1 DREXELBROOK A Leader In Level Measurement Solutions USonic-R Series Ultrasonic Level Measurement System User Friendly Set the measurement range directly in inches, feet, millimeters, centimeters, or meters via the display with environmentally sealed keypad. The display is menu driven and can easily be configured without detailed procedures: no cryptic codes, no problems. 2-Channel USonic-R can be used in a variety of Level and Open Channel Flow applications. Level Distance Open Channel Flow rate Totalization Pump Alternation - up to 6 pumps Differential Level (Bar Screen) Submerged Flow 4-20mA Signal Outputs w/ Modbus RTU 6 SPDT relays for control or alarm Programmable Batch Sampler Activation Data Logger - 1 to 24 Month Easy Set-Up Via Menu driven configuration via local display with environmentally sealed keypad The USonic-R Continuous Ultrasonic Level Series is a versatile package available with analog outputs, and 6 SPDT relays. This multifunctional system can be used in a wide variety of applications ranging from simple indication of level as well as open channel flow rate and totalization to more demanding two channel inputs such as differential level and submerged flow. When relay outputs are required, (6) SPDT relays rated at 250VAC allows additional features such as alarm or control functions plus Batch Sample Activation and Pump Alternation of up to 6 pumps. The USonic-R continuous ultrasonic level system features a full, 7-digit, Back-Lit, LCD, display. The large display can be viewed easily from a distance or when process lighting conditions are dim. The USonic-R is preprogrammed with common tank shapes and Open Channel Flume and Weir characterizations. The menu driven software additionally offers a 21-point strapping table for non-linear inputs in level, volume or open channel flumes and weirs.
2 SmartGain Eliminates interfering signal reflections from agitators and other internal vessel obstructions without the need to empty the vessel and without operator intervention. Easily ignores pipes and similar obstructions that may be within the sonic beam path. Automatically ignores difficult internal obstructions No user adjustments required Full Tank Measurement Transducer can be recessed in a 2-inch or larger ID nozzle to allow level measurements to the very top of the vessel. Bench Configuration Eliminates the need to move process material levels for configuration 2-Inch Nozzle Mounting Compact transducer design allows mounting in any 2-inch nozzle. It also allows for a recessed nozzle mounting enabling level to be read to the very top of the vessel. Ideal for Hazardous Area Installations Units designed for installations in Class 1 Div. 2, Zone 2 environments with sensors designed for Class I Div. 1, Zone 0, Zone 1. Easy View Display 1 x 4 Backlit LCD display, wall mount. 2-line display, top line - 10 characters 9.8 mm tall, second line - 7 characters 15.5 mm tall Software Options Level, distance in: %, inches, feet, mm, cm, m Flow rate in: GPM, M3/Hr., L/S, L/M (2) Totalizers, (1) resettable, and (1) nonresettable. Differential level Traveling Bar Screen, Submerged flow. Pump Alternation up to 6 pumps. Batch Sample Activation based on totalized flow with dry relay contact closure with adjustable pulse durations. Characterizations of common flumes and weirs plus customer configuration of nonstandard flumes and weirs via a 21-point strapping table. Supported Flume & Weir Characterizations: Parshall Rectangular (With & Without end contractions), Trapezoidal (Cippoletti) Weir Trapezoidal Flume V-Notch Weir Leopold-Lagco Palmer-Bowlus Compound Weir H Flume.
3 Ignore difficult internal obstructions with patented SmartGain SmartGain is a standard feature with every system and prevents unwanted reflections from internal obstructions and agitator blades. SmartGain automatically controls the transmitter gain (sensitivity to returned echoes). Without user intervention, the USonic-R ignores obstructions that are mounted within the sonic beam path. SmartGain also provides measurement advantages in horizontal cylinders and spheres by reducing the effects of multiple reflection signal paths. 2" dia. nozzle Ignore a 2-Inch (50 mm) Pipe The edge of a 2-inch (50 mm) pipe can be as close as ½ inch (12 mm) from the centerline of the transducer, and ignored. Pipe Obstruction in Beam Path Ignore a 1-Inch (25 mm) Pipe The edge of a 1-inch (25 mm) pipe can be 1-inch (25 mm) from the centerline of the transducer, and ignored. 10 Quick Start-Up: 1. Choose Level or Flow as an input type. 2. Choose Configuration Units (Feet, Inches, Meters, Centimeters, Millimeters). 3. Enter Tank Height. 4. Enter LRV (4 ma point) and URV (20 ma point). That s all that is needed to start measuring Level! Easy user-defined configuration as simple or complex as needed. In addition to a quick and easy start-up, in-depth configuration allows the conversion of Level to Volume through internal strapping tables or open channel flow tables and totalizer settings. The USonic-R has (2) 7-digit totalizers per channel for use in flow measurement inputs; one totalizer per channel is resettable. Systems settings allow user-defined system gain, repetition rates, time delay, error signals, display options, diagnostics and more.
