Motor circuit-breakers
|
|
- Lee Ross
- 7 years ago
- Views:
Transcription
1 Thermal-magnetic motor circuit-breakers type GV2-M GV2-M Thermal-magnetic motor circuit-breakers GV2-M Pushbutton control Standard power ratings Setting Magnetic Thermal Reference Weight of 3-phase motors range of tripping current 50/60 Hz in category AC-3 thermal current Ithe in trips Id ± 20 % GV2-Miii 230 V V 440 V 500 V 690 V enclosure kw kw kw kw kw A A A kg GV2-M GV2-M GV2-M GV2-M GV2-M GV2-M GV2-M GV2-M GV2-M GV2-M GV2-M GV2-M GV2-M GV2-M GV2-M Thermal-magnetic motor circuit-breakers GV2-M with built-in auxiliary contact block With instantaneous auxiliary contact block : - GV2-AE, add suffix AETQ to the motor circuit-breaker reference selected above. Example : GV2-M0 becomes GV2-M0AETQ. - GV2-AE, add suffix AETQ to the motor circuit-breaker reference selected above. Example : GV2-M0 becomes GV2-M0AETQ. - GV2-AN, add suffix ANTQ to the motor circuit-breaker reference selected above. Example : GV2-M0 becomes GV2-M0ANTQ. These thermal-magnetic motor circuit-breakers with built-in contact block are sold in lots of 20 parts in a single pack. GV2-M GV2-AX GV2-AD, AM, AN, AU, AS, AX GV2-AE Block GV2-AD, AM, AN Block GV2-AU, AS, AX 5 50/60 89 X X ,3 9, () X Electrical clearance 40 mm for Ue 690 V () Maximum Mounting of GV2-M On panel with adaptor plate GV2-AF02 On pre-slotted mounting plate On mounting rail DZ5-MB20 On mm " rail AM-PA GV2-AF02 c 78.5 on AM-DP200 ( x 7.5) AF-EA4 c 86 on AM-DE200, ED200 ( x 5) 4,2 DZ5-MB20 DZ5-ME8 50/ c 80 5 /84 Te
2 Thermal-magnetic motor circuit-breakers type GV2-P Thermal-magnetic motor circuit-breakers GV2-P Control by rotary handle Standard power ratings Setting Magnetic Reference Weight of 3-phase motors range of tripping 50/60 Hz in category AC-3 thermal current trips Id ± 20 % 230 V V 440 V 500 V 690 V kw kw kw kw kw A A kg GV2-P GV2-P GV2-P GV2-P GV2-P GV2-P GV2-P GV2-P GV2-P GV2-P GV2-P GV2-P GV2-P GV2-P GV2-P GV2-P GV2-AD, AM, AN, AU, AS, GV2-AK00 Block GV2-AD, AM, AN 4 Block GV2-AU, AS X 98 9,3 9,3 8() 8 5 Ø5, ± X2 X2 40 mm X Electrical clearance 40 mm for Ue V, or 80 mm for Ue 440 V, or 20 mm for Ue 500 and 690 V Mounting of GV2-P On panel On pre-slotted mounting plate Adaptor plate GK2-AF0 On mm " mounting rail AM-PA ED200 ( x 5) AF-EA4 06 3,5 3,5 24 9,5 54 Te /85
3 GV2-V02 GV-L3 GV2-AK00 GV2-AX GV2-M GV2-M, GV2-RT GV2-AD GV2-AM GV2-AU GV2-P GV2-AM GV2-AS GV2-AE, AE20 GV2-AE GV2-AE GV2-AN GV2-AN /86 Te
4 Illustrations : page /86 Dimensions : pages /84 and /85 Thermal-magnetic motor circuit-breakers types GV2-M, GV2-RT and GV2-P Accessories Contact blocks (5) Description Mounting Contact types Sold in Unit Weight lots of reference kg Instantaneous Front () N/O or N/C (2) 0 GV2-AE 0.05 auxiliary ( block per N/O + N/C 0 GV2-AE contacts breaker) N/O + N/O 0 GV2-AE Side (up to 2 blocks N/O + N/C GV2-AN on LH side of breaker) N/O + N/O GV2-AN Fault Instantaneous Fault Side (3) N/O + N/O GV2-AD signalling ( block N/O + N/C GV2-AD contact + on LH instantaneous side of N/C + N/O GV2-AD auxiliary contact breaker) N/C + N/C GV2-AD Short-circuit Side C/O GV2-AM 0.0 signalling ( block on LH common contact side of breaker) point Electric trips Mounting Type Voltage Reference Weight kg Side Undervoltage 0 5 V 50 Hz GV2-AU ( block on trip 60 Hz GV2-AU RH side of V 50 Hz GV2-AU breaker) 60 Hz GV2-AU V 50 Hz GV2-AU Hz GV2-AU V 50 Hz GV2-AU V 60 Hz GV2-AU V 50 Hz GV2-AU V 60 Hz GV2-AU Add-on contact blocks Shunt 0 5 V 50 Hz GV2-AS trip 60 Hz GV2-AS V 50 Hz GV2-AS Hz GV2-AS V 50 Hz GV2-AS Hz GV2-AS V 50 Hz GV2-AS V 60 Hz GV2-AS V 50 Hz GV2-AS V 60 Hz GV2-AS Undervoltage 0 5 V 50 Hz GV2-AX5 0.0 trip 60 Hz GV2-AX6 0.0 INRS (4) V 50 Hz GV2-AX Hz GV2-AX V 50 Hz GV2-AX Hz GV2-AX V 50Hz GV2-AX 0.0 Description Mounting Operation Sold in Unit Weight lots of reference kg Visible Front () 3-pole on incoming GV2-AK isolation ( block per side of GV2-P motor block breaker) circuit-breaker 00 ka limiter At top GV-L Sealing kit For GV2-M Front 0 GV2-V () Mounting of a GV2-AE contact block or a GV2-AK00 visible isolation block on GV2-P. (2) Choice of N/C or N/O contact operation depending on which way round the reversible block is mounted. (3) The GV2-AD is always mounted next to the circuit-breaker. (4) Safety device for dangerous machines conforming to INRS and VDE 03. Can only be mounted on GV2-M. (5) Maximum of 2 contact blocks on left hand side of breaker. Te /87
