1 control EPOS Positioning Controller Cable Starting Set Edition June /1 part number Positioning Controller Documentation Cable Starting Set
2 1 Table of contents 1 Table of contents Table of figures Introduction How to use this guide Cable selector EPOS 24/1 part number EPOS 24/1 with maxon DC motor with separated motor and encoder cable EPOS 24/1 with maxon DC motor with integrated motor / encoder ribbon cable EPOS 24/1 with maxon EC motor with separated motor and encoder cable RS-232 Communication CAN Communication EPOS power / signal cable (Connector J14) EPOS 24/1 DC motor cable (Connector J10) EPOS 24/1 motor / Hall sensor cable (Connector J10) EPOS encoder cable (Connector J11) EPOS RS232-COM cable (Connector J12) EPOS CAN-COM cable (EPOS 24/1 CAN Y-cable head A or B) EPOS 24/1 CAN Y-cable (Connector J13) EPOS CAN-CAN cable (EPOS 24/1 CAN Y-cable head A or B) EPOS CAN termination plug (EPOS 24/1 CAN Y-cable head A or B) EPOS 24/1 connector set Table of figures Figure 1: EPOS documentation hierarchy... 3 Figure 2: EPOS power / signal cable Figure 3: EPOS power / signal cable head A... 5 Figure 4: Pin assignment EPOS power / signal cable head A... 5 Figure 5: EPOS power / signal cable head B... 6 Figure 6: EPOS 24/1 DC motor cable Figure 7: EPOS 24/1 DC motor cable head A... 7 Figure 8: Pin assignment EPOS 24/1 DC motor cable head A... 7 Figure 9: EPOS 24/1 DC motor cable head B... 8 Figure 10: EPOS 24/1 motor / Hall sensor cable Figure 11: EPOS 24/1 motor / Hall sensor cable head A... 9 Figure 12: Pin assignment EPOS 24/1 motor / Hall sensor cable head A... 9 Figure 13: Motor cable head B Figure 14: Hall sensor cable head B Figure 15: EPOS encoder cable Figure 16: EPOS encoder cable head A Figure 17: Pin assignment EPOS encoder cable head A Figure 18: EPOS encoder cable head B Figure 19: Pin assignment EPOS encoder cable head B Figure 20: EPOS RS232-COM cable Figure 21: EPOS RS232-COM cable head A Figure 22: Pin assignment EPOS RS232-COM cable head A Figure 23: EPOS RS232-COM cable head B Figure 24: Pin assignment EPOS RS232-COM cable head B Figure 25: EPOS CAN-COM cable Figure 26: EPOS CAN-COM cable head A Figure 27: Pin assignment EPOS CAN-COM cable head A Figure 28: EPOS CAN-COM cable head B Figure 29: Pin assignment EPOS CAN-COM cable head B Figure 30: EPOS 24/1 CAN Y-cable Figure 31: Pin assignment EPOS 24/1 CAN Y-cable head A and B Figure 32: Pin assignment EPOS 24/1 CAN Y-cable head C Figure 33: EPOS CAN-CAN cable Figure 34: EPOS CAN-CAN cable head A Figure 35: Pin assignment EPOS CAN-CAN cable head A Figure 36: EPOS CAN-CAN cable head B Figure 37: Pin assignment EPOS CAN-CAN cable head B Figure 38: EPOS CAN termination plug Figure 39: Pin assignment EPOS CAN termination plug control Edition June 2006 / Subject to change
3 3 Introduction This documentation Cable Starting Set provides the wiring details from each EPOS cable. It contains pictures, drawings, cable specification, pin assignment and detailed connector information. The included Cable selector helps to choose the correct cable. The latest edition of these Cable Starting Set, additional documentation and software to the EPOS positioning controller may also be found on the internet in category <Service&Downloads>. 4 How to use this guide Setup Getting Started Installation Configuration Programming Application Cable Starting Set Graphical User Interface Windows DLL Application Notes Application Samples Hardware Reference IEC1131 Libraries Firmware Specification Communication Guide Figure 1: EPOS documentation hierarchy 3 control Edition June 2006 / Subject to change
4 5 Cable selector EPOS 24/1 part number EPOS 24/1 with maxon DC motor with separated motor and encoder cable EPOS power / signal cable (Connector J14).. order number EPOS 24/1 DC motor cable (Connector J10)... order number EPOS encoder cable (Connector J11) order number EPOS 24/1 with maxon DC motor with integrated motor / encoder ribbon cable EPOS power / signal cable (Connector J14).. order number EPOS encoder cable (Connector J11) order number EPOS 24/1 with maxon EC motor with separated motor and encoder cable EPOS power / signal cable (Connector J14) order number EPOS 24/1 motor / Hall sensor cable (Connector J10). order number EPOS encoder cable (Connector J11) order number RS-232 Communication EPOS RS232-COM cable (Connector J12) order number CAN Communication EPOS CAN-COM cable (EPOS 24/1 CAN Y-cable head A or B)... order number EPOS 24/1 CAN Y-cable (Connector J13). order number EPOS CAN termination plug (EPOS 24/1 CAN Y-cable head A or B).. order number Optional: EPOS CAN-CAN cable (EPOS 24/1 CAN Y-cable head A or B) order number control Edition June 2006 / Subject to change
5 6 EPOS power / signal cable (Connector J14) Order number: EPOS power / signal cable Figure 2: EPOS power / signal cable The EPOS power / signal cable is a 16 x 0.14 mm 2, 3 m length cable. Figure 3: EPOS power / signal cable head A The used Molex Micro-Fit 3.0 TM connector fits to EPOS 24/1 connector J14 Power / Signal Figure 4: Pin assignment EPOS power / signal cable head A 1 White D_Gnd Digital signal ground 2 Brown D_Gnd Digital signal ground 3 Green DigIN 6 Digital input 6 negative limit switch 4 Yellow DigIN 5 Digital input 5 positive limit switch 5 Grey DigIN 4 Digital input 4 Home switch 6 Pink DigIN 3 Digital input 3 general purpose 7 Blue DigIN 2 Digital input 2 general purpose 8 Red DigIN 1 Digital input 1 general purpose 9 Black +V OUT Auxiliary supply voltage Output (+5 VDC / 10mA) 10 Violet DigOUT 4 Digital output 4 general purpose 11 Grey-Pink DigOUT 3 Digital output 3 general purpose 12 Red-Blue +Vcc (9..24 VDC) Power supply voltage VDC 13 White-Green Power_Gnd Power Ground 14 Brown-Green A_Gnd Analogue signal ground 15 White-Yellow AnIN 2 Analogue input 2 16 Yellow-Brown AnIN 1 Analogue input 1 Connector: Molex Micro-Fit 3.0 TM 16 poles ( ) Crimp terminals: Molex Micro-Fit 3.0 TM female crimp terminals ( ) Hand crimper: Molex hand crimper (Europe: ; America: ) 5 control Edition June 2006 / Subject to change
