Drop cables. Vorstadt 32 CH, 6304 Zug Switzerland.
|
|
- Meagan Joseph
- 8 years ago
- Views:
Transcription
1 Drop cables Vorstadt 32 CH, 6304 Zug Switzerland AG
2 Brief Introduction Teletronik RG series coaxial cable was developed to meet the increasing demand of tomorrow's broadband networks. RG series cable has the highest reliability and flexibility of any coaxial cable, low RF attenuation and an unprecedented 10 year warranty. RG series is optimized for use in broadband feeder plants. It offers lower attenuation than other traditional products, with unmatched flexibility, reliability and cost effectiveness. Explanation of codes RG6-S60-F RG11-T60-M-CCS Flooding compound Copper covered steel center conductor Messenger % braid coverage Standard shield 6 series drop cable % braid coverage Tri-shield 11 series drop cable Braid coverage description Percent of coverage = (2F - 2 F 2 ) x 100 Where: And: F A C = = = NPd/Sin A Tan -1 2 π (D + 2d) (P/C) Number of carriers (groups of ends) Suffix S = T = Q = F = M = H = CCS = standard tri-shield quad shield flooding compound messenger home cable copper cut steel inner conductor N P d D = = = = Number of ends (strands) per carrier Picks per inch (carrier crossing points) Diameter of individual wire strand (mm) Diameter of structure under the braid (mm)
3 RG59-T60-HCU Tri-shield construction 20 gauge (0,81 mm) copper center conductor Foamed PE, bounded foil, 60% braid, non-bounded tape, PVC jacket White polyvinylcloride jacket Nominal center conductor diameter 0,81 Nominal diameter over dielectric 3,66 Nominal diameter over first shield (tape) 3,84 Nominal diameter over jacket 6,10 Nominal jacket wall thickness 0,76 5 2, , , , ,47 : 215 mm : 330 mm weight: 11 kg , , , , , , , , , , ,64
4 RG6-S60-CCS Sandard construction 18 gauge (1,02 mm) copper covered steel center conductor Foamed PE, bounded foil, 60% braid, PVC jacket Nominal center conductor diameter 1,02 Nominal diameter over dielectric 4,57 Nominal diameter over first shield (tape) 4,75 Nominal diameter over jacket 6,91 Nominal jacket wall thickness 0,76 5 1, , , , ,00 : 215 mm : 360 mm weight: 12,5 kg , , , , , , , , , , ,49
5 RG6-S60-M Standard, messengered construction 18 gauge (1,02 mm) copper center conductor Foamed PE, bounded foil, 60% braid, PVC jacket Minimum breaking strength of messenger 82 kg mm Nominal center conductor diameter 1,02 Nominal diameter over dielectric 4,57 Nominal diameter over first shield (tape) 4,75 Nominal diameter over jacket 6,91 Nominal jacket wall thickness 0,76 Nominal diameter of steel messenger 1,30 5 1, , , , , ,82 : 205 mm : 420 mm weight: 22 kg , , , , , , , , , ,49
6 RG6-T60-HCU-E Tri-shield construction 18 gauge (1,02 mm) copper center conductor Foamed PE, bounded foil, 60% braid, non-bonded tape, PVC jacket Nominal center conductor diameter 1,02 Nominal diameter over dielectric 4,57 Nominal diameter over first shield (tape) 4,75 Nominal diameter over jacket 7,06 Nominal jacket wall thickness 0,76 5 1, , , , ,00 : 270 mm : 280 mm weight: 12,5 kg (2 reels / package) , , , , , , , , , , ,49
7 RG6-T60-HCU-E Tri-shield construction 18 gauge (1,02 mm) copper center conductor Foamed PE, bounded foil, 60% braid, non-bonded tape, PVC jacket White polyvinylcloride jacket Nominal center conductor diameter 1,02 Nominal diameter over dielectric 4,57 Nominal diameter over first shield (tape) 4,75 Nominal diameter over jacket 7,06 Nominal jacket wall thickness 0,76 5 1, , , , ,00 : 270 mm : 280 mm weight: 12,5 kg (2 reels / package) , , , , , , , , , , ,49
8 RG6-T60-CCS Tri-shield construction 18 gauge (1,02 mm) copper covered steel center conductor Foamed PE, bounded foil, 60% braid, non-bonded tape, PVC jacket White polyvinylcloride jacket Nominal center conductor diameter 1,02 Nominal diameter over dielectric 4,57 Nominal diameter over first shield (tape) 4,75 Nominal diameter over jacket 7,06 Nominal jacket wall thickness 0,76 5 1, , , , ,00 : 260 mm : 310 mm weight: 15 kg , , , , , , , , , , ,49
9 RG6-T60-F-CCS Tri-shield, flooded construction 18 gauge (1,02 mm) copper covered steel center conductor Foamed PE, bounded foil, 60% braid, non-bonded tape, flooded for underground, PE jacket Black polyethylene jacket Nominal center conductor diameter 1,02 Nominal diameter over dielectric 4,57 Nominal diameter over first shield (tape) 4,75 Nominal diameter over jacket 7,06 Nominal jacket wall thickness 0,76 5 1, , , , ,00 : 270 mm : 330 mm weight: 13 kg , , , , , , , , , , ,49
