RE-ENTERABLE SPLICE CLOSURE KITS. (For Air Core None Pressurized Cable)

Size: px
Start display at page:

Download "RE-ENTERABLE SPLICE CLOSURE KITS. (For Air Core None Pressurized Cable)"

Transcription

1 Triple T Broadband Public Co., Ltd. Outside Plant Standard Sector Specification No. OES Issued: RE-ENTERABLE SPLICE CLOSURE KITS (For Air Core None Pressurized Cable) 1. SCOPE 1.1. This specification covers the requirements of re-enterable splice closure kits used for covering the splice conductors of aerial air core non-pressurized cable (Copper Cable) by Triple T Broadband Public Co., Ltd The re-enterable splice closure kits after referred to as the Aerial Closure shall comply with the requirements of this specification Documentations Bidder shall include in his aid sufficient information to permit a correct evaluation at the bid in relation to the specification including at least. Failure in this section the proposal shall be disqualified. Outline drawing showing principal dimensions and all materials used for each component and complete specification. Test report issued by the manufacturer to certify the product offered meeting the requirements as specified herein. Instruction describing the product of installation and re-opening. 2. GENERAL REQUIRMENTS 2.1. Closure Configurations The Aerial Closure shall be designed to handle all cable configurations according to the following definitions Straight an opening is provided for only one cable to enter each end of the closure. Branch Opening are provided for two or more cables enter one end of the closure Closure Housing The closure housing shall be compatible with all materials used in the construction of cable, bonding and grounding devices, chemicals, and splicing materials presently approved for use and which the closure would contact under normal use.

2 The closure housing shall be designed to be used as a free breathing and floating bond The closure housing shall be vented to prevent core water build up. The vents shall be provided to prevent insect entry in to the closure The closure housing shall be provided an external grounding stud which fixed firmly and strong enough at right bottom of back cover as shown in figure 2, and connect to cable shield with ground wire. When tighten the external grounding stud shall not be loosen or free The top of closure housing shall be secured with the over-center latch fasteners, which can be opened and closed without the use of tools. The cover shall swing down on its hinge to open the Aerial Closure. The number of the over-center latch fasteners shall depend on type and manufacturer s design The cable shield bonding shall be separated from the support bar and strand hangers. There shall be no electrical connect ability between the cable shield bonding and the support bar including strand hangers The Aerial Closure shall be equipped with two strand hangers for easier installation. All fastener hardware used for strand hanger such as nuts, bolts and other mounting hardware etc., shall be captivated to prevent accidental loss during installation and maintenance Both ends of closure shall be seal with spiral end caps. The spiral end caps can be sized, or selfadjusted to size, to seal the range of cables consistent with the splice diameters that will fit into the closures Installation of the closure shall not require special tools or instruments other than those normally carried by splicer of craftsman. 27. The closure kit shall consist of the following components: a) Closure Housing 1 set b) Support bar and PVC (or 1 set PE) insulated sleeve c) Strand Hangers 2 set d) Spiral end caps 2 pcs e) Shield continuity kitsas specified in Figure 1, Table I f) Ground wire 1 pc g) Installation in Thai or English language, include the description how to install and number of shield continuity wire and shield connector to be used or cable gauge and pair sizes. Page 2 of 9

3 OES Shield Continuity Kits One set of shield continuity kit shall composed of one shield continuity wire, two shield connectors and two heat protection sheets as follows Shield continuity wire/ground wire The wire consist of two pieces of minimum 1 mm thick electro-tin plated tempered brass terminal lugs and crimped to 0.75 mm thick PVC or PE insulated (green color), flexible tinned copper wire with minimum 19 stranded wires and minimum cross section area mm 2 (10 AWG) at each end. The length of shield continuity wire and ground wire shall depend on type of Aerial Closure and manufacturers design, but shall be easy to splice and install. The terminal lugs shall accommodate to shield connectors and grounding stud. The shield continuity wire and ground wire having insulated braid type with eyelets and equivalent property are allowable Shield connector The shield connector shall consist of four parts: lower member (base) with stud, upper member (top), two securing nuts (lock nut). The lower member shall be made of electro-tin plated tempered brass, and shall be burred perforated to make a good contact with cable shield. The stud shall be made of stainless steel (grade 300 series stainless steel) or electro-tin plated tempered brass and secured to lower plate, not loose or free during fastening. The upper member with teeth shall make of electro-tin plated tempered or brass to firmly grip the cable sheath. The two hexagonal lock nuts shall be made of stainless steel (grade 300 series stainless steel) or electro-tin plated tempered brass. The lower and upper member plated shall be slightly curved to exert a continuous spring force on sheath and shield after clamping. The shield connector shape used may be different from the shield connector shown in figure 1 but its major assembly parts and material used shall conform this section Heat protection sheet The heat protection sheet shall be made of minimum 0.45 mm thick, fire-retardant (UL94- V0) plastic material. Its dimension shall be suitable with shield connector. The heat protection sheet shall be used for inserting between shield connector and cable core to protect cable core from heat during electrical surge. The shield continuity kit shall be as shown in figure 2. Page 3 of 9

4 OES External grounding The external grounding stud shall made of electro-tin plated tempered brass or stainless steel (grade 300 series) and formed into good design no obstruction for installation and closure performance The external grounding shall at least accommodate to a # 6 AWG copper wire and provided the two hexagonal lock nuts and made of stainless steel (grade 300 series) or electrotin plated tempered brass The external grounding stud shall be completely provided and already fixed with the back cover (see Figure 2). Heat Protection sheet Shield continuity wire/ground wire Figure 1 Typical shield continuity kit I set External grounding F figure 2 External grounding stud positions

