WIRE & CABLE PRODUCT INFORMATION GUIDE
|
|
|
- Roland Snow
- 9 years ago
- Views:
Transcription
1
2 WIRE & CABLE PRODUCT INFORMATION GUIDE Nexans manufactures a wide range of cables for residential, commercial, industrial and utility installations. All products are made in ISO 9002 registered plants. Product leaflets are available for general information about the products contained in each of the following groups. ARMOURED CABLES COMPONENT & SPECIALTY WIRES CONDUIT CABLES & DIRECTLY BURIED CABLES CONTROL CABLES COPPER & ALUMINUM CONDUCTORS HOUSE, FARM & APARTMENT WIRE INSULATIONS & JACKETS OVERHEAD PRIMARY CONDUCTORS OVERHEAD SECONDARY & SERVICE CABLE POWER CABLE 5 KV TO 46 KV UNDERGROUND SECONDARY & SERVICE CABLE The descriptions in these leaflets are very brief, and are for general guidance only. For specific installations you should check with a licensed electrician, or the Electrical Inspection Department in your area to confirm the rules and regulations that cover a specific installation. Nexans accepts no liability for injury or damage resulting from incorrect installation and/or use of its products Allstate Parkway, Markham, Ontario, Canada L3R 0Z7 Phone: (905) Fax: (905)
3 FLAME TEST RATINGS - CSA FT RATINGS Flame test ratings indicate how readily fire will spread along wire and cable. The tests are a complex formula of time, distance, diameter, and set-up; but the following gives a general idea of what happens. FT1 A bunsen burner flame is applied to a vertical sample for five 15 second applications. Burning must cease within 60 seconds of removal of the burner, with no more than 25% of a paper indicator charred. FT1 is applicable for wires such as NMD90 and TW75 which are used in combustible buildings. UL VW1 is similar to CSA FT1. FT2 A bunsen burner flame is applied to a horizontal sample for five 15 second applications. The charred portion must not exceed 100mm from end to end, and there shall be no flaming particles dropping from the sample. Products such as some S, SJ and HPN cords, as well as SIS wire, are rated FT2. FT3 This rating has been deleted. FT4 Cables are strapped to an 8-foot vertical section of ladder tray and burned at 70,000 BTU for 20 minutes. The charred portion shall not exceed 1.5 meters. The FT4 test is used on cables intended for tray or shaft applications. The CSA FT4 test is similar to UL1581 paragraph 1160, but FT4 is more stringent. FT4 cables can be used in non-combustible buildings. Nexans Teck90, RA90 Corflex and ACWU90 are FT4 rated. FT5 Flame is applied to a horizontal sample, similar to the FT2 fire test but with a much larger burner. The flame must extinguish in less than 4 minutes and the burn length shall not exceed 150mm. The FT5 test is applicable to portable cables used in underground work areas such as mines and tunnels. FT6 Cable samples on a horizontal tray in a tunnel type of chamber are burned at 300,000 BTU for 20 minutes. Flame spread not to exceed 1.5 meters, with a smoke density during the test of (a) 0.5 peak; and 0.15 maximum average. FT6 is used for cable in return air plenums. The CSA FT6 test is similar to NFPA and UL S No CSA FT6 rated power cables are presently available in Canada. Some provinces allow FT4 single conductor cables to be used in these locations. Otherwise, cable in conduit is the permitted installation method in return air plenums. AG14 AG14 refers to the acid gas given off during burning of plastics used in cable. Normal PVC would produce approximately 30%, by weight, of acid gas during combustion. AG14 indicates materials will produce less than 14% acid gas during combustion. Nexans Teck90, RA90 Corflex and ACWU90 all have insulation and jacket materials rated AG14.
4 ARMOURED CABLES ARMOURED CABLE FOR COMMERCIAL, INDUSTRIAL & APARTMENT USE AC90 BX AC9O is used in stores, small factories, apartments and similar buildings, where some mechanical protection is required. It has RW90 insulated 600 volt conductors (usually copper) cabled with a bare bonding wire, and enclosed in armour made of interlocked aluminum strip. AC90 must not be buried, nor used in wet locations. It is an inexpensive alternative to wire in conduit. CASH REGISTERS & COMPUTERS AC90 ISO-BX DIRECT BURIAL CABLE FOR MULTI-UNIT RESIDENTIAL, COMMERCIAL AND SOME INDUSTRIAL FEEDERS ACWU ISO-BX is the same as AC90 BUT has an additional GREEN conductor, providing an isolated insulated ground, to give extra protection to sensitive equipment. ISO-BX is 600 volt rated. ACWU is the same as AC90 but has a PVC plastic jacket over the armour. This permits its use for direct earth burial and in wet locations. Conductors are usually aluminum alloy, but may also be copper. In single conductor cables there is a concentric copper bonding wire over the insulation, which is sized in accordance with the electrical code. When marked "HL" ACWU can be used in hazardous locations. It is a cheaper and less robust cable than Teck. ACWU is 600 volt rated. Nexans ACWU is rated FT4, HL and AG14. MULTI-UNIT RESIDENTIAL, COMMERCIAL & SOME INDUSTRIAL FEEDERS CORFLEX RA90 CORFLEX (CSA type RA90) is similar to ACWU - but DIFFERENT. There is no bonding wire because Corflex has an aluminum sheath that is a 'tube' (not a wrapped strip like ACWU) that can be used as an equipment bond. It is water and gas tight, can be bent by hand, and holds the shape made. Approved for use in hazardous locations it has excellent fire, water and crush resistance. It can be installed on hangers, as it holds its shape better than interlocked armour cables. Corflex is excellent for use in high rise apartments, hospitals, schools, shopping centres and factories. Corflex is 600 volt rated. Available in single conductors of both copper and aluminum alloy, Nexans Corflex is rated FT4, HL and AG14. INDUSTRIAL INSTRUMEN- TATION CONTROL DATATRANS DATATRANS is a cable made of pairs or triads (bundles of 2 or 3 conductors) shielded, cabled with an overall shield and jacket, then encased in aluminum interlocked armour and a gray PVC jacket. It is common in both 300 volt and 600 volt ratings, and is approved for direct burial. Its handling characteristics are similar to Teck, and it is commonly used in industrial applications to carry signals from process monitoring and data acquisition equipment. Non-armoured construction can also be manufactured.
5 ARMOURED CABLES VARIABLE FREQUENCY DRIVES DriveRx DriveRx, developed in response to requirements identified in studies by leading drive manufacturers, DriveRx helps to reduce serious problems which may occur in variable frequency drive applications. These problems might otherwise result in costly downtime. It is stocked in 3 conductor 12 gauge to 500 MCM. DriveRx is rated 1000 volt and uses the same specially designed connectors as RA90 Corflex. VFD cable is a readily available and economical way to avoid expensive system component failure and production interruptions due to the special characteristics resulting from the use of high frequencies in VFDs. Also known as Variable Speed Drive cable, DriveRx is rated FT4, HL and AG14. FIRE ALARM, SIGNAL, SECURITY, TWO-WAY EMERGENCY COMMUNICATION SYSTEMS SECUREX SECUREX is mostly 18 gauge solid copper conductors, PVC plastic insulated and colour coded. The conductors are cabled then covered with a red PVC jacket. Shielded unarmoured Securex is also available. Rated 300 volts, Securex is used in houses to connect the central furnace and the thermostat. The armoured version has an aluminum interlocked armour over the jacket. FT4 rated, unarmoured Securex in metal conduit and armoured Securex can be used as fire alarm cable. Securex must NOT be used as a power supply wire to lights or outlets. Securex is readily available up to 30 conductors. Some provincial inspection authorities allow its use in return air plenums. MAJOR INDUSTRIAL INSTALLATIONS TECK90 TECK is the most widely used, abuse resistant, easy to install and readily available cable for industrial use. It has been the backbone of power systems in paper mills, petrochemical installations, mines and industrial plants for almost 50 years. Usually made of copper conductors with RW90 insulation, Teck is rated 600 volts in gauge and 1000 volts in sizes 8 gauge and larger. We also stock 1000 volt 2C#12, 3C#12 and 3C#10. Teck is also available in shielded and non shielded medium voltage constructions. Conductors in gauge are compressed strand; #8 and larger are compact. There is a PVC jacket between the conductors and the interlocked aluminum armour so that if the cable is crushed the edge of the armour will not cut the insulation. Covered by an outer PVC jacket Teck has excellent fire, water and cold-bend characteristics. It may be direct buried and used in wet locations. "HL" marked material may be used in hazardous locations. Nexans Teck90 is rated FT4, HL and AG14. MINE & ELEVATOR SHAFTS VERTEK VERTEK is non-stock, specially modified Teck for vertical installations, such as mineshafts, elevator shafts and cableways. It is designed to ensure that the core does not slip out of the armour when running vertically for long distances. It usually has galvanized steel interlocked armour. Vertek voltage ratings range from 600 volts to 15 kv.