6 Figure 5: EPOS power / signal cable head B Connect this cable end to the power supply and any used interface 1 White D_Gnd Digital signal ground 2 Brown D_Gnd Digital signal ground 3 Green DigIN 6 Digital input 6 negative limit switch 4 Yellow DigIN 5 Digital input 5 positive limit switch 5 Grey DigIN 4 Digital input 4 Home switch 6 Pink DigIN 3 Digital input 3 general purpose 7 Blue DigIN 2 Digital input 2 general purpose 8 Red DigIN 1 Digital input 1 general purpose 9 Black +VOUT Auxiliary supply voltage Output (+5 VDC / 10mA) 10 Violet DigOUT 4 Digital output 4 general purpose 11 Grey-Pink DigOUT 3 Digital output 3 general purpose 12 Red-Blue +Vcc (9..24 VDC) Power supply voltage VDC 13 White-Green Power_Gnd Power Ground 14 Brown-Green A_Gnd Analogue signal ground 15 White-Yellow AnIN 2 Analogue input 2 16 Yellow-Brown AnIN 1 Analogue input 1 Cable end sleeve: 0.14 mm 2 6 control Edition June 2006 / Subject to change
7 7 EPOS 24/1 DC motor cable (Connector J10) Order number: EPOS 24/1 DC motor cable Figure 6: EPOS 24/1 DC motor cable The EPOS 24/1 DC motor cable is a 2 x 0.25 mm 2, shielded, 3 m length cable. Figure 7: EPOS 24/1 DC motor cable head A The used Molex Micro-Fit 3.0 TM connector fits to EPOS 24/1 connector J10 Figure 8: Pin assignment EPOS 24/1 DC motor cable head A Colour Twisted Signal Pin White M+ + Motor terminal Brown M- - Motor terminal Connector: Molex Micro-Fit 3.0 TM 8 poles ( ) Crimp terminals: Molex Micro-Fit 3.0 TM female crimp terminals ( ) Hand crimper: Molex hand crimper (Europe: ; America: ) 7 control Edition June 2006 / Subject to change
8 Figure 9: EPOS 24/1 DC motor cable head B Connect this cable end to the DC motor Pin Colour Twisted Signal White M+ + Motor terminal Brown M- - Motor terminal Black Motor shield Cable shield Cable end sleeve (Motor): 0.25 mm 2 Cable end sleeve (Shield): 1.00 mm 2 Note: For EMC-compliant installation the cable shield should be connected to the motor housing. 8 control Edition June 2006 / Subject to change
9 8 EPOS 24/1 motor / Hall sensor cable (Connector J10) Order number: EPOS 24/1 motor / Hall sensor cable Figure 10: EPOS 24/1 motor / Hall sensor cable The EPOS 24/1 motor / Hall sensor cable is a 3 x 0.25 mm 2, shielded, 3 m length cable and a 5 x 0.14 mm 2, shielded, 3 m length cable. Figure 11: EPOS 24/1 motor / Hall sensor cable head A The used Molex Micro-Fit 3.0 TM connector fits to EPOS 24/1 connector J10 Figure 12: Pin assignment EPOS 24/1 motor / Hall sensor cable head A 1 White (0.14mm 2 ) Hall sensor 3 Hall sensor 3 Input 2 Brown (0.14mm 2 ) Hall sensor 2 Hall sensor 2 Input 3 Green (0.25mm 2 ) Motor winding 3 Winding 3 4 White (0.25mm 2 ) Motor winding 1 Winding 1 5 Grey (0.14mm 2 ) +V Hall Hall sensor supply voltage +5 VDC / 30 ma 6 Green (0.14mm 2 ) Hall sensor 1 Hall sensor 1 Input 7 Yellow (0.14mm 2 ) GND Ground of Hall supply 8 Brown (0.25mm 2 ) Motor winding 2 Winding 2 Connector: Molex Micro-Fit 3.0 TM 6 poles ( ) Crimp terminals: Molex Micro-Fit 3.0 TM female crimp terminals ( ) Hand crimper: Molex hand crimper (Europe: ; America: ) 9 control Edition June 2006 / Subject to change
10 Figure 13: Motor cable head B Connect this cable end to the EC motor Pin Colour Twisted Signal White Motor winding 1 Winding 1 Brown Motor winding 2 Winding 2 Green Motor winding 3 Winding 3 Black Motor shield Cable shield Cable end sleeve (Motor): 0.25 mm 2 Cable end sleeve (Shield): 1.00 mm 2 Note: For EMC-compliant installation the cable shield should be connected to the motor housing. Figure 14: Hall sensor cable head B Connect this cable end to the Hall sensor Pin Colour Twisted Signal Green Hall sensor 1 Hall sensor 1 Input Brown Hall sensor 2 Hall sensor 2 Input White Hall sensor 3 Hall sensor 3 Input Yellow GND Ground of Hall supply Grey +V Hall Hall sensor supply voltage +5 VDC / 30 ma Black Hall shield Cable shield Cable end sleeve (Hall): 0.14 mm 2 Cable end sleeve (Shield): 1.00 mm 2 Note: For EMC-compliant installation the cable shield should be connected to the motor housing. 10 control Edition June 2006 / Subject to change
11 9 EPOS encoder cable (Connector J11) Order number: EPOS encoder cable Figure 15: EPOS encoder cable The EPOS encoder cable is a 10 x AWG28, round-jacket, twisted pair flat cable, pitch 1.27 mm, 3.20 m length cable. Figure 16: EPOS encoder cable head A The used DIN female connector fits to EPOS 24/1 connector J11 Encoder Figure 17: Pin assignment EPOS encoder cable head A 1 Brown Pair 1 Motor + 1 DC motor: + Motor 2 White Pair 1 +5 VDC / 100 ma Encoder supply voltage 3 Red Pair 2 GND Ground 4 White Pair 2 Motor DC motor: - Motor 5 Orange Pair 3 Channel A\ Channel A complement 6 White Pair 3 Channel A Channel A 7 Yellow Pair 4 Channel B\ Channel B complement 8 White Pair 4 Channel B Channel B 9 Green Pair 5 Channel I\ Index complement 10 White Pair 5 Channel I Index Connector: DIN female connector, pitch 2.54 mm, 10 poles, plug strain relief 1 Only in use with maxon DC motors with integrated motor/encoder ribbon cable 11 control Edition June 2006 / Subject to change
