Unidirectional Transmitter/ Receiver Units Introduction
|
|
|
- Leo Doyle
- 10 years ago
- Views:
Transcription
1 Unidirectional Transmitter/ Receiver Units Introduction Wireless Input/Output (I/O) connects directly to analog, discrete and pulse transducer signals. The signals are transmitted by radio and either re-created as output signals, or output via serial link or field-bus. Weidmuller units have the ability to form sophisticated peer-to-peer networks, with event-reporting messaging to optimize wireless density. Weidmuller products are designed for high reliability operation on open licensefree radio bands. WI-I/O 9-L Unidirectional Transmitter/Receiver Units The Unidirectional range of products is suitable for connecting to a single sensor or group of sensors and provides an economical solution for remote monitoring systems. The Unidirectional L products can also be used in more complex networks as signal transmitters or receivers. Frequency hopping spread spectrum MHz license-free USA/Canada/Mexico Configurable sub-bands license-free South America, Australia/NZ, Asia, Europe Applications Wireless connection of flowmeters or energy meters Monitoring storage tanks Monitoring cathodic protection on pipelines Wireless alarms from power reticulation fault relays Transmitter unit Input-only transmitter unit - two digital/pulse inputs, one analog input and one thermocouple mv input Transmits to Receiver unit as a matched pair where the input signals are re-created as output signals, or can transmit to a Multi-I/O or Gateway unit Class 1 Div 2 hazardous areas approval C US Up to 3000 wireless units per network External inputs plus internally calculated values - analog setpoint status, pulse count, power supply voltage input 20 to +100mV with cold-junction compensation and linearization for J, K or T-type Setpoints status generated by comparing analog input to high and low setpoints inputs can also be used as pulse count inputs Power supply 9 30VDC, measured and available as a transmitted variable 24VDC analog loop supply internally provided RS232 Configuration port Features Matched transmitter/receiver pair of modules, or individual transmitter and receiver units Peer-to-peer communications. Exception reporting. Reliable self-checking messages. Highly secure data encryption. Multi-hop repeater functions - up to 5 intermediate units can be configured in any input-output link Factory configured as a matched Transmitter/Receiver pair or user-configurable with E-Series Windows configuration program 16
2 Receiver unit Output-only receiver unit - three digital contact outputs and one analog output Receives radio commands from Transmitter unit as a matched pair where the input signals are re-created as output signals, or can receive commands from a Multi-I/O or Gateway unit Class 1 Div 2 hazardous areas approval C US Up to 3000 wireless units per network Power supply 9 30VDC; 24VDC analog loop supply internally provided Communications failure indication and configurable output Outputs can be configured as retained or reset (fail-safe) on communications failure LED indication of radio signal strength RS232 Configuration port Transmitter/Receiver Unit Ordering Information Unit Description WI-I/O 9-L-T Wireless Transmitter (900 MHz) WI-I/O 9-L-R Wireless Receiver (900 MHz) WI-I/O 9-L-P1 900 MHz Wireless Transmitter/ Receiver Pair with two -2 db Dipole Antennas WI-I/O 9-L-P2 900 MHz Wireless Transmitter/ Receiver Pair with two 0 db Dipole Antennas Dimensions WI-I/O 9-L-T OK D1 D2 SP TX AZ SET PG 3.9" (100 mm) 4.7" (120 mm).09" (23 mm) General Frequency: frequency hopping spread spectrum, Sensitivity: line-of-sight range 20 miles (4W ERP - effective radiated power ), 15km ( ERP); 3000 ft /1000 m in obstructed industrial environments; radio transceiver or gateway units Antenna Connector: SMA connector for antenna or coaxial cable connection Temperature: -40 to 60 C / -40 to 140 F Humidity: Regulatory Approvals: EMC compliant 89/336 EEC, EN , AS3548, FCC Part 15, Approved to FCC Part , RS210 Housing: DIN-rail thermo-plastic enclosure 100 x 22 x 120 mm / 3.9 x 0.9 x 4.7 inches Transmitter Unit: Power/OK, radio TX, DIN1, DIN2, analog set-point status Receiver Unit: Power/OK, radio RX, DO1, DO2, DO3, communications fail LEDs also used to provide radio signal strength indication Input Source Function external status Pulse Total external count external analog external analog Set Point internal status Supply Voltage internal analog Input values transmitted as per WIB-net (see page 8) protocol - exceptionreporting on signal change, and update time. Up to 5 repeater addresses, configurable. 17
