INSTRUCTION BOOKLET. AQ SAS Standard Arc Schemes. AQ 100 Series



Similar documents
New standardized approach to arc flash protection

Medium voltage arc flash eliminator units VAM 3ED,

Arc Terminator Active Arc-Resistant Switchgear

Arc Protection Relay REA 101. Operator s Manual

Feeder protection. for overhead lines and cables in isolated neutral or compensated networks. Specification

How To Choose A Transformer

Inverter / Charger Installation General Operations and AC and DC Connections

Relion. Power system protection and automation reference Extending substation life cycle with IEC 61850

The Application of Circuit Breakers to Reduce Downtime in Datacentres

INSTRUCTION BOOKLET. AQtivate Pro. Substation Management Software

Mitigation of Arc-Flash Hazards and Reduction of Costs by Selective Arc-Flash Protection

EVALUATION OF ALTERNATIVE BACKUP PROTECTION SCHEMES ON A 66KV DISTRIBUTION NETWORK

What will MV switchgear look like in the future? by Jean-Marc Biasse

Feeder Protection Relay. Technical Reference Manual - ANSI Version

ISIO 200. Binary Input/Output (I/O) Terminal with IEC Interface

Permissible ambient temperature Operation Storage, transport

GE Protection and Control Business Department. Page 1 Date 5/11/99

21 st Century Facilities

Suitable for Emergency, Peak and Prime Power System Applications. Low Voltage Automatic Transfer Switch Systems

Electrical Shore Connections / Cold Ironing

Controller Automation, Model II+

Test & Data Management Software

ZONE SELECTIVE INTERLOCKING (ZSI) APPLICATION AND TESTING GUIDE SIEMENS WL UL489 AND UL1066 AIR CIRCUIT BREAKERS

FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid

Application of Four-Pole Circuit Breakers within Data Centers

SPECIAL TOPICS ON GROUND FAULT PROTECTION AND PROTECTION COORDINATION IN INDUSTRIAL AND COMMERCIAL POWER SYSTEMS

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Switchboards. Basis of Design. Design Evaluation

UFES Active protection for switchgear

Chapter 1. Network Structures

Numerical Differential Protection

OPTIMIZING POWER SYSTEM PROTECTION FOR MODERN DATA CENTERS

SpotCell Automatic Dialer System

Choosing for tranquility

Arc Flash Energy Mitigation Techniques

Medium Voltage Products. ZN1 12 kv arc-proof air-insulated switchgear for primary distribution

TDMS Test & Data Management Software

Low Voltage Switchgear

Teleprotection Schemes and Equipment. James W. Ebrecht Young Power Equipment Scottsdale, AZ

SCADA Controlled Multi-Step Automatic Controlled Capacitor Banks & Filter Banks

Paralleling Switchgear

New Supervisory Control and Data Acquisition (SCADA) Based Fault Isolation System for Low Voltage Distribution Systems

White Paper - July ATS021-ATS022 Automatic transfer switching

Relion. Power system protection and automation reference Fast substation busbar protection with IEC and GOOSE

Unified requirements for systems with voltages above 1 kv up to 15 kv

Part 1 System Modeling & Studies for Existing Systems

Medium voltage products UniSec for Smart Grid Air-insulated medium-voltage secondary distribution switchgear

Eaton Safety & Reliability Solutions in the Oil & Gas Industry Electrical

Electric utilities may vary in their application of end-to-end testing

SWITCHGEAR Section 16. SECTION INCLUDES This Section includes service and distribution switchboards rated 600 V and less.

Current Limiting Protector For Systems rated kV and continuous currents through 5000A.

Arc Flash Mitigation & Selective Co-ordination

7. Reactive energy compensation

Eaton s Electrical Services & Systems. Technical Training Safety Training

Siemens AG Fieldbus solutions with the SIMATIC PCS 7 distributed control system. Brochure April 2010 SIMATIC PCS 7. Answers for industry.

