proficonn-dsub proficonn-dip28 PROFIBUS-DP Slave Interface Modules proficonn proficonn

Similar documents
PROFIBUS cable. for PROFIBUS-PA and -DP 10/ EN

PROFIBUS cable. PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications

UNITRONIC Data Communication Systems

Communication, Signal & Data Cables

HARTING Ethernet Cabling 8-poles Overview

HARTING Ethernet Cabling 4-poles Overview

ETHERLINE Ethernet Cable, Connectors & Tools

HARTING Ethernet Cabling 4-poles Overview

with coloured cores and overall copper screen UL/CSA... 17

Standard Buccaneer - Ethernet

CAVEL VS80205 MADE IN ITALY 1000 V

COAX Cables Radio Frequency Cables

HARAX circular connector

Flexible Control Cables

DATA SHEET SERVO LK SMS FX8PLUS SIGNAL

CABLE SPECIFICATION CAN CAB RJ45-SUBD9

Cable Guide. Cables, Connectors & Tools for installation of quality networks. TRIAX - your ultimate connection

6000 Series Buccaneer

Specification SFTP CAT6 Network Cable 23AWG CU

Digital input modules

Gulf Cable & Electrical Ind. Co.

HARTING econ 3000 Introduction and features

Rutenbeck Network Connection Box Cat. 5, shielded. Cable installation. UAE Connection Box Cat. 5 Operating Instructions.

Bare copper complying with CEI EN (CEI 20-29) class 1. Foam PE with HDPE skin. Core colours: green and red

Tri-Rated Flexible PVC Equipment Wire

Outside Telephone Cable

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

Festoon 715 P PUR cable for flexible application in festoon systems

FN2001-A1 Network module (SAFEDLINK) Mounting Installation

< SD 200 C TP Continuously flexible TPE/PUR paired data cable with coloured cores and overall copper screen... 10

Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System

Modular I/O System Analog and Digital Interface Modules

400 Series - Mini USB Buccaneer

Cable Solutions for Servo and Variable Frequency Drives (VFD)

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Standards Affecting a Premise T-1 Installation

IMVIB. Online vibration monitoring for Ariel compressors

TX OPEN RS232/485 module

CONFLEX ELECTRIC CABLE

Fieldbus slave modules with I/Os, DIO

TFC/U-JIN Coaxial Cable Product Information Sheet Type: TU6T60-JVB

01. HARTING RJ INDUSTRIAL RJ45 ETHERNET CONNECTORS

EVOline Multimedia Modules

1394 locking cables. Your locking cables for AVT IEEE 1394 cameras

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

GE Power Controls FIELDBUS APPENDIX PROFIBUS DP. Doc. No.: ASTAT Plus PB_Appendix-v0

Telephone- and leased line modem for industrial applications TD-36

Ten Port Multi-Band Antenna

Rack mounted telephone- and leased line modem for industrial applications

6000 Series Buccaneer. 30 twist locking Tamperproof lock prevents accidental un-mating. Cat 5e shielded coupler Maintains shielding

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

PCAN-B10011S Bus Converter High-speed CAN to Truck Trailer CAN. User Manual. Document version ( )

Table of contents. Page. General information. Why BUS Systems? Field BUS DESINA. Bus Types and Sensor Bus. AS-Interface Bus 1. Interbus 3.

Manual Serial PCI Cards

E Series. E Series. Category 6 and 5e. Features

MV CABLE TYPE C

Coaxial cables? Video cables Loudspeaker cables

The Quality Connection. Cable Solutions for Mobile Networks Business Unit Telecom

Mini USB and USB 2.0-IP67 Connector System

WHITEPAPER. Cable and Connector for Hiperface dsl motor drive applications

Extract from the online catalog

Commercial Coaxial Cable

RoHS DATA, COAXIAL AND ELECTRONIC M.R. D A TA, C O A X I A L, ECOLGICAL Telecom Cables A N D EL E CTRON I C. Cables

MacArtney Underwater Cables - In stock

Signaling Lights. LH Series Surface Mount Indicators. Part Numbers. Jumbo Dome (one color) Jumbo Dome (two color)

Series 8146/5-V37 and Series 8150/5-V37

ABB Drives. User s Manual HTL Encoder Interface FEN-31

MICRO SFP+ CONNECTOR & CABLE ASSEMBLY

PCS0100en Persy Control Services B.V. Netherlands

Product Information. HMC 6 Hybrid Motor Cable

Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty Safety notes Policy Warranty.

Directory chapter 04

CAN - Wiring Notes on the Wiring of CAN-Bus Systems and the Cable Selection

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

VDE-approved PVC-Control Cables

08. SEK IDC CONNECTORS

Installation Manual (English) Adjustable Active DP Terminator T1-Pepper Active RS485 segment termination for non-compliant cable

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

The Quality Connection. Cables for Data Transmission in Industrial Automation

Servo Motor & Drive Cables

Practical steps for a successful. PROFIBUS Project. Presented by Dr. Xiu Ji Manchester Metropolitan University

BUS 1010F Cavo per posa fissa (INTERBUS Remote Bus, 2-wire) INTERBUS cable for fixed installation

R&Mfreenet Advanced Cat 6 A Unshielded Connection Module

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

SICK AG WHITEPAPER. Information for cable manufacturers Note-2_03

MICROCABLES. A complete vision of your connectivity needs. Catalogue

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no

maxon motor maxon motor control EPOS Positioning Controller Cable Starting Set Edition June 2006 part number Positioning Controller

EcoFlex Cable. Smaller. Lighter. Tougher. 100% Recyclable.

