Multipoint Scanning Alarm System



Similar documents
Buckeye Detection Systems Fixed Detection Systems Application Survey

Regards from the Team at Rheology Solutions.

Series B14 Monitor System

Unidirectional Transmitter/ Receiver Units Introduction

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

Model: DC-A2IO Advanced HVAC Controller

HONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions V1 Rev A 11/12)

Electronic Control Devices The European Product Catalogue 2007

O C M III. Open Channel Flow Monitor

TrueAlarm Fire Alarm Systems

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

Honeywell Analytics Lines of Business

CB200W Water Leak Detection Panel Application Guide

Controller board and power supply for vivimat III systems

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

Q U A D S C A N I I GENERAL User Interface Enclosure Display QUADSCAN II Temperature Range RECEIVER DISPLAY Sensor Weight Optional Relay Enclosure

Electronic Control Devices The European Product Catalogue 2007

T7560A,B,C Digital Wall Module

Liebert Universal Monitor

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

Fire Pump Controllers Remote Alarm Panels

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

SmartVFD Frame 4 Wiring Diagrams and Dimensional Drawings

SECTION DETECTION AND ALARM

Series Six Plus Programmable Controller

713 Open Channel Flowmeter and Transmitter. All-in-one package for open channel flow measurement.

IMS ALARM 3 PORT RS485 EXPANSION BOX

Short Range Wireless Switch System Handheld 8 Installation and Operations Guide

HM-W536 Install Guide

INTELLIGENT FIRE ALARM CONTROL PANELS. MR-2100/MR-2200 Intelligent Fire Alarm Control Panels MEA. Features. Description

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

Fire Control Panels. Remote Annunciator Panels. UL, ULC, CSFM Listed; FM Approved; MEA (NYC) Acceptance* Features. Introduction

Applied Electronics. Commercial Dimming System UPDATE NOTICE

Disabled Toilet Alarm. Contractor Pack. Installation & Operating Instructions

NELSON VOLTAGE MONITOR INSTALLATION & PROGRAMMING MANUAL

SECTION FIRE ALARM AND SMOKE DETECTION SYSTEMS

Measurement. SITRANS F US Inline. Transmitter FUS080/FUE080 4/219

AC-115 Compact Networked Single Door Controller. Installation and User Manual

T775U Series 2000 Electronic Stand-Alone Controller

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

Installation Requirements

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

EQUIPMENT SPECIFICATIONS

VLT Series 3500 Adjustable Frequency Drive Instruction Manual

Alliance System Ordering Guide

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

ER-1 Emergency Response System INSTALLATION & PROGRAMMING GUIDE

Preliminary. Dual-line FLOW rate/totalizers. Pr ovu Model PD6200 Analog Input. Pr ovu Model PD6300 Pulse Input. Analog Inputs.

Controller Automation, Model II+

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

CO2 Alarm. Operation. Application

Copyrights 2010 Victron Energy B.V. All Rights Reserved

Technical Specifications: The specifications represent a particular hardware platform. Application-specific software is provided.

Carbon Monoxide (CO) Gas Detection and Control System

TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date Rev.

INSTALLATION/PROGRAMMING INSTRUCTIONS E4KP ENTRYCHECK

Operating ambient temperature range: 5ºC to 50ºC Storage temperature range: -30ºC to 70ºC

INSTALLATION INSTRUCTIONS

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Life Alarm Fire Alarm Controls

PROXIMITY CARD READERS C-10, C-20, C60, C70

Energy Depot GmbH PRODUCT AND APPLICATION GUIDE. Total Monitoring Solution for PV. Delivering Solutions for Energy Management

Application/Connection Examples

Intelligent RS-485 I/O expansion unit: RU-87Pn Series

Touchpoint Pro. Flexible Gas Control System

Temperature & Humidity SMS Alert Controller

DTW Works Master Specification Version 2006

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

Ammonia Detection System Codes and Design Specifications

500r+ Installation and User Guide

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

HSG Engineering Tech Bulletin

SECTION NOx, CO AND NATURAL GAS DETECTION, MONITORING AND ALARM CONTROL SYSTEMS

NL708 (XWA11V) Walk-In Temp / Door /Alarm / Light Module

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

DREXELBROOK. USonic-R Series. Ultrasonic Level Measurement System. User Friendly

Short information Parameters are programmed via front-side membrane keypad

PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS

EBS852 (Contrac) Power Electronic Unit

Infrastructure Management & Monitoring For Business-Critical Continuity. Liebert AC4. User Manual

Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual

920 Series. Dual-point heat-tracing control system. Product overview. 920*E4FWL*SIS302*SS3102 shown

Control Panels D9412GV3/D7412GV3/D7212GV3. UL Installation Instructions

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110

Procidia Control Solutions Dedicated Backup in a Single Variable Control Loop

How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power)

