Fieldbus slave modules with I/Os, DIO
|
|
- Caitlin Hampton
- 7 years ago
- Views:
Transcription
1 140 Fieldbus slave modules with I/Os, DIO 1534CF CH PF PH CH CL PH PL00 Order number 1534CF CH PF PH00 Figure Type SM 153, CANopen slave, DIO 8xDC 24V 1A, 2x11 clamps General information SM 153, CANopen slave, DI 8 (12)xDC 24V, DO 4(8)xDC 24V 1A SM 153, PBDP slave, DIO 8xDC 24V 1A, 2x11 clamps SM 153, PBDP slave, DI 8xDC 24V, DO 8xDC 24V 1A Note Features CAN slave, CAN slave, PROFIBUSDP slave, PROFIBUSDP slave, 8 channels as inputs or outputs, 2x11 clamps 8 (12) inputs, 4 (8) outputs 8 channels as inputs or outputs, 2x11 clamps 8 inputs, 8 outputs Technical data power supply Power supply (rated value) DC 24 V DC 24 V DC 24 V DC 24 V Power supply (permitted range) DC V DC V DC V DC V Reverse polarity protection Current consumption (noload operation) Current consumption (rated value) 55 ma 55 ma 55 ma 55 ma Inrush current I²t Max. current drain at backplane bus Max. current drain load supply Power loss Technical data digital inputs Number of inputs 0 (8) 8 (12) 0 (8) 8 (16) Cable length, shielded 1000 m 1000 m 1000 m 1000 m Cable length, unshielded 600 m 600 m 600 m 600 m Rated load DC 24 V DC 24 V DC 24 V DC 24 V Reverse polarity protection of rated load Current consumption from load L+ (without load) Rated value DC 24 V DC 24 V DC 24 V DC 24 V Input for signal "0" DC V DC V DC V DC V Input for signal "1" DC V DC V DC V DC V Input hysterese Frequency range Input resistance Input current for signal "1" Connection of TwoWireBEROs possible Max. permissible BERO quiescent current 1.5 ma 1.5 ma 1.5 ma 1.5 ma Input delay of "0" to "1" 3 ms 3 ms 3 ms 3 ms Input delay of "1" to "0" 3 ms 3 ms 3 ms 3 ms
2 1534CF CH PF PH CH CL PH PL00 Fieldbus slave modules with I/Os, DIO Interface modules Order number 1534CF CH PF PH00 Number of simultaneously utilizable inputs horizontal configuration Number of simultaneously utilizable inputs vertical configuration Input characteristic curve Initial data size 1 Byte 2 Byte 1 Byte 1 Byte Technical data digital outputs Number of outputs 8 (0) 8 (4) 8 (0) 8 (4) Cable length, shielded 1000 m 1000 m 1000 m 1000 m Cable length, unshielded 600 m 600 m 600 m 600 m Rated load DC 24 V DC 24 V DC 24 V DC 24 V Reverse polarity protection of rated load Current consumption from load L+ 50 ma 50 ma 50 ma 50 ma (without load) Total current per group, horizontal configuration, 40 C Total current per group, horizontal configuration, 60 C Total current per group, vertical configuration Output signal "1" at min. current L+ (0.8 V) L+ (0.8 V) L+ (0.8 V) L+ (0.8 V) Output signal "1" at max. current Output current at signal "1", rated value 1 A 1 A 1 A 1 A Output current, permitted range to 40 C Output current, permitted range to 60 C Output current at signal "0" max. (residual current) Output delay of "0" to "1" Output delay of "1" to "0" Minimum load current Lamp load Parallel switching of outputs for redundant control of a load Parallel switching of outputs for increased power Actuation of digital input Switching frequency with resistive load max Hz max Hz max Hz max Hz Switching frequency with inductive load max. 0.5 Hz max. 0.5 Hz max. 0.5 Hz max. 0.5 Hz Switching frequency on lamp load max. 10 Hz max. 10 Hz max. 10 Hz max. 10 Hz Internal limitation of inductive shutoff L+ (52 V) L+ (52 V) L+ (52 V) L+ (52 V) Shortcircuit protection of output yes, electronic yes, electronic yes, electronic yes, electronic Trigger level 1.5 A 1.5 A 1.5 A 1.5 A Number of operating cycle of relay outputs Switching capacity of contacts Output data size 1 Byte 1 Byte 1 Byte 1 Byte 141
3 CF CH PF PH CH CL PH PL00 Order number 1534CF CH PF PH00 Status information, alarms, diagnostics Status display green LED per channel green LED per channel green LED per channel green LED per channel Interrupts no no no no Process alarm no no no no Diagnostic interrupt no no no no Diagnostic functions no no no no Diagnostics information readout possible possible possible possible Supply display yes yes yes yes Group error display red SF LED red SF LED red SF LED red SF LED Channel error display none none none none Isolation Between channels Between channels of groups to Between channels and backplane bus Between channels and power supply Max. potential difference between circuits (Ucm) Max. potential difference between Mana and Mintern (Uiso) and Mana (Ucm) and Mintern (Uiso) Max. potential difference between Mintern and outputs Insulation tested with DC 500 V DC 500 V DC 500 V DC 500 V Hardware config Racks, max. Modules per rack, max. Number of digital modules, max. Number of analog modules, max. Communication Field bus CANopen CANopen PROFIBUSDP to EN PROFIBUSDP to EN Type of interface CAN CAN RS485 RS485 Connector SubD, 9pin, male SubD, 9pin, male SubD, 9pin, female SubD, 9pin, female Topology Electrically isolated Number of participants, max Node addresses Transmission speed, min. 10 kbit/s 10 kbit/s 9.6 kbit/s 9.6 kbit/s Transmission speed, max. 1 Mbit/s 1 Mbit/s 12 Mbit/s 12 Mbit/s Address range inputs, max. 1 Byte 2 Byte 1 Byte 1 Byte Address range outputs, max. 1 Byte 1 Byte 1 Byte 1 Byte Number of TxPDOs, max. 1 1 Number of RxPDOs, max. 1 1
