Spare parts Catalogue

Size: px
Start display at page:

Download "Spare parts Catalogue"

Transcription

1 Technical catalogue Spare parts Catalogue Low voltage circuit-breakers Product support ABB SACE SDC0000D00

2 Not every original spare parts are really original spare parts. Availability of spare parts for the air or moulded-case type of apparatus is an essential condition for correct maintenance of every installation. This becomes even more important when the installation was built some years ago and has pieces of apparatus in it which are now of phased-out production. Here again, ABB SACE can offer you maximum longterm guarantees. In fact, the company s Technical Assistance manages an efficient Spare Parts Service with components in stock which cover practically all the apparatus produced from the 0s up to today. All the spare parts are original ABB SACE pieces and are, moreover, covered by a warranty. On the basis of the apparatus installed, ABB SACE s Technical Assistance also collaborates with customers who want to create local rapid intervention warehouses tailored to the requirements of the individual plant, with spare parts and technical consumer materials. To ensure maximum levels of assistance and to facilitate selection and ordering of the spare parts, ABB SACE uses a capillary network of agencies distributed throughout the territory, able to deal with any request you may have rapidly, with competent personnel who you can contact directly for any needs regarding our products. The ABB SACE catalogue also helps to simplify spare part selection and ordering: in fact, its card-type structure, with detailed monographs on the apparatus, means the code of the desired product can be found immediately. ABB SACE's TECHNICAL ASSISTANCE. We know how.

3 ABB SACE's Technical Assistance. An all-round service. ABB SACE's Technical Assistance offers you a service package to keep your plants fully efficient. Repairs Functional recovery of each electrical and mechanical part of the circuit-breaker with completely free estimates. Moreover, following a total overhaul of the circuitbreaker, the warranty is reinstated for months from re-delivery. Maintenance operations Apart from maintenance on fault, which includes any type of emergency intervention, there is a complete preventive maintenance offer, ensuring those who manage the plant considerable advantages in terms of reliability, safety and reduction of costs. Retrofitting Replacement of old pieces of apparatus with others of more up-to-date concept thanks to the special conversion kits which allow rapid installation without structural modifi cations to the original compartment. Furthermore, complete turnkey formula supplies are available. Consultancy & Global Assistance Technicians competent regarding the products and Standards are available to verify the situation of the installations and apparatus and to propose tailored maintenance plans, divided up into several levels of completeness. Fault Prevention and Thermography Methods for forecasting and preventing faults based on the use of advanced apparatus, which guarantees extremely reliable results. Among these is the thermographic check aimed at showing up any overheating of the conductive and insulating parts of the installation. Training Training programmes which give the personnel in charge of managing/maintaining the installation the know-how needed to achieve operating independence. Apart from technologies, a Technical Assistance truly at the service of customers: a team of capable and skilled people, always ready to listen to, understand and solve matters. Beside the customer at all times.

4 Instructions The present catalogue lists all the parts available for ABB SACE LV circuit-breakers. Each part or set of parts is identified by its UXAB or SDA0 code which is the only information that must always be utilized for placing orders. For the correct identification of those spare parts which are not included in the present catalogue, the serial number of the relative breaker must be ever reported. Spare parts not codified can be only supplied following information by ABB SACE. Spare parts called kit include a set of parts suitable for completing a whole circuit-breaker. Caption: A = spare parts which can be assembled by ABB SACE technicians only either for technical reasons or because of the need of special equipment. X = last product available This catalogue may be subject of changes or updates. For any further information please keep in contact with your local sales organization. SDC0000D00 ABB SACE

5 Summary Low voltage moulded-case circuit-breakers ISOL - FUSOL series... / MODUL series... / LIMITOR series... / ISOMAX series... / MCCBs TMAX series... / SD-VIEW series... /9 Low voltage air circuit-breakers OTOMAX series... / NOVOMAX G0 series... / NOVOMAX G-G - LG series... / ACBs MEGAMAX series... / EMAX series... / NEW EMAX series... /9 ABB SACE SDC0000D00

6 Low voltage moulded-case circuit-breakers ISOL - FUSOL series Isol - Fusol ABB SACE / SDC0000D00

7 Low voltage moulded-case circuit-breakers Withdrawable FZ 0 FUSOL Isol - Fusol 9 0 Withdrawable Z 800/MM ISOL 8 9 / ABB SACE SDC0000D00

8 ISOL Z 0 - Z 0/MM Isol - Fusol Caption ) No. main fixed contacts + moving poles set ) No. arc chambers c/w locking plate ) Handle lever for normal/solenoid operating mechanism ) Front shield ) Rear cover ) Main insulating base + fixed part protection ) No. rear terminals for fixed part + isolating contacts 8) Plug and socket kit for auxiliary applications 9) Gasket for panel s door 0) No. fuses set ) TM relay in AC use (Im=/ Ith, not delayed) ) TM relay in DC use (Im=/ Ith, not delayed) ) TM relay in AC use (Im=/0 Ith, not delayed) ) TM relay in AC use (Im=/ Ith, 0.0 sec delayed) ) TM relay in DC use (Im=/ Ith, 0.0 sec delayed) ) TM relay in AC use (Im=/0 Ith, 0.0 sec delayed) ABB SACE / SDC0000D00

9 Low voltage moulded-case circuit-breakers Spare part description Type UXAB code Q.ty Note No. main fixed contacts + moving poles set Z0 - FZ A Z A No. arc chambers c/w locking plate Z FZ Handle lever for normal operating mechanism Z FZ Handle lever for solenoid operating mechanism Z FZ Front shield Z FZ Isol - Fusol 8 Rear cover Z FZ Main insulating base + fixed part protection Z0 - FZ () Z No. rear terminals for fixed part + isolating contacts Z0 - FZ0_tulip contacts Z800_jaw contacts Plug and socket kit for auxiliary applications Z FZ Gasket for panel s door Z FZ No. fuses set FZ0 _ In=00A 9099 FZ0 _ In=00A 9099 TM relay in AC use (Im=/ Ith, not delayed) Z0 - FZ0 R Z0 - FZ0 R Z0 - FZ0 R Z0 - FZ0 R Z0 - FZ0 R Z0 R Z0 R Z800 R Z800 R Z800 R Z800 R Z800 R Z800 R Z800 R Z800 R TM relay in DC use (Im=/ Ith, not delayed) Z0 - FZ0 R Z0 - FZ0 R Z0 - FZ0 R Z0 - FZ0 R Z0 - FZ0 R Z0 R Z0 R Z800 R Z800 R Z800 R Z800 R Z800 R Z800 R Z800 R Z800 R () The protection for the fixed part should not be used for ISOL Z 0 X = Last product available A = Assembly reserved to ABB SACE skilled technician / ABB SACE SDC0000D00

10 Spare part description Type UXAB code Q.ty Note TM relay in AC use (Im=/0 Ith, not delayed) Z0 - FZ0 R Z0 - FZ0 R Z0 - FZ0 R Z0 - FZ0 R Z0 - FZ0 R Z0 R Z0 R Z800 R Z800 R Z800 R Z800 R Z800 R Z800 R Z800 R Z800 R TM relay in AC use (Im=/ Ith, 0.0 sec delayed) Z0 - FZ0 R Z0 - FZ0 R Z0 - FZ0 R Z0 - FZ0 R Z0 - FZ0 R Z0 R Z0 R Z800 R Z800 R Z800 R Z800 R Z800 R Z800 R Z800 R Z800 R TM relay in DC use (Im=/ Ith, 0.0 sec delayed) Z0 - FZ0 R Z0 - FZ0 R Z0 - FZ0 R Z0 - FZ0 R Z0 - FZ0 R Z0 R Z0 R Z800 R Z800 R Z800 R Z800 R Z800 R Z800 R Z800 R Z800 R TM relay in AC use (Im=/0 Ith, 0.0 sec delayed) Z0 - FZ0 R Z0 - FZ0 R Z0 - FZ0 R Z0 - FZ0 R Z0 - FZ0 R Z0 R Z0 R Z800 R Z800 R Z800 R Z800 R Z800 R Z800 R Z800 R Z800 R X = Last product available A = Assembly reserved to ABB SACE skilled technician Isol - Fusol ABB SACE / SDC0000D00

11

12 Low voltage moulded-case circuit-breakers MODUL series Modul ABB SACE / SDC0000D00

13 Low voltage moulded-case circuit-breakers MODUL SRN-SRH 00- Modul /8 ABB SACE SDC0000D00

14 Modul Caption ) 9 poles plug for auxiliary applications ) Upgrade kit for fixed breaker in PMP ) RCSD0 residual current relay ) Rotary operating mechanism on panel s door fitted with lock and padlock ) No. No/Nc change-over contact and tripped relay contact ) Sealable terminal covers ) Opening solenoid for RCSD0 residual current relay Spare part description Type Code Q.ty Note 9 poles plug for auxiliary applications Complete range Upgrade kit for fixed breaker in PMP p 9008 X p 9008 X RCSD0 residual current relay Complete range, sideplaced 9800 X Complete range, underplaced 9800 X Rotary operating mechanism on panel s door fitted Complete range 9000 with lock and padlock No. No/Nc change-over contact and tripped relay contact Complete range 9000 Sealable terminal covers p 900 X p 900 X Opening solenoid for RCSD0 residual current relay Complete range X X = Last product available A = Assembly reserved to ABB SACE skilled technician ABB SACE /9 SDC0000D00

15 Low voltage moulded-case circuit-breakers MODUL SN SH Modul /0 ABB SACE SDC0000D00

16 9 0 Modul ABB SACE / SDC0000D00

17 Low voltage moulded-case circuit-breakers Caption ) Arc chambers set ) Tulip contacts set ) Rotary handles set ) Main cover + terminals protection ) Kit of terminals for cables version (fixed) Modul ) Upgrade kit from fixed breaker to PMP ) Upgrade kit from fixed breaker to WMP 8) Rear terminals kit for poles fixed breaker 9) Opening coil 0) Undervoltage release ) No. No/Nc change-over contacts ) 8 poles plug for auxiliary applications ) Rotary operating mechanism on breaker ) Rotary operating mechanism on panel s door ) Flange for WMP breaker fitted with standard operating lever ) Flange for motor operator ) Extender flange for breaker s main cover 8) Sealable terminals cover for / poles breaker 9) Sealable terminals cover for poles breaker 0) RCS residual current release ) Solenoid for RCS residual current relay ) Solenoid for RCS residual current relay / ABB SACE SDC0000D00

