LSOH Flexible Cables

Similar documents
FIRE RESISTANT CABLES FP200 GOLD

AFUMEX LSX LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 BASEC APPROVED PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:

VIPERFLEX ELECTRIC CABLE

The Quality Connection. BETAflam Fire Resistant Safety Cables

Airdac CNE and SNE, 600/1000V, Polyethylene Sheath, SANS 1507, NRS 063 & NRS 017

FIRE RESISTANT CABLE CONSTRUCTION OF CABLES

Tri-Rated Flexible PVC Equipment Wire

CONFLEX ELECTRIC CABLE

Fire Resistant Cables

Building Cables and Wires

Global cable expertise for rolling stock

Contents. All Rights Reserved

We specialize in low voltage cables including: Stranded Single Cable H07V-R Flexible Single Cable H05V-K

EDS KV TRIPLEX CABLE

CURRENT RATINGS MORE THAN A CABLE

Gulf Cable & Electrical Ind. Co.

BETAtrans. Cables and Systems for Rolling Stock. Edition 2006

CABLES FOR PHOTOVOLTAIC SOLAR ENERGY INSTALLATIONS FOR CLEAN ENERGY

RADOX railway cables acc. to EN and EN Edition 2009

INTERNATIONAL STANDARD

Requirements for Modular Patch Cords (e.g. RJ45 patch cords for Cat5 and Cat6 cabling systems)

LEAD FREE FIREX. Interlock Armored Cables TECK90 and MC Industrial Cables. w w w. n e x a n s e n e r g y. c o m

BRÖCKSKES D-VIERSEN PV1-F 4,0 mm BRÖCKSKES D-VIERSEN PV1-F 4,0 mm d d 2 2 C VDE-REG.-Nr /2009

KNOW YOUR OPTIONS: 230 KV POWER CABLES

INTERNATIONAL STANDARD

Section kv Power Cables

ScottishPower Distribution Cables & Equipment. Metal Theft

ENERGY. TECSUN DUO (PV) Twin Cables for Photovoltaics

ROLLING STOCK CABLES

ISO 9001 ISO CABLES AND WIRES CATALOGUE 2008

KNOW YOUR OPTIONS: 69 KV XLPE POWER CABLE

Removal of EP SP High Voltage Cable

MEDIUM VOLTAGE CABLES Up to and including 36 KV

3.6/6 kv XLPE insulated cables 5. 6/10 kv XLPE insulated cables /15 kv XLPE insulated cables /20 kv XLPE insulated cables 35

Gulf Cable & Electrical Ind. Co.

UGVCL/SP/591/11KV HT AB CABLE

Power and Wiring Cables

CLEVELAND CABLE LOCATIONS

MV CABLE TYPE C

Festoon 715 P PUR cable for flexible application in festoon systems

DOMESTIC ELECTRICAL INSTALLATION CERTIFICATE (Requirements for Electrical Installations BS 7671 IEE Wiring Regulations)

Specializing in the cable business for over 38 years, PT. SUPREME CABLE

ENERGY. TECWATER S1BN8-F 0,6/1 kv. Cable for Water Application

Corporate Profile ROYAL. MODERN ROYAL ELECTRIC Ideal Power Solution MRE ELECTRICAL, INSTRUMENTATION & COMMUNICATION SYSTEMS

APR 2016 Rev M

VDE-approved PVC-Control Cables

Cables, Cable Laying & Accessories Manual

TECHNICAL SPECIFICATION

PROFIBUS cable. PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications

Technical cable guide

The Handbook 2013 EDITION

Standard Buccaneer - Ethernet

UNDERSTANDING. C&M Corporation 51 South Walnut Street, Wauregan, CT Phone: Fax:

6000 Series Buccaneer

RAIL /// WIRE & CABLE WHERE THE BEST IDEAS IN RAIL BEGIN

SCHEDULE ' A ' TECHNICAL SPECIFICATION FOR SINGLE CORE,UNARMOURED L.T.XLPE POWER CABLE FOR DISTRIBUTION NETWORK IN MAHARASHTRA

