Safety automation solutions

Size: px
Start display at page:

Download "Safety automation solutions"

Transcription

1 Operating principle, characteristics Preventa safety s types XPS AV,, For and switch monitoring Operating principle Safety s XPS AV, and are used for monitoring circuits conforming to standards EN/ISO 850 and EN and also meet the safety requirements for the electrical monitoring of switches in protection devices conforming to standard EN 088. They provide protection for both the machine operator and the machine by immediately ping the dangerous movement on receipt of a instruction from the operator, or on detection of a fault in the safety circuit itself. Characteristics Module type In addition to the category 0 instantaneous opening safety ( for XPS AV, for and for ), the s incorporate category time delay ( for XPS AV, for and for ) which allow for controlled deceleration of the motor components until a complete is achieved (for example, motor braking by variable speed drive). At the end of the preset delay, the supply is disconnected by opening the time delay output circuits. For XPS AV, the time delay of the output circuits is adjustable, in 5 preset values, between 0 and 00 seconds using selector buttons. For, the time delay of the output circuits is adjustable between 0.5 and seconds or.5 and 0 seconds, depending on the model, using a selector switch. For, the time delay of the output circuits is adjustable between 0 and 0 seconds using a -position selector switch. Module XPS AV also incorporates solid-state signalling for signalling to the process PLC. Module incorporates 4 solid-state signalling for signalling to the process PLC. To aid diagnostics, the s have LEDs which provide information on the monitoring circuit status. The button monitoring function is confi gurable depending on the wiring. XPS AV, XPS AVP Maximum achievable safety level PL e/category 4 conforming to EN/ISO 849- SILCL (instantaneous safety and time delay safety ) conforming to EN/IEC 606 Reliability data (instantaneous safety ) Reliability data (time delay safety ) ppppc, ppppp PL e/category 4 (instantaneous safety ) and PL d/category (time delay safety ) conforming to EN/ISO 849-, SILCL (instantaneous safety ) and SILCL (time delay safety ) conforming to EN/IEC 606 pppp, ppppp Mean Time To dangerous Failure Years (MTTF d) Diagnostic Coverage (DC) % > 99 > 99 > 99 Probability of dangerous Failure per Hour (PFH d) /h 7.95 x 0-9 x x 0-9 Mean Time To dangerous Failure Years (MTTF d) Diagnostic Coverage (DC) % > 99 > 60 and < Probability of dangerous Failure per Hour (PFH d) /h 7.95 x 0-9 x x 0-8 Conformity to standards EN/IEC 6004-, EN/IEC , EN/IEC , EN/ISO 850, EN 088/ISO 49, EN/IEC 6004-, EN/IEC , EN/IEC , EN/ISO 850, EN 088/ISO 49 PL e/category 4 (instantaneous safety ) and PL d/category (time delay safety ) conforming to EN/ISO 849-, SILCL (instantaneous safety ) and SILCL (time delay safety ) conforming to EN/IEC 606 EN/IEC 6004-, EN/IEC , EN/IEC , EN/ISO 850, EN 088/ISO 49 Product certifications UL, CSA, TÜV UL, CSA, BG UL, CSA, TÜV Supply Voltage V 4 c 4 c a and 4 c, 5 a, 0 a Voltage limits % % % (4 V) % (5 V) % (0 V) Frequency Hz 50/60 Consumption W < 5 < < 8 Module inputs fuse protection Internal, electronic Adjustable time delay s or, button monitoring Yes/No (confi gurable by terminal connections) Control unit voltage (at nominal supply voltage) Between input terminals S-S, S-S or S-S Between input terminals S-S, S-S or S-S 4 V version V V, 0 V version V 48 Between input terminals S-S, S-S or S-B References: page 878-EN/4 Connections: page 878-EN/5 Dimensions: page 870-EN/ Characteristics: page 878-EN/ version: EN.indd

