SIRCOVER. Manual changeover switches from 125 to 3200 A. Changeover switches. Function. Advantages. The solution for.

Size: px
Start display at page:

Download "SIRCOVER. Manual changeover switches from 125 to 3200 A. Changeover switches. Function. Advantages. The solution for."

Transcription

1 The solution for Changeover switches svr_099_b_1_cat > Manufacturing industry. > Power distribution Strong points svr_059_a_1_cat > complete range. > Easy connections. > Stable positions. > mproved on load switching. Specific features C -0- > On load switching C-33. Function Bypass 125 are manual multipolar changeover switches with positive break indication. The family includes three ranges: C for dead time switching (-0-), for overlapping contact switching (-+-), and Bypass. This version is a combination of three interlocked switches enabling use with poles or poles. They provide switching, source inversion and changeover under load for two low voltage power circuits, as well as their safety isolation by double breaking per pole. Conformity to standards > EC > EC pprovals and certifications (1) (1) Product reference on request. Enclosed solution dvantages complete product range Three versions of the are available to ensure compatibility with the maximum number of applications: C (-0-) with improved on load switching characteristics and isolation position, with overlapping contacts (-+-) and a Bypass version. Easy connections copper bar connection kit is available for 2000 to 3200 ratings. t enables various types of connection: Flat or edgewise connection with top or bottom bridging. Stable positions s have three stable positions which are not affected by voltage drops or vibrations, thus protecting your load against network interference. mproved on load switching Thanks to its C-23 and C-33 characteristics, which are tested in accordance with standards EC and EC , the C enables secure and reliable switching on all types of load, without the need for pre-breaking upstream. > vailable enclosed from 125 to General Catalogue

2 What you need to know C (-0-) switches have 3 stable positions, and are available as 3 or 4 pole devices. They are available enclosed in a steel or polyester enclosure from 125 to with overlapping contacts (-+-) are 3 or 4 pole devices available from 125 to They are available in a steel enclosure from 125 to With 3 stable positions (-0-), Bypass are a combination of three interlocked switches enabling the use with 3+6 poles or 4+8 poles from 125 to ll ratings are available in a steel enclosure. ll can be utilised with a direct front or external operation handle. acces_226_c_2_cat svr_136_a_1_x_cat Copper bar connection kits enable the connection between the two power terminals of the same pole (fig.1 & fig.2) and the bridging of the poles on the top or bottom side of the switch (fig.3), for ratings 2000, 2500 and Fig. 1 Fig.2 Fig. 3 acces_229_b_2_cat acces_231_a_1_cat Top or bottom flat connection Edgewise connection Top or bottom Top or bottom bridging connection General Catalogue

3 References C -0- No. of poles Switch body Direct handle External handle Shaft for external handle Bridging bars uxiliary contact Terminal shrouds Terminal screens C C C C C C (3)(4) (3)(4) C C C C C C 4040 J2 type Blue Red S2 type Black P Black P (1) 200 mm mm (1) (3)(4) (3)(4) C C C C st /2 nd contact NO/NC (2) (3)(4) (3)(4) (5) (5) C C C C C C C C C C 4180 J3 type Blue Red S4 type Black P mm mm (1) (5) (5) (5) (5) C C C C C C 4320 S5 type Black S5 type Black P mm mm (1) 450 mm (6) 1 st contact NO/NC included included (1) Standard. (2) 2 pieces supplied, one for position and one for position. (3) To fully shroud front, rear, top and bottom 4 references required. (4) To shroud front switch top and bottom 2 references required. (5) 2 pieces supplied, one for top side and another for bottom side. (6) See "Copper bar connection kits" page General Catalogue

4 - + - No. of poles Switch body Direct handle External handle Shaft for external handle Bridging bar uxiliary contact Terminal shrouds Terminal screens (1) (1) (1) (1) (4)(5) (4)(5) (1) 200 mm S2 type Black (2) Black P (2) 320 mm (1) (2) (1) (1) (4)(5) (4)(5) (1) (1) (1) (1) 1 st /2 nd contact NO/NC (3) (4)(5) (4)(5) (6) (6) (1) (1) (1) (1) 200 mm S4 type Black (2) Black P (2) 320 mm (1) (2) (1) (6) (6) (6) (6) (1) vailable enclosed (see "Enclosed changeover switches" page 625). (2) Standard. (3) 2 pieces supplied, one for position and one for position. (4) To fully shroud front, rear, top and bottom 4 references required. (5) To shroud front switch top and bottom 2 references required. (6) 2pieces supplied, one for top side and another for bottom side. General Catalogue

5 References (continued) Bypass No. of poles Switch body Shaft for -0- Direct handle External handle external handle Bridging bar uxiliary contact Terminal shrouds Terminal screens P (1) P (1) P (1) P (1) Black S2 type Black P (2) Black P mm mm (2) (4)(5) (4)(5) P P P (1) P (1) S3 type Black P mm mm P (1) P (1) Black (2) P (1) P (1) P (1) 1 st /2 nd contact NO/NC (3) (4)(5) (4)(5) (4)(5) (4)(5) (6) (6) P (1) P (1) mm P (1) Black Black P mm (2) P (1) 450 mm P (1) (6) (6) (6) P (1) (6) (1) vailable enclosed (see "Enclosed changeover switches" page 625). (2) Standard. (3) 2 pieces supplied, one for position and one for position. (4) To shroud front switch top and bottom 3 references required. (5) To fully shroud front, rear, top and bottom 6 references required. (6) 2 pieces supplied, one for top side and another for bottom side. 332 General Catalogue

6 ccessories Direct operation handle C -0- Handle colour Handle type Reference Blue J2 type Red J2 type Blue J3 type Red J3 type Black S5 type (1) Handle colour Handle type Reference Black B3 type Black C1 type acces_356_a_1_cat acces_129_b_1_cat acces_153_a_2_cat Bypass Handle colour Handle type Reference Black B3 type Black C1 type Black C2 type (1) (1) Double lever handle J2 type handle C1 type handle C2 type handle External operation handle Door interlocked external front operation handles include an escutcheon, are padlockable and must be utilised with an extension shaft. C -0- and -+- External Switching type P (1) Handle Reference P55 S2 type P65 S2 type P65 S2 type P65 S4 type (2) P65 S4 type (2) P65 S5 type (2) (1) P : protection degree according to EC standard. (2) Double lever handle. Bypass Switching type External P (1) Handle Reference P55 S2 type P65 S2 type P65 S3 type P65 V2 type (1) P : protection degree according to EC standard. lternative S-type handle cover colours S2 type handle acces_150_a_2_cat S3 type handle acces_151_a_1_cat S4 type handle acces_152_a_2_cat S5 type handle acces_286_a_1_cat For single lever handles S1, S2, S3 type and for double lever handle S4 type. Other colours: Please consult us. To be ordered Colour in multiples of Handle Reference Light grey 50 S2, S3 type Dark grey 50 S2, S3 type Light grey 50 S4 type Dark grey 50 S4 type acces_198_a_2_cat S-type handle adapter Enables S-type handles to be fitted in place of existing older style SOCOMEC handles. dapter can also be utilised as a spacer to increase the distance between the panel door and the handle lever. Dimensions dds 12 mm to the depth. Colour To be ordered in multiples of External P (1) Reference Black 1 P (1) P : protection degree according to EC standard. acces_187_a_1_cat General Catalogue

