Electrical Network Management System

Size: px
Start display at page:

Download "Electrical Network Management System"

Transcription

1 Electrical Network Management System

2 Optimisation of the electrical network Measure to understand Understand to control Control to optimise Cost of power and fluids Power quality Power availability 2

3 Improvement process Collect measurement data Organise measurement data Devices Communication Software Check Implement Solutions Design / Solutions Analysis Improve the distribution system 3

4 Optimisation of the electrical network : costs Monitor load curves Reduce energy cost Monitor load curve -> implement load-shedding schemes -> concentrate heavy consumptio during off-peak times -> avoid exceeding stipulated limits Monitor power factor -> implement reactive compensation schemes Optimize utility contract & avoid penalties 4

5 Optimisation of the electrical network : costs Reduce energy cost Sub-metering / cost allocation -> allocate internal cost -> implement awareness program (best practices, peak shaving) Multi-sites aggregation to negotiate better rates Allocate energy costs 5

6 Optimisation of the electrical network : costs Optimize investment Identify spare capacity through analyze of Energy usage Optimize safety margin between installed Power and demand Power -> avoid unnecessary investme when modifications or extensions are required Extend equipment life time & reduce losses through Power quality improvement (cables, transformers, capacitors, moto electronics...) Analyse energy usage 6

7 Optimisation of the electrical network : quality Monitor Power Factor / Reactive Energy Harmonics Neutral Current due to addition of H3, 6, 9... & Current unbalance Voltage or Current unbalance Frequency on Diesel Generator Voltage sags & swells due to load fluctuation (motor starting ), power up of transformer or capacitor banks, lightning... Transients Monitor THD 7

8 Optimisation of the electrical network : quality To avoid Increased losses in cables & transformers Equipment destruction or reduced life time due to overheating (transformers, capacitors, motors VSD s, neutral cables ) & vibrations (motors) Untimely CB tripping Process disturbance (sensitive equipment: relays, VSD PLC s, motor speed instability...) Perturbation of communications Monitor currents & voltages & to check energy supply complianc 8

9 Optimisation of the electrical network : availability Help for preventative maintenance -> detect problem early -> avoid shut down -> minimize production losses Alarm on key parameters & record events Alarming on key parameters Number of CB O/C operations CB contact wear Identify polluting loads (high level of Harmonics) & pull them apart from sensitive loads, install filters or even chang them Balance bus-bars after demand Power analysis 9

10 Optimisation of the electrical network : availability Help for corrective maintenance -> minimize down time -> minimize production losses Look at Sequence of Events Recording, Waveform captures Identify origin of problems : - internal cause - or problem coming from Utility Check Voltage disturbances, overloads... Detect voltage disturbances 1 0

11 Architecture Software SMS Web browser Ethernet Communication interface EGX - ECC card of the CM3000 or 4000 RS485 ModBUS local network Communicating devices Power Meters Circuit Monitors Circuit-breakers Protection devices 1 1

12 Ex. 1: intelligent devices distributed in the network, without communications MV switchboard MSB MV protection and monitoring using Sepam Measurement using PM650 Protection and monitoring of LV incomers using Masterpact NW Measurement on outgoers using PM

13 Ex. 2: several devices with a local power management software PMX or SMS 1500 depending on needs RS485 Modbus MV/LV substation 1 MV/LV substation 2 1 3

14 Ex. 3: remote management via Ethernet SMS 1500 Information Manager reports Internet Explorer Ethernet Modbus TCP/IP Modbus RS485 Real time data EGX400 gateway MV/LV substation 1 MV/LV substation 2 1 4

15 Ex. 4: communication with BMS or SCADA SMS 1500 Internet Explorer BMS or SCADA Ethernet Modbus TCP/IP EGX gateway Modbus RS485 MV/LV substation 1 MV/LV substation 2 1 5

16 Advantages Solution oriented system preconfigured software perfect integration in the Schneider offer Concept open communication Architecture upgradeable on site software updating 1 6

17 A tool for multi-users Engineering trends logs Maintenance alarms measurements Accounting cost control optimisation 1 7

18 The range Web browser Sepam Micrologic EGX gateway SMS software CM 3000 CM 4000 PM 500 PM 800 Acquire - Measure CM 3/ ECC card Convert Use 1 8

19 Power Meters Functionality CM3000 CM4000 Apply to Critical Power Extensive Power Quality PM500 Apply to Feeders Power Metering Sub-metering / cost allocation THD monitoring PM800 Apply to Mains and Feeders Comprehensive Power Metering Basic Power Quality (harmonics analysis) Onboard data logging Waveform Capture Apply to Mains and Key Feeders Advanced Power Monitoring Power Quality with disturbance detection Onboard data logging Disturbance Waveform capture Transient Detection (CM4-T) Wave shape fault recording Variety of I/O options Highest revenue accuracy GPS time synchronization 1 9

20 Sepam Sepam Sepam 2000 MV protection unit Protection for all applications (sub-station, transformer, motor, bus-bar) All functions integrated in a single device, combined with a circuit-breaker MV monitoring and control Basic or advanced measurements Circuit-breaker status (open, closed, tripped) Remote control (open, closed commands) Trip settings, relay status Information concerning tripping causes, event log Communication protocol Modbus 2 0

