D-Line Contactors, Overload Relays and Accessories
|
|
|
- Mariah Tate
- 9 years ago
- Views:
Transcription
1 D-Line Contactors, Overload Relays and Accessories Class 850 CONTENTS Description Page General Information Mini-Contactors Characteristics Selection Auxiliary Contacts, Timers and Accessories Replacement Coils Dimensions and Mounting Schematics Overload Relays Characteristics Selection Dimensions, Mounting, and Schematics Low Consumption DC Coil Mini-Contactors Characteristics Selection Auxiliary Contacts, Timers, and Accessories Dimensions and Mounting Schematics Capacitor Switching Contactors Plate-Mounted Starters Wye-Delta Starters Enclosed Contactors and Starters Horsepower Rated Devices for North American Applications Kilowatt Rated Devices for International Applications Definitions and Comments
2 D-Line Contactors, Overload Relays and Accessories General Information Introduction The Telemecanique family of IEC style contactors and starters are the largest selling motor control devices in the world. When the application calls for world class products, select the Telemecanique IEC style contactors and starters for products that are marketed and sold in over 60 countries. Most devices are UL listed, CSA certified, CE marked, meet IEC 97 standards and are approved by most other international approved agencies. The Telemecanique family of IEC style contactors and starters include the following: K-Line mini-contactors and overload relays are for general purpose starting and protection in a small package for loads up to Amps or resistive loads up to 0 Amps. D-Line contactors and overload relays offer the largest offering of accessories for maximum flexibility in customer applications and automated systems up to 50 motor full-load Amps or 00 Amp resistive loads. F-Line contactors and solid state overload relays are for inductive loads up to 800 Amps or resistive loads up to 350 Amps and share common accessories with the D-Line. GV manual starters provide manual isolation, manual motor control and overcurrent protection in one compact unit. They are approved for Group Motor Installations when used alone or with D-Line contactors. Integral self-protected starters combine all the functions of a disconnect switch, circuit breaker, contactor and overload relay in one coordinated unit to reduce required panel space by as much as 60% and reduce installation and wiring time. Selection of Telemecanique K-Line, D-Line and F-Line contactors are based on Utilization Categories, a combination of application and duty cycle rates defined by the following: The type of application (inductive motor loads or resistive loads) The conditions under which making or breaking current takes place (motor starting or running, reversing, plugging or jogging, locked rotor or stalled motor) Number of making and breaking operations (or cycles) required for the life of the contactor When specifying Telemecanique IEC contactors and starters refer to the following Square D documents: Catalog No. 850CT980 Catalog No. 850CT9703 Catalog No. 850CT970 Catalog No. 850CT970 Catalog No. 50CT950 Catalog No. 8539CT90 IEC Contactors Selection Guide K-Line Contactors, Overload Relays and Accessories D-Line Contactors, Overload Relays and Accessories F-Line Contactors, Overload Relays and Accessories GV/GV3 Manual Starters and AK5 Panel Busbar System Integral Self-Protected Starters 998 Square D All Rights Reserved 7/98
3 D-Line Contactors, Overload Relays and Accessories General Information The D-Line Contactors and Overload Relays are the largest selling line of contactors and starters in the world. They offer high reliability with long mechanical and electrical life and the most complete line of accessories in the industry. Contactor ratings D-Line contactors and overload relays are available in eleven contactor ratings for the USA market for inductive motor applications up to 50 full load Amps and resistive loads up to 00 Amps. They offer motor control and overload protection for motors rated up to 00 horsepower at 80 VAC or 5 horsepower at 600 VAC. 3-pole and -pole contactor versions available. Most contactors include built-in auxiliary contacts. All screw connections have IP0 rated Finger-safe terminals with both North American and International terminal markings. D-Line contactors can be panel mounted with screws or DIN rail mounted. Available in 3-pole contactor versions with built-in auxiliary contact for holding circuit or -pole contactor versions Easily installed Accessories Auxiliary contact blocks with serrated wiping action Front mount dust tight auxiliary contact blocks Pneumatic time delay blocks Transient voltage surge suppressors Interface modules and electronic timers Mechanical latching blocks Control circuit flexibility The D-Line contactors are available with AC or DC operating coils. Several devices utilize a low consumption DC coil with built-in transient suppression for operation with a low level DC signal from a computer or PLC without need for an interposing relay. Overload relays Class 0 or Class 0 bimetallic overload relays are available up to 0 Amps. They are ambient compensated and are available with or without single phase sensitivity for phase unbalance and phase loss protection. New solid state overload relays are available for 90 to 50 Amp applications. Both bimetallic and solid-state overload relays include the following features: isolated N.C. trip contact and N.O. alarm contacts, Manual or Automatic reset function, tamper resistant window for FLA settings and Test trip button. 7/ Square D All Rights Reserved 3
4 D-Line Contactors, Overload Relays and Accessories Characteristics Type LCkD and LPkD contactors Type Environment Rated insulation voltage (Ui) Rated impulse withstand voltage (Uimp) Conforming to standards LC-D09 LC-D LC-D8 LC-D5 LP-D09 LP-D LP-D8 LP-D5 UL/CSA V To IEC 97--, overvoltage category III, degree of pollution: 3 V Conforming to UL, CSA V Conforming to IEC 97 kv Meets the essential requirements of the LV & EMC directives IEC 97-, 97--, NFC 63-0, VDE 0660, BS 5, JEM 038., EN 6097-, EN Approvals E686 CCN NLDX LR336 Class 3 0 ASE, UL, CSA, DEMKO, NEMKO, SEMKO, FI, Conforming to SNCF, Sichere Trennung recommendations Power connections Protection against direct finger contact IP X Degree of protection c Conforming to VDE 006 Coil connections Protection against direct finger contact IP X Protective treatment Conforming to IEC 68 TH Storage - 60 to + 80 C (-76 to +76 F) Ambient air temperature around the Operation at 80 to 0% nominal control voltage device - 5 to + 55 C (-3 to +3 F) Permissible at nominal control voltage - 0 to + 70 C (-0 to +58 F) Maximum operating altitude Without derating 3000m (8900 ft) Operating positions Without derating ± 30 possible, in relation to normal vertical mounting plane Flame resistance Shock resistance a / sine wave = ms Vibration resistance a 5 to 300 Hz Pole characteristics Conforming to UL 9 V V V V Conforming to IEC Contactor open 0 g 0 g 0 g 8 g Contactor closed 5 g 5 g 5 g 5 g Contactor open g g g g Contactor closed g g g g Number of poles 3 3 or 3 3 or In AC-3, θ 55 C (3 F) A Rated operational current (Ie) In AC-, θ 0 C (0 F) A Rated operational voltage (Ue) Up to V Frequency limits Of the operational current Hz 5 to 00 5 to 00 5 to 00 5 to 00 Rated thermal current (Ith) θ 0 C (0 F) A Rated making capacity ( rms) Conforming to IEC 97- A Rated breaking capacity ( rms) Conforming to IEC 97 Permissible short time rating from cold state, no current flowing for previous 5 minutes, at θ 0 C c Protection provided for the cable c.s.a. indicated on pages 0 and and for cable connections. a In the least favorable direction, without change of contact state (coil supplied at Ue) V V A V For s A For 0 s A For min A For 0 min A By circuit breaker Select circuit breaker in accordance with NEC and local codes Short-circuit protection By fuses Maximum 00% of motor full load Amps Average impedance per pole A Ith and 50 Hz mω Power dissipation per pole for the AC-3 W above operational currents AC- W Square D All Rights Reserved 7/98
5 D-Line Contactors, Overload Relays and Accessories Characteristics LC-D3 LC-D38 LC-D0 LC-D50 LC-D65 LC-D80 LC-D95 LC-D5 LC-D50 LP-D3 LP-D0 LP-D50 LP-D65 LP-D IEC 97-, 97--, NFC 63-0, VDE 0660, BS 5, JEM 038., EN 6097-, EN ASE, UL, CSA, DEMKO, NEMKO, SEMKO, FI, Conforming to SNCF, Sichere Trennung UL, CSA recommendations Protection against direct finger contact IP X Protection against direct finger contact IP X except LP-D0 to D80 TH - 60 to + 80 C (-76 to +76 F) - 5 to + 55 C (-3 to +3 F) - 0 to + 70 C (-0 to +58 F) 3000m (8900 ft) ± 30 possible, in relation to normal vertical mounting plane V V V V V V V V V g 8 g 8 g 8 g 8 g 8 g 8 g 6 g 6 g 5 g 0 g 0 g 0 g 0 g 0 g 0 g 5 g 5 g g g g g g g g g g g g 3 g 3 g 3 g 3 g 3 g g g or 3 3 or 3 or 3 3 or to 00 5 to 00 5 to 00 5 to 00 5 to 00 5 to 00 5 to 00 5 to 00 5 to Select circuit breaker in accordance with NEC and local codes Maximum 00% of motor full load Amps / Square D All Rights Reserved 5
6 D-Line Contactors, Overload Relays and Accessories Characteristics Type LCkD and LPkD contactors Type LC-D09 LC-D LC-D8 LC-D5 Control circuit characteristics Rated control circuit voltage (Uc) 50 or 60 Hz V to 660 Control voltage limits (θ 55 C) 50 or 60 Hz coils 50/60 Hz coils Operational Drop-out Operational Drop-out 0.8 to. Uc 0.3 to 0.6 Uc 0.85 to. Uc at 60 Hz 0.3 to 0.6 Uc 50 Hz coil VA Inrush Cos ϕ /60 Hz coil VA Hz AC 50 Hz coil VA Sealed Cos ϕ /60 Hz coil VA Average consumption at 0 C and at Uc 60 Hz coil VA Inrush Cos ϕ /60 Hz coil VA Hz AC 60 Hz coil VA Sealed Cos ϕ /60 Hz coil VA Heat dissipation 50/60 Hz W to 3 to 3 to 3.5 to 3.5 Operating time c Mechanical durability in millions of operating cycles Maximum operating rate at ambient temperature 55 C Closing C ms to to to 5 to Opening O ms to 9 to 9 to 9 5 to 9 50 or 60 Hz coil /60 Hz coil at 50 Hz In operating cycles per hour c The closing time C is measured from the moment the coil supply is switched on to initial contact of the main poles. The opening time O is measured from the moment the coil supply is switched off to the moment the mains poles separate Square D All Rights Reserved 7/98
7 D-Line Contactors, Overload Relays and Accessories Characteristics LC-D3 LC-D38 LC-D0 LC-D50 LC-D65 LC-D80 LC-D95 LC-D5 LC-D50 to 660 to 660 to to. Uc 0.85 to. Uc 0.3 to 0.6 Uc 0.3 to 0.5 Uc 0.85 to. Uc at 60 Hz 0.8 to.5 Uc at 50/60 Hz 0.3 to 0.6 Uc 0.3 to 0.5 Uc to to to 0 6 to 0 6 to 0 6 to 0 6 to 0 7 to 8 6 to 7 5 to 5 to 0 to 6 0 to 6 0 to 6 0 to 35 0 to 35 0 to 50 5 to 35 5 to 9 5 to 9 8 to 8 to 8 to 6 to 0 6 to 0 6 to 0 0 to / Square D All Rights Reserved 7
8 D-Line Contactors, Overload Relays and Accessories Characteristics Type LP-D09, D, D8 LP-D5, D3 LP-D0, D50, D65 LP-D80 Control circuit characteristics LC-D5 LC-D50 Rated control circuit voltage (Uc) DC V to 0 to 0 to 0 Control voltage limits (θ 55 C) Average consumption at 0 C and at Uc Standard coil 0.8 to. Uc 0.85 to. Uc 0.7 to. Uc Operational Wide range coil 0.7 to.5 Uc 0.75 to. Uc Drop-out 0. to 0.5 Uc 0. to 0.3 Uc 0. to 0. Uc DC Inrush W 9 6 Sealed W 9 6 Closing C ms 0 to 8 5 to 6 85 to 0 95 to 30 5 to 35 Operating time c average at Uc Opening O ms 6 to 8 to 0 to 35 0 to 35 0 to 35 Note: the arcing time depends on the circuit switched by the poles. For normal three-phase applications, arcing time is normally less than 0 ms. The load is isolated from the supply after a time equal to the sum of the opening time and the arcing time. Mechanical durability at Uc In millions of operating cycles Maximum operating rate at ambient temperature 55 C In operating cycles per hour c The operating times depend on the type of contactor electromagnet and its control mode. The closing time C is measured from the moment the coil supply is switched on to initial contact of the main poles. The opening time O is measured from the moment the coil supply is switched off to the moment the mains poles separate Square D All Rights Reserved 7/98
9 D-Line Contactors, Overload Relays and Accessories Characteristics Type LCkD and LPkD contactors Integrated auxiliary contacts Rated operational voltage (Ue) Up to V 690 Conforming to IEC 97- V 000 Rated insulation voltage (Ui) Conforming to UL, CSA V 600 Rated thermal current (Ith) For ambient temperature 0 C (0 F) A 0 Frequency of operational current Hz 5 to 00 U min (minimum voltage) V 7 Minimum switching capacity I min (minimum current) ma 5 Short-circuit protection Conforming to IEC gg fuse: 0 A Rated making capacity Conforming to IEC 97-5-, I rms A 0 AC, 50 DC s A 00 Short time rating Permissible for 500 ms A 0 00 ms A 0 Insulation resistance MΩ > 0 Non-overlap time Guaranteed between N.C. and N.O. contacts ms.5 on energization and on de-energization Operational power of contacts conforming to IEC AC supply categories AC- and AC-5 Electrical durability (up to 3600 operating cycles/hour) on an inductive load such as the coil of an electromagnet: making power (cos ϕ 0.7) = 0 times the power broken (cos ϕ 0.). DC supply category DC-3 Electrical life (up to 00 operating cycles/hour) on an inductive load such as the coil of an electromagnet, without economy resistor, the time constant increasing with the load. V 8 0/ 7 0/30 380/ V million operating cycles VA W million operating cycles VA W million operating cycles VA W Occasional making capacity VA W Breaking limit of contacts for: maximum of 50 operating cycles at 0 s intervals. (power broken = making power x cos 0.7). Electrical durability of contacts: - for million operating cycles (a). - for 3 million operating cycles (b). - for 0 million operating cycles (c). 3 Breaking limit of contacts for: maximum of 0 operating cycles at 0 s intervals and with current passing for 0.5 s per cycle. Thermal limit. Power broken in VA a b c V Power broken in VA a b c V 7/ Square D All Rights Reserved 9
10 D-Line Contactors, Overload Relays and Accessories Characteristics Type LCkD and LPkD contactors Power and control circuit connections Type Power circuit connections Cabling Bus bar connection Control circuit connections Cabling Stranded cable without cable end Flexible cable with cable end Connector type LC-D09 LP-D09 Screw clamp terminals LC-D LP-D LC-D8 LP-D8 LC-D5 LP-D5 conductor AWG conductors AWG conductor mm / /.5/6.5/0 conductors mm / /.5/6.5/6 conductor AWG conductors AWG conductor mm / / /6 /6 conductors mm /.5 /.5 / / conductor AWG conductors AWG Solid cable without cable end conductor mm / /.5/6.5/6 conductors mm / /.5/6.5/6 Phillips head type N N N N Screwdriver Ø Ø 6 Ø 6 Ø 6 Ø 6 Hexagon spanner Tightening torque 7 lb.-in.. Nkm 7 lb.-in.. Nkm 5 lb.-in..7 Nkm Connection by bus bar or ring tongue terminals Bar c.s.a. Lug external Ø mm Screw Ø mm M3.5 M3.5 M3.5 M Phillips head type N N N N Screwdriver Ø Ø 6 Ø 6 Ø 6 Ø 6 Hexagon spanner Tightening torque Stranded cable without cable end Stranded cable with cable end 7 lb.-in.. Nkm Connection by cable Screw clamp terminals 7 lb.-in.. Nkm 5 lb.-in..7 Nkm 5 lb.-in..85 Nkm 5 lb.-in..85 Nkm or conductors AWG conductor mm / / / / conductors mm / / / / conductor mm / / / / conductors mm /.5 /.5 /.5 /.5 conductor mm / / / / Solid cable without cable end conductors mm / / / / Phillips head type N N N N Screwdriver Ø mm Ø 6 Ø 6 Ø 6 Ø 6 Tightening torque 7 lb.-in.. Nkm 7 lb.-in.. Nkm 7 lb.-in.. Nkm Connection by bus bar or ring tongue terminals Lug external Ø mm Screw Ø mm M3.5 M3.5 M3.5 M3.5 Phillips head type N N N N Screwdriver Ø Tightening torque 3/6 in. Ø 6 7 lb.-in.. 3/6 in. Ø 6 7 lb.-in.. 3/6 in. Ø 6 7 lb.-in.. 7 lb.-in.. Nkm 3/6 in. Ø 6 7 lb.-in Square D All Rights Reserved 7/98
11 D-Line Contactors, Overload Relays and Accessories Characteristics LC-D3 LP-D3 LC-D38 LC-D0 LP-D0 LC-D50 LP-D50 LC-D65 LP-D65 LC-D80 LP-D80 LC-D95 LC-D5 LC-D50 Box lug terminals LA9D560 terminals mcm 8-50 mcm mcm mcm.5/0.5/0.5/5.5/5.5/5 /50 /50 0/0 0/0.5/0.5/0.5/6.5/6.5/6 /5 /5 0/0+ 0/50 0/0+ 0/50 8-3/ /0 /0.5/5.5/5.5/5 /50 /50 0/0 0/0.5/6.5/6.5/0.5/0.5/0 /6 /6 0/0+ 0/50 0/0+ 0/ mcm 8-50 mcm mcm mcm.5/0.5/0.5/5.5/5.5/5 /50 /50 0/0 0/0.5/0.5/0.5/6.5/6.5/6 /5 /5 0/0+ 0/50 0/0+ 0/50 N N Ø 6 Ø 6 Ø 6 to Ø 8 Ø 6 to Ø 8 Ø 6 to Ø 8 Ø 6 to Ø 8 Ø 6 to Ø 8 mm mm mm mm mm mm mm 0 lb.-in..5 Nkm.5 Nkm 5 lb.-in. 5 Nkm 5 lb.-in. 5 Nkm 5 lb.-in. 5 Nkm 00 lb.-in. 9 Nkm 9 Nkm 00 lb. in. Nkm Connection by bus bar or ring tongue terminals 3 x 6 3 x 6 5 x 5 5 x M M M5 M6 M6 M6 M6 M8 M8 N N 3/6 in. Ø 6 mm 3/6 in. Ø 6 mm 0 mm 0 mm 3 mm 3 mm lb. in. Nkm Connection by cable Screw clamp terminals / / / / / / / /.5 /.5 / / / / / / / /.5 /.5 / / / / / / / /.5 /.5 /.5 /.5 /.5 /.5 /.5 /.5 /.5 /.5 /.5 / / / / / / / /.5 /.5 / / / / / / / /.5 /.5 N N N N N N N N N Ø 6 Ø 6 Ø 6 Ø 6 Ø 6 Ø 6 Ø 6 Ø 6 Ø 6 7 lb.-in.. Nkm 7 lb.-in.. Nkm 7 lb.-in.. Nkm 7 lb.-in.. Nkm 7 lb.-in.. Nkm 7 lb.-in.. Nkm 7 lb.-in.. Nkm 7 lb.-in.. Nkm Connection by bus bar or ring tongue terminals M3.5 M3.5 M3.5 M3.5 M3.5 M3.5 M3.5 M3.5 M3.5 N N N N N N N N N 3/6 in. Ø 6 7 lb.-in.. 3/6 in. Ø 6 7 lb.-in.. 3/6 in. Ø 6 7 lb.-in.. 3/6 in. Ø 6 7 lb.-in.. 3/6 in. Ø 6 7 lb.-in.. 3/6 in. Ø 6 7 lb.-in.. 3/6 in. Ø 6 7 lb.-in.. 3/6 in. Ø 6 7 lb.-in.. 7 lb.-in.. Nkm 3/6 in. Ø 6 7 lb.-in.. 7/ Square D All Rights Reserved
12 D-Line Contactors, Overload Relays and Accessories Selection Contactors for Motor Control Control Circuit: AC Kilowatt ratings for international applications 3-pole contactors with Fingersafe terminals for power cabling LC-D090kk LC-D50kk LC-D95kk Standard power ratings of 3-phase motors 50/60 Hz in category AC-3 0V 30V 380V 00V 5V 0V 500V 660V 690V Rated operating current in AC-3 0V up to Instantaneous auxiliary contacts * Catalog number. Complete with code indicating control circuit voltage a c DIN rail or screw mounting 000V kw kw kw kw kw kw kw A N/O N/C kg (lb.) Note: 3-pole contactors without auxiliary contacts conform to standard EN 500. Auxiliary contact blocks and modules: see pages to 9. c For LC-D09 to D38: clip-on mounting on 35 mm ( DIN rail AM-DP or screw mounting. For LC-D0 to D95: clip-on mounting on 35 mm ( DIN rail AM-DE or 75 mm ( DIN rail AM-DL or screw mounting. LC-D5 and D50: clip-on mounting on x 35 mm ( DIN rails AM-DP or screw mounting. Weight LC-D0900kk 0.30 (0.75) LC-D090kk q 0.30 (0.75) LC-D090kk q 0.30 (0.75) LC-D00kk 0.35 (0.77) LC-D0kk q 0.35 (0.77) LC-D0kk q 0.35 (0.77) LC-D800kk (0.79) LC-D80kk q (0.8) LC-D80kk q (0.8) LC-D500kk 0.00 (0.89) LC-D50kk q (.8) LC-D50kk q (.8) LC-D300kk 0.55 (.) LC-D30kk q (.) LC-D30kk q 0.555(.3) LC-D380kk (.3) LC-D380kk (.3) LC-D0kk q.00 (3.) LC-D50kk.00 (3.) LC-D65kk.00 (3.) LC-D80kk.590 (3.53) LC-D95kk.60 (3.58) LC-D500kk.0 (5.38) LC-D5000kk.0 (5.) aac Coil Selection Volts LC-D09 to D95 50 Hz B5 D5 E5 F5 M5 P5 U5 Q5 V5 N5 R5 S5 X5 Y5 60 Hz B6 D6 E6 F6 G6 L6 M6 U6 W6 Q6 R6 T6 S6 X6 LC-D09 to D50 (coils D5 and D50 with built-in surge suppression) 50/60 Hz B7 D7 E7 F7 FE7 M7 P7 U7 Q7 V7 N7 R7 T7 S7 Other voltages from to 660 V, see pages 53 to 56. LC-D500kk 998 Square D All Rights Reserved 7/98
13 D-Line Contactors, Overload Relays and Accessories Selection Contactors for Motor Control Control Circuit: AC Horsepower ratings for North American applications 3-pole contactors with Fingersafe terminals for power cabling LC-D090kk LC-D50kk LC-D95kk Maximum horsepower ratings -phase 50/60 Hz 3-phase 50/60 Hz 5/ 0V 30/ 0V 00/ 08V 0/ 0V 60/ 80V 575V 600V Maximum inductive current in AC-3 category 600V Instantaneous auxiliary contacts Catalog number. Complete with code indicating control circuit voltage a c DIN rail or screw mounting hp hp hp hp hp hp A N/O N/C kg (lb.) Note: 3-pole contactors without auxiliary contacts conform to standard EN 500. Auxiliary contact blocks and modules: see pages to 9. c For LC-D09 to D38: clip-on mounting on 35 mm ( DIN rail AM-DP or screw mounting. For LC-D0 to D95: clip-on mounting on 35 mm ( DIN rail AM-DE or 75 mm ( DIN rail AM-DL or screw mounting. LC-D5 and D50: clip-on mounting on x 35 mm ( DIN rails AM-DP or screw mounting. Weight LC-D0900kk 0.30 (0.75) LC-D090kk q 0.30 (0.75) LC-D090kk q 0.30 (0.75) LC-D00kk 0.35 (0.77) LC-D0kk q 0.35 (0.77) LC-D0kk q 0.35 (0.77) LC-D800kk (0.79) LC-D80kk q (0.8) LC-D80kk q (0.8) LC-D500kk 0.00 (0.89) LC-D50kk q (.8) LC-D50kk q (.8) LC-D300kk 0.55 (.) LC-D30kk q (.) LC-D30kk q 0.555(.3) Not UL listed or CSA certified LC-D380kk (.3) 38 Not for North American applications LC-D380kk (.3) LC-D0kk q.00 (3.) LC-D50kk.00 (3.) LC-D65kk.00 (3.) LC-D80kk.590 (3.53) Not UL listed or CSA certified Not for North American applications 95 LC-D95kk.60 (3.58) LC-D500kk.0 (5.38) LC-D5000kk.0 (5.) aac Coil Selection Volts LC-D09 to D95 50 Hz B5 D5 E5 F5 M5 P5 U5 Q5 V5 N5 R5 S5 X5 Y5 60 Hz B6 D6 E6 F6 G6 L6 M6 U6 W6 Q6 R6 T6 S6 X6 LC-D09 to D50 (coils D5 and D50 with built-in surge suppression) 50/60 Hz B7 D7 E7 F7 FE7 M7 P7 U7 Q7 V7 N7 R7 T7 S7 Other voltages from to 660 V, see pages 53 to 56. LC-D500kk 7/ Square D All Rights Reserved 3
14 D-Line Contactors, Overload Relays and Accessories Selection Contactors for Motor Control Control Circuit: AC Kilowatt ratings for international applications 3-pole contactors for ring-tongue terminals or bus bar power connections LC-D5006kk Standard power ratings of 3-phase motors 50/60 Hz in category AC-3 0V 30V 380V 00V 5V 0V 500V 660V 690V Rated operating current in AC-3 0V up to Instantaneous auxiliary contacts Catalog number. Complete with code indicating control circuit voltage a c DIN rail or screw mounting 000V kw kw kw kw kw kw kw A N/O N/C kg (lb.) Weight LC-D09006kk (0.7) LC-D0906kk (0.7) LC-D0906kk (0.7) LC-D006kk (0.7) LC-D06kk (0.7) LC-D06kk (0.7) LC-D8006kk 0.35 (0.77) LC-D806kk 0.35 (0.78) LC-D806kk 0.35 (0.78) LC-D5006kk (0.87) LC-D506kk 0.50 (.5) LC-D506kk 0.50 (.5) LC-D3006kk (.8) LC-D306kk 0.55 (.) LC-D306kk 0.55 (.) LC-D3806kk 0.55 (.) LC-D3806kk 0.55 (.) LC-D06kk.30 (.93) LC-D506kk.30 (.93) LC-D656kk.30 (.93) LC-D806kk.600 (3.55) LC-D956kk.600 (3.55) LC-D5006kk.0 (.69) LC-D50006kk.30 (.69) 3-pole contactors for connection with slip-on connectors For contactors LC-D09 and LC-D only, replace the last digit 6 in the above catalog numbers, with a 9. Example: LC-D0906kk becomes LC-D0909kk. These contactors include slip-on connectors: UL Recognized E686 NLDX x 6.35 mm (0.5 in.) on the power poles and x 6.35 mm (0.5 in.) on the coil terminals. Note: 3-pole contactors without auxiliary contacts conform to standard EN 500. Auxiliary contact blocks and modules: see pages to 9. c For LC-D09 to D38: clip-on mounting on 35 mm ( DIN rail AM-DP or screw mounting. For LC-D0 to D95: clip-on mounting on 35 mm ( DIN rail AM-DE or 75 mm ( DIN rail AM-DL or screw mounting. LC-D5 and D50: clip-on mounting on x 35 mm ( DIN rails AM-DP or screw mounting. a Standard control circuit voltages see page. 998 Square D All Rights Reserved 7/98
15 D-Line Contactors, Overload Relays and Accessories Selection Contactors for Motor Control Control Circuit: AC Horsepower ratings for North American applications 3-pole contactors for ring-tongue terminals or bus bar power connections LC-D5006kk Maximum horsepower ratings -phase 50/60 Hz 3-phase 50/60 Hz 5/ 0V 30/ 0V 00/ 08V 0/ 0V 60/ 80V 575V 600V Maximum inductive current in AC-3 category 600V Instantaneous auxiliary contacts Catalog number. Complete with code indicating control circuit voltage a c DIN rail or screw mounting hp hp hp hp hp hp A N/O N/C kg (lb.) Weight LC-D09006kk (0.7) LC-D0906kk (0.7) LC-D0906kk (0.7) LC-D006kk (0.7) LC-D06kk (0.7) LC-D06kk (0.7) LC-D8006kk 0.35 (0.77) LC-D806kk 0.35 (0.78) LC-D806kk 0.35 (0.78) LC-D5006kk (0.87) LC-D506kk 0.50 (.5) LC-D506kk 0.50 (.5) LC-D3006kk (.8) LC-D306kk 0.55 (.) LC-D306kk 0.55 (.) Not UL listed or CSA certified LC-D3806kk 0.55 (.) 38 Not for North American applications LC-D3806kk 0.55 (.) LC-D06kk.30 (.93) LC-D506kk.30 (.93) LC-D656kk.30 (.93) LC-D806kk.600 (3.55) Not UL listed or CSA certified Not for North American applications 95 LC-D956kk.600 (3.55) LC-D5006kk.0 (.69) LC-D50006kk.30 (.69) 3-pole contactors for connection with slip-on connectors For contactors LC-D09 and LC-D only, replace the last digit 6 in the above catalog numbers, with a 9. Example: LC-D0906kk becomes LC-D0909kk. These contactors include slip-on connectors: UL Recognized E686 NLDX x 6.35 mm (0.5 in.) on the power poles and x 6.35 mm (0.5 in.) on the coil terminals. Note: 3-pole contactors without auxiliary contacts conform to standard EN 500. Auxiliary contact blocks and modules: see pages to 9. c For LC-D09 to D38: clip-on mounting on 35 mm ( DIN rail AM-DP or screw mounting. For LC-D0 to D95: clip-on mounting on 35 mm ( DIN rail AM-DE or 75 mm ( DIN rail AM-DL or screw mounting. LC-D5 and D50: clip-on mounting on x 35 mm ( DIN rails AM-DP or screw mounting. a Standard control circuit voltages see page 3. 7/ Square D All Rights Reserved 5
16 D-Line Contactors, Overload Relays and Accessories Selection Contactors for Motor Control Control Circuit: DC Kilowatt ratings for international applications 3-pole contactors with Finger-safe terminals for power cabling LC-D090kk LC-D50kk Standard power ratings of 3-phase motors 50/60 Hz in category AC-3 0V 30V 380V 00V 5V 0V 500V 660V 690V Rated operat. current in AC-3 0V up to Instantaneous auxiliary contacts Catalog number. Complete with code indicating control circuit voltage a c DIN rail or screw mounting 000V kw kw kw kw kw kw kw A N/O N/C kg (lb.) Weight LP-D090kk 0.60 (.) LP-D090kk 0.60 (.) LP-D0kk 0.60 (.) LP-D0kk 0.60 (.) LP-D80kk (.) LP-D80kk (.) LP-D50kk 0.95 (.05) LP-D50kk 0.95 (.05) LP-D30kk (.) LP-D30kk (.) LP-D0kk.85 (.85) LP-D50kk.85 (.85) LP-D65kk.90 (.87) LP-D80kk.55 (5.6) LC-D500kk.0 (5.) LC-D5000kk.0 (5.) Note: Auxiliary contact blocks and modules: see pages to 9. c For LP-D09 to D3: clip-on mounting on 35 mm ( DIN rail AM-DP or screw mounting. For LP-D0 to D80: clip-on mounting on 75 mm ( DIN rail AM-DL or screw mounting. LC-D5 and D50: clip-on mounting on x 35 mm ( DIN rails AM-DP or screw mounting. adc Coil Selection Volts LP-D09 to D3 U 0.8 to. Uc JD BD CD ED ND SD FD GD MD UD RD LC-D65kk U 0.7 to.5 Uc JW BW CW EW SW FW MW U 0.7 to.5 Uc JW BW CW EW SW FW MW LP-D0 to D80 U 0.85 to. Uc JD BD CD ED ND SD FD GD MD UD RD U 0.75 to. Uc JW BW CW EW SW FW MW LC-D5 and D50 (coils with built-in surge suppression) U 0.7 to. Uc BD ED ND SD FD GD MD UD RD Other voltages from to 0 V, see pages 57 to 60. LC-D500kk Square D All Rights Reserved 7/98
17 D-Line Contactors, Overload Relays and Accessories Selection Contactors for Motor Control Control Circuit: DC Horsepower ratings for North American applications 3-pole contactors with Finger-safe terminals for power cabling LC-D090kk LC-D50kk Maximum horsepower ratings -phase 50/60 Hz 3-phase 50/60 Hz 5/ 0V 30/ 0V 00/ 08V 0/ 0V 60/ 80V 575V 600V Maximum inductive current in AC-3 category 600V Instantaneous auxiliary contacts Catalog number. Complete with code indicating control circuit voltage a c DIN rail or screw mounting hp hp hp hp hp hp A N/O N/C kg (lb.) Weight LP-D090kk 0.60 (.) LP-D090kk 0.60 (.) LP-D0kk 0.60 (.) LP-D0kk 0.60 (.) LP-D80kk (.) LP-D80kk (.) LP-D50kk 0.95 (.05) LP-D50kk 0.95 (.05) LP-D30kk (.) LP-D30kk (.) LP-D0kk.85 (.85) LP-D50kk.85 (.85) LP-D65kk.90 (.87) LP-D80kk.55 (5.6) LC-D500kk.0 (5.) LC-D5000kk.0 (5.) Note: Auxiliary contact blocks and modules: see pages to 9. c For LP-D09 to D3: clip-on mounting on 35 mm ( DIN rail AM-DP or screw mounting. For LP-D0 to D80: clip-on mounting on 75 mm ( DIN rail AM-DL or screw mounting. LC-D5 and D50: clip-on mounting on x 35 mm ( DIN rails AM-DP or screw mounting. adc Coil Selection Volts LP-D09 to D3 U 0.8 to. Uc JD BD CD ED ND SD FD GD MD UD RD LC-D65kk U 0.7 to.5 Uc JW BW CW EW SW FW MW U 0.7 to.5 Uc JW BW CW EW SW FW MW LP-D0 to D80 U 0.85 to. Uc JD BD CD ED ND SD FD GD MD UD RD U 0.75 to. Uc JW BW CW EW SW FW MW LC-D5 and D50 (coils with built-in surge suppression) U 0.7 to. Uc BD ED ND SD FD GD MD UD RD Other voltages from to 0 V, see pages 57 to 60. LC-D500kk 7/ Square D All Rights Reserved 7