3 / Pulse Inputs Two inputs, suitable for voltage-free contacts / NPN, or voltage input 0-1 VDC on / >3 VDC off pulse input max. rate 10 Hz, 50 msec on time. Pulse counted as 16-bit register. Inputs Floating differential input, 16-bit, Inputs Millivolt (-20mV to +100mV), J, K, or T type linearization Accuracy better than 1 C RS232 RJ45 female DCE, used for configuration LED Indication Transmitter Unit Power/OK, radio TX, DIN1, DIN2, analog set-point status Receiver Unit Power/OK, radio RX, DO1, DO2, DO3, communications fail LEDs also used to provide radio signal strength indication Normal Supply: 9-30 VDC, power - receiver normal 70mA, max. 250mA Transmitter normal 70mA, transmitting max. 600mA loop supply internally generated, 24VDC 35mA Internal monitoring of supply voltage may be transmitted as an input (transmitter unit only) Set-point Status High and low set-points generate internal digital statusset-point status sets (on) when analog value < low setpoint and resets (off) when analog value > high set-point. Status is transmitted as per digital input, set-point values are set via the front panel rotary switch or configuration software. Separate set-points for (4-20 ma), thermocouple and supply inputs are configurable Receiver Outputs Outputs Three relay contact outputs, 260V 1A Outputs, source output, 12-bit, 0.1% Communication Failure Internal status based on configurable time-out value Comms-fail status can be configured to a local output Fail-Safe On comms-fail, outputs user-configurable as retained last correct value or reset (fail-safe) Configuration and Diagnostics Factory configuration transmitter/receiver matched pair, AI to AO, 2DI to 2DO, SP status to DO3 via RS232 - RJ45 cable User configuration via serial port. Unidirectional units can be configured to network with multi-i/o and gateway units. Diagnostics features: read input values, write output messages 18
4 Unidirectional Transmitter/Receiver Units 900 MHz WI-I/O 9-L-T Transmitter WI-I/O 9-L-R Receiver C C1D2 US Technical Data Pulse floating differential input: Accuracy Receiver Outputs Comms-Fail Fail-safe Power loop supply internally generated Internal monitoring of supply low voltage status Power consumption increases for pulse inputs > 10Hz. General Data Operating Temperature Humidity EMC Standards Mounting LED indication: Transmitter Unit LED indication: Receiver Unit frequency hopping spread spectrum Transmit power Maximum line of sight range Antenna connector Dimensions mm (in) Configuration Diagnostics Ordering Data Accessories: DB9 Female-RJ45 Serial configuration cable two inputs, suitable for voltage free contacts / NPN, or voltage input 0-1 VDC on / >3 VDC off max rate 10 Hz, 50 msec on time. Pulse counted as register. Receiver 100mA, Transmitter 40mA quiescent, during radio transmission (50 msec) 300mA RS232 RJ45 female DCE, used for configuration Power/OK, Radio TX, DIN1, DIN2, Setpoint status 20 miles (4W ERP), 15km ( ERP); 3000 ft / 1000 m in obstructed industrial environments. Radio repeater units. Each transmission may be configured to be sent 1 to 5 times. User configuration via serial port. Unidirectional units can be configured to network with Multi-I/O and Gateway units. Diagnostics features - read input values, write output messages. WI-I/O 9-L-T WI-CSER-RJ Receiver 100mA, Transmitter 40mA quiescent, during radio transmission (50 msec) 300mA RS232 RJ45 female DCE, used for configuration Power/OK, Radio RX, DO1, DO2, DO3, Communications Fail. 20 miles (4W ERP), 15km ( ERP); 3000 ft / 1000 m in obstructed industrial environments. Radio repeater units. Each transmission may be configured to be sent 1 to 5 times. User configuration via serial port. Unidirectional units can be configured to network with Multi-I/O and Gateway units. Diagnostics features - read input values, write output messages. WI-I/O 9-L-R WI-CSER-RJ
5 Unidirectional Transmitter/Receiver Units 900 MHz WI-I/O 9-L-P1 Set - 1 Transmitter, 1 Receiver WI-I/O 9-L-P2 Set with 2 WI-ANT-DPL-0-8 C C1D2 US Technical Data Pulse floating differential input: Accuracy Receiver Outputs Comms-Fail Fail-safe Power loop supply internally generated Internal monitoring of supply low voltage status Power consumption increases for pulse inputs > 10Hz. General Data Operating Temperature Humidity EMC Standards Mounting LED indication: Transmitter Unit LED indication: Receiver Unit frequency hopping spread spectrum Transmit power Maximum line of sight range Antenna connector Dimensions mm (in) Configuration Diagnostics Ordering Data Kit Contents 20 two inputs, suitable for voltage free contacts / NPN, or voltage input 0-1 VDC on / >3 VDC off max rate 10 Hz, 50 msec on time. Pulse counted as16 bit register. Receiver 100mA, Transmitter 40mA quiescent, during radio transmission (50 msec) 300mA RS232 RJ45 female DCE, used for configuration Power/OK, Radio TX, DIN1, DIN2, Setpoint status Power/OK, Radio RX, DO1, DO2, DO3, Communications Fail. 20 miles (4W ERP), 15km ( ERP); 3000 ft / 1000 m in obstructed industrial environments.radio distances can be increased by up to 5 intermediate repeater units. Each