21 Masterpact NT, NW Compact NS A LV circuit-breakers Protection of LV circuits using the Micrologic control unit Compact NS Masterpact NW LV monitoring and control Basic and advanced measurements Circuit-breaker status (open, closed, tripped) Remote control (open, closed commands) Trip settings, load in percent Information concerning the causes of tripping Micrologic Control unit Communication protocol Modbus BatiBus 2 1

22 PowerLogic EGX200 and EGX400 SMS Ethernet Modbus / TCP Modbus - RS485 Internet Explorer Modbus/Ethernet Gateways Protocol converter from RS485 - Modbus to Ethernet - Modbus TCP/IP 100Mbits/second 2 RS485 serial ports 2-wire and 4-wire compatibility Set up via a web browser EGX400 = EGX200 + Web page server (+ tool for easy personalisation of html pages) Fibre optic Ethernet connection 2 2

23 Ethernet Communication Card - ECC21 3 Main functions Provides a fast access to Ethernet networks to the CM3000 Share information through intranet Provides an Ethernet gateway to products daisy chained to the ECC Provides access to Power Meters, CM2000, Micrologic, Sepam, and other Modbus devices Provides an embedded HTML page server Share information with a standard Web navigator Same Ethernet card as used in CM

24 PowerLogic SMS range Architecture Client / server SMS 3000 Standalone n devices PMX 1500 SMS 1500 graphical option GFX Standalone 1 device SMS 121 Functions Measurement concentration Analysis Multidevice synthesis Device configuration Advanced analysis Meters Bar graphs Custom tables Advanced functions - automatic tasks - custom reports 2 4

25 Application : Remote monitoring and Alarm (1) 2 5

26 Application : System Monitoring and Alarm (2) 2 6

27 Application : Fault Analysis (1) 2 7

28 Application : Fault Analysis (2) 0.5 cycle 2300A / ms 2 8

29 Application : Power Quality Monitoring (Harmonic) 2 9

30 Application : Energy Management (Historical Information) /15/02 12:31:00 PM 10/15/02 8:51:00 PM 10/16/02 5:11:00 AM 10/16/02 1:31:00 PM 10/16/02 9:51:00 PM 10/17/02 6:11:00 AM 10/17/02 2:31:00 PM 10/17/02 10:51:00 PM 10/18/02 7:11:00 AM 10/18/02 3:31:00 PM 10/18/02 11:51:00 PM 10/19/02 8:11:00 AM 10/19/02 4:31:00 PM 10/20/02 12:51:00 AM 10/20/02 9:11:00 AM 10/20/02 5:31:00 PM 10/21/02 1:51:00 AM 10/21/02 10:11:00 AM 10/21/02 6:31:00 PM 10/22/02 2:51:00 AM Apparent Power (kva)

31 Demo Welding Machine Voltage Sag Alarm setup Alarm logging Waveform capture 3 1

32 Electricity Consumption Characteristic of Welding Machine Standby Condition Working Condition Voltage sag was occurred and recorded by Power Analyzer (Alarm was displayed at the same time) Standby Condition Working Condition 3 2

Communicate and view data from meters with one simple device

Communicate and view data from meters with one simple device Communicate and view data from meters with one simple device PowerLogic EGX300 integrated gateway-server Web Monitoring Communications Plug and Play Plug into your energy usage with a simple mouse click

More information

Gain energy insight and control with PowerLogic. PowerLogic EGX300 integrated gateway-server

Gain energy insight and control with PowerLogic. PowerLogic EGX300 integrated gateway-server Gain energy insight and control with PowerLogic PowerLogic EGX300 integrated gateway-server Plug into your energy usage with a simple mouse click The PowerLogic EGX300 is an integrated gateway-server that

More information

Access valuable energy and power information from your system

Access valuable energy and power information from your system Access valuable energy and power information from your system PowerLogic Web-Enabled Network Components Buildings Industry Data Center PowerLogic Network Solutions Schneider Electric offers the Square

More information

scalable data centre energy management solution

scalable data centre energy management solution scalable data centre energy management solution scalable data centre energy management solution EcoMeasure - Scalable Data Centre Energy Management & Efficiency Measurement Solution by Workspace Technology

More information

StruxureWare Power Monitoring Expert 7.2 Functions and characteristics

StruxureWare Power Monitoring Expert 7.2 Functions and characteristics EB100263 Power Monitoring is an operationslevel supervisory software that provides a complete power management solution for industry, large commercial and institutional buildings, data centres, healthcare

More information

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800 Power-monitoring unit PowerLogic System Technical data sheet 2003 Power Meter Series 800 Function and characteristics PB100313 The PowerLogic Power Meter Series 800 offers all the high-performance measurement

More information

Power Solutions for Data Centers Metering and protection architecture guide

Power Solutions for Data Centers Metering and protection architecture guide Power Solutions for Data Centers Metering and protection architecture guide The purpose of this guide is to provide technical guidelines to designers and field engineers who specify metering and protection

More information

PowerLogic PowerView Software Restricted to Schneider Personnel. POWERLOGIC PowerView Power Monitoring Software Version 2.

