Quality Reliability Innovation. ISO 9001 : 2000 CERTIFIED BY AFAQ No. QUAL / 1997 / 7034 a COPPER TELECOMMUNICATION CABLES



Similar documents
MEDIUM VOLTAGE CABLES Up to and including 36 KV

Outside Telephone Cable

OPTICAL FIBER CABLES

Gulf Cable & Electrical Ind. Co.

T A B L E T 1 T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A

Specializing in the cable business for over 38 years, PT. SUPREME CABLE

Communication, Signal & Data Cables

TECHNICAL SPECIFICATION FOR LOW-FREQUENCY CABLES AND WIRES WITH PVC INSULATION AND PVC SHEATH

PROFIBUS cable. for PROFIBUS-PA and -DP 10/ EN

PROFIBUS cable. PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications

UGVCL/SP/591/11KV HT AB CABLE

Gulf Cable & Electrical Ind. Co.

ScottishPower Distribution Cables & Equipment. Metal Theft

We specialize in low voltage cables including: Stranded Single Cable H07V-R Flexible Single Cable H05V-K

3.6/6 kv XLPE insulated cables 5. 6/10 kv XLPE insulated cables /15 kv XLPE insulated cables /20 kv XLPE insulated cables 35

VOLTS - Copper conductor PVC insulated SSA 1320, IEC & BS 6004 HO 7V - U With Solid Conductor - TYPE IEC 01. Insulation Thickness

Corporate Profile ROYAL. MODERN ROYAL ELECTRIC Ideal Power Solution MRE ELECTRICAL, INSTRUMENTATION & COMMUNICATION SYSTEMS

COAX Cables Radio Frequency Cables

CONFLEX ELECTRIC CABLE

Global cable expertise for rolling stock

Fire Resistant Cables

Fibre optic cables MDIC LSZH

RF & Microwave cable assemblies C291

Airdac CNE and SNE, 600/1000V, Polyethylene Sheath, SANS 1507, NRS 063 & NRS 017

INTERNATIONAL STANDARD

MICROCABLES. A complete vision of your connectivity needs. Catalogue

HINDUSTAN PETROLEUM CORPORATION LIMITED ENGINEERING & PROJECTS GRESHAM ASSURANCE HOUSE, 2 ND FLOOR, A-1595(3) 1-A, SIR P M ROAD, FORT MUMBAI

GOWN. Central Loose Tube Cables Outdoor, Steel Wire Armor (SWA) A-DQ(ZN)2YB2Y Full Rodent Protection. Ordering Information.

144Fibre SM (G.652) Loose Tube Micro Lite Duct Optical Fibre Cable PRODUCT INFORMATION

Commercial Coaxial Cable

VIPERFLEX ELECTRIC CABLE

CAVEL VS80205 MADE IN ITALY 1000 V

APPLICATION ORIENTED DESIGN OF CABLES

RoHS DATA, COAXIAL AND ELECTRONIC M.R. D A TA, C O A X I A L, ECOLGICAL Telecom Cables A N D EL E CTRON I C. Cables

The Quality Connection. BETAflam Fire Resistant Safety Cables

GOSB. Central Loose Tube Cables Outdoor A-DQ(ZN)B2Y Standard Rodent Protection. Ordering Information. Applications. Features & Benefits

Cables, Cable Laying & Accessories Manual

Network Standard Advice No. 1420C 9/6/2011

CHAPTER VIII LINE PLANT SYSTEM COMMUNICATION THROUGH RE CABLE

Building Cables and Wires

Marine & Shipboard Cable JIS C 3410(1999) IEC , 353, 354, 376

APR 2016 Rev M

Fault location on power cables. Fault location on power cables

TFC/U-JIN Coaxial Cable Product Information Sheet Type: TU6T60-JVB

MV CABLE TYPE C

LEAD FREE FIREX. Interlock Armored Cables TECK90 and MC Industrial Cables. w w w. n e x a n s e n e r g y. c o m

Cable Guide. Cables, Connectors & Tools for installation of quality networks. TRIAX - your ultimate connection

INTERNATIONAL TELECOMMUNICATION UNION #/.3425#4)/. ).34!,,!4)/.!.$ 02/4%#4)/. /& #!",%3!.$ /4(%2 %,%-%.43 /& /543)$% 0,!.43

SCHEDULE ' A' TECHNICAL SPECIFICATION FOR 11/22/33KV H.T.XLPE POWER CABLE FOR DISTRIBUTION NETWORK IN MAHARASHTRA (SPECIFICATION NO.

GOSN. Central Loose Tube Cables Outdoor A-DQ(ZN)B2Y Standard Rodent Protection. Ordering Information. Applications. Features & Benefits

DATA SHEET SERVO LK SMS FX8PLUS SIGNAL

Coaxial cables? Video cables Loudspeaker cables

Chemical resistance Accidental

CORNING CABLE SYSTEMS GENERIC SPECIFICATION FOR TIGHT BUFFER OPTICAL FIBER CABLES FOR INTER- AND INTRABUILDING APPLICATIONS.

SECTION SIGNAL WIRE AND CABLE

Specification SFTP CAT6 Network Cable 23AWG CU

6 ELECTRICAL PARAMETERS

Trunk Cables.

The Quality Connection. Cable Solutions for Mobile Networks Business Unit Telecom

Fibre Optic Indoor/Outdoor Cable

TENDER: Tf{/ A

The color scheme for the fibers in the cable complies with the Telcordia (formerly Bellcore) specification.

