Honeywell Analytics Lines of Business
|
|
|
- Malcolm Owen
- 10 years ago
- Views:
Transcription
1 Honeywell Analytics Lines of Business Commercial Vulcain-brand gas detection from standalone units to fully engineered, multipoint systems, all offering cost-effective regulatory compliance» Applications: parking structures, chillers, mechanical rooms, office towers, commercial buildings, shopping centers, swimming pools, golf courses, schools and universities, laboratories Industrial Renowned Sieger and Manning gas detection systems with advanced electrochemical, infrared and open path sensing technologies» Applications: oil and gas, cold storage, water/wastewater treatment, chemicals, engine rooms, plastics and fibers, agriculture, printing and light industrial Portables Single or multi-gas Lumidor and other premium detectors with compact, lightweight designs ranging from simple alarm only units to advanced, fully configurable and serviceable instruments» Applications: underground utility and electricity ducts, boiler rooms, post-fire sites, sewers, industrial plants, industrial hygiene, first responder teams, remote fleets Find out more Contact Honeywell Analytics: Americas Honeywell Analytics Inc. 405 Barclay Blvd. Lincolnshire, IL USA Tel: Toll free: Fax: Technical Services High Tech/Government A complete portfolio of gas and chemical detection instrumentation including infrared spectroscopy (MST) with no cross interference, to Chemcassette paperbased solutions (MDA Scientific) offering detection down to parts per billion» Applications: semiconductor manufacturing and nanotechnology, aerospace propulsion and safety, specialty chemicals industry, research laboratories, emergency response Europe, Middle East, Africa Life Safety Distribution AG Wilstrasse 11-U31 CH-8610 Uster Switzerland Tel: +41 (0) Fax: +41 (0) [email protected] Technical Services 24/7 global network includes post-sales service and Systems Integration teams» Emergency call out, service contracts, on/off-site repair, training and commissioning» Complete range of spares, consumables and accessories Asia Pacific Honeywell Analytics Asia Pacific #508, Kolon Science Valley (I) Guro-Dong, Guro-Gu Seoul, Korea Tel: +82 (0) Fax: +82 (0) [email protected] Please Note: While every effort has been made to ensure accuracy in this publication, no responsibility can be accepted for errors or omissions. Data may change, as well as legislation, and you are strongly advised to obtain copies of the most recently issued regulations, standards, and guidelines. This publication is not intended to form the basis of a contract. H_System57_BR0102_V3 2/ Honeywell Analytics HWA6038
2 An advanced world of intelligent gas detection system management
3 A world of control technology High precision, intelligent control Master/voted alarm options High packing density Flexible I/O configuration Relay output options System 57 - the heart of fire and gas control For almost half a century, Sieger gas detection systems have provided the safety needed to protect plant and personnel from flammable and toxic gas hazards. Across the globe, they are installed in a wide variety of applications ranging from simple small scale systems to some of the world s largest fully integrated fire and gas detection systems. To fulfill the unique requirements of each individual application requires a control system with unlimited flexibility. The modular design approach employed by the Sieger System 57 enables you to define, in detail, the unique control and alarm parameters to fulfil your requirement. System 57 accepts inputs from flammable and toxic gas detectors, a large range of flame, smoke and heat detectors and manual call points. Available outputs include relays, analog signals and industry standard digital protocols. Packaged in either wall mounting cabinets or panel mounting racks, System 57 can be used stand alone or integrated into the heart of a fire and gas system. Whatever the application, large or small, our sales engineers and customer service representatives are available to discuss your requirements and recommend the control system that s best for you.
4 Technical Summary 5704F Fire Card Specification 5704 Fire Card 5704 Fire Status Panel Audible Sounder - 60dB at 1 meter Remote Facilities accept, reset and silence - Supply Voltage 21V to 32Vdc 18V to 32Vdc Power Consumption 2W 0.75W Operating Temperature -5ºC to +55ºC Storage Temperature -25ºC to +55ºC Operating Humidity 20-90% RH (non condensing) Dimensions 3U high x 25mm wide Weight.4lbs (175g).16lbs (75g) Approvals EN50270 Cabinets Racks and Power Supplies Specification Cabinets Material Mild Steel Color RAL slate grey Hinge Left hand side Lock Right hand side Rack Mounting 8 way: half 19" profile. 16 way: 19" universal profile Pre-formed Gland Entries 8 way: 2 x M25; 2 x PG16; 8 x M20; 6 x PG11 16 way: 3 x M25; 4 x PG16; 16 x M20; 10 x PG11 Environmental Protection IP54 Mounting Plate 8 way: 120mm high x 220mm wide 16 way: 120 mm high x 440mm wide Earth Grounding Points Main Cabinet: M6. Door: M5. Mounting Bracket Holes 10mm diameter Weight 8 way: 22lbs (10.0kg) 16 way: 29.7lbs (13.5kg) Racks Material Galvanized Steel Color (Mounting Brackets) RAL slate grey Mounting 8 way: half 19" profile. 16 way: 19" universal profile Earth Grounding Point M5 stud Mounting Bracket Holes 6mm diameter Supply Voltage 18 to 32Vdc Power Consumption 1.5W Operating Temperature -5ºC to +55ºC Storage Temperature -25ºC to +55ºC Operating Humidity 0-90%RH (non-condensing) Cabinets Racks and Power Supplies Specification cont. Racks cont. Weight 8 way front access 8.5lbs (3.9kg) (inc. Engineering Card & DC input Card) 16 way front access 15lbs (5.8kg) 8 way rear access 6.1lbs (2.8kg) 16 way rear access 9lbs (4.1kg) Approvals EN50270 Power Supplies Supply Voltage ac: 85V to 264V; 47Hz to 440Hz dc: 110V to 340V Inrush Current typically 30A at 230V input for 50W full load Output Voltage 24Vdc ± 10% Power Supply Rating 8-way: 50W upgradeable to 100W 16-way: 50W upgradeable to 200W Overload Protection Operates at more than 105% of rating. Recovery automatic. Overvoltage Protection Operates at more than 115% of rating Mounting 8 way: half 19" profile. 16 way: 19" universal profile Earth Grounding Point M5 stud Mounting Bracket Holes 6mm diameter Operating Temperature -25ºC to +55ºC Operating Humidity 20-90%RH (non-condensing) Weight 8 way,50w 1.9lbs (0.9kg) 16 way, 50W 2.1lbs (0.96kg) subunit: 1.8lbs (815g) 50W module.51lbs (230g) Color Front: RAL slate grey Body: Black anodize Approvals EN50270 Cabinets Racks and Power Supplies Dimension Drawings (rear access) 247 (8 way) 450 (16 way) way way (front access) (8 way) (16 way) (rear access) (front access) 8 way way (8 way) (16 way) 220 * Dimensions in mm
