Direct Operated Solenoid Valve Metal Seal Series VS 0 Model Number of positions (Single) (Double) ( position) JIS Symbol Model VS0-0 VS0- VS0-0 VS0-0 VS0- VS0-0 VS0-0 VS0- (Closed center) VS0-0 VS0-0 VS0- (Exhaust center) VS0-0 Port size Rc (Nominal size) 8 (A) (8A) (0A) 8 (A) 8 (8A) (0A) 8 (A) 8 (8A) (0A) 8 (A) 8 (8A) (0A) 8 C [dm /(s bar)]..0...0...8...9.0 P A/B b 0. 0.7 0.9 0. 0.7 0.9 0.7 0. 0. 0.8 0. 0. Note ) Min. operating frequency is once every 0 days. (Based on JIS B 875.) Note ) Based on JIS B 875-98. (At the pressure of 0.5 MPa, without surge suppressor) Note ) : From sub-plate Note ) Note ) and Note ) are with controlled clean air. Caution For Safety Instructions and Solenoid Valve Precautions, refer to page --. How to Calculate the Flow Rate For obtaining the flow rate, refer to page - -0. VS Direct operated/metal seal solenoid valve, 5 port valve Type of actuation Single Double position (Closed center) position (Exhaust center) Specifications Solenoid Specifications Flow characteristics Max. () Response operating () () Weight (kg) A/B EA/EB cycle (cpm) time (ms) Cv C [dm /(s bar)] b Cv AC DC AC DC AC DC 0.8 0.9 0.9 0.8 0.9 0.9 0.80.00 0.77 0.9.00...9...9...8.0.5.7 Fluid Operating pressure range Ambient and fluid temperature Manual override 0.7 0.7 0.5 0.7 0.7 0.5 0.5 0. 0. 0.8 0.7 0. 0.80.00 0.80.00 0.8 0.99 0.75 0.8 0.9,00 80,00 80 0 80 0 80 or or 5 or 5 or Air/Inert gas 0 to.0 MPa 0 to 0 C 5 or 0 or 5 or 5 or 0.7 0.8 0.9. 0.98. 0.98. Possible,, DIN terminal, terminal Non-lube Usable with non-lude Lubrication Lubrication Use turbine oil Class (ISO VG), if lubricated. Impact/Vibration resistance (m/s ) 50/50 Note) Manifold Possible Use dry air (Dew point: 0 C or ). If using a lubricant, be sure to use a lubricant for low temperatures. Note) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition. (Values at the initial period) Vibration resistance: No malfunction occurred in a one-sweep test between 5 and 000 Hz. Test was performed at both energized and de-energized states in the axial direction and at the right angles to the main valve and armature. (Values at the initial period) Coil rated voltage Allowable voltage fluctuation Coil insulation type Note) Based on JIS C 00 How to Order 0 Body size: /8 standard Piping 0 ported Port size (Nominal size) Bottom ported 00 Without sub-plate Without sub-plate 0 Rc / 8 (A) (For manifold) Rc / (8A) 0 Rc / 8 (0A) C L Voltage Symbol C T U D 00 VAC, 50/0 Hz 00 VAC, 50/0 Hz 5 VDC 9 Other position Sub-plate Sub-plate 00, 00 VAC, 50/0 Hz; VDC 5 to +0% of rated voltage Class B or equivalent (0 C) Note) with terminal DIN terminal Accessory L P Thread type Nil N T F Rc NPT NPTF Indicator light (DC is possible only for DL.) Manual override -9- VK VZ VF VFR VP VZS VFS VS VQ7 EVS VFN
Series VS 0 Apparent Power (Power Consumption) Apparent power (VA) (Power consumption (W)) AC Inrush Holding 50 Hz 0 Hz 50 Hz 0 Hz 5 VA ( VA ) 5 VA (55 VA ) 7 VA (5./5.5 W) VA (.9/. W) Accessory (). Indicator light (AC) When solenoid gets energized, indicator light illuminates, thus electrical states of the solenoid can be seen from the outside. Power consumption (W) DC 5.5 In the case of position type. Specifications Bottom ported (Sub-plate) Coil rated voltage (0/0 VAC, /00 VDC) Enclosure (Based on JIS C 090) Dustproof Dripproof Sub-plate/ Construction Principle VS0 DIN terminal terminal With rubber plug SC000- SC00- Manual override Non-locking With lock SC000B- SC00B- SC000A- SC00A- Indicate the voltage to be used. Applicable model VS0 VS0 VS0 VS0. Manual override Remove rubber plug at the top of the solenoid cap to install manual override. Push the override with a screwdriver to the required stroke and the valve will shift. With the override in the same position, turn it to the right or left 90 and it will lock. Turn it back 90 to unlock. Caution Be sure to unlock it before energizing the valve electrically. VS0 Description Applicable model Manual override AC PB0 VS0 VS0 (With lock) DC PB0- VS0 Manual override AC PB00 VS0 (Non-locking) DC PB00- In the case of a position solenoid valve, use a non-locking manual override because it has a locking function in the main valve. VS0 (Closed center). Terminal wiring Lead wire from the solenoid is connected to the lower terminal of the terminal block under the junction cover of sub-plate. Connect the lead wire of the power supply corresponding to the solenoid (single solenoid: A side/double solenoid: both A and B sides) to the upper terminal of the terminal block. -9-