7 ccessories (continued) Shaft guide for external operation Required for shaft lengths over 320 mm. To guide the shaft extension into the external handle. This accessory enables handle to engage extension shaft with a misalignment of up to 15 mm. Description Reference Shaft guide Shaft for external handle Standard lengths: mm, mm, mm. C -0- and -+- Length (mm) Dimension X (mm) Reference Other lengths: Please consult us. acces_260_a_2_cat acces_369_a_1_cat Bridging bars For creating a common connection between switches &, on the top or bottom side of the, to enable, for example, the load to be fed from either incoming source ( or ). Section (mm) Reference x x x x x x x x For Bypass, two sets of bridging bars are needed as the switch is composed of three basic switch frames. C -0- and -+- acces_205_a_2_cat acces_041_a_1_cat Bypass acces_208_a_2_cat svr_124_a_1_cat svr_068_a_1_x_cat acces_144_b_1_cat Bypass Length (mm) Dimension X (mm) Reference X acces_202_a_1_x_cat 334 General Catalogue

8 Copper bar connection kits from 2000 to Enables: - connection between the two power terminals of the same pole for 2000 to 3200 ratings (Fig. 1 and Fig 2). - top or bottom bridging connection (Fig. 3). For 3200 rating, the connection pieces (part ) are delivered bridged from factory. Bolt sets must be ordered separately. Further details for these specific accessories are available in the user guide downloadable from Fig. 1 acces_226_b_1_x_cat Top or bottom flat connection - Fig. 1 Quantity to order Piece per pole (1) Reference Connection - part Bolt set - part B acces_232_a_1_cat 3200 Connection - part included 3200 Bolt set - part B (1) Example for 3 pole device equipped upstream only: Order 3 times the indicated quantities. Top or bottom edgewise connection - Fig. 2 Quantity to order Piece per pole (1) Reference Connection - part T piece - part C (2) Bracket- part D (2) Fig.2 C D acces_228_b_1_x_cat 3200 Connection - part included 3200 T piece - part C (2) 3200 Bracket- part D (2) (1) Example for 3 pole device equipped upstream only: Order 3 times the indicated quantities. (2) Bolt set is provided with the accessories. Top or bottom bridging connection - Fig. 3 Quantity to order Piece per pole (1) Reference Connection - part Bolt set - part B Bar - part E (2) T piece - part C (2) 210 Fig. 3 C E B acces_233_a_1_cat acces_230_b_1_x_cat 3200 Connection - part included 3200 Bolt set - part B Bar - part E (2) 3200 T piece - part C (2) (1) Example for 3 pole device equipped upstream only: Order 3 times the indicated quantities. (2) Bolt set is provided with the accessories acces_234_a_1_cat uxiliary contact Pre breaking and signalling of positions and : 1 or 2 NO/NC auxiliary contacts in each position. Low level auxiliary contacts: Please consult us. NO/NC changeover contact Connection to the control circuit 6.35 mm fast-on terminal. Electrical characteristics operations. Characteristics Operating current e () Nominal VC 24 VDC 48 VDC current () 13 VC C-13 DC-13 DC acces_065_a_1_cat svr_058_a_1_cat Contact(s) Reference st /2 nd st included General Catalogue

9 ccessories (continued) Terminal shrouds Protection against direct contact with terminals or connecting parts. dvantage Perforations allow remote thermographic inspection without the need to remove the shrouds. No. of poles Position Reference top / bottom / front () / rear () (1)(2) top / bottom / front () / rear () (1)(2) top / bottom / front () / rear () (1)(2) top / bottom / front () / rear () (1)(2) top / bottom / front () / rear () (1)(2) top / bottom / front () / rear () (1)(2) (1) To shroud front switch top and bottom 4 references required for a and 6 references for a Bypass. (2) To shroud front switch top and bottom 2 references required for a and a Bypass. acces_206_a_2_cat Terminal screens Top and bottom protection against direct contact with terminals or connection parts. No. of poles Position Reference top / bottom top / bottom top / bottom top / bottom top / bottom top / bottom top / bottom top / bottom top / bottom top / bottom / top / bottom included acces_207_a_2_cat 336 General Catalogue

10 Key handle interlocking system Padlocking in position, 0 or Bypass Operation Figure Reference external Locking using RONS EL11P lock in position 0 (not included) Bypass Operation Figure Reference direct (1) direct lease consult us direct (2) direct (2) external (2) external (2) (1) Specific handle included. (2) This locking facility can be configured by the user in the 3 positions. Locking using RONS EL11P lock in position, 0, (not included) Bypass Operation Figure Reference direct (1) direct lease consult us direct (2) direct (2) external (2) external (2) (1) Specific handle included. (2) This locking facility can be configured by the user in the 3 positions. Using padlock (not supplied).this device is factory mounted in the direct or external operation handle and allows the use of up to 3 padlocks. Locking: - using lock (not supplied) - using undervoltage coil. The interlocking positions are either determined as standard or configured by the user by removing the pre-formed tabs. Padlocking and locking can be combined. Fig. 1 acces_061_a_1_x_cat Fig.2 acces_001_a_1_x_cat Fig. 3 Fig.4 Locking using 230 VC undervoltage coil in position (factory fitted) Bypass Operation Figure Reference direct lease consult us Locking using type K CSTELL lock (not supplied) Bypass Operation Figure Reference external external acces_132_a_1_x_cat acces_158_a_1_x_cat Other specific accessories bd_03_04_01 Customised protection screens (for specific dimensions or high ambient temperatures). nter phase barrier. Connection accessories. Low level auxiliary contacts. General Catalogue

