Safety detection solutions

Size: px
Start display at page:

Download "Safety detection solutions"

Transcription

1 Presentation, actuator operated etal, types CS A, CS B, CS C and CS E Plastic, double insulated, turret head, types CS P or CS PA or CS TA and CS TE etal, types CS A, CS B, CS C, CS E with or without locking of the actuator Plastic, types CS P, CS PA CS TA, CS TE Pages /0 to / with or without locking of the actuator Pages / and / to / Environment characteristics Guard switch type CS A, CS B, CS C, CS E (metal) CS P, CS PA, CS TA, CS TE (plastic) Conformity to standards Products EC/EN 0--, UL 0, CSA C- n achine assemblies EC/EN 00-, EN 0/S, EN/S 00 Product certifications UL, CSA UL, CSA (c UL for CS P) Protective treatment Standard version: TC Ambient air temperature For operation C (- + 0 C for CS E and C for CS TE) For storage C (- + 0 C for CS P) Vibration resistance gn (0 00 Hz) conforming to EC/EN 00-- ( gn (0 Hz) for CS P) Shock resistance 0 gn (duration ms) conforming to EC/EN 00-- (0 gn (duration ms) for CS P) Electric shock protection Class conforming to EC/EN 0 Class conforming to EC/EN 0 Degree of protection P conforming to EC/EN 0 and EC/EN 0-- () Cable entry entry (CS A, CS B, CS C) or entries (CS E) tapped for n (Pg.) cable gland, tapped 0 or tapped /" NPT entry (CS PA and CS TE) or entries (CS TA) tapped for n (Pg ) cable gland, tapped or tapped /" NPT (with adaptor) for CS TA and CS TE Connecting cable Pre-cabled, either x 0. mm or x 0. mm (CS P) aterials CS A/B/C/E Zamak case CS P/PA/TA/TE/PL/TL/PR/TR Polyamide PA fibreglass impregnated enclosure Actuators (all types): steel C0, surface treated () Live parts of these switches are protected against the penetration of dust and water. However, when installing take all necessary precautions to prevent the penetration of solid bodies, or liquids with a high dust content, into the actuator aperture. Not recommended for use in saline atmospheres. 0 /

2 Characteristics, actuator operated etal, types CS A, CS B, CS C and CS E Plastic, double insulated, turret head, types CS P or CS PA or CS TA and CS TE Contact block characteristics Rated operational characteristics Conventional thermal current in enclosure and contact, slow break CS A, CS B, CS C, CS TA, CS PA: a AC-, A00: Ue = 0 V, e = A or Ue = 0 V, e = A CS E, CS TE: a AC-, B00: Ue = 0 V, e =. A or Ue = 0 V, e = A CS P: a AC-, C00: Ue = 0 V, e = 0. A or Ue = 0 V, e =. A All models: c DC-, Q00: Ue = 0 V, e = 0. A or Ue = V, e = 0. A conforming to EC/EN 0-- contact, snap action CS PA: a AC-, A00: Ue = 0 V, e = A; the = 0 A c DC-, Q00: Ue = 0 V, e = 0. A or Ue = V, e = 0. A conforming to EC/EN 0-- contact, snap action CS PA: a AC-, B00: Ue = 0 V, e =. A; the = A c DC-, R00: Ue = 0 V, e = 0. A or Ue = V, e = 0. A conforming to EC/EN 0-- CS A, CS B, CS C, CS PA ( & slow break contact and snap action contact versions) CS E, CS TE, CS PA ( snap action contact version): the = A CS P: the =. A Rated insulation voltage and contact contacts (CS A, CS B, CS C, CS E, CS TA), contacts (CS PA, CS TE), and contacts (CS P): Ui = 00 V conforming to EC/EN 0-; Ui = 00 V conforming to UL 0, CSA C- n contact CS PA and CS TE: Ui = 00 V degree of pollution conforming to EC 0- Ui = 00 V conforming to UL 0, CSA C- n Rated impulse withstand voltage and contact contacts (CS A, CS B, CS C, CS E, CS TA), contacts (CS PA, CS TE), and contacts (CS P): Uimp = kv conforming to EC/EN 0-- contact CS PA: Uimp = kv conforming to EC/EN 0-- Positive operation N/C contact(s) with positive opening operation conforming to EC/EN 0--, Section Resistance across terminals y 0 mω conforming to EC/EN 0-- Short-circuit protection and contact contacts (CS A, CS B, CS C, CS E, CS TA), contacts (CS PA, CS TE), and contacts (CS P): 0 A cartridge fuse type gg (gl) contact CS PA: A cartridge fuse type gg (gl) Connection Pre-cabled x 0. mm or x 0. mm (CS P), PVC Electrical durability Screw clamp terminals Conforming to EC/EN 0-- Appendix C. Utilisation categories AC- and DC-. aximum operating rate: 00 operating cycles/hour. Load factor: 0. contact, snap action CS PA, CS TA: Clamping capacity, min: x 0. mm, max: x. mm and contact contacts (CS A, CS B, CS C, CS E, CS TA), contacts (CS PA, CS TE): Clamping capacity, min: x 0. mm, max: x. mm with or without cable end contact CS PA: clamping capacity, min: x 0. mm, max: x mm or x 0. mm nly applicable to CS P: Conforming to EC/EN 0-- Appendix C. Utilisation categories AC- and DC-. aximum operating rate: 00 operating cycles/hour. a.c. supply a 0/0 Hz o inductive circuit illions of operating cycles snap action contact version contact version CS A/B/C/E/TA and slow break contact version 0, 0 V 0/00 V V V the illions of operating cycles 0, 0, the 0 V // V 0 V 0, 0, 0 Current in A d.c. supply c Voltage V 0 Voltage V 0 Power broken in W for o W 0 o W million operating cycles. For ES Pp on a or c, N/C and N/ contacts simultaneously loaded to the values shown with reverse polarity. a.c. supply a 0/0 Hz o inductive circuit d.c. supply c Power broken in W for million operating cycles. illions of operating cycles 0, 0, 0 Current in A snap action contact version CS PA slow break contact version CS PA 0, 0 V 0/00 V V the V 0, 0, 0 Current in A Current in A Voltage V 0 Voltage V 0 o W o W illions of operating cycles 0, 0, the // V 0 V 0 V 0, 0, 0 0 /