transmission may be configured to be sent 1 to 5 times. Factory configuration transmitter/receiver matched pair, AI to AO, 2DI to 2DO, SP status to DO3. User configuration via serial port. Unidirectional units can be configured to network with Multi-I/O and Gateway units. Diagnostics features - read input values, write output values, radio signal strength, monitor communication messages. WI-I/O 9-L-P Two -2 db Dipole antennas ( ) Two 3 ft. antenna connecting cables/brackets One configuration cable two inputs, suitable for voltage free contacts / NPN, or voltage input 0-1 VDC on / >3 VDC off max rate 10 Hz, 50 msec on time. Pulse counted as16 bit register. Receiver 100mA, Transmitter 40mA quiescent, during radio transmission (50 msec) 300mA RS232 RJ45 female DCE, used for configuration Power/OK, Radio TX, DIN1, DIN2, Setpoint status Power/OK, Radio RX, DO1, DO2, DO3, Communications Fail. LEDs also used to provide radio signal strength indication 20 miles (4W ERP), 15km ( ERP); 3000 ft / 1000 m in obstructed industrial environments. Radio distances can be increased by up to 5 intermediate repeater units. Each transmission may be configured to be sent 1 to 5 times. Factory configuration transmitter/receiver matched pair, AI to AO, 2DI to 2DO, SP status to DO3. User configuration via serial port. Unidirectional units can be configured to network with Multi-I/O and Gateway units. Diagnostics features - read input values, write output values, radio signal strength, monitor communication messages. WI-I/O 9-L-P Two 0 db Dipole antennas ( ) Two 15 ft. antenna connecting cables/brackets One configuration cable
Wireless Connectivity Solutions
CATALOG 12 Wireless Connectivity Solutions Product Catalog Contents Product Overview Introduction...3 Application Examples...6 Wireless I/O Unidirectional Transmitter/Receiver Units Introduction...16 Product
Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION
Modular, Customizable Wire Replacement 128 / 256 Bit AES Encryption Software Selectable RF Transmit Power Software Selectable Over-the-air Data Rate Modbus ASCII /RTU Compatible Wide Operating Temperature
Electronic Control Devices The European Product Catalogue 2007
FX14 Field Controller (1/4) FX14 Field Controller The FX14 is an equipment field controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating,
Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers
Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers Analog Data Links Multi-Channel Contact Closures Multiplexers Digital Data Links - Contact Closures Power Supply
Telephone- and leased line modem for industrial applications TD-36
Telephone- and leased line modem for industrial applications TD-36 Modem for industrial PSTN- and leased line applications The TD-36 is an analogue V.34 PSTN modem as well as an industrial 2-wire leased
Electronic Control Devices The European Product Catalogue 2007
FX07 Field Controller (1/4) FX07 Field Controller Display Model Dimensions in mm (inches) The FX07 is a terminal unit controller in the Facility Explorer range of products. The controller is designed specifically
Rack mounted telephone- and leased line modem for industrial applications
Rack mounted telephone- and leased line modem for industrial applications TR-6 Rack modem for industrial PSTNand /-wire leased line applications The TR-6 is an analogue V. 9 -rack PSTN modem as well as
JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
WIRELESS REMOTE MONITORING OF CATHODIC PROTECTION SYSTEMS. John Hawkyard MICorr Deputy General Manager Rawabi Corrosion Technology Co Ltd Al-Khobar
WIRELESS REMOTE MONITORING OF CATHODIC PROTECTION SYSTEMS John Hawkyard MICorr Deputy General Manager Rawabi Corrosion Technology Co Ltd Al-Khobar INTRODUCTION Cathodic Protection is an electrochemical
SR450 RECEIVER OPERATING INSTRUCTIONS 1892 1128
SR450 RECEIVER OPERATING INSTRUCTIONS 1892 1128 These operating instructions are intended to provide the user with sufficient information to install and operate the module correctly. The Wood & Douglas
Quick Connect. quick - simple - efficient. www.g-mw.de
Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power
Regards from the Team at Rheology Solutions.
Rheology Solutions is the sole Australian distributor of this product range and we welcome the opportunity of discussing your application requirements. We hope the information you are seeking is contained
Bluetooth to Serial Adapter
Bluetooth to Serial Adapter Third Edition, Oct 2007 Version 3.0 771-BTS1009C3-001 Contents 1.0 Features....P.2 2.0 Package Content....P.2 3.0 Hard Drives Requirement.P.2 4.0 Specifications.P.3 5.0 Pin
5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual
5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual Content Overview... 1 Introduction... 1 Features... 3 Packing List... 4 Safety Precaution... 4 Hardware Description... 5 Front Panel...