18 Spare part description Type UXAB code Q.ty Note Arc chambers set Complete range Tulip contacts set SN/SH SH Rotary handles set Complete range X Main cover + terminals protection Complete range X 8 Kit of terminals for cables version (fixed) Complete range X Upgrade kit from fixed breaker to PMP SN00- p X SN00- p X SH00- p X SH00- p X Upgrade kit from fixed breaker to WMP SH00- p X SH00- p X Rear terminals kit for poles fixed breaker SN/SH X Modul Opening coil SH-0 V AC 9090 SH - SN/SH0 8-0V AC 9090 SH - SN/SH0 00-0V AC 9099 SH - SN/SH0 00-0V AC 9098 SN00-8-0V DC 8990 SN V AC 8999 SN V AC 8998 Undervoltage release SH--0 V DC 9090 SH--0 8V DC 9090 SH - SN/SH0 0V 0Hz V 0Hz SH - SN/SH0 80V 0Hz 0V 0Hz 9089 X SN00-0V 0Hz V 0Hz X No. No/Nc change-over contacts SH00- - SN/SH poles plug for auxiliary applications SN-SH Rotary operating mechanism on breaker SH00- - SN/SH X Rotary operating mechanism on panel door SH00- - SN/SH SN Flange for WMP breaker fitted with standard SH operating lever Flange for motor operator SN/SH Extender flange for breaker s main cover SH00- - SN/SH0 900 X Sealable terminals cover for / poles breaker SN X SH00- - SN/SH X Sealable terminals cover for poles breaker SN X SH00- - SN/SH X RCS residual current release SN X Solenoid for RCS residual current relay SN X Solenoid for RCS residual current relay SH X = Last product available A = Assembly reserved to ABB SACE skilled technician ABB SACE / SDC0000D00

19 Low voltage moulded-case circuit-breakers MODUL SAN-SAH 0 Modul Caption ) Arc chambers set ) Tulip contacts set ) Rotary handles set ) Kit of terminals for cables version (fixed) ) Opening coil ) Undervoltage release 8) No. No/Nc change-over contact and tripped relay contact / ABB SACE SDC0000D00

20 Spare part description Type UXAB code Q.ty Note Arc chambers set Complete range 9880 Tulip contacts set Complete range Rotary handles set Complete range X Kit of terminals for cables version (fixed) Complete range X Opening coil 00/0V AC-DC /V AC-DC 998 Undervoltage release /0V 0Hz 9890 Modul Electronic delayer for undervoltage release Complete range No. No/Nc change-over contact and tripped relay contact Complete range X X = Last product available A = Assembly reserved to ABB SACE skilled technician ABB SACE / SDC0000D00

21 Low voltage moulded-case circuit-breakers MODUL SN-SH 00 Modul / ABB SACE SDC0000D00

22 Modul ABB SACE / SDC0000D00

23 Low voltage moulded-case circuit-breakers MODUL SN-SH 00 Modul /8 ABB SACE SDC0000D00

24 Caption ) Arc chambers set ) Tulip contacts set ) Operating levers set ) Rotary handles set ) Main cover ) Terminals protections set ) Rails for fixed part 8) Solenoid for S electronic release Modul 9) Draw out lever 0) 8 poles plug for auxiliary applications ) Upgrade kit from fixed breaker to PMP ) Upgrade kit from fixed breaker to WMP ) TM relay in AC use ) Magnetic relay in AC use ) No. No/Nc change over contacts ) No. No/Nc change over contacts + tripped relay contact ) Rotary operating mechanism on breaker 8) Rotary operating mechanism on panel s door 9) Motor operator 0) Opening coil ) Undervoltage release ) Extender flange for breaker s main cover ) Sealable terminals cover ) Front shield for poles breaker fitted with S electronic release ABB SACE /9 SDC0000D00

25 Low voltage moulded-case circuit-breakers Spare part description Type UXAB code Q.ty Note Arc chambers set Complete range Tulip contacts set Complete range Operating levers set Complete range X Rotary handles set Complete range Modul Main cover For p breaker fitted with TM release X For p breaker fitted with TM release X Terminals protections set Complete range X Rails for fixed part Complete range Solenoid for S electronic release Complete range X Draw out lever p 9800 p poles plug for auxiliary applications Complete range 9000 Upgrade kit from fixed breaker to PMP p X p X Upgrade kit from fixed breaker to WMP p X p X TM relay in AC use R0 for p breaker 89 R0 for p breaker 89 R00 for p breaker 89 R0 for SAH breaker, p 98 X R00 for SAH breaker, p 98 X R00 for SAH breaker, p 98 X R0 for SAH breaker, p 98 X R00 for SAH breaker, p 98 X R0 for SAH breaker, p 98 X R00 for SAH breaker, p 98 X Magnetic relay in AC use For MODUL MCS00, Im=000A 98 X For MODUL MCP00, Im=000/000A 98 X No. No/Nc change over contacts For breaker fitted with TM release No. No/Nc change over contacts + tripped relay contact For breaker fitted with TM release X Rotary operating mechanism on breaker Complete range Rotary operating mechanism on panel s door Complete range Motor operator 0V 0Hz V 0Hz 8998 Opening coil SAH00, V DC 9890 SN-SH00, V DC 9890 SN-SH00, 8V DC 9890 SN-SH00, 00/V DC - 0/80V AC SN-SH00, 0/0V DC - 0/0V AC 9898 SN-SH00, V AC 989 SN-SH00, /00V DC - 00/V AC 9899 SN-SH00, 00/V AC 9898 SN-SH00, 0V DC 989 SAH00, 0V 0Hz 989 X = Last product available A = Assembly reserved to ABB SACE skilled technician /0 ABB SACE SDC0000D00

26 Spare part description Type UXAB code Q.ty Note Undervoltage release SAH00, 0V 0Hz 989 SN-SH00, V DC 9890 SN-SH00, 8V DC 9890 SN-SH00, 0V DC SN-SH00, 0-V 0Hz -V 0Hz 9899 SN-SH00, 0V 0Hz - V 0Hz 9898 SN-SH00, 80V 0Hz - 0V 0Hz 989 SN-SH00, 0V 0Hz 9898 Extender flange for breaker s main cover Complete range Sealable terminals cover SN-SH00, -p breaker 8900 X SN-SH00, p breaker 8900 X Front shield for poles breaker fitted with S SAH X electronic release Modul X = Last product available A = Assembly reserved to ABB SACE skilled technician ABB SACE / SDC0000D00

27 Low voltage moulded-case circuit-breakers MODUL SN-SH 0/800 8 Modul 8 0 / ABB SACE SDC0000D00

28 Modul ABB SACE / SDC0000D00

29 Low voltage moulded-case circuit-breakers MODUL SN-SH 0/800 Modul / ABB SACE SDC0000D00

30 Caption ) Arc chambers set ) Tulip contacts set ) Main fixed contacts set ) Operating levers set ) Rotary handles set ) Main front cover ) Moving contacts assembly 8) Single terminal + single jaw contact (on WFP) kit Modul 9) Opening solenoid for S electronic release 0) Draw out lever ) Upgrade kit from fixed breaker to PMP ) Upgrade kit from fixed breaker to WMP ) TM release in AC use ) poles plug for auxiliary applications ) No. No/Nc change over contact ) No. No/ Nc auxiliary contacts set ) No. No/Nc change-over contacts + tripped relay contact 8) No. No/Nc aux contacts set + tripped relay contact 9) No. No/Nc change-over contacts + tripped relay for breaker fitted with S electronic release 0) Rotary operating mechanism on breaker ) Rotary operating mechanism on panel s door ) Motor operator ) Opening coil ) Undervoltage release ) Single CT + support for S electronic relay ) Cover for breaker fitted with S electronic release ) Extender flange for breaker s main cover 8) Sealable terminals cover 9) Padlock for standard operating lever 0) Keylock for rotary operating mechanism on breaker ABB SACE / SDC0000D00

31 Low voltage moulded-case circuit-breakers Spare part description Type UXAB code Q.ty Note Arc chambers set Complete range 9990 Tulip contacts set SN-SH Main fixed contacts set Complete range Operating levers set Complete range Modul 8 9 Rotary handles set Complete range Main front cover For p breaker fitted with TM release X For p breaker fitted with TM release X For p breaker fitted with S electronic release X For p breaker fitted with S electronic release X Moving contacts assembly p A p X A Single terminal + single jaw contact (on WFP) kit SN/SH800, for HR terminals or X SN/SH800, for RV terminals or X SN/SH800, for F terminals or X Opening solenoid for S electronic release Complete range X Draw out lever SN-SH0-800, /p 9800 SN-SH0-800, p 9800 Upgrade kit from fixed breaker to PMP SN/SH0, p 900 SN/SH0, p 900 Upgrade kit from fixed breaker to WMP SN/SH0, p 900 SN/SH0, p 900 SN/SH800, p 8900 X SN/SH800, p 8900 X TM release in AC use SN-SH800, p R SN-SH800, p R SN-SH0, p R SN-SH0, p R SN-SH800, p R SN-SH800, p R SN-SH0, p R SAH00, R00 9 X SAH00, R00 99 X SAH800, R00 9 X SAH800, R800 9 X poles plug for auxiliary applications On right hand side On left hand side No. No/Nc change over contact SN/SH No. No/ Nc auxiliary contacts set SN/SH No. No/Nc change-over contacts + tripped relay contact SN/SH No. No/Nc aux contacts set + tripped relay contact SN/SH No. No/Nc change-over contacts + tripped relay for breaker fitted with S electronic release SAH X Rotary operating mechanism on breaker SN/SH X = Last product available A = Assembly reserved to ABB SACE skilled technician / ABB SACE SDC0000D00

32 Spare part description Type UXAB code Q.ty Note Rotary operating mechanism on panel s door SN/SH Motor operator 0V V V Opening coil V DC and 8V AC V DC /V DC - 0/80V AC /0V DC - 0/0V AC V AC 9089 /00V DC - 00/V AC V DC - 00/V AC V DC - 80/00V AC 9089 SAH00-800, V DC for breaker fitted with S electronic release SAH00-800, 0V AC for breaker fitted with S electronic release X 9089 X Undervoltage release V DC V DC V DC V DC V 0Hz - 0V 0Hz V 0Hz - V 0Hz V 0Hz - 0V 0Hz 9089 Single CT + support for S electronic relay SAH00, for single phase X SAH00, for neutral pole 9000 X Cover for breaker fitted with S electronic release SAH X Extender flange for breaker s main cover SN/SH Sealable terminals cover SN/SH0, /p 900 X SN/SH0, p 900 X SN/SH800, /p 8900 X SN/SH800, p 8900 X Padlock for standard operating lever Complete range 900 Keylock for rotary operating mechanism on breaker Complete range Modul X = Last product available A = Assembly reserved to ABB SACE skilled technician ABB SACE / SDC0000D00