PowerLogic PowerView Software Restricted to Schneider Personnel. POWERLOGIC PowerView Power Monitoring Software Version 2. POWERLOGIC PowerView Power Monitoring Software Version 2.0 Launch Document June 2008 1 Contents 1. INTRODUCTION...3 2. PRODUCT PRESENTATION...3 3. PRODUCT FEATURES AND BENEFITS...4 4. MARKETING OBJECTIVES...5

More information

Device Support in PowerLogic ION Enterprise 5.6 Service Pack 2

Device Support in PowerLogic ION Enterprise 5.6 Service Pack 2 70072-0189-00 TECHNICAL 08/2008 Device Support in PowerLogic ION Enterprise 5.6 Service Pack 2 This document outlines support in ION Enterprise 5.6 Service Pack 2 for PowerLogic CM3000 series/cm4000 series,

More information

PMCS. Integrated Energy Management Solution. Unlock the Full Potential of Power Networks Through Integration. Complete Solution. Informed Decisions

PMCS. Integrated Energy Management Solution. Unlock the Full Potential of Power Networks Through Integration. Complete Solution. Informed Decisions PMCS Integrated Energy Management Solution Unlock the Full Potential of Power Networks Through Integration Power Management Control System (PMCS) is a highly customizable, fully integrated end-to-end Energy

More information

Energy Management System (EMS)

Energy Management System (EMS) Energy Management System (EMS) Comprehensive Power Quality Analysis Customer Billing and Invoicing at a Glance ExpertPower software solution provides comprehensive energy management, billing, demand response,

More information

Manage critical infrastructure, energy, revenue, reliability and power quality.

Manage critical infrastructure, energy, revenue, reliability and power quality. Manage critical infrastructure, energy, revenue, reliability and power quality. Energy and Power Management Solutions for electric utilities The world s largest and most advanced range of meters and software

More information

Internet-Accessible Power Monitoring & Control Systems

Internet-Accessible Power Monitoring & Control Systems Internet-Accessible Power Monitoring & Control Systems By GE Specification Engineers Keith B. Brock, P.E. Robert P. Hansen, PhD, P.E. Introduction Accessing electrical system information from any location

More information

PowerLogic communication devices. EGX100 Ethernet gateway EGX300 Integrated gateway-server. Technical data sheet

PowerLogic communication devices. EGX100 Ethernet gateway EGX300 Integrated gateway-server. Technical data sheet PowerLogic communication devices EGX100 Ethernet gateway EGX300 Integrated gateway-server Technical data sheet 2011 PowerLogic EGX100 Ethernet gateway PE86138 Function The EGX100 serves as an Ethernet

More information

Station Automation Series COM600 Protection and control from ABB Future-proof Concept: Extensive Substation System Integration and Interoperability The Station Automation Series COM600 is a dedicated system

More information

Optimize your power network with data-driven decisions

Optimize your power network with data-driven decisions Optimize your power network with data-driven decisions StruxureWare Power Monitoring Expert software delivers the integrated information for maximizing network reliability and performance Power Monitoring

More information

Make your electric distribution network safe

Make your electric distribution network safe Make your electric distribution network safe Increase security and quality of electric distribution system Think energy From your problems... Why do you pay too much for bad power quality, insecurity and

More information

SECTION 16911 WEB-BASED POWER MONITORING COMMUNICATIONS SYSTEM

SECTION 16911 WEB-BASED POWER MONITORING COMMUNICATIONS SYSTEM WEB-BASED POWER MONITORING COMMUNICATIONS SYSTEM PART 1 GENERAL 01 02 03 04 SCOPE This section describes the metering, communications, and visualization requirements for a modular, scalable Web-based Power

More information

Power Meter Series 700

Power Meter Series 700 PowerLogic power-monitoring units Power Meter Series 700 Technical data sheet 2007 Functions and characteristics E90463 The PowerLogic Power Meter Series 700 offers all the measurement capabilities required

More information

Secure your electrical network. PACiS The Safety Solution for Healthcare Institutions

Secure your electrical network. PACiS The Safety Solution for Healthcare Institutions Secure your electrical network The Safety Solution for Healthcare Institutions Fast Secure : the solution for fault isolation and electrical network restoration in less than 500 ms 03 A Real Time System

More information

SECTION 16002C CAMPUS CENTRAL METERING SYSTEM DESIGN CRITERIA 1. General

SECTION 16002C CAMPUS CENTRAL METERING SYSTEM DESIGN CRITERIA 1. General SECTION 16002C CAMPUS CENTRAL METERING SYSTEM DESIGN CRITERIA 1. General A. Electrical usage on the Brown campus is presently monitored by a Siemens-brand, web-based central metering system, which includes

More information

Types of Electrical Meters in Data Centers

Types of Electrical Meters in Data Centers Types of Electrical Meters in Data Centers White Paper 172 Revision 1 by David Kidd and Wendy Torell > Executive summary There are several different types of meters that can be designed into a data center,

More information

Unite your power network

Unite your power network Unite your power network StruxureWare Power Monitoring software Maximize operational efficiency, optimize power distribution, and improve bottom-line performance Healthcare StruxureWare Power Monitoring

