Telephone- and leased line modem for industrial applications TD-36
|
|
- Herbert Manning
- 7 years ago
- Views:
Transcription
1 Telephone- and leased line modem for industrial applications TD-36 Modem for industrial PSTN- and leased line applications The TD-36 is an analogue V.34 PSTN modem as well as an industrial 2-wire leased line modem. V.34 provides data rates up to 33.6kbit/s on the communication line. Several features make it ideal for use in industrial applications: Password protection, dial-back security and caller ID answering are only some of its features. The RS-232 interface is accessable via either 9 pin D-sub or screw terminals. A Windows modem driver is supplied with the unit for PC based applications. The TD-36 is the ideal choice for industrial dial-up and 2-wire leased line applications. Configuration and diagnostics The TD-36 is configurable via its serial interface in several ways, either via standard terminal emulation software using AT-Hayes commands or Westermo s own modem configuration, TD-Tool. Additionally the TD-36 can be configured via its onboard DIP-switches. TD-Tool is a Windows based configuration GUI that simplifies setting up the modems, connection statistics can be viewed and configurations saved for further use. To assit in fault finding and reconfiguration of unmanned stations, the modem can be configured remotely via a PSTN connection. Harsh industrial environment TD-36 is designed to function reliably within industrial environments and in areas of high-level interference. The modem is equipped with transient protection on the line side and a watchdog that monitors and automatically resets the modem in the event of a fault. The TD-36 is designed to be mounted easily on to a 35 mm DIN-rail, it has screw terminal connections, an extended temperature range from -25 C to +70 C and is tri galvanically isolated. The power supply operates over a wide input range, and can be delivered with different power supply options. Approvals The construction of the units has gone through extensive testing and approvals both by Westermo and approved test houses. The TD-36 is approved for use in Europe, as well as in USA and Canada. Industrial PSTN Modems
2 Application Telephone network Leased Line Interfaces DIP-switches Accessible under lid LED indicators Line connection Up to 33.6 kbit/s RS-232 Up to kbit/s Line connection 2-wire leased line Up to 33.6 kbit/s Power interface Applications, interfaces
3 Technical Data Power AV Rated voltage Operating voltage Rated current 20 to 250 VDC 24 to 240 VAC 18 to 300 VDC 22 to 264 VAC VDC VDC VDC VAC VAC VAC Rated frequency DC: AC: Hz Inrush current I 2 t 0.45 A 2 s Startup current* 0.25 Apeak Polarity Polarity independent Isolation to All other ports 3 kvrms 50 Hz 1 min Connector size mm 2 (AWG 24-12) Power LV Rated voltage Operating voltage Rated current 12 to 48 VDC 12 to 27 VAC 10 to 60 VDC 10 to 30 VAC Hz VDC VDC VDC VAC VAC Rated frequency DC: AC: Hz Inrush current I 2 t 0.25 A 2 s Startup current* 0.30 Apeak Polarity Polarity independent Isolation to All other ports 3 kvrms 50 Hz 1 min Connector size mm 2 (AWG 24-12) * External supply current capability for proper startup
4 Public Switched Telephone Network (PSTN) Electrical specification Public Switched Telephone Network 300 bit/s 33.6 kbit/s B103, B212, V21, V22, V22B, V23C, V23 HDX, V32, V32B, V34 Protection Installation Fault Tolerant (up to ±60 V) RS kvrms 50 Hz 1 min RJ-11C and Connector size mm 2 (AWG 24 12) Leased Line (LL) Electrical specification 2- or 4-wire Leased Line 300 bit/s 33.6 kbit/s B103, B212, V21, V22, V22B, V23C, V23 HDX, V32, V32B, V34 Transmission range PSTN 30 db Budget Leased Line max 40 db Protection Installation Fault Tolerant (up to ± 60 V) RS kvrms 50 Hz 1 min Connector size mm 2 (AWG 24 12) RS-232 Electrical specification EIA/TIA bit/s kbit/s Data format 7 or 8 data bits, Odd, even or none parity, 1 or 2 stop bits, 9-12 bit words Transparent Retiming Yes Transmission range Cable length 15 m PSTN Line 2 kvrms 50 Hz 1 min 9-pin D-sub female (DCE) and (DCE ) Connector size mm 2 (AWG 24 12) * * Railway installation close to the rails. For a cable located within 3 m and connected to this port, the use of shielded cable is recommended, this is to minimise the risk of interference. The cable shield should be properly connected (360 ) to an earthing point within 1 m of this port. This earthing point should have a low impedance connection to the conductive enclosure of the apparatus cabinet, or similar, where the unit is builtin. This conductive enclosure should be connected to the earthing system of an installation and may be directly connected to the protective earth.