4 1534CF CH PF PH CH CL PH PL00 Fieldbus slave modules with I/Os, DIO Interface modules Order number 1534CF CH PF PH00 Mechanical data Dimensions (WxHxD) mm x 76 mm x mm x 76 mm x mm x 76 mm x mm x 76 mm x Weight 219 g 216 g 221 g 220 g Environmental conditions Operating temperature 0 C to 60 C 0 C to 60 C 0 C to 60 C 0 C to 60 C Storage temperature 25 C to 70 C 25 C to 70 C 25 C to 70 C 25 C to 70 C Certifications UL508 certification yes yes yes yes 143
5 Connections, Interfaces 1534CF CH PF PH CF CH PF PH CH CL PH PL00 CAN CAN L+ L+ X4M X4M L+ L+ 144
6 1534CF CH PF PH CH CL PH PL00 Fieldbus slave modules with I/Os, DIO Order number 1536CH CL PH PL00 Figure Type SM 153, CANopen slave DI 8(12)xDC 24V, DO 4(8)xDC 24V 1A, 4x11 clamps General information SM 153, CANopen slave DI 24xDC 24V, DO 8xDC 24V 1A SM 153, PBDP slave, DI 8xDC 24V, DO 8xDC 1A, 4x11 clamps SM 153, PBDP slave DI 16xDC 24V, DO 16xDC 24V 1A Note Features CAN slave, CAN slave, PROFIBUSDP slave, PROFIBUSDP slave, 8 (12) inputs, 4 (8) outputs, 4x11 clamps 24 inputs, 8 outputs Fieldbus slave modules with I/Os, DIO Interface modules 8 inputs, 8 outputs, 4x11 clamps 16 inputs, 16 outputs Technical data power supply Power supply (rated value) DC 24 V DC 24 V DC 24 V DC 24 V Power supply (permitted range) DC V DC V DC V DC V Reverse polarity protection Current consumption (noload operation) Current consumption (rated value) 55 ma 55 ma 55 ma 55 ma Inrush current I²t Max. current drain at backplane bus Max. current drain load supply Power loss Technical data digital inputs Number of inputs 8 (12) Cable length, shielded 1000 m 1000 m 1000 m 1000 m Cable length, unshielded 600 m 600 m 600 m 600 m Rated load DC 24 V DC 24 V DC 24 V DC 24 V Reverse polarity protection of rated load Current consumption from load L+ (without load) Rated value DC 24 V DC 24 V DC 24 V DC 24 V Input for signal "0" DC V DC V DC V DC V Input for signal "1" DC V DC V DC V DC V Input hysterese Frequency range Input resistance Input current for signal "1" Connection of TwoWireBEROs possible Max. permissible BERO quiescent current 1.5 ma 1.5 ma 1.5 ma 1.5 ma Input delay of "0" to "1" 3 ms 3 ms 3 ms 3 ms 145
7 CF CH PF PH CH CL PH PL00 Fieldbus slave modules with I/Os, DIO Interface modules Order number 1536CH CL PH PL00 Input delay of "1" to "0" 3 ms 3 ms 3 ms 3 ms Number of simultaneously utilizable inputs horizontal configuration Number of simultaneously utilizable inputs vertical configuration Input characteristic curve Initial data size 2 Byte 3 Byte 1 Byte 2 Byte Technical data digital outputs Number of outputs 8 (4) Cable length, shielded 1000 m 1000 m 1000 m 1000 m Cable length, unshielded 600 m 600 m 600 m 600 m Rated load DC 24 V DC 24 V DC 24 V DC 24 V Reverse polarity protection of rated load Current consumption from load L+ 55 ma 55 ma 55 ma 55 ma (without load) Total current per group, horizontal configuration, 40 C Total current per group, horizontal configuration, 60 C Total current per group, vertical configuration Output signal "1" at min. current L+ (0.8 V) L+ (0.8 V) L+ (0.8 V) L+ (0.8 V) Output signal "1" at max. current Output current at signal "1", rated value 1 A 1 A 1 A 1 A Output current, permitted range to 40 C Output current, permitted range to 60 C Output current at signal "0" max. (residual current) Output delay of "0" to "1" Output delay of "1" to "0" Minimum load current Lamp load Parallel switching of outputs for redundant control of a load Parallel switching of outputs for increased power Actuation of digital input Switching frequency with resistive load Switching frequency with inductive load Switching frequency on lamp load Internal limitation of inductive shutoff Shortcircuit protection of output yes, electronic yes, electronic yes, electronic yes, electronic Trigger level 1.5 A 1.5 A 1.5 A 1.5 A Number of operating cycle of relay outputs Switching capacity of contacts Output data size 1 Byte 1 Byte 1 Byte 2 Byte
8 1534CF CH PF PH CH CL PH PL00 Order number 1536CH CL PH PL00 Status information, alarms, diagnostics Status display green LED per channel green LED per channel green LED per channel green LED per channel Interrupts no no no no Process alarm no no no no Diagnostic interrupt no no no no Diagnostic functions no no no no Diagnostics information readout possible possible possible possible Supply display yes yes yes yes Group error display red SF LED red SF LED red SF LED red SF LED Channel error display none none none none Isolation Between channels Between channels of groups to Between channels and backplane bus Between channels and power supply Max. potential difference between circuits (Ucm) Max. potential difference between Mana and Mintern (Uiso) and Mana (Ucm) and Mintern (Uiso) Max. potential