ENERGY. TECSUN DUO (PV) Twin Cables for Photovoltaics



Similar documents
BRÖCKSKES D-VIERSEN PV1-F 4,0 mm BRÖCKSKES D-VIERSEN PV1-F 4,0 mm d d 2 2 C VDE-REG.-Nr /2009

ENERGY. TECWATER S1BN8-F 0,6/1 kv. Cable for Water Application

Festoon 715 P PUR cable for flexible application in festoon systems

PROFIBUS cable. for PROFIBUS-PA and -DP 10/ EN

FLEXIBLE INDUSTRIAL CABLES H07RN-F TENAFLEX SR

CABLES FOR PHOTOVOLTAIC SOLAR ENERGY INSTALLATIONS FOR CLEAN ENERGY

VIPERFLEX ELECTRIC CABLE

Global cable expertise for rolling stock

PROFIBUS cable. PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications

with coloured cores and overall copper screen UL/CSA... 17

CONFLEX ELECTRIC CABLE

COAX Cables Radio Frequency Cables

Fire Resistant Cables

BETAtrans. Cables and Systems for Rolling Stock. Edition 2006

INTERNATIONAL STANDARD

MV CABLE TYPE C

Power and Wiring Cables

The Quality Connection. BETAflam Fire Resistant Safety Cables

VDE-approved PVC-Control Cables

RADOX railway cables acc. to EN and EN Edition 2009

International Electrotechnical Commission Standards

AFUMEX LSX LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 BASEC APPROVED PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:

KAT a-E. Product Overview Cables

RELIABLE AND EFFICIENT MINING MINING CABLES

RAIL /// WIRE & CABLE WHERE THE BEST IDEAS IN RAIL BEGIN

Flygt flexible cables

Flexible cables for submersible products

Fire retardant IEC

FIRE RESISTANT CABLES FP200 GOLD

Conductix-Wampfler Cables for Reeling Systems

Series 8146/5-V37 and Series 8150/5-V37

ISO 9001 ISO CABLES AND WIRES CATALOGUE 2008

Traveling Cable for Crane.

Flexible Control Cables

Renewable energy. Inverters - Socomec G-1. Load break switches (Isolators) - Socomec G-2. Fuses - df G-3. Fuse bases.

DATA SHEET SERVO LK SMS FX8PLUS SIGNAL

< SD 200 C TP Continuously flexible TPE/PUR paired data cable with coloured cores and overall copper screen... 10

Ampacity simulation of a high voltage cable to connecting off shore wind farms

FIBER-OPTIC CABLES LWL-KABEL

Allweather and Rubber Cables

Chemical resistance Accidental

CAVEL VS80205 MADE IN ITALY 1000 V

LEAD FREE FIREX. Interlock Armored Cables TECK90 and MC Industrial Cables. w w w. n e x a n s e n e r g y. c o m

Instrumentation Cable Power Cable Assembly Solutions...32

PVC YALITIMLI SÝNYAL VE KONTROL KABLOLARI PVC INSULATED SIGNAL AND CONTROL CABLES (VDE 0812-VDE 0814-VDE 0245)

CIR. Index. Gexol. Standard CIR UL Listed Type TC-ER. Crush and Impact Resistant Without External Armoring. Arctic CIR UL Listed Type TC-ER-HL*

The Quality Connection. Cable Solutions for Mobile Networks Business Unit Telecom

PCB transformers. Short circuit proof PCB transformer VB. General Data. Advantages. Applications. Circuit diagram. Standards & 1 Certifications W v

CABLE CLAMPS FOR SINGLE- AND MULTI-CORE CABLES

UGVCL/SP/591/11KV HT AB CABLE

FIRE RESISTANT CABLE CONSTRUCTION OF CABLES

High-ohmic/high-voltage resistors

Temperature Permissible ambient temperature. Weather Resistance to severe weather conditions. Impacts Cable mechanical resistance to impacts

Corporate Profile ROYAL. MODERN ROYAL ELECTRIC Ideal Power Solution MRE ELECTRICAL, INSTRUMENTATION & COMMUNICATION SYSTEMS

ROLLING STOCK CABLES

Gexol. Gexol. The Global Cable Solutions Company. Designed for safe, reliable performance in the harshest oil and gas operating environments

Tri-Rated Flexible PVC Equipment Wire

Digital input modules

CLI CableLine Laser-printed Identification Cable markers and wire markers. Product information

CABLE 101. The Basics of Wire & Cable. Copyright 2007, Belden Inc.