5 Gas Control Card This provides a single channel control function within a 1" wide package. Independent single channel operation Plug-in input and output options Gas Control Card This provides four channels of control function within a 1" wide package. 4-channel operation Choice of output options Channel displayed: automatic sequencing, highest reading, combination or manual channel display selection options f Fire Control Card This provides four zones of fire control within a 1" wide package. 4 zone fire card 2 line monitored outputs Up to 15 cards in a 19" rack fs Fire Status Panel Each rack that contains a 5704F fire card has one 5704FS fire status panel fitted. The 5704FS fire status panel provides common display and alarm indication for all of the fire cards in a rack as well as a local audible sounder. It also provides common push buttons for executing specific fire card related functions. Common fire control card push button functions Common display and alarm indications 5 Master Alarm Update Panel The master alarm update facility can be enhanced by adding the optional master alarm update panel. 1" wide panel Audible and visual alarm Reset and accept push button Provides update facilities without the need for external wiring 6 Power Supply Units The power supply units are rack mounted to complement the System 57 systems 1U high, 19" & 1/2 19" units Upgradeable to 200W in 50W blocks Auto sensing input voltage: AC or DC Regulated DC output Over voltage and overload protected 7 Engineering Card The System 57 engineering card provides full maintenance and set up facilities for each channel card. The front panel has a series of tactile feedback push buttons that allows checks of the alarm levels and performance to be carried out for each channel. A real-time on board clock provides calibration history and calibration overdue reminder functions. Security protected User friendly operation Calibration facility Command accept/abort facility Channel card set up capability Local audible sounder
6 Optional analog output module Catalytic input board Analog input board Blank panel
7 8 Engineering Card Modules A number of plug-in options for the extended system capabilities: 8a Serial Communications Module The serial communications module provides a gateway between the System 57 rack and a remote device (DCS, PLC or SCADA package) to allow the continuous monitoring of each channel s operation and condition as well as allowing remote configuration of the system operation. Industry standard MODBUS RTU protocol RS485/422/232 standard Bi-directional Electrically isolated communications bus SCADA graphics package available 8b Rs232 Printer Driver Module The printer driver module provides a serial output in the event of a gas alarm, fault or user intervention. RS232 ASCII event data Selectable print criteria Time and date stamping Electrically isolated communications bus 8c Master Alarm Update Module The alarm update module provides a common alarm indication with new alarm event update. 2 Outputs: 1 relay, 1 Darlington Selectable operation: pulsed, continuous Alarm accept input Common alarm reset input Complies with ISA M, DIN Optional master alarm update panel 9 Interface Cards There are 9 versions of interface card available (5 for 5701 Gas, 2 for 5704 Gas and 2 for 5704 Fire Control Cards). The interface cards provide the link between the various fire or gas detectors and the control cards. Sensor interface Flexible relay options Individual control card power option High integrity operation option Accepts <_ 2.5mm/14 gauge cable 10 Rack Assemblies System 57 racking units provide mounting options for the system 57 control cards and interface cards. The racks are available complete with a DC input card and an engineering card. 3U high format Front and rear wiring options Half and full 19" versions Up to 64 channels of gas detection or 60 channels of fire detection in a single rack, or a combination of both. Cabinet Assemblies The System 57 cabinets provide a convenient and compact mounting of the rack assemblies and PSUs Wall mounting half and full 19" versions IP54/Nema 12 cabinet protection rating Preformed knock-out gland entries Accessory mounting plate Dc Input Card The DC input card is connected directly to the engineering card and provides the connection point for power supplied to the whole rack. The field wiring from the engineering card modules is also on this card. Common power supply wiring point Reverse polarity and short circuit protection Multi-supply input capability
