-breakers and accessories: see pages 508/3, 51/ and 51/ 3. Starters consisting of a GV ME motor circuit-breaker in an enclosure conform to standard IEC 6097--1. GV Ithe in enclosure (A) ME 01 ME 0 ME 03 ME 0 ME 05 ME 06 ME 07 ME 08 ME 10 ME 1 ME 16 ME 0 ME 1 0.16 0.5 0. 0.63 1 1.6.5 6.3 9 13 17 1 3 ME 50077_1 GV MC Enclosures for thermal-magnetic circuit-breakers GV ME Type Degree of protection Possible number of side-mounting auxiliary contact blocks on GV ME Reference Weight LH side RH side kg Surface IP 1 1 1 GV MC01 0.90 mounting, double insulated with IP 55 1 1 GV MC0 0.300 protective conductor. or GV MCK0 (1) 0.0 Sealable cover IP 55 for temperature < + 5 C 1 1 GV MC03 0.300 Accessories common to all enclosures (to be ordered separately) Description Sold in Unit lots of reference Padlocking devices () for GV ME operator (padlocking is only possible in the O position) 1 to 3 padlocks Ø to 8 mm Weight kg 1 GV V01 0.075 50079_1 GV K011 Mushroom head Stop pushbutton Ø0mm, red Sealing kit Neutral terminal Spring return () 1 GV K011 0.05 Latching () IP 55 For enclosures and front plate Key release, key n 55 Turn to release 1 GV K01 0.160 1 GV K031 0.115 1 GV K0 (3) 0.10 IP 55 for 10 GV E01 0.01 temperature between + 5 C and + 0 C IP 55 for temperature between - 0 C and + 0 C 10 GV E0 0.01 100 AB1 VV635UBL 0.015 Partition 50 AB1 AC6BL 0.003 Assembly of a safety enclosure (conforming to standards IEC 6097--1, IEC 600 and IEC 609) Type of product Page Reference Enclosure See above GV MCpp Circuit-breaker 3/ GV MEpp Undervoltage trip or INRS trip () 3/53 GV Apppp Latching mushroom head Stop pushbutton See above or GV AXppp GV K01 or GV K031 or GV K0 (1) Enclosure GV MCK0 is fitted with a GV K0 mushroom head Stop pushbutton as standard. () Supplied with IP 55 sealing kit. To be fitted with enclosure GV Mp01. (3) Padlockable in Off position using Ø to 8 mm shank padlocks. () Safety device for dangerous machines conforming to INRS and VDE 0113. /1

Dimensions, mounting TeSys enclosed starters thermal-magnetic motor circuit-breakers type GV ME and accessories Dimensions, mounting Surface mounting enclosures GV MC0p (1) 17 130 8 93 (1) knock-outs for 16 mm plastic cable gland or 16 mm conduit. Surface mounting enclosure GV MCK0 (1) 17 130 8 93 15,5 (1) knock-outs for 16 mm plastic cable gland or 16 mm conduit. Flush mounting enclosures GV MP0p (panel cut-out) GV MP0p GV MGV MP01, MP0 GV MP03, MP0 Front plate GV CP1 71 17 10 9,5 117 133 6 1 11,5 118 133 1 1...6 a 93,5 106,5 71 93 6,5 1 1... 76 93 7,5 GV a MP01, MP0 MP03, MP0 86 /13

Characteristics, references TeSys enclosed starters D.O.L. starters with manual control, with magnetic circuit-breaker, 0.55 to 30 kw Characteristics (1) Conforming to standards IEC 6097-, IEC 6039-1, VDE 0660-10 and EN 6097 Degree of protection conforming to IEC 6059 GV LC: IP 57 GV NGC: IP 07 Operational voltage Ue GV LC: 690 V GV NGC: 500 V Material Polycarbonate () 53370 References Control by black rotary handle, padlockable in Off position (up to 3 padlocks with Ø 8 shank, to be ordered separately) Rating In Breaking capacity Icu conforming to IEC 6097- Reference Weight 0/ 30 V 00/ 15 V 0 V 500 V Magnetic tripping current Id ± 0 % A ka ka ka ka A kg 1.6 100 100 100 100 13 In GV LC006 (3) 0.780 GV LC0pp.5 100 100 100 100 13 In GV LC007 (3) 0.780 53371 100 100 100 100 13 In GV LC008 (3) 0.780 6.3 100 100 100 100 13 In GV LC010 (3) 0.780 GV LC0pp 10 100 100 0 10 13 In GV LC01 (3) 0.780 1 100 50 0 10 13 In GV LC016 (3) 0.780 5337 18 100 50 0 10 13 In GV LC00 (3) 0.780 5 100 50 30 15 1 In GV NGC05.50 3 100 50 30 15 1 In GV NGC03.50 0 100 50 30 15 1 In GV NGC00.50 50 100 50 30 15 1 In GV NGC050.50 GV NGC0pp 63 100 50 30 15 1 In GV NGC063.50 Variants Starters with control by red rotary handle on yellow background Add the letter R to the references selected above. Example: GV LC006 becomes GV LC006R. 53373 Enclosure without circuit-breaker, with rotary handle mounted on cover Description Rating Reference Weight A kg Black rotary handle 1.6 18 GV LC0 0.300 5 63 GV NGC0 0.550 GV LC0 Red rotary handle on yellow background 1.6 18 GV LC0R 0.300 5 63 GV NGC0R 0.550 (1) Circuit-breaker characteristics: GV L: see pages 3/1 and 3/13. NG 15L: product marketed under the Merlin Gerin, brand, please consult your Regional Sales Office. () Avoid placing this material in contact with harsh substances (detergents, chlorine solvents, ketones, alcohol, aromatic hydrocarbons). (3) The following can be fitted by the customer: a GVAD or GVAM auxiliary contact block on the LH side and a GVAp trip on the RH side. Dimensions: page /15 /1 Scheme: page /15