2 Characteristics (continued) Preventa safety s types XPS AV,, For and switch monitoring Characteristics (continued) Module type XPS... AV AVP ABVppppP ABVppppC ATEpppp ATEppppP Calculation of wiring resistance RL between input terminals Ω 00 max. Maximum cable length: 000 m Synchronisation time between inputs s For guard:.5 For : unlimited Outputs Voltage reference Volt-free Number and type of instantaneous opening safety circuits Number and type of time delay opening safety circuits RL = Ue Un x 60-7 Ue = true voltage applied to terminals A-A Un = nominal supply voltage RL max. = U int - U min. I min. Ue = true voltage applied to terminals A-A U int (terminals S-S) = supply voltage Ue - V (4 V version) U int between 4 V and 45 V, with typical value = 45 V (5 V, 0 V version) Calculated max. RL must be equal to or greater than the true value < 0.5 Approx For automatic start, terminals S-Y and Y-Y4 linked NO (0-04, -4, -4) NO (-4, -4) NO (-4, -4, -4) NO (7-8, 47-48, 57-58) NO (7-8) NO (57-58, 67-68, 77-78) Number and type of additional circuits solid-state 4 solid-state Breaking capacity in AC-5 Instantaneous VA C00: inrush 800, maintained 80 B00: inrush 600, maintained 60 C00: inrush 800, maintained 80 Time delay VA C00: inrush 800, maintained 80 B00: inrush 600, maintained 60 C00: inrush 800, maintained 80 Breaking capacity Instantaneous 4 V/.5 A L/R = 50 ms 4 V/.5 A L/R = 50 ms 4 V/.0 A L/R = 50 ms in DC- Time delay 4 V/.5 A L/R = 50 ms 4 V/.5 A L/R = 50 ms 4 V/.0 A L/R = 50 ms Breaking capacity of solid-state 4 V/0 ma Max. thermal current Instantaneous A. for all, or 6 for and 6 5 (Ithe) for, or 4 for and for Time delay A. for all, or 6 for and 6.5 for, or 4 for and for Max. total thermal current A 0 8 Output fuse protection, Instantaneous A 4 gg or 6 fast acting 6 gg 6 gg using fuses conforming to IEC/EN , Time delay A 4 gg or 6 fast acting 6 gg 4 gg DIN VDE 0660 part 00 Minimum current ma 0 () 0 0 () Minimum voltage V 7 () 7 7 () Electrical durability See page 860-EN/ Response time on instantaneous opening inputs ms < 0 < 00 < 0 Rated insulation voltage (Ui) V 00 (degree of pollution conforming to IEC/EN , DIN VDE 00 parts & ) Rated impulse withstand voltage (Uimp) kv 4 (overvoltage category III, conforming to IEC/EN , DIN VDE 00 parts & ) LED display 4 Operating temperature C Storage temperature C Degree of protection Terminals IP 0 conforming to IEC/EN 6059 Enclosure IP 40 Connections Type of terminals Captive screw Spring terminals Captive screw clamp terminals Type of terminal block Integrated in Removable from -wire connection Without cable end Solid or mm Solid or 0..5 mm With cable end Without bezel, mm With bezel, mm -wire connection Without cable end Solid or mm With bezel, mm With bezel, mm Solid or Solid or flexible cable: mm mm With bezel, With bezel, mm mm Solid or mm With bezel, flexible cable: mm Solid cable: 0. mm Solid or Solid cable: 0. mm Flexible cable: 0. mm 0..5 mm Flexible cable: 0..5 mm With cable end Without bezel, 0.5 mm Without bezel, flexible cable: 0.5 mm Double, with bezel, fl exible Double, with bezel, flexible Double, with bezel, flexible cable: mm cable: mm cable: 0.5 mm () The is also capable of switching low power loads (7 V/0 ma) provided that the contact has not been used for switching high power loads (possible contamination or wear of the gold layer on the contact tips). 878-EN.indd version: 7.

3 References Preventa safety s types XPS AV,, For and switch monitoring References Description Safety s for and switch monitoring Number of safety circuits 6 NO ( NO time delay) Additional Setting range of time delay Supply Connection Reference Weight solid-state 0 00 s 4 V c Captive screw integrated in kg XPS AV NO ( NO time delay) solid-state 0 00 s 4 V c Captive screw XPS AVP 0.0 XPS AV NO ( NO time delay) 0.5 s 4 V c Captive screw P V c Spring terminals C 0.75 XPS AVP.5 0 s 4 V c Captive screw XPS ABV0P V c Spring terminals XPS ABV0C NO ( NO time delay) 4 solid-state 0 0 s a/4 V c Captive screw integrated in ppppp Captive screw 5 V a Captive screw integrated in 50P ppppc Captive screw 40P V a Captive screw integrated in Captive screw 70P version: EN.indd

4 Connections Preventa safety s type XPS AV For and switch monitoring XPS AV Module XPS AV associated with an button with NC contact, automatic start or unmonitored start To PLC channel Output Output channel Output Output Fault Time delay () Link for automatic start. () Instantaneous opening safety ( category 0). () Time delay opening safety ( category ). ESC = External start conditions. Functional diagrams Automatic start Power-up not S-S Automatic start (without ESC) S-S4 S-S S-S Time delay interrupt Y9-Y /-4/-4 7-8/47-48/57-58 Y74 Y84 Automatic start There is no start contact or it is shunted. Unmonitored start The output is on closing of the start contact. not Tv = 0 00 s Time delay interrupted Unmonitored start Power-up not S-S button S-S4 S-S S-S Time delay interrupt Y9-Y /-4/-4 7-8/47-48/57-58 Y74 Y84 not Tv = 0 00 s Time delay interrupted Monitored start The start input is monitored so that there is no start-up in the event of the start contact being shunted or the start circuit being closed for more than 0 seconds. -up is triggered following activation of the start button (push-release function) on opening of the contact. 878-EN.indd version: 7. 5