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

Digital input modules

Flexible Control Cables

FLEXIBLE INDUSTRIAL CABLES H07RN-F TENAFLEX SR

ALARMLINE ANALOGUE Linear Heat Detection System

Chemical resistance Accidental

Flexible cables for submersible products

I-PEX MHF4 Micro Coaxial Connector

< SD 200 C TP Continuously flexible TPE/PUR paired data cable with coloured cores and overall copper screen... 10

with coloured cores and overall copper screen UL/CSA... 17

Flygt flexible cables

High Voltage Systems. Today. The history of cables

Important Information: Complete Terms and Conditions are printed on sales invoices

VOLTS - Copper conductor PVC insulated SSA 1320, IEC & BS 6004 HO 7V - U With Solid Conductor - TYPE IEC 01. Insulation Thickness

Blown Fibre Tube Cable Connectivity

Communication, Signal & Data Cables

e-mobility Special cables for electric vehicles Coroplast Fritz Müller GmbH & Co. KG Tapes Cables Cable Assemblies

Explosion proof enclosures

Type XHHW-2 or RHH/RHW-2/USE-2 GenFree II LSZH XLPO Single Conductor

SCHEDULE ' A' TECHNICAL SPECIFICATION FOR 11/22/33KV H.T.XLPE POWER CABLE FOR DISTRIBUTION NETWORK IN MAHARASHTRA (SPECIFICATION NO.

6 ELECTRICAL PARAMETERS

Flexible Cables and Cords

T A B L E T 1 T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A

Coaxial Cables for Medium-Frequency Applications

Flexible and safe solutions, for decades. Cables for alarmand safety systems

Fire Performance Standard

Gexol. Gexol. The Global Cable Solutions Company. Designed for safe, reliable performance in the harshest oil and gas operating environments

PROFIBUS cable. for PROFIBUS-PA and -DP 10/ EN

Electrical Safety Products

Commercial Coaxial Cable

PVC Insulated Mains Cable

1-085 Fire safety performance of materials

COAX Cables Radio Frequency Cables

MEDIUM VOLTAGE POWER CABLES

FOREWORD ONE OF THE WORLD S BIGGEST COMPANIES IN THE SECTOR.

Instrumentation Cable Power Cable Assembly Solutions...32

Current Ratings. TABLE BEC 107. (Continued) Current ratings for 6350/11000 volts grade PILC/SWA/PVC cable to BS6480/69

Automotive Wire and Cable Products

REPLACEMENT AIR CONDITIONING UNITS FOR BRITISH EMBASSY RESIDENCE

Fire retardant IEC

PFT Solutions. Fluid Filled Cable Leak Detection

Height w/o Terminals (in)

Allweather and Rubber Cables

Series 8146/5-V37 and Series 8150/5-V37

Transcription:

LSOH Flexible Cables Low Voltage (300/500 V) 3182B, 3183B, 3184B Piresafe TM Flex Cable Approvals Key Applications > Supply leads for medium duty domestic and office appliances, lighting fittings and portable appliances. Used in a wide range of public access buildings and industrial complexes where improved public safety and environmental control are desirable Key Features > Piresafe Flex is a flexible cable, which when burnt produces very low quantities of smoke and virtually no acidic gases thus safeguarding human life and protecting equipment > All Prysmian cables are manufactured under an ISO 9001 Quality System certified by BASEC Conductor > Plain annealed copper, flexible stranded circular conductor, complying with BS EN 60228 Class 5 Insulation > LSOH insulation Core Identification oo blue-brown oo blue-brown-green/yellow ooo brown-black-grey-green/yellow Sheath > Flexible LSOH sheath > Colour - Normally white but other colours are available on request Temperature Range -15 to +70 C Bending Radius Fixed r=4d Flexing r=6d Mechanical Impact Medium Fire Performance BSEN60332-1-2 Flexibility Flexible Halogen Free BSEN50267-2-1 Low smoke emissions BSEN50268-2 ref: PFLX/05/06 Prysmian Cables & Systems Limited, Sales Office, Chickenhall Lane, Eastleigh, Hants, SO50 6YU, UK Commercial Enquiries, Tel +44 (0) 8457 678 345, Fax: +44 (0) 23 8029 5465 www.prysmian.co.uk