4 Specifications Input Power 120 VAC & 24 VDC 240 VAC & 24 VDC Output signal options (2) Active 4-20mA with Modbus RTU Maximum Loop Resistance 1000 ohms Output Mode Level, Distance, Flow, Volume Display Indications Level, Distance, Flow Rate, Volume, Totalization, Temperature, Signal Strength, Milliamp. User selectable, multiple selections can be scrolled automatically. Range 1 to 30 ft. (0.3 to 9.1m). Near Zone 12 inches (305 mm). Minimum span 3 inches (76 mm). Maximum Span 30 ft. (9.1 m). Display 2-line, backlit LCD, UV protected. Top line, 10 characters 9.8 mm tall. Second line, 7 characters 15.5 mm tall. Accuracy +/- 0.15% or 0.2 inch (5 mm) of sensor range, which ever is greater. Repeatability < 0.12 inch (3 mm) Resolution < 0.12 inch (3 mm) Response Time Less than 1 second Ambient Temperature Limits -40 F to 158 (-40 C to 70 C). Data Logger - 1 to 24 Month Maximum time period dependant on sample rate Optional RS232 to DB9 cable (# ) is required to download Datalogger to PC. 16 ft. (5 m) Temperature Compensation Built-in, Automatic and readable from display. Fail-Safe 3.7 and 22 ma error signals user selectable for Lost Echo and Near Zone violations. Configuration Local Display with Keypad, password protected Signal Damping User programmable from 0 99 seconds. Relays: (6) 5A 250VAC with 10 user defined trip points. SmartGain Standard feature on every system Sensor 6 CPVC, rated -40 F to +158 F at 50 psig. (-40 C to +70 C at 3.4 bar) Remote Sensor Cable Length Max. cable length to 1200 ft. (365 m) Max. cable length factory supplied, 300 ft. (91 m) Sensing element connection 2-inch & ¾ NPT/BSP fitting, CPVC Flange mounting (via threaded flanges) Frequency 50KHz Beam Angle Conical, 3db down Enclosures Electronics: Fiberglass reinforced Polyester (FRP) to NEMA 4X (IP-66) Sensor: CPVC rated NEMA 6 (IP-68) Approvals Electronics: Class I, Div. 2, Zone 2 hazardous locations. Sensors: FM / FMc - Class I, Div. 1 * Specifications subject to change without notice
5 Model Numbering USonic-R Technology USonic-R Continuous Line-Powered Ultrasonic Level Measurement System Power VAC, 24 VDC VAC, 24 VDC Output 1 Analog 4-20 ma outputs with Modbus Approvals 1 FM / FMc - Class 1, Div. 2 Sensors 0 Without 1 One Sensor 3/4" / 2" NPT (FM / FMc - Class I, Div. 1) 2 Two Sensors 3/4" / 2" NPT (FM / FMc - Class I, Div. 1) 3 One Sensor 3/4" / 2" BSP (G) (FM / FMc - Class I, Div. 1) 4 Two Sensors 3/4" / 2" BSP (G) (FM / FMc - Class I, Div. 1) 5 One Sensor 3/4" / 2" NPT 6 Two Sensors 3/4" / 2" NPT 7 One Sensor 3/4" / 2" BSP 8 Two Sensors 3/4" / 2" BSP Sensor #1 Cable length 0000 Without Ft. Continuous Run Ft. Continuous Run Ft. Continuous Run Ft. Continuous Run Ft. Continuous Run Sensor #2 Cable length 0000 Without Ft. Continuous Run Ft. Continuous Run Ft. Continuous Run Ft. Continuous Run Ft. Continuous Run USR Additional or Replacement USonic-R Remote Sensor Technology USS Additional or Replacement USonic-R Remote Sensor Accessories: Enclosure Optional RS232 to DB9 cable 16 ft. (5 m) and P.C. Software is required to download Datalogger to 1 PC. CPVC (Part # ) Mounting 1 3/4" / 2" NPT - FM / FMc Approved Class I, Div 1 2 3/4" / 2" BSP (G) - FM / FMc Approved Class I, Div 1 3 2" NPT with 1/2 NPT Electrical Connections - Approvals: ATEX / CE (Pending) 4 2" BSP with M20 Electrical Connections - Approvals: ATEX / CE (Pending) Interconnecting cable xxxx Up to 300 ft. continuous run in 50 ft. increments * Model Number subject to change without notice