10 RG6-T60-M Tri-shield, messengered construction 18 gauge (1,02 mm) copper center conductor Foamed PE, bounded foil, 60% braid, non-bonded tape, PVC jacket, steel messenger Minimum breaking strength of messenger 82 kg mm Nominal center conductor diameter 1,02 Nominal diameter over dielectric 4,57 Nominal diameter over first shield (tape) 4,75 Nominal diameter over jacket 7,06 Nominal jacket wall thickness 0,76 Nominal diameter of steel messenger 1,30 5 1, , , , , ,82 : 200 mm : 430 mm weight: 22 kg , , , , , , , , , ,49
11 RG6-T60-M-CCS Tri-shield, messengered construction 18 gauge (1,02 mm) copper covered steel center conductor Foamed PE, bounded foil, 60% braid, non-bonded tape, PVC jacket, steel messenger Minimum breaking strength of messenger 82 kg mm Nominal center conductor diameter 1,02 Nominal diameter over dielectric 4,57 Nominal diameter over first shield (tape) 4,75 Nominal diameter over jacket 7,06 Nominal jacket wall thickness 0,76 Nominal diameter of steel messenger 1,30 5 1, , , , , ,82 : 295 mm : 340 mm weight: 21 kg , , , , , , , , , ,49
12 RG6-Q60 Quad-shield construction 18 gauge (1,02 mm) copper center conductor Foamed PE, bounded foil, 60% braid, non-bounded tape, 32% braid, PVC jacket White polyvinylcloride jacket Nominal center conductor diameter 1,02 Nominal diameter over dielectric 4,57 Nominal diameter over first shield (tape) 4,75 Nominal diameter over jacket 7,62 Nominal jacket wall thickness 0,86 5 1, , , , ,00 : 245 mm : 330 mm weight: 12 kg cable lenght: 200 m , , , , , , , , , , ,49
13 RG11-S60-CCS Standard construction 14 gauge (1,63 mm) copper covered steel center conductor Foamed PE, bounded foil, 60% braid, PVC jacket Nominal center conductor diameter 1,63 Nominal diameter over dielectric 7,11 Nominal diameter over first shield (tape) 7,29 Nominal diameter over jacket 10,03 Nominal jacket wall thickness 1,07 5 1, , , , ,23 : 360 mm : 395 mm weight: 24 kg 250 6, , , , , , , , , , ,27
14 RG11-S60-M Standard, messengered construction 14 gauge (1,63 mm) copper center conductor Foamed PE, bounded foil, 60% braid, PVC jacket, steel messenger Minimum breaking strength of messenger 166 kg mm Nominal center conductor diameter 1,63 Nominal diameter over dielectric 7,11 Nominal diameter over first shield (tape) 7,29 Nominal diameter over jacket 10,03 Nominal jacket wall thickness 1,07 Nominal diameter of steel messenger 1,83 5 1, , , , , ,72 : 350 mm : 440 mm weight: 38 kg 300 7, , , , , , , , , ,27
15 RG11-T60-HCU Tri-shield construction 14 gauge (1,63 mm) copper center conductor Foamed PE, bounded foil, 60% braid, non-bounded tape, PVC jacket White polyvinylcloride jacket Nominal center conductor diameter 1,63 Nominal diameter over dielectric 7,11 Nominal diameter over first shield (tape) 7,29 Nominal diameter over jacket 10,03 Nominal jacket wall thickness 0,99 5 1, , , , ,23 : 360 mm : 400 mm weight: 35 kg 250 6, , , , , , , , , , ,27
16 RG11-T60-CCS Tri-shield construction 14 gauge (1,63 mm) copper covered steel center conductor Foamed PE, bounded foil, 60% braid, non-bounded tape, PVC jacket Nominal center conductor diameter 1,63 Nominal diameter over dielectric 7,11 Nominal diameter over first shield (tape) 7,29 Nominal diameter over jacket 10,03 Nominal jacket wall thickness 0,99 5 1, , , , ,23 : 365 mm : 370 mm weight: 35 kg 250 6, , , , , , , , , , ,27
17 RG11-T60-F-CCS Tri-shield, flooded construction 14 gauge (1,63 mm) copper covered steel center conductor Foamed PE, bounded foil, 60% braid, non-bounded tape, flooded for underground, PE jacket Black polyethylene jacket Nominal center conductor diameter 1,63 Nominal diameter over dielectric 7,11 Nominal diameter over first shield (tape) 7,29 Nominal diameter over jacket 10,03 Nominal jacket wall thickness 0,99 5 1, , , , ,23 : 355 mm : 440 mm weight: 25 kg 250 6, , , , , , , , , , ,27
18 RG11-T60-M Tri-shield, messengered construction 14 gauge (1,63 mm) copper center conductor Foamed PE, bounded foil, 60% braid, non-bounded tape, PVC jacket, steel messenger Minimum breaking strength of messenger 166 kg mm Nominal center conductor diameter 1,63 Nominal diameter over dielectric 7,11 Nominal diameter over first shield (tape) 7,29 Nominal diameter over jacket 10,03 Nominal jacket wall thickness 0,99 Nominal diameter of steel messenger 1,83 5 1, , , , , ,72 : 350 mm : 440 mm weight: 40 kg 300 7, , , , , , , , , ,27
19 RG11-T60-M-CCS Tri-shield, messengered construction 14 gauge (1,63 mm) copper covered steel center conductor Foamed PE, bounded foil, 60% braid, non-bounded tape, PVC jacket, steel messenger Minimum breaking strength of messenger 166 kg mm Nominal center conductor diameter 1,63 Nominal diameter over dielectric 7,11 Nominal diameter over first shield (tape) 7,29 Nominal diameter over jacket 10,03 Nominal jacket wall thickness 0,99 Nominal diameter of steel messenger 1,83 5 1, , , , , ,72 : 360 mm : 440 mm weight: 41 kg 300 7, , , , , , , , , ,27