6 COMPONENT & SPECIALTY WIRES RAILWAY SIGNAL CABLE RAILWAY SIGNAL CABLE has single or multiple copper conductors, polyethylene (PE) insulation and a PE jacket and is used in railway signaling applications. This 600 volt cable is made to CPR Specification 100. There is no CSA or UL standard for this product. SWITCHBOARD WIRE SIS SIS is similar to TEW but has cross-linked polyethylene insulation rated plus 90 C to minus 40 C. Unlike its predecessor 'TBS' switchboard wire, it has no overall braid covering, making it cleaner to use. SIS is FT2 rated and 600 volts. OUTDOOR EXTENSION CORD SJTW SJTW is for use outdoors on trimmers, lawn mowers, barbecues, and similar devices. It is rated 300 volts, and has a cold temperature and water-resistant yellow PVC jacket. Other jacket colours are available on special order. SJTW is FT1 rated. STREETLIGHT WIRE SLV SLV has two solid copper conductors, 600 volt PVC insulated, laid parallel and encased in a black, low temperature PVC jacket. It is designed to run from the base of hollow streetlight poles to the bracket and on to the lamp holder. There is no CSA or UL standard for this product. INTERNAL AUTOMOTIVE WIRING SXL (SAE) SXL made to the SAE J1128 standard is cross-linked polyethylene insulated giving it excellent resistance to high and low temperatures, oil, abrasion and aging. High temperature wire could go in engine compartments. INTERNAL WIRING OF EQUIPMENT TEW and TEWN TEW is used inside electrical equipment to connect the various components, and in many other applications such as lighting fixtures. TEW with a nylon coating (TEWN) is used in lighting ballasts. TEW is made of copper, with 105 C 600 volt PVC insulation. Solid or stranded copper conductor TEW is available from stock in a wide range of colours. It is NOT approved for use as distribution wire in conduit. ENERGY CONTROL SYSTEM WIRE TFN (UL) TFN is used with sophisticated energy-saving installations where the lighting and ventilation systems in a building are controlled and co-ordinated by a central computer. This 600 volt wire is 2 or 3 conductors, in various colour combinations and gauges depending on the system (most commonly #16). Each wire is PVC insulated with a thin 'skin' of nylon over the PVC to add mechanical strength. TRANSFORMER DROP TRANSFORMER DROP is stranded copper, with a thick covering of track resistant black polyethylene. It connects the transformer to the primary supply line. If made with medium hard copper it can be formed to special shapes, (such as a right angle offset), if required. Transformer drop wire has no voltage rating. There is no CSA or UL, standard for this product.
7 COMPONENT & SPECIALTY WIRES AIRPORT RUNWAY LIGHTING CABLE AIRPORT SERIES LIGHTING CABLE 'ASLC' AIRPORT SERIES LIGHTING CABLE is designed for burial beside runways, to power the lights that guide aircraft to safe landings. It has a thick covering of cross-linked polyethylene, and is rated 5,000 volts unshielded. Normally it is #8 gauge and is the standard cable for this function in all Canadian airports. Nexans cable is CSA and DOT approved. AUTOMOTIVE, BATTERY OR BOOSTER CABLE BATTERY CABLE (SAE) BLASTING WIRE BATTERY CABLE is used for car and truck batteries, and also as battery jumper cable. It has a very flexible stranded copper conductor, covered with heat, cold and oil resistant CPE insulation. Made to SAE J1127 specification, battery cable is not suitable for use in buildings. BLASTING WIRE is used to electrically detonate explosives in mining operations. It has one or two PVC insulated copper conductors. Two conductor constructions have the conductors laid parallel like lamp cord and HPN. Blasting wire has no voltage rating and there is no CSA or UL standard for this product. INDUSTRIAL EQUIPMENT CONTROL CONTROL CABLES - INDUSTRIAL INTERNAL AUTOMOTIVE WIRING GPT (SAE) KETTLE, TOASTER and HEATER CORD HPN 90 and 105 INDUSTRIAL CONTROL CABLE controls equipment in industrial applications. Generally it has stranded copper conductors in sizes #14-10 gauge, but larger sizes are also manufactured. Control cable has 300 volt or 600 volt PVC or XLPE insulation and an overall PVC jacket. An overall shield under the jacket is also available. GPT made to SAE J1128 standard is general purpose automotive wiring, insulated with high performance PVC compound. HPN is made of stranded copper conductors laid parallel. HPN is insulated with CPE, a special compound which enables it to withstand heat and grease. It is not designed to be wet, and care should be taken to avoid this. Standard 300 volt HPN is 90 but 105 HPN can be special ordered. POLE & BRACKET STREET LIGHT WIRE MID RIP MID RIP, like SLV, runs from the base of hollow streetlight poles to the bracket and on to the lamp holder. Made like a very large lamp cord, Mid Rip is flat with a groove between the conductors, which can be ripped apart to allow terminating. There is no CSA or UL standard for this 600 volt PVC insulated product. SUBMERSIBLE PUMP CABLE PUMP CABLE is used to power electric pumps submerged in wells, ponds or similar places. Copper conductors are individually insulated with colour coded PVC (designated type TWU), then cabled together in various size and colour combinations. It is readily available in sizes #14 - #6. Pump cable is rated 600 volts, FT1.
8 DIRECTLY BURIED CABLES ARMOURED TYPES Most ARMOURED CABLES can be directly buried. These include: Teck90, ACWU90, RA90 Corflex, Armoured Datatrans and DriveRx VFD cable. More details about these cables can be found in the "Armoured Cable" leaflet. NMWU 300 Volts NMWU has copper conductors with thick PVC insulation; assembled with a bare copper bond wire; and encased in a thick PVC plastic jacket. Excellent for buried runs to lawn lights, sheds, garages, etc. and also for use to (and in) barns and animal pens. RWU Volts RWU90 is RW90 with thicker cross-linked polyethylene (XLPE) insulation for direct burial in earth or in duct and is rated 1000 volts. It is tough and has excellent water resistance. TWU Volts TWU-40 is similar to TW75 but has a thicker wall of PVC plastic insulation. It may be installed (with care) down to minus 40 C. It has a high temperature limit of +60 C. It is designed to be directly buried in the ground, but may be put in duct if desired. USEB Volts USEI75/ USEI9O 600 Volts USEB90 is preferred to USEI in some provinces. Instead of twisting the aluminum conductors together, they are laid parallel then surrounded by a copper concentric neutral and an overall PVC jacket. Contact your local electrical inspection authority before deciding whether to use USEI or USEB. USEI is normally made with aluminum conductors. USEI75 is insulated with polyethylene, and USEI90 is insulated with cross-linked polyethylene. Each insulated conductor is individually covered with a PVC jacket, and then cabled together. USEI is principally used for underground power supply to houses, trailer parks, etc. It is economical, and readily available from stock in many sizes.
9 CONDUIT CABLES RW Volts RW90 is insulated with cross-linked polyethylene (XLPE), over copper or aluminum conductors. It is mechanically and electrically very strong. Flame retardant jackets are available on special order. The XLPE insulation has very good cold weather characteristics, and excellent water resistance. It can be used in wet locations and underground ducts. RW90 is poor on ultraviolet (sunlight) resistance unless made with special additives and printed 'OUTDOOR' on the outside of the insulation. Our stock black RW90 #6 and larger is 'OUTDOOR'. T90/TWN Volts T90/TWN75 is copper conductor insulated with a thin layer of PVC plastic covered with a 'skin' of nylon (like nail varnish). It is very useful when a lot of conductors must be put into a small conduit. Solid and stranded conductors are available in many different colours. It is rated 90 C in dry locations, but only 75 C if wet. It must not be exposed to ultraviolet rays (sunlight) as it will crack. It is not as robust as RW90, and must be handled with care at low temperatures. TW Volts TW75 is a single copper wire covered with PVC plastic, commonly used for service entrances connecting the utility power supply conductors to the house or other building. It must be carefully handled at low temperatures but withstands both rain and ultraviolet rays from the sun. The most common service entrance sizes are stock. TW75 has mostly been replaced by T90/TWN75, with protection where exposed to sunlight. UNDERGROUND DUCTS RW90, TWN75 and TW75 may be installed in underground ducts, but must NOT be directly buried. When using conduit or duct these must be cleaned of any loose stones or sharp edges; and plenty of pulling compound should be used during installation in the ducts.
10 CONTROL CABLES CONTROL CABLE The Product Nexans Wire & Cable Control Cables are single and multi-conductor cables available in both 300V and 600V. These cables are all manufactured using the latest in production technology and computer aided manufacturing systems. There are a variety of features that can be chosen to further enhance the superior quality inherent in these cables. These features include flame retardancy, low acid gas emission and zero halogen content. The Application Nexans Wire & Cable Control Cables can be suitable for direct earth burial, for installation in ducts or conduit as well as open air conditions both inside and outside (subject to UV radiation) depending on the design parameters chosen. Nexans Wire & Cable Control Cables cables are suitable for continuous operation at 75 C and can be designed for wet or dry environments in addition to being sunlight resistant. The Approvals Nexans Wire & Cable are designed, manufactured and tested in accordance with the following specifications: ASTM B3: Soft or Annealed Copper Wire ASTM B8: Concentric Lay Stranded Conductors, Hard, Medium-Hard or Soft ASTM D 1248: Polyethylene Plastics Molding and Extrusion Materials ICEA S Standard for Control Cables AIRPORT RUNWAY LIGHTING CABLE AIRPORT SERIES LIGHTING CABLE ASLC AIRPORT SERIES LIGHTING CABLE is designed for burial beside runways, to power the lights that guide aircraft to safe landings. It has a thick covering of cross-linked polyethylene, and is rated 5,000 volts unshielded. Normally it is #8 gauge and is the standard cable for this function in all Canadian airports. Nexans cable is CSA and DOT approved.