5 3. MATERIAL REQUIREMENTS The materials used in all components of the Aerial Closure must function in the application environment. Corrosion Metals shall be resistant and/or protected against general corrosion. Chemical Plastics shall be resistant to deterioration when exposed to ultra-violet rays of the sun for prolonged periods. 31. The closure housing shall be made from black durable high density thermoplastic, which resists to solvent and stress cracking and be compatible with all materials used in the construction of cable, bonding and grounding devices, chemicals, and splicing materials presently approved for use and which the closure would contact under normal use. 32. The support bar shall be made of minimum 1.5 mm thick aluminum sheet (or grade 300 series stainless steel) in U-shape. The PVC (or PE) sleeve shall be black color and at least 0.8 mm thick. The support bar shall be fully insulated and covered by such sleeves The spiral end caps shall be made of black high density closed cell foam rubber. The closed cell foam rubber shall be made of EPDM (Ethylene propylene diene monomer) or better quality material. The closed cell foam rubber shall fit snugly around each cable, prevent the entrance of water into the splice, keep insects from entering closure, The closed cell foam rubber, which are installed in the closure ends, shall be pre-cut and have perforated punchouts to accommodate a large of cable diameters The over-center latch fasteners shall be made of minimum 2.4mm diameter stainless steel, grade 304 meeting all the requirement of the ASTM A358 Standard Specification for Electric- Fusion-Welded Austenitic Chromium-Nickel Stainless Steel Pipe for High-Temperature Service and General Applications (or grade 300 series stainless steel). The number of overcenter latch fasteners shall depend on type of closures and manufacturers design. 35. The strand hangers shall be made of stainless steel (grade 300 series stainless steel) or aluminum. The hexagonal head of lock bolts shall be made of stainless steel (grade 300 series stainless steel) or electro-tin plated brass. 36. The other metallic components excluding specified as per sections 3.1 to 3.5 shall be made of stainless steel (grade 300 series stainless steel) or aluminum All parts of external grounding terminal shall be made of stainless steel (grade 300 series stainless steel) or electro-tin plated tempered brass. Page 5 of 9

6 4. PERFORMANCE REQUIREMENTS 4.1. Electrical Requirements Shield Connector Resistance The contact resistance between shield connector and cable shield shall be less than 2 mfl. The measurement technique must conform to ASTM B Method C Surge Test The bonding between the shield connector and cable shield shall be capable of withstanding a current of 500 Amps for 3 seconds (except RAI type applied 300 Amps for 3 seconds). After testing, the shield connector shall be display no evidence of crack, breaking or melting, no damage shall occur to the cable core or the outer sheath adjacent to the bond Tensile pull-out The shield connector shall be attached to the cable shield and tested at temperature 27+5C, the speed of jaw separation shall be 50 mm/mm. The tensile pull-out shall not be less than 300 N Mechanical Requirements The term ~complete closure assembly refers to a test sample in which a closure has been completely assembled (including bonding, etc.) according to the manufacturer s instructions over an actual cable splice made with unfilled single wire connectors or modular connectors, using a fold-back splice Impact A completed closure assembly shall be subjected to an impact of 1.4 kg-m, at ambient room temperature. The apparatus shall consist of a cylindrical steel impacting head weighing 2 kg. The test procedure shall be as follows The closure assembly with cable stubs shall be attached to steel wire strand simulating an aerial installation. The assembly shall be constrained to prevent the closure from rotating beyond 90ฐ of it normal position. The impacting head weighing 2 kg shall be at least 25 mm in diameter and shall have spherical radius on the end which impacts the closure. The test assembly shall be positioned to ensure the impacting head strike the assembly at the approximate mid-point of its dimensions. The impact head shall be released from a test stand with a pendulum motion though a height of 0.6 m to achieve the required impact force. Any damage or cracking to the closure housing constitutes failure of this test. Page 6 of 9

7 Axial Pull Test A completed closure assembly shall be subjected to axial cable sheath movement of 100mm from the normally assembled position. The cable stubs shall be of sufficient length to provide for grasping the cable 0.5 m from its entrance into the closure. After subjecting each cable entering the closure to this movement the sheath opening shall not extend outside the closure Re-entry Test The closure housing shall withstand the re-entry of cover at least 500 cycles. A re-entry cycle shall consist of : swing the font cover up and down with swinging angle of 135 ± 5, 20 cycles per minute. After complete the test, the hinge of the closure shall show no evidence of cracking Environmental Requirements Temperature Cycling The assembled closure shall be exposed to a temperature cycle from 40 F (4.4 C) to 140 F (60 C) at 95% relative humidity as per Figure 3 for 30 days. Allow the Aerial Closure to stabilize at room temperature for a minimum of 2 hours after complete temperature cycles. There shall be no visible deterioration, deformation, melting or cracking of aged samples Fungus Resistance The method shall follow in principle of ASTM G-21 latest issue. A rating of 0 is required Ultraviolet Resistance The samples cut from non-materials of closure shall be subjected to 700 hours exposure per ASTM G-26 and ASTM D-2565, procedure A, using type RH apparatus. The exposed samples shall be tested for tensile strength and elongation per ASTM D-638 at 50 mmlminute. A comparison of values after the test shall be made. A drop of 20% or more in properties constitutes failure Carbon Black Content The samples cut from plastic ofclosure shall be tested the content of carbon black in accordance with ASTM D-1603 latest issue. The content of carbon black shall not be less than 2% by weight. Page 7 of 9

8 Salt Fog The assembled closure shall be exposed to a salt fox spray in accordance with ASTM B-I 17 for 30 days. After testing, remove out the closure from the chamber and wash with warm, clean water. All metallic components of the closure shall be examined with naked eyes. There shall be no evidence of corrosion of metallic components. 5. MARKING 51. The closure shall be identifiable and permanently marked by the manufacturer s name. The month and year of manufacture shall be clearly located on the closure to provide traceability The closure shall show a permanent TTT trade-mark or logo, if specified in commercial condition. 6. ORDERING INFORMATION Ordering information shall be specified in Table I. Code Closure Type Cable Spliced (Pair) Shield, Continuity kit (Set) Standard. Packing 0.4 0_S RAI I ST/BX RA2 200 ISO ST/BX RA ST/BX RA ST/BX RAS ST/BX RA ST/BX RA ST/BX Table 1