Flexible and safe solutions, for decades. Cables for alarmand safety systems

CABLE SPECIFICATION CAN CAB RJ45-SUBD9

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

6000 Series Buccaneer

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

1 POLE 5 A (CADMIUM FREE CONTACTS TYPE) NY SERIES

FOREWORD ONE OF THE WORLD S BIGGEST COMPANIES IN THE SECTOR.

Electrical Safety Products

Cables for Cranes, Lifts and Handling Systems

Copper Cables CONNECTIVITY & CABLING SYSTEM

100% EMI Emission Containment

New Cable Tie Type Classifications

VdS en. VdS Guidelines for water extinguishing systems. Non-return valves. Requirements and test methods. VdS en : (01)

7 Lighting Technology

Coaxial cables? Video cables Loudspeaker cables

Contact Hueson Corporation for additional information or details Sutton Street Northbridge, MA

Technical application guide IP codes in accordance with IEC 60529

Type XHHW-2 or RHH/RHW-2/USE-2 GenFree II LSZH XLPO Single Conductor

High Voltage Systems. Today. The history of cables

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

B05: Cable protection and sheathing

Section kv Power Cables

Comprehensive safety concepts for building applications

5SV Residual Current Protective Devices

PTC-Resistor Temperature-Sensors MINIKA to DIN and DIN

R.C.C.B. s two-pole LEXIC

Communication, Signal & Data Cables

WHITE PAPER Fire & safety performance standards

Redundancy Module QUINT-DIODE/40

CompactLogix Power Supplies Specifications

6 ELECTRICAL PARAMETERS

ETHERLINE Ethernet Cable, Connectors & Tools

HARTING Ethernet Cabling 4-poles Overview

1 POLE - 5A SLIM POWER RELAY

POWER ROCKER SWITCH UL, CSA, VDE, TÜV, ÖVE, KEMA, SEMKO, NEMKO, DEMKO, FIMKO, SEV UL, CSA, VDE, TÜV, SEMKO, NEMKO, DEMKO, FIMKO, SEV, KEMA, ÖVE

The optimum material solution for Low Voltage energy cables

1.5. UL flammability ratings. *Nylon 6.6 = Polyamide 6.6 is Halogen-free and Silicone-free.

Thermal-Magnetic Circuit Breaker M1-..

Standard Buccaneer - Ethernet

Transcription:

ENERGY TECSUN DUO (PV) Twin Cables for Photovoltaics

Auswahlkriterien Manufacturer Trademark Approvals Application Prysmian Kabel und Systeme GmbH Kabel- und Leitungswerk Neustadt bei Coburg / Germany TECSUN DUO (PV) PV1-F PRYSMIAN Solar cables TECSUN DUO (PV) are intented for use in photovoltaic power supply systems and similar applications as free movable, free hanging, fixed installation and buried in ground in constructional secured systems. The cables can be used indoor, outdoor, in explosion hazard areas, in industry and agriculture. They are suitable for applications in/at equipment with protective insulation (protecting class II). In other respects IEC 61215 and 61646, IEC 60364-7-712:2002 and DIN VDE 0100 part 520 applies. Technical Data Producer 1 operating voltage in AC systems operating voltage in DC systems Test voltage 0.7/1.2 kv 0.9/1.8 kv AC 6 kv / DC 10 kv (15 min.) Ampacity According to Requirements for cables for PV systems, DKE/VDE AK 411.2.3 Tests According to HD 22.2 - conductor resistance, test voltages AC and DC, electric strength, surface resistance, spark test on insulation, insulation resistance at 20 C and 90 C in water and at 120 C in air. EN 50305 Part 6 - DC-stability (10 days, 85 C, salt water, 1.5 kv DC) TECSUN DUO (PV) Twin Cables for Photovoltaics ambient temperature Minimum permissible temperature operating temperature of the conductor Short-circuit temperature +90 C (stationary and in motion) -40 C (stationary and in motion) +120 C; Interpretation according to IEC 60216: permanent temperature 120 C for 20.000 h (= 2.3 years), at max. 90 C permanent temperature (= 30 years) +250 C (at the conductor max. 5 sec.) Resistance to cold Bending test at low temperature according to DIN EN 60811-1-4 Impact test similar to DIN EN 50305 Damp-Heat Test According to EN 60068-2-78 1.000h at 90 C and 85% humidity