WIRELESS INSTRUMENTATION TECHNOLOGY
BS&B WIRELESS, L.L.C. BS&B WIRELESS, L.L.C. WIRELESS INSTRUMENTATION TECHNOLOGY Printed February 2004 BS&B WIRELESS, L.L.C. 7422-B East 46th Place, Tulsa, OK74145 Phone: 918-622-5950 Fax: 918-665-3904
M2M I/O Modules. To view all of Advantech s M2M I/O Modules, please visit www.advantech.com/products.
M2M I/O Modules 14 M2M I/O Modules Overview 14-2 M2M I/O Modules Selection Guide 14-6 ADAM-2510Z Wireless Router Node 14-8 ADAM-2520Z Wireless Modbus RTU Gateway 14-9 ADAM-2031Z ADAM-2632Z ADAM-2017Z ADAM-2018Z
EZmoto V2. Product description Rev. 6 10/01/2014. EZmoto V2 Product description Rev.6 10/01/2014
EZmoto V2 Product description Rev. 6 10/01/2014 1 Contents 1. Overview... 3 2. Hardware Interface Description... 3 2.1 Main features of the EZmoto... 3 2.2 Hardware block diagram... 4 2.3 Internal Hardware
3500/22M Transient Data Interface
3500/22M Transient Data Interface Bently Nevada* Asset Condition Monitoring Description The 3500 Transient Data Interface (TDI) is the interface between the 3500 monitoring system and GE s System 1* machinery
IntesisBox Modbus Server Fidelio IP
IntesisBox Server Fidelio IP Gateway for integration of Micros Fidelio Ho management system into (RTU and TCP) enabled control systems. Integrate your Micros Fidelio Ho management system into your master
FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology
FOSTCDR pn 8684R1 FOSTCDR-0812ds page 1/5 Industrial Serial to Multimode Fiber Optic Converter Data Rates up to 115.2 kbps 2.5 Mile (4 km) Range 10 to 30 VDC Input Voltage Wide Operating Temperature 2000V
Model: DC-A2IO Advanced HVAC Controller
Model: DC-A2IO Advanced HVAC Controller Job Name: Schedule Reference: Date: DC-A2IO Advanced HVAC Controller Package PAC-IF01 M-Net Adapter AL2-14MR-D α2 Simple Application Controller Accessories AL2-2DA
FOM-5A, 6A. Asynchronous Fiber Optic Modem
FOM-5A, 6A Asynchronous Fiber Optic Modem FEATURES Asynchronous transmission at up to 19.2 kbps Transmission range up to 3 km (1.8 mi), regardless of data rate Full- or half-duplex Transfers one control
IntesisBox KNX - LON
IntesisBox KNX - Gateway for integration of devices into KNX systems. Integrate Air Conditioning from the main manufacturers (DAIKIN, Mitsubishi Electric, Mitsubishi Heavy Industries, Toshiba, Fujitsu,
DREXELBROOK. USonic-R Series. Ultrasonic Level Measurement System. User Friendly
DREXELBROOK A Leader In Level Measurement Solutions USonic-R Series Ultrasonic Level Measurement System User Friendly Set the measurement range directly in inches, feet, millimeters, centimeters, or meters
Indoor / Outdoor Antenna
z300 High Precision NTP Time Server Indoor / Outdoor Antenna High Precision NTP Time Server with PoE (Indoor or Outdoor use) synchronized by GPS Revision 4 ZTI / 1 boulevard d'armor / BP 20254 / 22302
Automation System TROVIS 6400 TROVIS 6493 Compact Controller
Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general
IntesisBox KNX Modbus TCP master
IntesisBox KNX TCP master Gateway for integration of TCP slave devices into KNX control systems. Integrate any TCP slave device into KNX. KNX TCP slave EIB Bus IntesisBox Ethernet slave LinkBoxEIB Configuration
LDG DTS-4/4R Desktop Coaxial Switch / Remote
LDG DTS-4/4R Desktop Coaxial Switch / Remote LDG Electronics 1445 Parran Road, PO Box 48 St. Leonard MD 20685-2903 USA Phone: 410-586-2177 Fax: 410-586-8475 [email protected] www.ldgelectronics.com
LevelOne IFE-0500 4-Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual
LevelOne IFE-0500 4-Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual Ver. 1.0.0-0711 1 FCC Warning This Equipment has been tested and found to comply with the limits for a Class-A digital
Intelligent RS-485 I/O expansion unit: RU-87Pn Series
INTRODUCTION RU-87Pn series is a remote intelligent I/O expansion unit that used to expand i-87k series I/O modules over the RS-485 for industrial monitoring and controlling applications. There are more
Loop-O9310 4E1 or 4T1 Fiber Optical Mux
Loop-O930 E or T Fiber Optical Mux Features CPU Version Up to E or T links on one fiber Optical + protection 0/00 BaseT Ethernet Bridge mode, maximum transmission bandwidth 22Mbps (optional) One V.35,
Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter
ICS-2 S15 Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter Cost Effective Solution for RS-232 / RS-422 / RS-485 to Industrial Ethernet Application PLANET ICS-210x series Smart Media Converter
KNX Panasonic Air Conditioners
IntesisBox KNX Panasonic Air Conditioners Gateway for Panasonic ECOi and PACi system integration into KNX networks Up to 30 Outdoor units Up to 64 Indoor units PA-AC-KNX-64/128 EIA485 U1U2 line U1U2 line
Waveguide Access Point WGA631. Product Guide
Waveguide Access Point Product Guide Waveguide Access Point Contents 1. Description............................ 3 2. Application............................ 3 3. Technical data... 4 4. Physical interfaces......................