11 CONTROL CABLES POLE & BRACKET STREET LIGHT WIRE MID RIP MID RIP, like SLV, runs from the base of hollow streetlight poles to the bracket and on to the lamp holder. Made like a very large lamp cord, Mid Rip is flat with a groove between the conductors, which can be ripped apart to allow terminating. There is no CSA or UL standard for this 600 volt PVC insulated product. RAILWAY SIGNAL CABLE RAILWAY SIGNAL CABLE has single or multiple copper conductors, polyethylene (PE) insulation and a PE jacket and is used in railway signaling applications. This 600 volt cable is made to CPR Specification 100. There is no CSA or UL standard for this product. TRANSFORMER DROP TRANSFORMER DROP is stranded copper, with a thick covering of track resistant black polyethylene. It connects the transformer to the primary supply line. If made with medium hard copper it can be formed to special shapes, (such as a right angle offset), if required. Transformer drop wire has no voltage rating. There is no CSA or UL standard for this product.
12 COPPER CONDUCTORS COPPER All COPPER conductors supplied by Nexans have a purity guaranteed not less than 99.8%. Virtually all are drawn from copper rod made at the Nexans factory in Montreal East, from copper supplied by Noranda's adjacent copper refinery. Common sizes of soft bare conductors are readily available from stock. COPPER - TINNED Copper conductors may be TINNED to resist corrosion or to make soldering easier. STRAND - COMPACT In COMPACT conductors each layer of wires in the conductor is compacted so that all the wires are segment shaped leaving no air spaces visible between the wires. This reduces the conductor diameter approximately 9% to 10%. Compact conductors are standard in large size Teck and most medium voltage power cable. STRAND - COMPRESSED COMPRESSED has the outer layer of wires in a stranded conductor smoothed, thereby reducing the diameter approximately 3%. Compressed conductor is used in all building wire. STRAND - FLEXIBLE and ROPE Used in small flexible conductors, BUNCHED strand is a group of very fine wires twisted together in a common direction: not concentrically. ROPE strands are assemblies of bunch-stranded members that are used in very flexible cables, such as welding cable. These strands are expensive, and used only where essential. STRAND - ROUND Conductors can be stranded in several different ways. The original was ROUND strand, in which a single solid center wire has other solid wires wrapped around it in layers. TEMPER Copper is most commonly supplied in soft (drawn) TEMPER. It is easy to pull into conduits, and to terminate. Medium hard and hard are seldom used, except where strength is needed such as going from pole-to-pole along streets, or as power supply conductors for streetcars or overhead cranes.
13 ALUMINUM CONDUCTORS ALLOYS The ALLOY used for many years has been EC grade (or alloy 1350). In recent years the need to improve aluminum's handling characteristics led to the introduction of the 8000 series of alloys (known as ACM). Alloy 8030 ACM is now standard in all Nexans aluminum conductor building wire products. Aluminum has approximately 61% of the conductivity of copper, therefore a larger sized conductor must be used to carry the same current as copper. Many conductors for use overhead, and directly buried are stocked. Aluminum RA90 Corflex, RWU90, RW90 and ACWU90 building wire are readily available. STRANDING Aluminum STRANDING is the same as for copper, except that it is not suitable for very fine flexible conductors, since the individual fine aluminum wires composing the strand are susceptible to breakage during manufacture and use. TEMPER Since all Nexans aluminum building wire conductors are made of ACM (alloy 8030) they must be heat treated before they are insulated. This heat treatment makes them a dead soft or zero TEMPER. Half hard, 3/4 hard and full hard tempers of alloy 1350 conductors are used in some cable constructions for overhead applications. UNIQUE INSTALLATION REQUIREMENTS The use of aluminum conductors is NOT as simple as copper. Aluminum (and its alloys) quickly form an oxide 'coat' and this can lead to faulty 'hot' connections. There are some UNIQUE INSTALLATION REQUIRE- MENTS for aluminum. The conductor must be wire brushed to remove the oxide, then immediately covered in a suitable inhibitor (such as Penetrox). Lugs and terminals must be designed for use with aluminum to ensure good conductivity, and evenly spread pressure to avoid cold flow. Before using aluminum conductors it is wise to obtain specific advice on proper installation methods. Aluminum can save some money on the initial cable purchase, but requires more care in installation and if improperly installed can cause serious problems. ACM aluminum alloys help to eliminate some of these problems with aluminum conductors but TIME, KNOWLEDGE and CARE are ESSENTIAL.
14 HOUSE, FARM & APARTMENT WIRE BELLS & BUZZERS ANNUNCIATOR or BELL WIRE ANNUNCIATOR and BELL WIRE are two common names for an inexpensive and widely used wire, comprising 2 or 3 insulated conductors twisted together, with NO overall covering. It may only be used on systems of 30 volts or less. The covering is thin, and not very good in cold weather so it must be handled carefully during installation. It is used on bells or buzzers which are powered through a step-down transformer. It must NEVER be used on full house power of 110 volts. LIGHT & OUTLET CIRCUITS NMD90 (White) CANADEX 300 Volt NMD9O is common house wire. It is designed for use indoors, in dry locations, and away from the weather. It must NOT be buried or used in wet locations. The slight dampness found in some basements will not hurt it. A bare copper bonding (ground) wire is always included to permit safe operation of attached equipment. The plastic covering is not designed for installation at low temperatures, and it is good practice, to warm the spools before unrolling the wire in winter. NMD90 always contains a white NEUTRAL wire, except for NMD (Red) HEATEX. ELECTRIC HEAT CIRCUITS NMD90 (Red) HEATEX 300 Volt NMD90 (Red) HEATEX is a variant of NMD90 CANADEX, with NO WHITE WIRE in the 2 conductor cable. This cable is designed for use on 230-volt systems where there is no NEUTRAL, therefore the cable has a black and a red conductor in addition to the bare bonding wire. To make identification easier it is usually supplied with a RED overall jacket. It should NOT be used on 110-volt systems as there is no neutral, and it is dangerous to use either the red or the black as a neutral. Large sizes are available for use with electric furnaces. BURIED CIRCUITS BARNS, SHEDS & LAWN LIGHTS NMWU SUPERVEX 300 Volt Although NMWU is similar in appearance to NMD, it is in fact quite different. This wire has very thick PVC insulation on the individual conductors, and is then covered with a thick PVC jacket making it suitable for direct burial. It is a very good cable to use for supplying a garage, garden shed or lawn lights. The #2 gauge and larger is suitable for 100 amps. NMWU can be used in wet locations, and in barns and other animal enclosures where not exposed to mechanical injury. SUBMERSIBLE PUMP CABLE PUMP CABLE is used to power electric pumps submerged in wells, ponds or similar places. Copper conductors are individually insulated with colour coded PVC (designated type TWU), then cabled together in various size and colour combinations. It is readily available in sizes #14 - #6. Pump cable is rated 600 volt, FT1.
15 HOUSE, FARM & APARTMENT WIRE SERVICE ENTRANCE OR SUPPLY WIRE RW Volt RW90, made with either copper or aluminum alloy conductor, is another wire type used for service entrances. The cross-linked polyethylene (XLPE) insulation has very good cold weather characteristics, and excellent water resistance. HOWEVER, it is poor on ultraviolet (sunlight) resistance unless made with special additives and printed 'OUTDOOR' on the outside of the insulation. Our stock black RW90 #6 and larger is 'OUTDOOR'. If it is not marked 'OUTDOOR' it can only be used away from sunlight, or may be used outdoors if covered with tape or other sunlight protection acceptable to the local electrical inspector. Extra care is required to terminate aluminum RW90. BURIED CIRCUITS RWU Volt RWU is a version of RW90 that can be direct buried in earth. This solid or stranded copper conductor, insulated with extra thick cross-link insulation is 1000 volt rated. A stock item, RWU can be used to bury circuits to or between buildings or outdoor lights. As with TWU, mechanical protection is usually required. THERMOSTAT & FIRE ALARM, SIGNAL, SECURITY, TWO-WAY EMERGENCY COMMUNICATION SYSTEMS SECUREX FAS/LVT 300 Volt SECUREX is mostly 18 gauge solid copper conductors, PVC plastic insulated and colour coded. The conductors are cabled then covered with a red PVC jacket. Shielded unarmoured Securex is also available. Rated 300 volts, Securex is used in houses to connect the central furnace and the thermostat. The armoured version has an aluminum interlocked armour over the jacket. FT4 rated, unarmoured Securex in metal conduit and armoured Securex can be used as fire alarm cable. Securex must NOT be used as a power supply wire to lights or outlets. Securex is readily available up to 30 conductors. Some provincial inspection authorities allow its use in return air plenums. SERVICE ENTRANCE OR SUPPLY WIRE TW Volt TW75 is a single copper wire covered with PVC plastic, commonly used for service entrances connecting the utility power supply conductors to the house or other building. It must be carefully handled at low temperatures. It withstands both rain and ultraviolet rays from the sun. BURIED CIRCUITS TWU Volt TWU-40 is a solid or stranded copper conductor, insulated with very thick PVC plastic insulation, good for direct burial in the earth. TWU-40 has very good low temperature characteristics. Inexpensive and readily available from stock, it may be used for direct buried circuits running to or between buildings or to outdoor lights. Mechanical protection will usually be required to keep stones and frost heaving from damaging it.