9 6.1. The type of inlets and outlets (SE, DE, and TE) shall be specified in the bid form. SE: Single Entry End Cap DE: Double Entry End Cap TE: Triple Entry End Cap 6.2. The connectors types used for this closure are as follows The single connectors in accordance with TTT s specification Standard latest issue shall be used for cable less than 300 pairs The wire connectors module with gel encapsulated in accordance with TTT s specification standard latest issue shall be used for cable not less than 300 pairs The dimensions of the closure shall be suitable with the pair of cable spliced which specified in Table PACKING Each aerial splice closure kit shall be packed in specially designed reinforced cardboard box and labeled to show contract number, the description, type, size and the name of the supplier. Temperature ( C) Time (Hours) Relative Humidity = 95% Figure 3 End of Specification Page 8 of 9

Section 21. Telecommunication Hardware. www.geindustrial.com BuyLog Catalog 21-1

Section 21. Telecommunication Hardware. www.geindustrial.com BuyLog Catalog 21-1 Introduction...21-1 Fiber Closure Hardware...21-2 Cable Location Surge Protectors...21-4 Introduction GE has been manufacturing Telecommunication Hardware products for over 20 years and has become a leader

More information

C O N V E Y O R C O M P O N E N T S C H A I N S B E L T S B E A R I N G S

C O N V E Y O R C O M P O N E N T S C H A I N S B E L T S B E A R I N G S C O N V E Y O R C O M P O N E N T S C H A I N S B E L T S B E A R I N G S January 2009 Issue 6 Valu Guide Brackets The Ultimate in Adjustability and Cost Savings Valu Guide brackets are part of a family

More information

T A B L E T 1 T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A

T A B L E T 1 T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A T A B L E T 1 1 of 7 Tests & Inspection Cable PCUT & PCUT-A (Table T1) T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A No. Test Scale MOC Requirements G 20:10:001:01 Defined Test

More information

Waterproof Connectors for Outdoor Use

Waterproof Connectors for Outdoor Use Waterproof Connectors for Outdoor Use HR41A Series Mated condition diagram Nut-tightening rear mount type (panel thickness=mm) 70.5 Features 1. Waterproof connector designed for outdoor use Light-weight

More information

SlimSeal SSL Connector. Now Available in 1 Position. Free Hanging Version

SlimSeal SSL Connector. Now Available in 1 Position. Free Hanging Version Now Available in 1 Position Free Hanging Version SlimSeal SSL Connector The SlimSeal SSL connectors are low profile, single row connectors developed for indoor and outdoor LED lighting applications. These

More information

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE 4 3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE A. Changing the Control Board B. Replacing a Heating Element C. Thermistor Replacement D. High Limit Switch Replacement E. Level Detector Replacement

More information

AMP Standard Terminals and Splices. RoHS. Ready

AMP Standard Terminals and Splices. RoHS. Ready AMP Standard Terminals and Splices RoHS Ready Table of Contents Product Facts Solderless terminals and splices performs up to today s standards for reliable termination in applications ranging from control

More information

Figure 1 (end) Updated document to corporate requirements Added text to Paragraph 2.4

Figure 1 (end) Updated document to corporate requirements Added text to Paragraph 2.4 This specification covers the requirements for application of ELCON Drawer Series Connectors: True Hot Plug, Blind Mating Mixed Signal and Power Connectors. These connectors are designed for use in pluggable

More information

2178-S Fiber Optic Splice Case and Accessories

2178-S Fiber Optic Splice Case and Accessories 2178-S Fiber Optic Splice Case and Accessories Tech Report October 1996 80-6109-3154-7 1 Contents: 1.0 Product Description... 3 2.0 Test Program Overview... 4 3.0 Environmental Tests... 5 4.0 Mechanical

More information

NORTH ORANGE COUNTY COMMUNITY COLLEGE DISTRICT SECTION 27 05 26 GROUNDING AND BONDING FOR COMMUNICATION SYSTEMS

NORTH ORANGE COUNTY COMMUNITY COLLEGE DISTRICT SECTION 27 05 26 GROUNDING AND BONDING FOR COMMUNICATION SYSTEMS SECTION GROUNDING AND BONDING FOR COMMUNICATION SYSTEMS RELATED SECTIONS: Section 27 00 00 General Requirements Section 27 02 00 Communication General Requirements Section 27 05 28 Pathways for Communications

More information

AMPSEAL* Automotive Plug Connector and Header Assembly

AMPSEAL* Automotive Plug Connector and Header Assembly AMPSEAL* Automotive Plug Connector and Header Assembly Application Specification 24 SEP 97 Rev E All dimensions are given in millimeters unless otherwise specified. All dimensional tolerances are +0.2

More information

Installation guide for the SafeLine type anchorage device. Tested in compliance with EN 795: 1996. No.: SE-...

Installation guide for the SafeLine type anchorage device. Tested in compliance with EN 795: 1996. No.: SE-... Installation guide for the SafeLine type anchorage device Tested in compliance with EN 795: 1996 No.: SE-... Version: 09.10.2008 SE 67 Subject to technical alterations! Contents 1. General information

More information

Directory chapter 02 - DIN Power (to 6 A) Types D, E, F, FM, 2F, F9, interface connectors I/U 02. 01. Technical characteristics types D and E... 02.