IntesisBox KNX Modbus RTU master
IntesisBox KNX RTU master Gateway for integration of RTU devices into KNX control systems. Integrate RTU devices (Chillers, Roof Tops, electricity meters, heating floors, heat pumps, PLCs ) into KNX control
L-LAS-TB-CL serie. laser light curtains for inline measuring tasks
L-LAS-TB-CL serie laser light curtains for inline measuring tasks Maximum distance 2.000 mm Measurement range 6 up to 98 mm Resolution up to 4 µm up to 1,5 khz scan rate 0-10 V or 4-20 ma analogue output
Loop-O9310 4E1 or 4T1 Fiber Optical Mux
Loop-O930 E or T Fiber Optical Mux Features Up to E or T links on one fiber Optical + protection 0/00 BaseT Ethernet Bridge mode, maximum transmission bandwidth 22Mbps (optional) One V.35, X.2, RS9/V.36,
ABB RTU560A Series CMU & Modules
ABB RTU560A Series CMU & Modules 1KGT 150 648 V1.02 March 4, 2012 Slide 1 Contents RTU560A rack solutions March 4, 2012 Slide 2 560CSR01 Available for wall mounting and swing frame Supports redundant power
How To Use A Ds340 (Dsp)
Ideal for monitoring dust levels in the exhaust gas of industrial combustion or air filtration processes. Innovative Dynamic Detection Principle (DDP) measurement technique Immune to gradual reductions
O C M III. Open Channel Flow Monitor
O C M III Open Channel Flow Monitor Part 1. General 1.1 Scope A. This section describes the requirements for an ultrasonic flow transmitter with sensor and temperature compensation probe. B. Under this
RTM X42 Multi-Channel Radio Transmission Tension Monitoring and Control System
RTM X42 Multi-Channel Radio Transmission Tension Monitoring and Control System RTM X42 is an innovative system that utilizes force measuring rollers to capture the tension of individual wires or strands,
GSM Voice Auto Dialer & SMS Sender JC-999
GSM Voice Auto Dialer & SMS Sender JC-999 Main features: () Large LCD display,integrated integrated keypad, human-friendly programming; (2) Support 2 alarm receiving numbers; (3) Triggering means: N.C
THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES
TSI and TSI logo are registered trademarks of TSI Incorporated. SmartTune is a trademark of TSI Incorporated. THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES IFA 300 Constant Temperature Anemometry
Microcor Wireless Transmitter (MWT)
Rohrback Cosasco Systems, Inc. Microcor Wireless Transmitter (MWT) Features: Highly Secure and Reliable Self Organizing Wireless Mesh Network High Resolution Metal Loss Measurement for all process environments
User manual Compact Web PLC WP240 series IEC-line
User manual Compact Web PLC WP240 series IEC-line update: 09-01-2014 IEC-line by OVERDIGIT overdigit.com 1. General description The WP240 device is a PLC, programmable in IEC61131-3 language using CoDeSys
Product Information S N O. Portable VIP protection CCTV & Alarm System 2
Product Information S N O Portable VIP protection CCTV & Alarm System 2 G O V E R N M E N T A L S E C U R I T Y S O L U T I VIP KIT Rapid Deployment VIP Protection Kit The VIP KIT has been designed to
SIMATIC S7-1200. It s the Interplay that makes the difference. Siemens AG 2010. All Rights Reserved.