difference between Mintern and outputs Insulation tested with DC 500 V DC 500 V DC 500 V DC 500 V Hardware config Racks, max. Modules per rack, max. Number of digital modules, max. Number of analog modules, max. Communication Field bus CANopen CANopen PROFIBUSDP to EN PROFIBUSDP to EN Type of interface CAN CAN RS485 RS485 Connector SubD, 9pin, male SubD, 9pin, male SubD, 9pin, female SubD, 9pin, female Topology Electrically isolated Number of participants, max Node addresses Transmission speed, min. 10 kbit/s 10 kbit/s 9.6 kbit/s 9.6 kbit/s Transmission speed, max. 1 Mbit/s 1 Mbit/s 12 Mbit/s 12 Mbit/s Address range inputs, max. 2 Byte 3 Byte 1 Byte 2 Byte Address range outputs, max. 1 Byte 1 Byte 1 Byte 2 Byte Number of TxPDOs, max. 1 1 Number of RxPDOs, max
9 1534CF CH PF PH CH CL PH PL00 Order number 1536CH CL PH PL00 Mechanical data Dimensions (WxHxD) mm x 76 mm x mm x 76 mm x mm x 76 mm x mm x 76 mm x Weight 266 g 311 g 268 g 264 g Environmental conditions Operating temperature 0 C to 60 C 0 C to 60 C 0 C to 60 C 0 C to 60 C Storage temperature 25 C to 70 C 25 C to 70 C 25 C to 70 C 25 C to 70 C Certifications UL508 certification yes yes yes yes 148
10 1534CF CH PF PH CH CL PH PL CH CL PH PL00 CAN CAN Fieldbus slave modules with I/Os, DIO Interface modules Connections, Interfaces L+ X4M X6M L+ L+ 149
11 Fieldbus slave modules with I/Os, DIO 1534CF CH PF PH00 Order number Figure 1536CH CL PH PL00 Type SM 153, PBDP slave, DI 24xDC 24V, DO 8xDC 24V 1A General information Note Features PROFIBUSDP slave, 24 inputs, 8 outputs Technical data power supply Power supply (rated value) DC 24 V Power supply (permitted range) DC V Reverse polarity protection Current consumption (noload operation) Current consumption (rated value) 55 ma Inrush current I²t Max. current drain at backplane bus Max. current drain load supply Power loss Technical data digital inputs Number of inputs 24 Cable length, shielded 1000 m Cable length, unshielded 600 m Rated load DC 24 V Reverse polarity protection of rated load Current consumption from load L+ (without load) Rated value DC 24 V Input for signal "0" DC V Input for signal "1" DC V Input hysterese Frequency range Input resistance Input current for signal "1" Connection of TwoWireBEROs possible Max. permissible BERO quiescent current 1.5 ma Input delay of "0" to "1" 3 ms Input delay of "1" to "0" 3 ms 150
12 1534CF CH PF PH CH CL PH PL00 Order number Number of simultaneously utilizable inputs horizontal configuration Number of simultaneously utilizable inputs vertical configuration Input characteristic curve Initial data size 3 Byte Technical data digital outputs Number of outputs 8 Cable length, shielded 1000 m Cable length, unshielded 600 m Rated load DC 24 V Reverse polarity protection of rated load Current consumption from load L+ 50 ma (without load) Total current per group, horizontal configuration, 40 C Total current per group, horizontal configuration, 60 C Total current per group, vertical configuration Output signal "1" at min. current L+ (0.8 V) Output signal "1" at max. current Output current at signal "1", rated value 1 A Output current, permitted range to 40 C Output current, permitted range to 60 C Output current at signal "0" max. (residual current) Output delay of "0" to "1" Output delay of "1" to "0" Minimum load current Lamp load Parallel switching of outputs for redundant control of a load Parallel switching of outputs for increased power Actuation of digital input Switching frequency with resistive load Switching frequency with inductive load Switching frequency on lamp load Internal limitation of inductive shutoff Shortcircuit protection of output yes, electronic Trigger level 1.5 A Number of operating cycle of relay outputs Switching capacity of contacts Output data size 1 Byte Fieldbus slave modules with I/Os, DIO Interface modules 151
13 CF CH PF PH CH CL PH PL00 Order number Status information, alarms, diagnostics Status display green LED per channel Interrupts no Process alarm no Diagnostic interrupt no Diagnostic functions no Diagnostics information readout possible Supply display yes Group error display red SF LED Channel error display none Isolation Between channels Between channels of groups to 8 Between channels and backplane bus Between channels and power supply Max. potential difference between circuits (Ucm) Max. potential difference between Mana and Mintern (Uiso) and Mana (Ucm) and Mintern (Uiso) Max. potential difference between Mintern and outputs Insulation tested with DC 500 V Hardware config Racks, max. Modules per rack, max. Number of digital modules, max. Number of analog modules, max. Communication Field bus PROFIBUSDP to EN Type of interface RS485 Connector SubD, 9pin, female Topology Electrically isolated Number of participants, max. 125 Node addresses 1 99 Transmission speed, min. 9.6 kbit/s Transmission speed, max. 12 Mbit/s Address range inputs, max. 3 Byte Address range outputs, max. 1 Byte Number of TxPDOs, max.
