Radial Distribution Test Feeders



Similar documents
Chapter 24. Three-Phase Voltage Generation

Impact of electric vehicles on the IEEE 34 node distribution infrastructure

Short Circuit Current Calculations

CHAPTER 2 EXAMPLES AND TABLES

Rule Fast Track Analysis for National Life Insurance Co.

Lecture Notes ELE A6

THREE PHASE CIRCUITS

Estimating Line-Flow Limits

Chapter 12: Three Phase Circuits

Three phase circuits

General Calculations. Excerpt from PRYSMIAN S WIRE AND CABLE ENGINEERING GUIDE

SECTION POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL

Hyperlinks are Inactive

PowerWorld Transmission Line Parameter Calculator

Section kv Power Cables

Modeling and Testing of Unbalanced Loading and Voltage Regulation

Step Voltage Regulators

Modeling of Transmission Lines

How To Wire A Three Phase, Single Phase, Wye Transformer

GENERATOR SELECTION. a. Three phase - 120/208V, 3 phase, 4W wye; 277/408, 3 phase, 4W wye; * 120/240V 3 phase, 4W Delta

KNOW YOUR OPTIONS: 69 KV XLPE POWER CABLE

MODELING AND TESTING OF UNBALANCED LOADING AND VOLTAGE REGULATION. Prepared For: California Energy Commission Public Interest Energy Research Program

KNOW YOUR OPTIONS: 230 KV POWER CABLES

Voltage Drop (Single-Phase)

DISTRIBUTION SYSTEMS INDEX NOV 06 SECTION 2. Detroit Ann Arbor Mt. Clemens Port Huron

Neutral to Earth Voltage Reduction Methods in Three-Phase Four Wire Distribution Systems

1 Introduction. 2 Two Phases. J.L. Kirtley Jr.

Services. Three Phase Service

How To Balance Three Phase Power In A Balanced System

BALANCED THREE-PHASE CIRCUITS

Introduction to PowerWorld Simulator: Interface and Common Tools

Management Systems 10 Electrical Safety Audit 14 PPE 20 Arc Mitigation 22 Hazard Assessment 26

JEFFERSON ELECTRIC, INC. Buck-Boost Transformer Application Manual

SIZING THE PRIMARY POWER SYSTEM FOR RESISTANCE WELDERS

Equipment: Power Supply, DAI, Variable resistance (8311), Variable inductance (8321)

Digital Energy ITI. Instrument Transformer Basic Technical Information and Application

3. TYPES OF SERVICE AVAILABLE. 3.1 Scope

Fault Analysis I PowerWorld Corporation

Voltage Loss Formula s

Discussion on Class I & II Terminology. IEEE PES Transformers Committee Fall Meeting 2011 Boston, MA

Selecting Current Transformers Part 1 By Darrell G. Broussard, P.E.

Beware of Simplistic Voltage Drop Calculations. By Aaron Hesse, PE, Coffman Engineers, Spokane, Washington INTRODUCTION

THE PER-UNIT SYSTEM. (2) The per-unit values for various components lie within a narrow range regardless of the equipment rating.

Simulation of Cable Overloading Problem on a University Distribution System

Cable Selection for Medium Voltage Capacitor Banks and Harmonic Filter Banks

TRANSFORMER: THREE PHASE

TESLA Recorder Power Metering Setup Configuration for 3 and 2 Element Watt/VAR Metering

HPS Universal. Single and Three Phase Potted. Buck-Boost Transformers. Buck-Boost Applications & Standard Specification... 80

How To Get A Power Line Extension

Direction of current flow through conductor. Fig. 1 Magnetic field generated by current flow

Chapter 12 Three-Phase Circuit

STANDARDS. Site-Specific Loss Adjustments PUBLIC

VOLTAGE CONTROL WITH SHUNT CAPACITANCE ON RADIAL DISTRIBUTION LINE WITH HIGH R/X FACTOR. A Thesis by. Hong-Tuan Nguyen Vu