12 Figure 18: EPOS encoder cable head B Connect this cable end to the encoder Figure 19: Pin assignment EPOS encoder cable head B 1 Brown Pair 1 Motor + 1 DC motor: + Motor 2 White Pair 1 +5 VDC / 100 ma Encoder supply voltage 3 Red Pair 2 GND Ground 4 White Pair 2 Motor - DC motor: - Motor 5 Orange Pair 3 Channel A\ Channel A complement 6 White Pair 3 Channel A Channel A 7 Yellow Pair 4 Channel B\ Channel B complement 8 White Pair 4 Channel B Channel B 9 Green Pair 5 Channel I\ Index complement 10 White Pair 5 Channel I Index Connector: DIN Plug, pitch 2.54 mm, 10 poles, plug strain relief Note: EPOS encoder cable head B, the pin out suits for example: - maxon digital MR-Encoder type S, M, ML, L all with Line Driver - maxon digital encoder HEDL 55_ with Line Driver RS Only in use with maxon DC motors with integrated motor/encoder ribbon cable 12 control Edition June 2006 / Subject to change
13 10 EPOS RS232-COM cable (Connector J12) Order number: EPOS RS232-COM cable Figure 20: EPOS RS232-COM cable The EPOS RS232-COM cable is a 2 x 2 x 0.14 mm 2, twisted pair, shielded, 3 m length cable. Figure 21: EPOS RS232-COM cable head A The used Molex Micro-Fit 3.0 TM connector fits to EPOS 24/1 connector J12 RS-232 Figure 22: Pin assignment EPOS RS232-COM cable head A Wire 1 Yellow Pair 1 EPOS RxD EPOS RS232 receive 2 White Pair 2 EPOS TxD EPOS RS232 transmit 3 Not connected 4 Green Pair 1 GND RS232_Ground 5 Brown Pair 2 GND RS232_Ground 6 Black Shield Cable shield Connector: Molex Micro-Fit 3.0 TM 6 poles ( ) Crimp terminals: Molex Micro-Fit 3.0 TM female crimp terminals ( ) Hand crimper: Molex hand crimper (Europe: ; America: ) 13 control Edition June 2006 / Subject to change
14 Figure 23: EPOS RS232-COM cable head B Connect this cable end to your COM interface Figure 24: Pin assignment EPOS RS232-COM cable head B 1 Not connected 2 White Pair 2 RS232 RxD COM RS232 receive 3 Yellow Pair 1 RS232 TxD COM RS232 transmit 4 Not connected 5 Brown Green Pair 2 Pair 1 RS232 GND RS232 GND COM RS232_Ground COM RS232_Ground 6 Not connected 7 Not connected 8 Not connected 9 Not connected x Shield Cable shield Soldered on connector housing Pin assignment according to RS-232 standard Connector: Female D-Sub connector DIN 41652, 9 poles, with mounting screws 14 control Edition June 2006 / Subject to change
15 11 EPOS CAN-COM cable (EPOS 24/1 CAN Y-cable head A or B) Order number: EPOS CAN-COM cable Figure 25: EPOS CAN-COM cable The EPOS CAN-COM cable is a 2 x 2 x 0.14mm 2, twisted pair, shielded, 3 m length cable. Figure 26: EPOS CAN-COM cable head A The used Molex Micro-Fit 3.0. TM connector fits to EPOS 24/1 CAN Y-cable (order number: ) Figure 27: Pin assignment EPOS CAN-COM cable head A 1 Yellow Pair 1 CAN high CAN high bus line 2 Green Pair 1 CAN low CAN low bus line 3 Brown CAN GND CAN Ground 4 Black CAN shield Cable shield Connector: Molex Micro-Fit 3.0 TM 4 poles ( ) Crimp terminals: Molex Micro-Fit 3.0 TM female crimp terminals ( ) Hand crimper: Molex hand crimper (Europe: ; America: ) 15 control Edition June 2006 / Subject to change
16 Figure 28: EPOS CAN-COM cable head B Connect this cable end to your CAN Master Figure 29: Pin assignment EPOS CAN-COM cable head B 1 Not connected 2 Green Pair 1 CAN low CAN low bus line 3 Brown CAN GND CAN Ground 4 Not connected 5 Shield CAN shield Cable shield 6 Not connected 7 Yellow Pair 1 CAN high CAN high bus line 8 Not connected 9 Not connected Pin assignment according to CiA DS102-2 Connector: Female D-Sub connector DIN 41652, 9 poles, with mounting screws 16 control Edition June 2006 / Subject to change
17 12 EPOS 24/1 CAN Y-cable (Connector J13) Order number: EPOS 24/1 CAN Y-cable Figure 30: EPOS 24/1 CAN Y-cable The EPOS 24/1 CAN Y-cable consist of 50mm long single with cross section of 0.14mm 2 Head A / Head B The used Molex Micro-Fit 3.0 TM connector fits to: - EPOS CAN-COM cable (#275908) head A - EPOS CAN-CAN cable (#275926) - EPOS CAN termination plug (#275937) Head C The used Molex Micro-Fit 3.0 TM connector fits to EPOS 24/1 connector J13 CAN Figure 31: Pin assignment EPOS 24/1 CAN Y-cable head A and B Figure 32: Pin assignment EPOS 24/1 CAN Y-cable head C Pin Colour Signal Pin Colour Signal 1 Green CAN low 1 Yellow CAN high 2 Yellow CAN high 2 Green CAN low 3 Black CAN shield 3 Brown CAN GND 4 Brown CAN GND 4 Black CAN shield Connector: Molex Micro-Fit 3.0. TM 4 poles ( ) Crimp terminals: Molex Micro-Fit 3.0 TM male crimp terminals ( ) Hand crimper: Molex hand crimper (Europe: ; America: ) Connector: Molex Micro-Fit 3.0. TM 4 poles ( ) Crimp terminals: Molex Micro-Fit 3.0 TM female crimp terminals ( ) Hand crimper: Molex hand crimper (Europe: ; America: ) 17 control Edition June 2006 / Subject to change
18 13 EPOS CAN-CAN cable (EPOS 24/1 CAN Y-cable head A or B) Order number: EPOS CAN-CAN cable Figure 33: EPOS CAN-CAN cable The EPOS CAN-CAN cable is a 2 x 2 x 0.14mm 2, twisted pair, shielded, 3 m length cable. Figure 34: EPOS CAN-CAN cable head A The used Molex Micro-Fit 3.0. TM connector fits to EPOS 24/1 CAN Y-cable (order number: ) Figure 35: Pin assignment EPOS CAN-CAN cable head A 1 Yellow Pair 1 CAN high CAN high bus line 2 Green Pair 1 CAN low CAN low bus line 3 Brown CAN GND CAN Ground 4 Shield CAN shield Cable shield Connector: Molex Micro-Fit 3.0. TM 4 poles ( ) Crimp terminals: Molex Micro-Fit 3.0 TM female crimp terminals ( ) Hand crimper: Molex hand crimper (Europe: ; America: ) 18 control Edition June 2006 / Subject to change
19 Figure 36: EPOS CAN-CAN cable head B The used Molex Micro-Fit 3.0. TM connector fits to EPOS 24/1 CAN Y-cable (order number: ) Figure 37: Pin assignment EPOS CAN-CAN cable head B Wire 1 Yellow Pair 1 CAN high CAN high bus line 2 Green Pair 1 CAN low CAN low bus line 3 Brown CAN GND CAN Ground 4 Shield CAN shield Cable shield Connector: Molex Micro-Fit 3.0 TM 4 poles ( ) Crimp terminals: Molex Micro-Fit 3.0 TM female crimp terminals ( ) Hand crimper: Molex hand crimper (Europe: ; America: ) 19 control Edition June 2006 / Subject to change