14 1534CF CH PF PH CH CL PH PL00 Order number Number of RxPDOs, max. Mechanical data Dimensions (WxHxD) mm x 76 mm x Weight 264 g Environmental conditions Operating temperature 0 C to 60 C Storage temperature 25 C to 70 C Certifications UL508 certification yes Fieldbus slave modules with I/Os, DIO Interface modules 153
15 Connections, Interfaces 1534CF CH PF PH CH CL PH PL00 L+ 154
6ES7313-5BF03-0AB0. Supply voltages Rated value 24 V DC Yes permissible range, upper limit (DC) circuit breaker type B, min. 4 A
6ES7313-5BF03-0AB0 Page 1 Product data sheet 6ES7313-5BF03-0AB0 SIMATIC S7-300, CPU 313C, COMPACT CPU WITH MPI, 24 DI/16 DO, 4AI, 2AO 1 PT100, 3 FAST COUNTERS (30 KHZ), INTEGRATED 24V DC POWER SUPPLY,
More information6ES7314-6CG03-0AB0. Supply voltages Rated value 24 V DC Yes permissible range, upper limit (DC) circuit breaker type B, min. 4 A
6ES7314-6CG03-0AB0 Page 1 Product data sheet 6ES7314-6CG03-0AB0 SIMATIC S7-300, CPU 314C-2DP COMPACT CPU WITH MPI, 24 DI/16 DO, 4AI, 2AO, 1 PT100, 4 FAST COUNTERS (60 KHZ), INTEGRATED DP INTERFACE, INTEGRATED
More informationData sheet SLIO CPU 015 (015-CEFPR00)
Data sheet SLIO CPU 015 (015-CEFPR00) Technical data Order no. 015-CEFPR00 SLIO CPU 015 Module ID - General information Note - Features SPEED7 technology 256 kb work memory Memory extension (max. 512 kb)
More informationProcess modules Digital input PMI for 24 V DC inputs for 120 V AC inputs
E031026 000823 Process modules Digital input PMI for inputs for 120 V AC inputs PMI Input E4, E5, GND L- PMI 120 V AC Input E4, E5, Common C E6, E7, GND L- E6, E7, Common C LEDs for the inputs operation
More informationSIMATIC. ET 200S distributed I/O Digital electronic module 8DO DC24V/0.5 A (6ES7132-4BF00-0AA0) Preface. Properties 1. Diagnostics 2.
SIMATIC ET 200S distributed I/O SIMATIC Preface Properties 1 Diagnostics 2 ET 200S distributed I/O Digital electronic module 8DO DC24V/0.5 A (6ES7132-4BF00-0AA0) Manual 04/2007 A5E01077385-01 Safety Guidelines
More informationMain Catalog 2012/2013 for specialists in automation and control technology
Main Catalog 2012/2013 for specialists in automation and control technology www.vipa.com Welcome to VIPA This is VIPA Specialists in automation and control systems. Developer in some to the most advanced
More informationCompact multiprotocol I/O module for Ethernet 8 digital PNP inputs and 8 digital PNP outputs 2 A TBEN-L1-8DIP-8DOP
EtherNet/IP, Modbus TCP, or PROFINET slave Integrated Ethernet switch Supports 10 Mbps/100 Mbps 2 x M12, 4-pin, D-coded, Ethernet fieldbus connection 7/8" males, 5-pin, for power supply Separated power
More information6ES7 313-6BE01-0AB0 6ES7 313-5BE01-0AB0
4 SIMATIC S7-300 Central processing units CPU 312C to CPU 317F-2 DP CPU 317F-2 DP The failsafe CPU with a large program memory and quantity framework for demanding applications For configuration of a failsaf
More informationSIMATIC. ET 200S distributed I/O 2AO I ST analog electronic module (6ES7135-4GB01-0AB0) Preface. Properties 1. Parameters 2.
SIMATIC ET 200S distributed I/O SIMATIC ET 200S distributed I/O 2AO I ST analog electronic module (6ES7135-4GB01-0AB0) Manual Preface Properties 1 Parameters 2 Diagnostics 3 Analog value representation
More informationDigital Expansion Modules Specifications
S7200 Programmable Controller System anual Digital Expansion odules Specifications Table A11 Digital Expansion odules Order umbers Order umber Expansion odel Digital Inputs Digital Outputs Removable Connector
More informationSet for Profibus DPV1 in IP20 TI-BL20-DPV1-8
Type code Ident no. 1545007 Number of channels 8 Dimensions (W x L x H) 110.3 x 128.9 x 74.4 mm Cable max. 50 m between interface and read/write head 2 decimal rotary coding switches for the adjustment
More information4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no. 6814053.
