NYCY 0,6/1kV DIN VDE , DIN VDE

Similar documents
CONFLEX ELECTRIC CABLE

VIPERFLEX ELECTRIC CABLE

Fire retardant IEC

FLEXIBLE INDUSTRIAL CABLES H07RN-F TENAFLEX SR

ENERGY. TECWATER S1BN8-F 0,6/1 kv. Cable for Water Application

VDE-approved PVC-Control Cables

We specialize in low voltage cables including: Stranded Single Cable H07V-R Flexible Single Cable H05V-K

The Quality Connection. BETAflam Fire Resistant Safety Cables

ISO 9001 ISO CABLES AND WIRES CATALOGUE 2008

Flexible Control Cables

Chemical resistance Accidental

Gulf Cable & Electrical Ind. Co.

MV CABLE TYPE C

Flexible cables for submersible products

with coloured cores and overall copper screen UL/CSA... 17

High Voltage Systems. Today. The history of cables

Festoon 715 P PUR cable for flexible application in festoon systems

Power and Wiring Cables

PROFIBUS cable. for PROFIBUS-PA and -DP 10/ EN

MEDIUM VOLTAGE CABLES Up to and including 36 KV

ENERGY. TECSUN DUO (PV) Twin Cables for Photovoltaics

THE WAY FOR ENERGY HALOGEN FREE, LOW SMOKE AND FIRE RESISTANT CABLES

RELIABLE AND EFFICIENT MINING MINING CABLES

KNOW YOUR OPTIONS: 230 KV POWER CABLES

Tri-Rated Flexible PVC Equipment Wire

CABLES FOR PHOTOVOLTAIC SOLAR ENERGY INSTALLATIONS FOR CLEAN ENERGY

Current Ratings. TABLE BEC 107. (Continued) Current ratings for 6350/11000 volts grade PILC/SWA/PVC cable to BS6480/69

6 ELECTRICAL PARAMETERS

UGVCL/SP/591/11KV HT AB CABLE

Series 8146/5-V37 and Series 8150/5-V37

Section kv Power Cables

Cable flexibility Flexible. Chemical resistance Accidental

VDE Information. Degree of Pollution, Clearances and Creepage Distances and Insulating Materials

KNOW YOUR OPTIONS: 69 KV XLPE POWER CABLE

Medium Voltage Power Cables

4 IX D N E P P A Installation methods Current-carrying capacity and voltage drop for cables Reference method IET Wiring Matters

Airdac CNE and SNE, 600/1000V, Polyethylene Sheath, SANS 1507, NRS 063 & NRS 017

FIRE RESISTANT CABLE CONSTRUCTION OF CABLES

BRÖCKSKES D-VIERSEN PV1-F 4,0 mm BRÖCKSKES D-VIERSEN PV1-F 4,0 mm d d 2 2 C VDE-REG.-Nr /2009

THE PATHWAY TO POWER HIGH-VOLTAGE CABLES

HINDUSTAN PETROLEUM CORPORATION LIMITED ENGINEERING & PROJECTS GRESHAM ASSURANCE HOUSE, 2 ND FLOOR, A-1595(3) 1-A, SIR P M ROAD, FORT MUMBAI

Fire Resistant Cables

Flygt flexible cables

INTERNATIONAL STANDARD

e-mobility Special cables for electric vehicles Coroplast Fritz Müller GmbH & Co. KG Tapes Cables Cable Assemblies

Network Standard Advice No. 1420C 9/6/2011

RADOX railway cables acc. to EN and EN Edition 2009

PROFIBUS cable. PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications

Building Cables and Wires

Communication, Signal & Data Cables

PVC YALITIMLI SÝNYAL VE KONTROL KABLOLARI PVC INSULATED SIGNAL AND CONTROL CABLES (VDE 0812-VDE 0814-VDE 0245)

SCHEDULE ' A' TECHNICAL SPECIFICATION FOR 11/22/33KV H.T.XLPE POWER CABLE FOR DISTRIBUTION NETWORK IN MAHARASHTRA (SPECIFICATION NO.