11 C Characteristics according to EC and EC to 630 Thermal current th at 40 C Rated insulation voltage U i (V) Rated impulse withstand voltage U imp (kv) Rated operational currents e () Rated voltage Utilisation category /B (1) /B (1) /B (1) /B (1) /B (1) /B (1) /B (1) /B (1) 415 VC C-20 / C-20 B 125/ / / / / / / / VC C-21 / C-21 B 125/ / / / / / / / VC C-22 / C-22 B 125/ / / / / / / / VC C-23 / C-23 B 125/ / / / / / / / VC C-20 / C-20 B 125/ / / / / / / / VC C-21 / C-21 B 125/ / / / / / / / VC C-22 / C-22 B 125/ / / / / / / / VC C-23 / C-23 B 80/80 80/80 80/80 200/ / / / / VC (7) C-20 / C-20 B 125/ / / / / / / / VC (7) C-21 / C-21 B 125/ / / / / / / / VC (7) C-22 / C-22 B 125/ / / / / / / / VC (7) C-23 / C-23 B 63/80 63/80 63/80 125/ / / / / VDC DC-20 / DC-20 B 125/ / / / / / / / VDC DC-21 / DC-21 B 125/ / / / / / / / VDC DC-22 / DC-22 B 125/ / / / / / / / VDC DC-23 / DC-23 B 125/ / / / / / / / VDC DC-20 / DC-20 B 125/ / / / / / / / VDC DC-21 / DC-21 B 125 (2) /125 (2) 125 (2) /125 (2) 125 (2) /125 (2) 200 (2) /200 (2) 200 (2) /200 (2) 200 (2) /200 (2) 500 (2) /500 (2) 630 (2) /630 (2) 440 VDC DC-22 / DC-22 B 125 (2) /125 (2) 125 (2) /125 (2) 125 (2) /125 (2) 200 (2) /200 (2) 200 (2) /200 (2) 200 (2) /200 (2) 500 (2) /500 (2) 630 (2) /630 (2) 440 VDC DC-23 / DC-23 B 125 (3) /125 (3) 125 (3) /125 (3) 125 (3) /125 (3) 200 (3) /200 (3) 200 (3) /200 (3) 200 (3) /200 (3) 500 (3) /500 (3) 500 (3) /500 (3) Operational power in C-23 (kw) t 400 VC without pre-break in C (3) 63/63 80/80 80/80 132/ / / / /450 t 690 VC without pre-break in C (3) 55/75 55/75 55/75 90/110 90/ / / /220 Reactive power (kvar) t 400 VC (5) Rated operational currents e () according to EC Rated voltage Utilisation category /B (1) /B (1) /B (1) /B (1) /B (1) /B (1) /B (1) /B (1) 415 VC C-31 / C-31 B VC C-32 / C-32 B VC C-33 / C-33 B Fuse protected short-circuit withstand as per EC at 690 VC Prospective short-circuit current (k rms) 100 (5) 100 (5) 50 (5) ssociated fuse rating () Circuit breaker protected short-circuit withstand with any circuit breaker that ensures tripping in less than 0.3s (4) Rated short-time withstand current 0.3s cw (k rms) 12 (5) 12 (5) 12 (5) Short-circuit withstand without protection as per EC at 690 VC Rated short-time withstand current 1s cw (k rms) 7 (5) 7 (5) 7 (5) Rated short-circuit making capacity cm (k peak) Rated short-time withstand current 60ms cw (k rms) as per EC at 415 VC 10 (6) 10 (6) 10 (6) Connection Minimum Cu cable cross-section (mm 2 ) x 150 Minimum Cu busbar cross-section (mm 2 ) 2 x 30 x 5 Maximum Cu cable cross-section (mm 2 ) x x 300 Maximum Cu busbar width (mm) Tightening torque mini / maxi (Nm) 9/13 9/13 9/13 20/26 20/26 20/26 20/26 20/26 Mechanical characteristics Durability (number of operating cycles) Weight of switch (kg) Weight of switch (kg) (1) Category with index = frequent operation - Category with index B = infrequent operation. (2) 3-pole device with 2 pole in series for the "+" and 1 pole for the "-".4-pole device with 2 pole in series by polarity. (3) The power value is given for information only, the current values vary from one manufacturer to another. (4) Value for coordination with any circuit breaker that ensures tripping in less than 0.3s. For coordination with specific circuit-breaker references, higher short-circuit current values are available. Please consult us. (5) Data at 415 VC (6) Data at 30 ms (7) With terminal shrouds or phase barrier. 338 General Catalogue

12 800 to 3200 Thermal current th at 40 C Rated insulation voltage U i (V) Rated impulse withstand voltage U imp (kv) Rated operational currents e () Rated voltage Utilisation category /B (1) /B (1) /B (1) /B (1) /B (1) /B (1) /B (1) 415 VC C-20 / C-20 B 800/ / / / / / / VC C-21 / C-21 B 800/ / / /1600 -/2000 -/2500 -/ VC C-22 / C-22 B 800/ / / /1600 -/2000 -/2500 -/ VC C-23 / C-23 B 800/ / / /1250 -/1600 -/1600 -/ VC C-20 / C-20 B 800/ / / / / / / VC C-21 / C-21 B 800/ / / /1600 -/2000 -/2500 -/ VC C-22 / C-22 B 630/ / / / VC C-23 / C-23 B 400/ / / / VC (6) C-20 / C-20 B 800/ / / / / / / VC (6) C-21 / C-21 B 800/ / / /1600 -/2000 -/2500 -/ VC (6) C-22 / C-22 B 630/ / / / VC (6) C-23 / C-23 B 400/ / / / VDC DC-20 / DC-20 B 800/ / / / VDC DC-21 / DC-21 B 800/ / / / VDC DC-22 / DC-22 B 800/ / / / VDC DC-23 / DC-23 B 800/ / / / VDC DC-20 / DC-20 B 800/ / / / VDC DC-21 / DC-21 B 800 (3) /800 (3) 1000 (3) /1000 (3) 1250 (3) /1250 (3) 1250/ VDC DC-22 / DC-22 B 800 (3) /800 (3) 1000 (3) /1000 (3) 1250 (3) /1250 (3) 1250/ VDC DC-23 / DC-23 B 800 (3) /800 (3) 1000 (3) /1000 (3) 1250 (3) /1250 (3) 1250/1250 Operational power in C-23 (kw) t 400 VC without pre-break in C (3) 710/ / / / /710 t 690 VC without pre-break in C (3) 185/ / / / /750 Reactive power (kvar) t 400 VC (5) Rated operational currents e () according to EC Rated voltage Utilisation category /B (1) /B (1) /B (1) /B (1) /B (1) /B (1) /B (1) 415 VC C-31 / C-31 B VC C-32 / C-32 B VC C-33 / C-33 B Fuse protected short-circuit withstand as per EC at 415 VC Prospective short-circuit current (k rms) ssociated fuse rating () x 800 Circuit breaker protected short-circuit withstand with any circuit breaker that ensures tripping in less than 0.3s (4) Rated short-time withstand current 0.3s cw (k rms) Short-circuit withstand without protection as per EC at 415 VC Rated short-time withstand current 1s cw (k rms) Rated short-circuit making capacity cm (k peak) Rated short-time withstand current 60ms cw (k rms) as per EC at 415 VC Connection Minimum Cu cable cross-section (mm 2 ) 2 x x 240 Minimum Cu busbar cross-section (mm 2 ) 2 x 40 x 5 2 x 50 x 5 2 x 60 x 5 2 x 80 x 5 2 x 100 x 10 2 x 100 x 10 2 x 100 x 10 Maximum Cu cable cross-section (mm 2 ) 2 x x x x 185 Maximum Cu busbar width (mm) Tightening torque min (Nm) 20/26 20/26 20/26 40/45 40/45 40/45 40/45 Mechanical characteristics Durability (number of operating cycles) Weight of switch (kg) Weight of switch (kg) (1) Category with index = frequent operation - Category with index B = infrequent operation. (2) 3-pole device with 2 pole in series for the "+" and 1 pole for the "-".4-pole device with 2 pole in series by polarity. (3) The power value is given for information only, the current values vary from one manufacturer to another. (4) Value for coordination with any circuit breaker that ensures tripping in less than 0.3s. For coordination with specific circuit-breaker references, higher short-circuit current values are available. Please consult us. (5) Data at 415 VC. (6) With terminal shrouds or phase barrier. General Catalogue