5 Connections (continued) Preventa safety s type XPS AV For and switch monitoring XPS AV Module XPS AV associated with an button with NC contacts, monitored start To PLC channel Output Output channel Output Output Fault Time delay () Instantaneous opening safety ( category 0). () Time delay opening safety ( category ). ESC = External start conditions. Functional diagram Monitored start Power-up not not S-S (channel ) S-S (channel ) S-S button S-S4 Time delay interrupt Y9-Y /-4/-4 7-8/47-48/57-58 Y74 Y84 No start-up Tv = 0 00 s Time delay interrupted monitoring function configuration -channel wiring S -channel wiring, with short-circuit detection S A S S S S XPS AV A S S S S XPS AV A S S A S S 6 version: EN.indd

6 Connections (continued) Preventa safety s type XPS AV For and switch monitoring XPS AV Monitoring of a movable guard associated with switches Automatic start (diagram shown for guard closed) closed To PLC channel Output Output channel Output Output Fault closed Time delay () Instantaneous opening safety ( category 0). () Time delay opening safety ( category ). ESC = External start conditions. Functional diagram S-S (channel ) S-S (channel ) S-S open S-S4 Time delay interrupt Y9-Y /-4/-4 7-8/47-48/57-58 Y74 Y84 LED details Power-up closed open closed open Tv = 0 00 s closed open Time delay interrupted S input status. S input status. S input status. 4 S4 input status. 5 S4 input status. 6 Y40 input status (time delay ). 7 K/K status (NO instantaneous opening safety ). 8 K/K4 status (time delay opening safety ). 9 Supply voltage A-A. 0 Fault. Confi guration mode. 878-EN.indd version: 7. 7

7 Connections (continued) Preventa safety s type For and switch monitoring Module XPS AV associated with an button with NC contacts, monitored start + 4 V F0 Feedback loop () () S F () F () F () A S S4 S5 7 Reset K Control logic K Supply Time (s) channel channel channel K K4 0 V A S S S S S Stop category 0 Stop category 0 Safety Stop category S: S: button ESC = External start conditions. () With start button monitoring. () Without start button monitoring or automatic start. () Maximum fuse rating: see technical characteristics. or switch monitoring function configurations S S S S S4 S S ON -channel, manual start with S4 button monitoring Link ON S S S S S4 S S Short-circuit monitoring -channel, manual start with S4 button monitoring Link ON S S S S S S4 S S Short-circuit monitoring -channel, manual start with S4 button monitoring Link 4 S S S S S S5 S S Machine guard with short-circuit monitoring, automatic start Link or feedback loop for external contactors (automatic start S5) Link 8 version: EN.indd

8 Connections (continued) Preventa safety s type For and switch monitoring Functional diagrams monitoring: configurations, and Power-up Begin not Supply voltage (A-A). Channel (S-S) Begin. Channel S-S (S-S) Falling edge start S-S4 Rising edge start S-S5 Output -4, -4 (NO) Output 7-8 (NO) 0 tw >tm te ta tv >tm te >ta tw: Recovery time te: On-delay tm: Min. ON time ta: Response time tv: Off-delay (adjustable) ts: Synchronisation time Switch monitoring: configuration 4 Supply voltage (A-A) Power-up closed open closed. Channel (S-S). Channel S-S (S-S) Rising edge start S-S5 Output -4, -4 (NO) Output 7-8 (NO) 0 te ta tv tw ts te ta tw: Recovery time te: On-delay tm: Min. ON time ta: Response time tv: Off-delay (adjustable) ts: Synchronisation time LED details Supply voltage A-A K/K status K/K4 status 878-EN.indd version: 7. 9

9 Connections Preventa safety s type For and switch monitoring Module associated with an button Stop category 0 Instantaneous opening safety Stop category Time delay opening safety To PLC S: button with NC contacts (recommended application). S: button. ESC: External start conditions. Y (S) - Y: Feedback loop. F: 4 A max. () With start button monitoring. () Without start button monitoring. () The must be fuse protected. Technical characteristics for establishing maximum rating of fuses, see page 878-EN/. (4) 5/0 V a only. Functional diagram of with button monitoring Supply Begin voltage not With button Without button (O) Solid-state output Y89 (S) (O) Solid-state output Y90 (S) button button (O or O) Solid-state output Y89 (S) (O or O) Solid-state output Y90 (S) button Tmax. = 75 ms Outputs Solid-state output Y88 (A/A) Solid-state output Y9 (Stop ) Tv = 0 0 s Key 0 With start button monitoring (Y-Y5 connection). Without start button monitoring (Y-Y4 connection). Without start button (connection Y-Y4 and S-Y). Tv: adjustable time. LED details 4 External start conditions Output -4 (NO) Output -4 (NO) Output (NO) Output (NO) Output (NO) 4 Supply voltage A-A, internal electronic fuse status. S (A) input status. S (B) input status. Stop category closed. 0 version: EN.indd