Global cable expertise for rolling stock

XLPE Land Cable Systems User s Guide. Rev 5

ScottishPower Distribution Cables & Equipment. Metal Theft

XLPE рower cables. 2 Modern solutions for power cables I Estralin HVC

EDS KV TRIPLEX CABLE

< SD 200 C TP Continuously flexible TPE/PUR paired data cable with coloured cores and overall copper screen... 10

LEAD FREE FIREX. Interlock Armored Cables TECK90 and MC Industrial Cables. w w w. n e x a n s e n e r g y. c o m

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Allweather and Rubber Cables

BETAtrans. Cables and Systems for Rolling Stock. Edition 2006

Temperature Permissible ambient temperature. Weather Resistance to severe weather conditions. Impacts Cable mechanical resistance to impacts

TECHNICAL SPECIFICATION OF 11 / 22 KV XLPE POWER CABLE FOR SUB-STATION

HARAX circular connector

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.:

PVC Insulated Mains Cable

Fibre optic cables MDIC LSZH

Cables, Cable Laying & Accessories Manual

VOLTS - Copper conductor PVC insulated SSA 1320, IEC & BS 6004 HO 7V - U With Solid Conductor - TYPE IEC 01. Insulation Thickness

International Electrotechnical Commission Standards

High-ohmic/high-voltage resistors

TECHNICAL SPECIFICATION

HARTING Ethernet Cabling 4-poles Overview

3.6/6 kv XLPE insulated cables 5. 6/10 kv XLPE insulated cables /15 kv XLPE insulated cables /20 kv XLPE insulated cables 35

CAVEL VS80205 MADE IN ITALY 1000 V

ETHERLINE Ethernet Cable, Connectors & Tools

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

FIRE RESISTANT CABLES FP200 GOLD

Corporate Profile ROYAL. MODERN ROYAL ELECTRIC Ideal Power Solution MRE ELECTRICAL, INSTRUMENTATION & COMMUNICATION SYSTEMS

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Standard Buccaneer - Ethernet

PTC-Resistor Temperature-Sensors MINIKA to DIN and DIN

5.2. Overview. The better method to install solderless compression connectors on power cable

Removal of EP SP High Voltage Cable

COAX Cables Radio Frequency Cables

MICROCABLES. A complete vision of your connectivity needs. Catalogue

High Ohmic/High Voltage Metal Glaze Leaded Resistors

High-ohmic/high-voltage resistors

2 Wire Electronic Time Delay Switch. 2 Wire Slave Switch. 3 Wire Electronic Time Delay Switch

Vario-Series Accessories

AFUMEX LSX LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 BASEC APPROVED PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:

The Contractor shall furnish and install all shielded power cable suitable for use on this project.

Flexible and safe solutions, for decades. Cables for alarmand safety systems

Specializing in the cable business for over 38 years, PT. SUPREME CABLE

BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview

INTERNATIONAL STANDARD

01. HARTING RJ INDUSTRIAL RJ45 ETHERNET CONNECTORS

LOW VOLTAGE POWER CABLES

Transcription:

PVC insulated and PVC sheathed power and control cable with concentric copper conductor CONSTRUCTION Conductors: annealed copper solid class 1(RE), circular or circular compacted stranded conductor class 2 (RM) or stranded sector shaped conductor class 2 (SM) acc. to EN 60228 Insulation: special PVC compound type DIV4 acc. to HD 603.1 Inner covering: filling compound Concentric conductor: round copper wires and copper tape Sheath: special PVC compound type DMV5 acc. to HD 603.1 CHARACTERISTIC Colour of sheath: black Core identification: 1-core: 2-core: 3-core: 4-core: 5-core: 7 and more: black blue, brown brown, black, grey blue, brown, black, grey blue, brown, black, grey, black black with white numbering operating temperature: +70 o C Lowest ambient temperature for fixed installation: -30 o C Lowest installation temperature: -5 o C Maximum short-circuit conductor temperature: + 160 o C Minimum bending radius: 15 x D single core cables, 12 x D multicore cables, D overall Max. permissible tensile stress with cable grip for Cu-conductor: 50 N/mm 2 Test voltage: 4kV Current of short-circuit (1 sec): 115 x nominal cross section conductor (A) Flame retardant: IEC 60332-1-2 APPLICATIONS PVC insulated and sheathed power and auxiliary control cables for the supply of electrical energy. Special for installations in the open air, in underground and water, indoors, in cable ducts. The concentric conductor is allowed to use as neutral, protective or earthed conductor. Simultaneously, this also is permitted to apply as a screen for example earth-connected protection against contact. Standard length cable packing 500 or 1000m on drums. Other forms of packing and delivery are available on request