MacArtney Underwater Cables - In stock

)454, !,5-).)5- #!",% 3(%!4(3 #/.3425#4)/. ).34!,,!4)/.!.$ 02/4%#4)/. /& #!",%3!.$ /4(%2 %,%-%.43 /& /543)$% 0,!.43. )454 Recommendation,

2 8 k V, 1 / C, T R X L P E I N S U L A T E D, F L A T S T R A P S H I E L D E D C A B L E, C O M P R E S S E D S T R A N D I N G

KNOW YOUR OPTIONS: 230 KV POWER CABLES

Flexible Control Cables

Temperature Permissible ambient temperature. Weather Resistance to severe weather conditions. Impacts Cable mechanical resistance to impacts

ETHERLINE Ethernet Cable, Connectors & Tools

KNOW YOUR OPTIONS: 69 KV XLPE POWER CABLE

High Voltage Systems. Today. The history of cables

Standard Buccaneer - Ethernet

CHARACTERISTICS AND ADVANTAGES OF OPTICAL FIBER CABLES

TECHNICAL SPECIFICATION

MEDIUM VOLTAGE POWER CABLES

Section kv Power Cables

The Quality Connection. Cables for Data Transmission in Industrial Automation

Flexible cables for submersible products

Flygt flexible cables

Catalogue Câbles d Energie

FIRE RESISTANT CABLE CONSTRUCTION OF CABLES

Flexible and safe solutions, for decades. Cables for alarmand safety systems

Broadcast and Commercial AV Cabling MASTER CATALOG

INTERNATIONAL STANDARD

Instrumentation Cable Power Cable Assembly Solutions...32

Standards Affecting a Premise T-1 Installation

OPTICAL FIBRE CABLES. for very-high bit transmission and FTTx networks

Important Information: Complete Terms and Conditions are printed on sales invoices

TABLE OF CONTENT

rue E. Delacroix / BP 1 F Draveil cedex FRANCE Tel : Fax : Issue 2 01/10/

Drop cables. Vorstadt 32 CH, 6304 Zug Switzerland.

RADOX railway cables acc. to EN and EN Edition 2009

The National Armored Cable Manufacturers Association Presents. Installation Standard for Types AC and MC Cables

Draka Industrial Cable GmbH

Gexol. Gexol. The Global Cable Solutions Company. Designed for safe, reliable performance in the harshest oil and gas operating environments

with coloured cores and overall copper screen UL/CSA... 17

Festoon 715 P PUR cable for flexible application in festoon systems

Offshore Transformer Platform. Technical Standard. Energinet.dk. HV, MV, LV and Signal Cables and Cable Routing

The Contractor shall furnish and install all shielded power cable suitable for use on this project.

IEEE POWER ENGINEERING SOCIETY CHICAGO CHAPTER THE OKONITE COMPANY WEDNESDAY JANUARY 11, 2006 JIM FITZGERALD ENGINEERING LINGO

Transcription:

Quality Reliability Innovation ISO : CERTIFIED BY AFAQ No. QUAL / 7 / 7 a COPPER TELECOMMUNICATION CABLES

COPPER TELECOMMUNICATION CABLES

CONTENTS 7 NOTICE INTRODUCTION QUALITY ASSURANCE RECOMMENDED ORDERING PARAMETERS OUR TYPE AND CODE DESIGNATION DUCT, UNDERGROUND NETWORK CABLES USED IN FEEDER AND DISTRIBUTION. - PE insulated, Petroleum jelly filled, PE sheathed. - PE insulated, PE sheathed DIRECT BURIAL, UNDERGROUND NETWORK CABLES USED IN FEEDER AND DISTRIBUTION 7. - PE insulated, Petroleum jelly filled, double steel tape armoured, PE sheathed 7. - PE insulated, double steel tape armoured, PE sheathed FIGURE AERIAL NETWORK CABLES USED IN DISTRIBUTION. - PE insulated, Petroleum jelly filled, PE sheathed, with steel messenger. - PE insulated, PE sheathed, with steel messenger. - PE insulated, Petroleum jelly filled, double steel tape armoured, PE sheathed, with steel messenger. - PE insulated, double steel tape armoured, PE sheathed, with steel messenger INDOOR USE TELEPHONE CABLES, PVC INSULATED AND PVC SHEATHED JUMPER WIRE DROP WIRE ANNEX A - INDENTIFICATION OF CONDUCTORS AND UNITS AND CABLE CORE CONSTRUCTION OF UNDERGROUND AND AERIAL NETWORK CABLES ANNEX B - IDENTIFICATION OF CONDUCTORS OF INDOOR USE TELEPHONE CABLE - LIBTEL P a g e 7

NOTICE As this catalogue is not intended to cover all of LIBAN CABLES S A L possibilities in Copper Telephone Cables manufacturing, the hereafter listing of the types of cables is not restrictive but only indicative of the main and most current types we manufacture. On the other hand, our specification sheets are inspired mainly from International Electrotechnical Commission Specifications (IEC) only in order to conform with the sustained trend, noticed both regionally and worldwide, towards these same IEC supposed to inspire any further standardization approaches. That is why, while consulting this brochure, it is important to keep in mind that: - any combination or change of the constructional details mentioned in hereafter chapter remains feasible, on base of special conception development, matching any special or different specifications, - we can offer additional possibilities and alternatives like for example: - Pair, quad, and other basic formations - Unit or concentric stranding - Comparted construction (ex: MIC cables) - our production encompasses all telecom cables of low, high or special mutual capacitance and conductor gauges mm. F i n a l l y, and within our policy of constant improvement, we reserve the right to alter any part of the information contained in this publication without incurring any obligation. In all cases this brochure being only indicatve, and unless expressly agreed upon, it cannot be considered by any mean as contractual document.

INTRODUCTION Devoted to the manufacturing of electric and telecom cables, Liban Cables is the first and largest supplier in Lebanon and a leader in the Middle-East region. Liban Cables was founded in 7 by a group of Lebanese industrialists backed up by the technical assistance of two international leading firms : - Les Cables de Lyon - France (became A L C AT E Lafterwards and NEXANS by end ) - Phelps Dodge - U.S.A. S t a ffed with qualified engineers and highly skilled technicians, our plant is located in Nahr-Ibrahim at Km from Beirut, where cables are designed and manufactured according to all international specifications : IEC, VDE, UTE, BS and others on customer request. Early after its foundation, Liban Cables has become the major supplier of the Lebanese market in both the public and private sectors. The product range of Liban Cables covers all Copper and Aluminium electric cables, as well as copper and fiber optic communication cables, in addition to a wide variety of special cables manufactured on customer request. High quality cables, continuous developments of the production range, direct and fast shipments have contributed in rendering Liban Cables an important exporter for many countries on the three limitrophe continents (Asia, Europe, Africa). Liban Cables products are particularly appreciated by administrations and international contractors operating in the region and seeking reliable and direct supplies of power and communication cables.