16 INSULATIONS EPR/EPDM ETHYLENE PROPYLENE RUBBER/ETHYLENE PROPYLENE DIENE MONOMER EPR/EPDM are synthetic rubbers used on cables in low and medium voltages. These rubbers are soft and pliable material, good on trailing cable used in mines and similar applications. It is not as tough mechanically as XLPE. Some manufacturers offer it as an alternative to XLPE, but Nexans is committed to XLPE which has a long and reliable history. PE POLYETHYLENE PE is widely used as an insulation on cables to be installed outdoors, exposed to the weather. Polyethylene has naturally excellent electrical, mechanical and cold weather capability, and with appropriate additives it can readily withstand ultraviolet rays from the sun. Polyethylene burns easily, but this can be altered by using additives where necessary. PVC POLYVINYLCHLORIDE PVC is a general purpose compound. It has reasonably good electrical, moisture resistance, flame retardant and cold temperature characteristics. It is only used on lower voltage wires, such as TW and NMWU cables. PVC can be modified to enhance various characteristics, but this usually results in degrading another feature, e.g. enhancing it for cold weather will degrade its high temperature and fire resistant characteristics. XLPE CROSS-LINKED POLYETHELENE XLPE is very widely used on wire and cable for direct burial; pulled into conduits, and on conductors in armoured power cables. It is also used on medium and high voltage cables. XLPE has excellent electrical and mechanical strength, it resists moisture and has good cold weather characteristics. It must have additives included to withstand ultraviolet rays if exposed to sunlight. XLPE insulation provides a first rate, reliable cable whether buried, pulled into conduit, laid submarine, or used as part of a bigger cable.
17 JACKETS CPE CHLORINATED POLYETHYLENE CPE has characteristics which are good for use on low voltage flexible cables (such as HPN cord) at lower cost than neoprene or hypalon. CPE is cold, oil and heat resistant, as well as flame retardant. In the case of HPN cord CPE acts as insulation and jacket combined. HYPALON HYPALON is a successor to Neoprene. It is flame retardant and is excellent where heat and oil are normally present such as on diesel-electric locomotives. Hypalon still has a role to play on specialized products, but has a limited market, as it has been displaced by CPE in many products. NEOPRENE NEOPRENE is a flame-retardant synthetic rubber. For many years it was a common jacketing material. Now largely superceded by other materials such as hypalon and CPE, Nexans no longer uses it. NYLON NYLON is applied as a thin film (like nail varnish) over insulations such as the PVC on T90. This allows the use of thinner insulation walls, and provides a slippery outer surface. This reduces insulation diameter and allows users to put more T90/TWN75 wires into a given conduit size, knowing that the tough nylon jacket will help avoid damage during installation. Nylon has poor UV resistance, and should not be exposed to sunlight. It is resistant to many common chemicals such as oils but it should NOT be used where acids are present. PE POLYETHYLENE PE provides an excellent, tough, water-resistant jacket. Polyethylene is highly recommended for cables that will be buried, put in underground ducts, or laid in water. Polyethylene does not have good flame resistance, and is not recommended in buildings. It is resistant to many common chemicals, such as acids, alkalis and some oils. PVC POLYVINYLCHLORIDE PVC used as a jacket is often modified to enhance physical characteristics such as low temperature flexibility and flame retardancy at the expense of electrical. It is tough, sunlight resistant, and can be compounded to meet the FT4 fire rating. It is resistant to many common chemicals such as acids, alkalis and most oils.
18 OVERHEAD CONDUCTORS ACSR ACSR ACSR Aluminum conductor, steel reinforced (ACSR) has long been the backbone of overhead transmission and distribution systems. It is common in all sizes from 6 AWG through 2000 kcmil, and can be even larger. It is made in a variety of constructions, depending on the conditions of use, but all constructions are characterized by the use of hard-drawn, aluminum alloy 1350 wires stranded over a galvanized steel wire core. Including a larger steel core can strengthen the conductor, thereby reducing the number of poles or towers required. ACSR-II ACSR-II is manufactured by twisting together two standard ACSR conductors with a very long and carefully controlled length of lay. This configuration helps reduce wind-induced conductor motion such as aeolian vibration and conductor galloping. The use of ACSR-II conductor can result in a lower installed cost system by reducing conductor fatigue damage, eliminating the need for vibration controlling accessories, reduced structure costs through higher installation tensions, and increased load capacity. SELF-DAMPING CONDUCTOR These conductors have layers of trapezoidal aluminum alloy 1350 or 6101 wires stranded over a galvanized steel wire core. A small gap is maintained between layers. As a result, the conductor dissipates the energy of wind-induced conductor motion. This conductor design has been used to good effect in the past, but Nexans Energy believes that the ACSR-II construction provides a more effective and economical way of controlling conductor motion. ACAR Aluminum conductor alloy reinforced (ACAR) is used where higher conductivity is required than is provided by ACSR. The construction consists of hard-drawn, aluminum alloy 1350 wires stranded over an aluminum alloy 6101 core. In addition to the higher conductivity, it helps reduce corrosion in situations where aluminum and steel might otherwise be affected. The initial purchase price is slightly higher than conventional ACSR. ASC Aluminum stranded conductor (ASC) consists only of hard-drawn, aluminum alloy 1350 wires stranded together. They are commonly used to exit power stations, and as sub-feeders in places where there are heavy loads, and short spans of metres. They provide good conductivity, are easy to handle, and are readily available. They do not have the same tensile strength as ACSR or ACAR.
19 OVERHEAD CONDUCTORS TIRE WIRE TIE WIRE Tie wire is used to attach overhead conductors to insulators. It is usually either 4 or 2 AWG soft solid aluminum wire. Softness is essential so that line crews can quickly and easily bend it into position around conductors and insulators. FIELD LASHED CABLE FIELD LASHED POWER CABLE Where space is restricted (e.g. along alleys, on poles carrying multiple circuits, or through heavily treed areas where rocky ground precludes burial) the use of XLPE-insulated, shielded and jacketed power cable can be a good choice. First a steel messenger is strung between poles, and then the cable is lashed to this with field spinning equipment. On short runs, the use of ultraviolet (UV) resistant tie-wraps (or equivalent) to attach the cable to the messenger may be satisfactory. Often cable already available in stores can be used for these installations, thereby reducing the need for purchasing special cable and special terminating materials. TREE CABLE SPACER CABLE AND TREE WIRE Spacer cable and tree wire are used for primary and secondary overhead distribution where limited space is available for rights-of-way. They are installed as an uninsulated conductor; however, the covering is effective in preventing direct shorts and instantaneous flashovers should tree limbs or other objects contact the conductors in such close proximity. Tree wire is used for spans where trees crowd the right-of-way, such as in wooded residential areas, when a minimum of interference with the environment is desired. The covering minimizes power outages due to conductor contact with tree limbs, reducing the need for frequent or severe trimming. Spacer cable is installed with other spacer cables on a supporting messenger through a series of spacers. The resulting close-proximity configuration minimizes the amount of space and hardware required for line installation; it is particularly useful in congested areas.
20 OVERHEAD & SECONDARY SERVICE CABLES NS75/NS Volts TYPES NS75 AND NS90 NEUTRAL SUPPORTED CABLE (600 VOLTS) TYPES NS75 FT1 AND NS90 FT1 NEUTRAL SUPPORTED CABLE (600 VOLTS) Nexans neutral supported cables consist of an assembly of one, two, or three insulated phase conductors and an optional insulated control/supply conductor factory-cabled around a neutral conductor. The neutral conductor is the supporting member. The conductors are insulated with polyethylene (PE) rated 75 C or cross-linked polyethylene (XLPE) rated 90 C. They are intended for use either as a service drop cable between a power pole and the service entrance, or as a secondary distribution cable between poles. Their use should be limited to circuits not exceeding 600 volts phase-to-phase. Duplex and triplex service drop cables are intended to deliver single-phase power from the secondary power line or pole-mounted transformer to the service entrance conductors at the user s building or other structure. Quadruplex service drop cable is intended to deliver three-phase power from the secondary power line or pole-mounted transformer to the service entrance conductors at the user s building or other structure. The phase conductors are aluminum alloy 1350-H19 hard-drawn, compact concentric-lay stranded #6 AWG to 500 kcmil in size. NS75/NS90 FT1 600 Volts The standard neutral conductor is aluminum conductor steel reinforced (ACSR) for use with aluminum phase conductors. The former types NS-1and NSF-2 are no longer applicable. New type designations NS75 and NS90 now reflect the temperature ratings. For NS75 cables, the standard insulation on the phase conductor(s) is black linear low-density polyethylene (LLDPE) insulation with a 75 C temperature rating. For NS90 cables, the standard insulation on the phase conductor(s) is black low-density polyethylene (XLPE) insulation with a 90 C temperature rating. Cables supplied with an optional flame retardant PVC jacket extruded over the insulation are designated NS75 FT1 or NS90 FT1 as applicable. TRANFORMER DROP WIRE TRANSFORMER DROP WIRE Transformer drop wire consists of a stranded soft bare copper conductor covered with black linear low-density polyethylene (LLDPE). It is used to connect the transformer to the primary supply line.