ISBN

Catalog. Arc Guard System TM TVOC-2

Manual for Fire Suppression & Methane Detection System

EMR-3000 Modbus Register Maps

TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY

SF 6 Gas Insulated Switchgear Type SDF for 170 kv

..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark...

Relion 611 series. Feeder Protection and Control REF611 Application Manual

Transmission Protection Overview

Relion 605 series. Feeder protection and control / Feeder protection REF601 / REJ601 Product Guide

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

Atlas Copco Generators QIX QAS QAC USER MANUAL FOR THE. Qc4001 GENERATOR CONTROLLER

REA 101 Arc protection relay. Operator s manual

Electrical Network Management System

INTERNATIONAL POWER DISTRIBUTION CONGRESS CIDEL ARGENTINA 2002

For a phase-to-phase voltage between 100 V and 1000 V. The standard ratings are: 400 V V V (at 50 Hz)

INTREPID Perimeter Intrusion Detection System

Perimeter Security System

Earth Fault Detection Basics in Theory

Voltage Regulator SPAU 341 C. Product Guide

Digital Expansion Modules Specifications

The Intelligent AX1 Switchgear for Medium Voltage

NFPA 70E 2012 Rolls Out New Electrical Safety Requirements Affecting Data Centers

AORC Technical meeting 2014

Safety By Design. Strategies for Electrical Contractors

Franco Vecchiato, SAM LPBS Regional Manager New SACE Emax 2 From Circuit-breaker to Power Manager

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

Critical-Power Automatic Transfer Systems Design and Application

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Electric Power Distribution

Reyrolle Protection Devices. 7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for energy

QUESTIONS and ANSWERS RFB , Metal Clad Switchgear and Power Control Room

Local Back-up Protection for an Electric Power System

Remote Monitoring and REC 501 Control Unit Product Guide

RISK MITIGATION for ELECTRICAL WORK. Feb 2013 San Diego CA

ESP 120 M1, ESP 208 M1, ESP 240 M1, ESP 415 M1, ESP 277 M1, ESP 480 M1 and M1R variants. Installation instructions ESP M1/M1R mains protectors

SIPROTEC Protection Technology

Power Generator Switching for Power Engineers Inc. with. Distrix Software Defined Infrastructure. A Distrix Networks Case Study.

Relion 605 series. Self-powered feeder protection REJ603 Product Guide

Contact Center CC-165 INSTALLATION & USER'S GUIDE

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

Integration of Distributed Generation in the Power System. IEEE Press Series on Power Engineering

ECE 586b Course Project Report. Auto-Reclosing

Data Bulletin. Circuit Breaker Characteristic Trip Curves and Coordination Class 0600 TRIP CURVES AND COORDINATION CIRCUIT BREAKER TRIP CURVES

Secure your electrical network. PACiS The Safety Solution for Healthcare Institutions

Switchgear Application Issues for Mission Critical Power Systems, Part One

Transcription:

INSTRUCTION BOOKLET AQ SAS Standard Arc Schemes AQ 100 Series

Instruction booklet Standard arc schemes for AQ 100 series 2 (28) Revision 1.2 Date August 2011 Changes - Add trade mark to SAS. - AQ SAS scheme 0A is added into this booklet. - The dipswitches texts of AQ 110P and AQ101 are updated. - All named as incoming feeder 1 are changed to incoming feeder A. All named as incoming feeder 2 are changed to incoming feeder B. - The AQ101 dipswitch SW1-2 (Fast/CBFP) is changed to turn ON and set as Fast mode in all schemes. The AQ110P dipswitch SW1-8 (S1: L>/L>+I>) is changed to turn ON and set as only light mode in scheme IA1, IB1, IIA1 and IIB1. - In scheme IB1 and IIB1 figures, HSO1 is in parallel with T1 to trip the main breaker CB1. The text (HSO1/T1) is changed to HSO1+T1. - In the AQ101 signals description of scheme IB1 and IIB1, BI1 is changed to NOT IN USE. - The amount of outgoing feeders of scheme IIB1 is changed to 4 feeders. This booklet describes only the Standard Arc Schemes (AQ-SAS ) for AQ 100 series arc protection system. It is important to read through instruction manuals of AQ 100 series units before applying the system.