Trunk Cables. www.teletronik.com
Trunk Cables www.teletronik.com Brief Introduction Teletronik TC series coaxial cable was developed to meet the increasing demand of tomorrow's broadband networks. TC series cable has the highest reliability
More informationCommercial Coaxial Cable
Commercial Coaxial Cable For the Best in COMMERCIAL TV Reception Solutions! Do you require a Digital TV reception system for your next project? Matchmaster can supply For The Best Design and supply of
More informationTFC/U-JIN Coaxial Cable Product Information Sheet Type: TU6T60-JVB
Type: TU6T60-JVB Dielectric 2nd Outer (w/optional Floodant) Series 6 Coaxial Cable Copper Clad Steel Foamed Polyethylene Dielectric Bonded AP Laminate Shield 60% Aluminum Braid "Life Time" compound AP
More informationTRUNK CONNECTORS. CH-QR pin type connector for 540 and 715 QR type cables 540-CH-QR 3,15 15,5 29 32 29 715-CH-QR 4,2 20 35 34 34
TRUNK CONNECTORS CH-QR pin type connector for 540 and 715 QR type cables Part number Center cond. diameter (mm) Cable outer diameter (mm) DIMENSION (mm) A B C 540-CH-QR 3,15 15,5 29 32 29 715-CH-QR 4,2
More informationUniprise Solutions COAX 101. White Paper. www.commscope.com
Uniprise Solutions COAX 101 White Paper www.commscope.com Structured cable systems have very thorough standards for fiber optic and twisted pair installations. The cabling components and installed systems
More informationSetting a Higher Standard
Setting a Higher Standard c2 Our people are fearless about pursuing new ideas for solutions to our customers needs. PPC s Perfect Flex Broadband Coaxial Cable continues this commitment of unmatched innovation,
More informationC 060 CCTV Coaxial Cable
C 060 CCTV Coaxial Cable These cables are used for video transmissons of CCTV applications..4...... Coaxial Cable (C 060).. Inner Conductor : Ø 0.60 mm Bare Copper.. Insulation : Ø.80 mm Gas-injected Foam
More informationcoaxial cable coaxial Cable CERTIFIED 100% certified coaxial cable A cable that is marked Televés, no doubt is a certified cable
COAXIAL CABLE coaxial Cable 100% certified coaxial cable coaxial cable CERTIFIED The step ahead undertaken by Televés to improve its service and technical excellence, is now reflected in this new challenge.
More information75 Ω Transmission System
NRAO NTC-DSL Laboratory Report Dynamic Spectroscopy Laboratory Report Series Report 03 September, 2006 75 Ω Transmission System Chaitali R. Parashare Department of Electrical and Computer Engineering,
More informationSemi-rigid Coaxial Cables
50 Ohm RF Coaxial Cables Semi-rigid Coaxial Cables SR034 SR047/M17 SR086 /M17 SR086-25 SR086-75 SR090-25 SR141 SR141-25 SR141-35 SR141-75 SR250 SR250-75 147 Semi-rigid Coaxial Cabless SR034 Inner conductor
More informationOutside Telephone Cable
Outside Telephone Cable Filled Core. Moisture Barrier. Description Soft copper wires insulated with high density polyethylene, foam skin or solid. Filled core, conformed by groups of pairs or by unit of
More informationLOW LOSS CABLE PAG. 1
LOW LOSS CABLE PAG. 1 INTRODUCTION Following many requests we received regarding the need for low-loss custom cable assemblies, we have set up a special production of high performance coaxial cable assemblies
More information1236421A5-N/3GT30G-FLEX3-75 Conector Hembra, Crimp Tipo 1.0/2.3 (PUSH-PULL), 75 Ohm. Cable:Flex 3 /75
CONECTORES COAXIALES RF 1.0/2.3 1.0/2.3 1.0/2.3 www.intersac.pe 1231111L1-002-N/5GT5G-75 Conector Macho, Crimp Tipo 1.0/2.3 (PUSH-PULL), 75 Ohm. Cable:Flex 3 /75 1236421A5-N/3GT30G-FLEX3-75 Conector Hembra,
More informationCable Products HONEYWELL SECURITY & CUSTOM ELECTRONICS. Honeywell's Genesis Series provides a full range
HONEYWELL SECURITY & CUSTOM ELECTRONICS Cable Products Honeywell's Genesis Series provides a full range of low voltage cables for security, fire, sound, voice and data, video, structured cabling and other
More informationRF & Microwave cable assemblies C291
ERTIFIED C AS 9100 RF & Microwave cable assemblies C291 B CONTENTS Pages Introduction... B-4 Specify the right cable for your application... B-5 Finder guide cables vs insertion loss... B-6 to B-7 Flexible
More informationOutdoor Carrier Class Shielded Ethernet Cable. Datasheet. Models: PRO, CARRIER, Connectors. Increase Performance. Extreme Weatherproof
Datasheet Outdoor Carrier Class Shielded Ethernet Cable Models: PRO, CARRIER, Connectors Increase Performance Extreme Weatherproof ESD Damage Protection Extended Cable Support 1 2Datasheet Protect your
More informationGulf Cable & Electrical Ind. Co.