APPROVALS VDE, SIQ, GOST 1x6RE/6 10,1 198 3,08/3,08 1x10RE/10 11,0 279 1,83/1,83 2x1,5RE/1,5 11,7 194 12,1/12,1 2x1,5RM/1,5 12,1 205 12,1/12,1 2x2,5RE/2,5 12,5 237 7,41/7,41 2x2,5RM/2,5 13,0 252 7,41/7,41 2x4RE/4 14,6 334 4,61/4,61 2x4RM/4 15,2 356 4,61/4,61 2x6RE/6 15,9 416 3,08/3,08 2x6RM/6 16,2 429 3,08/3,08 2x10RE/10 17,6 571 1,83/1,83 2x10RM/10 18,2 596 1,83/1,83 2x16RE/16 19,9 794 1,15/1,15 2x16RM/16 20,7 833 1,15/1,15 2x25RM/16 24,5 1167 0,727/1,15 2x35RM/16 26,6 1434 0,524/1,15 3x1,5RE/1,5 12,1 215 12,1/12,1 3x1,5RM/1,5 12,6 228 12,1/12,1 3x2,5RE/2,5 13,0 267 7,41/7,41 3x2,5RM/2,5 13,5 283 7,41/7,41 3x4RE/4 15,2 379 4,61/4,61 3x4RM/4 15,9 403 4,61/4,61 3x6RE/6 16,6 479 3,08/3,08 3x6RM/6 17,0 494 3,08/3,08 3x10RE/10 18,4 669 1,83/1,83 3x10RM/10 19,0 695 1,83/1,83 3x16RE/16 20,8 940 1,15/1,15 3x16RM/16 21,7 983 1,15/1,15 3x25RM/16 25,8 1400 0,727/1,15 3x25RM/25 25,7 1480 0,727/0,727 3x35RM/16 28,0 1750 0,524/1,15 3x35RM/35 28,3 1927 0,524/0,524 3x35SM/16 25,5 1550 0,524/1,15 3x35SM/35 25,8 1727 0,524/0,524

3x50SM/25 28,4 2074 0,387/0,727 3x50SM/50 28,8 2279 0,387/0,387 3x70SM/35 32,5 2876 0,268/0,524 3x70SM/70 32,9 3180 0,268/0,268 3x95SM/50 36,6 3880 0,193/0,387 3x95SM/95 37,0 4309 0,193/0,193 3x120SM70 39,7 4849 0,153/0,268 3x120SM/120 39,7 5312 0,153/0,153 3x150SM/70 44,1 5850 0,124/0,268 3x150SM/150 44,7 6676 0,124/0,124 3x185SM/95 48,2 7311 0,0991/0,193 3x240SM/120 54,0 9478 0,0754/0,153 4x1,5RE/1,5 12,9 251 12,1/12,1 4x1,5RM/1,5 13,3 264 12,1/12,1 4x2,5RE/2,5 13,8 307 7,41/7,41 4x2,5RM/2,5 14,4 325 7,41/7,41 4x4RE/4 16,3 440 4,61/4,61 4x4RM/4 17,0 467 4,61/4,61 4x6RE/6 17,7 558 3,08/3,08 4x6RM/6 18,2 576 3,08/3,08 4x10RE/10 19,7 788 1,83/1,83 4x10RM/10 20,5 820 1,83/1,83 4x16RE/16 22,4 1116 1,15/1,15 4x16RM/16 23,4 1166 1,15/1,15 4x25RM/16 27,9 1683 0,727/1,15 4x25RM/25* 27,8 1763 0,727/0,727 4x35RM/16 30,5 2144 0,524/1,15 4x35RM/35* 30,8 2321 0,524/0,524 4x35SM/16 28,2 1951 0,524/1,15 4x35SM/35* 28,7 2142 0,524/0,524 4x50SM/25 32,2 2668 0,387/0,727 4x70SM/35 36,2 3641 0,268/0,524 4x95SM/50 41,1 4936 0,193/0,387 4x120SM/70 45,3 6202 0,153/0,268 4x150SM/70 49,5 7456 0,124/0,268 4x185SM/95 54,4 9328 0,0991/0,193 * based on norm