21 OVERHEAD & SECONDARY SERVICE CABLES LINE WIRE LINE WIRE Line wire is intended for use in overhead distribution circuits operating at primary or secondary voltages. The covering provides circuit protection against momentary contact with other conductors or trees. Because the covering carries no voltage rating, the conductors must be installed on insulators adequate for the intended service voltage. The user should consider the dielectric compatibility of the covering, insulator and conductor/insulator tie. Typically medium-density polyethylene (MDPE) insulation is applied over an aluminum alloy 1350, ACSR or medium hard-drawn copper phase conductor. FIELD SPUN SECONDARY CABLE FIELD SPUN SECONDARY CABLE Similar to line wire, this cable has a heavier covering of medium density polyethylene (MDPE) and 600 V rating. It is supplied as single conductors which are pulled together during installation. It is lashed to a field-installed messenger using a spinning machine, or in short runs, with suitable clips or straps. It occupies less space on the pole than line wire, and if brought down by storm or accident, offers greater protection to passersby. STREETLIGHT WIRE SLV SLV (Streetlight Wire) This cable consists of two solid copper conductors, RW90 insulated, laid parallel with a black, low temperature PVC jacket. It is designed to run from the base of hollow street light poles to the bracket and from there to the lamp holder. CSA approved as type RW90. Approval number LL
22 POWER CABLE 5 kv TO 46 kv MEDIUM VOLTAGE POWER CABLE (5-46 kv) BASIC CONSTRUCTION Conductors may be either aluminum or copper. They are usually stranded, but sizes 2/0 AWG and smaller are often supplied as solid. A thin layer of semiconducting crosslinked polyolefin (XLPO) is extruded over the conductor, followed by the tree-retardant crosslinked polyethylene (TR-XLPE) insulation and then a strippable semiconducting crosslinked polyolefin (XLPO) insulation shield. All three layers are extruded through a single true triple crosshead on a dry cure catenary continuous vulcanization (CCV) line. Depending on the cable's application, it may have metallic shielding, armour or sheath and an overall jacket. Such cables can be directly buried, pulled into underground ducts, submerged under water or hung from an overhead messenger wire. They are robust, easy to install and readily available in most conductor sizes and voltages from 5 to 46 kv. CONDUCTOR Conductors are made from either aluminum alloy 1350 or soft bare copper, and can be solid, compressed stranded or compact stranded. Stranded conductors can be manufactured with Strandblock, which prevents the ingress of water into the conductor and retards the development and propagation of electrochemical (water) trees in the insulation. CONDUCTOR SHIELD Premature cable failure can also be initiated by microscopic irregularities at the interface between the conductor shield layer and the insulation. The use of an optional supersmooth conductor shield compound provides a smooth, uniform interface between these layers. This reduction of interface irregularities and protrusions helps reduce the risk of cable failure. EXTRA CLEAN TR-XLPE INSULATING COMPOUND All primary distribution cables are manufactured with a tree-retardant crosslinked polyethylene (TR-XLPE) compound containing an additive to retard the development and propagation of water trees. Water trees in the insulation can also be triggered by the presence of contaminants in the insulation. All power cables supplied by Nexans Energy are manufactured with extra-clean compound that has been packaged, shipped and unloaded under "clean room" conditions. It is then conveyed to the extruder by a sealed vacuum system. In this way the compound is never exposed to possible air-borne contaminants. Insulation level comes from ICEA standards and relates to the fault clearing time for the system on which the cable is used. 100% (Grounded) level is used where a system fault is cleared within 1 minute. 133% (Ungrounded) level is used where a system fault is cleared within 1 hour. (133% is often specified when extra protection against surges, lighting, or water treeing is desired.
23 POWER CABLE 5 kv TO 46 kv CONCENTRIC NEUTRAL CABLE (5-46 kv) METALLIC SHIELDING Concentric Neutral The concentric neutral wires may be either bare or tinned copper. For single-phase systems, the conductance of the neutral is equivalent to that of the phase conductor. For three-phase systems, it is typically 1/3 but can be made with 1/6, 1/12, etc. neutrals. The concentric wires serve to carry the neutral return current as well as the ground fault current. SHIELDED POWER CABLE (5-46 kv) Helical Tape For electrostatic shielding of the underlying cable core, one or more copper tapes are applied helically over the extruded insulation shield. It may not always have sufficient fault current capability for protective relaying purposes. CORU-SHIELD (5-46 kv) CORU-SHIELD Another option consists of a longitudinally applied corrugated copper tape (with a small overlap) along the axis of the cable. This offers greater short circuit capability than helically applied tapes and reduced shield loss when compared to the concentric neutral construction. The sealed overlap of the shield provides increased resistance to radial moisture ingress. JACKET The jacket provides mechanical protection during installation and inhibits corrosion of the concentric neutral wires or metallic shield. The standard jacket on concentric neutral cables is an extruded-to-fill (encapsulating) linear low-density polyethylene (LLDPE). It prevents longitudinal ingress of water between the concentric neutral wires if the jacket is damaged. On request medium-density polyethylene (MDPE) or semiconducting polyethylene can also be used. The jacket can also be of the overlaying (sleeved) type using any of the above materials as well as PVC. If fire is a concern (as in a building), a PVC jacket should be used. It is not quite as tough as polyethylene, but has superior flame retardance. Where required for identification of power cables in shared underground systems, three extruded red stripes can be provided on the cable jacket. CABLE IN CONDUIT Cable in Conduit Cable in Conduit is an extruded high-density or medium density polyethylene duct over primary cable. The conduit provides additional mechanical protection for the cable, reduces installation time, and allows for quick access and ease of cable replacement. Specifically used for primary cables, cable in conduit is also available for secondary cable.
24 UNDERGROUND SECONDARY & SERVICE CABLE USEI75/ USC Volts LLDPE-PVC TYPE USE175 UNDERGROUND SERVICE ENTRANCE CABLE This is the most widely used cable for underground secondary distribution and service entrance applications at 600 volts or less. They may be either directly buried or installed in ducts. Type USEI75 is principally used for underground power supply to houses and trailer parks. It is economical and readily available from stock in many sizes. The aluminum alloy 1350 phase conductors are insulated with black polyethylene (LLDPE). Each phase conductor has a colour-coded, flame retardant PVC jacket applied over the insulation prior to being cabled together. USEI Volts XLPE-PVC TYPE USEI90 UNDERGROUND SERVICE ENTRANCE CABLE This is the most widely used cable for underground secondary distribution and service entrance applications at 600 volts or less. They may be either directly buried or installed in ducts. Type USEI90 is principally used for underground power supply to houses and trailer parks. It is economical and readily available from stock in many sizes. The aluminum alloy 1350 phase conductors are insulated with black crosslinked polyethylene (XLPE). Each phase conductor has a colour-coded, flame retardant PVC jacket applied over the insulation prior to being cabled together. USEB Volts TYPE USEB90 UNDERGROUND SERVICE ENTRANCE CABLE Used for the same purposes as USEI-90, however, there are differences in the cable construction. The conductors and insulation are the same (i.e. aluminum conductors with XLPE), but instead of a jacket on each conductor, the conductors are cabled together and a copper concentric neutral is applied. The entire assembly is then covered with an overall PVC jacket. This provides a robust cable, which is better able to withstand frost heaving, rodents' teeth, and minor dig-ins. CATHODIC PROTECTION CABLE CATHODIC PROTECTION CABLE Buried alongside pipelines, storage tanks, and other structures, this cable supplies DC power to cathodic protection systems. Made of stranded copper conductor, insulated with medium density polyethylene, they are made in various sizes and colours as required.
25 UNDERGROUND SECONDARY & SERVICE CABLE TRACER WIRE TRACER WIRE Tracer wires are small polyethylene or PVC-covered copper wires (usually 14 or 16 AWG) which are buried beside pipelines or utilities to make them easier to locate in the future. Location is by the use of various electronic techniques. TYPE RWU Volts TYPE RWU90 (1000 VOLT) Type RWU90 cable is made with either copper or aluminum conductors insulated with a thick covering of crosslinked polyethylene (XLPE). It has excellent water resistance, can be handled in cold temperatures, and is mechanically and electrically strong. It can be directly buried in the earth or pulled into ducts. TWU Volts TWU-40 (600 VOLT) Type TWU-40 cable is made with copper conductors having a thick PVC plastic insulation. It is designed for direct burial and can provide good service at an economical price in conditions that are not too severe.