Piresafe TM Flex Cable Details Nominal cross sectional area Conceptual construction Approximate conductor diameter Nominal overall diameter Approximate cable weight Minimum bending radius (Flexing) Maximum conductor resistance at 20 C Current rating DC or single phase AC Volt drop DC or single phase AC Current rating three phase AC Volt drop three phase AC mm² no./mm mm² mm kg/km mm ohms/km Amps mv/a/m Amps mv/a/m Two Core 0.75 24/0.20 1.14 6.2 59 40 26.0 6 62 - - 1.0 32/0.20 1.32 6.6 67 40 19.5 10 46 - - 1.5 30/0.25 1.6 7.6 90 45 13.3 16 32 - - 2.5 50/0.25 2.05 9.1 141 55 7.98 25 19 - - Three Core 0.75 24/0.20 1.14 6.6 69 40 26.0 6 62 - - 1.0 32/0.20 1.32 7 80 45 19.5 10 46 - - 1.5 30/0.25 1.6 8.2 113 50 13.3 16 32 - - 2.5 50/0.25 2.05 9.8 176 60 7.98 25 19 - - Four Core 0.75 24/0.20 1.14 7.0 83 45 26.0 6 62 6 54 1.0 32/0.20 1.32 7.8 101 50 19.5 10 46 10 40 1.5 30/0.25 1.6 9.2 141 55 13.3 16 32 16 27 2.5 50/0.25 2.05 10.8 214 80 7.98 25 19 20 16 Temperature rating factors Ambient Temperature C 30 35 40 45 50 55 Rating factor 1.00 0.91 0.82 0.71 0.58 0.41 Ref: PFLX/05/06 Prysmian Cables & Systems Limited, Sales Office, Chickenhall Lane, Eastleigh, Hants, SO50 6YU, UK Commercial Enquiries, Tel +44 (0) 8457 678 345, Fax: +44 (0) 23 8029 5465 www.prysmian.co.uk

ENERGY CABLES PO BOX 23, Chickenhall Lane EASTLEIGH SO50 6YU HAMPSHIRE Telephone: 023 80295989 Fax: 023 805295971 SCD QUALITY PLAN No. E\Q\208\PIRESAFE PIRESAFE FLEXIBLE CABLE QUALITY PLAN FOR FLEXIBLE CABLES HAVING LOW EMISSION OF SMOKE AND CORROSIVE GASES WHEN AFFECTED BY FIRE. FORWARD THIS QUALITY PLAN DETAILS THE TEST REQUIREMENTS FOR A RANGE OF CABLES FOR ELECTRIC POWER AND LIGHTING WHICH ARE FLEXIBLE, AND EMIT VERY LOW LEVELS OF SMOKE AND CORROSIVE GASES WHEN AFFECTED BY FIRE. THE IMPROVED PERFORMANCE UNDER FIRE CONDITIONS IS ASSESSED ON THE BASIS OF TESTS WHICH MEASURE THE EMISSION OF SMOKE AND CORROSIVE GASES AND FLAME PROPAGATION UNDER DEFINED CONDITIONS. THE CABLES ARE INTENDED FOR USE AS ORDINARY DUTY FLEXIBLE CABLE. THE CABLES ARE RATED AT 300/500V DESCRIPTION PLAIN COPPER CONDUCTORS XLPE INSULATED, TWISTED, LSOH FILLED AND SHEATHED. SPECIFICATIONS PIRESAFE FLEX MACHINE ROUTING 8110 / 8030 INSULATION 8041 LAY UP 8030 FINAL SHEATH 8078 / 79 CABLE COILING QAD FINAL TEST Pirelli Issue Status Issue Compiled Date Reason For Issue 1 J.Barstow May 2004 Draft for approval. Approved By: Agreed By:...... [Quality Engineer, Special Cables] [Manufacturing Manager, Special Cables] DISTRIBUTION: QUALITY ENGINEER - SPECIAL CABLES. TEST SECTION - SPECIAL CABLES. 1 ORIGINAL. 1