5 Type tests and environmental conditions Electromagnetic Compatibility Phenomena Test Description Test levels ESD EN Enclosure contact ± 6 kv Enclosure air ± 8 kv RF field AM modulated IEC Enclosure 10 V/m 80% AM (1 khz), MHz 20 V/m 80% AM (1 khz), MHz RF field 900 MHz ENV Enclosure 20 V/m pulse modulated 200 Hz, 900 ± 5 MHz Fast transient EN Signal ports ± 2 kv ± 2 kv Surge EN Signal ports unbalanced ± 2 kv line to earth, ± 2 kv line to line Signal ports balanced ± 2 kv line to earth, ± 1 kv line to line ± 2 kv line to earth, ± 2 kv line to line RF conducted EN Signal ports 10 V 80% AM (1 khz), MHz 10 V 80% AM (1 khz), MHz Voltage dips and interruption EN AC power ports 10 & ms, interruption 10 & 500 ms, 30% reduction 100 & ms, 60% reduction Mains freq. 50 Hz EN Signal ports 100 V 50 Hz line to earth Voltage dips and interruption EN DC power ports 10 & 100 ms, interruption 10 ms, 30% reduction 10 ms, 60% reduction +20% above & 20% below rated voltage Radiated emission EN Enclosure Class A FCC part 15 Class A Conducted emission EN AC power ports Class B FCC part 15 AC power ports Class B EN DC power ports Class B Dielectric strength EN Signal port to other isolated ports 2 kvrms 50 Hz 1 min Power port to other isolated ports 3 kvrms 50 Hz 1 min 2 kvrms 50 Hz 1 min rated power <60 V) Environmental Temperature Operating 25 to +70 C Storage & Transport 40 to +70 C Humidity Operating 5 to 95% relative humidity non condensing Storage & Transport 5 to 95% relative humidity non condensing Altitude Operating m / 70 kpa Reliability prediction (MTBF) MIL-HDBK- 217F Operating Service life Operating 10 year Vibration IEC Operating 7.5 mm, 5 8 Hz 2 g, Hz Shock IEC Operating 15 g, 11 ms Packaging Enclosure UL 94 PC / ABS Flammability class V-1 Dimension W x H x D 55 x 100 x 132 mm Weight 0.36 kg Degree of protection IEC 529 Enclosure IP 20 Cooling Convection Mounting Horizontal on 35 mm DIN-rail
Rack mounted telephone- and leased line modem for industrial applications
Rack mounted telephone- and leased line modem for industrial applications TR-6 Rack modem for industrial PSTNand /-wire leased line applications The TR-6 is an analogue V. 9 -rack PSTN modem as well as
MODEM RS232 <=> RTC<=> RS485 Operating instructions
MODEM Operating instructions GB MAKE YOUR BUSINESS SAFE SOCOMEC GROUP SWITCHING PROTECTI & UPS GB Contents GENERAL INFORMATI 3 Safety 3 Maintenance 3 INTRODUCTI 4 Description 4 Characteristics 4 APPROVALS
User Guide. Westermo Teleindustri AB 6600-2204 TD-23. Leased Line V.23 Modem Multidrop applications. www.westermo.com
User Guide 6600-2204 TD-23 Westermo Teleindustri AB Leased Line V.23 Modem Multidrop applications www.westermo.com Legal information The contents of this document are provided as is. Except as required
TD-36 TD-36. DIN-rail Tele and Leased Line modem TD-36 485 DIN-rail Tele and Leased Line modem with I/O and RS-485. User Guide 6618-2202
User Guide 6618-2202 TD-36 Westermo Teleindustri AB TD-36 DIN-rail Tele and Leased Line modem TD-36 485 DIN-rail Tele and Leased Line modem with I/O and RS-485 www.westermo.com Legal information The contents
User Guide. Westermo Teleindustri AB 6614-2202 TR-36. Tele and leased line modem for RV-07 19 rack system. www.westermo.com
User Guide 6614-2202 TR-36 Westermo Teleindustri AB 4 3 2 1 4 3 2 1 Tele and leased line modem for RV-07 19 rack system www.westermo.com Legal information The contents of this document are provided as
TD-36 TD-36. DIN-rail Tele and Leased Line modem TD-36 485 DIN-rail Tele and Leased Line modem with I/O and RS-485. User Guide 6618-2201
User Guide TD-36 6618-2201 Westermo Teleindustri AB 2006 TD-36 DIN-rail Tele and Leased Line modem TD-36 485 DIN-rail Tele and Leased Line modem with I/O and RS-485 www.westermo.com Legal information The
Waveguide Access Point WGA631. Product Guide
Waveguide Access Point Product Guide Waveguide Access Point Contents 1. Description............................ 3 2. Application............................ 3 3. Technical data... 4 4. Physical interfaces......................
Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ
Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage without power de-rating Efficiency > 87.0% @ 115Vac & 230Vac NEC Class 2 / Limited
Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ
Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage without power de-rating Efficiency > 87.0% @ 115Vac, > 89.0% @ 230Vac NEC Class
Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG
Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage and full power up to 55 C Power will not de-rate for the entire input voltage range
TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector
Product datasheet Characteristics TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus
Quick Connect. quick - simple - efficient. www.g-mw.de
Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power
RoHS APPROVAL SHEET. ituner 12V/6.6A SERIES NO. (E17) EA10953A. ( ) Edac Power Electronics (Suzhou) Co., Ltd. 59 No.59, Chang Sheng Road, Sheng Pu,
APPROVAL SHEET CUSTOMER ituner CUSTOMER P/N DESCRIPTION EDAC MODEL 12V/6.6A SERIES NO. (E17) EA10953A DATE 2010-06-22 REVISION 0 APPROVED DESIGN PREPARE RoHS CONCLUSION APPROVED CONDITON CUSTOMER S APP
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays
Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only
Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1
Power Supply Unit, Primary Switched, Narrow Design MINI POWER provides: Extra narrow design with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide-range input
STRATO LED Drivers 70W, Single output
Features STRATO switch mode driver technology is designed to generate one constant current output from a wide range AC input. The size and performance of these products make them the ideal choice for LED
CliQ DIN Rail Power Supply 24V 120W 1 Phase / DRP024V120W1AA
Highlights & Features Reliable design, with expected life of 10 years Compact, rugged design for ease of handling and installation Multiple connections to terminals allowed Designed for Class I Div. 2
Redundancy Module QUINT-DIODE/40
Redundancy Module QUT DIODE provides: 00% decoupling of power supplies connected in parallel Can be installed in potentially explosive areas Load currents up to 60 A supported Easy assembly by snapping
MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features
Central 48 V DC Power Supplies for PoE-Components MICROSENS Description Active network equipment which is supporting the Power-over-Ethernet functions, typically requires a powerful 48 V DC power supply.
ZC-24DO CANopen I/O Module: 24 Digital Outputs
Z-PC Line EN ZC-24DO CANopen I/O Module: 24 Digital Outputs Installation Manual Contents: - General Specifications - Technical Specifications - Installation Rules - Electrical connections - DIP-switches
Vert-X 16-5V / 10...90% Ub. Applications Servodrives Dancer arm Operating table
Version MH-C MH-C2 Electrical data Measuring range 0... 360 - Indep. linearity % meas. range ±0.3 - Max. hysteresis 0.1 - Resolution bit 12 - Max. repeatability 0.1 - Sample rate fast mode khz (5) - Sample
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical
Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter
FEATURES: Click on Series name for product info on aimtec.com Models Single output Model Max Output Power (W) 1 AC-DC Constant Current or Constant Over temperature protection Voltage LED Driver Over current
O WA-120U series IP67. 120W Single Output Switching Power Supply. Features. Aplications
Features UniversalACinput/Fulrange Built-inactivePFCfunction Higheficiencyupto91% Protections:Shortcircuit/Overcurent/ Overvoltage/Overtemperature Fanlesdesign,colingbyfreairconvection Colingbyfreairconvection
XPress-Pro SW Series Hardened Ethernet Switches Enabling Communication for the Demanding Industrial Environment
XPress-Pro SW Series Hardened Ethernet Switches Enabling Communication for the Demanding Industrial Environment Part of the device networking family of networkenablement products, XPress-Pro SW series
7.5 Watt AC-DC Switch Power Supply
MAIN FEATURES: 7.5W Small Compact Size PCB Mount Single Output Regulated Output Range : 3.3VDC 24VDC Input Range : 85VAC 265VAC/47 63Hz Or 120VDC 370VDC Very Low Standby Power Consumption < 0.15W Better
Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description
Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display
EPL225 Series. 225 Watts. www.xppower.com. AC-DC Power Supplies. Models & Ratings. Summary
225 Watts 50 W Convection/ 225 W Forced-cooled Ratings 2 by 4 Footprint Low.26 Profile 2 V Fan Output High Efficiency, up to 95% ITE & Medical pprovals High Power Density Less than 0.5 W No Load Input
5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual
5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual Content Overview... 1 Introduction... 1 Features... 3 Packing List... 4 Safety Precaution... 4 Hardware Description... 5 Front Panel...