More information

SCADA Controlled Multi-Step Automatic Controlled Capacitor Banks & Filter Banks

SCADA Controlled Multi-Step Automatic Controlled Capacitor Banks & Filter Banks SCADA Controlled Multi-Step Automatic Controlled Capacitor Banks & Filter Banks Introduction SCADA (Supervisory Controlled and Data Acquisition) controlled multi-step metalenclosed automatic capacitor

More information

Square D Model 6 Motor Control Centers

Square D Model 6 Motor Control Centers Square D Model 6 Motor Control Centers with Ethernet Communications What is industrial Ethernet? Over the past few years the use of Ethernet communications has spread into every corner of the business

More information

Power management. PowerLogic System. Catalogue 2004

Power management. PowerLogic System. Catalogue 2004 Power management PowerLogic System Catalogue 2004 PowerLogic System is PowerLogic System helps you control the cost, quality and reliability of electric power. With PowerLogic System, you can determine

More information

Simple Electrical Utility Cost Allocation Solutions

Simple Electrical Utility Cost Allocation Solutions Simple Electrical Utility Cost Allocation Solutions PowerLogic High Density Metering Advanced Submetering and Multi-Tenant Metering Buildings Retail Multi Residential DATA CENTER SOLUTIONS For More Information:

More information

Low Voltage Products

Low Voltage Products Low Voltage Products ABB Power Quality Filters: The most efficient solution for active filtering of harmonics, smooth reactive power compensation and load balancing. Enabling trouble-free and efficient

More information

PowerLogic energy & power management systems

PowerLogic energy & power management systems PowerLogic energy & power management systems Product range overview for industry, buildings and critical infrastructure The world s largest and most advanced range of software and meters for helping organizations

More information

Power Monitoring for Modern Data Centers

Power Monitoring for Modern Data Centers Power Monitoring for Modern Data Centers December 2010/AT304 by Reza Tajali, P.E. Square D Power Systems Engineering Make the most of your energy SM Revision #1 12/10 By their nature, mission critical

More information

Modbus Communications System for Micrologic A, P, and H Trip Units

Modbus Communications System for Micrologic A, P, and H Trip Units Modbus Communications System for Micrologic A, P, and H Trip Units (Four-Wire Modbus System without Smart System Communication) Instruction Bulletin 0613IB1201 R06/15 06/2015 Retain for future use. Hazard

More information

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D 7000/7000C/7020 Multi-instrument 4921210109D Features Measurements All 3-phase AC measurements True RMS Replaces analogue meters Demand on each phase current Accuracy U, I and F class 0.5 Other values

More information

21 st Century Facilities

21 st Century Facilities Electrical Testing 21 st Century Facilities Facility Owners face tough challenges 24 X 7 reliability needed Non linear loads cause harmonics VFD Computers Switching transients disrupt operations Less customer

More information

Reducing Energy Costs with Peak Shaving in Industrial Environments

Reducing Energy Costs with Peak Shaving in Industrial Environments Reducing Energy Costs with Peak Shaving in Industrial Environments Speaker : Phillip Yeung Asia Pacific Business Development Power Monitoring & Control Seminar 70SE01 1 Summary I. Introduction II. Monitoring

More information

WinPM.Net. Web-enabled Software. Power Monitoring. Answers for industry.

WinPM.Net. Web-enabled Software. Power Monitoring. Answers for industry. WinPM.Net Web-enabled Software Power Monitoring Answers for industry. WinPM.Net Web-enabled software A complete energy information management solution for your business allowing you to process, analyze,

More information

Power quality monitoring and analysis with reliability

Power quality monitoring and analysis with reliability Power quality monitoring and analysis with reliability PowerLogic CM4000 series circuit monitors Buildings Industry Data Center Intelligent metering and control devices Whether in offices, classrooms,

More information

Eaton s E-Series protective relay family

Eaton s E-Series protective relay family E-Series protective relays Feeder distribution relays Motor relays Transformer relays Generator relays Eaton s E-Series protective relay family Microprocessor-based design Eaton s E-Series relay family

More information

Power Monitoring and Control Systems Catalog. Class 3000

Power Monitoring and Control Systems Catalog. Class 3000 Power Monitoring and Control Systems Catalog Class 3000 Table of Contents Power Monitoring and Control Systems Introduction... Page 4 Power Meters... Page 8 Circuit Monitors... Page 12 System Manager

More information

Flexible solutions for. Office Buildings. Solutions for secure and optimized Power & Data distribution. Building a New Electric World

Flexible solutions for. Office Buildings. Solutions for secure and optimized Power & Data distribution. Building a New Electric World Flexible solutions for Office Buildings Solutions for secure and optimized Power & Data distribution Building a New Electric World Schneider Electric in Office Buildings Schneider Electric is committed

More information

Application Note: Monitoring Branch Circuit Loads in Critical Facilities

Application Note: Monitoring Branch Circuit Loads in Critical Facilities Application Note: Monitoring Branch Circuit Loads in Critical Facilities Description of application: The AcquiSuite data acquisition server (DAS) from Obvius is used to monitor the electrical loads and