10 Connections (continued) Preventa safety s type For and switch monitoring Example of a safety circuit combining an with a variable speed drive PLC To PLC S: button with NC contacts (recommended application). S: button () With start button monitoring. () Technical characteristics for establishing maximum rating of fuses, see page 878-EN/. Connection with button Connection with multiple buttons S S A S S B S S Both input channels are supplied at the same potential. S: button with NC contacts A short-circuit between the inputs is not detected. S S A S S B S S The input channels are supplied at different potentials. A short-circuit between the inputs is detected. Configuration with start button monitoring (functional diagram for button, see page 878-EN/5 ) Monitoring an button with NC contact A PE S Y Y Y Y4 Y5 S () () Auxiliary terminal (to be used to separate the feedback loop from the wiring to the start button). Configuration without start button monitoring (functional diagram for button, see page 878-EN/5 ) S A S S B S S S: button with NC contact. Not all faults are detected: a short-circuit on the pushbutton is not detected. A PE S Y Y Y Y4 Y5 S () () Auxiliary terminal (to be used to separate the feedback loop from the wiring to the start button). 878-EN.indd version: 7.

Preventa Machine Safety Products

Preventa Machine Safety Products Preventa Machine Safety Products Catalog 2009 200 Supplement Safety Relay Modules 2 Contents Preventa safety relay modules Selection guide 2 Electrical Ratings 6 Types XPSAC and XPSAXE For Emergency stop

More information

mecotron Safety relay ESTOP-2 For emergency stop monitoring

mecotron Safety relay ESTOP-2 For emergency stop monitoring E0006 000824 Safety relay E-2 For emergency stop monitoring Description The safety module E-2 for emergency stop monitoring is used for safety breaking one or more circuits and is designed to be incorporated

More information

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications. Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description

More information

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil Product data sheet Characteristics LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

Safety technique. Emergency stop module BO 5988 safemaster

Safety technique. Emergency stop module BO 5988 safemaster Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided

More information

CONFIGURABLE SAFETY RELAYS

CONFIGURABLE SAFETY RELAYS MSI-s/R, MSI-sx/Rx Configurable MSI provide important functions for the efficient flow of automated production processes Special features Combined guarding types by connecting up to 4 AOPDs Additional

More information

Safety Relays ESM/ESM-F

Safety Relays ESM/ESM-F Safety Relays ESM/ESM-F More than safety. Safety More than safety. Emil Euchner, the company s founder and inventor of the multiple limit switch, circa 1928. Around the world the Swabian specialists in

More information

Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order

More information

CONFIGURABLE SAFETY RELAYS

CONFIGURABLE SAFETY RELAYS MSI-m/R, MSI-mx/Rx Configurable MSI Safety Relay with function for efficient material flow in a packaging application Special features Sequential or Parallel with automatic mode detection MSI-mx for separate

More information

RM4TG20 three-phase network control relay RM4-T - range 200..500 V

RM4TG20 three-phase network control relay RM4-T - range 200..500 V Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking

More information

Safety detection solutions

Safety detection solutions Presentation, actuator operated etal, types CS A, CS B, CS C and CS E Plastic, double insulated, turret head, types CS P or CS PA or CS TA and CS TE etal, types CS A, CS B, CS C, CS E with or without locking

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Gertebild ][Bildunterschrift Safety relay for monitoring E-STOP pushbuttons and safety gates. Approvals Unit features Gertemerkmale Positive-guided relay outputs: 2 safety contacts (N/O), instantaneous

More information

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of

More information

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only

More information

HERZ-Thermal Actuators

HERZ-Thermal Actuators HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01

More information

PNOZsigma - Base units

PNOZsigma - Base units PNOZsigma - Base units Register Login Sensors Control and Communication Electronic monitoring relays Safety Relays PNOZ X PNOZsigma PNOZelog PNOZmulti PNOZpower Configurable control systems Programmable

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Unit features Safety features Gertebild ][Bildunterschrift Safety relay for monitoring E-STOP pushbuttons and safety gates. Approvals Gertemerkmale Positive-guided relay outputs: 3 safety contacts (N/O),

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Gertebild ][Bildunterschrift Safety relay for monitoring E-STOP pushbuttons and safety gates. Unit features Gertemerkmale Positive-guided relay outputs: 2 safety contacts (N/O), instantaneous Connection

More information

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage

More information

Safety Manual BT50(T) Safety relay / Expansion relay

Safety Manual BT50(T) Safety relay / Expansion relay Safety Manual BT50(T) Safety relay / Expansion relay ABB Jokab Safety Varlabergsvägen 11, SE-434 39, Sweden www.abb.com/jokabsafety Read and understand this document Please read and understand this document

More information

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101433D0201 28/03/11 NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits.

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Unit features Safety features gang engertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided

More information

AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101403D0201 24/03/11 AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF09(Z) contactors are used for controlling power circuits

More information

R.C.C.B. s two-pole LEXIC

R.C.C.B. s two-pole LEXIC 87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s two-pole LEXIC 089 06/09/10/11/12/15/16/17/18/ 27/28/29/30/35, CONTENTS PAGES 1. Electrical and mechanical characteristics...