33 Low voltage moulded-case circuit-breakers MODUL SN-SH 0/00 Modul /8 ABB SACE SDC0000D00

34 Modul ABB SACE /9 SDC0000D00

35 Low voltage moulded-case circuit-breakers MODUL SN-SH 0/00 Modul /0 ABB SACE SDC0000D00

36 Caption ) Arc chambers set ) Main fixed contacts set ) Rotary handles set ) Main cover ) Insulating base for fixed part ) Draw out lever ) Rear terminals kit with shunts for fixed breaker (In=<000A) 8) Front terminals set for poles breaker (In=<000A) Modul 9) Rear terminals kit with through bar for fixed breaker (In=>0A) 0) Front terminals set for poles breaker (In=>0A) ) Upgrade kit from fixed breaker to WMP (In=<000A) ) Upgrade kit from fixed breaker to WMP (In=>0A) ) TM release in AC use ) poles plug and socket kit for auxiliary applications (on right hand side) ) No. No/ Nc auxiliary contacts set ) No. No/Nc aux contacts set + tripped relay contact ) Motor operator 8) Opening coil 9) Undervoltage release 0) Opening solenoid for S electronic release complete with No+Nc + tripped relay contacts ) Flange for WMP breaker fitted with standard operating lever ) Flange for F or PMP breaker fitted with rotary operating lever ) Flange for WMP breaker fitted with rotary operating lever ) Flange for motor operator ) S base relay complete with no. CTs r00a Main frontal cover ) Padlock for standard operating lever ABB SACE / SDC0000D00

37 Low voltage moulded-case circuit-breakers Spare part description Type UXAB code Q.ty Note Arc chambers set Complete range 9990 Main fixed contacts set Complete range 9990 A Rotary handles set Complete range Main cover For p breaker fitted with TM release 9990 X Modul For p breaker fitted with S electronic release For p breaker fitted with S electronic release 9990 X 9990 X Insulating base for fixed part p 9990 p 9990 Draw out lever SN-SH0-00, /p SN-SH0-00, p Rear terminals kit with shunts for fixed breaker (In=<000A) SN-SH0, p 900 SN-SH0, p 900 SN-SH00, p SN-SH00, p Front terminals set for poles breaker (In=<000A) SAH Rear terminals kit with through bar for fixed breaker (In=>0A) SN-SH0, p 900 SN-SH0, p 900 Front terminals set for poles breaker (In=>0A) SAH Upgrade kit from fixed breaker to WMP (In=<000A) SN-SH0, p 9009 SN-SH0, p 9009 X SN-SH00, p SN-SH00, p X Upgrade kit from fixed breaker to WMP (In=>0A) SN-SH0, p 9008 SN-SH0, p 9008 X SN-SH00, p SN-SH00, p X TM release in AC use SN-SH0, R800 p c/w shunts 9 SN-SH0, R000 p c/w shunts 9 SN-SH0, R0 p c/w through bar 9 SN-SH0, R800 p c/w shunts 9 X SN-SH0, R000 p c/w shunts 9 X SN-SH0, R0 p c/w through bar 9 X SAH00, R SAH00, R poles plug and socket kit for auxiliary applications SN-SH0 900 (on right hand side) No. No/ Nc auxiliary contacts set Complete range, right hand side for breaker fitted with TM release 9000 No. No/Nc aux contacts set + tripped relay contact Complete range 9000 Motor operator SN-SH0/00, 0V 999 SN-SH0/00, 0-0V 998 X = Last product available A = Assembly reserved to ABB SACE skilled technician / ABB SACE SDC0000D00

38 Spare part description Type UXAB code Q.ty Note Opening coil SN-SH0-00, V DC or 8V AC 990 SN-SH0-00, 8V-0V DC 990 SN-SH0-00, 00/V DC - 0/80V AC 9909 SN-SH0-00, /00V DC - 00/V AC 999 SN-SH0-00, 0V DC - 00/V AC 998 SN-SH00, -00V DC_00-V AC for 999 breaker fitted with S electronic release SN-SH00, 0V DC_0-0V AC for breaker fitted with S electronic release 998 Undervoltage release SN-SH0-00, V DC 990 SN-SH0-00, 8V DC 990 SN-SH0-00, 0V DC 9909 SN-SH0-00, 0V DC 998 SN-SH0-00, 0V 0Hz - V 0Hz 998 SN-SH0-00, 80V 0Hz - 0V 0Hz 99 SAH00, 0V 0Hz -0V 0Hz 99 SAH00, V DC for breaker fitted with S electronic release 99 Opening solenoid for S electronic release complete with No+Nc + tripped relay contacts Flange for WMP breaker fitted with standard operating lever Flange for F or PMP breaker fitted with rotary operating lever Flange for WMP breaker fitted with rotary operating lever SAH00, 0V DC for breaker fitted with S electronic release SN-SH00, 0V 0Hz - V 0Hz for breaker fitted with S release Complete range 9000 SN-SH SN-SH SN-SH Flange for motor operator SN-SH S base relay complete with no. CTs r00a SAH X Main frontal cover SAH Padlock for standard operating lever Complete range 900 Modul X = Last product available A = Assembly reserved to ABB SACE skilled technician ABB SACE / SDC0000D00

39 Low voltage moulded-case circuit-breakers MODUL SN-SH 000/00 Modul Caption ) Arc chambers set ) Main fixed contact ) Moving contacts ) Operating lever ) Main cover ) Opening solenoid ) Gasket for compartment s door 8) Opening coil 9) Undervoltage release 0) No. Na/Nc auxiliary contacts + No. contacts for tripped relay NOTE For the components for Modul SH-SH-SM/M not listed in the catalogue please refer to the corresponding accessories available for SACE Isomax S8. For the closing and opening releases of the circuit breakers S8 the numbering of the connections changes (invert C with C and C with C) / ABB SACE SDC0000D00

40 Spare part description Type UXAB code Q.ty Note Arc chambers set Complete range Main fixed contact Complete range, for phases A Complete range, for neutral pole A Moving contacts SAN-SAH-SM , R+T phases A SAN-SAH-SM , S phase A SAN-SAH-SM , neutral pole A SN-SH-SM/M , R+S+T phases A SN-SH-SM/M , neutral pole A Operating lever SAN-SAH-SM complete with 9990 extension lever SN-SH-SM/M , standard 9990 Main cover SAN-SAH-SM , for phases X SAN-SAH-SM , for neutral pole X only SN-SH-SM/M , for phases 9990 X SN-SH-SM/M , for neutral pole 9990 X only Opening solenoid SN-SH-SAN-SAH , for S electronic release Gasket for compartment s door SN-SH-SM/M X SAN-SAH-SM X Opening coil V DC - 8V AC /V DC - 0/80 V AC 9909 /00V DC - 00/V AC 999 0V DC 00-V AC 998 0V DC - 80/00V AC 99 V AC 99 V DC 990 0V DC 990 8V DC 990 0/0 V DC - 0/0 V AC 998 Undervoltage release /0V DC 990 0V / 0Hz /00V 0Hz 0V 0Hz 99 08/0V / 0Hz V 0Hz 998 8/0V DC 990 0/ V DC 99 0/0 V DC 99 0V DC 99 V 0 Hz 99 0V 0 Hz 99 8V 0 Hz 99 0V 0 Hz 99 00V 0 Hz - 0/ V 0Hz 999 0V 0Hz 990 0/V 0Hz - 0/V 0Hz 999 /0V 0Hz 99 0V 0Hz 998 0/0 V 0HZ - V 0Hz 99 /0V 0Hz - 80V 0Hz 99 00V 0Hz 99 No. Na/Nc auxiliary contacts + No. contacts for SAN-SAH-SM tripped relay Modul X = Last product available A = Assembly reserved to ABB SACE skilled technician ABB SACE / SDC0000D00

41

42 Low voltage moulded-case circuit-breakers LIMITOR series Limitor ABB SACE / SDC0000D00

43 Low voltage moulded-case circuit-breakers LIMITOR LN 0/00 - LN 0 MS: Basic components Limitor Caption ) No. arc chambers ) Main fixed contacts set ) Tulip contacts set ) Moving double contacts set ) Main frontal cover + terminals protection ) Operating levers + matching plate for motor operator ) Rotary handles set Spare part description Type UXAB code Q.ty Note No. arc chambers Main fixed contacts set A Tulip contacts set Moving double contacts set A Main frontal cover + terminals protection 9990 A () Operating levers + matching plate for motor operator 9990 Rotary handles set LN0/00/0 MS 9990 () The covers are supplied without plates X = Last product available A = Assembly reserved to ABB SACE skilled technician /8 ABB SACE SDC0000D00

44 LIMITOR LN 0 - LN 0 MS: Basic components Limitor Caption ) No. arc chambers ) Main fixed contacts set ) Moving double contacts set ) Tulip contacts set ) Main frontal cover + terminals protection ) Operating levers + matching plate for motor operator ) Rotary handles set 8) Draw out lever Spare part description Type UXAB code Q.ty Note 8 No. arc chambers Main fixed contacts set LN A LN0 MS 9990 A Moving double contacts set LN A LN0 M 9990 A Tulip contacts set Main frontal cover + terminals protection 9990 A () Operating levers + matching plate for motor operator 9990 Rotary handles set LN0/00/0 MS 9990 Draw out lever p 9800 p 9800 () The covers are supplied without plates X = Last product available A = Assembly reserved to ABB SACE skilled technician ABB SACE /9 SDC0000D00

45 Low voltage moulded-case circuit-breakers LIMITOR LN 00/0 - LN 00 MS: Basic components Limitor Caption ) Arc chambers + filters set ) Main fixed contacts set ) Moving double contacts set ) Tulip contacts set ) Main frontal cover + terminals protection ) Operating levers + matching plate for motor operator ) Rotary handles set 8) Draw out lever Spare part description Type UXAB code Q.ty Note 8 Arc chambers + filters set p p Main fixed contacts set LN00/ A LN00 MS 9990 A Moving double contacts set LN00/0, or p A LN00/0, p A LN00 MS 9990 A Tulip contacts set LN00 - LN00 MS Main frontal cover + terminals protection p () p () Operating levers + matching plate for motor operator Rotary handles set LN00/0/800/000 MS Draw out lever p 9800 p 9800 () The covers are supplied without plates X = Last product available A = Assembly reserved to ABB SACE skilled technician /0 ABB SACE SDC0000D00