Directory chapter 02 - DIN Power (to 6 A) Types D, E, F, FM, 2F, F9, interface connectors I/U 02. 01. Technical characteristics types D and E... 02. Directory chapter 02 - () Types D, E, F, FM, 2F, F9, interface connectors I/U Page Technical characteristics types D and E.............................. 02.10 Type D connectors.................... 02.11

More information

HARTING Ethernet Cabling 8-poles Overview

HARTING Ethernet Cabling 8-poles Overview Ethernet Cabling 8-poles Overview RJ45 Connectors [on page 8] System cables [on page 12] Distribution modules and Outlets [on page 17] Connectors [on page 20] System cables [on page 26] Panel feed-throughs

More information

Outdoor Use Waterproof I/O Connectors (Optical / Modular / Electrical) FO-BH, FO-BC, NT5, JN2 / W Series

Outdoor Use Waterproof I/O Connectors (Optical / Modular / Electrical) FO-BH, FO-BC, NT5, JN2 / W Series COMPONENTS PRODUCT INFORMATION RoHS Compliant NEW Outdoor Use Waterproof I/O Connectors (Optical / Modular / Electrical) FO-BH, FO-BC, NT5, JN2 / W Series Optical FO-BH Series (Compact Type) CONNECTOR

More information

5.2. Overview. The better method to install solderless compression connectors on power cable

5.2. Overview. The better method to install solderless compression connectors on power cable 5.2 Overview The better method to install solderless compression connectors on power cable The Thomas & Betts method of installing compression connectors on power cables is designed to provide a high degree

More information

SECTION 02720 SANITARY SEWER AND STORM DRAIN SYSTEMS

SECTION 02720 SANITARY SEWER AND STORM DRAIN SYSTEMS SECTION 02720 SANITARY SEWER AND STORM DRAIN SYSTEMS PART 1 GENERAL 1.01 SECTION INCLUDES A. The requirements for pipe material and installation in sewer and drainage collection systems. All materials

More information

Directory chapter 04

Directory chapter 04 M Directory chapter 04 D-Sub Mixed subminiature D connectors New Page D-Sub mixed connector system general information................... 04.02 Contact arrangements............................................

More information

CABLE SPECIFICATION CAN CAB RJ45-SUBD9

CABLE SPECIFICATION CAN CAB RJ45-SUBD9 CABLE SPECIFICATION All technical information contained in this document is the exclusive property of STI and may neither be used nor disclosed without its prior written consent. AAV 33801 1/8 Connector

More information

Nordson Automatic Spray Gun Support Kits

Nordson Automatic Spray Gun Support Kits Nordson Automatic Spray Gun Support Kits Customer Product Manual Issued / For parts and technical support, call the Finishing Customer Support Center at (800) -99. This document is subject to change without

More information

White paper. SACE Tmax XT Circuit-Breaker Terminals and Connection

White paper. SACE Tmax XT Circuit-Breaker Terminals and Connection White paper SACE Tmax XT Circuit-Breaker Terminals and Connection Circuit-Breaker Terminals and Connections Index Introduction... 2 1. Components used for wiring... 3 1.1. Electrical...3 1.2. Flexibility

More information

TRITON CONTAINER INTERNATIONAL. Reefer Technical Bulletins. Version 4.0

TRITON CONTAINER INTERNATIONAL. Reefer Technical Bulletins. Version 4.0 TRITON CONTAINER INTERNATIONAL Version 4.0 February 2013 Table Of Contents (Hold Ctrl button and click on any item below to go directly to that section of the manual.) 1 INTRODUCTION... 3 2 REFRIGERATED

More information

COAXICON Contacts. RF Coax Connectors. Product Facts

COAXICON Contacts. RF Coax Connectors. Product Facts COXICON Contacts Product Facts Tyco Electronics provides a variety of contacts for coaxial connectors Contacts are available in a range of sizes that may be used with the various types of coaxial cable

More information

SECTION 15076 CEMENT-MORTAR LINED AND COATED STEEL PIPE

SECTION 15076 CEMENT-MORTAR LINED AND COATED STEEL PIPE SECTION 15076 CEMENT-MORTAR LINED AND COATED (CML&C) STEEL PIPE PART 1 GENERAL 1.01 DESCRIPTION This section designates the requirements for steel pipe fabrication, test in shop, installation of steel

More information

01. HARTING RJ INDUSTRIAL RJ45 ETHERNET CONNECTORS

01. HARTING RJ INDUSTRIAL RJ45 ETHERNET CONNECTORS . HARTING RJ INDUSTRIAL ETHERNET CONNECTORS Ethernet is is coming up to standard industrial interface. Therefore, automation devices such as controllers, sensors and actuators feature possess on one or

More information

Application Specification SIAMEZE * Standard and 114-13166 Fine Range Terminals 18 Mar 11 Rev C

Application Specification SIAMEZE * Standard and 114-13166 Fine Range Terminals 18 Mar 11 Rev C Application Specification SIAMEZE * Standard and 4-66 Fine Range Terminals 8 Mar Rev C NOTE i All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters

More information

2178-S Fiber Optic Splice Case

2178-S Fiber Optic Splice Case 2178-S Fiber Optic Splice Case Instructions March 1998 34-7041-6288-1-B 1 2 Table of Contents 3M 2178-S Splice Case Description... 4 1.0 General...4 2.0 Specifications...4 3.0 Kit Contents...5 3M 2178-S

More information

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant). Fittings for CO 2 Pipe Threads Pipe thread references quoted in this catalogue conform with the requirements specified in the latest issue and amendments of the following ISO Standards: ISO 7-1 (BS21)

More information

Industrial circular connectors

Industrial circular connectors Industrial circular connectors M 16 M 58 010 CONINVERS - M16 to M58 circular connectors for industrial applications CONINVERS GmbH, an independent company, is the specialist for M16 to M58 circular connectors

More information

HOUSTON COMMUNITY COLLEGE HCC ALIEF CAMPUS MAIN BUILDING, FIRST, SECOND & FOURTH FLOORS RENOVATION ISSUE DATE: 10.17.12

HOUSTON COMMUNITY COLLEGE HCC ALIEF CAMPUS MAIN BUILDING, FIRST, SECOND & FOURTH FLOORS RENOVATION ISSUE DATE: 10.17.12 SECTION 27 05 26 - GROUNDING AND BONDING FOR COMMUNICATIONS SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes grounding and bonding products, design requirements and installation for communications

More information

CDGRD-10. Grounding. Solutions For Comm/Data Applications

CDGRD-10. Grounding. Solutions For Comm/Data Applications CDGRD-10 Grounding Solutions For Comm/Data Applications Overview & Table of Contents Cooper B-Line s Grounding products for rack & runway provide a complete solution for grounding metal supports. The offering