ZC-24DO CANopen I/O Module: 24 Digital Outputs

Contents. : AEOS Blue cabling and technical aspects. NEDAP N.V. IDEAS Information Bulletin No: H032. Date : 12 January 2016

ENGINEERING SPECIFICATIONS SENSAPHONE IMS-4000

FLARE MONITORS FLARE MONITOR (FM) PILOT MONITOR (PM) FLAME INTENSITY (FI)

MechoNet TM Network Interface (MNI) Specification Submittal

INTERFACING SECURITY SYSTEMS TO HOMEVISION

Section TELEPHONE AUTOMATIC DIALER SYSTEM

Fire Fighter Phone System Installation Instructions

ACS-30-EU-EMDR-10-MOD

Transcription:

Multipoint Scanning Alarm System Many gas detection applications require multiple sensing locations to provide adequate area protection for plant personnel. Signals from a variety of field measurement sites are often transmitted to a central location where display and alarming functions are needed. ATI's Series l4 Scan Alarm) Receiver provides a versatile central monitor that can be configured to meet most multipoint gas detection applications. Features Monitors up to 16 analog 4-20 ma inputs from remote transmitters. Provides 24 VD power for up to 16 looppowered toxic gas transmitters or 12 3-wire combustible gas transmitters. Two line alphanumeric LD provides sequential display of each channel and the alarm status for that channel. Display locks on any channel that goes into alarm. Remote alarm reset input. Two programmable alarm setpoints for each analog input plus a trouble alarm for each channel. Six assignable SPDT alarm relays in standard configuration, with expansion for up to 36 total relay outputs. One output relay is factory set for global alarm and one is set for system failure. Battery backup module available to operate the system for up to 30 minutes with the maximum number of combustible gas transmitter inputs (worst case). Standard RS-232/485 serial interface allows all configurations to be set up by computer and alarm events to be automatically monitored by computer. Up to 32 separate monitors can be connected to a single RS-485 communication link. Standard NEMA 4X wall mount enclosure. Optional panel mount configuration.

Multipoint Scanning Alarm System

Series 14 ScanAlarm - General Arrangement Diagram SYSTEM DIAGRAM SERIES 14 ScanAlarm POWER 85-255 VA, 50/60Hz OR 12VD RS232/RS485 RELAY OUTPUTS BATTERY BAKUP MAX. 28 EXTERNAL RELAYS MAXIMUM 16 INPUTS (2 OR 3 ONDUTOR ABLE FOR EAH INPUT) INPUTS MAY BE LOOP-POWERED 4-20mA OR POWERED 4-20mA (SEE PAGE 5&6) OTHER MFG'S TRANSMITTER SERIES B12 2-WIRE TRANSMITTER MODEL B12-17 OMBUSTIBLE GAS TRANSMITTER MODEL A12 UniSens 2-WIRE TRANSMITTER SS-14RA.PM5, DATE: 7/25/97, DRAWN: A.W., APPD: ATI-0261 Page 1 of 10

Series 14 ScanAlarm - Dimensional Diagrams WALL MOUNT VERSION - ENLOSURE DIMENSIONS HINGE HINGE 10.0" 254 mm 9.48" 241 mm 6.68" 170 mm (20) Pg 16 KKOUTS **6.50" 165 mm 7.1" 180 mm (4) Pg 21/29 KKOUTS **.60" 15 mm 21.31" 541 mm **13.62" 346 mm ** MOUNTING DIMENSIONS **9.72" FRONT VIEW 239 mm SIDE VIEW 4.37" 111 mm TES ATI-0247 BOTTOM VIEW (2) Pg 16/21 KKOUTS PANEL MOUNT VERSION - FRONT PANEL STAK 1) Enclosure Ratings: Nema-4X/IP 65 2) Enclosure Material: Polystyrene base and cover, hinged transparent door with push-release latch. 3) Knockouts: Pg 16 (.90" dia.) Pg 21 (1.15" dia.) Pg 29 (1.50" dia.) GLOBAL ALARM A SYSTEM FAULT B A FAIL 1 2 3 4 ATI-0255 Page 2 of 10

Series 14 ScanAlarm - Dimensional Diagrams - Panel Mount Version PANEL UTOUT - FRONT PANEL STAK 9.14" 232 mm 4.57" 116 mm 8.94" 227 mm 4.47" 114 mm (6).166" DIA. UTOUT 3.43"O.. 87 mm 3.08"O.. 78 mm ATI-0254 POWER SUPPLY / I/O PB ON SUB-PANEL 13.0" 330 mm 11.24" 286 mm TE: THIS ASSEMBLY IS SUPPLIED. (4) 3/8" DIA. MOUNTING HOLES HARDWARE IS USTOMER SUPPLIED 21.0" 533 mm 19.24" 489 mm ATI-0257 Page 3 of 10

