ROLLING STOCK CABLES

Similar documents
Catalogue Câbles d Energie

Global cable expertise for rolling stock

FIRE RESISTANT CABLE CONSTRUCTION OF CABLES

L304 LED PUSHBUTTON SWITCH / DISPLAY INDICATOR INDICATEUR LUMINEUX A LED / BOUTON POUSSOIR

RADOX railway cables acc. to EN and EN Edition 2009

FLEXIBLE INDUSTRIAL CABLES H07RN-F TENAFLEX SR

The Quality Connection. BETAflam Fire Resistant Safety Cables

Fire Resistant Cables

CONFLEX ELECTRIC CABLE

ENERGY. TECWATER S1BN8-F 0,6/1 kv. Cable for Water Application

ENERGY. TECSUN DUO (PV) Twin Cables for Photovoltaics

We specialize in low voltage cables including: Stranded Single Cable H07V-R Flexible Single Cable H05V-K

VIPERFLEX ELECTRIC CABLE

6 ELECTRICAL PARAMETERS

BETAtrans. Cables and Systems for Rolling Stock. Edition 2006

Capteur température et humidité pour HVAC

S1VF Sonde à visser avec tête de raccordement Threaded probe with terminal head

MEDIUM VOLTAGE POWER CABLES

Power Distribution System. Additional Information on page 2 See Page 2 Page 6. Eaton. See Page 2. Additional Information on page 2

Airdac CNE and SNE, 600/1000V, Polyethylene Sheath, SANS 1507, NRS 063 & NRS 017

FOREWORD ONE OF THE WORLD S BIGGEST COMPANIES IN THE SECTOR.

Sectionneur rotatif traversant d intérieur Wall bushing disconnector for indoor substation

BRÖCKSKES D-VIERSEN PV1-F 4,0 mm BRÖCKSKES D-VIERSEN PV1-F 4,0 mm d d 2 2 C VDE-REG.-Nr /2009

INTERNATIONAL STANDARD

ISO 9001 ISO CABLES AND WIRES CATALOGUE 2008

FIRE RESISTANT CABLES FP200 GOLD

Power and Wiring Cables

AFUMEX LSX LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 BASEC APPROVED PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:

Chemical resistance Accidental

MEDIUM VOLTAGE CABLES Up to and including 36 KV

PROFIBUS cable. for PROFIBUS-PA and -DP 10/ EN

EDS KV TRIPLEX CABLE

Gulf Cable & Electrical Ind. Co.

CB Test Certificates

Flexible cables for submersible products

Compact I/O End Caps/Terminators

PROFIBUS cable. PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications

CABLES FOR PHOTOVOLTAIC SOLAR ENERGY INSTALLATIONS FOR CLEAN ENERGY

Festoon 715 P PUR cable for flexible application in festoon systems

Flygt flexible cables

Switching Power Supply XP POWER INC. SUITE 150, 1241 E DYER RD SANTA ANA CA 92705, USA XP POWER INC SUITE 150, 1241 E DYER RD SANTA ANA CA 92705, USA

Building Cables and Wires

COAX Cables Radio Frequency Cables

Gexol. Gexol. The Global Cable Solutions Company. Designed for safe, reliable performance in the harshest oil and gas operating environments

CERTIFICATE OF COMPLIANCE

MITSUBISHI ELECTRIC JET TOWEL HAND DRYER CANNON AIR JET

COMMISSION INTERNATIONALE DE KARTING - FIA

Gulf Cable & Electrical Ind. Co.