SIMATIC S7-1200 It s the Interplay that makes the difference SIMATIC S7-1200 Controller SIMATIC S7-1200 CPUs CPU 1211C 3 configurations per CPU Dimensions W x H x D (mm) CPU 1212C CPU 1214C DC/DC/DC, AC/DC/RLY,
DPI 260 SERIES: Digital Pressure Indicators
DPI 260 SERIES: Digital Pressure Indicators INTRODUCTION The DPI 260, 261 and 262 range of digital pressure instruments measure and indicate pressure in any specified scale units and provide accuracies
How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)
transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control
RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits
RHE12 Hazardous Area Coriolis Mass Flow Transmitter Features Field mounting Compact, pressure safe housing ATEX and CSA approvals for installation in hazardous areas 24 VDC power supply Configurable analog
PRO 5000 CPE 1D Quick Installation Guide
PRO 5000 CPE 1D Quick Installation Guide Introduction This Quick Installation Guide covers the basic installation of the PRO 5000 CPE. For more information, refer to the relevant sections in the Product
IntesisBox KNX LG Air Conditioning
IntesisBox KNX LG Air Conditioning Gateway for integration of LG Air Conditioners with KNX control systems. 1. Main Features Direct connection to KNX TP-1 (EIB) bus. Direct connection to LG outdoor unit
XPress-Pro SW Series Hardened Ethernet Switches Enabling Communication for the Demanding Industrial Environment
XPress-Pro SW Series Hardened Ethernet Switches Enabling Communication for the Demanding Industrial Environment Part of the device networking family of networkenablement products, XPress-Pro SW series
BROADCAST Trasmettitori / Transmitters DBH3 GAP FILLER
INTRODUCTION The equipment described here below is a TRANSMITTER that allows to receive a signal coming from satellite, to demodulate it to have the ASI format, to present it into DVB-H standard by a DVB-H
Product Specifications
Cisco Model EPR2320 EuroDOCSIS 2.0 Residential Gateway with Wireless Access Point The Cisco Model EPR2320 EuroDOCSIS 2.0 Residential Gateway (EPR2320) combines a cable modem, router, and wireless access
Application. Characteristics RTU560. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11
Communication Unit 560CMD11 The SLC works as master for the RTU560 serial peripheral bus (I/O-Interface/ Wired-OR-Bus ). The MPU is responsible for the other tasks. The MPU handles the absolute time and
Loop-O9310 4E1 or 4T1 Fiber Optical Mux
Loop- E or T Fiber Optical Mux Description Features CPU Version Non-CPU Version Up to E or T links on one fiber Optical + protection 0/00 BaseT Ethernet Bridge mode, maximum transmission bandwidth 22Mbps
Technical Specifications: The specifications represent a particular hardware platform. Application-specific software is provided.
Preliminary TECHNICAL DATASHEET #TDAX020700 HYDRAULIC VALVE CONTROLLER 24 I/O 5 Analog and 6 Digital Inputs 1 Temperature Sensor and 1 RPM Sensor Interface 2 PWM Inputs 6 Proportional and 4 ON/OFF Current
Loop-IP6702 TDMoEthernet
Loop-IP6702 TDMoEthernet Description: Loop-IP-6702 device allows operator to transport 1 or 2 E1/T1* with timing and Ethernet traffic over IP network. This allows cost effective migration to IP network
TDMoEthernet. Description
Loop-IP6700 TDMoEthernet Description Loop-IP6700 TDMoEthernet is used to transport TDM traffic over IP network, in addition to Ethernet traffic. As the core communications network migrates from TDM to
How To Use A Sound Card With A Subsonic Sound Card
!"## $#!%!"# &"#' ( "#' )*! #+ #,# "##!$ -+./0 1" 1! 2"# # -&1!"#" (2345-&1 #$6.7 -&89$## ' 6! #* #!"#" +" 1##6$ "#+# #-& :1# # $ #$#;1)+#1#+
www.kem-kueppers.com [email protected] Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters
www.kem-kueppers.com [email protected] Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters Description The Tricor Mass Flow Meters measure simultaneously mass
Integrating Digiquartz MET3 and MET3A Broadband Meteorological Systems with Leica GX1200 Series GPS Receivers
Integrating Digiquartz MET3 and MET3A Broadband Meteorological Systems with Leica GX1200 Series GPS Receivers The standard by which other standards are measured Paroscientific, Inc. 4500 148 th Ave. N.E.
Wireless Solutions for Environmental Monitoring and Process
Wireless Solutions for Environmental Monitoring and Process Solutions for Waste Management Landfill Leachate removal from a landfill well is a primary requirement. Although different types of pumps are
FX07 Field Controller
Product Bulletin FX07 Field Controller Issue Date March 25, 2008 FX07 Field Controller The FX07 is a high performance field controller designed specifically for commercial Heating, Ventilating, Air Conditioning,
Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D
7000/7000C/7020 Multi-instrument 4921210109D Features Measurements All 3-phase AC measurements True RMS Replaces analogue meters Demand on each phase current Accuracy U, I and F class 0.5 Other values
Rosemount 333 HART Tri-Loop
Product Data Sheet Rosemount 333 Rosemount 333 HART Tri-Loop HART-TO-ANALOG SIGNAL CONVERTER Convert a digital HART signal into three additional analog signals Easy to configure and install Accessory product
LED red (-): Measuring value < lower tolerance threshold LED red (+): Measuring value > upper tolerance threshold. Page 1/6
L-LAS Series L-LAS-LT-165-CL - Line laser 1 mw, laser class 2 - Visible laser line (red light 670 nm), typ. 2 mm x 3 mm - Reference distance approx. 165 mm - Measuring range typ. 65... 265 mm - Resolution
Power Supply and Indicator Unit Type 5024-1. Fig. 1 Type 5024-1. Mounting and Operating Instructions EB 9539 EN
Power Supply and Indicator Unit Type 5024-1 Fig. 1 Type 5024-1 Mounting and Operating Instructions EB 9539 EN Edition October 2003 Application 1 Application The Type 5024-1 Power Supply and Indicator Unit
IntesisBox. KNX SAMSUNG Air Conditioning. Gateway for integration of Samsung air conditioners into KNX control systems. RS485.