Instruction booklet Standard arc schemes for AQ 100 series 3 (28) TABLE OF CONTENTS 1. STANDARD ARC SCHEMES (AQ SAS )... 4 1.1 Scheme AQ 0A (One Main)... 5 1.1.1 Scheme characteristics... 5 1.1.2 I/O description... 6 1.1.3 Trip logic, connection diagram and dipswitch settings... 7 1.2 Scheme AQ IA1 (One Main)... 8 1.2.1 Scheme characteristics... 8 1.2.2 I/O description... 9 1.2.3 Trip logic, connection diagram and dipswitch settings... 10 1.3 Scheme AQ Ib1 (One Main)... 12 1.3.1 Scheme characteristics... 12 1.3.2 I/O description... 13 1.3.3 Trip logic, connection diagram and dipswitch settings... 14 1.4 Scheme AQ- IIa1 (Main-Tie-Main)... 16 1.4.1 Scheme characteristics... 16 1.4.2 I/O description... 17 1.4.3 Trip logic, connection diagram and dipswitch settings... 20 1.5 Scheme AQ-IIB1 (Main-Tie-Main)... 22 1.5.1 Scheme characteristics... 22 1.5.2 I/O description... 23 1.5.3 Trip logic, connection diagram and dipswitch settings... 26 2. REFERENCE INFORMATION... 28

Instruction booklet Standard arc schemes for AQ 100 series 4 (28) 1. STANDARD ARC SCHEMES (AQ SAS ) AQ SAS is a fully tested and documented preconfigured arc protection solution library. The AQ SAS approach save engineering time even in the most complex applications and secure effective commissioning of the AQ 100 arc protection system. To apply the AQ SAS the wiring and dipswitch settings of the applied scheme shall be implemented as described in this chapter. The amount of outgoing feeders does not impact the settings but only the quantity of the units applied. The amount of arc sensors per Zone may vary and does not impact the settings. Therefore the schemes may be extended or reduced by adding or removing units with identical settings and wiring. Different amount or type of arc sensors per Zone may be utilized as well. Also the protected Zones may be reduced by simply not connecting the sensors and/or trip signals of respective protected Zone(s). In all schemes there are a set of user selectable parameters such as current measurement nominal values, enable/disable the CBFP function and choose the trip criteria, i.e. trip on arc light only or simultaneous arc light and overcurrent condition. The AQ 100 series is applicable for other type of schemes as well. If your particular application is not included in AQ SAS library consult your nearest Arcteq representative for a solution.

Instruction booklet Standard arc schemes for AQ 100 series 5 (28) 1.1 SCHEME AQ 0A (ONE MAIN) 1.1.1 SCHEME CHARACTERISTICS Number of incoming feeders 1 Number of tie breakers 0 Selective trip of feeder circuit breaker No Master trip function No Units applied AQ 110P Figure 1-1: Scheme 0A single-line diagram