13 -+ - and Bypass - Characteristics according to EC to 400 Thermal current th at 40 C Rated insulation voltage U i (V) Rated impulse withstand voltage U imp (kv) Rated operational currents e () Rated voltage Utilisation category /B (1) /B (1) /B (1) /B (1) /B (1) 415 VC C-20 / C-20 B 125/ / / / / VC C-21 / C-21 B 125/ / / / / VC C-22 / C-22 B 125/ / / / / VC C-23 / C-23 B 125/ / / / / VC (2) C-20 / C-20 B 125/ / / / / VC (2) C-21 / C-21 B 125/ / / / / VC (2) C-22 / C-22 B 125/ / / / / VC (2) C-23 / C-23 B 63/80 63/80 63/80 100/ / VDC DC-20 / DC-20 B 125/ / / / / VDC DC-21 / DC-21 B 125/ / / / / VDC DC-22 / DC-22 B 125/ / / / / VDC DC-23 / DC-23 B 125/ / / / / VDC DC-20 / DC-20 B 125/ / / / / VDC DC-21 / DC-21 B 125 (3) /125 (3) 125 (3) /125 (3) 125 (3) /125 (3) 200 (3) /200 (3) 200 (3) /200 (3) 440 VDC DC-22 / DC-22 B 125 (3) /125 (3) 125 (3) /125 (3) 125 (3) /125 (3) 200 (3) /200 (3) 200 (3) /200 (3) 440 VDC DC-23 / DC-23 B 125 (4) /125 (4) 125 (4) /125 (4) 125 (4) /125 (4) 200 (4) /200 (4) 200 (4) /200 (4) Operational power in C-23 (kw) t 400 VC without pre-break in C (1)(5) 63/63 80/80 80/80 132/ /132 t 690 VC without pre-break in C (1)(5) 55/75 55/75 55/75 90/110 90/110 Reactive power (kvar) t 400 VC (5) Fuse protected short-circuit withstand as per EC at 400 VC Prospective short-circuit current (k rms) ssociated fuse rating () Circuit breaker protected short-circuit withstand with any circuit breaker that ensures tripping in less than 0.3s (6) Rated short-time withstand current 0.3s cw (k rms) Short-circuit capacity (without protection) Rated short-time withstand current 1s cw (k rms) Connection Minimum Cu cable cross-section (mm 2 ) Minimum Cu busbar cross-section (mm 2 ) Maximum Cu cable cross-section (mm 2 ) Maximum Cu busbar width (mm) Tightening torque min (Nm) Mechanical characteristics Durability (number of operating cycles) Weight of switch (kg) Weight of switch (kg) (1) Category with index = frequent operation - Category with index B = infrequent operation. (2) With terminal shrouds or phase barrier. (3) 4-pole device with 2 poles in series per polarity. (4) 3-pole device with 2 pole in series for the "+" and 1 pole for the "-". (5) The power value is given for information only, the current values vary from one manufacturer to another. (6) Value for coordination with any circuit breaker that ensures tripping in less than 0.3s. For coordination with specific circuit-breaker references, higher short-circuit current values are available. Please consult us. 340 General Catalogue

14 500 to 1800 Thermal current th at 40 C Rated insulation voltage U i (V) Rated impulse withstand voltage U imp (kv) Rated operational currents e () Rated voltage Utilisation category /B (1) /B (1) /B (1) /B (1) /B (1) /B (1) 415 VC C-20 / C-20 B 500/ / / / / / VC C-21 / C-21 B 500/ / / / / / VC C-22 / C-22 B 500/ / / / / / VC C-23 / C-23 B 500/ / / / / / VC (2) C-20 / C-20 B 500/ / / / / / VC (2) C-21 / C-21 B 400/ / / / / / VC (2) C-22 / C-22 B 250/ / / / / / VC (2) C-23 / C-23 B 160/ / / / / / VDC DC-20 / DC-20 B 500/ / / / / / VDC DC-21 / DC-21 B 500/ / / / / / VDC DC-22 / DC-22 B 400/ / / / / / VDC DC-23 / DC-23 B 400/ / / / / / VDC DC-20 / DC-20 B 500/ / / / / / VDC DC-21 / DC-21 B 400 (3) /400 (3) 500 (3) /500 (3) 800 (4) /800 (4) 1250 (4) /1250 (4) 1250 (4) /1250 (4) 1250 (4) /1250 (4) 440 VDC DC-22 / DC-22 B 315 (3) /400 (3) 500 (3) /500 (3) 800 (4) /800 (4) 1250 (4) /1250 (4) 1250 (4) /1250 (4) 1250 (4) /1250 (4) 440 VDC DC-23 / DC-23 B 400 (4) /400 (4) 500 (4) /500 (4) 800 (4) /800 (4) 1250 (4) /1250 (4) 1250 (4) /1250 (4) 1250 (4) /1250 (4) Operational power in C-23 (kw) t 400 VC without pre-break in C (1)(5) 280/ / / / / /710 t 690 VC without pre-break in C (1)(5) 150/ / / / / /475 Reactive power (kvar) t 400 VC (5) Fuse protected short-circuit withstand as per EC at 400 VC Prospective short-circuit current (k rms) ssociated fuse rating () x x 800 Circuit breaker protected short-circuit withstand with any circuit breaker that ensures tripping in less than 0.3s (6) Rated short-time withstand current 0.3s cw (k rms) Short-circuit capacity (without protection) Rated short-time withstand current 1s cw (k rms) Connection Minimum Cu cable cross-section (mm 2 ) x x 185 Minimum Cu busbar cross-section (mm 2 ) 2 x 30 x 5 2 x 40 x 5 2 x 60 x 5 2 x 80 x 5 2 x 80 x 5 Maximum Cu cable cross-section (mm 2 ) x x x x 185 Maximum Cu busbar width (mm) Tightening torque min (Nm) Mechanical characteristics Durability (number of operating cycles) Weight of switch (kg) Weight of switch (kg) (1) Category with index = frequent operation - Category with index B = infrequent operation. (2) With terminal shrouds or phase barrier. (3) 4-pole device with 2 poles in series per polarity. (4) 3-pole device with 2 pole in series for the "+" and 1 pole for the "-". (5) The power value is given for information only, the current values vary from one manufacturer to another. (6) Value for coordination with any circuit breaker that ensures tripping in less than 0.3s. For coordination with specific circuit-breaker references, higher short-circuit current values are available. Please consult us. General Catalogue

15 Dimensions 125 to1800 Direct front operation External front operation 10 M Z Z1 U W 8.5 Y Y 1 B C B C 0 N V C 3p. Overall dimensions 4p. C E min C H H Terminal shrouds Switch body Switch mounting Connection J 3p. J 4p. M 3p. M 4p. N T U V W X 3p. X 4p. Y Z Z1 B C x x x to 3200 Direct front operation M L1 125 X T T J T H C 18 svr_072_i_1_x_cat H E min. H S2 type handle for external operation: 125 to 630 B. S4 type handle for external operation: 800 to Terminal shrouds 2. Direct handle operation: to 630 : L1 = 140 mm, to 1800 : L1 = 210 mm svr_150_a_1_x_cat Overall dimensions Switch mounting 3p. 4p. M 3p. M 4p General Catalogue

16 Direct front operation 10 C U M W 8.5 Z Z1 Z2 Y Y Y 1 V 2 C C B L1 External front operation H 45 Overall dimensions Terminal shrouds Switch body Switch mounting Connection M Rating E J 3+6 J 4+8 M X X () 3+6p. 4+8p. C min C H H p. p. p. p. N T U V W 3+6p. 4+8p. Y Z Z1 Z1 B C x x Connection terminals and Bypass 800 and Bypass to 3200 Bypass 1600 ø 9 16 x 11 ø Bypass 125 to N X T T J T H C 18 svr_070_i_1_x_cat H 125 B 210 C 330 = =. S2 type handle for external operation: 125 to 200 B. S3 type handle for external operation: 250 to 630 C. External double lever handle: 800 to Terminal shrouds 2. Direct handle operation: to 200 : L1 = 140 mm, to 630 : L1 = 210 mm, to 1600 : L1 = Ø 330 mm. E min ø svr_077_a_1_x_cat svr_078_b_1_x_cat svr_098_a_1_x_cat General Catalogue