3 References, characteristics etal, turret head (), types CS A, CS B, CS C and CS E or cable entries 0 x. () Type of switch Without locking of actuator With locking of actuator, manual unlocking () LED indication on opening of N/C contacts Without orange LED z / V Without References of switches without actuator ( N/C contact with positive opening operation) -pole N/C + N/ + N/ ( N/ staggered) slow break () -pole N/C + N/C + N/ (N/ staggered) slow break () Without CS A0 CS A CS B0 CS C0 CS A0 CS A CS B0 CS C0 -pole N/C + N/C + N/C slow break () CS A0 Weight (kg) Complementary characteristics not shown under General characteristics (/) Actuation speed Resistance to forcible withdrawal of actuator echanical durability aximum operating rate inimum force for extraction of actuator Cable entry aterials References of actuators aximum: 0. m/s, minimum: 0.0 m/s CS B and CS C: 00 N; CS E: 000 N CS A and CS E: > million operating cycles CS B and CS C: 0. million operating cycles For maximum durability: 00 operating cycles per hour u 0 N CS A, CS B, CS C: cable entry. CS E: cable entries Entries tapped 0 x. for S cable gland. Clamping capacity to mm Body: zamak. Head: zamak. Safety screws: -lobe torque. Protective plate: steel. 0 Description Straight actuator Actuator with wide fixing Pivoting actuator Latch for sliding doors (Padlockable in open position) For guard switches CS A, B, C, E CS Z0 CS Z0 CS Z0 CS Z0 Weight (kg) () Head adjustable in 0 steps throughout 0. Blanking plug for operating head slot included with switch. () For cable entries tapped for n (Pg.) cable gland, replace the last number in the reference () by (see page /). Example: CS A0 becomes CS A0. () Unlocking by pushbutton for CS Bppp and by key operated lock for CS Cppp. () Schematic diagrams shown represent the contact states whilst the actuator is inserted in the head of the switch. ther versions: please consult your Regional Sales ffice. page / and / page / /0

4 References, characteristics (continued) etal, turret head (), types CS A, CS B, CS C and CS E or cable entries 0 x. () Type of switch With interlocking, locking by solenoid Type of interlocking Locking on de-energisation and unlocking on energisation of solenoid (). To order a guard switch with locking on energisation and unlocking on de-energisation of the solenoid, replace the nd number () by in the references shown below. Example: CS E becomes CS E.. LED indication Supply voltage of solenoid range LED: guard open signalling. Green LED: guard closed and locked signalling. a or c V (0/0 Hz on a) a or c V (0/0 Hz on a) a or c 0/0 V () (0/0 Hz on a) a or c 0/0 V () (0/0 Hz on a) Type of contact on solenoid N/C + N/ N/C N/C + N/ N/C + N/ N/C N/C + N/ N/C References of switches without actuator ( N/C contact with positive opening operation) -pole N/C + N/ + N/ ( N/ staggered) slow break () CS E CS E -pole N/C + N/C + N/ (N/ staggered) slow break () CS E CS E CS E CS E CS E CS E -pole N/C + N/C + N/C slow break () CS E () CS E () CS E () Weight (kg) Solenoid characteristics Load factor 00% Rated operational voltage a or c V a or c V a or c V a or c 0/0 V Voltage limits - 0%, + 0% of the rated operational voltage (including ripple on c) conforming to EC/EN 0- Service life Consumption LED indicator characteristics hours nrush: 0 VA. Sealed: 0 VA a or c 0/0 V Rated insulation voltage 0 V conforming to EC/EN 0-0 V conforming to EC/EN 0- Current consumption ma ma Rated operational voltage a or c / V a 0/0 V Voltage limits a or c 0... V (including ripple) a... V (including ripple) Service life hours hours Protection against overvoltages Yes Yes () Head adjustable in 0 steps throughout 0. Blanking plug for operating head slot included with switch. () For cable entries tapped for n (Pg.) cable gland, replace the last number in the reference () by (see page /). Example: CS E becomes CS E. () A key operated lock enables forced opening of the interlocking mechanism, by authorised personnel, allowing withdrawal of the actuator and subsequent opening of the N/C safety contacts. () For use on c 0/0 V or c 0/0 V, remove the LED indicator module. () Schematic diagrams shown represent the contact states whilst the actuator is inserted in the head of the switch. () Switches supplied with a single green LED. 0 ther versions: please consult your Regional Sales ffice. page / and / page / /

5 References, characteristics etal, turret head (), types CS A, CS B, CS C and CS E Cable entries tapped for n (Pg.) cable gland Type of switch Without locking of actuator With locking of actuator, manual unlocking () LED indication on opening of N/C contacts Without orange LED z / V orange LED a 0/0 V Without orange LED z / V References of switches without actuator ( N/C contact with positive opening operation) -pole N/C + N/ + N/ ( N/ staggered) slow break () -pole N/C + N/C + N/ (N/ staggered) slow break () Without orange LED z / V CS A0 CS A CS A CS B0 CS B CS C0 CS C CS A0 CS A CS A CS B0 CS C0 -pole N/C + N/C + N/C slow break () CS A0 CS B0 CS C0 Weight (kg) Complementary characteristics not shown under General characteristics (/) Actuation speed Resistance to forcible withdrawal of actuator echanical durability aximum operating rate inimum force for extraction of actuator Cable entry aterials References of actuators aximum: 0. m/s, minimum: 0.0 m/s CS B and CS C: 00 N; CS E: 000 N CS A and CS E: > million operating cycles CS B and CS C: 0. million operating cycles For maximum durability: 00 operating cycles per hour u 0 N CS A, CS B, CS C: cable entry. CS E : cable entries Entries tapped for n cable gland conforming to NF C -00 (DN Pg.). Clamping capacity to mm Body: zamak. Head: zamak. Safety screws: -lobe torque. Protective plate: steel. 0 Description Straight actuator Actuator with wide fixing Pivoting actuator Latch for sliding doors (Padlockable in open position) For guard switches CS A, B, C, E CS Z0 CS Z0 CS Z0 CS Z0 Weight (kg) () Head adjustable in 0 steps throughout 0. Blanking plug for operating head slot included with switch. () Unlocking by pushbutton for CS Bppp and by key operated lock for CS Cppp. () Schematic diagrams shown represent the contact states whilst the actuator is inserted in the head of the switch. ther versions: please consult your Regional Sales ffice. page / and / page / /

6 References, characteristics (continued) etal, turret head (), types CS A, CS B, CS C and CS E Cable entries tapped for n (Pg.) cable gland Type of switch With interlocking, locking by solenoid Type of interlocking Locking on de-energisation and unlocking on energisation of solenoid (). To order a guard switch with locking on energisation and unlocking on de-energisation of the solenoid, replace the nd number () by in the references shown below. Example: CS E becomes CS E. LED indication Supply voltage of solenoid range LED: guard open signalling. Green LED: guard closed and locked signalling. a or c V (0/0 Hz on a) a or c V (0/0 Hz on a) a or c 0/0 V () (0/0 Hz on a) a or c 0/0 V () (0/0 Hz on a) Type of contact on solenoid N/C + N/ N/C N/C + N/ N/C N/C + N/ N/C N/C + N/ N/C References of switches without actuator ( N/C contact with positive opening operation) -pole N/C + N/ + N/ ( N/ staggered) slow break () -pole N/C + N/C + N/ (N/ staggered) slow break () -pole N/C + N/C + N/C slow break () CS E CS E CS E CS E CS E CS E CS E CS E CS E CS E CS E CS E CS E () CS E () CS E Weight (kg) Solenoid characteristics Load factor 00% () CS E CS E Rated operational voltage a or c V a or c V a or c 0/0 V a or c 0/0 V Voltage limits - 0%, + 0% of the rated operational voltage (including ripple on c) conforming to EC/EN 0- Service life hours Consumption nrush: 0 VA. Sealed: 0 VA LED indicator characteristics Rated insulation voltage 0 V conforming to EC/EN 0-0 V conforming to EC/EN 0- Current consumption ma ma Rated operational voltage a or c / V a 0/0 V Voltage limits a or c 0... V (including ripple) a... V (including ripple) Service life hours hours Protection against overvoltages Yes () Head adjustable in 0 steps throughout 0. Blanking plug for operating head slot included with switch. () A key operated lock enables forced opening of the interlocking mechanism, by authorised personnel, allowing withdrawal of the actuator and subsequent opening of the N/C safety contacts. () For use on c 0/0 V or c 0/0 V, remove the LED indicator module. () Schematic diagrams shown represent the contact states whilst the actuator is inserted in the head of the switch. () Switches supplied with a single green LED. ther versions: please consult your Regional Sales ffice. Yes 0 page / and / page / /