Dimensions, scheme TeSys enclosed starters D.O.L. starters with manual control, with magnetic circuit-breaker, 0.55 to 30 kw Dimensions GV LC006 LC00 GV NGC05 NGC063 10 173 166 88 65 150 38 167 37 186,3 330 Knock-outs or blanking plugs for cable glands Enclosure type At top At bottom ISO ISO GV LC x 0 or x 5 x 0 or x 5 GV NGC x 0 or x 5 or x 3 or x 0 x 0 or x 5 or x 3 or x 0 Scheme /T1 /T 6/T3 1/L1 3/L 5/L3 References: page /1 /15

Characteristics, references TeSys enclosed starters D.O.L. starters for motor control (1). to 5 kw, without isolating device Characteristics Conforming to standards IEC 6097--1 and IEC 6039-1, VDE 0660-10, EN 6097 Degree of protection conforming to IEC 6059 IP 659: LE K IP 657: LEp D09 D35 IP 557: LEp D05 D955 Ambient air temperature Operation: - 5 + 0 C Operating positions Material Same as that of the contactors Polycarbonate (): LE K and LEp D09 D35 Sheet steel: LEp D05 D955 53377 53378 References LE1 D1pp LE D1pp Non-reversing starters Standard power ratings of 3-phase motors 50-60 Hz in category AC-3 0 V 380 V 15 V 0 V 500 V 660 V 30 V 00 V 690 V Maximum current I the up to Basic reference, to be completed by adding the voltage code (3) Weight kw kw kw kw kw kw A kg. 5.5 5.5 9 LE1 D09pp 0.90 3 5.5 5.5 5.5 7.5 7.5 1 LE1 D1pp 0.90 7.5 9 9 10 10 18 LE1 D18pp 1.015 5.5 11 11 11 15 15 5 LE1 D5pp 1.015 7.5 15 15 15 18.5 18.5 35 LE1 D35pp.30 11 18.5 30 0 LE1 D05pp.80 15 5 30 30 33 50 LE1 D505pp.850 18.5 30 37 37 37 37 65 LE1 D655pp.850 37 5 5 55 5 80 LE1 D805pp 5.10 5 5 5 5 55 5 95 LE1 D955pp 5.0 Reversing starters 1.5.. 3 6 LE K065pp 1.080. 9 LE K095pp 1.080 LE D09pp ().100 5.5 5.5 9 LE D09pp.100 3 5.5 5.5 5.5 7.5 7.5 1 LE D1pp.100 7.5 9 9 10 10 18 LE D18pp.10 5.5 11 11 11 15 15 5 LE D5pp.570 7.5 15 15 15 18.5 18.5 35 LE D35pp.100 11 18.5 30 0 LE D05pp 5.70 15 5 30 30 33 50 LE D505pp 5.70 18.5 30 37 37 37 37 65 LE D655pp 5.70 37 5 5 55 5 80 LE D805pp 6.700 5 5 5 5 55 5 95 LE D955pp 7.000 (1) Overload protection must be provided by a thermal overload relay, to be ordered separately, see pages 6/16 and 6/17. () Avoid placing this material in contact with harsh substances (detergents, chlorine solvents, ketones, alcohol, aromatic hydrocarbons). (3) Standard control circuit voltages. Volts 8 110 115 0 30 0 380 00 15 0 a 50/60 Hz LE K B7 D7 E7 F7 M7 P7 U7 Q7 V7 N7 R7 LE1, LE D B7 D7 E7 F7 FE7 M7 P7 U7 Q7 V7 N7 R7 Other voltages: please consult your Regional Sales Office. () Selection according to the number of operating cycles, please consult your Regional Sales Office. Dimensions : page /18 Schemes : page /19 /16

References (continued) TeSys enclosed starters D.O.L. starters for motor control (1). to 5 kw, without isolating device 53379 Description Standard versions comprise: b For non-reversing starters: v 1 green Start button I, v 1 red Stop/Reset button O. 533750 LE1 D1ppA0 b For reversing starters: v LE K: - 1 Start button A, - 1 Start button E, - 1 red Stop/Reset button. v LE D09 D35: - 1 -position spring return selector switch I - II, - 1 red Stop/Reset button O, v LE D05 D955: - 1 blue Reset button R. 533751 LE1 D1ppA05 Variants (pre-assembled) Description Application Suffix to be added to the starter reference () No pushbuttons on cover LE1 D09 D955 LE D09 D955 A0 1 green Start button I 1 green Start button II 1 red Stop/Reset button O LE D05 D955 1 LE1 D1ppA09 1 blue Reset button R LE1 D09 D955 LE K06 and K09 LE D09 D35 A05 53375 1 3-position stay put selector switch ( I - O - II ) ( I : Automatic Start; O : Stop; II : Manual Start) 1 blue Reset button R LE1 D09 D35 A09 1 -position stay put selector switch O - I ( O : Stop; I : Manual Start) 1 blue Reset button R LE1 D09 D35 3 LE1 D1pp3 1 3-position selector switch O - I spring return to centre position ( I : Manual start; O : Stop, stay put) 1 blue Reset button R LE1 D09 D35 A35 533753 LE1 D1ppA35 1 neutral terminal Fitted as standard on LE1 and LE D09 to D35, LE1 and LE D05 to D955 starters ordered with V (M7), 30 V (P7) or 0 V (U7) control supply Mounting of an LC1 D09 or D1 contactor in an enclosure identical to LE1 D18 (3) Accessory (for customer assembly) (1) See previous page. () Example: LE1 D09F7A0. (3) See dimensions see page /18. LE1 D05 D955 LE K06 and K09 LE D05 D955 LE1 D09 LE1 D1 Description Application Reference Weight kg Start pushbutton latching device for stay put operation (Start-Stop) LE1 D05 D955 LA9 D09907 0.060 A59 T Other versions Possible combinations of variants. Please consult your Regional Sales Office. Schemes : page /19 /17