CONTENTS INTRODUCTION PRODUCT RANGE I PRODUCT DATA TABLES Irrigation 1 Coaxial s for T.V/ Satellite Antenna etc 2 Data Transmission s - 4 pair 24 AWG 3 TELEPHONE CABLES Telephone cables CCP-LAP & CCP-LAP-SS
More informationULTIMATE SNAP-N-SEAL
ULTIMATE SNAP-N-SEAL F Series Compression Connectors Thomas & Betts introduces the Ultimate Snap-N-Seal Compression Connector, the newest addition to the Snap-N-Seal system. Look for the classic design
More informationCommunication, Signal & Data Cables
Communication, Signal & Data Cables Used for indoor installation and interconnection of transmission, telephone, telegraph and electronic equipment as well as media equipments www.alfanar.com Communication
More informationCoaxial Cable Solutions Guide
Coaxial Solutions Guide General offers a complete line of Carol Brand Coaxial s for today s sophisticated high-speed, wide-bandwidth electronics products that run over long distances with minimal signal
More informationQuality Reliability Innovation. ISO 9001 : 2000 CERTIFIED BY AFAQ No. QUAL / 1997 / 7034 a COPPER TELECOMMUNICATION CABLES
Quality Reliability Innovation ISO : CERTIFIED BY AFAQ No. QUAL / 7 / 7 a COPPER TELECOMMUNICATION CABLES COPPER TELECOMMUNICATION CABLES CONTENTS 7 NOTICE INTRODUCTION QUALITY ASSURANCE RECOMMENDED ORDERING
More informationCoaxial Cables. for Broadband Communication Networks. European Edition
Coaxial Cables for Broadband Counication Networks European Edition Dependable Solutions in Cabling Better by design Our strategic objective is to provide our customers with superior solutions for their
More informationCOAX Cables Radio Frequency Cables
COAX Cables Radio Frequency Cables Contents Page Table of contents Pictographs General information Introduction Types and abbreviations Temparature range Construction Characteristics Special constructions
More informationMICROCABLES. A complete vision of your connectivity needs. Catalogue
MICROCABLES A complete vision of your connectivity needs Catalogue ELECTRONIC Filotex Introduction Application Nexans s line of microcables is designed towards the increasing requirements of electronics
More informationRoHS DATA, COAXIAL AND ELECTRONIC M.R. D A TA, C O A X I A L, ECOLGICAL Telecom Cables A N D EL E CTRON I C. Cables
RoHS DATA, COAXIAL AND ELECTRONIC D A TA, C O A X I A L, A N D EL E CTRON I C Cables Index SOLID MULTI-CONDUCTOR CABLES STRANDED MULTI-CONDUCTOR CABLES SPEAKER/ZIP WIRE THERMOSTAT CABLE FIRE ALARM CABLE
More informationDiscover. TIMES MICROWAVE SYSTEMS A Smiths Industries company
Discover TIMES MICROWAVE SYSTEMS A Smiths Industries company Discover TIMES MICROWAVE SYSTEMS Discover... a coax cable with excellent RF performance, that's flexible and non-kinking with easy to install
More informationShielding Effectiveness Test Method. Harbour s LL, SB, and SS Coaxial Cables. Designs for Improved Shielding Effectiveness
Shielding Effectiveness Test Method Harbour s LL, SB, and SS Coaxial Cables Designs for Improved Shielding Effectiveness Harbour Industries 4744 Shelburne Road Shelburne Vermont 05482 USA 802-985-3311
More informationRF cables. Edition 2015
RF cables Edition 2015 Developed for highest expectations Your partner for system solutions HUBER+SUHNER is a leading international producer and supplier of electrical and optical interconnectivity components
More informationTimes Microwave Systems Hermetically Sealed Assemblies
SCOPE This Specification details the Electrical, Mechanical and Environmental Characteristics of Times Microwave Systems MILTECH 340.34 Diameter Hermetically Sealed Coaxial Transmission Lines. This product
More informationEcoFlex Cable. Smaller. Lighter. Tougher. 100% Recyclable.