17 Dimensions for external handles 125 to 630 Front operation Handle type S2 type Ø Direction of operation 0 or + Ø D (1) Door drilling RONS EL11P Ø 26 4 Ø Ø CSTELL K poign_030_a_1_gb_cat (1) Ø31 to Ø37: Rear screw mounting Ø37: front clip mounting. 800 to1800 Front operation Handle type S4 type Ø78 Direction of operation 0 or + (2) Door drilling RONS EL11P Ø 26 4 Ø CSTELL K 2 Ø Ø D (1) poign_031_a_1_gb_cat (1) Ø31 to Ø37: Rear screw mounting Ø37: front clip mounting. (2) Ø6 to Ø7: clip mounting to 3200 Handle type Front operation Direction of operation Door drilling S5 type with V Escutcheon CSTELL K Ø 6, Ø x Ø 6.5 Ø 31 3 x Ø 6.5 poign_023_a_1_gb_cat General Catalogue

18 Bypass 125 to 200 Front operation Handle type S2 type Direction of operation 0 Door drilling RONS EL11P CSTELL K Ø Ø D (1) Ø 5.5 Ø Ø poign_032_a_1_gb_cat (1) Ø31 to Ø37: Rear screw mounting Ø37: front clip mounting. Bypass 250 to 630 Front operation Handle type S3 type Direction of operation 0 Door drilling RONS EL11P CSTELL K Ø Ø D (1) Ø 26 4 Ø Ø poign_033_a_1_gb_cat (1) Ø31 to Ø37: Rear screw mounting Ø37: front clip mounting. Bypass 800 to 1600 Front operation Handle type C type Direction of operation 4 Ø Door drilling CSTELL K Ø x Ø 6.5 Ø 31 3 x Ø 6.5 poign_022_a_1_gb_cat General Catalogue

FUSERBLOC. 20 to 1250 A Manual operation. 142 General Catalogue 2011-2012 SOCOMEC. Fuse combination switches

FUSERBLOC. 20 to 1250 A Manual operation. 142 General Catalogue 2011-2012 SOCOMEC. Fuse combination switches FUSERBLOC Fuse combination switches appli_8_a fuser_548_a cat fuser_59_a cat fuser_52_a cat 2 to 25 A Manual operation Function FUSERBLOC are manually operated multipolar fuse combination switches. They

More information

Low Voltage Products. Switches Automatic Transfer Switches

Low Voltage Products. Switches Automatic Transfer Switches Low Voltage Products Switches Automatic Transfer Switches Growing importance of a secure power supply Standby power is an integral part of many industrial and domestic electrical systems. High energy prices,

More information

R.C.C.B. s two-pole LEXIC

R.C.C.B. s two-pole LEXIC 87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s two-pole LEXIC 089 06/09/10/11/12/15/16/17/18/ 27/28/29/30/35, CONTENTS PAGES 1. Electrical and mechanical characteristics...

More information

Manual motor starter MS116

Manual motor starter MS116 Data sheet Manual motor starter MS116 Manual motor starters are electromechanical devices for motor and circuit protection. These devices offer local motor disconnect means, manual ON/ OFF control, and

More information

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV.00 2012.4

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV.00 2012.4 CE - BF - C - en - REV.00 2012.4 APPLICATION CE-BF Switchbords up to 40.5 kv are designed for use in public and industrial distribution system up to 40,5KV for the operation and protection of lines, transformers,

More information

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil Product data sheet Characteristics LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application. Low voltage Direct Current Network Compact NSX DC PV Circuit breakers and switch disconnectors for solar application Catalogue 2012 Compact NSX DC PV A complete DC offer for solar application from 80

More information

GE Power Controls. MiniFORM Switchboards

GE Power Controls. MiniFORM Switchboards GE Power Controls MiniFORM Switchboards MiniFORM MiniFORM MiniFORM switchboards Arrangement Modules Arrangement modules 1-6 6 Arrangement modules 7-12 7 Arrangement modules 12-14 8 Arrangement modules

More information

Breakers and Switches. Switches Switch-disconnectors OT, OETL, OTDC and OTM

Breakers and Switches. Switches Switch-disconnectors OT, OETL, OTDC and OTM Breakers and Switches Switches Switch-disconnectors OT, OETL, OTDC and OTM Switch-disconnectors OT 16...2500, OETL 3150, OTDC16...32 and OTM160...2500 Contents 4 Product overview, features 8 Technical

More information

Electronic overload relay EF19 and EF45

Electronic overload relay EF19 and EF45 Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor

More information

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN 60204-1, VDE 0113 Part 1

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN 60204-1, VDE 0113 Part 1 MainswitchSurfacemounting Partno. P3-63/I4/SVB Articleno. 207343 CatalogNo. SP3-063-I4CRQ IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual

More information

Type-Tested Power Distribution Board 8PT with Rear Busbars. sivacon

Type-Tested Power Distribution Board 8PT with Rear Busbars. sivacon Type-Tested Power Distribution Board 8PT with Rear Busbars sivacon The Obvious Solution for Global Challenges SIVACON Type-testing is one of today s important issues for low-voltage technology and will

More information

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101433D0201 28/03/11 NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits.

More information

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance SPECIFICATION FOR LOW VOLTAGE SWITCHBOARD SEN I N D E X Description 10 STANDARD TECHNICAL REQUIREMENTS 11 Standards 12 General Operating Conditions 13 General Description Of Switchboard 131 Structure 132

More information

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils

More information

Thermal-Magnetic Circuit Breaker 3120-...-M1-..

Thermal-Magnetic Circuit Breaker 3120-...-M1-.. Thermal-Magnetic Circuit Breaker -...-M-.. Description Single or two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 34). The addition of a magnetic tripping

More information

AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101403D0201 24/03/11 AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF09(Z) contactors are used for controlling power circuits

More information

48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0.

48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0. 48 Series - Relay interface modules 8 A Features 48.12 2 Pole Safety relay interface modules, 15.8 mm wide 48.12-2 Pole 8 A (screw terminal) DC sensitive coils Relay with forcibly guided contacts according

More information

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors PRODUCT GUIDE SL Medium Voltage IEC Vacuum Contactors Table of Contents 1 Overview Introduction....................................................2 Features........................................................2

More information

Electronic overload relay EF65, EF96 and EF146

Electronic overload relay EF65, EF96 and EF146 Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays.