18 D-Line Contactors, Overload Relays and Accessories Selection Contactors for Motor Control Control Circuit: DC Kilowatt ratings for international applications 3-pole contactors for ring-torque terminals or bus bar power connections LC-D5006kk Standard power ratings of 3-phase motors 50/60 Hz in category AC-3 0V 30V 380V 00V 5V 0V 500V 660V 690V Rated operat. current in AC-3 0V up to Instantaneous auxiliary contacts Catalog number. Complete with code indicating control circuit voltage a c DIN rail or screw mounting 000V kw kw kw kw kw kw kw A N/O N/C kg (lb.) Weight LP-D0906kk (.0) LP-D0906kk (.0) LP-D06kk (.0) LP-D06kk (.0) LP-D806kk 0.60 (.) LP-D806kk 0.60 (.) LP-D506kk 0.95 (.03) LP-D506kk 0.95 (.03) LP-D306kk 0.90 (.09) LP-D306kk 0.90 (.09) LP-D06kk.75 (.83) LP-D506kk.75 (.83) LP-D656kk.80 (.8) LP-D806kk.55 (5.59) LC-D5006kk.30 (.73) LC-D50006kk.30 (.73) 3-pole contactors for connection with slip-on connectors For contactors LC-D09 and LC-D only, replace the last digit 6 in the above catalog numbers, with a 9. Example: LC-D0906kk becomes LC-D0909kk. These contactors include slip-on connectors: UL Recognized E686 NLDX x 6.35 mm (0.5 in.) on the power poles and x 6.35 mm (0.5 in.) on the coil terminals. Note: Auxiliary contact blocks and modules: see pages to 9. c For LC-D09 to D3: clip-on mounting on 35 mm ( DIN rail AM-DP or screw mounting. For LC-D0 to D80: clip-on mounting on 75 mm ( DIN rail AM-DL or screw mounting. LC-D5 and D50: clip-on mounting on x 35 mm ( DIN rails AM-DP or screw mounting. a Standard control circuit voltages see page Square D All Rights Reserved 7/98
19 D-Line Contactors, Overload Relays and Accessories Selection Contactors for Motor Control Control Circuit: DC Horsepower ratings for North American applications 3-pole contactors for ring-torque terminals or bus bar power connections Maximum horsepower ratings -phase 50/60 Hz 3-phase 50/60 Hz 5/ 0V 30/ 0V 00/ 08V 0/ 0V 60/ 80V 575V 600V Maximum inductive current in AC-3 category 600V Instantaneous auxiliary contacts Catalog number. Complete with code indicating control circuit voltage a c DIN rail or screw mounting Weight hp hp hp hp hp hp A N/O N/C kg (lb.) LC-D5006kk LP-D0906kk (.0) LP-D0906kk (.0) LP-D06kk (.0) LP-D06kk (.0) LP-D806kk 0.60 (.) LP-D806kk 0.60 (.) LP-D506kk 0.95 (.03) LP-D506kk 0.95 (.03) LP-D306kk 0.90 (.09) LP-D306kk 0.90 (.09) LP-D06kk.75 (.83) LP-D506kk.75 (.83) LP-D656kk.80 (.8) LP-D806kk.55 (5.59) LC-D5006kk.30 (.73) LC-D50006kk.30 (.73) 3-pole contactors for connection with slip-on connectors For contactors LC-D09 and LC-D only, replace the last digit 6 in the above catalog numbers, with a 9. Example: LC-D0906kk becomes LC-D0909kk. These contactors include slip-on connectors: UL Recognized E686 NLDX x 6.35 mm (0.5 in.) on the power poles and x 6.35 mm (0.5 in.) on the coil terminals. Note: Auxiliary contact blocks and modules: see pages to 9. c For LC-D09 to D3: clip-on mounting on 35 mm ( DIN rail AM-DP or screw mounting. For LC-D0 to D80: clip-on mounting on 75 mm ( DIN rail AM-DL or screw mounting. LC-D5 and D50: clip-on mounting on x 35 mm ( DIN rails AM-DP or screw mounting. a Standard control circuit voltages see page 7. 7/ Square D All Rights Reserved 9
20 D-Line Contactors, Overload Relays and Accessories Selection Resistive Loads Control circuit: AC 3 or -pole contactors with Fingersafe terminals for power cabling Non-inductive loads maximum current (θ 55 C) Utilization category AC- Number of poles Instantaneous auxiliary contacts Catalog number. Complete with code indicating control circuit voltage a. c DIN rail or screw mounting Weight LC-D00kk LC-D6500kk LC-D500kk A N/O N/C N/O N/C kg (lb.) LC-D0900kk 0.30 (0.75) or LC-D00kk q 0.35 (0.77) LC-D090kk 0.30 (0.75) 3 or LC-D0kk q 0.35 (0.77) 5 LC-D090kk 0.30 (0.75) or LC-D0kk q 0.35 (0.77) LC-D00kk (0.77) LC-D008kk (0.77) LC-D800kk (0.79) 3 3 LC-D80kk (0.8) LC-D80kk (0.8) LC-D500kk 0.00 (0.89) 3 LC-D50kk (.8) 0 LC-D50kk (.8) LC-D500kk (.8) LC-D5008kk (.9) LC-D300kk 0.55 (.) LC-D30kk (.3) 50 3 or LC-D380kk LC-D30kk (.3) or LC-D380kk 3 LC-D0kk.00 (3.) 60 LC-D000kk.0 (3.0) LC-D0008kk.50 (3.) LC-D50kk.00 (3.) 3 or LC-D65kk q.00 (3.) 80 LC-D6500kk.0 (3.0) LC-D65008kk.50 (3.) LC-D80kk.590 (3.53) 3 or LC-D95kk q.60 (3.58) 5 LC-D8000kk.760 (3.9) LC-D80008kk.80 (.09) LC-D500kk.0 (5.38) 3 00 LC-D5000kk q.0 (5.) or LC-D500kk.860 (6.35) Note: 3-pole contactors without auxiliary contacts conform to standard EN 500. Auxiliary contact blocks and modules: see pages???? to?????. c For LC-D09 to D38: clip-on mounting on 35 mm ( DIN rail AM-DP or screw mounting. For LC-D0 to D95: clip-on mounting on 35 mm ( DIN rail AM-DE or 75 mm ( DIN rail AM-DL or screw mounting. LC-D5 and D50: clip-on mounting on x 35 mm ( DIN rails AM-DP or screw mounting. aac Coil Selection Volts LC-D09 to D95 50 Hz B5 D5 E5 F5 G5 M5 P5 U5 Q5 V5 N5 R5 S5 X5 Y5 60 Hz B6 D6 E6 F6 G6 L6 M6 U6 W6 Q6 R6 T6 S6 X6 LC-D09 to D50 (coils D5 and D50 with built-in surge suppression) 50/60 Hz B7 D7 E7 F7 FE7 M7 P7 U7 Q7 V7 N7 R7 T7 Other voltages from to 660 V, see pages 53 to 56. q Selection according to number of operating cycles, see AC- curve in IEC Contactors Selection Guide 850CT Square D All Rights Reserved 7/98
21 Control Circuit: AC D-Line Contactors, Overload Relays and Accessories Selection Resistive Loads 3 or -pole contactors for ring tongue terminals or bus bar power connections Non-inductive loads maximum current (θ 55 C) Utilization category AC- Number of poles Instantaneous auxiliary contacts Catalog number. Complete with code indicating control circuit voltage a. c DIN rail or screw mounting Weight LC-D5006kk A N/O N/C N/O N/C kg (lb.) LC-D09006kk (0.7) or LC-D006kk q (0.7) LC-D0906kk (0.7) 3 or LC-D06kk q (0.7) 5 LC-D0906kk (0.7) or LC-D06kk q (0.7) LC-D006kk 0.30 (0.75) LC-D0086kk 0.30 (0.75) LC-D8006kk 0.35 (0.77) 3 3 LC-D806kk 0.35 (0.78) LC-D806kk 0.35 (0.78) LC-D5006kk (0.87) 3 LC-D506kk 0.50 (.5) 0 LC-D506kk 0.50 (.5) LC-D5006kk 0.50 (.5) LC-D50086kk 0.55 (.7) LC-D3006kk (.9) LC-D306kk 0.55 (.) 50 3 or LC-D3806kk 0.55 (.) LC-D306kk 0.55 (.) or LC-D3806kk 0.55 (.) 3 LC-D06kk.30 (.93) 60 LC-D0006kk.30 (3.8) LC-D00086kk.0 (3.0) LC-D506kk.30 (.93) 3 or LC-D656kk q.30 (.93) 80 LC-D65006kk.30 (3.8) LC-D650086kk.0 (3.0) LC-D806kk.600 (3.55) 3 or LC-D956kk q.600 (3.55) 5 LC-D80006kk.750 (3.89) LC-D800086kk.830 (.07) LC-D5006kk.0 (.68) 3 00 or LC-D50006kk.30 (.73) LC-D5006kk q.50 (5.) 3 or -pole contactors for connection with slip-on connectors For contactors LC-D09 and LC-D only, replace the last digit 6 in the above catalog numbers, with a 9. Example: LC-D0906kk becomes LC-D0909kk. These contactors include slip-on connectors: UL Recognized E686 NLDX x 6.35 mm (0.5 in.) on the power poles and x 6.35 mm (0.5 in.) on the coil terminals. Note: 3-pole contactors without auxiliary contacts conform to standard EN 500. Auxiliary contact blocks and modules: see pages to 9. c For LC-D09 to D38: clip-on mounting on 35 mm ( DIN rail AM-DP or screw mounting. For LC-D0 to D95: clip-on mounting on 35 mm ( DIN rail AM-DE or 75 mm ( DIN rail AM-DL or screw mounting. For LC-D5 and D50: clip-on mounting on x 35 mm ( DIN rails AM-DP or screw mounting. a Standard control circuit voltages: see page 0. q Selection according to number of operating cycles, see AC- curve in IEC Contactors Selection Guide 850CT980. 7/ Square D All Rights Reserved
22 D-Line Contactors, Overload Relays and Accessories Selection Contactors for Resistive Loads Control Circuit: DC 3 or -pole contactors with Fingersafe terminals for power cabling Non-inductive loads maximum current (q 55 C) Utilization category AC- Number of poles Instantaneous auxiliary contacts Catalog number. Complete with code indicating control circuit voltage a. c DIN rail or screw mounting Weight A N/O N/C N/O N/C kg (lb.) LC-D00kk LC-D6500kk LP-D090kk 0.60 (.) or LP-D0kk q 0.60 (.) 3 LP-D090kk 0.60 (.) 5 or LP-D0kk q 0.60 (.) LP-D00kk 0.60 (.) or LP-D008kk 0.60 (.) LP-D80kk (.) LP-D80kk (.) LP-D50kk 0.95 (.05) LP-D50kk 0.95 (.05) LP-D500kk (.07) LP-D5008kk (.07) LP-D30kk (.) 50 3 LP-D30kk (.) 3 LP-D0kk.85 (.85) 60 LP-D000kk.05 (.90) LP-D0008kk.00 (.88) LP-D50kk.85 (.85) 3 or LP-D65kk q.90 (.86) 80 LP-D6500kk.0 (.9) LP-D65008kk.0 (.93) 3 LP-D80kk.55 (5.6) 5 LP-D8000kk.695 (5.99) LP-D80008kk.90 (6.7) LC-D500kk.0 (5.) 3 00 or LC-D5000kk q.0 (5.) LC-D500kk.900 (6.) Auxiliary contact blocks and modules: see pages???? to?????. c For LC-D09 to D3: clip-on mounting on 35 mm ( DIN rail AM-DP or screw mounting. For LC-D0 to D80: clip-on mounting on 75 mm ( DIN rail AM-DL or screw mounting. For LC-D5 and D50: clip-on mounting on x 35 mm ( DIN rails AM-DP or screw mounting. LC-D500kk a DC Coil Selection Volts LP-D09 to D3 U 0.8 to. Uc JD BD CD ED ND SD FD GD MD UD RD U 0.7 to.5 Uc JW BW CW EW SW FW MW LP-D0 to D80 U 0.85 to. Uc JD BD CD ED ND SD FD GD MD UD RD U 0.75 to. Uc JW BW CW EW SW FW MW LC-D5 and D50 (coils with built-in surge suppression) U 0.7 to. Uc BD ED ND SD FD GD MD UD RD Other voltages from to 0 V, see pages 57 to 60. q Selection according to number of operating cycles, see AC- curve in IEC Contactors Selection Guide 850CT Square D All Rights Reserved 7/98
23 Control Circuit: DC D-Line Contactors, Overload Relays and Accessories Selection Contactors for Resistive Loads 3 or -pole contactors for ring tongue terminals or bus bar power connections Non-inductive loads maximum current (θ 55 C) Utilization category AC- Number of poles Instantaneous auxiliary contacts Catalog number. Complete with code indicating control circuit voltage a. c DIN rail or screw mounting Weight LC-D5006kk A N/O N/C N/O N/C kg (lb.) LP-D0906kk (.0) or LP-D06kk q (.0) 3 LP-D0906kk (.0) 5 or LPD06kk q (.0) LP-D006kk (.0) LP-D0086kk (.0) LP-D806kk 0.60 (.) LP-D806kk 0.60 (.) LP-D506kk 0.95 (.03) LP-D506kk 0.95 (.03) LP-D5006kk 0.90 (.0) LP-D50086kk 0.90 (.0) LP-D306kk 0.90 (.09) 50 3 LP-D306kk 0.90 (.09) 3 LP-D06kk.75 (.83) 60 LP-D0006kk.90 (.87) LP-D00086kk.90 (.87) LP-D506kk.75 (.83) 3 or LP-D656kk q.80 (.8) 80 LP-D65006kk.00 (.89) LP-D650086kk.0 (.9) 3 LP-D806kk.55 (5.59) 5 LP-D80006kk.680 (5.95) LP-D800086kk.900 (6.) LC-D5006kk.30 (.73) 3 00 or LC-D50006kk q.30 (.73) LC-D5006kk.70 (5.9) 3 or -pole contactors for connection with slip-on connectors For contactors LC-D09 and LC-D only, replace the last digit 6 in the above catalog numbers, with a 9. Example: LC-D0906kk becomes LC-D0909kk. These contactors include slip-on connectors: UL Recognized E686 NLDX x 6.35 mm (0.5 in.) on the power poles and x 6.35 mm (0.5 in.) on the coil terminals. Note: Auxiliary contact blocks and modules: see pages to 9. c For LC-D09 to D3: clip-on mounting on 35 mm ( DIN rail AM-DP or screw mounting. For LC-D0 to D80: clip-on mounting on 75 mm ( DIN rail AM-DL or screw mounting. For LC-D5 and D50: clip-on mounting on x 35 mm ( DIN rails AM-DP or screw mounting. a Standard control circuit voltages, see page????. q Selection according to number of operating cycles, see AC- curve in IEC Contactors Selection Guide 850CT980. 7/ Square D All Rights Reserved 3
24 D-Line Contactors, Overload Relays and Accessories Selection Reversing Contactors for Motor Control Control Circuit: AC Kilowatt ratings for international applications, pre-assembled, horizontally mounted 3-pole reversing contactors with Fingersafe terminals for power cabling Includes pre-wired power connections q f Standard power ratings of 3-phase motors 50/60 Hz in category AC-3 Rated operational current in AC-3 Instantantaneous auxiliary contacts per contactor Contactors supplied with coils Catalog number. Complete with code indicating control circuit voltage a DIN rail or screw mounting c Weight LC-D0kk LC-D50kk 0 V 30 V 380 V 00 V 5 V 0 V 500 V 660 V 690 V 000 V 0 V up to kw kw kw kw kw kw kw A N/O N/C kg (lb.) LC-D090kk q (.55) LC-D090kk f LC-D0kk q (.55) LC-D0kk f LC-D80kk q (.67) LC-D80kk f LC-D50kk q.00 (.) LC-D50kk f LC-D30kk q.00 (.67) LC-D30kk f LC-D380kk q.00 (.67) LC-D0kk q.00 (5.33) LC-D50kk q.00 (5.33) LC-D65kk q.00 (5.33) LC-D80kk q 3.00 (7.) LC-D95kk q 3.00 (7.) LC-D500kk f (.) LC-D5000kk f (.) Accessories (to be ordered separately) Auxiliary contact blocks and add-on modules, see pages to 9. c LC-D09 to D38: clip-on mounting on 35 mm ( DIN rail AM-DP or screw mounting. LC-D0 to D95: clip-on mounting on 35 mm ( DIN rail AM-DE or 75 mm ( DIN rail AM-DL or screw mounting. LC-D5 and D50: clip-on mounting on x 35 mm ( DIN rails AM-DP or screw mounting. aac Coil Selection Volts LC-D09 to D95 50 Hz B5 D5 E5 F5 G5 M5 P5 U5 Q5 V5 N5 R5 S5 Y5 60 Hz B6 D6 E6 F6 G6 L6 M6 U6 W6 Q6 R6 T6 S6 LC-D09 to D50 (coils D5 and D50 with built-in surge suppression) 50/60 Hz B7 D7 E7 F7 FE7 M7 P7 U7 Q7 V7 N7 R7 T7 q Includes mechanical interlock (type LA9Dkk978) without electrical contacts. Installer to complete wiring for electronically interlocking contactor operating coils by utilizing a N.C. auxiliary contact integrated in the contactor or optional LADN or LA8DN type auxiliary contact block. f Included with electrical contacts integrated in mechanical interlock (type LA9Dkk0). 998 Square D All Rights Reserved 7/98
25 D-Line Contactors, Overload Relays and Accessories Selection Reversing Contactors for Motor Control Control Circuit: AC Horsepower ratings for North American applications, 3-pole reversing contactors with Fingersafe terminals for power cabling Pre-wired power connections q f LC-D0kk LC-D50kk Maximum horsepower ratings Maximum inductive current in AC-3 category 600 V Instantantaneous auxiliary contacts per contactor Contactors supplied with coils Catalog number. Complete with code indicating control circuit voltage a DIN rail or screw mounting c -phase 50/60 Hz 3-phase 50/60 Hz hp hp hp hp hp hp A N/O N/C kg (lb.) LC-D090kk q (.55) LC-D090kk f LC-D0kk q (.55) LC-D0kk f LC-D80kk q (.67) LC-D80kk f LC-D50kk q.00 (.) LC-D50kk f LC-D30kk q.00 (.67) LC-D30kk f Not UL listed or CSA certified Not for North American applications 38 LC-D380kk q.00 (.67) LC-D0kk q.00 (5.33) LC-D50kk q.00 (5.33) LC-D65kk q.00 (5.33) LC-D80kk q 3.00 (7.) Not UL listed or CSA certified Not for North American applications 95 LC-D95kk q 3.00 (7.) LC-D500kk f (.) LC-D5000kk f (.) Weight Accessories (to be ordered separately) Auxiliary contact blocks and add-on modules, see pages???? to????. c LC-D09 to D38: clip-on mounting on 35 mm ( DIN rail AM-DP or screw mounting. LC-D0 to D95: clip-on mounting on 35 mm ( DIN rail AM-DE or 75 mm ( DIN rail AM-DL or screw mounting. LC-D5 and D50: clip-on mounting on x 35 mm ( DIN rails AM-DP or screw mounting. aac Coil Selection Volts LC-D09 to D95 50 Hz B5 D5 E5 F5 G5 M5 P5 U5 Q5 V5 N5 R5 S5 Y5 60 Hz B6 D6 E6 F6 G6 L6 M6 U6 W6 Q6 R6 T6 S6 LC-D09 to D50 (coils D5 and D50 with built-in surge suppression) 50/60 Hz B7 D7 E7 F7 FE7 M7 P7 U7 Q7 V7 N7 R7 T7 q Includes mechanical interlock (type LA9Dkk978) without electrical contacts. Installer to complete wiring for switching contactor operating coils by utilizing a N.C. auxiliary contact integrated in the contactor or optional LADN or LA8DN type auxiliary contact block. f Included with electrical contacts integrated in mechanical interlock (type LA9Dkk0) and pre-wired for switching contactor operating coils. 7/ Square D All Rights Reserved 5
26 D-Line Contactors, Overload Relays and Accessories Selection Reversing Contactors for Motor Control Control Circuit: AC Kilowatt ratings for international applications 3-pole reversing contactors for ring tongue terminals or bus bar power connections Includes pre-wired power connections q f Standard power ratings of 3-phase motors 50/60 Hz in category AC-3 Rated operational current in AC-3 Instantantaneous auxiliary contacts per contactor Contactors supplied with coils Catalog number. Complete with code indicating control circuit voltage a DIN rail or screw mounting c Weight 0 V 30 V 380 V 00 V 5 V 0 V 500 V 660 V 690 V 000 V 0 V up to kw kw kw kw kw kw kw A N/O N/C kg (lb.) LC-D0906kk q (.55) LC-D096kk f LC-D06kk q (.55) LC-D6kk f LC-D806kk q (.67) LC-D86kk f LC-D506kk q.00 (.) LC-D56kk f LC-D306kk q.00 (.67) LC-D36kk f LC-D3806kk q.00 (.67) LC-D5006kk f (3.) LC-D50006kk f (3.) 3-pole reversing contactors for connection with slip-on connectors Power connections to be made by the customer For contactors LC-D09 and LC-D only, replace the last digit 6 in the above catalog numbers, with a 9. Example: LC-D0906kk becomes LC-D0909kk. These contactors include slip-on connectors: UL Recognized E686 NLDX x 6.35 mm (0.5 in.) on the power poles and x 6.35 mm (0.5 in.) on the coil terminals. Accessories (to be ordered separately) Auxiliary contact blocks and add-on modules, see pages to 9. c LC-D09 to D38: clip-on mounting on 35 mm ( DIN rail AM-DP or screw mounting. LC-D5 and D50: clip-on mounting on x 35 mm ( DIN rails AM-DP or screw mounting. a Standard control circuit voltages, see page. q Includes mechanical interlock (type LA9Dkk978) without electrical contacts. Installer to complete wiring for electrically interlocking contactor operating coils by utilizing a N.C. auxiliary contact integrated in the contactor or optional LADN or LA8DN type auxiliary contact block. f Included with electrical contacts integrated in mechanical interlock (type LA9Dkk0) Square D All Rights Reserved 7/98
27 Horsepower ratings for North American applications Control Circuit: AC Selection Reversing Contactors for Motor Control 3-pole reversing contactors ring tongue terminals or bus bar power connections Pre-wired power connections q f Maximum horsepower ratings -phase 50/60 Hz 3-phase 50/60 Hz Maximum inductive current in AC-3 category 600 V Instantantaneous auxiliary contacts per contactor Contactors supplied with coils Catalog number. Complete with code indicating control circuit voltage a DIN rail or screw mounting c Weight hp hp hp hp hp hp A N/O N/C kg (lb.) LC-D0906kk q (.55) LC-D096kk f LC-D06kk q (.55) LC-D6kk f LC-D806kk q (.67) LC-D86kk f LC-D506kk q.00 (.) LC-D56kk f LC-D306kk q.00 (.67) LC-D36kk f Not UL listed or CSA certified Not for North American applications 38 LC-D3806kk q.00 (.67) LC-D5006kk f (3.) LC-D50006kk f (3.) 3-pole reversing contactors for connection with slip-on connectors Power connections to be made by the customer For contactors LC-D09 and LC-D only, replace the last digit 6 in the above catalog numbers, with a 9. Example: LC-D0906kk becomes LC-D0909kk. These contactors include slip-on connectors: UL Recognized E686 NLDX x 6.35 mm (0.5 in.) on the power poles and x 6.35 mm (0.5 in.) on the coil terminals. Accessories (to be ordered separately) Auxiliary contact blocks and add-on modules, see pages to 9. c LC-D09 to D38: clip-on mounting on 35 mm ( DIN rail AM-DP or screw mounting. LC-D5 and D50: clip-on mounting on x 35 mm ( DIN rails AM-DP or screw mounting. a Standard control circuit voltages, see page 5. q Includes mechanical interlock (type LA9Dkk978) without electrical contacts. Installer to complete wiring for electrically interlocking contactor operating coils by utilizing a N.C. auxiliary contact integrated in the contactor or optional LADN or LA8DN type auxiliary contact block. f Included with electrical contacts integrated in mechanical interlock (type LA9Dkk0). 7/ Square D All Rights Reserved 7
28 Selection Reversing Contactors for Motor Control Control Circuit: DC Kilowatt ratings for international applications 3-pole reversing contactors with Finger-safe terminals for power cabling Includes pre-wired power connections q LP-D090kk LP-D50kk Standard power ratings of 3-phase motors 50/60 Hz in category AC-3 0 V 30 V 380 V 00 V 5 V 0 V 500 V 660 V 690 V Rated operational current in AC-3 0 V up to Instantantaneous auxiliary contacts per contactor Contactors supplied with coils Catalog number. Complete with code indicating control circuit voltage a DIN rail or screw mounting c kw kw kw kw kw kw A N/O N/C kg (lb.) LP-D090kk q.00 (.67) LP-D0kk q.00 (.67) LP-D80kk q.70 (.8) LP-D50kk q.750 (3.89) LP-D30kk q.850 (.) Weight Accessories (to be ordered separately) Auxiliary contact blocks and add-on modules, see pages to 9. c Clip-on mounting on 35 mm ( DIN rail AM-DP or screw mounting. adc Coil Selection Uc (Volts) DC U 0.8 to. Uc JD BD CD ED ND SD FD GD MD UD RD U 0.7 to.5 Uc JW BW CW EW SW FW MW Other voltages from to 0 V, see pages 57 to 60. q Includes mechanical interlock (type LA9Dkk978) without electrical contacts. Installer to complete wiring for electrically interlocking contactor operating coils by utilizing a N.C. auxiliary contact integrated in the contactor or optional LADN or LA8DN type auxiliary contact block Square D All Rights Reserved 7/98
29 Control Circuit: DC Horsepower ratings for North American applications Selection Reversing Contactors for Motor Control 3-pole reversing contactors with Fingersafe terminals for power cabling Includes pre-wired power connections q LP-D090kk LP-D50kk Maximum horsepower ratings -phase 50/60 Hz 3-phase 50/60 Hz Maximum inductive current in AC-3 category 600 V Instantantaneous auxiliary contacts per contactor Contactors supplied with coils Catalog number. Complete with code indicating control circuit voltage a DIN rail or screw mounting c hp hp hp hp hp hp A N/O N/C kg (lb.) LP-D090kk q.00 (.67) LP-D0kk q.00 (.67) LP-D80kk q.70 (.8) LP-D50kk q.750 (3.89) LP-D30kk q.850 (.) Weight Accessories (to be ordered separately) Auxiliary contact blocks and add-on modules, see pages to 9. c Clip-on mounting on 35 mm ( DIN rail AM-DP or screw mounting. adc Coil Selection Uc (Volts) DC U 0.8 to. Uc JD BD CD ED ND SD FD GD MD UD RD U 0.7 to.5 Uc JW BW CW EW SW FW MW Other voltages from to 0 V, see pages 57 to 60. q Includes mechanical interlock (type LA9Dkk978) without electrical contacts. Installer to complete wiring for electrically interlocking contactor operating coils by utilizing a N/C auxiliary contact integrated in the contactor or optional LADN or LA8DN type auxiliary contact block. 7/ Square D All Rights Reserved 9
30 Selection Reversing Contactors for Motor Control Control Circuit: DC Kilowatt ratings for international applications 3-pole reversing contactors for ring tongue terminals or bus bar power connections Includes pre-wired power connections Standard power ratings of 3-phase motors 50/60 Hz in category AC-3 0 V 30 V 380 V 00 V 5 V 0 V 500 V 660 V 690 V c Clip-on mounting on 35 mm ( DIN rail AM-DP or screw mounting. Rated operational current in AC-3 0 V up to Instantantaneous auxiliary contacts per contactor Contactors supplied with coils Catalog number. Complete with code indicating control circuit voltage a DIN rail or screw mounting c kw kw kw kw kw kw A N/O N/C kg (lb.) LP-D0906kk q.00 (.67) LP-D06kk q.00 (.67) LP-D806kk q.70 (.8) LP-D506kk q.750 (3.89) LP-D306kk q.850 (.) 3-pole reversing contactors for connection with slip-on connectors Power connections to be made by the customer For contactors LC-D09 and LC-D only, replace the last digit 6 in the above catalog numbers, with a 9. Example: LC-D0906kk becomes LC-D0909kk. These contactors include slip-on connectors: UL recognized E686 NLDX x 6.35 mm (0.5 in.) on the power poles and x 6.35 mm (0.5 in.) on the coil terminals. Accessories (to be ordered separately) Auxiliary contact blocks and add-on modules, see pages to 9. a DC Coil Selection Uc (Volts) DC U 0.8 to. Uc JD BD CD ED ND SD FD GD MD UD RD U 0.7 to.5 Uc JW BW CW EW SW FW MW Other voltages from to 0 V, see pages 57 to 60. q Includes mechanical interlock (type LA9Dkk978) without electrical contacts. Installer to complete wiring for electrically interlocking contactor operating coils by utilizing a N/C auxiliary contact integrated in the contactor or optional LADN or LA8DN type auxiliary contact block. Weight Square D All Rights Reserved 7/98
31 Control Circuit: DC Horsepower ratings for North American applications Selection Reversing Contactors for Motor Control 3-pole reversing contactors for ring tongue terminals or bus bar power connections Includes pre-wired power connections Maximum horsepower ratings -phase 50/60 Hz 3-phase 50/60 Hz Maximum inductive current in AC-3 category 600 V Instantantaneous auxiliary contacts per contactor Contactors supplied with coils Catalog number. Complete with code indicating control circuit voltage a DIN rail or screw mounting c hp hp hp hp hp hp A N/O N/C kg (lb.) LP-D0906kk q.00 (.67) LP-D06kk q.00 (.67) LP-D806kk q.70 (.8) LP-D506kk q.750 (3.89) LP-D306kk q.850 (.) 3-pole reversing contactors for connection with slip-on connectors Power connections to be made by the customer For contactors LC-D09 and LC-D only, replace the last digit 6 in the above catalog numbers, with a 9. Example: LC-D0906kk becomes LC-D0909kk. These contactors include slip-on connectors: UL recognized E686 NLDX x 6.35 mm (0.5 in.) on the power poles and x 6.35 mm (0.5 in.) on the coil terminals. Accessories (to be ordered separately) Weight Auxiliary contact blocks and add-on modules, see pages to 9. c Clip-on mounting on 35 mm ( DIN rail AM-DP or screw mounting. a DC Coil Selection Uc (Volts) DC U 0.8 to. Uc JD BD CD ED ND SD FD GD MD UD RD U 0.7 to.5 Uc JW BW CW EW SW FW MW Other voltages from to 0 V, see pages 57 to 60. q Includes mechanical interlock (type LA9Dkk978) without electrical contacts. Installer to complete wiring for electrically interlocking contactor operating coils by utilizing a N/C auxiliary contact integrated in the contactor or optional LADN or LA8DN type auxiliary contact block. 7/ Square D All Rights Reserved 3
32 Selection Changeover Contactors for Resistive Loads Control Circuit: DC -pole changeover contactors with Fingersafe terminals for power cabling Includes pre-wired power connections Utilization category AC- Non inductive loads Maximum rated operational current (θ < 55 C) Instantaneous auxiliary contacts per contactor Contactors supplied with coils. Catalog number. Complete with code indicating control circuit voltage a c DIN rail or screw mounting Weight LC-D00kk A N/O N/C kg (lb.) 5 LC-D00kk q (.) 0 LC-D500kk q.00 (.) 60 LC-D000kk q.00 (5.33) 80 LC-D6500kk q 3.00 (7.) 5 LC-D8000kk q 3.00 (7.) 00 LC-D500kk f 7.50 (6.)???? lbs -pole changeover contactor pairs, for ring tongue terminals or bus bar connections Includes pre-wired power connections 5 LC-D006kk q (.) LP-D6500kk 0 LC-D5006kk q.00 (.) 60 LC-D0006kk q.00 (5.33) 80 LC-D65006kk q 3.00 (7.) 5 LC-D80006kk q 3.00 (7.) 00 LC-D5006kk f 6.50 (6.)???? lbs -pole changeover contactor pairs for connection with slip-on connectors Power connections to be made by the customer For contactors LC-D09 and LC-D only, replace the last digit 6 in the above catalog numbers, with a 9. Example: LC-D0906kk becomes LC-D0909kk. These contactors include slip-on connectors: UL recognized E686 NLDX x 6.35 mm (0.5 in.) on the power poles and x 6.35 mm (0.5 in.) on the coil terminals. Accessories (to be ordered separately) Auxiliary contact blocks and add-on modules, see pages to 9. c LC-D and D5: clip-on mounting on 35 mm ( DIN rail AM-DP or screw mounting. LC-D0 to D80: clip-on mounting on 35 mm ( DIN rail AM-DE or 75 mm ( DIN rail AM-DL or screw mounting. LC-D5: clip-on mounting on x 35 mm ( DIN rails AM-DP or screw mounting. adc Coil Selection Uc (Volts) DC U 0.8 to. Uc JD BD CD ED ND SD FD GD MD UD RD U 0.7 to.5 Uc JW BW CW EW SW FW MW Other voltages from to 0 V, see pages 57 to 60. q Includes mechanical interlock (type LA9Dkk978) without electrical contacts. Installer to complete wiring for electrically interlocking contactor operating coils by utilizing a N/C auxiliary contact integrated in the contactor or optional LADN or LA8DN type auxiliary contact block Square D All Rights Reserved 7/98
33 Selection Changeover Contactors for Resistive Loads Control circuit: DC -pole changeover contactor pairs with Fingersafe terminals for power cabling Includes pre-wired power connections Utilization category AC- Non inductive loads Maximum rated operational current (θ < 55 C) Instantaneous auxiliary contacts per contactor Contactors supplied with coils Catalog number. Complete with code indicating control circuit voltage a c DIN rail or screw mounting Weight LC-D00kk A N/O N/C kg (lb.) 5 LP-D00kk q.00 (.67) 0 LC-D500kk q.750 (3.89) -pole changeover contactor pairs for ring tongue terminals or bus bar power connections 5 LC-D006kk q.00 (.67) 0 LC-D5006kk q.750 (3.89) -pole changeover contactor pairs for connection with slip-on connectors Power connections to be made by the customer LP-D6500kk For contactors LC-D09 and LC-D only, replace the last digit 6 in the above catalog numbers, with a 9. Example: LC-D0906kk becomes LC-D0909kk. These contactors include slip-on connectors: E686 NLDX x 6.35 mm on the power poles and x 6.35 mm on the coil terminals. Accessories (to be ordered separately) Auxiliary contact blocks and add-on modules, see pages to 9. c LC-D and D5: clip-on mounting on 35 mm ( DIN rail AM-DP or screw mounting. LC-D0 to D80: clip-on mounting on 35 mm ( DIN rail AM-DE or 75 mm ( DIN rail AM-DL or screw mounting. LC-D5: clip-on mounting on x 35 mm ( DIN rails AM-DP or screw mounting. adc Coil Selection Uc (Volts) DC U 0.8 to. Uc JD BD CD ED ND SD FD GD MD UD RD U 0.7 to.5 Uc JW BW CW EW SW FW MW Other voltages from to 0 V, see pages 57 to 60. q Includes mechanical interlock (type LA9Dkk978) without electrical contacts. Installer to complete wiring for electrically interlocking contactor operating coils by utilizing a N/C auxiliary contact integrated in the contactor or optional LADN or LA8DN type auxiliary contact block. 7/ Square D All Rights Reserved 33