More information

Contact expander modules

Contact expander modules Gertebild ][Bildunterschrift Kontakterweiterungen Contact expansion module for increasing the number of available contacts Approvals Zulassungen Unit features Gertemerkmale Positive-guided relay outputs:

More information

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear Mini Motor Contactor J7KNA ) Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN-rail) Range from 4 to 5.5 (AC 3, 380/415V) 4 -main pole version (4 AC

More information

Electronic overload relay EF19 and EF45

Electronic overload relay EF19 and EF45 Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor

More information

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical

More information

Manual Motor Starter MS 116 up to 16 A Technical Data

Manual Motor Starter MS 116 up to 16 A Technical Data Manual Motor Starter MS 116 up to 16 A Technical Data Type MS 116 Standards: Major International IEC 60 947-4-1 / IEC 60 947-2 and European Standards EN 60 947-4-1 / EN 60 947-2 Approvals, Certificates

More information

Switch Actuator, 8-fold, 10 A, MDRC AT/S 8.10.1, GH Q631 0075 R0111

Switch Actuator, 8-fold, 10 A, MDRC AT/S 8.10.1, GH Q631 0075 R0111 , GH Q631 0075 R0111 The 8-fold switch actuator is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via a bus terminal. In the event of bus voltage failure,

More information

Contact expansion modules

Contact expansion modules Gertebild ][Bildunterschrift Kontakterweiterungen Contact for increasing the number of available contacts Approvals Zulassungen Unit features Gertemerkmale Positive-guided relay outputs: 4 safety contacts

More information

Pendant control stations 6

Pendant control stations 6 Characteristics 6 Environment Conformity to standards EN/IEC 6097-5-1 EN/IEC 600-, UL 508, CSA C- n EN/IEC 6097-5-5 and EN/ISO 850 for versions with trigger action Emergency stop Product certifications

More information

SMS 4 / SMS 5 safety mat Product information

SMS 4 / SMS 5 safety mat Product information SMS 4 / SMS 5 safety mat Product information SMS 4 / SMS 5 safety mats Safety mats are used for the protection of man on machinery and plants with hazardous movements. Typical fields of application are,

More information

Three-phase monitoring relay CM-PFE

Three-phase monitoring relay CM-PFE Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics

More information

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays

More information

Electronic overload relay EF65, EF96 and EF146

Electronic overload relay EF65, EF96 and EF146 Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays.

More information

RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters

RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters Characteristics multifunction voltage control relay RM35-U - range 15..600 V Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main

More information

MasterINTERFACE 39 Series - Relay interface modules

MasterINTERFACE 39 Series - Relay interface modules MasterINTERFACE 39 Series - Relay interface modules Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy

More information

MasterINTERFACE 39 Series - Relay interface modules

MasterINTERFACE 39 Series - Relay interface modules MasterINTERFACE 39 Series - 39 Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy ejection by plastic

More information

Series 8146/5-V37 and Series 8150/5-V37

Series 8146/5-V37 and Series 8150/5-V37 www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection

More information

Micro Contactors. Micro Contactor Relays. Micro Contactors With Solder Pins. Coil voltages. Micro Reversing Contactor. Technical Data.

Micro Contactors. Micro Contactor Relays. Micro Contactors With Solder Pins. Coil voltages. Micro Reversing Contactor. Technical Data. Micro Contactors Micro Contactor Relays 0 Micro Contactors Micro Contactors With Solder Pins Coil voltages Micro Reversing Contactor 3 Technical Data 4 Dimensions 8 9 Micro Contactor Relays 4pole C Operated

More information

Catalog. Modular DIN rail components Installation contactors

Catalog. Modular DIN rail components Installation contactors Catalog Modular DIN rail components Installation contactors 0 CDC00C00 Installation contactors Benefits and features Overview Ordering details ESB installation contactors ESB0 ESB ESB0 ESB 7 EN installation

More information

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems LIETRAXX -A etwork and system protection (S protection) for monitoring the power feed-in of power generation systems TDB301021en/06.2013 LIETRAXX -A etwork and system protection (S protection) for monitoring

More information

Relés e Contatores de Estado Sólido SIRIUS

Relés e Contatores de Estado Sólido SIRIUS Relés e Contatores de Estado Sólido SIRIUS Coletânea de dados técnicos ( product data sheet ) Agosto/212 SSR - 3RF21 22,5 mm Ponto Zero SSR - 3RF2 45 mm Ponto Zero SSR - 3RF22 45 mm Ponto Zero Trifásico

More information

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages The CM-ESS.M is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

Manual motor starter MS116

Manual motor starter MS116 Data sheet Manual motor starter MS116 Manual motor starters are electromechanical devices for motor and circuit protection. These devices offer local motor disconnect means, manual ON/ OFF control, and

More information

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency echnical data sheet NV24A--RE Communicative globe valve actuator for 2-way and 3-way globe valves Actuating force 1000 N Nominal voltage AC/DC 24 V Control Modulating DC (0)2...10 V Variable Nominal stroke

More information

Thermal-Magnetic Circuit Breaker 3120-...-M1-..