6 USR Sensor #2 Cable length 0000 Without Ft. Continuous Run Ft. Continuous Run Ft. Continuous Run Ft. Continuous Run Ft. Continuous Run USonic-R Level Measurement System Model Numbering Additional or Replacement USonic-R Remote Sensor Technology USS Additional or Replacement USonic-R Remote Sensor Enclosure 1 CPVC Mounting 1 3/4" / 2" NPT - FM / FMc Approved Class I, Div 1 2 3/4" / 2" BSP (G) - FM / FMc Approved Class I, Div 1 3 2" NPT with 1/2 NPT Electrical Connections - Approvals: ATEX / CE (Pending) 4 2" BSP with M20 Electrical Connections - Approvals: ATEX / CE (Pending) Interconnecting cable xxxx Up to 300 ft. continuous run in 50 ft. increments USS 1 DREXELBROOK 205 Keith Valley Road, Horsham, PA U.S.A. Tel: Fax: [email protected] Web: AMETEK, Inc. All rights reserved. Printed in the U.S.A. USR-XX-A EDO# Issue# 8
713 Open Channel Flowmeter and Transmitter. All-in-one package for open channel flow measurement.
and Transmitter All-in-one package for open channel flow measurement. 3.1 NEW Class 1, Division 1 Approved Sensor As our products are continuously improved, we reserve the right to make any change in the
O C M III. Open Channel Flow Monitor
O C M III Open Channel Flow Monitor Part 1. General 1.1 Scope A. This section describes the requirements for an ultrasonic flow transmitter with sensor and temperature compensation probe. B. Under this
Regards from the Team at Rheology Solutions.
Rheology Solutions is the sole Australian distributor of this product range and we welcome the opportunity of discussing your application requirements. We hope the information you are seeking is contained
Mobrey open channel flow measurement systems
Technical specification sheet IP2039 October 2008 Level Mobrey open channel flow measurement systems Comprising: MCU Flow log datalogging control unit MSP900** Ultrasonic level transmitter Mobrey MCU/MSP
MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter
Thermal Mass meter and Temperature Transmitter Description The MTI10 insertion thermal mass flowmeter and the MTL10 in-line thermal mass flowmeter provide accurate mass flow measurement of clean, dry gases
FLOW HUNTER II & XDS 03
FLOW HUNTER II & XDS 03 Open Channel Flow Meter Instruction Manual November 2012 Edition ECHO Process Instrumentation, Inc. PO Box 800, Shalimar, FL 32579 USA Phone: 850-609-1300, Fax: 850-651-4777 Email:
FLOW SYSTEM flow measurement system in open channels and non-pressurized pipes
FLOW SYSTEM flow measurement system in open channels and non-pressurized pipes The flow measurement in open channels is based on the measurement of the increase in height due to the insertion of a suitable
RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits
RHE12 Hazardous Area Coriolis Mass Flow Transmitter Features Field mounting Compact, pressure safe housing ATEX and CSA approvals for installation in hazardous areas 24 VDC power supply Configurable analog
Series DFMT Digital Paddlewheel Flowmeter
Series DFMT Digital Paddlewheel Flowmeter Bulletin F-DFMT Specifications - Installation Operating Instructions -/8 [00] -/ [8] -/8 [00] A The Series DFMT Digital Paddlewheel Flow Transmitter provides instantaneous
Easy drop down menu allows quick set up, the clear large display offers a choice of menus and the interface echo can be constantly seen if needed.