QUALITY Step by step, from raw material to final product, quality constitutes a major concern to Liban Cables. Raw material are continuously and repetitively tested from trial orders till the last batch received afterwards. Products are tested within two simultaneous procedures : - A built in quality control system carried out by the production itself at any step of work in process. - A parallel and contradictory procedure is also carried out on the same stages and products by independent inspectors reporting to the quality control service. End users and/or third part inspection authorities are also constantly commissioning the finished products and assessing the strict conformity to ordered specifications. In fact, our ISO certification stated in Feb 7 by the International Certification Network (EQNET) is certified by the French Association for Quality Assurance (AFAQ), the well known rigourous and independant accredited European assessor. T h i s certification, which upgraded to ISO : on February, under reference A FAQ Nº QUAL / 7 / 7 a, confirms the soundness and the performance of the Quality System we apply for the Design, the Development, the Manufacturing and the Marketing & Sales of all our products. RECOMMENDED ORDERING PARAMETERS For prompt quotation / supplies, please make sure your inquiries and your orders are securing the following data : - International or Special Standard. (Alternatively, the precise usage of the cable.) - Constructional details (Materials, Pairs / Quads, Mutual Capacitance, Filling, Screens, Armour, Messenger...etc). - Other requirements - Packing & Tolerances - Required delivery time - Required validity

OUR TYPE AND CODE DESIGNATION The type designation is a combination of symbols (letters and numbers) indicating the type, and the main constructional elements of the cable as follows : OUTDOOR CABLES 7 No letter - PE sheath Y - PVC sheath U - Halogen free, Low smoke and fume sheath L - Lead sheath B - Black steel tape armouring G - Galvanized steel tape armouring R - Galvanized round steel wire armouring F - Flat steel wire armouring A- Aluminium tape armouring W - Round aluminium wire armouring Z - One side coated corrugated steel tape K - Two side coated corrugated steel tape S - One side coated aluminium screen D - Two side coated aluminium screen I - Two side coated corrugated aluminium screen Z - Non coated aluminium screen O - Copper tape screen H - Corrugated copper tape screen C - Copper wire screen Q - Lacquered aluminium screen T-Telephone cables P - Solid PE insulation C - Cellular PE insulation M - (Foam / skin) PE insulation Y - PVC insulation - For cables stranded in pairs - For cables stranded in star quads A- Aerial Cables U - Underground / Armoured Cables D - Underground / Duct Cables

Example: TUMDG - Telephone cable, underground, pair Type, foam / skin PE insulated, two side coated Aluminium screened, galvanized steel tape armoured. N. B. : The sequence of the rd and th characters indicates whether the cable is jelly filled or not. For jelly filled cables, these two characters are interchanged, i.e. the letter indicating the type of insulation (P,C,M or T) comes before the number indicating the type of stranding ( or ). Examples : TUMDG - Telephone cable, underground, foam / skin PE insulated, pair Type, jelly filled, two side coated Aluminium screened, galvanized steel tape armoured. TUMDG - Same cable but not jelly filled. INDOOR CABLES LIBTEL LIBTLV LIBTLS LIBTLA for unscreened PVC insulated and sheathed cables for tinned copper conductor, PVC insulated and sheathed cables for screened, PVC insulated and sheathed cables for armoured, PVC insulated and sheathed cables

DUCTUNDERGROUND NETWORK CABLE USED IN FEEDER AND DISTRIBUTION ( FILLED ). polyethylene insulated longitudinally watertight polyethylene sheathed Specification: Based on IEC 7- and 7- Type and Application Our type TDMD Pulling in duct CONSTRUCTION Conductors Solid annealed bare copper wire of: - -. or. mm nominal. Other wire s are also available. Insulation One layer of fully coloured solid polyethylene, or one layer of colourless cellular polyethylene covered by a thin layer of fully coloured solid polyethylene (foam-skin). Radial thickness determined to satisfy the electrical characteristics. Twisting conductors are twisted into a pair. D i fferent twisting laylengths are used to minimize crosstalk. Quad cables are available upon request. Stranding In sub-units of pairs, for units of or pairs and for cables of up to pairs. In units of or pairs for cables of more than pairs. Other repartition also available. Spare pairs Located within the units or between the units of the outer layer of the cable core, they are used to replace the pairs damaged during the manufacturing process. Cable core construction, identification of conductors and units: see annex A. Longitudinal watertightness The cable core interstices are filled with a suitable compound (petroleum jelly) to avoid longitudinal water penetration inside the cable. Cable core protection One or more tapes helically or longitudinally laid with an overlap. Continuity wire (when specified) One mm tinned copper wire is longitudinally laid to ensure the electrical continuity of the screen. Moisture barrierand screen One or two side ethylene copolymere coated smooth aluminium tape is longitudinally laid with an overlap. thickness of aluminium :. mm. D i fferent or corrugated screen also available. Sheath Black, high, medium or low density polyethylene. radial thickness: as requested or as per the physical characteristics table. Marking manufacturer s identification number of pairs and conductor sequentially numbered length marking at each meter interval (or as requested).

Usual electrical characteristics Loop resistance at ºC in direct current Diameter mm..... value Ω/km.. 7.. 7... Maximum individual value Ω/km... 7... Dielectric strength during mn in direct current* Between conductors: kv Between conductors and screen : kv * the test can be achieved under alternative current with half of above voltages. Insulation resistance under V minimum direct current Lowest value after mn minimum : MΩ.km. Mutual capacitance at Hz Maximum individual: nf/km. For cables of equal or more than pairs: maximum average: nf/km. cables of low level mutual capacitance ( nf/km) are also available Maximum capacitance unbalance at Hz in pf per meters length of cable. Individual value (pf) % values (pf), &. mm. mm, &. mm. mm Pair-to-pair Side-to-side Pair-to-earth 7 Side-to-earth 7 Maximum calculated attenuation at Hz and ºC ø mm.7 db/km ø mm. db/km ø. mm. db/km ø. mm. db/km 7

DUCT UNDERGROUND NETWORK CABLE USED IN FEEDER AND DISTRIBUTION Foam-skin Polyethylene insulated - Petroleum Jelly filled - Polyethylene sheathed (maximum average mutual capacitance nf/km) 7 7 7 7 7........................ 7 7 7 7 7 7 7 7 7 7......................... 7 77 7 7 7 7 7 7 7 7 7 7 7 77 7 7 7 7 77 7 7 7 7 7 number of pairs Conductor Usual number of spare pairs Usual nominal delivery length (m) Approx. cable core sheath thickness Approx. nominal outer lineic weight (Kg/Km) * Other conductor gauges, mutual capacitances, different pair count cables and different delivery lengths are also available