More information

Enhance Power Equipment Reliability with Predictive Maintenance Technologies

Enhance Power Equipment Reliability with Predictive Maintenance Technologies Enhance Power Equipment Reliability with Predictive Maintenance Technologies November 2012/1910DB1208 by S. Frank Waterer, Electrical Engineerinig, Fellow Schneider Electric USA, Inc. Make the most of

More information

Energy efficiency and cost reduction solutions for industry. PowerLogic application brochure

Energy efficiency and cost reduction solutions for industry. PowerLogic application brochure Energy efficiency and cost reduction solutions for industry PowerLogic application brochure Energy insight to reduce costs and increase energy efficiency. The challenge Resource consumption is one of the

More information

ADMS(Advanced Distribution Management System ) in Smart Grid

ADMS(Advanced Distribution Management System ) in Smart Grid ADMS(Advanced Distribution Management System ) in Smart Grid 柯 佾 寬 博 士 Yi-Kuan Ke, Ph.D. 2014/03/28 Smart Grid Solution Smart Grid Solution Overview Smart Grid Solutions Smart Network Operation - Distribution

More information

System Manager Software Installation Notes

System Manager Software Installation Notes System Manager Software Installation Notes Version 4.0 Service Update 2 63220-060-241B1 Retain for future use. Use this instruction sheet when you install the System Manager Software version 4.0, Service

More information

Products Range Overview. Products Range Overview. The ZigBee Plug & Play wireless Network for Building and Industrial Applications

Products Range Overview. Products Range Overview. The ZigBee Plug & Play wireless Network for Building and Industrial Applications The ZigBee Plug & Play wireless Network for Building and Industrial Applications Energy Management Renewable Monitoring Environment Monitoring Open Modbus Integration Products Range Overview Products Range

More information

PowerLogic Selection Guide Monitoring & Metering Devices for Every Level of Your Power System

PowerLogic Selection Guide Monitoring & Metering Devices for Every Level of Your Power System PowerLogic Selection Guide Monitoring & Metering Devices for Every Level of Your Power System PowerLogic Monitoring and Metering Results in Savings with a Quick Return on Your Investment Utility costs

More information

For a phase-to-phase voltage between 100 V and 1000 V. The standard ratings are: 400 V - 690 V - 1000 V (at 50 Hz)

For a phase-to-phase voltage between 100 V and 1000 V. The standard ratings are: 400 V - 690 V - 1000 V (at 50 Hz) 24 1. NETWORK CONFIGURATIONS definition Standard IEC 38 defines voltage ratings as follows: - Low voltage () For a phase-to-phase voltage between 100 V and 1000 V. The standard ratings are: 400 V - 690

More information

ABB PSPS Erich Steinmann; Generator control-2013

ABB PSPS Erich Steinmann; Generator control-2013 ABB PSPS Erich Steinmann; Generator control-2013 GENERATOR CONTROL THE MODULAR SOLUTION FOR GENERATORS To make sure that power is efficiently converted into electric energy, it is necessary to supervise

More information

WebMeter Internal Web Server Feature

WebMeter Internal Web Server Feature 70072-0116-10 TECHNICAL 12/2007 WebMeter Internal Web Server Feature Several Ethernet equipped PowerLogic ION meters offer WebMeter capability, allowing you to view meter data and perform basic meter configuration

More information

Square D Power Management Services. Complete Custom Solutions for Your Power System

Square D Power Management Services. Complete Custom Solutions for Your Power System Square D Power Management Services Complete Custom Solutions for Your Power System The Total Power Management Solution Power. Managing it more efficiently and productively can give you a competitive edge.

More information

ION Tips and Tricks. Q&A Session PowerLogic ION Users Conference 2009

ION Tips and Tricks. Q&A Session PowerLogic ION Users Conference 2009 ION Tips and Tricks Q&A Session PowerLogic ION Users Conference 2009 Kevin Batycki Schneider Electric Services & Projects Business Manager, Solutions Sales Engineering Phone: +1-250-652-7126 Fax: +1-250-544-0217

More information

Electrical Monitoring and Control System Solution. Guideform Specification

Electrical Monitoring and Control System Solution. Guideform Specification Electrical Monitoring and Control System Solution Guideform Specification 1 SYSTEM... 2 1.1 Overview... 2 1.2 System Solution Functional... 2 1.2.1 Monitoring... 2 1.2.2 Power Quality... 4 1.2.3 Cost Allocation

More information

Power Meter Series 800

Power Meter Series 800 PowerLogic power-monitoring units Power Meter Series 800 Technical data sheet 2007 Functions and characteristics E90463 PB101813-51 PB101823-50 DB111799 Front view of Power Meter Series 800 meter with

More information

MONITORING DEVICE FITTED ON-BOARD A MV CIRCUIT-BREAKER, IN REMOTE AS WELL AS LOCAL ACCESS

MONITORING DEVICE FITTED ON-BOARD A MV CIRCUIT-BREAKER, IN REMOTE AS WELL AS LOCAL ACCESS MONITORING DEVICE FITTED ON-BOARD A MV CIRCUIT-BREAKER, IN REMOTE AS WELL AS LOCAL ACCESS Marc NOUVELLON marc_nouvellon@mail.schneider.fr Alain BILLET alain_billet@mail.schneider.fr Laurent GUISE laurent_guise@mail.schneider.fr