More information

Universal MATE-N-LOK Connectors

Universal MATE-N-LOK Connectors Product Facts Pins and sockets can be intermixed in the same housing Positive polarization Rear cavity identification completely enclosed in housings Positive locking housings Insulation capability to.00

More information

CP2 Buried Cable Pedestal Initial & Rehab Installation Instructions

CP2 Buried Cable Pedestal Initial & Rehab Installation Instructions Printing 3 March 2008 CP2 Buried Cable Pedestal Initial & Rehab Installation Instructions This instruction is intended for CP2 cable pedestal installations and replacements. The following tools will be

More information

Digital inductive conductivity transmitter

Digital inductive conductivity transmitter Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections

More information

This presentation to be used in conjunction with:

This presentation to be used in conjunction with: 1 This presentation to be used in conjunction with: Spec Sheets: SA-GRSP10, SA-GRSP09, SA-GRSP11 Samples in DC-GROUND-KIT 8/16/2012 2 Network Bonding and Grounding: TIA-607-B Generic Telecommunications

More information

PLATE HEAT EXCHANGER. Installation Manual. Customer Name: Serial number: Purchase order number: Project:

PLATE HEAT EXCHANGER. Installation Manual. Customer Name: Serial number: Purchase order number: Project: PLATE HEAT EXCHANGER Installation Manual Customer Name: Serial number: Purchase order number: Project: Table of Contents ----------------------------------------------------------------- Page: 2 3 Name

More information

HARTING Ethernet Cabling 4-poles Overview

HARTING Ethernet Cabling 4-poles Overview Ethernet Cabling 4-poles Overview RJ45 Connectors [on page 8] System cables [on page 10] Distribution modules and Outlets [on page 20] Connectors [on page 22] System cables [on page 24] Panel feed-throughs

More information

ULTIMATE SNAP-N-SEAL

ULTIMATE SNAP-N-SEAL ULTIMATE SNAP-N-SEAL F Series Compression Connectors Thomas & Betts introduces the Ultimate Snap-N-Seal Compression Connector, the newest addition to the Snap-N-Seal system. Look for the classic design

More information

CORNING CABLE SYSTEMS GENERIC SPECIFICATION FOR TIGHT BUFFER OPTICAL FIBER CABLES FOR INTER- AND INTRABUILDING APPLICATIONS.

CORNING CABLE SYSTEMS GENERIC SPECIFICATION FOR TIGHT BUFFER OPTICAL FIBER CABLES FOR INTER- AND INTRABUILDING APPLICATIONS. CORNING CABLE SYSTEMS GENERIC SPECIFICATION FOR TIGHT BUFFER OPTICAL FIBER CABLES FOR INTER- AND INTRABUILDING APPLICATIONS September 2006 Revision 7 Corning Cable Systems reserves the right to update

More information

Cable Guide. Cables, Connectors & Tools for installation of quality networks. TRIAX - your ultimate connection

Cable Guide. Cables, Connectors & Tools for installation of quality networks. TRIAX - your ultimate connection Cable Guide Cables, Connectors & Tools for installation of quality networks TRIAX - your ultimate connection A Selection of the best Triax TX Cable range optimised for digital reception Simplification

More information

SECTION 26 05 49 VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

SECTION 26 05 49 VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS SECTION 26 05 49 VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes seismic restraints and other earthquake-damage-reduction measures for electrical

More information

* Please visit the product pages on our website for the most up-to-date product information. Con-X Molded Cable Assembly Checklist...

* Please visit the product pages on our website for the most up-to-date product information. Con-X Molded Cable Assembly Checklist... TABLE OF CONTENTS Custom Molded Cable Assemblies and Connectors..........................2 Capabilities.....................................................................3 Standard Connector Products.......................................................4

More information

Installation instruction CASAFLEX - Connecting piece DN 100

Installation instruction CASAFLEX - Connecting piece DN 100 1 CASAFLEX - 11 10 114,3 x 4,5 3 5 2 4 1 7 6 8 12 9 Do not begin work until you have read the installation instruction carefully. 1 internal backing sleeve 2 graphite packing 3 connecting piece 4 thrust

More information

LIEBERT VNSA Installation Sheet

LIEBERT VNSA Installation Sheet LIEBERT VNSA Installation Sheet Description The Liebert vnsa network switch is designed for connecting multiple Ethernet-ready devices and comes in various models. The unit may have: A Liebert icom display

More information

Mechanical arms, belts and sheets

Mechanical arms, belts and sheets Car parks Mechanical arms, belts and sheets DETAIL ARM CAR PARK (mm) 5000 Platen 100x5mm Iron sheets 4mm 5000 485 2100 Belts type C 120x50x2 mm 4915 5400 Hot dipped galvanized UNE-EN ISO 1461 or black

More information

Assembly Instruction CAI- Connector with universal Endbell

Assembly Instruction CAI- Connector with universal Endbell CANNON STANDARD Seite 1 von 17 CAI- Connector with universal Endbell Shell size 10 to 36 with APK contact / Trident T2P - contact Illustration and assembly exemplary of CAI Layout 20-0306 with APK / Trident

More information

SYSTEM 1850-SE SERVICE ENTRANCE CABLE SYSTEM

SYSTEM 1850-SE SERVICE ENTRANCE CABLE SYSTEM Pyrotenax SYSTEM 1850-SE SERVICE ENTRANCE CABLE SYSTEM Contents Introduction This section provides an overview of general circuit design considerations and installation guidelines for a Pyrotenax System

More information

UGVCL/SP/591/11KV HT AB CABLE

UGVCL/SP/591/11KV HT AB CABLE TECHNICAL SPECIFICATION FOR 11KV AERIAL BUNCHED CABLES FOR OVERHEAD LINES (CROSSED LINKED POLYTHENE DRY GAS CURED) 1. SCOPE This specification covers requirements of XLPE insulated, 11 KV Aerial Bunched