DUCTUNDERGROUND NETWORK CABLE USED IN FEEDER AND DISTRIBUTION ( AIRCORE ). polyethylene insulated polyethylene sheathed Specification: Based on IEC 7- and 7- Type and Application Our type TDPD Pulling in duct CONSTRUCTION Conductors Solid annealed bare copper wire of: - -. or. mm nominal. Other wire s are also available. Insulation Fully coloured s o l i d (or foam skin when specified) polyethylene. Radial thickness determined to satisfy the electrical characteristics. Twisting conductors are twisted into a pair. D i fferent twisting laylengths are used to minimize crosstalk. Quad cables are available upon request. Stranding In sub-units of pairs, for units of or pairs and for cables of up to pairs. In units of or pairs for cables of more than pairs. Other repartition also available. Spare pairs Located within the units or between the units of the outer layer of the cable core, they are used to replace the pairs damaged during the manufacturing process. Cable core construction, identification of conductors and units: see annex A. Cable core protection One or more tapes helically or longitudinally laid with an overlap. Continuity wire (when specified) One mm tinned copper wire is longitudinally laid to ensure the electrical continuity of the screen. Moisture barrierand screen One or two side ethylene copolymere coated smooth aluminium tape is longitudinally laid with an overlap. thickness of aluminium :. mm. D i fferent or corrugated screen also available. Sheath Black, high, medium or low density polyethylene. radial thickness: as requested or as per the physical characteristics table. Marking manufacturer s identification number of pairs and conductor sequentially numbered length marking at each meter interval (or as requested).

Usual electrical characteristics Loop resistance at ºC in direct current Diameter mm..... value Ω/km.. 7.. 7... Maximum individual value Ω/km... 7... Dielectric strength during mn in direct current* Between conductors: kv Between conductors and screen : kv * the test can be achieved under alternative current with half of above voltages. Insulation resistance under V minimum direct current Lowest value after mn minimum : MΩ.km. Mutual capacitance at Hz Maximum individual: nf/km. For cables of equal or more than pairs: maximum average: nf/km. cables of low level mutual capacitance ( nf/km) are also available Maximum capacitance unbalance at Hz in pf per meters length of cable. Individual value (pf) % values (pf), &. mm. mm, &. mm. mm Pair-to-pair Side-to-side Pair-to-earth 7 Side-to-earth 7 Maximum calculated attenuation at Hz and ºC ø mm.7 db/km ø mm. db/km ø. mm. db/km ø. mm. db/km

number of pairs 7 7 7 7 7 Conductor............................ DUCT UNDERGROUND NETWORK CABLE USED IN FEEDER AND DISTRIBUTION Solid PE insulated - PE sheathed (maximum average mutual capacitance nf/km) Usual number of spare pairs Approx. cable core 7 7 7 7 7 7 7 7 7 7 7 7 sheath thickness............................ Approx. nominal outer 7 7 7 7 7 7 7 7 7 7 7 7 lineic weight (Kg/Km) * Other conductor gauges, mutual capacitances, different pair count cables and different delivery lengths are also available 7 7 7 7 7 7 777 7 7 7 7 77 7 7 7 7 7 7 7 7 7 77 Usual nominal delivery length (m)

7 DIRECT BURIALUNDERGROUND NETWORK CABLE USED IN FEEDER AND DISTRIBUTION ( FILLED ) 7. polyethylene insulated longitudinally watertight double steel tape armoured polyethylene sheathed CONSTRUCTION Conductors Solid annealed bare copper wire of: - -. or. mm nominal. Other wire s are also available. Insulation One layer of fully coloured s o l i d polyethylene or one layer of colourless c e l l u l a r polyethylene covered by a thin layer of fully coloured solid polyethylene (foam-skin). Radial thickness determined to satisfy the electrical characteristics. Twisting conductors are twisted into a pair. D i fferent twisting laylengths are used to minimize crosstalk. Quad cables are available upon request. Stranding In sub-units of pairs, for units of or pairs and for cables of up to pairs. In units of or pairs for cables of more than pairs. Other repartition also available. Spare pairs Located within the units or between the units of the outer layer of the cable core, they are used to replace the pairs damaged during the manufacturing process. Cable core construction, identification of conductors and units: see annex A. Longitudinal watertightness The cable core interstices are filled with a suitable compound (petroleum jelly) to avoid longitudinal water penetration inside the cable. Cable core protection One or more tapes helically or longitudinally laid with an overlap. Continuity wire (when specified) One mm tinned copper wire is longitudinally laid to ensure the electrical continuity of the screen. Moisture barrierand screen One or two side ethylene copolymere coated smooth aluminium tape is longitudinally laid with an overlap. Specification: Based on IEC 7- and 7- Type and Application Our type TUΜDG Directly buried thickness of aluminium :. mm. D i fferent or corrugated screen also available. Innersheath Colourless or black high (or low when specified) density polyethylene. radial thickness: as requested or as per the physical characteristics table. Armour Double steel tape helically laid on a crepe paper bedding (facultative). The nominal thickness of each tape is. mm or mm (see the physical characteristics table). Outersheath Black low density polyethylene. radial thickness: as requested or as per the physical characteristics table. Marking manufacturer s identification number of pairs and conductor sequentially numbered length marking at each meter interval (or as requested).

Usual electrical characteristics Loop resistance at ºC in direct current Diameter mm..... value Ω/km.. 7.. 7... Maximum individual value Ω/km... 7... Dielectric strength during mn in direct current* Between conductors: kv Between conductors and screen : kv * the test can be achieved under alternative current with half of above voltages. Insulation resistance under V minimum direct current Lowest value after mn minimum : MΩ.km. Mutual capacitance at Hz Maximum individual: nf/km. For cables of equal or more than pairs: maximum average: nf/km. cables of low level mutual capacitance ( nf/km) are also available Maximum capacitance unbalance at Hz in pf per meters length of cable. Individual value (pf) % values (pf), &. mm. mm, &. mm. mm Pair-to-pair Side-to-side Pair-to-earth 7 Side-to-earth 7 Maximum calculated attenuation at Hz and ºC ø mm.7 db/km ø mm. db/km ø. mm. db/km ø. mm. db/km

7 7 7 7 DIRECT BURIAL UNDERGROUND NETWORK CABLE USED IN FEEDER AND DISTRIBUTION Foam-skin Polyethylene insulated - Petroleum Jelly filled Double steel tape armoured - Polyethylene sheathed (maximum average mutual capacitance nf/km) Number of pairs........................ 7 7 7 7 7 7...................................................................... 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 Conductor Usual number of spare pairs Steel tape thickness Approx. nominal outer Usual nominal delivery length (m) lineic weight (Kg/Km) sheath thickness Approx. cable core inner outer * Other conductor gauges, mutual capacitances, different pair count cables and different delivery lengths are also available