Thermal-Magnetic Circuit Breaker 3120-...-M1-.. Thermal-Magnetic Circuit Breaker -...-M-.. Description Single or two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 34). The addition of a magnetic tripping

More information

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories 2CDC 251 014 F0t09 Features Monitoring of three-phase mains for grid feeding Type-tested in accordance with DIN V VDE V 0126-1-1: February 2006 Neutral conductor connection configurable Can also be used

More information

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application. 1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Unit features Unit description Gertebild ][Bildunterschrift Safety relay for monitoring E-STOP pushbuttons and safety gates. Approvals Gertemerkmale Positive-guided relay outputs: 3 safety contacts (N/O),

More information

PROTECT. Safety Relay Modules PROTECT-SRB s Catalogue Protect/04

PROTECT. Safety Relay Modules PROTECT-SRB s Catalogue Protect/04 PROTECT Safety Relay Modules PROTECT-SRB s Catalogue Protect/04 Subject to technical modifications and error. The data specified in this catalogue are carefully checked typical standard values. Or as the

More information

225-230T-05-S2. Rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

225-230T-05-S2. Rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators Actuators Technical data sheet 225-230T-05-S2 Rotary drive without spring return Description Actuator for adjusting air dampers of 90 angle of rotation to be used in HVAC installations. Torque Motor 5

More information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC

More information

VEO. V4PF480Y/277VSYTK02 Art.Nr.: 2104200. V4PF480Y/277VSYTK02P Art.Nr.: 2104210 TECHNICAL DATA

VEO. V4PF480Y/277VSYTK02 Art.Nr.: 2104200. V4PF480Y/277VSYTK02P Art.Nr.: 2104210 TECHNICAL DATA Monitoring of phase sequence and phase loss Monitoring of asymmetry Temperature monitoring (PTC) Supply voltage 208-480 V AC Supply circuit = measuring circuit 2 change-over contacts Width 45 mm Control

More information

48 SERIES Relay interface modules 10 A

48 SERIES Relay interface modules 10 A 48 Relay interface modules 10 A 1 CO relay interface modules, mm wide Ideal interface for PLC and electronic systems Type 48.P3 1 CO 10 A s Type 48.31 1 CO 10 A s AC coils or DC sensitive coils Supply

More information

Technicaldata General

Technicaldata General Currenttransformer-operatedoverloadrelay,60-90A,1N/O+1N/C Partno. ZW7-90 Articleno. 002618 CatalogNo. XTOT090C3S Deliveryprogramme Product range ZW7 current transformer-operated overload relays Description

More information

Type: DILM32 10(24V50HZ) Article No.: 277247

Type: DILM32 10(24V50HZ) Article No.: 277247 Type: DILM32 10(24V50HZ) Article No.: 277247 Ordering information Rated operational current AC 3 400 V I e A 32 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors,

More information

48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0.

48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0. 48 Series - Relay interface modules 8 A Features 48.12 2 Pole Safety relay interface modules, 15.8 mm wide 48.12-2 Pole 8 A (screw terminal) DC sensitive coils Relay with forcibly guided contacts according

More information

HSP GmbH Zum Handwerkerhof 2 90530 Wendelstein Tel. 09129 / 2852-0 Fax: 09129 / 2852-11 Web: www.hsshsp.de EMAIL: HSP@hsshsp.de NTG-3000.

HSP GmbH Zum Handwerkerhof 2 90530 Wendelstein Tel. 09129 / 2852-0 Fax: 09129 / 2852-11 Web: www.hsshsp.de EMAIL: HSP@hsshsp.de NTG-3000. NTG-3000 Transducer Data Sheet Document Version 2.8 Page 1 of 10 Versions / Revisions: Document Creation Author Description version date 2.0 2012-07-25 P. Compensis First official version 2.1 2012-08-24

More information

Safety Relay Units. G9SR family. Diagnosis with LEDs Selectable operating modes and times Increased extension possibilities. industrial.omron.

Safety Relay Units. G9SR family. Diagnosis with LEDs Selectable operating modes and times Increased extension possibilities. industrial.omron. Safety Relay Units G9SR family Diagnosis with LEDs Selectable operating modes and times Increased extension possibilities industrial.omron.eu/g9sr ... A complete standalone Safety Relay Unit family - G9SR

More information

DALI RC BASIC SO. Control unit Operating instructions

DALI RC BASIC SO. Control unit Operating instructions DALI RC BASIC SO Control unit Operating instructions Contents Safety... 4 General instructions 4 Safety instructions 4 Description... 5 Purpose and application 5 Function 5 Light control 5 Brightness

More information

Thermistor motor protection

Thermistor motor protection Thermistor motor protection CM-E Range Thermistor motor protection Thermistor motor protection relays Benefits and advantages Selection table Operating principle and fields of application for thermistor