46 LIMITOR LN 800/000 - LN 800 MS: Basic components Caption ) Arc chambers + filters set ) Main fixed contacts set ) Moving double contacts set ) Single terminal and jaw contact (on FP) assembly ) No. terminals for moving part ) Front shield ) Operating levers + matching plate for motor operator Limitor 8) Rotary handles set 9) Draw out lever 8 0) Flange for compartment s door Spare part description Type UXAB code Q.ty Note Arc chambers + filters set Main fixed contacts set LN800/ A LN800 MS 9990 A Moving double contacts set LN800/ A LN800 MS 9990 A Single terminal and jaw contact (on FP) assembly LN800, F terminal 9900 LN800, HR terminal 9900 LN800, RV terminal 9900 No. terminals for moving part 9990 Front shield () Operating levers + matching plate for motor operator Rotary handles set LN00/0/800/000 MS Draw out lever LN Flange for compartment s door LN800 WMP, standard operating mechanism 900 LN800, PMP or F c/w rotary operating lever 900 LN800, WMP c/w rotary operating lever 900 LN800 c/w motor operator 900 () The covers are supplied without plates X = Last product available A = Assembly reserved to ABB SACE skilled technician ABB SACE / SDC0000D00

47

48 Low voltage moulded-case circuit-breakers ISOMAX series Isomax ABB SACE / SDC0000D00

49 Low voltage moulded-case circuit-breakers ISOMAX series Isomax 8 / ABB SACE SDC0000D00

50 Caption ISOMAX S-S-S ) Solenoid for residual current relais ) Front cover complete with operating lever ) No. arc chambers set ) No. 8 tulip contacts set ) Operating lever ISOMAX S-S Isomax ) Front cover complete with operating lever ) No. arc chambers set ) No. 8 tulip contacts set ) Operating lever ISOMAX S-S ) Front cover complete with operating lever ) No. arc chambers set ) No. 8 jaw contacts fitted with terminals for fixed part ) Operating lever 8) Operating lever ABB SACE / SDC0000D00

51 Low voltage moulded-case circuit-breakers ISOMAX S-S-S Spare part description Type SDA code Q.ty Note Isomax Solenoid for residual current relais S-S for RC0-- 0R S for RC 0R Front cover complete with operating lever S N-H, p 09R S N-H, p 09R S L, p 09R S L, p 09R No. arc chambers set S 00R No. 8 tulip contacts set S 0R Operating lever S-S-S 0R ISOMAX S-S Spare part description Type SDA code Q.ty Note Front cover complete with operating lever S N-H, p 09R S N-H, p 09R S L, p 098R S L, p 099R S N-H, p 000R S N-H, p 00R S L, p 00R S L, p 00R No. arc chambers set S 0R S 0R No. 8 tulip contacts set S 0R S 0R Operating lever S-S-S 0R ISOMAX S-S Spare part description Type SDA code Q.ty Note 8 Front cover complete with operating lever S, p 00R S, p 00R S, p 00R S, p 00R No. arc chambers set S 089R S 09R No. 8 jaw contacts fitted with terminals for fixed part S, F terminals 008R S, HR terminals 009R S, RV terminals 00R S, F terminals 0R S, HR terminals 0R S, RV terminals 0R Operating lever S 08R Operating lever S 090R X = Last product available A = Assembly reserved to ABB SACE skilled technician / ABB SACE SDC0000D00

52 Low voltage moulded-case circuit-breakers TMAX series Tmax ABB SACE / SDC0000D00

53 Low voltage moulded-case circuit-breakers TMAX series Caption ) Opening solenoid for RC- residual current relay + Aux contact K ) Opening solenoid for RC- residual current relay + Aux contact K ) Opening solenoid for RC- residual current relay + Aux contact K Tmax ) Opening solenoid for PR electronic release ) Opening solenoid for RC--- + Aux contact K ) Flange for compartment s door Spare part description Type SDA code Q.ty Note Opening solenoid for RC- residual current relay + Aux contact K Opening solenoid for RC- residual current relay + Aux contact K Opening solenoid for RC- residual current relay + Aux contact K Tmax T 00R Tmax T 00R Tmax T 008R Opening solenoid for PR electronic release Tmax T 00R Opening solenoid for RC--- + Aux contact K Tmax T-T 009R Flange for compartment s door Tmax T c/w MOS or RHD 00R Tmax T WMP 00R Tmax T F 00R Tmax T-T p with RC F or PMP 009R Tmax T-T p, WMP 009R Tmax T-T p, F or PMP 009R Tmax T-T-T 009R Tmax T-T-T, c/w MOS or RHD 00R Tmax T-T-T c/w RC_/ p 0R Tmax T-T-T c/w RC_/ p 0R Tmax T-T-T c/w RC_/ p 0R Tmax T-T-T c/w RC_ p 0R X = Last product available A = Assembly reserved to ABB SACE skilled technician /8 ABB SACE SDC0000D00

54 Low voltage moulded-case circuit-breakers SD-VIEW series SD-VIEW ABB SACE /9 SDC0000D00

55 Low voltage moulded-case circuit-breakers SD-VIEW series SD-VIEW Caption ) SD-D/CA module ) SD-T module ) SD-M module Spare part description Type SDA code Q.ty Note SD-D/CA module SD-View 080R SD-T module SD-View 08R SD-M module SD-View 08R X = Last product available A = Assembly reserved to ABB SACE skilled technician /0 ABB SACE SDC0000D00

56 Low voltage air circuit-breakers OTOMAX series Otomax ABB SACE / SDC0000D00

57 Low voltage air circuit-breakers Withdrawable PC - PC OTOMAX PC - PC OTOMAX Operating mechanism and applications Otomax / ABB SACE SDC0000D00

58 Detail of extensions for withdrawable version Detail of withdrawable lever 0 0 Detail of front structure Otomax 9 ABB SACE / SDC0000D00

59 Low voltage air circuit-breakers Caption ) No. operating mechanism ) Levers kit including loading lever and grip + releases lever + Yc/Yo trip lever ) Spring for Otomax breaker ) Moving poles ) Moving arc contacts kit ) Fixed arc contacts kit ) Arc chambers set 8) Jaw contacts kit 9) Partitions and pole protections kit 0) Racking-out levers and rails kit ) Insulating supports kit c/w upper bars and fixing accessories for moving part ) Insulating supports kit c/w terminals and fixing accessories for fixed part ) Door flange and gasket ) Motor operator c/w mounting accessories, springs loaded and locking contact ) Undervoltage release ) Time delayer ) Single K serie relay 8) Auxiliary contacts board for fixed version 9) Electrical and mechanical signalisation for tripped releases 0) Opening release ) Closing release Otomax ) Padlock device ) Key lock ) Microswitch for electrical indication springs loaded (locking contact not included) ) Aux support + No/Nc auxiliary contacts for 0V version ) Single microswitch for auxiliary contacts board ) Sliding contacts kit_only 0V (on 00V version plug and socket) 8) Microswitch for INS/ISO position signalisation 9) Earthing plate + earthing contact 0) Tool case complete of taylor-made spanners and templates Note: For the identification of any other parts not included into the present catalogue, please get in touch with your local sales organization / ABB SACE SDC0000D00

60 Spare part description Type UXAB code Q.ty Note No. operating mechanism 0 00A /p 999 A () 0 00A p 9998 A () A /p 9999 A () A p 9990 A () P-P / A p 999 A () P-P / A p 999 A () Levers kit including loading lever and grip + Complete range 999 releases lever + Yc/Yo trip lever,kg single spring for Otomax breaker, type A Complete range see table below 0,Kg single spring for Otomax breaker, type B Complete range see table below Moving poles No. complete pole (Phases 0V _ Neutral pole of P-P, 0V) No. complete pole (Otomax P-P, 000A- 0V) or A () A () No. half-pole 0V) A () Moving arc contacts kit No. pcs for P 00V A No. 9 pcs for P 00V A No. pcs for P 00V A 9999 No. 0 pcs for P 00V 00 00A 9999 No. pcs for P/P 0V 0A 00A 9999 No. 8 pcs for P/P 0V 000A 00A 9999 No. 0 pcs for P/P 0V 00 00A 9999 Fixed arc contacts kit No. pcs for 00V Otomax P/P 9999 No. pcs for P 0V 0A 00A /p 9999 No. + pcs for P/P 0V 000A 00A /p Arc chambers set No. pcs for P/P 0V 00A 00A /p No. pcs for PC 00V No. pcs for 0 00A p (for all the 00V series + 0V P-P 0A-00A p) A A 999 () No. pcs 0 00A p (Un=0V) 999 No. pcs A p (Un=0V) 9998 No. pcs A p (Un=0V) 9999 No. pcs for 00 00A p (Un=0V + PC 00V from 00A to 000A) 9990 Half set for 0V Full set for 0V () Otomax Springs type matching table for N-NM operating mechanism. () Supplied w/out springs and black cover () Includes x moving arc-breaking contacts () Includes x moving arc-breaking contacts () Remove pole protections before assembly new arcing chambers 00 V p p Otomax P 000A-00A A + B 000A-00A B + A Otomax P 000A-00A B B 000A-00A B + A B 000A-00A B Otomax P 000A-00A B 000A-00A B 0 V p p Otomax P 0A-00A A + B B + A 000A-00A B + A B 00A-00A B + A Otomax P 000A-00A B 000A-00A B X = Last product available A = Assembly reserved to ABB SACE skilled technician ABB SACE / SDC0000D00