EcoFlex Cable Smaller. Lighter. Tougher. 100% Recyclable. Total Performance, Completely Recyclable EcoFlex cable is Alpha Wire s newest innovation in control cabling. A true engineering breakthrough, EcoFlex
More informationCable Guide. Cables, Connectors & Tools for installation of quality networks. TRIAX - your ultimate connection
Cable Guide Cables, Connectors & Tools for installation of quality networks TRIAX - your ultimate connection A Selection of the best Triax TX Cable range optimised for digital reception Simplification
More informationDesign Techniques for High Power RF Coaxial Cable Assemblies
Design Techniques for High Power RF Coaxial Cable Assemblies Tony Martiniello Chief Technology Officer Primary Considerations Performance Electrical-Mechanical-Environmental Application Prioritizing-Trade-offs
More informationFIRE RESISTANT CABLE CONSTRUCTION OF CABLES
FIRE RESISTANT CABLE In all fire disasters, fire smoke, heat and toxic fumes are the main obstacles to safe evacuation of a building or area. A major contribution towards overcoming these hazards is the
More informationCoaxial Cable 5. Electronics
Electronics Coaxial Cable 5 Index Page Coaxial Solutions Guide 86-87 88-93 RG 8/U Type 94-95 96-99 To meet the needs of today s sophisticated, high-speed, wide bandwidth electronics over long distances,
More informationCoaxial Cables for Medium-Frequency Applications
Coaxial Cables for Medium-Frequency Applications Coaxial Cables for Medium-Frequency Applications Introduction Telecommunications technology is moving forward rapidly and the need for fast and reliable
More informationSpecializing in the cable business for over 38 years, PT. SUPREME CABLE
Specializing in the cable business for over 38 years, PT. SUPREME CABLE MANUFACTURING & COMMERCE Tbk. (PT. SUCACO Tbk) has grown steadly to become a largest and leading cable manufacturer, with international
More informationETHERLINE Ethernet Cable, Connectors & Tools
Ethernet Cable, ors & Tools 2 Pair 242 4 Pair 249 Industrial Ethernet ors & Tools 256 Ethernet Cable, ors & Tools ETHERNET CABLE, CONNECTORS & TOOLS Quick Select Chart 240 2 Pair 2 Pair: CAT.5/5e; Stationary
More informationThe Quality Connection. Cable Solutions for Mobile Networks Business Unit Telecom
The Quality Connection Cable Solutions for Mobile Networks Business Unit Telecom Connection Technology for Wireless Communication Systems A consistent focus on the market, in-depth sector and product knowledge,
More informationSiemens Energy & Automation. structured. WIRING Product Training Series: Advanced Video Session 3
s structured WIRING Product Training Series: Advanced Video Session 3 1 Table of Contents This presentation will give you a closer look at Video in Structured Wiring applications. The following Areas will
More informationMacArtney Underwater Cables - In stock
MacArtney Underwater Cables - In stock The MacArtney Group depends on the support of a number of major cable manufacturers to supply a range of cables that are designed, manufactured and tested to meet
More informationBroadcast and Commercial AV Cabling MASTER CATALOG
Broadcast and Commercial AV Cabling MASTER CATALOG Clark Wire & Cable 408 Washington Blvd. Mundelein, IL 60060 800-222-5348 toll free 847-949-9944 local 847-949-9595 fax www.clarkwire.com Specifications
More informationHARTING Ethernet Cabling 4-poles Overview
Overview RJ45 Connectors [on page 8] System cables [on page 10] Distribution modules and Outlets [on page 20] HARTING PushPull Connectors [on page 22] System cables [on page 24] Panel feed-throughs [on
More informationKNOW YOUR OPTIONS: 230 KV POWER CABLES
KNOW YOUR OPTIONS: 230 KV POWER CABLES 71 CONDUCTOR MATERIAL AND SIZE Conductor material is a matter of both customer preference and required current carrying capacity At 230 kv, copper is most common
More informationCables and Accessories Selection Guide
Cables and Accessories Selection Guide From data centers to robotics to patient monitoring equipment, we re committed to enabling the next generation of faster, smaller and smarter design. 3M offers an
More informationCAVEL VS80205 MADE IN ITALY 1000 V
0,05 9,00 x 7,20 (Pet) (LSZH) Attached CE01 CE02 Sheath Colour black black red Non-migrating Polyester tape longitudinally overlapped (Pet) 25 x 23 µm Outer sheath of Thermoplastic material - black - halogen-free,
More informationSpecification SFTP CAT6 Network Cable 23AWG CU
Specification SFTP CAT6 Network Cable 23AWG CU S/FTP CAT6 Shielded S/FTP PVC Cable 23AWG 4pair Solid, Wooden drum 1000 Grey CAT6 600MHZ CM Shielded (S/FTP) Solid Cable: Our CAT6 600MHZ Shielded (S/FTP)
More informationSection 5 161 kv Power Cables
Know Your Options: 161 kv Power Cable 61 material and size material is a matter of both customer preference and required current carrying capacity Copper conductor common for larger loads When both copper
More informationEMC Test Chamber Solutions RF Cable Assemblies and Connectors
EMC Test Chamber Solutions RF Cable Assemblies and Connectors RF CABLE ASSEMBLY AND CONNECTOR SOLUTONS FOR EMC MMUNTY AND EMSSON COMPLANCE TESTNG E X T N T R A T E D E P T H --> POWER LEVEL: -40.00 dbm
More informationCables. Indoor, Outdoor, HDMI, CAT, connectors. Cables, connectors and tools
Indoor, Outdoor, HDMI, CAT, connectors, connectors and tools Indoor Outdoor Fly leads HDMI CAT F -/IEC connectors F -/IEC adaptors F - terminator Connection cables Power cables and electricity articles
More informationUser s Manual. BNC Mini-High Res, 75 Ohm Termination Kit Connector Installation Guide (60-073-01)
User s Manual BNC Mini-High Res, 75 Ohm Termination Kit Connector Installation Guide (60-073-01) BNC Termination Kit Instructions This document is a compilation of Extron s instructions, together with
More informationKNOW YOUR OPTIONS: 69 KV XLPE POWER CABLE
Know Your Options: 69 kv XLPE Power Cable 3 material and size material is a matter of both customer preference and required current carrying capacity Copper conductor common for larger loads When both
More informationLEAD FREE FIREX. Interlock Armored Cables TECK90 and MC Industrial Cables. w w w. n e x a n s e n e r g y. c o m
FIREX Interlock Armored Cables TECK90 and MC Industrial Cables LEAD FREE O V E R 1 8 0 Y E A R S O F E X P E R I E N C E 866-663-9267 w w w. n e x a n s e n e r g y. c o m Interlock Armored Cables Introduction....2
More informationTest Cable Assemblies
Test Cable Assemblies and Coaxial Passive Components DC-65 GHz 8851 SW Old Kansas Ave. Stuart, FL 34997 USA +1-772-286-9300 +1-800-544-5594 sales@emc-rflabs.com www.emc-rflabs.com Premium Test Cable Lab-Flex
More informationCable Analysis and Fault Detection using the Bode 100
Cable Analysis and Fault Detection using the Bode 100 By Stephan Synkule 2014 by OMICRON Lab V1.3 Visit www.omicron-lab.com for more information. Contact support@omicron-lab.com for technical support.