EEL303: Power Engineering I - Tutorial 4

CUSTOMER REQUIREMENTS AT POWER SUBSTATIONS

The following table shows approximate percentage wise the

Three-phase AC circuits

Static Analysis of Power Systems. Lennart Söder and Mehrdad Ghandhari

3-Phase AC Calculations Revisited

Understanding Power Factor and How it Affects Your Electric Bill. Presented by Scott Peele PE

LEAD FREE FIREX. Interlock Armored Cables TECK90 and MC Industrial Cables. w w w. n e x a n s e n e r g y. c o m

Simulation of Ungrounded Shipboard Power Systems in PSpice

Power Technology Issue 104. Modeling of Two-Winding Voltage Regulating Transformers for Positive Sequence Load Flow Analysis in PSS E

SAMPLE OF THE STUDY MATERIAL PART OF CHAPTER 3. Symmetrical Components & Faults Calculations

Phase Balancing of Distribution Systems Using a Heuristic Search Approach

Power System Harmonics

Modeling Simulation Technology Research for Distribution Network Planning *

APPLICATION ORIENTED DESIGN OF CABLES

Transformer circuit calculations

TERMS AND CONDITIONS

HIGH VOLTAGE CALCULATIONS / EVALUATIONS. West Virginia Office of Miners Health, Safety & Training

Power measurement in balanced 3 phase circuits and power factor improvement. 1 Power in Single Phase Circuits. Experiment no 1

100% EMI Emission Containment

Instrument Transformer Wiring Troubleshooting Guide Three Phase Meters Revision 0, Initial Issue, April 26, 1993

Power Quality Standards for Electric Service

AC Generators. Basic Generator

Three-Phase Electric Power Distribution for Computer Data Centers

Motor Protection Voltage Unbalance and Single-Phasing

Comparison of Power Título Transmission Line Models with Finite Elements

Single and Three Phase Transformer Testing Using Static Motor Circuit Analysis Techniques

4.5 Transformer Connections

LAB1 INTRODUCTION TO PSS/E EE 461 Power Systems Colorado State University

Module Title: Electrotechnology for Mech L7

Power Technology Issue 106. Modeling of Three-Winding Voltage Regulating Transformers for Positive Sequence Load Flow Analysis in PSS E

SECTION DVD01: VOLTAGE DROP/VOLTAGE FLICKER AND TRANSFORMER SIZING GUIDELINES

2 8 k V, 1 / C, T R X L P E I N S U L A T E D, F L A T S T R A P S H I E L D E D C A B L E, C O M P R E S S E D S T R A N D I N G

Department of Labor and Industry Electrical Licensing

Cables, Cable Laying & Accessories Manual

EDS KV TRIPLEX CABLE

Ground Fault Protection on Ungrounded and High Resistance Grounded Systems

Request for Payment Instructions Wholesale Distribution Access Tariff (WDAT) Attachment I - GIP

The electrical energy produced at the gen

Physical Address: City: State: Zip Code:

Grounding of Electrical Systems NEW CODE: Grounding and Bonding

VOLTAGE REGULATOR AND PARALLEL OPERATION

Chapter 9 Balanced Faults

Effective: September 10, 2006 Vermont Attachment 1 to Rule Public Service Board Page 1 of 6

BALANCED THREE-PHASE AC CIRCUIT

Uptown Campus, Primary Electric Master Plan - Program Study State University of New York At Albany, SUCF Project No V.