Sludge Finder 2 Sludge Finder 2 Is a proven effective sludge blanket interface monitor in both waste water and industrial applications. Sludge Finder 2 provides a continuous level indication and 4 20 ma
Thermatel Model TA1 Mass Flow Transmitter
Thermatel Model TA1 Mass Flow Transmitter D E S C R I P T I O N Thermatel Thermal Mass Flow Transmitter, Model TA1, provides a high level of performance in mass flow measurement of air and gases. Powerful
Mobrey open channel flow measurement systems
Specification sheet IP2039 Sept 2005 Level Mobrey open channel flow measurement systems Comprising : MCU Flow log datalogging control unit MSP900** Ultrasonic level transmitter Mobrey Measurement MCU/MSP
Chapter2. Installation
Chapter2. Installation Power Supply Requirements The ULM-1000C operates from a DC supply of 20 30V and will typically draw less than 0.08A. All electronic products are susceptible to electrostatic shock,
Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43
Data Sheet Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43 2-Wire Operation Significantly reduces installation costs when compared to a traditional 4-wire magmeter. ±0.5% of rate system accuracy. Patented
SELECT MOUNT MONITOR
WIRELESS ULTRASONIC LEVEL MONITORING SYSTEM FLO-CORP s AccuTank Wireless Ultrasonic Level Monitoring System monitors process conditions through cellular networks and satellites allowing the user to access
PIEZOMETER AIRFLOW MEASURING RING
PIEZOMETER AIRFLOW MEASURING RING M.K. Plastics is pleased to introduce The Piezometer Airflow Measuring Ring, now available as an accessory for our steel Axijet fans. The system consists of a Piezometer
3DLevelScanner II TECHNICAL DATA SHEET
TECHNICAL DATA SHEET Changing the market from level to volume APM`s 3DLevelScanner incorporates advanced technology for accurately measuring bulk solids and powder stored in silos and open bins of all
key- precision Tecum cuil Ludere ipsae. Possem Precision level detection When space and price matter Pointek CLS 100
Pointek CLS 100 Compact design and short insertion length. Ideal for constricted spaces and for small vessels or pipes up to 100 mm (4 ). Tecum cuil Ludere ipsae. Possem Precision level detection When
Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Measurement & Control Solutions. Benefits.
GE Measurement & Control Solutions Sentinel LCT Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement Benefits Extremely reliable and highly accurate flowmeter, designed specifically
AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products
Data sheet DS/AT500-EN Rev. M AT500 Magnetostrictive Level Transmitter Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products Features Mounts from Top of Tank High Resolution
www.kem-kueppers.com [email protected] Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter
www.kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter Description The KVO Vortex flow meters utilize two primary sensing elements a vortex shedding
ISO-9001:2000 certified. EE300 Series Electromechanical Inventory Level Measuring System. Aplus Finetek Sensor, Inc.
ISO-9001:2000 certified EE300 Series Electromechanical Inventory Level Measuring System Aplus Finetek Sensor, Inc. PRODUCT INTRODUCTION OPERATING PRINCIPLE The EE300 series level measuring system is a
Easily installed and simple to set up, Flow Pulse uses an acoustic technique never before seen in flow measurement to deliver reliable results across
Flow Pulse Unique, non-invasive clamp-on flow monitor Easily installed and simple to set up, Flow Pulse uses an acoustic technique never before seen in flow measurement to deliver reliable results across
Unidirectional Transmitter/ Receiver Units Introduction
Unidirectional Transmitter/ Receiver Units Introduction Wireless Input/Output (I/O) connects directly to analog, discrete and pulse transducer signals. The signals are transmitted by radio and either re-created
FLARE MONITORS FLARE MONITOR (FM) PILOT MONITOR (PM) FLAME INTENSITY (FI)
FLARE MONITORS Infrared Sensors for Monitoring Smokeless Flares, Pilots, and Flame Intensity FMDS2014 FLARE MONITOR (FM) Monitor smokeless flare combustion efficiency to maximize destruction of hazardous
Electronic Flow Switches
Industries Electronic Flow Switches Petrochemical Refining Oil Production Water Treatment Pharmaceutical Food and Beverage Pulp and Paper Power Production Gas Processing Mining Biotechnology Semiconductor
Thermal Mass Flow Meter (Series MST)
Overview MaxiFlo TM MST series Thermal Mass Flow Meter is the instrument of choice for reliable and accurate measurement of mass flows for various gases. It measures the mass flow of gas based on constant
COMBIMASS. Technical Data COMBIMASS eco-bio +
COMBIMASS Technical Data THE SYSTEM COMBIMASS The field transmitters of the COMBIMASS eco series are suitable for gas flow measurement and cover a wide range of different applications. The instruments
Mobrey Ultrasonic. MSP900SH Level and MSP900FH Flow Transmitters. Product Data Sheet February 2015 IP2032, Rev BA
Mobrey Ultrasonic MSP900SH Level and MSP900FH Flow Transmitters Product Data Sheet February 2015 IP2032, Rev BA Non-contacting measurement with no moving parts Fast and simple to install and configure
IFC 070 Technical Datasheet
IFC 070 Technical Datasheet Electromagnetic signal converter Battery driven with low energy consumption Quick and easy to install and operate External data logger and GSM module for remote data transfer
Technical Information RIA14
TI00143R/09/EN/04.14 71256618 Products Solutions Services Technical Information RIA14 Loop powered field indicator With explosion proof enclosure (according to Ex d) Application Oil & gas Petrochemical
Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION
Modular, Customizable Wire Replacement 128 / 256 Bit AES Encryption Software Selectable RF Transmit Power Software Selectable Over-the-air Data Rate Modbus ASCII /RTU Compatible Wide Operating Temperature
Sanitary Type Electronic Flow Switches
Industries Pharmaceutical Sanitary Type Electronic Flow Switches Food and Beverage Biotechnology Semiconductor Water Treatment S Series Ameritrol, Inc. Instruments and Controls Features No Moving Parts
Technical Data Sheet. 3DLevelScanner
Changing the market from level to volume Technical Data Sheet APM`s 3DLevelScanner incorporates advanced technology for accurately measuring bulk solids and powder stored in silos and open bins of all
INTREPID Perimeter Intrusion Detection System
TM INTREPID Perimeter Intrusion Detection System Next Generation Perimeter Protection icropoint Cable combines patented Southwest Microwave technology with microprocessor power and laptop computer convenience.