61 Low voltage air circuit-breakers Spare part description Type UXAB code Q.ty Note Otomax Jaw contacts kit No. 8 pcs for P/P 0A /p 9990 No. pcs for P/P 00A p 9990 No. 8 pcs for P/P 00A p 9990 No. pcs for P/P 000A p 9990 No. 8 pcs for P/P 000A p 9990 No. pcs for P/P 00A p 9990 No. 8 pcs for P/P 00A p 9990 No. pcs for P 00A No. pcs for P A No. pcs for P 000A p 9990 No. 8 pcs for P 000A p 999 No. pcs for P 00A p 999 No. 8 pcs for P 00A p 999 No. pcs for P 00A 999 No. pcs for P A 999 Partitions and pole protections kit 0A_00A p 999 0A_00A p A_00A p A_00A p 9998 P/P A p 9999 Racking-out levers and rails kit 0 00A 999 P-P, A 999 Insulating supports kit c/w upper bars and fixing accessories for moving part Insulating supports kit c/w terminals and fixing accessories for fixed part 0A p 999 A () 0A p 999 A () 00A p 999 A () 00A p 999 A () 000A p 999 A () 000A p 999 A () 00A p 999 A () 00A p 9998 A () P-P, 00A 9999 A () P-P, A 9990 A () 0A p 999 0A p A p A p A p A p A p A p 9998 P-P, 00A 9999 P-P, A 9990 Door flange and gasket Complete range Motor operator c/w mounting accessories, springs loaded and locking contact V AC/DC V AC/DC V AC/DC V AC/DC 9998 X -0V AC/DC V AC/DC V AC/DC 9998 X -0V AC/DC () Lower busbars not included X = Last product available A = Assembly reserved to ABB SACE skilled technician / ABB SACE SDC0000D00

62 Spare part description Type UXAB code Q.ty Note Undervoltage release V DC V DC V DC V DC V AC V AC V AC 9990 Time delayer - sec c/w Yc s enabling contact on YU sec c/w Yc s enabling contact on YU sec c/w Yc s enabling contact on YU 9990 Single K serie relay K relay type 0 00A 9990 () KS relay type 0 00A 9990 () KSI relay type 0 00A 9990 () K relay type A () KS relay type A () KSI relay type A () K relay type A () KS relay type A () KSI relay type A () Auxiliary contacts board Fixed version Electrical and mechanical signalisation for tripped releases Complete range Opening release 0V -8V DC -V AC V 8-0V DC V 00-V DC 00-0V AC V 80-0V DC 80-00V AC V -8V DC -V AC V 8-0V DC 00-V AC V 00-V DC 00-0V AC V 80-0V DC 80-00V AC 999 Closing release V DC V DC V DC V DC V AC 9990 V DC 0-0V AC V AC 9990 Padlock device Complete range 900 Key lock Complete range, for single circuit breaker 900 Complete range, for two or more circuit breakers 900 Microswitch for electrical indication springs loaded (locking contact not included) Aux support + No/Nc auxiliary contacts for 0V version Complete range 9990 No. No/Nc auxiliary contacts (higher position, right side) No. No/Nc auxiliary contacts (lower position, right side) No. No/Nc auxiliary contacts (higher position, left side) No. No/Nc auxiliary contacts (lower position, left side) Otomax () Calibrations values must be declared at ordering stage, for further details please refer to following pages. X = Last product available A = Assembly reserved to ABB SACE skilled technician ABB SACE / SDC0000D00

63 Low voltage air circuit-breakers Spare part description Type UXAB code Q.ty Note 8 9 Single microswitch for auxiliary contacts board Complete range 9990 Max 0 Sliding contacts kit_only 0V (on 00V version plug and socket) Complete range Microswitch for INS/ISO position signalisation Complete range 999 Max + Earthing plate + earthing contact Complete range Tool case complete of taylor-made spanners and templates Complete range Otomax X = Last product available A = Assembly reserved to ABB SACE skilled technician /8 ABB SACE SDC0000D00

64 Calibrations table K relais Type UXAB code Release rated current Circuit-breakers type Overload protection In PC PC I current setting ranges A I=(0. ) x In A Delayed short-circuit protection I current settings available ranges K K K B Example The right code for the order of a K release rated current 0 A - Delayed short-circuit protection is: UXAB 9990 UXAB Code Rated current (column A) Delayed short-circuit protection (column B) UXAB9990 Otomax ABB SACE /9 SDC0000D00

65 Low voltage air circuit-breakers Calibrations table KS relais Type UXAB code Release rated current Circuit-breakers type Overload protection In PC PC I current setting ranges I=(0. ) x In A Delayed short-circuit protection I current settings available ranges Fixed delays available A B C KS KS KS T S Example The right code for the order of a KS release rated current 00 A - Delayed short-circuit protection Fixed delays 0.s is: UXAB UXAB Code Rated current (column A) Delayed short-circuit protection (column B) Fixed delay (column C) UXAB Otomax /0 ABB SACE SDC0000D00

66 Calibrations table KSI relais Type UXAB code Release rated current Circuit-breakers type Overload protection In PC PC I current setting ranges Delayed short-circuit protection I current settings available ranges Fixed delays available Instantaneous shortcircuit protection Fixed values available I=(0. ) x In A T S I ka A B C D KSI KSI KSI Example The right code for the order of a KSI release rated current 00 A - Delayed short-circuit protection Fixed delays 0.s - Instantaneous trip set at 0 ka is: UXAB UXAB Code Rated current (column A) Overload protection (column B) Fixed delay (column C) I (column D) UXAB99909 Otomax ABB SACE / SDC0000D00

67

68 Low voltage air circuit-breakers NOVOMAX G0 series Novomax G0 ABB SACE / SDC0000D00

69 Low voltage air circuit-breakers Basic components 0 Novomax G / ABB SACE SDC0000D00

70 Caption ) No. Moving arc contacts kit ) No. Arc chambers kit ) Jaw contacts kit ) Closing springs set ) Motor operator c/w mounting accessories ) Sliding contacts for moving and fixed part (support not included) ) Closing release 8) Opening release 9) Undervoltage release 0) Single microswitch for auxiliary contacts board ) Microswitches kit including lock contacts, spings loaded contacts, tripped relais contacts ) Fixed arc contacts kit ) Single lower through bar ) Flange c/w gasket ) Key lock in open position ) Indicators/pushbuttons kit including K releases tripping lever and YU-YO trip lever ) No + plug In/Out positions contacts 8) Mechanical and electrical indication tripped releases 9) Auxiliary contacts terminal board (only for FIXED version) 0) Single K serie relay Novomax G0 ABB SACE / SDC0000D00

71 Low voltage air circuit-breakers Spare part description Type UXAB code Q.ty Note Novomax G No. Moving arc contacts kit Complete range No. Arc chambers kit Complete range Jaw contacts kit No. 8 pcs 800 0A /p 9990 No. pcs for 00A p 9990 No. 8 pcs 00A p 9990 Closing springs set Complete range 9990 Motor operator c/w mounting accessories V DC 9990 X 8V DC 9990 X 0V DC/AC X Sliding contacts for moving and fixed part (support Complete range not included) Closing release V DC 990 8V DC 990 0V DC V DC 998 0V AC 999 0V AC V AC 99 Opening release V DC 990 8V DC 990 0V DC V AC 999 0V AC 998 0V DC V AC 99 Undervoltage release V DC 990 8V DC 990 0V DC V DC 998 0V AC 999 0V AC V 0Hz - 0V 0Hz 99 Single microswitch for auxiliary contacts board Complete range, upper microswitches 9990 Max 9 Complete range, lower microswitches Max 9 Microswitches kit including lock contacts, spings loaded contacts, tripped relais contacts Complete range Fixed arc contacts kit No. contacts 800 0A /p 9990 No. contacts 00A p 9990 No. contacts 00A p 9990 Single lower through bar 800 0A 9990 or A 00A ( turns) 9990 or A 0A ( turns) 9990 or A 00A ( turns) 9990 or A 00A 9990 or A Flange c/w gasket Complete range 900 Key lock in open position Complete range 9000 Indicators/pushbuttons kit including K releases tripping lever and YU-YO trip lever Complete range X = Last product available A = Assembly reserved to ABB SACE skilled technician / ABB SACE SDC0000D00

72 Spare part description Type UXAB code Q.ty Note No + plug In/Out positions contacts Complete range, p Complete range, p Mechanical and electrical indication tripped releases Complete range 900 Auxiliary contacts terminal board (only for FIXED version) Complete range 900 Single K serie relay K type 9000 () KS type 9000 () KSI type 9000 () Novomax G0 () It is essential to complete the code for the purchase order with the information shown on the next pages, to fully specify which relay is required. X = Last product available A = Assembly reserved to ABB SACE skilled technician ABB SACE / SDC0000D00

73 Low voltage air circuit-breakers Calibrations table K relais 0 NOVOMAX G0 Release rated current Circuit-breakers type Overload protection Delayed short-circuit protection Type UXAB code In G0 800 G0 0 G0 00 I current settings ranges I current settings available ranges I = (0. ) x In A K X X X X X X X X X X X B Example The right code for the order of a K release rated current 0 A - Delayed short-circuit protection is: UXAB 9000 UXAB Code Rated current (column A) Delayed short-circuit protection (column B) UXAB9000 Novomax G0 /8 ABB SACE SDC0000D00

74 Calibrations table KS relais 0 NOVOMAX G0 Type UXAB code Release rated current In Circuit breakers type G0 800 G0 0 G0 00 Overload protection I current settings ranges I=(0. ) x In Delayed short-circuit protection I current settings available ranges Fixed delays available T (sec) A B C KS X X X X X X X X X X X Example The right code for the order of a KS release rated current 800 A - Delayed short-circuit protection is - Fixed delays 0.s is: UXAB 9000 UXAB Code Rated current (column A) Delayed short-circuit protection (column B) Fixed delay (column C) UXAB9000 Novomax G0 ABB SACE /9 SDC0000D00

75 Low voltage air circuit-breakers Calibrations table KSI relais 0 NOVOMAX G0 Type UXAB code Release rated current In Circuit breakers type G0 800 G0 0 G0 00 Overload protection I current settings ranges Delayed short-circuit protection I current settings available ranges Fixed delays available Instantaneous shortcircuit protection Fixed values available I=(0. ) x In T (sec) I (ka) A B C D KSI X X X X X X X X X X X Example The right code for the order of a KSI release rated current 800 A - Delayed short-circuit protection is - Fixed delays 0.s - I 0 ka is: UXAB 9000 UXAB Code Rated current (column A) Delayed short-circuit protection (column B) Fixed delays (column C) I value (column D) UXAB9000 Novomax G0 /0 ABB SACE SDC0000D00

Tmax MCCBs. Molded case circuit breakers. Tmax

Tmax MCCBs. Molded case circuit breakers. Tmax Molded case circuit breakers Introduction ABB is once again demonstrating its commitment to new product development and its superiority in product performance. Never before has the industry seen such high

More information

Technical catalogue - Ordering Codes. SACE Tmax XT New low voltage moulded-case circuit-breakers up to 250 A 50 C rated

Technical catalogue - Ordering Codes. SACE Tmax XT New low voltage moulded-case circuit-breakers up to 250 A 50 C rated Technical catalogue - Ordering Codes SACE Tmax XT New low voltage moulded-case circuit-breakers up to 250 A 50 C rated New SACE Tmax XT. Simply XTraordinary. Today a highly advanced range of circuit-breakers

More information

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application. Low voltage Direct Current Network Compact NSX DC PV Circuit breakers and switch disconnectors for solar application Catalogue 2012 Compact NSX DC PV A complete DC offer for solar application from 80

More information

SENTRON Switching and Protection Devices Air Circuit Breakers

SENTRON Switching and Protection Devices Air Circuit Breakers Siemens AG 9 SENTRON Switching and rotection Devices Air Circuit reakers 5 5/ Introduction 3WL Air Circuit reakers 3WL Air Circuit reakers/ Non-Automatic Air Circuit reakers up to 63 A (AC) 5/6 General

More information

Motor circuit-breakers

Motor circuit-breakers Thermal-magnetic motor circuit-breakers type GV2-M GV2-M Thermal-magnetic motor circuit-breakers GV2-M Pushbutton control Standard power ratings Setting Magnetic Thermal Reference Weight of 3-phase motors

More information

R.C.C.B. s two-pole LEXIC

R.C.C.B. s two-pole LEXIC 87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s two-pole LEXIC 089 06/09/10/11/12/15/16/17/18/ 27/28/29/30/35, CONTENTS PAGES 1. Electrical and mechanical characteristics...