PROFINET slave Integrated Ethernet switch 100 Mbps supported 2 x M12, 4-pin, D-coded, Ethernet fieldbus connection Glass-fiber reinforced housing Shock and vibration tested Potted module electronics Protection
More informationPCAN-B10011S Bus Converter High-speed CAN to Truck Trailer CAN. User Manual. Document version 2.1.0 (2013-11-15)
PCAN-B10011S Bus Converter High-speed CAN to Truck Trailer CAN User Manual Document version 2.1.0 (2013-11-15) Products taken into account Product Name Model Part number PCAN-B10011S IPEH-002041 CANopen
More informationTelephone- and leased line modem for industrial applications TD-36
Telephone- and leased line modem for industrial applications TD-36 Modem for industrial PSTN- and leased line applications The TD-36 is an analogue V.34 PSTN modem as well as an industrial 2-wire leased
More informationRack mounted telephone- and leased line modem for industrial applications
Rack mounted telephone- and leased line modem for industrial applications TR-6 Rack modem for industrial PSTNand /-wire leased line applications The TR-6 is an analogue V. 9 -rack PSTN modem as well as
More informationSIMATIC NET. CP 243-2 AS-Interface Master B C. Preface Contents. Technical Description and Installation Instructions Interface to the User Program
Preface Contents SIMATIC NET CP 243-2 AS-Interface Master Manual Technical Description and Installation Instructions Interface to the User Program 2 in the S7-200 CPU Access to the Data of the AS-i Slaves
More informationABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x.16.6.1, 2CDG 110 1xx R0011
, 2CDG 110 1xx R0011 SA/S 8.16.6.1 2CDC 071 006 S0010 The 16/20 A Switch actuators are modular installation devices in Pro M Design for installation in the distribution board. The devices are especially
More informationTM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector
Product datasheet Characteristics TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus
More informationSIMATIC S7-300, CPU 315-2DP CPU WITH MPI INTERFACE INTEGRATED 24 V DC POWER SUPPLY 128 KBYTE WORKING MEMORY 2
6ES7315-2AG10-0AB0 Page 1 Product data sheet 6ES7315-2AG10-0AB0 SIMATIC S7-300, CPU 315-2DP CPU WITH MPI INTERFACE INTEGRATED 24 V DC POWER SUPPLY 128 KBYTE WORKING MEMORY 2. INTERFACE DP-MASTER/SLAVE
More informationZC-24DO CANopen I/O Module: 24 Digital Outputs
Z-PC Line EN ZC-24DO CANopen I/O Module: 24 Digital Outputs Installation Manual Contents: - General Specifications - Technical Specifications - Installation Rules - Electrical connections - DIP-switches
More informationCombi switchbox with integrated 3/2 way pilot valve
H Combi switchbox with integrated 3/2 way pilot valve Construction The GEMÜ combi switchbox with integrated 3/2 way pilot valve for pneumatically operated quarter turn actuators has a micro-processor controlled
More informationGE Power Controls FIELDBUS APPENDIX PROFIBUS DP. Doc. No.: ASTAT Plus PB_Appendix-v0
GE Power Controls = FIELDBUS APPENDIX PROFIBUS DP = Doc. No.: ASTAT Plus PB_Appendix-v0 Fieldbus Appendix: PROFIBUS DP 1 Fieldbus Introduction...... 2 1.1 Introduction to Profibus-DP... 2 1.2 Network Overview...
More informationProgrammable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2
Type code Ident no. 1545065 Number of channels 2 Dimensions (W x L x H) 108 x 145 x 77.5 mm CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100 Mbps Male
More informationSpecifications for EM223 24 VDC 4 In/4 Out and EM223 24 VDC 4 In/4 Relay Out
SIMATIC S7-200 EM223 Digital Combination Modules EM223 2 VDC In/ Out and EM223 2 VDC In/ Relay Out Table 1 Specifications for EM223 2 VDC In/ Out and EM223 2 VDC In/ Relay Out EM223 2VDC In/Out 6ES7 2231BF200XA0
More information0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N
55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils
More informationProduct Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP
Product Information Gateway For Connecting EnDat Encoders to PROFIBUS-DP April 2012 PROFIBUS Gateway For Connecting EnDat Encoders Encoders with EnDat interface for connection via gateway All absolute
More informationModular I/O System Analog and Digital Interface Modules
OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part
More informationE-STOP relays, safety gate monitors
Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided
More informationSet for PROFINET IO in IP20 TI-BL20-EN-PN-4
Cable max. 50 m between interface and read/write head Connection of up to 4 read/write heads via BL ident extension cables Mixed operation of HF and UHF read/ write heads Connectors /S2500 Type code Ident
More informationElectronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only
More informationIBS IP KIS A. Data Sheet INTERBUS-S. Digital I/O Module
IBS IP KIS A Data Sheet Digital I/O Module Data Sheet Revision C Product Description The IBS KIS IP A module is a digital I/O module for the extended installation remote bus. Features - InterBuS-S protocol
More informationData sheet GIOD.1 Input/output module with CAN bus. ERP no.: 5204183. www.guentner.de. Data sheet GIOD.1 V_3.0
Data sheet GIOD.1 Input/output module with CAN bus ERP no.: 5204183 www.guentner.de Page 2 / 10 Contents 1 GIOD.1... 3 1.1 Functional description...3 1.2 Connections... 5 1.3 Electrical properties of...
More informationapplicomio Profibus-DP
BradCommunications Profibus-DP network interface cards allow deterministic I/O data acquisition for PC-based control applications. Features New! Support of Windows 32-bit and 64-bit (WoW64) Support of
More informationSIMATIC. ET 200S distributed I/O Digital electronic module 8DI DC24V (6ES7131-4BF00-0AA0) Preface. Properties 1. Diagnostics 2.
SIMATIC ET 200S distributed I/O SIMATIC Preface Properties 1 Diagnostics 2 ET 200S distributed I/O Digital electronic module 8DI DC24V (6ES7131-4BF00-0AA0) Manual 04/2007 A5E01077339-01 Safety Guidelines
More informationis then retained absolutely without interruption.