Dimensions TeSys enclosed starters D.O.L. starters for motor control. to 5 kw, without isolating device Dimensions LE1 D09 and D1 LE1 D09 and D1ppT LE1 D18 D35 and LE D09 D35 LE1 D05 D655 c1 166 88 150 c1 01 183 31 195 101 c1 105 181 c1 c1 LE1 D LE D c1 Standard version 18.5 Standard version 153.5 160 Standard version 161 Variant A0 10 Variant A0 15 15 Variant A0 150 Variant A05 18.5 Variant A05 153.5 153.5 Variant A05 161 Variant A09 135 Variant A09 160 Variant 3 135 Variant 3 160 Variant A35 135 Variant A35 160 LE K06 and K09 19 10 165 150 16 8 175 LE1 D805, LE1 D955 and LE D05 D655 LE D805 and D955 307 165 87 195 c1 165 57 c1 5 367 c1 LE1 D LE D c1 Standard version 176 176 Standard version 19 Variant A0 165 165 Variant A0 190 Variant A05 176 Variant A05 19 Variant 1 176 Knock-outs or blanking plugs for cable glands Type of enclosure At top At bottom PG ISO PG ISO LE1 D09 and D1 x 0 x 13 or x 16 x 0 LE1 D18 D35 and LE D09 D35 x 0 or x 5 x 16 or x 1 x 0 or x 5 LE D05 1 x 13 and 1 x 1 1 x 0 and 1 x 5 1 x 13 and x 1 1 x 0 and x 5 LE1 D05 D655, LE D505 and D655 1 x 13 and 1 x 9 1 x 0 and 1 x 3 1 x 13 and x 9 1 x 0 and x 3 LE1 or LE D805 and D955 1 x 13 and 1 x 36 1 x 0 and 1 x 0 1 x 13 and x 36 1 x 0 and x 0 LE K x 13 and x 16 x 0 x 13 and x 16 x 0 References : pages /16 and /17 Schemes : page /19 /18

Schemes TeSys enclosed starters D.O.L. starters for motor control. to 5 kw, without isolating device Schemes LE1 D09 D955 LE1 D09 D955 Variant A0 or A05 L1 L U V W L3 A B I O A A B O Remote control l 1 13 1 A LE K06, K09 LE K06, K09 Variant A05 L1 L L3 A A R O KM Remote control KM KM KM U V W B A A KM B A A KM LE D09 D955 LE D09 D35 LE D05 D955, LE D09 D955 with variants A0 or A05 L1 L L3 A A R 1 KM S1 I II O Remote control l l KM KM KM KM KM KM U V W B A A B A A Connections A B 0 V, 30 V, 0 V LE K, LE1 and LE D09 and D1 L3 Neutral LE1 and LE D18 D955 L3 Neutral terminal 380 V, 00 V, 15 V, 0 V All products L3 L1 Other voltages LE1 and LE D09 D35 Terminal 1 Terminal LE K, LE1 and LE D05 and D955 Direct connection References : pages /16 and /17 Dimensions : page /18 /19

Characteristics, references TeSys enclosed starters D.O.L. starters for motor control (1). to 5 kw, with isolating device Characteristics Conforming to standards IEC 6097--1 and IEC 6039-1, VDE 0660-10, EN 6097 Degree of protection conforming to IEC 6059 IP 659: LEp K IP 657: LEp D09 D35 IP 557: LEp D06 D806 Ambient air temperature Operation: - 5 + 0 C Operating positions Material Same as that of the contactors Polycarbonate (): LEp K and LEp D09 D35 Sheet steel: LEp D06 D806 533769 533770 References LE D1pp LE8 D1pp Non-reversing starters Standard power ratings of 3-phase motors 50-60 Hz in category AC-3 0 V 30 V 380 V 00 V 15 V 0 V 500 V 660 V 690 V Maximum current I the up to Fuses to be fitted by the customer Size Type am Basic reference, to be completed by adding the voltage code (3) (1) Overload protection must be provided by a thermal overload relay, to be ordered separately, see pages 6/16 and 6/17. () Avoid placing this material in contact with harsh substances (detergents, chlorine solvents, ketones, alcohol, aromatic hydrocarbons). (3) Standard control circuit voltages. Volts 8 110 115 0 30 0 380 00 15 0 a 50/60 Hz LEp K B7 D7 E7 F7 M7 P7 U7 Q7 V7 N7 R7 LEp D B7 D7 E7 F7 FE7 M7 P7 U7 Q7 V7 N7 R7 Other voltages: please consult your Regional Sales Office. () Selection according to dimensions and the number of operating cycles, please consult your Regional Sales Office. (5) Supplied with 3 cable entries. Weight kw kw kw kw kw kw A A kg 1.5.. 3 6 10 x 38 10 LE K065pp 1.50. 9 10 x 38 1 LE K095pp 1.50 or LE D09pp () 1.960. 5.5 9 10 x 38 1 LE D09pp 1.960 3 5.5 5.5 5.5 7.5 1 10 x 38 16 LE D1pp 1.960 7.5 9 9 10 18 10 x 38 0 LE D18pp.00 5.5 11 11 11 15 5 10 x 38 5 LE D5pp.00 7.5 15 15 15 18.5 18.5 35 1 x 51 3 LE D35pp 5.190 11 18.5 30 0 1 x 51 0 LE D06pp 5.770 15 5 30 30 33 50 x 58 63 LE D506pp 6.0 18.5 30 37 37 37 37 65 x 58 80 LE D656pp 6.670 37 5 5 55 5 80 x 58 80 LE D806pp (5) 7.100 Reversing starters 1.5.. 3 6 10 x 38 10 LE8 K065pp 1.600. 9 10 x 38 1 LE8 K095pp 1.600 or LE8 D09pp () 3.550 5.5 9 10 x 38 1 LE8 D09pp 3.550 3 5.5 5.5 5.5 7.5 1 10 x 38 16 LE8 D1pp 3.550 7.5 9 9 10 18 10 x 38 0 LE8 D18pp 3.700 5.5 11 11 11 15 5 10 x 38 5 LE8 D5pp.670 7.5 15 15 15 18.5 18.5 35 1 x 51 3 LE8 D35pp 5.800 11 18.5 30 0 1 x 51 0 LE D06pp 1.170 15 5 30 30 33 50 x 58 63 LE D506pp 1.700 18.5 30 37 37 37 37 65 x 58 80 LE D656pp 1.770 37 5 5 55 5 80 x 58 80 LE D806pp 16.000 Dimensions: page / /0 Schemes: page /3