7 References, characteristics etal, turret head (), types CS A, CS B, CS C and CS E Cable entries tapped / NPT Type of switch Without locking of actuator With locking of actuator, manual unlocking () LED indication on opening of N/C contacts Without orange LED z / V orange LED a 0/0 V Without orange LED z / V orange LED a 0/0 V Without References of switches without actuator ( N/C contact with positive opening operation) -pole N/C + N/ + N/ ( N/ staggered) slow break () CS A0 CS A CS B0 -pole N/C + N/C + N/ (N/ staggered) slow break () CS A0 CS A CS A CS B0 CS B CS B CS C0 -pole N/C + N/C + N/C slow break () CS A0 CS B0 CS C0 Weight (kg) Complementary characteristics not shown under General characteristics (page /) Actuation speed Resistance to forcible withdrawal of actuator echanical durability aximum operating rate inimum force for extraction of actuator aximum: 0. m/s, minimum: 0.0 m/s CS B and CS C: 00 N; CS E: 000 N CS A and CS E: > million operating cycles CS B and CS C: 0. million operating cycles For maximum durability: 00 operating cycles per hour u 0 N Cable entry aterials References of actuators CS A, CS B, CS C: cable entry CS E: cable entries Entries tapped for / NPT (USAS B-) conduit Body: zamak. Head: zamak. Safety screws: -lobe torque. Protective plate: steel. Description Straight actuator Actuator with wide fixing Pivoting actuator Latch for sliding doors (Padlockable in open position) For guard switches CS A, B, C, E CS Z0 CS Z0 CS Z0 CS Z0 Weight (kg) () Head adjustable in 0 steps throughout 0. Blanking plug for operating head slot included with switch. () Unlocking by pushbutton for CS Bppp and by key operated lock for CS Cppp. () Schematic diagrams shown represent the contact states whilst the actuator is inserted in the head of the switch. 0 ther versions: please consult your Regional Sales ffice. page / and / page / /

8 References, characteristics (continued) etal, turret head (), types CS A, CS B, CS C and CS E Cable entries tapped / NPT Type of switch With interlocking, locking by solenoid Type of interlocking Locking on de-energisation and unlocking on energisation of solenoid (). To order a guard switch with locking on energisation and unlocking on de-energisation of the solenoid, replace the nd number () by in the references shown below. Example: CS E becomes CS E. LED indication Supply voltage of solenoid range LED: guard open signalling. Green LED: guard closed and locked signalling. a or c V (0/0 Hz on a) a or c 0/0 V () (0/0 Hz on a) Type of contact on solenoid N/C + N/ N/C N/C + N/ N/C References of switches without actuator ( N/C contact with positive opening operation) -pole N/C + N/ + N/ ( N/ staggered) slow break () CS E CS E -pole N/C + N/C + N/ (N/ staggered) slow break () CS E CS E CS E CS E -pole N/C + N/C + N/C slow break () CS E () Weight (kg).0 Solenoid characteristics Load factor 00 % Rated operational voltage a or c V a or c 0/0 V Voltage limits - 0%, + 0% of the rated operational voltage (including ripple on c) conforming to EC/EN 0- Service life Consumption LED indicator characteristics heures nrush: 0 VA. Sealed: 0 VA Rated insulation voltage 0 V conforming to EC/EN 0-0 V conforming to EC/EN 0- Current consumption ma ma Rated operational voltage a or c / V a 0/0 V Voltage limits a or c 0... V (including ripple) a... V (including ripple) Service life hours hours Protection against overvoltages Yes Yes () Head adjustable in 0 steps throughout 0. Blanking plug for operating head slot included with switch. () A key operated lock enables forced opening of the interlocking mechanism, by authorised personnel, allowing withdrawal of the actuator and subsequent opening of the N/C safety contacts. () For use on c 0/0 V, remove the LED module. () Schematic diagrams shown represent the contact states whilst the actuator is inserted in the head of the switch. () Switches supplied with a single green LED. ther versions: please consult your Regional Sales ffice. 0 page / and / page / /

9 References etal, turret head, types CS A, CS B, CS C and CS E 0 Separate components Description orange LED indicator module with cover, seal and fixing screws For use with CS A CS B CS C Supply voltage Reference Weight kg a or c / V CS Z 0.00 a 0/0 V CS Z 0.00 CS Zp 0 orange LED + green LED indicator module with cover + lock (), seal and fixing screws ( keys included for lock) CS Epp a or c / V CS Z 0. 0 () Lock incorporated as standard on guard switches CS E: key withdrawal in LCK and UNLCK positions. CS Zp Description Blanking plugs for operating head slot (Sold in lots of 0) Keys for interlock forced opening device (Sold in lots of 0) For use with CS A, CS B, C, CS E CS B, C, CS E Key withdrawal positions from lock Unit reference Weight kg CS Z 0.00 CS Z Padlocking device to prevent insertion of actuator, for up to padlocks (padlocks not included) CS A, CS B, C, CS E CS Z0 0.0 CS Z0 Description For use with Unit reference Weight kg /" NPT conduit adaptor (Sold in lots of ) CS A, CS B, CS C, CS E DE RA x. adaptor (Sold in lots of ) CS A, CS B, CS C, CS E DE RA pages / and / page / /

10 Dimensions etal, turret head, types CS A, CS B, CS C and CS E Dimensions CS Appp CS Bppp, CS Cppp, 0,, () tapped entry for cable gland () tapped entry for cable gland Ø: elongated holes Ø. x. Ø: elongated holes Ø. x. 0 x. adaptor /" NPT conduit adaptor CS Epppp DE RA0 DE RA0 (), () 0,, () = 0 = 0 () = 0 = 0, () 0 x. tapped entry () Pg. threaded shank () Tapped entry for /" NPT conduit () 0 x. threaded shank, () () () tapped entry for cable gland Ø: elongated holes Ø. x. = = () 0 References: pages /0 to / page / /

11 Dimensions (continued) etal, turret head, types CS A, CS B, CS C and CS E Dimensions (continued) CS Z0,, Adaptor shank () CS Z0,, == = = = = = 0 0, () Adaptor (included with actuator CS Z0) for replacing, without drilling additional fixing hole, a guard switch CK J with actuator ZCK Y0 by a guard switch CS A, B, C or E with actuator CS Z0. Ø: elongated holes Ø. x 0 Ø: elongated holes Ø. x 0 CS Z0 CS Z0 =,, 0 0 0,, Fixing axis % related to actuator. Ø: elongated holes Ø. x. perating radius required for actuator CS Z0 CS Z0 0 x 00 0 R = 000 R = 000 R = 000 R = 000 CS Z0 R =0, R = 00 0 R = minimum radius References: pages /0 to / page / /