34 Combinations Reversing contactors types LC-D and LP-D Components for assembling reversing contactors and changeover contactor, for customer assembly Contactors Mechanical interlocks Sets of power connections Reversers using identical contactors horizontally mounted type Without electrical interlocking With integral electrical interlocking ( x N.C. contacts) 3-pole reversing contactors L L L3 A A 3 or -pole changeover contactor pairs A A A A /L /L /L3 U V W 3 5 L L L3 8 7 N /L /L /L3 N A A N LC-D09 LC-D LC-D8 LC-D5 LC-D3 LC-D38 LP-D09 LP-D LP-D8 LP-D5 LP-D3 LA9-D09978 LA9-D090 LA9-D69 LA9-D869 LA9-D569 LA9-D369 LA9-D70 (P) LA9-D570 (P) LC-D0 LC-D50 LC-D65 LA9-D50978 LA9-D00 LA9-D6569 LA9-D6570 (P) LP-D0 LP-D50 LP-D65 LC-D80 LC-D95 LA9-D8069 LA9-D8070 (P) LP-D80 LA9-D80978 LA9-D800 LA9-D8069 LA9-D8070 (P LC-D5 LC-D50 Not available LA9-D50 LA9-D569 LA9-D57 (3P) LA9-D570 (P) (D5 only) Square D All Rights Reserved 7/98
35 Selection Components for assembling reversing contactors and changeover contactors, horizontally mounted, for customer assembly Component parts (including mechanical interlock with integrated electrical contacts) With identical contactors c Set of power connections Catalog number Weight kg (lb.) For assembly of 3-pole reversing contactors for motor control Mechanical interlock kit Catalog number Weight kg (lb.) LC/LP-D09/D LA9-D (0.033) LA9-D (0.3) LC/LP-D8 LA9-D (0.066) LA9-D (0.3) LC/LP-D5 LA9-D (0.066) LA9-D (0.3) LC/LP-D3/D38 LA9-D (0.088) LA9-D (0.3) LC/LP-D0/D50 LA9-D (0.638) LA9-D (0.37) LC/LP-D65 LC-D80/D95 LA9-D (.078) LA9-D (0.37) LP-D80 LA9-D (.078) LA9-D (0.37) LC-D5/D50 LA9-D (3.90) LA9-D (0.638) For assembly of 3-pole changeover contactors LC-D5/D50 LA9-D (.) LA9-D (0.638) For assembly of -pole changeover contactors (3-phase + neutral distribution system) LC/LP-D00 LA9-D (0.0) LA9-D (0.3) LC/LP-D500 LA9-D (0.0) LA9-D (0.3) LC/LP-D000/D6500 LA9-D (0.330) LA9-D (0.37) LC-D8000 LA9-D (0.66) LA9-D (0.37) LP-D8000 LA9-D (0.66) LA9-D (0.37) LC-D500 LA9-D (.77) LA9-D (0.638) Component parts (including mechanical interlock without electrical contacts) For assembly of 3-pole reversing contactors for motor control LC/LP-D090/D0 LA9-D (0.033) LA9-D (0.066) LC/LP-D80 LA9-D (0.066) LA9-D (0.066) LC/LP-D50 LA9-D (0.066) LA9-D (0.066) LC/LP-D30/D380 LA9-D (0.088) LA9-D (0.066) LC/LP-D0/D50 LC/LP-D65 LA9-D (0.638) LA9-D (0.3) LC-D80/D95 LA9-D (.078) LA9-D (0.3) LP-D80 LA9-D (.078) LA9-D (0.396) For assembly of -pole changeover contactors (3-phase + neutral distribution system) a LC/LP-D00 LA9-D (0.0) LA9-D (0.066) LC/LP-D500 LA9-D (0.0) LA9-D (0.066) LC/LP-D000/D6500 LA9-D (0.330) LA9-D (0.3) LC-D8000 LA9-D (0.66) LA9-D (0.3) LP-D8000 LA9-D (0.66) LA9-D (0.396) c To order the contactors: see pages to 3. a Order contact blocks LA8-DNk or LA-DNk to obtain electrical interlockingof operating coils. See pages and 3. 7/ Square D All Rights Reserved 35
36 Characteristics Auxiliary contact blocks without dust and damp protected contacts Type LA-D LA-D LA3-D LA8-D c Environment Conforming to standards Meets the essential requirements of the LV & EMC directives IEC 337-, 97-, 97-5, 97-5-, NF C VDE 0660, BS 79 Approvals E686 CCN NLDX LR336 Class 3 0 ASE, UL, CSA, DEMKO, NEMKO, SEMKO, FI Protective treatment Conforming to IEC 68 TH Degree of protection Conforming to VDE 006 Protection against direct finger contact IPX Storage - 60 to + 80 C (-76 to +76 F) Ambient air temperature around the device For operation at 80 to 0% of nominal control voltage - 5 to + 55 C (+3 to +3 F) Permissible for operation at nominal control voltage - 0 to + 70 C (-0 to +58 F) Maximum operating altitude Without derating 3000m (8900 ft.) or conductors AWG 8 to Cabling Stranded or solid cable with or without cable end mm to.5 Tightening torque Phillips head No. or Ø 6 mm (3/6 in.) screwdriver 0.8 Nkm (7 lb. in.) Instantaneous and time delay contacts Number of contacts or Rated operational voltage (Ue) Up to V 660 Conforming to IEC 97- V 690 Rated insulation voltage (Ui) Conforming to VDE 00 group C V 750 Conforming to CSA V 600 Rated thermal current (Ith) For ambient temperature 0 C (0 F) A 0 Frequency of operational current Hz 5 to 00 U min V 7 Minimum switching capacity I min ma 5 Short-circuit protection To IEC and VDE gg fuse. A 0 Rated making capacity Conforming to IEC I rms A AC: 0; DC: 50 s A 00 Short time rating Permissible for 500 ms A 0 00 ms A 0 Insulation resistance MΩ > 0 Non-overlap time Guaranteed between N.C. and N.O. contacts ms.5 (on opening and closing) Overlap time Guaranteed between N.C. and N.O. on LA-DC ms.5 Time delay (LA-D and LA3-D contact blocks) Accuracy only valid for setting range indicated on the front face c For use on contactors LC-D and LP-D only. Ambient air temperature for operation - 0 to + 70 C (-0 to +58 F) - 0 to + 70 C (-0 to +58 F) Repeat accuracy ± % ± % Drift up to 0.5 million operating cycles + 5 % + 5 % Drift depending on ambient air temperature 0.5 % per C 0.5 % per F 0.5 % per C 0.5 % per F Mechanical durability In millions of operating cycles Operational power of contacts See page Square D All Rights Reserved 7/98
37 Characteristics Auxiliary contact blocks without dust and damp protected contacts Operational power of contacts (conforming to IEC 97-5-) AC supply, categories AC- and AC-5 Electrical durability (up to 3600 operating cycles/hour) on an inductive load such as the coil of an electromagnet: making power (cos ϕ 0.7) = 0 times the power broken (cos ϕ 0.). V 8 0/7 0/ / million operating cycles VA million operating cycles VA million operating cycles VA Occasional making capacity VA a Breaking limit of contacts for: maximum of 50 operating cycles at 0 s intervals (breaking power = making power x cos ϕ 0.7). Electrical durability of contacts: - for million operating cycles (a). - for 3 million operating cycles (b). - for 0 million operating cycles (c). Thermal limit b c V DC supply, category DC-3 Electrical durability (up to 00 operating cycles/hour) on an inductive load such as the coil of an electromagnet, without economy resistor, the time constant increasing with the power. V million operating cycles W million operating cycles W million operating cycles W Occasional making capacity W Electrical durability of contacts: - for million operating cycles (a). - for 3 million operating cycles (b). - for 0 million operating cycles (c). 3 Breaking limit of contacts for: maximum of 0 operating cycles at 0 s intervals and with current passing for 0.5 s per operating cycle. Thermal limit a b c V 7/ Square D All Rights Reserved 37
38 Characteristics Auxiliary contact blocks with dust and damp protected contacts Type LA-DX LA-DZ LA-DY Environment Conforming to standards Meets the essential requirements of the LV & EMC directives IEC 97-5-, VDE 0660 Approvals E686 CCN NLDX LR336 Class 3 0 UL, CSA Protective treatment Conforming to IEC 68 TH TH TH Degree of protection Conforming to VDE 006 Protection against direct finger contact IPX Ambient air temperature around the device Storage Operation - 5 to + 70 C (-3 to +58 F) - 5 to + 70 C (-3 to +58 F) - 5 to + 70 C (-3 to +58 F) - 5 to + 70 C (-3 to +58 F) - 5 to + 70 C (-3 to +58 F) - 5 to + 70 C (-3 to +58 F) or conductors AWG 8 to 8 to 8 to Cabling Stranded or solid cable with or without cable end mm to.5 to.5 to.5 Tightening torque Phillips head No. or Ø 6 mm (3/6 in.) flat blade screwdriver 0.8 Nkm (7 lb. in.) 0.8 Nkm (7 lb. in.) 0.8 Nkm (7 lb. in.) Number of contacts Characteristics of dust and damp protected contacts ( non dust & damp protected) Rated operational voltage (Ue) Up to V Rated insulation voltage (Ui) Conforming to IEC V Maximum operational current (Ie) ma U min V Minimum switching capacity I min ma 0.3 Insulation resistance MΩ > 0 > 0 > 0 Mechanical durability In millions of operating cycles Materials and technology used for dust and damp protected contacts Characteristics of non dust and damp protected contacts Silver Single break Silver Single break Rated operational voltage (Ue) Up to V 690 Conforming to IEC V 690 Rated insulation voltage (Ui) Conforming to UL/CSA V 600 Rated thermal current (Ith) For ambient temperature 0 C A 0 Frequency of operational current Hz 5 to 00 U min V 7 Minimum switching capacity I min ma 5 Short-circuit protection Conforming to IEC gg fuse A 0 Rated making capacity Conforming to IEC I rms A c: 0; a: 50 s A 00 Short time rating Permissible for 500 ms A 0 00 ms A 0 Insulation resistance MΩ > 0 Operational power of contacts See page 37 Gold Single break with crossed bars Square D All Rights Reserved 7/98
39 Characteristics Interface Modules Environment Conforming to standards Meets the essential requirements of the LV & EMC directives IEC 55-5 File 6353 CCN NKCR LR336 Class 3 0 Protective treatment Conforming to IEC 68 TH Degree of protection Conforming to VDE 006 Protection against direct finger contact IPX Ambient air Storage - 0 to + 80 C (-0 to +76 F) temperature Operation at 80 to 0% of nominal control voltage - 5 to + 55 C (-3 to +3 F) around the device Permissible for operation at Uc - 5 to + 70 C (-3 to +58 F) Other characteristics Type LA-DFBQ LA-DFB LA-DFE LA-DLB LA-DLE LA-DWB With relay With relay With relay With relay + override Solid state Rated insulation voltage Conforming to IEC 97- V Rated operational voltage Conforming to IEC 97- V Indication of input state By integral LED which illuminates when the contactor coil is energized Input signals Control voltage (E-E) V DC DC 8 DC DC 8 DC DC Permissible variation V 7 to 30 7 to to 60 7 to to 60 5 to 30 Current consumption at 0 C ma U V <. <. <.8 <. <.8 <. State 0 guaranteed for I ma < < <.3 < <.3 < State guaranteed for U V Built-in protections Against reversed polarity By diode Of the input By diode Electrical durability at 0/0 V In millions of operating cycles Maximum immunity to micro-breaks ms Power dissipated At 0 C W For use with contactor Total operating time at Uc (of the contactor) Cabling Tightening torque With to 50 V DC coil LP-D09 to D3 to 50 V coil AC LC-D09 to D50 00 to 50 V coil AC 380 to 5 V coil AC LC-D09 to D50 Operating times depend on the type of contactor electromagnet and its control mode. The closing time C is measured from the moment the coil supply is switched on to initial contact of the main poles. The opening time O is measured from the moment the coil supply is switched off to the moment the main poles separate. With LA-DF, DL or conductors Stranded or solid cable with or without cable end Phillips head No. or Ø 6 mm (3/6 in.) flat blade screwdriver LC-D09 to D8 LC-D5 to D38 LC-D0 to D65 LC-D80 and D95 LP-D09 to D8 8.5 for 5V 5 for V LC-D09 to D38 LC-D0 to D5 LP-D5 and D3 C ms 0 to 30 3 to 3 8 to 3 8 to 3 8 to to 7 O ms 6 to 7 to 3 0 to 8 to 3 8 to 6 0 to 6 AWG 8 to mm to Nkm (7 lb. in.) 7/ Square D All Rights Reserved 39
40 Characteristics Electronic serial timer modules Type LA-DT (On-delay) LA-DR (Off-delay) for LC-D Environment Conforming to standards Meets the essential requirements of the LV & EMC directives IEC 55-5 Approvals E686 CCN NLDX LR336 Class 3 0 UL, CSA Protective treatment Conforming to IEC 68 TH Degree of protection Conforming to VDE 006 Protection against direct finger contact IPX Storage - 0 to + 80 C (-0 to +76 F) Ambient air temperature around the device Operation at 80 to 0% of nominal control voltage - 5 to + 55 C (-3 to +3 F) Permissible for operation at Uc - 5 to + 70 C (-3 to +58 F) Rated insulation voltage (Ui) To IEC 97- and VDE 00 (group C) V 50 Cabling or conductors AWG 8 to Stranded or solid cable with or without cable end mm to.5 Tightening torque Phillips n or Ø 6 mm (3/6 in.) flat blade screwdriver 0.8 Nkm (7 lb.-in.) Control circuit characteristics On input By varistor By varistor Built-in protection Suppression of contactor By varistor By bidirectional peak limiting diode Rated control circuit voltage (Uc) V to 50 AC or DC to 50 DC Permissible variation 0.8 to. Uc 0.8 to. Uc Type of control By mechanical contact only By mechanical contact only connecting cable < 0 m (30 ft.) Time delay characteristics Timing ranges s 0. to ;.5 to 30; 5 to to ;.5 to 30; 5 to 500 Repeat accuracy 0 to 0 C ± 3 % (0 ms minimum) ± 3 % (0 ms minimum) Reset time During the time delay period ms 50 5 After the time delay period ms 50 During the time delay period ms 0 0 Immunity to micro-breaks After the time delay period ms Minimum control pulse duration ms 0 Indication of time delay By LED Illuminates during time delay period Illuminates during time delay period Switching characteristics (solid state type) Maximum power dissipated W 3.5 Leakage current ma < 5 < 5 Residual voltage V Short-circuit protection 3 kv; 0.5 joule 3 kv; 0.5 joule Electrical durability In millions of operating cycles Operating diagrams LA-DT on-delay electronic timers LA-DR off-delay electronic timers U supply (A-A) Time delay output Contactor coil ms t U supply (A-A) Control (A-B) Time delay output 0 0 t Red LED Contactor coil Red LED Square D All Rights Reserved 7/98
41 Characteristics Control modules, coil suppressor modules and mechanical latch block Environment Approvals Meets the essential requirements of the LV & EMC directives File 6353 CCN NKCR LR336 Class 3 0 Protective treatment Conforming to IEC 68 TH Degree of protection Conforming to VDE 006 Protection against direct finger contact IPX Storage - 0 to + 80 C (-0 to +76 F) Ambient air temperature around the device Operation at 80 to 0% of nominal control voltage - 5 to + 55 C (-3 to +3 F) Permissible for operation at Uc - 5 to + 70 C (-3 to +58 F) Automatic - Manual - Stop modules LA-DM Recommendation The Auto-Man selector switch must only be operated with the Start-Stop ( O - I ) switch in position O Rated insulation voltage Conforming to IEC 97- V 50 Rated operational voltage Conforming to IEC 97- V 50 Protection Against electric shocks kv Built-in protection Contactor coil suppression By varistor Indication By integral LED Illuminates when the contactor coil is energized Electrical durability In operating cycles Coil suppressor modules Type LA-DA LA-DB LA-DC LA-DE Type of protection Rated control circuit voltage (Uc) Maximum peak voltage V RC circuit to 5 AC 300% nominal voltage Bidirectional peak limiting diode to 7 AC or DC 00% nominal voltage Diode to 50 DC 00% nominal voltage /8 V Hz 00 50/7 V Hz 00 Natural RC frequency 0/0 V Hz /5 V Hz 50 Mechanical latch block characteristics Type LA6-DK0 LA6-DK0 LC-D09 to D65 LC-D80 to D50 For mounting on contactor LP-D09 to D65 LP-D80 Approval UL, CSA UL, CSA Rated insulation voltage Conforming to IEC 97 V Rated control circuit voltage 50/60 Hz AC and DC V to 5 to 5 AC VA 5 5 Power required For unlatching DC W Maximum operating rate In operating cycles per hour On-load factor 0 % 0 % Mechanical durability at Uc In millions of operating cycles Varistor to 50 AC or DC 00% nominal voltage Unlatching can be manually operated or electrically controlled (pulsed). The LA6-DK does not include a coil clearing contact. The latch coil and the LC-D operating coil must not be energized or maintained simultaneously. Duration of control signals 00 ms. 7/ Square D All Rights Reserved
42 Auxiliary Contact Blocks 0-7V AC-DC 50/60Hz E E LA-DN0, DN0 LA6-DK 0 LA6 DK0 LA8-DN LA-DN LA8-DN LC-LP LA-DN, DC LA-DT, DS LA3-DR LA-DX, DY, DZ 998 Square D All Rights Reserved 7/98
43 Selection - Auxiliary Contact Blocks For type LCk-D and LPk-D: Auxiliary contact blocks Instantaneous auxiliary contact blocks For use in normal operating environments Number of contacts per block Clip-on mounting on contactor Auxiliary Contacts Catalog number Weight Front mount Side mount c f N/O N/C kg (lbs.) LC-D5 to D95 LA-DN0 a 0.00 (0.0) LP-D5 to D80 LA-DN0 a 0.00 (0.0) LA-DN (0.066) LC-D09 to D50 LP-D09 to D80 LA-DN (0.066) LA-DN (0.066) LC-D09 to D50 LA8-DN q (0.066) LP-D09 to D3 LA8-DN0 q (0.066) LA-DN (0.) 3 LA-DN (0.) LC-D09 to D50 LA-DN (0.) LP-D09 to D80 LA-DN (0.) 3 LA-DN (0.) LA-DC a (0.) With terminal referencing conforming to standard EN 500 LC-D090 to D380 LA-DNM (0.066) LP-D090 to to D30 LC/LP-D0900 to D300 LA-DNP (0.066) LC-D500/D5000 LC-D0 to D95 LA-DNG (0.066) LP-D0 to D80 LA-DNM (0.) LC-D090 to D380 LP-D090 to D30 3 LA-DN3M (0.) 3 LA-DN3M (0.) LA-DNP (0.) LC/LP-D0900 to D300 LC-D500/D LA-DN3P (0.) 3 LA-DN3P (0.) LC-D0 to D (0.) LA-DNG LP-D0 to D (0.) Instantaneous auxiliary contact blocks with dust and damp protected contacts For use in harsh industrial environments LC-D09 to D50 to 50 V LA-DX (0.088) LP-D09 to D80 5 to V LA-DY0 f 0.00 (0.088) LC-D09 to D50 to 50 V LA-DZ (0.) LP-D09 to D80 to 50 V LA-DZ (0.3) a Maximum number of blocks per contactor: block from D5 to D38, blocks from D0 to D95. q Set of shims required for mounting on LC-D0 to D95, to be ordered separately, see page 5. f Supplied with grounding terminal connections. c Dust-tight auxiliary contacts (IP5) NEMA rating. 7/ Square D All Rights Reserved 3
44 Seriplex Module, Time Delay Blocks and Mechanical Latch Blocks 0-7V AC-DC 50/60Hz E E LA-DN0, DN0 LA6-DK 0 LA6 DK0 LA-DN0, DN0 LA8-DN LA-DN LA8-DN LC-LP LA-DN, DC LA-DT, DS LA-SPX LA3-DR LA-DX, DY, DZ 998 Square D All Rights Reserved 7/98
45 Selection Seriplex module, time delay auxiliary contact blocks and mechanical latch blocks Seriplex Seriplex block per contactor Clip-on front mounting Operates coils up to Approvals File E96 CCN NRAQ LR5353 Class 5 0 Contactor adaptor t module LC-D09 to D80 LP-D09 to D80 Time delay auxiliary contact blocks 77 VAC VDC LA-SPX 0.07 (0.60) Number of contacts block per contactor Time delay Catalog number c Weight Clip-on front mounting Type Setting range kg (lb.) 0. to 3 s a LA-DT (0.3) N.O. + N.C. Mechanical latch blocks LC-D09 to D50 LP-D09 to D80 On-delay Off-delay 0. to 30 s LA-DT (0.3) 0 to 80 s LA-DT (0.3) to 30 s q LA-DS (0.3) 0. to 3 s a LA3-DR (0.3) 0. to 30 s LA3-DR (0.3) 0 to 80 s LA3-DR (0.3) Unlatching control Manual or electric block per contactor Clip-on front mounting LC-D09 to D65 LP-D09 to D65 LC-D80 to D50 LP-D80 Catalog number to be completed f Weight kg (lb.) LA6-DK0k (0.5) LA6-DK0k (0.98) c Sealing cover, LA9-D90 to be ordered separately, see page 5. a With extended scale from 0. to 0.6 s. q With switching time of 0 ms ± 5 ms between opening of the N.C. and closing of the N.O. contact. f Standard control circuit voltages (for other voltages, please consult our local representatives or agents). Volts 50/60 Hz, a 3/36 /8 60/7 00 0/7 0/0 56/77 380/5 Code B C E EN K F M U Q t For more information refer to Seriplex catalog 833OCT960 7/ Square D All Rights Reserved 5
46 Selection - Electronic Timers and Interface Modules LA-DT LA-DR LA-DF LA-DL LA-DW LA-DM LC-D LA-DT LA-DF LA-DL LA-DM 6 LP-D 998 Square D All Rights Reserved 7/98
47 Selection Electronic Timers and Interface Modules Electronic serial timer modules c The solid state modules delay the energizing and de-energizing of the contactor coil. a Operational voltage to energize contactor coil Time delay Catalog number Weight AC DC to 50 V 00 to 50 V to 50 V kg (lb.) On-delay type D09 to D38 D0 to D50 D09 to D3 Off-delay type D09 to D8 D5 to D50 0. to s LA-DT0U 0.00 (0.088).5 to 30 s LA-DTU 0.00 (0.088) 5 to 500 s LA-DTU 0.00 (0.088) 0. to s LA-DR0U (0.).5 to 30 s LA-DRU (0.) 5 to 500 s LA-DRU (0.) Interface modules c Operational voltage to energize contactor coil Input signal voltage DC Catalog number Weight AC DC to 50 V 00 to 50 V 380 to 5 V to 50 V E-E kg (lb.) Relay interface D09 to D50 V LA-DFBQ (0.) V LA-DFB (0.)!??! D09 to D50 D09 to D3 8 V LA-DFE (0.)!??! Relay interface with manual override switch (output forced ON ) V LA-DLB 0.05 (0.099) D09 to D50 D09 to D3 8 V LA-DLE 0.05 (0.099) Solid state interface D09 to D38 D0 to D5 V LA-DWB 0.05 (0.099) Auto-Man-Stop control modules c For local override operation tests with -position Auto-Man switch and O-I switch Operational voltage to energize contactor coil Catalog number Weight AC DC to 00 V 00 to 50 V to 00 V 00 to 50 V kg (lb.) D09 to D50 D09 to D3 LA-DMK 0.00 (0.088) D09 to D50 D09 to D3 LA-DMU 0.00 (0.088) c Mounted directly on terminals A and A screws. a For V, operation, the contactor must be fitted with a V coil (code Z5 for 50 Hz, Z6 for 60 Hz or ZD for DC). 7/ Square D All Rights Reserved 7
48 Coil Suppressor Modules LA-Di LA-Di LC-D LA-Di LA-Di, Di3 LP-D Square D All Rights Reserved 7/98
49 Selection Coil suppressor modules RC circuits (resistor-capacitor) c Mounted at top For use with contactor a Reference Weight of contactor on coil terminals A Rating Type and A AC DC V V kg Clip-on mounting and to 8 LA-DAE 0.0 (0.06) connection without tools to the contactor 50 to 7 LA-DAG 0.0 (0.06) D09 to D38 coil terminals. Mounting of an input module is still possible 0 to 0 LA-DAU 0.0 (0.06) Screw connection to the contactor coil terminals. Mounting ot the input module not possible. D09 to D50 Varistors (peak limiting) q Clip-on mounting and electrical connection. Mounting of an input module is still possible Screw mounting Diodes f Clip-on mounting and electrical connection. Mounting of an input module is still possible Screw mounting D09 to D38 D09 to D38 D0 to D5 D0 to D5 Bidirectional peak limiting diode t Clip-on mounting and electrical connection. Mounting of an input module is still possible Screw connection to the contactor coil terminals. Mounting ot the input module not possible. to 8 LA-DAE 0.08 (0.039) 50 to 7 LA-DAG 0.08 (0.039) 0 to 0 LA-DAU 0.08 (0.039) 380 to 5 LA-DAN 0.08 (0.039) to 8 to 8 LA-DEE 0.0 (0.06) 50 to 7 50 to 7 LA-DEG 0.0 (0.06) 0 to 50 0 to 50 LA-DEU 0.0 (0.06) to 8 to 8 LA-DEE 0.08 (0.039) 50 to 7 50 to 7 LA-DEG 0.08 (0.039) 0 to 50 0 to 50 LA-DEU 0.08 (0.039) to 8 LA-DEE 0.08 (0.039) 50 to 7 LA-DEG 0.08 (0.039) 0 to 50 LA-DEU 0.08 (0.039) to 8 LA-DE3E 0.08 (0.039) 50 to 7 LA-DE3G 0.08 (0.039) 0 to 50 LA-DE3U 0.08 (0.039) D09 to D3 to 50 LA-DCU 0.0 (0.06) D09 to D3 to 50 LA-DCU 0.08 (0.039) D0 to D80 to 50 LA-DC3U 0.08 (0.039) D09 to D38 D09 to D3 LA-DBB 0.0 (0.06) 7 LA-DBS 0.0 (0.06) LA-DBB 0.0 (0.06) 7 LA-DBS 0.0 (0.06) D09 to D95 LA-DBB 0.08 (0.039) 7 LA-DBS 0.08 (0.039) D09 to D3 LA-DBB 0.08 (0.039) 7 LA-DBS 0.08 (0.039) D0 to D80 LA-DB3B 0.08 (0.039) 7 LA-DB3S 0.08 (0.039) c Effective protection for circuits highly sensitive to high frequency interference. For use only in cases where the voltage is virtually sinusoidal, i.e. - 5% total harmonic distortion. Voltage limited to 3 Uc max and oscillating frequency limited to 00 Hz max. Slight increase in drop-out time (. to times the normal time). a For satisfactory protection, a suppressor module must be fitted across the coil of each contactor. q Protection provided by limiting the transient voltage to Uc max. Maximum reduction of transient voltage peaks. Slight increase in drop-out time (. to.5 times the normal time). f No overvoltage or oscillating frequency. Increase in drop-out time (6 to 0 times the normal time). Polarised component. t Protection provided by limiting the transient voltage to Uc max. Maximum reduction of transient voltage peaks. 7/ Square D All Rights Reserved 9
50 Selection - Contactors and Reversing Contactors LA9-D60 LA9-D860 LA9-D096 LA9-D8096 LA9-D360 LA9-D560 LA9-D6 LA9-D8096 LA9-D0963 LA9-D56 LA9-D6 LA9-D80963 LA9-D8067 LA9-D6567 LA9-D563 LA9-D63 LC-D3, D38 LP-D3 LC-D8 LP-D8 LC-D80, D95 LP-D80 LC-D0, D50, D65 LP-D0, D50, D65 LC-D5 LP-D5 LA9-D9 LC-D09, D LP-D09, D LA9-D93 50 LA9-D9 998 Square D All Rights Reserved 7/98
51 Types LCk-D and LPk-D Accessories for main pole and control connections Selection - Contactors and Reversing Contactors LA9-D860 LA9-D550k LA9-D560k Description Connectors for larger cable sizes IP0 Finger-safe terminals for stranded or solid cable Connectors for ring tongue terminals or bus bar Links for parallel connection of For use on contactors Sold in lots of Catalog number Weight LC LP kg (lb.) -pole 0 mm D09, D D09, D LA9-D (0.066) 3-pole 5 mm D500 D3, D38 D3 LA9-D (0.088) D8 D8 LA9-D (0.077) -pole 5 mm D5 D5 LA9-D (0.) 3-pole 0 mm D5, D50 D5, D50 LA9-D (0.88) -pole 0 mm D5 D5 LA9-D (.606) 3-pole D5, D50 D5, D50 LA9-D (0.506) -pole D5 D5 LA9-D (0.70) poles 3 poles (Wye-delta shorting strap) D09, D D09, D 0 LA9-D6 0.0 (0.06) D5 D5 0 LA9-D (0.3) D0 to D65 D0 to D65 LA9-D (0.06) D80, D95 D80 LA9-D (0.3) D09, D D09, D 0 LA9-D (0.006) D80, D95 D80 LA9-D (0.76) D09, D D09, D LA9-D (0.053) D5 D5 LA9-D (0.037) poles D0 to D65 D0 to D65 LA9-D (0.5) D80, D95 D80 LA9-D (0.) Staggered coil connection D0 to D80 0 LA9-D (0.03) Control circuit take-off from main pole Spreaders for increasing the pole pitch to 5 mm D500, D5000 D0 to D65 0 LA9-D (0.0) D80 0 LA9-D (0.0) D500. D GV7-AC (0.00) LA9-D6 LA9-D8096 LA9-D6567 7/ Square D All Rights Reserved 5
52 Selection - Contactors and Reversing Contactors Contactors and reversing contactors types LCk-D and LPk-D Sets of contacts For contactor Type Catalog number Weight kg (lb.) LC-D500 LA5-D (0.8) 3-pole LC-D5000 LA5-D (0.8) -pole LC-D500 LA5-D (0.66) Arc chamber LC-D500 LA5-D (0.79) 3-pole LC-D5000 LA5-D (0.79) -pole LC-D500 LA5-D (.0) Accessories for protection and marking LA9-D9 Description For use on Sold in lots of Catalog Weight number Contactors Add-on blocks AC DC kg (lb.) Miniature fuse holder type 5 x 0 with A-50 V fuse D09 to D50 D09 to D80 LA9-D (0.055) Legend holder 8 x mm snap-in Legend holder 8 x 7 mm snap-in D09 to D50 D09 to D80 LA-D ( contacts) LA-D, LA3-D, LA6-DK LA-DN ( contacts) LA-D Bag of 300 labels (blank, self-adhesive) 7 x mm D09 to D50 D09 to D80 ( contacts) LA-D, LA3-D, LA6-DK 00 LA9-D (0.00) 00 LA9-D (0.00) LA9-D (0.00) Bag of 00 labels (blank, self-adhesive) 7 x 6 mm LA-DN LA9-D (0.00) ( contacts) Sealing cover (for time-delay LA, LA3-D LA9-D (0.0) auxiliary contact block) Mounting accessories 35mm DIN rail (7.5mm deep x mm long) D09 to D38 AM-DP (.0) 35mm DIN rail (5mm deep x mm long) D09 to D38 AM-ED00.30 (.880) 75mm DIN rail (5mm deep x mm long) D0 to D95 AM-DL (6.600) Adaptor for mounting on ' rail D09 to D38 D09 to D3 LA9-D (0.055) Mounting plates for fixing on ' D09 to D8 D09 to D8 0 DX-AP (0.3) rails (0 mm fixing centers) D5 and D38 D5 and D38 0 DX-AP (0.80) Mounting plate Replacement F5, F50 by D5.D50 LA9-D (0.79) Set of shims for attacing side-mounting blocks LA8-DN on LC-D0 to D95 contactors LA9-D (0.0) Square D All Rights Reserved 7/98
53 AC coils For contactors LC-D09, D, D8, D500 D-Line Contactors, Overload Relays and Accessories Selection LX-Dkk Control circuit voltage Uc Average resistance at 0 C ± 0% Inductance of closed circuit Catalog number c Average resistance at 0 C ± 0 % Inductance of closed circuit Catalog number c V Ω H Ω H kg (lb.) Specifications Average consumption at 0 C: - inrush (cos ϕ = 0.75) 50 Hz: 60 VA, 60 Hz: 70 VA. - sealed (cos ϕ = 0.3) 50 Hz: 7 VA, 60 Hz: 7.5 VA. Operating range (θ 55 C): 0.8 to. Uc. 50 Hz 60 Hz a LX-DZ LX-DZ (0.5) LX-DB LX-DB (0.5) LX-DC (0.5) LX-DD (0.5) LX-DE LX-DE (0.5) LX-DF LX-DF (0.5) LX-DG (0.5) LX-DG (0.5) LX-DL (0.5) LX-DM (0.5) 0/ LX-DM (0.5) LX-DP (0.5) LX-DU LX-DU (0.5) LX-DW (0.5) LX-DW (0.5) LX-DQ (0.5) 380/ LX-DQ (0.5) LX-DV (0.5) LX-DN LX-DN (0.5) LX-DR LX-DR (0.5) LX-DT (0.5) LX-DS (0.5) LX-DS (0.5) LX-DX (0.5) LX-DY (0.5) Specifications Average consumption at 0 C: - inrush (cos ϕ = 0.75) 50/60 Hz: 70 VA to 50 Hz. - sealed (cos ϕ = 0.3) 50/60 Hz: 8 VA to 50 Hz. Operating range (θ 55 C): 0.85 to. Uc. 50/60 Hz a LX-DZ (0.5) LX-DB (0.5) LX-DD (0.5) 8 5 LX-DE (0.5) LX-DF (0.5) 5 LX-DFE (0.5) LX-DG (0.5) 0/30 q 539 LX-DM (0.5) LX-DP (0.5) 30/0 f 65 5 LX-DU (0.5) 380/ LX-DQ (0.5) LX-DV (0.5) LX-DN (0.5) 0 79 LX-DR (0.5) Weight c The last digits of the reference represent the voltage code. a Voltage for special coils in contactors with LA-DT or LA-DR electronic serial timer modules, with V supply. q This coil can be used on 0 V at 60 Hz. f This coil can be used on 30/0 V at 50 Hz and at 0 V only at 60 Hz. 7/ Square D All Rights Reserved 53