5x1,5RE/1,5 13,7 287 12,1/12,1 5x1,5RM/1,5 14,2 303 12,1/12,1 5x2,5RE/2,5 14,7 355 7,41/7,41 5x2,5RM/2,5 15,4 378 7,41/7,41 5x4RE/4 17,4 513 4,61/4,61 5x4RM/4 18,2 546 4,61/4,61 5x6RE/6 19,0 655 3,08/3,08 5x6RM/6 19,5 677 3,08/3,08 5x10RE/10 21,3 932 1,83/1,83 5x10RM/10 22,1 970 1,83/1,83 5x16RE/16 24,2 1323 1,15/1,15 5x16RM/16 25,3 1385 1,15/1,15 6x1,5RE/2,5 14,5 324 12,1/7,41 6x2,5RE/2,5 15,6 403 7,41/7,41 6x4RE/4 18,6 588 4,61/4,61 6x6RE/6* 20,4 755 3,08/3,08 7x1,5RE/2,5 14,5 334 12,1/7,41 7x1,5RM/2,5 15,1 353 12,1/7,41 7x2,5RE/2,5 15,6 420 7,41/7,41 7x2,5RM/2,5 16,4 448 7,41/7,41 7x4RE/4 18,6 615 4,61/4,61 8x1,5RE/2,5 15,1 368 12,1/7,41 8x2,5RE/4 16,7 489 7,41/4,61 8x4RE/6 19,8 708 4,61/3,08 10x1,5RE/2,5 17,2 442 12,1/7,41 10x2,5RE/4 19,2 589 7,41/4,61 10x4RE/6 22,6 853 4,61/3,08 12x1,5RE/2,5 17,7 485 12,1/7,41 12x2,5RE/4 19,6 648 7,41/4,61 12x4RE/6 23,2 948 4,61/3,08 14x1,5RE/2,5 18,4 534 12,1/7,41 14x2,5RE/6 20,8 738 7,41/3,08 14x4RE/6 24,3 1057 4,61/3,08 * based on norm

16x1,5RE/4 19,6 610 12,1/4,61 16x2,5RE/6 21,7 815 7,41/3,08 16x4RE/4* 25,3 1166 4,61/4,61 16x4RE/10 25,8 1217 4,41/1,83 19x1,5RE/4 20,4 676 12,1/4,61 19x2,5RE/6 22,6 911 7,41/3,08 19x4RE/10 27,0 1366 4,61/1,83 20x2,5RE/10 23,6 1020 7,41/1,83 21x1,5RE/6 21,3 750 12,1/3,08 21x2,5RE/10 23,4 1024 7,41/1,83 24x1,5RE/6 23,2 841 12,1/3,08 24x2,5RE/10 25,8 1151 7,41/1,83 27x1,5RE/6 23,6 903 12,1/3,08 30x1,5RE/6 24,3 972 12,1/3,08 30x2,5RE/10 27,1 1341 7,41/1,83 37x1,5RE/10 26,3 1173 12,1/1,83 40x1,5RE/10 27,0 1249 12,1/1,83 40x2,5RE/10 29,9 1695 7,41/1,83 48x1,5RE/16* 30,3 1472 12,1/1,15 61x1,5RE/16* 33,0 1797 12,1/1,15 * based on norm

Current ratings* Operating temperature at conductor 70 o C; ambient air temperature 30 o C, ground temperature 20 o C Installation Number of loaded cores Cross-section, mm 2 3 3 3 3 laying in ground Current ratings in Ampere (A) laying in air 1,5 27 31 19,5 22 2,5 36 40 26 29 4 47 51 34 39 6 59 63 44 49 10 79 84 60 67 16 102 108 80 89 25 133 139 108 119 35 160 166 132 146 50 190 196 160 177 70 234 238 202 221 95 280 281 249 270 120 319 315 289 310 150 357 347 329 350 185 402 385 377 399 240 463 432 443 462 Current ratings for control cables HD 627 S1 Number of loaded cores Cross-section, mm 2 3 laying in ground Current ratings in Ampere (A) 3 3 laying in air 1,5 27 19,5 2,5 36 26 4 47 34

The values are referred to the following basic conditions: Laying in ground Laying in air Ground temperature at installation depth: 20 o C Ambient temperature: 30 o C Load factor: 0,7 Load factor: 1,0 Soil-thermal resistivity of moist area: 1,0 k m/w Arrangement: free in air, protection against direct solar Soil-thermal resistivity of dry area: 2,5 k m/w radiation, no external heat sources, unrestricted Laying depth: 0,7 m dissipation of heat. Correction factors for various ambient air temperatures Ambient temperature, C 10 15 20 25 30 35 40 45 50 Rating factor 1,22 1,17 1,12 1,06 1,00 0,94 0,87 0,79 0,71 Conversion factors for multicore cable ( 5 cores) The conversion factors are to be used for laying the cables in ground or in air, to the values given in above tables Number of loaded cores Laying in ground Laying in air 5 0,70 0,75 7 0,60 0,65 10 0,50 0,55 14 0,45 0,50 19 0,40 0,45 24 0,35 0,40 40 0,30 0,35 61 0,25 0,30 Note: valid for cross-section 1,5 to 10 mm 2 * As defined in, HD 603 S1, HD 627 S1. Conversion factors for deviating ambient temperature defined in DIN VDE 0298 part 4. All the information contained in this document - including tables and diagrams - is given in good faith and believed to be correct at the time of publication. The information does not constitute a warranty nor representation for which TELE-FONIKA Kable assumes legal responsibility. TELE-FONIKA Kable reserves rights to introduce changes to the document at any time.