8 Technical Summary Interface Card Selection Table 5701 Gas Interface Card Type Field Interface Double SPCO Triple SPCO Triple DPCO High Integrity 5704 Gas Interface Card Type 5704F Fire Interface Card Type Quad Relay Relay Interface Hex Relay Relay Interface Sensor Connection No relays 3 SPCO Relays 5 SPCO Relays 8 Changeover Relays 8 Changeover Relays* 4 SPCO Relays** 12 SPCO and 4 SPST Relays** 6 SPCO Relays** 24V in 24V out Analog *** Remote Inhibit Remote Reset Remote Accept, Reset, Silence 2 x line monitored outputs * 8 relays (7 fully configurable, 1 for fault alarm). Configurable master alarm functions or a mixture of master and individual alarms. The relay states are monitored by the control card to ensure correct operation of the relays. ** Fully configurable for individual or master alarms and relay operation. *** With optional analog output module fitted to control card. 5704F Indications Indication Function Colour Continuous Flashing 5704 Fire Card Fire Red Fire condition on zone (accepted) New fire condition (not accepted) Fault Yellow Fault condition on zone (accepted) New fault condition (not accepted) Inhibit Yellow Zone inhibited - Output channel Yellow Output channel in fault condition (accepted) New output fault condition (not accepted) Selected zone Yellow Active when zone has been accepted - Card fault Yellow Card fault (accepted) Card fault (not accepted) Power Green Healthy Fire Status Panel Master fire Red Fire condition on at least one zone (accepted) New fire condition (not accepted) Master fault Yellow Fault condition on at least one zone (accepted) New fault condition (not accepted) Master inhibit Yellow At least one zone inhibited - Master silence Yellow At least one output silenced - Master walk test Yellow At least one zone in walk test mode - Earth fault Yellow Earth fault (accepted) New earth fault (not accepted) Power Green Healthy - Audible Mode Continuous 1s ON, 1s OFF 1s ON every 10s 1s ON every 30s Indication New fire condition (not accepted) New fault condition (not accepted) Fire signal on at least one zone (accepted) Fault signal on at least one zone (accepted)
9 Technical Summary 5701/4 Gas Card Specification Control Card 5701 Control Card 5704 Control Card Back lit LCD Bar graph+peak reading, digital, alphanumeric Bar graph+peak reading, digital, alphanumeric Front Panel Facilities Red LED: A1, A2, A3 CH1-4 LEDs: A1, A2, A3, fault, inhibit per channel Yellow LED: fault, inhibit Attn LED: card fault, update alarm, alarm test Green LED: power Green LED: power Push button: alarm reset/card select Push button: alarm reset/card select Remote Facilities Inhibit and remote alarm reset Inhibit and remote alarm reset Supply Voltage 18V to 32Vdc 18V to 32Vdc Power Consumption Catalytic: 3.75W 4-20mA: 3.25W Catalytic: 12.8W 4-20mA: 8.4W Display/Alarm Point Linearity: 1% fsd Repeatability: 1% fsd Linearity: 2% fsd Repeatability: 2% fsd Electronic Drift Less than 2% / 6 months Less than 3% / 6 months Operating Temperature -5ºC to +55ºC -5ºC to +55ºC Storage Temperature -25ºC to +55ºC -25ºC to +55ºC Operating Humidity 20-90% RH (non condensing) 20-90% RH (non condensing) Dimensions 3U high x 25mm wide 3U high x 25mm wide Weight 165g 165g Approvals EN50270 EN50270 Catalytic Bridge Input Drive Method Constant current Constant current Current Range 70mA to 283mA 90mA to 315mA Full Scale Range 15mV to 600mV 15mV to 300mV Maximum Line Resistance 40 ohms at 250mA (including sensor) 40 ohms at 200mA (including sensor) 4-20mA Input Loop Powered Voltage 23V ± 5% isolated 24V ± 5% isolated Sensor Configuration current sink or source current source Signal Measurement Range 0 to 25mA 0 to 25mA Maximum Loop Resistance 500 ohms (including sensor) 500 ohms (including sensor) Analog Output Option Measurement Signal Range 0 to 20mA or 4 to 20mA 0 to 20mA or 4 to 20mA Linearity From Input Better than 2% fsd Better than 2% fsd Repeatability From Input Better than 1% fsd Better than 1% fsd Configuration Isolated current sink or source (with external supply) Isolated per card for current sink or source (with external supply) Interface Card Specification 5701 Interface Relay Cards 5704 Interface Relay Cards 5704F Interface Relay Cards Relay Contacts 5A at 250Vac/32Vdc (non-inductive) Relay Operation selectable- latching/non-latching, normally energized/ de-energized Power Consumption Field Interface card 0.0W Quad Relay Interface 1.7W Hex Relay Interface 2W Double SPCO card 0.8W Relay Interface Assembly 6.5W Relay Interface Assembly 6.5W Triple SPCO card 1.0W Triple DPCO card 1.6W High Integrity card 1.7W Terminals accepts up to 2.5mm ² (14AWG) cable Operating Temperature -5ºC to +55ºC Storage Temperature -25ºC to +55ºC Operating Humidity 20-99% RH (non condensing) Weight Field Interface card 95g Quad Relay Interface 230g Hex Relay Interface 250g Double SPCO card 155g Relay Interface Assembly 500g Relay Interface Assembly 500g Triple SPCO card 205g Triple DPCO card 245g High Integrity card 255g Approvals EN50270
10 Control Cards The System 57 offers unrivalled flexibility with both Fire and Gas control cards available in the same rack. Gas Control Cards The System 57 gas control cards provide display and alarm facilities for the full range of Sieger gas detectors. Their concise, back lit, multi-part LCD displays the gas reading and status in both analog bar graph and digital numeric forms. In addition, there is an alpha numeric message section to give sensor (and engineering function) status. There is a choice of either the single channel 5701 or the four channel 5704 gas control cards. Each card has two input options; one is for catalytic bridge type while the other is for 4 to 20mA sensors or transmitters. 3 levels of alarm Options of individual, zoned, voted, master, time delayed, update and rate of rise alarm facilities Clear 4 part LCD display Peak reading facility Sensor performance monitoring Fire Control Cards The 5704F Fire control cards provide display and alarm facilities for a wide variety of fire detection products and provides up to four fire zone inputs compatible with most flame, smoke and heat detectors and manual call points. The status of each fire zone is individually displayed by high intensity LEDs. In addition, each card has two line monitored alarm output circuits. Both Fire and Gas control cards can be freely mixed in a rack. High intensity LED indications Up to 60 fire zones per 19" rack Configurable for use with a wide range of fire detection products Oil and Gas Petrochemical Onshore Offshore Industrial Chemical Semi-conductor Water treatment Food Commercial Building services Car parks Boiler houses Single Channel Gas Control Card Four Channel Gas Control Card Four Zone Fire Card Fire Status Panel Engineering Card