Perimeter Security System
TM Perimeter Security System The Next Generation Perimeter Security System ICRONET combines patented Southwest Microwave technology with microprocessor power and laptop computer convenience. It is a sophisticated
Configuring the HydroRanger 200 to measure open channel flow. Specific parameter setting to configure the following primary measurement devices:
Flow Application Configuration AG040308 Configuring the HydroRanger 200 to measure open channel flow Objective: Specific parameter setting to configure the following primary measurement devices: exponential
How To Use A Ds340 (Dsp)
Ideal for monitoring dust levels in the exhaust gas of industrial combustion or air filtration processes. Innovative Dynamic Detection Principle (DDP) measurement technique Immune to gradual reductions
Interface Level And Point Level Analyzers & Sensors
Interface Level And Point Level Analyzers & Sensors Model 2511 Analyzer Model 2505 System Model 2120 System Royce now offers a complete line of Interface Level and Point Level Analyzers that make it possible
For Multi-Parameter Meters see mvx
BULLETIN BULLETIN EM20607 VORTEX IN-LINE FLOW METERS Design Features For Multi-Parameter Meters see m Principles of Operation n No moving parts to wear or fail. n Electronics can be remotely mounted up
Preliminary. Dual-line FLOW rate/totalizers. Pr ovu Model PD6200 Analog Input. Pr ovu Model PD6300 Pulse Input. Analog Inputs.
Dual-line FLOW rate/totalizers Pr ovu PD6200 Analog Input ProVu Se r i e s Pr ovu PD6300 Pulse Input Analog Inputs 0-20 ma, 4-20 ma, 0-5 V, 1-5 V, and ±10 V Inputs Isolated 24 VDC @ 200 ma Transmitter
Typical Aluminum GFM Mass Flow Meter
MASS FLOW METERS Design Features n Rigid metallic construction. n Maximum pressure of 1000 psig (70 bars). n Leak integrity 1 x 10-9 of helium. n NIST traceable certification. n Built-in tiltable LCD readout.
BM SERIES WAVE COMPACT 6.3 GHZ CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz)
CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz) DESCRIPTION The Radar Level Meters of BM COMPACT WAVE 6.3 GHz series are excellent devices for no contact level measurement. The microwave impulses, emitted
Thermatel Enhanced Model TA2 Thermal Mass Flow Meter
Thermatel Enhanced Model TA2 Thermal Mass Flow Meter D E S C R I P T I O N The Thermatel Enhanced Model TA2 Thermal Mass Flow Meter provides reliable mass measurement for air and gas flow applications.