More information

white paper Ferrules: Your Best Insurance Against Costly Connection Failure Executive Summary

white paper Ferrules: Your Best Insurance Against Costly Connection Failure Executive Summary Ferrules: Your Best Insurance Against Costly Connection Failure white paper Executive Summary Thanks to its superior flexibility, longer flex life*, and resistance to vibration, insulated stranded wire

More information

114-22008. 8-Position Cat5e (EMT) Modular Plug Connectors. Application Specification

114-22008. 8-Position Cat5e (EMT) Modular Plug Connectors. Application Specification Application Specification 114-22008 02/May/2008 Rev H 8-Position Cat5e (EMT) Modular Plug Connectors NOTE All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are

More information

Anodes and Misc Equipment

Anodes and Misc Equipment Anodes and Misc Equipment Application: Platinised Titanium Anodes Platinised titanium anodes are recommended for use in the following electrolytic processes:- Precious metal electroplating - e.g. Au, Pt,

More information

INNOVATION SUPPORTED BY A TRULY SOLID INDUSTRIAL ORGANIZATION.

INNOVATION SUPPORTED BY A TRULY SOLID INDUSTRIAL ORGANIZATION. CONNECTORS 2014 INNOVATION SUPPORTED BY A TRULY SOLID INDUSTRIAL ORGANIZATION. Stelvio Kontek S.p.A. is one of the leading groups in the connectors market. With a solid background in the sector and having

More information

James M. Pleasants Company

James M. Pleasants Company James M. Pleasants Company SUBMITTAL DATA GAINESVILLE MECHANICAL DECEMBER 20, 2013 PROJECT: GSU: J-183 HUMANITIES LAW BLDG. QUOTE NO:12116 ENGINEER: STEVENS & WILKINSON GASKETED PLATE HEAT EXCHANGER Tag:

More information

400 Series - Mini USB Buccaneer

400 Series - Mini USB Buccaneer IP68 Sealed IP68 rated USB V2.0 performance Plug and play capability Shielded system Overmoulded cables Screw coupling PCB versions Dust and waterproof to EN60529 Data rates up to 480Mbs Hot pluggable,

More information

Elo Touch Solutions Wall-mounting Kit for the 5501L IDS Touchmonitors

Elo Touch Solutions Wall-mounting Kit for the 5501L IDS Touchmonitors Installation Manual Elo Touch Solutions Wall-mounting Kit for the 5501L IDS Touchmonitors SW602206 Rev B Table of Contents Chapter 1: Safety Warning... 3 Chapter 2: Kit Contents... 4 Included in Kit...

More information

TERMINATION ENCLOSURE OPTIONS

TERMINATION ENCLOSURE OPTIONS TERMINATION ENCLOSURE OPTIONS Add suffix: R - Reverse Stagger the Bus Bars (to run cable in from the top) CU - Copper NEMA Mount Bus Bars C - Plastisol Covers for Bus Bars DF - Dead Fronts T - Tin Plated

More information

Wire, Cable, and Battery Accessories Product Catalog

Wire, Cable, and Battery Accessories Product Catalog Wire, Cable, and Battery Accessories Product Catalog East Penn s Wire and Cable division is housed in a 250,000 square-foot facility equipped with state-of-the-art technology utilizing sound yet advanced

More information

IEEE POWER ENGINEERING SOCIETY CHICAGO CHAPTER THE OKONITE COMPANY WEDNESDAY JANUARY 11, 2006 JIM FITZGERALD ENGINEERING LINGO

IEEE POWER ENGINEERING SOCIETY CHICAGO CHAPTER THE OKONITE COMPANY WEDNESDAY JANUARY 11, 2006 JIM FITZGERALD ENGINEERING LINGO IEEE POWER ENGINEERING SOCIETY CHICAGO CHAPTER THE OKONITE COMPANY WEDNESDAY JANUARY 11, 2006 JIM FITZGERALD ENGINEERING LINGO WHEN YOU HEAR AN ENGINEER SAY A NUMBER OF DIFFERENT APPROACHES ARE BEING IMPLEMENTED

More information

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance SPECIFICATION FOR LOW VOLTAGE SWITCHBOARD SEN I N D E X Description 10 STANDARD TECHNICAL REQUIREMENTS 11 Standards 12 General Operating Conditions 13 General Description Of Switchboard 131 Structure 132

More information

KIRÁLY TRADING KFT H-1151 Budapest Mogyoród útja 12-14 tel: 061307-3801 Email_pzoli@kiralytrading.hu. Clamps Clamping devices

KIRÁLY TRADING KFT H-1151 Budapest Mogyoród útja 12-14 tel: 061307-3801 Email_pzoli@kiralytrading.hu. Clamps Clamping devices 04000 Clamps Clamping devices 23000 22000 21000 20000 09000 08000 07000 06000 05000 04000 03000 02000 01000 297 04010 Adjustable straps Tempered steel 1.1191 Black oxide finish nlm 04010-101 Suitable thrust

More information

25-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp and 1250 Amp

25-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp and 1250 Amp Page 1 2015 Grounded Metal Equipment Plate Equipment Connection Bus Bar or Other Component 15 kv or 25 kv Separable Insulated Connector (elbow) Equipment Connection Power Cable Power Cable Grounded Metal

More information

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered Electrical Temperature Measurement DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered WIKA Data Sheet TE 60.75 Applications Machinery, plant and tank construction

More information

Terminal Boxes Series 8146

Terminal Boxes Series 8146 Series > Enclosures in shock-resistant glass fibre reinforced polyester resin > basic enclosure sizes various heights > Fitted according to the customer's requirements > For terminals up to max. 00 mm

More information

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000 RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000 SECTION R905 REQUIREMENTS FOR ROOF COVERINGS R905.1 Roof covering application. Roof coverings