7 DIRECTBURIALUNDERGROUND NETWORK CABLE USED IN FEEDER AND DISTRIBUTION ( AIRCORE ) 7. polyethylene insulated double steel tape armoured polyethylene sheathed Specification: Based on IEC 7- and 7- Type and Application Our type TUPDG Directly buried CONSTRUCTION Conductors Solid annealed bare copper wire of: - -. or. mm nominal. Other wire s are also available. Insulation Fully coloured solid (or foam skin when specified) polyethylene. Radial thickness determined to satisfy the electrical characteristics. Twisting conductors are twisted into a pair. D i fferent twisting laylengths are used to minimize crosstalk. Quad cables are available upon request. Stranding In sub-units of pairs, for units of or pairs and for cables of up to pairs. In units of or pairs for cables of more than pairs. Other repartition also available. Spare pairs Located within the units or between the units of the outer layer of the cable core, they are used to replace the pairs damaged during the manufacturing process. Cable core construction, identification of conductors and units: see annex A. Cable core protection One or more tapes helically or longitudinally laid with an overlap. Continuity wire (when specified) One mm tinned copper wire is longitudinally laid to ensure the electrical continuity of the screen. Moisture barrierand screen One or two side ethylene copolymere coated smooth aluminium tape is longitudinally laid with an overlap. thickness of aluminium :. mm. Different or corrugated screen also available. Inner sheath Colourless or black high (or low when specified) density polyethylene. radial thickness: as requested or as per the physical characteristics table. Armour Double steel tape helically laid on a crepe paper bedding (facultative). The nominal thickness of each tape is. mm or mm (see the physical characteristics table). Outer sheath Black low density polyethylene. radial thickness: as requested or as per the physical characteristics table. Marking manufacturer s identification number of pairs and conductor sequentially numbered length marking at each meter interval (or as requested).

Usual electrical characteristics Loop resistance at ºC in direct current Diameter mm..... value Ω/km.. 7.. 7... Maximum individual value Ω/km... 7... Dielectric strength during mn in direct current* Between conductors: kv Between conductors and screen : kv * the test can be achieved under alternative current with half of above voltages. Insulation resistance under V minimum direct current Lowest value after mn minimum : MΩ.km. Mutual capacitance at Hz Maximum individual: nf/km. For cables of equal or more than pairs: maximum average: nf/km. cables of low level mutual capacitance ( nf/km) are also available Maximum capacitance unbalance at Hz in pf per meters length of cable. Individual value (pf) % values (pf), &. mm. mm, &. mm. mm Pair-to-pair Side-to-side Pair-to-earth 7 Side-to-earth 7 Maximum calculated attenuation at Hz and ºC ø mm.7 db/km ø mm. db/km ø. mm. db/km ø. mm. db/km

7 7 7 7 7 DIRECT BURIAL UNDERGROUND NETWORK CABLE USED IN FEEDER AND DISTRIBUTION Solid Polyethylene insulated - Double steel tape armoured - Polyethylene sheathed (maximum average mutual capacitance nf/km) Number of pairs........................ 7 7 7 7 7 7 7 7.................................................................. 7 7 7 7 7 7 7 7 7 7 77 7 77 7 7 77 7 7 7 7 7 7 7 7 Conductor Usual number of spare pairs Steel tape thickness Approx. nominal outer Usual nominal delivery length (m) lineic weight (Kg/Km) sheath thickness Approx. cable core inner outer * Other conductor gauges, mutual capacitances, different pair count cables and different delivery lengths are also available

AERIALNETWORK CABLE USED IN DISTRIBUTION ( FILLED ). polyethylene insulated longitudinally watertight polyethylene sheathed steel messenger CONSTRUCTION Conductors Solid annealed bare copper wire of: - -. or. mm nominal. Other wire s are also available. Insulation One layer of fully coloured s o l i d polyethylene or one layer of colourless c e l l u l a r polyethylene covered by a thin layer of fully coloured s o l i d polyethylene (foam-skin). Radial thickness determined to satisfy the electrical characteristics. Twisting conductors are twisted into a pair. D i fferent twisting laylengths are used to minimize crosstalk. Quad cables are available upon request. Stranding In sub-units of pairs, for units of or pairs and for cables of up to pairs. In units of or pairs for cables of more than pairs. Other repartition also available. Spare pairs Located within the units or between the units of the outer layer of the cable core, they are used to replace the pairs damaged during the manufacturing process. Cable core construction, identification of conductors and units: see annex A. Longitudinal watertightness The cable core interstices are filled with a suitable compound (petroleum jelly) to avoid longitudinal water penetration inside the cable. Cable core protection One or more tapes helically or longitudinally laid with an overlap. Continuity wire (when specified) One mm tinned copper wire is longitudinally laid to ensure the electrical continuity of the screen. Moisture barrierand screen One or two side ethylene copolymere Specification: Based on IEC 7- and 7- Type and Application Our type TΑΜD Self- supported aerial laying coated smooth aluminium tape is longitudinally laid with an overlap. thickness of aluminium :. mm. Different or corrugated screen also available. Messenger One strand of galvanized steel wires. Diameter of wires, number of wires and minimum breaking strength : as requested or as per the physical characteristics table. Sheath Black, high, medium or low density, figure shaped polyethylene i n c l u d i n g the cable core and the messenger. radial thickness : as requested or as per the physical characteristics table. Marking manufacturer s identification number of pairs and conductor sequentially numbered length marking at each meter interval (or as required).