20 14 EPOS CAN termination plug (EPOS 24/1 CAN Y-cable head A or B) Order number: EPOS CAN termination plug Figure 38: EPOS CAN termination plug The used Molex Micro-Fit 3.0. TM connector fits to EPOS 24/1 CAN Y-cable (order number: ) Figure 39: Pin assignment EPOS CAN termination plug 1 Resistor terminal Ohm bus termination 2 Resistor terminal Ohm bus termination 3 Not connected 4 Not connected Connector: Molex Micro-Fit 3.0. TM 4 poles ( ) Crimp terminals: Molex Micro-Fit 3.0 TM female crimp terminals ( ) Hand crimper: Molex hand crimper (Europe: ; America: ) 20 control Edition June 2006 / Subject to change
21 15 EPOS 24/1 connector set Order number: EPOS 24/1 connector set Complete connecter set contains: Connector Specification Number J10 Molex Micro-Fit 3.0 TM 8 poles ( ) 1 J12 Molex Micro-Fit 3.0 TM 6 poles ( ) 1 J13 Molex Micro-Fit 3.0 TM 4 poles ( ) 1 J14 Molex Micro-Fit 3.0 TM 16 poles ( ) 1 Molex Micro-Fit 3.0 TM female crimp terminals ( ) 40 Tyco C42334-A421-C42 (right), encoder clip right 1 Tyco C42334-A421-C52 (left), encoder clip left 1 Useful accessories (not available at ag): Hand crimper : Molex hand crimper (Europe: ; America: ) 21 control Edition June 2006 / Subject to change
maxon sensor maxon sensor
Sensor Spindle drive Gearhead E Motor (BLD Motor) D Motor X Drives (configurable) Motor control obust encoders, D tachometers, and resolvers with high accuracy and high signal resolution. Due to resonance,
Gold Eagle HV Gold Eagle HV Cable Kit (EtherCAT and CAN)
Gold Eagle HV Gold Eagle HV Cable Kit (EtherCAT and CAN) January 2014 (Ver. 1.000) Notice This guide is delivered subject to the following conditions and restrictions: This guide contains proprietary information
Gold Cello Gold Cello Cable Kit
Gold Cello Gold Cello Cable Kit January 2014 (Ver. 1.101) Notice This guide is delivered subject to the following conditions and restrictions: This guide contains proprietary information belonging to Elmo
TECHNICAL DATASHEET Incremental Encoder RI 80-E
Incremental 30-45 hollow shaft Rugged mechanical design Unbreakable disc Integrated diagnostic system Wide voltage range DC 5-30 V Isolated shaft NUMBER OF PULSES 1024 / 2048 / 2500 / 4096 / 5000 / 10000
TECHNICAL DATASHEET Incremental Encoder RI 58-D / RI 58TD
Direct mounting without coupling Flexible hollow shaft design up to diameter 4 mm Through hollow shaft or as end shaft (blind shaft) Easy installation by means of clamping shaft or blind shaft Short overall
Gold Solo Whistle Cable Kit
Gold Solo Whistle Cable Kit March 2014 (Ver. 1.201) Notice This guide is delivered subject to the following conditions and restrictions: This guide contains proprietary information belonging to Elmo Motion
Encoders. the incremental encoders format such as relective optical technology, transmissive optical technology
the incremental encoders format such as relective optical technology, transmissive optical technology back devices, brakes and gearboxes at no extra cost to you. USA: +1 267 933 2105 Europe: +33 20928751
MILE Encoder for EC 90 flat
MILE Encoders Edition October 2014 MILE Encoder for EC 90 flat Encoders Document ID: 1 495 818-06 ag Brünigstrasse 220 P.O.Box 263 CH-6072 Sachseln Phone +41 41 666 15 00 Fax +41 41 666 16 50 www.maxonmotor.com
Housing diameter Shaft diameter 1. Flange (Mounting of housing) Protection class shaft input (EN 60529) Protection class housing (EN 60529)
Direct mounting without coupling Flexible hollow shaft design up to diameter 4 mm Through hollow shaft or as end shaft (blind shaft) Easy installation by means of clamping shaft or blind shaft Short overall
ViZion Installation Guide
ViZion Installation Guide v2.0 1 ViZion Installation Guide Table of Contents Inventory Hardware Setup Understanding Synchronization Cable Begin by taking an inventory of the required equipment DR Unit
Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP
Product Information Gateway For Connecting EnDat Encoders to PROFIBUS-DP April 2012 PROFIBUS Gateway For Connecting EnDat Encoders Encoders with EnDat interface for connection via gateway All absolute
zamak nitrile rubber self-extinguishing technopolymer aluminum
PS COMBOBOX valves - Valves with compact design: valve body with integrated sub-base - High flexibility: > possibility of choosing fitting dimension (--) according to users needs > manifolds from up to
zamak nitrile rubber selfestinguishing technopolymer aluminum B10 24 V DC (± 10%) holding 0,32 W, pick-up 5,5 W (25 ms) IP65 button with tool
P0 0mm COMPCT valves - threaded body and for sub-base mounting - Low standard power consumption (0,W): low power consumption electropilot B0 (standard version with LED) - Quick response times - High flow
TECHNICAL DATASHEET Incremental Encoder RI 58-O / RI 58-T
Universal industry standard encoder Up to 40 000 steps with 0 000 pulses High signal accuracy Protection class up to IP67 Flexible due to many flange and configuration variants Suitable for high shock
INDUSTRIAL AUTOMATION CONNECTOR SYSTEMS
INDUSTRIAL AUTOMATION CONNECTOR SYSTEMS CONNECTING TOMORROW'S TECHNOLOGY, TODAY. 2 BRAD HARRISON AND MPM CONNECTOR SYSTEMS Brad Harrison originally started manufacturing moulded connectors in 1946 for
IP40 or IP64 (EN 60529) Protection class housing. IP50 (IP65 optional) (EN 60529) Minimum length of mountig
Through hollow shaft Ø 5 bis 4 mm Outside diameter only 76 mm Easy installation by means of clamping ring front or rear Operating temperature up to 00 C Applications: motors, printing machines, lifts NUMBER
ABB Drives. User s Manual HTL Encoder Interface FEN-31
ABB Drives User s Manual HTL Encoder Interface FEN-31 HTL Encoder Interface FEN-31 User s Manual 3AUA0000031044 Rev B EN EFFECTIVE: 2010-04-06 2010 ABB Oy. All Rights Reserved. 5 Safety instructions
Comtrol Cable User Guide