26 w w w. n e x a n s. c o m 140 Allstate Parkway, Markham, Ontario L3R 0Z7 Tel: (905) Fax: (905)
LEAD FREE FIREX. Interlock Armored Cables TECK90 and MC Industrial Cables. w w w. n e x a n s e n e r g y. c o m
FIREX Interlock Armored Cables TECK90 and MC Industrial Cables LEAD FREE O V E R 1 8 0 Y E A R S O F E X P E R I E N C E 866-663-9267 w w w. n e x a n s e n e r g y. c o m Interlock Armored Cables Introduction....2
IEEE POWER ENGINEERING SOCIETY CHICAGO CHAPTER THE OKONITE COMPANY WEDNESDAY JANUARY 11, 2006 JIM FITZGERALD ENGINEERING LINGO
IEEE POWER ENGINEERING SOCIETY CHICAGO CHAPTER THE OKONITE COMPANY WEDNESDAY JANUARY 11, 2006 JIM FITZGERALD ENGINEERING LINGO WHEN YOU HEAR AN ENGINEER SAY A NUMBER OF DIFFERENT APPROACHES ARE BEING IMPLEMENTED
Corporate Profile ROYAL. MODERN ROYAL ELECTRIC Ideal Power Solution MRE ELECTRICAL, INSTRUMENTATION & COMMUNICATION SYSTEMS
Corporate Profile MODERN ROYAL ELECTRIC Ideal Power Solution ROYAL MRE ELECTRICAL, INSTRUMENTATION & COMMUNICATION SYSTEMS MAJOR STOCKIST >>> CATHODIC PROTECTION CABLES >>> LOW VOLTAGE CABLES >>> MEDIUM
The National Armored Cable Manufacturers Association Presents. Installation Standard for Types AC and MC Cables
The National Armored Cable Manufacturers Association Presents Installation Standard for Types AC and MC Cables An ANSI Standard Original document jointly produced by NECA and NACMA as Standard for Installing
W-2. Stranding Comparison
Wire Knowledge W-1 W-2 Stranding Comparison Conductor Coatings/Coverings PURPOSE To facilitate stripping of components applied over the conductor To prevent compound fall-in Improve solderability Prevent
Industrial Cable Solutions for Variable Frequency Drives
Industrial Cable Solutions for Variable Frequency Drives Tough challenges call for innovative solutions, and General Cable is your worldwide source for new products and a wide range of industry-leading
ScottishPower Distribution Cables & Equipment. Metal Theft
ScottishPower Distribution Cables & Equipment Metal Theft April 2012 As an aid to deterring to metal theft this booklet has been put together to help identify the types of utility power cables and associated
Fault location on power cables. Fault location on power cables
Fault location on power cables Fault location on power cables Contents: 1. Introduction 2. Construction of power cables 3. Cable faults 01. Introduction Fault location on communication and power cables
WHITE PAPER Fire & safety performance standards
WHITE PAPER Fire & safety performance standards Terminologies describing Fire Performance Terminologies describing Fire Performance often present a challenge to understand as how they apply to a cable
Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, 2016. Underground branch circuit feeding a detached garage:
Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, 2016 * Garage construction requires permits (electrical, building) * Permits must be applied for at the time. * Dial
KNOW YOUR OPTIONS: 230 KV POWER CABLES
KNOW YOUR OPTIONS: 230 KV POWER CABLES 71 CONDUCTOR MATERIAL AND SIZE Conductor material is a matter of both customer preference and required current carrying capacity At 230 kv, copper is most common
CIR. Index. Gexol. Standard CIR UL Listed Type TC-ER. Crush and Impact Resistant Without External Armoring. Arctic CIR UL Listed Type TC-ER-HL*
Gexol CIR Crush and Impact Resistant Without External Armoring Passes the same stringent crush and impact testing required by UL 2225 for Type MC-HL n Available in Standard and Arctic Grade Jackets n Highly
100% EMI Emission Containment
100% EMI Emission Containment Designed for Longer Service Life Highly Flexible for Easier Handling and Faster Installation Authorized Distributor Industrial VFD Cables Index n Variable Frequency Drive
TS 813 GROUNDING AND BONDING TTD 813.001 TRAFFIC SIGNAL INSTALLATION AND CONTROLLER CABINET GROUNDING SYSTEM TTD 813.005 CONTROLLER CABINET GROUNDING
TORONTO TRANSPORTATION January 2012 TS 813 GROUNDING AND BONDING TABLE OF CONTENTS 1. DRAWINGS TTD 813.001 TRAFFIC SIGNAL INSTALLATION AND CONTROLLER CABINET GROUNDING SYSTEM TTD 813.005 CONTROLLER CABINET
KNOW YOUR OPTIONS: 69 KV XLPE POWER CABLE
Know Your Options: 69 kv XLPE Power Cable 3 material and size material is a matter of both customer preference and required current carrying capacity Copper conductor common for larger loads When both
Section 5 161 kv Power Cables
Know Your Options: 161 kv Power Cable 61 material and size material is a matter of both customer preference and required current carrying capacity Copper conductor common for larger loads When both copper
Cable Selection for Medium Voltage Capacitor Banks and Harmonic Filter Banks
Cable Selection for Medium Voltage Capacitor Banks and Harmonic Filter Banks Introduction This document presents the fundamental aspects of cable and conductor selection for connecting pad mounted shunt
Network Standard Advice No. 1420C 9/6/2011
Network Standard Advice No. 1420C 9/6/2011 TO: Customers, Service Providers and Ausgrid Staff. Advisory Note on Changes to the Use of 11kV Cable Types. Introduction This Network Standard Advice (NSA) provides
Hook-Up and Lead Wire
3.1 Hook-Up and Lead Wire 3 Table of Contents Hook-Up & Lead Wire Page Introduction: UL Style & CSA Type Listings 3.2 PVC 3.3 3.8 300V, 80 C 3.3 300V, 105 C 3.4 600V, 105 C 3.5 (Type MW) MIL-W-76C-PVC:
Unarmored Variable Frequency Drive (VFD) Cable Termination Guide
Authorized Distributor Unarmored Variable Frequency Drive (VFD) Cable Termination Guide Be Certain with Belden A Step-by-Step Look at the Connection/Termination of Unarmored VFD Cables Terminating Unarmored
Instrumentation Cable...14-17. Power Cable...2-11. Assembly Solutions...32
Severe Cold Durability Exceeds CSA Cold Bend / Cold Impact (-0 C/-35 C) Drilling Mud Resistant Flame Retardant Certified to IEC 9-3 (33-3A) and IEEE 580 Oil Resistant Assemblies...3-33 Ester Based Mud
800 Communications Circuits
ARTICLE 800 Communications Circuits INTRODUCTION TO ARTICLE 800 COMMUNICATIONS CIRCUITS This article has its roots in telephone technology. Consequently, it addresses telephone and related systems that
Outside Telephone Cable
Outside Telephone Cable Filled Core. Moisture Barrier. Description Soft copper wires insulated with high density polyethylene, foam skin or solid. Filled core, conformed by groups of pairs or by unit of
ELEVATOR TRAVELING CABLE - DESIGN EVOLUTION
ELEVATOR TRAVELING CABLE - DESIGN EVOLUTION by Richard Laney Introduction Elevator traveling cable is a vital link between the elevator car and controller. In conventional elevators, all power and signal
2012 CATALOG AEROSPACE VVIRE & CABLE INC. aerospacewire.com
* 2012 CATALOG AEROSPACE VVIRE & CABLE INC. A VV aerospacewire.com W e p r o u d l y m a n u f a c t u r e h i - t e m p w i r e & c a b l e. PLENUM CABLE. INDUSTRIAL CABLE. TRAY CABLE. MILITARY WIRE.
Fire Performance Standard
Fire Performance Standard At present, in cable industry, Fire Retardant, Low Smoke Halogen Free (LSZH), Low Smoke Fume (LSF) and Fire Resistant cables are all described as Fire survival Cables. Flame Retardant
Arbiter Systems Test Leads: Engineered for Optimum Performance and Safety
Arbiter Systems Test Leads: Engineered for Optimum Performance and Safety Arbiter Systems, Inc. test equipment offers outstanding performance, flexibility, and value. Our test leads offer nothing less.
SECTION 18370 SIGNAL WIRE AND CABLE
SECTION 18370 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for all cable and wire required for signal and signal power system wiring to wayside shelters, junction boxes, and factory
Electrical Grounding. Appendix C
Appendix C Electrical Grounding Low-Voltage Equipment Grounding The most frequently cited Office of Safety and Health Administration (OSHA) electrical violation is improper occupational grounding of equipment
2 8 k V, 1 / C, T R X L P E I N S U L A T E D, F L A T S T R A P S H I E L D E D C A B L E, C O M P R E S S E D S T R A N D I N G
Seattle Cit y Light 1 of 4 2 8 k V, 1 / C, T R X L P E I N S U L A T E D, F L A T S T R A P S H I E L D E D C A B L E, C O M P R E S S E D S T R A N D I N G 1. Scope This standard covers the detailed requirements
AWG: Cat5e: Cat6: Cat6A:
Some of the terms used in the cable business can be vexing to even the most seasoned folks in the industry. If any of this terminology has ever made you scratch your head, you are certainly not alone.
Contact Hueson Corporation for additional information or details. http://www.huesonwire.com 38 Sutton Street Northbridge, MA 01534 508-234-6372
Hueson Corporation of Northbridge MA, a specialty wire and cable manufacturer has recently introduced a solution to a long term industry challenge in the Trailer Cable Industry. Their solution involves
RoHS DATA, COAXIAL AND ELECTRONIC M.R. D A TA, C O A X I A L, ECOLGICAL Telecom Cables A N D EL E CTRON I C. Cables
RoHS DATA, COAXIAL AND ELECTRONIC D A TA, C O A X I A L, A N D EL E CTRON I C Cables Index SOLID MULTI-CONDUCTOR CABLES STRANDED MULTI-CONDUCTOR CABLES SPEAKER/ZIP WIRE THERMOSTAT CABLE FIRE ALARM CABLE
UGVCL/SP/591/11KV HT AB CABLE
TECHNICAL SPECIFICATION FOR 11KV AERIAL BUNCHED CABLES FOR OVERHEAD LINES (CROSSED LINKED POLYTHENE DRY GAS CURED) 1. SCOPE This specification covers requirements of XLPE insulated, 11 KV Aerial Bunched
Gexol. Gexol. The Global Cable Solutions Company. Designed for safe, reliable performance in the harshest oil and gas operating environments
Gexol Gexol World Class World Class Designed for safe, reliable performance in the harshest oil and gas operating environments Power Control Instrument VFD The Global Cable Solutions Company Gexol World
3.6/6 kv XLPE insulated cables 5. 6/10 kv XLPE insulated cables 15. 8.7/15 kv XLPE insulated cables 25. 12/20 kv XLPE insulated cables 35
CONTENTS INTRODUCTION 1 Cable selection, cable specification, cable services CABLES Constructional data: 3.6/6 kv XLPE insulated cables 5 SECTION 1 6/10 kv XLPE insulated cables 15 SECTION 2 8.7/15 kv
Aerial Fibre Optics. Complete One Stop Solution for Aerial Fibre Optics. OPGW Cable and Fittings for OPGW
Complete One Stop Solution for OPGW Cable and Fittings for OPGW 53, Justice Chandra Madhav Road, Kolkata - 700020. India. Phone: 91-33-24748575 / 7565 Fax: 91-33-2476-1955 Email: [email protected] Website:
WIRE, TERMINAL AND CONNECTOR REPAIR CONDUCTORS
CONDUCTORS Conductors are needed to complete the path for electrical current to flow from the power source to the working devices and back to the power source. Special wiring is needed for battery cables
APPLICATION ORIENTED DESIGN OF CABLES
APPLICATION ORIENTED DESIGN OF CABLES Mrs. Rohini Bhattacharyya, Dubai cables Ltd.P. O. Box 11529,Dubai. [email protected] Mr. Nawaf Ahmad Al Mohaideb Dubai Cables Ltd. P. O. Box 11529, Dubai. [email protected]
HINDUSTAN PETROLEUM CORPORATION LIMITED ENGINEERING & PROJECTS GRESHAM ASSURANCE HOUSE, 2 ND FLOOR, A-1595(3) 1-A, SIR P M ROAD, FORT MUMBAI-400 001
NEW POL DEPOT AT HINDUSTAN PETROLEUM CORPORATION LIMITED ENGINEERING & S GRESHAM ASSURANCE HOUSE, 2 ND FLOOR, A-1595(3) 1-A, SIR P M ROAD, FORT MUMBAI-400 001 TECHNICAL SPECIFICATION OF XLPE, FRLS LT CABLES
Basic Cable Assemblies DELIVERING QUALITY SINCE 1952.