Centro-Matic Automatic Lubrication Systems System Controls
Selecting the right controls for your automated lubrication system is one of the last steps in the design process. Several different models may be chosen to control power-operated pumps, depending on the
API Marine. BMS Presentation. Ballast Measurement Systems
API Marine BMS Presentation Ballast Measurement Systems BMS4 Typical Configuration BMS4 Typical Configuration BMS4 Extended Configuration BMS4 System (24 tanks) Air regulator Terminal block Drain/Air Filter
SHARKY 775 COMPACT ENERGY METER ULTRASONIC
APPLICATION The ultrasonic compact energy meter can be used for measuring the energy consumption in heating / cooling application for billing purposes. FEATURES 4 Approval for ultrasonic meter with dynamic
FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX 759 26-06-2007 759 M1 02 E MES FLOW CALCULATOR 759-02/1
BAMOPHOX 759 E - M FLOW CALCULATOR INSTRUCTION MANUAL MESURES 22, Rue de la Voie des Bans - Z.I. de la Gare - 95100 ARGENTEUIL Tél : (33) 01 30 25 83 20 - Web : www.bamo.fr Fax : (33) 01 34 10 16 05 -
PolyGard Carbon Monoxide CO Transmitter ADTX3 1110
PolyGard Carbon Monoxide CO Transmitter ADTX3 1110 DESCRIPTION CO transmitter including digital measurement value processing and temperature compensation for the continuous monitoring of the ambient air
920 Series. Dual-point heat-tracing control system. Product overview. 920*E4FWL*SIS302*SS3102 shown
Self-Regulating 920 Series Dual-point heat-tracing control system Power-Limiting Mineral Insulated 920*E4FWL*SIS302*SS3102 shown Product overview The DigiTrace 920 is a compact, full-featured, microprocessor-based,
SHARKY 775 COMPACT ENERGY METER ULTRASONIC
APPLICATION The ultrasonic compact energy meter can be used for measuring the energy consumption in heating / cooling application for billing purposes. FEATURES 4 Approval for ultrasonic meter with dynamic
INTRODUCTION / TABLE OF CONTENTS
1 2 INTRODUCTION / TABLE OF CONTENTS Step One The small tank sensor is an innovative level sensor family that replaces float, conductance and pressure sensors that fail due to contact with dirty, sticking
DigitalFlow GF868. Panametrics Flare Gas Mass Ultrasonic Flowmeter with Extended Performance Range. GE Sensing & Inspection Technologies.
GE Sensing & Inspection Technologies DigitalFlow GF868 Panametrics Flare Gas Mass Ultrasonic Flowmeter with Extended Performance Range Applications The DigitalFlow GF868 flowmeter is a complete ultrasonic
TC 1818a. Operating Guide. Control Module SWM-015.5
TC 1818a Control Module Operating Guide SWM-015.5 This guide is intended solely for use by owners of Thermon HeatChek TM heat tracing control and monitoring units. This manual describes operation for TC
Measurement. SITRANS F US Inline. Transmitter FUS080/FUE080 4/219
Siemens AG 2010 Flow Measurement Overview The transmitter is available in an IP67/NEMA X/6 enclosure and is designed for use in the flowmeters series: SONOKIT (1- or 2-track) FUS380 (2-track) FUE380 (2-track)
How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)
transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control
Ultrasonic level. Solutions for a world of applications. Process Instrumentation. siemens.com/ultrasonic
Ultrasonic level Solutions for a world of applications Process Instrumentation siemens.com/ultrasonic 2 2 Since the early 1970s... Siemens has been your partner in ultrasonic level measurement. This experience
PRODUCT PROFILE FEATURES
PRODUCT PROFILE Pressure Transmitters & Pneumatic Transducer Airflow Transmitter, Differential Air Pressure Transmitter and Differential & Gauge Liquid/Gas Pressure Transmitter FEATURES AIRFLOW TRANSMITTER
Steven R. McManus Environmental Product Support Teledyne Isco
Steven R. McManus Environmental Product Support Teledyne Isco Flow Measurement Applications and Technologies. Methods of flow measurement Technologies of flow measurement Flow Rate Applications Channel
Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000
Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000 Description Firetrol FTA1000 Full Voltage Fire Pump Controllers are intended for use with electric motor driven fi re pumps
In-Line Electronic Flow Switches
In-Line Electronic Flow Switches Industries Petrochemical Refining Oil Production Water Treatment Pharmaceutical Food and Beverage Pulp and Paper Power Production Gas Processing Mining Biotechnology Semiconductor
Wireless Data Logger Monitoring Systems
Wireless Data Logger Monitoring Systems Table of Contents About MadgeTech, Inc. Wireless Systems & Components Wireless Data Loggers 2000A Wireless Data Logger Models MadgeTech Cloud Services MadgeTech
UTM10 Series Ultrasonic Transit-time Flowmeters
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
Galvanic Parts Per Million Dissolved Oxygen Systems
Galvanic Parts Per Million Dissolved Oxygen Systems Model 900 Portable s Model 9100 Model 9200 Model 9300 The Royce line of PPM level dissolved oxygen (DO) analyzers is the largest, most varied line in
Level Plus. Magnetostrictive Liquid-Level Sensors with Temposonics Technology. M-Series Model MR Transmitter with Analog Output.