Comtrol Cable User Guide Trademark Notices Comtrol and DeviceMaster are trademarks of Comtrol Corporation. PortVision is a registered trademark of Comtrol Corporation. Microsoft and Windows are registered
zamak nitrile rubber self-extinguishing technopolymes aluminum
G 0 mm - G / Valves and solenoid valves - G/ threaded valve body with traditional Univer spool system - Version with integrated connection and esternal connection - Compact design - High flow rate - Versions
HSG Engineering Tech Bulletin
Specifications subject to change OCT 2013; Rev. 1.3 HSG Engineering Tech Bulletin Recommended RS-485 Wiring for NetAXS-4/NetAXS-123 Loops Overview This document provides the recommended RS-485 wiring for
Series LC6D/LC6C. To power supply PLC. LC6C dedicated teaching box P.971. Options P.973
Series LCD To power supply Electric Actuator Series LCC Stepper Motor Driver LCD Series LX Dedicated Stepper Motor Driver and Positioning Driver Series LCD/LCC PLC Positioning unit (Not incl. To be provided
Positioning Controller
Edition May 2008 Positioning Controller Application Note "CANopen Basic Information" Edition May 2008 EPOS 24/1, EPOS 24/5, EPOS 70/10, MCD EPOS 60W, EPOS2 50/5 Firmware version 2000h or higher Introduction
Installation Manual (English) Adjustable Active DP Terminator T1-Pepper Active RS485 segment termination for non-compliant cable
Installation Manual (English) Adjustable Active DP Terminator T1-Pepper Active RS485 segment termination for non-compliant cable Designed for use with the COMbricks SALT repeater All baudrates Redundant
Installation Fleet Tracker (SBC3)
Installation Fleet Tracker (SBC3) VERSION DATUM AUTOR DATEINAME 1.0 1. NOVEMBER 2011 SM EINBAU FLOTTENSBC3_ENGLISCH_V10.DOCX The installation should be done by qualified personnel, who is experienced in
GARMIN GPS to PC Wiring Instructions
GARMIN GPS to PC Wiring Instructions Introduction This will outline the basics for connecting most GARMIN GPS receivers to a PC serial connector for data transfer. Since the GPS needs to both send and
Series 7500 Torque Sensor
Properties PTO (Power Take-Off) shaft with integrated torque and angle measurement Non-contact measurement system, high robustness Plug & Play solution, no additional electronics required Performance Measurement
CAUTION! THE 7I29 USES VOLTAGE AND POWER LEVELS THAT REPRESENT A HAZARD TO LIFE AND LIMB.
7I29 MANUAL Rev 1.5 CAUTION! THE 7I29 USES VOLTAGE AND POWER LEVELS THAT REPRESENT A HAZARD TO LIFE AND LIMB. THE 7I29 IS INTENDED FOR USE BY OEMS THAT WILL INTEGRATE IT INTO A SYSTEM WITH INTERLOCKS AND
SV 210 Signal Splitter and Incremental Converter for Sine-Cosine Encoders
control motion interface motrona GmbH Zwischen den Wegen 32 78239 Rielasingen - Germany Tel. +49 (0)7731-9332-0 Fax +49 (0)7731-9332-30 [email protected] www.motrona.com SV 210 Signal Splitter and Incremental
RC2200DK Demonstration Kit User Manual
Demonstration Kit User Manual Table of contents TABLE OF CONTENTS... 1 QUICK INTRODUCTION... 2 INTRODUCTION... 3 DEMONSTRATION BOARD... 4 POWER SUPPLY SECTION... 5 RS-232 INTERFACE... 6 CONNECTORS... 7
MultiViu Flex 7 Data Sheet
Division Interior MultiViu Flex 7 Data Sheet Picture: MultiViu Flex 7 Picture: MultiViu Flex 7 Description CAN-capable multifunction Solution Features: Robust and versatile design CAN-capability (SAE J1939,
RS232C < - > RS485 CONVERTER S MANUAL. Model: LD15U. Phone: 91-79-4002 4896 / 97 / 98 (M) 0-98253-50221 www.interfaceproducts.info
RS232C < - > RS485 CONVERTER S MANUAL Model: LD15U INTRODUCTION Milestone s model LD-15U is a RS232 to RS 485 converter is designed for highspeed data transmission between computer system and or peripherals
WEB log. Device connection plans
WEB log LIGHT+ 20 BASIC 100 PRO unlimited Device connection plans Version 20151210* Copyright Copyright for this manual remains with the manufacturer. No part of this manual may be reproduced or edited,
Datasheet of the Easy Servo Motor ES-M Series
Datasheet of the Easy Servo Motor ES-M Series Stepper Motor with Encoder, 0.9-8 Nm Version 1.3 http://www.leadshine.com Descriptions Leadshine s ES-M series easy servo motors, or stepper motors with encoders,
MechoNet TM Network Interface (MNI) Specification Submittal
MechoNet TM Network Interface (MNI) Specification Submittal Models MechoNet Network Interface: MNI RJ (RJ45 Motor Ports): Stock No.: IMNI 0001 TP AS (US version) Stock No.: IMNI 0004 TP AS (UK version)
Technical Data Sheet OPUS A3 STANDARD Full TDS OPUS A3sF, 03.09.2012
Technical Data Sheet OPUS A3 STANDARD Full TDS OPUS A3sF, 03.09.2012 OPUS A3 Standard Full Landscape OPUS A3 Standard Full Neutral 1 Order Numbers OPUS A3 STANDARD Full Wachendorff Projektor Landscape
LocoNet, the Digitrax Difference
LocoNet, the Digitrax Difference LocoNet is Digitrax's method of communication between LocoNet compatible devices on a model railroad layout. LocoNet Compatible devices are designed to work together on
ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01
ABB Drives User s Manual Pulse Encoder Interface Module RTAC-0 Pulse Encoder Interface Module RTAC-0 User s Manual 3AFE 64486853 REV A EN EFFECTIVE:.5.00 00 ABB Oy. All Rights Reserved. Safety instructions
ISO 15407-1/2 (VDMA 24563) ISO 02 (18 mm) - ISO 01 (26 mm) Valves
BD ISO 0/ (VDM ) ISO 0 ( mm) ISO 0 ( mm) Valves BDE = solenoid valves ISO 0/ with integrated connection including V DC coils and connector BDB = solenoid valves ISO 0/ with external connection with M connector
IMMS-CCC. IMMS-CCC Hardwire Central Interface. Installation Instructions
IMMS-CCC IMMS-CCC Hardwire Central Interface Installation Instructions TABLE OF CONTENTS... Choose a Location... 1 Connections... 2 Operations... 3 Software Configuration... 4 Troubleshooting... 5 Loopback
Making a DB to RJ45 adapter.