12 Setting-up, schemes etal, turret head, types CS A, CS B, CS C and CS E Setting-up Functional diagrams CS pppp CS pppp CS pppp Contact operation G Contact closed H Contact open, - - -, G Unstable Schemes Note: These schemes are given as examples only, the designer must refer to the relevant safety standards for guidance Wiring to category conforming to EN -/ Wiring to category conforming to EN -/S - S - Example with -pole N/C + N/ + N/ contact and protection fuse to prevent shunting of the N/C contact, either by cable damage or by tampering. F () Example with -pole N/C + N/ + N/ contact with mixed redundancy of the contacts and the associated control relays. To activate K, it is necessary to remove and re-insert the actuator when the supply is switched on. F K K K K K K K K K K K H K () Signalling contact H: actuator not inserted indicator Wiring to category conforming to EN -/S -. Wiring method used in conjunction with Preventa safety module (The guard switch should be used in conjunction with a safety limit switch to give electrical/mechanical redundancy) ethod for machines with quick rundown time (low inertia) ethod for machines with long rundown time (high inertia) Locking or interlocking device based on the principle of redundancy and self-monitoring. The safety modules ensure these functions. PS PS VNE PS Locking of actuator and operation in positive mode associated with a safety module. nterlocking device for actuator fitted on guard and zero speed detection. 0 References: pages /0 to / pages / and / /

13 Schemes with solenoid interlocking etal, turret head, type CS E Wiring to category conforming to EN -/S - Wiring examples with protection fuse to prevent shunting of the N/C contact, either by cable damage or by tampering. Locking on de-energisation, N/C + N/ + N/ Locking on energisation, N/C + N/ + N/ CS Epp CS Epp F F () () () () E E G GN E E G GN () Solenoid () Solenoid () Auxiliary contact () Auxiliary contact E-E: Solenoid supply E-E: Solenoid supply -: Solenoid signalling contact -: Solenoid signalling contact -: Safety contact, available for redundancy -: Safety contact, available for redundancy -: LED (orange): actuator withdrawn -: LED (orange): actuator withdrawn -: LED (green): actuator inserted and locked -: LED (green): actuator inserted and locked -: Safety pre-wiring obligatory -: Safety pre-wiring obligatory Note: These schemes are given as examples only, the designer must refer relevant safety standards for guidance. 0 References: pages /0 to / pages / and / /0

14 Schemes (continued) with solenoid interlocking etal, turret head, type CS E Wiring to category conforming to EN -/S - Wiring examples with redundancy for the guard switch contacts, without monitoring or redundancy in the power circuit Locking on de-energisation, N/C + N/C + N/ Locking on de-energisation, N/C + N/C + N/ CS Epp CS Epp F F F F () () E E G GN K K K K K K K K () () E E G GN K K K K K K K K () Solenoid () Solenoid () Auxiliary contact () Auxiliary contact E-E: Solenoid supply E-E: Solenoid supply -: Solenoid signalling contact - and -: Solenoid signalling contacts - and -: Safety contacts, available for redundancy - and -: Safety contacts, available for redundancy -: LED (orange): actuator withdrawn -: LED (orange): actuator withdrawn -: LED (green): actuator inserted and locked -: LED (green): actuator inserted and locked -: Safety pre-wiring obligatory - and -: Safety pre-wiring obligatory Locking on energisation, N/C + N/C + N/ CS Epp F F () () K K E E K G GN K K K K K () Solenoid () Auxiliary contact E-E: Solenoid supply -: Solenoid signalling contact - and -: Safety contacts, available for redundancy -: LED (orange): actuator withdrawn -: LED (green): actuator inserted and locked -: Safety pre-wiring obligatory 0 References: pages /0 to / pages / and / /

15 References, characteristics (continued) Type of switch Plastic, turret head (), types CS PA, CS TA and CS TE or cable entries x. () With interlocking, locking by solenoid Type of interlocking Locking on de-energisation and unlocking on energisation of solenoid (). To order a guard switch with locking on energisation and unlocking on de-energisation of the solenoid, replace the nd number () by in the references shown below. Example: CS TE becomes CS TE. Supply voltage of solenoid a or c V (0/0 Hz on a) References of switches without actuator ( N/C contact with positive opening operation) -pole N/C + N/ () break before make slow break -pole N/C + N/C () slow break Weight (kg) 0.0 Solenoid characteristics Load factor 00 % Rated operational voltage CS TE CS TE a or c V Voltage limits - 0%, + 0% of the rated operational voltage (including ripple on c) conforming to EC/EN 0- Service life Consumption hours 0 VA max. References of actuators and guard retaining device Description Straight actuator Actuator with wide fixing () Pivoting actuator Right-angled actuator Guard retaining device () For guard switches CS PA, TA, TE CS Z CS Z CS Z CS Z CS Z CS Z Weight (kg) () Head adjustable in 0 steps throughout 0. Blanking plug for operating head slot included with switch. () For cable entries tapped for n (Pg ) cable gland, replace the last number in the reference () by (see page /). Example: CS TE becomes CS TE. () A special tool included with the guard switch enables forced opening of the interlocking mechanism, by authorised personnel, allowing withdrawal of the actuator and subsequent opening of the N/C safety contacts. () Schematic diagrams shown represent the contact states whilst the actuator is inserted in the head of the switch. () actuator lengths, CS Z: L = 0 mm, CS Z: L = mm. () nly for use with guard switches CS PA and CS TA (without the actuator centering device CS Z00), used in conjunction with actuators CS Z, CS Z or CS Z. ther versions: please consult your Regional Sales ffice. 0 page / and / page / /

16 References, characteristics (continued) Type of switch Plastic, turret head (), types CS PA, CS TA and CS TE Cable entries tapped for n (Pg ) cable gland With interlocking, locking by solenoid Type of interlocking Locking on de-energisation and unlocking on energisation of solenoid (). To order a guard switch with locking on energisation and unlocking on de-energisation of the solenoid, replace the nd number () by in the references shown below. Example: CS TE becomes CS TE. Supply voltage of solenoid a or c V (0/0 Hz on a) a or c 0 V (0/0 Hz on a) References of switches without actuator ( N/C contact with positive opening operation) -pole N/C + N/ () break before make slow break -pole N/ + N/C () make before break slow break -pole N/C + N/C () slow break a or c 0 V (0/0 Hz on a) CS TE CS TE CS TE CS TE CS TE CS TE CS TE Weight (kg) Solenoid characteristics Load factor 00 % Rated operational voltage a or c V a or c 0 V a or c 0 V Voltage limits - 0%, + 0% of the rated operational voltage (including ripple on c) conforming to EN/EC 0- Service life Consumption hours 0 VA max. References of actuators and guard retaining device Description Straight actuator Actuator with wide fixing () Pivoting actuator Right-angled actuator Guard retaining device () For guard switches CS PA, TA, TE CS Z CS Z CS Z CS Z CS Z CS Z Weight (kg) () Head adjustable in 0 steps throughout 0. Blanking plug for operating head slot included with switch. () A special tool included with the guard switch enables forced opening of the interlocking mechanism, by authorised personnel, allowing withdrawal of the actuator and subsequent opening of the N/C safety contacts. () Schematic diagrams shown represent the contact states whilst the actuator is inserted in the head of the switch. () nly for use with guard switches CS PA and CS TA (without the actuator centering device CS Z00), used in conjunction with actuators CS Z, CS Z or CS Z. () actuator lengths, CS Z: L = 0 mm, CS Z: L = mm. ther versions: please consult your Regional Sales ffice. 0 page / and / page / /