Touchpoint Pro. Flexible Gas Control System
Touchpoint Pro Flexible Gas Control System The ideal safety system Honeywell s Touchpoint Pro makes gas control system design, installation, configuration and operation simple. Touchpoint Pro uses a building
Gas Detection. Real-Time visibility on the safety and location of your lone workers So you can protect your people, assets and reputation.
Gas Detection Real-Time visibility on the safety and location of your lone workers So you can protect your people, assets and reputation. No matter how remote their location, lone workers are only a click
JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)
transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control
Electronic Control Devices The European Product Catalogue 2007
FX07 Field Controller (1/4) FX07 Field Controller Display Model Dimensions in mm (inches) The FX07 is a terminal unit controller in the Facility Explorer range of products. The controller is designed specifically
Electronic Control Devices The European Product Catalogue 2007
FX14 Field Controller (1/4) FX14 Field Controller The FX14 is an equipment field controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating,
CB200W Water Leak Detection Panel Application Guide
Checked by: AJC Approved by: JBJ Contents CB200W Water Leak Detection Panel Application Guide 1. Cabinet Specifications... 2 2. Panel Hardware Specifications... 3 3. Panel Configuration... 4 4. Technical
(68.52) X. June 2000 Supercedes February 2000. xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we look @ business differently
(68.52) X June 2000 Supercedes February 2000 xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM.... we look @ business differently XENEX SYSTEM ARCHITECTURE Note: This schematic is for guidance only please
LeakFilm. Protecting your high-tech assets with innovative, user-friendly technology for liquid leak detection
LeakFilm Protecting your high-tech assets with innovative, user-friendly technology for liquid leak detection LeakFilm The most reliable, durable, cost-effective solution Unlike some other forms of liquid
PolyGard Carbon Monoxide CO Transmitter ADTX3 1110
PolyGard Carbon Monoxide CO Transmitter ADTX3 1110 DESCRIPTION CO transmitter including digital measurement value processing and temperature compensation for the continuous monitoring of the ambient air
Buckeye Detection Systems Fixed Detection Systems Application Survey
Buckeye Detection Systems Fixed Detection Systems Application Survey Channel Partner Representative : Company Name: Representative: BDS Representative: Client Contact Information : Company Name: Company
Sieger Searchpoint Optima Plus
Sieger Searchpoint Optima Plus Advanced infrared point gas detector Sieger Searchpoint Optima Plus Why Searchpoint Optima Plus is the right choice... The proven strengths of the original Searchpoint OPTIMA
Process Alarm Solutions
Process Alarm Solutions Reliable Supervision and Control www.selco.com SELCO flexible alarm panels for supervision and control SELCO provides efficient and reliable solutions for alarm monitoring of electrical
VEGA Analogue Addressable Control Panels
Analogue Addressable Control Panels Representing the future of fire alarm control technology, Vega's modular concept enables the tailoring of system design for the smallest to the largest system. Designed
Model: DC-A2IO Advanced HVAC Controller
Model: DC-A2IO Advanced HVAC Controller Job Name: Schedule Reference: Date: DC-A2IO Advanced HVAC Controller Package PAC-IF01 M-Net Adapter AL2-14MR-D α2 Simple Application Controller Accessories AL2-2DA
TrueAlarm Fire Alarm Systems
TrueAlarm Systems UL, ULC, CSFM Listed; FM Approved* Network Annunciators; es Features Provides a dedicated local area network (LAN) for connection of a TrueSite workstation server to remote clients: es
THYRISTORS T1-1PH from 850A to 2700A Specifications Universal 1 Phase Thyristor Unit 55-77-03-62, March 2012
Technical Information THYRISTORS T1-1PH from 850A to 2700A Specifications Universal 1 Phase Thyristor Unit 55-77-03-62, March 2012 GENERAL DESCRIPTION THYRISTORS T1-1PH is a full digital and universal
TMS TANK MANAGEMENT SYSTEM
TMS TANK MANAGEMENT SYSTEM Page 1 of 9 Operating Instructions GENERAL The Tank Management System is a bespoke design to control, monitor and accommodate efficient storage and dispensing of TMS. FUNCTIONS
Measurement. SITRANS F US Inline. Transmitter FUS080/FUE080 4/219
Siemens AG 2010 Flow Measurement Overview The transmitter is available in an IP67/NEMA X/6 enclosure and is designed for use in the flowmeters series: SONOKIT (1- or 2-track) FUS380 (2-track) FUE380 (2-track)
PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS
PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS FRANCE Head office USA 4 Rue du Bois Chêne le loup Parc d Activité de Brabois 54 500 VANDOEUVRE LES NANCY (33) 0383442413, Fax (33) 0383443797
FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10
TECHNICAL SPECIFICATIONS Page 1 of 10 FIRE DETECTION AND ALARM SYSTEM Scope Furnish a complete 24V DC conventional, electrically supervised, zone annunciated, fire detection and alarm system as specified
WATER LEAK DETECTION SYSTEM WLDS-10 INSTALLATION & COMMISSIONING
WATER LEAK DETECTION SYSTEM WLDS-10 INSTALLATION & COMMISSIONING DESCRIPTION: An electronic control panel used in conjunction with one pulse meter (water meter with pulse output proportional to flow rate)
Short Form Catalogue. Alarm Systems. Reliable Supervision and Control
Short Form Catalogue Alarm Systems Reliable Supervision and Control Alarm Monitors and Indicators The SELCO product range includes a number of alarm monitors and indicator panels for use in numerous applications.