IntesisBox KNX SAMSUNG Air Conditioning Gateway for integration of Samsung air conditioners into KNX control systems. Integrate Samsung Air Conditioners into KNX. KNX EIB Bus IntesisBox RS485 MIM-B13x/B04A
Rosemount 333 HART Tri-Loop
Product Data Sheet September 2014 00813-0100-4754, Rev GA Rosemount 333 HART Tri-Loop HART-to-Analog Signal Converter Convert a digital HART signal into three additional analog signals Easy to configure
Instruction Sheet ACS-101. General Description. Specifications. Amplified Broadband UHF Combiner-Splitter. Overall. Antenna Splitter.
ACS-101 Amplified Broadband UHF Combiner-Splitter General Description The ACS-101 (Antenna Combiner Splitter 10 to 1) is an amplified and filtered broadband splitter-combiner. It allows up to 10 base stations
This Antenna Basics reference guide includes basic information about antenna types, how antennas work, gain, and some installation examples.
Antenna Basics This Antenna Basics reference guide includes basic information about antenna types, how antennas work, gain, and some installation examples. What Do Antennas Do? Antennas transmit radio
Wireless Connectivity
Wireless Connectivity Flexible wireless solutions for industrial applications In today s process industries there is increasing demand for greater efficiency, higher reliability and lower cost of ownership
F2400 FOM II Series Fiber Optic Modem Technical Manual
F2400 FOM II Series Fiber Optic Modem Technical Manual T1 Revision B Copyright April 2003 VERSITRON, Inc. 83 Albe Drive / Suite C Newark, DE 19702 www.versitron.com A030430283T PROPRIETARY DATA All data
WEATHER STATION FOR SOLAR FARM MONITORING
WEATHER STATION FOR SOLAR FARM MONITORING SOLAR FARM MONITORING SYSTEM: Measures global, horizontal, & background irradiance. Measures wind speed, wind direction, ambient temperature, and relative humidity.
1701/22 FieldMonitor Management Interface Module
1701/22 FieldMonitor Management Interface Module Bently Nevada Asset Condition Monitoring Description The 1701/22 FieldMonitor Management Interface Module (FMIM) is a highlyintegrated module that provides
Long Reach PoE over Coaxial Extender Kit
Long Reach over Coaxial Extender Kit Power over Ethernet Eliminates power cabling with over coaxial Supports Power over Ethernet PSE ( Injector) Power and Ethernet data transmission of 1,000m over coaxial
Overview. 1. GPS data tracking via GSM SMS / GPRS. 2. GPS data logging in internal memory. 3. Alarm alert via GSM SMS / Dialing / GPRS
Vehicle or Personal Position Tracking Vehicle Status and Speed Tracking Auto Accident Report Global Position System (GPS) Navigation System Anti theft Alarm System Overview 1. GPS data tracking via GSM
A RF18 Remote control receiver MODULE
A RF18 Remote control receiver MODULE User Guide No part of this document may be reproduced or transmitted (in electronic or paper version, photocopy) without Adeunis RF consent. This document is subject
Turbo X. www.smartwireless.co.uk. 594 channel UHF true diversity
Turbo X 594 channel UHF true diversity The new Turbo X series from Smart Wireless is the culmination of two years of research and development into advanced wireless technology. Using sophisticated RF design
ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.