54 D-Line Contactors, Overload Relays and Accessories Selection AC coils For contactors LC-D5 (except LC-D500), D3, D38 LX-Dkk Control circuit voltage Uc Average resistance at 0 C ± 0% Inductance of closed circuit Catalog number c Average resistance at 0 C ± 0 % Inductance of closed circuit Catalog number c V Ω H Ω H kg (lb.) Specifications Average consumption at 0 C: - inrush (cos ϕ = 0.75) 50 Hz: 90 VA, 60 Hz: 00 VA. - sealed (cos ϕ = 0.3) 50 Hz: 7.5 VA, 60 Hz: 8.5 VA. Operating range (θ 55 C): 0.8 to. Uc. 50 Hz 60 Hz a LX-DZ LX-DZ (0.5) LX-DB LX-DB (0.5) LX-DC (0.5) LX-DD (0.5) LX-DE LX-DE (0.5) LX-DF LX-DF (0.5) LX-DG (0.5) LX-DG (0.5) 08 7 LX-DL (0.5) LX-DM (0.5) 0/30 3 LX-DM (0.5) LX-DP (0.5) LX-DU LX-DU (0.5) LX-DW (0.5) LX-DW (0.5) LX-DQ (0.5) 380/ LX-DQ (0.5) LX-DV (0.5) LX-DN (0.5) LX-DR LX-DR (0.5) LX-DT (0.5) LX-DS (0.5) LX-DS (0.5) LX-DX (0.5) LX-DY (0.5) Specifications Average consumption at 0 C: - inrush (cos ϕ = 0.75) 50/60 Hz: 00 VA to 50 Hz. - sealed (cos ϕ = 0.3) 50/60 Hz: 8.5 VA to 50 Hz. Operating range (θ 55 C): 0.85 to. Uc. 50/60 Hz a LX-DZ (0.87) LX-DB (0.87) LX-DD (0.87) LX-DE (0.87) LX-DF (0.87) 5 LX-DFE (0.87) LX-DG (0.87) 0/30 q LX-DM (0.87) LX-DP (0.87) 30/0 f 5 3 LX-DU (0.87) 380/ LX-DQ (0.87) LX-DV (0.87) LX-DN (0.87) LX-DR (0.87) Weight c The last digits of the reference represent the voltage code. a Voltage for special coils in contactors with LA-DT or LA-DR electronic serial timer modules, with V supply. q This coil can be used on 0 V at 60 Hz. f This coil can be used on 30/0 V at 50 Hz and at 0 V only at 60 Hz Square D All Rights Reserved 7/98
55 AC coils For contactors LC-D0, D50, D65, D80, D95 D-Line Contactors, Overload Relays and Accessories Selection LX-D6kk Control circuit voltage Uc Average resistance at 0 C ± 0% Inductance of closed circuit Catalog number c Average resistance at 0 C ± 0 % Inductance of closed circuit Catalog number c V Ω H Ω H kg (lb.) Specifications Average consumption at 0 C: - inrush (cos ϕ = 0.75) 50 Hz: 00 VA, 60 Hz: 0 VA. - sealed (cos ϕ = 0.3) 50 Hz: 0 VA, 60 Hz: VA. Operating range (θ 55 C): 0.85 to. Uc. 50 Hz 60 Hz LX-D6B LX-D6B (0.66) LX-D6C (0.66). 0.7 LX-D6D (0.66) LX-D6E LX-D6E (0.66) LX-D6F5. LX-D6F (0.66) LX-D6G (0.66) 7. LX-D6G (0.66) LX-D6L (0.66) LX-D6M (0.66) 0/ LX-D6M (0.66) LX-D6P (0.66) LX-D6U LX-D6U (0.66) LX-D6W (0.66) LX-D6W (0.66) LX-D6Q (0.66) 380/00 38 LX-D6Q (0.66) 00 5 LX-D6V (0.66) LX-D6N (0.66) LX-D6R LX-D6R (0.66) LX-D6T (0.66) LX-D6S (0.66) LX-D6S (0.66) LX-D6X (0.66) LX-D6Y (0.66) Specifications Average consumption at 0 C: - inrush (cos ϕ = 0.75) 50 /60 Hz: 5 VA to 50 Hz. - sealed (cos ϕ = 0.3) 50/60 Hz: 6 VA to 50 Hz. Operating range (θ 55 C): 0.85 to. Uc. 50/60 Hz LX-D6B (0.66) LX-D6D (0.66) LX-D6E (0.66) LX-D6F (0.66) 5 LX-D6FE (0.66) 0 3 LX-D6G (0.66) 0/30 a LX-D6M (0.66) LX-D6P (0.66) 30/0 q LX-D6U (0.66) 380/00 f 30 0 LX-D6Q (0.66) LX-D6V (0.66) LX-D6N (0.66) LX-D6R (0.66) Weight c The last digits of the reference represent the voltage code. a For use on 30 V 50 Hz, apply a multiplying factor of 0.6 to the mechanical durability of the contactor, see pages 6 and 7. This coil can be used on 0 V at 60 Hz. q This coil can be used on 30/0 V at 50 Hz and at 0 V only at 60 Hz. f For use on 00 V 50 Hz, apply a multiplying factor of 0.6 to the mechanical durability of the contactor, see pages 6 and 7. 7/ Square D All Rights Reserved 55
56 D-Line Contactors, Overload Relays and Accessories Selection AC coils For contactors LC-D5 LX-D8kk Control circuit voltage Uc Average resistance at 0 C ± 0% Inductance of closed circuit Catalog number c Average resistance at 0 C ± 0 % Inductance of closed circuit Catalog number c V Ω H Ω H kg (lb.) Specifications Average consumption at 0 C: - inrush (cos ϕ = 0.75) -50 or 60 Hz: 300 VA. - sealed (cos ϕ = 0.3) -50 or 60 Hz: VA. Operating range (θ 55 C): 0.85 to. Uc. 50 Hz 60 Hz LX-D8B LX-D8B (0.66) LX-D8C (0.66) LX-D8D (0.66) LX-D8E LX-D8E (0.66) LX-D8F LX-D8F (0.66) LX-D8FE (0.66) LX-D8G (0.66) LX-D8FC (0.66) LX-D8L (0.66) LX-D8M LX-D8M (0.66) LX-D8P (0.66) LX-D8U LX-D8U (0.66) LX-D8W (0.66) LX-D8Q LX-D8Q (0.66) LX-D8V (0.66) LX-D8N (0.66) LX-D8R LX-D8R (0.66) LX-D8T (0.66) LX-D8S (0.66) Weight For contactors LC-D5, D50 Specifications Average consumption at 0 C: - inrush: cos ϕ = VA. - sealed: cos ϕ = VA. Operating range (θ 55 C): 0.8 to.5 Uc. Coils with built-in surge suppression device, class B 50/60 Hz LX-D8B (0.66) LX-D8C (0.66) LX-D8D (0.66) LX-D8E (0.66) LX-D8F (0.66) LX-D8FE (0.66) LX-D8G (0.66) LX-D8FC (0.66) LX-D8L (0.66) LX-D8M (0.66) LX-D8P (0.66) LX-D8U (0.66) LX-D8UE (0.66) LX-D8Q (0.66) LX-D8V (0.66) LX-D8N (0.66) LX-D8R (0.66) LX-D8T (0.66) LX-D8S (0.66) c The last digits of the reference represent the voltage code Square D All Rights Reserved 7/98
57 DC coils For contactors LP-D09, D, D8 D-Line Contactors, Overload Relays and Accessories Selection LX-Dkk Control circuit voltage Uc Average resistance at 0 C ± 0% Inductance of closed circuit Catalog number c Weight V Ω H kg (lb.) Specifications Average consumption: 9 W. Operating range (θ 55 C): 0.8 to. Uc LX-DJD 0.75 (0.385) a 5..6 LX-DZD 0.75 (0.385) 7 3. LX-DBD 0.75 (0.385) LX-DCD 0.75 (0.385) LX-DED 0.75 (0.385) 60 9 LX-DND 0.75 (0.385) LX-DSD 0.75 (0.385) LX-DFD 0.75 (0.385) LX-DGD 0.75 (0.385) LX-DMD 0.75 (0.385) LX-DUD 0.75 (0.385) LX-DRD 0.75 (0.385) For contactors LP-D5, D3 Specifications Average consumption: W. Operating range (θ 55 C): 0.8 to. Uc LX-DJD 0.65 a 36.. LX-DZD LX-DBD LX-DCD LX-DED 0.65 LX-Dkk LX-DND LX-DSD LX-DFD LX-DGD LX-DMD LX-DUD LX-DRD 0.65 c The last digits of the reference represent the voltage code. a Voltage for special coils in contactors with LA-DT or LA-DR electronic serial timer modules, with V supply. 7/ Square D All Rights Reserved 57
58 D-Line Contactors, Overload Relays and Accessories Selection DC coils For contactors LP-D0, D50, D65 LX-D6kk Control circuit voltage Uc Average resistance at 0 C ± 0% Inductance of closed circuit Catalog number c Weight V Ω H kg (lb.) Specifications Average consumption: W. Operating range: 0.85 to. Uc LX-D6JD 0.5 (0.93) LX-D6BD 0.5 (0.93) LX-D6CD 0.5 (0.93) LX-D6ED 0.5 (0.93) LX-D6ND 0.5 (0.93) LX-D6SD 0.5 (0.93) LX-D6FD 0.5 (0.93) LX-D6GD 0.5 (0.93) 0 55 LX-D6MD 0.5 (0.93) LX-D6UD 0.5 (0.93) LX-D6RD 0.5 (0.93) For contactors LP-D80 Specifications Average consumption: W. Operating range: 0.85 to. Uc LX-D7JD (.96) 7.89 LX-D7BD (.96) LX-D7CD (.96) LX-D7ED (.96) LX-D7kk LX-D7ND (.96) LX-D7SD (.96) LX-D7FD (.96) LX-D7GD (.96) LX-D7MD (.96) LX-D7UD (.96) LX-D7RD (.96) c The last digits of the reference represent the voltage code Square D All Rights Reserved 7/98
59 DC coils For contactors LC-D5, D50 Control circuit voltage Uc D-Line Contactors, Overload Relays and Accessories Selection Average resistance at 0 C ± 0 % Inductance of closed circuit Catalog number c Weight V Ω H kg (lb.) Specifications Average consumption: 6 W. Operating range: 0.7 to. Uc. Coils with built-in surge suppression, class B LX-D8BD (0.66) LX-D8ED (0.66) LX-D8ND (0.66) LX-D8SD (0.66) LX-D8FD (0.66) LX-D8GD (0.66) LX-D8MD (0.66) LX-D8UD (0.66) LX-D8RD (0.66) LX-D8kk c The last digits of the reference represent the voltage code. 7/ Square D All Rights Reserved 59
60 D-Line Contactors, Overload Relays and Accessories Selection Wide range DC coils (for greater voltage operating range) For contactors LP-D09, D, D8 LX-Dkk Control circuit voltage Uc Average resistance at 0 C ± 0 % Inductance of closed circuit Catalog number c Weight V Ω H kg (lb.) Specifications Average consumption: W. Operating range: 0.7 to.5 Uc. Coils with TH treatment as standard LX-DJW f 0.75 (0.385) LX-DBW f 0.75 (0.385) LX-DCW f 0.75 (0.385) LX-DEW f 0.75 (0.385) LX-DSW f 0.75 (0.385) LX-DFW f 0.75 (0.385) LX-DMW f 0.75 (0.385) For contactors LP-D5, D3 LX-Dkk Specifications Average consumption: 3 W. Operating range: 0.7 to.5 Uc. Coils with TH treatment as standard LX-DJW f 0.65 (0.583) 9..7 LX-DBW f 0.65 (0.583) LX-DCW f 0.65 (0.583) LX-DEW f 0.65 (0.583) LX-DSW f 0.65 (0.583) LX-DFW f 0.65 (0.583) LX-DMW f 0.65 (0.583) For contactors LP-D0, D50, D65 LX-D6kk Specifications Average consumption: W. Operating range: 0.75 to. Uc. Coils with TH treatment as standard LX-D6JW f 0.5 (0.93) 30.9 LX-D6BW f 0.5 (0.93) LX-D6CW f 0.5 (0.93) LX-D6EW f 0.5 (0.93) 7 5. LX-D6SW f 0.5 (0.93) LX-D6FW f 0.5 (0.93) LX-D6MW f 0.5 (0.93) For contactors LP-D80 Specifications Average consumption: 3 W. Operating range: 0.75 to. Uc. Coils with TH treatment as standard LX-D7JW f (.96) LX-D7BW f (.96) LX-D7CW f (.96) LX-D7EW f (.96) LX-D7SW f (.96) LX-D7FW f (.96) 0 9 LX-D7MW f (.96) c The last digits of the reference represent the voltage code. f Wide range coils cannot be used on contactors utilizing both front and side mounted auxiliary contact blocks Square D All Rights Reserved 7/98
61 D-Line Contactors, Overload Relays and Accessories Dimensions Contactors, types LC-D LC-D09, D LC-D8, LC-D500 Dimensions shown in millimeters (mm X.039 = inches) LC-D50, D50, D50 LC-D3 = = 0 Minimum electrical clearance c c(la) c(la6-dk0) c3(la,la3) 7,5 (LA8) LA 77(Di) 90(Di) 5,5 (LA8) 97(3)(DF,DT) 05(3) (DM,DR,DW,DL) 0 Minimum electrical clearance c c(la) c(la6-dk0) c3(la,la3) 8,5 (LA8) LA 87(Di) 00(Di) 56,5 (LA8) 07(3)(DF,DT) (DM,DR,DW,DL) 5(3) LC- c c c c c3 a LC- c c c c c3 a D09, D D50, D50, D D8, D D () With or contacts. () With or contacts; contact = 0 (D5) and 5 (D3) (LA-DN0 or DN0) () + mm with sealing cover. () + mm with sealing cover. (3) With or without combined use of a coil suppressor module (LA-DA, DB, DE). (3) With or without combined use of a coil suppressor module (LA-DA, DB, DE). LC-D0, D50, D65 LC-D80, D Minimum electrical clearance 7 LA 35(Di, Di3) (DF,DT) 50(DM,DR,DW,DL) Minimum electrical clearance 7 LA 35(Di, Di3) (DF,DT) 50(DM,DR,DW,DL) () 6()(LA) 57(LA6-DK0) 65()(LA,LA3),5 (LA8) (3),5 (LA8) 5() 53()(LA) 65(LA6-DK0) 73()(LA,LA3),5 (LA8) (3),5 (LA8) () With or contacts; contact = 39 (LA-DN0 or DN0) () With or contacts; contact = 7 (LA-DN0 or DN0) () + mm with sealing cover. () + mm with sealing cover. (3) 75: 3-pole, 85: -pole. (3) 85: 3-pole, 96: -pole. () 5: LC-Dkk008. () 0: LC-Dkk008. LC-D5, D50 68()(LA,LA3) LA 58 LA8 7(Di, Di3) 85(DF,DT) 88(DM,DR,DW,DL) c 50()(LA) 55(LA6-DK0) a LC- c a D500, D D D5006, D D () With or contacts. () + mm with sealing cover. 7/ Square D All Rights Reserved 6
62 D-Line Contactors, Overload Relays and Accessories Dimensions Contactors, types LC-D LP-D09, D, D8 Dimensions shown in millimeters (mm X.039 = inches) LP-D5, D3 = = Minimum electrical clearance 7 LA 77(Di) 90(Di) 97(3)(DF,DT) 05(3)(DM,DL) Minimum electrical clearance 8 LA 87(Di) 00(Di) 07(3)(DF,DT) 5(3)(DM,DL) 0 c c(la) c(la6-dk0) c3(la,la3),5 (LA8) 5,5 (LA8) 0 c c (LA) c(la6-dk0) c3(la,la3),5 (LA8) 56,5 (LA8) LP- c c c c c3 a LP- c c c c c3 a D09, D D D D () With or contacts () With or contacts; contact: 57 (D5), 6 (D3) (LA-DN0 or DN0) () + mm with sealing cover () + mm with sealing cover (3) With or without combined use of a coil suppressor module (LA-DB, DC, DE). (3) With or without combined use of a coil suppressor module (LA-DB, DC, DE). LP-D0, D50, D65 Minimum electrical clearance LA-Di3 LP-D80 Minimum electrical clearance LA-Di () 0()LA) 3(LA6-DK0) ()(LA,LA3) (3) 8() 0()(LA) (LA6-DK0) 9()(LA,LA3) (3) () With or contacts; contact: 96 (LA-DN0 or DN0) () With or contacts; contact: 0 (LA-DN0 or DN0) () + mm with sealing cover () + mm with sealing cover (3) 75: 3-pole, 85: -pole (3) 85: 3-pole, 96: -pole () 8: LP-Dkk008 () 96: LP-Dkk Square D All Rights Reserved 7/98
63 D-Line Contactors, Overload Relays and Accessories Mounting Contactors, types LC-D and LP-D LC-D09 to D38, LP-D09 to D3 On mounting rail AM-DP00 or AM-DE00 (width 35mm) Dimensions shown in millimeters (mm X.039 = inches) LC-D0 to D95, LP-D0 to D80 On mounting rail AM-DL00 or DL0 (width 75 mm) For LC on mounting rail AM-EDkkk or AM-DE00 (width 35 mm) = b = 7 = c c LC- D09 D D8 D5 D3 D38 LC- D0 D50 D65 D80 D95 b c (AM-DL00) c (AM-DP00) c (AM-DL0) 3 3 c (AM-DE00) c (AM-EDkkk or DE00) 3 3 LP- D09 D D8 D5 D3 LP- D0 D50 D65 D80 c (AM-DP00) c (AM-DL00) c (AM-DE00) c (AM-DL0) LC-D5, D50 On mounting rail AM-DP00 or AM-DE00 (width 35mm) = 00 = 58 = c LC- D500 D500 6 D5000 D c (AM-DP00 or DR00) c (AM-DEkkk or EDkkk) LC-D09 to D38, LP-D09 to D3 On mounting rail DZ5-MB and clip-on mounting plate LA9-D973 D09 to D8 LA9-D973 D5, D3 LA9-D973 LC-D0 to D95, LP-D0 to D80 On mounting rails DZ5-MB on 0 mm centers DZ5-ME5 c = 35 = = = 0 0 c 5 0 LC- D09 D D8 D5 D3 D38 LC- D0 D50 D65 D80 D95 c c 5 5 LP- D09 D D8 D5 D3 LP- D0 D50 D65 D80 c c / Square D All Rights Reserved 63
64 D-Line Contactors, Overload Relays and Accessories Mounting Contactors, types LC-D and LP-D LC-D09 to D38, LP-D09 to D3 On mounting rails DZ5-MB on 0 mm centres DZ5-ME5 Dimensions shown in millimeters (mm X.039 = inches) On mounting rails DZ5-MB on 60 mm centres DZ5-ME8 () c 5 G c 7 LC- D09 D D8 D5 D3 D38 LC- D09 D D8 D5 D3 D38 a c c G LP- D09 D D8 D5 D3 LP- D09 D D8 D5 D3 a c c G or 50 0 or 50 () DX-AP5 (Lk-D09 to D8), DX-AP6 (Lk-D5 and D3) LC-D09 to D38, LP-D09 to D3 On pre-slotted mounting plate AM-PA, PB, PC AF-EA a LC-D0 to D95, LP-D0 to D80 On pre-slotted mounting plate AM-PA, PB, PC 50 0 c LC- D09 D D8 D5 D3 D38 LC- D0 D50 D65 D80 D95 c c 5 5 G LP- D09 D D8 D5 D3 LP- D0 D50 D65 D80 c c G or 50 0 or 50 LC-D09 to D38, LP-D09 to D8 Panel mounted with #8 screws G xm xø.5mm LP-D5 and D3 Panel mounted with #8 screws c LC-D0 to D95, LP-D0 to D80 Panel mounted with / screws 0 AF-EA6 3xØ6.5mm c = 50 = = G = = G = = 00/0 = c = 0 = LC- D09 D D8 D5 D3 D38 LC- D0 D50 D65 D80 D95 c c 5 5 G LP- D09 D D8 D5 D3 LP- D0 D50 D65 D80 c c G LC-D5, D50 Panel mounted with / screws 30 = 58 c = = G = LC- D500 D5006 D5000 D50006 c G (3-poles) 96/0 96/0 96/0 96/0 G (-poles) 30/ 30/ Square D All Rights Reserved 7/98
65 D-Line Contactors, Overload Relays and Accessories Dimensions, mounting Reversing contactors types LC-D and LP-D LC-D09 to D38 x LC-D09 to D38 Panel mounted with #8 screws b e Dimensions shown in millimeters (mm X.039 = inches) xø.5mm 50/60 = LP-D09 to D3 x LP-D09 to D3 Panel mounted with #8 screws b e xø.5mm 50/60 = = = c e = G = a c e = G = a LC- or x LC- a b c e (3 P) e ( P) G LP- or x LP- a b c e (3 P) e ( P) G D09, D D09, D D D D D D3, D D c, e and e including cabling c, e and e including cabling LC-D0 to D65 x LC-D0 to D65 Panel mounted with / screws b e 6xØ6.5mm = G = 00/0 8 x LP-D0 to D65 Panel mounted with / screws b e 6xØ6.5mm = G = /0 8 c e = 0 G 0 = c e = 0 G 0 = a a LC- or x LC- (3-pole) a b c e G G x LP- (3-pole) a b c e G G D0, D50, D D0, D50, D LC- or x LC- (-pole) a b c e G G x LP- (-pole) a b c e G G D0, D D0, D c, e and e including cabling c, e and e including cabling LC-D80 and D95 x LC-D80 and D95 Panel mounted with / screws b e 6xØ6.5mm = G = 00/0 8 x LP-D80 Panel mounted with / screws b e 6xØ6.5mm = G = 3 00/0 8 3 c e = 0 G 0 = a c e = 0 G 0 = a LC- or x LC- (3-pole) a b c e G G x LP- (3-pole) a b c e G G D80, D D LC- or x LC- (-pole) a b c e G G x LP- (-pole) a b c e G G D D c, e and e including cabling c, e and e including cabling c Dimensions with auxiliary contact blocks and add-on modules, see pages 6 and 6. 7/ Square D All Rights Reserved 65
66 D-Line Contactors, Overload Relays and Accessories Dimensions, mounting Reversing contactors types LC-D and LP-D LC-D5 and D50 x LC-D5 and D50 Panel mounted with / screws Dimensions shown in millimeters (mm X.039 = inches) 58 e 30 = c e = G = a = LC- or x LC- (3-pole) a c e e G D5, D /56 LC- or x LC- (-pole) a c e e G D /3 c, e and e including cabling Square D All Rights Reserved 7/98
67 D-Line Contactors, Overload Relays and Accessories Schemes Contactors, types LC-D and LP-D 3-pole contactors LC-D0900 to D300 LC-D500 and D5000 LC-D090 to D380 LP-D090 to D30 LC-D090 to D380 LP-D090 to D30 LC and LP- D0 to D95 -pole contactors LC and LP- D00 to D8000 LC-D500 LC and LP- D008 to D5008 LC and LP- D0008 to D80008 Front-mounting contact blocks Instantaneous auxiliary contacts N.O. LA-DN0 c N.C. LA-DN0 c N.O. + N.C. LA-DN N.O. LA-DN0 N.C. LA-DN0 N.O. + N.C. LA-DN N.O. + 3 N.C. LA-DN3 N.O. LA-DN0 N.C. LA-DN0 N.O. + N.C. including N.O. + N.C. make before break LA-DC 3 N.O. + N.C. LA-DN3 Front-mounting contact blocks Instantaneous auxiliary contacts conforming to standard EN 500 N.O. + N.C. LA-DNP N.O. + N.C. LA-DNG N.O. + N.C. LA-DNM N.O. + 3 N.C. LA-DN3P 3 N.O. + N.C. LA-DN3P N.O. + N.C. LA-DNP N.O. + N.C. LA-DNG N.O. + 3 N.C. LA-DN3M 3 N.O. + N.C. LA-DN3M N.O. + N.C. LA-DNM 3/NO /NC 3 3/NC 3/NO 3 3/NC /NC 5 53/NO 6 63/NO /NC 3 3/NC /NC 5 53/NO /NC 3 33/NO 3/NO 5 53/NO /NC 3 3/NC 3/NO 5 53/NO 3/NO /NC 3 3/NC 3/NO /NC 3 33/NO 3/NO /NC 3 3/NC /NC 3/NO /NC 3 33/NO 3/NC 5 5/NC 6 6/NC 7 7/NC 8 8/NC 5 53/NO 6 6/NC 76 75/NC 88 87/NO 5 53/NO 6 6/NC 7 73/NO 8 83/NO 5 5/NC 6 6/NC 5 53/NO 6 6/NC 7 7/NC 8 83/NO 5 53/NO 6 6/NC 7 7/NC 8 8/NC 5 53/NO 6 63/NO 7 73/NO 8 83/NO 3/NO (93) (9) /NC (9) (9) 5 53/NO 6 6/NC 5 53/NO 6 63/NO A T/ T/ T3/6 T/8 A R R A R R A A A /L 3/L 5/L3 7/L R R3 3 R 3 R3 A A T/ /L T/ 3/L T3/6 5/L3 A A T/ /L T/ 3/L T3/6 5/L3 3/NO A A T/ /L T/ 3/L T3/6 5/L3 /NC A A T/ /L T/ 3/L T3/6 5/L3 3/NO /NC c Single pole auxiliary contact blocks mounted on right-hand side of contactor. 7/ Square D All Rights Reserved 67
68 D-Line Contactors, Overload Relays and Accessories Schemes Contactors, types LC-D and LP-D Front-mounting contact blocks Dust and damp protected instantaneous auxiliary contacts N.O. (-50 V) LA-DX0 N.O. (5- V) LA-DY0 Includes grounding terminal points N.O. protected (-50 V) N.O. standard LA-DZ0 N.O. protected (-50 V) + N.O. + N.C. normal LA-DZ3 Front-mounting contact blocks Time delay auxiliary contacts On-delay N.O. + N.C. LA-DTk Off-delay N.O. + N.C. LA3-DRk On-delay N.C. with N.O. break before make LA-DSk Mechanical latch blocks LA6-DK0 and LA6-DK0 Side-mounting contact blocks Instantaneous auxiliary contacts N.O. + N.C. LA8-DN N.O. LA8-DN0 5 53/NO (83) (8) 6 6/NC (7) (7) 5 53/NO (83) (8) 6 63/NO (73) (7) E A A E 56 55/NC 68 67/NO 58 57/NO 66 65/NC 56 55/NC 68 67/NO 5 53/NO 6 63/NO 5 53/NO 6 63/NO 5 53/NO 6 63/NO 7 73/NO 8 83/NO 5 53/NO 6 6/NC 7 73/NO 8 83/NO Electronic serial timer modules On-delay LA-DTkU Off-delay LA-DRkU LA-DMk Auto-Man-Stop control modules A A 0 c a K t A A A A c B 0 t K A A A A () B K c a A A c Programmable controller Interface modules Relay interface LA-DFk Relay interface LA-DFBQ Relay interface Relay interface with manual override switch LA-DLk Solid state LA-DWBk A c E + A E A c A c E + E A c A c E + E A c A c E + E A c K A A K A A K A A K A Square D All Rights Reserved 7/98
69 D-Line Contactors, Overload Relays and Accessories Schemes Contactors, types LC-D and LP-D Reversing contactors, horizontally mounted LC-D09 to D38, LP-D09 to D3 Reversing contactors, horizontally mounted LC-D0 to D95 Changeover contactors, horizontally mounted LC-D, LP-D Reversing contactors, horizontally mounted LC-D5 and D50 U V W L L L3 N A 6 6 A A A /L 3 /L 6 5 /L3 8 7 N /L 3 /L 6 5 /L3 8 7 N A A A A 0 0 L L L3 U V W U V W A A /NC /NC A A A A /NO /NC /NO /NC A A L L L3 L L L3 Electrical interlocking of contactors with mechanical interlock with integrated electrical contacts LA9-Dkkk0 Electrical interlocking of contactors with mechanical interlock without integrated electrical contacts LA9-Dkkk78 A A 0 A A KM KM KM KM KM Coil 0 0 KM Coil 0 KM A A KM KM A A A A A A KM A A 7/ Square D All Rights Reserved 69
70 D-Line Contactors, Overload Relays and Accessories Scheme, setting-up, 3-pole bimetallic overload relays LR or LR3-D Scheme LR-D LR3-D 3 5 Reset { Auto Man Setting-up the special functions of LR-D and LR3-D thermal overload relays Setting the relay Manual-Automatic selection ,5 TEST 8 A LR D 3 STOP M RESET A U T O 5 RESET A U T O RESET A U T O NO NC k Lift the transparent cover to gain access to the settings and controls. k Adjustment is achieved by turning dial which is graduated directly in amperes. k The setting can be locked by sealing 3 of the cover. Stop function 5 Test function 6 Manual reset Automatic reset k After having lifted the transparent cover, the type of reset operation can be selected by turning the blue RESET selector : - turn to the left for manual reset, - push and turn to the right for automatic reset. The selector is then held in the automatic position and is released by turning the selector to the left (return to manual operation). k With the cover folded down, the selector is locked. k Manual resetting of the relay is achieved by pressing the blue RESET button. STOP ET A U T O RESET A U T O TEST Stop Locking Test Trip indicator k The Stop function is obtained by pressing the red STOP button 5. k Pressing the STOP button: -actuates the N.C. contact, - does not affect the N.O. contact. k The STOP button can be locked by fitting a U clip (ref. LA7-D90). With the cover folded down, the device is locked. k The Test function is obtained by pressing the red TEST button 6 with a screwdriver. k Operation of the TEST button simulates tripping of the relay and: - actuates both N.O. and N.C. contacts, - actuates the trip indicator Square D All Rights Reserved 7/98
71 D-Line Contactors, Overload Relays and Accessories Characteristics 3-pole bi-metallic overload relays LR or LR3-D Application LR and LR3-D 3-pole bimetallic overload relays are designed to protect a.c. circuits and motors against overloads, phase failure, long starting times and prolonged stalling of the motor. Environment Conforming to standards Meets the essential requirements of the LV & EMC directives IEC 97-, IEC 97-, NF C , VDE 0660, BS 9 Approvals E6353 CCN NKCR LR336 Class 3 03 LR D, D, D3: ASE, CSA, UL, DEMKO, NEMKO, FI, SEMKO, Sichere Trennung, PTB. LR-D: UL, CSA Degree of protection Conforming to VDE 006 Protection against direct finger contact Protective treatment Standard version TH Ambient air temperature around Storage - 60 to + 70 C (-76 to +58 F) the device Normal operation without derating (IEC 97-) - 30 to + 55 C (- to +3 F) Operational limits (with derating) - 0 to + 70 C (-0 to +58 F) Direct mounting Beneath the contactor LC-D, LP-D Operating positions without derating In relation to normal vertical mounting plane Auxiliary contact characteristics Rated thermal current A 5 Maximum sealed consumption for operating coils of controlled contactors (Occasional operating cycles of contact 95-96) AC supply V VA V DC supply W Short-circuit protection By circuit breaker Select in accordance with NEC and local codes By fuses Maximum 00% of motor FLA Cabling Min./max. c.s.a. Flexible cable without cable end or conductors mm /.5 Flexible cable with cable end or conductors mm /.5 Solid cable without cable end or conductors mm /.5 Tightening torque. Nkm (0 lb.-in.) Minimum x 8 AWG Maximum x AWG 7/ Square D All Rights Reserved 7
72 D-Line Contactors, Overload Relays and Accessories Characteristics 3-pole bi-metallic overload relays LR or LR3-D Electrical characteristics of power circuit Type LR-D LR3-D LR-D LR3-D LR-D3 LR3-D3 LR-D Conforming to IEC 97- V Rated insulation voltage (Ui) Conforming to UL, CSA V Rated impulse withstand voltage (Uimp) kv Frequency limits Of the operational current Hz 0 to 00 0 to 00 0 to 00 0 to 00 Tripping class Conforming to UL 508, IEC 97-0 or or or Setting range Depending on model A 0. to 5 3 to 0 7 to 0 80 to 0 Cabling Stranded cable without cable end or conductors Tightening torque Stranded cable with cable end Solid cable without cable end Operating characteristics or conductors or conductors AWG -8 mm.5/0 AWG 8 mm / AWG 8-8 mm /6.85 N m (5 lb.-in.) -8.5/0 8 /6-8.5/0.5 Nkm (5 lb.-in.) 0-0 /35 / /35 9 Nkm (5 lb.-in.) 0- /50 0- / /50 9 Nkm (5 lb.-in.) Reset Manual or automatic Selected by a switch, which can be locked and sealed, on the front face of the relay Indication On front face of relay Relay trip indicator Stop function Test function Tripping curves LR-D Average operating times depending on multiples of the current setting Relay can be locked in Stop position Accessed by pressing the Test button with a screwdriver Time Operating the Stop button: - actuates the N.C. contact, - does not affect the N.O. contact. Operating the Test button allows: - checking of control wiring, - simulation of relay ripping (actuates both N.C. and N.O. contacts). Class 0 Time Class ,8 0, ,8 0, Balanced operation, 3-phase, from cold state. Balanced operation, -phase, from cold state. 3 Balanced operation, 3-phase, after a long period at the set current (hot state) Square D All Rights Reserved 7/98
73 3-pole Solid-state Overload Relays LR9-D Scheme, setting-up Scheme LR9-D KM /L 3/L /T /T 6/T3 96 5/L L L L3 () Test Stop Reset man. % () (3) A M 3 M KM 3 () Tripped N KM A A () () Overload (3) Setting current () Specialized circuit Setting up the special functions of the LR9-D solid state overload relay Setting the relay LR9 D 5369 Ir(A) 7 50 protection électronique moteur ELECTRONIC MOTOR PROTECTION NO NC Lift the transparent cover (7) to gain access tot he various settings and controls. Adjustment is achieved by turning dial () which is graduated directly in amperes. The setting can be locked by sealing cover (7). Stop function (3) Test function () Stop Test Trip indicator The Stop function is obtained by pressing the red STOP button (3). Pressing the STOP button: - actuates the N/C contact, - does not affect the N/O contact. The STOP button can be locked by fitting a U clip (reference LA7-D90). The TEST function is obtained by pressing the red TEST button () with a screwdriver. Operation of the TEST button simulates tripping of the relay and: - actuates both the N/O and N/C contacts, - actuates the trip indicator (5). 7/ Square D All Rights Reserved 73
74 3-pole Solid-state Overload Relays LR9-D Environment Conforming to standards Meets the essential requirements of the LV & EMC directives IEC 97-, 55-8, 55-7 and VDE 0660 Product vertifications E6353 CCN NKCR LR336 Class 3 03 UL 508, CSA -, PTB pending Degree of protection Conforming to VDE 006 IP X Protective treatment Standard version TH Ambient air temperature around the device (conforming to IEC 55-8) Storage C - 0 to +85 C (-0 to +85 F) Normal operation C - 0 to + 55 C (- to +3 F) Maximum operating altitude Without derating 000 m (6500 ft.) Operating positions without derating In relation to normal vertical mounting plane Any position Shock resistance Permissible acceleration conforming to IEC g - ms Vibration resistance Permissible acceleration conforming to IEC g Dialectric strength 50 Hz Conforming to IEC 55-5 kv 6 Impulse withstand voltage Conforming to IEC 55-5 kv 6 Resistance to electrostatic discharges Conforming to IEC 55-5 kv 8 Resistance to radio-frequency conducted disturbances Conforming to IEC 55-5 V/m 0 Resistance to fast transient currents Conforming to IEC 55-5 kv Electromagnetic compatibility Draft EN5008- and, EN5008- Meets requirements Auxiliary contact characteristics Rated thermal current A 5 Maximum sealed consumption for operating coils of controlled contactors (Occasional operating cycles of contact 95-96) AC supply V VA V DC supply W Short-circuit protection By circuit breaker Select in accordance with NEC and local codes By fuses Maximum 00% of motor FLA Cabling Min./max. c.s.a. Flexible cable without cable end or conductors mm /.5 Flexible cable with cable end or conductors mm /.5 Solid cable without cable end or conductors mm /.5 Tightening torque. Nkm (0 lb.-in.) Minimum x 8 AWG Maximum x AWG Square D All Rights Reserved 7/98
75 3-pole Solid-state Overload Relays LR9-D Electrical characteristics of power circuit Type c Not for use with soft start units or variable speed controllers. LR9-D5369, LR9-D5569 Rated insulation voltage (Ui) Conforming to IEC 97- V 000 Rated insulation voltage (Ue) Conforming to VDE 00 gr C V 000 Rated impulse withstand voltage (Uimp) kv 8 Frequency limits Of the operational current Hz 50/60 c Tripping class Conforming to UL 508, IEC 97-0, 0A or 0 Setting range A 90 to 50 Cabling Tightening torque Operating characteristics Using DZFG lug AWG 6 to 3/0 Using LA9F03 terminal AWG 6 to 300 mcm Using DZFG lug Using LA9F03 terminal.5 Nkm (00 lb-in.) Nkm (00 lb-in.) with mm (5/3 in) Hex key Temperature compensation - 0 to + 70 C (- to +58 F) Reset Manual on front face of relay Fault indication On front face of relay Stop function Actuation of the N/C contact without affecting the N/O contact Test function On front face of relay Tripping thresholds Conforming to IEC 97-- A. ± 6% of In Sensitivity to phase failure Conforming to IEC 97-- Tripping in s ± 0% in the event of phase failure Setting (nominal motor current) By setting dial on front face of relay Sealing Yes Tripping curve LR9-D Average operating times depending on multiples of the current setting , / Square D All Rights Reserved 75