More information

Plug and Socket Devices CES 63 A Series 8579

Plug and Socket Devices CES 63 A Series 8579 www.stahl.de > Switch socket / plug 63 A > Large switch handle with clear switch position indication padlockable in 0- and I-position > Low insertion and withdrawal forces through individually encapsulated

More information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2... Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast

More information

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51 34 Series - Slim electromechanical PCB relays 6 34 SERIES Features 34.51 Ultra-slim 1 Pole - 6 relay Printed circuit mount - direct or via PCB socket 35 mm rail mount - via screw, screwless or push-in

More information

UniGear ZS1. Medium voltage, arc proof, air insulated switchgear for primary distribution

UniGear ZS1. Medium voltage, arc proof, air insulated switchgear for primary distribution UniGear ZS1 Medium voltage, arc proof, air insulated switchgear for primary distribution UniGear ZS1: an innovative solution for all installation requirements ABB UniGear is medium voltage metal-clad,

More information

Type: DILM9 10(24VDC) Article No.: 276705

Type: DILM9 10(24VDC) Article No.: 276705 Type: DILM9 10(24VDC) Article No.: 276705 Ordering information Rated operational current AC 3 400 V I e A 9 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors, 50

More information

Contractors Guide Central Inverter System Installation

Contractors Guide Central Inverter System Installation Contractors Guide Central Inverter System Installation Step By Step Procedures 2,200 Watt/VA 6 Step Installation 1. Mount Bottom Cabinet 2. Mount Top Cabinet 3. Install Batteries 4. Install Conduit 5.

More information

Tmax MCCBs. Molded case circuit breakers. Tmax

Tmax MCCBs. Molded case circuit breakers. Tmax Molded case circuit breakers Introduction ABB is once again demonstrating its commitment to new product development and its superiority in product performance. Never before has the industry seen such high

More information

Renewable energy. Inverters - Socomec G-1. Load break switches (Isolators) - Socomec G-2. Fuses - df G-3. Fuse bases.

Renewable energy. Inverters - Socomec G-1. Load break switches (Isolators) - Socomec G-2. Fuses - df G-3. Fuse bases. G Product page Inverters - Socomec G-1 Load break switches (Isolators) - Socomec G-2 Fuses - df G-3 Fuse bases Surge protection - df G-3 - Wohner G-5 - CPT G-4 - Dehn G-5 Connectors - Wieland G-6 Cable

More information

48 SERIES Relay interface modules 10 A

48 SERIES Relay interface modules 10 A 48 Relay interface modules 10 A 1 CO relay interface modules, mm wide Ideal interface for PLC and electronic systems Type 48.P3 1 CO 10 A s Type 48.31 1 CO 10 A s AC coils or DC sensitive coils Supply

More information

49 Series - Relay interface modules 8-10 - 16 A. Features

49 Series - Relay interface modules 8-10 - 16 A. Features Features 1 & 2 Pole relay interface modules 5 µm Gold plate contacts for low level switching capability 49.31-50x0-1 Pole 10 A (screw terminal) 49.52-50x0-2 Pole 8 A (screw terminal) 49.72-50x0-2 Pole

More information

SENTRON Switching and Protection Devices Air Circuit Breakers

SENTRON Switching and Protection Devices Air Circuit Breakers Siemens AG 9 SENTRON Switching and rotection Devices Air Circuit reakers 5 5/ Introduction 3WL Air Circuit reakers 3WL Air Circuit reakers/ Non-Automatic Air Circuit reakers up to 63 A (AC) 5/6 General

More information

Givare NC-SRS 280 och 880

Givare NC-SRS 280 och 880 Givare NC-SRS 280 och 880 Aratron AB/Nordic Control, 02 03 SRS280SEALED ROTARY SENSOR PERFORMANCE ±2 Resistance ±20% Hysteresis (repeatability) Accuracy Applied voltage maximum Resolution Output smoothness

More information

Type: DILM32 10(24V50HZ) Article No.: 277247

Type: DILM32 10(24V50HZ) Article No.: 277247 Type: DILM32 10(24V50HZ) Article No.: 277247 Ordering information Rated operational current AC 3 400 V I e A 32 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors,

More information

Catalogue May 2015. EasyLine XLP Fuse Switch Disconnector 1-2-3-4 pole

Catalogue May 2015. EasyLine XLP Fuse Switch Disconnector 1-2-3-4 pole Catalogue May 2015 EasyLine XLP Fuse Switch Disconnector 1-2-3-4 pole Contents Introduction 1 Overview 1-pole 2 Overview 2-pole 3 Overview 3-pole 4 Overview 4-pole 5 Electronic Fuse Monitoring 6 Busbar

More information

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES BUSHING WITH PLUG CONNECTION WITH OUTER CONE PPS CHARACTERISTICS The PPS bushing can be used as a fixed section for the entry of medium

More information

Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830

Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830 Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830 Ordering information Rated operational current AC 3 400 V I e A 50 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase

More information

Single and three phase modular Automatic Transfer Switch from 40 to 160 A

Single and three phase modular Automatic Transfer Switch from 40 to 160 A NEW SINGLE PHASE Single and three phase modular Automatic Transfer Switch from 40 to 160 A SWITCH TO INNOVATION SOCOMEC: intelligent changeover systems As a worldwide leading company in changeover power

More information

The complete range of consumer switchboards and switchgear

The complete range of consumer switchboards and switchgear Power Distribution The complete range of consumer switchboards and switchgear www.nhp.com.au/mod6 The MOD6 range of consumer switchboards and switchgear is specifically designed for domestic and commercial

More information

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description Photoelectrics, Background Suppression reflective with IR light Main features Description The PD30ET... stainless steel sensors are built with high-quality materials and designed for harsh environments.

More information

Breaking and protection devices

Breaking and protection devices Breaking and protection devices 05 POWER GUIDE 2009 / BOOK 05 INTRO The purpose of selecting a protection device is to perform two essential functions: to protect people and to protect trunking, while

More information

Safety detection solutions

Safety detection solutions Presentation, actuator operated etal, types CS A, CS B, CS C and CS E Plastic, double insulated, turret head, types CS P or CS PA or CS TA and CS TE etal, types CS A, CS B, CS C, CS E with or without locking

More information

Breakers and Switches. Switches Change-over, bypass and transfer switches

Breakers and Switches. Switches Change-over, bypass and transfer switches Breakers and Switches Switches Change-over, bypass and transfer switches Change-over, bypass and transfer switches Product overview, features Product overview 4 Features 6 Technical data Manual / motorized

More information

Rotary Disconnect Switch Specifications

Rotary Disconnect Switch Specifications Technical Data Rotary Disconnect Switch Specifications Bulletin Number 194R Topic Page Product Line Overview 2 General Specifications Fuse Description 12 Approximate Dimensions 14 Additional Resources

More information

Unified requirements for systems with voltages above 1 kv up to 15 kv

Unified requirements for systems with voltages above 1 kv up to 15 kv (1991) (Rev.1 May 2001) (Rev.2 July 2003) (Rev.3 Feb 2015) Unified requirements for systems with voltages above 1 kv up to 15 kv 1. General 1.1 Field of application The following requirements apply to

More information

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display

More information

Technical catalogue. Modular DIN rail components Installation contactors

Technical catalogue. Modular DIN rail components Installation contactors Technical catalogue Modular DIN rail components Installation contactors Installation Contactors Overview... ESB Installation Contactors 0 A / AC-/AC-7a ESB0...4 4 A / AC-/AC-7a ESB4...5 40 A / AC-/AC-7a

More information

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only

More information

Bimetallic Overload Relay Specifications

Bimetallic Overload Relay Specifications Technical Data Bimetallic Overload Relay Specifications Bulletin Number 193K, 193T1 Topic Page Product Overview 2 Standards compliance and Certifications 2 General Specifications 193K 3 Approximate Dimensions

More information

METAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV. tgood.com. Energy. Fast.

METAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV. tgood.com. Energy. Fast. METAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV tgood.com Energy. Fast. TGOOD produces over 5000 switchgear units annually for projects around the globe PRODUCT OVERVIEW Integral substation component

More information

Bussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1

Bussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1 How to configure Part Numbers: Step : Select Switch Amperage Power Module Switch Rating (Amps) Power Module Switch Catalog No. 30 3 60 6 00 200 2 400 4 Step 2: Select Options Needed 5 Bussmann Power Module

More information

Application Switchgear for industrial and commercial applications. U e V AC 230/400. 48 (per pole)

Application Switchgear for industrial and commercial applications. U e V AC 230/400. 48 (per pole) Overcurrentswitch,6A,2p,D-Char,AC Partno. FAZ-D6/2 Articleno. 278777 CatalogNo. FAZ-D6/2 Similar to illustration Deliveryprogramme Basic function Miniature circuit breakers Pole 2 pole Tripping characteristic

More information

Technical data UNIBLOCK UBSF 180 625

Technical data UNIBLOCK UBSF 180 625 Data TECHNICL DT Technical data UNIBLOCK UBSF 80 6 Output data Type UBSF 80 UBSF 0 UBSF 00 UBSF 6 Output power 80 kv 0 kv 00 kv 6 kv Output voltage 80/77 V 0/ V 0/ V 0/ V Output current 7 8 66 80 Power

More information

Molded Case Circuit Breaker Specifications Bulletin Number 140U-D

Molded Case Circuit Breaker Specifications Bulletin Number 140U-D Technical Data Molded Case Circuit Breaker Specifications Bulletin Number 140U-D Topic Page Product Line Overview 2 Specifications 3 Trip Curves 4 Approximate Dimensions 6 Additional Resources These documents

More information

Selector Switch Type 08

Selector Switch Type 08 Compact and versatile 2 positions multi wafer selector switch For PCB mounting 25,000 switching cycles with up to 9.0 Ncm switching torque Gold plated contacts: micron Robust metal housing with metal shaft

More information

Technicaldata General

Technicaldata General Currenttransformer-operatedoverloadrelay,60-90A,1N/O+1N/C Partno. ZW7-90 Articleno. 002618 CatalogNo. XTOT090C3S Deliveryprogramme Product range ZW7 current transformer-operated overload relays Description

More information

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

Submit shop drawings for equipment provided under this section Shop drawings shall indicate: Section 16435 - SWITCHBOARDS Introduction Part 1 - General Reference The work under this section is subject to requirements of the Contract Documents including the General Conditions, Supplementary Conditions,

More information

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage

More information

P System Cubicles. Certified for more safety

P System Cubicles. Certified for more safety P System Cubicles Prisma Plus LV Switchboards Certified for more safety Prisma Plus, an offer thought out for greater professionalism With the Prisma Plus P system, Schneider Electric proposes high-performance

More information

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection Technical Data Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection Topic Page 1489-M Miniature Circuit Breakers 2 1492-SP Supplementary Protectors 15 1492-D Circuit Breakers 27 188 Regional

More information

SIVACON The Versatile Low-Voltage Switchboard

SIVACON The Versatile Low-Voltage Switchboard s SIVACON The Versatile Low-Voltage Switchboard Type-Tested Power Distribution Board 8PT The Obvious Solution for Global Challenges SIVACON Type testing in low-voltage switchgear is increasingly becoming

More information

NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems. Safe energy distribution that meets the highest industrial requirements

NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems. Safe energy distribution that meets the highest industrial requirements NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems Safe energy distribution that meets the highest industrial requirements NATUS switchgear systems your advantages minimal use of insulant

More information

Breakers and Switches. Switches Automatic Transfer Switches

Breakers and Switches. Switches Automatic Transfer Switches Breakers and Switches Switches Automatic Transfer Switches Growing importance of a secure power supply ABB s range of automatic transfer switches goes from 160 to 1600 Amperes. There are three types of

More information

RY2 miniature industrial relays

RY2 miniature industrial relays 6 RY2 Relays of general application For plug-in sockets, 35 mm rail mount acc. to PN-EN 60715 or on panel mounting Flat insert connectors - faston x 0,5 mm Recognitions, certifications, directives: RoHS,

More information

Catalog. Modular DIN rail components Installation contactors

Catalog. Modular DIN rail components Installation contactors Catalog Modular DIN rail components Installation contactors 0 CDC00C00 Installation contactors Benefits and features Overview Ordering details ESB installation contactors ESB0 ESB ESB0 ESB 7 EN installation

More information

Vario-Series Accessories

Vario-Series Accessories Accessories and spare parts for GMW analogue panel meters and controllers Current Transformers pages 2-9 Shunt Resistors 10-11 Voltage Dividers 12 Power supply for indicator/controllers 13 Blanking Plates

More information

CAS 36 Ring Main Unit

CAS 36 Ring Main Unit Power distribution networks Ring Main Unit Catalogue 2008 A new path for achieving your electrical installations A comprehensive offer The range is part of a comprehensive offer of products that are perfectly

More information

Three-phase monitoring relay CM-PFE

Three-phase monitoring relay CM-PFE Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics

More information

ST Series POWER SUPPLIES USER INSTRUCTIONS

ST Series POWER SUPPLIES USER INSTRUCTIONS Introduction These instructions detail the installation and operation requirements for the ST20 & ST35 power supplies. These have been designed for operation in RV s providing a DC power system, with optional

More information

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of

More information

Motor circuit-breakers

Motor circuit-breakers Thermal-magnetic motor circuit-breakers type GV2-M GV2-M Thermal-magnetic motor circuit-breakers GV2-M Pushbutton control Standard power ratings Setting Magnetic Thermal Reference Weight of 3-phase motors

More information

Circuit Breakers. NRC Series. NRC Series. 900 www.idec.com

Circuit Breakers. NRC Series. NRC Series. 900 www.idec.com Switches & Pilot Lights Display Lights NRC series circuit breakers offer circuit protection which is far superior to using fuses in applications containing relay circuits, motor circuits, heater circuits,

More information

Technical catalog - Edition 2015. SACE Tmax PV Adaptability, versatility and complete freedom continue

Technical catalog - Edition 2015. SACE Tmax PV Adaptability, versatility and complete freedom continue Technical catalog - Edition 205 SCE Tmax PV daptability, versatility and complete freedom continue SCE Tmax PV automatic molded case circuit-breakers and molded case switch-disconnectors The Tmax PV line

More information

Our brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy

Our brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy Our brand A strong brand for strong products: The ENERGOLINE brand represents our product portfolio of INDUSTRIAL SWITCHGEAR SYSTEMS. Our products are characterized by a high degree of safety, flexibility

More information

OTM_F_C_. Installation instruction 34OTM_F_C_ / 1SCC303009M0201

OTM_F_C_. Installation instruction 34OTM_F_C_ / 1SCC303009M0201 Change-over Motorized change-over switches switches _F_C_ Installation instruction 4_F_C_ / SCC0009M00 Installation instruction, _F_C_ Contents Mounting and dimensional drawings... 4 Mounting positions...