References (continued) TeSys enclosed starters D.O.L. starters for motor control (1). to 5 kw, with isolating device 533771 LE D1ppA0 Description Standard versions comprise: b For non-reversing starters: v LE K and LE D09 D656-1 green Start button I, - 1 red Stop/Reset button O. v LE D806 - no pushbuttons on cover b For reversing starters: v LE8 K : - 1 Start button A, - 1 Start button E, - 1 red Stop/Reset button. v LE8 D09 D35 : - 1 -position spring return selector switch I - II, - 1 red Stop/Reset button O, v LE D06 to D806: - no pushbuttons on cover. Protection Power circuit Control circuit LE and LE8 K 1 3-pole isolating device None LE and LE8 D09 D5 1 3-pole isolating device + 1 additional pole LE and LE D35 D806 1 3-pole isolating device + 1 circuit-breaker GB CB08 53377 Variants (pre-assembled) Description Application Suffix to be added to the starter reference () No pushbuttons on cover LE D09 D656 LE8 D09 D35 A0 LE D1ppA05 1 green Start button I 1 green Start button II 1 red Stop/Reset button O LE D06 D806 1 1 blue Reset button R LE D09 D806 LE8 K06 and K09 LE8 D09 D35 LE D06 D806 A05 1 neutral terminal Fitted as standard on LE D18 D806, LE8 D18 D35 and LE D06 D806 starters ordered with 0 V (M7), 30 V (P7) or 0 V (U7) control supply LE K06 and K09 LE D09 D806 LE8 K06 and K09 LE8 D09 D35 LE D06 D806 A59 Accessory (for customer assembly) Description Application Reference Weight kg Start pushbutton latching device for stay put operation (Start-Stop) LE D06 D656 LA9 D09907 0.060 (1) See previous page () Example: LE D09F7A0. Other versions Possible combinations of variants. Please consult your Regional Sales Office. Dimensions: page / Schemes: page /3 /1

Dimensions TeSys enclosed starters D.O.L. starters for motor control. to 5 kw, with isolating device Dimensions LE K06 and K09, LE8 K06 and K09 LE D09 D35, LE8 D09 D35 31 165 19 0 8 10 175 c1 150 (1) c1 38 330 186 31 c1 c1 LE K LE8 K LE D LE8 D Standard version 16 16 Standard version 175.5 18 Variant A05 139 Variant A0 167 167 (1) For LE8 only Variant A05 175.5 175.5 LE D06 D656 LE D06 D806, LE D806 a-75 31 87 195 00 (1) 3,5 350 35 xm8x5 c1 5 367 31 0 c1 a-50 a a+57,5 c1 c1 a LE D LE D Standard version 01 LE D06, D506, D656 300 Standard version 18 18 Variant A0 190 LE D806 00 Variant A05 18 18 Variant A05 01 LE D806 00 Variant 1 18 (1) + 1 mm with blanking plugs. Knock-outs or blanking plugs for cable glands Type of enclosure At top At bottom PG ISO PG ISO LE and LE8 D09 D35 x 0 or x 5 or x 3 or x 0 x 0 or x 5 or x 3 or x 0 LE D09 D35 x 0 or x 5 x 0 or x 5 LE D06 and LE D06 1 x 13 and 1 x 1 1 x 0 and 1 x 5 1 x 13 and x 1 1 x 0 and x 5 LE1 D506 D656, LE D506 and D656 1 x 13 and 1 x 9 1 x 0 and 1 x 3 1 x 13 and x 9 1 x 0 and x 3 LE D806 and LE D806 1 x 13 and 1 x 36 1 x 0 and 1 x 0 1 x 13 and x 36 1 x 0 and x 0 LE K and LE8 K x 13 and x 16 x 0 x 13 and x 16 x 0 References : pages /0 and /1 Schemes : page /3 /

Schemes TeSys enclosed starters D.O.L. starters for motor control. to 5 kw, with isolating device Schemes LE K06, K09 LE D09 D806 LE K06, K09 LE D09 D35 LE D06 D656 LE D806, LE D09 D656 with variant A0 or A05 Q1 L1 L L3 A A Q1 Q1 A F1 Q1 A F1 Q1 U V W B I O A B I 18 17 O A B l O A B O Remote control l 1 13 1 A LE8 K06, K09 LE8 K06, K09 Variant A05 L1 L L3 A A Q1 Q1 R O Remote control KM KM KM KM U V W B A A KM B A A KM LE8 D09 LE D806 LE8 D09 D35 LE D06 D806 Q1 L1 L L3 A Q1 Q1 A F1 Q1 O 1 KM1 KM S1 I II O Remote control l l 13 1 KM KM KM KM KM KM U V W B A A B A A Connections A B 0 V, 30 V, 0 V LE and LE8 K, LE and LE8 D09 and D1 L3 Neutral LE D18 D806, LE8 D18 D35 and LE D06 D806 L3 Neutral terminal 380 V, 00 V, 15 V, 0 V All products L3 L1 Other voltages LE and LE8 D09 D35 Terminal 1 Terminal LE and LE D06 D806 Direct connection References : pages /0 and /1 Dimensions : page / /3