Level Plus Magnetostrictive Liquid-Level Sensors with Temposonics Technology M-Series Model MR Transmitter with Analog Output Data Sheet SENSORS Document Part Number 550677 Revision J Features 4 to 20
Open Channel & Partially Filled Pipe Ultrasonic Flow Meters
Open Channel & Partially Filled Pipe Ultrasonic Flow Meters DYNAMETERS series DMDF-OP has three types as below: DMDF-OP-A for partially filled pipe application; DMDF-OP-B for partially filled pipe, channel
Pump_PT580. Optional. Optional. Modbus. Remote Reset Local Display PLC/DCS PT580-CFG PCM370 DTM96. Buffered Output. Dual Relay Output.
Pump_PT580 Optional PT580-CFG PCM370 Optional DTM96 Buffered Dual Relay Remote Reset Local Display Condition Monitoring System PLC/DCS PT580 Digital Vibration Switch Introduction The PT580 Digital Vibration
Product Data. Model 575 Series Submersible Level Transmitters ELECTRONIC PRESSURE MEASUREMENT PRODUCTS DESCRIPTION FEATURES APPLICATIONS
EPP - 1 DECRIPTION The odel 575 is used in general water/wastewater applications. The transmitter is offered in a standard non-clogging snub nose end, flush diaphragm or protected flush diaphragm with
Automatic Transfer Switch Controller
Automatic Transfer Switch Controller Decision-Makerr MPAC 1500 Model KBS with Decision-Makerr MPAC 1500 Controller Applicable Models Model Description KCS Standard-Transition Any Breaker ATS ] KCP Programmed-Transition
Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5
Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service program ULTRA 000 programmable switch outputs Hysteresis
The Unique Accelabar Flow Meter
The Unique Accelabar Flow Meter The Accelabar is a new and unique flow meter that combines two differential pressure technologies to produce operating ranges never before attainable in a single flow meter.
Short Form Catalogue. Alarm Systems. Reliable Supervision and Control
Short Form Catalogue Alarm Systems Reliable Supervision and Control Alarm Monitors and Indicators The SELCO product range includes a number of alarm monitors and indicator panels for use in numerous applications.
Digital inductive conductivity transmitter
Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections
THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES
TSI and TSI logo are registered trademarks of TSI Incorporated. SmartTune is a trademark of TSI Incorporated. THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES IFA 300 Constant Temperature Anemometry
Rosemount 333 HART Tri-Loop
Product Data Sheet Rosemount 333 Rosemount 333 HART Tri-Loop HART-TO-ANALOG SIGNAL CONVERTER Convert a digital HART signal into three additional analog signals Easy to configure and install Accessory product
Heating, air-conditioning, cooling
Series description Design High efficiency, single stage, low pressure, inline centrifugal pump Supplied with EC motor and electronic duty adaptation Available in glanded construction, mechanical shaft
MJK 713 Open Channel Flowmeter
MJK 713 Open Channel Flowmeter As our products are developed continuously we reserve the right to make any change in the dimensions and the specifications. 1 UL Approvals UL-CUL listed, File # E 194021
www.kem-kueppers.com [email protected] Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters
www.kem-kueppers.com [email protected] Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters Description The Tricor Mass Flow Meters measure simultaneously mass
Flow Monitoring System
FMS-3 Product Data Sheet PS-00028 April 1997 Flow Monitoring System FMS-3 Flow Monitoring System The Micro Motion FMS-3 Flow Monitoring System is a microprocessor-based batch controller with rate, total,
Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface
Release date: 06-0- 09: Date of issue: 06-0- 009_eng.xml Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service
2.24. Pump Controller 704. Data Sheet
Pump Controller 704 2.24 There are several reasons to choose an MJK pump controller. Pump controller 704, as described in this data sheet, was introduced in 1989. It has been updated several times with
Non-invasive CLAMP-ON ultrasonic flowmeter for liquids
Non-invasive CLAMP-ON ultrasonic flowmeter for liquids Model CU100: non-invasive installation flowmeter, with transducers installed outside the pipe Installation in horizontal or vertical pipe Easy and
Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc
Ultrasonic sensors for high precision detection of clear and transparent objects Clear object detection, inspection on transparent or highly reflective film and liquid level measurement Standard M18 tubular
Process Alarm Solutions
Process Alarm Solutions Reliable Supervision and Control www.selco.com SELCO flexible alarm panels for supervision and control SELCO provides efficient and reliable solutions for alarm monitoring of electrical
Multifunction devices
devices devices devices, electronic Type Page LED multifunction displays pulse, frequency, time (DC) Codix 524 240 pulse, frequency, time (AC+DC) Codix 544 243 LCD multifunction preset counters 1 or 2
Flow. Hach Sigma 950 Series Permanent/Portable. Open Channel Flow Meters. Features and Benefits DATA SHEET. Versatility and Customization
DATA SHEET Hach Sigma 950 Series Permanent/Portable Open Channel Flow Meters Flow Hach Sigma 950 Series Permanent/Portable Open Channel Flow Meters provide portable and/or permanent single-channel monitoring
Features Direct mass flow monitoring eliminates need for separate temperature and pressure inputs. Accuracy +/- 1% of reading plus 0.