More information

UniGear ZS1. Medium voltage, arc proof, air insulated switchgear for primary distribution

UniGear ZS1. Medium voltage, arc proof, air insulated switchgear for primary distribution UniGear ZS1 Medium voltage, arc proof, air insulated switchgear for primary distribution UniGear ZS1: an innovative solution for all installation requirements ABB UniGear is medium voltage metal-clad,

More information

Breaking and protection devices

Breaking and protection devices Breaking and protection devices 05 POWER GUIDE 2009 / BOOK 05 INTRO The purpose of selecting a protection device is to perform two essential functions: to protect people and to protect trunking, while

More information

SIRCOVER. Manual changeover switches from 125 to 3200 A. Changeover switches. Function. Advantages. The solution for.

SIRCOVER. Manual changeover switches from 125 to 3200 A. Changeover switches. Function. Advantages. The solution for. The solution for Changeover switches svr_099_b_1_cat > Manufacturing industry. > Power distribution. 3200 Strong points svr_059_a_1_cat > complete range. > Easy connections. > Stable positions. > mproved

More information

Electrical auxiliaries 0 For i DPN (DPN), C60 and C120

Electrical auxiliaries 0 For i DPN (DPN), C60 and C120 Circuit protection For i DPN (DPN), C60 and C120 Function They remotely trip or indicate circuit-breakers, with or without Vigi module. Description b They are mounted to the left of the circuit-breaker

More information

NEXT SOLUTION EXPERT SOLUTION EXCELLENT SOLUTION. Super Solution

NEXT SOLUTION EXPERT SOLUTION EXCELLENT SOLUTION. Super Solution NEXT SOLUTION EXPERT SOLUTION EXCELLENT SOLUTION Super Solution Low voltage circuit breakers Susol LV circuit breakers Super Solution Contents Overview Electrical characteristics Trip units Accessories

More information

Emax DC. Annex to the technical catalogue. Low voltage Switch-disconnectors and Automatic circuit-breakers for Direct Current Applications

Emax DC. Annex to the technical catalogue. Low voltage Switch-disconnectors and Automatic circuit-breakers for Direct Current Applications Annex to the technical catalogue Emax DC Low voltage Switch-disconnectors and Automatic circuit-breakers for Direct Current Applications 1SDC200012D0201 Index SACE Emax DC automatic circuit-breakers...

More information

Circuit Breakers. Next Generation of Protection Capabilities

Circuit Breakers. Next Generation of Protection Capabilities Circuit Breakers Next Generation of Protection Capabilities Circuit Breaker Offering Rockwell Automation offers a full line of Allen-Bradley circuit breakers and motor protection devices to help meet many

More information

ISL Insulation monitoring devices Continuous monitoring of IT systems from photovoltaic to industrial applications.

ISL Insulation monitoring devices Continuous monitoring of IT systems from photovoltaic to industrial applications. ISL Insulation monitoring devices Continuous monitoring of IT systems from photovoltaic to industrial applications. Ensuring operational continuity To ensure the operational continuity of an electrical

More information

White Paper - July 2012. ATS021-ATS022 Automatic transfer switching

White Paper - July 2012. ATS021-ATS022 Automatic transfer switching White Paper - July 202 02-022 Automatic transfer switching 02-022 Automatic transfer switching Index. Introduction...2 2. Description of... Switching logics...6 Transformer for the main and generator

More information

Technical catalogue. Low-voltage moulded-case circuit-breakers. 604050/012 en ABB SACE

Technical catalogue. Low-voltage moulded-case circuit-breakers. 604050/012 en ABB SACE Technical catalogue Low-voltage moulded-case circuit-breakers 604050/02 en Contents Presentation Main features 2 Ranges Accessories 4 Characteristic curves and technical information 5 Dimensions and circuit

More information

IZM ACB/Circuit-breakers. Robust safety. Extract from Main Catalogue HPL2010 IZM26 Circuit-breakers IN26 Switch-disconnectors

IZM ACB/Circuit-breakers. Robust safety. Extract from Main Catalogue HPL2010 IZM26 Circuit-breakers IN26 Switch-disconnectors IZM ACB/Circuit-breakers Robust safety Extract from Main Catalogue HPL2010 IZM26 Circuit-breakers IN26 Switch-disconnectors t [s] 0.1 0.05 0.04 0.03 0.02 0.01 20 1230DIA-125 (70C1043) 30 40 50 60 80 100

More information

Technical catalog. FORMULA UL New low voltage molded case circuit breakers up to 250A. Power and productivity for a better world TM

Technical catalog. FORMULA UL New low voltage molded case circuit breakers up to 250A. Power and productivity for a better world TM Technical catalog FORMULA UL New low voltage molded case circuit breakers up to 2A Power and productivity for a better world TM Index Main characteristics 1 Circuit breakers for power distribution 2 Accessories

More information

Emax UL Listed ABB SACE. Installation, service and maintenance instructions for low voltage air power circuit breakers

Emax UL Listed ABB SACE. Installation, service and maintenance instructions for low voltage air power circuit breakers Installation and service instructions Installation, service and maintenance instructions for low voltage air power circuit breakers Listed ABB SACE Dis. App. Uff. Resp. Uff. Utilizz. Title Installation,

More information

Low Voltage Products. Switches Automatic Transfer Switches

Low Voltage Products. Switches Automatic Transfer Switches Low Voltage Products Switches Automatic Transfer Switches Growing importance of a secure power supply Standby power is an integral part of many industrial and domestic electrical systems. High energy prices,

More information

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV.00 2012.4

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV.00 2012.4 CE - BF - C - en - REV.00 2012.4 APPLICATION CE-BF Switchbords up to 40.5 kv are designed for use in public and industrial distribution system up to 40,5KV for the operation and protection of lines, transformers,

More information

Molded Case Circuit Breakers, Motor Protection Circuit Breakers, and Motor Circuit Protectors. Technical Data

Molded Case Circuit Breakers, Motor Protection Circuit Breakers, and Motor Circuit Protectors. Technical Data Molded Case Circuit Breakers, Motor Protection Circuit Breakers, and Motor Circuit Protectors Technical Data Table of Contents Introduction... 4 Definitions... 5 Product Range... 8 Product Line Overview...11

More information

Masterpact NW Circuit breakers and switch-disconnectors from 800 to 6300 A

Masterpact NW Circuit breakers and switch-disconnectors from 800 to 6300 A Low voltage electrical distribution Masterpact NW Circuit breakers and switch-disconnectors from 800 to 6300 A User manual 09/2009 User manual for circuit breakers and switch-disconnectors Masterpact

More information

3RV Motor Starter Protectors up to 100 A

3RV Motor Starter Protectors up to 100 A General data Overview S0 motor 3RV1 motor are compact, current limiting motor which are optimized for load feeders. The motor are used for switching and protecting three-phase induction motors of up to

More information

Electronic overload relay EF19 and EF45

Electronic overload relay EF19 and EF45 Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor

More information

Plug and Socket Devices CES 63 A Series 8579

Plug and Socket Devices CES 63 A Series 8579 www.stahl.de > Switch socket / plug 63 A > Large switch handle with clear switch position indication padlockable in 0- and I-position > Low insertion and withdrawal forces through individually encapsulated

More information

3K Load-Break Switches The Program for Safety and Performance. sentric

3K Load-Break Switches The Program for Safety and Performance. sentric 3K Load-Break Switches The Program for Safety and Performance sentric Whether for reliable switching and isolation under load, or for protection against overload or short-circuits our 3K range of load-break

More information

Circuit Breakers. NRC Series. NRC Series. 900 www.idec.com

Circuit Breakers. NRC Series. NRC Series. 900 www.idec.com Switches & Pilot Lights Display Lights NRC series circuit breakers offer circuit protection which is far superior to using fuses in applications containing relay circuits, motor circuits, heater circuits,

More information

Tmax. Technical catalogue. Low voltage moulded-case circuit-breakers up to 630 A 1SDC210004D0204

Tmax. Technical catalogue. Low voltage moulded-case circuit-breakers up to 630 A 1SDC210004D0204 Technical catalogue Tmax Low voltage moulded-case circuit-breakers up to 630 A 1SDC210004D0204 VERVIEW MAIN CHARACTERISTICS THE RANGES ACCESSORIES CHARACTERISTIC CURVES AND TECHNICAL INFORMATION WIRING

More information

Installation and service instructions. Installation, service and maintenance instructions for low voltage air circuit-breakers. Emax 1SDH000460R0002

Installation and service instructions. Installation, service and maintenance instructions for low voltage air circuit-breakers. Emax 1SDH000460R0002 Installation and service instructions Installation, service and maintenance instructions for low voltage air circuit-breakers Dwg. App. Model L2234 Resp. Off. Take over Off. ABB SACE Title Apparatus Doc.