5 GV2-G4 GV-G09 GV2-G4 GV2-G254 GV-G0 GV2-G05 LA9-E07 GK2-AF0 GV2-GA0 GV2-AF0 GV-G02 GV2-AF02 GV2-AP0 2 TRIP. RESET GV2-V03 O /88 Te
6 Thermal-magnetic motor circuit-breakers types GV2-M and GV2-P Accessories Illustrations : page /88 Mounting accessories Description Application Sold in Unit Weight lots of reference kg Motor starter With 3-pole connection for GK2-AF adaptor plate mounting of a GV2 and an LC-D09 to D25 contactor Adaptor plate For screw fixing of a GV2-M 0 GV2-AF mm height To allow GV2-M and 0 GV-F compensation plate GV2-L/P to be mounted on a common busbar Combination block Between GV2-M and 0 GV2-AF LC-K or LP-K contactor Cabling accessories Description Application Pitch Reference Weight mm kg Sets of 3-pole, 2 tap-offs GV2-G A busbars 54 GV-G GV2-G tap-offs 54 GV2-G tap-offs GV2-G GV-G GV2-G tap-offs 54 GV2-G Description Application Sold in Unit Weight lots of reference kg Protective end cover For unused busbar outlets 5 GV-G Terminal blocks for supply Connection from the top GV-G to one or more GV-G0i Can be fitted with a GV2-G or GV2-G0i busbar sets GV-L3 current limiter Flexible 3-pole connection Centre distance between 0 GV-G For connecting a GV2 mounting rails: to an LC-D09 D mm contactor Marking accessories Description Application Sold in Unit Weight lots of reference kg Clip-in marker holders For GV2-M (8 x 7 mm) 00 LA9-D (supplied with each For GV2-P (8 x 22 mm) 00 LA9-D motor circuit-breaker) Padlockable external operator Description Reference Weight kg For GV2-P Black handle, blue legend plate GV2-AP (50 to 290 mm) Red handle, yellow legend plate GV2-AP Padlocking device For all GV2 devices 6 padlocks, Ø 6 mm shank max. GV2-V (padlock not supplied) GV2-AF0 GV2-M + GV-L3 (current limiter) 7.5 mm height compensation plate GV2-M + K contactor combination GV-F03 X X X 0 mm for Ue 230 V or 30 mm for 230 V < Ue 690 V Te /89
7 GV2- MC GV2-V0 GV2-K0 GV2-MP GV2-E0 GV2-CP GV2-SN /90 Te
8 Thermal-magnetic motor circuit-breakers types GV2-M and GV2-P Illustrations : page /90 Enclosures for thermal-magnetic motor circuit-breakers GV2-M Application Type Degree of protection Reference Weight of enclosure kg For motor circuit-breakers Surface IP 4 GV2-MC with or without accessories mounting, (maximum of accessory double on right and left for GV2-MCi insulated with IP 55 GV2-MC and GV2-MP0 or MP02, protective accessory only on right conductor. for GV2-MP03 and GV2-MP04) Sealable IP 55 for GV2-MC cover. temperature < + 5 C Flush IP 4 (front face) GV2-MP0 0.5 mounting with IP 4 GV2-MP protective (reduced flush mounting) conductor IP 55 (front face) GV2-MP Front plate IP 55 GV2-MP (reduced flush mounting) Application Degree of protection Reference Weight kg For direct control, IP 55 GV2-CP through a panel, of a GV2-M mounted in an enclosure Accessories common to all enclosures (to be ordered separately) Description Sold in Unit Weight lots of reference kg Padlocking device () GV2-V for GV2-M operator (padlocking is only possible in the O position) Mushroom head Spring return GV2-K stop pushbutton () Ø 40 mm, red Latching Key release GV2-K (key n 5) Turn to GV2-K release Sealing kit For IP 55 0 GV2-E enclosures and front plate IP 55 0 GV2-E for temperature < + 5 C Neutral link 0 GV2-N Description Voltage Colour Sold in Reference Weight V lots of kg Neon indicator light 0 Green 0 GV2-SN Red 0 GV2-SN Orange 0 GV2-SN Clear 0 GV2-SN /240 Green 0 GV2-SN Red 0 GV2-SN Orange 0 GV2-SN Clear 0 GV2-SN /440 Green 0 GV2-SN Red 0 GV2-SN Orange 0 GV2-SN 0.09 Clear 0 GV2-SN () Supplied with IP 55 sealing kit. Te /9