17 Dimensions Plastic, turret head, types CS PA, CS TA and CS TE Dimensions CS PAp, CS PAp CS PAp ,,, (), = 0/ = 0 0 () tapped entry for cable gland Ø: elongated holes Ø. x. on centres, holes Ø. on 0 centres CS TApp () 0, = 0/ = 0 () tapped entry for /" NPT conduit Ø: elongated holes Ø. x. on centres, holes Ø. on 0 centres CS TEpppp 0 0 (),,, () 0, 0/ 0,, () 0 0/ 0 0 () tapped entries for cable gland or /" NPT conduit adaptor () elongated holes Ø. x. on centres, holes Ø. on 0 centres () elongated holes Ø. x. /" NPT conduit adaptor x. adaptor Actuator centering device DE RA0 DE RA0 CS Z00 () Tapped entry for /" NPT conduit () Pg threaded shank () () x. tapped entry () Pg threaded shank () tapped entry for cable gland or /" NPT conduit adaptor Ø: elongated holes Ø. x. on centres, holes Ø. on 0 centres,,,,,,,,, x Ø, x Ø References: pages / to / page / /

18 Schemes (continued) Plastic, turret head, type CS TE Schemes (continued) Wiring to category conforming to EN -/S - Wiring examples with protection fuse to prevent shunting of the N/C contact, either by cable damage or by tampering Locking on de-energisation Locking on energisation N/C + N/ CS TEpp N/C + N/ CS TEpp F F () () () () () () E E E E () Solenoid () Solenoid () Auxiliary contact () Auxiliary contact E-E: Solenoid supply E-E: Solenoid supply -: Safety contact, available for redundancy or signalling -: Safety contact, available for redundancy or signalling Wiring to category conforming to EN -/S - Wiring examples with redundancy for the guard switch contacts, without monitoring Locking on de-energisation Locking on energisation N/C + N/C CS TEpp N/C + N/C CS TEpp F () F K K F () F K K () () () () E E K K E E K K K K K K K K K K () Solenoid () Solenoid () Solenoid auxiliary contact () Solenoid auxiliary contact E-E: Solenoid supply E-E: Solenoid supply -: Safety contact, available for redundancy -: Safety contact, available for redundancy 0 References: pages / to / pages / and / /

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil Product data sheet Characteristics LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

Safety automation solutions

Safety automation solutions Operating principle, characteristics Preventa safety s types XPS AV,, For and switch monitoring Operating principle Safety s XPS AV, and are used for monitoring circuits conforming to standards EN/ISO

More information

Pendant control stations 6

Pendant control stations 6 Characteristics 6 Environment Conformity to standards EN/IEC 6097-5-1 EN/IEC 600-, UL 508, CSA C- n EN/IEC 6097-5-5 and EN/ISO 850 for versions with trigger action Emergency stop Product certifications

More information

Safety dialogue solutions

Safety dialogue solutions General Presentation Emergency stop trip wire switches Emergency stop trip wire switches are designed to: b avert hazards (dangerous phenomena) at the earliest possible moment, or to reduce risks which

More information

RM4TG20 three-phase network control relay RM4-T - range 200..500 V

RM4TG20 three-phase network control relay RM4-T - range 200..500 V Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking

More information

HS5D. Miniature Interlock Switches First in. Head Removal Detection Function for Safer Performance. First in. the Industry.

HS5D. Miniature Interlock Switches First in. Head Removal Detection Function for Safer Performance. First in. the Industry. y HS5D First in the Industry Miniature Interlock Switches First in the Industry Head Removal Detection Function for Safer Performance (*based on IDEC research, July 09) New Generation Miniature Interlock

More information

RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters

RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters Characteristics multifunction voltage control relay RM35-U - range 15..600 V Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main

More information

Series 8146/5-V37 and Series 8150/5-V37

Series 8146/5-V37 and Series 8150/5-V37 www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection

More information

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage

More information

48 SERIES Relay interface modules 10 A

48 SERIES Relay interface modules 10 A 48 Relay interface modules 10 A 1 CO relay interface modules, mm wide Ideal interface for PLC and electronic systems Type 48.P3 1 CO 10 A s Type 48.31 1 CO 10 A s AC coils or DC sensitive coils Supply

More information

R.C.C.B. s two-pole LEXIC

R.C.C.B. s two-pole LEXIC 87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s two-pole LEXIC 089 06/09/10/11/12/15/16/17/18/ 27/28/29/30/35, CONTENTS PAGES 1. Electrical and mechanical characteristics...

More information

Safety technique. Emergency stop module BO 5988 safemaster

Safety technique. Emergency stop module BO 5988 safemaster Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1

More information

Electronic overload relay EF19 and EF45

Electronic overload relay EF19 and EF45 Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor

More information

48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0.

48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0. 48 Series - Relay interface modules 8 A Features 48.12 2 Pole Safety relay interface modules, 15.8 mm wide 48.12-2 Pole 8 A (screw terminal) DC sensitive coils Relay with forcibly guided contacts according

More information

Electronic overload relay EF65, EF96 and EF146

Electronic overload relay EF65, EF96 and EF146 Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays.

More information

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101433D0201 28/03/11 NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits.

More information

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of

More information

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils

More information

Preventa Machine Safety Products

Preventa Machine Safety Products Preventa Machine Safety Products Catalog 2009 200 Supplement Safety Relay Modules 2 Contents Preventa safety relay modules Selection guide 2 Electrical Ratings 6 Types XPSAC and XPSAXE For Emergency stop

More information

3/2-way Solenoid Valve, direct-acting, NC or NO

3/2-way Solenoid Valve, direct-acting, NC or NO 3/2-way Solenoid Valve, direct-acting, NC or NO Electrical connection cable plug, Form A With or without manual override as standard Threaded port and sub-base s Impulse optional Type 6014 can be combined

More information

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application 33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection

More information

A good connection. International approvals.

A good connection. International approvals. E X - P L U G S A N D R E C E P T A C L E S A to A Plastic version for Zone and Zone A good connection Providing electrical energy there, where it is most needed even in hazardous areas for the Zones,,

More information

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Product datasheet Characteristics TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus

More information

Safe switching and monitoring Solenoid Interlocks

Safe switching and monitoring Solenoid Interlocks Safe switching and monitoring Solenoid Interlocks Solenoid locking switches are used on sliding, hinged and removable guard doors that must be closed and locked for operator safety. It is a two part system

More information

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear Mini Motor Contactor J7KNA ) Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN-rail) Range from 4 to 5.5 (AC 3, 380/415V) 4 -main pole version (4 AC

More information

AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101403D0201 24/03/11 AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF09(Z) contactors are used for controlling power circuits

More information

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection

More information

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description Photoelectrics, Background Suppression reflective with IR light Main features Description The PD30ET... stainless steel sensors are built with high-quality materials and designed for harsh environments.