PCS0100en 02.2008. Persy Control Services B.V. Netherlands
P-Bus Gateway PBGW2.128 Universal gateway between the P-bus protocol and open standard protocols. The variety of available electrical interfaces on the gateway offers a wide range of possibilities for
Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D
7000/7000C/7020 Multi-instrument 4921210109D Features Measurements All 3-phase AC measurements True RMS Replaces analogue meters Demand on each phase current Accuracy U, I and F class 0.5 Other values
Application. Characteristics RTU560. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11
Communication Unit 560CMD11 The SLC works as master for the RTU560 serial peripheral bus (I/O-Interface/ Wired-OR-Bus ). The MPU is responsible for the other tasks. The MPU handles the absolute time and
RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER
Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.
Energy Management Energy Meter Type EM23 DIN
Energy Management Energy Meter Type EM23 DIN Class 1 (kwh) according to EN62053-21 Class B (kwh) according to EN50470-3 Class 2 (kvarh) according to EN62053-23 Accuracy ±0.5 RDG (current/voltage) Energy
Electronic Control Devices The European Product Catalogue 2007
FX07 Field Controller (1/4) FX07 Field Controller Display Model Dimensions in mm (inches) The FX07 is a terminal unit controller in the Facility Explorer range of products. The controller is designed specifically
IntesisBox Modbus Server Fidelio IP
IntesisBox Server Fidelio IP Gateway for integration of Micros Fidelio Ho management system into (RTU and TCP) enabled control systems. Integrate your Micros Fidelio Ho management system into your master
650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power
Features: Universal AC input / Full range Programmable output Voltage (0% ~ 05%) Programmable output Current (% ~ 05%) + / 0.5A auxiliary output Forced current sharing at parallel operation Power OK signal
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection
IntesisBox KNX LG Air Conditioning
IntesisBox KNX LG Air Conditioning Gateway for integration of LG Air Conditioners with KNX control systems. 1. Main Features Direct connection to KNX TP-1 (EIB) bus. Direct connection to LG outdoor unit
is then retained absolutely without interruption.
Page 1 of 11 DC UPS uninterruptible power supplies - DC UPS module 15 A Compact design, only 50 mm wide Absolutely interruption-free buffering of power failures through immediate electronic connection
Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800
Power-monitoring unit PowerLogic System Technical data sheet 2003 Power Meter Series 800 Function and characteristics PB100313 The PowerLogic Power Meter Series 800 offers all the high-performance measurement
Single-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable
Features 70.11 70.31 70.41 Electronic voltage monitoring relays for single and three-phase applications Multifunctional types, providing the flexibility of monitoring Undervoltage, Overvoltage, Window
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection
CliQ DIN Rail Power Supply 24V 120W 1 Phase / DRP024V120W1AA
Highlights & Features Universal AC input voltage Power will not de-rate for the entire input voltage range Power Boost of 150% for 3 seconds Full corrosion resistant aluminium chassis SEMI F47 certified
Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit
Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit SLCLE5504AUX for Use with Wired C-Bus Networks Instruction Bulletin Retain for future use. Square D Clipsal DIN-Rail Four-Channel Auxiliary Input
80 Series - Modular timers 16 A. Features 80.01 80.11
80 Series - Modular timers 16 A Features 80.11 Multi-function and mono-function timer range - Multi-function & multi-voltage 80.11 - On-delay, multi-voltage 17.5 mm wide Six time scales from 0.1s to 24h
Operating Manual UWAPS-TINY Series
Operating Manual UWAPS-TINY Series Powecon Oy WWW.POWECON.FI 1/9 Table of content 1 Warranty...3 2 Safety information...3 3 Abbreviations and terminology...3 4 List of appendices...4 5 Introduction...4
TEST REPORT EN 55014-2 (1997) +A1 (2001)
Page 1 of 23 TEST REPORT EN 55014-2 (1997) +A1 (2001) Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus Part 2: Immunity Report Reference No....