Making a DB to RJ45 adapter. DB9 to RJ45 adapters are often used in combination with a RS232 repeater for extending the distance of a serial RS232 link, but can be used for any adapter or converter purposes.
Datasheet of the Easy Servo Motor ES-MH Series
Datasheet of the Easy Servo Motor ES-MH Series High Voltage Stepper Motor with Encoder, 8-20 Nm Version 1.4 http://www.leadshine.com Descriptions Leadshine s ES-MH series easy servo motors, or stepping
X8 Option 2 - Technology
moog AC DC AC 4 to 450 A 4 to 210 A Compact MSD Servo Drive TTL in out Specification X8 Option 2 - Technology TTL Encoder Simulation / TTL Master Encoder moog Specification Option 2 - Technology TTL encoder
ECR Shelf System Installation Guide Centralized Rack Mount Call Recording
Hardware & Installation Guide Algo Communication Products Ltd. Customer Support and Sales Tel: 1.877.884.2546 Fax: 604.437.5726 Email: [email protected] [email protected] www.algosolutions.com
ALL-USB-RS422/485. User Manual. USB to Serial Converter RS422/485. ALLNET GmbH Computersysteme 2015 - Alle Rechte vorbehalten
ALL-USB-RS422/485 USB to Serial Converter RS422/485 User Manual ALL-USB-RS422/485 USB to RS-422/485 Plugin Adapter This mini ALL-USB-RS422/485 is a surge and static protected USB to RS-422/485 Plugin Adapter.
POINTS POSITION INDICATOR PPI4
POINTS POSITION INDICATOR PPI4 Advanced PPI with Adjustable Brightness & Simplified Wiring Monitors the brief positive operating voltage across points motors when they are switched Lights a corresponding
Mobile Satellite Solutions. A WiWorld Partner SATELLITE TV ANTENNA CONTROLLER RFM-1000/1100 TECHNICAL MANUAL STOW SEARCH
Mobile Satellite Solutions A WiWorld Partner SATELLITE TV ANTENNA CONTROLLER RFM-1000/1100 TECHNICAL MANUAL SEARCH STOW Ver. 1 June 2012 WARNING Make all electrical and coax connections from the controller
Electronic Control Devices The European Product Catalogue 2007
FX14 Field Controller (1/4) FX14 Field Controller The FX14 is an equipment field controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating,
Installation Fleet Tracker (SBC3)
Installation Fleet Tracker (SBC3) VERSION DATUM AUTOR DATEINAME 1.1 21. MAI 2012 SM EINBAU FLOTTENSBC3_ENGLISCH_V11.DOCX The installation should be done by qualified personnel, who is experienced in dealing
SVC400P/SVC800P. 4/8 Camera Live Tracking Vehicle DVR Installation Manual. Version 1.0
SVC400P/SVC800P 4/8 Camera Live Tracking Vehicle DVR Installation Manual Version 1.0 1. MAIN FEATURES... 2 2. PRODUCT OVERVIEW... 2 3. DIMENSIONS... 4 4. PACKAGE CONTENTS... 5 5. MOUNTING AND ENVORNMENTAL
TECHNICAL DATASHEET Incremental Encoder RI 58-H
Through hollow shaft High accuracy by means of integrated flexible coupling Safe shaft mounting Applications: textile machines, motors, drives, copiers NUMBER OF PULSES 1 / 2 / 3 / 4 / 5 / 10 / 15 / 20
EPIC CIRCON M23 Series Circular Signal Connectors
Circular Signal Connectors CIRCON M2 circular signal connectors are designed to DIN specification N698 and have a standard M2 threaded connection housing. They are offered in coupler, connector, and panel
How To Power A Schen
Automation / Mini Type SCH32F Hollow Shaft Encoder - Ø 32 mm Hollow Bore: Ø 6 mm to Ø 3/8 inch Resolution up to 5000 ppr IP 65 (IP 50 for IDC connector option) Electrical Specifications Code: Resolution:
16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide
16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide 1. Introduction Thank you for purchasing this 16-Port RS232 to USB2.0 High Speed Multi Serial Adapter. It is an
Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:
Automation / Mini Type SCH32F Hollow Shaft Encoder - Ø 32 mm Hollow Bore: Ø 6 mm to Ø 3/8 inch Resolution up to 5000 ppr IP 65 (IP 50 for IDC connector option) Electrical Specifications Code: Resolution:
Contents. : AEOS Blue cabling and technical aspects. NEDAP N.V. IDEAS Information Bulletin No: H032. Date : 12 January 2016
NEDAP N.V. IDEAS Information Bulletin No: H032 Date : 12 January 2016 Concerns : AEOS Blue cabling and technical aspects AEOS Blue units can easily be connected to each other using the 485bus. This document
EZmoto V2. Product description Rev. 6 10/01/2014. EZmoto V2 Product description Rev.6 10/01/2014
EZmoto V2 Product description Rev. 6 10/01/2014 1 Contents 1. Overview... 3 2. Hardware Interface Description... 3 2.1 Main features of the EZmoto... 3 2.2 Hardware block diagram... 4 2.3 Internal Hardware
PCAN-B10011S Bus Converter High-speed CAN to Truck Trailer CAN. User Manual. Document version 2.1.0 (2013-11-15)
PCAN-B10011S Bus Converter High-speed CAN to Truck Trailer CAN User Manual Document version 2.1.0 (2013-11-15) Products taken into account Product Name Model Part number PCAN-B10011S IPEH-002041 CANopen
Points Position Indicator (PPI1) for Points Motors with Common Ground
Points Position Indicator (PPI1) for Points Motors with Common Ground Monitors Points Action and Operates Leds on a Control Panel Monitors the brief positive operating voltage across points motors when
Directory chapter 04
M Directory chapter 04 D-Sub Mixed subminiature D connectors New Page D-Sub mixed connector system general information................... 04.02 Contact arrangements............................................