More informationCoaxial Cables. Table of Contents. Coaxial Cables 6.1
6.1 Table Contents Coaxial Cables 6 Coaxial Cables Page Introduction 6.2 RG Coaxial and Triaxial Reference Guide 6.3 6.15 Broadband: MATV 6.16 Broadband: CATV 6.17 6.28 Series 59: 20 AWG 6.17 Series 6:
More informationFault location on power cables. Fault location on power cables
Fault location on power cables Fault location on power cables Contents: 1. Introduction 2. Construction of power cables 3. Cable faults 01. Introduction Fault location on communication and power cables
More information100% EMI Emission Containment
100% EMI Emission Containment Designed for Longer Service Life Highly Flexible for Easier Handling and Faster Installation Authorized Distributor Industrial VFD Cables Index n Variable Frequency Drive
More informationINSTALLATION PROCEDURES FOR PRINTED CIRCUIT BOARD TERMINATORS D-607-XX
Page: 1 of 9 INSTALLATION PROCEDURES FOR PRINTED CIRCUIT BOARD TERMINATORS D-607-XX 1. SCOPE This engineering standard contains the termination procedures and inspection requirements for the printed circuit
More informationFLEXIBLE COPPER & ALUMINIUM CONNECTIONS. Product Range 1 VGL - ALLIED CONNECTORS
Product Range ROUND STRANDED COPPER CABLE Electrolytic Copper / Oxygen Free Copper Conforms to DIN 46438 Standards Finish: Bare Copper / Tinned / Silver-plated ROUND BRAID / ROUND STRANDED CABLE WITH OVERALL
More information400 Series - Mini USB Buccaneer
IP68 Sealed IP68 rated USB V2.0 performance Plug and play capability Shielded system Overmoulded cables Screw coupling PCB versions Dust and waterproof to EN60529 Data rates up to 480Mbs Hot pluggable,
More informationThe Contractor shall furnish and install all shielded power cable suitable for use on this project.
Section 16122 PRIMARY POWER CABLES PART 1 GENERAL: WORK INCLUDED The Contractor shall furnish and install all shielded power cable suitable for use on this project. RELATED WORK Section 16020: Tests SUBMITTALS
More informationT A B L E T 1 T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A
T A B L E T 1 1 of 7 Tests & Inspection Cable PCUT & PCUT-A (Table T1) T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A No. Test Scale MOC Requirements G 20:10:001:01 Defined Test
More information140 146 rue E. Delacroix / BP 1 F 91211 Draveil cedex FRANCE Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70. Issue 2 01/10/2003-2 -
Space cables Issue 2 01/10/2003-2 - C O N T E N T ESCC Qualified Products Nexans P/N ESCC SP Pages 1871-871 3901/001 359 3/8 1872-872 3901/002 358 9/14 MTV - BTV 3901/013 199 15/19 50 CIS 3902/001.01 189
More informationCoaxial Cable Shields Whitham D. Reeve ( 2012 W. Reeve)
Coaxial Cable Shields Whitham D. Reeve ( 2012 W. Reeve) Introduction This article focuses on the coaxial cable shield, its effectiveness and what to look for when buying cable. The shield is easy to examine,
More informationC A B L E P R O T E C T I O N
Safe cable protection! Elematic Cabling Systems produces in own plants a wide range of products for the cable protection, such as wiring spirals, insulated tubing, heat shrinkable tubing, etc. These products
More informationNetwork Standard Advice No. 1420C 9/6/2011
Network Standard Advice No. 1420C 9/6/2011 TO: Customers, Service Providers and Ausgrid Staff. Advisory Note on Changes to the Use of 11kV Cable Types. Introduction This Network Standard Advice (NSA) provides
More informationCopper Cabling Infrastructure Offering
Copper Cabling Infrastructure Offering High-Speed Copper Cabling Systems The deployment of high speed cabling systems has been increasing rapidly as data centers enable their physical infrastructure with
More informationDirectory chapter 04
M Directory chapter 04 D-Sub Mixed subminiature D connectors New Page D-Sub mixed connector system general information................... 04.02 Contact arrangements............................................