Instruction booklet Standard arc schemes for AQ 100 series 6 (28) 1.1.2 I/O DESCRIPTION AQ 110P : I/O Function IL1,IL2,IL3 Monitoring of phase overcurrent threshold level at incoming feeder 1 Io Monitoring of residual current threshold level at incoming feeder 1 S1 Monitoring of arc light in incoming feeder 1 cable compartment and bus-duct (Zone 1) S2, S5 Monitoring of arc light in incoming feeder 1 breaker compartment and incoming feeder busbar compartment. (*) S3, S4 Monitoring of arc light in outgoing feeder breaker compartments and busbars compartment (Zone 2) (*) T1 Trip of incoming main circuit breaker CB1 in case of fault in Zones 1 and 2 and in case of FAST trip of CB4-x. T2 Trip of upstream circuit breaker CB2 in case of fault in Zone 1 and in case of FAST trip of CB1 T3 Trip of outgoing feeder circuit breaker CB4-x in case of fault in Zone 2. T4 Trip of outgoing feeder circuit breaker CB4-x in case of fault in Zone 2. SF System failure dry contact for alarming *FAST dipswitch (SW2-4) can be set to ON position in order to activate the FAST function on T2 and T3.

Instruction booklet Standard arc schemes for AQ 100 series 7 (28) 1.1.3 TRIP LOGIC, CONNECTION DIAGRAM AND DIPSWITCH SETTINGS CB1 CB2 CB4-x Zone 1 x x x Zone 2 x x x Zone 3 x x x AQ 110 T1 T2 T3,T4 Table 1-1: Scheme 0A trip logic Figure 1-2: Scheme IA1 system connection diagram and dipswitch settings

Instruction booklet Standard arc schemes for AQ 100 series 8 (28) 1.2 SCHEME AQ IA1 (ONE MAIN) 1.2.1 SCHEME CHARACTERISTICS Number of incoming feeders 1 Number of tie breakers 0 Selective trip of feeder circuit breaker Yes Master trip function Yes Units applied AQ 110P and AQ 101 Figure 1-3: Scheme IA1 single-line diagram

Instruction booklet Standard arc schemes for AQ 100 series 9 (28) 1.2.2 I/O DESCRIPTION AQ 110P: I/O IL1,IL2,IL3 Io S1 Function Monitoring of phase overcurrent threshold level at incoming feeder A Monitoring of residual current threshold level at incoming feeder A Monitoring of arc light in incoming feeder A cable compartment and bus-duct (Zone 1) S2, S3 Monitoring of arc light in incoming feeder A breaker compartment and incoming feeder busbar compartment (Zone 2)* HSO1 HSO2 BO1 BI1 BI2 Sending overcurrent information to AQ101 units Sending master trip information to AQ101 units Receiving light information from AQ 101 units of busbar T1 Trip of incoming main circuit breaker CB1 in case of fault in Zones 1 and 2 and in case of CBFP(**) of CB4-x. T2 Trip of upstream circuit breaker CB2 in case of fault in Zone 1 and in case of CBFP(**) of CB1 T3 T4 SF Trip alarm (if in use) System failure dry contact for alarming *Sensor channels S4 and S5 may be utilized if more sensors are required in Zone 2. **CBFP dipswitch (SW2-4) must be set to ON position in order to activate the CBFP function.

Instruction booklet Standard arc schemes for AQ 100 series 10 (28) AQ101 (all units): I/O S1 S2 BO1 BI1 BI2 T1 T2 T3 T4 Function Monitoring of arc light in outgoing feeder cable compartment for selective trip (Zone 3) Monitoring of arc light in outgoing feeder breaker compartment and busbar compartment (Zone 2) (*) Sending light information to AQ 110 unit of incoming feeder A Receiving overcurrent information from AQ 110 unit of incoming feeder A Receiving master trip information from AQ 110 unit of incoming feeder A Trip of outgoing feeder circuit breaker CB4-x in case of activation of S1 and BI1. Also performing master trip in case of fault in Zone 2. SF System failure dry contact for alarming *Sensor channels S3, S4 and S5 may be utilized if more sensors are required in Zone 2. 1.2.3 TRIP LOGIC, CONNECTION DIAGRAM AND DIPSWITCH SETTINGS Zone 1 x x CB1 CB2 CB4-x Zone 2 x x(mt) Zone 3 CBFP of CB1 x CBFP of CB4-x x AQ 110 T1 T2 AQ 101-x Table 1-2: Scheme IA1 trip logic x T1