Characteristics, references TeSys enclosed starters D.O.L. starters for motor control 0.5 to 7.5 kw with 3-phase thermal overload relay with 3 protected phases Characteristics (1) Conforming to standards IEC 6097--1, IEC 6039-1, VDE 0660-10 and EN 6097 Degree of protection conforming to IEC 6059 IP 65 Ambient air temperature Operation: - 5 to + 0 C Operating positions Same as for the k contactors Material Self-extinguishing ABS 533788 References Non-reversing starters Starter LE1 M, combined with short-circuit protection components, provides type 1 or type coordination, depending on the type of devices used. Standard power ratings of 3-phase motors 50-60 Hz in category AC-3 0 V 30 V 0 V 380 V 00 V 15 V Setting range of thermal overload relay LR K () Basic reference, to be completed by adding the voltage code (3) Weight kw kw kw kw A kg 0.1 0.1 0.5 0.5 0.5 0.8 LE1 M35pp05 0.600 0.18 0.18 0.37 0.37 0.8 1. LE1 M35pp06 0.600 533789 0.5 0.5 0.55 0.55 1. 1.8 LE1 M35pp07 0.600 0.37 0.37 1.1 0.75 1.8.6 LE1 M35pp08 0.600 0.55 0.55 1.5 1.5.6 3.7 LE1 M35pp10 0.600 1.1 0.75.. 3.7 5.5 LE1 M35pp1 0.600 1.5 1.1 3 3 5.5 8 LE1 M35pp1 0.600.. 8 11.5 LE1 M35pp16 0.600 LE1 M35pppp 3 3 5.5 5.5 10 1 LE1 M35pp1 0.600 3.7 7.5 7.5 1 16 LE1 M35pp 0.600 Description b The standard version comprises: v 1 TeSys contactor LC1 Kpp, v 1 TeSys thermal overload relay LR K, v 1 green Start button I, v 1 red Stop/Reset button O/R, v 1 yellow operating indicator. Variant Replacement part b Control may be pulsed or maintained. b An earth terminal and a neutral terminal are provided on the bottom of the enclosure. b For safey applications, see enclosed starters: GV MC, LG1 K, LG1 D, LG7 K, LG7 D, LJ7 K, LG8 K and LJ8 K. Starter without thermal overload relay LR K Delete the last digits of the starter references selected above. Example: LE1 M35pp Description Basic reference, to be completed by adding the voltage code (3) Weight kg Contactor LC1 KppA80 0.180 (1) For characteristics of TeSys k contactor, see pages 6/8 and 6/9. For characteristics of TeSys thermal overload relay LR K, see pages 5/6 to 5/9. () Thermal overload relay fitted as standard. (3) The contactor coil is pre-wired between phases of the power circuit. The codes indicated below therefore correspond to the power circuit voltage. Volts 0 30 0 380 00 15 0 a 50/60 Hz Code B7 M7 P7 U7 Q7 V7 N7 R7 Example: 380/00 V 3-phase supply, kw motor: LE1 M35Q716. Dimensions : page /5 Schemes : page /5 /

Dimensions, schemes TeSys enclosed starters D.O.L. starters for motor control 0.5 to 7.5 kw with 3-phase thermal overload relay with 3 protected phases Dimensions LE1 M35 (1) 108 78 160 130 (5"1/8) Knock-outs or blanking plugs for cable glands Enclosure type At top At bottom PG ISO PG ISO LE1 M x 13 to x 1 x 0 or x 5 x 13 to x 1 x 0 or x 5 (1) Can be mounted on machine panel or frame. Knock-outs for x 13 P cable glands. Schemes LE1 M35 L1 L L3 1/L1 3/L 5/L3 Choice of type of control built into the product Control by latching pushbuttons Control by spring return pushbuttons A A I 1 3 5 13 I 95 1 13 KM1 I O/R 95 1 13 6 1 A O 96 96 6 A H1 A H1 O/R Reset/OR U V W B B 6 T1 T T3 M Connection A B 0 V, 30 V, 0 V L3 Neutral 380 V, 00 V, 15 V, 0 V L3 L1 Other voltages Terminal 1 Terminal References : page / /5

Characteristics, references TeSys enclosed starters D.O.L. starters for motor control, 0.37 to 5.5 kw with thermal magnetic circuit-breaker and contactor 533797 Characteristics Conforming to standards IEC 6097--1, IEC 6039-1, VDE 0660-10 and EN 6097 Degree of protection conforming to IEC 6059 IP 55 Ambient air temperature Operation: - 5 to + 0 C Operating positions Same as for the model k contactors Material Polycarbonate (1) References Standard power ratings of 3-phase motors 50-60 Hz in category AC-3 30 V 00/ 0 V 500 V 690 V 15 V Setting range of thermal trips Fixed magnetic tripping current 13 Irth Basic reference, to be completed by adding the voltage code () Weight kw kw kw kw kw A A kg 0.18 0.5 0.37 0.55 0.37 0.55 0.37 0.55 0.75 0.75 1.1 1 1.6.5 LE1 GVME06Kpp 1.10 533798 0.37 0.75 0.75 1.1 1.1 1.5 1.6.5 33.5 LE1 GVME07Kpp 1.10 0.55 0.75 1.1 1.5 1.5 1.5.. 3.5 51 LE1 GVME08Kpp 1.10 1.1.. 3 3 6.3 78 LE1 GVME10Kpp 1.10 LE1 GVMEppKpp 1.5.. 3 3 5.5 5.5 7.5 5.5 5.5 7.5 7.5 9 11 6 10 138 LE1 GVME1Kpp 1.10 9 1 170 LE1 GVME16Kpp 1.10 533799 Variants LE1 GVMEK Accessories (to be ordered separately) Description Suffix to be added Weight to the starter reference (3) kg Neutral terminal A59 Description Reference Weight kg Enclosure without starter, with sealing kit fitted (references of combination motor starters for customer assembly, see pages 50/ and 50/3) LE1 GVMEK 0.70 Description Sold in lots of Unit reference Weight kg Padlocking device () 1 to 3 padlocks 1 GV V01 0.075 for GV ME operator (padlocking Ø to 8 mm is only possible in the O position) Mushroom Spring return () 1 GV K011 0.05 head Stop pushbutton Latching () Key release, 1 GV K01 0.160 Ø 0 mm, IP 55 key n 55 red Turn to release 1 GV K031 0.115 1 GV K0 (5) 0.10 Sealing kit IP 55 for 10 GV E01 0.01 temperature between + 5 C and + 0 C IP 55 for 10 GV E0 0.01 temperature between - 0 C and + 0 C (1) Avoid placing this material in contact with harsh substances (detergents, chlorine solvents, ketones, alcohol, aromatic hydrocarbons). () Standard control circuit voltages. Volts 8 110 115 0 30 0 380 00 15 0 a 50/60 Hz Item B7 D7 E7 F7 M7 P7 U7 Q7 V7 N7 R7 Other voltages: please consult your Regional Sales Office. (3) Example: LE1 GVME06KF7A59. () Supplied with IP 55 sealing kit. (5) Padlockable in position "O" using Ø to 8 mm shank padlocks. Dimensions : page /7 Schemes : page /7 /6