Auswahlkriterien Thermal Parameters Tensile load Minimum bending radii Abrasion 15 N/mm² in operation, 50 N/mm² during installation see selection and ordering data According to DIN EN 53516: against abrasive paper Sheath against sheath (internal testing) Sheath against metal (internal testing) Sheath against plastics (internal testing) Shrinkage test According to EN 60811-1-3 Pressure test at high temperature According to EN 60811-3-1 Dynamic penetration test According to Requirements for cables for PV systems, DKE/VDE 411.2.3 Shore-hardness 85 according to DIN EN 53505 Gnawer resistance An optimum of safety can be achieved with protective hoses and by use of special cable types with metallic coating such as spinning or braid. Chemical Parameters Mineral oil resistance 24h, 100 C according to DIN VDE 0473-811-2-1, DIN EN 60811-2-1 Acid and alkaline resistance According to EN 60811-2-1 7 days, 23 C (N-Oxalic acid, N-Sodium hydroxide) Ammonia resistance Weather resistance Behaviour in case of fire Ecological innocuousness 30 days in saturated ammonia atmosphere (internal testing) Ozone resistance according to DIN EN 50396 test type B, HD 22.2 test type B UV-resistance according to UL 1581 (Xeno-Test), ISO 4892-2 (Method A) and HD605/A1-2.4.20 Absorption of water (gravimetric) according to DIN VDE 0473-811-1-3, DIN EN 60811-1-3 Flame propagation Single cable according to DIN VDE 0482 Part 332-1-2, DIN EN 60332-1-2 Multiple cable according to DIN VDE 0482 Part 266-2-5, DIN EN 50305-9 Low smoke emission according to DIN VDE 0482 Part 268-2, IEC 61034 (light transmittance > 70%) Corrosivity according to DIN EN 50267-2-2 Toxicity according to DIN EN 50305, ITC-index < 3 TECSUN DUO (PV) cables complies with the codes 2000/53/EG, 2002/96/EG, 2003/11/EG and exempt from metallic lead-, mercury-, hexavalent chromium- und bromine containing compounds. RoHS conform.

Aufbaukriterien name wert Conductor Electrolytic copper, tinned, Class 5 according to IEC 60228 (DIN VDE 0295) Insulation Core identification Power Conductor Sheath Sheath-colours Marking TECSUN DUO (PV) HEPR 120 C similar to IEC 60502-1 (compound type EI6 / EI8) positive pole red, Negative pole black EVA 120 C based on DIN VDE 0282 part 1, HD 22.1 (compound type EM4 / EM8) Insulation and sheath are connected solidly (Two-layer-insulation ) black (rhombus) PRYSMIAN TECSUN (PV) PV1-F (cross-section) 0.6/1 KV (VDE- REG./TÜV)

Bestellinformationen Nennquerschnitt und Farbe Cu-Zahl Bestellnummer Leiterdurchmesser Außendurchmesser Mindestwert Außendurchmesser Höchstwert Leitungsgewicht netto ca. min. Biegeradius max. zulässige Zugbelastung Strombelastung bei 30 C [mm] (kg/km) [N] (A) test 2x 4 black - 2.4 5.2 each 5.6 each 116 16.8 60 44 0.50 2x 6 black - 2.9 5.7 each 6.1 each 152 18.3 90 56 0.76 2x10 black - 4.0 6.8 each 7.2 each 240 21.6 150 78 1.26 1x4 + 2x0.5 - - - - - - - - - Irrtümer, Änderungen und Abweichungen vorbehalten. PRYSMIAN Germany Version: 1.0 - Datum: 00.00.0000