More information

Micro Contactors. Micro Contactor Relays. Micro Contactors With Solder Pins. Coil voltages. Micro Reversing Contactor. Technical Data.

Micro Contactors. Micro Contactor Relays. Micro Contactors With Solder Pins. Coil voltages. Micro Reversing Contactor. Technical Data. Micro Contactors Micro Contactor Relays 0 Micro Contactors Micro Contactors With Solder Pins Coil voltages Micro Reversing Contactor 3 Technical Data 4 Dimensions 8 9 Micro Contactor Relays 4pole C Operated

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided

More information

49 Series - Relay interface modules 8-10 - 16 A. Features

49 Series - Relay interface modules 8-10 - 16 A. Features Features 1 & 2 Pole relay interface modules 5 µm Gold plate contacts for low level switching capability 49.31-50x0-1 Pole 10 A (screw terminal) 49.52-50x0-2 Pole 8 A (screw terminal) 49.72-50x0-2 Pole

More information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC

More information

Cross-beam scanning system to detect slim objects. 100 mm 3.937 in

Cross-beam scanning system to detect slim objects. 100 mm 3.937 in 891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC

More information

Plug and Socket Devices CES 63 A Series 8579

Plug and Socket Devices CES 63 A Series 8579 www.stahl.de > Switch socket / plug 63 A > Large switch handle with clear switch position indication padlockable in 0- and I-position > Low insertion and withdrawal forces through individually encapsulated

More information

Electro-pneumatic control valves

Electro-pneumatic control valves Electropneumatic control valves 7 Miniature solenoid valves for alternating current Conform to the Low Voltage Directive or mounting on subbase or footprint in accordance with CNOMO recoendation E 066120N

More information

Bimetallic Overload Relay Specifications

Bimetallic Overload Relay Specifications Technical Data Bimetallic Overload Relay Specifications Bulletin Number 193K, 193T1 Topic Page Product Overview 2 Standards compliance and Certifications 2 General Specifications 193K 3 Approximate Dimensions

More information

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only

More information

Manual Motor Starter MS 116 up to 16 A Technical Data

Manual Motor Starter MS 116 up to 16 A Technical Data Manual Motor Starter MS 116 up to 16 A Technical Data Type MS 116 Standards: Major International IEC 60 947-4-1 / IEC 60 947-2 and European Standards EN 60 947-4-1 / EN 60 947-2 Approvals, Certificates

More information

D4JL. Guard Lock Safety-door Switch. World's Top * Holding Force of 3,000 N. Features

D4JL. Guard Lock Safety-door Switch. World's Top * Holding Force of 3,000 N. Features Guard Lock Safety-door Switch D4JL CSM_D4JL_DS_E_4_1 World's Top * Holding Force of 3,000 N *For plastic models, as of May 2008 Two safety circuits and two monitor contacts provide an array of monitoring

More information

SKR - industry relay

SKR - industry relay SKR - industry relay the universal relay SKR the time module STM the socket The strengths of the SKR industry relay lie in the mature and thoughtout construction. Over-average contact safety and life time,

More information

Manual motor starter MS116

Manual motor starter MS116 Data sheet Manual motor starter MS116 Manual motor starters are electromechanical devices for motor and circuit protection. These devices offer local motor disconnect means, manual ON/ OFF control, and

More information

Technicaldata General

Technicaldata General Currenttransformer-operatedoverloadrelay,60-90A,1N/O+1N/C Partno. ZW7-90 Articleno. 002618 CatalogNo. XTOT090C3S Deliveryprogramme Product range ZW7 current transformer-operated overload relays Description

More information

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications. Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description

More information

Thermal-Magnetic Circuit Breaker 3120-...-M1-..

Thermal-Magnetic Circuit Breaker 3120-...-M1-.. Thermal-Magnetic Circuit Breaker -...-M-.. Description Single or two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 34). The addition of a magnetic tripping

More information

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN 60204-1, VDE 0113 Part 1

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN 60204-1, VDE 0113 Part 1 MainswitchSurfacemounting Partno. P3-63/I4/SVB Articleno. 207343 CatalogNo. SP3-063-I4CRQ IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual

More information

D-Line Contactors, Overload Relays and Accessories

D-Line Contactors, Overload Relays and Accessories D-Line Contactors, Overload Relays and Accessories Class 850 CONTENTS Description......................................................Page General Information...............................................

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2... Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast

More information

ADM1TE 5/30A DIN rail single phase two wire energy meter

ADM1TE 5/30A DIN rail single phase two wire energy meter ADMTE 5/30A DIN rail single phase two wire energy meter. Safety instruction.2 Foreword.3 Performance criteria.4 Specifications.5 Basic errors.6 Description.7 Dimensions.8 Installation.9 Operating.0 Troubleshooting.

More information

ZCK-E65 ZCK-Y51 ZCK-Y71 ZCK-Y61 ZCK-E09 (1) ZCK-E05 ZCK-J404H29

ZCK-E65 ZCK-Y51 ZCK-Y71 ZCK-Y61 ZCK-E09 (1) ZCK-E05 ZCK-J404H29 ZCK-E ZCK-E1 ZCK-Y ZCK-Y9 ZCK-E64 ZCK-E6 ZCK-Y1 ZCK-Y3 ZCK-E63 ZCK-Y91 ZCK-E6 ZCK-Y81 ZCK-E69 ZCK-Y71 ZCK-E67 ZCK-E9 (1) ZCK-Y61 ZCK-Y41 ZCK-Y43 ZCK-E6 ZCK-E8 ZCK-Y ZCK-Y ZCK-E619 ZCK-Y11 ZCK-E ZCK-E66

More information

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

DRM75A 230V 20/100A DIN rail single phase two wire energy meter DRM75A 230V 20/100A DIN rail single phase two wire energy meter 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Description 1.7 Dimensions 1.8 Installation

More information

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply) transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control

More information

Circuit Breakers. NRC Series. NRC Series. 900 www.idec.com

Circuit Breakers. NRC Series. NRC Series. 900 www.idec.com Switches & Pilot Lights Display Lights NRC series circuit breakers offer circuit protection which is far superior to using fuses in applications containing relay circuits, motor circuits, heater circuits,

More information

Technical catalogue. Modular DIN rail components Installation contactors

Technical catalogue. Modular DIN rail components Installation contactors Technical catalogue Modular DIN rail components Installation contactors Installation Contactors Overview... ESB Installation Contactors 0 A / AC-/AC-7a ESB0...4 4 A / AC-/AC-7a ESB4...5 40 A / AC-/AC-7a

More information

HERZ-Thermal Actuators

HERZ-Thermal Actuators HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01

More information

1 pole, 16 A Screw terminal connection 35 mm rail (EN 60715) mounting. 2 pole, 8 A Screw terminal connection 35 mm rail (EN 60715) mounting

1 pole, 16 A Screw terminal connection 35 mm rail (EN 60715) mounting. 2 pole, 8 A Screw terminal connection 35 mm rail (EN 60715) mounting Series - Relay interface modules 8-10 - 16 A Features.01.02 1 & 2 pole relay interface modules, screw terminal socket, mm wide. Ideal interface for PL and electronic systems.01-1 Pole 16 A.02-2 Pole 8

More information

Directory chapter 02 - DIN Power (to 6 A) Types D, E, F, FM, 2F, F9, interface connectors I/U 02. 01. Technical characteristics types D and E... 02.