FIBER OPTIC APPLICATION IN A PROFIBUS NETWORK

Quality Reliability Innovation. ISO 9001 : 2000 CERTIFIED BY AFAQ No. QUAL / 1997 / 7034 a COPPER TELECOMMUNICATION CABLES

IP 20 B.1 8 IP 65 / IP 67 B Cables B Tools B IP 20 B.2 8 IP 65 / IP 67 B Cables B Tools B IP 20 B.

14 PHOENIX CONTACT Courtesy of Power/mation Energy Lane, Saint Paul, MN

mpm DIN CONNECTORS

Provides one channel for Ethernet over existing

PRODUCT SPECIFICATION

M-Bus Network Installation Notes

Hardware Manual RM CANview Ethernet

FLEXIBLE INDUSTRIAL CABLES H07RN-F TENAFLEX SR

Options for ABB drives, converters and inverters. User s manual FDPI-02 diagnostics and panel interface

Transcription:

proficonn-dsub proficonn-dip28 PROFIBUS-DP Slave Interface Modules proficonn proficonn SPI interface (up to 6 MBit/s) Isolated RS485 Interface up to 12 MBit/s Status LEDs for Power and DataExchange Vcc 3.3V Supporting PROFIBUS-DP-V0, DP-V1 and DP-V2 4kB communication RAM Software stack proficonn-dsub With 9-pin DSUB-connector for direct enclosure mounting Flat cable connector for SPI communication and power supply Dimensions: 58 x 31 x 16 mm proficonn-dip28 28 pin Dual-Inline-Package format for mounting on PCB via standard IC socket Dimensions: 36 x 18 x 10 mm

Overview proficonn-dsub and proficonn-dip28 are very compact PROFIBUS-DP slave interface modules based on profichip`s VPC3+S protocol ASIC. Both modules provide a complete, PROFIBUS approved RS485 interface including DC/DC converter and isolated line driver. Efficient and signal saving communication with the costumer application is accomplished by means of a serial SPI channel. For more details please refer to the VPC3+S User Manual. proficonn DIP28 The proficonn-dip28 module is based on a standard DIP28 footprint. The module can be mounted on the PCB directly or plugged into a standard IC socket. proficonn DSUB The proficonn-dsub module is suited for direct enclosure mounting via shielded 9-pin DSUB female connector (X1). A 10-pin 2.54 mm male socket (X2) is provided to connect to the device electronic via flat ribbon cable. profichip GmbH Einsteinstr. 6 D-91074 Herzogenaurach Germany Phone: +49 9132 744-2161 Fax: +49 9132 744-2164 E-Mail: info@profi chip.com www.profichip.com Date: 02/2012 EK004053

EasyConn PB Profibus Connector EasyConn PB: The bus connector EasyConn PB is used for the connection of Profibus participants to the bus line. The fully visible diagnostic LEDs facilitate the installation considerably. Users can immediately check the status of bus activity, termination resistors, power supply and bus status. The integrated controller supports transmission rate of up to 12MBit/s. Features: Cable slots with transparent covers for high visibility (wiring, position of sreen and cable) Full metal construction for noise immunity and harsh environment State monitoring via integrated LEDs for bus diagnosis Comfortable IDC technology for fast and reliable wire connection Captive singe-screw-mounting system - no loose parts Integrated switchable termination resistor Integrated programming / diagnostic port Supporting stranded wire types: LAPP Art. No. 2170222, 2170822, 2170322 Standard bus line for fixed and flexible wiring Features: Bus line according to DIN 19245 and EN 50170 Two wires stranded (Red/Green) Sheathing PVC mixture (violet, RAL4001) Flame-retardant according to VDE 0472, part 804, Test procedure B (IEC 332.1) Use of stranded wire (Lapp Cable Art. No. 2170222, 2170822, 2170322)