9 Thermal-magnetic motor circuit-breakers types GV2-M and GV2-P Dimensions, mounting : pages : 909/2 to 909/5 Surface mounting enclosure GV2-MC0i Front plate GV2-CP2 47 () 2xØ5,3x6, x Ø3,3 Ø7 62 2, ,5 () 4 knock-outs for 6 mm plastic cable glands or n 6 conduit Flush mounting enclosure GV2-MP0i (bracket cut-out) GV2-MP0i GV2-MP0, MP02 GV2-MP03, MP04 a , a 93,5 06, ,5 GV2- a a MP0, MP02 7 MP03, MP /92 Te
10 Thermal-magnetic motor circuit-breakers types GV2-M and GV2-P Dimensions, mounting : pages /84 to /90 Sets of busbars GV-G07, GV2-G0, GV2-G03, with terminal block GV2-G05 3 a l p 63 8 l p GV-G07 (4 x 54 mm) GV2-G0 (4 x mm) 79 GV2-G03 (4 x mm) a No. of tap-offs GV-G GV2-G GV2-G Sets of busbars GVi-G0i with terminal block GV-G09 Sets of busbars GV-G08, GV2-G02, GV2-G04 GV-G09 l 30 l GV-G08 (2 x 54 mm) 98 GV2-G02 (2 x mm) 89 GV2-G04 (2 x 72 mm) 6 Set of busbars GV2-G07 Set of busbars GV2-G Te /93
11 Magnetic motor circuit-breakers type GV2-L Magnetic motor circuit-breakers GV2-L Rotary handle Standard power ratings Magnetic Tripping Use in Reference Weight of 3-phase motors protection current association 50/60 Hz in category AC-3 rating Id ± 20 % with thermal overload 230 V V 440 V 500 V 690 V relay kw kw kw kw kw A A kg GV2-L LR2-D303 GV2-L LR2-D304 GV2-L LR2-D305 GV2-L LR2-D306 GV2-L LR2-D307 GV2-L LR2-D308 GV2-L LR2-D30 GV2-L LR2-D32 GV2-L LR2-D34 GV2-L LR2-D36 GV2-L LR2-D32 GV2-L LR2-D322 GV2-L GV2-L GV2-AD, AM, AN, AU, AS, GV2-AK00 4 Block GV2-AD, AM, AN Block GV2-AU, AS 89 X X2 9,3 9,3 8 () 8 X2 40 mm X Electrical clearance 40 mm for Ue V, or 80 mm for Ue 440 V, or 20 mm for Ue 500 and 690 V () Maximum Mounting of GV2-L On panel On pre-slotted mounting plate Adaptor plate GK2-AF0 On mounting rail AM-DE200, AM-PA AM-ED200 ( x 5) AF-EA Ø5,5 05±5 06 3,5 3,5 24 9,5 54 /94 Te
12 Magnetic motor circuit-breakers type GV2-LE GV2-LE Magnetic motor circuit-breakers GV2-LE Rocker lever Standard power ratings Magnetic Tripping Use in Reference Weight of 3-phase motors protection current association 50/60 Hz in category AC-3 rating Id ± 20 % with thermal overload 230 V V 440 V 500 V 690 V relay kw kw kw kw kw A A kg LR2-K0302 GV2-LE LR2-K0303 GV2-LE LR2-K0304 GV2-LE LR2-K0304 GV2-LE LR2-K0305 GV2-LE LR2-K0305 GV2-LE LR2-K0306 GV2-LE LR2-K0306 GV2-LE LR2-K0307 GV2-LE LR2-K0307 GV2-LE LR2-K0308 GV2-LE LR2-K030 GV2-LE LR2-K032 GV2-LE LR2-K032 GV2-LE LR2-K034 GV2-LE LR2-K034 GV2-LE LR2-K036 GV2-LE LR2-D34 GV2-LE LR2-D36 GV2-LE LR2-D32 GV2-LE LR2-D322 GV2-LE LR2-D23 GV-LE GV2-AD, AM, AN, AU, AS GV2-AE On pre-slotted mounting plate On mounting rails DZ5-MB20 OAM-PA Block GV2-AD, AM, AN Block GV2-AU, AS 5 GV2-AF02 AF-EA4 DZ5-MB20 DZ5-ME8 0 50/ ,3 9,3 8 8 () 5 Te /95
13 GV2-AK00 GV2-AU GV2-LE GV2-AD GV2-AM GV2-AS GV2-L GV2-AM GV2-AE, AE20 GV2-AE GV2-AE GV2-AN GV2-AN /96 Te
14 Magnetic motor circuit-breakers types GV2-L and GV2-LE Accessories Illustrations : page /94 Dimensions : pages /92 and /93 Contact blocks (4) Description Mounting Contact types Sold in Unit Weight lots of reference kg Instantaneous Front () N/O or N/C (2) 0 GV2-AE 0.05 auxiliary ( block per N/O + N/C 0 GV2-AE contacts breaker) N/O + N/O 0 GV2-AE Side (up to 2 blocks N/O + N/C GV2-AN on LH side of N/O + N/O GV2-AN breaker) Fault Instantaneous Fault Side (3) N/O + N/O GV2-AD signalling ( block N/O + N/C GV2-AD contact + on LH side instantaneous of breaker) N/C + N/O GV2-AD auxiliary contact N/C + N/C GV2-AD Short-circuit Side C/O GV2-AM 0.0 signalling ( block on LH common contact side of breaker) point Electric trips Mounting Type Voltage Reference Weight kg Side Undervoltage 0 27 V 