More information

CQM1-SF200/CS1W-SF200

CQM1-SF200/CS1W-SF200 Safety Relay Unit ( I/O Unit Type) CQM1-SF200/CS1W-SF200 CSM_CQM1-SF200_CS1W-SF200_DS_E_2_1 A Safety Relay Unit That Functions as a I/O Unit. Less Installation Space and Wiring Required. Safety Relay Unit

More information

49 Series - Relay interface modules 8-10 - 16 A. Features

49 Series - Relay interface modules 8-10 - 16 A. Features Features 1 & 2 Pole relay interface modules 5 µm Gold plate contacts for low level switching capability 49.31-50x0-1 Pole 10 A (screw terminal) 49.52-50x0-2 Pole 8 A (screw terminal) 49.72-50x0-2 Pole

More information

Technical catalogue. Modular DIN rail components Installation contactors

Technical catalogue. Modular DIN rail components Installation contactors Technical catalogue Modular DIN rail components Installation contactors Installation Contactors Overview... ESB Installation Contactors 0 A / AC-/AC-7a ESB0...4 4 A / AC-/AC-7a ESB4...5 40 A / AC-/AC-7a

More information

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Product datasheet Characteristics TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus

More information

Installation Contactors. Technical Catalogue. Type ESB. abb. ABB STOTZ-KONTAKT GmbH 1 2CDC 103002 C0201

Installation Contactors. Technical Catalogue. Type ESB. abb. ABB STOTZ-KONTAKT GmbH 1 2CDC 103002 C0201 Technical Catalogue Installation Contactors Type ESB abb ABB STOTZ-KONTAKT GmbH 1 CDC 10300 C001 ABB STOTZ-KONTAKT GmbH CDC 10300 C001 Low Voltage Products and Systems We ensure safety and comfort for

More information

Bimetallic Overload Relay Specifications

Bimetallic Overload Relay Specifications Technical Data Bimetallic Overload Relay Specifications Bulletin Number 193K, 193T1 Topic Page Product Overview 2 Standards compliance and Certifications 2 General Specifications 193K 3 Approximate Dimensions

More information

Single-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Single-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable Features 70.11 70.31 70.41 Electronic voltage monitoring relays for single and three-phase applications Multifunctional types, providing the flexibility of monitoring Undervoltage, Overvoltage, Window

More information

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

PNOZ s3. Safety relays. Operating Manual-21395-EN-10

PNOZ s3. Safety relays. Operating Manual-21395-EN-10 Safety relays Operating Manual- Preface This document is the original document. All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may be made for internal purposes. Suggestions

More information

Fixed - Over/Under voltage limits, (0.75...1.2) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits

Fixed - Over/Under voltage limits, (0.75...1.2) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits Features 71.11.8.230.0010 71.11.8.230.1010 1 - Phase 230 V Over & Under voltage monitoring relays 71.11.8.230.0010 - Fixed Over & Under voltage detection - Link selectable 5 or 10 minute lock-out delay

More information

BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview

BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview BETA Switching Siemens AG 200 5TT5 Insta contactors, AC technology Overview The 5TT5 Insta contactors are equipped with an AC magnetic system and are ideal for use under harsh conditions. The auxiliary

More information

SKR - industry relay

SKR - industry relay SKR - industry relay the universal relay SKR the time module STM the socket The strengths of the SKR industry relay lie in the mature and thoughtout construction. Over-average contact safety and life time,

More information

ABB i-bus EIB / KNX EIB Monitoring Unit EUB/S 1.1

ABB i-bus EIB / KNX EIB Monitoring Unit EUB/S 1.1 Product Manual ABB i-bus EIB / KNX EIB Monitoring Unit EUB/S 1.1 Intelligent Installation Systems This manual describes the function of the EIB monitoring module EUB/S 1.1 with the Application program

More information

Type: DILM9 10(24VDC) Article No.: 276705

Type: DILM9 10(24VDC) Article No.: 276705 Type: DILM9 10(24VDC) Article No.: 276705 Ordering information Rated operational current AC 3 400 V I e A 9 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors, 50

More information

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S 4.230.1, GH Q631 0076 R0111. ABB i-bus EIB

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S 4.230.1, GH Q631 0076 R0111. ABB i-bus EIB , GH Q631 0076 R0111 2CDC 071 240 F0003 The Shutter Actuator Standard is used to control a maximum of four independent 230 VAC drives for positioning shutters, blinds, awnings and other hangings as well

More information

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.: 2964050

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.: 2964050 Extract from the online catalog DEK-REL- 24/1/SEN Order No.: 2964050 Relay terminal block for sensor, with soldered-in miniature relays, contact (AgNi+Au): small to medium loads, 1 N/O contact, input voltage

More information

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils

More information

ABB i-bus EIB Shutter Actuators JA/S 2.230.1, JA/S 4.230.1, JA/S 8.230.1, JA/S 4.230.1M, JA/S 8.230.1M, JA/S 4.24.1

ABB i-bus EIB Shutter Actuators JA/S 2.230.1, JA/S 4.230.1, JA/S 8.230.1, JA/S 4.230.1M, JA/S 8.230.1M, JA/S 4.24.1 Product Manual ABB i-bus EIB Shutter Actuators JA/S 2.230.1, JA/S 4.230.1, JA/S 8.230.1, JA/S 4.230.1M, JA/S 8.230.1M, JA/S 4.24.1 Intelligent Installation Systems Contents Page 1 Introduction.......................................