More information

TECHNICAL SPECIFICATION FOR HIGH TENSION LINE HARDWARE AND ACCESSORIES FOR ACSR PANTHER & WOLF CONDUCTOR

TECHNICAL SPECIFICATION FOR HIGH TENSION LINE HARDWARE AND ACCESSORIES FOR ACSR PANTHER & WOLF CONDUCTOR TECHNICAL SPECIFICATION FOR HIGH TENSION LINE HARDWARE AND ACCESSORIES FOR ACSR PANTHER & WOLF CONDUCTOR 1.1.0 SCOPE : This specification covers design, manufacture, testing at manufacture s works before

More information

Machine devices, jig devices

Machine devices, jig devices Machine devices, jig devices 853 K0697 Rolled thread studs DIN 6379 Material: Tempered steel. KIPP Rolled thread studs DIN 6379 Order No. D L B1 B2 Approx. weight g Surface finish: Thread rolled. Class

More information

Les Produits MURPHCO Ltée

Les Produits MURPHCO Ltée DESCRIPTION The Murphco support clamp is an assembly made entirely of stainless steel and conceived for all sleeved roof drains. The Murphco Support Clamp is compatible with all types of Murphco* copper

More information

HARTING Ethernet Cabling 4-poles Overview

HARTING Ethernet Cabling 4-poles Overview Overview RJ45 Connectors [on page 8] System cables [on page 10] Distribution modules and Outlets [on page 20] HARTING PushPull Connectors [on page 22] System cables [on page 24] Panel feed-throughs [on

More information

3M Fiber Optic Splice Closure 2178-LS Series with Gasket

3M Fiber Optic Splice Closure 2178-LS Series with Gasket 3M Fiber Optic Splice Closure 2178-LS Series with Gasket Instructions for: 3M Fiber Optic Splice Closures 2178-LS Series 3M Flame Retardant Fiber Optic Splice Closures 2178-LS/FR 3M Cable Addition Kit

More information

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M1115-2 (Angle) Schematic. Standard Components

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M1115-2 (Angle) Schematic. Standard Components Schematic Throttles to reduce high upstream pressure to constant lower downstream pressure Throttles to maintain minimum upstream pressure PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE

More information

08. SEK IDC CONNECTORS

08. SEK IDC CONNECTORS . IDC CONNECTORS connectors for flat cables enable simple and, cost-optimized device configuration. connectors are preferably used for connection within the device. HARTING offers a broad range of these

More information

Drive shaft, servicing

Drive shaft, servicing Volkswagen Passat B6 - Drive shaft, servicing Стр. 1 из 41 40-7 Drive shaft, servicing Drive shafts, overview I - Assembly overview: Drive axle with CV joint VL100 40-7, Drive axle with CV joint VL100,

More information

Wind Direction Smart Sensor (S-WDA-M003)

Wind Direction Smart Sensor (S-WDA-M003) (S-WDA-M003) The Wind Direction smart sensor is designed to work with HOBO Stations. The smart sensor has a plug-in modular connector that allows it to be added easily to a HOBO Station. All sensor parameters

More information

Two Position Cable-to-Board Power Connector System (Right Angle/Straight) with Coding Contacts

Two Position Cable-to-Board Power Connector System (Right Angle/Straight) with Coding Contacts Product Specification 108-19346 17 APR 2013 Rev F Two Position Cable-to-Board Power Connector System (Right Angle/Straight) with Coding Contacts 1. SCOPE 1.1. Content NOTE The product may not perform according

More information

Hook-Up and Lead Wire

Hook-Up and Lead Wire 3.1 Hook-Up and Lead Wire 3 Table of Contents Hook-Up & Lead Wire Page Introduction: UL Style & CSA Type Listings 3.2 PVC 3.3 3.8 300V, 80 C 3.3 300V, 105 C 3.4 600V, 105 C 3.5 (Type MW) MIL-W-76C-PVC:

More information

Quick Reference Guide Euro Style Terminal Blocks

Quick Reference Guide Euro Style Terminal Blocks Quick Reference Guide Euro Style terminal block connectors feature various wire termination methods including rising cage clamp, wire protector, spring, IDC and crimp snap. The design of terminal block

More information

PRESSURE REDUCING CONTROL VALVE

PRESSURE REDUCING CONTROL VALVE Schematics Throttles to reduce high upstream pressure to constant lower downstream pressure Low Flow By-Pass controls at low flows 4 PRESSURE REDUCING CONTROL VALVE with LOW FLOW BY-PASS FEATURE Main Line

More information

Navico-Northstar 2kW JRC Radar Package, Scanner Cable Removal and Replacement

Navico-Northstar 2kW JRC Radar Package, Scanner Cable Removal and Replacement Navico-Northstar 2kW JRC Radar Package, Scanner Cable Removal and Replacement This work instruction describes the methods and means for which to remove and reinstall optional scanner cable configurations

More information

CITY OF BEAUFORT SOLICITING SEALED PROPOSALS FOR MOBILE REFUSE CARTS

CITY OF BEAUFORT SOLICITING SEALED PROPOSALS FOR MOBILE REFUSE CARTS CITY OF BEAUFORT SOLICITING SEALED PROPOSALS FOR MOBILE REFUSE CARTS The City of Beaufort is requesting sealed, competitive, proposals for interested Vendors to provide the City of Beaufort fifty-five

More information

SECTION 15140 - PIPE HANGERS AND SUPPORTS

SECTION 15140 - PIPE HANGERS AND SUPPORTS Part I - GENERAL 1.01 SECTION INCLUDES A. The work covered under this section consists of the furnishing of all necessary labor, supervision, materials, equipment, and services to completely execute the

More information

AutoLink Three-Phase Sectionalizer Specifications. Scope. General. Applicable Standards. Operating principle

AutoLink Three-Phase Sectionalizer Specifications. Scope. General. Applicable Standards. Operating principle Scope This specification stipulates the minimum requirements for mechanically linked three-phase electronic sectionalizers, for use on outdoor medium voltage overhead lines of 15, 27, and 38 kv. Electronic

More information

The Contractor shall furnish and install all shielded power cable suitable for use on this project.