Usual electrical characteristics Loop resistance at ºC in direct current Diameter mm..... value Ω/km.. 7.. 7... Maximum individual value Ω/km... 7... Dielectric strength during mn in direct current* Between conductors: kv Between conductors and screen : kv * the test can be achieved under alternative current with half of above voltages. Insulation resistance under V minimum direct current Lowest value after mn minimum : MΩ.km. Mutual capacitance at Hz Maximum individual: nf/km. For cables of equal or more than pairs: maximum average: nf/km. cables of low level mutual capacitance ( nf/km) are also available Maximum capacitance unbalance at Hz in pf per meters length of cable. Individual value (pf) % values (pf), &. mm. mm, &. mm. mm Pair-to-pair Side-to-side Pair-to-earth 7 Side-to-earth 7 Maximum calculated attenuation at Hz and ºC ø mm.7 db/km ø mm. db/km ø. mm. db/km ø. mm. db/km

number of pairs 7 7 7 7 Conductor............... AERIAL NETWORK CABLE USED IN DISTRIBUTION Foam skin Polyethylene insulated - Petroleum jelly filled Polyethylene sheathed - Steel messenger (maximum average mutual capacitance nf/km) Usual number of spare pairs Approx. cable core 7 7 7 7 7 sheath thickness... Messenger Dim. Nbr.X dia. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. Mini. break load (dan) 7 7 7 7 Nom. outer dimension hght. X dia. X. X. X. X. X.7 X. X. X 7 X. X. X. X. X 7. X.7 X X X. X. X. X. X 7 X X 7 X X. X. X. X X X X * Other conductor gauges, mutual capacitances, different pair count cables and different delivery lengths are also available lineic weight (Kg/Km) 77 7 7 Usual nominal delivery length (m) Typical conditions of laying: Maximal distance between the supports (span): m. sag for a m span at ºC without overload:. m. security coefficient > in the following extreme climatic conditions: Hypothesis A: km/h wind speed (pressure: pa) at ºC. Hypothesis B: km/h wind speed (pressure: pa) - ºC without ice. security coefficient > in the following extreme climatic conditions: Hypothesis C: ice sleeve of mm thickness at - ºC without wind.

AERIALNETWORK CABLE USED IN DISTRIBUTION ( AIRCORE ). polyethylene insulated polyethylene sheathed steel messenger Specification: Based on IEC 7- and 7- Type and Application Our type TΑΜD Self- supported aerial laying CONSTRUCTION Conductors Solid annealed bare copper wire of: - -. or. mm nominal. Other wire s are also available. Insulation One layer of fully coloured s o l i d polyethylene or one layer of colourless c e l l u l a r polyethylene covered by a thin layer of fully coloured s o l i d polyethylene (foam-skin). Radial thickness determined to satisfy the electrical characteristics. Twisting conductors are twisted into a pair. D i fferent twisting laylengths are used to minimize crosstalk. Quad cables are available upon request. Stranding In sub-units of pairs, for units of or pairs and for cables of up to pairs. In units of or pairs for cables of more than pairs. Other repartition also available. Spare pairs Located within the units or between the units of the outer layer of the cable core, they are used to replace the pairs damaged during the manufacturing process. Cable core construction, identification of conductors and units: see annex A. Cable core protection One or more tapes helically or longitudinally laid with an overlap. Continuity wire (when specified) One mm tinned copper wire is longitudinally laid to ensure the electrical continuity of the screen. Moisture barrierand screen One or two side ethylene copolymere coated smooth aluminium tape is longitudinally laid with an overlap. thickness of aluminium :. mm. Different or corrugated screen also available. Messenger One strand of galvanized steel wires. Diameter of wires, number of wires and minimum breaking strength : as requested or as per the physical characteristics table. Sheath Black, high, medium or low density, figure shaped polyethylene including the cable core and the messenger. radial thickness : as requested or as per the physical characteristics table. Marking manufacturer s identification number of pairs and conductor sequentially numbered length marking at each meter interval (or as required).

Usual electrical characteristics Loop resistance at ºC in direct current Diameter mm..... value Ω/km.. 7.. 7... Maximum individual value Ω/km... 7... Dielectric strength during mn in direct current* Between conductors: kv Between conductors and screen : kv * the test can be achieved under alternative current with half of above voltages. Insulation resistance under V minimum direct current Lowest value after mn minimum : MΩ.km. Mutual capacitance at Hz Maximum individual: nf/km. For cables of equal or more than pairs: maximum average: nf/km. cables of low level mutual capacitance ( nf/km) are also available Maximum capacitance unbalance at Hz in pf per meters length of cable. Individual value (pf) % values (pf), &. mm. mm, &. mm. mm Pair-to-pair Side-to-side Pair-to-earth 7 Side-to-earth 7 Maximum calculated attenuation at Hz and ºC ø mm.7 db/km ø mm. db/km ø. mm. db/km ø. mm. db/km

number of pairs 7 7 7 7 AERIAL NETWORK CABLE USED IN DISTRIBUTION Foam skin Polyethylene insulated - Polyethylene sheathed - Steel messenger (maximum average mutual capacitance nf/km) Conductor............... Usual number of spare pairs Approx. cable core 7 7 7 sheath thickness. Messenger Dim. Nbr.X dia. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. Mini. break load (dan) 7 7 7 7 Nom. outer dimension hght. X dia. X. X. X.7 X. X. X.7 X. X 7 X. X. X.7 X. X. X. X X X. X. X. X. X. X X X X. X 7 X 7. X 7 X X X 7 * Other conductor gauges, mutual capacitances, different pair count cables and different delivery lengths are also available lineic weight (Kg/Km) 7 7 7 7 7 7 7 7 Usual nominal delivery length (m) Typical conditions of laying: Maximal distance between the supports (span): m. sag for a m span at ºC without overload:. m. security coefficient > in the following extreme climatic conditions: Hypothesis A : km/h wind speed (pressure: pa) at ºC. Hypothesis B : km/h wind speed (pressure: pa) - ºC without ice. security coefficient > in the following extreme climatic conditions: Hypothesis C : ice sleeve of mm thickness at - ºC without wind.