Instruction booklet Standard arc schemes for AQ 100 series 11 (28) Figure 1-4: Scheme IA1 system connection diagram and dipswitch settings

Instruction booklet Standard arc schemes for AQ 100 series 12 (28) 1.3 SCHEME AQ IB1 (ONE MAIN) 1.3.1 SCHEME CHARACTERISTICS Number of incoming feeders 1 Number of tie breakers 0 Selective tripping of feeder circuit breaker No Master trip function Yes Units applied AQ 110P and AQ 101 Figure 1-5: Scheme IB1 single-line diagram

Instruction booklet Standard arc schemes for AQ 100 series 13 (28) 1.3.2 I/O DESCRIPTION AQ110P : I/O IL1,IL2,IL3 Function Monitoring of phase overcurrent threshold level at incoming feeder A Io S1 Monitoring of residual current threshold level at incoming feeder A Monitoring of arc light in incoming feeder A cable compartment and bus-duct (Zone 1) S2, S3 Monitoring of arc light in incoming feeder A breaker compartment and incoming feeder busbar compartment (Zone 2)* HSO1 HSO2 BO1 BI1 BI2 T1 Trip of incoming main circuit breaker CB1 in parallel with T1 Sending master trip information to AQ101 units Receiving light information from AQ 101 units of busbar Trip of incoming main circuit breaker CB1 in case of fault in Zones 1 and 2 T2 Trip of upstream circuit breaker CB2 in case of fault in Zone 1 and in case of CBFP(**) of CB1 T3 T4 SF Trip alarm (if in use) System failure dry contact for alarming *Sensor channels S4 and S5 may be utilized if more sensors are required in Zone 2. **CBFP dipswitch (SW2-4) must be set to ON position in order to activate the CBFP function.

Instruction booklet Standard arc schemes for AQ 100 series 14 (28) AQ101: I/O Function S1 (*) S2,S3,S4 Monitoring of arc light in outgoing feeder breaker compartments and busbars compartment (Zone 2) (*) BO1 Sending light information to AQ 110 unit of incoming feeder A BI1 BI2 Receiving master trip information from AQ 110 unit of incoming feeder A T1 Master trip to CB4-x in case of fault in Zone 2. T2 Master trip to CB4-x in case of fault in Zone 2 T3 Master trip to CB4-x in case of fault in Zone 2 T4 (**) SF System failure dry contact for alarming *Sensor channel S1 may be applied if more sensors are needed in Zone 2. For more information refer to AQ 101 Arc protection unit instruction manual. Sensor channel S5 may be applied as well. **T4 may be applied in case of more CB s 1.3.3 TRIP LOGIC, CONNECTION DIAGRAM AND DIPSWITCH SETTINGS CB1 CB2 CB4-x Zone 1 x x Zone 2 x x(mt) CBFP of CB1 x AQ 110 T1,HSO1 T2 AQ 101-x * Tx indicates T1, T2 and T3 of AQ101. Tx(*) Table 1-3: Scheme IB1 trip logic

Instruction booklet Standard arc schemes for AQ 100 series 15 (28) Figure 1-6: Scheme IB1 system connection diagram and dipswitch settings

Instruction booklet Standard arc schemes for AQ 100 series 16 (28) 1.4 SCHEME AQ- IIA1 (MAIN-TIE-MAIN) 1.4.1 SCHEME CHARACTERISTICS Number of incoming feeders 2 Number of tie breakers 1 Selective trip of feeder circuit breaker Yes Master trip function Yes Units applied AQ 110P and AQ 101 Figure 1-7: Scheme IIA1 single-line diagram.