More information

TURBOtech srl. SED-635 Digital Excitation System. Industrial Electronics Sector FEATURES

TURBOtech srl. SED-635 Digital Excitation System. Industrial Electronics Sector FEATURES SED-635 Digital Excitation System SED-635 is a complete excitation system capable of adapting to control synchronous generators of any size. The integration of the TOUCH SCREEN operator interface and a

More information

7. Reactive energy compensation

7. Reactive energy compensation 593 7. Reactive energy compensation 594 7. REACTIVE ENERGY COMPENSATION Reactive energy compensation is an important element for reducing the electricity bill and improving the quality of the electrical

More information

Power Xpert Gateway 800E

Power Xpert Gateway 800E Technical Data TD152006EN Power Xpert Gateway 800E Delivers real-time, Web-enabled monitoring of electrical distribution and control equipment Product snapshot The Power Xpert Gateway 800E is typically

More information

Electric Power Distribution

Electric Power Distribution Electric Power Distribution A S Pabla Consulting Engineer and Former Chief Engineer Punjab State Electricity Board McGraw-Hill New York Chicago San Francisco Lisbon London Madrid Mexico City Milan New

More information

CRITICAL POWER MONITORING CPM20/CPM21 DETAILS

CRITICAL POWER MONITORING CPM20/CPM21 DETAILS CRITICAL POWER MONITORING CPM20/CPM21 DETAILS The Starline Critical Power Monitor (CPM) is a distributed data acquisition system that enables Current and Power monitoring in busway systems. Each phase

More information

Test & Data Management Software

Test & Data Management Software Test & Data Management Software TDMS protective relays energy meters transducers power quality CT-VT-PT transformers ground grid circuit breakers batteries surge arresters The Integrated Testing Solution

More information

You were seeking a protocol translator. Eaton delivered a vital data flow processor.

You were seeking a protocol translator. Eaton delivered a vital data flow processor. You were seeking a protocol translator. Eaton delivered a vital data flow processor. Your power system is a critical, integral part your organization s technological infrastructure. Ensuring availability,

More information

Il Progetto INTEGRIS. Risultati e nuove prospettive per lo sviluppo delle Smart Grid October 2nd 2013 Brescia

Il Progetto INTEGRIS. Risultati e nuove prospettive per lo sviluppo delle Smart Grid October 2nd 2013 Brescia Il Progetto INTEGRIS. Risultati e nuove prospettive per lo sviluppo delle Smart Grid October 2nd 2013 Brescia From INTEGRIS a solution architecture for energy smart grids Jean Wild - Schneider Electric

More information

www.electroind.com. March 15th 2005 EI Solutions - Submetering 1

www.electroind.com. March 15th 2005 EI Solutions - Submetering 1 . March 15th 2005 EI Solutions - Submetering 1 What is Submetering? Electric Service Master Meter Utility Owned POCC Utility Billing Point Sub Meter Electric Distribution Sub Meter Sub Meter Sub Meter

More information

ENERGY AUDITING AND MONITORING IN COMPANIES

ENERGY AUDITING AND MONITORING IN COMPANIES ENERGY AUDITING AND MONITORING IN COMPANIES Introduction To implement Article 8 (-6) of the EU Energy Efficiency Directive (0/7/EU), the UK government has set up ESOS (Energy Savings Opportunity Scheme)

More information

Measuring and monitoring units VAMP 96 VAMP 260 WIMO 6CP10

Measuring and monitoring units VAMP 96 VAMP 260 WIMO 6CP10 Measuring and monitoring units VAMP 96 Measuring and monitoring units Main characteristics Intelligent measuring and monitoring units The VAMP and WIMO meters come with an extensive selection of pre-configured

More information

TX2123 RS485 TO ETHERNET ADAPTOR

TX2123 RS485 TO ETHERNET ADAPTOR TX2123 RS485 TO ETHERNET ADAPTOR Converts Datacomms between fibre optic Modbus TCP over Ethernet and hard-wired copper Modbus RTU over RS485 Fibre Optic MODBUS TCP/ IP Ethernet Copper MODBUS RTU RS485

More information

StruxureWare Power Monitoring Expert 7.2

StruxureWare Power Monitoring Expert 7.2 StruxureWare Power Monitoring Expert 7.2 System Design Guide 7EN02-0350-00 03/2014 StruxureWare Power Monitoring Expert 7.2 System Design Guide Safety information Safety information Important information

More information

Applications. diris_826_a_1_gb_cat

Applications. diris_826_a_1_gb_cat Measurement units NEW diris_824_a_1_cat Energy monitoring and management of low voltage/ high voltage electrical installations Function are measurement units which can provide all the functions offered

More information

Nu-Lec Training Modules

Nu-Lec Training Modules PTCC Controller Nu-Lec Training Modules Product Training Operator Training PTCC The Basics An overview of the construction and physical features of the Pole Top Control Cubicle PTCC Operation and Features