More informationGlobal cable expertise for rolling stock
Global cable expertise for rolling stock Global cable expertise for rolling stock Single and multicore Low voltage control cables Jumper cables HV roof cables (25 kv) rubber cables for power needs of locomotives
More informationLIFE-LINE Safety Cables Continuous Bending Hi-Flex Electrical Cables to Guarantee Safe Cable & Hose Carrier Systems
LIFE-LINE Safety Cables Continuous Bending Hi-Flex Electrical Cables to Guarantee Safe Cable & Hose Carrier Systems Cost-Effective Safe Reliable: LIFE-LINE Cable Carrier Systems Designed by the Experts
More informationBroadband Applications & Construction Manual. Drop Cable Products
Broadband Applications & Construction Manual Drop Cable Products Table of Contents 0.1 Drop Cable Applications and Construction Manual Table of Contents Section 1...Introduction 1.1 Forward 1.2 Drop Cable
More informationMESSENGERS FOR AERIAL CABLE
MESSENGERS FOR AERIAL CABLE COPPERWELD - EHS, 30% CONDUCTIVITY MES(size)CUWELD Size O.D. Stranding Breaking Strength Wgt./Mft. MES1/4CUWELD 1/4".242 7 #12 5,783 lbs. 128 MES5/16CUWELD 5/16".306 7 # 10
More information2 8 k V, 1 / C, T R X L P E I N S U L A T E D, F L A T S T R A P S H I E L D E D C A B L E, C O M P R E S S E D S T R A N D I N G
Seattle Cit y Light 1 of 4 2 8 k V, 1 / C, T R X L P E I N S U L A T E D, F L A T S T R A P S H I E L D E D C A B L E, C O M P R E S S E D S T R A N D I N G 1. Scope This standard covers the detailed requirements
More informationCoaxial cables? Video cables Loudspeaker cables
Photo: ELUKABEL Coaxial cables? Video cables Loudspeaker cables Coaxial cables? Video cables Loudspeaker cables Coaxial cables are used in all areas of the high frequency transmission technology, for example
More informationHARAX circular connector
Show navigation HARAX circular connector Technical characteristics Specifications IEC 60 352-4 IEC 60 9475-2 Approvals HARAX M8-S/M12-S Rated voltage Rated current Diameter of individual strands Conductor
More informationCABLE SPECIFICATION CAN CAB RJ45-SUBD9
CABLE SPECIFICATION All technical information contained in this document is the exclusive property of STI and may neither be used nor disclosed without its prior written consent. AAV 33801 1/8 Connector
More informationUnderstanding Shielded Cable
Understanding Shielded Cable Industrial applications such as the factory floor are typically electrically noisy environments. Electrical noise, either radiated or conducted as electromagnetic interference
More informationAirdac CNE and SNE, 600/1000V, Polyethylene Sheath, SANS 1507, NRS 063 & NRS 017
Airdac CNE and SNE, 600/1000V, Polyethylene Sheath, SANS 1507, NRS 063 & NRS 017 Conductor: Hard Drawn Copper Conductor Class 2 Insulation: LV-XLPE Phase Color Code(SNE): Red, Black & Bare Copper Phase
More informationOutside Plant DS3 Deployment Connectivity Hardware TROMPETER
Outside Plant DS3 Deployment Connectivity Hardware TROMPETER E L E C T R O N I C S, I N C. 3G -WIRELESS PASS THRU JACK MODULE WITH NON-INTRUSIVE SIGNAL MONITORING PORTS One of the problems involved with
More informationUGVCL/SP/591/11KV HT AB CABLE
TECHNICAL SPECIFICATION FOR 11KV AERIAL BUNCHED CABLES FOR OVERHEAD LINES (CROSSED LINKED POLYTHENE DRY GAS CURED) 1. SCOPE This specification covers requirements of XLPE insulated, 11 KV Aerial Bunched
More informationdb MISER ULTRA LOW LOSS CABLE ASSEMBLIES Are you a design or test engineer fighting a challenging loss budget?