Dimensions, schemes TeSys enclosed starters D.O.L. starters for motor control, 0.37 to 5.5 kw with thermal magnetic circuit-breaker and contactor Dimensions LE1 GVMEK 183 01 86 9 101 Knock-outs or blanking plugs for cable glands Enclosure type At top At bottom ISO ISO LE1 GV x 0 or x 5 x 0 or x 5 Schemes LE1 GVMEK A L1 L L3 Q1 Q1 O External control I B A Connections A B 0 V, 30 V, 0 V L3 Neutral 380 V, 00 V, 15 V, 0 V L3 L1 Other voltages Terminal 1 Terminal References : page /6 /7

Characteristics, references TeSys enclosed starters Star-delta starters 5.5 to 13 kw, without isolating device (1) Characteristics Conforming to standards IEC 6097--1 and IEC 6039-1, VDE 0660-10, EN 6097 Degree of protection conforming to IEC 6059 IP 659: LE3 K IP 657: LE3 D09 D35 IP 557: LE3 D05 D150 Ambient air temperature Operation: - 5 to + 0 C Operating positions Material References Same as that of the contactors Polycarbonate (): LE3 K and LE3 D09 D35 Sheet steel: LE3 D05 D150 Maximum operating rate: LE3 K: 1 starts/hour and LE3-D: 30 starts/hour. Maximum starting time: 30 seconds. LE3 D: an LAD S timer imposes a delay of 0 ms ± 15 ms on the delta contactor at the moment of changeover to ensure that the star contactor has sufficient breaking time. 53380 Standard power ratings of squirrel cage motors Mains voltage - delta connection Basic reference, to be completed by adding the voltage code (3) Weight 0 V 380/00 V 15 V 0 V kw kw kw kw kg 3 5.5 5.5 5.5 LE3 K065pp 1.60 7.5 7.5 7.5 LE3 K095pp 1.60 or LE3 D09pp () 3.650 5.5 11 11 11 LE3 D1pp 3.650 LE3 D1pp 11 18.5 LE3 D18pp 3.750 15 30 30 30 LE3 D35pp 5.160 18.5 37 37 37 LE3 D05pp 8.160 30 55 59 59 LE3 D505pp 8.150 37 75 75 75 LE3 D805pp 1.000 63 110 110 110 LE3 D115pp.500 75 13 13 17 LE3 D150pp.500 (1) Overload protection must be provided by a thermal overload relay, to be ordered separately. Select appropriate overload relay for setting at 0.58 of the full load rated motor current, see pages 6/16 and 6/17. () Avoid placing this material in contact with harsh substances (detergents, chlorine solvents, ketones, alcohol, aromatic hydrocarbons). (3) Standard control circuit voltages. Volts 8 110 115 0 30 0 380 00 15 0 a 50/60 Hz LE3 K B7 D7 E7 F7 M7 P7 U7 LE3 D B7 D7 E7 F7 FE7 M7 P7 U7 Q7 V7 N7 R7 Other voltages: please consult your Regional Sales Office. () Selection according to dimensions and the number of operating cycles, please consult your Regional Sales Office. Dimensions : page /30 Schemes : page /31 /8

References (continued) TeSys enclosed starters Star-delta starters 5.5 to 13 kw, without isolating device 533805 Description The standard version comprises: LE3 D1ppA0 b LE3 K and LE3 D09 D35: v 1 green Start button I, v 1 red Stop/Reset button O. b LE3 D05 D150: v no pushbuttons on cover. Variants (pre-assembled) Description Application Suffix to be added to the starter reference (1) No pushbuttons on cover LE3 D09 D35 A0 533806 1 green Start button I 1 red Stop/Reset button O LE3 D05 D150 A06 1 blue Reset button R LE3 D09 D805 A05 1 neutral terminal Fitted as standard on starters LE3 D115 and D150 LE3 K065 and K095 LE3 D09 D805 A59 Mechanical interlock Fitted as standard on starters LE3 K and LE3 D09 D35 LE3 D05 to D150 A6 LE3 D1ppA05 (1) Example: LE3 D09F7A0 Other versions Possible combinations of variants. Please consult your Regional Sales Office. Schemes : page /31 /9

Dimensions TeSys enclosed starters Star-delta starters 5.5 to 13 kw, without isolating device Dimensions LE3 K065, K095 LE3 D09 D35 19 10 16 165 8 175 150 c1 38 330 186 c1 Standard version 175.5 Variant A0 167 Variant A05 175.5 LE3 D05 and D505 LE3 D805 D150 a - 75 87 195 b (1) b + 57,5 b - 50 b - 75 c1 5 367 c1 c1 + 15,5 a - 50 a a + 57,5 c1 c1 LE3 a b LE3 D805 D115, D150 Standard version 190 D805 00 00 Standard version 0 5 Variant A05 19 D1155 500 600 Variant A05 18 Variant A06 19 D1505 500 600 Variant A06 18 68 (1) + 1 mm with blanking plugs. Knock-outs or blanking plugs for cable glands Type of enclosure At top At bottom PG ISO PG ISO LE3 D09 D35 x 0 or x 5 or x 3 or x 0 LE3 D05 1 x 9 1 x 3 1 x 9, x 13 and x 1 LE3 D505 1 x 36 1 x 0 1 x 36, x 13 and x 9 x 0 or x 5 or x 3 or x 0 1 x 3, x 0 and x 5 1 x 0, x 0 and x 3 LE3 D805 1 x 36 1 x 0 x 13 and 3 x 36 x 0 and 3 x 0 LE3 K x 13 and x 16 x 0 x 13 and x 16 x 0 References : pages /8 and /9 Schemes : page /31 /30