Directory chapter 02 - DIN Power (to 6 A) Types D, E, F, FM, 2F, F9, interface connectors I/U 02. 01. Technical characteristics types D and E... 02. Directory chapter 02 - () Types D, E, F, FM, 2F, F9, interface connectors I/U Page Technical characteristics types D and E.............................. 02.10 Type D connectors.................... 02.11

More information

RY2 miniature industrial relays

RY2 miniature industrial relays 6 RY2 Relays of general application For plug-in sockets, 35 mm rail mount acc. to PN-EN 60715 or on panel mounting Flat insert connectors - faston x 0,5 mm Recognitions, certifications, directives: RoHS,

More information

SICONT Limit Switches Type 3SE3 upto 500 VAC, 600 VDC, 10A

SICONT Limit Switches Type 3SE3 upto 500 VAC, 600 VDC, 10A s SICONT Limit Switches Type 3SE3 upto 500 VAC, 600 VDC, 10A Introduction The technical and descriptive information on the function, construction and selection of the new types of 3SE3 limit switches is

More information

CQM1-SF200/CS1W-SF200

CQM1-SF200/CS1W-SF200 Safety Relay Unit ( I/O Unit Type) CQM1-SF200/CS1W-SF200 CSM_CQM1-SF200_CS1W-SF200_DS_E_2_1 A Safety Relay Unit That Functions as a I/O Unit. Less Installation Space and Wiring Required. Safety Relay Unit

More information

How To Use A Flowmeter

How To Use A Flowmeter INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

MasterINTERFACE 39 Series - Relay interface modules

MasterINTERFACE 39 Series - Relay interface modules MasterINTERFACE 39 Series - 39 Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy ejection by plastic

More information

Machine Safety Switch: SI-LM40 Series Limit Switch Style

Machine Safety Switch: SI-LM40 Series Limit Switch Style Machine Switch: SI-LM40 Series Limit Switch Style SI-LM40 Series Limit Switch Style with Flexible In-Line Actuator Positive-opening safety contacts (IEC 60947-5-1) (not dependent upon springs) Standard

More information

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2 Cylindrical Sensor E2E/E2E2 A New Series of Easy-to-use and Tough E2E/E2E2 Models Long-size E2E2 Sensor Conforms to CENELEC Ideal for a variety of applications. With a metal connector that can be tightened

More information

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Extract from the online catalog STEP-PS/1AC/12DC/1.5 Order No.: 2868567 DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Commercial data EAN 4046356292924 Pack 1 pcs. Customs tariff

More information

Motor circuit-breakers

Motor circuit-breakers Thermal-magnetic motor circuit-breakers type GV2-M GV2-M Thermal-magnetic motor circuit-breakers GV2-M Pushbutton control Standard power ratings Setting Magnetic Thermal Reference Weight of 3-phase motors

More information

14 PHOENIX CONTACT Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108. info@powermation.com - 800-843-9859 - www.powermation.

14 PHOENIX CONTACT Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108. info@powermation.com - 800-843-9859 - www.powermation. 14 PHOENIX CONTACT PLUSCON circular is a circular connector for use in industrial automation. The range of design sizes available is varied, starting with the design sizes M5 to M8 and M1, for sensor/actuator

More information

Type Sealing Poles Contacts Rated voltage Model Standard d Flux-tight 4 poles oes 3PST-NO, SPST-NC 24 VDC G7SA-3A1B 3PST-NO, 3PST-NC

Type Sealing Poles Contacts Rated voltage Model Standard d Flux-tight 4 poles oes 3PST-NO, SPST-NC 24 VDC G7SA-3A1B 3PST-NO, 3PST-NC Safety Relay Slim Safety Relays Conforming to EN Standards The forcibly guided contact in the assures safe operation (EN50205 Class A, approved by VDE.) Ideal for use in safety circuits in press machinery,

More information

HS5E. Safety Door Lock Switches. Four-contact safety switch with solenoid interlock. Ideal for use on small doors within limited space.

HS5E. Safety Door Lock Switches. Four-contact safety switch with solenoid interlock. Ideal for use on small doors within limited space. HS5E Safety Door Lock Switches Four-contact safety switch with solenoid interlock. Ideal for use on small doors within limited space. Solenoid type safety switch with four contacts. Compact Body. Ideal

More information

12S, 14S, 15S Series. Time Delay Relays and Sequencers. Time Delay Relays and Sequencers. Features and Benefits. Switch Actions and Configurations

12S, 14S, 15S Series. Time Delay Relays and Sequencers. Time Delay Relays and Sequencers. Features and Benefits. Switch Actions and Configurations 12S, 14S, 15S Series Time Delay Relays and Sequencers Time Delay Relays and Sequencers The Therm-O-Disc type 12S, 14S and 15S series time delay relays and sequencers are field-proven devices for controlling

More information

ONE OF THE SMALLEST SNAP-ACTION SWITCHES IN THE WORLD. FEATURES Superminiature type, light-weight snap action switch PC board terminal type (0.

ONE OF THE SMALLEST SNAP-ACTION SWITCHES IN THE WORLD. FEATURES Superminiature type, light-weight snap action switch PC board terminal type (0. ONE OF THE SMALLEST SNAP-ACTION SWITCHES IN THE WORLD SWITCHES FEATURES Superminiature type, light-weight snap action switch PC board terminal type (0.2g) Solder terminal type with mounting holes (0.3g)

More information

Electric Rotary Actuator - On/Off or programmable control actuator

Electric Rotary Actuator - On/Off or programmable control actuator Electric Rotary Actuator - On/Off or programmable control actuator Direct mounting on quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Multi-voltage version Type

More information

Machine Safety Switches

Machine Safety Switches Machine Switches SI-LS31H Series 31 mm Limit-Switch-Style with Hinged Lever Actuators Features Limit switch design (EN 50047) For use on doors or flaps Positive opening safety contacts (IEC 60947-5-1)

More information

Catalog. Modular DIN rail components Installation contactors

Catalog. Modular DIN rail components Installation contactors Catalog Modular DIN rail components Installation contactors 0 CDC00C00 Installation contactors Benefits and features Overview Ordering details ESB installation contactors ESB0 ESB ESB0 ESB 7 EN installation

More information

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display

More information

Technical data. General specifications. Signal voltage 15... 30 V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Technical data. General specifications. Signal voltage 15... 30 V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output. Model Number Features Very small housing High climatic resistance 4 Bit multiturn Analog output Surge and reverse polarity protection Description This absolute rotary encoder with internal magnetic sampling