More information

Franco Vecchiato, SAM LPBS Regional Manager New SACE Emax 2 From Circuit-breaker to Power Manager

Franco Vecchiato, SAM LPBS Regional Manager New SACE Emax 2 From Circuit-breaker to Power Manager Franco Vecchiato, SAM LPBS Regional Manager New SACE Emax 2 From Circuit-breaker to Power Manager SACE Emax 2 From Circuit-Breaker to Power Manager Our customers need more efficient solutions, to Increase

More information

Current and voltage measuring relays

Current and voltage measuring relays Current and voltage measuring relays RXIK 1, RXEEB 1 and Page 1 Issued June 1999 Changed since July 1998 Data subject to change without notice RXIK 1 RXEEB 1 (SE980082) (SE980081) (SE970869) Features Application

More information

BRITISH STYLE SEMICONDUCTOR PROTECTION FUSES

BRITISH STYLE SEMICONDUCTOR PROTECTION FUSES The Edison British Style semiconductor protection fuses include a 660VAC line utilizing new filler technology. These new fuses have greatly reduced peak let-through current and energy under fault conditions

More information

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance SPECIFICATION FOR LOW VOLTAGE SWITCHBOARD SEN I N D E X Description 10 STANDARD TECHNICAL REQUIREMENTS 11 Standards 12 General Operating Conditions 13 General Description Of Switchboard 131 Structure 132

More information

Medium Voltage Products. PR512 Microprocessor-based self-supplied protection relays

Medium Voltage Products. PR512 Microprocessor-based self-supplied protection relays Medium Voltage Products PR512 Microprocessor-based self-supplied protection relays DESCRIPTION CHARACTERISTICS AND ORDERING CODES PR512/P (50-51) UNIT PR512/P (50-51-50N-51N) UNIT PR512/PD (50-51-50N-51N

More information

Bolted contact switches. Pringle switches

Bolted contact switches. Pringle switches Bolted contact switches Pringle switches Eaton s Pringle bolted contact switches History Eaton s PringleT switches have helped pioneer the development of high-quality electrical products for commercial

More information

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors PRODUCT GUIDE SL Medium Voltage IEC Vacuum Contactors Table of Contents 1 Overview Introduction....................................................2 Features........................................................2

More information

QUICK REFERENCE PRICE GUIDE JULY 2015

QUICK REFERENCE PRICE GUIDE JULY 2015 QUICK REFERENCE PRICE GUIDE JULY 2015 ISO 9001: 2008 OUR CUSTOMER CARE COMMITMENTS Quality is Guaranteed All products supplied from this Quick Price Guide carry a guarantee against defects in materials

More information

CUSTOMER CLASS FILE. ABB STOTZ-KONTAKT GmbH 3215-30 098793_0_000

CUSTOMER CLASS FILE. ABB STOTZ-KONTAKT GmbH 3215-30 098793_0_000 Seite 1 von 6 Certification Record CUSTOMER CLASS FILE ABB STOTZ-KONTAKT GmbH 3215-30 098793_0_000 Eppelheimer Strasse 82, SUPPLEMENTARY PROTECTORS- COMPONENT ACCEPTANCE PROGRAM Heidelberg Baden-Wurttemberg

More information

RCD Type F Residual current protection for single phase inverters applications

RCD Type F Residual current protection for single phase inverters applications RCD Type F Residual current protection for single phase inverters applications Type F: a new RCD type to ensure complete safety ABB introduces the Type F Residual Current Devices, dedicated to the protection

More information

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original A motor starter is a combination of devices to allow an induction motor to start, run and stop according

More information

Index. 17 - Molded case circuit breakers. Molded case circuit breakers. Tmax UL489B Photovoltaic circuit breakers...17.67-17.70

Index. 17 - Molded case circuit breakers. Molded case circuit breakers. Tmax UL489B Photovoltaic circuit breakers...17.67-17.70 Molded case circuit breakers Index Molded case circuit breakers - Molded case circuit breakers Formula...1 -.10 General information Introduction...1 Circuit breakers for power distribution...2 explanation...3

More information

3AH5 Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG 11.05 2010

3AH5 Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG 11.05 2010 Medium-Voltage Equipment Selection and Ordering Data Catalog HG 11.05 2010 Answers for energy. R-HG11-172.tif 2 Siemens HG 11.05 2010 Contents Contents Page 3AH5 Vacuum Circuit-Breakers Medium-Voltage

More information

Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M

Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M The details make the difference MCB S 200/S 200 M A range designed to ensure efficiency and protection

More information

Manual Motor Starter MS 116 up to 16 A Technical Data

Manual Motor Starter MS 116 up to 16 A Technical Data Manual Motor Starter MS 116 up to 16 A Technical Data Type MS 116 Standards: Major International IEC 60 947-4-1 / IEC 60 947-2 and European Standards EN 60 947-4-1 / EN 60 947-2 Approvals, Certificates

More information

New SACE Emax 2 for UL 1066 From Circuit Breaker to Power Manager

New SACE Emax 2 for UL 1066 From Circuit Breaker to Power Manager New SACE Emax 2 for UL 1066 From Circuit Breaker to Power Manager 2 1SDC200039B0201 New SACE Emax 2 for UL 1066 Circuit breakers switch power SACE Emax 2 manages it. SACE Emax 2 is the new benchmark of

More information

Low Voltage. EasyPact CVS. Moulded-case circuit breakers and switch-disconnectors from 100 to 630 A. Catalogue 2011

Low Voltage. EasyPact CVS. Moulded-case circuit breakers and switch-disconnectors from 100 to 630 A. Catalogue 2011 Low Voltage EasyPact CVS Moulded-case circuit breakers and switch-disconnectors from 100 to 630 A Catalogue 2011 Safe Reliable Simple The easy choice for quality and value EasyPact CVS LV circuit breakers

More information

General information Circuit breakers for power distribution T1 T3

General information Circuit breakers for power distribution T1 T3 Circuit breakers for power distribution T1 T3 T1 T2 T3 T1 1P T1 T2 T3 UL 489 CSA C22.2 Frame size A 100 100 100 225 Number of poles Nr 1 3, 4 3, 4 3, 4 Rated voltage AC (50-60 Hz) V 277 600Y / 347V 480

More information

The following components are common to most cubicles; this example is an ABB HK cubicle.

The following components are common to most cubicles; this example is an ABB HK cubicle. 4.0 CIRCUIT BREAKER CUBICLE Learning Objectives The circuit breaker cubicle is the component of the switchgear that holds the circuit breaker, and the controls and cabling for the distribution system.

More information

ELR: ABB range of front panel residual current relays Protection device according to IEC/EN 60947-2 Annex M

ELR: ABB range of front panel residual current relays Protection device according to IEC/EN 60947-2 Annex M ELR: ABB range of front panel residual current relays Protection device according to IEC/EN 60947-2 Annex M Tested, certified, reliable Network monitoring and protection The electronic residual current

More information

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils

More information

CAS 36 Ring Main Unit

CAS 36 Ring Main Unit Power distribution networks Ring Main Unit Catalogue 2008 A new path for achieving your electrical installations A comprehensive offer The range is part of a comprehensive offer of products that are perfectly

More information

ABB solutions for photovoltaics Protection and other modular devices

ABB solutions for photovoltaics Protection and other modular devices ABB solutions for photovoltaics Protection and other modular devices 2 ABB Component supplier for residential and power plant application ABB has been working for many years, as both a manufacturer and

More information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC

More information

Multi-Protocol decoder 76 200 with Load regulation

Multi-Protocol decoder 76 200 with Load regulation Multi-Protocol decoder 76 2 with Load regulation For locomotives with universal motors on digital layouts operating in the DCC and Motorola data format. Features 76 2 Load regulated multi-protocol decoder

More information

LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE

LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE 380/415/690 Volt AC 50/65/80/100 ka 1. Product Guide Low Voltage Motor Control Centre CONTSTRUCTION Continuous "poured in place" gasket

More information

Unified requirements for systems with voltages above 1 kv up to 15 kv

Unified requirements for systems with voltages above 1 kv up to 15 kv (1991) (Rev.1 May 2001) (Rev.2 July 2003) (Rev.3 Feb 2015) Unified requirements for systems with voltages above 1 kv up to 15 kv 1. General 1.1 Field of application The following requirements apply to

More information

Medium Voltage Products. ZN1 12 kv arc-proof air-insulated switchgear for primary distribution

Medium Voltage Products. ZN1 12 kv arc-proof air-insulated switchgear for primary distribution Medium Voltage Products ZN1 12 kv arc-proof air-insulated switchgear for primary distribution ZN1 an innovative switchgear for power distribution requirements ABB ZN1 primary distribution switchgear is

More information

PSR The compact range Description

PSR The compact range Description Description The PSR range is the most compact of all the ABB softstarter ranges, thereby making it possible to fit many devices into the same enclosure. The system concept with Manual Motor Starters provides

More information

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear Mini Motor Contactor J7KNA ) Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN-rail) Range from 4 to 5.5 (AC 3, 380/415V) 4 -main pole version (4 AC

More information

OVERCURRENT & EARTH FAULT RELAYS. To study the protection of equipment and system by relays in conjunction with switchgear.

OVERCURRENT & EARTH FAULT RELAYS. To study the protection of equipment and system by relays in conjunction with switchgear. OVERCURRENT & EARTH FAULT RELAYS Objective: To study the protection of equipment and system by relays in conjunction with switchgear. Theory: The function of a relay is to detect abnormal conditions in

More information

Technical catalogue - 2015.10. SACE Tmax XT New low voltage moulded-case circuit-breakers up to 250 A

Technical catalogue - 2015.10. SACE Tmax XT New low voltage moulded-case circuit-breakers up to 250 A Technical catalogue - 2015.10 SACE Tmax XT New low voltage moulded-case circuit-breakers up to 250 A Construction Characteristics 1 The SACE Tmax XT Ranges 2 Accessories 3 Characteristic Curves and Technical

More information

GE Power Controls. MiniFORM Switchboards

GE Power Controls. MiniFORM Switchboards GE Power Controls MiniFORM Switchboards MiniFORM MiniFORM MiniFORM switchboards Arrangement Modules Arrangement modules 1-6 6 Arrangement modules 7-12 7 Arrangement modules 12-14 8 Arrangement modules

More information

Catalog. Arc Guard System TM TVOC-2

Catalog. Arc Guard System TM TVOC-2 Catalog Arc Guard System TM TVOC-2 Introduction An even better Arc Guard System TVOC-2, ABB s latest Arc Monitor, builds on the well known TVOC design. Its new functions and features improve an already