Schemes TeSys enclosed starters Star-delta starters 5.5 to 13 kw, without isolating device Schemes LE3 K065 and K095 L1 L L3 A U1 V1 W1 O KM KM3 U1 V1 W1 U V W I KM3 KM U V W Recommended cabling for reversal of motor rotation (standard motor, viewed from shaft end). B T A T A Y A KM3 KM A L LE3 D09 D805 LE3 D09 D35 LE3 D05 D805 L1 L L3 A A U1 V1 W1 O KM KM3 U1 V1 W1 U V W I KM Remote control I 17 18 KM U V W Recommended cabling for reversal of motor rotation (standard motor, viewed from shaft end). B KM KM3 A Y KM KM KM3 A A L B KM KM3 A Y KM KM KM3 A A L Note : in accordance with current installation regulations, short-circuit protection must be provided by fuses or a circuit-breaker. LE3 D115 and D150 L1 L L3 A U1 V1 W1 KM KM3 U1 V1 W1 U V W Remote control l 17 18 KM KM U V W Recommended cabling for reversal of motor rotation (standard motor, viewed from shaft end). B F KM3 A Y KM A L KM K A K KM3 A Connections A B 0 V, 30 V, 0 V LD09 and D1 L3 Neutral LE3 D18 to D150 L3 Neutral terminal 380 V, 00 V, 15 V, 0 V All products L3 L1 Other voltages LE3 D09 D35 Terminal 1 Terminal LE3 K and LE3 D05 D150 Direct connection References : pages /8 and /9 Dimensions : page /30 /31

Characteristics, references TeSys enclosed starters Star-delta starters (1) 7.5 to 75 kw with isolating device Characteristics Conforming to standards IEC 6097--1 and IEC 6039-1, VDE 0660-10, EN 6097 Degree of protection conforming to IEC 6059 IP 657: LE6 D09 D18 IP 557: LE3 D36 D806 Ambient air temperature Operation: - 5 to + 0 C Operating positions Material References Same as that of the contactors Polycarbonate (): LE6 D Sheet steel: LE3 D Maximum operating rate: 30 starts/hour. Maximum starting time: 30 seconds. An LA DS timer imposes a delay of 0 ms ± 15 ms on the delta contactor at the moment of changeover to ensure that the star contactor has sufficient breaking time. 53383 Standard power ratings of squirrel cage motors. Mains voltage - Delta connection 0 V 380 V 15 V 0 V 00 V Fuses to be fitted by the customer Size Type am Basic reference, to be completed by adding the voltage code (3) Weight kw kw kw kw A kg 7.5 7.5 7.5 10 x 38 0 LE6 D09pp 3.900 5.5 11 11 11 10 x 38 5 LE6 D1pp 3.900 11 18.5 1 x 51 0 LE6 D18pp.850 15 30 30 30 x 58 63 LE3 D36pp 7.650 18.5 37 37 37 x 58 80 LE3 D06pp 16.900 LE6 D1pp 30 55 59 59 x 58 15 LE3 D506pp 17.000 37 75 75 75 0 160 LE3 D806pp 7.500 (1) Overload protection must be provided by a thermal overload relay, to be ordered separately. Select appropriate overload relay for setting at 0.58 of the full load rated motor current, see pages 6/16 and 6/17. () Avoid placing this material in contact with harsh substances (detergents, chlorine solvents, ketones, alcohol, aromatic hydrocarbons). (3) Standard control circuit voltages. Volts 8 110 115 0 30 0 380 00 15 0 50/60 Hz B7 D7 E7 F7 FE7 M7 P7 U7 Q7 V7 N7 R7 Other voltages: please consult your Regional Sales Office. Dimensions: page /3 Schemes: page /35 /3

References (continued) TeSys enclosed starters Star-delta starters 7.5 to 75 kw, with isolating device 5338 Description The standard version comprises: b LE6 D09 D18: v 1 green Start button I, v 1 red Stop/Reset button O. b LE3 D36 D806: v no pushbuttons on cover Protection Power circuit Control circuit LE6 D09 and D1 1 3-pole isolating device + 1 additional pole LE6 D18 LE3 D806 1 3-pole isolating device + 1 circuit-breaker GB CB08 LE6 D1ppA0 Variants (pre-assembled) Description Application Suffix to be added to the starter reference (1) No pushbuttons on cover LE6 D09 D18 A0 5338 1 green Start button I 1 red Stop/Reset button O LE3 D36 D806 A06 1 blue Reset button R LE6 D09 LE3 D806 A05 1 neutral terminal LE6 D09 LE3 D806 A59 LE6 D1ppA05 Mechanical interlock Fitted as standard on starters LE6 D09 D18 LE3 D36 D806 A6 (1) Example: LE6 D09F7A0. Dimensions: page /3 Schemes: page /35 /33

Dimensions TeSys enclosed starters Star-delta starters 7.5 to 75 kw, with isolating device Dimensions LE6 D09 D18 LE3 D36 c1 38 330 186 31 190 367 195 87 5 31 c1 Standard version 175.5 Variant A0 167 Variant A05 175.5 LE3 D06 D806 a-75 31 b (1) b+57,5 b-50 b-75 xm8x5 c1 a-50 a a+57,5 LE3 a b c1 D06, D506 00 500 18 D806 500 700 69 (1) + 1 mm with blanking plugs. Knock-outs or blanking plugs for cable glands Type of enclosure At top At bottom PG ISO PG ISO LE6 D09 D18 x 0 or x 5 or x 3 or x 0 LE3 D36 1 x 1 1 x 3 x 13, x 16 and 1 x 1 LE3 D06 1 x 9 1 x 3 x 13, x 1 and 1 x 9 LE3 D506 1 x 36 1 x 0 x 13, x 9 and 1 x 36 x 0 or x 5 or x 3 or x 0 x 0, x 5 and 1 x 3 x 0, x 5 and 1 x 3 1 x 0, x 0 and x 3 LE3 D806 1 x 36 1 x 0 x 13 and 3 x 36 x 0 and 3 x 0 References : pages /3 and /33 Schemes : page /35 /3