Thyristor-controlled power supplies and battery chargers
Thyristor-controlled power supplies and battery chargers Input voltage: 115 / 230 VAC, single phase, 50 / 60 Hz or 208 / 400 / 480 VAC, three phases, 50 / 60 Hz Output voltage: 12 / 24 / 48 / 60 / 72 /
ZC-24DO CANopen I/O Module: 24 Digital Outputs
Z-PC Line EN ZC-24DO CANopen I/O Module: 24 Digital Outputs Installation Manual Contents: - General Specifications - Technical Specifications - Installation Rules - Electrical connections - DIP-switches
www.klmtechgroup.com TABLE OF CONTENT
Page : 1 of 13 Project Engineering Standard www.klmtechgroup.com KLM Technology #03-12 Block Aronia, Jalan Sri Perkasa 2 Taman Tampoi Utama 81200 Johor Bahru Malaysia TABLE OF CONTENT SCOPE 2 REFERENCES
CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems
CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems EN Security System CM705B CM705B - Universal Expander Module The CM705B universal expander provides a cost effective way
ALARM ANNUNCIATOR ME - 3010 INSTRUCTION MANUAL
ALARM ANNUNCIATOR ME - 3010 INSTRUCTION MANUAL INTRODUCTION... 2.. TECHNICAL DATA... 3 ACCESSORIES... 5. INSTALLATION... 7 OPERATION... 12. TECHNICAL INFORMATION... 13 MAINTENANCE... 14. CONFIGURATIONS...
Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D
7000/7000C/7020 Multi-instrument 4921210109D Features Measurements All 3-phase AC measurements True RMS Replaces analogue meters Demand on each phase current Accuracy U, I and F class 0.5 Other values
WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK
WEA-Base User manual for load cell transmitters 1 Contents 1. Technical data... 3 2. Assembly... 4 2.1 Power supply... 4 2.2 Load cells... 4 2.3 RS-485... 4 2.4 Relays... 5 2.5 Digital input... 5 2.6 Analogue
BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell
Data, installation, operation and maintenance 4 & 8 Zone Fire Panels Zircon range BARDIC by Honeywell LED flashing LED Continuous FAULT DISABLE/TEST Power General Fault Sounder Fault/ Disable System Fault
How To Use A Ds340 (Dsp)
Ideal for monitoring dust levels in the exhaust gas of industrial combustion or air filtration processes. Innovative Dynamic Detection Principle (DDP) measurement technique Immune to gradual reductions
FIREDEX 2200. Conventional Fire Panels
68 Flexible, high specification system Choice of 1, 2, 4 or 8 zones Simple one-shot auto-reset user test facility Approved to EN54 Maintenance free poly switch circuit protection, with auto reset Class
WD-AMX Water Detection Controllers
Page 1 of 5 WD-AMX Water Detection Controllers Features: Benefit: LED Status of leak status VFC output Audible alarm Auto or manual reset alarm output Uses an isolated AC signal which prevents oxidation
Q U A D S C A N I I GENERAL User Interface Enclosure Display QUADSCAN II Temperature Range RECEIVER DISPLAY Sensor Weight Optional Relay Enclosure
QUADSCAN II SERIES 7400 ONE TO FOUR CHANNEL RECEIVER QUADSCAN II SERIES 7400 ONE TO FOUR CHANNEL RECEIVER Centralizes Monitoring and Alarming for Gas Transmitters and Fire Detectors. The QuadScan II receiver
Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate
1 919 1919P01 1919P03 QBM65/C, QBM75-1U/C Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate QBM751-1/C QBM65/C QBM75/C Highly accurate measurements with calibration
AIS750 Series Alarm Annunciator
Unparallel, modular, multipoint design with Integrated controllers Two Operation Modes (Stand-alone & Serial) All sizes confi gurable up to 440 Alarm Points RS485 / RS232 Serial Communication Manual &
HART HSSD High Sensitivity Smoke Detection
HART HSSD High Sensitivity Smoke Detection The HART High Sensitivity Smoke Detection system (HSSD) is an Aspirating Smoke Detection system (ASD) designed to give very early indication of an incipient
USER GUIDE. Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator. DM Engineering. Version 1.