Quality Plan No : E\Q\208\PIRESAFE Issue: Number 1. Date: May 2004. QUALITY PLAN FOR MANUFACTURE, INSPECTION AND TEST Scope: Flexible cables of rated voltage 300/500V, which when assessed by tests specified in this Standard, produce low levels of smoke and corrosive products under exposure to fire. The cables are suitable for operation at a maximum sustained conductor temperature of 70 C. Specifications: PIRESAFE FLEX Customer Surveillance : H - Hold 1 - W - Witness 2 - R - Review 3 - C- Copy of Document Required Act. Freq. / Sample Test Method / Acceptance Acceptance Record Surveillance No. Stage Activity Sample By Procedure Criteria Authority Document 1 2 3 1.0 Design Design Review 100 % Design Engineer E\E\701 Design conforms to specification and customer requirements. Design Engineer Manufacturing Detail 2.0 Material Verification of Material. 100 % Buying & Stores PU-UK-03 & E\E\600-4 In accordance with Pirelli Approved Materials / Supplier list. Buyer & Stores Purchase Order 3.0 Conductor Manufacture ( 0.75 4.0mm 2 ) 3.1 Purchased Plain annealed copper strand. 100% Buying/ Stores BS6360 BS6360 Class 5. Buyer/ Stores Purchase Order 4.0 Insulation Manufacture 4.1 8110 Insulation Line Green/Yellow 1 in 3 Operator PI 8000 367 PI 8000 367 Operator Machine Insulation Thickness + 1 st off Database Diameter After input PI 8000 386 PI 8000 386 Conductor Resistance Change Spark Test 100 % Manufacturing Detail Manufacturing Detail Marking Cable Flaking Visual Visual Operator Machine Wet Ends Check Database 4.2 8030 Insulation Line All other colours 1 in 3 Operator PI 8000 367 PI 8000 367 Operator Machine Insulation Thickness + 1 st off Database Diameter After input PI 8000 386 PI 8000 386 Conductor Resistance <=25mm 2 Change Spark Test 100 % Manufacturing Detail Manufacturing Detail Marking Cable Flaking Visual Visual Wet Ends Check 5.0 Lay-Up Manufacture 5.1 8041 Godderidge Double Twist Laying-up Machine Conductor Resistance 100 % Operator PI 8000 386 PI 8000 386 Operator Machine Spark Test Manufacturing Detail Manufacturing Detail Database Lay Length / Direction Tension of Input Cores Core Rotation (Colour / Number) Cable Diameter 2