76 Selection 3-pole bi-metallic overload relays Class 0 c bi-metallic overload relays LRk-D Thermal overload relays - ambient compensated with manual or automatic reset - relay trip indicator - for AC or DC - with or without single-phase sensitivity LR-D3kk LR-D3kk LR-D33kk Short -circuit protection for North American applications Relay setting range European type fuses maximum rating By circuit breaker By fuses For direct mounting beneath contactor c Standard IEC 97- specifies a tripping time for 7. times the setting current I R : class 0: between and 0 seconds. Select in accordance with NEC and local codes Maximum 00% of motor FLA Catalog number am gg BS88 LC LP With single phase Without single phase A A A A sensitivity sensitivity kg (lb) 0.0 to D09 to D38 D09 to D3 LR-D30 LR3-D (0.363) 0.6 to D09 to D38 D09 to D3 LR-D30 LR3-D (0.363) 0.5 to 0.0 D09 to D38 D09 to D3 LR-D303 LR3-D (0.363) 0.0 to 0.63 D09 to D38 D09 to D3 LR-D30 LR3-D (0.363) 0.63 to D09 to D38 D09 to D3 LR-D305 LR3-D (0.363) to.6 6 D09 to D38 D09 to D3 LR-D306 LR3-D (0.363).6 to D09 to D38 D09 to D3 LR-D307 LR3-D (0.363).5 to D09 to D38 D09 to D3 LR-D308 LR3-D (0.363) to D09 to D38 D09 to D3 LR-D30 LR3-D (0.363) 5.5 to D09 to D38 D09 to D3 LR-D3 LR3-D (0.363) 7 to D09 to D38 D09 to D3 LR-D3 LR3-D (0.363) 9 to D to D38 D to D3 LR-D36 LR3-D (0.363) to D8 to D38 D8 to D3 LR-D3 LR3-D (0.363) 7 to D5 to D38 D5 and D3 LR-D3 LR3-D (0.363) 3 to D5 to D38 D5 and D3 LR-D353 LR3-D (0.70) 30 to D3 and D38 D3 LR-D355 LR3-D (0.70) 7 to D0 to D95 D0 to D80 LR-D33 LR3-D (.) 3 to D0 to D95 D0 to D80 LR-D3353 LR3-D (.) 30 to D0 to D95 D0 to D80 LR-D3355 LR3-D (.) 37 to D50 to D95 D50 to D80 LR-D3357 LR3-D (.) 8 to D50 to D95 D50 to D80 LR-D3359 LR3-D (.) 55 to D65 to D95 D65 and D80 LR-D336 LR3-D (.) 63 to D80 and D95 D80 LR-D3363 LR3-D (.) 80 to D95 LR-D3365 LR3-D (.) 80 to D5 and D50 LR-D365 LR3-D (.98) 95 to D5 and D50 LR-D367 LR3-D (.98) 0 to D50 LR-D369 LR3-D (.98) Thermal overload relays for use on 000 V supplies For relays LR-D30 to LR-D3 only, for an operating voltage of 000 V and only for independent mounting, the reference becomes LR-D33kkA66. Example: LR3-D3 becomes LR-D33A66. Order an LA7-D306 terminal block separately, see pages 78 and 79. Weight Square D All Rights Reserved 7/98
77 Selection - 3-pole bimetallic and solid state overload relays Class 0 q bi-metallic overload relays, LRk-D Thermal overload relays - ambient compensated with manual or automatic reset - relay trip indicator - for AC or DC - with or without single phase sensitivity LR-D5kk LR-D5kk Short -circuit protection for North American applications Relay setting range European type fuses maximum rating By circuit breaker By fuses For direct mounting beneath contactor Select in accordance with NEC and local codes Maximum 00% of motor FLA Catalog number am gg BS88 LC LP With single phase Without single phase A A A A sensitivity sensitivity kg (lb.).5 to D09 to D3 D09 to D3 LR-D508 LR3-D (0.8) to D09 to D3 D09 to D3 LR-D50 LR3-D (0.8) 5.5 to D09 to D3 D09 to D3 LR-D5 LR3-D (0.8) 7 to D09 to D3 D09 to D3 LR-D5 LR3-D (0.8) 9 to D to D3 D to D3 LR-D56 LR3-D (0.8) to D8 to D3 D8 to D3 LR-D5 LR3-D (0.8) 7 to D5 and D3 D5 and D3 LR-D5 LR3-D (0.8) 3 to D5 and D3 D5 and D3 LR-D553 LR3-D (0.759) 7 to D0 to D95 D0 to D80 LR-D35 LR3-D (.79) 3 to D0 to D95 D0 to D80 LR-D3553 LR3-D (.79) 30 to D0 to D95 D0 to D80 LR-D3555 LR3-D (.79) 37 to D50 to D95 D50 to D80 LR-D3557 LR3-D (.79) 8 to D50 to D95 D50 to D80 LR-D3559 LR3-D (.79) 55 to D65 to D95 D65 to D80 LR-D356 LR3-D (.79) 63 to D80 and D95 D80 LR-D3563 LR3-D (.79) Class 0 and 0 q solid state overload relays, LR9D Weight Thermal overload relays - ambient compensated and single phase sensitivity - trip indicator - for AC only - for direct mounting on contactor or independent panel mounting a LR-D35kk Short -circuit protection for North American applications Relay setting range European type fuses maximum rating am gg LC By circuit breaker By fuses For direct mounting beneath contactor Select in accordance with NEC and local codes Maximum 00% of motor FLA Catalog number Weight A A A kg (lb.) Class 0 q 90 to D5 and 50 LR9-D (.97) Class 0 q 90 to D5 and 50 LR9-D (.97) a Power terminals can be protected against direct finger contact by the addition of an LA9-F03 insulated terminal block, to be ordered separately (see page 79). q Standard IEC 97- specifies a tripping time for 7. times the setting current I R : Class 0: between and 0 seconds Class 0: between and 0 seconds 7/ Square D All Rights Reserved 77
78 Selection overload relay accessories LA7-D06 DX-AP5 LA7-D305 LR-D LR-D LR3-D LA7-D03 R LA7-D03 LA7-D06 LA7-D90 DX-AP6 LR-D ZA-BZ3 LA7-D00 LR-D LR3-D ZA-BL3 LA7-D306 LA7-D90 LA7-D00 ZA-BZ3 ZA-BA LR-D3 LR3-D3 998 Square D All Rights Reserved 7/98
79 Selection overload relay accessories Accessories LRk-D (to be ordered separately) LA9-F03 Drawing of lug DXFG must be made Description For use with relays Sold in lots of Catalog number Terminal blocks for clip-on mounting on 35 mm DIN rail (AM-DP00) or for screw mounting. Power terminals adaptor for mounting an LRk-D3 overload relay beneath an LC-D0, D50 or D65 contactor Power terminals adaptor for mounting an LR-D3 overload relay beneath an LC-D5 or D50 contactor Mounting plates for screw mounting on.33 in. (0 mm) centers Weight kg (lb.) LR-D, LR3-D LA7-D06 c 0.00 (0.0) LR-D, LR3-D LA7-D06 c o.0 (0.6) LR-D3, LR3-D3 LA7-D306 c a 0.05 (0.5) LR-D3, LR3-D3 LA7-D (0.76) LR-D3 LA7-D (0.76) LR-D, LR3-D 0 DX-AP5 q (0.3) LR-D, LR3-D 0 DX-AP6 q 0.08 (0.80) LR-D3, LR3-D3 LA7-D90 q 0.30 (0.86) Marker holder snap-in LR-D, LR3-D, LR9-D 00 LA7-D (0.00) Bag of 00 labels (blank, self-adhesive) 0.76 x in. (7 x 6 mm) LA9-D (0.00) Locking device for Stop button LR-D, LR3-D 0 LA7-D (0.0) Remote tripping and electrical reset device LR-D, LR3-D, LR9-D u LA7-D03 k f t (0.98) IP0 Finger-safe terminal block for power cabling LR9-D LA9-F (.3) Extruded lugs for power cabling LR9-D LR9-D DZ-FG DZFG6 (pkg. of 6) Reset function By flexible cable (length =.6 ft., 0.5 m) LR-D, LR3-D, LR9-D LA7-D (0.65) Stop and/or Reset function For mounting, remove the terminal protection shrouds and order the following 3 products: Adaptor for door mounted operator LR-D, LR3-D, LR9-D LA7-D (0.0) Rod (snap-off end to obtain required length between.670 and.78 in., 7 and 0 mm) LR-D, LR3-D, LR9-D 0 ZA-BZ (0.0) Operating head for spring return pushbutton LR9-D LR-D, LR3-D ZA-BL3 (red) ZA-BA639 (blue) 0.0 (0.06) c Terminal blocks are supplied with terminals protected against direct finger contact and ready-to-tighten screws. a Add suffix 6 for terminals for ring type connectors. For example: LA7-D306 becomes LA7-D3066. q Remember to order the LA7-Dk06 terminal block corresponding to the overload relay size. f The time for which the coil of remote tripping and electrical resetting device LA7-D03 can remain energized depends on its rest time: s pulse duration with 9 s rest time; 5 s pulse duration with 30 s rest time; 0 s pulse duration with 90 s rest time; maximum pulse duration of 0 s with a rest time of 300s. Minimum impulse time: 00 ms. t Reference to be completed by adding the coil voltage code below. t Control circuit voltages Volts /30 380/00 5/0 50/60 Hz AC B E F M Q N Consumption, inrush and sealed: < 00 VA DC J B E DD F M Consumption, inrush and sealed: < 00 W. u For remote reset applications only when used with LR9Dkkkk solid state overload relays. 7/ Square D All Rights Reserved 79
80 Dimensions 3-pole bi-metallic overload relays LR or LR3-D LR, LR3-D Mounting beneath contactors LC-D09 to D3, LP-D09 to D38 and LP-D AM-Dkkkk 35mm DIN rail AM-DP00 AM-DE00 d 9.5 b c c e g LC-D09, D, D e LC-D b LC-D3, D () LP-D09, D, D c d 8 7 g LP-D LP-D LP-D c + 5 mm for LR-D5kk LR, LR3-D Direct mounting beneath contactors LC-D5 to D38, LP-D5 and D3 35mm DIN rail AM-DP00 AM-DE00 AM-Dkkkk d 9.5 b c e g LC-D LC-D3, D e LP-D b LP-D c d 3 5 g LR, LR3-D3 Direct mounting beneath contactors LC-D0 to D95 and LP-D0 to D80 AM-DLkkk 75mm DIN rail AM-DL0 AM-DL00 d 7 7 e b c e g (3P) g (P) LC-D LC-D LC-D LC-D b LC-D LP-D LP-D c d g LP-D LP-D Square D All Rights Reserved 7/98
81 Dimensions 3-pole bimetallic and solid-state overload relays LR -D LR-D bimetallic overload relay Direct mounting beneath contactors LC-D5 and D50 3 d 0 35mm DIN rail dimensions AM-DP00 and DR00 AM-DEkkk and EDkkk d LR9-D solid-state overload relay Direct mounting beneath contactors LC-D5 and D d 0 35mm DIN rail dimensions AM-DP00 and DR00 AM-DEkkk and EDkkk d / Square D All Rights Reserved 8
82 Mounting 3-pole bi-metallic overload relays LR or LR3-D LR, LR3-D Independent mounting on 50 mm centers or on 35mm wide DIN rail AM-DP00 or DE00 5 LA7-D06 = 35 = Independent mounting on 0 mm centers LA7-D06 Dimensions shown in millimeters (mm X.039 = inches) = 6 = /60() 5 0 = 98 d xø mm wide DIN rail dimensions AM-DP00 AM-DE00 08 DX-AP5 xø6.5 = d 9.5 () + 5 mm for LR-D5kk LR, LR3-D3, LR9D Remote trip or electrical reset device LA7-D03 c 96 9 () Can be mounted on RH or LH side of relays LR, LR3-D LR, LR3-D Independent mounting on 50 mm centers or on 35mm wide DIN rail AM-DP00 or DE00 55 LA7-D06 = 0 = Independent mounting on 0 mm centers LA7-D06 = 57 = /60 0 = 98 d xø mm wide DIN rail dimensions 08 AM-DP00 AM-DE00 d 9.5 Remote tripping or electrical reset device = 5 DX-AP6 xø6.5 LA7-D03 c 96 9 c Can be mounted on RH or LH side of relays LR, LR3-D Square D All Rights Reserved 7/98
83 Mounting 3-pole bi-metallic and solid-state overload relays LRk-D LR, LR3-D Independent mounting on 50 mm centers or on 35mm wide DIN rail AM-DP00 or DE00 75 LA7-D306 = 50 = Independent mounting on 0 mm centers LA7-D306 LA7-D90 Dimensions shown in millimeters (mm X.039 = inches) = 75 = /87 6 3xØ6.5 0 d xø = 0 = 35mm wide DIN rail dimension AM-DP00 AM-DE00 d 9.5 () + 5 mm for LR-D5ii LR, LR3-D3, LR9D Remote trip or electrical reset LA7-D03 c 9 c Can be mounted on RH or LH side of relays LR, LR3-D. For mounting on RH side of LR9D only for remote reset applications. Will not mount on LH side of LR9D for remote tripping applications. 7/ Square D All Rights Reserved 83
84 Mounting 3-pole bi-metallic and solid-state overload relays LA7-D00 Adaptor for door mounted operator Stop Reset c 0 Dimensions shown in millimeters (mm X.039 = inches) c: adjustable from 7 to 0 mm LA7-D00 LA7-D305 Reset by flexible cable Mounting with cable straight Mounting with cable bent LA7-D305 e c e M0x c: up to 550 mm e: up to 0 mm e: up to 0 mm Square D All Rights Reserved 7/98
85 Low consumption contactors LP-D contactors and LP5-D reversing contactors operate on a low-level DC supply. Their low consumption operating coil allows direct control from solid state outputs without the need for additional interface modules or interposing relays in the control circuit. They are available in versions: LP-D0 Contactors with standard low consumption coil. Contactors with low consumption coil with bidirectional peak limiting diode for built-in suppression. This version provides a perfect working combination between power and electronic circuits. Contactors with wide range low consumption coils, allowing correct operation between 0.7 and.5 of the control voltage Uc. These are essential where solid state components are connected in series with the control circuit or on machines based on special-purpose electronic cards. Contactors LP-D and LP5-D can be used for the control of motors in category AC-3 up to 5 A (5 hp at 60 VAC). Contactors with wide range low consumption coils with built-in suppression as standard via bidirectional peak limiting diode, allowing correct operation between 0.7 and.5 of the control voltage (Uc). Benefits Low heat dissipation: allowing higher component density in control panels. Use on battery supplies: for on-board equipment, use on battery supply allows easy backup and independent supply shared with programmable controllers. Thermal protection: Telemecanique bi-metallic overload relays can be used with these low consumption contactors. Uniform design: low consumption contactors are the same size as standard contactors LC-D09 and LC-D. Variable composition: low consumption contactors can be fitted with special front-mounting auxiliary blocks. LP-D contactors can also be fitted with electronic serial timer modules LA-DT and Auto-Man- Stop interface modules LA-DM. + DC supply Programmable Logic Controller Printed Circuit Board CA-D LC-F LP5-D LP-D LR9F LR-D LR-D 7/ Square D All Rights Reserved 85
86 Characteristics - Low consumption contactors LP-D and LP5-D Environment Conforming to standards Meets the essential requirements of the LV & EMC directives IEC 58-, 55-, 337-, 97- and 97-, VDE 0660, NF C 63-0 and 5-50, BS 5, JIS C835, JEM 038 Approvals E686 CCN NLDX LR336 Class 3 0 ASE, UL, CSA, DEMKO, NEMKO, SEMKO, FI Protective treatment Standard version TH Degree of protection Conforming to VDE 006 Protection against direct finger contact Maximum operating altitude Without derating 3000m (9800 ft.) Ambient air temperature around the device Storage - 0 to + 80 C ( F) Operating positions for ambient temperature 55 C (3 F) Operation (0.8 to. Uc) For operation at Uc Without derating in the following positions - 5 to + 55 C ( F) - 5 to + 70 C (-3 to +58 F) Power pole cabling Tightening torque Stranded cable without cable end Stranded cable with cable end Solid cable without cable end Control connections Power connections conductor conductors LPk-D AWG 7 to 7 to LPk-D8 mm to to LPk-D5 AWG 6 to 0 mm.5 to 6 6 to 0.5 to 6 LPk-D AWG 7 to 7 to LPk-D8 mm to to LPk-D5 AWG 7 to 0 mm to 6 7 to to LPk-D AWG 7 to 7 to LPk-D8 mm to to LPk-D5 AWG 6 to 0 mm.5 to 6. Nkm (0 lb.-in.). Nkm (0 lb.-in.) 6 to 0.5 to Square D All Rights Reserved 7/98
87 Characteristics - Low consumption contactors LP-D and LP5-D Control circuit characteristics Rated insulation voltage Conforming to VDE D0 (group C) V 50 Conforming to IEC 58-, BS 5 V 50 Conforming to CSA C- n V 300 Maximum voltage Of the control circuit, a V 7 Shock resistance c / sine wave ms Vibration resistance c 5 to 300 Hz Average consumption DC supply Operating time a at Uc and at 68 F (0 C) Contactor open Contactor closed Contactor open Contactor closed Standard coil (0.8 to. Uc) Wide range coil (0.7 to.5 Uc) C O c Without change of contact state, in the least favorable direction. a Closing time C is measured from the moment the coil supply is switched on to initial contact of the main poles. Opening time O is measured from the moment the coil supply is switched off to the moment the main poles separate. 0 gn gn 5 gn 0 gn Inrush Sealed LPk-D W.. LPk- D8 W.6.6 LPk-D5 W LPk-D W.6.6 LPk-D8 W LPk-D5 W.. LPk-D ms 60 LPk-D8 ms 50 LPk-D5 ms 60 LPk-D ms 5 LPk-D8 ms 5 LPk-D5 ms 5 Operational 0.8 to. Uc Control circuit voltage limits θ 3 F, (55 C) Drop-out 0. to 0.3 Uc Time constant (L/R) ms 0 Mechanical life LP-Dkk 30 In millions of operating cycles (mechanical durability) LP5-Dkk 0 Maximum operating rate At ambient temperature 3 F (55 C) Op cycs/h / Square D All Rights Reserved 87
88 Characteristics - Low consumption contactors LP-D and LP5-D Pole characteristics Rated insulation voltage Conforming to VDE 00 C V 750 To IEC 58-, 97-, BS 5, NF C 0-00 V 690 Conforming to CSA C - n, UL 508 V 600 Rated impulse withstand voltage (U imp) kv 8 Conventional rated thermal current (Ith) For θ 0 F (0 C) LPk-D A 0 LPk-D8 A 5 LPk-D5 A 0 Frequency limits Hz 5 to 00 Rated operational voltage (Ue) V 690 Rated making capacity Conforming to IEC 58- LPk-D A 30 and IEC 97- LPk-D8 A 300 LPk-D5 A 30 Rated breaking capacity Conforming to IEC 58- and IEC 97- V /690 I rms LPk-D A LPk-D8 A LPk-D5 A Permissible short time rating In free air, for s 5 s 0 s 30 s min 3 min 0 min from cold state (θ 0 F, 0 C) LPk-D A LPk-D8 A LPk-D5 A Pole impedance At 50 Hz, at Ith mω 3 Operation in category AC- Maximum operational current θ 0 F (0 C) θ 3 F (55 C) (resistive circuits, heating, lighting) LPk-D A 0 6 LPk-D8 A 5 0 LPk-D5 A 0 3 Rated operational power, V 0/30 380/ /690 depending on voltage 50 or 60 Hz 3-phase LPk-D kw LPk-D8 kw LPk-D5 kw Increase in operational thermal current by parallel poles in parallel : k =.6 connection of poles. Apply these coefficients to the maximum currents above. The coefficients take into account the often unbalanced current distribution between poles. Use connecting links to connect poles 3 poles in parallel : k =.5 in parallel. Operation in category AC-3 Rated operational power, depending V 0/30 380/ /690 (squirrel cage motors) on voltage 50 or 60 Hz 3-phase. LPk-D kw Standard motor power ratings LPk-D8 kw LPk-D5 kw Motor power ratings conforming to UL, CSA V LPk-D hp LP-D8 hp LP5-D8 hp LP-D5 hp LP5-D5 hp Maximum operating rate (in cycles/hour) depending On-load factor Operational power Cycles/hour on the % of the rated operational power P 85 % P % 0.5 P % P 800 Short circuit protection By circuit breaker Select in accordance with NEC and local codes By fuses Maximum 0% of motor FLA Square D All Rights Reserved 7/98
89 Characteristics - Low consumption contactors LP-D and LP5-D Electrical life Utilization category AC- and operational voltage <0 V LP -D LP -D8 Millions of operating cycles LP -D5 3 0,8 0,6 0, 0, 0, Current broken in A Utilization category AC-3 and operational voltage < 0 V Millions of operating cycles LP -D LP -D8 LP -D5 3.5,5.5, Current broken in A 7/ Square D All Rights Reserved 89
90 References Low consumption contactors Kilowatt ratings for international applications 3-pole contactors for Finger-safe terminals for power cabling Standard power ratings of 3-phase motors 50/60 Hz in category AC-3 0V 30V 380V 00V 5V 0V 500V 660V 690V Rated operational current in AC-3 0 V up to Maximum operational current in AC- θ 55 C Instantaneous auxiliary contact Catalog number. Complete with code indicating control circuit voltage a q Weight kw kw kw kw kw kw A A N/O N/C DIN rail or mounting c kg (lb.) LP-D0BD LP-D090kk(k) 0.35 (0.693) LP-D090kk(k) 0.35 (0.693) LP-D0kk(k) 0.35 (0.693) LP-D0kk(k) 0.35 (0.693) LP-D80kk(k) 0.30 (0.70) LP-D80kk(k) 0.30 (0.70) LP-D500kk(k) (0.78) c Clip-on mounting on 35 mm DIN rail AM-DP or screw mounting. Power terminals: protected against direct finger contact and ready-to-wire terminals a Coil selection Standard coils (0.8 to. Uc) q Volts AC Code AD JD BD ED SD Coils fitted with integral bidirectional peak limiting diode suppressor (0.8 to. Uc) q Volts AC Code AD3 JD3 BD3 ED3 SD3 Wide range coils (0.7 to.5 Uc) q Volts AC 8 7 Operating range 7 to 30 V 3 to 60 V 50 to 90 V Code BW EW SW Wide range coils fitted with integral bidirectional peak limiting diode suppressor (0.7 to.5 Uc) q Volts AC 8 7 Operating range 7 to 30 V 3 to 60 V 50 to 90 V Code BW3 EW3 SW3 q Coil not interchangeable Square D All Rights Reserved 7/98
91 Horsepower ratings for North American applications 3-pole contactors for Finger-safe terminals for power cabling References Low consumption contactors Maximum horsepower rating -phase 50/60Hz 3-phase 50/60Hz Maximum inductive current in AC-3 category Maximum operational current in AC- θ 55 C Instantaneous auxiliary contact Catalog number. Complete with code indicating control circuit voltage a q Weight LP-D0BD 5V 0V 30V 0V 00V 08V 0V 0V 60V 80V 600V N/O N/C hp hp hp hp hp hp A A DIN rail or mounting c kg (lb.) LP-D090kk(k) 0.35 (0.693) LP-D090kk(k) 0.35 (0.693) LP-D0kk(k) 0.35 (0.693) LP-D0kk(k) 0.35 (0.693) LP-D80kk(k) 0.30 (0.70) LP-D80kk(k) 0.30 (0.70) LP-D500kk(k) (0.78) c Clip-on mounting on 35 mm DIN rail AM-DP or screw mounting. Power terminals: protected against direct finger contact and ready-to-wire terminals a Coil selection Standard coils (0.8 to. Uc) q Volts AC Code AD JD BD ED SD Coils fitted with integral bidirectional peak limiting diode suppressor (0.8 to. Uc) q Volts AC Code AD3 JD3 BD3 ED3 SD3 Wide range coils (0.7 to.5 Uc) q Volts AC 8 7 Operating range 7 to 30 V 3 to 60 V 50 to 90 V Code BW EW SW Wide range coils fitted with integral bidirectional peak limiting diode suppressor (0.7 to.5 Uc) q Volts AC 8 7 Operating range 7 to 30 V 3 to 60 V 50 to 90 V Code BW3 EW3 SW3 q Coil not interchangeable. 7/ Square D All Rights Reserved 9
92 References Low consumption reversing contactors Pre-assembled, horizontally mounted, pre-wired power connections Kilowatt ratings for international applications 3-pole reversing contactors for Finger-safe terminals for power cabling Pre-wired power connections Standard power ratings of 3-phase motors 50/60 Hz in category AC-3 0V 30V 380V 00V 5V 0V 500V 660V 690V Rated operational current in AC-3 0 V up to Maximum operational current in AC- θ 55 C Instantaneous auxiliary contact Catalog number. Complete with code indicating control circuit voltage a q Weight LP-D0BD kw kw kw kw kw kw A A N/O N/C DIN rail or mounting c kg (lb.) LP5-D090kk(k) (.7) LP5-D0kk(k) (.7) LP5-D80kk(k) (.96) LP5-D500kk(k) (.69) c Clip-on mounting on 35 mm DIN rail AM-DP or screw mounting. Power terminals: protected against direct finger contact and ready-to-wire terminals a Coil selection Standard coils (0.8 to. Uc) q Volts AC Code AD JD BD ED SD Coils fitted with integral bidirectional peak limiting diode suppressor (0.8 to. Uc) q Volts AC Code AD3 JD3 BD3 ED3 SD3 Wide range coils (0.7 to.5 Uc) q Volts AC 8 7 Operating range 7 to 30 V 3 to 60 V 50 to 90 V Code BW EW SW Wide range coils fitted with integral bidirectional peak limiting diode suppressor (0.7 to.5 Uc) q Volts AC 8 7 Operating range 7 to 30 V 3 to 60 V 50 to 90 V Code BW3 EW3 SW3 q Coil not interchangeable Square D All Rights Reserved 7/98
93 D-Line Contactors, Overload Relays and Accessories Selection Low consumption reversing contactors Pre-assembled, horizontally mounted, pre-wired power connections Horsepower ratings for North American applications 3-pole reversing contactors with Finger-safe terminals for power cabling LP5-D0BD Maximum horsepower rating -phase 50/60Hz 3-phase 50/60Hz 5V 0V 30V 0V 00V 08V 0V 0V 60V 80V 600V Maximum inductive current in AC-3 category Maximum operational current in AC- θ 55 C Instantaneous auxiliary contact Catalog number. Complete with code indicating control circuit voltage a q hp hp hp hp hp hp A A DIN rail or mounting c kg (lb.) LP5-D090kk(k) (.7) LP5-D0kk(k) (.7) LP5-D80kk(k) (.96) LP5-D500kk(k) (.69) Weight c Clip-on mounting on 35 mm DIN rail AM-DP or screw mounting. Power terminals: protected against direct finger contact and ready-to-wire terminals a Coil selection Standard coils (0.8 to. Uc) q Volts AC Code AD JD BD ED SD Coils fitted with integral bidirectional peak limiting diode suppressor (0.8 to. Uc) q Volts AC Code AD3 JD3 BD3 ED3 SD3 Wide range coils (0.7 to.5 Uc) q Volts AC 8 7 Operating range 7 to 30 V 3 to 60 V 50 to 90 V Code BW EW SW Wide range coils fitted with integral bidirectional peak limiting diode suppressor (0.7 to.5 Uc) q Volts AC 8 7 Operating range 7 to 30 V 3 to 60 V 50 to 90 V Code BW3 EW3 SW3 q Coil not interchangeable. 7/ Square D All Rights Reserved 93
94 D-Line Contactors, Overload Relays and Accessories Selection Accessories for low consumption contactors LA9-D6 LA-DMK LA9-D60 LA9-D6 LA-DT LA9-D63 LP5-D LP-D LA9-D9 LN-DN LA9-D90 LA9-D93 LA9-D9 LR-D Square D All Rights Reserved 7/98
95 Type LPk-D Accessories (to be ordered separately) Instantaneous auxiliary contact blocks D-Line Contactors, Overload Relays and Accessories Selection Accessories for low consumption contactors Front clip-on mounting on Number of contacts Composition Catalog number Weight N/O N/C kg (lb.) LP, LP5 LN-DN (0.066) Electronic serial timer modules Type Time delay For use on Operational voltage c Catalog number Weight kg (lb.) 0. to s LP, LP5 AC /7 V LA-DT0U 0.00 (0.088) On-delay.5 to 30 s LP, LP5 AC /7 V LA-DTU 0.00 (0.088) 5 to 500 s LP, LP5 AC /7 V LA-DTU 0.00 (0.088) Auto-Man-Stop control module For local override operation tests For use on Operational voltage Catalog number Weight kg (lb.) With O-I switch and -position Auto-Man switch LP, LP5 AC /7 V LA-DMK 0.00 (0.088) 3-pole bi-metallic overload relays Compensated, with manual or automatic reset For mounting beneath contactor Relay setting range Type Catalog number Weight kg (lb.) LP or LP5 Accessories 0. to 0.6 A up to 7 to 5 A With single-phase sensitivity LR-Dkkk a 0.65 (0.363) Without single-phase sensitivity LR3-Dkkk a 0.65 (0.363) Description For use on Sold in lots of Catalog number Weight kg (lb.) Connector for cable connection c For V operation, the contactor must have a V wide range coil (code BW). a Basic reference, to be completed: see page 76 and 77. -pole, 0 mm LPk-D09, D, D8 LA9-D (0.066) 3-pole, 5 mm LPk-D5 LA9-D (0.088) poles LP-D09, D, D8 0 LA9-D6 0.0 (0.06) Paralleling links for 3 poles LP-D09, D, D8 0 LA9-D (0.007) poles LP-D09, D, D8 LA9-D (0.053) 8 x mm clip-in legend holder LP, LP5 00 LA9-D (0.00) 8 x 7 mm clip-in legend holder LN-DN 00 LA9-D (0.00) Bag of 300 blank, self-adhesive legend plates - 7 x mm Marker holder LA9-D9 LA9-D (0.00) Bag of 00 blank, self-adhesive legend plates - 7 x 6 mm Marker holder LA9-D90 LA9-D (0.00) 7/ Square D All Rights Reserved 95
96 D-Line Contactors, Overload Relays and Accessories Characteristics - Low consumption contactors type LP-D Auxiliary contact blocks Type LP, LP5 LN-DN Instantaneous auxiliary contact characteristics (add-on or integral) Number of contacts (LP-D09, D, D8) Rated operational voltage Conforming to IEC 97-5; up to V Rated insulation voltage (Ui) Conforming to IEC 97-5 V Conforming to UL, CSA V Rated thermal current (Ith) For ambient temperature 0 C A 0 6 Minimum switching capacity U V 7 7 I ma 5 5 Short-circuit protection To IEC and VDE gg fuse. Rated making capacity (rms) Conforming to IEC A 0 80 Permissible short time rating For s A ms ms 0 80 Insulation resistance MΩ > 0 > 0 Non-overlap time Guaranteed between N.C. and N.O. contacts ms,5 Mechanical durability In millions of operating cycles Breaking limit of contacts for: a maximum of 50 operating cycles, at 0 s intervals (power broken = making power x ϕ 0.7). Electrical durability of contacts: - for million operating cycles (a), - for 3 million operating cycles (b), - for 0 million operating cycles (c). 3 Breaking limit of contacts for: a maximum of 0 operating cycles, at 0 s intervals and with current passing for 0.5 s per operating cycle. Thermal limit. AC supply, categories AC- and AC-5 Power broken in VA V a b c DC supply, category DC-3 Power broken in W / V a b c Square D All Rights Reserved 7/98
97 D-Line Contactors, Overload Relays and Accessories Dimensions, mounting Low consumption contactors and reversing contactors Type LPk-D Dimensions shown in millimeters (mm X.039 = inches) Dimensions LP-D LP5-D 0 c 0 c b b (LA-DT) b (LA-DM) b b (LA-DT) b (LA-DM) c (LN-DN) 5 c (LN-DN) 03 b b b c c b b b c c LP-D09, D, D LP5-D09, D, D LP-D LP5-D Mounting LP-D LP5-D on rail AM-D00 on panel with #8 screws on rail AM-D00 on panel xø5 xø5 = = = 60 = = = 60 = = c = 35 = c = 9 = LPk-D09 LPk-D LPk-D8 LPk-D5 AM-DP AM-DE Mounting of contactors LP, LP5-D09, D & D8 with bi-metallic overload relay LRk-D Mounting of contactors LP, LP5-D5 with bi-metallic overload relay LRk-D d d mm wide DIN rail dimension 35mm wide DIN rail dimension d d AM-DP00 AM-DP00 AM-DE AM-DE / Square D All Rights Reserved 97
98 D-Line Contactors, Overload Relays and Accessories Schemes - Low consumption contactors and reversing contactors Type LPk-D Contactors LP-Dkk0 3P + N.O. LP-Dkk0 3P + N.C. LP-D500 3P Reversing contactors LP5-Dkk0 3P + N.O. LP5-D500 3P U V W U V W A 6 6 A A 6 6 A A A A A L L L3 L L L3 A A T/ /L T/ 3/L T3/6 5/L3 3/NO A A T/ /L T/ 3/L T3/6 5/L3 /NC A A T/ /L T/ 3/L T3/6 5/L3 LP5-D09-D-D8 Integral electrical interlocking of the contactors Add-on auxiliary contact block LN-DN N.C. + N.O. A A A A K K 53/NO 5 6 /NC K K Square D All Rights Reserved 7/98