Instruction booklet Standard arc schemes for AQ 100 series 17 (28) 1.4.2 I/O DESCRIPTION AQ110P (Busbar A): I/O Function IL1,IL2,IL3 Monitoring of phase overcurrent threshold level at incoming feeder A Io Monitoring of residual current threshold level at incoming feeder A S1 Monitoring of arc light in incoming feeder A cable compartment and bus-duct (Zone 1A) S2, S3 Monitoring of arc light in incoming feeder A breaker compartment and incoming feeder busbar compartment (Zone 2A)* HSO1 Sending overcurrent information to AQ101 units at busbar A HSO2 Sending master trip information to AQ101 units at busbar A BO1 Sending overcurrent information to AQ 110 unit at incoming feeder 1B BI1 Receiving overcurrent information from AQ 110 unit at incoming feeder 1B BI2 Receiving light information from AQ 101 units of busbar A T1 Trip of incoming main circuit breaker CB1A in case of fault in Zones 1A and 2A and in case of CBFP(**) of CB4A-x or CBFP(**) of circuit breaker CB3AB. T2 Trip of upstream circuit breaker CB2A in case of fault in Zone 1A and in case of CBFP(**) of CB1A T3 Trip of tie breaker CB3AB in case of fault in Zone 2A and CBFB(**) of CB4A-x T4 Trip alarm (if in use) SF System failure dry contact for alarming *Sensor channels S4 and S5 may be utilized if more sensors are required in Zone 2A. **CBFP dipswitch must be set to ON position in order to activate the CBFP function.

Instruction booklet Standard arc schemes for AQ 100 series 18 (28) AQ110P (Busbar B): I/O Function IL1,IL2,IL3 Monitoring of phase overcurrent threshold level at incoming feeder B Io Monitoring of residual current threshold level at incoming feeder B S1 Monitoring of arc light in incoming feeder B cable compartment and bus-duct (Zone 1B) S2, S3 Monitoring of arc light in incoming feeder B breaker compartment and incoming feeder busbar compartment (Zone 2B) (*) HSO1 Sending overcurrent information to AQ101 units at busbar B HSO2 Sending master trip information to AQ101 units at busbar B BO1 Sending overcurrent information to AQ 110 unit at incoming feeder A BI1 Receiving overcurrent information from AQ 110 unit at incoming feeder A BI2 Receiving light information from AQ 101 units of busbar B T1 Trip of incoming main circuit breaker CB1B in case of fault in Zones 1B and 2B and in case of CBFP(**) CB4B-x or CBFP(**) of circuit breaker CB3AB. T2 Trip of upstream circuit breaker CB2B in case of fault in Zone 1B and in case of CBFP(**) of CB1B T3 Trip of tie breaker CB3AB in case of fault in Zone 2B and CBFB(**) of CB4B-x T4 Trip alarm (if in use) SF System failure dry contact for alarming *Sensor channels S4 and S5 may be utilized if more sensors are required in Zone 2B. **CBFP dipswitch must be set to ON position in order to activate the CBFP function.

Instruction booklet Standard arc schemes for AQ 100 series 19 (28) AQ101 (all units at busbar A): I/O Function S1 Monitoring of arc light in outgoing feeder cable compartment for selective trip (Zone 3A) S2 Monitoring of arc light in outgoing feeder breaker compartment and busbar compartment (Zone 2A) (*) BO1 Sending light information to AQ 110 unit of incoming feeder A BI1 Receiving overcurrent information from AQ 110 unit of incoming feeder A BI2 Receiving master trip information from AQ 110 unit of incoming feeder A T1 Trip of outgoing feeder circuit breaker CB4A-x in case of activation of S1 and BI1. Also performing master trip in case of fault in Zone 2A. T2 T3 T4 SF System failure dry contact for alarming *Sensor channels S3, S4 and S5 may be utilized if more sensors are required in Zone 2A.