Rated Power(W) 8W 2. EG-LED0840-01 8W 3. EG-LED1027-01 10W
14713221 001 Seite 2 von 37 Page 2 of 37 Model List: No Model Rated Voltage(V) 1. EG-LED0827-01 Rated Power(W) 8W 2. EG-LED0840-01 8W 3. EG-LED1027-01 10W 4. EG-LED1040-01 AC 100-240V, 10W 5. EG-LED1027-02
Single Output Switching Power Supply
.. RS- Code: CLP-A Single Output Switching Power Supply SPECIFICATION MODEL OUTPUT INPUT PROTECTION ENVIRONMENT SAFETY EMC (Note 6) OTHERS NOTE DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER RIPPLE
www.murata-ps.com D1U54P-W-1200-12-HxxC Series 54mm 1U Front End AC-DC Power Supply Converter www.murata-ps.com/support PRODUCT OVERVIEW FEATURES
www.murata-ps.com PRODUCT OVERVIEW D1U54P-W-1200-12-HxxC Series The D1U54P-W-1200-12-HxxC series are 80 PLUS Platinum effi ciency 1200 watt, power factor corrected front end supplies with a 12V main output
JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
Application/Connection Examples
This Quick Start Guide is designed to familiarize the user with the connection and configuration of the DTS-305 DIN rail mounted single / 3 phase power & energy meter with RS-485 or TCP communications.
Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2
Type code Ident no. 1545065 Number of channels 2 Dimensions (W x L x H) 108 x 145 x 77.5 mm CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100 Mbps Male
LevelOne IFE-0500 4-Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual
LevelOne IFE-0500 4-Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual Ver. 1.0.0-0711 1 FCC Warning This Equipment has been tested and found to comply with the limits for a Class-A digital
Power Supplies 3. SDN-P DIN Rail Series
SDN-P DIN Rail Series The SDN DIN Rail power supplies provide industry leading performance. Sag Immunity, transient suppression and noise tolerant, the SDN series ensures compatibility in demanding applications.
Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)
Data sheet Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) The temperature monitoring relays CM-TCS monitor overtemperature,
STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase
Extract from the online catalog STEP-PS/1AC/12DC/1.5 Order No.: 2868567 DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Commercial data EAN 4046356292924 Pack 1 pcs. Customs tariff
MasterINTERFACE 39 Series - Relay interface modules
MasterINTERFACE 39 Series - Relay interface modules Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy
CPCI-3U-AC-300W-R. Rugged 300W AC Input 3U CompactPCI Power Supply. Electrical Specification for: Telkoor Part Number: 900-4602-0000
Electrical Specification for: CPCI-3U-AC-300W-R Rugged 300W AC Input 3U CompactPCI Power Supply Telkoor Part Number: 900-4602-0000 GENERAL SCALE RELEASE DATE 12/9/06 SHEET 1 OF 6 REVISION HISTORY Rev Level
PSI-DATA/FAX-MODEM/RS232
Industrial analog modem INTERFACE Data sheet 100500_en_01 PHOENIX CONTACT - 10/2008 1 Description The DIN rail-mountable PSI-DATA/FAX-MODEM/RS232 is specifically designed to meet industrial requirements
Electronic Control Devices The European Product Catalogue 2007
FX14 Field Controller (1/4) FX14 Field Controller The FX14 is an equipment field controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating,
RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:
Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog
Power Supply, Primary Switch Mode, Narrow Design MINI-PS-100-240AC/24DC/2
Power Supply, Primary Switch Mode, Narrow Design -PS-100-240AC/24/2 POWER provides: Extra narrow widths of 22.5 and 45 mm (0.886 and 1.772 in.) Global use due to a wide range input A high level of operational
1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)
000W Single Output Power Supply AK-000 series Features: Universal AC input / Full range Programmable output Voltage (0% ~ 05%) Programmable output Current (% ~ 05%) + / 0.5A auxiliary output U profile,
38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.