Alternating current three-phase circuits

Transcription:

Radial Distribution Test Feeders Distribution System Analysis Subcommittee Report Abstract: Many computer programs are available for the analysis of radial distribution feeders. In 1992 a paper was published [1] that presented the complete data for three four-wire wye and one three-wire delta radial distribution test feeders. The purpose of publishing the data was to make available a common set of data that could be used by program developers and users to verify the correctness of their solutions. This paper presents an updated version of the same test feeders along with a simple system that can be used to test three-phase transformer models. Keywords: distribution system analysis, test systems, computer programs, transformer models I. Introduction In recent years many digital computer programs have been developed for the analysis of unbalanced three-phase radial distribution feeders. The programs use a wide variety of iterative techniques and range from very simple with many simplifying assumptions made for line and load models to very sophisticated with little if any simplifying assumptions. With so many different programs available there is a need for benchmark test feeders so that the results of various programs can be compared. This paper presents the complete data for three four-wire wye, one three-wire delta test feeders and a simple feeder for testing three-phase transformer models. Only the data for the 13 node test feeder will be presented in this paper. The complete data and solutions for all of the test feeders can be downloaded from the Internet at http://ewh.ieee.org/soc/pes/dsacom/testfeeders.html. The systems described in this paper were approved by the Distribution Systems Analysis Subcommittee during the 2000 PES Summer Meeting. The paper was written by W. H. Kersting, Professor of Electrical Engineering at New Mexico State University. II. Basic Data The following data will be common for all systems: Load Models: Loads can be connected at a node (spot load) or assumed to be uniformly distributed along a line section (distributed load). Loads can be three-phase (balanced or unbalanced) or single-phase. Three-phase loads can be connected in wye or delta while single-phase loads can be connected line-to-ground or line-to-line. All loads can be modeled as constant kw and kvar (PQ), constant impedance (Z) or constant current (I). Table 1 lists the codes that will be used to describe the various loads. Table 1 Load Model Codes Code Connection Model Y-PQ Wye Constant kw and kvar Y-I Wye Constant Current Y-Z Wye Constant Impedance D-PQ Delta Constant kw and kvar D-I Delta Constant Current D-Z Delta Constant Impedance Single-phase loads connected line-to-line will be assigned delta connection codes regardless of whether the feeder is a four-wire wye or three-wire delta. All of the load data will be specified in kw and kvar or kw and power factor per phase. For constant current and constant impedance loads the kw and kvar should be converted by assuming rated voltage (1.0 per-unit). For wye connected loads, phases 1, 2 and 3 will be connected a-g, b-g and c-g respectively and delta connected loads will be connected a-b, b-c and c-a respectively. Only nonzero loads will be given in the various feeder load tables. All other loads are assumed to be zero. Shunt Capacitors: Shunt capacitor banks may be three-phase wye or delta connected and single-phase connected line-to-ground or line-to-line. The capacitors are modeled as constant susceptance and specified at nameplate rated kvar.