50 Hz GV2-AU ( block on trip 60 Hz GV2-AU RH side of V 50 Hz GV2-AU breaker) 60 Hz GV2-AU V 50 Hz GV2-AU Hz GV2-AU V 50 Hz GV2-AU V 60 Hz GV2-AU V 50 Hz GV2-AU V 60 Hz GV2-AU Add-on contact blocks Overvoltage 0 5 V 50 Hz GV2-AS trip 60 Hz GV2-AS V 50 Hz GV2-AS Hz GV2-AS V 50 Hz GV2-AS Hz GV2-AS V 50 Hz GV2-AS V 60 Hz GV2-AS V 50 Hz GV2-AS V 60 Hz GV2-AS Description Mounting Operation Reference Weight kg Visible Front () 3-pole visible isolation GV2-AK isolation ( block per on incoming side of block breaker) GV2-L motor circuit-breaker () Mounting of a GV2-AE contact block or a GV2-AK00 visible isolation block on GV2-L. (2) Choice of N/C or N/O contact operation depending on which way round the reversible block is mounted. (3) The GV2-AD is always mounted next to the circuit-breaker. (4) Maximum of 2 contact blocks on left hand side of breaker. Te /97
Electrical auxiliaries 0 For i DPN (DPN), C60 and C120
Circuit protection For i DPN (DPN), C60 and C120 Function They remotely trip or indicate circuit-breakers, with or without Vigi module. Description b They are mounted to the left of the circuit-breaker
More informationThermal-Magnetic Circuit Breaker 3120-...-M1-..
Thermal-Magnetic Circuit Breaker -...-M-.. Description Single or two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 34). The addition of a magnetic tripping
More informationElectronic overload relay EF19 and EF45
Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor
More informationCircuit Breakers. Next Generation of Protection Capabilities
Circuit Breakers Next Generation of Protection Capabilities Circuit Breaker Offering Rockwell Automation offers a full line of Allen-Bradley circuit breakers and motor protection devices to help meet many
More informationD-Line Contactors, Overload Relays and Accessories
D-Line Contactors, Overload Relays and Accessories Class 850 CONTENTS Description......................................................Page General Information...............................................
More informationComponents for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, "Flameproof Enclosure" Series 8264. www.stahl.
> Installation chamber can be fully used > Up to three mounting levels can be used > Saving of weight > Compact > Easy to combine > 26 enclosure versions > 15 window versions www.stahl.de 10303E00 The
More informationSafety detection solutions
Presentation, actuator operated etal, types CS A, CS B, CS C and CS E Plastic, double insulated, turret head, types CS P or CS PA or CS TA and CS TE etal, types CS A, CS B, CS C, CS E with or without locking
More informationPSR The compact range Description
Description The PSR range is the most compact of all the ABB softstarter ranges, thereby making it possible to fit many devices into the same enclosure. The system concept with Manual Motor Starters provides
More information8146/5 Series Breaker Panelboards
8146/5 Series Breaker Panelboards DISTRIBUTION BREAKER PANELBOARDS FOR HAZARDOUS & CORROSIVE ENVIRONMENTS Breaker Panels Features: Wide variety of Flameproof branch circuit breakers for Zone 1 & Division
More informationElectronic overload relay EF65, EF96 and EF146
Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays.
More informationR.C.C.B. s two-pole LEXIC
87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s two-pole LEXIC 089 06/09/10/11/12/15/16/17/18/ 27/28/29/30/35, CONTENTS PAGES 1. Electrical and mechanical characteristics...
More informationSIRCOVER. Manual changeover switches from 125 to 3200 A. Changeover switches. Function. Advantages. The solution for.
The solution for Changeover switches svr_099_b_1_cat > Manufacturing industry. > Power distribution. 3200 Strong points svr_059_a_1_cat > complete range. > Easy connections. > Stable positions. > mproved
More informationMagnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...
Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast
More informationPendant control stations 6
Characteristics 6 Environment Conformity to standards EN/IEC 6097-5-1 EN/IEC 600-, UL 508, CSA C- n EN/IEC 6097-5-5 and EN/ISO 850 for versions with trigger action Emergency stop Product certifications
More informationMOTOR PROTECTIVE DEVICES
W MOTOR PROTECTIVE DEVICE, SERIES MP 206 BE400206 BE400306 Inherently stable without back-up fuseup to 4 A at 400 V AC, > 4 A main back-up fuse 100 A gl Thermal and magnetic release Terminal and accessory
More informationPlug and Socket Devices CES 63 A Series 8579
www.stahl.de > Switch socket / plug 63 A > Large switch handle with clear switch position indication padlockable in 0- and I-position > Low insertion and withdrawal forces through individually encapsulated
More informationLC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil
Product data sheet Characteristics LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationSeries 8146/5-V37 and Series 8150/5-V37
www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection
More informationManual Motor Starter MS 116 up to 16 A Technical Data
Manual Motor Starter MS 116 up to 16 A Technical Data Type MS 116 Standards: Major International IEC 60 947-4-1 / IEC 60 947-2 and European Standards EN 60 947-4-1 / EN 60 947-2 Approvals, Certificates
More informationSafety automation solutions
Operating principle, characteristics Preventa safety s types XPS AV,, For and switch monitoring Operating principle Safety s XPS AV, and are used for monitoring circuits conforming to standards EN/ISO
More informationWiring diagrams. Compact NSX. Contents
Compact NSX Wiring diagrams Contents Functions and characteristics A-1 nstallation recommendations B-1 Dimensions and connection C-1 Compact NSX100 to 630 Fixed circuit breakers D-2 Plug-in / withdrawable
More informationSENTRON Switching and Protection Devices Air Circuit Breakers
Siemens AG 9 SENTRON Switching and rotection Devices Air Circuit reakers 5 5/ Introduction 3WL Air Circuit reakers 3WL Air Circuit reakers/ Non-Automatic Air Circuit reakers up to 63 A (AC) 5/6 General
More informationType: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information
Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC
More informationLow voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.
Low voltage Direct Current Network Compact NSX DC PV Circuit breakers and switch disconnectors for solar application Catalogue 2012 Compact NSX DC PV A complete DC offer for solar application from 80
More informationRM4TG20 three-phase network control relay RM4-T - range 200..500 V
Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking
More informationPhone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Product description Wide rated operational voltage 208 600 V AC Wide rated control supply voltage 100 250 V, 50/60 Hz Rated operational current 18 to 370 A Wide ambient temperature range, -25 to +60 ºC
More informationSpare parts Catalogue
Technical catalogue Spare parts Catalogue Low voltage circuit-breakers Product support ABB SACE SDC0000D00 Not every original spare parts are really original spare parts. Availability of spare parts for
More informationAF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101403D0201 24/03/11 AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF09(Z) contactors are used for controlling power circuits
More informationCircuit Breakers. NRC Series. NRC Series. 900 www.idec.com
Switches & Pilot Lights Display Lights NRC series circuit breakers offer circuit protection which is far superior to using fuses in applications containing relay circuits, motor circuits, heater circuits,
More information3RV Motor Starter Protectors up to 100 A
General data Overview S0 motor 3RV1 motor are compact, current limiting motor which are optimized for load feeders. The motor are used for switching and protecting three-phase induction motors of up to
More informationControl Panel Technical Guide
Control Panel Technical Guide How to select the appropriate motor starters for your HVAC & R* equipments * Heating, Ventilation, Air conditioning & Refrigeration Many machines can be used in a HVAC&R installation
More informationBulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller
Overview/Modes of Operation Bulletin 150 Smart Motor Controller The SMC-3 is a compact, simple to use, solid-state motor controller designed to operate 3-phase motors. It features a built-in overload relay
More informationSUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original
SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original A motor starter is a combination of devices to allow an induction motor to start, run and stop according
More informationVario-Series Accessories
Accessories and spare parts for GMW analogue panel meters and controllers Current Transformers pages 2-9 Shunt Resistors 10-11 Voltage Dividers 12 Power supply for indicator/controllers 13 Blanking Plates
More information3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,
Automation Technology > Industrial Controls > Switching Devices > Contactors and Contactor Assemblies > Power Contactors for Switching Motors > Contactors SIRIUS 3RT10, 3-pole, 3... 250 kw 3RT1015-1BB41
More informationTmax MCCBs. Molded case circuit breakers. Tmax
Molded case circuit breakers Introduction ABB is once again demonstrating its commitment to new product development and its superiority in product performance. Never before has the industry seen such high
More information3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance
SPECIFICATION FOR LOW VOLTAGE SWITCHBOARD SEN I N D E X Description 10 STANDARD TECHNICAL REQUIREMENTS 11 Standards 12 General Operating Conditions 13 General Description Of Switchboard 131 Structure 132
More informationABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories
2CDC 251 014 F0t09 Features Monitoring of three-phase mains for grid feeding Type-tested in accordance with DIN V VDE V 0126-1-1: February 2006 Neutral conductor connection configurable Can also be used
More informationUS Breaker Brand 3 Pole AC Contactors (Square D Telemecanique LC1 Replacements)
4 NC1 D09-D18 NC1 -D32 US Breaker Brand 3 Pole AC Contactors (Square D Telemecanique LC1 Replacements) Standards: UL508, CSA C22.2, IEC 60947, and CE Marked Integral DIN Rail & Base Mounting in One Compact
More informationPlug and Socket Devices SolConeX 16 A Series 8570
www.stahl.de > Switch socket / plug 16 A > Minimal force required to insert and remove > Can be optionally equipped with an auxiliary contact for control and signalling purposes > arge switching handle
More informationVoltage Regulator SPAU 341 C. Product Guide
Issued: July 1998 Status: Updated Version: D/25.04.2006 Data subject to change without notice Features Comprehensive voltage regulation for power transformers with on-load tapchangers in distribution substations
More informationNEXT SOLUTION EXPERT SOLUTION EXCELLENT SOLUTION. Super Solution
NEXT SOLUTION EXPERT SOLUTION EXCELLENT SOLUTION Super Solution Low voltage circuit breakers Susol LV circuit breakers Super Solution Contents Overview Electrical characteristics Trip units Accessories
More informationTechnicaldata General
Currenttransformer-operatedoverloadrelay,60-90A,1N/O+1N/C Partno. ZW7-90 Articleno. 002618 CatalogNo. XTOT090C3S Deliveryprogramme Product range ZW7 current transformer-operated overload relays Description
More information5SV Residual Current Protective Devices
s Siemens AG 2013 SENTRON 5SV Residual Current Protective Devices New portfolio for reliable personnel, material and fire protection Safe protection against residual currents Residual current protective
More informationRDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems
3 072 RDJ10RF RCR10/433 Wireless room temperature controller with 24-hour time switch and LCD Programmable, for heating systems RDJ10RF/SET Operating modes: Automatic, Comfort, Energy Saving, and Frost
More informationBreaking and protection devices
Breaking and protection devices 05 POWER GUIDE 2009 / BOOK 05 INTRO The purpose of selecting a protection device is to perform two essential functions: to protect people and to protect trunking, while
More informationIZM ACB/Circuit-breakers. Robust safety. Extract from Main Catalogue HPL2010 IZM26 Circuit-breakers IN26 Switch-disconnectors
IZM ACB/Circuit-breakers Robust safety Extract from Main Catalogue HPL2010 IZM26 Circuit-breakers IN26 Switch-disconnectors t [s] 0.1 0.05 0.04 0.03 0.02 0.01 20 1230DIA-125 (70C1043) 30 40 50 60 80 100
More informationMureva Assembly surface mounted wiring devices
1.0 Waterproof Assembly surface Switches P124543 P124547 External dimensions : 72 x 72 x 47 mm.. Assembly surface rockers become illuminated using bulbs and indicators in option. They can carry a label
More informationCurrent valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
More informationSentron Series Circuit Breakers
Sentron Series Circuit Breakers Siemens Sentron Series circuit breakers are available in nine frame sizes: ED, FD, JD, LD, LMD, MD, ND, PD, and RD. Sentron Series circuit breakers have a wide range of
More informationHERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
More informationTechnical catalogue. Modular DIN rail components Installation contactors
Technical catalogue Modular DIN rail components Installation contactors Installation Contactors Overview... ESB Installation Contactors 0 A / AC-/AC-7a ESB0...4 4 A / AC-/AC-7a ESB4...5 40 A / AC-/AC-7a
More informationTHERMAL RELAYS, MOTORSTARTERS
THERMAL RELAYS, MOTORSTARTERS MH mini thermal relay plugged version H0K thermal relay with adapter H0K thermal relay plugged version T I thermal relay plugged version H thermal relay with current transformer
More informationGivare NC-SRS 280 och 880
Givare NC-SRS 280 och 880 Aratron AB/Nordic Control, 02 03 SRS280SEALED ROTARY SENSOR PERFORMANCE ±2 Resistance ±20% Hysteresis (repeatability) Accuracy Applied voltage maximum Resolution Output smoothness
More informationCatalog January. Heavy industrial power applications Motor contactors and starters
Catalog January Heavy industrial power applications Motor contactors and starters 2006 General contents 0 Heavy Industrial Power Applications Motor Contactors and Starters 1 Contactors and Starters, Type
More informationSingle-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable
Features 70.11 70.31 70.41 Electronic voltage monitoring relays for single and three-phase applications Multifunctional types, providing the flexibility of monitoring Undervoltage, Overvoltage, Window
More informationPositive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous
Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of
More informationVoltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
More informationACS-30-EU-EMDR-10-MOD
Multi-application heat tracing Control and Monitoring in commercial and residential buildings Roof & Gutter de-icing sensor module Technical Information Approvals Module IP rating Ambient operating temperature
More informationADS8 IP54 Direct-On-Line Starter Technical Focus. Replaces ADS7 Rated up to 9kW