38 Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit 6.2 mm wide EMR - DC, AC or AC/DC
R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0
FieldBarrier Features Assembly 8... 12 outputs Ex ia IIC, FISCO and Entity Advanced fault isolation and diagnostics at the spur FieldBarrier in Zone 1/Div. 2 Instruments in Zone 0...1/Div. 1 For FOUNDATION
Power Supply, Primary Switch Mode, Narrow Design MINI-PS-100-240AC/2x15DC/1
Power Supply, Primary Switch Mode, Narrow Design -PS-100-240AC/2x15DC/1 POWER provides: Extra narrow widths of 22.5 and 45 mm (0.886 and 1.772 in.) Global use due to a wide range input A high level of
I STAR COMPUTER CO., LTD
I STAR COMPUTER CO., LTD Mini Redundant Power Supply 300W+300W for IPC-Computer Model No. TC-300R8 Table of content 1. Introduction...1 2. Specification 2.1 Input Voltage...1 2.2 DC Output...1 2.3 PS-ON
Antec TruePower User's Manual
User s Manual Antec TruePower User's Manual Antec TruePower ATX12V power supply Models: TRUE330, TRUE380, TRUE430, TRUE480, TRUE550 Antec Low Noise Technology: The Antec TruePower power supply is equipped
1756 ControlLogix Chassis Specifications
Technical Data 1756 ControlLogix Chassis Specifications Catalog Numbers 1756-A4/B, 1756-A4K/B, 1756-A4/C, 1756-A4K/C, 1756-A7/B, 1756-A7K/B, 1756-A7/C, 1756-A7K/C, 1756-A10/B, 1756-A10K/B, 1756-A10/C,
NFF Series. CoolX600 NFF Series Cool. Patented Resonant Technology. NFF Series; No Fan Featured
Cool TM 600 NFF Series Patented Resonant Technology NFF Series; No Fan Featured 100% natural convection cooled No internal or external fans needed No base-plate needed No Acoustic Noise or Vibrations &
Thermistor motor protection relays CM-MSS.22 and CM-MSS.23
Data sheet Thermistor motor protection relays CM-MSS.22 and CM-MSS.23 The thermistor motor protection relays CM-MSS.22 and CM-MSS.23 monitor the winding temperature of motors and protect them from overheating,
How To Run An Nport I5000A Device Server
NPort IA5000A Series 1, 2, and 4-port serial device servers for industrial automation Enhanced surge protection for serial, LAN, and power 2 KV isolation for serial signals Rugged screw-type terminal blocks
PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description
Photoelectrics, Background Suppression reflective with IR light Main features Description The PD30ET... stainless steel sensors are built with high-quality materials and designed for harsh environments.
FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology
FOSTCDR pn 8684R1 FOSTCDR-0812ds page 1/5 Industrial Serial to Multimode Fiber Optic Converter Data Rates up to 115.2 kbps 2.5 Mile (4 km) Range 10 to 30 VDC Input Voltage Wide Operating Temperature 2000V
Power Meter Series 700
PowerLogic power-monitoring units Power Meter Series 700 Technical data sheet 2007 Functions and characteristics E90463 The PowerLogic Power Meter Series 700 offers all the measurement capabilities required
ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories
2CDC 251 014 F0t09 Features Monitoring of three-phase mains for grid feeding Type-tested in accordance with DIN V VDE V 0126-1-1: February 2006 Neutral conductor connection configurable Can also be used
Unidirectional Transmitter/ Receiver Units Introduction
Unidirectional Transmitter/ Receiver Units Introduction Wireless Input/Output (I/O) connects directly to analog, discrete and pulse transducer signals. The signals are transmitted by radio and either re-created
HSP GmbH Zum Handwerkerhof 2 90530 Wendelstein Tel. 09129 / 2852-0 Fax: 09129 / 2852-11 Web: www.hsshsp.de EMAIL: HSP@hsshsp.de NTG-3000.