Overhead Spacing Models: The spacing ID numbers and type for overhead lines are summarized in Table 2. Table 2 Overhead Line Spacings Spacing ID Type 500 Three-Phase, 4 wire 505 Two-Phase, 3 wire 510 Single-Phase, 2 wire Figure 1 shows the spacing distances between the phase conductors and the neutral conductor for Spacing ID numbers used for the overhead lines. 2.5 4.5 7.0 # 1/0 AA 0.970 0.368 0.0111 310 # 2 AA 1.54 0.292 0.00883 156 # 2 ACSR 1.69 0.316 0.00418 180 # 4 ACSR 2.55 0.257 0.00452 140 # 10 CU 5.903 0.102 0.00331 80 # 12 CU 9.375 0.081 0.00262 75 # 14 CU 14.872 0.064 0.00208 20 Underground Spacing Models: The spacing ID numbers and type for underground lines are summarized in Table 4. Table 4 Underground Line Spacings Spacing ID Type 515 Three-Phase, 3 Cable 520 Single-Phase, 2 Cable 4.0 4.0 5.0 Figure 2 shows the spacing distances between cables for underground lines: 6" 6" 1" Conductor Data 24.0 24.0 24.0 ID-500 ID-505 ID-510 Figure 1 Overhead Line Spacings Table 3 lists the characteristics of the various conductors that are used for the overhead configurations in the test feeders[2,3 ]. The columns correspond to: 1 Conductor size in AWG or kcmil 2 Type of conductor AA = All Aluminum ACSR = Aluminum Conductor Steel Reinforced CU = Copper 3 60 Hz resistance at 50 degrees C (ohms/mile) 4 Conductor outside diameter (inches) 5 Geometric Mean Radius (ft.) 6 Ampacity at 50 degrees C (amps) Table 3 Conductor Data 1,000 AA 0.105 1.15 0.0368 698 556.5 ACSR 0.1859 0.927 0.0313 730 500 AA 0.206 0.813 0.026 483 336.4 ACSR 0.306 0.721 0.0244 530 250 AA 0.410 67 0.0171 329 # 4/0 ACSR 92 63 0.00814 340 # 2/0 AA 0.769 0.414 0.0125 230 # 1/0 ACSR 1.12 0.398 0.00446 230 Cable Data: ID - 515 Figure 2 Underground Line Spacings Table 5 lists the characteristics of the various concentric neutral cables [4] that are used in the test feeders. The column numbers correspond to: 1 Conductor size in AWG or kcmil 2 Diameter over insulation (inches) 3 Diameter over screen (inches) 4 Outside diameter (inches) 5 Copper 1/3 neutral (No. x AWG) 6 Ampacity in 4 inch duct Table 5 Concentric Neutral 15 kv All Aluminum (AA) Cable 2(7x) 0.78 0.85 0.98 6 x 14 135 1/0(19x) 0.85 0.93 1.06 6 x 14 175 2/0(19x) 0.90 0.97 1.10 7 x 14 200 250(37x) 1.06 1.16 1.29 13 x 14 260 500(37x) 1.29 1.39 1.56 16 x 12 385 1000(61x) 1.64 1.77 1.98 20 x 10 550 Table 6 lists the characteristics of a tape shielded conductor used in the test feeders. The column numbers correspond to: 1 Conductor size in AWG 2 Diameter over insulation (inches) 3 Diameter over the shield 4 Jacket thickness (mils) ID - 520

5 Outside diameter (inches) 6 Ampacity in 4 inch duct (amps) Table 6 Tape Shielded 15 kv All Aluminum (AA) Cable Tape Thickness = 5 mils 1/0 0.82 0.88 80 1.06 165 Configuration Codes: Each test feeder will have a table of Configuration Codes. The configuration code is a unique number assigned to describe the spacing model (Tables 2 and 4), the phasing (left to right) and the phase and neutral conductors used. Line Segment Data: Each test feeder will have a table of Line Segment Data. The data will consist of the node terminations of each line segment (Node A and Node B), the length of the line segment and a configuration code ( Config.). There is no significance in the order in which the data appears or whether node A or node B is closer to the source. Voltage Regulators: Voltage regulators are assumed to be step-type and can be connected in the substation and/or to a specified line segment. The regulators can be three-phase or singlephase. Tap positions will be determined by the compensator circuit settings described by: 1. Voltage Level desired voltage (on a 120 volt base) to be held at the regulating point. 2. Bandwidth the voltage level tolerance usually assumed to be 2 volts. 3. Compensator resistance (R) and reactance (X) settings the equivalent resistance and reactance between the regulator and the regulating point calibrated in volts. 4. PT Ratio turns ratio of the potential transformer feeding the compensator circuit. 5. CT Rating the current rating on the primary of the current transformer feeding the compensator circuit. III. The Test Feeders The data for the feeders is so extensive that only the data for the 13 node feeder will be given in this paper. Data for all of the test feeders can be downloaded from: http://ewh.ieee.org/soc/pes/dsacom/testfeeders.html. The data is in a spreadsheet format. In addition to the data a solution for each of the feeders can be downloaded. The solution consists of: 1. Listing of the per mile phase impedance and admittance matrices for each of the configurations used in the feeder. The impedance matrix assumes a resistivity of 100 Ohm-meters and the admittance matrix assumes a relative permittivity of 2.3. 2. Radial Flow Summary a summary of the system input, total load, total losses and total shunt capacitors by phase and total three-phase. 3. Voltage Profile voltage magnitudes and angles by phase at each node. Voltage magnitudes are given in per-unit. 4. Voltage Regulator Data for each regulator in the system a summary of the settings and the final tap settings. 5. Radial Power Flow complete node data including line flows in amps and degrees by phase. Line power losses by phase and total three-phase are also given. The IEEE 13 Node Test Feeder This feeder is very small and yet displays some very interesting characteristics. 1. Short and relatively highly loaded for a 4.16 kv feeder 2. One substation voltage regulator consisting of three single-phase units connected in wye 3. Overhead and underground lines with variety of phasing 4. Shunt capacitor banks 5. In-line transformer 6. Unbalanced spot and distributed loads For a small feeder this will provide a good test for the most common features of distribution analysis software. The complete data for this system is given below to illustrate the form of the data for all of the test feeders. One Line Diagram 650 646 645 632 633 634 611 684 671 652 680 Underground Line Configuration Data: 692 675 Config. Phasing Cable Neutral Space ID 606 A B C N 250,000 AA, CN None 515 607 A N 1/0 AA, TS 1/0 Cu 520