AERIALNETWORK CABLE USED IN DISTRIBUTION ( FILLED ). polyethylene insulated longitudinally watertight double steel tape armoured polyethylene sheathed steel messenger CONSTRUCTION Conductors Solid annealed bare copper wire of: - -. or. mm nominal. other wire s are also available. Insulation One layer of fully coloured s o l i d polyethylene or one layer of colourless c e l l u l a r polyethylene covered by a thin layer of fully coloured s o l i d polyethylene (foam-skin). Radial thickness determined to satisfy the electrical characteristics. Twisting conductors are twisted into a pair. D i fferent twisting laylengths are used to minimize crosstalk. Quad cables are available upon request. Stranding In sub-units of pairs, for units of or pairs and for cables of up to pairs. In units of or pairs for cables of more than pairs. Other repartition also available. Spare pairs Located within the units or between the units of the outer layer of the cable core, they are used to replace the pairs damaged during the manufacturing process. Cable core construction, identification of conductors and units: see annex A. Longitudinal watertightness The cable core interstices are filled with a suitable compound (petroleum jelly) to avoid longitudinal water penetration inside the cable. Cable core protection One or more tapes helically or longitudinally laid with an overlap. Continuity wire (when specified) One mm tinned copper wire is longitudinally laid to ensure the electrical continuity of the screen. Specification: Based on IEC 7- and 7- Type and Application Our type TΑΜDG Self- supported aerial laying Moisture barrierand screen One or two side ethylene copolymere coated smooth aluminium tape is longitudinally laid with an overlap. thickness of aluminium :. mm. Different or corrugated screen also available. Innersheath Colourless or black high (or low when specified) density polyethylene. radial thickness: as requested or as per the physical characteristics table. Armour Double steel tape helically laid on a crepe paper bedding (facultative). The nominal thickness of each tape is. mm or mm. Outer sheath Black low density polyethylene. radial thickness: as requested or as per the physical characteristics table. Marking manufacturer s identification number of pairs and conductor sequentially numbered length marking at each meter interval (or as required).

Usual electrical characteristics Loop resistance at ºC in direct current Diameter mm..... value Ω/km.. 7.. 7... Maximum individual value Ω/km... 7... Dielectric strength during mn in direct current* Between conductors: kv Between conductors and screen : kv * the test can be achieved under alternative current with half of above voltages. Insulation resistance under V minimum direct current Lowest value after mn minimum : MΩ.km. Mutual capacitance at Hz Maximum individual: nf/km. For cables of equal or more than pairs: maximum average: nf/km. cables of low level mutual capacitance ( nf/km) are also available Maximum capacitance unbalance at Hz in pf per meters length of cable Individual value (pf) % values (pf), &. mm. mm, &. mm. mm Pair-to-pair Side-to-side Pair-to-earth 7 Side-to-earth 7 Maximum calculated attenuation at Hz and ºC ø mm.7 db/km ø mm. db/km ø. mm. db/km ø. mm. db/km

AERIAL NETWORK CABLE USED IN DISTRIBUTION Foam skin Polyethylene insulated - Petroleum jelly filled - Double steel tape armoured Polyethylene sheathed - Steel messenger (maximum average mutual capacitance nf/km) number of pairs 7 7 7 7 Conductor............... Usual number of spare pairs Approx. cable core 7 7 7 7 sheath thickness Inner Outer... Messenger Dim. Nbr.X dia. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. Mini. break load (dan) Nom. outer dimension hght. X dia. X. X.7 X. X 7. X.7 X X X X. X. X. X. X X X X X.7 7 X 7. X. X 7 X 7 X 7 X X X 7. X X X X X X 7 * Other conductor gauges, mutual capacitances, different pair count cables and different delivery lengths are also available..... lineic weight (Kg/Km) 7 7 7 7 7 Usual nominal delivery length (m) Typical conditions of laying: Maximal distance between the supports (span): m. sag for a m span at ºC without overload:. m. security coefficient > in the following extreme climatic conditions: Hypothesis A : km/h wind speed (pressure: pa) at ºC. Hypothesis B : km/h wind speed (pressure: pa) - ºC without ice. security coefficient > in the following extreme climatic conditions: Hypothesis C : ice sleeve of mm thickness at - ºC without wind.

AERIALNETWORK CABLE USED IN DISTRIBUTION ( AIRCORE ). polyethylene insulated double steel tape armoured polyethylene sheathed steel messenger Specification: Based on IEC 7- and 7- Type and Application Our type TΑΜDG Self- supported aerial laying CONSTRUCTION Conductors Solid annealed bare copper wire of: - -. or. mm nominal. Insulation One layer of fully coloured s o l i d polyethylene or one layer of colourless c e l l u l a r polyethylene covered by a thin layer of fully coloured s o l i d polyethylene (foam-skin). Radial thickness determined to satisfy the electrical characteristics. Twisting conductors are twisted into a pair. D i fferent twisting laylengths are used to minimize crosstalk. Quad cables are available upon request. Stranding In sub-units of pairs, for units of or pairs and for cables of up to pairs. In units of or pairs for cables of more than pairs. Other repartition also available. Spare pairs Located within the units or between the units of the outer layer of the cable core, they are used to replace the pairs damaged during the manufacturing process. Cable core construction, identification of conductors and units: see annex A. Cable core protection One or more tapes helically or longitudinally laid with an overlap. Continuity wire (when specified) One mm tinned copper wire is longitudinally laid to ensure the electrical continuity of the screen. Moisture barrierand screen One or two side ethylene copolymere coated smooth aluminium tape is longitudinally laid with an overlap. thickness of aluminium :. mm. Different or corrugated screen also available. Inner sheath Colourless or black high (or low when specified) density polyethylene. radial thickness: as requested or as per the physical characteristics table. Armour Double steel tape helically laid on a crepe paper bedding (facultative). The nominal thickness of each tape is. mm or mm Outersheath Black low density polyethylene. radial thickness: as requested or as per the physical characteristics table. Marking manufacturer s identification number of pairs and conductor sequentially numbered length marking at each meter interval (or as required). 7

Usual electrical characteristics Loop resistance at ºC in direct current Diameter mm..... value Ω/km.. 7.. 7... Maximum individual value Ω/km... 7... Dielectric strength during mn in direct current* Between conductors: kv Between conductors and screen : kv * the test can be achieved under alternative current with half of above voltages. Insulation resistance under V minimum direct current Lowest value after mn minimum : MΩ.km. Mutual capacitance at Hz Maximum individual: nf/km. For cables of equal or more than pairs: maximum average: nf/km. cables of low level mutual capacitance ( nf/km) are also available Maximum capacitance unbalance at Hz in pf per meters length of cable Individual value (pf) % values (pf), &. mm. mm, &. mm. mm Pair-to-pair Side-to-side Pair-to-earth 7 Side-to-earth 7 Maximum calculated attenuation at Hz and ºC ø mm.7 db/km ø mm. db/km ø. mm. db/km ø. mm. db/km

number of pairs 7 7 7 7 AERIAL NETWORK CABLE USED IN DISTRIBUTION Foam skin Polyethylene insulated - Double steel tape armoured Polyethylene sheathed - Steel messenger (maximum average mutual capacitance nf/km) Conductor............... Usual number of spare pairs Approx. cable core 7 7 sheath thickness Inner Outer. Messenger Dim. Nbr.X dia. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. 7 X. Mini. break load (dan) 7 7 7 7 Nom. outer dimension hght. X dia. X. X. X. X 7. X. X X X X.7 X. X. 7 X. X X 7 X 7 X X. X. 7 X 7. X X X X 7 X X. X. X 7 X 7 X X X * Other conductor gauges, mutual capacitances, different pair count cables and different delivery lengths are also available.... lineic weight (Kg/Km) 7 7 7 7 7 7 77 7 Usual nominal delivery length (m) Typical conditions of laying: Maximal distance between the supports (span): m. sag for a m span at ºC without overload:. m. security coefficient > in the following extreme climatic conditions: Hypothesis A : km/h wind speed (pressure: pa) at ºC. Hypothesis B : km/h wind speed (pressure: pa) - ºC without ice. security coefficient > in the following extreme climatic conditions: Hypothesis C : ice sleeve of mm thickness at - ºC without wind.