Instruction booklet Standard arc schemes for AQ 100 series 20 (28) AQ101 (all units at busbar B): I/O Function S1 Monitoring of arc light in outgoing feeder cable compartment for selective tripping (Zone 3B) S2 Monitoring of arc light in outgoing feeder breaker compartment and busbar compartment (Zone 2B)(*) BO1 Sending light information to AQ 110 unit of incoming feeder B BI1 Receiving overcurrent information from AQ 110 unit of incoming feeder B BI2 Receiving master trip information from AQ 110 unit of incoming feeder B T1 Trip of outgoing feeder circuit breaker CB4B-x in case of activation of S1 and BI. Also performing master trip in case of fault in Zone 2B. T2 T3 T4 SF System failure dry contact for alarming *Sensor channels S3, S4 and S5 may be utilized if more sensors are required in Zone 2B. 1.4.3 TRIP LOGIC, CONNECTION DIAGRAM AND DIPSWITCH SETTINGS CB1A CB2A CB4A-x CB3AB CB1B CB2B CB4B-x Zone 1A x x Zone 2A x x (MT) x Zone 3A x Zone 1B x x Zone 2B x x x (MT) Zone 3B x CBFP of CB1A x CBFP of CB4A-x x x CBFP of CB3AB x x CBFP of CB1B x CBFP of CB4B-x x x AQ 110A T1 T2 T3 AQ 101A-x T1 AQ 110B T3 T1 T2 AQ 101B-x T1 Table 1-4: Scheme IIA1 trip logic

Instruction booklet Standard arc schemes for AQ 100 series 21 (28) Figure 1-8: Scheme IIA1 system connection diagram and dipswitch settings.

Instruction booklet Standard arc schemes for AQ 100 series 22 (28) 1.5 SCHEME AQ-IIB1 (MAIN-TIE-MAIN) 1.5.1 SCHEME CHARACTERISTICS Number of incoming feeders 2 Number of tie breakers 1 Selective trip of feeder circuit breaker No Master trip function Yes Units applied AQ 110P and AQ 101 Figure 1-9: Scheme IIB1 single line diagram.

Instruction booklet Standard arc schemes for AQ 100 series 23 (28) 1.5.2 I/O DESCRIPTION AQ110P (Busbar A): I/O Function IL1,IL2,IL3 Monitoring of phase overcurrent threshold level at incoming feeder A Io Monitoring of residual current threshold level at incoming feeder A S1 Monitoring of arc light in incoming feeder A cable compartment and bus-duct (Zone 1A) S2, S3 Monitoring of arc light in incoming feeder A breaker compartment and incoming feeder busbar compartment (Zone 2A)* HSO1 Trip of incoming main circuit breaker CB1A in parallel with T1. HSO2 Sending master trip information to AQ101 unit at busbar A BO1 Sending overcurrent information to AQ 110 unit at incoming feeder B BI1 Receiving overcurrent information from AQ 110 unit at incoming feeder B BI2 Receiving light information from AQ 101 unit of busbar A T1 Trip of incoming main circuit breaker CB1A in case of fault in Zones 1A and 2A and in case of CBFP (**) of circuit breaker CB3AB. T2 Trip of upstream circuit breaker CB2A in case of fault in Zone 1A and in case of CBFP(**) of CB1A T3 Trip of tie breaker CB3AB in case of fault in Zone 2A T4 Trip alarm (if in use) SF System failure dry contact for alarming *Sensor channels S4 and S5 may be utilized if more sensors are required in Zone 2A. **CBFP dipswitch (SW2-4) must be set to ON position in order to activate the CBFP function.