Wiring diagramm - Connector 90 Insulation Stripping 11 6 PA003135-90 PA003121-45 PA003122-0 Technical Data EasyConn PB Connections Profibus 9pole SubD pin headers PG/diagnostics Insertion (withdraw.) cycle Cable diameter Fixing screws/max. tightening torque 9pole SubD socket* mind. 200 8mm 4-40 UNC/0.4Nm Enclosure Material die-cast zinc Protection IP 20 Voltage supply DC 4.75 bis 5.25 V (Supply comes from the terminal max. 30mA) Power input max. 30mA Temperature range -20 C bis +75 C Insulation stripping lengths incomming bus line outgoing bus line Outer sheath 17mm 17mm Shield 11mm 11mm Connection technology IDC technology Bus line fixed wire Type A (EN 50 170) stranded wire (f. Lapp) Type A (EN 50 170) Linear expansion Transmission speed in kbit/s max. segment lengths in m 9,6/19,2/45,45/93,75 1200 187,5 1000 500 400 1500 200 3000/6000/12000 100 Name Color LED off LED on LED blinking (5Hz) PWR green No Power (<4V) Self-test finished, Power OK Short-circuit of bus wire possible. (4 5,5V) Blinks simultaneously with ERR LED. TXD green No bus activity - Data transfer active Term green No termination Termination active Internal terminating resistor faulty. Blinks simultaneously with ERR LED. ERR yellow No errors detected Signal levels out of defined Short-circuit of bus wire range, possibly termination failure possible respectively internal in bus line. resistor faulty. The LED flashes sporadically/asymmetrically: The Profibus device is near the reference level, which is defined in the Profibus connector. Appearing differences were compensated by the protocol. Standard bus line Flame retardant VDE 0472, Teil 804 Test procedure B (IEC332.1) Pair number/wire diameter 1x2x0.64mm External diameter 7.8mm Copper number 26kg/km Weight ca. 57kg/km Surge impedance 150 ±15 Op. capacitance (800 Hz) max.30nf/km Operating peak voltage 250V (not for heavy current usage) Test voltage core/core Ueff 1500V Wire resistance (loop) max.110 /km Mind. bend radius 75mm Temperature range -40 C bis +70 C Ordering information EasyConn PB 90 PA003135 EasyConn PB 45 EasyConn PB 0 Bus line (25m to 1000m) EasyStrip (Stripping tool) PA003125 (without integrated diagnosis) PA003121 PA003122 PA00315x PA003160 Date of Issue: 02 2010 * at EasyConn PB 90, 45

Technical Data Sheet Profibus-Cable System Interface Bare copper wire (22 AWG) Insulation of foamed Polyethylen (PE) with skin System Interface 2 wires, RD and GN twisted to a pair with fi llers in gaps Alulaminate foil overlapped, Alu outside Shield braiding of tinned copper wires 0.15 mm dia Coverage about 55% Slitting cord under jacket Jacket Polyvinylchloride (PVC) VT Wall thickness about 1.0 mm Ø 0,65 mm Ø 2,55 mm ø (8.0 ±0.4) mm Printing: sequential length in metres profi chip PROFIBUS PLUS L2 * 22AWG (SHIELDED) (UL) E119100, CMG 75 C or PLTC or AWM 20201 600V FT4 SUN RES * internal lot number Textintervals about 1000 mm Electrical data at 20 C Loop resistance Insulation resistance Characteristic Impedance 110 Ohm/km 16000 MOhm*km 3-20 MHz (150 ± 15 ) Ohm 31.25-38.4 khz (185 ± 18.5) Ohm 9.6 khz (270 ± 27 ) Ohm Attenuation 16 MHz < 42 db/km 4 MHz < 22 db/km 38,4 MHz < 4 db/km 9,6 MHz < 2,5 db/km Inductance 31,25 khz Capacitance 1 khz Capacitance unbalance to ground Operating Voltage (Peak) UL-Rating Test voltage (50Hz, 1min) 750 µh/km 28 nf/km 1500 pf/km 100 V 600 V 2000 V DC

Mechanical and thermal characteristics Conductor material acc. to DIN EN 13602 Cu-ETP-A... Screen material acc. to DIN EN 13602 Cu-ETP-A...-B Insulating material acc. to DIN EN 50290-2-23 (VDE 0819), table 2/A (HD 624.3) Jacket material acc. to DIN EN 50290-2-22 (VDE 0819), compoundtype TM52 (HD 624.2) Cold bend test acc. DIN IEC 60811-1-4-40 C Flame retardant acc. to UL 1685 (CSA FT 4) UL-File E119100 Vol.1 Sec.16 Page 7 UL-File E116441 Vol.1 Sec.6 Page 7 UL-Style 20201 Other charateristics Limited mineral oil and fats resistance Flame retardant acc. to IEC 60332-3-24 (Cat. C) Sunlight resistant acc. to UL 1581 Sec.1200 Permissible temperature range -40 C up to + 80 C Bending Diameter 150 mm Pulling force with 100 N PVC weight with Phthalate PVC weight without Phthalate Weight about 32.1 kg/km 0.0 kg/km 63 kg/km Designation of order L45467-G 16-C425 L45467-G 16-C425-F2 L45467-G 16-C425-F4 L45467-G 16-C425-L6 1.000 meter on non-returnable reel 100 meter ring 200 meter ring 500 meter on non-returnable reel 02YS(ST)CY 1X2X0.64/2.55-150 VI KF40 FR profichip GmbH Einsteinstr. 6 D-91074 Herzogenaurach Germany Phone: +49 9132 744-2161 Fax: +49 9132 744-2164 E-Mail: info@profi chip.com www.profichip.com Date of Issue: 02 2010