99 D-Line Contactors, Overload Relays and Accessories Schemes - Low consumption contactors and reversing contactors STANDARD CONTACTORS Capacitors, together with the circuits to which they are connected, form oscillatory circuits which can, at the moment of switch-on, give rise to high transient currents (> 80 In) at high frequencies ( to 5 khz). As a general rule, the peak current on energization is lower when: the mains inductances are high, the line transformer ratings are low, the transformer short-circuit voltage is high, the ratio between the sum of the ratings of the capacitors already switched into the circuit and that of the capacitors to be switched in is small (for multiple step capacitor banks). In accordance with standards IEC 70, NF C 5-00, VDE 0560, the switching contactor must be able to withstand a continuous current of.3 times the rated current of the capacitor bank step being switched. The rated operational powers given in the tables opposite take this overload into account. Short-circuit protection is normally provided by gl type HRC fuses rated at.7 to In. CONTACTOR APPLICATIONS Operating conditions Capacitors are directly switched. The values of peak current at switch-on must not exceed the values indicated opposite. An inductor may be inserted in each of the three phases supplying the capacitors to reduce the peak current, if necessary. Inductance values are determined according to the selected operating temperature. Power factor correction by a single-step capacitor bank The use of a choke inductor is unnecessary : the inductance of the mains supply is adequate to limit the peak to a value compatible with the contactor characteristics. Power factor correction by a multiple-step capacitor bank Select a special contactor as defined on page. If a standard contactor is used, it is essential to insert a choke inductor in each of the three phases of each step. 7/ Square D All Rights Reserved 99
100 D-Line Contactors, Overload Relays and Accessories Selection guide for switching three phase capacitors International applications only Capacitor switching Capacitors, together with the circuits to which they are connected, form oscillatory circuits which can, at the moment of switch-on, give rise to high transient currents (> 80 In) at high frequencies ( to 5 khz). As a general rule, the peak current on energisation is lower when: - the mains inductances are high, - the line transformer ratings are low, - the transformer short-circuit voltage is high, - the ratio between the sum of the ratings of the capacitors already switched into the circuit and that of the capacitors to be switched in is small (for multiple step capacitor banks). In accordance with standards IEC 70, NF C 5-00, VDE 0560, the switching contactor must be able to withstand a continuous current of.3 times the rated current of the capacitor bank step being switched. The rated operational powers given in the tables opposite take this overload into account. Short-circuit protection is normally provided by gl type HRC fuses rated at.7 to In. E686 CCN NLDX LR336 Class 3 0 Contactor selection Operating conditions Capacitors are directly switched. The values of peak current at switch-on must not exceed the values indicated on the following page. Inductors may be inserted in each of the three phases supplying the capacitors to reduce the peak current, if necessary. Inductance values are determined according to the selected operating temperature. Power factor correction by a single-step capacitor bank The use of a choke inductor is unnecessary: the inductance of the mains supply is adequate to limit the peak to a value compatible with the contactor characteristics. Power factor correction by a multiple-step capacitor bank Select a special contactor as defined on page. If a standard contactor is used, it is essential to insert a choke inductor in each of the three phases of each step Square D All Rights Reserved 7/98
101 D-Line Contactors, Overload Relays and Accessories Selection guide for switching three phase capacitors Maximum operational power of contactors: International applications only Standard contactors Maximum operating rate: 0 operating cycles/hour. Electrical durability at maximum load: operating cycles. With choke inductors connected, where necessary. Operational power at 50/60 Hz c Upper limit of temperature category conforming to IEC 70. Maximum peak current Contactor θ 0 F (0 C) c θ 3 F (55 C) c 0 V/0 V 00 V/0 V 600 V/690 V 0 V/0 V 00 V/0 V 600 V/690 V kvar kvar kvar kvar kvar kvar A LC-D09, D LC-D LC-D LC-D LC-D LC-D LC-D LC-D80, D LC-F LC-F LC-F LC-F LC-F LC-F LC-F LC-F LC-F LC-BL LC-BM LC-BP LC-BR 7/ Square D All Rights Reserved 0
102 D-Line Contactors, Overload Relays and Accessories Contactors for capacitor switching LC-DkK: International applications only Special contactors Special contactors LC-DkK are designed for switching 3-phase, single or multiple-step capacitor banks; they conform to standards IEC 70 and 83, NFC 5-00, VDE Contactor applications Specification LC-DFKkk Contactors fitted with a block of early make poles and damping resistors, limiting the value of the current on closing to 60 In max. This current limitation at switch-on increases the life of all the components in the installation, in particular that of the fuses and capacitors. The patented design of the add-on block (n ) guarantees the safety and long life of the installation. Operating conditions There is no need to use choke inductors for either single or multiple-step capacitor banks. Short-circuit protection must be provided by gi type fuses rated at.7 to In. Maximum operational power The power values given in the selection table below are for the following operating conditions Prospective peak current at switch-on LC-DkK 00 In Maximum operating rate LC-DFK, DGK, DLK, DMK, DPK 0 operating cycles/hour. LC-DTK, DWK 00 operating cycles/hour. Electrical durability at rated load Operational power at 50/60 Hz θ 3 F, 55 C a 0 V 00 V 660 V LC-DFK, DGK 00 V operating cycles. LC-DLK, DMK, DPK, DTK, DWK 690 V operating cycles. Instantaneous auxiliary contacts Tightening torque on cable end of power tterminals Basic reference. Complete with code indicating control circuit voltage c Weight 0 V 0 V 690 V kvar kvar kvar N.O. N.C. lb-in (N m) lb (kg) (.) LC-DFKkk 0.98 (0.30) 0.66 (.) LC-DFK0kk 0.98 (0.30) (.7) LC-DGKkk 0.99 (0.50) 5.0 (.7) LC-DGK0kk 0.99 (0.50) (.9) LC-DLKkk.3 (0.600) 6.88 (.9) LC-DLK0kk.3 (0.600) (.5) LC-DMKkk.389 (0.630). (.5) LC-DMK0kk.389 (0.630) (5) LC-DPKkk.866 (.300) (5) LC-DTKkk.866 (.300) (9) LC-DWKkk 3.60 (.650) LC-DPKkk Switching of multiple capacitor banks (with equal or different power ratings). The correct contactor for each step is selected from the above table, according to the power rating of the step to be switched. Example: 50 kvar 3-step capacitor bank. Temperature: F (50 C) and U = 00 V or 0 V. One 5 kvar step: contactor LC-DMK, one 5 kvar step: contactor LC-DGK and one 0 kvar step: contactor LC-DFK. c Standard control circuit voltages c Coil selection Volts Hz B5 D5 E5 F5 M5 P5 U5 Q5 V5 N5 R5 S5 Y5 60 Hz B6 D6 E6 F6 M6 U6 Q6 R6 50/60 Hz B7 D7 E7 F7 M7 P7 U7 Q7 V7 N7 R7 a The average temperature over a -hour period, in accordance with IEC 70 and 83 is 3 F (5 C) Square D All Rights Reserved 7/98
103 D-Line Contactors, Overload Relays and Accessories Contactors for capacitor switching Dimensions LC-DFK, DGK LC-DPK, DTK c LC- c Contactor LC- Contactor DFK 7 LC-D DPK LC-D0 DGK LC-D8 DTK LC-D50 LC-DLK, DMK LC-DWK c LC- c Contactor LC- Contactor DLK 7 LC-D5 DWK LC-D80 DMK LC-D3 Schemes LC-DkK () A A /T /L 3/L 5/L3 } R /T 6/T3 R R = Resistor connections, pre-wired () Mains supply () Application } () (3) } (3) Do not connect anything to these 3 auxiliary poles Cabling Contactor type LC- DFK DGK DLK DMK DPK, DTK DWK Number of conductors Stranded cable with cable end Solid cable without cable end / Square D All Rights Reserved 03
104 D-Line Contactors, Overload Relays and Accessories Plate-mounted starters LC-D: International applications only Contains UL listed, CSA certified, CE marked components. Assemblies are not UL listed or CSA certified. Includes contactor and European style fused disconnect switch on mounting plate. LC-D09kk Utilization category AC-3 Fuses to be fitted by Catalog number. Weight the customer Complete with code Standard power ratings of 3-phase motors Operational indicating control 50/60 Hz current circuit voltage a c 0/30 V 380/00 V 5 V 0 V 500 V 660/690 V 0 up to Size Class am kw kw kw kw kw kw A A kg (lb.) x 38 LC-D09kk (.98) x 38 6 LC-Dkk (.98) x 38 0 LC-D8kk.50 (.535) x 38 5 LC-D5kk.580 (3.83) x 5 3 LC-D3kk.630 (5.798) x 5 0 LC-D0kk.930 (6.59) x LC-D50kk 3.00 (7.05) x LC-D65kk 3.30 (7.363) x LC-D80kk (8.07) Specifications Pre-wired power and control circuit connections 3-pole off-load switch fuse: LC-D09 to D80 c Thermal overload relay to be ordered separately (see pages 76 and 77). a Coil selection Volts 8 0 0/ / /60 Hz B7 D7 E7 F7 M7 P7 U7 Q7 V7 N7 R7 LC-D0kk Square D All Rights Reserved 7/98
105 D-Line Contactors, Overload Relays and Accessories Plate mounted starters - Dimensions and wiring diagrams LCD: International applications only Plate mounted starters LC-D09, D, D8, D xø. LC-D3 xø6. b c c c () = = = = 00 0 () 60 () (3) = = LC- b c c c D09, D D D c with LA-Dkkk () with LA-Dkkk c with LA-Dkk or LA3-Dkk () with LA-Dkk or LA3-Dkk () + mm with lead sealing kit (3) + mm with lead sealing kit LC-D0, D50, D65, D80 LC- a b b c c c c3 G xø7 D Plate mounted starters c c c () c3 b b = G = a xø7 = 60 = = 00/0 = D50, D65 D c with LA-Dkkk c with LA-Dkk or LA3-Dkk () + mm with lead sealing kit Note: Dimensions are expressed in millimeters. To calculate inches, multiply by For example, mm = (0.039) in. =.73 LC-D09 to D80 LC-D09 to D5 LC-D3 to D80 Q/ 0 9 Q/ Q F Q Q KM /L U 3/L 3 3 V 5/L3 W Commande à distance N Q/6 3 KM KM A A Commande à distance N Q/6 3 3 Q KM KM A A 7/ Square D All Rights Reserved 05
106 D-Line Contactors, Overload Relays and Accessories Wye-Delta starters LC3-D: International applications only Wiring methods differ from typical North American practice. Contains UL listed, CSA certified, CE marked components. Assemblies are not UL listed or CSA certified. Standard power ratings of squirrel cage motors Auxiliary contacts available on each contactor Star-delta mechanical interlock Catalog number. Complete with code indicating control circuit voltage a c Weight line KM delta KM3 star KM Mains voltage - delta connection 0 V 380 V 5 V 0 V kw kw kw kw kg (lb.) Plate mounted LC3-Dkk Maximum operating rate: 30 starts/hour. Maximum starting time: 30 seconds. Without LC3-D09kk.500 (3.306) q With LC3-D09kkA6.530 (3.373) Without LC3-Dkk.500 (3.306) 5.5 q With LC3-DkkA6.530 (3.373) Without LC3-D8kk.700 (3.78) 8.5 q With LC3-D8kkA6.730 (3.8) Without LC3-D3kk.000 (.09) q With LC3-D3kkA6.030 (.75) Without LC3-D0kk.360 (9.6) q With LC3-D0kkA6.500 (9.90) Without LC3-D50kk.360 (9.6) q q With LC3-D50kkA6.500 (9.90) Without LC3-D80kk 5.00 (.6) q q With LC3-D80kkA (.90) Rail mounted (35 mm DIN rail) Maximum operating rate: starts/hour. Maximum starting time: 30 seconds With LC3-K06kk.63 (0.70) With LC3-K09kk.63 (0.70) Maximum operating rate: 30 starts/hour. Maximum starting time: 30 seconds q 5.5 q 8.5 q q Without LC3-D090kk.500 (3.306) With LC3-D090kkA6.530 (3.373) Without LC3-D0kk.500 (3.306) With LC3-D0kkA6.530 (3.373) Without LC3-D80kk.700 (3.78) With LC3-D80kkA6.730 (3.8) Without LC3-D30kk.000 (.09) With LC3-D30kkA6.030 (.75) c Protection must be provided by the addition of an overload relay, to be ordered separately. Select appropriate overload relay for setting at 0.58 of the full load rated motor current. a Coil selection Star-delta starters LC3-K06 and K09 Volts AC 50/60 Hz / /0 Code B7 C7 D7 E7 F7 FC7 M7 P7 U7 Star-delta starters LC3-D09 to D80, LC3-D090 to D30 Volts AC 50/60 Hz 8 0 0/ / Code B7 D7 E7 F7 M7 P7 U7 Q7 V7 N7 R7 For other voltages, please consult your Regional Sales Office. q One auxiliary contact block type LA-Dkkk can also be added Square D All Rights Reserved 7/98
107 D-Line Contactors, Overload Relays and Accessories Wye-Delta starting: International applications only Current Speed Starting in direct delta connection Starting in star connection Torque Starting in direct delta connection Starting in star connection 3 Machine resistive torque Speed This method of starting is only applicable to 3-phase motors whose delta connection corresponds to the mains voltage and on which all 6 stator terminals are accessible. Star-delta starting should be used for motors starting on no-load or having a low load torque and gradual build-up: - the starting torque in star connection is reduced to one third of the direct starting torque, i.e. about 50% of the rated torque; - the starting current in star connection is about.8 to.6 times the rated current. The transition from star to delta connection must occur when the machine has run up to speed. A too rapid build-up in load torque would cause the stabilised run-up speed to be too low and would therefore eliminate any advantage in this method of starting: this is the case with certain machines whose load torque depends on its speed (a characteristic of centrifugal machines, for example). All star-delta starters are supplied with a special LA-DS or LA-KTk time delay relay which imposes a delay on the delta contactor during the transition period in order to allow the star contactor sufficient breaking time. c Motor manufacturers generally specify machine load torques. Example: maximum resistive torque on completion of star-delta start (expressed as a proportion of the rated torque). 7/ Square D All Rights Reserved 07
108 D-Line Contactors, Overload Relays and Accessories Wye-Delta starting: International applications only Wiring methods differ from typical North American practice d d c c KM a KM3 KM e c b Square D All Rights Reserved 7/98
109 Wiring methods differ from typical North American practice Contains UL listed, CSA certified, CE marked components. Assemblies are not UL listed or CSA certified. Contactors Standard power ratings of squirrel cage motors f Mains voltage - delta connection D-Line Contactors, Overload Relays and Accessories Wye-Delta starter kits: International applications only Contactors (Catalog number. Complete with code indicating control circuit voltage) a c 0 V 380 V 5 V 0 V line delta star kw kw kw kw KM KM3 KM Type Maximum operating rate: 30 starts/hour. Maximum starting time: 30 seconds LC-D090kk LC-D090kk LC-D090kk D LC-D0kk LC-D0kk LC-D090kk D 8.5 LC-D80kk LC-D80kk LC-D090kk D LC-D30kk LC-D30kk LC-D80kk D LC-D0kk LC-D0kk LC-D50kk D LC-D50kk LC-D50kk LC-D0kk D LC-D80kk LC-D80kk LC-D50kk D80 Component parts Description Illustration item no. (p.0) For use on Catalog number Component parts (see below) Assembly kit comprising: D09, D LA9-D (0.397) - instantaneous auxiliary contact block LA-DN (D09 to D0). a D8 LA9-D (0.9) - time delay contact block LA-DS (D09 to D80). b D3 LA9-D (0.683) - power circuit connections (D09 to D80). - screws and clamps for fixing contactors to mounting plate (D0 to D80). c d D0 LA9-D (0.838) - terminal block (D09 to D3). e D50 LA9-D (.058) D80 LA9-D (.99) Equipment mounting plate D09, D, D8 LA9-D (0.33) D3 LA9-D (0.397) D0 and D50 LA9-D (0.66) D80 LA9-D (0.66) c Protection must be provided by the addition of an overload relay, to be ordered separately. Select appropriate overload relay for setting at 0.58 of the full load rated motor current, see pages 76 and 77. a See page 06. q For mounting, assembly and cabling: refer to installation instructions supplied with the equipment. Weight kg (lb.) 7/ Square D All Rights Reserved 09
110 D-Line Contactors, Overload Relays and Accessories Wye-Delta starters Wiring diagrams LE3-D: International applications only Wye-delta starters with isolator LE3-D096 to D806 Q KM 3 5 KM KM Recommended cabling for reversal of motor rotation (standard motor viewed from shaft end). U V W 6 U V 3 5 W U /L 3/L 5/L3 V W U V W Square D All Rights Reserved 7/98
111 Wye-delta starters with isolator LE3-D096 to D6 LE3-D86 to D806 Q/ 0 9 Q/ Q 3 Q F 3 Q O S l KM KM 55 KM KM l (3) KM 5 () 68 KM 55 KM 67 3 KM 68 KM3 KM KM3 KM N KM A KM A KM3 A N KM A KM A KM3 A Q/6 A A A Q/6 A A A ( ) for LE3-D506, D806. 7/ Square D All Rights Reserved
112 Enclosed IEC non-combination starters D-line in metal enclosures Horsepower ratings for North American applications E6336 CCN NKJH CCN NKJH7 LR D-line enclosed full voltage starters are available in Type and Type /3R enclosures through 50 hp at 60V. The enclosed D-line uses LC-D contactors and LR-D overload relays and accepts standard D-line accessories and all Insta-kit pilot device and control power transformer kits. Enclosed full voltage non-reversing startersa Max. Horsepower Ratings (AC3) Auxiliary Contacts Catalog Number c a Weight Catalog Number c a Weight Phase 3 Phase V 30V 60V 575V N.O. N.C. Type lb. Type/3R lb LE--UD0936kk 6.90 LE-UD0937kk LE-UD36kk 6.90 LE-UD37kk LE-UD836kk 6.93 LE-UD837kk LE-UD536kk 7.8 LE-UD537kk LE-UD336kk 9.58 LE-UD337kk LE-UD036kk. LE-UD037kk LE-UD5036kk. LE-UD5037kk LE-UD6536kk 6.8 LE-UD6537kk LE-UD8036kk 6.83 LE-UD8037kk 7.79 c Substitue S in place of in catalog number for single phase devices. Ex: LES-UD0936k Enclosed full voltage reversing startersa Max. Horsepower Ratings (AC3): 3 Phase Auxiliary Contacts Catalog Number Weight Catalog Number Weight 00V 30V 60V 575V N.O. N.C. Type lb. Type/3R lb LE-UD0936kk 9.93 LE-UD0937kk LE-UD36kk 9.96 LE-UD37kk LE-UD836kk 0.08 LE-UD837kk LE-UD536kk - LE-UD537kk LE-UD336kk - LE-UD337kk LE-UD036kk - LE-UD037kk LE-UD5036kk - LE-UD5037kk LE-UD6536kk - LE-UD6537kk LE-UD8036kk - LE-UD8037kk - Coil voltages for enclosed non-combination starters a Coil selection Volts Hz B5 F5 - G5 - M5 U5 - Q5 N5 R Hz B5 F6 G6 - L6 M6 U6 W6 Q6 - R6 T6 S6 X6 50/60Hz B7 F M7 U7 - Q7 N7 R a Bimetallic overload relay must be ordered separately. See Page 07 for thermal overload relay tables. See Pages to 9 for a complete selection of D-line accessories. See Page 6 for Insta-Kit accessories. How to order: To order specify - Type number - Coil voltage code - Insta-Kits - Overload relays Catalog number Type Coil code Insta-kits form Overload relay (separate item) LE-UD0936 F7 AP LR-D Square D All Rights Reserved 7/98
113 Enclosed IEC non-combination starters Overload relays for non-combination starters LE-UD non-combination starter Motor full load current range Amperes For direct mounting under Contactor LE/LE Class 0 Catalog number Class 0 Catalog number.0-.6 DO9-D3 LRD DO9-D3 LRD DO9-D3 LRD DO9-D3 LRD DO9-D3 LRD DO9-D3 LRD DO9-D3 LRD DO9-D3 LRD308 LRD508-6 DO9-D3 LRD30 LRD DO9-D3 LRD3 LRD5 7-0 DO9-D3 LRD3 LRD5 9- D-D3 LRD36 LRD D-D3 LRD3 LRD5 7- D5 LRD3 LRD5 7-5 D3 LRD3 LRD5 3-8 D3 LRD353 LRD D0-80 LRD3353 LRD D0-80 LRD3355 LRD D0 LRD3357 LRD D50-80 LRD3357 LRD D65-80 LRD3359 LRD D80 LRD336 LRD D80 LRD3363 LRD3563 7/ Square D All Rights Reserved 3
114 Enclosed IEC combination starters D-Line in metal enclosure with fusible disconnect switch or circuit breaker Horsepower ratings for North American applications E6336 NKJH NKJH7 LR IEC combination starters combine the requirements of motor overload and short circuit protection in one convenient compact package. All devices provide Type Coordination through 30 hp at 60V. Devices are available in Type and Type /3R enclosures. The IEC combination starter line accepts standard D-line accessories and all Insta-kit pilot device and control power transformer kits. Standard capacity control power transformers with built-in fuse block can be installed in the standard enclosure. Enclosed full voltage non-reversing fusible combination startersa Max. Horse Power Ratings (AC3) Fuse Clip Rating Auxiliary Catalog Number c Weight Catalog Number c Weight 3 Phase Contacts 00V 30V 60V 575V Amperes UL Class N.O. N.C. TYPE lb. Type /3R lb A CC - LE-UD0986kk 8 LE-UD0987kk A CC - LE-UD86kk 8 LE-UD87kk A J - LE-UD886kk 8 LE-UD887kk A J - LE-UD586kk 8 LE-UD587kk A J - LE-UD386kk 6 LE-UD387kk A J LE-UD086kk 8 LE-UD087kk 8 Enclosed full voltage reversing fusible combination startersa Max. Horse Power Ratings (AC3) Fuse Clip Rating Auxiliary Catalog Number c Weight Catalog Number c Weight 3 Phase Contacts 00V 30V 60V 575V Amperes UL Class N.O. N.C. TYPE lb. Type /3R lb A CC LE-UD0986kk 6 LE-UD0987kk A CC LE-UD86kk 6 LE-UD87kk A J LE-UD886kk 6 LE-UD887kk A J LE-UD586kk 6 LE-UD587kk A J LE-UD386kk 7 LE-UD387kk A J LE-UD086kk 3 LE-UD087kk 3 Enclosed full voltage non-reversing circuit breaker combination startersa Max. Horse Power Ratings (AC3) Auxiliary Contacts Maximum Catalog Number c Weight Catalog Number c Weight 3 Phase Current Rating Circuit Breaking 00V 30V 60V 575V N.O. N.C. TYPE lb. Type /3R lb A LE-UD0996kk 0 LE-UD0997kk A LE-UD96kk 0 LE-UD97kk A LE-UD896kk 0 LE-UD897kk A LE-UD596kk 0 LE-UD597kk A LE-UD396kk 7 LE-UD397kk A LE-UD096kk 9 LE-UD097kk 9 Enclosed full voltage reversing circuit breaker combination startersa Max. Horse Power Ratings (AC3) Auxiliary Contacts Maximum Catalog Number c Weight Catalog Number c Weight 3 Phase Current Rating Circuit Breaking 00V 30V 60V 575V N.O. N.C. TYPE lb. Type /3R lb A LE-UD0996kk LE-UD0997kk A LE-UD96kk LE-UD97kk A LE-UD896kk 8 LE-UD897kk A LE-UD596kk 8 LE-UD597kk A LE-UD396kk 8 LE-UD397kk A LE-UD096kk 3 LE-UD097kk 3 acoil selection Volts Hz B5 F5 G5 M5 U5 Q5 N5 R5 60Hz B6 F6 G6 L6 M6 U6 W6 Q6 R6 T6 S6 X6 50/60Hz B7 F7 M7 U7 Q7 N7 R7 How to order: To order specify - Type number - Coil voltage code - Insta-Kits - Overload relays Catalog number Type Coil Code Insta-kits form Overload relay (separate item) LE-UD0986 F7 AP LR-D305 c Thermal overload relay must be ordered separately. See page 5 for selection. a Bimetallic overload relay must be ordered separately. See page 5 for selection. See pages to 9 for a complete selection of D-Line accessories. See page 6 for Insta-Kit accessories. 998 Square D All Rights Reserved 7/98
115 Enclosed IEC combination starters Overload relays for combination starters with fusible disconnect switch or circuit breaker LE-UD enclosed combination starters Current Setting Range For Direct Mounting under Contactor LC/LC Amperes Fusible Circuit Breaker Class 0 Catalog Number Class 0 Catalog Number D09-D5 LR-D D09-D5 LR-D D09-D5 LR-D D09-D5 LR-D D09-D5 LR-D D09-D5 LR-D D09-D5 LR-D D09-D5 LR-D D09-D5 LR-D308 LR-D508-6 D09-D5 D09-D LR-D30 LR-D D09-D5 D09-D LR-D3 LR-D5 7-9 D09-D5 D09-D LR-D3 LR-D5 9 - D-D5 D LR-D36 LR-D D8-D5 D8-D5 LR-D3 LR-D5 7 - D5 D5 LR-D3 LR-D5 7-5 D3 D3 LR-D3 LR-D5 3-8 D3 D3 LR-D353 LR-D D0 D0 LR-D3353 LR-D D0 D0 LR-D3355 LR-D D0 D0 LR-D3357 LR-D3557 7/ Square D All Rights Reserved 5
116 Enclosed IEC combination starters Insta-Kits Insta-Kits prewired prewired pilot device kits and control power transformer kits can be factory installed by selecting the factory modification form number or installed by the customer by selecting the Insta-Kits reference number as a separate item. LA9FFTK Insta-Kits Selection E639 CCN XPTQ CCN XPTQ7 All others E839 CCN NKCR CCN NKCR7 a Replace (*) with the suffix letter corresponding to the pilot light voltage. Voltage V 0V 08/0V 80V Suffix Letter B K P W LR Description Factory Modification Insta-Kit Form Catalog Number On/Off Selector Switch C6 LA9-C6 Hand-Off-Auto Selector Switch C LA9-C Green Pilot Light (0V) P c LA9-P c Red Pilot Light (0V) P c LA9-P c Green Transformer Pilot Light P5 c LA9-P55* ac Red Transformer Pilot Light P5 c LA9-P55* ac Start/Stop Pushbutton A LA9-A Start/Stop (Mushroom Head) Pushbutton A LA9-A I/O (Start/Stop) Pushbutton A6 On/Off Selector Switch with Green Pilot Light (0V) C6P LA9-C6P On/Off Selector Switch with Red Pilot Light (0V) C6P LA9-C6P Hand-Off-Auto Selector Switch with Green Pilot Light CP LA9-CP Hand-Off-Auto Selector Switch with Red Pilot Light CP LA9-CP H-O-A Selector Switch with Green Transformer Pilot Light CP5 LA9-CP55* a H-O-A Selector Switch with Red Transformer Pilot Light CP5 LA9-CP55* a Forward-Reverse-Stop Pushbuttons A LA9-A Start/Stop Pushbutton with Green Pilot Light (0V) AP LA9-AP Start/Stop Pushbutton with Red Pilot Light (0V) AP LA9-AP Start/Stop Pushbutton with Green Transformer Pilot Light AP5 LA9-AP55* a Start/Stop Pushbutton with Red Transformer Pilot Light AP5 LA9-AP55* a Standard Control Transformer with Top Mounted Fuse Block: 50 VA Transformer 80/0V-0V FFT LA9-FFTKF50D 50 VA Transformer 08-0V FFT LA9-FFTKF50D3 00 VA Transformer 80/0V-0V FFT0 LA9-FFTKF00D 00 VA Transformer 08-0V FFT0 LA9-FFTKF00D3 50 VA Transformer 80/0V-0V FFT LA9-FFTKF50D 50 VA Transformer 08-0V FFT LA9-FFTKF50D3 Local/Remote Adapter - Three Wire c LA9-3W Local/Remote Adapter - Four Wire c LA9-W Local/Remote Adapter - Five Wire c LA9-5W Local/Remote Adapter - Seven Wire c LA9-7W Kit for Remote LA9-FK For factory modification, add form number to the end of the catalog number. k LA93W required when START/STOP pushbutton remote station is used in conjunction with START/STOP local control OR if local pilot light only is used. k LA9W required when FOR/REV/STOP is required for both local and remote control. k LA95W required when START/STOP pushbutton with pilot light remote station OR pilot light oly remote is used with START/STOP pushbutton local control. k LA97W required for remote control only applications. Insta-Kits shown with LE-UD non-combination starter Insta-Kits is a trademark of Schneider Canada Square D All Rights Reserved 7/98
117 Approximate dimensions Enclosed combination and non-combination IEC starters Combination starter dimensions Type Dimensions in inches 0" 5" /" 7 /" 8" 3" /" 7 /" / " " 6 / " 8 " Provision for /" screw D09-D5 FVNR Provision for /" screw D09-D5 FVR D3-D0 FVNR and FVR Type /3R 0" 5" /" 3/8" 7 3/" 8" 3" /" 3/8" 7 3/" 5 5/8" 7/8" " 9 5/8 " 8 7/8 " 8 " 7/6" Provision for /" screw 7/6" Provision for /" screw D09-D5 FVNR D09-D5 FVR D3-D0 FVNR and FVR Non-combination starter dimensions A.50 Dimensions shown in inches J K R C B E D D/ PROVISION FOR /" SCREW F G H TYPE TYPE /3R Non-reversing Reversing A B C D E F G H J K D E D / / - 3 / - / / - 3 / D3-50 D / - / / - 3 / - / - / / - 3 / D65-80 D / - / / - 3 / - / - / / - 3 / Type enclosures include conduit knockouts indicated by F, G, H, J and K diameter dimensions. Type /3R enclosures do not include conduit knockouts. For additional information on combination starters, reference catalog number 950HO960. For additional information on non-combination starters, reference catalog number 950HO90. 7/ Square D All Rights Reserved 7
118 Schemes Enclosed IEC non-combination starters Non-reversing, non-combination 3-phase starter LE-UDkk36 and LE-UDkk37 GND A A L L L M 5 6 A3 T T T D0 Only Insta-Kit Harness Receptacle ALARM OL 98 T T T3 96 Non-reversing, non-combination -phase starter LES-UDkk36 and LES-UDkk37 GND A A L L L M 5 6 A3 T T T D0 Only Insta-Kit Harness Receptacle ALARM OL 98 T T T3 96 Reversing, non-combination 3-phase starter LE-UDkk36 and LE-UDkk37 Insta-Kit Harness Receptacle GND A A FWD L L L3 O 3 A A REV L L L3 O F F 5 6 A3 FWD T T T3 O FWD A3 REV T T T3 O REV ALARM OL 98 T T T Square D All Rights Reserved 7/98
119 Schemes Enclosed IEC combination starters Non-reversing, combination 3-phase starter LE-UDkk86 and LE-UDkk87, 97 L L L3 Disconnecting Means T T T3 GND A A FWD L L L F 3 A3 FWD T T T3 Insta-Kit Harness Receptacle Alarm OL D0 Only 98 T T T3 96 Reversing, combination 3-phase starter LE-UDkk86, 96 and LE-UDkk87, 97 L L L3 Disconnecting Means T T T3 A A REV L L L3 O 3 A A FWD L L L3 O 3 R F REV A3 T T T3 O A3 FWD T T T3 O GND T T T3 6 OL 3 Insta-Kit Harness Receptacle 7/ Square D All Rights Reserved 9
120 Enclosed contactors LE-D International applications only Contains UL listed, CSA certified and CE marked components. Assemblies are not UL listed or CSA certified. LE-D093kk LE-D05kk Standard power ratings of 3-phase motors 50/60 Hz in category AC-3 c Overload protection by thermal overload relay, to be ordered separately. Operational current 0 V up to Type of enclosure Basic reference. Complete with code indicating control circuit voltage a 0/30 V 380/00 V 5 V 0 V 500 V 660/690 V kg (lb) kw kw kw kw kw kw A LE-K06kk 0.55 (.) Protected LE-K06kkA3 0.9 (.08). f 9 Sealed Protected Weight LE-K065kk 0.55 (.) LE-K065kkA3 0.9 (.08) LE-K09kk 0.55 (.) LE-K09kkA3 0.9 (.08) LE-K095kk 0.55 (.) Sealed LE-K095kkA3 0.9 (.08). f Protected LE-D09kk 0.55 (.) Sealed LE-D093kk 0.9 (.08) Protected LE-Dkk 0.55 (.) Sealed LE-D3kk 0.9 (.08) Protected LE-D88kk (.93) Sealed LE-D85kk.05 (.38) Protected LE-D58kk (.93) Sealed LE-D55kk.05 (.38) Sealed LE-D35kk.3 (9.5) Sealed LE-D05kk.8 (0.66) Sealed LE-D505kk.85 (0.69) Sealed LE-D655kk.85 (0.69) Sealed LE-D805kk 5. (.33) Sealed LE-D955kk 5. (.993) Specifications Enclosure Control by pushbuttons mounted on enclosure cover LE-K06 and K09 Double insulated enclosure, IP 659, l: 80 mm Double insulated enclosure, IP 659, l: LE-K06kkkA3, LE-K09kkkA3 75 mm LE-D09 and D Double insulated enclosure, IP 659 LE-D8 and D5 Double insulated enclosure, IP 557 LE-D3 to D95 Metal enclosure, IP 559 LE-K06 and K09, LE-D09 to D95 green Start button I red Stop/Reset button O Connections LE-D09 to D95 Pre-wired power circuit connections a Coil selection LE-K Volts AC 50/60 Hz / /0 380/ / /690 Code J7 B7 C7 D7 E7 F7 FC7 M7 P7 U7 Q7 V7 N7 R7 S7 Y7 LE-D Volts AC 50/60 Hz 8 0 0/ / Code B7 D7 E7 F7 M7 P7 U7 Q7 V7 N7 R7 Other voltages: LE-K and LE-D please consult your Regional Sales Office Square D All Rights Reserved 7/98