More information

TDMS Test & Data Management Software

TDMS Test & Data Management Software Test & Data Management Software TDMS protective relays energy meters transducers power quality CT-VT-PT transformers ground grid circuit breakers batteries surge arresters The Integrated Testing Solution

More information

AutoLog ControlMan. Remote Monitoring & Controlling Service

AutoLog ControlMan. Remote Monitoring & Controlling Service AutoLog 1 AutoLog ControlMan Remote Monitoring & Controlling Service Web browser based HMI / SCADA interface Server is hosted by Internet server hosting company Control units communicate wirelessly via

More information

SNMP-1000 Intelligent SNMP/HTTP System Manager Features Introduction Web-enabled, No Driver Needed Powerful yet Easy to Use

SNMP-1000 Intelligent SNMP/HTTP System Manager Features Introduction Web-enabled, No Driver Needed Powerful yet Easy to Use SNMP-1000 Intelligent SNMP/HTTP System Manager Features Monitors system fans, temperature, voltage, power supply, CPU fan, CPU temperature, Vcore, watchdog timer etc. Stand alone system monitoring, no

More information

How Do You Reduce Energy Costs And Prolong The Life Of Your Equipment?

How Do You Reduce Energy Costs And Prolong The Life Of Your Equipment? How Do You Reduce Energy Costs And Prolong The Life Of Your Equipment? PowerLogic PM800 series power meters Buildings Industry Data Center Compact power, energy and power quality meters The Square D PowerLogic

More information

Cahier technique no. 196

Cahier technique no. 196 Collection Technique... Cahier technique no. 196 Integration of local power generation in industrial sites and commercial buildings T. Hazel "Cahiers Techniques" is a collection of documents intended for

More information

Remote monitoring & control solutions for cathodic protection rectifier

Remote monitoring & control solutions for cathodic protection rectifier G Remote monitoring & control solutions for cathodic protection rectifier FF-Automation Finnish automation manufacturer company Focused on remote monitoring & control solutions AutoLog RTU Series AutoLog

More information

Monitoring & Control of Small-scale Renewable Energy Sources

Monitoring & Control of Small-scale Renewable Energy Sources Small Scale Renewable Energy Sources and Energy Saving: 6-17 th July 2009 Monitoring & Control of Small-scale Renewable Energy Sources Dr G A Taylor Brunel Institute of Power Systems Brunel University,

More information

Paralleling Switchgear

Paralleling Switchgear Paralleling Switchgear By Maurice D Mello, P.Eng. Systems Engineer, GE Consumer & Industrial, Canada What is Paralleling? Paralleling is the operation in which multiple power sources, usually two or more

More information

Medium voltage products UniSec for Smart Grid Air-insulated medium-voltage secondary distribution switchgear

Medium voltage products UniSec for Smart Grid Air-insulated medium-voltage secondary distribution switchgear Medium voltage products UniSec for Smart Grid Air-insulated medium-voltage secondary distribution switchgear Index 3 Overview 4 Standard Levels 6 Monitoring & Control 7 Measurements 8 Protection & Logic

More information

Brochure. Electricity meters For increased awareness

Brochure. Electricity meters For increased awareness Brochure Electricity meters For increased awareness Strike the perfect balance with EQ meters In the World Energy outlook for 2012 the International Energy Agency (IEA), states: A significant share of

More information

Overview. 1. GPS data tracking via GSM SMS / GPRS. 2. GPS data logging in internal memory. 3. Alarm alert via GSM SMS / Dialing / GPRS

Overview. 1. GPS data tracking via GSM SMS / GPRS. 2. GPS data logging in internal memory. 3. Alarm alert via GSM SMS / Dialing / GPRS Vehicle or Personal Position Tracking Vehicle Status and Speed Tracking Auto Accident Report Global Position System (GPS) Navigation System Anti theft Alarm System Overview 1. GPS data tracking via GSM

More information

Power Management Systems Predictive Maintenance & Energy Sourcing Opportunities

Power Management Systems Predictive Maintenance & Energy Sourcing Opportunities Power Management Systems Predictive Maintenance & Energy Sourcing Opportunities James F. Lawrence Project Engineer Boise Cascade Wallula, WA Presented at the IEEE IAS Pulp & Paper Industry Committee Conference:

More information

Liebert GXT MT+ CX UPS, 1000VA - 3000VA Intelligent, Reliable UPS Protection. AC Power for Business-Critical Continuity

Liebert GXT MT+ CX UPS, 1000VA - 3000VA Intelligent, Reliable UPS Protection. AC Power for Business-Critical Continuity Liebert GXT MT+ CX UPS, 1000VA - 3000VA Intelligent, Reliable UPS Protection AC Power for Business-Critical Continuity Liebert GXT MT+ CX UPS, 1000VA -3000VA Intelligent, Reliable UPS Protection Liebert

More information

Executive Summary. Technical Description

Executive Summary. Technical Description Executive Summary The Cellwatch system is built using modules. The majority of the system is constructed with Data Collection Modules (DCMs). The DCMs are optically linked to Control Units (CUs) that in

More information

How To Use The Sunny Central Communication Controller

How To Use The Sunny Central Communication Controller Technical Information SUNNY CENTRAL COMMUNICATION CONTROLLER Content The Sunny Central Communication Controller is an integral part of the central inverter which is responsible for establishing the connection