Schemes TeSys enclosed starters Star-delta starters 7.5 to 75 kw, with isolating device Schemes LE6 D09 D18 Q1 1/L1 3/L 5/L3 6 A Q1 Q1 1 3 5 6 U1 V1 1 3 5 1 3 5 W1 O KM KM3 l KM 6 6 6 U V W U1 V1 W1 1 3 5 KM KM U V W 6 Recommended cabling for reversal of motor rotation (standard motor, viewed from shaft end) B KM3 A KM A KM3 A LE3 D36 D806 1/L1 3/L 5/L3 6 A Q1 F1 Q1 KM 1 3 KM3 6 5 1 3 U1 V1 W1 1 6 5 1 3 6 5 6 U V U1 V1 W1 W Remote Ð S1 control l 1 13 KM U V W 1 3 5 6 Recommended cabling for reversal of motor rotation (standard motor, viewed from shaft end) B KM KM3 A KM KM KM3 A A Connections A B 0 V, 30 V, 0 V LE6 D09 and D1 L3 Neutral LE6 D18 LE3 D806 L3 Neutral terminal 380 V, 00 V, 15 V, 0 V All products L3 L1 Other voltages LE6 D09 D18 Terminal 1 Terminal LE3 D36 D806 Direct connection References : pages /3 and /33 Dimensions : page /3 /35

References TeSys enclosed starters Replacement parts for starters without isolating device 500118_1 Heads for Start and Stop/Reset pushbuttons Description For use on Unit reference Weight kg Flush, green I (1) LE1 D09...D35 ZB5 AA331 0.018 50010_1 ZB5 AA331 Projecting, red O (1) LE1 D09...D35 ZB5 AL3 0.019 Adaptation kit for head ZB5 AL3 LE1 D09 and D1 LAD 9091 0.00 LE1 D18...D35 LAD 91810 0.003 ZB5 AL3 Heads for Reset pushbuttons Flush, blue R () LE1 D09...D35 ZB5 AA0 0.0 500117_1 + ZBA 639 (3) 0.001 Adaptation kit for head ZB5 AA0 + ZBA 639 LE1 D09 and D1 LAD 909 0.00 LAD 9091 LE1 or LE D18...D35 LAD 91810 0.003 LE3, LE6, LE or LE8 D09...D35 LAD 9T 0.00 500119_1 Heads for selector switches 3-position stay put LE1 D09...D35 ZB5 AD3 0.0 ZB5 ADp -position stay put LE1 D09...D35 ZB5 AD 0.0 50011_1 3-position spring return to centre LE1 D09...D35 ZB5 AD5 0.0 Contact blocks 1 N/O spring return LE1 D09...D35 ZEN L1111 0.010 ZEN L1111 1 N/C spring return LE1 D09...D35 ZEN L111 0.010 5001_1 Mounting for contact block LE1 D09 and D1 LAD 90909 0.008 LEp D18...D35 () LAD 91809 0.01 LAD 91809 (1) Remember to order adaptation kit LAD 9091 or LAD 91810, depending on size. () Remember to order adaptation kit LAD 909. (3) Sold in lots of 10. () LE1, LE, LE3, LE, LE6 or LE8. /36

References (continued) TeSys enclosed starters Replacement parts for starters without isolating device 810175 Empty enclosures for D.O.L. starters without isolating device Designed for use with Head(s) mounted on cover Reference Weight kg LE1 D09 and D1 Without DE1 DS1A0 0.300 1 flush blue head R DE1 DS1A05 0.300 DE1 DS1A0 810176 1 flush green head I 1 projecting red head O DE1 DS1 0.300 1 flush blue head R 1 switch DE1 DS13 0.300 DE1 DS1A05 810173 LE1 D18...D35 Without DE1 DSA0 0.500 1 flush blue head R DE1 DSA05 0.500 DE1 DS1 810178 1 flush green head I 1 projecting red head O DE1 DS 0.500 1 flush blue head R 1 switch DE1 DS3 0.500 DE1 DS13 /37

References starters Star-delta starters (1) 90 to 375 kw, without isolating device 533866 Star-delta starters Maximum operating rate: 1 starts/hour. Maximum starting time: 0 seconds Standard power ratings of squirrel cage motors Mains voltage - delta connection Basic reference, to be completed by adding the voltage code () (3) Weight 0 V 380 V 15 V 0 V kw kw kw kw kg 90 160 160 185 LE3 F185pp 31.00 100 00 00 0 LE3 F5pp 33.000 110 0 0 50 LE3 F65pp 50.800 533867 160 80 80 315 LE3 F330pp 80.000 185 315 355 375 LE3 F00pp 8.000 Specifications Enclosure LE3 F185 F00 Metal, degree of protection IP 559 No pushbuttons on cover LE3 F185 F00 LE3 Fppppp Connections LE3 F185 F00 Pre-wired power and control circuit connections Variants (pre-assembled) Description 1 green Start button I 1 red Stop/Reset button O For use on LE3 F185 F00 Suffix to be added to the starter reference() A06 (1) Overload protection must be provided by a thermal overload relay, to be ordered separately. Select appropriate overload relay for setting at 0.58 of the full load rated motor current, see pages 6/8 and 6/9. () Standard control circuit voltages. Volts 8 110 0/30 30 0 380/00 00 15 50/60 Hz E7 F7 M7 P7 U7 Q7 V7 N7 For other voltages, see pages 5/118 to 5/15. (3) LC1 F185 and F5: contactors fitted with LX9 F coils, LC1 F65 F00: contactors fitted with LX1 F coils. () Example: LE3 F185M7A06. Other versions Possible combinations of variants. Please consult your Regional Sales Office. Dimensions : page /39 Schemes : page /39 /38