More information

TriLine ASSEMBLY System PowerModules

TriLine ASSEMBLY System PowerModules 04 2012 TriLine ASSEMBLY System PowerModules TriLine ASSEMBLY system Contents Introduction The new modular system intelligence 2 Delivery formats 8 EDS PowerCon configuration software 10 Technical specifications

More information

IZM ACB/Circuit-breakers. Robust safety. Extract from Main Catalogue HPL2010 IZM26 Circuit-breakers IN26 Switch-disconnectors

IZM ACB/Circuit-breakers. Robust safety. Extract from Main Catalogue HPL2010 IZM26 Circuit-breakers IN26 Switch-disconnectors IZM ACB/Circuit-breakers Robust safety Extract from Main Catalogue HPL2010 IZM26 Circuit-breakers IN26 Switch-disconnectors t [s] 0.1 0.05 0.04 0.03 0.02 0.01 20 1230DIA-125 (70C1043) 30 40 50 60 80 100

More information

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

Voltage Regulator SPAU 341 C. Product Guide

Voltage Regulator SPAU 341 C. Product Guide Issued: July 1998 Status: Updated Version: D/25.04.2006 Data subject to change without notice Features Comprehensive voltage regulation for power transformers with on-load tapchangers in distribution substations

More information

BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview

BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview BETA Switching Siemens AG 200 5TT5 Insta contactors, AC technology Overview The 5TT5 Insta contactors are equipped with an AC magnetic system and are ideal for use under harsh conditions. The auxiliary

More information

Series 8146/5-V37 and Series 8150/5-V37

Series 8146/5-V37 and Series 8150/5-V37 www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection

More information

WE-350 Series ¼ Turn Electric Actuator

WE-350 Series ¼ Turn Electric Actuator WE-350 Series ¼ Turn Electric Actuator Operation and Installation Manual Pg 1 (Rev. 020113) Table of Contents 1.0 General 1.1 Pre-Installation Inspection 1.2 Storage 1.3 Features & General Information

More information

Circuit Breakers. Next Generation of Protection Capabilities

Circuit Breakers. Next Generation of Protection Capabilities Circuit Breakers Next Generation of Protection Capabilities Circuit Breaker Offering Rockwell Automation offers a full line of Allen-Bradley circuit breakers and motor protection devices to help meet many

More information

Medium Voltage Products. ZN1 12 kv arc-proof air-insulated switchgear for primary distribution

Medium Voltage Products. ZN1 12 kv arc-proof air-insulated switchgear for primary distribution Medium Voltage Products ZN1 12 kv arc-proof air-insulated switchgear for primary distribution ZN1 an innovative switchgear for power distribution requirements ABB ZN1 primary distribution switchgear is

More information

Low Voltage Switchboards The Best Technical Solution for Your Ship

Low Voltage Switchboards The Best Technical Solution for Your Ship The Best Technical Solution for Your Ship Wärtsilä SAM Electronics Optimal Power Distribution The uninterrupted supply of power to systems and consumers onboard modern ships is an extremly important matter.

More information

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical

More information

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) Data sheet Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) The temperature monitoring relays CM-TCS monitor overtemperature,

More information

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories 2CDC 251 014 F0t09 Features Monitoring of three-phase mains for grid feeding Type-tested in accordance with DIN V VDE V 0126-1-1: February 2006 Neutral conductor connection configurable Can also be used

More information

THE ADVANTAGES ARE YOURS

THE ADVANTAGES ARE YOURS THE ADVANTAGES ARE YOURS The new switches/discrepancy switches "R0-DR0" have special characteristics that make them very different from the normal switches on the market. Listed below are some of the many

More information

Installation Contactors. Technical Catalogue. Type ESB. abb. ABB STOTZ-KONTAKT GmbH 1 2CDC 103002 C0201

Installation Contactors. Technical Catalogue. Type ESB. abb. ABB STOTZ-KONTAKT GmbH 1 2CDC 103002 C0201 Technical Catalogue Installation Contactors Type ESB abb ABB STOTZ-KONTAKT GmbH 1 CDC 10300 C001 ABB STOTZ-KONTAKT GmbH CDC 10300 C001 Low Voltage Products and Systems We ensure safety and comfort for

More information

Cross-beam scanning system to detect slim objects. 100 mm 3.937 in

Cross-beam scanning system to detect slim objects. 100 mm 3.937 in 891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC

More information

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors. 40-300 mm background suppression

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors. 40-300 mm background suppression Advanced line of miniature Asian style of photoelectric sensors 4-3 background suppression.7 m proximity, 15 with narrow beam 4 m polarized retroreflective 3 m LASER through beam Standard 3-wire output

More information

Manual Motor Starter MS 116 up to 16 A Technical Data

Manual Motor Starter MS 116 up to 16 A Technical Data Manual Motor Starter MS 116 up to 16 A Technical Data Type MS 116 Standards: Major International IEC 60 947-4-1 / IEC 60 947-2 and European Standards EN 60 947-4-1 / EN 60 947-2 Approvals, Certificates

More information

MOTOR PROTECTIVE DEVICES

MOTOR PROTECTIVE DEVICES W MOTOR PROTECTIVE DEVICE, SERIES MP 206 BE400206 BE400306 Inherently stable without back-up fuseup to 4 A at 400 V AC, > 4 A main back-up fuse 100 A gl Thermal and magnetic release Terminal and accessory

More information

Voltage Rated operating voltage [kv] 12 24 Rated power frequency withstand voltage [kv] 28 50 Rated lightning impulse withstand voltage [kv] 75 125

Voltage Rated operating voltage [kv] 12 24 Rated power frequency withstand voltage [kv] 28 50 Rated lightning impulse withstand voltage [kv] 75 125 Standards and Regulations IEC 62271-200 ; VDE 0671-200 ; BS EN 62271-200 Technical Data MC3-12 MC3-24 Voltage Rated operating voltage [kv] 12 24 Rated power frequency withstand voltage [kv] 28 50 Rated

More information

3K Load-Break Switches The Program for Safety and Performance. sentric

3K Load-Break Switches The Program for Safety and Performance. sentric 3K Load-Break Switches The Program for Safety and Performance sentric Whether for reliable switching and isolation under load, or for protection against overload or short-circuits our 3K range of load-break

More information

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application. 1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay

More information

2011 DC Electropumps Bull. Rotation Ø 15 6,45 3,5 5,7

2011 DC Electropumps Bull. Rotation Ø 15 6,45 3,5 5,7 Ø 5 ±. DC Electropumps Bull,5 Rotation,5 5,7 Email: sales@hydronit.com Fax B... Electro pumps Bull series MODEL CODE EPB,5 DC /S5 K, V** Electro Pump Bull series Gear pump displacement (cc/rev (see tables

More information

ATS - Automatic Changeover

ATS - Automatic Changeover ATS - Automatic Changeover Manufacturers of Electrical Switchgear Choosing an Automatic Transfer System Switchgear Systems offer a variety of solutions for multiple supply switching needs. As well as our

More information

Switchboard system. NorLine 800

Switchboard system. NorLine 800 Switchboard system NorLine 800 NorLine 800 SWITCHBOARD SYSTEM 2 NorLine 800 Switchboard system Table of contents Subject Page Table of contents 2 Overview 2-3 NorLine 800 technical specifications 4 Structural

More information