LOW VOLTAGE POWER CABLES

Direct AC Wiring Option Installation Guide

Instrumentation Cable Power Cable Assembly Solutions...32

with coloured cores and overall copper screen UL/CSA... 17

Note concernant votre accord de souscription au service «Trusted Certificate Service» (TCS)

KNOW YOUR OPTIONS: 230 KV POWER CABLES

Fire retardant IEC

IECEE OPERATIONAL DOCUMENT

UGVCL/SP/591/11KV HT AB CABLE

DATA SHEET SERVO LK SMS FX8PLUS SIGNAL

LeI E. Henri CERVELLO

LEAD FREE FIREX. Interlock Armored Cables TECK90 and MC Industrial Cables. w w w. n e x a n s e n e r g y. c o m

Section kv Power Cables

INTERNATIONAL STANDARD

B05: Cable protection and sheathing

The Handbook 2013 EDITION

DECLARATION DE CONFORMITE Declaration of Conformity

KNOW YOUR OPTIONS: 69 KV XLPE POWER CABLE

CABLE SPECIFICATION CAN CAB RJ45-SUBD9

R.C.C.B. s two-pole LEXIC


Flexible Control Cables

3/2- and 2/2-way cartridge valve type BVE

3.6/6 kv XLPE insulated cables 5. 6/10 kv XLPE insulated cables /15 kv XLPE insulated cables /20 kv XLPE insulated cables 35

CLEVELAND CABLE LOCATIONS

Archived Content. Contenu archivé

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Tri-Rated Flexible PVC Equipment Wire

NEW GENERATION AGA-LED LIGHTING UNITS

Model 685B0011C14. Vibration Switch. Installation and Operating Manual

PCB transformers. Short circuit proof PCB transformer VB. General Data. Advantages. Applications. Circuit diagram. Standards & 1 Certifications W v

VDE-approved PVC-Control Cables

Switching Power Supply DELTA ELECTRONICS, INC. CTF Stage 2. Additional Information on page 2. E A27-CB-1 issued on

Archived Content. Contenu archivé

Comparative study for cables and busbars

INSIGHT LONG EFFECT. gerflor.com VOYEZ PLUS GRAND LOOK FURTHER

CONNECTEURS CONNECTORS. axocoax

Commercial Coaxial Cable

E-STOP relays, safety gate monitors

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

AD511 Active Iridium Antenna User Manual Mar 12 V4.0

Temperature Permissible ambient temperature. Weather Resistance to severe weather conditions. Impacts Cable mechanical resistance to impacts

RAIL /// WIRE & CABLE WHERE THE BEST IDEAS IN RAIL BEGIN

Sun Enterprise Optional Power Sequencer Installation Guide

100% EMI Emission Containment

This document is a preview generated by EVS

Series 8146/5-V37 and Series 8150/5-V37

ALUMINIUM. Conductors

Cables, Cable Laying & Accessories Manual

Quality Reliability Innovation. ISO 9001 : 2000 CERTIFIED BY AFAQ No. QUAL / 1997 / 7034 a COPPER TELECOMMUNICATION CABLES

Transcription:

CABLES UNIPOLAIRES EXTRA-SOUPLE SANS GAINE UNSHEATHED SINGLE CORE CABLES WITH EXTRA-FLEXIBLE CONDUCTOR CARACTERISTIQUES DU CABLE CABLE CHARACTERISTICS - 40 C Bon Résistant à Bon / Good Tenue au feu Zero halogène Sans plomb Good huile EN 61034 Fire behaviour Zero halogen Without lead Oil EN 60332-1 EN 50267-2 resistant EN50266-2-4 EN 60684-2 Bon / Good EN 50305 9.1 EN 50305 9.2 EN 60811 ---------- voir page 2 / see on page 2 ----------- DESCRIPTIF DU CABLE AME / CONDUCTOR âme extra souple en cuivre recuit étamé ou cuivre rouge, ronde, câblée, classe 6 CABLE DESIGN extra flexible circular tin-coated annealed copper or plain copper conductor, class 6 conforme à / according to EN 60228 température / temperature 120 C en régime permanent / in continuous duty - 250 C en court circuit / in short circuit ou /or 150 C en régime permanent / in continuous duty - 350 C en court circuit / in short circuit N.B. Pour utilisation à 150 C en régime permanent, l'âme doit être impérativement en cuivre nu recuit - Nous consulter For use at 150 C in steady operation, it is imperative that the conductor is annealed plain copper - Consult us ISOLATION / mélange silicone / silicone compound conforme à / according to EN 50382-1 (EI 112) couleur / colou r : NOIRE / BLACK Marquage / Marking (exemple / example) PRYSMIAN 255 -TEROL HT TX - EN 50382-2 3600V 185 F 120 C X N de lot / batch No. Catalogue - Indice E du 02/12/2009 1/7