Direct Operated Solenoid Valve Metal Seal Series VS 0 Construction VS0 VS0 VK VZ VF VFR VS0/0 VP VZS VFS VS VQ7 EVS VFN Sub-plate Assembly Part No. C: T: terminal U:, D: DIN terminal Mounting bolt and gasket are not included. Part No. for Mounting Bolt and Gasket BG-VS00 VS00-CS- VS00-TS- VS00-S- 0 0 0 0 0 0 Component Parts No. q w e Replacement Parts No. Description Material VS0 VS0 VS0/VS0 r t y Spring Rubber plug for wire Plug for cap Piano wire AXT-9- XT00-0 AXT- XT0- AXT- AXT-- XT0- AXT- u Rubber plug AXT- AXT- AXT- i Mounting bolt Carbon steel AXT-7 AXT-7 AXT-7 o Mounting screw Carbon steel AXT-9 (AXT--) AXT-9 (AXT--) DXT0- (AXT--5)!0 Detent assembly AXT-0! Gasket AXT5-- AXT5-- AXT5--! Gasket AXT- AXT- AXT-! Gasket AXT-5 AXT-5 AXT-5! Gasket AXT-7 ( ): For DC!5 Solenoid Capsule Assembly (With rubber plug) Body Description Sub-plate Spool/Sleeve DIN terminal Specifications / Indicator light (AC only) Indicate the used voltage. Material Aluminum die-casted Aluminum die-casted Stain steel VS0/0 SCA00- SCAD00- SCA00- Note Platinum silver Platinum silver VS0/0 SCA0- SCAD0- SCA0- -9-
Series VS 0 Dimensions (VS0) (VS0) (VS0/0) terminal (VS0) (VS0) (VS0/0) DIN terminal (VS0) (VS0) (VS0/0) Bottom ported (VS0) (VS0) (VS0/0) -9- ( ): DC
5 Series VVS0 Manifold Specifications Specifications Applicable valve Valve stations Accessory VS0/0/0/0 Max. 0 stations () With terminal With interface regulator With stop valve/with flow controls VK terminal Piping Specifications Type Common EXH Configuration P Port size Rc A, B EA, EB, 8 8,, 8 () () () port size G, VZ VF VFR VP VZS Individual EXH, 8 8, 8, () () (Bottom) VFS VS al piping: Individual SUP and different pressure SUP. But it will be the bottom porting specifications. Note) Each port size will be a big size for standard. When the small size is desired, indicate separately. VQ7 How to Order EVS VV S 0 05 SC T VFN Valve Manifold base Applicable valve series S Symbol 0 9 P VS 0 Applicable valve way Applicable valve Base size: 8 Porting specifications A, B Bottom Other EA, EB Valve stations stations Symbol SC SU position Manifold block Manifold specifications Symbol SUP EXH Common Common Common Individual Individual Common Individual Individual 5 Dissimilar pressure Common Dissimilar pressure Individual Thread type Nil Rc N NPT T NPTF F Accessory T With terminal S With stop valve R With throttle valve only. Caution 05 0 5 stations 0 stations. SUP port and EXH port are positioned on both sides of manifold block. Air can be supplied from either side; however, the unused port must be plugged in this case. When operating or more valve stations within a manifold at the same time, take SUP air pressure from both sides and open EXH port to the atmosphere. Precautions Be sure to read before handling. For Safety Instructions and Splenoid Valve Precautions, refer to page --. Mounting. When manifolding an exhaust center position valve, use the individual EXH style manifold. (Back pressure may cause actuator to malfunction.) -9-5
Series VVS0 Construction Dimensions ( ) position: Manifold block Replacement Parts: Sub-assembly No. q w e r t y No. u i o Replacement Parts Description Hexagon socket head screw Gasket O-ring Formula/Stations L = 8n + 7 L = 8n + Material Carbon steel Manifold al Parts Assembly Blanking plate Throttle valve spacer Stop valve spacer Interface regulator Block disk Rubber plug Description Assembly part no. AXT-A- 0 0 Manifold block assembly AXT-A- 0 AXT-A- AXT-A-- 0 End plate (U side) assembly AXT-A-- 0 AXT-A-- 0 End plate (D side) assembly AXT-A-- 0 Terminal assembly AXT-5A Junction cover assembly AXT-A- Stations Tie-rod AXT-5- Stations AXT-7A AXT9A AXT95A ARB0-00- AXT- AXT-9 0 0 58 79 9 SC (T only) M x 5 AXT5-- AS58-05 (P port regulation) (A/B port regulation) 5 7 55 7 7 9 0 Formula for manifold weight M = 0.05n + 0.9 (kg) -G, / position: ( ) Formula/Stations L = 8n + 7 L = 8n + 0 0 58 79 9 5 7 55 7 7 9 0 Formula for manifold weight M = 0.5n + 0.9 (kg) ( ): DC -9-