ADS8 IP54 Direct-On-Line Starter Technical Focus Replaces ADS7 Rated up to 9kW New ADS8 Motor Starter The new ADS8 range of motor starters replaces the successful ADS7 range which was introduced 20 years
More informationManual motor starter MS116
Data sheet Manual motor starter MS116 Manual motor starters are electromechanical devices for motor and circuit protection. These devices offer local motor disconnect means, manual ON/ OFF control, and
More informationVLT Series 3500 Adjustable Frequency Drive Instruction Manual
Adjustable Frequency Drive Instruction Manual VLT Series 3500 Instruction Manual 175R5237 - Document Version 5.00 This manual applies to all VLT Series 3502-3800 Adjustable Frequency Drives with software
More information3AH5 Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG 11.05 2010
Medium-Voltage Equipment Selection and Ordering Data Catalog HG 11.05 2010 Answers for energy. R-HG11-172.tif 2 Siemens HG 11.05 2010 Contents Contents Page 3AH5 Vacuum Circuit-Breakers Medium-Voltage
More informationNumber 1 in efficiency
PowerXL DE1 Variable Speed Starter www.eaton.eu/de1 Number 1 in efficiency The easiest way of variable motor speed NEW Variation DE11 The new device category! The PowerXL DE1 Variable Speed Starter Why
More informationSafety dialogue solutions
General Presentation Emergency stop trip wire switches Emergency stop trip wire switches are designed to: b avert hazards (dangerous phenomena) at the earliest possible moment, or to reduce risks which
More informationABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.
1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay
More informationGeneral Informations 2 Technical data 3 Basic designs 4-8
Contents Page General Informations 2 Technical data 3 Basic designs 4-8 Cam Switches On-Off switches, Changeover switches 9-12 Star-Delta switches 13-15 Multi speed switches 16-20 Control switches 21-23
More information49 Series - Relay interface modules 8-10 - 16 A. Features
Features 1 & 2 Pole relay interface modules 5 µm Gold plate contacts for low level switching capability 49.31-50x0-1 Pole 10 A (screw terminal) 49.52-50x0-2 Pole 8 A (screw terminal) 49.72-50x0-2 Pole
More informationknow-how Giant in distributing electricity for industry Prisma GK
Prisma GK Giant know-how in distributing electricity for industry Installation system up to 630A for electrical power distribution and circuit control. Prisma GK: technology and innovation for an IP55
More informationMini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear
Mini Motor Contactor J7KNA ) Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN-rail) Range from 4 to 5.5 (AC 3, 380/415V) 4 -main pole version (4 AC
More informationELR: ABB range of front panel residual current relays Protection device according to IEC/EN 60947-2 Annex M
ELR: ABB range of front panel residual current relays Protection device according to IEC/EN 60947-2 Annex M Tested, certified, reliable Network monitoring and protection The electronic residual current
More information9013 PUMPTROL Commercial Pressure Switches Type F and 9013 Commercial Pressure Switches Type G. January. Catalog
9013 PUMPTROL Commercial Pressure Switches Type F and 9013 Commercial Pressure Switches Type G Catalog January 07 Contents Commercial Pressure Switches Pressure Switches b Selection..............................................
More informationBulletin 1489 Circuit Breakers. Selection Guide
Bulletin 1489 s Selection Guide Bulletin 1489-A Overview/Description Bulletin 1489-A s Energy-limiting design protects downstream components better than conventional breakers during short circuits Field-mountable
More information0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N
55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils
More informationMaximum Demand Control
Maximum Demand Control There are three terms that appear on the majority of electric company bills: Active energy consumption (kwh) Reactive energy consumption (kvarh) Maximum Demand Traditionally, utility
More informationMolded Case Circuit Breakers, Motor Protection Circuit Breakers, and Motor Circuit Protectors. Technical Data
Molded Case Circuit Breakers, Motor Protection Circuit Breakers, and Motor Circuit Protectors Technical Data Table of Contents Introduction... 4 Definitions... 5 Product Range... 8 Product Line Overview...11
More informationMONITORING RELAYS. w VOLTAGE MONITORING RELAY UR5U1011. w SCHRACK-INFO. w TECHNICAL DATA
w VOLTAGE MONITORING RELAY UR5U1011 w SCHRACK-INFO AC/DC voltage monitoring in 1-phase mains Undervoltage monitoring 1 change over contact Width 17.5 mm Installation design w TECHNICAL DATA 502 1. Functions
More informationRM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC
Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage
More informationTechnical catalog. FORMULA UL New low voltage molded case circuit breakers up to 250A. Power and productivity for a better world TM
Technical catalog FORMULA UL New low voltage molded case circuit breakers up to 2A Power and productivity for a better world TM Index Main characteristics 1 Circuit breakers for power distribution 2 Accessories
More informationBETA Protecting SITOR Semiconductor Fuses
BETA Protecting SITOR Semiconductor Fuses /2 Product overview /3 /17 SITOR, cylindrical fuse design /22 SILIZED, NEOZED and DIAZED design Siemens ET B1 /2008 Product overview Overview Devices Page Field
More informationQuick Connect. quick - simple - efficient. www.g-mw.de
Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power
More informationAll work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.