NORMES D'ENVIRONNEMENT ET D'ESSAIS ENVIRONMENTAL AND TEST STANDARDS Environnement Environment TS 45545 - HL4 TS 45545 - HL4 (équivalent à NF F 16-101 - C F0, BS 6853 - la (equivalent to NF F 16-101 - C F0, BS 6853 - la & DIN 5510) & DIN 5510) Tenue au feu Fire performance essai à la flamme EN 60332-1 flame test EN 60332-1 (NF C 32-070 C2, CEI 60332-1 (NF C 32-070 C2, IEC 60332-1 & DIN VDE 0482 265-2-1) & DIN VDE 0482 265-2-1) essai au feu EN 50266-2-4 fire test EN 50266-2-4 (CEI 60332-3 & DIN VDE 0482 266-2-4) (IEC 60332-3 & DIN VDE 0482 266-2-4) + EN 50305 9-1 + EN 50305 9-1 (ex BS 4066-1 & 3, et DIN VDE 472 804 A-C) (ex BS 4066-1 & 3, et DIN VDE 472 804 A-C) Absence d'halogène Halogen free performance EN 50267-2-1 (CEI 60754-1) EN 50267-2-1 (IEC 60754-1) EN 60684-2 EN 60684-2 Corrosivité / Toxicité Corrosivity / Toxicity toxicité EN 50305 9.2 toxicity EN 50305 9.2 acidité et toxicité des gaz EN 50267-2-2 acid and toxic gases EN 50267-2-2 (CEI 60754-2) & NF X 70-100 (IEC 60754-2) & NF X 70-100 Dégagement de fumées Smoke emission faible dégagement de fumée EN 61034 low smoke EN 61034 (CEI 61034 & DIN VDE 0482 268-2) (IEC 61034 & DIN VDE 0482 268-2) C 20452 C 20452 ex BS 7622-1 & 2, et DIN VDE 472 816 ex BS 7622-1 & 2, and DIN VDE 472 816 CERTIFICATS D'HOMOLOGATION HOMOLOGATION CERTIFICATES ALSTOM SNCF RATP Catalogue - Indice E du 02/12/2009 2/7

Définition des tensions (V) Voltage definition (V) Tension Tension assignée / Assigned voltage nominale EN 61034 Nominal Courant alternatif (c.a.) Courant continu (c.c.) voltage Alternatice current (a.c.) Direct current (d.c.) (V) Uo U Um Vo V 6.000 3.600 6.000 7.200 5.400 9.000 CONDITIONS DE POSE LAYING CONDITIONS D < 12 mm r = 3 D D > 12 mm r = 4 D avec D = diamètre extérieur du câble with D = cable outer diameter Catalogue - Indice E du 02/12/2009 3/7

CARACTERISTIQUES DIMENSIONNELLES DIMENSIONAL CHARACTERISTICS Code produit Section Ø sur épaisseur Ø extérieur Code product nominale âme nominale nominale Masse d'isolation EN 61034 (1) Noir Vert/jaune Nominal Ø over Insulation Outer Mass cross conductor nominale nominal Ø Black Green/yellow section thickness (approx) (1) (approx) mm² mm mm mm kg/km PHUFX301 PHUFX501 50 8,6 3,0 15,7 ± 0,5 570 PHUFX302 PHUFX502 70 11,0 3,0 17,5 ± 0,6 770 PHUFX303 PHUFX503 95 12,5 3,0 19,0 ± 0,6 980 PHUFX304 PHUFX504 120 14,2 3,1 20,8 ± 0,7 1.200 PHUFX305 PHUFX505 150 15,8 3,1 22,3 ± 0,7 1.480 PHUFX306 PHUFX506 185 17,5 3,2 24,2 ± 0,8 1.800 (1) Toutes les épaisseurs sont conformes aux normes EN (1) All thicknesses are according to EN standards Catalogue - Indice E du 02/12/2009 4/7