Overhead Line Configuration Data: Config. Phasing Phase Neutral Spacing ACSR ACSR ID 601 B A C N 556,500 26/7 4/0 6/1 500 602 C A B N 4/0 6/1 4/0 6/1 500 603 C B N 1/0 1/0 505 604 A C N 1/0 1/0 505 605 C N 1/0 1/0 510 Line Segment Data: Node A Node B Length(ft.) Config. 632 645 500 603 632 633 500 602 633 634 0 XFM-1 645 646 300 603 650 632 2000 601 684 652 800 607 632 671 2000 601 671 684 300 604 671 680 1000 601 671 692 0 Switch 684 611 300 605 692 675 500 606 Capacitor Data: Node Ph-A Ph-B Ph-C kvar kvar kvar 675 200 200 200 611 100 Total 200 200 300 Regulator Data: Regulator ID: 1 Line Segment: 650-632 Location: 650 Phases: A - B -C Connection: 3-Ph,LG Monitoring Phase: A-B-C Bandwidth: 2.0 volts PT Ratio: 20 Primary CT Rating: 700 Compensator Settings: Ph-A Ph-B Ph-C R - Setting: 3 3 3 X - Setting: 9 9 9 Volltage Level: 122 122 122 Transformer Data: kva kv-high kv-low R - X - % % Substation: 5,000 115 - D 4.16 Gr. Y 1 8 XFM -1 500 4.16 Gr.W 0.48 Gr.W 1.1 2 Spot Load Data: Node Load Ph-1 Ph-1 Ph-2 Ph-2 Ph-3 Ph-3 Model kw kvar kw kvar kw kvar 634 Y-PQ 160 110 120 90 120 90 645 Y-PQ 0 0 170 125 0 0 646 D-Z 0 0 230 132 0 0 652 Y-Z 128 86 0 0 0 0 671 D-PQ 385 220 385 220 385 220 675 Y-PQ 485 190 68 60 290 212 692 D-I 0 0 0 0 170 151 611 Y-I 0 0 0 0 170 80 TOTAL 1158 606 973 627 1135 753 Distributed Load Data: Node A Node B Load Ph-1 Ph-1 Ph-2 Ph-2 Ph-3 Ph-3 Model kw kvar kw kvar kw kvar 632 671 Y-PQ 17 10 66 38 117 68 IEEE 123 Node Test Feeder The IEEE 123 node test feeder operates at a nominal voltage of 4.16 kv. While this is not a popular voltage level it does provide voltage drop problems that must be solved with the application of voltage regulators and shunt capacitors. For programs that can allocate load, this will be a good test feeder to use. There are enough switches in the feeder so that optimal configuration procedures can be tested. This is the most comprehensive feeder and is characterized by: 1. Overhead and underground line segments with various phasing. 2. Unbalanced loading with all combinations of load types (PQ, constant I, constant Z) 3. All loads are spot loads located at a node 4. Four step-type voltage regulators 5. Shunt capacitor banks 6. Switching to provide alternate paths of power-flow This feeder is well behaved and does not have a convergence problem. It provides a test of the modeling of the phasing of the lines. The four voltage regulators provide a good test to assure that the changing of