Instruction booklet Standard arc schemes for AQ 100 series 24 (28) AQ110P (Busbar B): I/O Function IL1,IL2,IL3 Monitoring of phase overcurrent threshold level at incoming feeder B Io Monitoring of residual current threshold level at incoming feeder B S1 Monitoring of arc light in incoming feeder B cable compartment and bus-duct (Zone 1B) S2, S3 Monitoring of arc light in incoming feeder B breaker compartment and incoming feeder busbar compartment (Zone 2B) (*) HSO1 Trip of incoming main circuit breaker CB1B in parallel with T1. HSO2 Sending master trip information to AQ101 units at busbar B BO1 Sending overcurrent information to AQ 110 unit at incoming feeder A BI1 Receiving overcurrent information from AQ 110 unit at incoming feeder A BI2 Receiving light information from AQ 101 units of busbar B T1 Trip of incoming main circuit breaker CB1B in case of fault in Zones 1B and 2B and in case of CBFP(**) of circuit breaker CB3AB. T2 Trip of upstream circuit breaker CB2B in case of fault in Zone 1B and in case of CBFP(**) of CB1B T3 Trip of tie breaker CB3AB in case of fault in Zone 2B T4 Trip alarm (if in use) SF System failure dry contact for alarming *Sensor channels S4 and S5 may be utilized if more sensors are required in Zone 2B. **CBFP dipswitch (SW2-4) must be set to ON position in order to activate the CBFP function.

Instruction booklet Standard arc schemes for AQ 100 series 25 (28) AQ101 (Busbar A): I/O Function S1 (*) S2,S3,S4 Monitoring of arc light in outgoing feeder breaker compartments and busbar compartments (Zone 2A) BO1 Sending light information to AQ 110 unit of incoming feeder A BI1 BI2 Receiving master trip information from AQ 110 unit of incoming feeder A T1 Master trip to CB4A-x in case of fault in Zone 2A T2 Master trip of CB4A-x in case of fault in Zone 2A T3 Master trip of CB4A-x in case of fault in Zone 2A T4 Master trip of CB4A-x in case of fault in Zone 2A SF System failure dry contact for alarming *Sensor channel S1 may be applied if more sensors are needed in Zone 2A. For more information refer to AQ 101 Arc protection unit instruction manual. Sensor channel S5 may be applied as well.

Instruction booklet Standard arc schemes for AQ 100 series 26 (28) AQ101 (Busbar B): I/O Function S1 (*) S2,S3,S4 Monitoring of arc light in outgoing feeder breaker compartments and busbar compartments (Zone 2B) BO1 Sending light information to AQ 110 unit of incoming feeder B BI1 BI2 Receiving master trip information from AQ 110 unit of incoming feeder B T1 Master trip of CB4B-x in case of fault in Zone 2B T2 Master trip of CB4B-x in case of fault in Zone 2B T3 Master trip of CB4B-x in case of fault in Zone 2B T4 Master trip of CB4B-x in case of fault in Zone 2B SF System failure dry contact for alarming *Sensor channel S1 may be applied if more sensors are needed in Zone 2A. For more information refer to AQ 101 Arc protection unit instruction manual. Sensor channel S5 may be applied as well. 1.5.3 TRIP LOGIC, CONNECTION DIAGRAM AND DIPSWITCH SETTINGS CB1A CB2A CB4A-x CB3AB CB1B CB2B CB4B-x Zone 1A x x Zone 2A x x (MT) x Zone 1B x x Zone 2B x x x (MT) CBFP of CB1A x CBFP of CB3AB x x CBFP of CB1B x AQ 110A T1,HSO1 T2 T3 AQ 101A-x T1,T2,T3 AQ 110B T3 T1,HSO1 T2 AQ 101B-x T1,T2,T3 Table 1-5: Scheme IIB1 trip logic

Instruction booklet Standard arc schemes for AQ 100 series 27 (28) Figure 1-10: Scheme IIB1 system connection diagram and dipswitch settings.

Instruction booklet Standard arc schemes for AQ 100 series 28 (28) 2. REFERENCE INFORMATION Manufacturer information: Arcteq Relays Ltd. Finland Visiting and postal address: Wolffintie 36 F 11 65200 Vaasa, Finland Contacts: Phone: +358 10 3221 370 Fax: +358 10 3221 389 url: www.arcteq.fi email sales: sales@arcteq.fi email technical support: support@arcteq.fi