USER GUIDE Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator Version 1.3 DM Engineering 2174 Chandler St. Camarillo, CA 91345-4611 805-987-7881 800-249-0487
LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL
EPSOLAR LS1024B / LS2024B/ LS3024B Solar Charge Controller USER MANUAL Thank you very much for selecting our product! This manual offers important information and suggestions with respect to installation,
Automation System TROVIS 6400 TROVIS 6493 Compact Controller
Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general
SFC-200 SERIES FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels. Features. Description
SFC-200 SERIES FIRE ALARM CONTROL PANELS SFC-200 Series Fire Alarm Control Panels Description Summit s SFC-200 Series fire alarm control panels consist of six and twelve zone models which are equipped
TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date 01.12.2008 Rev.
TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL Microener - Copyright 2010 FW 2.2 Date 01.12.2008 Rev. 0 1. Generality 3 2. Introduction 3 3. Accessories and Options 3 4. Installation 3 5. Connection
Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION
Modular, Customizable Wire Replacement 128 / 256 Bit AES Encryption Software Selectable RF Transmit Power Software Selectable Over-the-air Data Rate Modbus ASCII /RTU Compatible Wide Operating Temperature
Quick Connect. quick - simple - efficient. www.g-mw.de
Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power
Duct Humidity Transmitter
SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers
Conventional Fire Detection and Extinguishant Control System Specification
Conventional Fire Detection and Extinguishant Control System Specification Page 1 of 9 Scope Furnish a complete 24VDC Conventional, electrically supervised, combined fire detection and extinguishant release
Analogue addressable devices
Discovery Analogue addressable devices from Channel Safety Systems Discovery Analogue addressable devices Discovery is a range of high-specification, intelligent fire detectors that are developed to meet
Repeaters and Mimics Data Sheet
Repeaters and Mimics Data Sheet IDR series repeaters and mimics allow vital information from a Notifier fire system to be communicated to points around a building remote from the fire alarm control panel.
FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX 759 26-06-2007 759 M1 02 E MES FLOW CALCULATOR 759-02/1
BAMOPHOX 759 E - M FLOW CALCULATOR INSTRUCTION MANUAL MESURES 22, Rue de la Voie des Bans - Z.I. de la Gare - 95100 ARGENTEUIL Tél : (33) 01 30 25 83 20 - Web : www.bamo.fr Fax : (33) 01 34 10 16 05 -
OVR Three-Phase Recloser and PCD Control Style Guide 1VAL264001-SG October 13, 2009 Revision F
OVR Three-Phase Recloser and PCD Control Style Guide 1VAL264001-SG October 13, 2009 Revision F The OVR three-phase recloser style guide aids in the proper selection of your OVR three-phase style number.
T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE
T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE T-Series industrial inclinometers are compact high performance sensors used to determine inclination in roll and pitch axes with excellent precision and
Triple Waveband Infra-Red Flame Detection
Minerva S200PLUS Ex ia Intrinsically Safe & Ex d Flameproof Solar Blind Flame Detectors Triple Waveband Infra-Red Flame Detection Key Features Unrivalled black body rejection over a wide range of source
INTELLIGENT FIRE ALARM CONTROL PANELS. MR-2100/MR-2200 Intelligent Fire Alarm Control Panels MEA. Features. Description
INTELLIGENT FIRE ALARM CONTROL PANELS MR-2100/MR-2200 Intelligent Fire Alarm Control Panels Description MR-2100/MR-2200 Intelligent Fire Alarm Control Panel (shown with optional LED modules) Secutron's
INTRODUCTION. The data provided is for The Standard Products and any variation will be dealt with at the end of this manual.