individual regulator taps is coordinated with the other regulators. The IEEE 34 Node Test Feeder This feeder is an actual feeder located in Arizona. The feeder s nominal voltage is 24.9 kv. It is characterized by: 1. Very long and lightly loaded 2. Two in-line regulators required to maintain a good voltage profile 3. An in-line transformer reducing the voltage to 4.16 kv for a short section of the feeder 4. Unbalanced loading with both spot and distributed loads. Distributed loads are assumed to be connected at the center of the line segment 5. Shunt capacitors Because of the length of the feeder and the unbalanced loading it can have a convergence problem. The IEEE 37 Node Test Feeder This feeder is an actual feeder located in California. The characteristics of the feeder are: 1. Three-wire delta operating at a nominal voltage of 4.8 kv 2. All line segments are underground 3. Substation voltage regulator consisting of two singlephase units connected in open delta 4. All loads are spot loads and consist of constant PQ, constant current and constant impedance 5. The loading is very unbalanced Although there are very few three-wire delta systems in use, there is a need to test software to assure that it can handle this type of feeder. The IEEE Four Node Test Feeder This feeder was not part of the original set of test systems published in 1992. The primary purpose of this test feeder is to provide a simple system for the testing of all possible three-phase transformer connections. Characteristics of the feeder are: 1. Two line segments with a three-phase transformer bank connected between the two segments 2. Data is specified for closed three-phase transformer connections and for two transformer open connections 3. Transformer data is specified for step-up and stepdown testing. The primary voltage is always 12.47 kv while the secondary voltage can be either 4.16 kv or 24.9 kv. 4. Data is specified for balanced and unbalanced loading at the most remote node Test results for this feeder include the following transformer connections for step-down and step-up operations and for balanced and unbalanced loading. 1. Grounded Wye Grounded Wye 2. Grounded Wye Delta 3. Ungrounded Wye Delta 4. Delta Grounded Wye 5. Delta Delta 6. Open Wye Open Delta IV. Summary Data for five different test feeders has been developed. Data appearing in this paper are common to all of the feeders. The total data for the 13 node test feeder is included to illustrate the form of the data for the other test feeders. The data and one-line diagrams for the other test feeders are too extensive to be included in the paper. The data for all five test feeders are in spreadsheet format and can be downloaded from the Web at: http://ewh.ieee.org/soc/pes/dsacom/testfeeders.html The test feeders have been studied using the Radial Distribution Analysis Package of WH Power Consultants, Las Cruces, New Mexico and/or Windmil developed by Milsoft Integrated Solutions, Abilene, Texas. The results of these tests are included with the data for each feeder. Software developers are encouraged to test their software using these test feeders and to publish the results. The hope is that in time there will be agreement on the results in the same way that there is agreement on the various test systems used by network power-flow programs. V. References: 1. IEEE Distribution Planning Working Group Report, Radial distribution test feeders, IEEE Transactioins on Power Systems,, August 1991, Volume 6, Number 3, pp 975-985. 2. J.D. Glover and M. Sarma, Power system analysis and design, 2 nd Edition, PWS Publishing Company, Boston, MA, 1994. 3. Overhead conductor manual, Southwire Company, Carrollton, GA, 1994. 4. Product data, Section 2, Sheets 10 and 30., The Okonite Company, www.okonite.com