More information

13. Electrical network design methodology and application example

13. Electrical network design methodology and application example 873 13. Electrical network design methodology and application example 874 13. ELECTRICAL NETWORK DESIGN METHODOLOGY AND APPLICATION EXAMPLE The profitability of an industrial installation is directly linked

More information

Intelligent chart recorder for compressed air and gases. Measurement - control - indication - alarm - recording - evaluation

Intelligent chart recorder for compressed air and gases. Measurement - control - indication - alarm - recording - evaluation DS 500 Intelligent chart recorder for compressed air and gases Measurement - control - indication - alarm - recording - evaluation new Advantages at a glance: Clear layout: 7" colour screen with touch

More information

SCADA Systems Automate Electrical Distribution

SCADA Systems Automate Electrical Distribution SCADA Systems Automate Electrical Distribution PC-based supervisory control and data acquisition systems increase uptime, cut costs and improve utilization. A White Paper from InduSoft Fabio Terezinho

More information

Modular Enterprise-wide Energy Management Monitoring System

Modular Enterprise-wide Energy Management Monitoring System Modular Enterprise-wide Energy Management Monitoring System www.electroind.com Monitor Electrical Power Reliably Perform Advanced Power Quality Analysis Centralized Ethernet Based SCADA System Advanced

More information

StruxureWare Power Monitoring Expert 8.0

StruxureWare Power Monitoring Expert 8.0 StruxureWare Power Monitoring Expert 8.0 Design Guide 7EN42-0109-00 05/2015 StruxureWare Power Monitoring Expert System Design Guide Safety information Safety information Important information Read these

More information

PowerLogic ION Enterprise 5.6

PowerLogic ION Enterprise 5.6 PowerLogic ION Enterprise 5.6 Power Management Software User Guide April 2007 Notices This section describes the symbols used in this guide. Danger This alerts you to things that may cause serious injury

More information

Power Quality Standards for Electric Service

Power Quality Standards for Electric Service Power Quality Standards for Electric Service Effective June 1, 2008 A transition period will exist from June 1 through December 31, 2008 in which installations may be approved and connected as long as

More information

Power Monitoring Expert software. Benoit Barbalat Energy Management Solutions Schneider Electric Canada

Power Monitoring Expert software. Benoit Barbalat Energy Management Solutions Schneider Electric Canada Power Monitoring Expert software Benoit Barbalat Energy Management Solutions Schneider Electric Canada Drivers for Energy Management Generate savings Procurement Incentives Better business performance

More information

ISIO 200. Binary Input/Output (I/O) Terminal with IEC 61850 Interface

ISIO 200. Binary Input/Output (I/O) Terminal with IEC 61850 Interface ISIO 200 Binary Input/Output (I/O) Terminal with IEC 61850 Interface Compact and Easy ISIO 200 Put your Binary I/Os where you need them ISIO 200 is a simple and versatile binary I/O terminal with IEC 61850

More information

--.;...--""""1. AA OvERVIEW OF PO'M:R MoNITORING X X X X X X X

--.;...--1. AA OvERVIEW OF PO'M:R MoNITORING X X X X X X X Justifying and Planning an Energy Monitoring System In an Existing Plant 1995 IEEE. Reprinted with permission, from Proceedings of the Petroleum and Chemical Industry Conference, Denver, Colorado, September

More information

TAC XentaTM 555 Embedded Web Server for MicroNet

TAC XentaTM 555 Embedded Web Server for MicroNet TM Embedded Web Server for MicroNet The ( ) is a multi-functional presentation system with a built-in (embedded) web server. 02 Features offers MicroNet and Satchnet users a feature rich web solution by

More information

..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark...

..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark... ..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark... TIME MARK CORPORATION 11440 EAST PINE STREET TULSA, OK 74116 USA tel 918 438-1220 fax 918 437-7584 www.time-mark.com

More information

FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid

FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars Presented By: Greg Pelster & Robert Schmid FFI Ferrie, Franzmann Industries LOW VOLTAGE SWITCHGEAR & LOW VOLTAGE

More information

CRE Monitor Instructions Manual

CRE Monitor Instructions Manual CRE Monitor Instructions Manual CRE TECHNOLOGY believes that all information provided herein is correct and reliable and reserves the right to update at anytime. CRE TECHNOLOGY does not assume any responsibility

More information

PowerLogic ION Setup 3.0

PowerLogic ION Setup 3.0 PowerLogic ION Setup 3.0 Meter configuration software User guide 7EN02-0312-00 03/2012 Contents Safety information 7 Chapter 1: Safety precautions 9 Chapter 2: Introduction 11 ION Setup features 12 Your

More information

Technology Spotlight on Cellular Data Networking for SCADA system networks. Presented by Teamwork Solutions, Inc.

Technology Spotlight on Cellular Data Networking for SCADA system networks. Presented by Teamwork Solutions, Inc. on Cellular Data Networking for SCADA system networks Presented by Teamwork Solutions, Inc. Wireless (Cellular) Data Networking Internet SCADA Server How Wireless (Cellular) Data Networking Works Dynamic

More information