INTRODUCTION The information provided herein covers the range of products known as the 'Sensor 901' series. The range of equipment is designed to meet the requirements of BS 5839 parts 1 & 4 1988. The
Modular I/O System Analog and Digital Interface Modules
OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part
Unidirectional Transmitter/ Receiver Units Introduction
Unidirectional Transmitter/ Receiver Units Introduction Wireless Input/Output (I/O) connects directly to analog, discrete and pulse transducer signals. The signals are transmitted by radio and either re-created
C E R T I F I C AT I O N LPCB B O A R D P R E V E N T L O S S. Cooper Fire Systems
P R E V E N T L O S S I O N C E R T I F I C AT LPCB B O A R D I O N Cooper Fire Systems ONE COOPER Every day, thousands of people all over the world use products made by Cooper Industries. As a premier
Y7230A CO 2 Alarm System
Y7230A CO 2 Alarm System FOR CO 2 GAS DETECTION PRODUCT DATA FEATURES APPLICATION Y7230A CO 2 alarm system is used to detect gas leaking from CO 2 beverage dispensing systems and posts an alarm to occupants
Premier M Plus & Infinity 8
25 Years of Manufacturing Excellence Premier M Plus & Infinity 8 Conventional Fire Alarm Systems 007 Assessed to ISO 9001: 2008 Certificate number 330 Premier M Plus 8-24 Zone Conventional Fire Alarm Panel
FLARE MONITORS FLARE MONITOR (FM) PILOT MONITOR (PM) FLAME INTENSITY (FI)
FLARE MONITORS Infrared Sensors for Monitoring Smokeless Flares, Pilots, and Flame Intensity FMDS2014 FLARE MONITOR (FM) Monitor smokeless flare combustion efficiency to maximize destruction of hazardous
A project to optimise quality and energy efficiency must include metering
EMDX 3 : Energy Metering A project to optimise quality and energy efficiency must include metering Metering upstream identifies the critical points and ensures optimum targeting of the actions to be taken,
CSP Combined Series. Telephone Door Entry. with. Proximity Keyfob Access
CSP Combined Series Telephone Door Entry with Proximity Keyfob Access PD-094 Issue 3 General Description The CSP series systems are combined Door Entry Telephone and Proximity Access Systems. The entrance
R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0
FieldBarrier Features Assembly 8... 12 outputs Ex ia IIC, FISCO and Entity Advanced fault isolation and diagnostics at the spur FieldBarrier in Zone 1/Div. 2 Instruments in Zone 0...1/Div. 1 For FOUNDATION
MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE
DESCRIPTION MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE DESCRIPTION The SST Model 5010 Two Channel Smoke/Fire Detection Module provides two independent detection input channels for the NOVA-5000
Engineering Specifications XNX Universal Transmitter
Engineering Specifications XNX Universal Transmitter 1.0 General Description: The XNX Universal Transmitter is a comprehensive solution designed to operate in hazardous locations and utilize sensor technologies
INTELLIGENT FIRE ALARM CONTROL UNITS. MMX-2017-12NDS Intelligent Network Fire Alarm Control Unit. Features. Description
INTELLIGENT FIRE ALARM CONTROL UNITS MMX-2017-12NDS Intelligent Network Fire Alarm Control Unit Description Secutron s MMX-2017-12NDS Network Fire Alarm Control Unit offers modular components to meet a
LDG DTS-4/4R Desktop Coaxial Switch / Remote
LDG DTS-4/4R Desktop Coaxial Switch / Remote LDG Electronics 1445 Parran Road, PO Box 48 St. Leonard MD 20685-2903 USA Phone: 410-586-2177 Fax: 410-586-8475 [email protected] www.ldgelectronics.com
Regards from the Team at Rheology Solutions.
Rheology Solutions is the sole Australian distributor of this product range and we welcome the opportunity of discussing your application requirements. We hope the information you are seeking is contained
IPThermo206G. Offline/online data collector, SMS alarm sender, watchdog terminal for IPThermo Pro network
IPThermo206G Offline/online data collector, SMS alarm sender, watchdog terminal for IPThermo Pro network IPThermo 206G is the central data handling terminal of the IPThermo Pro measurement network. This
EX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL
PRODUCT NAME: CP/PB -150- EXPLOSION-PROOF-MANUAL CALL POINT/ PUSH BOTTON DOC NO.: EX-TECH SAS-12-CP-PB150-TM REV01 EXPLOSION-PROOF MANUAL CALL POINT/ PUSH BOTTON II 2GD EPL Gb, Db Ex d IIC T6, IP66 Ex
40.3. Control Relays and Timers
.3 Contents EASY500/700/800 Intelligent Relays........ EASY/MFD Expansion Modules............ MFD Intelligent Relays................... EASY/MFD Communication Modules....... EASY/MFD Power Supplies, Accessories
Introduction. Refrigerant Leak Detecting System. Feature and Benefits
PSC European Refrigeration Controls Catalogue Catalog Section 9 Product Bulletin PD-GAS-E Refrigerant Leak Detecting System Introduction This range of refrigerant leak detecting systems is designed for
Input signal Maximum Range Accuracy. Thermocouple E -50 to 700 C (-58 to 1832 F) ±1 C
F4 Process Controller Installation and Operation Guide SAFETY ALERTS The symbols below are used on the equipment and throughout this document to draw the user s attention to important operational and safety
Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800
Power-monitoring unit PowerLogic System Technical data sheet 2003 Power Meter Series 800 Function and characteristics PB100313 The PowerLogic Power Meter Series 800 offers all the high-performance measurement
MLC 9000+ TM Maximum Productivity and Versatility for Control without Compromise!
Data Sheet Maximum Productivity and Versatility for Control without Compromise! Basic Bus Communication Module DESCRIPTION The Basic Bus Communication Module (BCM) is part of the MLC 9000+ DIN rail mount
Multipoint Scanning Alarm System
Multipoint Scanning Alarm System Many gas detection applications require multiple sensing locations to provide adequate area protection for plant personnel. Signals from a variety of field measurement
UFGS-28 33 00.00 40 (February 2011) UNIFIED FACILITIES GUIDE SPECIFICATIONS
USACE / NAVFAC / AFCEC / NASA UFGS-28 33 00.00 40 (February 2014) ----------------------------------- Preparing Activity: NASA Superseding UFGS-28 33 00.00 40 (February 2011) UNIFIED FACILITIES GUIDE SPECIFICATIONS
Multi-Range Programmable DC Power Supplies 9115 Series
Data Sheet 1200 W Multi-Range DC Power Supplies Features & Benefits Any 9115 series model can replace several supplies on your bench or in your rack. Unlike conventional supplies with fixed output ratings,
MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features
Central 48 V DC Power Supplies for PoE-Components MICROSENS Description Active network equipment which is supporting the Power-over-Ethernet functions, typically requires a powerful 48 V DC power supply.
MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)
MILLENIUM Table of contents 1. INTRODUCTION 1 2. HARDWARE DESCRIPTION 2 3. INSTALLATION 5 4. CONNECTION 6 5. USER SAFETY AND PROTECTION OF EQUIPMENT 8 1. Introduction The MILLENIUM series has been designed
red-y smart series product information Thermal Mass Flow Meters and Controllers for Gases
red-y smart series product information Thermal Mass Flow Meters and Controllers for Gases Reliable and accurate: Thermal Mass Flow Meters and Controllers Reliable technology and industry standard interfaces
IntesisBox KNX LG Air Conditioning
IntesisBox KNX LG Air Conditioning Gateway for integration of LG Air Conditioners with KNX control systems. 1. Main Features Direct connection to KNX TP-1 (EIB) bus. Direct connection to LG outdoor unit
REGULINE 600VA / 1000VA REGULATOR USER MANUAL
REGULINE 600VA / 1000VA REGULATOR USER MANUAL TUNÇMATİK REGULINE SERIES AUTOMATIC VOLTAGE REGULATOR Models: REGULINE 600VA / REGULINE 1000VA Principle of Operation Automatic Voltage Regulators regulate
Rosemount 333 HART Tri-Loop
Product Data Sheet Rosemount 333 Rosemount 333 HART Tri-Loop HART-TO-ANALOG SIGNAL CONVERTER Convert a digital HART signal into three additional analog signals Easy to configure and install Accessory product
25 Years of Manufacturing Excellence. Premier Quatro Addressable Fire Alarm System. Assessed to ISO 9001: 2008
Premier Quatro Addressable Fire Alarm System Premier Quatro 4 Loop Analogue Addressable Fire Alarm Panel The Premier Quatro is the new 4 loop analogue Alarm Systems. It is available in 1, 2, 3 or 4 loop
VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421
VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421 TABLE OF CONTENTS 1. FEATURES... 1 2. SPECIFICATIONS... 1 2-1 General Specifications...1 2-2 Electrical Specifications... 2 3. FRONT PANEL DESCRIPTION... 4 3-1
ALARMLINE ANALOGUE Linear Heat Detection System
ALARMLINE ANALOGUE Alarmline Analogue sensor cable senses temperature variations by continuously monitoring the resistance of specially doped N.T.C. polymeric insulation. A change in temperature produces
API Marine. BMS Presentation. Ballast Measurement Systems
API Marine BMS Presentation Ballast Measurement Systems BMS4 Typical Configuration BMS4 Typical Configuration BMS4 Extended Configuration BMS4 System (24 tanks) Air regulator Terminal block Drain/Air Filter
OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE
OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE Scaletron Industries, Ltd. Bedminster Industrial Park 53 Apple Tree Lane P.O. Box 365 Plumsteadville, PA 18949 USA Toll Free: 1-800-257-5911 (USA &
RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05
RI-215A Operator s Manual Part Number: 71-0045RK Revision 0 Released: 10/3/05 Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by us to be free from defects in materials and workmanship,
USB-500/600 Series Low-Cost Data Loggers and Accessories
Low-Cost Data Loggers and Accessories Features Stand-alone, remote data loggers and portable logger assistant Measure temperature, humidity, voltage, current, or event/state change 1 or 2 channels Low
HONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions 800-09617V1 Rev A 11/12)
HONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions 800-09617V1 Rev A 11/12) UL864 (Commercial Fire) Compliance General Requirements The VISTA-128FBPT/VISTA250FBPT
DCS Input/Output Relay Card Series
Input/Output Relay Card Series I/O RELAY CARD (with loopback test function) 8N The 8N series I/O Relay Cards easily and quickly standardize and facilitate installation of the relay board. Loopback test
Fire detection equipment
PRODUCT CATALOG Fire detection equipment www.apollo-fire.com Apollo Fire Detectors is one of the world s largest manufacturers of fire detectors, modules and notification devices. Established in 1980,
IntesisBox Modbus Server Fidelio IP
IntesisBox Server Fidelio IP Gateway for integration of Micros Fidelio Ho management system into (RTU and TCP) enabled control systems. Integrate your Micros Fidelio Ho management system into your master
SNMP-1000 Intelligent SNMP/HTTP System Manager Features Introduction Web-enabled, No Driver Needed Powerful yet Easy to Use
SNMP-1000 Intelligent SNMP/HTTP System Manager Features Monitors system fans, temperature, voltage, power supply, CPU fan, CPU temperature, Vcore, watchdog timer etc. Stand alone system monitoring, no
OPERATION MANUAL. Pen type, separate electrode SOIL PH METER Model : PH-220S
Pen type, separate electrode SOIL PH METER Model : PH-220S Your purchase of this SOIL PH METER marks a step forward for you into the field of precision measurement. Although this METER is a complex and
IntesisBox Modbus Server SAMSUNG Air Conditioners
IntesisBox Modbus Server SAMSUNG Air Conditioners Gateway for monitoring and control of Samsung NASA compatible Air Conditioning Systems from any Modbus master device TCP or RTU (BMS, PLC, SCADA, HMI,