DIVISION 16 ELECTRICAL SECTION 16100 - ELECTRICAL PART 1 - GENERAL SCOPE All electrical work as shown on the drawings and as necessary to provide a complete electrical system. Include primary service,
More informationNF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101433D0201 28/03/11 NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits.
More informationASSEMBLED SOCKET-COMBINATIONS
ASSEMBLED SOCKETCOMBINATIONS Enclosure extra strong, schockresistant easily open, it provides a comfortable mount it can be connected across a cable gland it consists of a 35 mm mounting rail Window 6
More informationLow Voltage. EasyPact CVS. Moulded-case circuit breakers and switch-disconnectors from 100 to 630 A. Catalogue 2011
Low Voltage EasyPact CVS Moulded-case circuit breakers and switch-disconnectors from 100 to 630 A Catalogue 2011 Safe Reliable Simple The easy choice for quality and value EasyPact CVS LV circuit breakers
More informationSecuring your electrical installations Prisma,
Securing your electrical installations Prisma, an optimised solution for type tested low voltage switchboards up to 3200 A Table of contents Developing installation safety 4 Prisma P * Electrical switchboards
More informationCross-beam scanning system to detect slim objects. 100 mm 3.937 in
891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC
More informationCurrent transformers (CT) & Shunts
Current transformers (CT) & Shunts Genreal overview LV CURRENT TRANSFORMERS Product selection guide Standard industrial transformers?????? TCR - TCRO range NEW 9 9 9 Current summation JVM 0 9 TCR usbar
More informationNM8, NM8S NM8, NM8S. Moulded Case Circuit Breakers. 3. Type designation. 4. Product overview N M 8 / / /
Moulded Case Circuit Breakers NM8, NM8S 3. Type designation 4. Product overview N M 8 / / / NM8 Moulded Case Circuit Breaker Application code Blank: for power distribution; NM8, NM8S Moulded Case Circuit
More informationBETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview
BETA Switching Siemens AG 200 5TT5 Insta contactors, AC technology Overview The 5TT5 Insta contactors are equipped with an AC magnetic system and are ideal for use under harsh conditions. The auxiliary
More informationSMS 4 / SMS 5 safety mat Product information
SMS 4 / SMS 5 safety mat Product information SMS 4 / SMS 5 safety mats Safety mats are used for the protection of man on machinery and plants with hazardous movements. Typical fields of application are,
More informationINDUSTRIAL CONTROLS. APEM, PO BOX 8288, HAVERHILL, MA USA 01835-0788 TOLL FREE: (877) 246-7890 FAX: (781) 245-4531 E-mail: info@apem.
INDUSTRIAL CONTROLS INDUSTRIAL CONTROLS E INDUSTRIAL CONTROLS SELECTION GUIDE Series Description Page A01 & A02 Products & Features 2 A01 & A02 Specifications 3 A01 Illuminated or non-illuminated pushbutton
More informationUnified requirements for systems with voltages above 1 kv up to 15 kv
(1991) (Rev.1 May 2001) (Rev.2 July 2003) (Rev.3 Feb 2015) Unified requirements for systems with voltages above 1 kv up to 15 kv 1. General 1.1 Field of application The following requirements apply to
More informationMolded Case Circuit Breaker Specifications Bulletin Number 140U-D
Technical Data Molded Case Circuit Breaker Specifications Bulletin Number 140U-D Topic Page Product Line Overview 2 Specifications 3 Trip Curves 4 Approximate Dimensions 6 Additional Resources These documents
More information48 SERIES Relay interface modules 10 A
48 Relay interface modules 10 A 1 CO relay interface modules, mm wide Ideal interface for PLC and electronic systems Type 48.P3 1 CO 10 A s Type 48.31 1 CO 10 A s AC coils or DC sensitive coils Supply
More informationA product made in Australia. Insulated Conductor Rail ACTIV-8 PLUS
A product made in Australia Insulated Conductor Rail ACTIV-8 PLUS ACTIV-8 PLUS The Industry Standard in Conductor Rails ACTIV-8 is the most widely used and stocked conductor rail in use in Australia. It
More informationEmergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN 60204-1, VDE 0113 Part 1
MainswitchSurfacemounting Partno. P3-63/I4/SVB Articleno. 207343 CatalogNo. SP3-063-I4CRQ IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual
More informationMotor protection plugs
Motor protection plugs Motor protection plugs Results without motor protection plugs: Do you know the problem of >>...a destroyed engine? >>...a defective arrangement? >>...a burnt through winding by
More informationVoltage monitoring relays CM-ESS.M For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages The CM-ESS.M is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
More informationWE-350 Series ¼ Turn Electric Actuator
WE-350 Series ¼ Turn Electric Actuator Operation and Installation Manual Pg 1 (Rev. 020113) Table of Contents 1.0 General 1.1 Pre-Installation Inspection 1.2 Storage 1.3 Features & General Information
More information