More information

W DATA SHEET: RESIDUAL CURRENT CIRCUIT BREAKER 25-100A, SERIES BCF0 AND BCF6

W DATA SHEET: RESIDUAL CURRENT CIRCUIT BREAKER 25-100A, SERIES BCF0 AND BCF6 W DATA SHEET: RESIDUAL CURRENT CIRCUIT BREAKER 25-100A, SERIES BCF0 AND BCF6 W SCHRACK-INFO Any mains connection If using 4-pole. switches with 3 or 2-poles, ensure connection acc. to assembly instructions

More information

Data Sheet. Electro-mechanical counters Hengstler 800 series

Data Sheet. Electro-mechanical counters Hengstler 800 series Data Pack D Issued March 00 504897 Data Sheet Electro-mechanical counters Hengstler 800 series The 800 series totalising and predetermining batch counters, manufactured by Hengstler, is available from

More information

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

Submit shop drawings for equipment provided under this section Shop drawings shall indicate: Section 16435 - SWITCHBOARDS Introduction Part 1 - General Reference The work under this section is subject to requirements of the Contract Documents including the General Conditions, Supplementary Conditions,

More information

Softstarters Type PSR

Softstarters Type PSR Catalog Softstarters Softstarters ABB Softstarters General To the left: A combination with PSR and a manual Motor Starter MS116 Above: PSR16, PSR30 and PSR 45 1 ABB Automation Products serve customers

More information

SC351. Model: SC351 NIL. Part List US-English

SC351. Model: SC351 NIL. Part List US-English Model: NIL Part List US-English Table of Contents GENERAL VIEW 3 COVER AND TANKS 5 FRAME SYST 7 HANDLE SUPPORT SYST 9 HANDLE SYST 12 MOTOR AND DECK SYST 15 BRUSH DECK SYST 17 ACCESSORIES 19 WIRING DIAGRAM

More information

Bussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1

Bussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1 How to configure Part Numbers: Step : Select Switch Amperage Power Module Switch Rating (Amps) Power Module Switch Catalog No. 30 3 60 6 00 200 2 400 4 Step 2: Select Options Needed 5 Bussmann Power Module

More information

IEC style contactors - long electrical and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide

IEC style contactors - long electrical and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide - long al and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide range coils +0% to -30% Finger safe terminals Four-pole versions available NO + NC and

More information

How can a charging station for electric vehicles be set up simply and safely?

How can a charging station for electric vehicles be set up simply and safely? SB18 Building > Electromobility > Charging Station Design How can a charging station for electric vehicles be set up simply and safely? Requirement In order to supply electric vehicles with electric power,

More information

3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,

3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V, Automation Technology > Industrial Controls > Switching Devices > Contactors and Contactor Assemblies > Power Contactors for Switching Motors > Contactors SIRIUS 3RT10, 3-pole, 3... 250 kw 3RT1015-1BB41

More information

Catalogue May 2015. EasyLine XLP Fuse Switch Disconnector 1-2-3-4 pole

Catalogue May 2015. EasyLine XLP Fuse Switch Disconnector 1-2-3-4 pole Catalogue May 2015 EasyLine XLP Fuse Switch Disconnector 1-2-3-4 pole Contents Introduction 1 Overview 1-pole 2 Overview 2-pole 3 Overview 3-pole 4 Overview 4-pole 5 Electronic Fuse Monitoring 6 Busbar

More information

Series 8146/5-V37 and Series 8150/5-V37

Series 8146/5-V37 and Series 8150/5-V37 www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection

More information

Technical data. RCBO s DS 261 / DS 271 Residual current operated circuit breakers with integral overcurrent protection

Technical data. RCBO s DS 261 / DS 271 Residual current operated circuit breakers with integral overcurrent protection Technical data RCBO s DS 261 / DS 271 Residual current operated circuit breakers with integral overcurrent protection When connecting aluminium conductors ensure that the contact surfaces of the conductors

More information

Bimetallic Overload Relay Specifications

Bimetallic Overload Relay Specifications Technical Data Bimetallic Overload Relay Specifications Bulletin Number 193K, 193T1 Topic Page Product Overview 2 Standards compliance and Certifications 2 General Specifications 193K 3 Approximate Dimensions

More information

ABB PSPS Erich Steinmann; Generator control-2013

ABB PSPS Erich Steinmann; Generator control-2013 ABB PSPS Erich Steinmann; Generator control-2013 GENERATOR CONTROL THE MODULAR SOLUTION FOR GENERATORS To make sure that power is efficiently converted into electric energy, it is necessary to supervise

More information

7.1. Part Lists. Hardware Insertion Machine. Instructions. Instructions

7.1. Part Lists. Hardware Insertion Machine. Instructions. Instructions Instructions Instructions The Parts in this section of the manual are listed by Item Number, Part Number, Description and Quantity. The Item Numbers are in a circle with an arrow pointing to the specific

More information

Electronic overload relay EF65, EF96 and EF146

Electronic overload relay EF65, EF96 and EF146 Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays.

More information

Our brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy

Our brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy Our brand A strong brand for strong products: The ENERGOLINE brand represents our product portfolio of INDUSTRIAL SWITCHGEAR SYSTEMS. Our products are characterized by a high degree of safety, flexibility

More information

Brochure April 2012. Moulded-case circuit-breakers overview SACE Tmax

Brochure April 2012. Moulded-case circuit-breakers overview SACE Tmax Brochure April 0 Moulded-case circuit-breakers overview SACE Tmax A single family of moulded-case circuit-breakers up to 00 A Tmax moulded-case circuit-breakers guarantee an extremely high performance

More information

The Intelligent AX1 Switchgear for Medium Voltage

The Intelligent AX1 Switchgear for Medium Voltage The Intelligent AX1 Switchgear for Medium Voltage Leif Lundin, Manager of Research and Development, Division Medium Voltage and Compact Substations, ABB Distribution, Sweden Abstract The newly launched

More information

Eaton Safety & Reliability Solutions in the Oil & Gas Industry Electrical

Eaton Safety & Reliability Solutions in the Oil & Gas Industry Electrical Eaton Safety & Reliability Solutions in the Oil & Gas Industry Electrical Victor Lee Commercial Marketing Manager SEA Eaton Oil & Gas Solution Tech Day 2013 Eaton. All Rights Reserved. Eaton is a leading

More information

REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16

REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16 REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16 Manually Operated Electronic Speed Controller Single Phase For all applications using suitably specified single-phase induction motor fans 1 GENERAL The

More information

Medium Voltage Products. V-Contact Medium voltage vacuum contactors

Medium Voltage Products. V-Contact Medium voltage vacuum contactors Medium Voltage Products V-Contact Medium voltage vacuum contactors DESCRIPTION CONTACTOR SELECTION AND ORDERING 2 UNIMOTOR ENCLOSURE SELECTION AND ORDERING POWERCUBE UNITS SPECIFIC PRODUCT CHARACTERISTICS

More information

How To Operate A Gec Transfer Switch Open Transition 40 2000 Amp Power Supply

How To Operate A Gec Transfer Switch Open Transition 40 2000 Amp Power Supply GTEC Transfer switch open transition 40 2000 amp Description GTEC transfer switches combine reliability and flexibility in a small, economical package for transferring loads between a utility and a generator

More information

3.0 CHARACTERISTICS. AR Auxiliary Relay High Speed, High Threshold 41-759.3C

3.0 CHARACTERISTICS. AR Auxiliary Relay High Speed, High Threshold 41-759.3C 41-759.3C the magnetic core upon energizing of the switch. When the switch closes, the moving contacts bridge two stationary contacts, completing the trip circuit. Also during this operation two fingers

More information

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624 PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624 v.1.0 AC/AC power supply unit Edition: 1 from 24 th October 2008 Supercedes edition: ---------- 10062009 CONTENTS: 1. Technical description. 1.1. General description

More information

Pilot-wire differential relay for lines with two or more terminals

Pilot-wire differential relay for lines with two or more terminals Pilot-wire differential relay for lines with two or more terminals Page 1 Issued: March 2003 Revision: A Data subject to change without notice Pilot-wire differential relay with RXHL 401 Features Phase

More information

TriLine ASSEMBLY System PowerModules

TriLine ASSEMBLY System PowerModules 04 2012 TriLine ASSEMBLY System PowerModules TriLine ASSEMBLY system Contents Introduction The new modular system intelligence 2 Delivery formats 8 EDS PowerCon configuration software 10 Technical specifications

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 2494434 (012730_C_000) Issued to: Siemens AG DF CP R&D V 3 Werner-von-Siemens-Strasse 48 Amberg, 92224 GERMANY Attention: Michael Schroeck The products listed below

More information

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of

More information

UFES Active protection for switchgear

UFES Active protection for switchgear Active protection for switchgear ABB AG Oberhausener Strasse 4047 Ratingen, Germany Phone: +49 0-0 Fax: +49 0-7 77 Note: We reserve the right to make technical changes or modify the contents of this document

More information

MasterINTERFACE 39 Series - Relay interface modules

MasterINTERFACE 39 Series - Relay interface modules MasterINTERFACE 39 Series - Relay interface modules Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy

More information

Low voltage circuit breakers. Working with trip characteristic curves

Low voltage circuit breakers. Working with trip characteristic curves Low voltage circuit breakers Working with trip characteristic curves Index 1. Introduction... 2 2. Main Definitions... 3 3. ABB Low Voltage Circuit Breakers complying with the Standards UL 489 and UL

More information

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual

More information

T 3000. Substation Maintenance and Commissioning Test Equipment

T 3000. Substation Maintenance and Commissioning Test Equipment T 3000 Substation Maintenance and Commissioning Test Equipment Multi function system for testing substation equipment such as: current, voltage and power transformers, all type of protection relays, energy

More information

Permissible ambient temperature Operation Storage, transport

Permissible ambient temperature Operation Storage, transport The Sitras PRO combined DC protective unit and controller is used in the power supply for DC railways in mass transit and main-line systems up 3,000 V DC. It protects DC switch gear and contact line systems

More information

Technical catalogue. Low voltage air circuit-breakers. SACE Emax. 604019/011 en March '99. 690 V 800-6300 A 40-150 ka (380/415 V) ABB SACE L.V.

Technical catalogue. Low voltage air circuit-breakers. SACE Emax. 604019/011 en March '99. 690 V 800-6300 A 40-150 ka (380/415 V) ABB SACE L.V. Technical catalogue 604019/011 en March '99 Low voltage air circuit-breakers SACE Emax 690 V 800-6300 A 40-150 ka (380/415 V) ABB SACE L.V. GENERAL INDEX Introduction Technology and innovation for advanced

More information