Quality Plan No : E\Q\208\PIRESAFE Issue: Number 1. Date: May 2004. QUALITY PLAN FOR MANUFACTURE, INSPECTION AND TEST Scope: Flexible cables of rated voltage 300/500V, which when assessed by tests specified in this Standard, produce low levels of smoke and corrosive products under exposure to fire. The cables are suitable for operation at a maximum sustained conductor temperature of 70 C. Specifications: PIRESAFE FLEX Customer Surveillance : H - Hold 1 - W - Witness 2 - R - Review 3 - C- Copy of Document Required Act. Freq. / Sample Test Method / Acceptance Acceptance Record Surveillance No. Stage Activity Sample By Procedure Criteria Authority Document 1 2 3 Cable Flaking Visual Visual 6.0 Final Sheath Manufacture 6.0 8030 Insulation Line All other colours 1 in 3 Operator PI 8000 367 PI 8000 367 Operator Machine Insulation Thickness + 1 st off Database Diameter After input PI 8000 386 PI 8000 386 Conductor Resistance <=25mm 2 Change Spark Test 100 % Manufacturing Detail Manufacturing Detail Marking Cable Flaking Visual Visual Wet Ends Check 7.0 Packing Manufacture 7.1 8078 Coiling Machine Spark Test 100 % Operator Manufacturing Detail Manufacturing Detail Operator Machine Lump / Neck down PI 8078-459 PI 8078-459 Database Cable Labelling Visual Visual Insulation / Sheath Application Cable Winding Cable Marking Manufacturing Detail Manufacturing Detail 7.2 8079 Coiling Machine Spark Test 100 % Operator Manufacturing Detail Manufacturing Detail Operator Machine Lump / Neck down PI 8079-459 PI 8079-459 Database Cable Labelling Visual Visual Insulation / Sheath Application Cable Winding Cable Marking Manufacturing Detail Manufacturing Detail 8.0 Final Test PIRESAFE 8.1 Routine Test Cable Marking 100 % Test Section Visual and Measurement Piresafe flex clause 9.1 Test Test Sheet Conductor Resistance BS6360 Class 2 BS6360 Class 2 Section Voltage test on complete cable Piresafe Clause 12.2 2000v for 5 minutes Core Identification Visual Piresafe Clause 6 Overall Diameter BSEN 60811-1-1 Piresafe Clause 13.4 8.2 Sample Test Insulation Thickness One Test Section Piresafe Clause 5.3 Piresafe Clause 5.3 & BSEN 60811 Test Test Sheet Per Test Section 3

Quality Plan No : E\Q\208\PIRESAFE Issue: Number 1. Date: May 2004. QUALITY PLAN FOR MANUFACTURE, INSPECTION AND TEST Scope: Flexible cables of rated voltage 300/500V, which when assessed by tests specified in this Standard, produce low levels of smoke and corrosive products under exposure to fire. The cables are suitable for operation at a maximum sustained conductor temperature of 70 C. Specifications: PIRESAFE FLEX Customer Surveillance : H - Hold 1 - W - Witness 2 - R - Review 3 - C- Copy of Document Required Act. Freq. / Sample Test Method / Acceptance Acceptance Record Surveillance No. Stage Activity Sample By Procedure Criteria Authority Document 1 2 3 Ovality Sheet Piresafe Clause 13.5 Piresafe 13.5 15% max Test Test Sheet Application Piresafe Clause 5.2 Visual examination Section Final Sheath Thickness Piresafe Clause 8.3 Piresafe Clause 13 & BSEN 60811 Voltage test on complete cable Annually Piresafe Clause 13.6 Piresafe Clause 13.6 Voltage test on cores Piresafe Clause 13.7 Piresafe Clause 13.7 Insulation Resistance Piresafe Clause 13.8 Piresafe Clause 13.8 Final Sheath Thickness Piresafe Clause 8.3 Piresafe Clause 13 & BSEN 60811 Single Wire Propagation Test Annually FTL Piresafe Clause 13.11 BSEN 50265-2-1 Smoke Emission Piresafe Clause 13.1 BSEN 50268-2 8.3 Type Test Insulation Material Contract Test Section Test Test Sheet Two pulley flex test Specific Or Section Compatibility Significant Piresafe Clause 5.1 Piresafe Clause 5.1/ 14.3 & BS7211 annex D Corrosive and Acid Gas on Product BSEN50267-2-1 Piresafe Clause 5.5: HCI level 0.5% maximum Insulation changes Final Sheath Physicals Piresafe Clause 8.1 Piresafe Table 1 & BS EN 60811 Corrosive and Acid Gas on BSEN50267-2-1 Piresafe Clause 5.5 HCI level 0.5% maximum Insulation Corrosive and Acid Gas on Oversheath BSEN50267-2-1 Piresafe Clause 8.4 HCI level 0.5% maximum 4