1-Port R422/485 Serial PCIe Card
1-Port R422/485 Serial PCIe Card Installation Guide 1. Introduction Thank you for purchasing this 1-Port RS422/485 Serial PCI Express (PCIe) Card. It is a universal add in card that connects to a PC or
Cable Plug acc. to DIN EN 175301-803, Form A
Cable Plug acc. to DIN EN 175301-803, Form A Complete program Contact form 18 mm Also available with LED indicator Optional 4-pin version for pressure switch or impulse valves respectively Versions with
ALARMS-xx. Remote Alarm Unit Setup Guide 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 RESET ALL
Remote Alarm Unit Setup Guide 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 RESET ALL User s Guide Version 1.0 07/01/2009 Michael Stevens & Partners Ltd. has made
Data Bulletin. Communications Wiring for POWERLINK G3 Systems Class 1210 ABOUT THIS BULLETIN APPLICATION INTRODUCTION.
Data Bulletin 1210DB0002R3/05 03/2005 LaVergne, TN, USA Communications Wiring for POWERLINK G3 Systems Class 1210 Retain for future use. ABOUT THIS BULLETIN This data bulletin describes the proper wiring
www.sebury.com.cn Digital Keypad Use s Manual
K3 K4 www.sebury.com.cn Digital Keypad Use s Manual Contents Introduction Introduction Specifications Intramural Interface Circuit 3 Mounting 3 Wiring 5 Power UP 7 Engineer Programming Mode 7 The K3/K4
DCP Fan Controller. Version 01/2009. The engineer s choice
Version 01/2009 The engineer s choice Index Page 1. Introduction... 3 2. Technical specification... 4 3. Connection diagrams... 9 4. Configuration... 10 5. Compatible ebm-papst Fan List... 11 2 1. Introduction
PCAN-MicroMod Evaluation Test and Development Environment for the PCAN-MicroMod. User Manual. Document version 2.0.1 (2013-08-06)
PCAN-MicroMod Evaluation Test and Development Environment for the PCAN-MicroMod User Manual Document version.0. (0-0-0) Products taken into account Product Name Part number Model PCAN-MicroMod Evaluation
Inwall 4 Input / 4 Output Module
Inwall 4 Input / 4 Output Module IO44C02KNX Product Handbook Product: Inwall 4 Input / 4 Output Module Order Code: IO44C02KNX 1/27 INDEX 1. General Introduction... 3 2. Technical data... 3 2.1 Wiring Diagram...
RS-232 COMMUNICATIONS
Technical Note D64 0815 RS-232 COMMUNICATIONS RS-232 is an Electronics Industries Association (EIA) standard designed to aid in connecting equipment together for serial communications. The standard specifies
USB to RS-422/485 Serial Adapter
USB to RS-422/485 Serial Adapter User Manual Ver. 2.00 All brand names and trademarks are properties of their respective owners. Contents: Chapter 1: Introduction... 3 1.1 Product Introduction... 3 1.2
EUROMAP 66-1. Protocol for Communication with Peripheral Equipment. General Description
EUROMAP 66-1 Protocol for Communication with Peripheral Equipment General Description Version 1.2, December 2002 (10 pages) This recommendation was prepared by the Technical Commission of EUROMAP. History
connecdim Gateway G1 Ethernet TCP/IP to DALI
Gateway G1 Ethernet TCP/IP to LI Independent lighting control for up to 256 LI gears on 4 LI lines Can be expanded by connecting multiple gateways on the same network Cloud based web interface for configuration
Index. ROPIX P18 Hardware... 3. ROPIX P18 Software... 12 ROPIX P18
Index ROPIX P18 Hardware... 3 I. ROPIX P18 Profile Overview... 3 II. Parameter... 5 Sending Card... 6 Receiving Card... 8 Maintenance Tools... 8 III. ROPIX P18 Installation... 9 Cabinet Assembly... 9 Controlling
Vibration Monitoring System Adash 3600
" User's guide Application: Vibration Monitoring System Adash 3600! Vibration diagnostics, monitoring and protective on-line system! On-line vibration monitoring system of engines, fans, pumps, gearboxes,
MCT-7 Multiple Cable Test System
www.whirlwindusa.com MCT-7 Multiple Cable Test System INTRODUCTION: The MCT-7 Cable Tester is a versatile unit that allows the user to test almost any pre-made and custom made leads or cables used in a
Single sub-base valve
solenoid valves Mini-valves 10 mm Electrical connection... Mounting... Port sizes... Rated temperature... Fluid... Working pressure... Nominal flow... Pneumatic connections Voltage... Power... NC poppet
6 mm (Synchronus flange) 10 mm (Clamp flange) 10 / 12 mm (Plug shaft) axial 40 N, radial 60 N (10, 12 mm Shaft) Operating speed 10 000 min -1
Absolut Encoder BC 58 Singleturn / Multiturn short cicurit-proof Parallel, SSI, Profibus DP, Interbus (K2) (K3) DeviceNet, CAN, CANopen, Mechanical Specifications: (Synchronus flange) (Clamp flange) 10
Instruction Sheet ACS-101. General Description. Specifications. Amplified Broadband UHF Combiner-Splitter. Overall. Antenna Splitter.
ACS-101 Amplified Broadband UHF Combiner-Splitter General Description The ACS-101 (Antenna Combiner Splitter 10 to 1) is an amplified and filtered broadband splitter-combiner. It allows up to 10 base stations
Pmod peripheral modules are powered by the host via the interface s power and ground pins.