Page 1 of 11 DC UPS uninterruptible power supplies - DC UPS module 15 A Compact design, only 50 mm wide Absolutely interruption-free buffering of power failures through immediate electronic connection
More informationSafety automation solutions
Operating principle, characteristics Preventa safety s types XPS AV,, For and switch monitoring Operating principle Safety s XPS AV, and are used for monitoring circuits conforming to standards EN/ISO
More informationFiessler Programmable Safety Center. Flexible Hard- and Software concept. Available with a safe bus system or/and two counter inputs
E L E K T R O N I K Appliance Description Programmable safety center FPSC Fiessler Programmable Safety Center Flexible Hard- and Software concept Available with a safe bus system or/and two counter inputs
More informationhttp://support.automation.siemens.com/ww/view/en/4067870&td=1
6ES7316-2AG00-0AB0 SIMATIC S7-300, CPU 316 Technical / CAx data nmlkji Technical Data nmlkj CAx data As of 2010-01-24 Power supply Input voltage Rated value (DC) permissible range, lower limit (DC) permissible
More informationElectronic Pressure Switch EDS 300
Electronic Pressure Switch EDS 300 User manual Page 2 of 16 Content 1. Functions of the EDS 300...3 2. Mounting...3 3. Operating keys on the membrane keypad...4 4. Digital display...4 5. Output function...5
More informationHSP GmbH Zum Handwerkerhof 2 90530 Wendelstein Tel. 09129 / 2852-0 Fax: 09129 / 2852-11 Web: www.hsshsp.de EMAIL: HSP@hsshsp.de NTG-3000.
NTG-3000 Transducer Data Sheet Document Version 2.8 Page 1 of 10 Versions / Revisions: Document Creation Author Description version date 2.0 2012-07-25 P. Compensis First official version 2.1 2012-08-24
More informationHARTING econ 3000 Introduction and features
HARTING Introduction and features HARTING es, unmanaged, for installation in control cabinets General Description Features The Fast es of the product family HARTING are suitable for industrial applications
More informationProgrammable set for Ethernet Modbus/TCP in IP20 TI-BL20-PG-EN-8
CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100 Mbps LEDs for display of supply voltage, group and bus errors as well as status and diagnostics Connection
More informationSmart DeviceNet Remote I/O Terminals
Smart DeviceNet Remote I/O Terminals ather and Use Information for Effective Preventive Maintenance et more useful data for preventive maintenance when you build cost-effective parallel information systems
More informationCombi B Alarm box. Mounting instructions
Combi B Alarm box Mounting instructions EN Mounting instructions Alarm box Combi B VdS, G113064, G113065, G113066 Table of Contents 1 Description... 3 2 System overview... 3 3 Structure... 3 3.1 Power
More informationL5354 ControlNet Communications Interface
L5354 ControlNet Communications Interface Technical Manual HA470733 Issue 2 Copyright SSD Drives Inc 2005 All rights strictly reserved. No part of this document may be stored in a retrieval system, or
More informationProfibus DP Network with DeltaV/EMERSON Digital Automation System and Ponto Series Remote I/O
Application Note NAP101 Profibus DP Network with DeltaV/EMERSON Digital Automation System and Ponto Series Remote I/O Summary Description...1 1. Introduction...2 2. Installation...3 3. Configuration...3
More informationInstallation Manual (English) Adjustable Active DP Terminator T1-Pepper Active RS485 segment termination for non-compliant cable
Installation Manual (English) Adjustable Active DP Terminator T1-Pepper Active RS485 segment termination for non-compliant cable Designed for use with the COMbricks SALT repeater All baudrates Redundant
More informationLight scene push button 8gang comfort flush-mounted 751688xx
751688xx Documentation Product name: Light scene push button 8gang comfort Design: flush-mounting type (Up) ETS search path: Push button / Push button general / Light scene push button 8gang comfort Functional
More informationMicro Contactors. Micro Contactor Relays. Micro Contactors With Solder Pins. Coil voltages. Micro Reversing Contactor. Technical Data.
Micro Contactors Micro Contactor Relays 0 Micro Contactors Micro Contactors With Solder Pins Coil voltages Micro Reversing Contactor 3 Technical Data 4 Dimensions 8 9 Micro Contactor Relays 4pole C Operated
More informationNX safety stand-alone
NX-S@ NX safety stand-alone stand-alone into machine automation Expandable safety system up to 32 safety connections or 63 standard connections controller flexible system lets your freely mix safety I/O
More informationContactless Encoder RI360P0-QR24M0-INCRX2-H1181
Compact, rugged housing Many mounting possibilities Status displayed via LED Immune to electromagnetic interference 1024 pulses per revolution (default) 360, 512, 1000, 1024, 2048, 2500, 3600, 4096, parametr.