Basic Cable Assemblies DELIVERING QUALITY SINCE 1952. Cable Types Cable Types Hook-up & Lead Wire Most Basic 2 Cable Types Cable Types Twisted Pair Cable A type of cable that consists of two independently
A quick product finder for commercial applications JUDD WIRE INC. A member of the Sumitomo Electric Industries group of companies
A quick product finder for commercial applications JUDD WIRE INC. A member of the Sumitomo Electric Industries group of companies Select, Customize, Order & Receive Products with Ease This catalog contains
MEDIUM VOLTAGE POWER CABLES
MEDIUM VOLTAGE POWER CABLES CONTENTS 1 GENERAL INTRODUCTION 4 TECHNICAL INFORMATION 15 25 35 45 Single Core XLPE Insulated PVC Sheathed Cables UNARMOURED CABLES COPPER UNARMOURED CABLES ALUMINUM ALUMINUM
4 Installation Requirements
4 Installation Requirements 9 4.1 Code Reference The authority having jurisdiction should be referenced to determine what law, ordinance or code shall apply in the use of flexible duct. Ducts conforming
Unified requirements for systems with voltages above 1 kv up to 15 kv
(1991) (Rev.1 May 2001) (Rev.2 July 2003) (Rev.3 Feb 2015) Unified requirements for systems with voltages above 1 kv up to 15 kv 1. General 1.1 Field of application The following requirements apply to
All Wires and Cables Are Not Created Equal
All Wires and Cables Are Not Created Equal When comparing life cycle costs for wires and cables in wind systems, consider the specific applications, cost per failure and dielectric losses to determine
Session 14 Cable Support Systems
Session 14 Cable Support Systems Cable Support Systems in the IEC World A new IEC Standard, IEC61537 2001 has been developed If full details of the cabling layout are available then the likely cable load
Generator DoCKInG StatIonS
Generator DOCKING STATIONS TRYSTAR Portable Power Cable Cam to cam cable extensions 2000V, 100A-400A rated to NEC table 400.5 (B) All portable power cable sold is highly flexible and UL & C-UL or CSA Listed
Solar Power Solutions
Solar Power Solutions Wire and Cable Photovoltaic Connectors Combiner Boxes Fuses Grounding Power Connectors Physical Support Products Cable Ties Supply Chain Solutions Products. Technology. Services.
CONTENTS. Yale University Design Standards. Underground Electrical Duct Bank. A. Summary. B. System Design and Performance Requirements
16600 Underground Electrical Duct Bank This document provides design standards only, and is not intended for use, in whole or in part, as a specification. Do not copy this information verbatim in specifications
CONSTRUCTION STANDARD ELECTRIC OPERATIONS ORGANIZATION
Page 1 of 11 ****This Standard Supercedes BECo CS2.13-2.3 & ComElectric OH Construction Manual, System Grounding Section, drawings CGND, GRDSUM, and C2**** 1.0 Bill of Materials GROUNDING AND BONDING POLE-MOUNTED
)454, !,5-).)5- #!",% 3(%!4(3 #/.3425#4)/. ).34!,,!4)/.!.$ 02/4%#4)/. /& #!",%3!.$ /4(%2 %,%-%.43 /& /543)$% 0,!.43. )454 Recommendation,
INTERNATIONAL TELECOMMUNICATION UNION )454, TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU #/.3425#4)/. ).34!,,!4)/.!.$ 02/4%#4)/. /& #!",%3!.$ /4(%2 %,%-%.43 /& /543)$% 0,!.43!,5-).)5- #!",% 3(%!4(3
HIGH- AND EXTRA-HIGH-VOLTAGE GLOBAL CABLE SYSTEM SOLUTIONS Rely On Our Experience... Experience Our Capabilities
HIGH- AND EXTRA-HIGH-VOLTAGE GLOBAL CABLE SYSTEM SOLUTIONS Rely On Our Experience... Experience Our Capabilities RELY ON OUR EXPERIENCE... EXPERIENCE OUR CAPABILITIES For close to half a century, Silec
INTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 60502-1 Second edition 2004-04 Power cables with extruded insulation and their accessories for rated voltages from 1 kv (U m = 1,2 kv) up to 30 kv (U m = 36 kv) Part 1: Cables
VIPERFLEX ELECTRIC CABLE
VIPERFLEX Flexible Low Voltage Electric Cable - 0.6/1kV (Rubber insulated) H07 RN-F & H07 BN-F Single Core 2-Core 2-Core and Earth 3-Core and Earth 4-Core and Earth Multi-Core and Earth H07 RCN-F & H07
PROFIBUS cable. for PROFIBUS-PA and -DP 10/63-6.46 EN
for PROFIBUS-PA and -DP 10/63-6.46 EN CPN 080/CPE 080-Ex PROFIBUS-PA basis cable AWG 18, 0.88 mm 2 Use For fixed installation indoor and outdoor, on racks and in conduits. Application Fieldbus cable for
Exane 125 Drilling Rig and Commercial Marine Cable
Exane 125 Drilling Rig and Commercial Marine Cable Over 20 Years of Superior Perfomance On Oil Rigs Around The World Engineered Wire & Cable for Demanding Applications Certified as Type P per IEEE-45 STD
Presenters Brett Weiss, Gabe Martinez, Brian Kroeger.
1 Presenters Brett Weiss, Gabe Martinez, Brian Kroeger. Topics to be covered: Cable identification Purpose of the various cable types Installation techniques Building Infrastructure Overview of networking
Flexible and safe solutions, for decades. Cables for alarmand safety systems
Flexible and safe solutions, for decades. Cables for alarmand safety systems 2 We offer the widest range of cables on the market for every kind of installation. It s all about reliability. It is always
The Instrumentation Cable Experts
1 The Instrumentation Cable Experts Facilities Head office & factory 1300 Industrial Boulevard Mt Pleasant, Texas 75455, USA www.dekoroncable.com Stocking Centres USA Mt Pleasant and Houston Singapore
International Electrotechnical Commission Standards
International Electrotechnical Commission Standards Standard IEC 60028 IEC 60038 IEC 60050-461 IEC 60055-1 IEC 60055-2 IEC 60092-101 IEC 60092-350 IEC 60092-351 IEC 60092-352 IEC 60092-353 IEC 60092-354
CABLE 101. The Basics of Wire & Cable. Copyright 2007, Belden Inc.
CABLE 101 The Basics of Wire & Cable Copyright 2007, Belden Inc. KEY TERMS Insulations Jacket Capacitance Attenuation Velocity of propagation Dielectric strength Dielectric constant Working voltage Elongation
www.klmtechgroup.com TABLE OF CONTENT
Page : 1 of 13 Project Engineering Standard www.klmtechgroup.com KLM Technology #03-12 Block Aronia, Jalan Sri Perkasa 2 Taman Tampoi Utama 81200 Johor Bahru Malaysia ELECTIRAL GROUNDING TABLE OF CONTENT
Cables, Cable Laying & Accessories Manual
Distribution Business Cables, Cable Laying & Accessories Manual Database ref: File Ref: Title Page & Revision Log For Cables & Access v4 - Nov 2003.doc Manual Name: Cables & Accessories Manual Version
Section 21. Telecommunication Hardware. www.geindustrial.com BuyLog Catalog 21-1
Introduction...21-1 Fiber Closure Hardware...21-2 Cable Location Surge Protectors...21-4 Introduction GE has been manufacturing Telecommunication Hardware products for over 20 years and has become a leader
TELE-FONIKA CABLE AMERICAS
TELE-FONIKA CABLE AMERICAS TELE-FONIKA CABLE AMERICAS (TF KABLE) is a US firm with corporate offices and main facility located in Bolingbrook, IL and is a wholly owned subsidiary of Tele-Fonika Kable SA.