db MISER ULTRA LOW LOSS ASSEMBLIES Are you a design or test engineer fighting a challenging loss budget? Consider db Miser ultra low loss cable assemblies. High performance materials, careful attention
More informationRGB Component Video Cable Bundled RGB Coaxial Cables Miniature and High-Flex Type
B R I L L I A N C E B R O A D C A S T C A B L E S 19.69 RGB Coponent Video Cable Bundled RGB Coaxial Cables Miniature and High-Flex RGB coaxial cables are used for sending red, green and blue signals through
More informationCopper Cables CONNECTIVITY & CABLING SYSTEM
Copper Cables CONNECTIVITY & CABLING SYSTEM Category 5E M0502057-91 EN CPR 6707 U/UTP tested up to 200 MHz U/UTP CAT5E, unshielded 4-pair cable (100 Ohm), with PVC or LSZH (Low Smoke Zero Halogen) outer
More informationCOAXICON Contacts. RF Coax Connectors. Product Facts
COXICON Contacts Product Facts Tyco Electronics provides a variety of contacts for coaxial connectors Contacts are available in a range of sizes that may be used with the various types of coaxial cable
More informationCIR. Index. Gexol. Standard CIR UL Listed Type TC-ER. Crush and Impact Resistant Without External Armoring. Arctic CIR UL Listed Type TC-ER-HL*
Gexol CIR Crush and Impact Resistant Without External Armoring Passes the same stringent crush and impact testing required by UL 2225 for Type MC-HL n Available in Standard and Arctic Grade Jackets n Highly
More informationENGINEERING COMMITTEE
ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 02 2006 Specification for F Port, Female, Indoor NOTICE The Society of Cable Telecommunications Engineers (SCTE)
More informationUnarmored Variable Frequency Drive (VFD) Cable Termination Guide
Authorized Distributor Unarmored Variable Frequency Drive (VFD) Cable Termination Guide Be Certain with Belden A Step-by-Step Look at the Connection/Termination of Unarmored VFD Cables Terminating Unarmored
More informationIn-Building Solutions. Wired for Wireless Solution. www.commscope.com
In-Building Solutions Wired for Wireless Solution www.commscope.com Applications: Corporate Offices and Campuses Hospitals Universities Multi-tenant High-Rise Office Buildings Hotels and Casinos Local
More informationBasic Cable Assemblies DELIVERING QUALITY SINCE 1952.
Basic Cable Assemblies DELIVERING QUALITY SINCE 1952. Cable Types Cable Types Hook-up & Lead Wire Most Basic 2 Cable Types Cable Types Twisted Pair Cable A type of cable that consists of two independently
More informationCELLFLEX Foam and HELIFLEX Air Cables
Introduction Cable Jacket Nominal Diameter Cable Minimum Attenuation at Mean Power Type Options Size Over Jacket Weight Bending Radius [] 000MHz [2] Rating at Inch mm (in) kg/m (lb/ft) mm (in) db/00 m
More informationUNDERSTANDING. C&M Corporation 51 South Walnut Street, Wauregan, CT 06387 Phone: 860.774.4812 Fax: 860.774.7330 www.cmcorporation.
UNDERSTANDING UNDERSTANDING NFPA 79 By Ned Lloyd and Mike Levesque NFPA-79 is the electrical standard that has been developed by the National Fire Protection Association (NFPA) and is intended to minimize
More informationFestoon 715 P PUR cable for flexible application in festoon systems
CABLES FOR CRANE AND CONVEYOR APPLICATIONS Festoon 715 P PUR cable for flexible application in festoon systems S AB BRÖCKSKES D-VIERSEN Festoon 715 P 1 x 16.0 mm 2 C Marking for Festoon 715 P 07150162:
More informationCoaxial Cables and Applications Contributed By: Martin J. Van Der Burgt Senior Product Engineering Project Manager, Belden Electronics Division
Coaxial Cables and Applications Contributed By: Martin J. Van Der Burgt Senior Product Engineering Project Manager, Belden Electronics Division Overview: Coaxial cables are perhaps the most common, basic,
More informationA cable for International Quality Standard
www.calendarkabel.com KAB I N T E R N A T I O N A L A cable for International Quality Standard COMMUNICATION CABLES MULTICORE CABLES Highly flexible Non Shielded Multicore Cable. Conforms to EU low-voltage
More informationAPPLICATION ORIENTED DESIGN OF CABLES
APPLICATION ORIENTED DESIGN OF CABLES Mrs. Rohini Bhattacharyya, Dubai cables Ltd.P. O. Box 11529,Dubai. rohinib@ducab.com Mr. Nawaf Ahmad Al Mohaideb Dubai Cables Ltd. P. O. Box 11529, Dubai. Nawaf@ducab.com
More informationENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 123 2011
ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 123 2011 Specification for F Connector, Male, Feed-Through NOTICE The Society of Cable Telecommunications Engineers
More information1394 locking cables. Your locking cables for AVT IEEE 1394 cameras
Your locking cables for AVT IEEE 1394 cameras AVT locking cables are ideal for connection of IEEE 1394 cameras in any industrial application. The high quality cables guarantee low damping and best signal
More information" EXCEEDING EXPECTATIONS WITH PERFORMANCE "
" EXCEEDING EXPECTATIONS WITH PERFORMANCE " Broadcast Cable Video Sales and Ordering Information: -800-245-4964 Technical Questions: E-Mail us at info@westpenn-cdt.com Sales Department: E-Mail us at wpwsales@westpenn-cdt.com
More informationMicrophone and Musical Instrument Cable Overview
B R I L L I A N C E B R O A D C A S T C A B L E S 19.3 Microphone and Musical Instruent Cable Overview Flexible Microphone Cables Belden icrophone cable is used for connecting low level icrophones or usical
More informationPROFIBUS cable. for PROFIBUS-PA and -DP 10/63-6.46 EN
for PROFIBUS-PA and -DP 10/63-6.46 EN CPN 080/CPE 080-Ex PROFIBUS-PA basis cable AWG 18, 0.88 mm 2 Use For fixed installation indoor and outdoor, on racks and in conduits. Application Fieldbus cable for
More information