More informationModel: DC-A2IO Advanced HVAC Controller
Model: DC-A2IO Advanced HVAC Controller Job Name: Schedule Reference: Date: DC-A2IO Advanced HVAC Controller Package PAC-IF01 M-Net Adapter AL2-14MR-D α2 Simple Application Controller Accessories AL2-2DA
More informationBL compact multiprotocol station for Industrial Ethernet SSI interface BLCEN-1M12MT-1SSI
Compact fieldbus I/O module in IP69K EtherNet/IP, Modbus TCP, or PROFINET slave Integrated Ethernet switch 10 Mbps / 100 Mbps Two males M12, 4-pin, D-coded, for fieldbus connection 2 rotary switches for
More informationOrdering Information. Cylindrical Proximity Sensor E2E/E2E2
Cylindrical Sensor E2E/E2E2 A New Series of Easy-to-use and Tough E2E/E2E2 Models Long-size E2E2 Sensor Conforms to CENELEC Ideal for a variety of applications. With a metal connector that can be tightened
More informationFLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX 759 26-06-2007 759 M1 02 E MES FLOW CALCULATOR 759-02/1
BAMOPHOX 759 E - M FLOW CALCULATOR INSTRUCTION MANUAL MESURES 22, Rue de la Voie des Bans - Z.I. de la Gare - 95100 ARGENTEUIL Tél : (33) 01 30 25 83 20 - Web : www.bamo.fr Fax : (33) 01 34 10 16 05 -
More informationHardware Manual RM CANview Ethernet
Hardware Manual RM CANview Ethernet Table of Contents 1 Legal Regulations...3 2 About the Device...4 3 Disposal...4 4 Important Information for Using CANview Ethernet...5 4.1 How to Open the Protection
More informationElectronic Control Devices The European Product Catalogue 2007
FX14 Field Controller (1/4) FX14 Field Controller The FX14 is an equipment field controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating,
More informationPCAN-MicroMod Universal I/O Module with CAN Interface. User Manual. Document version 2.1.0 (2014-01-16)
PCAN-MicroMod Universal I/O Module with CAN Interface User Manual Document version 2.1.0 (2014-01-16) Products taken into account Product Name Part number Model PCAN-MicroMod IPEH-002080 with firmware
More informationHow To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)
transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control
More informationTechnical Information POWER PLANT CONTROLLER
Technical Information POWER PLANT CONTROLLER Content The Power Plant Controller offers intelligent and flexible solutions for the control of all PV power plants in the megawatt range. It is suitable for
More informationHow To Use A Power Supply On A Powerline 2.2 (Ai)
KNX/EIB Product documentation Issue: 05.08.2010 629x1220 Push button sensor 3 comfort 1-gang Push button sensor 3 comfort 2-gang (1+1) Push button sensor 3 comfort 3-gang Push button sensor 3 comfort 4-gang
More informationSIMATIC S7-1200. It s the Interplay that makes the difference. Siemens AG 2010. All Rights Reserved.
SIMATIC S7-1200 It s the Interplay that makes the difference SIMATIC S7-1200 Controller SIMATIC S7-1200 CPUs CPU 1211C 3 configurations per CPU Dimensions W x H x D (mm) CPU 1212C CPU 1214C DC/DC/DC, AC/DC/RLY,
More informationHF series Hall effect joysticks
Distinctive features and specifications 1, 2 & 3 axis configurations Dual sensors for redundancy CANbus J1939 and CANopen options Voltage regulator, 24V supply option USB 1.1 HID interface option ized
More informationTPM Product Type 107-D162-NNT 48-channel digital input and 16-channel digital output module with pluggable terminal
Product Type 107-D162-NNT 48-channel digital input and 16-channel digital output module with pluggable terminal Specifications Size: (L122 x W123 x H104 mm) Series Interface: Half duplex RS-485 with transformer
More informationSiemens AG 2011. 3/42 Analog modules 3/42 EM 231 3/42 EM 232 3/42 EM 235 3/47 EM 231 thermocouple module 3/49 EM 231 RTD module
Siemens AG 2011 /2 Introduction /4 Central processing units /4 CPU 221 /4 CPU 222 /4 CPU 224 /4 CPU 224 XP, CPU 224 XPsi /4 CPU 226 /24 SIPLUS central processing units /24 SIPLUS CPU 221 /25 SIPLUS CPU
More informationInwall 4 Input / 4 Output Module
Inwall 4 Input / 4 Output Module IO44C02KNX Product Handbook Product: Inwall 4 Input / 4 Output Module Order Code: IO44C02KNX 1/27 INDEX 1. General Introduction... 3 2. Technical data... 3 2.1 Wiring Diagram...
More informationPanel Meters and Controllers Modular Panel Meter Type EDM 35
Panel Meters and Controllers Modular Panel Meter Type EDM 35 Modular digital panel meter, 3 1/2-digit Indicating or controlling current, voltage, resistance, temperature, tacho or frequency. Easy programming
More informationDVPPF02-H2. PROFIBUS DP Slave Communication Module Application Manual
DVPPF02-H2 PROFIBUS DP Slave Communication Module Application Manual Warning Please read this instruction carefully before use and follow this instruction to operate the device in order to prevent damages
More informationSIMATIC. SM 335 High-Speed Analog Input/Output Module for the SIMATIC S7-300
SIMATIC SM 335 High-Speed Analog Input/Output Module for the SIMATIC S7-300 Manual Preface, Contents Characteristics and Technical Specifications of the SM 335 Connecting the Inputs and Outputs of the
More informationInductive sensor NI10-M18-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M18 x 1 Chrome-plated brass DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR) M12
More informationDeviceNet Communication Manual
DeviceNet Communication Manual Soft-Starter Series: SSW-07/SSW-08 Language: English Document: 10000046963 / 00 03/2008 Summary ABOUT THIS MANUAL... 5 ABBREVIATIONS AND DEFINITIONS... 5 NUMERICAL REPRESENTATION...
More informationSOLARCARE SERIES PRODUCT AND APPLICATION GUIDE
SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE for solar energy management LEATEC Delivering Solutions for Energy Management SOLAR ENERGY DATA CENTER BUILDING 4 to8 String Monitoring with 0.% Accuracy
More informationDeviceNet Bus Software Help for Programming an Allen Bradley Control System
FBP FieldBusPlug V7 DeviceNet Bus Software Help for Programming an Allen Bradley Control System DeviceNet Software Help for Programming an Allen Bradley Control System Contents Page General Purpose...
More information5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual
5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual Content Overview... 1 Introduction... 1 Features... 3 Packing List... 4 Safety Precaution... 4 Hardware Description... 5 Front Panel...
More information48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0.
48 Series - Relay interface modules 8 A Features 48.12 2 Pole Safety relay interface modules, 15.8 mm wide 48.12-2 Pole 8 A (screw terminal) DC sensitive coils Relay with forcibly guided contacts according
More informationDMX2PWM 9 Channel Dimmer Setup Manual
DMX2PWM 9 Channel Dimmer Setup Manual www.ecue.de DMX2PWM 9ch Dimmer - Setup Manual e:cue control GmbH An OSRAM Company Rev. 1.3_01/2010 DMX2PWM 9ch Dimmer - Setup Manual Table of Contents 1. Device Overview....................................4
More informationVibration analysis and monitoring Compact. Powerful. Modern technology.