More information

Plug and Socket Devices SolConeX 16 A Series 8570

Plug and Socket Devices SolConeX 16 A Series 8570 www.stahl.de > Switch socket / plug 16 A > Minimal force required to insert and remove > Can be optionally equipped with an auxiliary contact for control and signalling purposes > arge switching handle

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Gertebild ][Bildunterschrift Safety relay for monitoring E-STOP pushbuttons and safety gates. Unit features Gertemerkmale Positive-guided relay outputs: 2 safety contacts (N/O), instantaneous Connection

More information

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics 3/2-, 5/2-5/3-way Solenoid Valves for process pneumatics Type 6518 stard High flow-rate capacity Reduced power consumption Single or manifold mounting stard Type 6518/6519 can be combined with... Stard-,

More information

Inductive sensor NI10-M18-Y1X-H1141

Inductive sensor NI10-M18-Y1X-H1141 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M18 x 1 Chrome-plated brass DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR) M12

More information

Heavy Duty Solenoid Controlled Access Lock. User Manual - Original Language Version

Heavy Duty Solenoid Controlled Access Lock. User Manual - Original Language Version OLYM-S24D-C24D The Olympus 4HD is a heavy duty solenoid controlled access lock available with either a stainless steel tongue actuator or a heavy duty handle. The Olympus 4HD is capable of supporting Category

More information

General 1-2-Opto-electronics Safety Switches 4-Emergency

General 1-2-Opto-electronics Safety Switches 4-Emergency General 1-2-Opto-electronics Safety Switches 4-Emergency Logic Power The Lifeline 4 cable/push button operated system can be installed along or around awkward machinery such as conveyors and provide a

More information

Type: DILM32 10(24V50HZ) Article No.: 277247

Type: DILM32 10(24V50HZ) Article No.: 277247 Type: DILM32 10(24V50HZ) Article No.: 277247 Ordering information Rated operational current AC 3 400 V I e A 32 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors,

More information

Contact expansion modules

Contact expansion modules Gertebild ][Bildunterschrift Kontakterweiterungen Contact for increasing the number of available contacts Approvals Zulassungen Unit features Gertemerkmale Positive-guided relay outputs: 4 safety contacts

More information

4 Posiflow Proportional Solenoid Valves

4 Posiflow Proportional Solenoid Valves 4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/4" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Flow rate can also be regulated by a range of electrical inputs (sensors,

More information

8146/5 Series Breaker Panelboards

8146/5 Series Breaker Panelboards 8146/5 Series Breaker Panelboards DISTRIBUTION BREAKER PANELBOARDS FOR HAZARDOUS & CORROSIVE ENVIRONMENTS Breaker Panels Features: Wide variety of Flameproof branch circuit breakers for Zone 1 & Division

More information

Command devices Pull-wire emergency stop switches One-side operation ZS 71 range 6.1 6.1.1 6.1.1.1. 312 Schmersal -10 0 10 20 30 40 50 60 70 T [] C

Command devices Pull-wire emergency stop switches One-side operation ZS 71 range 6.1 6.1.1 6.1.1.1. 312 Schmersal -10 0 10 20 30 40 50 60 70 T [] C .1.1.1 One-side operation ZS 71 range 40 30 ø10 10 53,5(63)* 6 8 18 24 105 33 56 12 22 M20x1,5 52 17,5 42 15 Features To EN 418 / IEC 60947-5-5 Metal enclosure 2 contacts Small body 2 cable entries M20

More information

Pluggable interface relays CR-P Pcb relays

Pluggable interface relays CR-P Pcb relays 2CDC 293 034 F0004 1 2 4 3 Features 9 different supply s: DC versions: 12 V, 24 V, 48 V, 110 V AC versions: 24 V, 48 V, 110 V, 120 V, 230 V Output contacts: 1 c/o (16 A) or 2 c/o (8 A) Cadmium-free contact

More information

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO from 0... 00 mbar up to 0... 40 bar Output signals

More information

SIRCOVER. Manual changeover switches from 125 to 3200 A. Changeover switches. Function. Advantages. The solution for.

SIRCOVER. Manual changeover switches from 125 to 3200 A. Changeover switches. Function. Advantages. The solution for. The solution for Changeover switches svr_099_b_1_cat > Manufacturing industry. > Power distribution. 3200 Strong points svr_059_a_1_cat > complete range. > Easy connections. > Stable positions. > mproved

More information

NDQ5 Series. Automatic Transfer Switch. Shanghai Liangxin Electrical CO.,LTD

NDQ5 Series. Automatic Transfer Switch. Shanghai Liangxin Electrical CO.,LTD Shanghai Liangxin Electrical CO.,LTD Address: No. 668 Heng An Road, Pu Dong New District, Shanghai Zip: 200137 Tel: 86-21-5012789 Fax: 86-21-58675966 E-mail: client@sh-liangxin.com LINE 1 LINE 3 LINE 5

More information

mecotron Safety relay ESTOP-2 For emergency stop monitoring

mecotron Safety relay ESTOP-2 For emergency stop monitoring E0006 000824 Safety relay E-2 For emergency stop monitoring Description The safety module E-2 for emergency stop monitoring is used for safety breaking one or more circuits and is designed to be incorporated

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Unit features Safety features gang engertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided

More information

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs E031026 000823 Process modules Digital input PMI for inputs for 120 V AC inputs PMI Input E4, E5, GND L- PMI 120 V AC Input E4, E5, Common C E6, E7, GND L- E6, E7, Common C LEDs for the inputs operation

More information

MasterINTERFACE 39 Series - Relay interface modules

MasterINTERFACE 39 Series - Relay interface modules MasterINTERFACE 39 Series - Relay interface modules Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy

More information

ASSEMBLED SOCKET-COMBINATIONS

ASSEMBLED SOCKET-COMBINATIONS ASSEMBLED SOCKETCOMBINATIONS Enclosure extra strong, schockresistant easily open, it provides a comfortable mount it can be connected across a cable gland it consists of a 35 mm mounting rail Window 6

More information

PNOZsigma - Base units

PNOZsigma - Base units PNOZsigma - Base units Register Login Sensors Control and Communication Electronic monitoring relays Safety Relays PNOZ X PNOZsigma PNOZelog PNOZmulti PNOZpower Configurable control systems Programmable

More information

60 Series - General purpose relays 6-10 A. Features 60.12 60.13

60 Series - General purpose relays 6-10 A. Features 60.12 60.13 Features 60.12 60.13 Plug-in mount 10 A General purpose relay 2 & 3 pole changeover contacts Cadmium Free contacts (preferred version) AC coils & DC coils UL Listing (certain relay/socket combinations)

More information

Linear Luminaire with LED Series EXLUX 6402/2

Linear Luminaire with LED Series EXLUX 6402/2 > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Unit features Safety features Gertebild ][Bildunterschrift Safety relay for monitoring E-STOP pushbuttons and safety gates. Approvals Gertemerkmale Positive-guided relay outputs: 3 safety contacts (N/O),

More information

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays

More information