GUIDELINES FOR UTILITY INSTALLATIONS Part 1 - Wire Lines and Communications Cables
Engineering Department SEPTEMBER, 2007 GUIDELINES FOR UTILITY INSTALLATIONS Part 1 - Wire Lines and Communications Cables General Requirements This section applies to all public and private utilities,
Your Only Solution for All Variable Frequency Drive Applications
ASD/VFD Cable System ASDBrochure.indd 1 Your Only Solution for All Variable Frequency Drive Applications 11/2/12 9:23 AM Inadequacies in Standard VFD Cables: EMC-Electro Magnetic Compatibility Electromagnetic
WHY CABLE TRAY? BECAUSE A CABLE TRAY WIRING SYSTEM PROVIDES SAFE AND DEPENDABLE WAYS TO SAVE NOW AND LATER
Large numbers of electrical engineers have limited detail knowledge concerning wiring systems. There is the tendency by engineers to avoid becoming involved in the details of wiring systems, leaving the
CONFLEX ELECTRIC CABLE
CONFLEX ELECTRIC CABLE CONFLEX - 0.6/1kV Flexible VSD/EMC Cables Applications WW VSD/EMC cables are manufactured for use where electrical interference distorts signal transmission in electric motors. Standard
RAUFOSS EXPLOSIVE COMPRESSION FITTINGS
INSTRUCTION MANUAL FOR RAUFOSS EXPLOSIVE COMPRESSION FITTINGS Box 7 2831 Raufoss Norway Tlf.: +47 61 15 17 87 Fax: +47 61 15 25 56 25 January 2013, rev 2 Available on www.vpmetall.no Page 1 CONTENTS GENERAL
2012 Electrical Code Changes Module 2 Sections 6-16
2012 Electrical Code Changes Module 2 Sections 6-16 ETEL-11(02)-00 (2012-03-26) Table of Contents Section 6 Services and Service Equipment... 2 Section 8 Circuit Loading and Demand Factors... 6 Section
SYSTEM 1850-SE SERVICE ENTRANCE CABLE SYSTEM
Pyrotenax SYSTEM 1850-SE SERVICE ENTRANCE CABLE SYSTEM Contents Introduction This section provides an overview of general circuit design considerations and installation guidelines for a Pyrotenax System
Session Five: Modern XLPE Materials for Extruded Energy Cable Systems
Session Five: Modern XLPE Materials for Extruded Energy Cable Systems Abstract Hakan Lennartsson Senior Technical Service Manager, Borouge Hong Kong Pte. Ltd. The first medium voltage cables using extruded
Two different types of cables are used in primary airfield lighting circuits: - unshielded cables and - shielded cables
Two different types of cables are used in primary airfield lighting circuits: - unshielded cables and - shielded cables Classically both cables have a single AWG 8 copper conductor or a cross section of
Cable Products HONEYWELL SECURITY & CUSTOM ELECTRONICS. Honeywell's Genesis Series provides a full range
HONEYWELL SECURITY & CUSTOM ELECTRONICS Cable Products Honeywell's Genesis Series provides a full range of low voltage cables for security, fire, sound, voice and data, video, structured cabling and other
3M Scotchcast Mine and Portable Cable Splice Kit 8096-4
3M Scotchcast Mine and Portable Cable Splice Kit 8096-4 Installation Instructions 1.0 Kit Contents: 2 Funnels 3 EPDM Rubber Cold Shrink Cold Shrink Insulator 1 Wrap-around Mold Assemblies 2 Rubber Mold
DIVISION 26 - ELECTRICAL SECTION 26 05 20 CABLES FOR INSTRUMENTATION
DIVISION 26 - ELECTRICAL PART 1 - GENERAL 1.01 SUMMARY A. Section Includes 1. Instrumentation Cables 1.02 SUBMITTALS A. Submit in accordance with requirements of Section 01 33 00. B. Product Data: Submit
2011/2008/2005 NATIONAL ELECTRICAL CODE SOLAR PV CODE COMPLIANCE REFERENCE
2011/2008/2005 NATIONAL ELECTRICAL CODE SOLAR PV CODE COMPLIANCE REFERENCE PAGE 1 OF 5 This Reference provides a very comprehensive list of aspects of a solar PV installation that could be reviewed, clarifying
DIRECTCONNECT SERVICE
DIRECTCONNECT SERVICE PRE-ASSEMBLED: LEADS, GROUNDS AND STINGERS/WHIPS Save Time, Labor and Money Lead Stinger/Whip Stock Colors (Blue, Green, Red, Yellow) available Stocked genuine Lenco and Tweco Connectors
Screened cable and data cable segregation
December 2007 Screened cable and data cable segregation Can an armoured power cable be considered a screened cable and how does this relate to power and data cable segregation? The short answer is yes;
RE-ENTERABLE SPLICE CLOSURE KITS. (For Air Core None Pressurized Cable)
Triple T Broadband Public Co., Ltd. Outside Plant Standard Sector Specification No. OES-001-027-04 Issued: RE-ENTERABLE SPLICE CLOSURE KITS (For Air Core None Pressurized Cable) 1. SCOPE 1.1. This specification
Specializing in the cable business for over 38 years, PT. SUPREME CABLE
Specializing in the cable business for over 38 years, PT. SUPREME CABLE MANUFACTURING & COMMERCE Tbk. (PT. SUCACO Tbk) has grown steadly to become a largest and leading cable manufacturer, with international
Trial Exams C. Standards and Regulations. Examination No: GH-08-C- 1 hour and 5 minutes plus 10 minutes reading time
Trial Exams C Standards and Regulations Examination No: GH-08-C- This test is intended to gauge your knowledge of essential information contained within AS/CA S009:2013. To qualify for an allpication to
Quality Reliability Innovation. ISO 9001 : 2000 CERTIFIED BY AFAQ No. QUAL / 1997 / 7034 a COPPER TELECOMMUNICATION CABLES
Quality Reliability Innovation ISO : CERTIFIED BY AFAQ No. QUAL / 7 / 7 a COPPER TELECOMMUNICATION CABLES COPPER TELECOMMUNICATION CABLES CONTENTS 7 NOTICE INTRODUCTION QUALITY ASSURANCE RECOMMENDED ORDERING
Flexible cables for submersible products
Flexible cables for submersible products Standards SUBCAB cables complies with the following general standards: IEC 6045 (general) IEC 608 class 5 (conductor) IEC 608-- CLAUSE 9 (oil resistant) IEC 608--
USA: 866.LAWSON4U (866.529.7664) Canada: 800.563.1717 lawsonproducts.com. Electrical Industrial and Fleet Solutions
USA: 866.LAWSON4U (866.529.7664) Canada: 800.563.1717 lawsonproducts.com Electrical Industrial and Fleet Solutions Lawson's ELECTRICAL SOLUTIONS Electrical Wire Low voltage (60V) and high voltage (300/600V)
Roofing Systems. There are many different systems, each with it's own special requirements and benefits. Browse through all the options below.
Roofing Systems There are many different systems, each with it's own special requirements and benefits. Browse through all the options below. BUR (Built-Up Roofing) Built-Up-Roofing, BUR is a roof that
T A B L E T 1 T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A
T A B L E T 1 1 of 7 Tests & Inspection Cable PCUT & PCUT-A (Table T1) T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A No. Test Scale MOC Requirements G 20:10:001:01 Defined Test
SUBJECT: NO MORE 300 VOLTS IN PLTC PRINT LEGEND
Belden Electronics Division P.O. Box 1980 Richmond, Indiana 47375-1980 2200 U.S. Highway 27 South Richmond, Indiana 47374-7279 Telephone: 765 983 5200 Facsimile: 765 983 5825 SUBJECT: NO MORE 300 VOLTS
Comparative study for cables and busbars
Comparative study for cables and busbars Preliminary considerations To compare the prices of two categories of product as different as traditional cables and busbars, it is necessary to make some preliminary
2014 NEC Guide Lines for Home Owner Doing Electrical Work on their Property
2014 NEC Guide Lines for Home Owner Doing Electrical Work on their Property A brief summary of the most used code references for residential wiring State of Idaho Division of Building Safety Electrical
Building Cables and Wires
Building Cables and Wires 4 Introduction alfanar is equipped with state-of-the-art manufacturing facilities such as latest machineries, instrumentation, quality control and testing laboratory, etc., for
HOUSTON COMMUNITY COLLEGE HCC ALIEF CAMPUS MAIN BUILDING, FIRST, SECOND & FOURTH FLOORS RENOVATION ISSUE DATE: 10.17.12
SECTION 27 05 26 - GROUNDING AND BONDING FOR COMMUNICATIONS SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes grounding and bonding products, design requirements and installation for communications
Ontario Electrical Safety Code - Info Sheet
Ontario Electrical Safety Code - Info Sheet The following are the Code requirements and explanatory material for buried electrical wiring that are applicable to most residential applications. 12-012 Underground
BASIC NEC CODE RULES AND DESIGN PRACTICE
BASIC NEC CODE RULES AND DESIGN PRACTICE Wire Ampacity and Size Circuit Breaker Size 1. Maximum loading for any branch circuit is 80% of rating of circuit for ampacity of wire for any load. NEC 220-2,
The original heating cable just got better
The making of the DEVIflex heating cable IEC 60800:2009 approved PVC outer sheath Install down to -5 C Round construction 360 full screening The original heating cable just got better DEVIflex Strong.
Terminal Cleaning and Protection
Terminal Cleaning and Protection East Penn offers the most complete line of terminal cleaning and protection products. Boots Heat Shrink Tubing Cleaner and Protection Sprays Terminal Protectors 33 PAGES
Electrical Safety Products
Electrical Safety Products Trelleborg Electrical Safety Products A safe working environment is important in all industries, but in the electrical generation and supply industry, it is paramount. Trelleborg
CHAPTER 4 UTILITY SYSTEMS ELECTRICAL. Utility Systems Electrical. Main Panel
CHAPTER 4 UTILITY SYSTEMS ELECTRICAL Utility Systems Electrical The electrical supply to your home begins outside, where you will see either an overhead feed and piping down the side of your home or (if