Vibration analysis and monitoring Compact. Powerful. Modern technology. Maximum performance Vibration measurement with state of the art processor technology Expert Vibro is Delphin Technology's new device
More informationTechnical data. General specifications. Signal voltage 15... 30 V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.
Model Number Features Very small housing High climatic resistance 4 Bit multiturn Analog output Surge and reverse polarity protection Description This absolute rotary encoder with internal magnetic sampling
More informationABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01
ABB Drives User s Manual Pulse Encoder Interface Module RTAC-0 Pulse Encoder Interface Module RTAC-0 User s Manual 3AFE 64486853 REV A EN EFFECTIVE:.5.00 00 ABB Oy. All Rights Reserved. Safety instructions
More information38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays
More informationT200, PTP/IEEE 1588 Grandmaster Clock and
T200, PTP/IEEE 1588 Grandmaster Clock and NTP Time Server with high accuracy GPS receiver, OCXO or Rubidium oscillator 1 Bd d Armor 22300 LANNION - FRANCE contact@heoldesign.com 1 HEOL-T200 : PERFORMANCE
More informationDAM Series DAM124 4DIN+8AI+4DO Module Model No.:DAM124 WebSite: www.gsm-m2m.com
DAM Series DAM124 4DIN+8AI+4DO Module Model No.:DAM124 WebSite: www.gsm-m2m.com This handbook has been designed as a guide to the installation and operation of King Pigeon Hi-Tech.Co.,Ltd DAM series. Statements
More informationUSER MANUAL V5.0 ST100
GPS Vehicle Tracker USER MANUAL V5.0 ST100 Updated on 15 September 2009-1 - Contents 1 Product Overview 3 2 For Your Safety 3 3 ST100 Parameters 3 4 Getting Started 4 4.1 Hardware and Accessories 4 4.2
More informationColor Mark Sensor with Red or Green LED E3S-VS
Color Mark Sensor with Red or Green LED Rugged IP67 Color Mark Sensor 1 ms response time Detects a wide variety of color marks PNP or NPN output ls Light-on/ Dark-on operation, wire selectable Vertical
More informationMDM192 MULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE. USER GUIDE Document reference : 9010709-03
MDM192 MULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE USER GUIDE Document reference : 9010709-03 If you have questions about the MDM192 or desire assistance, contact ETIC TELECOMMUNICATIONS at the following
More informationSafety technique. Emergency stop module BO 5988 safemaster
Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1
More informationNEW. EVEN MORE data acquisition and test stand automation
NEW EVEN MORE data acquisition and test stand automation the new class of data The plug&play complete package User benefits Expert Series is the latest generation of data acquisition Complete hardware
More informationDigital input modules
8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a
More informationPCS0100en 02.2008. Persy Control Services B.V. Netherlands
P-Bus Gateway PBGW2.128 Universal gateway between the P-bus protocol and open standard protocols. The variety of available electrical interfaces on the gateway offers a wide range of possibilities for
More informationPositive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous
Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of
More informationOption field bus: without bus with profibus DP. Design-Index (Subject to change)
Amplifier / controller cards ED1 Digital amplifier / controller card ED1 for 1 or 2 proportional solenoids 4 analogue inputs, of which 2 for differential inputs 8 digital inputs Card setting via PC, multi-function
More informationSENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications
Fiber Optic Sensors - S7 Advanced fiber optic amplifiers for high speed and low contrast applications DIN rail mountable models with dual digital displays speed models: 2 μs...5 ms Super high speed models:
More informationHow To Use A Light Bulb With A Power Supply (Power Supply)
DeviceNet Fieldbus Solutions Fieldbus Communication for DeviceNet Applications Lumberg Automation Provides Reliable DeviceNet Fieldbus Solutions for Industrial Automation Applications Worldwide. DeviceNet
More informationCopyrights 2010 Victron Energy B.V. All Rights Reserved
Manual EN 1 Copyrights 2010 Victron Energy B.V. All Rights Reserved This publication or parts thereof may not be reproduced in any form, by any method, for any purpose. For conditions of use and permission
More informationDCS Input/Output Relay Card Series
Input/Output Relay Card Series I/O RELAY CARD (with loopback test function) 8N The 8N series I/O Relay Cards easily and quickly standardize and facilitate installation of the relay board. Loopback test
More informationSwitch Actuator, 8-fold, 10 A, MDRC AT/S 8.10.1, GH Q631 0075 R0111
, GH Q631 0075 R0111 The 8-fold switch actuator is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via a bus terminal. In the event of bus voltage failure,
More informationRISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER
Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.
More informationTHYRISTORS T1-1PH from 850A to 2700A Specifications Universal 1 Phase Thyristor Unit 55-77-03-62, March 2012
Technical Information THYRISTORS T1-1PH from 850A to 2700A Specifications Universal 1 Phase Thyristor Unit 55-77-03-62, March 2012 GENERAL DESCRIPTION THYRISTORS T1-1PH is a full digital and universal
More informationComputer Controlled Generating Stations Control and Regulation Simulator, with SCADA SCE
Technical Teaching Equipment Computer Controlled Generating Stations Control and Regulation Simulator, with SCADA SCE EDIBON SCADA System Teaching Technique used 4 5 2 Data Acquisition Board Cables and
More informationJNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
More information