NTG-3000 Transducer Data Sheet Document Version 2.8 Page 1 of 10 Versions / Revisions: Document Creation Author Description version date 2.0 2012-07-25 P. Compensis First official version 2.1 2012-08-24
Foxboro Evo Process Automation System
Foxboro Evo Process Automation System Product Specifications PSS 31H-2Z32 FBM232 Field Device System Integrator Module, 10/100 Mbps Ethernet, Single The FBM232 Field Device System Integrator (FDSI) module
Programmable set for Ethernet Modbus/TCP in IP20 TI-BL20-PG-EN-8
CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100 Mbps LEDs for display of supply voltage, group and bus errors as well as status and diagnostics Connection
TEP 200WIR Series, 180 240 Watt
TEP 200WIR Series, 180 240 Watt Features Chassis mount with screw terminal block Including EMI filter to meet EN 55022, class A Ultra wide 4:1 input voltage ranges 8.5 36, 16.5 75, 43 160 VDC EN 50155
MDM192 MULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE. USER GUIDE Document reference : 9010709-03
MDM192 MULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE USER GUIDE Document reference : 9010709-03 If you have questions about the MDM192 or desire assistance, contact ETIC TELECOMMUNICATIONS at the following
Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet
Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order
MCR1900 Media Converter 19-Slot Chassis
MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the
DVPPF02-H2. PROFIBUS DP Slave Communication Module Application Manual
DVPPF02-H2 PROFIBUS DP Slave Communication Module Application Manual Warning Please read this instruction carefully before use and follow this instruction to operate the device in order to prevent damages
Relés e Contatores de Estado Sólido SIRIUS
Relés e Contatores de Estado Sólido SIRIUS Coletânea de dados técnicos ( product data sheet ) Agosto/212 SSR - 3RF21 22,5 mm Ponto Zero SSR - 3RF2 45 mm Ponto Zero SSR - 3RF22 45 mm Ponto Zero Trifásico
Moxa EtherDevice Switch
Moxa EtherDevice Switch EDS-205 Hardware Installation Guide Third Edition, June 2008 2008 Moxa Inc., all rights reserved. Reproduction without permission is prohibited. P/N: 1802002050000 Overview The
IntesisBox KNX Modbus RTU master
IntesisBox KNX RTU master Gateway for integration of RTU devices into KNX control systems. Integrate RTU devices (Chillers, Roof Tops, electricity meters, heating floors, heat pumps, PLCs ) into KNX control
SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:
SWITCH The Budderfly lighting switch is a Decora style, plug-and-play replacement for your existing building switches. Installing a Budderfly adapter transforms your building s existing wiring into the
2-Port RS232/422/485 Combo Serial to USB2.0 Adapter (w/ Metal Case and Screw Lock Mechanism) Installation Guide
2-Port RS232/422/485 Combo Serial to USB2.0 Adapter (w/ Metal Case and Screw Lock Mechanism) Installation Guide 1. Introduction Thank you for purchasing this 2-Port RS232/422/485 Combo Serial to USB Adapter.
Fieldbus slave modules with I/Os, DIO
140 Fieldbus slave modules with I/Os, DIO 1534CF00 1534CH00 1534PF00 1534PH00 1536CH00 1536CL10 1536PH00 1536PL00 Order number 1534CF00 1534CH00 1534PF00 1534PH00 Figure Type SM 153, CANopen slave, DIO
Three-phase monitoring relay CM-PFE
Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics
Repeaters and Mimics Data Sheet
Repeaters and Mimics Data Sheet IDR series repeaters and mimics allow vital information from a Notifier fire system to be communicated to points around a building remote from the fire alarm control panel.
ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.
IntesisBox ModBus Server - KNX Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems. Integrate KNX based lighting control into your SCADA, BMS, PLC "talking" Modbus. Master
Application. Key Features. Benefits. Contact us. Solution for GSM-R coverage. AIR Repeater RF/RF GSM-R 900. To ensure GSM-R coverage everywhere
Application GSM-R 900 coverage enhancement Outdoor : Cell extension Indoor : Tunnels and confined areas Key Features Medium & High Power Band- & Channel- Selective Digital Smart Filter Outdoor IP65 cabinet
Fixed - Over/Under voltage limits, (0.75...1.2) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits
Features 71.11.8.230.0010 71.11.8.230.1010 1 - Phase 230 V Over & Under voltage monitoring relays 71.11.8.230.0010 - Fixed Over & Under voltage detection - Link selectable 5 or 10 minute lock-out delay
Remote Monitoring and REC 501 Control Unit Product Guide
Remote Monitoring and Control Unit REC 501 Product Guide Issued: May 1999 Status: Updated Version: B/06.11.2001 Data subject to change without notice Features Remote control and monitoring unit for the