Digilent Pmod Interface Specification Revision: November 20, 2011 1300 NE Henley Court, Suite 3 Pullman, WA 99163 (509) 334 6306 Voice (509) 334 6300 Fax Introduction The Digilent Pmod interface is used
ABLOY DA60 SWING DOOR OPERATOR Installation and commissioning manual Abloy Oy An ASSA ABLOY Group company APPROVALS / STANDARDS Low Voltage directive 7//EEC as amended by the directive 9/68/EEC EMC directive
Technical Data Sheet OPUS A6 STANDARD Basic TDS OPUS A6sB, 02.10.2012
Technical Data Sheet OPUS A6 STANDARD Basic TDS OPUS A6sB, 02.10.2012 OPUS A6 STANDARD Basic Landscape OPUS A6 STANDARD Basic Landscape/Portrait 1 Order Numbers OPUS A6 STANDARD Full Wachendorff Projektor
2-Port RS232/422/485 Combo Serial to USB2.0 Adapter (w/ Metal Case and Screw Lock Mechanism) Installation Guide
2-Port RS232/422/485 Combo Serial to USB2.0 Adapter (w/ Metal Case and Screw Lock Mechanism) Installation Guide 1. Introduction Thank you for purchasing this 2-Port RS232/422/485 Combo Serial to USB Adapter.
HF series Hall effect joysticks
Distinctive features and specifications 1, 2 & 3 axis configurations Dual sensors for redundancy CANbus J1939 and CANopen options Voltage regulator, 24V supply option USB 1.1 HID interface option ized
QUICK INSTALLATION. MSX-E1516 Ethernet digital I/O system 02.04-08/2014
QUICK INSTALLATION MSX-E1516 Ethernet digital I/O system 02.04-08/2014 Addi-data GmbH Airpark Business Center Airport Boulevard B210 77836 Rheinmünster Germany Tel: +49 7229 1847-0 Fax: +49 7229 1847-200
HARAX circular connector
Show navigation HARAX circular connector Technical characteristics Specifications IEC 60 352-4 IEC 60 9475-2 Approvals HARAX M8-S/M12-S Rated voltage Rated current Diameter of individual strands Conductor
Copyrights 2010 Victron Energy B.V. All Rights Reserved
Manual EN 1 Copyrights 2010 Victron Energy B.V. All Rights Reserved This publication or parts thereof may not be reproduced in any form, by any method, for any purpose. For conditions of use and permission
Touch Screen for Pictiva OLED display. Application Note. Introduction
Touch Screen for Pictiva OLED display Application Note AN0 Introduction A touch screen interface can be added to Pictiva.7 inch or similar OLED displays to enhance its operation. This application note
Advanced Data Capture and Control Systems
Advanced Data Capture and Control Systems Tronisoft Limited Email: [email protected] Web: www.tronisoft.com RS232 To 3.3V TTL User Guide RS232 to 3.3V TTL Signal Converter Modules P/N: 9651 Document
VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control
VP, -way proportional pressure control valves > > Port size: G/... G/ > > All-digital control electronics > > Variable pressure control > > Optional actuation via fieldbus (separate datasheet on request)
Manual Serial PCI Cards
Manual Serial PCI Cards W&T Models 13011, 13410 13411, 13610 13611, 13812 Version 1.4 Subject to error and alteration 37 01/2005 by Wiesemann & Theis GmbH Subject to errors and changes: Since we can make
Cables. 1.888.KEITHLEY (U.S. only) www.keithley.com ACCESSORIES
Model Description Type TERMINATIONS LENGTH From To m ft USE WITH: 236-ILC-3 Safety Interlock Shielded twisted pair 3-pin round 3-pin round 3 10 237, 4200-SCS, 8007, 8008 237-ALG-2 Low Noise Input Triax
Product Information. HMC 6 Hybrid Motor Cable
Product Information HMC 6 Hybrid Motor Cable November 2014 HMC 6 Single-cable solution for servo drives Motors normally need two separate cables: One cable for the motor encoder One cable for the motor
Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5
Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service program ULTRA 000 programmable switch outputs Hysteresis
INSTALLATION MANUAL XM3 Reader
INSTALLATION MANUAL XM3 Reader Conditions Transactions, deliveries et cetera will be according to the general terms of delivery as deposited at the Chamber of Commerce at Meppel, The Netherlands. Registration
LED red (-): Measuring value < lower tolerance threshold LED red (+): Measuring value > upper tolerance threshold. Page 1/6
L-LAS Series L-LAS-LT-165-CL - Line laser 1 mw, laser class 2 - Visible laser line (red light 670 nm), typ. 2 mm x 3 mm - Reference distance approx. 165 mm - Measuring range typ. 65... 265 mm - Resolution
Table of Contents. General Operation 2. Air Blast Cleaning System 3. Setup 4. Changing Ticket Bags 5. Loading Printer Paper 6. Tower Light Status 7
Table of Contents General Operation Air Blast Cleaning System Setup Changing Ticket Bags Loading Printer Paper Tower Light Status Ticket Taker General - Ticket Taker Overview - Ticket Taker Operation Clearing
QR12 (1.22 ) Diameter Optical Encoder
Improving the Quality of Life through the Power in Light QPhase QR12 (1.22 ) Diameter Optical Encoder Design Features: Low profile assembled height of Bearing design simplifies encoder attachment Resolutions
TX OPEN RS232/485 module
s 8 185 8185P01 TX-I/O ; DESIGO OPEN TX OPEN RS/485 module for integrating third-party systems and devices to DESIGO (V4 or higher) TXI1.OPEN Platform to integrate third-party systems and devices to the
HSP GmbH Zum Handwerkerhof 2 90530 Wendelstein Tel. 09129 / 2852-0 Fax: 09129 / 2852-11 Web: www.hsshsp.de EMAIL: [email protected] NTG-3000.
NTG-3000 Transducer Data Sheet Document Version 2.8 Page 1 of 10 Versions / Revisions: Document Creation Author Description version date 2.0 2012-07-25 P. Compensis First official version 2.1 2012-08-24
Color Mark Sensor with Red or Green LED E3S-VS
Color Mark Sensor with Red or Green LED Rugged IP67 Color Mark Sensor 1 ms response time Detects a wide variety of color marks PNP or NPN output ls Light-on/ Dark-on operation, wire selectable Vertical
ARDUINO SEVERINO SERIAL SINGLE SIDED VERSION 3 S3v3 (REVISION 2) USER MANUAL
ARDUINO SEVERINO SERIAL SINGLE SIDED VERSION 3 S3v3 (REVISION 2) USER MANUAL X1: DE-9 serial connector Used to connect computer (or other devices) using RS-232 standard. Needs a serial cable, with at least