121 Enclosed contactors LE-D Forms (mounted by Telemecanique) Description For use on Suffix to be added to starter reference a No pushbuttons on cover LE-D09 to D95 A0 blue Reset button R LE-D09 to D95 A05 3-position selector switch ( I - O - II ) ( I : Automatic Start; O : Stop; II : Manual start) blue Reset button R -position selector switch O - I ( O : Stop; I : Manual Start) blue Reset button "R Knock-outs for x 6P cable glands (instead of x 3P) green Start button I red Stop button O blue Reset button R Special device for control of compressor and vacuum valve (no-load starting). Maintained control. Limits the IP rating to only. neutral terminal Fitted as standard on starters ordered with 0 V (U7) control supply. LE-D09 and D LE-D09 and D LE-D09 and D LE-D09 and D LE-D09 to D5 LE-K06 and K09 LE-D09 to D95 A09 A3 A0 A35 A0 A59 Accessories (mounted by the customer) Description For use on Reference Start button latching device for stay-put operation (Start-Stop) Miniature control circuit fuse holder size 5 x 0 A/50 V Fuse supplied a Example: LE-D093F7A0. Weight kg (lb.) LE-D8 to D65 LA9-D (0.3) LE-D09 and D LA9-D (0.088) LE-D8 and D5 LA9-D (0.055) 0 V LE-D09 to D5 LA9-D (0.0) Pilot light with neon bulb red lens and locking ring 0 V LE-D09 to D5 LA9-D (0.0) 380, 5 V LE-D09 to D5 LA9-D (0.0) front-mounting block of auxiliary contacts LE-D09 to D95 LA-DNii (0.066) 7/ Square D All Rights Reserved
122 Enclosed contactors with fused disconnect switch LE-K and LE-D International applications only Contains UL listed, CSA certified, CE marked components. Assemblies are not UL listed or CSA certified. LE-K065kk LE-D096kk Standard power ratings of 3-phase motors 50/60 Hz in category AC-3 Operational current Fuses to be fitted by the customer Basic reference. Complete with code indicating control circuit voltage a 0/30 V 380/00 V 5 V 0 V 500 V 660/690 V 0 V up to Size Type am kw kw kw kw kw kw A A lb (kg) x 38 0 LE-K065kk.50 (3.97) LE-K095kk.50 (3.97). 9 0 x 38 LE-D096kk q.960 (.3) x 38 LE-D096kk.960 (.3) x 38 6 LE-D6kk.960 (.3) x 38 0 LE-D86kk.00 (.850) x 38 5 LE-D56kk.00 (.850) x 5 3 LE-D36kk 5.90 (.) x 5 0 LE-D06kk (.70) x LE-D506kk 6.0 (.98) x LE-D656kk (.705) x LE-D806kk f 7.00 (5.653) Specifications Enclosure Control by pushbuttons mounted on enclosure cover LE-K06, K09 Double insulated enclosure, IP 659 LE-D09 to D5 Double insulated enclosure, IP 557 LE-D3 to D80 Metal enclosure, IP 559 LE-K06, K09 LE-D09 to D65 No pushbuttons on cover LE-D80 Isolator with external operator Connections LE-K06, K09 LE-D09 to D5 LE-D3 to D80 LE-K06, K09 LE-D09 to D80 green Start button I red Stop/Reset button O 3-pole isolator 3-pole isolator + additional pole LA8-D5 3-pole isolator and circuit breaker GB-CB08 Pre-wired power and control circuit connections. Weight c Overload protection by thermal overload relay to be ordered separately. a Coil selection LE-K Volts AC 50/60 Hz / /0 380/ / /690 Code J7 B7 C7 D7 E7 F7 FC7 M7 P7 U7 Q7 V7 N7 R7 S7 Y7 LE-D Volts AC 50/60 Hz 8 0 0/ / Code B7 D7 E7 F7 M7 P7 U7 Q7 V7 N7 R7 Other voltages: LE-K and LE-D, please consult your Regional Sales Office. q Selected according to overall dimensions and number of operating cycles. f Supplied with 3 entries. LE-D06kk 998 Square D All Rights Reserved 7/98
123 Enclosed contactors with fused disconnect switch LE-K and LE-D International applications only Forms (mounted by Telemecanique) Description For use on Suffix to be added to starter reference a No pushbuttons on cover LE-D09 to D65 A0 blue Reset button R LE-D09 to D80 A05 Special device for control of compressor and vacuum valve (no-load starting). Maintained control. Limits IP rating to only. neutral terminal. Fitted as standard on starters ordered with 0 V (U7) control supply. Accessories (mounted by the customer) LE-D09 to D5 LE-K06 and K09 LE-D09 to D80 A0 A59 Description For use on Catalog number Weight kg (lb.) Start button latching device for stay-put operation (Start-Stop) Miniature control circuit fuse holder size 5 x 0, A/50 V Fuse supplied LE-D09 to D65 LA9-D (0.35) LE-D09 to D5 LA9-D (0.056) Pilot light with neon bulb red lens and locking ring front-mounting block of auxiliary contacts 0 V LE-D09 to D5 LA9-D (0.05) 0 V LE-D09 to D5 LA9-D (0.05) 380, 5 V LE-D09 to D5 LA9-D (0.05) LE-D09 to D95 LA-DNkk (0.067) a Example: LE-D096F7A0. 7/ Square D All Rights Reserved 3
124 Enclosed starters LE-D International applications only Contains UL listed, CSA certified, CE marked components. Assemblies are not UL listed or CSA certified LE-D3 Operational current up to Minimum c.s.a. of phase conductors Fuses to be fitted separately For use with relay LR-D or kit LA9-D (to be ordered separately) Basic reference. Complete with code indicating control circuit voltage a am gi A mm A A kg (lb.) LA9-D75 f LE-D3kk 0.90 (.06) LR-D3 q LE-D3kk 0.90 (.06).5 5 LR-D3 q LE-D55kk.05 (.78) LA9-D0975 f LE-D55kk.05 (.78) LE-D05kkA0 t.80 ( LR-D3359 q LE-D05kk.80 (0.86) LE-D655kkA0 t.850 (0.883) LR-D3363 q LE-D655kk.850 ( LR-D3365 q LE-D805kk 5.0 (.53) LE-D805kkA0 t 5.0 (.53) Specifications Enclosure LE-D Double insulated, degree of protection IP 659 LE-D5 Double insulated, degree of protection IP 557 LE-D0 to D80 Metal, degree of protection IP 559 Control ( pushbuttons mounted on enclosure cover) No pushbuttons on cover LE-D to D80 green Start button I red Stop/Reset button O Weight LE-DkkkkkA0 Connections LE-D to D80 Pre-wired control circuit connections c 3-phase 0/30 V or 380/00 V or 5 V 50/60 Hz. 3-core or 3 + N (unprotected neutral) insulated PVC cable, fixed to walls, in cable racks or ducting, laid singly, ambient temperature 95 F ( 35 C), conforming to NF C a Control circuit voltage 0/30 V 50/60 Hz (code M7) or 380/00 V (code Q7). q Order the required LR-D thermal overload relay separately. For use on balanced circuits only. f As protection is provided by type gi fuses only, the Stop function normally provided by the thermal overload relay (where am type fuses are used) can be obtained by means of kit LA9-Dkk75. t Equipment supplied without pushbuttons; external Start-Stop station required. LE-D Square D All Rights Reserved 7/98
125 Enclosed starters LE-D International applications only Contains UL listed, CSA certified, CE marked components. Assemblies are not UL listed or CSA certified. Forms (mounted by Telemecanique) Description For use on Suffix to be added to the reference q No pushbuttons on cover LE-D & D5 A0 blue Reset button R LE-D to D80 A05 green Start button I and red Stop button "O with N.C. contact (for distribution circuits without thermal overload relay) -position selector switch "O-I ("O : Stop ; "I : Manual Start) blue Reset button "R Knock-outs for x 6 mm plastic cable glands (instead of x 3 plastic glands) LE-D & D5 LE-D LE-D A07 A3 A0 neutral terminal (3-phase + N circuits) LE-D to D80 A59 Accessories (mounted by the customer) Description For use on Unit reference Weight kg (lb.) Start button latching device for stay put operation (Start-Stop) LE-D5 to D65 LA9-D (0.3) Kits to provide stop function without thermal overload relay fitted Miniature control circuit fuse holder size 5 x 0 A /50 V Fuse supplied Pilot light with neon bulb, red lens and locking ring front-mounting block of auxiliary contacts (see page????) LE-D LA9-D (0.088) LE-D5 LA9-D (0.0) LE-D LA9-D (0.088) LE-D5 LA9-D (0.055) 0 V LE-D & D5 LA9-D (0.0) 0 V LE-D & D5 LA9-D (0.0) 380, 5 V LE-D & D5 LA9-D (0.0) LE-D to D80 LA-DNkk (0.066) c 3-phase 0/30 V or 380/00 V 50/60 Hz. 3-core or 3 + N (unprotected neutral) insulated PVC cable, fixed to walls, in cable racks or ducting, laid singly, ambient temperature 95 F (35 C), conforming to NF C a Order LR-D thermal overload relay separately. For use on balanced circuits only. q Example: LE-D3M7A0. 7/ Square D All Rights Reserved 5
126 Enclosed starters with fused disconnect switch LE-D International applications only Contains UL listed, CSA certified, CE marked components. Assemblies are not UL listed or CSA certified. LE-D6kk Operational Minimum c.s.a. Fuses to be fitted by customer For use with relay LR- Basic reference. Weight current up to of phase D or kit LA9-D (to be Complete with code conductors Size Type ordered separately) indicating control circuit am gi voltage a A mm A A kg (lb.) x 38 6 LA9-D0975 f LE-D6kk.960 (.3) x 38 0 LR-D3 q LE-D6kk.960 (.3) x 38 0 LA9-D0975 f LE-D56kk.00 (.850).5 0 x 38 5 LR-D3 q LE-D56kk.00 (.850) 0 0 x 5 0 LE-D06kkA0 t (.70) 5 0 x 5 50 LR-D3357 q LE-D06kk (.70) 63 6 x LE-D656kkA0 t (.70) 76 6 x LR-D3363 q LE-D656kk (.70) 90 5 x LR-D3365 q LE-D806kk t 7.00 (5.65) x LE-D806kk t 7.00 (5.65) Specifications Enclosure Control ( pushbuttons mounted on enclosure cover) No pushbuttons on cover LE-D and D5 Double insulated, degree of protection IP 557 LE-D0 to D80 Metal, degree of protection IP 559 LE-D to D65 LE-DkkkkkA0 LE-D80 green Start button I red Stop/Reset button O Isolator with LE-D and D5 3-pole isolator + additional pole LA8-D5 external operator LE-D0 to D80 3-pole isolator + circuit breaker GB-CB08 Connections LE-D to D80 Pre-wired power and control circuit connections c 3-phase 0/30 V or 380/00 V 50/60 Hz. 3-core or 3 + N (unprotected neutral) insulated PVC cable, fixed to walls, ceilings, in cable racks or ducting, laid singly, ambient temperature 95 F (35 C), conforming to NF C a Control circuit voltage 0/30 V 50/60 Hz (code M7) or 380/00 V (code Q7). q Order the required LR-D thermal overload relay separately. For use on balanced circuits only. f As protection is provided by type gi fuses only, the Stop function normally provided by the thermal overload relay (where am type fuses are used) can be obtained by means of kit LA9-D0975. t Equipment supplied without pushbuttons; external Start-Stop station required. LE-D Square D All Rights Reserved 7/98
127 Enclosed starters with fused disconnect switch LE-D International applications only Forms (mounted by Telemecanique) Description For use on Suffix to be added to reference q No pushbuttons on cover LE-D & D5 A0 blue Reset button R LE-D to D80 A05 green Start button I and red Stop button O with N.C. contact (for distribution circuits without thermal overload relay) LE-D & D5 A07 neutral terminal (for 3-phase + N circuits) LE-D to D80 A59 Accessories (mounted by the customer) Description Start button latching device for stay put operation (Start-Stop) Kit to provide Stop function without thermal overload relay fitted Miniature control circuit fuse holder size 5 x 0, A/50 V Fuse supplied Pilot light with neon bulb, red lens and locking ring front-mounting block of auxiliary contacts (see page????) For use on Reference Weight kg (lb.) LE-D to D65 LA9-D (0.3) LE-D & D5 LA9-D (0.0) LE-D & D5 LA9-D (0.055) 0 V LE-D & D5 LA9-D (0.0) 0 V LE-D & D5 LA9-D (0.0) 380, 5 V LE-D & D5 LA9-D (0.0) LE-D to D80 LA-DNkk (0.066) c 3-phase 0/30 V or 380/00 V 50/60 Hz. 3-core or 3 + N (unprotected neutral) insulated PVC cable, fixed to walls, in cable racks or ducting, laid singly, ambient temperature 95 F (35 C), conforming to NF C a Order the required LR-D thermal overload relay separately. For use on balanced circuits only q Example: LE-D6M7A0. 7/ Square D All Rights Reserved 7
128 Enclosed reversing starters LE-D International applications only Contains UL listed, CSA certified, CE marked components. Assemblies are not UL listed or CSA certified. LE-K065 Standard power ratings of 3-phase motors 50/60 Hz in category AC-3 0 V 30 V 380 V 00 V 5 V 0 V 500 V 660 V 690 V Operational current 0 V up to Basic reference. Complete with code indicating control circuit voltage a kw kw kw kw kw kw A kg (lb.) LE-K065kk.080 (.38). 9 LE-K095kk.080 (.38) or LE-D095kk q.00 (.630) LE-D095kk.00 (.630) LE-D5kk.00 (.630) LE-D85kk.0 (5.33) LE-D55kk.570 (5.666) LE-D35kk.00 (9.039) LE-D05kk 5.70 (.68) LE-D505kk 5.70 (.059) LE-D655kk 5.70 (.059) LE-D805kk (.77) LE-D955kk (5.3) Specifications Enclosure LE-K065 and K095 Double insulated enclosure, IP 659 LE-D09 to D5 Double insulated enclosure, IP 557 LE-D3 to D95 Metal enclosure, IP 559 Control by operator mounted on enclosure cover LE-D09 to D95 blue Reset button R Connections LE-D09 to D95 Pre-wired power and control circuit connections Weight Forms (mounted by Telemecanique) Description For use on Suffix to be added to starter reference t No pushbuttons on cover LE-D09 to D95 A0 blue Reset button R LE-K06 and K09 A05 LE-D095 green Start button I green Start button II red Stop/Reset button O LE-D09 to D95 A neutral terminal Fitted as standard on starters ordered with 0 V (U7) control supply LE-K06 and K09 LE-D09 to D95 A59 c Overload protection by thermal overload relay, to be ordered separately. a Coil selection LE8-K Volts AC 50/60 Hz / /0 380/ / /690 Code J7 B7 C7 D7 E7 F7 FC7 M7 P7 U7 Q7 V7 N7 R7 S7 Y7 LE-D Volts AC 50/60 Hz 8 0 0/ / Code B7 D7 E7 F7 M7 P7 U7 Q7 V7 N7 R7 LE-D Square D All Rights Reserved 7/98
129 D-Line Contactors, Overload Relays and Accessories Enclosed reversing starters with fused disconnect switch LE-D International applications only Contains UL listed, CSA certified, CE marked components. Assemblies are not UL listed or CSA certified. LE-D096 Standard power ratings of 3-phase motors 50/60Hz in category AC-3 0 V 30 V 380 V 00 V 5 V 0 V 500 V 660 V 690 V Operational current 0 V up to Fuses to be fitted by the customer Size Type am Basic reference. Complete with code indicating control circuit voltage a kw kw kw kw kw kw A A kg (lb.) x 38 0 LE8-K065kk.60 (3.57) LE8-K095kk.60 (3.57). 9 0 x 38 or LE-D096kkq 3.55 (7.86) x 38 LE-D096kk 3.55 (7.86) x 38 6 LE-D6kk 3.55 (7.86) x 38 0 LE-D86kk 3.70 (8.57) x 38 5 LE-D56kk.67 (0.95) x 5 3 LE-D36kk 5.80 (.787) x 5 0 LE-D06kk.7 (3.) x LE-D506kk.70 (3.) x LE-D656kk.77 (3.56) x LE-D806kk 6.00 (35.7) Specifications LE8-K065 and K095 Double insulated enclosure, IP 659 Enclosure LE-D09 to D80 Metal enclosure, IP 559 Control by operator mounted on enclosure cover LE-D09 to D5 blue Reset button R No pushbuttons on cover LE-D3 to D80 Isolator with external operator Connections LE-D09 to D5 LE-D3 to D80 LE8-K06, K09 LE-D09 to D80 Weight 3-pole isolator + additional pole LA8-D5 3-pole isolator and circuit breaker GB-CB08 Pre-wired power and control circuit connections Forms (mounted by Telemecanique) Description For use on Suffix to be added to starter reference f No pushbuttons on cover LE-D09 to D5 A0 blue Reset button R green Start button I green Start button II red Stop/Reset button O neutral terminal. Fitted as standard on starters ordered with 0 V (U7) control supply. LE8-K06 and K09. LE-D3 to D80 LE-D09 to D80 LE8-K06, K09 LE-D09 to D80 A05 A A59 c Overload protection by thermal overload relay, to be ordered separately. a Standard control circuit voltages, see page 30. f Example: LE-D096F7A0. LE-D06 7/ Square D All Rights Reserved 9
130 D-Line Contactors, Overload Relays and Accessories Wye-Delta starters LE3-D International applications only Wiring methods differ from typical North American practice. Contains UL listed, CSA certified, CE marked components. Assemblies are not UL listed or CSA certified. LE3-D095 Standard power ratings of squirrel cage motors q Mains voltages - delta connection 0 V 380 V 5 V 0 V Basic reference. Complete with code indicating control circuit voltage a Weight kw kw kw kw kg (lb.) Maximum operating rate in starts/hour: LE3-K: and LE3-D: 30. Maximum starting time: 30 seconds LE3-K065kk.60 (3.9) LE3-K095kk.60 (3.9) or LE3-D095kk f (8.07) 5.5 LE3-D5kk (8.07) 8.5 LE3-D85kk (8.67) LE3-D35kk 5.60 (.376) LE3-D05kk 8.60 (7.989) LE3-D505kk 8.50 (7.967) LE3-D805kk.000 (30.86) Specifications Enclosure LE3-D09 to D80 Metal, degree of protection IP 559 Control ( pushbuttons mounted on enclosure cover) LE3-D09 to D8 green Start button I red Stop/Reset button O No pushbuttons on cover LE3-D3 to D80 LE3-K06 and K09 Connections LE3-D09 to D80 A timer LA-DS imposes a delay of 0 ms ± 5 ms on the delta contactor at the moment of changeover to ensure that the star contactor has sufficient breaking time. Forms (mounted by Telemecanique) Pre-wired power and control circuit connections Description For use on Suffix to be added to starter reference t No pushbuttons on cover LE3-D09 to D8 A0 blue Reset button R LE3-D09 to D80 A05 green Start button I red Stop/Reset button O Neutral terminal Fitted as standard on starters ordered with 0 V (U7) control supply LE3-D3 to D80 LE3-K06 and K09 LE3-D09 to D80 A06 A59 c Overload protection by means of thermal overload relay to be ordered separately. Select appropriate overload relay for setting at 0.58 the full load rated motor current. a Coil selection LE3-K Volts AC 50/60 Hz / /0 380/ / /690 Code J7 B7 C7 D7 E7 F7 FC7 M7 P7 U7 Q7 V7 N7 R7 S7 Y7 LE3-D Volts AC 50/60 Hz 8 0 0/ / Code B7 D7 E7 F7 M7 P7 U7 Q7 V7 N7 R7 t Example: LE3-D095F7A Square D All Rights Reserved 7/98
131 D-Line Contactors, Overload Relays and Accessories Star-Delta starters with fused disconnect switch LE3-D International applications only Wiring methods differ from typical North American practice. Contains UL listed, CSA certified, CE marked components. Assemblies are not UL listed or CSA certified. LE3-D096 Standard power ratings of squirrel cage motors q Mains voltages - delta connection 0 V 380 V 5 V 0 V Size Fuses to be fitted by customer Type am Basic reference. Complete with code indicating control circuit voltage a kw kw kw kw A kg (lb.) Maximum operating rate: 30 starts/hour. Maximum starting time: 30 seconds x 38 0 LE3-D096kk (8.598) x 38 5 LE3-D6kk (8.598) 8.5 x 5 0 LE3-D86kk.850 (0.69) x LE3-D36kk (6.865) x LE3-D06kk 6.90 (37.56) x 58 5 LE3-D506kk 7.00 (37.78) LE3-D806kk 7.50 (60.66) Specifications Enclosure LE3-D09 to D80 Metal enclosure, degree of protection IP 559 Control ( pushbuttons on enclosure cover) LE3-D09 and D No pushbuttons on cover LE3-D8 to D80 Isolator with external operator LE3-D09 and D green Start button l red Stop/Reset button O 3-pole isolator + additional pole LA8-D5 LE3-D8 tp D80 3-pole isolator and circuit breaker GB-CB08 Connections LE3-D09 to D80 Pre-wired power and control circuit connections A timer LA-DS imposes a delay of 0 ms ± 5 ms on the delta contactor at the moment of changeover to ensure that the star contactor has sufficient breaking time. Weight Forms (mounted by Telemecanique) Description For use on Suffix to be added to starter reference f No pushbuttons on cover LE3-D09 and D A0 blue Reset button R LE3-D09 to D80 A05 green Start button I red Stop/Reset button O neutral terminal Fitted as standard on starters ordered with 0 V (U7) control supply. LE3-D8 to D80 LE3-D09 to D80 A06 A59 c Overload protection by thermal overload relay, to be ordered separately. Select appropriate overload relay for setting at 0.58 the full load rated motor current. a Coil selection Volts 8 0 0/ / /60 Hz B7 D7 E7 F7 M7 P7 U7 Q7 V7 N7 R7 Other voltages: see replacement coil pages 07/ to 07/7. f Example: LE3-D096F7A0. LE3-D06 7/ Square D All Rights Reserved 3
132 D-Line Contactors, Overload Relays and Accessories Spare parts and accessories International applications only Operating heads for Start and Stop/Reset pushbuttons Description For use on Unit reference Weight kg (lb.) LE-D09 and D ZA-BA33 c 0.05 (0.033) LE-D8 LA9-D (0.033) ZA-BA33 ZA-BL3 Flush green I Projecting red O Mounting kit for heads ZA-BA33 and ZA-BL3 Operating heads for Reset pushbuttons LE-D5 LA9-D (0.033) LE-D09, D and D5 LA9-D (0.033) LE-D8 LA9-D (0.033) LE-D09 and D ZA-BL3 c 0.00 (0.0) LE-D8 LA9-D (0.0) LE-D5 LA9-D (0.0) LE-D09 and D LA9-D (0.0) LE-D8 LA9-D (0.0) LE-D5 LA9-D (0.0) LE-D09 and D LA9-D (0.088) LE-D09 and D ZA-BA639 a 0.05 (0.033) LE-D8 LA9-D (0.033) LA9-D098 Flush blue R LE-D5 LE-D095 and D5 LE-D09 and D LE-D85 LE-D8 LE-D55 LA9-D (0.033) LA9-D (0.033) LA9-D (0.033) LE-D5 LA9-D (0.033) Mounting kit for head ZA-BA639 LE-D09 and D LA9-D (0.033) Contact blocks LE-D09 and D LA9-E0906 q 0.05 (0.033) LA9-D0906 LA9-D09906 N.O. spring return LE-D095 and D5 LE-D09 and D LE-D8 and D5 LE-D85 and D55 LE-D8 and D5 LA9-D09906 f 0.05 (0.033) LA9-D6906 q 0.05 (0.033) LE-D09 and D LA9-E0975 t 0.05 (0.033) N.C. spring return LE-D5 LE-D09 to D5 LA9-D0975 t 0.00 (0.0) Contact block support LE-D09 and D LA9-D (0.033) Accessories Start pushbutton latching device for local stay put operation LE-D8 and D5 LE-D8 and D5 LA9-D (0.055) Shim LE-D8 LA9-D (0.0) Enclosure sealing kit LE-D09 and D LA9-E (0.0) LE-D8 and D5 LE-D095 to D55 LE-D09 to D5 DE-DS (0.0) Vacuum valve (sold in lots of 5) LE and LE-D09 to D5 LA9-D (0.0) c Remember to order mounting kit LA9-D090 ( kit only required for both heads). a Remember to order mounting kit LA9-D0935. q Color reference green. f Color reference black. t Color reference red. LA9-D Square D All Rights Reserved 7/98
133 International applications only D-Line Contactors, Overload Relays and Accessories Spare parts and accessories Empty enclosures for across-the-line starters without off-load isolator For use with Type c Pushbutton operating head(s) or blanking plug(s) mounted on the cover Reference Weight kg (lb.) Without a DE-DS5A0 f 0.30 (0.98) DE-DS53A06 LE-D09, D LE-D88 q LE-D58 LE-D093, D3 LE-D85 q LE-D55 Double insulated degree of protection IP 9 Double insulated degree of protection IP 7 Double insulated degree of protection IP 659 Double insulated degree of protection IP 557 flush blue head R DE-DS5A05 f 0.30 (0.98) flush green head I projecting red head O DE-DS5A06 f 0.30 (0.98) blanking plugs (select or heads from previous page if required) DE-DS68A (.90) Without a DE-DS53A0 f 0.30 (0.98) flush blue head R DE-DS53A05 f 0.30 (0.98) flush green head I projecting red head O DE-DS53A06 f 0.30 (0.98) blanking plugs (select or heads from previous page if required) Empty enclosures for D.O.L. starters with off-load isolator DE-DS65A (.90) blanking plugs DE-DS56A0.330 (.93) DE-DS65A0 LE-D096, D6 LE-D86, D56 Double insulated degree of protection IP 557 Double insulated degree of protection IP 557 flush blue head R blanking plug flush green head I projecting red head O blanking plugs (select or heads from previous page if required) Empty enclosures for reversing starters without off-load isolator DE-DS56A (.93) DE-DS56A (.93) DE-DS66A0.30 (3.5) blanking plugs DE-DS55A0.330 (.93) LE-D095, D5 Double insulated degree of protection IP 557 flush blue head R blanking plug flush green head I flush green head II projecting red head O DE-DS55A (.93) DE-DS55A.330 (.93) LE-D85, D55 Double insulated degree of protection IP 557 blanking plugs (can be fitted with flush blue head R selected from previous page) DE-DS65A0.30 (3.5) DE-DS56A05 c Dimensions and knock-outs for cable glands: see pages 3 to 37. a Cover can be supplied with cut-outs for fitting, or 3 operating heads, see page 3. q Order shim LA9-D83 separately: see page 3. f Variant: to order an enclosure with knock-outs for 6 mm plastic cable glands, add suffix A0 to the reference. Example : DE-DS53A06A0. DE-DS55A 7/ Square D All Rights Reserved 33
134 D-Line Contactors, Overload Relays and Accessories Dimensions LEkD: International applications only Enclosed D-Line starters without Fused Disconnect Switch LE-D093, D3 LE-D09, D LE-D85, D55 LE-D88, D58 LE-D35, D05, D505, D655 LE3-D095, D5, D85 xø5.5 xø = = 88 = 50 = = = 0 = 65 = 50 6 () 3 xø7.7 = 05 = 8 = 95 = () 50 for LE-DkkkkkA0 (without pushbuttons). LE-D095, D5, D85, D55 xø5.5 LE-D805, D955 LE-D35, D05, D505, D655 LE3-D35 LE-D805, D955 LE3-D05, D505 c c 80 = = = 60 = 65 c 307 xø7.7 = = = 65 = 65 c 307 xø7.7 = = = 65 = LE- c c c Note: Dimensions are expressed in millimeters. D LE-Dkkk 76 ( pushbuttons I and O ) (mm X.039 = inches) D LE-DkkkkkA0 65 (without pushbuttons) D85 7 LE-Dkkk 69 ( reset pushbutton R ) D55 7 LE3-Dkkk 65 (without pushbuttons) () 90 for LE3-Dkkk (without pushbuttons). LE3-D805 Knock-outs or blanking plugs for cable glands (gland size in mm, P = Plastic) = 35 = Type of enclosure At top At bottom LE-D093, D09 LE-D3, D LE-D095, D5 x 3 P x 3 P 00 () = LE-D85, D88 LE-D55, D58 LE-D85, D55 x 3 P and x 6 P x 6 P LE-D35, D05 x 3 P and x P x 3 P and x P LE-D35 to D655 LE-D505, D655 x 3 P and x 9 P x 3 P and x 9P xm8x5 LE-D805, D955 LE-D805, D955 x 3 P and x 36 P x 3 P and x 36P = LE3-D095, D5 x 6 P and x 3 P x 6 P and x 3P LE3-D85 x P and x 3 P x P and x 6P LE3-D35 LE3-D05 x P x 9 P x P, x 3 P and x 6 P x 9 P, x 3 P and x P LE3-D505 x 36 P x 36 P, x 3 P and x 9 P LE3-D805 x 36 P x 3 P and 3 x 36 P () + mm with blanking plugs Square D All Rights Reserved 7/98
135 D-Line Contactors, Overload Relays and Accessories Dimensions LEkD: International applications only Enclosed D-Line starters with Fused Disconnect Switch LE-D096, D6, D86, D56 xø5.5 LE-D096, D6, D86 LE3-D096, D6 c c 80 = = = 60 = () 3 = xø = 8 95 = = 3 LE- c c () 5 for LE-Dkkk ( reset pushbutton R ). D09, D 3 39 D8, D5 5 LE-D56, D36 LE3-D86, D36 LE-D36, D06, D506, D656 b xø7.7 H = b xø7.7 H = = c c () = G a = = 3 c c () = G a = 3 LE- a b c c G H LE3- a b c c G H LE- a b c c G H D D D D06, 506, D D () c = c for LE3-Dkkk (without pushbuttons). () c = c for LE-Dkkkkkk A0 (without pushbuttons). LE-D06, D506, D656, D806 LE3-D06, D506, D806 LE-D806 = a-75 = 3 Knock-outs or blanking plugs for cable glands (gland size in mm, P = Plastic) Type of At top enclosure At bottom b () b+57.5 b-50 xm8x5 b-75 = LE-D096, D6 x 3 P x 3 P LE-D86, D56 x 3 P and x 6 P x 6 P LE-D096 to D56 x 3 P and x 6 P x 3 P and x 6 P LE-D36, D06 LE-D36, D06 x 3 P and x P x 3 P and x P LE-D506, D656 LE-D506, D656 x 3 P and x 9 P x 3 P and x 9 P = LE-D806 LE-D806 x 3 P and x 36 P x 3 P and x 36 P c c a-50 a a+57.5 LE3-D096, D6 x 3 P and x 6 P x 3 P and x 6 P LE3-D86, D36 x P x 3 P, x 6 P and x P () + mm with blanking plugs. LE3-D06 x 9 P x 3 P, x P and x 9 P LE- a b () c c LE3-D506 x 36 P x 3 P, x 9 P and x 36 P D06, D506, D LE3-D806 x 36 P x 3 P and 3 x 36 P D Note: Dimensions are expressed in millimeters. LE3- D06, D (mm X.039 = inches) D LE- D / Square D All Rights Reserved 35
136 D-Line Contactors, Overload Relays and Accessories Dimensions LEkK: International applications only Enclosed K-Line starters without Fused Disconnect Switch LE-K06, K09 (except A3) xø5.3 LE-K06kkkA3, K09kkkA3 LE-K06, K09 LE3-K06, K xø = 80 = () () For LE Enclosed K-Line starters with Fused Disconnect Switch LE-K06, K09 LE8-K06, K xø () () For LE8 Note: Dimensions are expressed in millimeters. Knock-outs or blanking plugs for cable glands (gland size in mm, P = Plastic) (mm X.039 = inches) Type of enclosure At top At bottom LE-K x 3 P x 3 P LE-KkkA3 x 3 P and x 6 P x 3 P and x 6 P LE-K x 3 P and x 6 P x 3 P and x 6 P LE3 x 3 P and x 6 P x 3 P and x 6 P LE, LE8-K x 3 P and x 6 P x 3 P and x 6 P Square D All Rights Reserved 7/98
137 LG-K and LG-D: International applications only Starters without isolator D-Line Contactors, Overload Relays and Accessories Dimensions LG-K06, K09 LG-D, D8 LG7-K06, K09, D, D8 LG8-K06, K09, K 0 xø5.3 () xø () (3) Knock-outs or blanking plugs for cable glands () Emergency stop for starters < 3 kw Type of enclosure At top At bottom () Emergency stop for starters 3 kw LG-K and LG-D x 3 P and x 6 P x 3 P and x 6 P (3) Only for LG7 LG7-K and LG7-D x 3 P and x 6 P x 3 P and x 6 P LG8-K x 3 P and x 6 P x 3 P and x 6 P Note: Dimensions are expressed in millimeters. (mm X.039 = inches) 7/ Square D All Rights Reserved 37
138 D-Line Contactors, Overload Relays and Accessories Wiring diagrams LE-K and LE-D: International applications only Enclosed non-reversing K-Line starters LE-K06, K09 LE-K06kkkA3, K09kkkA3 LE-K06, K09 LE-K06kkkA3, K09kkkA3 L L 3 L3 5 Q/ KM/5 KM I 3 KM O KM I U V 6 W N KM/5 O KM A A N KM/ KM A A Enclosed non-reversing D-Line starters LE-D09 to D95 LE-DkkkkkA0 LE-D09 and D LE-D8 to D95 LE-DkkkkkA0, LE-DkkkkkA05 KM /L 3/L U V 3 W /L3 KM/5 I N KM/ 3 O KM KM A 3 A KM/5 l N KM/ 8 7 O KM KM A 3 A KM/5 N l O KM KM A 3 KM/ A Square D All Rights Reserved 7/98