Immersible Thermal Gas Mass Flow Meter Features Direct mass flow monitoring eliminates need for separate temperature and pressure inputs Accuracy +/- 1% of reading plus 0.5% of full scale Patented Dry-Sense
Environmental Equipment, Inc. IMR 5000 Continuous Flue Gas Monitoring System IMR 5000
IMR 5000 Continuous Flue Gas Monitoring System The IMR 5000 is state-of-the-art continuous flue-gas monitoring system, and is designed for a wide variety of flue-gas monitoring applications. The IMR 5000
SECTION 23 90 13 NOx, CO AND NATURAL GAS DETECTION, MONITORING AND ALARM CONTROL SYSTEMS
SECTION 23 90 13 NOx, CO AND NATURAL GAS DETECTION, MONITORING AND ALARM CONTROL SYSTEMS PART 1 - GENERAL 1.01 Section Includes A. Requirements for provision of the Natural Gas (CH4), Carbon Monoxide (CO)
Microcor Wireless Transmitter (MWT)
Rohrback Cosasco Systems, Inc. Microcor Wireless Transmitter (MWT) Features: Highly Secure and Reliable Self Organizing Wireless Mesh Network High Resolution Metal Loss Measurement for all process environments
Electronic Pressure Switch EDS 300
Electronic Pressure Switch EDS 300 User manual Page 2 of 16 Content 1. Functions of the EDS 300...3 2. Mounting...3 3. Operating keys on the membrane keypad...4 4. Digital display...4 5. Output function...5
red-y smart series product information Thermal Mass Flow Meters and Controllers for Gases
red-y smart series product information Thermal Mass Flow Meters and Controllers for Gases Reliable and accurate: Thermal Mass Flow Meters and Controllers Reliable technology and industry standard interfaces
Replacing Displacers with Guided Wave Radar
ROSEMOUNT GUIDED WAVE RADAR Replacing Displacers with Guided Wave Radar KEY POINTS Mounting flanges vary by displacer supplier Probe must extend the of the displacer chamber Single rigid probes are the
330505 Low Frequency Velocity Sensor
330505 Low Frequency Velocity Sensor Bently Nevada* Asset Condition Monitoring Description The Bently Nevada Low Frequency Velocity Sensor is designed to measure absolute (relative to free space) bearing
CruzPro VAF110. AC Volts, Amps, Frequency, kw Monitor
CruzPro VAF110 AC Volts, Amps, Frequency, kw Monitor Table of Contents Introduction............................ 3 Specifications........................... 4 Installation..............................5
Help. Help Software Tutorial. Building a load sizing project with an ME Series Humidifier
Help Help Software Tutorial Building a load sizing project with an ME Series Humidifier 502-B 18 Aug 2015 Help Tutorials provide step-by-step examples of complete load sizing projects and browser projects
Liquid Level Limit Switch liquiphant T FTL 20
Technical Information TI 64F/4/ae Liquid Level Limit Switch liquiphant T FTL 0 Level limit switch for liquids Applications The Liquiphant T FTL 0 is a level limit switch for virtually any kind of fluid
EQUIPMENT SPECIFICATIONS
EQUIPMENT SPECIFICATIONS IC-1600 Intelligent Controller The IC-1600 Intelligent Controller is a fully intelligent panel that has a complete database on board. It operates in conjunction with the Access
330450 High Temperature Acceleration System Bently Nevada* Asset Condition Monitoring
330450 High Temperature Acceleration System Bently Nevada* Asset Condition Monitoring Description The standard 330400 Accelerometer has a limited temperature range it can be exposed to, due to its signal