CARACTERISTIQUES ELECTRIQUES ELECTRICAL CHARACTERISTICS Section Résistance Résistance Réactance Capacité Intensité Chute de Résistance Résistance nominale maxi à 20 C maxi à 120 C à 50 Hz admissible tension d'isolement d'isolement en c.c. en c.a. cos j = 0,8 mini à 20 C mini à 120 C (1) (1) (2) (3) Minimum Minimum Nominal Maxi d.c. Maxi a.c. EN 61034 Capacitance Permissible Voltage insulation insulation cross resistance resistance at 50 Hz current drop resistance resistance section at 20 C at 120 C (approx) (approx) rating cos j = 0,8 at 20 C at 120 C mm² W/km W/km W/km µf/km A V/A/km MW.km MW.km 50 0,393 0,548 0,10 0,33 336 0,86 340 3,4 70 0,277 0,386 0,09 0,36 420 0,63 300 3,0 95 0,210 0,293 0,09 0,40 504 0,50 270 2,7 120 0,164 0,229 0,08 0,43 595 0,41 250 2,5 150 0,132 0,185 0,08 0,55 685 0,34 220 2,2 185 0,108 0,152 0,08 0,57 783 0,29 210 2,1 Conditions de validité / Validity terms (1) Résistance en cuivre nu (cuivre étamé sur demande) / plain copper resistance (tinned copper on request) (2) Intensités pour 1 conducteur / Permissible current ratings for 1 core Pour câbles multiconducteurs avec 2, 3 ou 4 conducteurs chargés, il convient de multilier ces valeurs par 0,8. For multicore cables with 2, 3 or 4 loaded conductors, these values must be multiplied by 0,8. conforme à / according to EN 50343:2003 - Annexe B Ces valeurs sont applicables pour une seule liaison posée à l'air libre, à l'abri du soleil, température ambiante 45 C, température maximum à l'âme en régime de fontionnement 120 C, pour température de 150 C voir norme. These values are applicable for a single line in free air, sheltered from the sun, ambient temperature 45 C, maximum conductor temperature 120 C in continuous working, for 150 C temperature see standard. (3) Les valeurs de chute de tension approximatives mentionnées dans les tableaux sont celles d'une liaison TRIPHASE Approximate voltage drop values noticed in the table are according to a THREE PHASE CURRENT Catalogue - Indice E du 02/12/2009 5/7

CARACTERISTIQUES ELECTRIQUES ELECTRICAL CHARACTERISTICS Section nominale COURANT DE COURT-CIRCUIT DANS LES AMES A Nominal EN 61034 cross SHORT CIRCUIT CURRENT RATING IN CONDUCTORS section A mm² 0,1 s 0,2 s 0,5 s 1 s 2 s 5 s 50 19.944 14.102 8.919 6.307 4.460 2.820 70 27.921 19.743 12.487 8.829 6.243 3.949 95 37.893 26.794 16.946 11.983 8.473 5.359 120 47.865 33.845 21.406 15.136 10.703 6.769 150 59.831 42.307 26.757 18.920 13.379 8.461 185 73.791 52.178 33.001 23.335 16.500 10.436 Conditions de validité / Validity terms température initiale / initial temperature = 120 C température finale / final temperature = 250 C selon / according to IEC 60949 Catalogue - Indice E du 02/12/2009 6/7

FACTEURS DE CORRECTION CORRECTION FACTORS FACTEURS DE CORRECTION Température EN 61034 POUR S AMBIANTES DIFFERENTES DE 45 C Temperature CORRECTION FACTORS FOR AMBIENT OTHERS THAN 45 C C A 35 1,06 45 1,00 55 0,93 65 0,86 75 0,77 85 0,68 95 0,58 105 0,45 115 0,26 selon / according to EN 50343:2003 - Annexe D Catalogue - Indice E du 02/12/2009 7/7