Series 14 ScanAlarm - System Wiring GENERAL USTOMER ONNETIONS ATI-0248 Page 4 of 10

Series 14 ScanAlarm - System Wiring A12 UniSens 2-WIRE TRANSMITTER INTERONNETIONS 14 ScanAlarm I/O PB TB5 HANNEL 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 +24 SIG GND DRAIN OR SHIELD IF USED TB1 SHIELD 2 OND. 20 AWG UNSHIELDED OR SHIELDED ABLE, 5000 FT. MAX ( POLARITY REQUIREMENT) EARTH GROUND (OR ONDUIT) LOOP POWER STOP DRAIN AT ASE WALL (IF USED), DO T EXTEND DRAIN OR SHIELD INTO ASE WALL GND TERMINAL LOATED NEXT TO RELAY BASE GROUND TERMINAL SENSING MODULE AUTO-TEST OPTION ATI-0256 SERIES B12 2-WIRE TRANSMITTER INTERONNETIONS 14 ScanAlarm I/O PB TB5 HANNEL 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 +24 SIG GND DRAIN OR SHIELD IF USED TB1 SHIELD B12 SENSOR/TRANSMITTER (TYP. WIRING OF 2-WIRE LOOP POWERED INPUT) 2 OND. 20 AWG UNSHIELDED OR SHIELDED ABLE, 5000 FT. MAX ( POLARITY REQUIREMENT) STOP DRAIN AT ASE WALL (IF USED), DO T EXTEND DRAIN OR SHIELD INTO ASE WALL REEIVER ONNETION ( POLARITY REQUIREMENT) ATI-0249 Page 5 of 10

Series 14 ScanAlarm - System Wiring B12-17 OMBUSTIBLE TRANSMITTER INTERONNETIONS 14 ScanAlarm I/O PB SHIELD POWERED 4-20mA INPUT TRANSMITTER INTERONNETIONS TB5 TB5 HANNEL 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 +24 SIG TB1 GND DRAIN OR SHIELD IF USED 3 OND. SHIELDED ABLE B12-17 OMBUSTIBLE GAS SENSOR/TRANSMITTER (TYP. WIRING OF 3-WIRE INPUT) OMBUSTIBLE SENSOR ATI-0251 14 ScanAlarm I/O PB HANNEL 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 +24 SIG GND TB1 SHIELD DRAIN OR SHIELD IF USED 2 OND. 20 AWG UNSHIELDED OR SHIELDED POWERED 4-20mA OUTPUT TRANSMITTER (SUPPLIED BY OTHERS) ATI-0250 Page 6 of 10

Series 14 ScanAlarm - Relay Module Option 2 RELAY MODULE, ENLOSURE DIMENSIONS FRONT VIEW SIDE VIEW 7.09" 180 mm 6.50" 165 mm MOUNTING DIMENSIONS 10.0" 254 mm 4.37" 111 mm TES 80-0040R 9.41" 239 mm MOUNTING DIMENSIONS BOTTOM VIEW KKOUTS 1) Enclosure Ratings: Nema-4X/IP 65 2) Enclosure Material: Polystyrene base and cover 3) Knockouts: Pg 16 (.90" dia.) Pg 21 (1.15" dia.) Pg 29 (1.50" dia.) 4) Enclosure may be close coupled to ScanAlarm enclosure using bulkhead fit ting supplied with relay module enclosure. Page 7 of 10

Series 14 ScanAlarm - Relay Module Option 4 RELAY MODULE, ENLOSURE DIMENSIONS FRONT VIEW SIDE VIEW 14.21" 361 mm 13.62" 346 mm MOUNTING DIMENSIONS 9.72" 239 mm MOUNTING DIMENSIONS 4.37" 111 mm 10.0" 254 mm KKOUTS 80-0036R BOTTOM VIEW TES 1) Enclosure Ratings: Nema-4X/IP 65 2) Enclosure Material: Polystyrene base and cover 3) Knockouts: Pg 16 (.90" dia.) Pg 21 (1.15" dia.) Pg 29 (1.50" dia.) 4) Enclosure may be close coupled to ScanAlarm enclosure using bulkhead fit ting supplied with relay module enclo sure. Page 8 of 10

Series 14 ScanAlarm - Relay Module Option ScanAlarm / RELAY MODULE WIRING DIAGRAM ATI-0271 Page 9 of 10

Series 14 ScanAlarm - Relay Module Option RELAY MODULE WIRING DIAGRAM 8 RELAY EXPANSION MODULE N TB1 N TB2 N TO DESIRED I/O PB TB4 (-) TERMINAL TO ANY I/O PB TB4 (+) TERMINAL 1 2 3 4 5 6 7 8 + TB9 N N TB3 TB4 TB5 N TB6 N TB7 N TB8 ATI-0273 Page 10 of 10