IntesisBox ModBus Server - KNX Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems. Integrate KNX based lighting control into your SCADA, BMS, PLC "talking" Modbus. Master
DTS/DRS-1000RV. Owner s Manual. DTS-1000RV: DVI/HDMI or VGA, Audio, RS-232C Transmitter Extender
DTS/DRS-1000RV Owner s Manual DTS-1000RV: DVI/HDMI or VGA, Audio, RS-232C Transmitter Extender DRS-1000RV: DVI/VGA or VGA, Audio, RS-232C Receiver Extender Dtrovision LLC 9A Bergen Turnpike Little Ferry,
TAC I/NETTM. Process Control Unit
TAC I/NETTM 7756 Process Control Unit TAC s 7756 Process Control Unit (PCU), part of the TAC I/NETTM family of products, provides direct control and monitoring of process functions from a Peer-to-Peer
TELULAR SX4E PHONECELL WITH THE 8210 SPEECH MODEM APPLICATION NOTE
TELULAR SX4E PHONECELL WITH THE 8210 SPEECH MODEM APPLICATION NOTE September 2004 Prepared by: Integrated Systems Division The Sutron Corporation 21300 Ridgetop Circle Sterling, VA 20166 Copyright 2004
IntesisBox Modbus Server SAMSUNG Air Conditioners
IntesisBox Modbus Server SAMSUNG Air Conditioners Gateway for monitoring and control of Samsung NASA compatible Air Conditioning Systems from any Modbus master device TCP or RTU (BMS, PLC, SCADA, HMI,
MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter
Thermal Mass meter and Temperature Transmitter Description The MTI10 insertion thermal mass flowmeter and the MTL10 in-line thermal mass flowmeter provide accurate mass flow measurement of clean, dry gases
Installation Instructions. Wireless Adapter/Repeater. Introduction. 30-3001-887 Rev C
/Repeater Installation Instructions 30-3001-887 Rev C Workstation Ethernet bcx Controller Repeater Repeater Introduction Schneider Electric has designed a device that allows Andover Continuum controllers
Best Practices Guide for Obvius Data Acquisition Products
Best Practices Guide for Obvius Data Acquisition Products Part I: Background/general information Obvius LLC provides industry-leading products for cost effective data gathering, storage and communications.
airmax Wireless Broadband CPE Datasheet Models: AG-HP-2G16, AG-HP-2G20, AG-HP-5G23, AG-HP-5G27 High Performance, Long Range Integrated InnerFeed CPE
airmax Wireless Broadband CPE Models: AG-HP-2G16, AG-HP-2G20, AG-HP-5G23, AG-HP-5G27 High Performance, Long Range Integrated InnerFeed CPE Easy Assembly and Installation Utilizing InnerFeed technology,
Displayport Extender via 2 multimode fibers LC Duplex Connector Extends Displayport Link up to 200 meters
Description Displayport combines the audio and video through an interface. It supports high resolution displays and multiple displays with a single cable, and increases the efficiency and bandwidth of
SPECIAL SPECIFICATION 6819 Wireless Ethernet Microwave Radio
2004 Specifications CSJ 2266-02-127 SPECIAL SPECIFICATION 6819 Wireless Ethernet Microwave Radio 1. Description. Furnish and install Wireless Ethernet Microwave Radio (WEMR) as shown on the plans, as detailed
AP60. 9 Wireless. Wireless-b/g/n Long Range PoE Access Point. Wireless-b/g/n Long Range Radio. Passive PoE and 4-LAN Ports. IP Finder Management 4 LAN
-b/g/n Long Range PoE Access Point E ver since AirLive introduced the world s first multi-function in 2002, the AirLive access points have been renowned for their reliability, performance, and rich features.
Antenna Trainer EAN. www.edibon.com. Technical Teaching Equipment INTRODUCTION
Antenna Trainer EAN Technical Teaching Equipment Products Products range Units 3.-Communications INTRODUCTION Antennas are the main element of aerial communications. They are the transition between a transmission
Loop-V4300 MINI DACS E1/ T1 CONVERTER
MINI DACS Loop-V4300 MINI DACS / CONVERTER Description Loop-V4300 Mini DACS / converter provides both DS0 and n x 64 Kbps cross-connect between any and ports and to format conversion functions. to conversion
Smart Wireless Devices. LAN-WMBUS-G Wireless MBUS, high performance Temperature, Humidity and Pulse counting device.
Smart Wireless Devices LAN-WMBUS-G Wireless MBUS, high performance Temperature, Humidity and Pulse counting device. The LAN-WMBUS-G-T(E)/(H)-(P) is a temperature/humidity sensor and pulse counter. It is
MLC 9000+ TM Maximum Productivity and Versatility for Control without Compromise!
Data Sheet Maximum Productivity and Versatility for Control without Compromise! Basic Bus Communication Module DESCRIPTION The Basic Bus Communication Module (BCM) is part of the MLC 9000+ DIN rail mount
LT-82 Stationary IR Transmitter
LT-82 Stationary IR Transmitter Configuration LT-82-0 (North America) LT-82-02 (Asia, UK) LT-82-03 (Euro) The Listen LT-82 is the heart of a stationary IR listening system. It takes the desired audio signal
Stand Alone POTS Fiber Optic System. P31372 Station (Subscriber) Unit P31379 Remote (Exchanger) Unit. Description & Installation
Stand Alone POTS Fiber Optic System P31372 Station (Subscriber) Unit P31379 Remote (Exchanger) Unit Description & Installation Printed in USA 09/11 TO466 Rev. A Table of Contents Page 1.0 SCOPE 2 2.0 PRODUCT
HDO700 P FIBRE OPTIC TRANSMITTER
Timo Rantanen 18.1.2011 1(5) HDO700 P FIBRE OPTIC TRANSMITTER HDO700 P is a high performance, extremely linear externally modulated 1550 nm transmitter for HDO fibre optic CATV link. This transmitter type