139 LE-K and LE-D: International applications only Enclosed reversing K-Line starters D-Line Contactors, Overload Relays and Accessories Wiring diagrams LE-K06, K09 LE-K06, K09 Variant A05 L L L3 KM/5 KM/5 O 95 R KM KM KM KM 5 5 KM KM KM KM 96 Remote Control 3 5 () () () () U V 6 W N KM/ KM A A A A KM N KM/ KM A A A A KM Enclosed reversing D-Line starters LE-D095 to D55 () For the addition of end of travel limit switches, with automatic stopping in either direction: remove the connections /KM to A/KM and /KM to A/KM LE-D35 to D955 L L L3 KM/5 R 95 L L L3 KM/5 R KM KM l 3 O KM 5 53 l l KM KM KM l 3 O 3 (53) KM (5) l l 3 3 (53) KM (5) 3 5 KM KM U V 6 W KM KM U V 6 W N KM/ KM A A A A KM N KM/ KM A A A A KM ( ) for LE-D3 7/ Square D All Rights Reserved 39
140 D-Line Contactors, Overload Relays and Accessories Wiring diagrams LE-K, LE-D, LE8-K and LE-D: International applications only Across-the-line starters and starters for the control of distribution circuits LE-K06, K09 LE-D09 to D80 LE-DkkkkkA0 Q KM /L U 3/L 3 3 V 5/L W LE-K06, K09 LE-D09 to D5 LE-D3 to D65 LE-D80 LE-DkkkkkA0, DkkkkkA05 Q/ N KM/5 O I KM A A KM Q/ 0 Q N Q/6 l O Q KM KM A A Q/ N Q/6 l 8 7 F O Q KM KM A A Q/ N Q/ F 3 Q l O KM A A KM 3 Reversing starters LE8-K06, K09 LE8-K06, K09 Variant A05 KM/5 KM/5 L L L3 3 Q R 95 Q 3 5 O Remote Control KM KM KM 53 KM U 3 V W N KM/ KM KM KM A A () A A () KM N KM/ KM KM () () A A KM KM A A () For the addition of end of travel limit switches, with automatic stopping in either direction: remove the connections /KM to A/KM and /KM to A/KM LE-D096 to D806 LE-D096 to D56 LE-D36 to D806 Q /L 3/L 5/L3 Q/ F 3 Q 95 Q/ F 3 Q KM 6 6 KM 3 5 (5) (5) 6 96 O l 3 l l 3 KM 3 (53) KM (5) (5) 96 O l 3 l l 3 3 (53) KM 3 (53) KM 3 (53) 6 KM KM KM KM U V W N KM A A KM N KM A A KM Q/6 A A Q/6 A A ( ) for LE-D Square D All Rights Reserved 7/98
141 LG-K, LG-D, LG7-K, LG7-D, LG8-K: International applications only Across-the-line starters D-Line Contactors, Overload Relays and Accessories Wiring diagrams LG-K06, K09, D, D8 LG-K06, K09, D, D8 380/00 V, code Q7 or 00/5 V, code N7 0/30 V, code M7 L3/L L/L L/L3 Ph Q KM/ T3 T 3 T 5 3 KM S 6 3 Q S KM KM/5 KM A A U V W N M 3 c LG7-K06 LG7-K09, D, D8 LG7-K06, K09, D, D8 380/00 V, code Q7 or 00/5 V, code N7 0/30 V, code M7 /L 3/L 5/L3 /L 3/L 5/L3 D D Ph KM/ Q Q 3 KM S 3 6 KM U 3 5 V 6 F KM W 6 M 3 c U V W M 3 c E E S A KM KM/5 N A Reversing starters LG8-K06 LG8-K09, K LG8-K06, K09, K 380/00 V, code Q7 or 00/5 V, code N7 0/30 V, code M7 /L 3/L 5/L3 /L 3/L 5/L3 D D Ph KM/5 Q Q S 6 KM KM KM KM E E KM KM S KM KM A A S 53 U V 0 W M 3 c U V W M 3 c KM KM/ N A A KM 7/ Square D All Rights Reserved
142 D-Line Contactors, Overload Relays and Accessories Contactors -Definitions and comments Altitude Ambient air temperature Rated operational current (Ie) Rated conventional thermal current (Ith) c Permissible short time rating Rated operational voltage (Ue) Rated control circuit voltage (Uc) Rated insulation voltage (Ui) Rated impulse withstand voltage (Uimp) Rated operational power (expressed in kw) Rated breaking capacity a Rated making capacity a On-load factor (m) Pole impedance Electrical durability Mechanical durability The low oxygen atmosphere at high altitudes reduces the dielectric strength of the air and hence the rated operational voltage of the contactor. It also reduces the cooling effect of the air and hence the rated operational current of the contactor (unless the temperature drops at the same time). No derating is necessary up to 3000 m. Derating factors to be applied above this altitude for main pole operational voltage and current (AC supply) are as follows. Altitude 3500 m 000 m 500 m 5000 m Rated operational voltage Rated operational current The temperature of the air surrounding the device, measured near to the device. The operating characteristics are given: - with no restriction for temperatures between -5 and +55 C - with restrictions, if necessary, for temperatures between -50 and +70 C This is defined taking into account the rated operational voltage, operating rate and duty, utilization category and ambient temperature around the device. The current which a closed contactor can sustain for a minimum of 8 hours without its temperature rise exceeding the limits given in the standards. The current which a closed contactor can sustain for a short time after a period of no load, without dangerous overheating. This is the voltage value which, in conjunction with the rated operational current, determines the use of the contactor or starter, and on which the corresponding tests and the utilization category are based. For 3-phase circuits it is expressed as the voltage between phases. Apart from exceptional cases such as rotor short-circuiting, the rated operational voltage Ue is less than or equal to the rated insulation voltage Ui. The rated value of the control circuit voltage, on which the operating characteristics are based. For AC applications, the values are given for a near sinusoidal wave form (less than 5% total harmonic distortion). This is the voltage value used to define the insulation characteristics of a device and referred to in dielectric tests determining leakage paths and creepage distances. As the specifications are not identical for all standards, the rated value given for each of them is not necessarily the same. The peak value of a voltage surge which the device is able to withstand without breaking down. The rated power of the standard motor which can be switched by the contactor, at the stated operational voltage. This is the current value which the contactor can break in accordance with the breaking conditions specified in the IEC standard. This is the current value which the contactor can make in accordance with the making conditions specified in the IEC standard. This is the ratio between the time the current flows (t) and the duration of the cycle (T) m = t T Cycle duration: duration of current flow + time at zero current The impedance of one pole is the sum of the impedance of all the circuit components between the input terminal and the output terminal. The impedance comprises a resistive component (R) and an inductive component (X=Lω). The total impedance therefore depends on the frequency and is normally given for 50 Hz. This average value is given for the pole at its rated operational current. This is the average number of on-load operating cycles which the main pole contacts can perform without maintenance. The electrical durability depends on the utilization category, the rated operational current and the rated operational voltage. This is the average number of on-load operating cycles (i.e. with zero current flow through the main poles) which the contactor can perform without mechanical failure c Conventional thermal current, in free air, conforming to IEC standards. a For AC applications, the breaking and making capacities are expressed by the rms value of the symmetrical component of the short-circuit current. Taking into account the maximum asymmetry which may exist in the circuit, the contacts therefore have to withstand a peak asymmetrical current which may be twice the rms symmetrical component. NOTE: these definitions are extracted from standard IEC 97-. t T 998 Square D All Rights Reserved 7/98
143 D-Line Contactors, Overload Relays and Accessories Contactors -Definitions and comments 7/ Square D All Rights Reserved 3
144 and are registered trademarks of Underwriters Laboratories, Inc. is a registered trademark of Canadian Standards Association FINGERSAFE is a trademark of Square D Company Square D Company 800 Hwy. 6 East Knightdale, NC 755 (99) Seriplex is a trademark of Square D Company Square D and are registered trademarks of Square D Company. Catalog No. 850CT970 July Square D All Rights Reserved.
LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil
Product data sheet Characteristics LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 -
AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101403D0201 24/03/11 AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF09(Z) contactors are used for controlling power circuits
NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101433D0201 28/03/11 NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits.
Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information
Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC
Electronic overload relay EF65, EF96 and EF146
Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays.
IEC style contactors - long electrical and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide
- long al and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide range coils +0% to -30% Finger safe terminals Four-pole versions available NO + NC and
Electronic overload relay EF19 and EF45
Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor
SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original
SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original A motor starter is a combination of devices to allow an induction motor to start, run and stop according
RM4TG20 three-phase network control relay RM4-T - range 200..500 V
Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking
Technical catalogue. Modular DIN rail components Installation contactors
Technical catalogue Modular DIN rail components Installation contactors Installation Contactors Overview... ESB Installation Contactors 0 A / AC-/AC-7a ESB0...4 4 A / AC-/AC-7a ESB4...5 40 A / AC-/AC-7a
Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830
Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830 Ordering information Rated operational current AC 3 400 V I e A 50 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase
US Breaker Brand 3 Pole AC Contactors (Square D Telemecanique LC1 Replacements)
4 NC1 D09-D18 NC1 -D32 US Breaker Brand 3 Pole AC Contactors (Square D Telemecanique LC1 Replacements) Standards: UL508, CSA C22.2, IEC 60947, and CE Marked Integral DIN Rail & Base Mounting in One Compact
Type: DILM32 10(24V50HZ) Article No.: 277247
Type: DILM32 10(24V50HZ) Article No.: 277247 Ordering information Rated operational current AC 3 400 V I e A 32 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors,
Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear
Mini Motor Contactor J7KNA ) Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN-rail) Range from 4 to 5.5 (AC 3, 380/415V) 4 -main pole version (4 AC
PSR The compact range Description
Description The PSR range is the most compact of all the ABB softstarter ranges, thereby making it possible to fit many devices into the same enclosure. The system concept with Manual Motor Starters provides
Manual motor starter MS116
Data sheet Manual motor starter MS116 Manual motor starters are electromechanical devices for motor and circuit protection. These devices offer local motor disconnect means, manual ON/ OFF control, and
Bimetallic Overload Relay Specifications
Technical Data Bimetallic Overload Relay Specifications Bulletin Number 193K, 193T1 Topic Page Product Overview 2 Standards compliance and Certifications 2 General Specifications 193K 3 Approximate Dimensions
Catalog. Modular DIN rail components Installation contactors
Catalog Modular DIN rail components Installation contactors 0 CDC00C00 Installation contactors Benefits and features Overview Ordering details ESB installation contactors ESB0 ESB ESB0 ESB 7 EN installation
Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller
Overview/Modes of Operation Bulletin 150 Smart Motor Controller The SMC-3 is a compact, simple to use, solid-state motor controller designed to operate 3-phase motors. It features a built-in overload relay
Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only
Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description
Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display
Type: DILM9 10(24VDC) Article No.: 276705
Type: DILM9 10(24VDC) Article No.: 276705 Ordering information Rated operational current AC 3 400 V I e A 9 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors, 50
Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN 60204-1, VDE 0113 Part 1
MainswitchSurfacemounting Partno. P3-63/I4/SVB Articleno. 207343 CatalogNo. SP3-063-I4CRQ IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual
RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC
Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage
Bulletin 150 SMC Flex Smart Motor Controller Specifications
Specifications Specifications Standard Features Optional Features Installation Setup Communications Power Wiring Control Wiring Keypad Software Starting and Stopping Modes Protection and Diagnostics Metering
48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0.
48 Series - Relay interface modules 8 A Features 48.12 2 Pole Safety relay interface modules, 15.8 mm wide 48.12-2 Pole 8 A (screw terminal) DC sensitive coils Relay with forcibly guided contacts according
48 SERIES Relay interface modules 10 A
48 Relay interface modules 10 A 1 CO relay interface modules, mm wide Ideal interface for PLC and electronic systems Type 48.P3 1 CO 10 A s Type 48.31 1 CO 10 A s AC coils or DC sensitive coils Supply
ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.
1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay
Three-phase monitoring relay CM-PFE
Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics
Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection
Technical Data Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection Topic Page 1489-M Miniature Circuit Breakers 2 1492-SP Supplementary Protectors 15 1492-D Circuit Breakers 27 188 Regional
Technicaldata General
Currenttransformer-operatedoverloadrelay,60-90A,1N/O+1N/C Partno. ZW7-90 Articleno. 002618 CatalogNo. XTOT090C3S Deliveryprogramme Product range ZW7 current transformer-operated overload relays Description
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays
38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.
38 Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit 6.2 mm wide EMR - DC, AC or AC/DC
Safety automation solutions
Operating principle, characteristics Preventa safety s types XPS AV,, For and switch monitoring Operating principle Safety s XPS AV, and are used for monitoring circuits conforming to standards EN/ISO
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical
49 Series - Relay interface modules 8-10 - 16 A. Features
Features 1 & 2 Pole relay interface modules 5 µm Gold plate contacts for low level switching capability 49.31-50x0-1 Pole 10 A (screw terminal) 49.52-50x0-2 Pole 8 A (screw terminal) 49.72-50x0-2 Pole
Thermistor motor protection
Thermistor motor protection CM-E Range Thermistor motor protection Thermistor motor protection relays Benefits and advantages Selection table Operating principle and fields of application for thermistor
Relés e Contatores de Estado Sólido SIRIUS
Relés e Contatores de Estado Sólido SIRIUS Coletânea de dados técnicos ( product data sheet ) Agosto/212 SSR - 3RF21 22,5 mm Ponto Zero SSR - 3RF2 45 mm Ponto Zero SSR - 3RF22 45 mm Ponto Zero Trifásico
Catalog January. Heavy industrial power applications Motor contactors and starters
Catalog January Heavy industrial power applications Motor contactors and starters 2006 General contents 0 Heavy Industrial Power Applications Motor Contactors and Starters 1 Contactors and Starters, Type
Micro Contactors. Micro Contactor Relays. Micro Contactors With Solder Pins. Coil voltages. Micro Reversing Contactor. Technical Data.
Micro Contactors Micro Contactor Relays 0 Micro Contactors Micro Contactors With Solder Pins Coil voltages Micro Reversing Contactor 3 Technical Data 4 Dimensions 8 9 Micro Contactor Relays 4pole C Operated
0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N
55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils
Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet
Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order
RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters
Characteristics multifunction voltage control relay RM35-U - range 15..600 V Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main
Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.
Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description
ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories
2CDC 251 014 F0t09 Features Monitoring of three-phase mains for grid feeding Type-tested in accordance with DIN V VDE V 0126-1-1: February 2006 Neutral conductor connection configurable Can also be used
How To Protect A Motor From Overcurrent
Phase ailure elays Type PS and PD Class 8430 Catalog 04 CONTENTS Description.....................................................Page Product Description and Definitions......................................
Power Supplies 3. SDN-P DIN Rail Series
SDN-P DIN Rail Series The SDN DIN Rail power supplies provide industry leading performance. Sag Immunity, transient suppression and noise tolerant, the SDN series ensures compatibility in demanding applications.
Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1
Power Supply Unit, Primary Switched, Narrow Design MINI POWER provides: Extra narrow design with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide-range input
Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages The CM-ESS.M is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
MasterINTERFACE 39 Series - Relay interface modules
MasterINTERFACE 39 Series - Relay interface modules Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Product description Wide rated operational voltage 208 600 V AC Wide rated control supply voltage 100 250 V, 50/60 Hz Rated operational current 18 to 370 A Wide ambient temperature range, -25 to +60 ºC
Safety detection solutions
Presentation, actuator operated etal, types CS A, CS B, CS C and CS E Plastic, double insulated, turret head, types CS P or CS PA or CS TA and CS TE etal, types CS A, CS B, CS C, CS E with or without locking
Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41
Data sheet Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41 The three-phase monitoring relays CM-PSS.x1 monitor the phase parameters phase sequence, phase failure as well as over- and undervoltage.
R.C.C.B. s two-pole LEXIC
87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s two-pole LEXIC 089 06/09/10/11/12/15/16/17/18/ 27/28/29/30/35, CONTENTS PAGES 1. Electrical and mechanical characteristics...
Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...
Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast
Solid State Timers Type F
Solid State Timers Type F Class 9050 CATALOG CONTENTS Description.....................................................Page Product Descriptions............................................. 3 Application
MasterINTERFACE 39 Series - Relay interface modules
MasterINTERFACE 39 Series - 39 Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy ejection by plastic
Bulletin 1489 Circuit Breakers. Selection Guide
Bulletin 1489 s Selection Guide Bulletin 1489-A Overview/Description Bulletin 1489-A s Energy-limiting design protects downstream components better than conventional breakers during short circuits Field-mountable
Safety technique. Emergency stop module BO 5988 safemaster
Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1
40 Series - Miniature PCB/Plug-in relays 8-10 - 16 A. Features 40.31 40.51 40.52
Features 40.31 40.51 40.52 1 & 2 Pole relay range 40.31-1 Pole 10 A (3.5 mm pin pitch) 40.51-1 Pole 10 A (5 mm pin pitch) 40.52-2 Pole 8 A (5 mm pin pitch) PCB mount - direct or via PCB socket 35 mm rail
Telemecanique Zelio Relay complementary and easy to assemble
Telemecanique Zelio Relay complementary and easy to assemble Get more with the world s Power & Control specialist RS interface relays Compact dimensions, enabling multiplication of contacts in electrical
BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview
BETA Switching Siemens AG 200 5TT5 Insta contactors, AC technology Overview The 5TT5 Insta contactors are equipped with an AC magnetic system and are ideal for use under harsh conditions. The auxiliary
ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG 110 084 R0011
, 2CDG 110 084 R0011 2CDC 071 112 F0008 The Fan Coil Actuator is a modular installation device (MDRC) in pro M design. It is intended for installation in the distribution board on 35 mm mounting rails.
Switching Devices Contactors and Contactor Assemblies Special Applications
Switching Devices Contactors and Contactor Assemblies Special Applications Price groups PG 1B, 1H /2 Introduction Contactors for special applications / SIRIUS 3RT1 contactors for resistive loads (AC-1),
Circuit Breakers. NRC Series. NRC Series. 900 www.idec.com
Switches & Pilot Lights Display Lights NRC series circuit breakers offer circuit protection which is far superior to using fuses in applications containing relay circuits, motor circuits, heater circuits,
Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase
Extract from the online catalog STEP-PS/1AC/12DC/1.5 Order No.: 2868567 DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Commercial data EAN 4046356292924 Pack 1 pcs. Customs tariff
Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)
Data sheet Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) The temperature monitoring relays CM-TCS monitor overtemperature,
Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous
Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of
80 Series - Modular timers 16 A. Features 80.01 80.11
80 Series - Modular timers 16 A Features 80.11 Multi-function and mono-function timer range - Multi-function & multi-voltage 80.11 - On-delay, multi-voltage 17.5 mm wide Six time scales from 0.1s to 24h
Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
Manual Motor Starter MS 116 up to 16 A Technical Data
Manual Motor Starter MS 116 up to 16 A Technical Data Type MS 116 Standards: Major International IEC 60 947-4-1 / IEC 60 947-2 and European Standards EN 60 947-4-1 / EN 60 947-2 Approvals, Certificates
RY2 miniature industrial relays
6 RY2 Relays of general application For plug-in sockets, 35 mm rail mount acc. to PN-EN 60715 or on panel mounting Flat insert connectors - faston x 0,5 mm Recognitions, certifications, directives: RoHS,
Control Devices Catalogue. Control Devices. Preferred and Standard Products
Control Devices Catalogue Control Devices Preferred and Standard Products KOP.J Timer Electronic 22.5 mm Characteristics Mounting KOP.J 22.5 mm mono or multifunction high immunity to interference surface
Tmax MCCBs. Molded case circuit breakers. Tmax
Molded case circuit breakers Introduction ABB is once again demonstrating its commitment to new product development and its superiority in product performance. Never before has the industry seen such high
Circuit Breakers. Next Generation of Protection Capabilities
Circuit Breakers Next Generation of Protection Capabilities Circuit Breaker Offering Rockwell Automation offers a full line of Allen-Bradley circuit breakers and motor protection devices to help meet many
Thermistor motor protection relays CM-MSS.22 and CM-MSS.23
Data sheet Thermistor motor protection relays CM-MSS.22 and CM-MSS.23 The thermistor motor protection relays CM-MSS.22 and CM-MSS.23 monitor the winding temperature of motors and protect them from overheating,
Pluggable interface relays CR-P Pcb relays
2CDC 293 034 F0004 1 2 4 3 Features 9 different supply s: DC versions: 12 V, 24 V, 48 V, 110 V AC versions: 24 V, 48 V, 110 V, 120 V, 230 V Output contacts: 1 c/o (16 A) or 2 c/o (8 A) Cadmium-free contact
Relays & Sockets. RH Series Compact Power Relays. Part Number Selection
RH Key features SPDT through PDT, 0A contacts Compact power type relays Miniature power relays with a large capacity 0A contact capacity Compact size saves space Contact SPDT DPDT PDT PDT RH Series Compact
Relays and Timers Specifications Bulletin Number 700
Technical Data Relays and Timers Specifications Bulletin Number 700 Topic Page General Purpose Relays 2 Timing Relays 41 NEMA Industrial Relays 81 IEC Control Relays 93 Solid State Relays 109 Additional
Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.
Overview Switch and button modules The dimensions of the switch and button modules are adapted to the electronic components in the integral housing. The modules are equipped with the universal clip-on
3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,
Automation Technology > Industrial Controls > Switching Devices > Contactors and Contactor Assemblies > Power Contactors for Switching Motors > Contactors SIRIUS 3RT10, 3-pole, 3... 250 kw 3RT1015-1BB41
BETA Protecting SITOR Semiconductor Fuses
BETA Protecting SITOR Semiconductor Fuses /2 Product overview /3 /17 SITOR, cylindrical fuse design /22 SILIZED, NEOZED and DIAZED design Siemens ET B1 /2008 Product overview Overview Devices Page Field
RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER
Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.
SURGE PROTECTIVE DEVICES
SURGE PROTECTIVE DEVICES 1. INTRODUCTION In order to ensure safety of people, protection of equipment and, to a certain extent, continuity of supply, insulation co-ordination aims at reducing the likelihood
Voltage Regulator SPAU 341 C. Product Guide
Issued: July 1998 Status: Updated Version: D/25.04.2006 Data subject to change without notice Features Comprehensive voltage regulation for power transformers with on-load tapchangers in distribution substations
Molded Case Circuit Breaker Specifications Bulletin Number 140U-D
Technical Data Molded Case Circuit Breaker Specifications Bulletin Number 140U-D Topic Page Product Line Overview 2 Specifications 3 Trip Curves 4 Approximate Dimensions 6 Additional Resources These documents
Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.
Low voltage Direct Current Network Compact NSX DC PV Circuit breakers and switch disconnectors for solar application Catalogue 2012 Compact NSX DC PV A complete DC offer for solar application from 80
Vario-Series Accessories
Accessories and spare parts for GMW analogue panel meters and controllers Current Transformers pages 2-9 Shunt Resistors 10-11 Voltage Dividers 12 Power supply for indicator/controllers 13 Blanking Plates
CompactLogix Power Supplies Specifications
Technical Data CompactLogix Power Supplies Specifications 1768 CompactLogix Power Supplies Catalog Numbers 1768-PA3, 1768-PB3 1769 Compact I/O Power Supplies Catalog Numbers 1769-PA2, 1769-PB2, 1769-PA4,
Series 8146/5-V37 and Series 8150/5-V37
www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection
60 Series - General purpose relays 6-10 A. Features 60.12 60.13
Features 60.12 60.13 Plug-in mount 10 A General purpose relay 2 & 3 pole changeover contacts Cadmium Free contacts (preferred version) AC coils & DC coils UL Listing (certain relay/socket combinations)
Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000
Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000 Description Firetrol FTA1000 Full Voltage Fire Pump Controllers are intended for use with electric motor driven fi re pumps
Redundancy Module QUINT-DIODE/40
Redundancy Module QUT DIODE provides: 00% decoupling of power supplies connected in parallel Can be installed in potentially explosive areas Load currents up to 60 A supported Easy assembly by snapping
3753 en - 04.2004/b VE/B - VE/RG Va V riable speed drives
3753 en 04.2004/b Variable speed drives LEROYSOMER's drives provide SPEED VARIATION for a DC motor, SIMPLY and ECONOMICALLY from a singlephase power supply. CMStype technology is used. These products conform
ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x.16.2.1, 2CDG1101xxR0011
Technical Data 2CDC505051D0205 ABB i-bus KNX Product description Switch Actuators SA/S x.16.2.1, 16 A are modular installation devices in ProM design for installation in the distribution board. They are
Control relays RH plug-in relays
Presentation Control relays RH plug-in relays The range The range of RH plug-in control relays with single socket type common to all models and standard front face includes the following models of 5 A
Installation Contactors. Technical Catalogue. Type ESB. abb. ABB STOTZ-KONTAKT GmbH 1 2CDC 103002 C0201
Technical Catalogue Installation Contactors Type ESB abb ABB STOTZ-KONTAKT GmbH 1 CDC 10300 C001 ABB STOTZ-KONTAKT GmbH CDC 10300 C001 Low Voltage Products and Systems We ensure safety and comfort for
PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors
PRODUCT GUIDE SL Medium Voltage IEC Vacuum Contactors Table of Contents 1 Overview Introduction....................................................2 Features........................................................2