More information

XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm

XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm Characteristics XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm Complementary Detection system Kit composition [EAA] effective aperture angle Emission Main Range of product Product or

More information

Easy Multifunctional Safe

Easy Multifunctional Safe EMS Electronic motor starters www.eaton.eu Easy Multifunctional Safe EMS Multifaceted Performance with only 0 mm Eaton Moeller series products have always embodied quality and reliability in the machine

More information

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display

More information

General 1-2-Opto-electronics Safety Switches 4-Emergency

General 1-2-Opto-electronics Safety Switches 4-Emergency General 1-2-Opto-electronics Safety Switches 4-Emergency Logic Power The Lifeline 4 cable/push button operated system can be installed along or around awkward machinery such as conveyors and provide a

More information

Safe timer relay/contact expansion modules

Safe timer relay/contact expansion modules ??Gertebild Bildunterschrift Contact expander module for increasing the number of available contacts, Pulse-on timer relay for step-by-step control of movement sequences, Delay-on energisation timer for

More information

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001 Analogue Input, -fold, MDRC, GH Q605 005 R0001 The analogue input is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via the bus connecting terminal supplied.

More information

Brake module AX5021. Documentation. Please read this document carefully before installing and commissioning the brake module!

Brake module AX5021. Documentation. Please read this document carefully before installing and commissioning the brake module! Documentation Brake module AX5021 Please read this document carefully before installing and commissioning the brake module! Version : 1.2 : 2012.03.05 Date Article-no. : TDmlAX-5021-0000-0200 Page 2/8

More information

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage without power de-rating Efficiency > 87.0% @ 115Vac & 230Vac NEC Class 2 / Limited

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Unit features Unit description Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided

More information

Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830

Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830 Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830 Ordering information Rated operational current AC 3 400 V I e A 50 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase

More information

38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6. 38 Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit 6.2 mm wide EMR - DC, AC or AC/DC

More information

NDQ5 Series. Automatic Transfer Switch. Shanghai Liangxin Electrical CO.,LTD

NDQ5 Series. Automatic Transfer Switch. Shanghai Liangxin Electrical CO.,LTD Shanghai Liangxin Electrical CO.,LTD Address: No. 668 Heng An Road, Pu Dong New District, Shanghai Zip: 200137 Tel: 86-21-5012789 Fax: 86-21-58675966 E-mail: client@sh-liangxin.com LINE 1 LINE 3 LINE 5

More information

Safety dialogue solutions

Safety dialogue solutions General Presentation Emergency stop trip wire switches Emergency stop trip wire switches are designed to: b avert hazards (dangerous phenomena) at the earliest possible moment, or to reduce risks which

More information

Technical Manual Functional Description for S800-RSU-H / S800W-RSU 2CCC413022M0205. 8201 Schaffhausen 1 / 10

Technical Manual Functional Description for S800-RSU-H / S800W-RSU 2CCC413022M0205. 8201 Schaffhausen 1 / 10 ABB ABB Schweiz AG Technical Manual Functional Description for S800-RSU-H / S800W-RSU 2CCC413022M0205 09.04.2014 Page: 8201 Schaffhausen 1 / 10 Please use also the assembly instruction S800-RSU-H Remote

More information

Grid feeding monitoring according to VDE-AR-N 4105 and BDEW CM-UFD.M31

Grid feeding monitoring according to VDE-AR-N 4105 and BDEW CM-UFD.M31 Data sheet Grid feeding monitoring according to VDE-AR-N 4105 and BDEW CM-UFD.M31 The CM-UFD.M31 is a multifunctional grid feeding monitoring relay. It provides different monitoring functions in accordance

More information

Pluggable interface relays CR-P Pcb relays

Pluggable interface relays CR-P Pcb relays 2CDC 293 034 F0004 1 2 4 3 Features 9 different supply s: DC versions: 12 V, 24 V, 48 V, 110 V AC versions: 24 V, 48 V, 110 V, 120 V, 230 V Output contacts: 1 c/o (16 A) or 2 c/o (8 A) Cadmium-free contact

More information

Actuator-Sensor-Interface

Actuator-Sensor-Interface Selection and ordering data Design Order No. Price Pack 3RX9 307-0AA00 3RX9 307-1AA00 4FD5 213-0AA10-1A 3RX9 305-1AA00 3RX9 306-1AA00 Single output IP 65 current 2.4 A Rated input voltage DC 24 V current

More information

5SV Residual Current Protective Devices

5SV Residual Current Protective Devices s Siemens AG 2013 SENTRON 5SV Residual Current Protective Devices New portfolio for reliable personnel, material and fire protection Safe protection against residual currents Residual current protective

More information