The Contractor shall furnish and install all shielded power cable suitable for use on this project. Section 16122 PRIMARY POWER CABLES PART 1 GENERAL: WORK INCLUDED The Contractor shall furnish and install all shielded power cable suitable for use on this project. RELATED WORK Section 16020: Tests SUBMITTALS

More information

Aluminium Standard. Technical Data. Included in delivery

Aluminium Standard. Technical Data. Included in delivery luminium Standard UL / cul Robust aluminium enclosure for mechanical engineering and automation technology Fixing options for s and mounting plates Usable in wide temperature area Technical ata aterial:

More information

MICRO SFP+ CONNECTOR & CABLE ASSEMBLY

MICRO SFP+ CONNECTOR & CABLE ASSEMBLY MICRO SFP+ CONNECTOR & CABLE ASSEMBLY micro SFP+ Connector and Cable Assembly TE Connectivity s (TE) micro SFP+ connector and cable assembly empower you to dream big when designing your communication system.

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS ODEON IN-WALL TANK K-6283K/ K-6284K/ K-6286K Read installation guide in illustration and word file carefully, and install the tank according to instructions in the guide to avoid

More information

EXPLORE 4-Leg Teaming Table with Screen Share Assembly Instructions

EXPLORE 4-Leg Teaming Table with Screen Share Assembly Instructions EXPLORE 4-Leg Teaming Table with Screen Share Monitor Display Requirements: your flat panel display must confirm to the following requirements. y With the stand removed, the monitor must not exceed 40

More information

Linkeo 19" freestanding cabinets

Linkeo 19 freestanding cabinets 87045 LIMOGES Cedex France Telephone: (+33) 05 55 06 87 87 - Fax: (+33) 05 55 06 88 88 Linkeo 19" freestanding cabinets Page 1. General characteristics....1 2. Range....2 3. Technical characteristics...3

More information

Economy Combo Heat Press Manual Model No.: ECH-800

Economy Combo Heat Press Manual Model No.: ECH-800 Economy Combo Heat Press Manual Model No.: ECH-800 CONTENTS I. Assembly Drawing -----------------------------------------------------------------------------------2 II. Technical Parameters ------------------------------------------------------------------------------2

More information

ELECTRIC METERING COMMERCIAL & INDUSTRIAL

ELECTRIC METERING COMMERCIAL & INDUSTRIAL ELECTRIC METERING COMMERCIAL & 1.0 INDEX 1.0 INDEX 2.0 SCOPE 3.0 GENERAL REQUIREMENTS 4.0 METER LOCATIONS 5.0 UNDERGROUND TERMINATIONS 6.0 METERING TRANSFORMER ENCLOSURES 7.0 SINGLE CUSTOMER METER INSTALLATIONS

More information

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH Amphenol C 091 A/B/D Circular Connectors Amphenol-Tuchel Electronics GmbH C 091 A Main Features Metal threaded coupling acc. to IEC. Number of contacts are 2 to 8, 12 and 14. Internal metal strain relief

More information

60.12. Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING

60.12. Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING 60.1 D-O-L FxE expansion couplings are a bolted, split-sleeve design that provides for expansion and contraction at the coupled joint. These couplings are furnished with restraint rings that, when affixed

More information

Guidelines for Earthquake Bracing of Residential Water Heaters

Guidelines for Earthquake Bracing of Residential Water Heaters Guidelines for Earthquake Bracing of Residential Water Heaters Department of General Services Division of the State Architect 1102 Q Street, Suite 5100 Sacramento, CA 95814 Phone: (916) 324-7099 Fax: (916)

More information

Cable Accessories. for Extruded Dielectric Cable 69kV - 230kV Rated. Catalog Python13

Cable Accessories. for Extruded Dielectric Cable 69kV - 230kV Rated. Catalog Python13 Cable Accessories for Extruded Dielectric Cable 69kV - 230kV Rated Components used in cable systems 100% Tested Factory Molded For outdoor applications through 230kV For gas insulated substations and transformers

More information

MCR1900 Media Converter 19-Slot Chassis

MCR1900 Media Converter 19-Slot Chassis MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the

More information

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC) APPLICATIONS Process Industry Weak Acids Alkalies Compressed Air Pulp & Paper MODELS ASM - Flanged Connection OPTIONS Control Rods Oil & Gas Water & Waste Pump suction & discharge Sea water Chemical lines

More information

14 PHOENIX CONTACT Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108. info@powermation.com - 800-843-9859 - www.powermation.

14 PHOENIX CONTACT Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108. info@powermation.com - 800-843-9859 - www.powermation. 14 PHOENIX CONTACT PLUSCON circular is a circular connector for use in industrial automation. The range of design sizes available is varied, starting with the design sizes M5 to M8 and M1, for sensor/actuator

More information

FullAXS CONNECTOR SEALING & CABLE ASSEMBLY

FullAXS CONNECTOR SEALING & CABLE ASSEMBLY FullAXS CONNECTOR SEALING & CABLE ASSEMBLY System Solution Guide Next Generation x-tta Solution Next generation WiMAX and Long Term Evolution (LTE) Fiber/Power/Signal To The Antenna (x-tta) connectivity

More information

HOSE, TUBE, AND PIPE CLAMPS

HOSE, TUBE, AND PIPE CLAMPS hose, tube & clamp B/W pages 24/6/08 9:28 AM Page 2 HOSE, TUBE, AND PIPE CLAMPS TABLE OF CONTENTS Introduction 3 Construction 3 Application 3 Mounting 3 Standard Duty Clamps (HRL) Arrangements 4 Dimensions

More information

Cables. Accessories. For Force, Torque and Strain Sensors

Cables. Accessories. For Force, Torque and Strain Sensors Accessories Cables For Force, Torque and Strain Sensors Charge mode, high impedance piezoelectric measurement demands highly insulated coaxial cables and connectors to ensure an insulation resistance greater

More information

Electrical Safety Products

Electrical Safety Products Electrical Safety Products Trelleborg Electrical Safety Products A safe working environment is important in all industries, but in the electrical generation and supply industry, it is paramount. Trelleborg

More information