INDOOR USE TELEPHONE CABLES USED FOR TELEPHONE EXCHANGES, SWITCHBOARD & PRIVATE TELEPHONE Specification: Based on IEC -/ PVC insulated PVC sheathed Types and Applications LIBTEL LIBTLV LIBTLS LIBTLA Indoor surface and conduit wiring Switchboard cable, tinned conductors Screened Armoured for use where mechanical stresses are encountered CONSTRUCTION Conductors Copper -. mm bare or tinned. Insulation PVC coloured in the mass with surface ring marking for identification. Twisting Pair or other as request. Stranding Concentric including earth continuity insulated tinned wire, protected with overlapped non-hygroscopic tape. Identification of conductors : see annex B. Moisture barrierand screen ( S - type ) Aluminium foil applied with overlap. Armour ( A - type ) double steel tape applied on inner PVC sheath. Outersheath Grey PVC : A rip cord is laid up under the sheath for easy stripping. LIBTEL LIBTLS LIBTLA Usual electrical characteristics Loop resistance at ºC in direct current, max mm tinned. mm tinned.. ohm / km ohm / km ohm / km ohm / km Mutual capacitance at Hz Maximum : nf/km. Insulation resistance min. MΩ.km

INDOOR USE TELEPHONE CABLES PVC insulated and PVC sheathed Type LIBTEL LIBTLV Type LIBTELS Type LIBTELA number of pairs Overall Net weight kg / km Overall Net weight kg / km Overall Net weight kg / km Standard Packing Delivery length m CONDUCTOR DIAMETER mm.. 7... --- --- --- --- --- --- C C C... 7... --- --- --- --- --- --- C C C 7..7....7 7 7 --- --- --- --- --- --- C C C. 7.7. 7.. 7 7 D D D / / /. 7. 7. D D D / / / 7 7. 7 7. 7. 7 7. 77 D D D / / / Standard Packing : C : Coils D : Drums Other Sizes are also available

JUMPER WIRE Application These cables are intended for inside distributing frame jumper wiring Types JW JWV JWN JWVN PVC insulated tinned copper wire, PVC insulated PVC insulated, nylon jacketed same as JWN but with tinned conductor CONSTRUCTION Conductor Solid, annealed, bare or tinned copper wire, mm. Insulation PVC coloured for identification. Jacket (type JWN and JWVN) abrasion resistant nylon. Stranding Two to five conductors twisted together. Electrical characteristics at ºC Conductor resistance : max Ω / km Insulation resistance : min MΩ / km DIMENSIONAL CHARACTERISTICS Type JW/V Type JWN Number of conductors Overall Net weight kg / km Overall Net weight kg / km Delivery length ( coils ) m CONDUCTOR DIAMETER mm...........7..7..7..

DROP WIRE Application These cables are intended for connecting telephone aerial cable to the subscriber s premises Types DWIRE DWIREY Hard copper conductor, PE jacketed Hard copper conductor, PVC jacketed CONSTRUCTION Conductor Hard copper wire Laid-Up The two conductors are laid-up parallel and jacketed. A ridge is longitudinally extruded along one edge for conductor identification Jacket DWIRE type : Black polyethylene type C to BS DWIREY type: Hard PVC tightly adhered to the conductor type to BS 7 Type DWIRE Electrical characteristics at ºC Conductor resistance, max. - Hard drawn copper. mm. mm. mm... Insulation resistance, min. - PE jacketed - PVC jacketed MΩ. km MΩ. km Copper Conductor mm... DIMENSIONAL CHARACTERISTICS Jacket nature PE PE PE Overall dimensions width x height mm. X.7.7 X.. X. Ω / km Ω / km Ω / km Net weight kg / km Delivery length (coils) m DWIREY... PVC PVC PVC. X.7.7 X.. X. 7

ANNEX A IDENTIFICATION OF CONDUCTORS AND UNITS AND CABLE CORE CONSTRUCTION OF UNDERGROUND AND AERIAL NETWORK CABLES ( any othercombination remaining also available on request ) Identification of conductors Pair Nº Colourof insulation Cond. A Cond. B Pair Nº Colourof insulation Cond. A Cond. B blue orange green brown grey 7 red red red red red blue orange green brown grey sub-unit of base ( pairs ) Identification of basic sub-units, construction of and pair units, and cable cores of up to pairs pairs pairs pairs 7 pairs pairs Identification of basic units and cable core constructions forcables of more than pairs - Numbered units 7 pairs ( x p) pairs ( x p) pairs ( x p) pairs ( x p) 7 7 pairs ( x p) pairs ( x p) pairs ( x p) pairs ( x p)

Identification of basic units and cable core constructions forcables of more than pairs - Numbered units ( continuation ) 7 7 pairs ( x p) pairs ( x p) 7 7 7 pairs ( x p) pairs ( x p) 7 7 pairs ( x p) 7 7 pairs ( x p) 7 7 7 7 pairs (7 x p) 7 7 7 pairs ( x p)

ANNEX B Identification of conductors in Indooruse telephone cables - LIBTEL Pair Nº 7 7 7 etc... WireA Red Blue Yellow Green Black Red Blue Yellow Green Black Red Blue Yellow Green Black Red Blue Yellow Green Black Red Blue Yellow Green Black Red Blue Yellow Green Black Red Blue Colorcode Wire B Basic Ring Red Red Red Red Red Blue Blue Blue Blue Blue Yellow Yellow Yellow Yellow Yellow Green Green Green Green Green Black Black Black Black Black - Color of insulation of triad Wire A : Blue Wire B : Wire C : Red